@bentley/substation-physical-schema 1.0.5-dev.1 → 1.0.5

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
@@ -1 +1 @@
1
- {"$schema":"https://dev.bentley.com/json_schemas/ec/32/ecschema","name":"SubstationPhysical","version":"01.00.05","alias":"subphy","label":"SubstationPhysical","description":"This schema contains classes used for Substation Design.","references":[{"name":"BisCore","version":"01.00.26"},{"name":"PowerSystemResourcesPhysical","version":"01.00.01"},{"name":"Terrain","version":"01.00.01"},{"name":"Fasteners","version":"01.00.00"},{"name":"ConstraintSolver","version":"01.00.01"},{"name":"CoreCustomAttributes","version":"01.00.05"},{"name":"BisCustomAttributes","version":"01.00.00"}],"customAttributes":[{"className":"CoreCustomAttributes.ProductionStatus","SupportedUse":"NotForProduction"},{"className":"BisCustomAttributes.SchemaLayerInfo","Value":"Application"}],"items":{"ConstraintType":{"schemaItemType":"Enumeration","type":"int","isStrict":true,"enumerators":[{"name":"Free","value":0,"label":"Free"},{"name":"Fixed","value":1,"label":"Fixed"}]},"PhysicalContainer":{"schemaItemType":"EntityClass","label":"Physical Container","description":"Container for definition-oriented physical elements.","baseClass":"BisCore.DefinitionElement","mixins":["BisCore.ISubModeledElement"]},"PhysicalEquipmentPrimaryPart":{"schemaItemType":"EntityClass","label":"Physical Equipment Primary Part","description":"An psrp:Equipment represents an Electrical Equipment Primary Part when the equipment is placed in a 3D PhysicalModel.","baseClass":"PowerSystemResourcesPhysical.Equipment","properties":[{"name":"PrimaryPartNumber","type":"PrimitiveProperty","label":"Primary Part Number","typeName":"string"},{"name":"PrimaryPartNumberQuantity","type":"PrimitiveProperty","label":"Primary Part Number Quantity","typeName":"int"},{"name":"CodeValue","type":"PrimitiveProperty","label":"Internal Device Id","typeName":"string"}]},"PhysicalEquipmentAdditionalPart":{"schemaItemType":"EntityClass","label":"Physical Equipment Additional Part","description":"An psrp:Equipment represents an Electrical Equipment Additional Part when the equipment is placed in a 3D PhysicalModel.","baseClass":"PowerSystemResourcesPhysical.Equipment","properties":[{"name":"AdditionalPartNumbers","type":"PrimitiveProperty","label":"Additional Part Number","typeName":"string"},{"name":"AdditionalPartNumberQuantity","type":"PrimitiveProperty","label":"Additional Part Number Quantity","typeName":"int"},{"name":"CodeValue","type":"PrimitiveProperty","label":"Internal Device Id","typeName":"string"}]},"PhysicalStructurePrimaryPart":{"schemaItemType":"EntityClass","label":"Physical Structure Primary Part","description":"An psrp:Structure represents an Electrical Structure Primary Part when the Structure is placed in a 3D PhysicalModel.","baseClass":"PowerSystemResourcesPhysical.Structure","properties":[{"name":"PrimaryPartNumber","type":"PrimitiveProperty","label":"Primary Part Number","typeName":"string"},{"name":"PrimaryPartNumberQuantity","type":"PrimitiveProperty","label":"Primary Part Number Quantity","typeName":"int"},{"name":"CodeValue","type":"PrimitiveProperty","label":"Internal Device Id","typeName":"string"}]},"PhysicalStructureAdditionalPart":{"schemaItemType":"EntityClass","label":"Physical Structure Additional Part","description":"An psrp:Structure represents an Electrical Structure Additional Part when the Structure is placed in a 3D PhysicalModel.","baseClass":"PowerSystemResourcesPhysical.Structure","properties":[{"name":"AdditionalPartNumbers","type":"PrimitiveProperty","label":"Additional Part Number","typeName":"string"},{"name":"AdditionalPartNumberQuantity","type":"PrimitiveProperty","label":"Additional Part Number Quantity","typeName":"int"},{"name":"CodeValue","type":"PrimitiveProperty","label":"Internal Device Id","typeName":"string"}]},"PhysicalFoundationPrimaryPart":{"schemaItemType":"EntityClass","label":"Physical Foundation Primary Part","description":"An psrp:Foundation represents an Electrical Foundation Primary Part when the Foundation is placed in a 3D PhysicalModel.","baseClass":"PowerSystemResourcesPhysical.Foundation","properties":[{"name":"PrimaryPartNumber","type":"PrimitiveProperty","label":"Primary Part Number","typeName":"string"},{"name":"PrimaryPartNumberQuantity","type":"PrimitiveProperty","label":"Primary Part Number Quantity","typeName":"int"},{"name":"CodeValue","type":"PrimitiveProperty","label":"Internal Device Id","typeName":"string"}]},"PhysicalFoundationAdditionalPart":{"schemaItemType":"EntityClass","label":"Physical Foundation Additional Part","description":"An psrp:Foundation represents an Electrical Foundation Additional Part when the Foundation is placed in a 3D PhysicalModel.","baseClass":"PowerSystemResourcesPhysical.Foundation","properties":[{"name":"AdditionalPartNumbers","type":"PrimitiveProperty","label":"Additional Part Number","typeName":"string"},{"name":"AdditionalPartNumberQuantity","type":"PrimitiveProperty","label":"Additional Part Number Quantity","typeName":"int"},{"name":"CodeValue","type":"PrimitiveProperty","label":"Internal Device Id","typeName":"string"}]},"PhysicalSubstationPrimaryPart":{"schemaItemType":"EntityClass","label":"Physical Substation Primary Part","description":"An psrp:Substation represents an Electrical Substation Primary Part when the Substation is placed in a 3D PhysicalModel.","baseClass":"SubstationPhysical.Substation","properties":[{"name":"PrimaryPartNumber","type":"PrimitiveProperty","label":"Primary Part Number","typeName":"string"},{"name":"PrimaryPartNumberQuantity","type":"PrimitiveProperty","label":"Primary Part Number Quantity","typeName":"int"},{"name":"CodeValue","type":"PrimitiveProperty","label":"Internal Device Id","typeName":"string"}]},"Substation":{"schemaItemType":"EntityClass","label":"Substation","description":"Substation represents an Substation when the Substation is placed in a 3D PhysicalModel.","baseClass":"BisCore.PhysicalElement"},"PhysicalSubstationAdditionalPart":{"schemaItemType":"EntityClass","label":"Physical Substation Additional Part","description":"An psrp:Substation represents an Electrical Substation Additional Part when the Substation is placed in a 3D PhysicalModel.","baseClass":"SubstationPhysical.Substation","properties":[{"name":"AdditionalPartNumbers","type":"PrimitiveProperty","label":"Additional Part Number","typeName":"string"},{"name":"AdditionalPartNumberQuantity","type":"PrimitiveProperty","label":"Additional Part Number Quantity","typeName":"int"},{"name":"CodeValue","type":"PrimitiveProperty","label":"Internal Device Id","typeName":"string"}]},"ElectricalGeometry3d":{"schemaItemType":"EntityClass","label":"3D Symbol Geometry","description":"Stores the Geometry data associated with one 3D Electrical Symbol. The Geometry is stored as a GeometryStream. Its (0,0,0) represents the insertion point of the Symbol.","baseClass":"BisCore.GraphicalElement3d"},"ElectricalPhysicalRecipe":{"schemaItemType":"EntityClass","label":"Physical Recipe","description":"Represents the Physical, Anchor points and Property Label data associated with an Equipment's Physical (3D) Definition.","modifier":"Sealed","baseClass":"BisCore.TemplateRecipe3d"},"SubstationPhysicalType":{"schemaItemType":"EntityClass","label":"Substation Physical Type","baseClass":"BisCore.PhysicalType"},"SubstationAspect":{"schemaItemType":"EntityClass","label":"Substation Aspect","modifier":"Abstract","baseClass":"BisCore.ElementUniqueAspect"},"SubstationPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Substation Physical Type Aspect","modifier":"Abstract","baseClass":"BisCore.ElementUniqueAspect"},"Terrain":{"schemaItemType":"EntityClass","label":"Terrain","description":"DTM Terrain","baseClass":"Terrain.Terrain"},"Bolt":{"schemaItemType":"EntityClass","label":"Bolt","baseClass":"Fasteners.Bolt"},"Washer":{"schemaItemType":"EntityClass","label":"Washer","baseClass":"Fasteners.Washer"},"Nuts":{"schemaItemType":"EntityClass","label":"Nuts","baseClass":"Fasteners.Nut"},"PhysicalConstraint":{"schemaItemType":"EntityClass","label":"Physical Constraint","description":"Describes a geometry set that is used by the constraint solver engine.","baseClass":"ConstraintSolver.ConstraintGeometryRecord","properties":[{"name":"Type","type":"PrimitiveProperty","description":"","label":"Constraint Type","priority":90,"typeName":"SubstationPhysical.ConstraintType"}]},"ElectricalPortOwnsPhysicalConstraint":{"schemaItemType":"RelationshipClass","description":"Relationship to associate constraint geometry with Electrical Port.","modifier":"Sealed","baseClass":"BisCore.ElementOwnsChildElements","strength":"Embedding","strengthDirection":"Forward","source":{"multiplicity":"(1..1)","roleLabel":"owns","polymorphic":true,"abstractConstraint":"PowerSystemResourcesPhysical.ElectricalPort","constraintClasses":["PowerSystemResourcesPhysical.ElectricalPort"]},"target":{"multiplicity":"(1..*)","roleLabel":"is owned by","polymorphic":true,"abstractConstraint":"SubstationPhysical.PhysicalConstraint","constraintClasses":["SubstationPhysical.PhysicalConstraint"]}},"StructuralPortOwnsPhysicalConstraint":{"schemaItemType":"RelationshipClass","description":"Relationship to associate constraint geometry with Structural Port.","modifier":"Sealed","baseClass":"BisCore.ElementOwnsChildElements","strength":"Embedding","strengthDirection":"Forward","source":{"multiplicity":"(1..1)","roleLabel":"owns","polymorphic":true,"abstractConstraint":"PowerSystemResourcesPhysical.StructuralPort","constraintClasses":["PowerSystemResourcesPhysical.StructuralPort"]},"target":{"multiplicity":"(1..*)","roleLabel":"is owned by","polymorphic":true,"abstractConstraint":"SubstationPhysical.PhysicalConstraint","constraintClasses":["SubstationPhysical.PhysicalConstraint"]}},"LiveMember":{"schemaItemType":"EntityClass","label":"Live Member","baseClass":"BisCore.PhysicalElement"},"GroundMember":{"schemaItemType":"EntityClass","label":"Ground Member","baseClass":"BisCore.PhysicalElement"},"InsulatorMember":{"schemaItemType":"EntityClass","label":"Insulator Member","baseClass":"BisCore.PhysicalElement"},"LiveMemberOwnsElectricalPort":{"schemaItemType":"RelationshipClass","description":"Relationship to associate Electrical Ports with LiveMember.","modifier":"Sealed","baseClass":"BisCore.ElementOwnsChildElements","strength":"Embedding","strengthDirection":"Forward","source":{"multiplicity":"(1..1)","roleLabel":"owns","polymorphic":true,"abstractConstraint":"SubstationPhysical.LiveMember","constraintClasses":["SubstationPhysical.LiveMember"]},"target":{"multiplicity":"(1..*)","roleLabel":"is owned by","polymorphic":true,"abstractConstraint":"PowerSystemResourcesPhysical.ElectricalPort","constraintClasses":["PowerSystemResourcesPhysical.ElectricalPort"]}},"GroundMemberOwnsStructuralPort":{"schemaItemType":"RelationshipClass","description":"Relationship to associate Structural Ports with GroundMember.","modifier":"Sealed","baseClass":"BisCore.ElementOwnsChildElements","strength":"Embedding","strengthDirection":"Forward","source":{"multiplicity":"(1..1)","roleLabel":"owns","polymorphic":true,"abstractConstraint":"SubstationPhysical.GroundMember","constraintClasses":["SubstationPhysical.GroundMember"]},"target":{"multiplicity":"(1..*)","roleLabel":"is owned by","polymorphic":true,"abstractConstraint":"PowerSystemResourcesPhysical.StructuralPort","constraintClasses":["PowerSystemResourcesPhysical.StructuralPort"]}},"OtherAuxiliaryPhysicalType":{"schemaItemType":"EntityClass","label":"Other Auxiliary Physical Type","baseClass":"PowerSystemResourcesPhysical.AuxiliaryEquipmentPhysicalType"},"EMVTPhysicalType":{"schemaItemType":"EntityClass","label":"Electromagnetic Voltage Transformers Physical Type","description":"Electromagnetic Voltage Transformers \r ","baseClass":"PowerSystemResourcesPhysical.PotentialTransformerPhysicalType"},"OVTPhysicalType":{"schemaItemType":"EntityClass","label":"Optical Voltage Transformers Physical Type","description":"Optical Voltage Transformers \r ","baseClass":"PowerSystemResourcesPhysical.PotentialTransformerPhysicalType"},"CCVTPhysicalType":{"schemaItemType":"EntityClass","label":"Capacitive Coupled Voltage Transformer Physical Type","baseClass":"PowerSystemResourcesPhysical.PotentialTransformerPhysicalType"},"CombinedCTVTPhysicalType":{"schemaItemType":"EntityClass","label":"Combined CT/VT Physical Type","baseClass":"PowerSystemResourcesPhysical.SensorPhysicalType"},"OtherAuxiliary":{"schemaItemType":"EntityClass","label":"Other Auxiliary","baseClass":"PowerSystemResourcesPhysical.AuxiliaryEquipment"},"EMVT":{"schemaItemType":"EntityClass","label":"Electromagnetic Voltage Transformers","description":"Electromagnetic Voltage Transformers \r ","baseClass":"PowerSystemResourcesPhysical.PotentialTransformer"},"OVT":{"schemaItemType":"EntityClass","label":"Optical Voltage Transformers","description":"Optical Voltage Transformers \r ","baseClass":"PowerSystemResourcesPhysical.PotentialTransformer"},"CCVT":{"schemaItemType":"EntityClass","label":"Capacitive Coupled Voltage Transformer","baseClass":"PowerSystemResourcesPhysical.PotentialTransformer"},"CombinedCTVT":{"schemaItemType":"EntityClass","label":"Combined CT/VT ","baseClass":"PowerSystemResourcesPhysical.Sensor"},"NeutralGroundingResistorPhysicalType":{"schemaItemType":"EntityClass","label":"Neutral Grounding Resistor Physical Type","baseClass":"PowerSystemResourcesPhysical.GroundingImpedancePhysicalType"},"NeutralGroundingReactorPhysicalType":{"schemaItemType":"EntityClass","label":"Neutral Grounding Reactor Physical Type","description":"The conductor used to connect the non-current-carrying metal parts of equipment, raceways and other enclosures to the system grounded conductor, grounding electrode conductor, or both, at the service equipment or at the source of a separately-derived system","baseClass":"PowerSystemResourcesPhysical.GroundingImpedancePhysicalType"},"NeutralGroundingResistor":{"schemaItemType":"EntityClass","label":"Neutral Grounding Resistor","baseClass":"PowerSystemResourcesPhysical.GroundingImpedance"},"NeutralGroundingReactor":{"schemaItemType":"EntityClass","label":"Neutral Grounding Reactor","description":"The conductor used to connect the non-current-carrying metal parts of equipment, raceways and other enclosures to the system grounded conductor, grounding electrode conductor, or both, at the service equipment or at the source of a separately-derived system","baseClass":"PowerSystemResourcesPhysical.GroundingImpedance"},"PowerTransformer2WindingsPhysicalType":{"schemaItemType":"EntityClass","label":"Power Transformer - 2 Windings Physical Type","baseClass":"PowerSystemResourcesPhysical.PowerTransformerPhysicalType"},"PowerTransformer3WindingsPhysicalType":{"schemaItemType":"EntityClass","label":"Power Transformer - 3 Windings Physical Type","baseClass":"PowerSystemResourcesPhysical.PowerTransformerPhysicalType"},"DistributionTransformerPhysicalType":{"schemaItemType":"EntityClass","label":"Distribution Transformer Physical Type","baseClass":"PowerSystemResourcesPhysical.PowerTransformerPhysicalType"},"GroundingTransformerwithResistorPhysicalType":{"schemaItemType":"EntityClass","label":"Zigzag Grounding Transformer with Resistor Physical Type","baseClass":"PowerSystemResourcesPhysical.PowerTransformerPhysicalType"},"PowerTransformer2Windings":{"schemaItemType":"EntityClass","label":"Power Transformer - 2 Windings","baseClass":"PowerSystemResourcesPhysical.PowerTransformer"},"PowerTransformer3Windings":{"schemaItemType":"EntityClass","label":"Power Transformer - 3 Windings","baseClass":"PowerSystemResourcesPhysical.PowerTransformer"},"DistributionTransformer":{"schemaItemType":"EntityClass","label":"Distribution Transformer","baseClass":"PowerSystemResourcesPhysical.PowerTransformer"},"GroundingTransformerwithResistor":{"schemaItemType":"EntityClass","label":"Zigzag Grounding Transformer with Resistor","baseClass":"PowerSystemResourcesPhysical.PowerTransformer"},"SeriesCapacitorPhysicalType":{"schemaItemType":"EntityClass","label":"Series Capacitor Physical Type","baseClass":"PowerSystemResourcesPhysical.SeriesCompensatorPhysicalType"},"SeriesReactorPhysicalType":{"schemaItemType":"EntityClass","label":"Series Reactor Physical Type","baseClass":"PowerSystemResourcesPhysical.SeriesCompensatorPhysicalType"},"TCSCPhysicalType":{"schemaItemType":"EntityClass","label":"Thyristor-Controlled Series Capacitor Physical Type","baseClass":"PowerSystemResourcesPhysical.SeriesCompensatorPhysicalType"},"SeriesCapacitor":{"schemaItemType":"EntityClass","label":"Series Capacitor","baseClass":"PowerSystemResourcesPhysical.SeriesCompensator"},"SeriesReactor":{"schemaItemType":"EntityClass","label":"Series Reactor","baseClass":"PowerSystemResourcesPhysical.SeriesCompensator"},"TCSC":{"schemaItemType":"EntityClass","label":"Thyristor-Controlled Series Capacitor","baseClass":"PowerSystemResourcesPhysical.SeriesCompensator"},"PowerCablePhysicalType":{"schemaItemType":"EntityClass","label":"Power Cable Physical Type","baseClass":"PowerSystemResourcesPhysical.ConductorPhysicalType"},"InsulatedPowerCablePhysicalType":{"schemaItemType":"EntityClass","label":"Insulated Power Cable Physical Type","baseClass":"PowerSystemResourcesPhysical.ConductorPhysicalType"},"PowerCable":{"schemaItemType":"EntityClass","label":"Power Cable","baseClass":"PowerSystemResourcesPhysical.Conductor"},"InsulatedPowerCable":{"schemaItemType":"EntityClass","label":"Insulated Power Cable","baseClass":"PowerSystemResourcesPhysical.Conductor"},"BushingPhysicalType":{"schemaItemType":"EntityClass","label":"Bushing Physical Type","baseClass":"SubstationPhysical.OtherAuxiliaryPhysicalType"},"LineTunerPhysicalType":{"schemaItemType":"EntityClass","label":"Line Tuner Physical Type","baseClass":"SubstationPhysical.OtherAuxiliaryPhysicalType"},"SurgeCounterPhysicalType":{"schemaItemType":"EntityClass","label":"Surge Counter Physical Type","baseClass":"SubstationPhysical.OtherAuxiliaryPhysicalType"},"GuyStrainInsulatorPhysicalType":{"schemaItemType":"EntityClass","label":"Guy Strain Insulator Physical Type","baseClass":"SubstationPhysical.OtherAuxiliaryPhysicalType"},"ArcHornPhysicalType":{"schemaItemType":"EntityClass","label":"Arc Horn Physical Type","baseClass":"SubstationPhysical.OtherAuxiliaryPhysicalType"},"CoronaRingPhysicalType":{"schemaItemType":"EntityClass","label":"Corona Ring Physical Type","baseClass":"SubstationPhysical.OtherAuxiliaryPhysicalType"},"AnnunciatorPhysicalType":{"schemaItemType":"EntityClass","label":"Annunciator Physical Type","baseClass":"SubstationPhysical.OtherAuxiliaryPhysicalType"},"StatusIndicatorPhysicalType":{"schemaItemType":"EntityClass","label":"Status Indicator Physical Type","baseClass":"SubstationPhysical.OtherAuxiliaryPhysicalType"},"CableClampsPhysicalType":{"schemaItemType":"EntityClass","label":"Cable Clamps Physical Type","baseClass":"PowerSystemResourcesPhysical.ClampPhysicalType"},"BusClampsPhysicalType":{"schemaItemType":"EntityClass","label":"Bus Clamps Physical Type","baseClass":"PowerSystemResourcesPhysical.ClampPhysicalType"},"Bushing":{"schemaItemType":"EntityClass","label":"Bushing","baseClass":"SubstationPhysical.OtherAuxiliary"},"LineTuner":{"schemaItemType":"EntityClass","label":"Line Tuner","baseClass":"SubstationPhysical.OtherAuxiliary"},"SurgeCounter":{"schemaItemType":"EntityClass","label":"Surge Counter","baseClass":"SubstationPhysical.OtherAuxiliary"},"GuyStrainInsulator":{"schemaItemType":"EntityClass","label":"Guy Strain Insulator","baseClass":"SubstationPhysical.OtherAuxiliary"},"ArcHorn":{"schemaItemType":"EntityClass","label":"Arc Horn","baseClass":"SubstationPhysical.OtherAuxiliary"},"CoronaRing":{"schemaItemType":"EntityClass","label":"Corona Ring","baseClass":"SubstationPhysical.OtherAuxiliary"},"Annunciator":{"schemaItemType":"EntityClass","label":"Annunciator","baseClass":"SubstationPhysical.OtherAuxiliary"},"StatusIndicator":{"schemaItemType":"EntityClass","label":"Status Indicator","baseClass":"SubstationPhysical.OtherAuxiliary"},"CableClamps":{"schemaItemType":"EntityClass","label":"Cable Clamps","baseClass":"PowerSystemResourcesPhysical.Clamp"},"BusClamps":{"schemaItemType":"EntityClass","label":"Bus Clamps","baseClass":"PowerSystemResourcesPhysical.Clamp"},"CableConnectorPhysicalType":{"schemaItemType":"EntityClass","label":"Cable Connector Physical Type","baseClass":"PowerSystemResourcesPhysical.JunctionPhysicalType"},"BusConnectorPhysicalType":{"schemaItemType":"EntityClass","label":"Bus Connector Physical Type","baseClass":"PowerSystemResourcesPhysical.JunctionPhysicalType"},"BusAccessoriesPhysicalType":{"schemaItemType":"EntityClass","label":"Bus Accessories Physical Type","baseClass":"PowerSystemResourcesPhysical.ConnectorPhysicalType"},"CableAccessoriesPhysicalType":{"schemaItemType":"EntityClass","label":"Cable Accessories Physical Type","baseClass":"PowerSystemResourcesPhysical.ConnectorPhysicalType"},"LineHardwarePhysicalType":{"schemaItemType":"EntityClass","label":"Line Hardware Physical Type","baseClass":"PowerSystemResourcesPhysical.ConnectorPhysicalType"},"CableConnector":{"schemaItemType":"EntityClass","label":"Cable Connector","baseClass":"PowerSystemResourcesPhysical.Junction"},"BusConnector":{"schemaItemType":"EntityClass","label":"Bus Connector","baseClass":"PowerSystemResourcesPhysical.Junction"},"BusAccessories":{"schemaItemType":"EntityClass","label":"Bus Accessories","baseClass":"PowerSystemResourcesPhysical.Connector"},"CableAccessories":{"schemaItemType":"EntityClass","label":"Cable Accessories","baseClass":"PowerSystemResourcesPhysical.Connector"},"LineHardware":{"schemaItemType":"EntityClass","label":"Line Hardware","baseClass":"PowerSystemResourcesPhysical.Connector"},"VoltageRegulatorPhysicalType":{"schemaItemType":"EntityClass","label":"Voltage Regulator Physical Type","baseClass":"PowerSystemResourcesPhysical.RegulatingConductingEqPhysicalType"},"ShuntCapacitorPhysicalType":{"schemaItemType":"EntityClass","label":"Shunt Capacitor Physical Type","description":"Single capacitor unit used to inject reactive power (positive Q) to improve voltage ","baseClass":"PowerSystemResourcesPhysical.ShuntCompensatorPhysicalType"},"ShuntCapacitorBankPhysicalType":{"schemaItemType":"EntityClass","label":"Shunt Capacitor Bank Physical Type","description":"Group of capacitor units connected in series/parallel; often switchable in steps \r ","baseClass":"PowerSystemResourcesPhysical.ShuntCompensatorPhysicalType"},"ShuntReactorPhysicalType":{"schemaItemType":"EntityClass","label":"Shunt Reactor Physical Type","baseClass":"PowerSystemResourcesPhysical.ShuntCompensatorPhysicalType"},"ShuntReactorBankPhysicalType":{"schemaItemType":"EntityClass","label":"Shunt Reactor Bank Physical Type","baseClass":"PowerSystemResourcesPhysical.ShuntCompensatorPhysicalType"},"RectifierPhysicalType":{"schemaItemType":"EntityClass","label":"Rectifier Physical Type","baseClass":"PowerSystemResourcesPhysical.PowerElectronicsConnectionPhysicalType"},"InverterPhysicalType":{"schemaItemType":"EntityClass","label":"Inverter Physical Type","baseClass":"PowerSystemResourcesPhysical.PowerElectronicsConnectionPhysicalType"},"VoltageRegulator":{"schemaItemType":"EntityClass","label":"Voltage Regulator","baseClass":"PowerSystemResourcesPhysical.RegulatingConductingEq"},"ShuntCapacitor":{"schemaItemType":"EntityClass","label":"Shunt Capacitor","description":"Single capacitor unit used to inject reactive power (positive Q) to improve voltage ","baseClass":"PowerSystemResourcesPhysical.ShuntCompensator"},"ShuntCapacitorBank":{"schemaItemType":"EntityClass","label":"Shunt Capacitor Bank","description":"Group of capacitor units connected in series/parallel; often switchable in steps \r ","baseClass":"PowerSystemResourcesPhysical.ShuntCompensator"},"ShuntReactor":{"schemaItemType":"EntityClass","label":"Shunt Reactor","baseClass":"PowerSystemResourcesPhysical.ShuntCompensator"},"ShuntReactorBank":{"schemaItemType":"EntityClass","label":"Shunt Reactor Bank","baseClass":"PowerSystemResourcesPhysical.ShuntCompensator"},"Rectifier":{"schemaItemType":"EntityClass","label":"Rectifier","baseClass":"PowerSystemResourcesPhysical.PowerElectronicsConnection"},"Inverter":{"schemaItemType":"EntityClass","label":"Inverter","baseClass":"PowerSystemResourcesPhysical.PowerElectronicsConnection"},"GroundingRodPhysicalType":{"schemaItemType":"EntityClass","label":"Grounding Rod Physical Type","baseClass":"PowerSystemResourcesPhysical.GroundPhysicalType"},"GroundingGridPhysicalType":{"schemaItemType":"EntityClass","label":"Grounding Grid Physical Type","baseClass":"PowerSystemResourcesPhysical.GroundPhysicalType"},"GroundingClampsPhysicalType":{"schemaItemType":"EntityClass","label":"Grounding Clamps Physical Type","baseClass":"PowerSystemResourcesPhysical.GroundPhysicalType"},"GroundingAccessoriesPhysicalType":{"schemaItemType":"EntityClass","label":"Grounding Accessories Physical Type","baseClass":"PowerSystemResourcesPhysical.GroundPhysicalType"},"GroundingRod":{"schemaItemType":"EntityClass","label":"Grounding Rod","baseClass":"PowerSystemResourcesPhysical.Ground"},"GroundingGrid":{"schemaItemType":"EntityClass","label":"Grounding Grid","baseClass":"PowerSystemResourcesPhysical.Ground"},"GroundingClamps":{"schemaItemType":"EntityClass","label":"Grounding Clamps","baseClass":"PowerSystemResourcesPhysical.Ground"},"GroundingAccessories":{"schemaItemType":"EntityClass","label":"Grounding Accessories","baseClass":"PowerSystemResourcesPhysical.Ground"},"FastenersPhysicalType":{"schemaItemType":"EntityClass","label":"Fasteners Physical Type","baseClass":"PowerSystemResourcesPhysical.StructurePhysicalType"},"BoltPhysicalType":{"schemaItemType":"EntityClass","label":"Bolt Physical Type","baseClass":"SubstationPhysical.FastenersPhysicalType"},"WasherPhysicalType":{"schemaItemType":"EntityClass","label":"Washer Physical Type","baseClass":"SubstationPhysical.FastenersPhysicalType"},"NutsPhysicalType":{"schemaItemType":"EntityClass","label":"Nuts Physical Type","baseClass":"SubstationPhysical.FastenersPhysicalType"},"ScrewPhysicalType":{"schemaItemType":"EntityClass","label":"Screw Physical Type","baseClass":"SubstationPhysical.FastenersPhysicalType"},"LiftingLugsPhysicalType":{"schemaItemType":"EntityClass","label":"Lifting Lugs Physical Type","baseClass":"SubstationPhysical.FastenersPhysicalType"},"Fasteners":{"schemaItemType":"EntityClass","label":"Fasteners","baseClass":"PowerSystemResourcesPhysical.Structure"},"Screw":{"schemaItemType":"EntityClass","label":"Screw","baseClass":"SubstationPhysical.Fasteners"},"LiftingLugs":{"schemaItemType":"EntityClass","label":"Lifting Lugs","baseClass":"SubstationPhysical.Fasteners"},"SupportsPhysicalType":{"schemaItemType":"EntityClass","label":"Supports Physical Type","baseClass":"PowerSystemResourcesPhysical.StructurePhysicalType"},"BusSupportPhysicalType":{"schemaItemType":"EntityClass","label":"Bus Support Physical Type","baseClass":"SubstationPhysical.SupportsPhysicalType"},"BracketPhysicalType":{"schemaItemType":"EntityClass","label":"Bracket Physical Type","baseClass":"SubstationPhysical.SupportsPhysicalType"},"UboltPhysicalType":{"schemaItemType":"EntityClass","label":"U-Bolt Physical Type","baseClass":"SubstationPhysical.SupportsPhysicalType"},"MountingKitPhysicalType":{"schemaItemType":"EntityClass","label":"Mounting Kit Physical Type","description":"Additional components needed to mount equipment","baseClass":"SubstationPhysical.SupportsPhysicalType"},"Supports":{"schemaItemType":"EntityClass","label":"Supports","baseClass":"PowerSystemResourcesPhysical.Structure"},"BusSupport":{"schemaItemType":"EntityClass","label":"Bus Support","baseClass":"SubstationPhysical.Supports"},"Bracket":{"schemaItemType":"EntityClass","label":"Bracket","baseClass":"SubstationPhysical.Supports"},"Ubolt":{"schemaItemType":"EntityClass","label":"U-Bolt","baseClass":"SubstationPhysical.Supports"},"MountingKit":{"schemaItemType":"EntityClass","label":"Mounting Kit","description":"Additional components needed to mount equipment","baseClass":"SubstationPhysical.Supports"},"PlatformPhysicalType":{"schemaItemType":"EntityClass","label":"Platform Physical Type","baseClass":"PowerSystemResourcesPhysical.FoundationPhysicalType"},"WalkingPlatformPhysicalType":{"schemaItemType":"EntityClass","label":"Walking platform Physical Type","baseClass":"SubstationPhysical.PlatformPhysicalType"},"SwitchOperatorPlatformPhysicalType":{"schemaItemType":"EntityClass","label":"Switch Operator Platform Physical Type","baseClass":"SubstationPhysical.PlatformPhysicalType"},"Platform":{"schemaItemType":"EntityClass","label":"Platform","baseClass":"PowerSystemResourcesPhysical.Foundation"},"WalkingPlatform":{"schemaItemType":"EntityClass","label":"Walking platform","baseClass":"SubstationPhysical.Platform"},"SwitchOperatorPlatform":{"schemaItemType":"EntityClass","label":"Switch Operator Platform","baseClass":"SubstationPhysical.Platform"},"EquipmentFoundationPhysicalType":{"schemaItemType":"EntityClass","label":"Equipment Foundation Physical Type","baseClass":"PowerSystemResourcesPhysical.FoundationPhysicalType"},"EquipmentFoundation":{"schemaItemType":"EntityClass","label":"Equipment Foundation","baseClass":"PowerSystemResourcesPhysical.Foundation"},"StructureFoundationPhysicalType":{"schemaItemType":"EntityClass","label":"Structure Foundation Physical Type","baseClass":"PowerSystemResourcesPhysical.FoundationPhysicalType"},"StructureFoundation":{"schemaItemType":"EntityClass","label":"Structure Foundation","baseClass":"PowerSystemResourcesPhysical.Foundation"},"ElectricalBuildingPhysicalType":{"schemaItemType":"EntityClass","label":"Electrical Building Physical Type","baseClass":"SubstationPhysical.SubstationPhysicalType"},"LVSwitchPhysicalType":{"schemaItemType":"EntityClass","label":"LV Switches Physical Type","baseClass":"SubstationPhysical.ElectricalBuildingPhysicalType"},"AudioVisualDevicePhysicalType":{"schemaItemType":"EntityClass","label":"Audio Visual Device Physical Type","baseClass":"SubstationPhysical.ElectricalBuildingPhysicalType"},"CommunicationDevicePhysicalType":{"schemaItemType":"EntityClass","label":"Communication Device Physical Type","baseClass":"SubstationPhysical.ElectricalBuildingPhysicalType"},"ElectricPanelPhysicalType":{"schemaItemType":"EntityClass","label":"Electric Panel Physical Type","baseClass":"SubstationPhysical.ElectricalBuildingPhysicalType"},"LVBatteryPhysicalType":{"schemaItemType":"EntityClass","label":"Low Voltage Battery Physical Type","description":"A device in which electrical energy is stored and from which energy may be progressively released.","baseClass":"SubstationPhysical.ElectricalBuildingPhysicalType"},"ConditionerDevicePhysicalType":{"schemaItemType":"EntityClass","label":"Conditioner Device Physical Type","description":"used to remove unwanted matter from an electric or electronic signal","baseClass":"SubstationPhysical.ElectricalBuildingPhysicalType"},"ElectricLoadTimeControlPhysicalType":{"schemaItemType":"EntityClass","label":"Electric Load Time Control Physical Type","description":"A device that applies control to the provision or flow of electrical energy over time ","baseClass":"SubstationPhysical.ElectricalBuildingPhysicalType"},"PowerOutletPhysicalType":{"schemaItemType":"EntityClass","label":"Outlet Physical Type","baseClass":"SubstationPhysical.ElectricalBuildingPhysicalType"},"FanPhysicalType":{"schemaItemType":"EntityClass","label":"Fan Physical Type","baseClass":"SubstationPhysical.ElectricalBuildingPhysicalType"},"LightingFixturePhysicalType":{"schemaItemType":"EntityClass","label":"Lighting Fixture Physical Type","baseClass":"SubstationPhysical.ElectricalBuildingPhysicalType"},"PowerBatteryPhysicalType":{"schemaItemType":"EntityClass","label":"Power Battery Physical Type","baseClass":"SubstationPhysical.ElectricalBuildingPhysicalType"},"EnclosurePhysicalType":{"schemaItemType":"EntityClass","label":"Enclosure Physical Type","baseClass":"SubstationPhysical.ElectricalBuildingPhysicalType"},"SolarDevicePhysicalType":{"schemaItemType":"EntityClass","label":"Solar Device Physical Type","baseClass":"SubstationPhysical.ElectricalBuildingPhysicalType"},"ElectricalBuilding":{"schemaItemType":"EntityClass","label":"Electrical Building","baseClass":"SubstationPhysical.Substation"},"CoverPhysicalType":{"schemaItemType":"EntityClass","label":"Cover Physical Type","baseClass":"SubstationPhysical.EnclosurePhysicalType"},"CabinetPhysicalType":{"schemaItemType":"EntityClass","label":"Cabinet Physical Type","baseClass":"SubstationPhysical.EnclosurePhysicalType"},"GasketPhysicalType":{"schemaItemType":"EntityClass","label":"Gasket Physical Type","baseClass":"SubstationPhysical.EnclosurePhysicalType"},"SecondaryCutOutPhysicalType":{"schemaItemType":"EntityClass","label":"Secondary Cut Out Physical Type","baseClass":"SubstationPhysical.EnclosurePhysicalType"},"PanelboardAssemblyPhysicalType":{"schemaItemType":"EntityClass","label":"Panel Board Assembly Physical Type","baseClass":"SubstationPhysical.EnclosurePhysicalType"},"PullBoxPhysicalType":{"schemaItemType":"EntityClass","label":"Pull Box Physical Type","baseClass":"SubstationPhysical.EnclosurePhysicalType"},"JunctionBoxPhysicalType":{"schemaItemType":"EntityClass","label":"Junction Box Physical Type","description":"A point where one or more conducting equipments are connected with zero resistance.","baseClass":"SubstationPhysical.EnclosurePhysicalType"},"OutletBodyPhysicalType":{"schemaItemType":"EntityClass","label":"Outlet Body Physical Type","baseClass":"SubstationPhysical.EnclosurePhysicalType"},"LVSwitch":{"schemaItemType":"EntityClass","label":"LV Switches","baseClass":"SubstationPhysical.ElectricalBuilding"},"AudioVisualDevice":{"schemaItemType":"EntityClass","label":"Audio Visual Device","baseClass":"SubstationPhysical.ElectricalBuilding"},"CommunicationDevice":{"schemaItemType":"EntityClass","label":"Communication Device","baseClass":"SubstationPhysical.ElectricalBuilding"},"ElectricPanel":{"schemaItemType":"EntityClass","label":"Electric Panel","baseClass":"SubstationPhysical.ElectricalBuilding"},"LVBattery":{"schemaItemType":"EntityClass","label":"Low Voltage Battery","description":"A device in which electrical energy is stored and from which energy may be progressively released.","baseClass":"SubstationPhysical.ElectricalBuilding"},"ConditionerDevice":{"schemaItemType":"EntityClass","label":"Conditioner Device","description":"used to remove unwanted matter from an electric or electronic signal","baseClass":"SubstationPhysical.ElectricalBuilding"},"ElectricLoadTimeControl":{"schemaItemType":"EntityClass","label":"Electric Load Time Control","description":"A device that applies control to the provision or flow of electrical energy over time ","baseClass":"SubstationPhysical.ElectricalBuilding"},"PowerOutlet":{"schemaItemType":"EntityClass","label":"Outlet","baseClass":"SubstationPhysical.ElectricalBuilding"},"Fan":{"schemaItemType":"EntityClass","label":"Fan","baseClass":"SubstationPhysical.ElectricalBuilding"},"LightingFixture":{"schemaItemType":"EntityClass","label":"Lighting Fixture","baseClass":"SubstationPhysical.ElectricalBuilding"},"PowerBattery":{"schemaItemType":"EntityClass","label":"Power Battery","baseClass":"SubstationPhysical.ElectricalBuilding"},"Enclosure":{"schemaItemType":"EntityClass","label":"Enclosure","baseClass":"SubstationPhysical.ElectricalBuilding"},"SolarDevice":{"schemaItemType":"EntityClass","label":"Solar Device","baseClass":"SubstationPhysical.ElectricalBuilding"},"RacewayPhysicalType":{"schemaItemType":"EntityClass","label":"Raceway Physical Type","baseClass":"SubstationPhysical.SubstationPhysicalType"},"Cover":{"schemaItemType":"EntityClass","label":"Cover","baseClass":"SubstationPhysical.Enclosure"},"Cabinet":{"schemaItemType":"EntityClass","label":"Cabinet","baseClass":"SubstationPhysical.Enclosure"},"Gasket":{"schemaItemType":"EntityClass","label":"Gasket","baseClass":"SubstationPhysical.Enclosure"},"SecondaryCutOut":{"schemaItemType":"EntityClass","label":"Secondary Cut Out","baseClass":"SubstationPhysical.Enclosure"},"PanelboardAssembly":{"schemaItemType":"EntityClass","label":"Panel Board Assembly","baseClass":"SubstationPhysical.Enclosure"},"PullBox":{"schemaItemType":"EntityClass","label":"Pull Box","baseClass":"SubstationPhysical.Enclosure"},"JunctionBox":{"schemaItemType":"EntityClass","label":"Junction Box","description":"A point where one or more conducting equipments are connected with zero resistance.","baseClass":"SubstationPhysical.Enclosure"},"OutletBody":{"schemaItemType":"EntityClass","label":"Outlet Body","baseClass":"SubstationPhysical.Enclosure"},"CableTrenchPhysicalType":{"schemaItemType":"EntityClass","label":"Cable Trench Physical Type","baseClass":"SubstationPhysical.RacewayPhysicalType"},"DuctbankPhysicalType":{"schemaItemType":"EntityClass","label":"Duct bank Physical Type","baseClass":"SubstationPhysical.RacewayPhysicalType"},"CableTrayPhysicalType":{"schemaItemType":"EntityClass","label":"Cable Tray Physical Type","baseClass":"SubstationPhysical.RacewayPhysicalType"},"CableLadderPhysicalType":{"schemaItemType":"EntityClass","label":"Cable Ladder Physical Type","baseClass":"SubstationPhysical.RacewayPhysicalType"},"CableLadderFittingPhysicalType":{"schemaItemType":"EntityClass","label":"Cable Ladder Fitting Physical Type","baseClass":"SubstationPhysical.RacewayPhysicalType"},"CableTrayFittingsPhysicalType":{"schemaItemType":"EntityClass","label":"Cable Tray Fittings Physical Type","baseClass":"SubstationPhysical.RacewayPhysicalType"},"CableTrayCoverPhysicalType":{"schemaItemType":"EntityClass","label":"Cable Tray Cover Physical Type","baseClass":"SubstationPhysical.RacewayPhysicalType"},"WirewayPhysicalType":{"schemaItemType":"EntityClass","label":"Wireway Physical Type","baseClass":"SubstationPhysical.RacewayPhysicalType"},"ConduitFittingPhysicalType":{"schemaItemType":"EntityClass","label":"Conduit Fittings Physical Type","baseClass":"SubstationPhysical.RacewayPhysicalType"},"ConduitPhysicalType":{"schemaItemType":"EntityClass","label":"Conduit Physical Type","baseClass":"SubstationPhysical.RacewayPhysicalType"},"Raceway":{"schemaItemType":"EntityClass","label":"Raceway","baseClass":"SubstationPhysical.Substation"},"CableTrench":{"schemaItemType":"EntityClass","label":"Cable Trench","baseClass":"SubstationPhysical.Raceway"},"Ductbank":{"schemaItemType":"EntityClass","label":"Duct bank","baseClass":"SubstationPhysical.Raceway"},"CableTray":{"schemaItemType":"EntityClass","label":"Cable Tray","baseClass":"SubstationPhysical.Raceway"},"CableLadder":{"schemaItemType":"EntityClass","label":"Cable Ladder","baseClass":"SubstationPhysical.Raceway"},"CableLadderFitting":{"schemaItemType":"EntityClass","label":"Cable Ladder Fitting","baseClass":"SubstationPhysical.Raceway"},"CableTrayFittings":{"schemaItemType":"EntityClass","label":"Cable Tray Fittings","baseClass":"SubstationPhysical.Raceway"},"CableTrayCover":{"schemaItemType":"EntityClass","label":"Cable Tray Cover","baseClass":"SubstationPhysical.Raceway"},"Wireway":{"schemaItemType":"EntityClass","label":"Wireway","baseClass":"SubstationPhysical.Raceway"},"ConduitFitting":{"schemaItemType":"EntityClass","label":"Conduit Fittings","baseClass":"SubstationPhysical.Raceway"},"Conduit":{"schemaItemType":"EntityClass","label":"Conduit","baseClass":"SubstationPhysical.Raceway"},"MiscellaneousPhysicalType":{"schemaItemType":"EntityClass","label":"Miscellaneous Physical Type","baseClass":"SubstationPhysical.SubstationPhysicalType"},"FencePhysicalType":{"schemaItemType":"EntityClass","label":"Fence Physical Type","baseClass":"SubstationPhysical.MiscellaneousPhysicalType"},"GatePhysicalType":{"schemaItemType":"EntityClass","label":"Gate Physical Type","baseClass":"SubstationPhysical.MiscellaneousPhysicalType"},"ControlBuildingPhysicalType":{"schemaItemType":"EntityClass","label":"Control Building Physical Type","baseClass":"SubstationPhysical.MiscellaneousPhysicalType"},"OilContainmentSystemPhysicalType":{"schemaItemType":"EntityClass","label":"Oil Containment System Physical Type","baseClass":"SubstationPhysical.MiscellaneousPhysicalType"},"PhysicalSafetyBarrierPhysicalType":{"schemaItemType":"EntityClass","label":"Physical Safety Barrier Physical Type","baseClass":"SubstationPhysical.MiscellaneousPhysicalType"},"GeneralHardwarePhysicalType":{"schemaItemType":"EntityClass","label":"General Hardware Physical Type","baseClass":"SubstationPhysical.MiscellaneousPhysicalType"},"NameplatePhysicalType":{"schemaItemType":"EntityClass","label":"Nameplate Physical Type","description":"Mounted on the equipment, and contains most relevant equipment attributes. Can be provided by manufacturer or created by utility using the data from design.","baseClass":"SubstationPhysical.MiscellaneousPhysicalType"},"TerrainPhysicalType":{"schemaItemType":"EntityClass","label":"Terrain Physical Type","description":"DTM Terrain","baseClass":"SubstationPhysical.MiscellaneousPhysicalType"},"Miscellaneous":{"schemaItemType":"EntityClass","label":"Miscellaneous","baseClass":"SubstationPhysical.Substation"},"AnimalGuardPhysicalType":{"schemaItemType":"EntityClass","label":"Animal Guard Physical Type","baseClass":"SubstationPhysical.PhysicalSafetyBarrierPhysicalType"},"FireBarrierPhysicalType":{"schemaItemType":"EntityClass","label":"Fire Barrier Physical Type","baseClass":"SubstationPhysical.PhysicalSafetyBarrierPhysicalType"},"VehicleBarrierPhysicalType":{"schemaItemType":"EntityClass","label":"Vehicle Barrier Physical Type","baseClass":"SubstationPhysical.PhysicalSafetyBarrierPhysicalType"},"Fence":{"schemaItemType":"EntityClass","label":"Fence","baseClass":"SubstationPhysical.Miscellaneous"},"Gate":{"schemaItemType":"EntityClass","label":"Gate","baseClass":"SubstationPhysical.Miscellaneous"},"ControlBuilding":{"schemaItemType":"EntityClass","label":"Control Building","baseClass":"SubstationPhysical.Miscellaneous"},"OilContainmentSystem":{"schemaItemType":"EntityClass","label":"Oil Containment System","baseClass":"SubstationPhysical.Miscellaneous"},"PhysicalSafetyBarrier":{"schemaItemType":"EntityClass","label":"Physical Safety Barrier","baseClass":"SubstationPhysical.Miscellaneous"},"GeneralHardware":{"schemaItemType":"EntityClass","label":"General Hardware","baseClass":"SubstationPhysical.Miscellaneous"},"Nameplate":{"schemaItemType":"EntityClass","label":"Nameplate","description":"Mounted on the equipment, and contains most relevant equipment attributes. Can be provided by manufacturer or created by utility using the data from design.","baseClass":"SubstationPhysical.Miscellaneous"},"BushingAssembly":{"schemaItemType":"EntityClass","label":"Bushing Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"AnimalGuard":{"schemaItemType":"EntityClass","label":"Animal Guard","baseClass":"SubstationPhysical.PhysicalSafetyBarrier"},"FireBarrier":{"schemaItemType":"EntityClass","label":"Fire Barrier","baseClass":"SubstationPhysical.PhysicalSafetyBarrier"},"VehicleBarrier":{"schemaItemType":"EntityClass","label":"Vehicle Barrier","baseClass":"SubstationPhysical.PhysicalSafetyBarrier"},"LineTunerAssembly":{"schemaItemType":"EntityClass","label":"Line Tuner Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"SurgeCounterAssembly":{"schemaItemType":"EntityClass","label":"Surge Counter Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"GuyStrainInsulatorAssembly":{"schemaItemType":"EntityClass","label":"Guy Strain Insulator Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"ArcHornAssembly":{"schemaItemType":"EntityClass","label":"Arc Horn Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"CoronaRingAssembly":{"schemaItemType":"EntityClass","label":"Corona Ring Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"AnnunciatorAssembly":{"schemaItemType":"EntityClass","label":"Annunciator Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"StatusIndicatorAssembly":{"schemaItemType":"EntityClass","label":"Status Indicator Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"EMVTAssembly":{"schemaItemType":"EntityClass","label":"Electromagnetic Voltage Transformers Assembly","description":"Electromagnetic Voltage Transformers \r ","baseClass":"PowerSystemResourcesPhysical.Equipment"},"OVTAssembly":{"schemaItemType":"EntityClass","label":"Optical Voltage Transformers Assembly","description":"Optical Voltage Transformers \r ","baseClass":"PowerSystemResourcesPhysical.Equipment"},"CCVTAssembly":{"schemaItemType":"EntityClass","label":"Capacitive Coupled Voltage Transformer Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"CombinedCTVTAssembly":{"schemaItemType":"EntityClass","label":"Combined CT/VT Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"NeutralGroundingResistorAssembly":{"schemaItemType":"EntityClass","label":"Neutral Grounding Resistor Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"NeutralGroundingReactorAssembly":{"schemaItemType":"EntityClass","label":"Neutral Grounding Reactor Assembly","description":"The conductor used to connect the non-current-carrying metal parts of equipment, raceways and other enclosures to the system grounded conductor, grounding electrode conductor, or both, at the service equipment or at the source of a separately-derived system","baseClass":"PowerSystemResourcesPhysical.Equipment"},"PowerTransformer2WindingsAssembly":{"schemaItemType":"EntityClass","label":"Power Transformer - 2 Windings Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"PowerTransformer3WindingsAssembly":{"schemaItemType":"EntityClass","label":"Power Transformer - 3 Windings Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"DistributionTransformerAssembly":{"schemaItemType":"EntityClass","label":"Distribution Transformer Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"GroundingTransformerwithResistorAssembly":{"schemaItemType":"EntityClass","label":"Zigzag Grounding Transformer with Resistor Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"SeriesCapacitorAssembly":{"schemaItemType":"EntityClass","label":"Series Capacitor Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"SeriesReactorAssembly":{"schemaItemType":"EntityClass","label":"Series Reactor Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"TCSCAssembly":{"schemaItemType":"EntityClass","label":"Thyristor-Controlled Series Capacitor Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"PowerCableAssembly":{"schemaItemType":"EntityClass","label":"Power Cable Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"InsulatedPowerCableAssembly":{"schemaItemType":"EntityClass","label":"Insulated Power Cable Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"CableClampsAssembly":{"schemaItemType":"EntityClass","label":"Cable Clamps Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"BusClampsAssembly":{"schemaItemType":"EntityClass","label":"Bus Clamps Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"CableConnectorAssembly":{"schemaItemType":"EntityClass","label":"Cable Connector Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"BusConnectorAssembly":{"schemaItemType":"EntityClass","label":"Bus Connector Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"BusAccessoriesAssembly":{"schemaItemType":"EntityClass","label":"Bus Accessories Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"CableAccessoriesAssembly":{"schemaItemType":"EntityClass","label":"Cable Accessories Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"LineHardwareAssembly":{"schemaItemType":"EntityClass","label":"Line Hardware Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"VoltageRegulatorAssembly":{"schemaItemType":"EntityClass","label":"Voltage Regulator Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"ShuntCapacitorAssembly":{"schemaItemType":"EntityClass","label":"Shunt Capacitor Assembly","description":"Single capacitor unit used to inject reactive power (positive Q) to improve voltage ","baseClass":"PowerSystemResourcesPhysical.Equipment"},"ShuntCapacitorBankAssembly":{"schemaItemType":"EntityClass","label":"Shunt Capacitor Bank Assembly","description":"Group of capacitor units connected in series/parallel; often switchable in steps \r ","baseClass":"PowerSystemResourcesPhysical.Equipment"},"ShuntReactorAssembly":{"schemaItemType":"EntityClass","label":"Shunt Reactor Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"ShuntReactorBankAssembly":{"schemaItemType":"EntityClass","label":"Shunt Reactor Bank Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"RectifierAssembly":{"schemaItemType":"EntityClass","label":"Rectifier Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"InverterAssembly":{"schemaItemType":"EntityClass","label":"Inverter Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"GroundingRodAssembly":{"schemaItemType":"EntityClass","label":"Grounding Rod Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"GroundingGridAssembly":{"schemaItemType":"EntityClass","label":"Grounding Grid Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"GroundingClampsAssembly":{"schemaItemType":"EntityClass","label":"Grounding Clamps Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"GroundingAccessoriesAssembly":{"schemaItemType":"EntityClass","label":"Grounding Accessories Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"BoltAssembly":{"schemaItemType":"EntityClass","label":"Bolt Assembly","baseClass":"PowerSystemResourcesPhysical.Structure"},"WasherAssembly":{"schemaItemType":"EntityClass","label":"Washer Assembly","baseClass":"PowerSystemResourcesPhysical.Structure"},"NutsAssembly":{"schemaItemType":"EntityClass","label":"Nuts Assembly","baseClass":"PowerSystemResourcesPhysical.Structure"},"ScrewAssembly":{"schemaItemType":"EntityClass","label":"Screw Assembly","baseClass":"PowerSystemResourcesPhysical.Structure"},"LiftingLugsAssembly":{"schemaItemType":"EntityClass","label":"Lifting Lugs Assembly","baseClass":"PowerSystemResourcesPhysical.Structure"},"BusSupportAssembly":{"schemaItemType":"EntityClass","label":"Bus Support Assembly","baseClass":"PowerSystemResourcesPhysical.Structure"},"BracketAssembly":{"schemaItemType":"EntityClass","label":"Bracket Assembly","baseClass":"PowerSystemResourcesPhysical.Structure"},"UboltAssembly":{"schemaItemType":"EntityClass","label":"U-Bolt Assembly","baseClass":"PowerSystemResourcesPhysical.Structure"},"MountingKitAssembly":{"schemaItemType":"EntityClass","label":"Mounting Kit Assembly","description":"Additional components needed to mount equipment","baseClass":"PowerSystemResourcesPhysical.Structure"},"PlatformAssembly":{"schemaItemType":"EntityClass","label":"Platform Assembly","baseClass":"PowerSystemResourcesPhysical.Foundation"},"WalkingPlatformAssembly":{"schemaItemType":"EntityClass","label":"Walking Platform Assembly","baseClass":"PowerSystemResourcesPhysical.Foundation"},"SwitchOperatorPlatformAssembly":{"schemaItemType":"EntityClass","label":"Switch Operator Platform Assembly","baseClass":"PowerSystemResourcesPhysical.Foundation"},"EquipmentFoundationAssembly":{"schemaItemType":"EntityClass","label":"Equipment Foundation Assembly","baseClass":"PowerSystemResourcesPhysical.Foundation"},"StructureFoundationAssembly":{"schemaItemType":"EntityClass","label":"Structure Foundation Assembly","baseClass":"PowerSystemResourcesPhysical.Foundation"},"LVSwitchAssembly":{"schemaItemType":"EntityClass","label":"LV Switches Assembly","baseClass":"SubstationPhysical.Substation"},"AudioVisualDeviceAssembly":{"schemaItemType":"EntityClass","label":"Audio Visual Device Assembly","baseClass":"SubstationPhysical.Substation"},"CommunicationDeviceAssembly":{"schemaItemType":"EntityClass","label":"Communication Device Assembly","baseClass":"SubstationPhysical.Substation"},"ElectricPanelAssembly":{"schemaItemType":"EntityClass","label":"Electric Panel Assembly","baseClass":"SubstationPhysical.Substation"},"LVBatteryAssembly":{"schemaItemType":"EntityClass","label":"Low Voltage Battery Assembly","baseClass":"SubstationPhysical.Substation"},"ConditionerDeviceAssembly":{"schemaItemType":"EntityClass","label":"Conditioner Device Assembly","baseClass":"SubstationPhysical.Substation"},"ElectricLoadTimeControlAssembly":{"schemaItemType":"EntityClass","label":"Electric Load Time Control Assembly","baseClass":"SubstationPhysical.Substation"},"PowerOutletAssembly":{"schemaItemType":"EntityClass","label":"Outlet Assembly","baseClass":"SubstationPhysical.Substation"},"FanAssembly":{"schemaItemType":"EntityClass","label":"Fan Assembly","baseClass":"SubstationPhysical.Substation"},"LightingFixtureAssembly":{"schemaItemType":"EntityClass","label":"Lighting Fixture Assembly","baseClass":"SubstationPhysical.Substation"},"PowerBatteryAssembly":{"schemaItemType":"EntityClass","label":"Power Battery Assembly","baseClass":"SubstationPhysical.Substation"},"CoverAssembly":{"schemaItemType":"EntityClass","label":"Cover Assembly","baseClass":"SubstationPhysical.Substation"},"CabinetAssembly":{"schemaItemType":"EntityClass","label":"Cabinet Assembly","baseClass":"SubstationPhysical.Substation"},"GasketAssembly":{"schemaItemType":"EntityClass","label":"Gasket Assembly","baseClass":"SubstationPhysical.Substation"},"SecondaryCutOutAssembly":{"schemaItemType":"EntityClass","label":"Secondary Cut Out Assembly","baseClass":"SubstationPhysical.Substation"},"PanelboardAssemblyAssembly":{"schemaItemType":"EntityClass","label":"Panel Board Assembly Assembly","baseClass":"SubstationPhysical.Substation"},"PullBoxAssembly":{"schemaItemType":"EntityClass","label":"Pull Box Assembly","baseClass":"SubstationPhysical.Substation"},"JunctionBoxAssembly":{"schemaItemType":"EntityClass","label":"Junction Box Assembly","description":"A point where one or more conducting equipments are connected with zero resistance.","baseClass":"SubstationPhysical.Substation"},"OutletBodyAssembly":{"schemaItemType":"EntityClass","label":"Outlet Body Assembly","baseClass":"SubstationPhysical.Substation"},"SolarDeviceAssembly":{"schemaItemType":"EntityClass","label":"Solar Device Assembly","baseClass":"SubstationPhysical.Substation"},"CableTrenchAssembly":{"schemaItemType":"EntityClass","label":"Cable Trench Assembly","baseClass":"SubstationPhysical.Substation"},"DuctbankAssembly":{"schemaItemType":"EntityClass","label":"Duct bank Assembly","baseClass":"SubstationPhysical.Substation"},"CableTrayAssembly":{"schemaItemType":"EntityClass","label":"Cable Tray Assembly","baseClass":"SubstationPhysical.Substation"},"CableLadderAssembly":{"schemaItemType":"EntityClass","label":"Cable Ladder Assembly","baseClass":"SubstationPhysical.Substation"},"CableLadderFittingAssembly":{"schemaItemType":"EntityClass","label":"Cable Ladder Fitting Assembly","baseClass":"SubstationPhysical.Substation"},"CableTrayFittingsAssembly":{"schemaItemType":"EntityClass","label":"Cable Tray Fittings Assembly","baseClass":"SubstationPhysical.Substation"},"CableTrayCoverAssembly":{"schemaItemType":"EntityClass","label":"Cable Tray Cover Assembly","baseClass":"SubstationPhysical.Substation"},"WirewayAssembly":{"schemaItemType":"EntityClass","label":"Wireway Assembly","baseClass":"SubstationPhysical.Substation"},"ConduitFittingAssembly":{"schemaItemType":"EntityClass","label":"Conduit Fittings Assembly","baseClass":"SubstationPhysical.Substation"},"ConduitAssembly":{"schemaItemType":"EntityClass","label":"Conduit Assembly","baseClass":"SubstationPhysical.Substation"},"FenceAssembly":{"schemaItemType":"EntityClass","label":"Fence Assembly","baseClass":"SubstationPhysical.Substation"},"GateAssembly":{"schemaItemType":"EntityClass","label":"Gate Assembly","baseClass":"SubstationPhysical.Substation"},"ControlBuildingAssembly":{"schemaItemType":"EntityClass","label":"Control Building Assembly","baseClass":"SubstationPhysical.Substation"},"OilContainmentSystemAssembly":{"schemaItemType":"EntityClass","label":"Oil Containment System Assembly","baseClass":"SubstationPhysical.Substation"},"AnimalGuardAssembly":{"schemaItemType":"EntityClass","label":"Animal Guard Assembly","baseClass":"SubstationPhysical.Substation"},"FireBarrierAssembly":{"schemaItemType":"EntityClass","label":"Fire Barrier Assembly","baseClass":"SubstationPhysical.Substation"},"VehicleBarrierAssembly":{"schemaItemType":"EntityClass","label":"Vehicle Barrier Assembly","baseClass":"SubstationPhysical.Substation"},"GeneralHardwareAssembly":{"schemaItemType":"EntityClass","label":"General Hardware Assembly","baseClass":"SubstationPhysical.Substation"},"NameplateAssembly":{"schemaItemType":"EntityClass","label":"Nameplate Assembly","baseClass":"SubstationPhysical.Substation"},"TerrainAssembly":{"schemaItemType":"EntityClass","label":"Terrain Assembly","baseClass":"SubstationPhysical.Substation"}}}
1
+ {"$schema":"https://dev.bentley.com/json_schemas/ec/32/ecschema","name":"SubstationPhysical","version":"01.00.05","alias":"subphy","label":"SubstationPhysical","description":"This schema contains classes used for Substation Design.","references":[{"name":"BisCore","version":"01.00.25"},{"name":"PowerSystemResourcesPhysical","version":"01.00.01"},{"name":"Terrain","version":"01.00.00"},{"name":"Fasteners","version":"01.00.00"},{"name":"ConstraintSolver","version":"01.00.01"},{"name":"CoreCustomAttributes","version":"01.00.04"},{"name":"BisCustomAttributes","version":"01.00.00"}],"customAttributes":[{"className":"CoreCustomAttributes.ProductionStatus","SupportedUse":"FieldTesting"},{"className":"BisCustomAttributes.SchemaLayerInfo","Value":"Application"}],"items":{"ConstraintType":{"schemaItemType":"Enumeration","type":"int","isStrict":true,"enumerators":[{"name":"Free","value":0,"label":"Free"},{"name":"Fixed","value":1,"label":"Fixed"}]},"PhysicalContainer":{"schemaItemType":"EntityClass","label":"Physical Container","description":"Container for definition-oriented physical elements.","baseClass":"BisCore.DefinitionElement","mixins":["BisCore.ISubModeledElement"]},"PhysicalEquipmentPrimaryPart":{"schemaItemType":"EntityClass","label":"Physical Equipment Primary Part","description":"An psrp:Equipment represents an Electrical Equipment Primary Part when the equipment is placed in a 3D PhysicalModel.","baseClass":"PowerSystemResourcesPhysical.Equipment","properties":[{"name":"PrimaryPartNumber","type":"PrimitiveProperty","label":"Primary Part Number","typeName":"string"},{"name":"PrimaryPartNumberQuantity","type":"PrimitiveProperty","label":"Primary Part Number Quantity","typeName":"int"},{"name":"CodeValue","type":"PrimitiveProperty","label":"Internal Device Id","typeName":"string"}]},"PhysicalEquipmentAdditionalPart":{"schemaItemType":"EntityClass","label":"Physical Equipment Additional Part","description":"An psrp:Equipment represents an Electrical Equipment Additional Part when the equipment is placed in a 3D PhysicalModel.","baseClass":"PowerSystemResourcesPhysical.Equipment","properties":[{"name":"AdditionalPartNumbers","type":"PrimitiveProperty","label":"Additional Part Number","typeName":"string"},{"name":"AdditionalPartNumberQuantity","type":"PrimitiveProperty","label":"Additional Part Number Quantity","typeName":"int"},{"name":"CodeValue","type":"PrimitiveProperty","label":"Internal Device Id","typeName":"string"}]},"PhysicalStructurePrimaryPart":{"schemaItemType":"EntityClass","label":"Physical Structure Primary Part","description":"An psrp:Structure represents an Electrical Structure Primary Part when the Structure is placed in a 3D PhysicalModel.","baseClass":"PowerSystemResourcesPhysical.Structure","properties":[{"name":"PrimaryPartNumber","type":"PrimitiveProperty","label":"Primary Part Number","typeName":"string"},{"name":"PrimaryPartNumberQuantity","type":"PrimitiveProperty","label":"Primary Part Number Quantity","typeName":"int"},{"name":"CodeValue","type":"PrimitiveProperty","label":"Internal Device Id","typeName":"string"}]},"PhysicalStructureAdditionalPart":{"schemaItemType":"EntityClass","label":"Physical Structure Additional Part","description":"An psrp:Structure represents an Electrical Structure Additional Part when the Structure is placed in a 3D PhysicalModel.","baseClass":"PowerSystemResourcesPhysical.Structure","properties":[{"name":"AdditionalPartNumbers","type":"PrimitiveProperty","label":"Additional Part Number","typeName":"string"},{"name":"AdditionalPartNumberQuantity","type":"PrimitiveProperty","label":"Additional Part Number Quantity","typeName":"int"},{"name":"CodeValue","type":"PrimitiveProperty","label":"Internal Device Id","typeName":"string"}]},"PhysicalFoundationPrimaryPart":{"schemaItemType":"EntityClass","label":"Physical Foundation Primary Part","description":"An psrp:Foundation represents an Electrical Foundation Primary Part when the Foundation is placed in a 3D PhysicalModel.","baseClass":"PowerSystemResourcesPhysical.Foundation","properties":[{"name":"PrimaryPartNumber","type":"PrimitiveProperty","label":"Primary Part Number","typeName":"string"},{"name":"PrimaryPartNumberQuantity","type":"PrimitiveProperty","label":"Primary Part Number Quantity","typeName":"int"},{"name":"CodeValue","type":"PrimitiveProperty","label":"Internal Device Id","typeName":"string"}]},"PhysicalFoundationAdditionalPart":{"schemaItemType":"EntityClass","label":"Physical Foundation Additional Part","description":"An psrp:Foundation represents an Electrical Foundation Additional Part when the Foundation is placed in a 3D PhysicalModel.","baseClass":"PowerSystemResourcesPhysical.Foundation","properties":[{"name":"AdditionalPartNumbers","type":"PrimitiveProperty","label":"Additional Part Number","typeName":"string"},{"name":"AdditionalPartNumberQuantity","type":"PrimitiveProperty","label":"Additional Part Number Quantity","typeName":"int"},{"name":"CodeValue","type":"PrimitiveProperty","label":"Internal Device Id","typeName":"string"}]},"PhysicalSubstationPrimaryPart":{"schemaItemType":"EntityClass","label":"Physical Substation Primary Part","description":"An psrp:Substation represents an Electrical Substation Primary Part when the Substation is placed in a 3D PhysicalModel.","baseClass":"SubstationPhysical.Substation","properties":[{"name":"PrimaryPartNumber","type":"PrimitiveProperty","label":"Primary Part Number","typeName":"string"},{"name":"PrimaryPartNumberQuantity","type":"PrimitiveProperty","label":"Primary Part Number Quantity","typeName":"int"},{"name":"CodeValue","type":"PrimitiveProperty","label":"Internal Device Id","typeName":"string"}]},"Substation":{"schemaItemType":"EntityClass","label":"Substation","description":"Substation represents an Substation when the Substation is placed in a 3D PhysicalModel.","baseClass":"BisCore.PhysicalElement"},"PhysicalSubstationAdditionalPart":{"schemaItemType":"EntityClass","label":"Physical Substation Additional Part","description":"An psrp:Substation represents an Electrical Substation Additional Part when the Substation is placed in a 3D PhysicalModel.","baseClass":"SubstationPhysical.Substation","properties":[{"name":"AdditionalPartNumbers","type":"PrimitiveProperty","label":"Additional Part Number","typeName":"string"},{"name":"AdditionalPartNumberQuantity","type":"PrimitiveProperty","label":"Additional Part Number Quantity","typeName":"int"},{"name":"CodeValue","type":"PrimitiveProperty","label":"Internal Device Id","typeName":"string"}]},"ElectricalGeometry3d":{"schemaItemType":"EntityClass","label":"3D Symbol Geometry","description":"Stores the Geometry data associated with one 3D Electrical Symbol. The Geometry is stored as a GeometryStream. Its (0,0,0) represents the insertion point of the Symbol.","baseClass":"BisCore.GraphicalElement3d"},"ElectricalPhysicalRecipe":{"schemaItemType":"EntityClass","label":"Physical Recipe","description":"Represents the Physical, Anchor points and Property Label data associated with an Equipment's Physical (3D) Definition.","modifier":"Sealed","baseClass":"BisCore.TemplateRecipe3d"},"SubstationPhysicalType":{"schemaItemType":"EntityClass","label":"Substation Physical Type","baseClass":"BisCore.PhysicalType"},"SubstationAspect":{"schemaItemType":"EntityClass","label":"Substation Aspect","modifier":"Abstract","baseClass":"BisCore.ElementUniqueAspect"},"SubstationPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Substation Physical Type Aspect","modifier":"Abstract","baseClass":"BisCore.ElementUniqueAspect"},"Terrain":{"schemaItemType":"EntityClass","label":"Terrain","description":"DTM Terrain","baseClass":"Terrain.Terrain"},"Bolt":{"schemaItemType":"EntityClass","label":"Bolt","baseClass":"Fasteners.Bolt"},"Washer":{"schemaItemType":"EntityClass","label":"Washer","baseClass":"Fasteners.Washer"},"Nuts":{"schemaItemType":"EntityClass","label":"Nuts","baseClass":"Fasteners.Nut"},"PhysicalConstraint":{"schemaItemType":"EntityClass","label":"Physical Constraint","description":"Describes a geometry set that is used by the constraint solver engine.","baseClass":"ConstraintSolver.ConstraintGeometryRecord","properties":[{"name":"Type","type":"PrimitiveProperty","description":"","label":"Constraint Type","priority":90,"typeName":"SubstationPhysical.ConstraintType"}]},"ElectricalPortOwnsPhysicalConstraint":{"schemaItemType":"RelationshipClass","description":"Relationship to associate constraint geometry with Electrical Port.","modifier":"Sealed","baseClass":"BisCore.ElementOwnsChildElements","strength":"Embedding","strengthDirection":"Forward","source":{"multiplicity":"(1..1)","roleLabel":"owns","polymorphic":true,"abstractConstraint":"PowerSystemResourcesPhysical.ElectricalPort","constraintClasses":["PowerSystemResourcesPhysical.ElectricalPort"]},"target":{"multiplicity":"(1..*)","roleLabel":"is owned by","polymorphic":true,"abstractConstraint":"SubstationPhysical.PhysicalConstraint","constraintClasses":["SubstationPhysical.PhysicalConstraint"]}},"StructuralPortOwnsPhysicalConstraint":{"schemaItemType":"RelationshipClass","description":"Relationship to associate constraint geometry with Structural Port.","modifier":"Sealed","baseClass":"BisCore.ElementOwnsChildElements","strength":"Embedding","strengthDirection":"Forward","source":{"multiplicity":"(1..1)","roleLabel":"owns","polymorphic":true,"abstractConstraint":"PowerSystemResourcesPhysical.StructuralPort","constraintClasses":["PowerSystemResourcesPhysical.StructuralPort"]},"target":{"multiplicity":"(1..*)","roleLabel":"is owned by","polymorphic":true,"abstractConstraint":"SubstationPhysical.PhysicalConstraint","constraintClasses":["SubstationPhysical.PhysicalConstraint"]}},"LiveMember":{"schemaItemType":"EntityClass","label":"Live Member","baseClass":"BisCore.PhysicalElement"},"GroundMember":{"schemaItemType":"EntityClass","label":"Ground Member","baseClass":"BisCore.PhysicalElement"},"InsulatorMember":{"schemaItemType":"EntityClass","label":"Insulator Member","baseClass":"BisCore.PhysicalElement"},"LiveMemberOwnsElectricalPort":{"schemaItemType":"RelationshipClass","description":"Relationship to associate Electrical Ports with LiveMember.","modifier":"Sealed","baseClass":"BisCore.ElementOwnsChildElements","strength":"Embedding","strengthDirection":"Forward","source":{"multiplicity":"(1..1)","roleLabel":"owns","polymorphic":true,"abstractConstraint":"SubstationPhysical.LiveMember","constraintClasses":["SubstationPhysical.LiveMember"]},"target":{"multiplicity":"(1..*)","roleLabel":"is owned by","polymorphic":true,"abstractConstraint":"PowerSystemResourcesPhysical.ElectricalPort","constraintClasses":["PowerSystemResourcesPhysical.ElectricalPort"]}},"GroundMemberOwnsStructuralPort":{"schemaItemType":"RelationshipClass","description":"Relationship to associate Structural Ports with GroundMember.","modifier":"Sealed","baseClass":"BisCore.ElementOwnsChildElements","strength":"Embedding","strengthDirection":"Forward","source":{"multiplicity":"(1..1)","roleLabel":"owns","polymorphic":true,"abstractConstraint":"SubstationPhysical.GroundMember","constraintClasses":["SubstationPhysical.GroundMember"]},"target":{"multiplicity":"(1..*)","roleLabel":"is owned by","polymorphic":true,"abstractConstraint":"PowerSystemResourcesPhysical.StructuralPort","constraintClasses":["PowerSystemResourcesPhysical.StructuralPort"]}},"OtherAuxiliaryPhysicalType":{"schemaItemType":"EntityClass","label":"Other Auxiliary Physical Type","baseClass":"PowerSystemResourcesPhysical.AuxiliaryEquipmentPhysicalType"},"EMVTPhysicalType":{"schemaItemType":"EntityClass","label":"Electromagnetic Voltage Transformers Physical Type","description":"Electromagnetic Voltage Transformers \r ","baseClass":"PowerSystemResourcesPhysical.PotentialTransformerPhysicalType"},"OVTPhysicalType":{"schemaItemType":"EntityClass","label":"Optical Voltage Transformers Physical Type","description":"Optical Voltage Transformers \r ","baseClass":"PowerSystemResourcesPhysical.PotentialTransformerPhysicalType"},"CCVTPhysicalType":{"schemaItemType":"EntityClass","label":"Capacitive Coupled Voltage Transformer Physical Type","baseClass":"PowerSystemResourcesPhysical.PotentialTransformerPhysicalType"},"CombinedCTVTPhysicalType":{"schemaItemType":"EntityClass","label":"Combined CT/VT Physical Type","baseClass":"PowerSystemResourcesPhysical.SensorPhysicalType"},"OtherAuxiliary":{"schemaItemType":"EntityClass","label":"Other Auxiliary","baseClass":"PowerSystemResourcesPhysical.AuxiliaryEquipment"},"EMVT":{"schemaItemType":"EntityClass","label":"Electromagnetic Voltage Transformers","description":"Electromagnetic Voltage Transformers \r ","baseClass":"PowerSystemResourcesPhysical.PotentialTransformer"},"OVT":{"schemaItemType":"EntityClass","label":"Optical Voltage Transformers","description":"Optical Voltage Transformers \r ","baseClass":"PowerSystemResourcesPhysical.PotentialTransformer"},"CCVT":{"schemaItemType":"EntityClass","label":"Capacitive Coupled Voltage Transformer","baseClass":"PowerSystemResourcesPhysical.PotentialTransformer"},"CombinedCTVT":{"schemaItemType":"EntityClass","label":"Combined CT/VT ","baseClass":"PowerSystemResourcesPhysical.Sensor"},"NeutralGroundingResistorPhysicalType":{"schemaItemType":"EntityClass","label":"Neutral Grounding Resistor Physical Type","baseClass":"PowerSystemResourcesPhysical.GroundingImpedancePhysicalType"},"NeutralGroundingReactorPhysicalType":{"schemaItemType":"EntityClass","label":"Neutral Grounding Reactor Physical Type","description":"The conductor used to connect the non-current-carrying metal parts of equipment, raceways and other enclosures to the system grounded conductor, grounding electrode conductor, or both, at the service equipment or at the source of a separately-derived system","baseClass":"PowerSystemResourcesPhysical.GroundingImpedancePhysicalType"},"NeutralGroundingResistor":{"schemaItemType":"EntityClass","label":"Neutral Grounding Resistor","baseClass":"PowerSystemResourcesPhysical.GroundingImpedance"},"NeutralGroundingReactor":{"schemaItemType":"EntityClass","label":"Neutral Grounding Reactor","description":"The conductor used to connect the non-current-carrying metal parts of equipment, raceways and other enclosures to the system grounded conductor, grounding electrode conductor, or both, at the service equipment or at the source of a separately-derived system","baseClass":"PowerSystemResourcesPhysical.GroundingImpedance"},"PowerTransformer2WindingsPhysicalType":{"schemaItemType":"EntityClass","label":"Power Transformer - 2 Windings Physical Type","baseClass":"PowerSystemResourcesPhysical.PowerTransformerPhysicalType"},"PowerTransformer3WindingsPhysicalType":{"schemaItemType":"EntityClass","label":"Power Transformer - 3 Windings Physical Type","baseClass":"PowerSystemResourcesPhysical.PowerTransformerPhysicalType"},"DistributionTransformerPhysicalType":{"schemaItemType":"EntityClass","label":"Distribution Transformer Physical Type","baseClass":"PowerSystemResourcesPhysical.PowerTransformerPhysicalType"},"GroundingTransformerwithResistorPhysicalType":{"schemaItemType":"EntityClass","label":"Zigzag Grounding Transformer with Resistor Physical Type","baseClass":"PowerSystemResourcesPhysical.PowerTransformerPhysicalType"},"PowerTransformer2Windings":{"schemaItemType":"EntityClass","label":"Power Transformer - 2 Windings","baseClass":"PowerSystemResourcesPhysical.PowerTransformer"},"PowerTransformer3Windings":{"schemaItemType":"EntityClass","label":"Power Transformer - 3 Windings","baseClass":"PowerSystemResourcesPhysical.PowerTransformer"},"DistributionTransformer":{"schemaItemType":"EntityClass","label":"Distribution Transformer","baseClass":"PowerSystemResourcesPhysical.PowerTransformer"},"GroundingTransformerwithResistor":{"schemaItemType":"EntityClass","label":"Zigzag Grounding Transformer with Resistor","baseClass":"PowerSystemResourcesPhysical.PowerTransformer"},"SeriesCapacitorPhysicalType":{"schemaItemType":"EntityClass","label":"Series Capacitor Physical Type","baseClass":"PowerSystemResourcesPhysical.SeriesCompensatorPhysicalType"},"SeriesReactorPhysicalType":{"schemaItemType":"EntityClass","label":"Series Reactor Physical Type","baseClass":"PowerSystemResourcesPhysical.SeriesCompensatorPhysicalType"},"TCSCPhysicalType":{"schemaItemType":"EntityClass","label":"Thyristor-Controlled Series Capacitor Physical Type","baseClass":"PowerSystemResourcesPhysical.SeriesCompensatorPhysicalType"},"SeriesCapacitor":{"schemaItemType":"EntityClass","label":"Series Capacitor","baseClass":"PowerSystemResourcesPhysical.SeriesCompensator"},"SeriesReactor":{"schemaItemType":"EntityClass","label":"Series Reactor","baseClass":"PowerSystemResourcesPhysical.SeriesCompensator"},"TCSC":{"schemaItemType":"EntityClass","label":"Thyristor-Controlled Series Capacitor","baseClass":"PowerSystemResourcesPhysical.SeriesCompensator"},"PowerCablePhysicalType":{"schemaItemType":"EntityClass","label":"Power Cable Physical Type","baseClass":"PowerSystemResourcesPhysical.ConductorPhysicalType"},"InsulatedPowerCablePhysicalType":{"schemaItemType":"EntityClass","label":"Insulated Power Cable Physical Type","baseClass":"PowerSystemResourcesPhysical.ConductorPhysicalType"},"PowerCable":{"schemaItemType":"EntityClass","label":"Power Cable","baseClass":"PowerSystemResourcesPhysical.Conductor"},"InsulatedPowerCable":{"schemaItemType":"EntityClass","label":"Insulated Power Cable","baseClass":"PowerSystemResourcesPhysical.Conductor"},"BushingPhysicalType":{"schemaItemType":"EntityClass","label":"Bushing Physical Type","baseClass":"SubstationPhysical.OtherAuxiliaryPhysicalType"},"LineTunerPhysicalType":{"schemaItemType":"EntityClass","label":"Line Tuner Physical Type","baseClass":"SubstationPhysical.OtherAuxiliaryPhysicalType"},"SurgeCounterPhysicalType":{"schemaItemType":"EntityClass","label":"Surge Counter Physical Type","baseClass":"SubstationPhysical.OtherAuxiliaryPhysicalType"},"GuyStrainInsulatorPhysicalType":{"schemaItemType":"EntityClass","label":"Guy Strain Insulator Physical Type","baseClass":"SubstationPhysical.OtherAuxiliaryPhysicalType"},"ArcHornPhysicalType":{"schemaItemType":"EntityClass","label":"Arc Horn Physical Type","baseClass":"SubstationPhysical.OtherAuxiliaryPhysicalType"},"CoronaRingPhysicalType":{"schemaItemType":"EntityClass","label":"Corona Ring Physical Type","baseClass":"SubstationPhysical.OtherAuxiliaryPhysicalType"},"AnnunciatorPhysicalType":{"schemaItemType":"EntityClass","label":"Annunciator Physical Type","baseClass":"SubstationPhysical.OtherAuxiliaryPhysicalType"},"StatusIndicatorPhysicalType":{"schemaItemType":"EntityClass","label":"Status Indicator Physical Type","baseClass":"SubstationPhysical.OtherAuxiliaryPhysicalType"},"CableClampsPhysicalType":{"schemaItemType":"EntityClass","label":"Cable Clamps Physical Type","baseClass":"PowerSystemResourcesPhysical.ClampPhysicalType"},"BusClampsPhysicalType":{"schemaItemType":"EntityClass","label":"Bus Clamps Physical Type","baseClass":"PowerSystemResourcesPhysical.ClampPhysicalType"},"Bushing":{"schemaItemType":"EntityClass","label":"Bushing","baseClass":"SubstationPhysical.OtherAuxiliary"},"LineTuner":{"schemaItemType":"EntityClass","label":"Line Tuner","baseClass":"SubstationPhysical.OtherAuxiliary"},"SurgeCounter":{"schemaItemType":"EntityClass","label":"Surge Counter","baseClass":"SubstationPhysical.OtherAuxiliary"},"GuyStrainInsulator":{"schemaItemType":"EntityClass","label":"Guy Strain Insulator","baseClass":"SubstationPhysical.OtherAuxiliary"},"ArcHorn":{"schemaItemType":"EntityClass","label":"Arc Horn","baseClass":"SubstationPhysical.OtherAuxiliary"},"CoronaRing":{"schemaItemType":"EntityClass","label":"Corona Ring","baseClass":"SubstationPhysical.OtherAuxiliary"},"Annunciator":{"schemaItemType":"EntityClass","label":"Annunciator","baseClass":"SubstationPhysical.OtherAuxiliary"},"StatusIndicator":{"schemaItemType":"EntityClass","label":"Status Indicator","baseClass":"SubstationPhysical.OtherAuxiliary"},"CableClamps":{"schemaItemType":"EntityClass","label":"Cable Clamps","baseClass":"PowerSystemResourcesPhysical.Clamp"},"BusClamps":{"schemaItemType":"EntityClass","label":"Bus Clamps","baseClass":"PowerSystemResourcesPhysical.Clamp"},"CableConnectorPhysicalType":{"schemaItemType":"EntityClass","label":"Cable Connector Physical Type","baseClass":"PowerSystemResourcesPhysical.JunctionPhysicalType"},"BusConnectorPhysicalType":{"schemaItemType":"EntityClass","label":"Bus Connector Physical Type","baseClass":"PowerSystemResourcesPhysical.JunctionPhysicalType"},"BusAccessoriesPhysicalType":{"schemaItemType":"EntityClass","label":"Bus Accessories Physical Type","baseClass":"PowerSystemResourcesPhysical.ConnectorPhysicalType"},"CableAccessoriesPhysicalType":{"schemaItemType":"EntityClass","label":"Cable Accessories Physical Type","baseClass":"PowerSystemResourcesPhysical.ConnectorPhysicalType"},"LineHardwarePhysicalType":{"schemaItemType":"EntityClass","label":"Line Hardware Physical Type","baseClass":"PowerSystemResourcesPhysical.ConnectorPhysicalType"},"CableConnector":{"schemaItemType":"EntityClass","label":"Cable Connector","baseClass":"PowerSystemResourcesPhysical.Junction"},"BusConnector":{"schemaItemType":"EntityClass","label":"Bus Connector","baseClass":"PowerSystemResourcesPhysical.Junction"},"BusAccessories":{"schemaItemType":"EntityClass","label":"Bus Accessories","baseClass":"PowerSystemResourcesPhysical.Connector"},"CableAccessories":{"schemaItemType":"EntityClass","label":"Cable Accessories","baseClass":"PowerSystemResourcesPhysical.Connector"},"LineHardware":{"schemaItemType":"EntityClass","label":"Line Hardware","baseClass":"PowerSystemResourcesPhysical.Connector"},"VoltageRegulatorPhysicalType":{"schemaItemType":"EntityClass","label":"Voltage Regulator Physical Type","baseClass":"PowerSystemResourcesPhysical.RegulatingConductingEqPhysicalType"},"ShuntCapacitorPhysicalType":{"schemaItemType":"EntityClass","label":"Shunt Capacitor Physical Type","description":"Single capacitor unit used to inject reactive power (positive Q) to improve voltage ","baseClass":"PowerSystemResourcesPhysical.ShuntCompensatorPhysicalType"},"ShuntCapacitorBankPhysicalType":{"schemaItemType":"EntityClass","label":"Shunt Capacitor Bank Physical Type","description":"Group of capacitor units connected in series/parallel; often switchable in steps \r ","baseClass":"PowerSystemResourcesPhysical.ShuntCompensatorPhysicalType"},"ShuntReactorPhysicalType":{"schemaItemType":"EntityClass","label":"Shunt Reactor Physical Type","baseClass":"PowerSystemResourcesPhysical.ShuntCompensatorPhysicalType"},"ShuntReactorBankPhysicalType":{"schemaItemType":"EntityClass","label":"Shunt Reactor Bank Physical Type","baseClass":"PowerSystemResourcesPhysical.ShuntCompensatorPhysicalType"},"RectifierPhysicalType":{"schemaItemType":"EntityClass","label":"Rectifier Physical Type","baseClass":"PowerSystemResourcesPhysical.PowerElectronicsConnectionPhysicalType"},"InverterPhysicalType":{"schemaItemType":"EntityClass","label":"Inverter Physical Type","baseClass":"PowerSystemResourcesPhysical.PowerElectronicsConnectionPhysicalType"},"VoltageRegulator":{"schemaItemType":"EntityClass","label":"Voltage Regulator","baseClass":"PowerSystemResourcesPhysical.RegulatingConductingEq"},"ShuntCapacitor":{"schemaItemType":"EntityClass","label":"Shunt Capacitor","description":"Single capacitor unit used to inject reactive power (positive Q) to improve voltage ","baseClass":"PowerSystemResourcesPhysical.ShuntCompensator"},"ShuntCapacitorBank":{"schemaItemType":"EntityClass","label":"Shunt Capacitor Bank","description":"Group of capacitor units connected in series/parallel; often switchable in steps \r ","baseClass":"PowerSystemResourcesPhysical.ShuntCompensator"},"ShuntReactor":{"schemaItemType":"EntityClass","label":"Shunt Reactor","baseClass":"PowerSystemResourcesPhysical.ShuntCompensator"},"ShuntReactorBank":{"schemaItemType":"EntityClass","label":"Shunt Reactor Bank","baseClass":"PowerSystemResourcesPhysical.ShuntCompensator"},"Rectifier":{"schemaItemType":"EntityClass","label":"Rectifier","baseClass":"PowerSystemResourcesPhysical.PowerElectronicsConnection"},"Inverter":{"schemaItemType":"EntityClass","label":"Inverter","baseClass":"PowerSystemResourcesPhysical.PowerElectronicsConnection"},"GroundingRodPhysicalType":{"schemaItemType":"EntityClass","label":"Grounding Rod Physical Type","baseClass":"PowerSystemResourcesPhysical.GroundPhysicalType"},"GroundingGridPhysicalType":{"schemaItemType":"EntityClass","label":"Grounding Grid Physical Type","baseClass":"PowerSystemResourcesPhysical.GroundPhysicalType"},"GroundingClampsPhysicalType":{"schemaItemType":"EntityClass","label":"Grounding Clamps Physical Type","baseClass":"PowerSystemResourcesPhysical.GroundPhysicalType"},"GroundingAccessoriesPhysicalType":{"schemaItemType":"EntityClass","label":"Grounding Accessories Physical Type","baseClass":"PowerSystemResourcesPhysical.GroundPhysicalType"},"GroundingRod":{"schemaItemType":"EntityClass","label":"Grounding Rod","baseClass":"PowerSystemResourcesPhysical.Ground"},"GroundingGrid":{"schemaItemType":"EntityClass","label":"Grounding Grid","baseClass":"PowerSystemResourcesPhysical.Ground"},"GroundingClamps":{"schemaItemType":"EntityClass","label":"Grounding Clamps","baseClass":"PowerSystemResourcesPhysical.Ground"},"GroundingAccessories":{"schemaItemType":"EntityClass","label":"Grounding Accessories","baseClass":"PowerSystemResourcesPhysical.Ground"},"FastenersPhysicalType":{"schemaItemType":"EntityClass","label":"Fasteners Physical Type","baseClass":"PowerSystemResourcesPhysical.StructurePhysicalType"},"BoltPhysicalType":{"schemaItemType":"EntityClass","label":"Bolt Physical Type","baseClass":"SubstationPhysical.FastenersPhysicalType"},"WasherPhysicalType":{"schemaItemType":"EntityClass","label":"Washer Physical Type","baseClass":"SubstationPhysical.FastenersPhysicalType"},"NutsPhysicalType":{"schemaItemType":"EntityClass","label":"Nuts Physical Type","baseClass":"SubstationPhysical.FastenersPhysicalType"},"ScrewPhysicalType":{"schemaItemType":"EntityClass","label":"Screw Physical Type","baseClass":"SubstationPhysical.FastenersPhysicalType"},"LiftingLugsPhysicalType":{"schemaItemType":"EntityClass","label":"Lifting Lugs Physical Type","baseClass":"SubstationPhysical.FastenersPhysicalType"},"Fasteners":{"schemaItemType":"EntityClass","label":"Fasteners","baseClass":"PowerSystemResourcesPhysical.Structure"},"Screw":{"schemaItemType":"EntityClass","label":"Screw","baseClass":"SubstationPhysical.Fasteners"},"LiftingLugs":{"schemaItemType":"EntityClass","label":"Lifting Lugs","baseClass":"SubstationPhysical.Fasteners"},"SupportsPhysicalType":{"schemaItemType":"EntityClass","label":"Supports Physical Type","baseClass":"PowerSystemResourcesPhysical.StructurePhysicalType"},"BusSupportPhysicalType":{"schemaItemType":"EntityClass","label":"Bus Support Physical Type","baseClass":"SubstationPhysical.SupportsPhysicalType"},"BracketPhysicalType":{"schemaItemType":"EntityClass","label":"Bracket Physical Type","baseClass":"SubstationPhysical.SupportsPhysicalType"},"UboltPhysicalType":{"schemaItemType":"EntityClass","label":"U-Bolt Physical Type","baseClass":"SubstationPhysical.SupportsPhysicalType"},"MountingKitPhysicalType":{"schemaItemType":"EntityClass","label":"Mounting Kit Physical Type","description":"Additional components needed to mount equipment","baseClass":"SubstationPhysical.SupportsPhysicalType"},"Supports":{"schemaItemType":"EntityClass","label":"Supports","baseClass":"PowerSystemResourcesPhysical.Structure"},"BusSupport":{"schemaItemType":"EntityClass","label":"Bus Support","baseClass":"SubstationPhysical.Supports"},"Bracket":{"schemaItemType":"EntityClass","label":"Bracket","baseClass":"SubstationPhysical.Supports"},"Ubolt":{"schemaItemType":"EntityClass","label":"U-Bolt","baseClass":"SubstationPhysical.Supports"},"MountingKit":{"schemaItemType":"EntityClass","label":"Mounting Kit","description":"Additional components needed to mount equipment","baseClass":"SubstationPhysical.Supports"},"PlatformPhysicalType":{"schemaItemType":"EntityClass","label":"Platform Physical Type","baseClass":"PowerSystemResourcesPhysical.FoundationPhysicalType"},"WalkingPlatformPhysicalType":{"schemaItemType":"EntityClass","label":"Walking platform Physical Type","baseClass":"SubstationPhysical.PlatformPhysicalType"},"SwitchOperatorPlatformPhysicalType":{"schemaItemType":"EntityClass","label":"Switch Operator Platform Physical Type","baseClass":"SubstationPhysical.PlatformPhysicalType"},"Platform":{"schemaItemType":"EntityClass","label":"Platform","baseClass":"PowerSystemResourcesPhysical.Foundation"},"WalkingPlatform":{"schemaItemType":"EntityClass","label":"Walking platform","baseClass":"SubstationPhysical.Platform"},"SwitchOperatorPlatform":{"schemaItemType":"EntityClass","label":"Switch Operator Platform","baseClass":"SubstationPhysical.Platform"},"EquipmentFoundationPhysicalType":{"schemaItemType":"EntityClass","label":"Equipment Foundation Physical Type","baseClass":"PowerSystemResourcesPhysical.FoundationPhysicalType"},"EquipmentFoundation":{"schemaItemType":"EntityClass","label":"Equipment Foundation","baseClass":"PowerSystemResourcesPhysical.Foundation"},"StructureFoundationPhysicalType":{"schemaItemType":"EntityClass","label":"Structure Foundation Physical Type","baseClass":"PowerSystemResourcesPhysical.FoundationPhysicalType"},"StructureFoundation":{"schemaItemType":"EntityClass","label":"Structure Foundation","baseClass":"PowerSystemResourcesPhysical.Foundation"},"ElectricalBuildingPhysicalType":{"schemaItemType":"EntityClass","label":"Electrical Building Physical Type","baseClass":"SubstationPhysical.SubstationPhysicalType"},"LVSwitchPhysicalType":{"schemaItemType":"EntityClass","label":"LV Switches Physical Type","baseClass":"SubstationPhysical.ElectricalBuildingPhysicalType"},"AudioVisualDevicePhysicalType":{"schemaItemType":"EntityClass","label":"Audio Visual Device Physical Type","baseClass":"SubstationPhysical.ElectricalBuildingPhysicalType"},"CommunicationDevicePhysicalType":{"schemaItemType":"EntityClass","label":"Communication Device Physical Type","baseClass":"SubstationPhysical.ElectricalBuildingPhysicalType"},"ElectricPanelPhysicalType":{"schemaItemType":"EntityClass","label":"Electric Panel Physical Type","baseClass":"SubstationPhysical.ElectricalBuildingPhysicalType"},"LVBatteryPhysicalType":{"schemaItemType":"EntityClass","label":"Low Voltage Battery Physical Type","description":"A device in which electrical energy is stored and from which energy may be progressively released.","baseClass":"SubstationPhysical.ElectricalBuildingPhysicalType"},"ConditionerDevicePhysicalType":{"schemaItemType":"EntityClass","label":"Conditioner Device Physical Type","description":"used to remove unwanted matter from an electric or electronic signal","baseClass":"SubstationPhysical.ElectricalBuildingPhysicalType"},"ElectricLoadTimeControlPhysicalType":{"schemaItemType":"EntityClass","label":"Electric Load Time Control Physical Type","description":"A device that applies control to the provision or flow of electrical energy over time ","baseClass":"SubstationPhysical.ElectricalBuildingPhysicalType"},"PowerOutletPhysicalType":{"schemaItemType":"EntityClass","label":"Outlet Physical Type","baseClass":"SubstationPhysical.ElectricalBuildingPhysicalType"},"FanPhysicalType":{"schemaItemType":"EntityClass","label":"Fan Physical Type","baseClass":"SubstationPhysical.ElectricalBuildingPhysicalType"},"LightingFixturePhysicalType":{"schemaItemType":"EntityClass","label":"Lighting Fixture Physical Type","baseClass":"SubstationPhysical.ElectricalBuildingPhysicalType"},"PowerBatteryPhysicalType":{"schemaItemType":"EntityClass","label":"Power Battery Physical Type","baseClass":"SubstationPhysical.ElectricalBuildingPhysicalType"},"EnclosurePhysicalType":{"schemaItemType":"EntityClass","label":"Enclosure Physical Type","baseClass":"SubstationPhysical.ElectricalBuildingPhysicalType"},"SolarDevicePhysicalType":{"schemaItemType":"EntityClass","label":"Solar Device Physical Type","baseClass":"SubstationPhysical.ElectricalBuildingPhysicalType"},"ElectricalBuilding":{"schemaItemType":"EntityClass","label":"Electrical Building","baseClass":"SubstationPhysical.Substation"},"CoverPhysicalType":{"schemaItemType":"EntityClass","label":"Cover Physical Type","baseClass":"SubstationPhysical.EnclosurePhysicalType"},"CabinetPhysicalType":{"schemaItemType":"EntityClass","label":"Cabinet Physical Type","baseClass":"SubstationPhysical.EnclosurePhysicalType"},"GasketPhysicalType":{"schemaItemType":"EntityClass","label":"Gasket Physical Type","baseClass":"SubstationPhysical.EnclosurePhysicalType"},"SecondaryCutOutPhysicalType":{"schemaItemType":"EntityClass","label":"Secondary Cut Out Physical Type","baseClass":"SubstationPhysical.EnclosurePhysicalType"},"PanelboardAssemblyPhysicalType":{"schemaItemType":"EntityClass","label":"Panel Board Assembly Physical Type","baseClass":"SubstationPhysical.EnclosurePhysicalType"},"PullBoxPhysicalType":{"schemaItemType":"EntityClass","label":"Pull Box Physical Type","baseClass":"SubstationPhysical.EnclosurePhysicalType"},"JunctionBoxPhysicalType":{"schemaItemType":"EntityClass","label":"Junction Box Physical Type","description":"A point where one or more conducting equipments are connected with zero resistance.","baseClass":"SubstationPhysical.EnclosurePhysicalType"},"OutletBodyPhysicalType":{"schemaItemType":"EntityClass","label":"Outlet Body Physical Type","baseClass":"SubstationPhysical.EnclosurePhysicalType"},"LVSwitch":{"schemaItemType":"EntityClass","label":"LV Switches","baseClass":"SubstationPhysical.ElectricalBuilding"},"AudioVisualDevice":{"schemaItemType":"EntityClass","label":"Audio Visual Device","baseClass":"SubstationPhysical.ElectricalBuilding"},"CommunicationDevice":{"schemaItemType":"EntityClass","label":"Communication Device","baseClass":"SubstationPhysical.ElectricalBuilding"},"ElectricPanel":{"schemaItemType":"EntityClass","label":"Electric Panel","baseClass":"SubstationPhysical.ElectricalBuilding"},"LVBattery":{"schemaItemType":"EntityClass","label":"Low Voltage Battery","description":"A device in which electrical energy is stored and from which energy may be progressively released.","baseClass":"SubstationPhysical.ElectricalBuilding"},"ConditionerDevice":{"schemaItemType":"EntityClass","label":"Conditioner Device","description":"used to remove unwanted matter from an electric or electronic signal","baseClass":"SubstationPhysical.ElectricalBuilding"},"ElectricLoadTimeControl":{"schemaItemType":"EntityClass","label":"Electric Load Time Control","description":"A device that applies control to the provision or flow of electrical energy over time ","baseClass":"SubstationPhysical.ElectricalBuilding"},"PowerOutlet":{"schemaItemType":"EntityClass","label":"Outlet","baseClass":"SubstationPhysical.ElectricalBuilding"},"Fan":{"schemaItemType":"EntityClass","label":"Fan","baseClass":"SubstationPhysical.ElectricalBuilding"},"LightingFixture":{"schemaItemType":"EntityClass","label":"Lighting Fixture","baseClass":"SubstationPhysical.ElectricalBuilding"},"PowerBattery":{"schemaItemType":"EntityClass","label":"Power Battery","baseClass":"SubstationPhysical.ElectricalBuilding"},"Enclosure":{"schemaItemType":"EntityClass","label":"Enclosure","baseClass":"SubstationPhysical.ElectricalBuilding"},"SolarDevice":{"schemaItemType":"EntityClass","label":"Solar Device","baseClass":"SubstationPhysical.ElectricalBuilding"},"RacewayPhysicalType":{"schemaItemType":"EntityClass","label":"Raceway Physical Type","baseClass":"SubstationPhysical.SubstationPhysicalType"},"Cover":{"schemaItemType":"EntityClass","label":"Cover","baseClass":"SubstationPhysical.Enclosure"},"Cabinet":{"schemaItemType":"EntityClass","label":"Cabinet","baseClass":"SubstationPhysical.Enclosure"},"Gasket":{"schemaItemType":"EntityClass","label":"Gasket","baseClass":"SubstationPhysical.Enclosure"},"SecondaryCutOut":{"schemaItemType":"EntityClass","label":"Secondary Cut Out","baseClass":"SubstationPhysical.Enclosure"},"PanelboardAssembly":{"schemaItemType":"EntityClass","label":"Panel Board Assembly","baseClass":"SubstationPhysical.Enclosure"},"PullBox":{"schemaItemType":"EntityClass","label":"Pull Box","baseClass":"SubstationPhysical.Enclosure"},"JunctionBox":{"schemaItemType":"EntityClass","label":"Junction Box","description":"A point where one or more conducting equipments are connected with zero resistance.","baseClass":"SubstationPhysical.Enclosure"},"OutletBody":{"schemaItemType":"EntityClass","label":"Outlet Body","baseClass":"SubstationPhysical.Enclosure"},"CableTrenchPhysicalType":{"schemaItemType":"EntityClass","label":"Cable Trench Physical Type","baseClass":"SubstationPhysical.RacewayPhysicalType"},"DuctbankPhysicalType":{"schemaItemType":"EntityClass","label":"Duct bank Physical Type","baseClass":"SubstationPhysical.RacewayPhysicalType"},"CableTrayPhysicalType":{"schemaItemType":"EntityClass","label":"Cable Tray Physical Type","baseClass":"SubstationPhysical.RacewayPhysicalType"},"CableLadderPhysicalType":{"schemaItemType":"EntityClass","label":"Cable Ladder Physical Type","baseClass":"SubstationPhysical.RacewayPhysicalType"},"CableLadderFittingPhysicalType":{"schemaItemType":"EntityClass","label":"Cable Ladder Fitting Physical Type","baseClass":"SubstationPhysical.RacewayPhysicalType"},"CableTrayFittingsPhysicalType":{"schemaItemType":"EntityClass","label":"Cable Tray Fittings Physical Type","baseClass":"SubstationPhysical.RacewayPhysicalType"},"CableTrayCoverPhysicalType":{"schemaItemType":"EntityClass","label":"Cable Tray Cover Physical Type","baseClass":"SubstationPhysical.RacewayPhysicalType"},"WirewayPhysicalType":{"schemaItemType":"EntityClass","label":"Wireway Physical Type","baseClass":"SubstationPhysical.RacewayPhysicalType"},"ConduitFittingPhysicalType":{"schemaItemType":"EntityClass","label":"Conduit Fittings Physical Type","baseClass":"SubstationPhysical.RacewayPhysicalType"},"ConduitPhysicalType":{"schemaItemType":"EntityClass","label":"Conduit Physical Type","baseClass":"SubstationPhysical.RacewayPhysicalType"},"Raceway":{"schemaItemType":"EntityClass","label":"Raceway","baseClass":"SubstationPhysical.Substation"},"CableTrench":{"schemaItemType":"EntityClass","label":"Cable Trench","baseClass":"SubstationPhysical.Raceway"},"Ductbank":{"schemaItemType":"EntityClass","label":"Duct bank","baseClass":"SubstationPhysical.Raceway"},"CableTray":{"schemaItemType":"EntityClass","label":"Cable Tray","baseClass":"SubstationPhysical.Raceway"},"CableLadder":{"schemaItemType":"EntityClass","label":"Cable Ladder","baseClass":"SubstationPhysical.Raceway"},"CableLadderFitting":{"schemaItemType":"EntityClass","label":"Cable Ladder Fitting","baseClass":"SubstationPhysical.Raceway"},"CableTrayFittings":{"schemaItemType":"EntityClass","label":"Cable Tray Fittings","baseClass":"SubstationPhysical.Raceway"},"CableTrayCover":{"schemaItemType":"EntityClass","label":"Cable Tray Cover","baseClass":"SubstationPhysical.Raceway"},"Wireway":{"schemaItemType":"EntityClass","label":"Wireway","baseClass":"SubstationPhysical.Raceway"},"ConduitFitting":{"schemaItemType":"EntityClass","label":"Conduit Fittings","baseClass":"SubstationPhysical.Raceway"},"Conduit":{"schemaItemType":"EntityClass","label":"Conduit","baseClass":"SubstationPhysical.Raceway"},"MiscellaneousPhysicalType":{"schemaItemType":"EntityClass","label":"Miscellaneous Physical Type","baseClass":"SubstationPhysical.SubstationPhysicalType"},"FencePhysicalType":{"schemaItemType":"EntityClass","label":"Fence Physical Type","baseClass":"SubstationPhysical.MiscellaneousPhysicalType"},"GatePhysicalType":{"schemaItemType":"EntityClass","label":"Gate Physical Type","baseClass":"SubstationPhysical.MiscellaneousPhysicalType"},"ControlBuildingPhysicalType":{"schemaItemType":"EntityClass","label":"Control Building Physical Type","baseClass":"SubstationPhysical.MiscellaneousPhysicalType"},"OilContainmentSystemPhysicalType":{"schemaItemType":"EntityClass","label":"Oil Containment System Physical Type","baseClass":"SubstationPhysical.MiscellaneousPhysicalType"},"PhysicalSafetyBarrierPhysicalType":{"schemaItemType":"EntityClass","label":"Physical Safety Barrier Physical Type","baseClass":"SubstationPhysical.MiscellaneousPhysicalType"},"GeneralHardwarePhysicalType":{"schemaItemType":"EntityClass","label":"General Hardware Physical Type","baseClass":"SubstationPhysical.MiscellaneousPhysicalType"},"NameplatePhysicalType":{"schemaItemType":"EntityClass","label":"Nameplate Physical Type","description":"Mounted on the equipment, and contains most relevant equipment attributes. Can be provided by manufacturer or created by utility using the data from design.","baseClass":"SubstationPhysical.MiscellaneousPhysicalType"},"TerrainPhysicalType":{"schemaItemType":"EntityClass","label":"Terrain Physical Type","description":"DTM Terrain","baseClass":"SubstationPhysical.MiscellaneousPhysicalType"},"Miscellaneous":{"schemaItemType":"EntityClass","label":"Miscellaneous","baseClass":"SubstationPhysical.Substation"},"AnimalGuardPhysicalType":{"schemaItemType":"EntityClass","label":"Animal Guard Physical Type","baseClass":"SubstationPhysical.PhysicalSafetyBarrierPhysicalType"},"FireBarrierPhysicalType":{"schemaItemType":"EntityClass","label":"Fire Barrier Physical Type","baseClass":"SubstationPhysical.PhysicalSafetyBarrierPhysicalType"},"VehicleBarrierPhysicalType":{"schemaItemType":"EntityClass","label":"Vehicle Barrier Physical Type","baseClass":"SubstationPhysical.PhysicalSafetyBarrierPhysicalType"},"Fence":{"schemaItemType":"EntityClass","label":"Fence","baseClass":"SubstationPhysical.Miscellaneous"},"Gate":{"schemaItemType":"EntityClass","label":"Gate","baseClass":"SubstationPhysical.Miscellaneous"},"ControlBuilding":{"schemaItemType":"EntityClass","label":"Control Building","baseClass":"SubstationPhysical.Miscellaneous"},"OilContainmentSystem":{"schemaItemType":"EntityClass","label":"Oil Containment System","baseClass":"SubstationPhysical.Miscellaneous"},"PhysicalSafetyBarrier":{"schemaItemType":"EntityClass","label":"Physical Safety Barrier","baseClass":"SubstationPhysical.Miscellaneous"},"GeneralHardware":{"schemaItemType":"EntityClass","label":"General Hardware","baseClass":"SubstationPhysical.Miscellaneous"},"Nameplate":{"schemaItemType":"EntityClass","label":"Nameplate","description":"Mounted on the equipment, and contains most relevant equipment attributes. Can be provided by manufacturer or created by utility using the data from design.","baseClass":"SubstationPhysical.Miscellaneous"},"BushingAssembly":{"schemaItemType":"EntityClass","label":"Bushing Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"AnimalGuard":{"schemaItemType":"EntityClass","label":"Animal Guard","baseClass":"SubstationPhysical.PhysicalSafetyBarrier"},"FireBarrier":{"schemaItemType":"EntityClass","label":"Fire Barrier","baseClass":"SubstationPhysical.PhysicalSafetyBarrier"},"VehicleBarrier":{"schemaItemType":"EntityClass","label":"Vehicle Barrier","baseClass":"SubstationPhysical.PhysicalSafetyBarrier"},"LineTunerAssembly":{"schemaItemType":"EntityClass","label":"Line Tuner Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"SurgeCounterAssembly":{"schemaItemType":"EntityClass","label":"Surge Counter Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"GuyStrainInsulatorAssembly":{"schemaItemType":"EntityClass","label":"Guy Strain Insulator Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"ArcHornAssembly":{"schemaItemType":"EntityClass","label":"Arc Horn Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"CoronaRingAssembly":{"schemaItemType":"EntityClass","label":"Corona Ring Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"AnnunciatorAssembly":{"schemaItemType":"EntityClass","label":"Annunciator Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"StatusIndicatorAssembly":{"schemaItemType":"EntityClass","label":"Status Indicator Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"EMVTAssembly":{"schemaItemType":"EntityClass","label":"Electromagnetic Voltage Transformers Assembly","description":"Electromagnetic Voltage Transformers \r ","baseClass":"PowerSystemResourcesPhysical.Equipment"},"OVTAssembly":{"schemaItemType":"EntityClass","label":"Optical Voltage Transformers Assembly","description":"Optical Voltage Transformers \r ","baseClass":"PowerSystemResourcesPhysical.Equipment"},"CCVTAssembly":{"schemaItemType":"EntityClass","label":"Capacitive Coupled Voltage Transformer Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"CombinedCTVTAssembly":{"schemaItemType":"EntityClass","label":"Combined CT/VT Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"NeutralGroundingResistorAssembly":{"schemaItemType":"EntityClass","label":"Neutral Grounding Resistor Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"NeutralGroundingReactorAssembly":{"schemaItemType":"EntityClass","label":"Neutral Grounding Reactor Assembly","description":"The conductor used to connect the non-current-carrying metal parts of equipment, raceways and other enclosures to the system grounded conductor, grounding electrode conductor, or both, at the service equipment or at the source of a separately-derived system","baseClass":"PowerSystemResourcesPhysical.Equipment"},"PowerTransformer2WindingsAssembly":{"schemaItemType":"EntityClass","label":"Power Transformer - 2 Windings Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"PowerTransformer3WindingsAssembly":{"schemaItemType":"EntityClass","label":"Power Transformer - 3 Windings Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"DistributionTransformerAssembly":{"schemaItemType":"EntityClass","label":"Distribution Transformer Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"GroundingTransformerwithResistorAssembly":{"schemaItemType":"EntityClass","label":"Zigzag Grounding Transformer with Resistor Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"SeriesCapacitorAssembly":{"schemaItemType":"EntityClass","label":"Series Capacitor Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"SeriesReactorAssembly":{"schemaItemType":"EntityClass","label":"Series Reactor Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"TCSCAssembly":{"schemaItemType":"EntityClass","label":"Thyristor-Controlled Series Capacitor Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"PowerCableAssembly":{"schemaItemType":"EntityClass","label":"Power Cable Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"InsulatedPowerCableAssembly":{"schemaItemType":"EntityClass","label":"Insulated Power Cable Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"CableClampsAssembly":{"schemaItemType":"EntityClass","label":"Cable Clamps Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"BusClampsAssembly":{"schemaItemType":"EntityClass","label":"Bus Clamps Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"CableConnectorAssembly":{"schemaItemType":"EntityClass","label":"Cable Connector Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"BusConnectorAssembly":{"schemaItemType":"EntityClass","label":"Bus Connector Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"BusAccessoriesAssembly":{"schemaItemType":"EntityClass","label":"Bus Accessories Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"CableAccessoriesAssembly":{"schemaItemType":"EntityClass","label":"Cable Accessories Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"LineHardwareAssembly":{"schemaItemType":"EntityClass","label":"Line Hardware Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"VoltageRegulatorAssembly":{"schemaItemType":"EntityClass","label":"Voltage Regulator Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"ShuntCapacitorAssembly":{"schemaItemType":"EntityClass","label":"Shunt Capacitor Assembly","description":"Single capacitor unit used to inject reactive power (positive Q) to improve voltage ","baseClass":"PowerSystemResourcesPhysical.Equipment"},"ShuntCapacitorBankAssembly":{"schemaItemType":"EntityClass","label":"Shunt Capacitor Bank Assembly","description":"Group of capacitor units connected in series/parallel; often switchable in steps \r ","baseClass":"PowerSystemResourcesPhysical.Equipment"},"ShuntReactorAssembly":{"schemaItemType":"EntityClass","label":"Shunt Reactor Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"ShuntReactorBankAssembly":{"schemaItemType":"EntityClass","label":"Shunt Reactor Bank Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"RectifierAssembly":{"schemaItemType":"EntityClass","label":"Rectifier Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"InverterAssembly":{"schemaItemType":"EntityClass","label":"Inverter Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"GroundingRodAssembly":{"schemaItemType":"EntityClass","label":"Grounding Rod Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"GroundingGridAssembly":{"schemaItemType":"EntityClass","label":"Grounding Grid Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"GroundingClampsAssembly":{"schemaItemType":"EntityClass","label":"Grounding Clamps Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"GroundingAccessoriesAssembly":{"schemaItemType":"EntityClass","label":"Grounding Accessories Assembly","baseClass":"PowerSystemResourcesPhysical.Equipment"},"BoltAssembly":{"schemaItemType":"EntityClass","label":"Bolt Assembly","baseClass":"PowerSystemResourcesPhysical.Structure"},"WasherAssembly":{"schemaItemType":"EntityClass","label":"Washer Assembly","baseClass":"PowerSystemResourcesPhysical.Structure"},"NutsAssembly":{"schemaItemType":"EntityClass","label":"Nuts Assembly","baseClass":"PowerSystemResourcesPhysical.Structure"},"ScrewAssembly":{"schemaItemType":"EntityClass","label":"Screw Assembly","baseClass":"PowerSystemResourcesPhysical.Structure"},"LiftingLugsAssembly":{"schemaItemType":"EntityClass","label":"Lifting Lugs Assembly","baseClass":"PowerSystemResourcesPhysical.Structure"},"BusSupportAssembly":{"schemaItemType":"EntityClass","label":"Bus Support Assembly","baseClass":"PowerSystemResourcesPhysical.Structure"},"BracketAssembly":{"schemaItemType":"EntityClass","label":"Bracket Assembly","baseClass":"PowerSystemResourcesPhysical.Structure"},"UboltAssembly":{"schemaItemType":"EntityClass","label":"U-Bolt Assembly","baseClass":"PowerSystemResourcesPhysical.Structure"},"MountingKitAssembly":{"schemaItemType":"EntityClass","label":"Mounting Kit Assembly","description":"Additional components needed to mount equipment","baseClass":"PowerSystemResourcesPhysical.Structure"},"PlatformAssembly":{"schemaItemType":"EntityClass","label":"Platform Assembly","baseClass":"PowerSystemResourcesPhysical.Foundation"},"WalkingPlatformAssembly":{"schemaItemType":"EntityClass","label":"Walking Platform Assembly","baseClass":"PowerSystemResourcesPhysical.Foundation"},"SwitchOperatorPlatformAssembly":{"schemaItemType":"EntityClass","label":"Switch Operator Platform Assembly","baseClass":"PowerSystemResourcesPhysical.Foundation"},"EquipmentFoundationAssembly":{"schemaItemType":"EntityClass","label":"Equipment Foundation Assembly","baseClass":"PowerSystemResourcesPhysical.Foundation"},"StructureFoundationAssembly":{"schemaItemType":"EntityClass","label":"Structure Foundation Assembly","baseClass":"PowerSystemResourcesPhysical.Foundation"},"LVSwitchAssembly":{"schemaItemType":"EntityClass","label":"LV Switches Assembly","baseClass":"SubstationPhysical.Substation"},"AudioVisualDeviceAssembly":{"schemaItemType":"EntityClass","label":"Audio Visual Device Assembly","baseClass":"SubstationPhysical.Substation"},"CommunicationDeviceAssembly":{"schemaItemType":"EntityClass","label":"Communication Device Assembly","baseClass":"SubstationPhysical.Substation"},"ElectricPanelAssembly":{"schemaItemType":"EntityClass","label":"Electric Panel Assembly","baseClass":"SubstationPhysical.Substation"},"LVBatteryAssembly":{"schemaItemType":"EntityClass","label":"Low Voltage Battery Assembly","baseClass":"SubstationPhysical.Substation"},"ConditionerDeviceAssembly":{"schemaItemType":"EntityClass","label":"Conditioner Device Assembly","baseClass":"SubstationPhysical.Substation"},"ElectricLoadTimeControlAssembly":{"schemaItemType":"EntityClass","label":"Electric Load Time Control Assembly","baseClass":"SubstationPhysical.Substation"},"PowerOutletAssembly":{"schemaItemType":"EntityClass","label":"Outlet Assembly","baseClass":"SubstationPhysical.Substation"},"FanAssembly":{"schemaItemType":"EntityClass","label":"Fan Assembly","baseClass":"SubstationPhysical.Substation"},"LightingFixtureAssembly":{"schemaItemType":"EntityClass","label":"Lighting Fixture Assembly","baseClass":"SubstationPhysical.Substation"},"PowerBatteryAssembly":{"schemaItemType":"EntityClass","label":"Power Battery Assembly","baseClass":"SubstationPhysical.Substation"},"CoverAssembly":{"schemaItemType":"EntityClass","label":"Cover Assembly","baseClass":"SubstationPhysical.Substation"},"CabinetAssembly":{"schemaItemType":"EntityClass","label":"Cabinet Assembly","baseClass":"SubstationPhysical.Substation"},"GasketAssembly":{"schemaItemType":"EntityClass","label":"Gasket Assembly","baseClass":"SubstationPhysical.Substation"},"SecondaryCutOutAssembly":{"schemaItemType":"EntityClass","label":"Secondary Cut Out Assembly","baseClass":"SubstationPhysical.Substation"},"PanelboardAssemblyAssembly":{"schemaItemType":"EntityClass","label":"Panel Board Assembly Assembly","baseClass":"SubstationPhysical.Substation"},"PullBoxAssembly":{"schemaItemType":"EntityClass","label":"Pull Box Assembly","baseClass":"SubstationPhysical.Substation"},"JunctionBoxAssembly":{"schemaItemType":"EntityClass","label":"Junction Box Assembly","description":"A point where one or more conducting equipments are connected with zero resistance.","baseClass":"SubstationPhysical.Substation"},"OutletBodyAssembly":{"schemaItemType":"EntityClass","label":"Outlet Body Assembly","baseClass":"SubstationPhysical.Substation"},"SolarDeviceAssembly":{"schemaItemType":"EntityClass","label":"Solar Device Assembly","baseClass":"SubstationPhysical.Substation"},"CableTrenchAssembly":{"schemaItemType":"EntityClass","label":"Cable Trench Assembly","baseClass":"SubstationPhysical.Substation"},"DuctbankAssembly":{"schemaItemType":"EntityClass","label":"Duct bank Assembly","baseClass":"SubstationPhysical.Substation"},"CableTrayAssembly":{"schemaItemType":"EntityClass","label":"Cable Tray Assembly","baseClass":"SubstationPhysical.Substation"},"CableLadderAssembly":{"schemaItemType":"EntityClass","label":"Cable Ladder Assembly","baseClass":"SubstationPhysical.Substation"},"CableLadderFittingAssembly":{"schemaItemType":"EntityClass","label":"Cable Ladder Fitting Assembly","baseClass":"SubstationPhysical.Substation"},"CableTrayFittingsAssembly":{"schemaItemType":"EntityClass","label":"Cable Tray Fittings Assembly","baseClass":"SubstationPhysical.Substation"},"CableTrayCoverAssembly":{"schemaItemType":"EntityClass","label":"Cable Tray Cover Assembly","baseClass":"SubstationPhysical.Substation"},"WirewayAssembly":{"schemaItemType":"EntityClass","label":"Wireway Assembly","baseClass":"SubstationPhysical.Substation"},"ConduitFittingAssembly":{"schemaItemType":"EntityClass","label":"Conduit Fittings Assembly","baseClass":"SubstationPhysical.Substation"},"ConduitAssembly":{"schemaItemType":"EntityClass","label":"Conduit Assembly","baseClass":"SubstationPhysical.Substation"},"FenceAssembly":{"schemaItemType":"EntityClass","label":"Fence Assembly","baseClass":"SubstationPhysical.Substation"},"GateAssembly":{"schemaItemType":"EntityClass","label":"Gate Assembly","baseClass":"SubstationPhysical.Substation"},"ControlBuildingAssembly":{"schemaItemType":"EntityClass","label":"Control Building Assembly","baseClass":"SubstationPhysical.Substation"},"OilContainmentSystemAssembly":{"schemaItemType":"EntityClass","label":"Oil Containment System Assembly","baseClass":"SubstationPhysical.Substation"},"AnimalGuardAssembly":{"schemaItemType":"EntityClass","label":"Animal Guard Assembly","baseClass":"SubstationPhysical.Substation"},"FireBarrierAssembly":{"schemaItemType":"EntityClass","label":"Fire Barrier Assembly","baseClass":"SubstationPhysical.Substation"},"VehicleBarrierAssembly":{"schemaItemType":"EntityClass","label":"Vehicle Barrier Assembly","baseClass":"SubstationPhysical.Substation"},"GeneralHardwareAssembly":{"schemaItemType":"EntityClass","label":"General Hardware Assembly","baseClass":"SubstationPhysical.Substation"},"NameplateAssembly":{"schemaItemType":"EntityClass","label":"Nameplate Assembly","baseClass":"SubstationPhysical.Substation"},"TerrainAssembly":{"schemaItemType":"EntityClass","label":"Terrain Assembly","baseClass":"SubstationPhysical.Substation"}}}
@@ -13,7 +13,7 @@
13
13
  <ECSchemaReference name="BisCustomAttributes" version="01.00.00" alias="bisCA" />
14
14
  <ECCustomAttributes>
15
15
  <ProductionStatus xmlns="CoreCustomAttributes.01.00.04">
16
- <SupportedUse>NotForProduction</SupportedUse>
16
+ <SupportedUse>FieldTesting</SupportedUse>
17
17
  </ProductionStatus>
18
18
  <SchemaLayerInfo xmlns="BisCustomAttributes.01.00.00">
19
19
  <Value>Application</Value>
package/package.json CHANGED
@@ -1,7 +1,7 @@
1
1
  {
2
2
  "name": "@bentley/substation-physical-schema",
3
3
  "license": "MIT",
4
- "version": "1.0.5-dev.1",
4
+ "version": "1.0.5",
5
5
  "homepage": "https://www.itwinjs.org/",
6
6
  "keywords": [
7
7
  "Bentley",