@bentley/substation-functional-schema 1.0.5-dev.1 → 1.0.5
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
|
@@ -1 +1 @@
|
|
|
1
|
-
{"$schema":"https://dev.bentley.com/json_schemas/ec/32/ecschema","name":"SubstationFunctional","version":"01.00.05","alias":"subfunc","label":"SubstationFunctional","description":"This schema contains classes used for Substation Design.","references":[{"name":"BisCore","version":"01.00.26"},{"name":"Functional","version":"01.00.05"},{"name":"PowerSystemResourcesFunctional","version":"01.00.01"},{"name":"CoreCustomAttributes","version":"01.00.05"},{"name":"BisCustomAttributes","version":"01.00.00"}],"customAttributes":[{"className":"CoreCustomAttributes.ProductionStatus","SupportedUse":"NotForProduction"},{"className":"BisCustomAttributes.SchemaLayerInfo","Value":"Application"}],"items":{"FunctionalContainer":{"schemaItemType":"EntityClass","label":"Functional Container","description":"Container for definition-oriented functional elements.","baseClass":"BisCore.DefinitionElement","mixins":["BisCore.ISubModeledElement"]},"ElectricalPotential":{"schemaItemType":"EntityClass","label":"Electrical Potential Element","description":"An ElectricalPotential Element is a functional element that groups connected ElectricalWire Elements that carry the same voltage).","baseClass":"Functional.FunctionalBreakdownElement"},"ElectricalWire":{"schemaItemType":"EntityClass","label":"Electrical Wire Element","description":"An ElectricalWire Element is a system EquipmentFunctional element that connects two ElectricalTerminal Elements.","baseClass":"PowerSystemResourcesFunctional.EquipmentFunctional"},"SubstationFunctional":{"schemaItemType":"EntityClass","label":"Substation Functional","baseClass":"Functional.FunctionalComponentElement","properties":[{"name":"CodeValue","type":"PrimitiveProperty","label":"Device Id","typeName":"string"},{"name":"DeviceTag","type":"PrimitiveProperty","label":"Device Tag","typeName":"string"}]},"SubstationFunctionalAspect":{"schemaItemType":"EntityClass","label":"Substation Aspect","modifier":"Abstract","baseClass":"BisCore.ElementUniqueAspect"},"OtherAuxiliaryFunctional":{"schemaItemType":"EntityClass","label":"Other Auxiliary","baseClass":"PowerSystemResourcesFunctional.AuxiliaryEquipmentFunctional"},"EMVTFunctional":{"schemaItemType":"EntityClass","label":"Electromagnetic Voltage Transformers","description":"Electromagnetic Voltage Transformers \r ","baseClass":"PowerSystemResourcesFunctional.PotentialTransformerFunctional"},"OVTFunctional":{"schemaItemType":"EntityClass","label":"Optical Voltage Transformers","description":"Optical Voltage Transformers \r ","baseClass":"PowerSystemResourcesFunctional.PotentialTransformerFunctional"},"CCVTFunctional":{"schemaItemType":"EntityClass","label":"Capacitive Coupled Voltage Transformer","baseClass":"PowerSystemResourcesFunctional.PotentialTransformerFunctional"},"CombinedCTVTFunctional":{"schemaItemType":"EntityClass","label":"Combined CT/VT ","baseClass":"PowerSystemResourcesFunctional.SensorFunctional"},"NeutralGroundingResistorFunctional":{"schemaItemType":"EntityClass","label":"Neutral Grounding Resistor","baseClass":"PowerSystemResourcesFunctional.GroundingImpedanceFunctional"},"NeutralGroundingReactorFunctional":{"schemaItemType":"EntityClass","label":"Neutral Grounding Reactor","description":"The conductor used to connect the non-current-carrying metal parts of equipment, raceways and other enclosures to the system grounded conductor, grounding electrode conductor, or both, at the service equipment or at the source of a separately-derived system","baseClass":"PowerSystemResourcesFunctional.GroundingImpedanceFunctional"},"PowerTransformer2WindingsFunctional":{"schemaItemType":"EntityClass","label":"Power Transformer - 2 Windings","baseClass":"PowerSystemResourcesFunctional.PowerTransformerFunctional"},"PowerTransformer3WindingsFunctional":{"schemaItemType":"EntityClass","label":"Power Transformer - 3 Windings","baseClass":"PowerSystemResourcesFunctional.PowerTransformerFunctional"},"DistributionTransformerFunctional":{"schemaItemType":"EntityClass","label":"Distribution Transformer","baseClass":"PowerSystemResourcesFunctional.PowerTransformerFunctional"},"GroundingTransformerwithResistorFunctional":{"schemaItemType":"EntityClass","label":"Zigzag Grounding Transformer with Resistor","baseClass":"PowerSystemResourcesFunctional.PowerTransformerFunctional"},"SeriesCapacitorFunctional":{"schemaItemType":"EntityClass","label":"Series Capacitor","baseClass":"PowerSystemResourcesFunctional.SeriesCompensatorFunctional"},"SeriesReactorFunctional":{"schemaItemType":"EntityClass","label":"Series Reactor","baseClass":"PowerSystemResourcesFunctional.SeriesCompensatorFunctional"},"TCSCFunctional":{"schemaItemType":"EntityClass","label":"Thyristor-Controlled Series Capacitor","baseClass":"PowerSystemResourcesFunctional.SeriesCompensatorFunctional"},"PowerCableFunctional":{"schemaItemType":"EntityClass","label":"Power Cable","baseClass":"PowerSystemResourcesFunctional.ConductorFunctional"},"InsulatedPowerCableFunctional":{"schemaItemType":"EntityClass","label":"Insulated Power Cable","baseClass":"PowerSystemResourcesFunctional.ConductorFunctional"},"CableClampsFunctional":{"schemaItemType":"EntityClass","label":"Cable Clamps","baseClass":"PowerSystemResourcesFunctional.ClampFunctional"},"BusClampsFunctional":{"schemaItemType":"EntityClass","label":"Bus Clamps","baseClass":"PowerSystemResourcesFunctional.ClampFunctional"},"CableConnectorFunctional":{"schemaItemType":"EntityClass","label":"Cable Connector","baseClass":"PowerSystemResourcesFunctional.JunctionFunctional"},"BusConnectorFunctional":{"schemaItemType":"EntityClass","label":"Bus Connector","baseClass":"PowerSystemResourcesFunctional.JunctionFunctional"},"BusAccessoriesFunctional":{"schemaItemType":"EntityClass","label":"Bus Accessories","baseClass":"PowerSystemResourcesFunctional.ConnectorFunctional"},"CableAccessoriesFunctional":{"schemaItemType":"EntityClass","label":"Cable Accessories","baseClass":"PowerSystemResourcesFunctional.ConnectorFunctional"},"LineHardwareFunctional":{"schemaItemType":"EntityClass","label":"Line Hardware","baseClass":"PowerSystemResourcesFunctional.ConnectorFunctional"},"VoltageRegulatorFunctional":{"schemaItemType":"EntityClass","label":"Voltage Regulator","baseClass":"PowerSystemResourcesFunctional.RegulatingConductingEqFunctional"},"ShuntCapacitorFunctional":{"schemaItemType":"EntityClass","label":"Shunt Capacitor","description":"Single capacitor unit used to inject reactive power (positive Q) to improve voltage ","baseClass":"PowerSystemResourcesFunctional.ShuntCompensatorFunctional"},"ShuntCapacitorBankFunctional":{"schemaItemType":"EntityClass","label":"Shunt Capacitor Bank","description":"Group of capacitor units connected in series/parallel; often switchable in steps \r ","baseClass":"PowerSystemResourcesFunctional.ShuntCompensatorFunctional"},"ShuntReactorFunctional":{"schemaItemType":"EntityClass","label":"Shunt Reactor","baseClass":"PowerSystemResourcesFunctional.ShuntCompensatorFunctional"},"ShuntReactorBankFunctional":{"schemaItemType":"EntityClass","label":"Shunt Reactor Bank","baseClass":"PowerSystemResourcesFunctional.ShuntCompensatorFunctional"},"RectifierFunctional":{"schemaItemType":"EntityClass","label":"Rectifier","baseClass":"PowerSystemResourcesFunctional.PowerElectronicsConnectionFunctional"},"InverterFunctional":{"schemaItemType":"EntityClass","label":"Inverter","baseClass":"PowerSystemResourcesFunctional.PowerElectronicsConnectionFunctional"},"GroundingRodFunctional":{"schemaItemType":"EntityClass","label":"Grounding Rod","baseClass":"PowerSystemResourcesFunctional.GroundFunctional"},"GroundingGridFunctional":{"schemaItemType":"EntityClass","label":"Grounding Grid","baseClass":"PowerSystemResourcesFunctional.GroundFunctional"},"GroundingClampsFunctional":{"schemaItemType":"EntityClass","label":"Grounding Clamps","baseClass":"PowerSystemResourcesFunctional.GroundFunctional"},"GroundingAccessoriesFunctional":{"schemaItemType":"EntityClass","label":"Grounding Accessories","baseClass":"PowerSystemResourcesFunctional.GroundFunctional"},"BushingFunctional":{"schemaItemType":"EntityClass","label":"Bushing","baseClass":"SubstationFunctional.OtherAuxiliaryFunctional"},"LineTunerFunctional":{"schemaItemType":"EntityClass","label":"Line Tuner","baseClass":"SubstationFunctional.OtherAuxiliaryFunctional"},"SurgeCounterFunctional":{"schemaItemType":"EntityClass","label":"Surge Counter","baseClass":"SubstationFunctional.OtherAuxiliaryFunctional"},"GuyStrainInsulatorFunctional":{"schemaItemType":"EntityClass","label":"Guy Strain Insulator","baseClass":"SubstationFunctional.OtherAuxiliaryFunctional"},"ArcHornFunctional":{"schemaItemType":"EntityClass","label":"Arc Horn","baseClass":"SubstationFunctional.OtherAuxiliaryFunctional"},"CoronaRingFunctional":{"schemaItemType":"EntityClass","label":"Corona Ring","baseClass":"SubstationFunctional.OtherAuxiliaryFunctional"},"AnnunciatorFunctional":{"schemaItemType":"EntityClass","label":"Annunciator","baseClass":"SubstationFunctional.OtherAuxiliaryFunctional"},"StatusIndicatorFunctional":{"schemaItemType":"EntityClass","label":"Status Indicator","baseClass":"SubstationFunctional.OtherAuxiliaryFunctional"},"FastenersFunctional":{"schemaItemType":"EntityClass","label":"Fasteners","baseClass":"PowerSystemResourcesFunctional.StructureFunctional"},"BoltFunctional":{"schemaItemType":"EntityClass","label":"Bolt","baseClass":"SubstationFunctional.FastenersFunctional"},"WasherFunctional":{"schemaItemType":"EntityClass","label":"Washer","baseClass":"SubstationFunctional.FastenersFunctional"},"NutsFunctional":{"schemaItemType":"EntityClass","label":"Nuts","baseClass":"SubstationFunctional.FastenersFunctional"},"ScrewFunctional":{"schemaItemType":"EntityClass","label":"Screw","baseClass":"SubstationFunctional.FastenersFunctional"},"LiftingLugsFunctional":{"schemaItemType":"EntityClass","label":"Lifting Lugs","baseClass":"SubstationFunctional.FastenersFunctional"},"SupportsFunctional":{"schemaItemType":"EntityClass","label":"Supports","baseClass":"PowerSystemResourcesFunctional.StructureFunctional"},"BusSupportFunctional":{"schemaItemType":"EntityClass","label":"Bus Support","baseClass":"SubstationFunctional.SupportsFunctional"},"BracketFunctional":{"schemaItemType":"EntityClass","label":"Bracket","baseClass":"SubstationFunctional.SupportsFunctional"},"UboltFunctional":{"schemaItemType":"EntityClass","label":"U-Bolt","baseClass":"SubstationFunctional.SupportsFunctional"},"MountingKitFunctional":{"schemaItemType":"EntityClass","label":"Mounting Kit","description":"Additional components needed to mount equipment","baseClass":"SubstationFunctional.SupportsFunctional"},"PlatformFunctional":{"schemaItemType":"EntityClass","label":"Platform","baseClass":"PowerSystemResourcesFunctional.FoundationFunctional"},"WalkingPlatformFunctional":{"schemaItemType":"EntityClass","label":"Walking platform","baseClass":"SubstationFunctional.PlatformFunctional"},"SwitchOperatorPlatformFunctional":{"schemaItemType":"EntityClass","label":"Switch Operator Platform","baseClass":"SubstationFunctional.PlatformFunctional"},"EquipmentFoundationFunctional":{"schemaItemType":"EntityClass","label":"Equipment Foundation","baseClass":"PowerSystemResourcesFunctional.FoundationFunctional"},"StructureFoundationFunctional":{"schemaItemType":"EntityClass","label":"Structure Foundation","baseClass":"PowerSystemResourcesFunctional.FoundationFunctional"},"ElectricalBuildingFunctional":{"schemaItemType":"EntityClass","label":"Electrical Building","baseClass":"SubstationFunctional.SubstationFunctional"},"LVSwitchFunctional":{"schemaItemType":"EntityClass","label":"LV Switches","baseClass":"SubstationFunctional.ElectricalBuildingFunctional"},"AudioVisualDeviceFunctional":{"schemaItemType":"EntityClass","label":"Audio Visual Device","baseClass":"SubstationFunctional.ElectricalBuildingFunctional"},"CommunicationDeviceFunctional":{"schemaItemType":"EntityClass","label":"Communication Device","baseClass":"SubstationFunctional.ElectricalBuildingFunctional"},"ElectricPanelFunctional":{"schemaItemType":"EntityClass","label":"Electric Panel","baseClass":"SubstationFunctional.ElectricalBuildingFunctional"},"LVBatteryFunctional":{"schemaItemType":"EntityClass","label":"Low Voltage Battery","description":"A device in which electrical energy is stored and from which energy may be progressively released.","baseClass":"SubstationFunctional.ElectricalBuildingFunctional"},"ConditionerDeviceFunctional":{"schemaItemType":"EntityClass","label":"Conditioner Device","description":"used to remove unwanted matter from an electric or electronic signal","baseClass":"SubstationFunctional.ElectricalBuildingFunctional"},"ElectricLoadTimeControlFunctional":{"schemaItemType":"EntityClass","label":"Electric Load Time Control","description":"A device that applies control to the provision or flow of electrical energy over time ","baseClass":"SubstationFunctional.ElectricalBuildingFunctional"},"PowerOutletFunctional":{"schemaItemType":"EntityClass","label":"Outlet","baseClass":"SubstationFunctional.ElectricalBuildingFunctional"},"FanFunctional":{"schemaItemType":"EntityClass","label":"Fan","baseClass":"SubstationFunctional.ElectricalBuildingFunctional"},"LightingFixtureFunctional":{"schemaItemType":"EntityClass","label":"Lighting Fixture","baseClass":"SubstationFunctional.ElectricalBuildingFunctional"},"PowerBatteryFunctional":{"schemaItemType":"EntityClass","label":"Power Battery","baseClass":"SubstationFunctional.ElectricalBuildingFunctional"},"EnclosureFunctional":{"schemaItemType":"EntityClass","label":"Enclosure","baseClass":"SubstationFunctional.ElectricalBuildingFunctional"},"SolarDeviceFunctional":{"schemaItemType":"EntityClass","label":"Solar Device","baseClass":"SubstationFunctional.ElectricalBuildingFunctional"},"RacewayFunctional":{"schemaItemType":"EntityClass","label":"Raceway","baseClass":"SubstationFunctional.SubstationFunctional"},"CoverFunctional":{"schemaItemType":"EntityClass","label":"Cover","baseClass":"SubstationFunctional.EnclosureFunctional"},"CabinetFunctional":{"schemaItemType":"EntityClass","label":"Cabinet","baseClass":"SubstationFunctional.EnclosureFunctional"},"GasketFunctional":{"schemaItemType":"EntityClass","label":"Gasket","baseClass":"SubstationFunctional.EnclosureFunctional"},"SecondaryCutOutFunctional":{"schemaItemType":"EntityClass","label":"Secondary Cut Out","baseClass":"SubstationFunctional.EnclosureFunctional"},"PanelboardAssemblyFunctional":{"schemaItemType":"EntityClass","label":"Panel Board Assembly","baseClass":"SubstationFunctional.EnclosureFunctional"},"PullBoxFunctional":{"schemaItemType":"EntityClass","label":"Pull Box","baseClass":"SubstationFunctional.EnclosureFunctional"},"JunctionBoxFunctional":{"schemaItemType":"EntityClass","label":"Junction Box","description":"A point where one or more conducting equipments are connected with zero resistance.","baseClass":"SubstationFunctional.EnclosureFunctional"},"OutletBodyFunctional":{"schemaItemType":"EntityClass","label":"Outlet Body","baseClass":"SubstationFunctional.EnclosureFunctional"},"CableTrenchFunctional":{"schemaItemType":"EntityClass","label":"Cable Trench","baseClass":"SubstationFunctional.RacewayFunctional"},"DuctbankFunctional":{"schemaItemType":"EntityClass","label":"Duct bank","baseClass":"SubstationFunctional.RacewayFunctional"},"CableTrayFunctional":{"schemaItemType":"EntityClass","label":"Cable Tray","baseClass":"SubstationFunctional.RacewayFunctional"},"CableLadderFunctional":{"schemaItemType":"EntityClass","label":"Cable Ladder","baseClass":"SubstationFunctional.RacewayFunctional"},"CableLadderFittingFunctional":{"schemaItemType":"EntityClass","label":"Cable Ladder Fitting","baseClass":"SubstationFunctional.RacewayFunctional"},"CableTrayFittingsFunctional":{"schemaItemType":"EntityClass","label":"Cable Tray Fittings","baseClass":"SubstationFunctional.RacewayFunctional"},"CableTrayCoverFunctional":{"schemaItemType":"EntityClass","label":"Cable Tray Cover","baseClass":"SubstationFunctional.RacewayFunctional"},"WirewayFunctional":{"schemaItemType":"EntityClass","label":"Wireway","baseClass":"SubstationFunctional.RacewayFunctional"},"ConduitFittingFunctional":{"schemaItemType":"EntityClass","label":"Conduit Fittings","baseClass":"SubstationFunctional.RacewayFunctional"},"ConduitFunctional":{"schemaItemType":"EntityClass","label":"Conduit","baseClass":"SubstationFunctional.RacewayFunctional"},"MiscellaneousFunctional":{"schemaItemType":"EntityClass","label":"Miscellaneous","baseClass":"SubstationFunctional.SubstationFunctional"},"FenceFunctional":{"schemaItemType":"EntityClass","label":"Fence","baseClass":"SubstationFunctional.MiscellaneousFunctional"},"GateFunctional":{"schemaItemType":"EntityClass","label":"Gate","baseClass":"SubstationFunctional.MiscellaneousFunctional"},"ControlBuildingFunctional":{"schemaItemType":"EntityClass","label":"Control Building","baseClass":"SubstationFunctional.MiscellaneousFunctional"},"OilContainmentSystemFunctional":{"schemaItemType":"EntityClass","label":"Oil Containment System","baseClass":"SubstationFunctional.MiscellaneousFunctional"},"PhysicalSafetyBarrierFunctional":{"schemaItemType":"EntityClass","label":"Physical Safety Barrier","baseClass":"SubstationFunctional.MiscellaneousFunctional"},"GeneralHardwareFunctional":{"schemaItemType":"EntityClass","label":"General Hardware","baseClass":"SubstationFunctional.MiscellaneousFunctional"},"NameplateFunctional":{"schemaItemType":"EntityClass","label":"Nameplate","description":"Mounted on the equipment, and contains most relevant equipment attributes. Can be provided by manufacturer or created by utility using the data from design.","baseClass":"SubstationFunctional.MiscellaneousFunctional"},"TerrainFunctional":{"schemaItemType":"EntityClass","label":"Terrain","description":"DTM Terrain","baseClass":"SubstationFunctional.MiscellaneousFunctional"},"AnimalGuardFunctional":{"schemaItemType":"EntityClass","label":"Animal Guard","baseClass":"SubstationFunctional.PhysicalSafetyBarrierFunctional"},"FireBarrierFunctional":{"schemaItemType":"EntityClass","label":"Fire Barrier","baseClass":"SubstationFunctional.PhysicalSafetyBarrierFunctional"},"VehicleBarrierFunctional":{"schemaItemType":"EntityClass","label":"Vehicle Barrier","baseClass":"SubstationFunctional.PhysicalSafetyBarrierFunctional"}}}
|
|
1
|
+
{"$schema":"https://dev.bentley.com/json_schemas/ec/32/ecschema","name":"SubstationFunctional","version":"01.00.05","alias":"subfunc","label":"SubstationFunctional","description":"This schema contains classes used for Substation Design.","references":[{"name":"BisCore","version":"01.00.25"},{"name":"Functional","version":"01.00.04"},{"name":"PowerSystemResourcesFunctional","version":"01.00.01"},{"name":"CoreCustomAttributes","version":"01.00.04"},{"name":"BisCustomAttributes","version":"01.00.00"}],"customAttributes":[{"className":"CoreCustomAttributes.ProductionStatus","SupportedUse":"FieldTesting"},{"className":"BisCustomAttributes.SchemaLayerInfo","Value":"Application"}],"items":{"FunctionalContainer":{"schemaItemType":"EntityClass","label":"Functional Container","description":"Container for definition-oriented functional elements.","baseClass":"BisCore.DefinitionElement","mixins":["BisCore.ISubModeledElement"]},"ElectricalPotential":{"schemaItemType":"EntityClass","label":"Electrical Potential Element","description":"An ElectricalPotential Element is a functional element that groups connected ElectricalWire Elements that carry the same voltage).","baseClass":"Functional.FunctionalBreakdownElement"},"ElectricalWire":{"schemaItemType":"EntityClass","label":"Electrical Wire Element","description":"An ElectricalWire Element is a system EquipmentFunctional element that connects two ElectricalTerminal Elements.","baseClass":"PowerSystemResourcesFunctional.EquipmentFunctional"},"SubstationFunctional":{"schemaItemType":"EntityClass","label":"Substation Functional","baseClass":"Functional.FunctionalComponentElement","properties":[{"name":"CodeValue","type":"PrimitiveProperty","label":"Device Id","typeName":"string"},{"name":"DeviceTag","type":"PrimitiveProperty","label":"Device Tag","typeName":"string"}]},"SubstationFunctionalAspect":{"schemaItemType":"EntityClass","label":"Substation Aspect","modifier":"Abstract","baseClass":"BisCore.ElementUniqueAspect"},"OtherAuxiliaryFunctional":{"schemaItemType":"EntityClass","label":"Other Auxiliary","baseClass":"PowerSystemResourcesFunctional.AuxiliaryEquipmentFunctional"},"EMVTFunctional":{"schemaItemType":"EntityClass","label":"Electromagnetic Voltage Transformers","description":"Electromagnetic Voltage Transformers \r ","baseClass":"PowerSystemResourcesFunctional.PotentialTransformerFunctional"},"OVTFunctional":{"schemaItemType":"EntityClass","label":"Optical Voltage Transformers","description":"Optical Voltage Transformers \r ","baseClass":"PowerSystemResourcesFunctional.PotentialTransformerFunctional"},"CCVTFunctional":{"schemaItemType":"EntityClass","label":"Capacitive Coupled Voltage Transformer","baseClass":"PowerSystemResourcesFunctional.PotentialTransformerFunctional"},"CombinedCTVTFunctional":{"schemaItemType":"EntityClass","label":"Combined CT/VT ","baseClass":"PowerSystemResourcesFunctional.SensorFunctional"},"NeutralGroundingResistorFunctional":{"schemaItemType":"EntityClass","label":"Neutral Grounding Resistor","baseClass":"PowerSystemResourcesFunctional.GroundingImpedanceFunctional"},"NeutralGroundingReactorFunctional":{"schemaItemType":"EntityClass","label":"Neutral Grounding Reactor","description":"The conductor used to connect the non-current-carrying metal parts of equipment, raceways and other enclosures to the system grounded conductor, grounding electrode conductor, or both, at the service equipment or at the source of a separately-derived system","baseClass":"PowerSystemResourcesFunctional.GroundingImpedanceFunctional"},"PowerTransformer2WindingsFunctional":{"schemaItemType":"EntityClass","label":"Power Transformer - 2 Windings","baseClass":"PowerSystemResourcesFunctional.PowerTransformerFunctional"},"PowerTransformer3WindingsFunctional":{"schemaItemType":"EntityClass","label":"Power Transformer - 3 Windings","baseClass":"PowerSystemResourcesFunctional.PowerTransformerFunctional"},"DistributionTransformerFunctional":{"schemaItemType":"EntityClass","label":"Distribution Transformer","baseClass":"PowerSystemResourcesFunctional.PowerTransformerFunctional"},"GroundingTransformerwithResistorFunctional":{"schemaItemType":"EntityClass","label":"Zigzag Grounding Transformer with Resistor","baseClass":"PowerSystemResourcesFunctional.PowerTransformerFunctional"},"SeriesCapacitorFunctional":{"schemaItemType":"EntityClass","label":"Series Capacitor","baseClass":"PowerSystemResourcesFunctional.SeriesCompensatorFunctional"},"SeriesReactorFunctional":{"schemaItemType":"EntityClass","label":"Series Reactor","baseClass":"PowerSystemResourcesFunctional.SeriesCompensatorFunctional"},"TCSCFunctional":{"schemaItemType":"EntityClass","label":"Thyristor-Controlled Series Capacitor","baseClass":"PowerSystemResourcesFunctional.SeriesCompensatorFunctional"},"PowerCableFunctional":{"schemaItemType":"EntityClass","label":"Power Cable","baseClass":"PowerSystemResourcesFunctional.ConductorFunctional"},"InsulatedPowerCableFunctional":{"schemaItemType":"EntityClass","label":"Insulated Power Cable","baseClass":"PowerSystemResourcesFunctional.ConductorFunctional"},"CableClampsFunctional":{"schemaItemType":"EntityClass","label":"Cable Clamps","baseClass":"PowerSystemResourcesFunctional.ClampFunctional"},"BusClampsFunctional":{"schemaItemType":"EntityClass","label":"Bus Clamps","baseClass":"PowerSystemResourcesFunctional.ClampFunctional"},"CableConnectorFunctional":{"schemaItemType":"EntityClass","label":"Cable Connector","baseClass":"PowerSystemResourcesFunctional.JunctionFunctional"},"BusConnectorFunctional":{"schemaItemType":"EntityClass","label":"Bus Connector","baseClass":"PowerSystemResourcesFunctional.JunctionFunctional"},"BusAccessoriesFunctional":{"schemaItemType":"EntityClass","label":"Bus Accessories","baseClass":"PowerSystemResourcesFunctional.ConnectorFunctional"},"CableAccessoriesFunctional":{"schemaItemType":"EntityClass","label":"Cable Accessories","baseClass":"PowerSystemResourcesFunctional.ConnectorFunctional"},"LineHardwareFunctional":{"schemaItemType":"EntityClass","label":"Line Hardware","baseClass":"PowerSystemResourcesFunctional.ConnectorFunctional"},"VoltageRegulatorFunctional":{"schemaItemType":"EntityClass","label":"Voltage Regulator","baseClass":"PowerSystemResourcesFunctional.RegulatingConductingEqFunctional"},"ShuntCapacitorFunctional":{"schemaItemType":"EntityClass","label":"Shunt Capacitor","description":"Single capacitor unit used to inject reactive power (positive Q) to improve voltage ","baseClass":"PowerSystemResourcesFunctional.ShuntCompensatorFunctional"},"ShuntCapacitorBankFunctional":{"schemaItemType":"EntityClass","label":"Shunt Capacitor Bank","description":"Group of capacitor units connected in series/parallel; often switchable in steps \r ","baseClass":"PowerSystemResourcesFunctional.ShuntCompensatorFunctional"},"ShuntReactorFunctional":{"schemaItemType":"EntityClass","label":"Shunt Reactor","baseClass":"PowerSystemResourcesFunctional.ShuntCompensatorFunctional"},"ShuntReactorBankFunctional":{"schemaItemType":"EntityClass","label":"Shunt Reactor Bank","baseClass":"PowerSystemResourcesFunctional.ShuntCompensatorFunctional"},"RectifierFunctional":{"schemaItemType":"EntityClass","label":"Rectifier","baseClass":"PowerSystemResourcesFunctional.PowerElectronicsConnectionFunctional"},"InverterFunctional":{"schemaItemType":"EntityClass","label":"Inverter","baseClass":"PowerSystemResourcesFunctional.PowerElectronicsConnectionFunctional"},"GroundingRodFunctional":{"schemaItemType":"EntityClass","label":"Grounding Rod","baseClass":"PowerSystemResourcesFunctional.GroundFunctional"},"GroundingGridFunctional":{"schemaItemType":"EntityClass","label":"Grounding Grid","baseClass":"PowerSystemResourcesFunctional.GroundFunctional"},"GroundingClampsFunctional":{"schemaItemType":"EntityClass","label":"Grounding Clamps","baseClass":"PowerSystemResourcesFunctional.GroundFunctional"},"GroundingAccessoriesFunctional":{"schemaItemType":"EntityClass","label":"Grounding Accessories","baseClass":"PowerSystemResourcesFunctional.GroundFunctional"},"BushingFunctional":{"schemaItemType":"EntityClass","label":"Bushing","baseClass":"SubstationFunctional.OtherAuxiliaryFunctional"},"LineTunerFunctional":{"schemaItemType":"EntityClass","label":"Line Tuner","baseClass":"SubstationFunctional.OtherAuxiliaryFunctional"},"SurgeCounterFunctional":{"schemaItemType":"EntityClass","label":"Surge Counter","baseClass":"SubstationFunctional.OtherAuxiliaryFunctional"},"GuyStrainInsulatorFunctional":{"schemaItemType":"EntityClass","label":"Guy Strain Insulator","baseClass":"SubstationFunctional.OtherAuxiliaryFunctional"},"ArcHornFunctional":{"schemaItemType":"EntityClass","label":"Arc Horn","baseClass":"SubstationFunctional.OtherAuxiliaryFunctional"},"CoronaRingFunctional":{"schemaItemType":"EntityClass","label":"Corona Ring","baseClass":"SubstationFunctional.OtherAuxiliaryFunctional"},"AnnunciatorFunctional":{"schemaItemType":"EntityClass","label":"Annunciator","baseClass":"SubstationFunctional.OtherAuxiliaryFunctional"},"StatusIndicatorFunctional":{"schemaItemType":"EntityClass","label":"Status Indicator","baseClass":"SubstationFunctional.OtherAuxiliaryFunctional"},"FastenersFunctional":{"schemaItemType":"EntityClass","label":"Fasteners","baseClass":"PowerSystemResourcesFunctional.StructureFunctional"},"BoltFunctional":{"schemaItemType":"EntityClass","label":"Bolt","baseClass":"SubstationFunctional.FastenersFunctional"},"WasherFunctional":{"schemaItemType":"EntityClass","label":"Washer","baseClass":"SubstationFunctional.FastenersFunctional"},"NutsFunctional":{"schemaItemType":"EntityClass","label":"Nuts","baseClass":"SubstationFunctional.FastenersFunctional"},"ScrewFunctional":{"schemaItemType":"EntityClass","label":"Screw","baseClass":"SubstationFunctional.FastenersFunctional"},"LiftingLugsFunctional":{"schemaItemType":"EntityClass","label":"Lifting Lugs","baseClass":"SubstationFunctional.FastenersFunctional"},"SupportsFunctional":{"schemaItemType":"EntityClass","label":"Supports","baseClass":"PowerSystemResourcesFunctional.StructureFunctional"},"BusSupportFunctional":{"schemaItemType":"EntityClass","label":"Bus Support","baseClass":"SubstationFunctional.SupportsFunctional"},"BracketFunctional":{"schemaItemType":"EntityClass","label":"Bracket","baseClass":"SubstationFunctional.SupportsFunctional"},"UboltFunctional":{"schemaItemType":"EntityClass","label":"U-Bolt","baseClass":"SubstationFunctional.SupportsFunctional"},"MountingKitFunctional":{"schemaItemType":"EntityClass","label":"Mounting Kit","description":"Additional components needed to mount equipment","baseClass":"SubstationFunctional.SupportsFunctional"},"PlatformFunctional":{"schemaItemType":"EntityClass","label":"Platform","baseClass":"PowerSystemResourcesFunctional.FoundationFunctional"},"WalkingPlatformFunctional":{"schemaItemType":"EntityClass","label":"Walking platform","baseClass":"SubstationFunctional.PlatformFunctional"},"SwitchOperatorPlatformFunctional":{"schemaItemType":"EntityClass","label":"Switch Operator Platform","baseClass":"SubstationFunctional.PlatformFunctional"},"EquipmentFoundationFunctional":{"schemaItemType":"EntityClass","label":"Equipment Foundation","baseClass":"PowerSystemResourcesFunctional.FoundationFunctional"},"StructureFoundationFunctional":{"schemaItemType":"EntityClass","label":"Structure Foundation","baseClass":"PowerSystemResourcesFunctional.FoundationFunctional"},"ElectricalBuildingFunctional":{"schemaItemType":"EntityClass","label":"Electrical Building","baseClass":"SubstationFunctional.SubstationFunctional"},"LVSwitchFunctional":{"schemaItemType":"EntityClass","label":"LV Switches","baseClass":"SubstationFunctional.ElectricalBuildingFunctional"},"AudioVisualDeviceFunctional":{"schemaItemType":"EntityClass","label":"Audio Visual Device","baseClass":"SubstationFunctional.ElectricalBuildingFunctional"},"CommunicationDeviceFunctional":{"schemaItemType":"EntityClass","label":"Communication Device","baseClass":"SubstationFunctional.ElectricalBuildingFunctional"},"ElectricPanelFunctional":{"schemaItemType":"EntityClass","label":"Electric Panel","baseClass":"SubstationFunctional.ElectricalBuildingFunctional"},"LVBatteryFunctional":{"schemaItemType":"EntityClass","label":"Low Voltage Battery","description":"A device in which electrical energy is stored and from which energy may be progressively released.","baseClass":"SubstationFunctional.ElectricalBuildingFunctional"},"ConditionerDeviceFunctional":{"schemaItemType":"EntityClass","label":"Conditioner Device","description":"used to remove unwanted matter from an electric or electronic signal","baseClass":"SubstationFunctional.ElectricalBuildingFunctional"},"ElectricLoadTimeControlFunctional":{"schemaItemType":"EntityClass","label":"Electric Load Time Control","description":"A device that applies control to the provision or flow of electrical energy over time ","baseClass":"SubstationFunctional.ElectricalBuildingFunctional"},"PowerOutletFunctional":{"schemaItemType":"EntityClass","label":"Outlet","baseClass":"SubstationFunctional.ElectricalBuildingFunctional"},"FanFunctional":{"schemaItemType":"EntityClass","label":"Fan","baseClass":"SubstationFunctional.ElectricalBuildingFunctional"},"LightingFixtureFunctional":{"schemaItemType":"EntityClass","label":"Lighting Fixture","baseClass":"SubstationFunctional.ElectricalBuildingFunctional"},"PowerBatteryFunctional":{"schemaItemType":"EntityClass","label":"Power Battery","baseClass":"SubstationFunctional.ElectricalBuildingFunctional"},"EnclosureFunctional":{"schemaItemType":"EntityClass","label":"Enclosure","baseClass":"SubstationFunctional.ElectricalBuildingFunctional"},"SolarDeviceFunctional":{"schemaItemType":"EntityClass","label":"Solar Device","baseClass":"SubstationFunctional.ElectricalBuildingFunctional"},"RacewayFunctional":{"schemaItemType":"EntityClass","label":"Raceway","baseClass":"SubstationFunctional.SubstationFunctional"},"CoverFunctional":{"schemaItemType":"EntityClass","label":"Cover","baseClass":"SubstationFunctional.EnclosureFunctional"},"CabinetFunctional":{"schemaItemType":"EntityClass","label":"Cabinet","baseClass":"SubstationFunctional.EnclosureFunctional"},"GasketFunctional":{"schemaItemType":"EntityClass","label":"Gasket","baseClass":"SubstationFunctional.EnclosureFunctional"},"SecondaryCutOutFunctional":{"schemaItemType":"EntityClass","label":"Secondary Cut Out","baseClass":"SubstationFunctional.EnclosureFunctional"},"PanelboardAssemblyFunctional":{"schemaItemType":"EntityClass","label":"Panel Board Assembly","baseClass":"SubstationFunctional.EnclosureFunctional"},"PullBoxFunctional":{"schemaItemType":"EntityClass","label":"Pull Box","baseClass":"SubstationFunctional.EnclosureFunctional"},"JunctionBoxFunctional":{"schemaItemType":"EntityClass","label":"Junction Box","description":"A point where one or more conducting equipments are connected with zero resistance.","baseClass":"SubstationFunctional.EnclosureFunctional"},"OutletBodyFunctional":{"schemaItemType":"EntityClass","label":"Outlet Body","baseClass":"SubstationFunctional.EnclosureFunctional"},"CableTrenchFunctional":{"schemaItemType":"EntityClass","label":"Cable Trench","baseClass":"SubstationFunctional.RacewayFunctional"},"DuctbankFunctional":{"schemaItemType":"EntityClass","label":"Duct bank","baseClass":"SubstationFunctional.RacewayFunctional"},"CableTrayFunctional":{"schemaItemType":"EntityClass","label":"Cable Tray","baseClass":"SubstationFunctional.RacewayFunctional"},"CableLadderFunctional":{"schemaItemType":"EntityClass","label":"Cable Ladder","baseClass":"SubstationFunctional.RacewayFunctional"},"CableLadderFittingFunctional":{"schemaItemType":"EntityClass","label":"Cable Ladder Fitting","baseClass":"SubstationFunctional.RacewayFunctional"},"CableTrayFittingsFunctional":{"schemaItemType":"EntityClass","label":"Cable Tray Fittings","baseClass":"SubstationFunctional.RacewayFunctional"},"CableTrayCoverFunctional":{"schemaItemType":"EntityClass","label":"Cable Tray Cover","baseClass":"SubstationFunctional.RacewayFunctional"},"WirewayFunctional":{"schemaItemType":"EntityClass","label":"Wireway","baseClass":"SubstationFunctional.RacewayFunctional"},"ConduitFittingFunctional":{"schemaItemType":"EntityClass","label":"Conduit Fittings","baseClass":"SubstationFunctional.RacewayFunctional"},"ConduitFunctional":{"schemaItemType":"EntityClass","label":"Conduit","baseClass":"SubstationFunctional.RacewayFunctional"},"MiscellaneousFunctional":{"schemaItemType":"EntityClass","label":"Miscellaneous","baseClass":"SubstationFunctional.SubstationFunctional"},"FenceFunctional":{"schemaItemType":"EntityClass","label":"Fence","baseClass":"SubstationFunctional.MiscellaneousFunctional"},"GateFunctional":{"schemaItemType":"EntityClass","label":"Gate","baseClass":"SubstationFunctional.MiscellaneousFunctional"},"ControlBuildingFunctional":{"schemaItemType":"EntityClass","label":"Control Building","baseClass":"SubstationFunctional.MiscellaneousFunctional"},"OilContainmentSystemFunctional":{"schemaItemType":"EntityClass","label":"Oil Containment System","baseClass":"SubstationFunctional.MiscellaneousFunctional"},"PhysicalSafetyBarrierFunctional":{"schemaItemType":"EntityClass","label":"Physical Safety Barrier","baseClass":"SubstationFunctional.MiscellaneousFunctional"},"GeneralHardwareFunctional":{"schemaItemType":"EntityClass","label":"General Hardware","baseClass":"SubstationFunctional.MiscellaneousFunctional"},"NameplateFunctional":{"schemaItemType":"EntityClass","label":"Nameplate","description":"Mounted on the equipment, and contains most relevant equipment attributes. Can be provided by manufacturer or created by utility using the data from design.","baseClass":"SubstationFunctional.MiscellaneousFunctional"},"TerrainFunctional":{"schemaItemType":"EntityClass","label":"Terrain","description":"DTM Terrain","baseClass":"SubstationFunctional.MiscellaneousFunctional"},"AnimalGuardFunctional":{"schemaItemType":"EntityClass","label":"Animal Guard","baseClass":"SubstationFunctional.PhysicalSafetyBarrierFunctional"},"FireBarrierFunctional":{"schemaItemType":"EntityClass","label":"Fire Barrier","baseClass":"SubstationFunctional.PhysicalSafetyBarrierFunctional"},"VehicleBarrierFunctional":{"schemaItemType":"EntityClass","label":"Vehicle Barrier","baseClass":"SubstationFunctional.PhysicalSafetyBarrierFunctional"}}}
|
|
@@ -11,7 +11,7 @@
|
|
|
11
11
|
<ECSchemaReference name="BisCustomAttributes" version="01.00.00" alias="bisCA" />
|
|
12
12
|
<ECCustomAttributes>
|
|
13
13
|
<ProductionStatus xmlns="CoreCustomAttributes.01.00.04">
|
|
14
|
-
<SupportedUse>
|
|
14
|
+
<SupportedUse>FieldTesting</SupportedUse>
|
|
15
15
|
</ProductionStatus>
|
|
16
16
|
<SchemaLayerInfo xmlns="BisCustomAttributes.01.00.00">
|
|
17
17
|
<Value>Application</Value>
|