@bentley/substation-functional-custom-schema 1.0.5-dev.1
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
package/LICENSE.md
ADDED
|
@@ -0,0 +1,9 @@
|
|
|
1
|
+
# MIT License
|
|
2
|
+
|
|
3
|
+
Copyright © 2017-2026 Bentley Systems, Incorporated. All rights reserved.
|
|
4
|
+
|
|
5
|
+
Permission is hereby granted, free of charge, to any person obtaining a copy of this software and associated documentation files (the "Software"), to deal in the Software without restriction, including without limitation the rights to use, copy, modify, merge, publish, distribute, sublicense, and/or sell copies of the Software, and to permit persons to whom the Software is furnished to do so, subject to the following conditions:
|
|
6
|
+
|
|
7
|
+
The above copyright notice and this permission notice shall be included in all copies or substantial portions of the Software.
|
|
8
|
+
|
|
9
|
+
THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.
|
package/README.md
ADDED
|
@@ -0,0 +1,9 @@
|
|
|
1
|
+
# @bentley/substation-functional-custom-schema
|
|
2
|
+
|
|
3
|
+
Copyright © Bentley Systems, Incorporated. All rights reserved. See [LICENSE.md](./LICENSE.md) for license terms and full copyright notice.
|
|
4
|
+
|
|
5
|
+
[iTwin.js](http://itwinjs.org) is an open source platform for creating, querying, modifying, and displaying Infrastructure Digital Twins.
|
|
6
|
+
|
|
7
|
+
## BIS Schemas
|
|
8
|
+
|
|
9
|
+
The acronym “BIS” stands for “Base Infrastructure Schemas”. BIS is an “open” and extensible family of schemas that is modularized into Domains. Please go to [iTwinjs.org](https://www.itwinjs.org/bis/) for more information.
|
|
@@ -0,0 +1 @@
|
|
|
1
|
+
{"$schema":"https://dev.bentley.com/json_schemas/ec/32/ecschema","name":"SubstationFunctionalCustom","version":"01.00.05","alias":"subfuncc","label":"SubstationFunctionalCustom","description":"This schema contains classes used for Substation Design.","references":[{"name":"BisCore","version":"01.00.26"},{"name":"PowerSystemResourcesFunctional","version":"01.00.01"},{"name":"SubstationFunctional","version":"01.00.05"},{"name":"CoreCustomAttributes","version":"01.00.05"},{"name":"BisCustomAttributes","version":"01.00.00"}],"customAttributes":[{"className":"CoreCustomAttributes.DynamicSchema"},{"className":"CoreCustomAttributes.ProductionStatus","SupportedUse":"NotForProduction"},{"className":"BisCustomAttributes.SchemaLayerInfo","Value":"Application"}],"items":{"EquipmentCustomFunctionalAspect":{"schemaItemType":"EntityClass","label":"Equipment Functional Aspect","description":"Contains properties of an FunctionalAspect.","baseClass":"PowerSystemResourcesFunctional.EquipmentFunctionalAspect","properties":[{"name":"IsUsingSharedDeviceId","type":"PrimitiveProperty","label":"Is Using Shared Device Id","typeName":"boolean"},{"name":"DesignWorkOrderNumber","type":"PrimitiveProperty","label":"Design Work Order Number","typeName":"string"},{"name":"Location","type":"PrimitiveProperty","label":"Location","typeName":"string"},{"name":"Installation","type":"PrimitiveProperty","label":"Installation","typeName":"string"},{"name":"BOMDocumentVersion","type":"PrimitiveProperty","label":"BOM Document Version","typeName":"string"},{"name":"DesignRevisionNumber","type":"PrimitiveProperty","label":"Design Revision Number","typeName":"string"},{"name":"SubstationName","type":"PrimitiveProperty","label":"Substation Name","typeName":"string"},{"name":"SubstationIdentifier","type":"PrimitiveProperty","label":"Substation Identifier","typeName":"string"}]},"StructureCustomFunctionalAspect":{"schemaItemType":"EntityClass","label":"Structure Functional Aspect","description":"Contains properties of an FunctionalAspect.","baseClass":"PowerSystemResourcesFunctional.StructureFunctionalAspect","properties":[{"name":"IsUsingSharedDeviceId","type":"PrimitiveProperty","label":"Is Using Shared Device Id","typeName":"boolean"},{"name":"DesignWorkOrderNumber","type":"PrimitiveProperty","label":"Design Work Order Number","typeName":"string"},{"name":"Location","type":"PrimitiveProperty","label":"Location","typeName":"string"},{"name":"Installation","type":"PrimitiveProperty","label":"Installation","typeName":"string"},{"name":"BOMDocumentVersion","type":"PrimitiveProperty","label":"BOM Document Version","typeName":"string"},{"name":"DesignRevisionNumber","type":"PrimitiveProperty","label":"Design Revision Number","typeName":"string"},{"name":"SubstationName","type":"PrimitiveProperty","label":"Substation Name","typeName":"string"},{"name":"SubstationIdentifier","type":"PrimitiveProperty","label":"Substation Identifier","typeName":"string"}]},"FoundationCustomFunctionalAspect":{"schemaItemType":"EntityClass","label":"Foundation Functional Aspect","description":"Contains properties of an FunctionalAspect.","baseClass":"PowerSystemResourcesFunctional.FoundationFunctionalAspect","properties":[{"name":"IsUsingSharedDeviceId","type":"PrimitiveProperty","label":"Is Using Shared Device Id","typeName":"boolean"},{"name":"DesignWorkOrderNumber","type":"PrimitiveProperty","label":"Design Work Order Number","typeName":"string"},{"name":"Location","type":"PrimitiveProperty","label":"Location","typeName":"string"},{"name":"Installation","type":"PrimitiveProperty","label":"Installation","typeName":"string"},{"name":"BOMDocumentVersion","type":"PrimitiveProperty","label":"BOM Document Version","typeName":"string"},{"name":"DesignRevisionNumber","type":"PrimitiveProperty","label":"Design Revision Number","typeName":"string"},{"name":"SubstationName","type":"PrimitiveProperty","label":"Substation Name","typeName":"string"},{"name":"SubstationIdentifier","type":"PrimitiveProperty","label":"Substation Identifier","typeName":"string"}]},"SubstationCustomFunctionalAspect":{"schemaItemType":"EntityClass","label":"Substation Functional Aspect","description":"Contains properties of an FunctionalAspect.","baseClass":"SubstationFunctional.SubstationFunctionalAspect","properties":[{"name":"IsUsingSharedDeviceId","type":"PrimitiveProperty","label":"Is Using Shared Device Id","typeName":"boolean"},{"name":"DesignWorkOrderNumber","type":"PrimitiveProperty","label":"Design Work Order Number","typeName":"string"},{"name":"Location","type":"PrimitiveProperty","label":"Location","typeName":"string"},{"name":"Installation","type":"PrimitiveProperty","label":"Installation","typeName":"string"},{"name":"BOMDocumentVersion","type":"PrimitiveProperty","label":"BOM Document Version","typeName":"string"},{"name":"DesignRevisionNumber","type":"PrimitiveProperty","label":"Design Revision Number","typeName":"string"},{"name":"SubstationName","type":"PrimitiveProperty","label":"Substation Name","typeName":"string"},{"name":"SubstationIdentifier","type":"PrimitiveProperty","label":"Substation Identifier","typeName":"string"}]},"EquipmentFunctionalOwnsEquipmentCustomFunctionalAspect":{"schemaItemType":"RelationshipClass","modifier":"None","baseClass":"BisCore.ElementOwnsUniqueAspect","strength":"Embedding","strengthDirection":"Forward","source":{"multiplicity":"(1..1)","roleLabel":"owns","polymorphic":true,"constraintClasses":["PowerSystemResourcesFunctional.EquipmentFunctional"]},"target":{"multiplicity":"(0..*)","roleLabel":"is owned by","polymorphic":true,"constraintClasses":["SubstationFunctionalCustom.EquipmentCustomFunctionalAspect"]}},"StructureFunctionalOwnsStructureCustomFunctionalAspect":{"schemaItemType":"RelationshipClass","modifier":"None","baseClass":"BisCore.ElementOwnsUniqueAspect","strength":"Embedding","strengthDirection":"Forward","source":{"multiplicity":"(1..1)","roleLabel":"owns","polymorphic":true,"constraintClasses":["PowerSystemResourcesFunctional.StructureFunctional"]},"target":{"multiplicity":"(0..*)","roleLabel":"is owned by","polymorphic":true,"constraintClasses":["SubstationFunctionalCustom.StructureCustomFunctionalAspect"]}},"FoundationFunctionalOwnsFoundationCustomFunctionalAspect":{"schemaItemType":"RelationshipClass","modifier":"None","baseClass":"BisCore.ElementOwnsUniqueAspect","strength":"Embedding","strengthDirection":"Forward","source":{"multiplicity":"(1..1)","roleLabel":"owns","polymorphic":true,"constraintClasses":["PowerSystemResourcesFunctional.FoundationFunctional"]},"target":{"multiplicity":"(0..*)","roleLabel":"is owned by","polymorphic":true,"constraintClasses":["SubstationFunctionalCustom.FoundationCustomFunctionalAspect"]}},"SubstationFunctionalOwnsSubstationCustomFunctionalAspect":{"schemaItemType":"RelationshipClass","modifier":"None","baseClass":"BisCore.ElementOwnsUniqueAspect","strength":"Embedding","strengthDirection":"Forward","source":{"multiplicity":"(1..1)","roleLabel":"owns","polymorphic":true,"constraintClasses":["SubstationFunctional.SubstationFunctional"]},"target":{"multiplicity":"(0..*)","roleLabel":"is owned by","polymorphic":true,"constraintClasses":["SubstationFunctionalCustom.SubstationCustomFunctionalAspect"]}},"SwitchFunctionalAspect":{"schemaItemType":"EntityClass","label":"Switch","description":"A generic device designed to close, or open, or both, one or more electric circuits. All switches are two terminal devices including grounding switches. The ACDCTerminal.connected at the two sides of the switch shall not be considered for assessing switch connectivity, i.e. only Switch.open, .normalOpen and .locked are relevant.","baseClass":"SubstationFunctionalCustom.EquipmentCustomFunctionalAspect","properties":[{"name":"Phase","type":"PrimitiveProperty","label":"Phase","typeName":"string"}]},"SectionalizerFunctionalAspect":{"schemaItemType":"EntityClass","label":"Sectionalizer","description":"Automatic switch that will lock open to isolate a faulted section. It may, or may not, have load breaking capability. Its primary purpose is to provide fault sectionalising at locations where the fault current is either too high, or too low, for proper coordination of fuses.","baseClass":"SubstationFunctionalCustom.SwitchFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"}]},"CutFunctionalAspect":{"schemaItemType":"EntityClass","label":"Cut","description":"A cut separates a line segment into two parts. The cut appears as a switch inserted between these two parts and connects them together. As the cut is normally open there is no galvanic connection between the two line segment parts. But it is possible to close the cut to get galvanic connection.\r The cut terminals are oriented towards the line segment terminals with the same sequence number. Hence the cut terminal with sequence number equal to 1 is oriented to the line segment's terminal with sequence number equal to 1.\r The cut terminals also act as connection points for jumpers and other equipment, e.g. a mobile generator. To enable this, connectivity nodes are placed at the cut terminals. Once the connectivity nodes are in place any conducting equipment can be connected at them.","baseClass":"SubstationFunctionalCustom.SwitchFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"}]},"JumperFunctionalAspect":{"schemaItemType":"EntityClass","label":"Jumper","description":"A short section of conductor with negligible impedance which can be manually removed and replaced if the circuit is de-energized. Note that zero-impedance branches can potentially be modelled by other equipment types.","baseClass":"SubstationFunctionalCustom.SwitchFunctionalAspect"},"FuseFunctionalAspect":{"schemaItemType":"EntityClass","label":"Fuse","description":"An overcurrent protective device with a circuit opening fusible part that is heated and severed by the passage of overcurrent through it. A fuse is considered a switching device because it breaks current.","baseClass":"SubstationFunctionalCustom.SwitchFunctionalAspect"},"GroundDisconnectorFunctionalAspect":{"schemaItemType":"EntityClass","label":"Ground Disconnector","description":"A manually operated or motor operated mechanical switching device used for isolating a circuit or equipment from ground.\r Also known as earthing switch","baseClass":"SubstationFunctionalCustom.SwitchFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"}]},"DisconnectorFunctionalAspect":{"schemaItemType":"EntityClass","label":"Disconnector","description":"A manually operated or motor operated mechanical switching device used for changing the connections in a circuit, or for isolating a circuit or equipment from a source of power. It is required to open or close circuits when negligible current is broken or made.","baseClass":"SubstationFunctionalCustom.SwitchFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"}]},"ProtectedSwitchFunctionalAspect":{"schemaItemType":"EntityClass","label":"Protected Switch","description":"A ProtectedSwitch is a switching device that can be operated by ProtectionEquipment.\r ","baseClass":"SubstationFunctionalCustom.SwitchFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"}]},"AuxiliaryEquipmentFunctionalAspect":{"schemaItemType":"EntityClass","label":"Auxiliary Equipment","description":"AuxiliaryEquipment describe equipment that is not performing any primary functions but support for the equipment performing the primary function.\r AuxiliaryEquipment is attached to primary equipment via an association with Terminal.","baseClass":"SubstationFunctionalCustom.EquipmentCustomFunctionalAspect"},"BreakerFunctionalAspect":{"schemaItemType":"EntityClass","label":"Breaker","baseClass":"SubstationFunctionalCustom.ProtectedSwitchFunctionalAspect"},"RecloserFunctionalAspect":{"schemaItemType":"EntityClass","label":"Recloser","description":"Pole-mounted fault interrupter with built-in phase and ground relays, current transformer (CT), and supplemental controls.","baseClass":"SubstationFunctionalCustom.ProtectedSwitchFunctionalAspect"},"LoadBreakSwitchFunctionalAspect":{"schemaItemType":"EntityClass","label":"Load Break Switch","description":"A mechanical switching device capable of making, carrying, and breaking currents under normal operating conditions.","baseClass":"SubstationFunctionalCustom.ProtectedSwitchFunctionalAspect"},"SurgeArresterFunctionalAspect":{"schemaItemType":"EntityClass","label":"Surge Arrester","description":"Shunt device, installed on the network, usually in the proximity of electrical equipment in order to protect the said equipment against transient voltage transients caused by lightning or switching activity.","baseClass":"SubstationFunctionalCustom.AuxiliaryEquipmentFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"}]},"FaultIndicatorFunctionalAspect":{"schemaItemType":"EntityClass","label":"Fault Indicator","description":"A FaultIndicator is typically only an indicator (which may or may not be remotely monitored), and not a piece of equipment that actually initiates a protection event. It is used for FLISR (Fault Location, Isolation and Restoration) purposes, assisting with the dispatch of crews to \"most likely\" part of the network (i.e. assists with determining circuit section where the fault most likely happened).","baseClass":"SubstationFunctionalCustom.AuxiliaryEquipmentFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"}]},"WaveTrapFunctionalAspect":{"schemaItemType":"EntityClass","label":"Wave Trap","description":"Line traps are devices that impede high frequency power line carrier signals yet present a negligible impedance at the main power frequency.","baseClass":"SubstationFunctionalCustom.AuxiliaryEquipmentFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"}]},"InsulatorFunctionalAspect":{"schemaItemType":"EntityClass","label":"Insulator","baseClass":"SubstationFunctionalCustom.AuxiliaryEquipmentFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"},{"name":"Phase","type":"PrimitiveProperty","label":"Phase","typeName":"string"}]},"SensorFunctionalAspect":{"schemaItemType":"EntityClass","label":"Sensor","description":"AuxiliaryEquipment describes equipment that does not perform primary functions but supports equipment that does.","baseClass":"SubstationFunctionalCustom.AuxiliaryEquipmentFunctionalAspect"},"EarthFaultCompensatorFunctionalAspect":{"schemaItemType":"EntityClass","label":"Earth Fault Compensator","description":"A conducting equipment used to represent a connection to ground which is typically used to compensate earth faults. An earth fault compensator device modelled with a single terminal implies a second terminal solidly connected to ground. If two terminals are modelled, the ground is not assumed and normal connection rules apply.\r ","baseClass":"SubstationFunctionalCustom.EquipmentCustomFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"}]},"DisconnectingCircuitBreakerFunctionalAspect":{"schemaItemType":"EntityClass","label":"Circuit Breaker With Disconnector","description":"A circuit breaking device including disconnecting function, eliminating the need for separate disconnectors.","baseClass":"SubstationFunctionalCustom.BreakerFunctionalAspect"},"PotentialTransformerFunctionalAspect":{"schemaItemType":"EntityClass","label":"Potential Transformer","description":"AuxiliaryEquipment describe equipment that is not performing any primary functions but support for the equipment performing the primary function.\r AuxiliaryEquipment is attached to primary equipment via an association with Terminal.","baseClass":"SubstationFunctionalCustom.SensorFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"},{"name":"Phase","type":"PrimitiveProperty","label":"Phase","typeName":"string"},{"name":"PTRatioUsed","type":"PrimitiveProperty","label":"PT Ratio Used","typeName":"string"}]},"CurrentTransformerFunctionalAspect":{"schemaItemType":"EntityClass","label":"Current Transformer","baseClass":"SubstationFunctionalCustom.SensorFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"},{"name":"Phase","type":"PrimitiveProperty","label":"Phase","typeName":"string"},{"name":"CTRatioUsed","type":"PrimitiveProperty","label":"CT Ratio Used","typeName":"string"}]},"PostLineSensorFunctionalAspect":{"schemaItemType":"EntityClass","label":"Post Line Sensor","description":"A sensor used mainly in overhead distribution networks as the source of both current and voltage measurements","baseClass":"SubstationFunctionalCustom.SensorFunctionalAspect"},"GroundingImpedanceFunctionalAspect":{"schemaItemType":"EntityClass","label":"Grounding Impedance","description":"A fixed impedance device used for grounding.\r ","baseClass":"SubstationFunctionalCustom.EarthFaultCompensatorFunctionalAspect","properties":[{"name":"Phase","type":"PrimitiveProperty","label":"Phase","typeName":"string"},{"name":"R","type":"PrimitiveProperty","label":"Resistance","typeName":"string"},{"name":"X","type":"PrimitiveProperty","label":"Reactance","typeName":"string"}]},"PetersenCoilFunctionalAspect":{"schemaItemType":"EntityClass","label":"Petersen Coil","description":"A variable impedance device normally used to offset line charging during single line faults in an ungrounded section of network.","baseClass":"SubstationFunctionalCustom.EarthFaultCompensatorFunctionalAspect"},"TransformerFunctionalAspect":{"schemaItemType":"EntityClass","label":"Transformer","description":"Power transformers are utilized in transmission networks with significantly higher voltage, while distribution transformers function in distribution networks defined by lower voltages","baseClass":"SubstationFunctionalCustom.EquipmentCustomFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"}]},"PowerTransformerFunctionalAspect":{"schemaItemType":"EntityClass","label":"Power Transformer","baseClass":"SubstationFunctionalCustom.TransformerFunctionalAspect"},"CompensatorFunctionalAspect":{"schemaItemType":"EntityClass","label":"Compensator","description":"A Series Compensator is a series capacitor or reactor or an AC transmission line without charging susceptance. It is a two terminal device.","baseClass":"SubstationFunctionalCustom.EquipmentCustomFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"},{"name":"R","type":"PrimitiveProperty","label":"Resistance","typeName":"string"},{"name":"X","type":"PrimitiveProperty","label":"Reactance","typeName":"string"}]},"SeriesCompensatorFunctionalAspect":{"schemaItemType":"EntityClass","label":"Series Compensator","description":"A Series Compensator is a series capacitor or reactor or an AC transmission line without charging susceptance. It is a two terminal device.","baseClass":"SubstationFunctionalCustom.CompensatorFunctionalAspect"},"ConductorFunctionalAspect":{"schemaItemType":"EntityClass","label":"Conductor","baseClass":"SubstationFunctionalCustom.EquipmentCustomFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"},{"name":"Phase","type":"PrimitiveProperty","label":"Phase","typeName":"string"},{"name":"R","type":"PrimitiveProperty","label":"Resistance","typeName":"string"},{"name":"X","type":"PrimitiveProperty","label":"Reactance","typeName":"string"}]},"ClampFunctionalAspect":{"schemaItemType":"EntityClass","label":"Clamp","baseClass":"SubstationFunctionalCustom.EquipmentCustomFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"},{"name":"Phase","type":"PrimitiveProperty","label":"Phase","typeName":"string"}]},"ConnectorFunctionalAspect":{"schemaItemType":"EntityClass","label":"Connector","description":"A conductor, or group of conductors, with negligible impedance, that serve to connect other conducting equipment within a single substation and are modelled with a single logical terminal.","baseClass":"SubstationFunctionalCustom.EquipmentCustomFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"},{"name":"Phase","type":"PrimitiveProperty","label":"Phase","typeName":"string"}]},"BusbarSectionFunctionalAspect":{"schemaItemType":"EntityClass","label":"Busbar Section","description":"A conductor, or group of conductors, with negligible impedance, that serve to connect other conducting equipment within a single substation. \r Voltage measurements are typically obtained from voltage transformers that are connected to busbar sections. A bus bar section may have many physical terminals but for analysis is modelled with exactly one logical terminal.","baseClass":"SubstationFunctionalCustom.ConnectorFunctionalAspect"},"JunctionFunctionalAspect":{"schemaItemType":"EntityClass","label":"Junction","description":"A point where one or more conducting equipments are connected with zero resistance.\r ","baseClass":"SubstationFunctionalCustom.ConnectorFunctionalAspect"},"EnergyConnectionFunctionalAspect":{"schemaItemType":"EntityClass","label":"Energy Connection","baseClass":"SubstationFunctionalCustom.EquipmentCustomFunctionalAspect"},"EnergySourceFunctionalAspect":{"schemaItemType":"EntityClass","label":"Energy Source","baseClass":"SubstationFunctionalCustom.EnergyConnectionFunctionalAspect"},"EnergyConsumerFunctionalAspect":{"schemaItemType":"EntityClass","label":"Energy Consumer","baseClass":"SubstationFunctionalCustom.EnergyConnectionFunctionalAspect"},"RegulatingConductingEqFunctionalAspect":{"schemaItemType":"EntityClass","label":"Regulating Conducting Equipment","baseClass":"SubstationFunctionalCustom.EnergyConnectionFunctionalAspect"},"GroundFunctionalAspect":{"schemaItemType":"EntityClass","label":"Grounding Equipment","baseClass":"SubstationFunctionalCustom.EquipmentCustomFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"}]},"FrequencyConverterFunctionalAspect":{"schemaItemType":"EntityClass","label":"Frequency Converter","description":"A device to convert from one frequency to another (e.g., frequency F1 to F2) comprises a pair of FrequencyConverter instances. One converts from F1 to DC, the other converts the DC to F2.","baseClass":"SubstationFunctionalCustom.RegulatingConductingEqFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"}]},"StaticVarCompensatorFunctionalAspect":{"schemaItemType":"EntityClass","label":"Static Var Compensator","description":"A facility for providing variable and controllable shunt reactive power. The SVC typically consists of a stepdown transformer, filter, thyristor-controlled reactor, and thyristor-switched capacitor arms.\r \r The SVC may operate in fixed MVar output mode or in voltage control mode. When in voltage control mode, the output of the SVC will be proportional to the deviation of voltage at the controlled bus from the voltage setpoint. The SVC characteristic slope defines the proportion. If the voltage at the controlled bus is equal to the voltage setpoint, the SVC MVar output is zero.","baseClass":"SubstationFunctionalCustom.RegulatingConductingEqFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"},{"name":"R","type":"PrimitiveProperty","label":"Resistance","typeName":"string"},{"name":"X","type":"PrimitiveProperty","label":"Reactance","typeName":"string"}]},"ExternalNetworkInjectionFunctionalAspect":{"schemaItemType":"EntityClass","label":"External Network Injection","baseClass":"SubstationFunctionalCustom.RegulatingConductingEqFunctionalAspect"},"ShuntCompensatorFunctionalAspect":{"schemaItemType":"EntityClass","label":"Shunt Compensator","baseClass":"SubstationFunctionalCustom.RegulatingConductingEqFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"},{"name":"Phase","type":"PrimitiveProperty","label":"Phase","typeName":"string"},{"name":"R","type":"PrimitiveProperty","label":"Resistance","typeName":"string"},{"name":"X","type":"PrimitiveProperty","label":"Reactance","typeName":"string"}]},"PowerElectronicsConnectionFunctionalAspect":{"schemaItemType":"EntityClass","label":"Power Electronic Connection","baseClass":"SubstationFunctionalCustom.RegulatingConductingEqFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"},{"name":"Phase","type":"PrimitiveProperty","label":"Phase","typeName":"string"}]},"RotatingMachineFunctionalAspect":{"schemaItemType":"EntityClass","label":"Rotating Machine","baseClass":"SubstationFunctionalCustom.RegulatingConductingEqFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"}]},"DERFunctionalAspect":{"schemaItemType":"EntityClass","label":"DER","baseClass":"SubstationFunctionalCustom.EquipmentCustomFunctionalAspect"},"AsynchronousMachineFunctionalAspect":{"schemaItemType":"EntityClass","label":"Asynchronous Machine","baseClass":"SubstationFunctionalCustom.RotatingMachineFunctionalAspect"},"SynchronousMachineFunctionalAspect":{"schemaItemType":"EntityClass","label":"Synchronous Machine","baseClass":"SubstationFunctionalCustom.RotatingMachineFunctionalAspect"},"BatteryFunctionalAspect":{"schemaItemType":"EntityClass","label":"Battery","baseClass":"SubstationFunctionalCustom.DERFunctionalAspect"},"SolarPanelFunctionalAspect":{"schemaItemType":"EntityClass","label":"Solar Panel","baseClass":"SubstationFunctionalCustom.DERFunctionalAspect"},"WindTurbineFunctionalAspect":{"schemaItemType":"EntityClass","label":"Wind Turbine","baseClass":"SubstationFunctionalCustom.DERFunctionalAspect"},"LightningProtectionFunctionalAspect":{"schemaItemType":"EntityClass","label":"Lightning Protection","baseClass":"SubstationFunctionalCustom.EquipmentCustomFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"},{"name":"R","type":"PrimitiveProperty","label":"Resistance","typeName":"string"},{"name":"X","type":"PrimitiveProperty","label":"Reactance","typeName":"string"}]},"LightningMastsFunctionalAspect":{"schemaItemType":"EntityClass","label":"Lightning Masts","baseClass":"SubstationFunctionalCustom.LightningProtectionFunctionalAspect"},"ShieldWireFunctionalAspect":{"schemaItemType":"EntityClass","label":"Shield Wire","baseClass":"SubstationFunctionalCustom.LightningProtectionFunctionalAspect"},"OtherAuxiliaryFunctionalAspect":{"schemaItemType":"EntityClass","label":"Other Auxiliary","baseClass":"SubstationFunctionalCustom.AuxiliaryEquipmentFunctionalAspect"},"EMVTFunctionalAspect":{"schemaItemType":"EntityClass","label":"Electromagnetic Voltage Transformers","description":"Electromagnetic Voltage Transformers \r ","baseClass":"SubstationFunctionalCustom.PotentialTransformerFunctionalAspect"},"OVTFunctionalAspect":{"schemaItemType":"EntityClass","label":"Optical Voltage Transformers","description":"Optical Voltage Transformers \r ","baseClass":"SubstationFunctionalCustom.PotentialTransformerFunctionalAspect"},"CCVTFunctionalAspect":{"schemaItemType":"EntityClass","label":"Capacitive Coupled Voltage Transformer","baseClass":"SubstationFunctionalCustom.PotentialTransformerFunctionalAspect"},"CombinedCTVTFunctionalAspect":{"schemaItemType":"EntityClass","label":"Combined CT/VT ","baseClass":"SubstationFunctionalCustom.SensorFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"},{"name":"Phase","type":"PrimitiveProperty","label":"Phase","typeName":"string"},{"name":"CTRatioUsed","type":"PrimitiveProperty","label":"CT Ratio Used","typeName":"string"},{"name":"PTRatioUsed","type":"PrimitiveProperty","label":"PT Ratio Used","typeName":"string"}]},"NeutralGroundingResistorFunctionalAspect":{"schemaItemType":"EntityClass","label":"Neutral Grounding Resistor","baseClass":"SubstationFunctionalCustom.GroundingImpedanceFunctionalAspect"},"NeutralGroundingReactorFunctionalAspect":{"schemaItemType":"EntityClass","label":"Neutral Grounding Reactor","description":"The conductor used to connect the non-current-carrying metal parts of equipment, raceways and other enclosures to the system grounded conductor, grounding electrode conductor, or both, at the service equipment or at the source of a separately-derived system","baseClass":"SubstationFunctionalCustom.GroundingImpedanceFunctionalAspect"},"PowerTransformer2WindingsFunctionalAspect":{"schemaItemType":"EntityClass","label":"Power Transformer - 2 Windings","baseClass":"SubstationFunctionalCustom.PowerTransformerFunctionalAspect"},"PowerTransformer3WindingsFunctionalAspect":{"schemaItemType":"EntityClass","label":"Power Transformer - 3 Windings","baseClass":"SubstationFunctionalCustom.PowerTransformerFunctionalAspect"},"DistributionTransformerFunctionalAspect":{"schemaItemType":"EntityClass","label":"Distribution Transformer","baseClass":"SubstationFunctionalCustom.PowerTransformerFunctionalAspect"},"GroundingTransformerwithResistorFunctionalAspect":{"schemaItemType":"EntityClass","label":"Zigzag Grounding Transformer with Resistor","baseClass":"SubstationFunctionalCustom.PowerTransformerFunctionalAspect","properties":[{"name":"R","type":"PrimitiveProperty","label":"Resistance","typeName":"string"},{"name":"X","type":"PrimitiveProperty","label":"Reactance","typeName":"string"}]},"SeriesCapacitorFunctionalAspect":{"schemaItemType":"EntityClass","label":"Series Capacitor","baseClass":"SubstationFunctionalCustom.SeriesCompensatorFunctionalAspect"},"SeriesReactorFunctionalAspect":{"schemaItemType":"EntityClass","label":"Series Reactor","baseClass":"SubstationFunctionalCustom.SeriesCompensatorFunctionalAspect"},"TCSCFunctionalAspect":{"schemaItemType":"EntityClass","label":"Thyristor-Controlled Series Capacitor","baseClass":"SubstationFunctionalCustom.SeriesCompensatorFunctionalAspect"},"PowerCableFunctionalAspect":{"schemaItemType":"EntityClass","label":"Power Cable","baseClass":"SubstationFunctionalCustom.ConductorFunctionalAspect"},"InsulatedPowerCableFunctionalAspect":{"schemaItemType":"EntityClass","label":"Insulated Power Cable","baseClass":"SubstationFunctionalCustom.ConductorFunctionalAspect"},"CableClampsFunctionalAspect":{"schemaItemType":"EntityClass","label":"Cable Clamps","baseClass":"SubstationFunctionalCustom.ClampFunctionalAspect"},"BusClampsFunctionalAspect":{"schemaItemType":"EntityClass","label":"Bus Clamps","baseClass":"SubstationFunctionalCustom.ClampFunctionalAspect"},"CableConnectorFunctionalAspect":{"schemaItemType":"EntityClass","label":"Cable Connector","baseClass":"SubstationFunctionalCustom.JunctionFunctionalAspect"},"BusConnectorFunctionalAspect":{"schemaItemType":"EntityClass","label":"Bus Connector","baseClass":"SubstationFunctionalCustom.JunctionFunctionalAspect"},"BusAccessoriesFunctionalAspect":{"schemaItemType":"EntityClass","label":"Bus Accessories","baseClass":"SubstationFunctionalCustom.ConnectorFunctionalAspect"},"CableAccessoriesFunctionalAspect":{"schemaItemType":"EntityClass","label":"Cable Accessories","baseClass":"SubstationFunctionalCustom.ConnectorFunctionalAspect"},"LineHardwareFunctionalAspect":{"schemaItemType":"EntityClass","label":"Line Hardware","baseClass":"SubstationFunctionalCustom.ConnectorFunctionalAspect"},"VoltageRegulatorFunctionalAspect":{"schemaItemType":"EntityClass","label":"Voltage Regulator","baseClass":"SubstationFunctionalCustom.RegulatingConductingEqFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"},{"name":"Phase","type":"PrimitiveProperty","label":"Phase","typeName":"string"}]},"ShuntCapacitorFunctionalAspect":{"schemaItemType":"EntityClass","label":"Shunt Capacitor","description":"Single capacitor unit used to inject reactive power (positive Q) to improve voltage ","baseClass":"SubstationFunctionalCustom.ShuntCompensatorFunctionalAspect"},"ShuntCapacitorBankFunctionalAspect":{"schemaItemType":"EntityClass","label":"Shunt Capacitor Bank","description":"Group of capacitor units connected in series/parallel; often switchable in steps \r ","baseClass":"SubstationFunctionalCustom.ShuntCompensatorFunctionalAspect"},"ShuntReactorFunctionalAspect":{"schemaItemType":"EntityClass","label":"Shunt Reactor","baseClass":"SubstationFunctionalCustom.ShuntCompensatorFunctionalAspect"},"ShuntReactorBankFunctionalAspect":{"schemaItemType":"EntityClass","label":"Shunt Reactor Bank","baseClass":"SubstationFunctionalCustom.ShuntCompensatorFunctionalAspect"},"RectifierFunctionalAspect":{"schemaItemType":"EntityClass","label":"Rectifier","baseClass":"SubstationFunctionalCustom.PowerElectronicsConnectionFunctionalAspect"},"InverterFunctionalAspect":{"schemaItemType":"EntityClass","label":"Inverter","baseClass":"SubstationFunctionalCustom.PowerElectronicsConnectionFunctionalAspect"},"GroundingRodFunctionalAspect":{"schemaItemType":"EntityClass","label":"Grounding Rod","baseClass":"SubstationFunctionalCustom.GroundFunctionalAspect","properties":[{"name":"R","type":"PrimitiveProperty","label":"Resistance","typeName":"string"},{"name":"X","type":"PrimitiveProperty","label":"Reactance","typeName":"string"}]},"GroundingGridFunctionalAspect":{"schemaItemType":"EntityClass","label":"Grounding Grid","baseClass":"SubstationFunctionalCustom.GroundFunctionalAspect","properties":[{"name":"R","type":"PrimitiveProperty","label":"Resistance","typeName":"string"},{"name":"X","type":"PrimitiveProperty","label":"Reactance","typeName":"string"}]},"GroundingClampsFunctionalAspect":{"schemaItemType":"EntityClass","label":"Grounding Clamps","baseClass":"SubstationFunctionalCustom.GroundFunctionalAspect"},"GroundingAccessoriesFunctionalAspect":{"schemaItemType":"EntityClass","label":"Grounding Accessories","baseClass":"SubstationFunctionalCustom.GroundFunctionalAspect","properties":[{"name":"Phase","type":"PrimitiveProperty","label":"Phase","typeName":"string"}]},"BushingFunctionalAspect":{"schemaItemType":"EntityClass","label":"Bushing","baseClass":"SubstationFunctionalCustom.OtherAuxiliaryFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"},{"name":"Phase","type":"PrimitiveProperty","label":"Phase","typeName":"string"}]},"LineTunerFunctionalAspect":{"schemaItemType":"EntityClass","label":"Line Tuner","baseClass":"SubstationFunctionalCustom.OtherAuxiliaryFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"}]},"SurgeCounterFunctionalAspect":{"schemaItemType":"EntityClass","label":"Surge Counter","baseClass":"SubstationFunctionalCustom.OtherAuxiliaryFunctionalAspect"},"GuyStrainInsulatorFunctionalAspect":{"schemaItemType":"EntityClass","label":"Guy Strain Insulator","baseClass":"SubstationFunctionalCustom.OtherAuxiliaryFunctionalAspect"},"ArcHornFunctionalAspect":{"schemaItemType":"EntityClass","label":"Arc Horn","baseClass":"SubstationFunctionalCustom.OtherAuxiliaryFunctionalAspect","properties":[{"name":"Phase","type":"PrimitiveProperty","label":"Phase","typeName":"string"}]},"CoronaRingFunctionalAspect":{"schemaItemType":"EntityClass","label":"Corona Ring","baseClass":"SubstationFunctionalCustom.OtherAuxiliaryFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"},{"name":"Phase","type":"PrimitiveProperty","label":"Phase","typeName":"string"}]},"AnnunciatorFunctionalAspect":{"schemaItemType":"EntityClass","label":"Annunciator","baseClass":"SubstationFunctionalCustom.OtherAuxiliaryFunctionalAspect"},"StatusIndicatorFunctionalAspect":{"schemaItemType":"EntityClass","label":"Status Indicator","baseClass":"SubstationFunctionalCustom.OtherAuxiliaryFunctionalAspect"},"OverheadStructureFunctionalAspect":{"schemaItemType":"EntityClass","label":"Overhead Structure","baseClass":"SubstationFunctionalCustom.StructureCustomFunctionalAspect"},"BusStructureFunctionalAspect":{"schemaItemType":"EntityClass","label":"Bus Structure","baseClass":"SubstationFunctionalCustom.OverheadStructureFunctionalAspect"},"EquipmentStructureFunctionalAspect":{"schemaItemType":"EntityClass","label":"Equipment Structure","baseClass":"SubstationFunctionalCustom.OverheadStructureFunctionalAspect"},"DeadEndStructureFunctionalAspect":{"schemaItemType":"EntityClass","label":"Dead-end Structure","baseClass":"SubstationFunctionalCustom.OverheadStructureFunctionalAspect"},"PoleFunctionalAspect":{"schemaItemType":"EntityClass","label":"Pole","description":"Distribution pole used to support the overhead conductors and related equipment","baseClass":"SubstationFunctionalCustom.OverheadStructureFunctionalAspect"},"SupportWireFunctionalAspect":{"schemaItemType":"EntityClass","label":"Support Wire","baseClass":"SubstationFunctionalCustom.OverheadStructureFunctionalAspect"},"CableSupportsFunctionalAspect":{"schemaItemType":"EntityClass","label":"Cable Supports","baseClass":"SubstationFunctionalCustom.StructureCustomFunctionalAspect"},"GuyWireFunctionalAspect":{"schemaItemType":"EntityClass","label":"Guy Wire","baseClass":"SubstationFunctionalCustom.SupportWireFunctionalAspect"},"GuyWireAccessoriesFunctionalAspect":{"schemaItemType":"EntityClass","label":"Guy Wire Accessories","baseClass":"SubstationFunctionalCustom.CableSupportsFunctionalAspect"},"CableSpacerFunctionalAspect":{"schemaItemType":"EntityClass","label":"Cable Spacer","baseClass":"SubstationFunctionalCustom.CableSupportsFunctionalAspect"},"CableFunctionalAspect":{"schemaItemType":"EntityClass","label":"Cable","baseClass":"SubstationFunctionalCustom.StructureCustomFunctionalAspect"},"SpanGuyFunctionalAspect":{"schemaItemType":"EntityClass","label":"Span Guy","baseClass":"SubstationFunctionalCustom.CableFunctionalAspect"},"DownGuyFunctionalAspect":{"schemaItemType":"EntityClass","label":"Down Guy","baseClass":"SubstationFunctionalCustom.CableFunctionalAspect"},"UndergroundStructureFunctionalAspect":{"schemaItemType":"EntityClass","label":"Underground Structure","baseClass":"SubstationFunctionalCustom.StructureCustomFunctionalAspect"},"VaultFunctionalAspect":{"schemaItemType":"EntityClass","label":"Vault","baseClass":"SubstationFunctionalCustom.UndergroundStructureFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"}]},"ManholeFunctionalAspect":{"schemaItemType":"EntityClass","label":"Manhole","baseClass":"SubstationFunctionalCustom.UndergroundStructureFunctionalAspect"},"AnchorCageFunctionalAspect":{"schemaItemType":"EntityClass","label":"Anchor Cage","baseClass":"SubstationFunctionalCustom.UndergroundStructureFunctionalAspect"},"FastenersFunctionalAspect":{"schemaItemType":"EntityClass","label":"Fasteners","baseClass":"SubstationFunctionalCustom.StructureCustomFunctionalAspect"},"SupportsFunctionalAspect":{"schemaItemType":"EntityClass","label":"Supports","baseClass":"SubstationFunctionalCustom.StructureCustomFunctionalAspect"},"BoltFunctionalAspect":{"schemaItemType":"EntityClass","label":"Bolt","baseClass":"SubstationFunctionalCustom.FastenersFunctionalAspect"},"WasherFunctionalAspect":{"schemaItemType":"EntityClass","label":"Washer","baseClass":"SubstationFunctionalCustom.FastenersFunctionalAspect"},"NutsFunctionalAspect":{"schemaItemType":"EntityClass","label":"Nuts","baseClass":"SubstationFunctionalCustom.FastenersFunctionalAspect"},"ScrewFunctionalAspect":{"schemaItemType":"EntityClass","label":"Screw","baseClass":"SubstationFunctionalCustom.FastenersFunctionalAspect"},"LiftingLugsFunctionalAspect":{"schemaItemType":"EntityClass","label":"Lifting Lugs","baseClass":"SubstationFunctionalCustom.FastenersFunctionalAspect"},"BusSupportFunctionalAspect":{"schemaItemType":"EntityClass","label":"Bus Support","baseClass":"SubstationFunctionalCustom.SupportsFunctionalAspect"},"BracketFunctionalAspect":{"schemaItemType":"EntityClass","label":"Bracket","baseClass":"SubstationFunctionalCustom.SupportsFunctionalAspect"},"UboltFunctionalAspect":{"schemaItemType":"EntityClass","label":"U-Bolt","baseClass":"SubstationFunctionalCustom.SupportsFunctionalAspect"},"MountingKitFunctionalAspect":{"schemaItemType":"EntityClass","label":"Mounting Kit","description":"Additional components needed to mount equipment","baseClass":"SubstationFunctionalCustom.SupportsFunctionalAspect"},"PlatformFunctionalAspect":{"schemaItemType":"EntityClass","label":"Platform","baseClass":"SubstationFunctionalCustom.FoundationCustomFunctionalAspect"},"EquipmentFoundationFunctionalAspect":{"schemaItemType":"EntityClass","label":"Equipment Foundation","baseClass":"SubstationFunctionalCustom.FoundationCustomFunctionalAspect"},"StructureFoundationFunctionalAspect":{"schemaItemType":"EntityClass","label":"Structure Foundation","baseClass":"SubstationFunctionalCustom.FoundationCustomFunctionalAspect"},"WalkingPlatformFunctionalAspect":{"schemaItemType":"EntityClass","label":"Walking platform","baseClass":"SubstationFunctionalCustom.PlatformFunctionalAspect"},"SwitchOperatorPlatformFunctionalAspect":{"schemaItemType":"EntityClass","label":"Switch Operator Platform","baseClass":"SubstationFunctionalCustom.PlatformFunctionalAspect"},"ElectricalBuildingFunctionalAspect":{"schemaItemType":"EntityClass","label":"Electrical Building","baseClass":"SubstationFunctionalCustom.SubstationCustomFunctionalAspect"},"LVSwitchFunctionalAspect":{"schemaItemType":"EntityClass","label":"LV Switches","baseClass":"SubstationFunctionalCustom.ElectricalBuildingFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"}]},"AudioVisualDeviceFunctionalAspect":{"schemaItemType":"EntityClass","label":"Audio Visual Device","baseClass":"SubstationFunctionalCustom.ElectricalBuildingFunctionalAspect"},"CommunicationDeviceFunctionalAspect":{"schemaItemType":"EntityClass","label":"Communication Device","baseClass":"SubstationFunctionalCustom.ElectricalBuildingFunctionalAspect"},"ElectricPanelFunctionalAspect":{"schemaItemType":"EntityClass","label":"Electric Panel","baseClass":"SubstationFunctionalCustom.ElectricalBuildingFunctionalAspect"},"LVBatteryFunctionalAspect":{"schemaItemType":"EntityClass","label":"Low Voltage Battery","description":"A device in which electrical energy is stored and from which energy may be progressively released.","baseClass":"SubstationFunctionalCustom.ElectricalBuildingFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"}]},"ConditionerDeviceFunctionalAspect":{"schemaItemType":"EntityClass","label":"Conditioner Device","description":"used to remove unwanted matter from an electric or electronic signal","baseClass":"SubstationFunctionalCustom.ElectricalBuildingFunctionalAspect"},"ElectricLoadTimeControlFunctionalAspect":{"schemaItemType":"EntityClass","label":"Electric Load Time Control","description":"A device that applies control to the provision or flow of electrical energy over time ","baseClass":"SubstationFunctionalCustom.ElectricalBuildingFunctionalAspect"},"PowerOutletFunctionalAspect":{"schemaItemType":"EntityClass","label":"Outlet","baseClass":"SubstationFunctionalCustom.ElectricalBuildingFunctionalAspect"},"FanFunctionalAspect":{"schemaItemType":"EntityClass","label":"Fan","baseClass":"SubstationFunctionalCustom.ElectricalBuildingFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"},{"name":"Phase","type":"PrimitiveProperty","label":"Phase","typeName":"string"}]},"LightingFixtureFunctionalAspect":{"schemaItemType":"EntityClass","label":"Lighting Fixture","baseClass":"SubstationFunctionalCustom.ElectricalBuildingFunctionalAspect"},"PowerBatteryFunctionalAspect":{"schemaItemType":"EntityClass","label":"Power Battery","baseClass":"SubstationFunctionalCustom.ElectricalBuildingFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"},{"name":"Phase","type":"PrimitiveProperty","label":"Phase","typeName":"string"}]},"EnclosureFunctionalAspect":{"schemaItemType":"EntityClass","label":"Enclosure","baseClass":"SubstationFunctionalCustom.ElectricalBuildingFunctionalAspect"},"SolarDeviceFunctionalAspect":{"schemaItemType":"EntityClass","label":"Solar Device","baseClass":"SubstationFunctionalCustom.ElectricalBuildingFunctionalAspect"},"RacewayFunctionalAspect":{"schemaItemType":"EntityClass","label":"Raceway","baseClass":"SubstationFunctionalCustom.SubstationCustomFunctionalAspect"},"CoverFunctionalAspect":{"schemaItemType":"EntityClass","label":"Cover","baseClass":"SubstationFunctionalCustom.EnclosureFunctionalAspect"},"CabinetFunctionalAspect":{"schemaItemType":"EntityClass","label":"Cabinet","baseClass":"SubstationFunctionalCustom.EnclosureFunctionalAspect"},"GasketFunctionalAspect":{"schemaItemType":"EntityClass","label":"Gasket","baseClass":"SubstationFunctionalCustom.EnclosureFunctionalAspect"},"SecondaryCutOutFunctionalAspect":{"schemaItemType":"EntityClass","label":"Secondary Cut Out","baseClass":"SubstationFunctionalCustom.EnclosureFunctionalAspect"},"PanelboardAssemblyFunctionalAspect":{"schemaItemType":"EntityClass","label":"Panel Board Assembly","baseClass":"SubstationFunctionalCustom.EnclosureFunctionalAspect"},"PullBoxFunctionalAspect":{"schemaItemType":"EntityClass","label":"Pull Box","baseClass":"SubstationFunctionalCustom.EnclosureFunctionalAspect"},"JunctionBoxFunctionalAspect":{"schemaItemType":"EntityClass","label":"Junction Box","description":"A point where one or more conducting equipments are connected with zero resistance.","baseClass":"SubstationFunctionalCustom.EnclosureFunctionalAspect","properties":[{"name":"EquipmentDefinitionCode","type":"PrimitiveProperty","label":"Equipment Definition Code","typeName":"string"}]},"OutletBodyFunctionalAspect":{"schemaItemType":"EntityClass","label":"Outlet Body","baseClass":"SubstationFunctionalCustom.EnclosureFunctionalAspect"},"CableTrenchFunctionalAspect":{"schemaItemType":"EntityClass","label":"Cable Trench","baseClass":"SubstationFunctionalCustom.RacewayFunctionalAspect","properties":[{"name":"NumberOfCables","type":"PrimitiveProperty","label":"Number Of Cables","typeName":"string"}]},"DuctbankFunctionalAspect":{"schemaItemType":"EntityClass","label":"Duct bank","baseClass":"SubstationFunctionalCustom.RacewayFunctionalAspect","properties":[{"name":"NumberOfCables","type":"PrimitiveProperty","label":"Number Of Cables","typeName":"string"}]},"CableTrayFunctionalAspect":{"schemaItemType":"EntityClass","label":"Cable Tray","baseClass":"SubstationFunctionalCustom.RacewayFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"},{"name":"PercentFill","type":"PrimitiveProperty","label":"Percent Filled","typeName":"string"},{"name":"NumberOfCables","type":"PrimitiveProperty","label":"Number Of Cables","typeName":"string"}]},"CableLadderFunctionalAspect":{"schemaItemType":"EntityClass","label":"Cable Ladder","baseClass":"SubstationFunctionalCustom.RacewayFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"},{"name":"PercentFill","type":"PrimitiveProperty","label":"Percent Filled","typeName":"string"},{"name":"NumberOfCables","type":"PrimitiveProperty","label":"Number Of Cables","typeName":"string"}]},"CableLadderFittingFunctionalAspect":{"schemaItemType":"EntityClass","label":"Cable Ladder Fitting","baseClass":"SubstationFunctionalCustom.RacewayFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"},{"name":"PercentFill","type":"PrimitiveProperty","label":"Percent Filled","typeName":"string"},{"name":"NumberOfCables","type":"PrimitiveProperty","label":"Number Of Cables","typeName":"string"}]},"CableTrayFittingsFunctionalAspect":{"schemaItemType":"EntityClass","label":"Cable Tray Fittings","baseClass":"SubstationFunctionalCustom.RacewayFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"},{"name":"PercentFill","type":"PrimitiveProperty","label":"Percent Filled","typeName":"string"},{"name":"NumberOfCables","type":"PrimitiveProperty","label":"Number Of Cables","typeName":"string"}]},"CableTrayCoverFunctionalAspect":{"schemaItemType":"EntityClass","label":"Cable Tray Cover","baseClass":"SubstationFunctionalCustom.RacewayFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"},{"name":"PercentFill","type":"PrimitiveProperty","label":"Percent Filled","typeName":"string"}]},"WirewayFunctionalAspect":{"schemaItemType":"EntityClass","label":"Wireway","baseClass":"SubstationFunctionalCustom.RacewayFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"},{"name":"PercentFill","type":"PrimitiveProperty","label":"Percent Filled","typeName":"string"},{"name":"NumberOfCables","type":"PrimitiveProperty","label":"Number Of Cables","typeName":"string"}]},"ConduitFittingFunctionalAspect":{"schemaItemType":"EntityClass","label":"Conduit Fittings","baseClass":"SubstationFunctionalCustom.RacewayFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"},{"name":"PercentFill","type":"PrimitiveProperty","label":"Percent Filled","typeName":"string"},{"name":"NumberOfCables","type":"PrimitiveProperty","label":"Number Of Cables","typeName":"string"}]},"ConduitFunctionalAspect":{"schemaItemType":"EntityClass","label":"Conduit","baseClass":"SubstationFunctionalCustom.RacewayFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"},{"name":"PercentFill","type":"PrimitiveProperty","label":"Percent Filled","typeName":"string"},{"name":"NumberOfCables","type":"PrimitiveProperty","label":"Number Of Cables","typeName":"string"}]},"MiscellaneousFunctionalAspect":{"schemaItemType":"EntityClass","label":"Miscellaneous","baseClass":"SubstationFunctionalCustom.SubstationCustomFunctionalAspect"},"FenceFunctionalAspect":{"schemaItemType":"EntityClass","label":"Fence","baseClass":"SubstationFunctionalCustom.MiscellaneousFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"}]},"GateFunctionalAspect":{"schemaItemType":"EntityClass","label":"Gate","baseClass":"SubstationFunctionalCustom.MiscellaneousFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"}]},"ControlBuildingFunctionalAspect":{"schemaItemType":"EntityClass","label":"Control Building","baseClass":"SubstationFunctionalCustom.MiscellaneousFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"}]},"OilContainmentSystemFunctionalAspect":{"schemaItemType":"EntityClass","label":"Oil Containment System","baseClass":"SubstationFunctionalCustom.MiscellaneousFunctionalAspect","properties":[{"name":"YearOfManufacture","type":"PrimitiveProperty","label":"Year Of Manufacture","typeName":"dateTime"}]},"PhysicalSafetyBarrierFunctionalAspect":{"schemaItemType":"EntityClass","label":"Physical Safety Barrier","baseClass":"SubstationFunctionalCustom.MiscellaneousFunctionalAspect"},"GeneralHardwareFunctionalAspect":{"schemaItemType":"EntityClass","label":"General Hardware","baseClass":"SubstationFunctionalCustom.MiscellaneousFunctionalAspect"},"NameplateFunctionalAspect":{"schemaItemType":"EntityClass","label":"Nameplate","description":"Mounted on the equipment, and contains most relevant equipment attributes. Can be provided by manufacturer or created by utility using the data from design.","baseClass":"SubstationFunctionalCustom.MiscellaneousFunctionalAspect"},"TerrainFunctionalAspect":{"schemaItemType":"EntityClass","label":"Terrain","description":"DTM Terrain","baseClass":"SubstationFunctionalCustom.MiscellaneousFunctionalAspect"},"AnimalGuardFunctionalAspect":{"schemaItemType":"EntityClass","label":"Animal Guard","baseClass":"SubstationFunctionalCustom.PhysicalSafetyBarrierFunctionalAspect"},"FireBarrierFunctionalAspect":{"schemaItemType":"EntityClass","label":"Fire Barrier","baseClass":"SubstationFunctionalCustom.PhysicalSafetyBarrierFunctionalAspect"},"VehicleBarrierFunctionalAspect":{"schemaItemType":"EntityClass","label":"Vehicle Barrier","baseClass":"SubstationFunctionalCustom.PhysicalSafetyBarrierFunctionalAspect"}}}
|
|
@@ -0,0 +1,732 @@
|
|
|
1
|
+
<?xml version="1.0" encoding="UTF-8"?>
|
|
2
|
+
<!-- ==================================================================================
|
|
3
|
+
| * Copyright (c) Bentley Systems, Incorporated. All rights reserved.
|
|
4
|
+
| * See LICENSE.md in the project root for license terms and full copyright notice.
|
|
5
|
+
======================================================================================= -->
|
|
6
|
+
<ECSchema xmlns="http://www.bentley.com/schemas/Bentley.ECXML.3.2" schemaName="SubstationFunctionalCustom" version="01.00.05" alias="subfuncc" displayLabel="SubstationFunctionalCustom" description="This schema contains classes used for Substation Design.">
|
|
7
|
+
<ECSchemaReference name="BisCore" version="01.00.25" alias="bis"/>
|
|
8
|
+
<ECSchemaReference name="PowerSystemResourcesFunctional" version="01.00.01" alias="psrf" />
|
|
9
|
+
<ECSchemaReference name="SubstationFunctional" version="01.00.05" alias="subfunc" />
|
|
10
|
+
<ECSchemaReference name="CoreCustomAttributes" version="01.00.04" alias="CoreCA" />
|
|
11
|
+
<ECSchemaReference name="BisCustomAttributes" version="01.00.00" alias="bisCA" />
|
|
12
|
+
<ECCustomAttributes>
|
|
13
|
+
<DynamicSchema xmlns="CoreCustomAttributes.01.00.04"/>
|
|
14
|
+
<ProductionStatus xmlns="CoreCustomAttributes.01.00.04">
|
|
15
|
+
<SupportedUse>NotForProduction</SupportedUse>
|
|
16
|
+
</ProductionStatus>
|
|
17
|
+
<SchemaLayerInfo xmlns="BisCustomAttributes.01.00.00">
|
|
18
|
+
<Value>Application</Value>
|
|
19
|
+
</SchemaLayerInfo>
|
|
20
|
+
</ECCustomAttributes>
|
|
21
|
+
<ECEntityClass typeName="EquipmentCustomFunctionalAspect" displayLabel="Equipment Functional Aspect" description="Contains properties of an FunctionalAspect." modifier="None">
|
|
22
|
+
<BaseClass>psrf:EquipmentFunctionalAspect</BaseClass>
|
|
23
|
+
<ECProperty propertyName="IsUsingSharedDeviceId" displayLabel="Is Using Shared Device Id" typeName="boolean" />
|
|
24
|
+
<ECProperty propertyName="DesignWorkOrderNumber" displayLabel="Design Work Order Number" typeName="string" />
|
|
25
|
+
<ECProperty propertyName="Location" displayLabel="Location" typeName="string" />
|
|
26
|
+
<ECProperty propertyName="Installation" displayLabel="Installation" typeName="string" />
|
|
27
|
+
<ECProperty propertyName="BOMDocumentVersion" displayLabel="BOM Document Version" typeName="string" />
|
|
28
|
+
<ECProperty propertyName="DesignRevisionNumber" displayLabel="Design Revision Number" typeName="string" />
|
|
29
|
+
<ECProperty propertyName="SubstationName" displayLabel="Substation Name" typeName="string" />
|
|
30
|
+
<ECProperty propertyName="SubstationIdentifier" displayLabel="Substation Identifier" typeName="string" />
|
|
31
|
+
</ECEntityClass>
|
|
32
|
+
<ECEntityClass typeName="StructureCustomFunctionalAspect" displayLabel="Structure Functional Aspect" description="Contains properties of an FunctionalAspect." modifier="None">
|
|
33
|
+
<BaseClass>psrf:StructureFunctionalAspect</BaseClass>
|
|
34
|
+
<ECProperty propertyName="IsUsingSharedDeviceId" displayLabel="Is Using Shared Device Id" typeName="boolean" />
|
|
35
|
+
<ECProperty propertyName="DesignWorkOrderNumber" displayLabel="Design Work Order Number" typeName="string" />
|
|
36
|
+
<ECProperty propertyName="Location" displayLabel="Location" typeName="string" />
|
|
37
|
+
<ECProperty propertyName="Installation" displayLabel="Installation" typeName="string" />
|
|
38
|
+
<ECProperty propertyName="BOMDocumentVersion" displayLabel="BOM Document Version" typeName="string" />
|
|
39
|
+
<ECProperty propertyName="DesignRevisionNumber" displayLabel="Design Revision Number" typeName="string" />
|
|
40
|
+
<ECProperty propertyName="SubstationName" displayLabel="Substation Name" typeName="string" />
|
|
41
|
+
<ECProperty propertyName="SubstationIdentifier" displayLabel="Substation Identifier" typeName="string" />
|
|
42
|
+
</ECEntityClass>
|
|
43
|
+
<ECEntityClass typeName="FoundationCustomFunctionalAspect" displayLabel="Foundation Functional Aspect" description="Contains properties of an FunctionalAspect." modifier="None">
|
|
44
|
+
<BaseClass>psrf:FoundationFunctionalAspect</BaseClass>
|
|
45
|
+
<ECProperty propertyName="IsUsingSharedDeviceId" displayLabel="Is Using Shared Device Id" typeName="boolean" />
|
|
46
|
+
<ECProperty propertyName="DesignWorkOrderNumber" displayLabel="Design Work Order Number" typeName="string" />
|
|
47
|
+
<ECProperty propertyName="Location" displayLabel="Location" typeName="string" />
|
|
48
|
+
<ECProperty propertyName="Installation" displayLabel="Installation" typeName="string" />
|
|
49
|
+
<ECProperty propertyName="BOMDocumentVersion" displayLabel="BOM Document Version" typeName="string" />
|
|
50
|
+
<ECProperty propertyName="DesignRevisionNumber" displayLabel="Design Revision Number" typeName="string" />
|
|
51
|
+
<ECProperty propertyName="SubstationName" displayLabel="Substation Name" typeName="string" />
|
|
52
|
+
<ECProperty propertyName="SubstationIdentifier" displayLabel="Substation Identifier" typeName="string" />
|
|
53
|
+
</ECEntityClass>
|
|
54
|
+
<ECEntityClass typeName="SubstationCustomFunctionalAspect" displayLabel="Substation Functional Aspect" description="Contains properties of an FunctionalAspect." modifier="None">
|
|
55
|
+
<BaseClass>subfunc:SubstationFunctionalAspect</BaseClass>
|
|
56
|
+
<ECProperty propertyName="IsUsingSharedDeviceId" displayLabel="Is Using Shared Device Id" typeName="boolean" />
|
|
57
|
+
<ECProperty propertyName="DesignWorkOrderNumber" displayLabel="Design Work Order Number" typeName="string" />
|
|
58
|
+
<ECProperty propertyName="Location" displayLabel="Location" typeName="string" />
|
|
59
|
+
<ECProperty propertyName="Installation" displayLabel="Installation" typeName="string" />
|
|
60
|
+
<ECProperty propertyName="BOMDocumentVersion" displayLabel="BOM Document Version" typeName="string" />
|
|
61
|
+
<ECProperty propertyName="DesignRevisionNumber" displayLabel="Design Revision Number" typeName="string" />
|
|
62
|
+
<ECProperty propertyName="SubstationName" displayLabel="Substation Name" typeName="string" />
|
|
63
|
+
<ECProperty propertyName="SubstationIdentifier" displayLabel="Substation Identifier" typeName="string" />
|
|
64
|
+
</ECEntityClass>
|
|
65
|
+
<ECRelationshipClass typeName="EquipmentFunctionalOwnsEquipmentCustomFunctionalAspect" strength="embedding" modifier="None">
|
|
66
|
+
<BaseClass>bis:ElementOwnsUniqueAspect</BaseClass>
|
|
67
|
+
<!-- @see ElementUniqueAspect.Element ECNavigationProperty -->
|
|
68
|
+
<Source multiplicity="(1..1)" roleLabel="owns" polymorphic="true">
|
|
69
|
+
<Class class="psrf:EquipmentFunctional"/>
|
|
70
|
+
</Source>
|
|
71
|
+
<Target multiplicity="(0..*)" roleLabel="is owned by" polymorphic="true">
|
|
72
|
+
<!-- Note: multiplicity=(0..*) is correct. While an Element can only have 1 unique aspect per aspect class, it can have N unique aspects total. -->
|
|
73
|
+
<Class class="EquipmentCustomFunctionalAspect"/>
|
|
74
|
+
</Target>
|
|
75
|
+
</ECRelationshipClass>
|
|
76
|
+
<ECRelationshipClass typeName="StructureFunctionalOwnsStructureCustomFunctionalAspect" strength="embedding" modifier="None">
|
|
77
|
+
<BaseClass>bis:ElementOwnsUniqueAspect</BaseClass>
|
|
78
|
+
<!-- @see ElementUniqueAspect.Element ECNavigationProperty -->
|
|
79
|
+
<Source multiplicity="(1..1)" roleLabel="owns" polymorphic="true">
|
|
80
|
+
<Class class="psrf:StructureFunctional"/>
|
|
81
|
+
</Source>
|
|
82
|
+
<Target multiplicity="(0..*)" roleLabel="is owned by" polymorphic="true">
|
|
83
|
+
<!-- Note: multiplicity=(0..*) is correct. While an Element can only have 1 unique aspect per aspect class, it can have N unique aspects total. -->
|
|
84
|
+
<Class class="StructureCustomFunctionalAspect"/>
|
|
85
|
+
</Target>
|
|
86
|
+
</ECRelationshipClass>
|
|
87
|
+
<ECRelationshipClass typeName="FoundationFunctionalOwnsFoundationCustomFunctionalAspect" strength="embedding" modifier="None">
|
|
88
|
+
<BaseClass>bis:ElementOwnsUniqueAspect</BaseClass>
|
|
89
|
+
<!-- @see ElementUniqueAspect.Element ECNavigationProperty -->
|
|
90
|
+
<Source multiplicity="(1..1)" roleLabel="owns" polymorphic="true">
|
|
91
|
+
<Class class="psrf:FoundationFunctional"/>
|
|
92
|
+
</Source>
|
|
93
|
+
<Target multiplicity="(0..*)" roleLabel="is owned by" polymorphic="true">
|
|
94
|
+
<!-- Note: multiplicity=(0..*) is correct. While an Element can only have 1 unique aspect per aspect class, it can have N unique aspects total. -->
|
|
95
|
+
<Class class="FoundationCustomFunctionalAspect"/>
|
|
96
|
+
</Target>
|
|
97
|
+
</ECRelationshipClass>
|
|
98
|
+
<ECRelationshipClass typeName="SubstationFunctionalOwnsSubstationCustomFunctionalAspect" strength="embedding" modifier="None">
|
|
99
|
+
<BaseClass>bis:ElementOwnsUniqueAspect</BaseClass>
|
|
100
|
+
<!-- @see ElementUniqueAspect.Element ECNavigationProperty -->
|
|
101
|
+
<Source multiplicity="(1..1)" roleLabel="owns" polymorphic="true">
|
|
102
|
+
<Class class="subfunc:SubstationFunctional"/>
|
|
103
|
+
</Source>
|
|
104
|
+
<Target multiplicity="(0..*)" roleLabel="is owned by" polymorphic="true">
|
|
105
|
+
<!-- Note: multiplicity=(0..*) is correct. While an Element can only have 1 unique aspect per aspect class, it can have N unique aspects total. -->
|
|
106
|
+
<Class class="SubstationCustomFunctionalAspect"/>
|
|
107
|
+
</Target>
|
|
108
|
+
</ECRelationshipClass>
|
|
109
|
+
<ECEntityClass typeName="SwitchFunctionalAspect" displayLabel="Switch" description="A generic device designed to close, or open, or both, one or more electric circuits. All switches are two terminal devices including grounding switches. The ACDCTerminal.connected at the two sides of the switch shall not be considered for assessing switch connectivity, i.e. only Switch.open, .normalOpen and .locked are relevant." modifier="None">
|
|
110
|
+
<BaseClass>EquipmentCustomFunctionalAspect</BaseClass>
|
|
111
|
+
<ECProperty propertyName="Phase" displayLabel="Phase" typeName="string" />
|
|
112
|
+
</ECEntityClass>
|
|
113
|
+
<ECEntityClass typeName="SectionalizerFunctionalAspect" displayLabel="Sectionalizer" description="Automatic switch that will lock open to isolate a faulted section. It may, or may not, have load breaking capability. Its primary purpose is to provide fault sectionalising at locations where the fault current is either too high, or too low, for proper coordination of fuses." modifier="None">
|
|
114
|
+
<BaseClass>SwitchFunctionalAspect</BaseClass>
|
|
115
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
116
|
+
</ECEntityClass>
|
|
117
|
+
<ECEntityClass typeName="CutFunctionalAspect" displayLabel="Cut" description="A cut separates a line segment into two parts. The cut appears as a switch inserted between these two parts and connects them together. As the cut is normally open there is no galvanic connection between the two line segment parts. But it is possible to close the cut to get galvanic connection.
 The cut terminals are oriented towards the line segment terminals with the same sequence number. Hence the cut terminal with sequence number equal to 1 is oriented to the line segment's terminal with sequence number equal to 1.
 The cut terminals also act as connection points for jumpers and other equipment, e.g. a mobile generator. To enable this, connectivity nodes are placed at the cut terminals. Once the connectivity nodes are in place any conducting equipment can be connected at them." modifier="None">
|
|
118
|
+
<BaseClass>SwitchFunctionalAspect</BaseClass>
|
|
119
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
120
|
+
</ECEntityClass>
|
|
121
|
+
<ECEntityClass typeName="JumperFunctionalAspect" displayLabel="Jumper" description="A short section of conductor with negligible impedance which can be manually removed and replaced if the circuit is de-energized. Note that zero-impedance branches can potentially be modelled by other equipment types." modifier="None">
|
|
122
|
+
<BaseClass>SwitchFunctionalAspect</BaseClass>
|
|
123
|
+
</ECEntityClass>
|
|
124
|
+
<ECEntityClass typeName="FuseFunctionalAspect" displayLabel="Fuse" description="An overcurrent protective device with a circuit opening fusible part that is heated and severed by the passage of overcurrent through it. A fuse is considered a switching device because it breaks current." modifier="None">
|
|
125
|
+
<BaseClass>SwitchFunctionalAspect</BaseClass>
|
|
126
|
+
</ECEntityClass>
|
|
127
|
+
<ECEntityClass typeName="GroundDisconnectorFunctionalAspect" displayLabel="Ground Disconnector" description="A manually operated or motor operated mechanical switching device used for isolating a circuit or equipment from ground.
 Also known as earthing switch" modifier="None">
|
|
128
|
+
<BaseClass>SwitchFunctionalAspect</BaseClass>
|
|
129
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
130
|
+
</ECEntityClass>
|
|
131
|
+
<ECEntityClass typeName="DisconnectorFunctionalAspect" displayLabel="Disconnector" description="A manually operated or motor operated mechanical switching device used for changing the connections in a circuit, or for isolating a circuit or equipment from a source of power. It is required to open or close circuits when negligible current is broken or made." modifier="None">
|
|
132
|
+
<BaseClass>SwitchFunctionalAspect</BaseClass>
|
|
133
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
134
|
+
</ECEntityClass>
|
|
135
|
+
<ECEntityClass typeName="ProtectedSwitchFunctionalAspect" displayLabel="Protected Switch" description="A ProtectedSwitch is a switching device that can be operated by ProtectionEquipment.
 " modifier="None">
|
|
136
|
+
<BaseClass>SwitchFunctionalAspect</BaseClass>
|
|
137
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
138
|
+
</ECEntityClass>
|
|
139
|
+
<ECEntityClass typeName="AuxiliaryEquipmentFunctionalAspect" displayLabel="Auxiliary Equipment" description="AuxiliaryEquipment describe equipment that is not performing any primary functions but support for the equipment performing the primary function.
 AuxiliaryEquipment is attached to primary equipment via an association with Terminal." modifier="None">
|
|
140
|
+
<BaseClass>EquipmentCustomFunctionalAspect</BaseClass>
|
|
141
|
+
</ECEntityClass>
|
|
142
|
+
<ECEntityClass typeName="BreakerFunctionalAspect" displayLabel="Breaker" modifier="None">
|
|
143
|
+
<BaseClass>ProtectedSwitchFunctionalAspect</BaseClass>
|
|
144
|
+
</ECEntityClass>
|
|
145
|
+
<ECEntityClass typeName="RecloserFunctionalAspect" displayLabel="Recloser" description="Pole-mounted fault interrupter with built-in phase and ground relays, current transformer (CT), and supplemental controls." modifier="None">
|
|
146
|
+
<BaseClass>ProtectedSwitchFunctionalAspect</BaseClass>
|
|
147
|
+
</ECEntityClass>
|
|
148
|
+
<ECEntityClass typeName="LoadBreakSwitchFunctionalAspect" displayLabel="Load Break Switch" description="A mechanical switching device capable of making, carrying, and breaking currents under normal operating conditions." modifier="None">
|
|
149
|
+
<BaseClass>ProtectedSwitchFunctionalAspect</BaseClass>
|
|
150
|
+
</ECEntityClass>
|
|
151
|
+
<ECEntityClass typeName="SurgeArresterFunctionalAspect" displayLabel="Surge Arrester" description="Shunt device, installed on the network, usually in the proximity of electrical equipment in order to protect the said equipment against transient voltage transients caused by lightning or switching activity." modifier="None">
|
|
152
|
+
<BaseClass>AuxiliaryEquipmentFunctionalAspect</BaseClass>
|
|
153
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
154
|
+
</ECEntityClass>
|
|
155
|
+
<ECEntityClass typeName="FaultIndicatorFunctionalAspect" displayLabel="Fault Indicator" description="A FaultIndicator is typically only an indicator (which may or may not be remotely monitored), and not a piece of equipment that actually initiates a protection event. It is used for FLISR (Fault Location, Isolation and Restoration) purposes, assisting with the dispatch of crews to "most likely" part of the network (i.e. assists with determining circuit section where the fault most likely happened)." modifier="None">
|
|
156
|
+
<BaseClass>AuxiliaryEquipmentFunctionalAspect</BaseClass>
|
|
157
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
158
|
+
</ECEntityClass>
|
|
159
|
+
<ECEntityClass typeName="WaveTrapFunctionalAspect" displayLabel="Wave Trap" description="Line traps are devices that impede high frequency power line carrier signals yet present a negligible impedance at the main power frequency." modifier="None">
|
|
160
|
+
<BaseClass>AuxiliaryEquipmentFunctionalAspect</BaseClass>
|
|
161
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
162
|
+
</ECEntityClass>
|
|
163
|
+
<ECEntityClass typeName="InsulatorFunctionalAspect" displayLabel="Insulator" modifier="None">
|
|
164
|
+
<BaseClass>AuxiliaryEquipmentFunctionalAspect</BaseClass>
|
|
165
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
166
|
+
<ECProperty propertyName="Phase" displayLabel="Phase" typeName="string" />
|
|
167
|
+
</ECEntityClass>
|
|
168
|
+
<ECEntityClass typeName="SensorFunctionalAspect" displayLabel="Sensor" description="AuxiliaryEquipment describes equipment that does not perform primary functions but supports equipment that does." modifier="None">
|
|
169
|
+
<BaseClass>AuxiliaryEquipmentFunctionalAspect</BaseClass>
|
|
170
|
+
</ECEntityClass>
|
|
171
|
+
<ECEntityClass typeName="EarthFaultCompensatorFunctionalAspect" displayLabel="Earth Fault Compensator" description="A conducting equipment used to represent a connection to ground which is typically used to compensate earth faults. An earth fault compensator device modelled with a single terminal implies a second terminal solidly connected to ground. If two terminals are modelled, the ground is not assumed and normal connection rules apply.
 " modifier="None">
|
|
172
|
+
<BaseClass>EquipmentCustomFunctionalAspect</BaseClass>
|
|
173
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
174
|
+
</ECEntityClass>
|
|
175
|
+
<ECEntityClass typeName="DisconnectingCircuitBreakerFunctionalAspect" displayLabel="Circuit Breaker With Disconnector" description="A circuit breaking device including disconnecting function, eliminating the need for separate disconnectors." modifier="None">
|
|
176
|
+
<BaseClass>BreakerFunctionalAspect</BaseClass>
|
|
177
|
+
</ECEntityClass>
|
|
178
|
+
<ECEntityClass typeName="PotentialTransformerFunctionalAspect" displayLabel="Potential Transformer" description="AuxiliaryEquipment describe equipment that is not performing any primary functions but support for the equipment performing the primary function.
 AuxiliaryEquipment is attached to primary equipment via an association with Terminal." modifier="None">
|
|
179
|
+
<BaseClass>SensorFunctionalAspect</BaseClass>
|
|
180
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
181
|
+
<ECProperty propertyName="Phase" displayLabel="Phase" typeName="string" />
|
|
182
|
+
<ECProperty propertyName="PTRatioUsed" displayLabel="PT Ratio Used" typeName="string" />
|
|
183
|
+
</ECEntityClass>
|
|
184
|
+
<ECEntityClass typeName="CurrentTransformerFunctionalAspect" displayLabel="Current Transformer" modifier="None">
|
|
185
|
+
<BaseClass>SensorFunctionalAspect</BaseClass>
|
|
186
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
187
|
+
<ECProperty propertyName="Phase" displayLabel="Phase" typeName="string" />
|
|
188
|
+
<ECProperty propertyName="CTRatioUsed" displayLabel="CT Ratio Used" typeName="string" />
|
|
189
|
+
</ECEntityClass>
|
|
190
|
+
<ECEntityClass typeName="PostLineSensorFunctionalAspect" displayLabel="Post Line Sensor" description="A sensor used mainly in overhead distribution networks as the source of both current and voltage measurements" modifier="None">
|
|
191
|
+
<BaseClass>SensorFunctionalAspect</BaseClass>
|
|
192
|
+
</ECEntityClass>
|
|
193
|
+
<ECEntityClass typeName="GroundingImpedanceFunctionalAspect" displayLabel="Grounding Impedance" description="A fixed impedance device used for grounding.
 " modifier="None">
|
|
194
|
+
<BaseClass>EarthFaultCompensatorFunctionalAspect</BaseClass>
|
|
195
|
+
<ECProperty propertyName="Phase" displayLabel="Phase" typeName="string" />
|
|
196
|
+
<ECProperty propertyName="R" displayLabel="Resistance" typeName="string" />
|
|
197
|
+
<ECProperty propertyName="X" displayLabel="Reactance" typeName="string" />
|
|
198
|
+
</ECEntityClass>
|
|
199
|
+
<ECEntityClass typeName="PetersenCoilFunctionalAspect" displayLabel="Petersen Coil" description="A variable impedance device normally used to offset line charging during single line faults in an ungrounded section of network." modifier="None">
|
|
200
|
+
<BaseClass>EarthFaultCompensatorFunctionalAspect</BaseClass>
|
|
201
|
+
</ECEntityClass>
|
|
202
|
+
<ECEntityClass typeName="TransformerFunctionalAspect" displayLabel="Transformer" description="Power transformers are utilized in transmission networks with significantly higher voltage, while distribution transformers function in distribution networks defined by lower voltages" modifier="None">
|
|
203
|
+
<BaseClass>EquipmentCustomFunctionalAspect</BaseClass>
|
|
204
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
205
|
+
</ECEntityClass>
|
|
206
|
+
<ECEntityClass typeName="PowerTransformerFunctionalAspect" displayLabel="Power Transformer" modifier="None">
|
|
207
|
+
<BaseClass>TransformerFunctionalAspect</BaseClass>
|
|
208
|
+
</ECEntityClass>
|
|
209
|
+
<ECEntityClass typeName="CompensatorFunctionalAspect" displayLabel="Compensator" description="A Series Compensator is a series capacitor or reactor or an AC transmission line without charging susceptance. It is a two terminal device." modifier="None">
|
|
210
|
+
<BaseClass>EquipmentCustomFunctionalAspect</BaseClass>
|
|
211
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
212
|
+
<ECProperty propertyName="R" displayLabel="Resistance" typeName="string" />
|
|
213
|
+
<ECProperty propertyName="X" displayLabel="Reactance" typeName="string" />
|
|
214
|
+
</ECEntityClass>
|
|
215
|
+
<ECEntityClass typeName="SeriesCompensatorFunctionalAspect" displayLabel="Series Compensator" description="A Series Compensator is a series capacitor or reactor or an AC transmission line without charging susceptance. It is a two terminal device." modifier="None">
|
|
216
|
+
<BaseClass>CompensatorFunctionalAspect</BaseClass>
|
|
217
|
+
</ECEntityClass>
|
|
218
|
+
<ECEntityClass typeName="ConductorFunctionalAspect" displayLabel="Conductor" modifier="None">
|
|
219
|
+
<BaseClass>EquipmentCustomFunctionalAspect</BaseClass>
|
|
220
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
221
|
+
<ECProperty propertyName="Phase" displayLabel="Phase" typeName="string" />
|
|
222
|
+
<ECProperty propertyName="R" displayLabel="Resistance" typeName="string" />
|
|
223
|
+
<ECProperty propertyName="X" displayLabel="Reactance" typeName="string" />
|
|
224
|
+
</ECEntityClass>
|
|
225
|
+
<ECEntityClass typeName="ClampFunctionalAspect" displayLabel="Clamp" modifier="None">
|
|
226
|
+
<BaseClass>EquipmentCustomFunctionalAspect</BaseClass>
|
|
227
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
228
|
+
<ECProperty propertyName="Phase" displayLabel="Phase" typeName="string" />
|
|
229
|
+
</ECEntityClass>
|
|
230
|
+
<ECEntityClass typeName="ConnectorFunctionalAspect" displayLabel="Connector" description="A conductor, or group of conductors, with negligible impedance, that serve to connect other conducting equipment within a single substation and are modelled with a single logical terminal." modifier="None">
|
|
231
|
+
<BaseClass>EquipmentCustomFunctionalAspect</BaseClass>
|
|
232
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
233
|
+
<ECProperty propertyName="Phase" displayLabel="Phase" typeName="string" />
|
|
234
|
+
</ECEntityClass>
|
|
235
|
+
<ECEntityClass typeName="BusbarSectionFunctionalAspect" displayLabel="Busbar Section" description="A conductor, or group of conductors, with negligible impedance, that serve to connect other conducting equipment within a single substation. 
 Voltage measurements are typically obtained from voltage transformers that are connected to busbar sections. A bus bar section may have many physical terminals but for analysis is modelled with exactly one logical terminal." modifier="None">
|
|
236
|
+
<BaseClass>ConnectorFunctionalAspect</BaseClass>
|
|
237
|
+
</ECEntityClass>
|
|
238
|
+
<ECEntityClass typeName="JunctionFunctionalAspect" displayLabel="Junction" description="A point where one or more conducting equipments are connected with zero resistance.
 " modifier="None">
|
|
239
|
+
<BaseClass>ConnectorFunctionalAspect</BaseClass>
|
|
240
|
+
</ECEntityClass>
|
|
241
|
+
<ECEntityClass typeName="EnergyConnectionFunctionalAspect" displayLabel="Energy Connection" modifier="None">
|
|
242
|
+
<BaseClass>EquipmentCustomFunctionalAspect</BaseClass>
|
|
243
|
+
</ECEntityClass>
|
|
244
|
+
<ECEntityClass typeName="EnergySourceFunctionalAspect" displayLabel="Energy Source" modifier="None">
|
|
245
|
+
<BaseClass>EnergyConnectionFunctionalAspect</BaseClass>
|
|
246
|
+
</ECEntityClass>
|
|
247
|
+
<ECEntityClass typeName="EnergyConsumerFunctionalAspect" displayLabel="Energy Consumer" modifier="None">
|
|
248
|
+
<BaseClass>EnergyConnectionFunctionalAspect</BaseClass>
|
|
249
|
+
</ECEntityClass>
|
|
250
|
+
<ECEntityClass typeName="RegulatingConductingEqFunctionalAspect" displayLabel="Regulating Conducting Equipment" modifier="None">
|
|
251
|
+
<BaseClass>EnergyConnectionFunctionalAspect</BaseClass>
|
|
252
|
+
</ECEntityClass>
|
|
253
|
+
<ECEntityClass typeName="GroundFunctionalAspect" displayLabel="Grounding Equipment" modifier="None">
|
|
254
|
+
<BaseClass>EquipmentCustomFunctionalAspect</BaseClass>
|
|
255
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
256
|
+
</ECEntityClass>
|
|
257
|
+
<ECEntityClass typeName="FrequencyConverterFunctionalAspect" displayLabel="Frequency Converter" description="A device to convert from one frequency to another (e.g., frequency F1 to F2) comprises a pair of FrequencyConverter instances. One converts from F1 to DC, the other converts the DC to F2." modifier="None">
|
|
258
|
+
<BaseClass>RegulatingConductingEqFunctionalAspect</BaseClass>
|
|
259
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
260
|
+
</ECEntityClass>
|
|
261
|
+
<ECEntityClass typeName="StaticVarCompensatorFunctionalAspect" displayLabel="Static Var Compensator" description="A facility for providing variable and controllable shunt reactive power. The SVC typically consists of a stepdown transformer, filter, thyristor-controlled reactor, and thyristor-switched capacitor arms.
 
 The SVC may operate in fixed MVar output mode or in voltage control mode. When in voltage control mode, the output of the SVC will be proportional to the deviation of voltage at the controlled bus from the voltage setpoint. The SVC characteristic slope defines the proportion. If the voltage at the controlled bus is equal to the voltage setpoint, the SVC MVar output is zero." modifier="None">
|
|
262
|
+
<BaseClass>RegulatingConductingEqFunctionalAspect</BaseClass>
|
|
263
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
264
|
+
<ECProperty propertyName="R" displayLabel="Resistance" typeName="string" />
|
|
265
|
+
<ECProperty propertyName="X" displayLabel="Reactance" typeName="string" />
|
|
266
|
+
</ECEntityClass>
|
|
267
|
+
<ECEntityClass typeName="ExternalNetworkInjectionFunctionalAspect" displayLabel="External Network Injection" modifier="None">
|
|
268
|
+
<BaseClass>RegulatingConductingEqFunctionalAspect</BaseClass>
|
|
269
|
+
</ECEntityClass>
|
|
270
|
+
<ECEntityClass typeName="ShuntCompensatorFunctionalAspect" displayLabel="Shunt Compensator" modifier="None">
|
|
271
|
+
<BaseClass>RegulatingConductingEqFunctionalAspect</BaseClass>
|
|
272
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
273
|
+
<ECProperty propertyName="Phase" displayLabel="Phase" typeName="string" />
|
|
274
|
+
<ECProperty propertyName="R" displayLabel="Resistance" typeName="string" />
|
|
275
|
+
<ECProperty propertyName="X" displayLabel="Reactance" typeName="string" />
|
|
276
|
+
</ECEntityClass>
|
|
277
|
+
<ECEntityClass typeName="PowerElectronicsConnectionFunctionalAspect" displayLabel="Power Electronic Connection" modifier="None">
|
|
278
|
+
<BaseClass>RegulatingConductingEqFunctionalAspect</BaseClass>
|
|
279
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
280
|
+
<ECProperty propertyName="Phase" displayLabel="Phase" typeName="string" />
|
|
281
|
+
</ECEntityClass>
|
|
282
|
+
<ECEntityClass typeName="RotatingMachineFunctionalAspect" displayLabel="Rotating Machine" modifier="None">
|
|
283
|
+
<BaseClass>RegulatingConductingEqFunctionalAspect</BaseClass>
|
|
284
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
285
|
+
</ECEntityClass>
|
|
286
|
+
<ECEntityClass typeName="DERFunctionalAspect" displayLabel="DER" modifier="None">
|
|
287
|
+
<BaseClass>EquipmentCustomFunctionalAspect</BaseClass>
|
|
288
|
+
</ECEntityClass>
|
|
289
|
+
<ECEntityClass typeName="AsynchronousMachineFunctionalAspect" displayLabel="Asynchronous Machine" modifier="None">
|
|
290
|
+
<BaseClass>RotatingMachineFunctionalAspect</BaseClass>
|
|
291
|
+
</ECEntityClass>
|
|
292
|
+
<ECEntityClass typeName="SynchronousMachineFunctionalAspect" displayLabel="Synchronous Machine" modifier="None">
|
|
293
|
+
<BaseClass>RotatingMachineFunctionalAspect</BaseClass>
|
|
294
|
+
</ECEntityClass>
|
|
295
|
+
<ECEntityClass typeName="BatteryFunctionalAspect" displayLabel="Battery" modifier="None">
|
|
296
|
+
<BaseClass>DERFunctionalAspect</BaseClass>
|
|
297
|
+
</ECEntityClass>
|
|
298
|
+
<ECEntityClass typeName="SolarPanelFunctionalAspect" displayLabel="Solar Panel" modifier="None">
|
|
299
|
+
<BaseClass>DERFunctionalAspect</BaseClass>
|
|
300
|
+
</ECEntityClass>
|
|
301
|
+
<ECEntityClass typeName="WindTurbineFunctionalAspect" displayLabel="Wind Turbine" modifier="None">
|
|
302
|
+
<BaseClass>DERFunctionalAspect</BaseClass>
|
|
303
|
+
</ECEntityClass>
|
|
304
|
+
<ECEntityClass typeName="LightningProtectionFunctionalAspect" displayLabel="Lightning Protection" modifier="None">
|
|
305
|
+
<BaseClass>EquipmentCustomFunctionalAspect</BaseClass>
|
|
306
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
307
|
+
<ECProperty propertyName="R" displayLabel="Resistance" typeName="string" />
|
|
308
|
+
<ECProperty propertyName="X" displayLabel="Reactance" typeName="string" />
|
|
309
|
+
</ECEntityClass>
|
|
310
|
+
<ECEntityClass typeName="LightningMastsFunctionalAspect" displayLabel="Lightning Masts" modifier="None">
|
|
311
|
+
<BaseClass>LightningProtectionFunctionalAspect</BaseClass>
|
|
312
|
+
</ECEntityClass>
|
|
313
|
+
<ECEntityClass typeName="ShieldWireFunctionalAspect" displayLabel="Shield Wire" modifier="None">
|
|
314
|
+
<BaseClass>LightningProtectionFunctionalAspect</BaseClass>
|
|
315
|
+
</ECEntityClass>
|
|
316
|
+
<ECEntityClass typeName="OtherAuxiliaryFunctionalAspect" displayLabel="Other Auxiliary" modifier="None">
|
|
317
|
+
<BaseClass>AuxiliaryEquipmentFunctionalAspect</BaseClass>
|
|
318
|
+
</ECEntityClass>
|
|
319
|
+
<ECEntityClass typeName="EMVTFunctionalAspect" displayLabel="Electromagnetic Voltage Transformers" description="Electromagnetic Voltage Transformers 
 " modifier="None">
|
|
320
|
+
<BaseClass>PotentialTransformerFunctionalAspect</BaseClass>
|
|
321
|
+
</ECEntityClass>
|
|
322
|
+
<ECEntityClass typeName="OVTFunctionalAspect" displayLabel="Optical Voltage Transformers" description="Optical Voltage Transformers 
 " modifier="None">
|
|
323
|
+
<BaseClass>PotentialTransformerFunctionalAspect</BaseClass>
|
|
324
|
+
</ECEntityClass>
|
|
325
|
+
<ECEntityClass typeName="CCVTFunctionalAspect" displayLabel="Capacitive Coupled Voltage Transformer" modifier="None">
|
|
326
|
+
<BaseClass>PotentialTransformerFunctionalAspect</BaseClass>
|
|
327
|
+
</ECEntityClass>
|
|
328
|
+
<ECEntityClass typeName="CombinedCTVTFunctionalAspect" displayLabel="Combined CT/VT " modifier="None">
|
|
329
|
+
<BaseClass>SensorFunctionalAspect</BaseClass>
|
|
330
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
331
|
+
<ECProperty propertyName="Phase" displayLabel="Phase" typeName="string" />
|
|
332
|
+
<ECProperty propertyName="CTRatioUsed" displayLabel="CT Ratio Used" typeName="string" />
|
|
333
|
+
<ECProperty propertyName="PTRatioUsed" displayLabel="PT Ratio Used" typeName="string" />
|
|
334
|
+
</ECEntityClass>
|
|
335
|
+
<ECEntityClass typeName="NeutralGroundingResistorFunctionalAspect" displayLabel="Neutral Grounding Resistor" modifier="None">
|
|
336
|
+
<BaseClass>GroundingImpedanceFunctionalAspect</BaseClass>
|
|
337
|
+
</ECEntityClass>
|
|
338
|
+
<ECEntityClass typeName="NeutralGroundingReactorFunctionalAspect" displayLabel="Neutral Grounding Reactor" description="The conductor used to connect the non-current-carrying metal parts of equipment, raceways and other enclosures to the system grounded conductor, grounding electrode conductor, or both, at the service equipment or at the source of a separately-derived system" modifier="None">
|
|
339
|
+
<BaseClass>GroundingImpedanceFunctionalAspect</BaseClass>
|
|
340
|
+
</ECEntityClass>
|
|
341
|
+
<ECEntityClass typeName="PowerTransformer2WindingsFunctionalAspect" displayLabel="Power Transformer - 2 Windings" modifier="None">
|
|
342
|
+
<BaseClass>PowerTransformerFunctionalAspect</BaseClass>
|
|
343
|
+
</ECEntityClass>
|
|
344
|
+
<ECEntityClass typeName="PowerTransformer3WindingsFunctionalAspect" displayLabel="Power Transformer - 3 Windings" modifier="None">
|
|
345
|
+
<BaseClass>PowerTransformerFunctionalAspect</BaseClass>
|
|
346
|
+
</ECEntityClass>
|
|
347
|
+
<ECEntityClass typeName="DistributionTransformerFunctionalAspect" displayLabel="Distribution Transformer" modifier="None">
|
|
348
|
+
<BaseClass>PowerTransformerFunctionalAspect</BaseClass>
|
|
349
|
+
</ECEntityClass>
|
|
350
|
+
<ECEntityClass typeName="GroundingTransformerwithResistorFunctionalAspect" displayLabel="Zigzag Grounding Transformer with Resistor" modifier="None">
|
|
351
|
+
<BaseClass>PowerTransformerFunctionalAspect</BaseClass>
|
|
352
|
+
<ECProperty propertyName="R" displayLabel="Resistance" typeName="string" />
|
|
353
|
+
<ECProperty propertyName="X" displayLabel="Reactance" typeName="string" />
|
|
354
|
+
</ECEntityClass>
|
|
355
|
+
<ECEntityClass typeName="SeriesCapacitorFunctionalAspect" displayLabel="Series Capacitor" modifier="None">
|
|
356
|
+
<BaseClass>SeriesCompensatorFunctionalAspect</BaseClass>
|
|
357
|
+
</ECEntityClass>
|
|
358
|
+
<ECEntityClass typeName="SeriesReactorFunctionalAspect" displayLabel="Series Reactor" modifier="None">
|
|
359
|
+
<BaseClass>SeriesCompensatorFunctionalAspect</BaseClass>
|
|
360
|
+
</ECEntityClass>
|
|
361
|
+
<ECEntityClass typeName="TCSCFunctionalAspect" displayLabel="Thyristor-Controlled Series Capacitor" modifier="None">
|
|
362
|
+
<BaseClass>SeriesCompensatorFunctionalAspect</BaseClass>
|
|
363
|
+
</ECEntityClass>
|
|
364
|
+
<ECEntityClass typeName="PowerCableFunctionalAspect" displayLabel="Power Cable" modifier="None">
|
|
365
|
+
<BaseClass>ConductorFunctionalAspect</BaseClass>
|
|
366
|
+
</ECEntityClass>
|
|
367
|
+
<ECEntityClass typeName="InsulatedPowerCableFunctionalAspect" displayLabel="Insulated Power Cable" modifier="None">
|
|
368
|
+
<BaseClass>ConductorFunctionalAspect</BaseClass>
|
|
369
|
+
</ECEntityClass>
|
|
370
|
+
<ECEntityClass typeName="CableClampsFunctionalAspect" displayLabel="Cable Clamps" modifier="None">
|
|
371
|
+
<BaseClass>ClampFunctionalAspect</BaseClass>
|
|
372
|
+
</ECEntityClass>
|
|
373
|
+
<ECEntityClass typeName="BusClampsFunctionalAspect" displayLabel="Bus Clamps" modifier="None">
|
|
374
|
+
<BaseClass>ClampFunctionalAspect</BaseClass>
|
|
375
|
+
</ECEntityClass>
|
|
376
|
+
<ECEntityClass typeName="CableConnectorFunctionalAspect" displayLabel="Cable Connector" modifier="None">
|
|
377
|
+
<BaseClass>JunctionFunctionalAspect</BaseClass>
|
|
378
|
+
</ECEntityClass>
|
|
379
|
+
<ECEntityClass typeName="BusConnectorFunctionalAspect" displayLabel="Bus Connector" modifier="None">
|
|
380
|
+
<BaseClass>JunctionFunctionalAspect</BaseClass>
|
|
381
|
+
</ECEntityClass>
|
|
382
|
+
<ECEntityClass typeName="BusAccessoriesFunctionalAspect" displayLabel="Bus Accessories" modifier="None">
|
|
383
|
+
<BaseClass>ConnectorFunctionalAspect</BaseClass>
|
|
384
|
+
</ECEntityClass>
|
|
385
|
+
<ECEntityClass typeName="CableAccessoriesFunctionalAspect" displayLabel="Cable Accessories" modifier="None">
|
|
386
|
+
<BaseClass>ConnectorFunctionalAspect</BaseClass>
|
|
387
|
+
</ECEntityClass>
|
|
388
|
+
<ECEntityClass typeName="LineHardwareFunctionalAspect" displayLabel="Line Hardware" modifier="None">
|
|
389
|
+
<BaseClass>ConnectorFunctionalAspect</BaseClass>
|
|
390
|
+
</ECEntityClass>
|
|
391
|
+
<ECEntityClass typeName="VoltageRegulatorFunctionalAspect" displayLabel="Voltage Regulator" modifier="None">
|
|
392
|
+
<BaseClass>RegulatingConductingEqFunctionalAspect</BaseClass>
|
|
393
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
394
|
+
<ECProperty propertyName="Phase" displayLabel="Phase" typeName="string" />
|
|
395
|
+
</ECEntityClass>
|
|
396
|
+
<ECEntityClass typeName="ShuntCapacitorFunctionalAspect" displayLabel="Shunt Capacitor" description="Single capacitor unit used to inject reactive power (positive Q) to improve voltage " modifier="None">
|
|
397
|
+
<BaseClass>ShuntCompensatorFunctionalAspect</BaseClass>
|
|
398
|
+
</ECEntityClass>
|
|
399
|
+
<ECEntityClass typeName="ShuntCapacitorBankFunctionalAspect" displayLabel="Shunt Capacitor Bank" description="Group of capacitor units connected in series/parallel; often switchable in steps 
 " modifier="None">
|
|
400
|
+
<BaseClass>ShuntCompensatorFunctionalAspect</BaseClass>
|
|
401
|
+
</ECEntityClass>
|
|
402
|
+
<ECEntityClass typeName="ShuntReactorFunctionalAspect" displayLabel="Shunt Reactor" modifier="None">
|
|
403
|
+
<BaseClass>ShuntCompensatorFunctionalAspect</BaseClass>
|
|
404
|
+
</ECEntityClass>
|
|
405
|
+
<ECEntityClass typeName="ShuntReactorBankFunctionalAspect" displayLabel="Shunt Reactor Bank" modifier="None">
|
|
406
|
+
<BaseClass>ShuntCompensatorFunctionalAspect</BaseClass>
|
|
407
|
+
</ECEntityClass>
|
|
408
|
+
<ECEntityClass typeName="RectifierFunctionalAspect" displayLabel="Rectifier" modifier="None">
|
|
409
|
+
<BaseClass>PowerElectronicsConnectionFunctionalAspect</BaseClass>
|
|
410
|
+
</ECEntityClass>
|
|
411
|
+
<ECEntityClass typeName="InverterFunctionalAspect" displayLabel="Inverter" modifier="None">
|
|
412
|
+
<BaseClass>PowerElectronicsConnectionFunctionalAspect</BaseClass>
|
|
413
|
+
</ECEntityClass>
|
|
414
|
+
<ECEntityClass typeName="GroundingRodFunctionalAspect" displayLabel="Grounding Rod" modifier="None">
|
|
415
|
+
<BaseClass>GroundFunctionalAspect</BaseClass>
|
|
416
|
+
<ECProperty propertyName="R" displayLabel="Resistance" typeName="string" />
|
|
417
|
+
<ECProperty propertyName="X" displayLabel="Reactance" typeName="string" />
|
|
418
|
+
</ECEntityClass>
|
|
419
|
+
<ECEntityClass typeName="GroundingGridFunctionalAspect" displayLabel="Grounding Grid" modifier="None">
|
|
420
|
+
<BaseClass>GroundFunctionalAspect</BaseClass>
|
|
421
|
+
<ECProperty propertyName="R" displayLabel="Resistance" typeName="string" />
|
|
422
|
+
<ECProperty propertyName="X" displayLabel="Reactance" typeName="string" />
|
|
423
|
+
</ECEntityClass>
|
|
424
|
+
<ECEntityClass typeName="GroundingClampsFunctionalAspect" displayLabel="Grounding Clamps" modifier="None">
|
|
425
|
+
<BaseClass>GroundFunctionalAspect</BaseClass>
|
|
426
|
+
</ECEntityClass>
|
|
427
|
+
<ECEntityClass typeName="GroundingAccessoriesFunctionalAspect" displayLabel="Grounding Accessories" modifier="None">
|
|
428
|
+
<BaseClass>GroundFunctionalAspect</BaseClass>
|
|
429
|
+
<ECProperty propertyName="Phase" displayLabel="Phase" typeName="string" />
|
|
430
|
+
</ECEntityClass>
|
|
431
|
+
<ECEntityClass typeName="BushingFunctionalAspect" displayLabel="Bushing" modifier="None">
|
|
432
|
+
<BaseClass>OtherAuxiliaryFunctionalAspect</BaseClass>
|
|
433
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
434
|
+
<ECProperty propertyName="Phase" displayLabel="Phase" typeName="string" />
|
|
435
|
+
</ECEntityClass>
|
|
436
|
+
<ECEntityClass typeName="LineTunerFunctionalAspect" displayLabel="Line Tuner" modifier="None">
|
|
437
|
+
<BaseClass>OtherAuxiliaryFunctionalAspect</BaseClass>
|
|
438
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
439
|
+
</ECEntityClass>
|
|
440
|
+
<ECEntityClass typeName="SurgeCounterFunctionalAspect" displayLabel="Surge Counter" modifier="None">
|
|
441
|
+
<BaseClass>OtherAuxiliaryFunctionalAspect</BaseClass>
|
|
442
|
+
</ECEntityClass>
|
|
443
|
+
<ECEntityClass typeName="GuyStrainInsulatorFunctionalAspect" displayLabel="Guy Strain Insulator" modifier="None">
|
|
444
|
+
<BaseClass>OtherAuxiliaryFunctionalAspect</BaseClass>
|
|
445
|
+
</ECEntityClass>
|
|
446
|
+
<ECEntityClass typeName="ArcHornFunctionalAspect" displayLabel="Arc Horn" modifier="None">
|
|
447
|
+
<BaseClass>OtherAuxiliaryFunctionalAspect</BaseClass>
|
|
448
|
+
<ECProperty propertyName="Phase" displayLabel="Phase" typeName="string" />
|
|
449
|
+
</ECEntityClass>
|
|
450
|
+
<ECEntityClass typeName="CoronaRingFunctionalAspect" displayLabel="Corona Ring" modifier="None">
|
|
451
|
+
<BaseClass>OtherAuxiliaryFunctionalAspect</BaseClass>
|
|
452
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
453
|
+
<ECProperty propertyName="Phase" displayLabel="Phase" typeName="string" />
|
|
454
|
+
</ECEntityClass>
|
|
455
|
+
<ECEntityClass typeName="AnnunciatorFunctionalAspect" displayLabel="Annunciator" modifier="None">
|
|
456
|
+
<BaseClass>OtherAuxiliaryFunctionalAspect</BaseClass>
|
|
457
|
+
</ECEntityClass>
|
|
458
|
+
<ECEntityClass typeName="StatusIndicatorFunctionalAspect" displayLabel="Status Indicator" modifier="None">
|
|
459
|
+
<BaseClass>OtherAuxiliaryFunctionalAspect</BaseClass>
|
|
460
|
+
</ECEntityClass>
|
|
461
|
+
<ECEntityClass typeName="OverheadStructureFunctionalAspect" displayLabel="Overhead Structure" modifier="None">
|
|
462
|
+
<BaseClass>StructureCustomFunctionalAspect</BaseClass>
|
|
463
|
+
</ECEntityClass>
|
|
464
|
+
<ECEntityClass typeName="BusStructureFunctionalAspect" displayLabel="Bus Structure" modifier="None">
|
|
465
|
+
<BaseClass>OverheadStructureFunctionalAspect</BaseClass>
|
|
466
|
+
</ECEntityClass>
|
|
467
|
+
<ECEntityClass typeName="EquipmentStructureFunctionalAspect" displayLabel="Equipment Structure" modifier="None">
|
|
468
|
+
<BaseClass>OverheadStructureFunctionalAspect</BaseClass>
|
|
469
|
+
</ECEntityClass>
|
|
470
|
+
<ECEntityClass typeName="DeadEndStructureFunctionalAspect" displayLabel="Dead-end Structure" modifier="None">
|
|
471
|
+
<BaseClass>OverheadStructureFunctionalAspect</BaseClass>
|
|
472
|
+
</ECEntityClass>
|
|
473
|
+
<ECEntityClass typeName="PoleFunctionalAspect" displayLabel="Pole" description="Distribution pole used to support the overhead conductors and related equipment" modifier="None">
|
|
474
|
+
<BaseClass>OverheadStructureFunctionalAspect</BaseClass>
|
|
475
|
+
</ECEntityClass>
|
|
476
|
+
<ECEntityClass typeName="SupportWireFunctionalAspect" displayLabel="Support Wire" modifier="None">
|
|
477
|
+
<BaseClass>OverheadStructureFunctionalAspect</BaseClass>
|
|
478
|
+
</ECEntityClass>
|
|
479
|
+
<ECEntityClass typeName="CableSupportsFunctionalAspect" displayLabel="Cable Supports" modifier="None">
|
|
480
|
+
<BaseClass>StructureCustomFunctionalAspect</BaseClass>
|
|
481
|
+
</ECEntityClass>
|
|
482
|
+
<ECEntityClass typeName="GuyWireFunctionalAspect" displayLabel="Guy Wire" modifier="None">
|
|
483
|
+
<BaseClass>SupportWireFunctionalAspect</BaseClass>
|
|
484
|
+
</ECEntityClass>
|
|
485
|
+
<ECEntityClass typeName="GuyWireAccessoriesFunctionalAspect" displayLabel="Guy Wire Accessories" modifier="None">
|
|
486
|
+
<BaseClass>CableSupportsFunctionalAspect</BaseClass>
|
|
487
|
+
</ECEntityClass>
|
|
488
|
+
<ECEntityClass typeName="CableSpacerFunctionalAspect" displayLabel="Cable Spacer" modifier="None">
|
|
489
|
+
<BaseClass>CableSupportsFunctionalAspect</BaseClass>
|
|
490
|
+
</ECEntityClass>
|
|
491
|
+
<ECEntityClass typeName="CableFunctionalAspect" displayLabel="Cable" modifier="None">
|
|
492
|
+
<BaseClass>StructureCustomFunctionalAspect</BaseClass>
|
|
493
|
+
</ECEntityClass>
|
|
494
|
+
<ECEntityClass typeName="SpanGuyFunctionalAspect" displayLabel="Span Guy" modifier="None">
|
|
495
|
+
<BaseClass>CableFunctionalAspect</BaseClass>
|
|
496
|
+
</ECEntityClass>
|
|
497
|
+
<ECEntityClass typeName="DownGuyFunctionalAspect" displayLabel="Down Guy" modifier="None">
|
|
498
|
+
<BaseClass>CableFunctionalAspect</BaseClass>
|
|
499
|
+
</ECEntityClass>
|
|
500
|
+
<ECEntityClass typeName="UndergroundStructureFunctionalAspect" displayLabel="Underground Structure" modifier="None">
|
|
501
|
+
<BaseClass>StructureCustomFunctionalAspect</BaseClass>
|
|
502
|
+
</ECEntityClass>
|
|
503
|
+
<ECEntityClass typeName="VaultFunctionalAspect" displayLabel="Vault" modifier="None">
|
|
504
|
+
<BaseClass>UndergroundStructureFunctionalAspect</BaseClass>
|
|
505
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
506
|
+
</ECEntityClass>
|
|
507
|
+
<ECEntityClass typeName="ManholeFunctionalAspect" displayLabel="Manhole" modifier="None">
|
|
508
|
+
<BaseClass>UndergroundStructureFunctionalAspect</BaseClass>
|
|
509
|
+
</ECEntityClass>
|
|
510
|
+
<ECEntityClass typeName="AnchorCageFunctionalAspect" displayLabel="Anchor Cage" modifier="None">
|
|
511
|
+
<BaseClass>UndergroundStructureFunctionalAspect</BaseClass>
|
|
512
|
+
</ECEntityClass>
|
|
513
|
+
<ECEntityClass typeName="FastenersFunctionalAspect" displayLabel="Fasteners" modifier="None">
|
|
514
|
+
<BaseClass>StructureCustomFunctionalAspect</BaseClass>
|
|
515
|
+
</ECEntityClass>
|
|
516
|
+
<ECEntityClass typeName="SupportsFunctionalAspect" displayLabel="Supports" modifier="None">
|
|
517
|
+
<BaseClass>StructureCustomFunctionalAspect</BaseClass>
|
|
518
|
+
</ECEntityClass>
|
|
519
|
+
<ECEntityClass typeName="BoltFunctionalAspect" displayLabel="Bolt" modifier="None">
|
|
520
|
+
<BaseClass>FastenersFunctionalAspect</BaseClass>
|
|
521
|
+
</ECEntityClass>
|
|
522
|
+
<ECEntityClass typeName="WasherFunctionalAspect" displayLabel="Washer" modifier="None">
|
|
523
|
+
<BaseClass>FastenersFunctionalAspect</BaseClass>
|
|
524
|
+
</ECEntityClass>
|
|
525
|
+
<ECEntityClass typeName="NutsFunctionalAspect" displayLabel="Nuts" modifier="None">
|
|
526
|
+
<BaseClass>FastenersFunctionalAspect</BaseClass>
|
|
527
|
+
</ECEntityClass>
|
|
528
|
+
<ECEntityClass typeName="ScrewFunctionalAspect" displayLabel="Screw" modifier="None">
|
|
529
|
+
<BaseClass>FastenersFunctionalAspect</BaseClass>
|
|
530
|
+
</ECEntityClass>
|
|
531
|
+
<ECEntityClass typeName="LiftingLugsFunctionalAspect" displayLabel="Lifting Lugs" modifier="None">
|
|
532
|
+
<BaseClass>FastenersFunctionalAspect</BaseClass>
|
|
533
|
+
</ECEntityClass>
|
|
534
|
+
<ECEntityClass typeName="BusSupportFunctionalAspect" displayLabel="Bus Support" modifier="None">
|
|
535
|
+
<BaseClass>SupportsFunctionalAspect</BaseClass>
|
|
536
|
+
</ECEntityClass>
|
|
537
|
+
<ECEntityClass typeName="BracketFunctionalAspect" displayLabel="Bracket" modifier="None">
|
|
538
|
+
<BaseClass>SupportsFunctionalAspect</BaseClass>
|
|
539
|
+
</ECEntityClass>
|
|
540
|
+
<ECEntityClass typeName="UboltFunctionalAspect" displayLabel="U-Bolt" modifier="None">
|
|
541
|
+
<BaseClass>SupportsFunctionalAspect</BaseClass>
|
|
542
|
+
</ECEntityClass>
|
|
543
|
+
<ECEntityClass typeName="MountingKitFunctionalAspect" displayLabel="Mounting Kit" description="Additional components needed to mount equipment" modifier="None">
|
|
544
|
+
<BaseClass>SupportsFunctionalAspect</BaseClass>
|
|
545
|
+
</ECEntityClass>
|
|
546
|
+
<ECEntityClass typeName="PlatformFunctionalAspect" displayLabel="Platform" modifier="None">
|
|
547
|
+
<BaseClass>FoundationCustomFunctionalAspect</BaseClass>
|
|
548
|
+
</ECEntityClass>
|
|
549
|
+
<ECEntityClass typeName="EquipmentFoundationFunctionalAspect" displayLabel="Equipment Foundation" modifier="None">
|
|
550
|
+
<BaseClass>FoundationCustomFunctionalAspect</BaseClass>
|
|
551
|
+
</ECEntityClass>
|
|
552
|
+
<ECEntityClass typeName="StructureFoundationFunctionalAspect" displayLabel="Structure Foundation" modifier="None">
|
|
553
|
+
<BaseClass>FoundationCustomFunctionalAspect</BaseClass>
|
|
554
|
+
</ECEntityClass>
|
|
555
|
+
<ECEntityClass typeName="WalkingPlatformFunctionalAspect" displayLabel="Walking platform" modifier="None">
|
|
556
|
+
<BaseClass>PlatformFunctionalAspect</BaseClass>
|
|
557
|
+
</ECEntityClass>
|
|
558
|
+
<ECEntityClass typeName="SwitchOperatorPlatformFunctionalAspect" displayLabel="Switch Operator Platform" modifier="None">
|
|
559
|
+
<BaseClass>PlatformFunctionalAspect</BaseClass>
|
|
560
|
+
</ECEntityClass>
|
|
561
|
+
<ECEntityClass typeName="ElectricalBuildingFunctionalAspect" displayLabel="Electrical Building" modifier="None">
|
|
562
|
+
<BaseClass>SubstationCustomFunctionalAspect</BaseClass>
|
|
563
|
+
</ECEntityClass>
|
|
564
|
+
<ECEntityClass typeName="LVSwitchFunctionalAspect" displayLabel="LV Switches" modifier="None">
|
|
565
|
+
<BaseClass>ElectricalBuildingFunctionalAspect</BaseClass>
|
|
566
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
567
|
+
</ECEntityClass>
|
|
568
|
+
<ECEntityClass typeName="AudioVisualDeviceFunctionalAspect" displayLabel="Audio Visual Device" modifier="None">
|
|
569
|
+
<BaseClass>ElectricalBuildingFunctionalAspect</BaseClass>
|
|
570
|
+
</ECEntityClass>
|
|
571
|
+
<ECEntityClass typeName="CommunicationDeviceFunctionalAspect" displayLabel="Communication Device" modifier="None">
|
|
572
|
+
<BaseClass>ElectricalBuildingFunctionalAspect</BaseClass>
|
|
573
|
+
</ECEntityClass>
|
|
574
|
+
<ECEntityClass typeName="ElectricPanelFunctionalAspect" displayLabel="Electric Panel" modifier="None">
|
|
575
|
+
<BaseClass>ElectricalBuildingFunctionalAspect</BaseClass>
|
|
576
|
+
</ECEntityClass>
|
|
577
|
+
<ECEntityClass typeName="LVBatteryFunctionalAspect" displayLabel="Low Voltage Battery" description="A device in which electrical energy is stored and from which energy may be progressively released." modifier="None">
|
|
578
|
+
<BaseClass>ElectricalBuildingFunctionalAspect</BaseClass>
|
|
579
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
580
|
+
</ECEntityClass>
|
|
581
|
+
<ECEntityClass typeName="ConditionerDeviceFunctionalAspect" displayLabel="Conditioner Device" description="used to remove unwanted matter from an electric or electronic signal" modifier="None">
|
|
582
|
+
<BaseClass>ElectricalBuildingFunctionalAspect</BaseClass>
|
|
583
|
+
</ECEntityClass>
|
|
584
|
+
<ECEntityClass typeName="ElectricLoadTimeControlFunctionalAspect" displayLabel="Electric Load Time Control" description="A device that applies control to the provision or flow of electrical energy over time " modifier="None">
|
|
585
|
+
<BaseClass>ElectricalBuildingFunctionalAspect</BaseClass>
|
|
586
|
+
</ECEntityClass>
|
|
587
|
+
<ECEntityClass typeName="PowerOutletFunctionalAspect" displayLabel="Outlet" modifier="None">
|
|
588
|
+
<BaseClass>ElectricalBuildingFunctionalAspect</BaseClass>
|
|
589
|
+
</ECEntityClass>
|
|
590
|
+
<ECEntityClass typeName="FanFunctionalAspect" displayLabel="Fan" modifier="None">
|
|
591
|
+
<BaseClass>ElectricalBuildingFunctionalAspect</BaseClass>
|
|
592
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
593
|
+
<ECProperty propertyName="Phase" displayLabel="Phase" typeName="string" />
|
|
594
|
+
</ECEntityClass>
|
|
595
|
+
<ECEntityClass typeName="LightingFixtureFunctionalAspect" displayLabel="Lighting Fixture" modifier="None">
|
|
596
|
+
<BaseClass>ElectricalBuildingFunctionalAspect</BaseClass>
|
|
597
|
+
</ECEntityClass>
|
|
598
|
+
<ECEntityClass typeName="PowerBatteryFunctionalAspect" displayLabel="Power Battery" modifier="None">
|
|
599
|
+
<BaseClass>ElectricalBuildingFunctionalAspect</BaseClass>
|
|
600
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
601
|
+
<ECProperty propertyName="Phase" displayLabel="Phase" typeName="string" />
|
|
602
|
+
</ECEntityClass>
|
|
603
|
+
<ECEntityClass typeName="EnclosureFunctionalAspect" displayLabel="Enclosure" modifier="None">
|
|
604
|
+
<BaseClass>ElectricalBuildingFunctionalAspect</BaseClass>
|
|
605
|
+
</ECEntityClass>
|
|
606
|
+
<ECEntityClass typeName="SolarDeviceFunctionalAspect" displayLabel="Solar Device" modifier="None">
|
|
607
|
+
<BaseClass>ElectricalBuildingFunctionalAspect</BaseClass>
|
|
608
|
+
</ECEntityClass>
|
|
609
|
+
<ECEntityClass typeName="RacewayFunctionalAspect" displayLabel="Raceway" modifier="None">
|
|
610
|
+
<BaseClass>SubstationCustomFunctionalAspect</BaseClass>
|
|
611
|
+
</ECEntityClass>
|
|
612
|
+
<ECEntityClass typeName="CoverFunctionalAspect" displayLabel="Cover" modifier="None">
|
|
613
|
+
<BaseClass>EnclosureFunctionalAspect</BaseClass>
|
|
614
|
+
</ECEntityClass>
|
|
615
|
+
<ECEntityClass typeName="CabinetFunctionalAspect" displayLabel="Cabinet" modifier="None">
|
|
616
|
+
<BaseClass>EnclosureFunctionalAspect</BaseClass>
|
|
617
|
+
</ECEntityClass>
|
|
618
|
+
<ECEntityClass typeName="GasketFunctionalAspect" displayLabel="Gasket" modifier="None">
|
|
619
|
+
<BaseClass>EnclosureFunctionalAspect</BaseClass>
|
|
620
|
+
</ECEntityClass>
|
|
621
|
+
<ECEntityClass typeName="SecondaryCutOutFunctionalAspect" displayLabel="Secondary Cut Out" modifier="None">
|
|
622
|
+
<BaseClass>EnclosureFunctionalAspect</BaseClass>
|
|
623
|
+
</ECEntityClass>
|
|
624
|
+
<ECEntityClass typeName="PanelboardAssemblyFunctionalAspect" displayLabel="Panel Board Assembly" modifier="None">
|
|
625
|
+
<BaseClass>EnclosureFunctionalAspect</BaseClass>
|
|
626
|
+
</ECEntityClass>
|
|
627
|
+
<ECEntityClass typeName="PullBoxFunctionalAspect" displayLabel="Pull Box" modifier="None">
|
|
628
|
+
<BaseClass>EnclosureFunctionalAspect</BaseClass>
|
|
629
|
+
</ECEntityClass>
|
|
630
|
+
<ECEntityClass typeName="JunctionBoxFunctionalAspect" displayLabel="Junction Box" description="A point where one or more conducting equipments are connected with zero resistance." modifier="None">
|
|
631
|
+
<BaseClass>EnclosureFunctionalAspect</BaseClass>
|
|
632
|
+
<ECProperty propertyName="EquipmentDefinitionCode" displayLabel="Equipment Definition Code" typeName="string" />
|
|
633
|
+
</ECEntityClass>
|
|
634
|
+
<ECEntityClass typeName="OutletBodyFunctionalAspect" displayLabel="Outlet Body" modifier="None">
|
|
635
|
+
<BaseClass>EnclosureFunctionalAspect</BaseClass>
|
|
636
|
+
</ECEntityClass>
|
|
637
|
+
<ECEntityClass typeName="CableTrenchFunctionalAspect" displayLabel="Cable Trench" modifier="None">
|
|
638
|
+
<BaseClass>RacewayFunctionalAspect</BaseClass>
|
|
639
|
+
<ECProperty propertyName="NumberOfCables" displayLabel="Number Of Cables" typeName="string" />
|
|
640
|
+
</ECEntityClass>
|
|
641
|
+
<ECEntityClass typeName="DuctbankFunctionalAspect" displayLabel="Duct bank" modifier="None">
|
|
642
|
+
<BaseClass>RacewayFunctionalAspect</BaseClass>
|
|
643
|
+
<ECProperty propertyName="NumberOfCables" displayLabel="Number Of Cables" typeName="string" />
|
|
644
|
+
</ECEntityClass>
|
|
645
|
+
<ECEntityClass typeName="CableTrayFunctionalAspect" displayLabel="Cable Tray" modifier="None">
|
|
646
|
+
<BaseClass>RacewayFunctionalAspect</BaseClass>
|
|
647
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
648
|
+
<ECProperty propertyName="PercentFill" displayLabel="Percent Filled" typeName="string" />
|
|
649
|
+
<ECProperty propertyName="NumberOfCables" displayLabel="Number Of Cables" typeName="string" />
|
|
650
|
+
</ECEntityClass>
|
|
651
|
+
<ECEntityClass typeName="CableLadderFunctionalAspect" displayLabel="Cable Ladder" modifier="None">
|
|
652
|
+
<BaseClass>RacewayFunctionalAspect</BaseClass>
|
|
653
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
654
|
+
<ECProperty propertyName="PercentFill" displayLabel="Percent Filled" typeName="string" />
|
|
655
|
+
<ECProperty propertyName="NumberOfCables" displayLabel="Number Of Cables" typeName="string" />
|
|
656
|
+
</ECEntityClass>
|
|
657
|
+
<ECEntityClass typeName="CableLadderFittingFunctionalAspect" displayLabel="Cable Ladder Fitting" modifier="None">
|
|
658
|
+
<BaseClass>RacewayFunctionalAspect</BaseClass>
|
|
659
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
660
|
+
<ECProperty propertyName="PercentFill" displayLabel="Percent Filled" typeName="string" />
|
|
661
|
+
<ECProperty propertyName="NumberOfCables" displayLabel="Number Of Cables" typeName="string" />
|
|
662
|
+
</ECEntityClass>
|
|
663
|
+
<ECEntityClass typeName="CableTrayFittingsFunctionalAspect" displayLabel="Cable Tray Fittings" modifier="None">
|
|
664
|
+
<BaseClass>RacewayFunctionalAspect</BaseClass>
|
|
665
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
666
|
+
<ECProperty propertyName="PercentFill" displayLabel="Percent Filled" typeName="string" />
|
|
667
|
+
<ECProperty propertyName="NumberOfCables" displayLabel="Number Of Cables" typeName="string" />
|
|
668
|
+
</ECEntityClass>
|
|
669
|
+
<ECEntityClass typeName="CableTrayCoverFunctionalAspect" displayLabel="Cable Tray Cover" modifier="None">
|
|
670
|
+
<BaseClass>RacewayFunctionalAspect</BaseClass>
|
|
671
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
672
|
+
<ECProperty propertyName="PercentFill" displayLabel="Percent Filled" typeName="string" />
|
|
673
|
+
</ECEntityClass>
|
|
674
|
+
<ECEntityClass typeName="WirewayFunctionalAspect" displayLabel="Wireway" modifier="None">
|
|
675
|
+
<BaseClass>RacewayFunctionalAspect</BaseClass>
|
|
676
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
677
|
+
<ECProperty propertyName="PercentFill" displayLabel="Percent Filled" typeName="string" />
|
|
678
|
+
<ECProperty propertyName="NumberOfCables" displayLabel="Number Of Cables" typeName="string" />
|
|
679
|
+
</ECEntityClass>
|
|
680
|
+
<ECEntityClass typeName="ConduitFittingFunctionalAspect" displayLabel="Conduit Fittings" modifier="None">
|
|
681
|
+
<BaseClass>RacewayFunctionalAspect</BaseClass>
|
|
682
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
683
|
+
<ECProperty propertyName="PercentFill" displayLabel="Percent Filled" typeName="string" />
|
|
684
|
+
<ECProperty propertyName="NumberOfCables" displayLabel="Number Of Cables" typeName="string" />
|
|
685
|
+
</ECEntityClass>
|
|
686
|
+
<ECEntityClass typeName="ConduitFunctionalAspect" displayLabel="Conduit" modifier="None">
|
|
687
|
+
<BaseClass>RacewayFunctionalAspect</BaseClass>
|
|
688
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
689
|
+
<ECProperty propertyName="PercentFill" displayLabel="Percent Filled" typeName="string" />
|
|
690
|
+
<ECProperty propertyName="NumberOfCables" displayLabel="Number Of Cables" typeName="string" />
|
|
691
|
+
</ECEntityClass>
|
|
692
|
+
<ECEntityClass typeName="MiscellaneousFunctionalAspect" displayLabel="Miscellaneous" modifier="None">
|
|
693
|
+
<BaseClass>SubstationCustomFunctionalAspect</BaseClass>
|
|
694
|
+
</ECEntityClass>
|
|
695
|
+
<ECEntityClass typeName="FenceFunctionalAspect" displayLabel="Fence" modifier="None">
|
|
696
|
+
<BaseClass>MiscellaneousFunctionalAspect</BaseClass>
|
|
697
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
698
|
+
</ECEntityClass>
|
|
699
|
+
<ECEntityClass typeName="GateFunctionalAspect" displayLabel="Gate" modifier="None">
|
|
700
|
+
<BaseClass>MiscellaneousFunctionalAspect</BaseClass>
|
|
701
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
702
|
+
</ECEntityClass>
|
|
703
|
+
<ECEntityClass typeName="ControlBuildingFunctionalAspect" displayLabel="Control Building" modifier="None">
|
|
704
|
+
<BaseClass>MiscellaneousFunctionalAspect</BaseClass>
|
|
705
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
706
|
+
</ECEntityClass>
|
|
707
|
+
<ECEntityClass typeName="OilContainmentSystemFunctionalAspect" displayLabel="Oil Containment System" modifier="None">
|
|
708
|
+
<BaseClass>MiscellaneousFunctionalAspect</BaseClass>
|
|
709
|
+
<ECProperty propertyName="YearOfManufacture" displayLabel="Year Of Manufacture" typeName="dateTime" />
|
|
710
|
+
</ECEntityClass>
|
|
711
|
+
<ECEntityClass typeName="PhysicalSafetyBarrierFunctionalAspect" displayLabel="Physical Safety Barrier" modifier="None">
|
|
712
|
+
<BaseClass>MiscellaneousFunctionalAspect</BaseClass>
|
|
713
|
+
</ECEntityClass>
|
|
714
|
+
<ECEntityClass typeName="GeneralHardwareFunctionalAspect" displayLabel="General Hardware" modifier="None">
|
|
715
|
+
<BaseClass>MiscellaneousFunctionalAspect</BaseClass>
|
|
716
|
+
</ECEntityClass>
|
|
717
|
+
<ECEntityClass typeName="NameplateFunctionalAspect" displayLabel="Nameplate" description="Mounted on the equipment, and contains most relevant equipment attributes. Can be provided by manufacturer or created by utility using the data from design." modifier="None">
|
|
718
|
+
<BaseClass>MiscellaneousFunctionalAspect</BaseClass>
|
|
719
|
+
</ECEntityClass>
|
|
720
|
+
<ECEntityClass typeName="TerrainFunctionalAspect" displayLabel="Terrain" description="DTM Terrain" modifier="None">
|
|
721
|
+
<BaseClass>MiscellaneousFunctionalAspect</BaseClass>
|
|
722
|
+
</ECEntityClass>
|
|
723
|
+
<ECEntityClass typeName="AnimalGuardFunctionalAspect" displayLabel="Animal Guard" modifier="None">
|
|
724
|
+
<BaseClass>PhysicalSafetyBarrierFunctionalAspect</BaseClass>
|
|
725
|
+
</ECEntityClass>
|
|
726
|
+
<ECEntityClass typeName="FireBarrierFunctionalAspect" displayLabel="Fire Barrier" modifier="None">
|
|
727
|
+
<BaseClass>PhysicalSafetyBarrierFunctionalAspect</BaseClass>
|
|
728
|
+
</ECEntityClass>
|
|
729
|
+
<ECEntityClass typeName="VehicleBarrierFunctionalAspect" displayLabel="Vehicle Barrier" modifier="None">
|
|
730
|
+
<BaseClass>PhysicalSafetyBarrierFunctionalAspect</BaseClass>
|
|
731
|
+
</ECEntityClass>
|
|
732
|
+
</ECSchema>
|
package/package.json
ADDED
|
@@ -0,0 +1,20 @@
|
|
|
1
|
+
{
|
|
2
|
+
"name": "@bentley/substation-functional-custom-schema",
|
|
3
|
+
"license": "MIT",
|
|
4
|
+
"version": "1.0.5-dev.1",
|
|
5
|
+
"homepage": "https://www.itwinjs.org/",
|
|
6
|
+
"keywords": [
|
|
7
|
+
"Bentley",
|
|
8
|
+
"BIS",
|
|
9
|
+
"iModel"
|
|
10
|
+
],
|
|
11
|
+
"description": "SubstationFunctionalCustom BIS Domains",
|
|
12
|
+
"author": {
|
|
13
|
+
"name": "Bentley Systems, Inc.",
|
|
14
|
+
"url": "http://www.bentley.com"
|
|
15
|
+
},
|
|
16
|
+
"exports" : {
|
|
17
|
+
"./SubstationFunctionalCustom.ecschema.xml": "./SubstationFunctionalCustom.ecschema.xml",
|
|
18
|
+
"./SubstationFunctionalCustom.ecschema.json": "./SubstationFunctionalCustom.ecschema.json"
|
|
19
|
+
}
|
|