waterfurnace_aurora 1.2.2 → 1.3.2

Sign up to get free protection for your applications and to get access to all the features.
checksums.yaml CHANGED
@@ -1,7 +1,7 @@
1
1
  ---
2
2
  SHA256:
3
- metadata.gz: caf73ece152211ae227b1b628572d0dc43936b600c2d41a0a534178dc74385cd
4
- data.tar.gz: d5ed42012eb9fc1e2aca036914cfd538e3342df0f34342e2c9c37d18ad6cce29
3
+ metadata.gz: e09071363ccbd485b256f1e79c2f363e03bc3b2d4d94af9149e50295d0f38d38
4
+ data.tar.gz: a092a806f450e77559de1899173b9b4cb63349a73220c17af6f67382daa30280
5
5
  SHA512:
6
- metadata.gz: eaacad438ac440a004f8611b907f9eff3e453193884627178dc8608f66ff29640f5e355993069b34d83ef796cb6169f0d25bc4a1b06103a44194d339618f08a6
7
- data.tar.gz: 00e3dfeba4fc12ec7804fcde37241ff93de9f60bb91f03e7182f309de383890454f83f959aeacfd5a3924874bd56ca1c5aaa853ca52b05abd56fd894aa3d0f38
6
+ metadata.gz: 7e915833530cbf2d78f9e4de98dda9efbcdd0c4eca386716ef4d455e030a28d1847c38d1df379773bff24581cfd4dee765e86bf6d61d5eec706e20dd8bafd4f8
7
+ data.tar.gz: 7cb9b9b8ca0b3f17a88cf2dc66c937c52a396eb52cfd955fb311732a432e7b648c5514b12b14faafe99f76d19243e837b24f2dade224f6177c14a1c543e60e01
@@ -282,6 +282,19 @@ class MQTTBridge
282
282
  unit: "W",
283
283
  hass: { sensor: { device_class: :power,
284
284
  state_class: :measurement } })
285
+ node.property("heat-of-extraction",
286
+ "Heat of Extraction",
287
+ :integer,
288
+ @abc.compressor.heat_of_extraction,
289
+ unit: "Btuh",
290
+ hass: { sensor: { state_class: :measurement } })
291
+ node.property("heat-of-rejection",
292
+ "Heat of Rejection",
293
+ :integer,
294
+ @abc.compressor.heat_of_rejection,
295
+ unit: "Btuh",
296
+ hass: { sensor: { state_class: :measurement } })
297
+
285
298
  end
286
299
 
287
300
  next unless @abc.compressor.is_a?(Aurora::Compressor::VSDrive)
@@ -372,10 +385,18 @@ class MQTTBridge
372
385
  hass: { sensor: { device_class: :temperature,
373
386
  state_class: :measurement,
374
387
  entity_category: :diagnostic } })
388
+ node.property("subcool-temperature",
389
+ "SubCool Temperature",
390
+ :float,
391
+ @abc.compressor.subcool_temperature,
392
+ unit: "°F",
393
+ hass: { sensor: { device_class: :temperature,
394
+ state_class: :measurement,
395
+ entity_category: :diagnostic } })
375
396
  node.property("eev-open-percentage",
376
397
  "Electronic Expansion Valve Open Percentage",
377
398
  :integer,
378
- @abc.compressor.eev_percentage,
399
+ @abc.compressor.eev_open_percentage,
379
400
  unit: "%",
380
401
  format: 0..100,
381
402
  hass: { sensor: { state_class: :measurement,
@@ -437,8 +458,7 @@ class MQTTBridge
437
458
 
438
459
  next unless @abc.blower.is_a?(Aurora::Blower::ECM)
439
460
 
440
- presets = %w[blower-only aux-heat]
441
- presets.concat %w[low-compressor high-compressor] unless @abc.iz2?
461
+ presets = %w[blower-only aux-heat low-compressor high-compressor]
442
462
  presets.each do |setting|
443
463
  field = "#{setting.tr("-", "_")}_speed"
444
464
  node.property("#{setting}-speed",
@@ -5,7 +5,12 @@ require "aurora/component"
5
5
  module Aurora
6
6
  module Compressor
7
7
  class GenericCompressor < Component
8
- attr_reader :speed, :watts, :cooling_liquid_line_temperature, :saturated_condensor_discharge_temperature
8
+ attr_reader :speed,
9
+ :watts,
10
+ :cooling_liquid_line_temperature,
11
+ :saturated_condensor_discharge_temperature,
12
+ :heat_of_extraction,
13
+ :heat_of_rejection
9
14
 
10
15
  def initialize(abc, stages)
11
16
  super(abc)
@@ -22,7 +27,7 @@ module Aurora
22
27
 
23
28
  def registers_to_read
24
29
  result = [19, 1134]
25
- result << (1146..1147) if abc.energy_monitoring?
30
+ result.concat([1146..1147, 1154..1157]) if abc.energy_monitoring?
26
31
  result
27
32
  end
28
33
 
@@ -37,7 +42,12 @@ module Aurora
37
42
  end
38
43
  @cooling_liquid_line_temperature = registers[19]
39
44
  @saturated_condensor_discharge_temperature = registers[1134]
40
- @watts = registers[1146] if abc.energy_monitoring?
45
+
46
+ return unless abc.energy_monitoring?
47
+
48
+ @watts = registers[1146]
49
+ @heat_of_extraction = registers[1154]
50
+ @heat_of_rejection = registers[1156]
41
51
  end
42
52
  end
43
53
 
@@ -54,7 +64,8 @@ module Aurora
54
64
  :suction_temperature,
55
65
  :saturated_evaporator_discharge_temperature,
56
66
  :superheat_temperature,
57
- :eev_percentage
67
+ :subcool_temperature,
68
+ :eev_open_percentage
58
69
 
59
70
  def initialize(abc)
60
71
  super(abc, 12)
@@ -65,7 +76,7 @@ module Aurora
65
76
  end
66
77
 
67
78
  def registers_to_read
68
- result = super + [209, 3000..3001, 3322..3327, 3522, 3524, 3808, 3903..3906]
79
+ result = super + [209, 1135..1136, 3000..3001, 3322..3327, 3522, 3524, 3808, 3903..3906]
69
80
  result << 564 if abc.iz2?
70
81
  result
71
82
  end
@@ -82,10 +93,11 @@ module Aurora
82
93
  @drive_temperature = registers[3327]
83
94
  @inverter_temperature = registers[3522]
84
95
  @fan_speed = registers[3524]
85
- @eev_percentage = registers[3808]
96
+ @eev_open_percentage = registers[3808]
86
97
  @suction_temperature = registers[3903]
87
98
  @saturated_evaporator_discharge_temperature = registers[3905]
88
99
  @superheat_temperature = registers[3906]
100
+ @subcool_temperature = registers[registers[30].include?(:rv) ? 1136 : 1135]
89
101
 
90
102
  @iz2_desired_speed = registers[564] if abc.iz2?
91
103
  end
@@ -44,10 +44,11 @@ module Aurora
44
44
  totals
45
45
  end
46
46
 
47
+ NEGATABLE = ->(v) { v & 0x8000 == 0x8000 ? v - 0x10000 : v }
47
48
  TO_HUNDREDTHS = ->(v) { v.to_f / 100 }
48
49
  TO_TENTHS = ->(v) { v.to_f / 10 }
50
+ TO_SIGNED_TENTHS = ->(v) { NEGATABLE.call(v).to_f / 10 }
49
51
  TO_LAST_LOCKOUT = ->(v) { v & 0x8000 == 0x8000 ? v & 0x7fff : nil }
50
- NEGATABLE = ->(v) { v & 0x8000 == 0x8000 ? v - 0x10000 : v }
51
52
 
52
53
  def from_bitmask(value, flags)
53
54
  result = []
@@ -59,11 +60,16 @@ module Aurora
59
60
  result
60
61
  end
61
62
 
62
- def to_int32(registers, idx)
63
+ def to_uint32(registers, idx)
63
64
  Aurora&.logger&.warn("Missing register #{idx + 1}") unless registers[idx + 1]
64
65
  (registers[idx] << 16) + registers[idx + 1]
65
66
  end
66
67
 
68
+ def to_int32(registers, idx)
69
+ v = to_uint32(registers, idx)
70
+ v & 0x80000000 == 0x80000000 ? v - 0x100000000 : v
71
+ end
72
+
67
73
  def to_string(registers, idx, length)
68
74
  (idx...(idx + length)).map do |i|
69
75
  next "\ufffd" unless registers[i] # missing data? add unicode invalid character
@@ -488,18 +494,20 @@ module Aurora
488
494
  REGISTER_CONVERTERS = {
489
495
  TO_HUNDREDTHS => [2, 3, 417, 418, 801, 804, 807, 813, 816, 817, 819, 820, 825, 828],
490
496
  method(:dipswitch_settings) => [4, 33],
491
- TO_TENTHS => [19, 20, 401, 419, 501, 502, 567, 740, 745, 746, 747, 900, 901, 903,
492
- 1105, 1106, 1107, 1108, 1109, 1110, 1111, 1112, 1113, 1114, 1115, 1116, 1117, 1119, 1124, 1125, 1134,
493
- 3322, 3323, 3325, 3326, 3327, 3330, 3522, 3903, 3905, 3906,
497
+ TO_TENTHS => [401, 419, 745, 746, 901,
498
+ 1105, 1106, 1107, 1108, 1115, 1116, 1117, 1119,
499
+ 3322, 3323,
494
500
  12_619, 12_620,
495
501
  21_203, 21_204,
496
502
  21_212, 21_213,
497
503
  21_221, 21_222,
498
504
  21_230, 22_131,
499
505
  21_239, 21_240,
500
- 21_248, 21_249,
501
- 31_003,
502
- 31_007, 31_010, 31_013, 31_016, 31_019, 31_022],
506
+ 21_248, 21_249],
507
+ TO_SIGNED_TENTHS => [19, 20, 501, 502, 567, 740, 747, 900, 903,
508
+ 1109, 1110, 1111, 1112, 1113, 1114, 1124, 1125, 1134, 1135, 1136,
509
+ 3325, 3326, 3327, 3330, 3522, 3903, 3905, 3906,
510
+ 31_003, 31_007, 31_010, 31_013, 31_016, 31_019, 31_022],
503
511
  TO_LAST_LOCKOUT => [26],
504
512
  ->(v) { from_bitmask(v, SYSTEM_OUTPUTS) } => [27, 30],
505
513
  ->(v) { from_bitmask(v, SYSTEM_INPUTS) } => [28],
@@ -530,8 +538,8 @@ module Aurora
530
538
  ->(v) { COMPONENT_STATUS[v] } => [800, 803, 806, 812, 815, 818, 824, 827],
531
539
  method(:axb_inputs) => [1103],
532
540
  ->(v) { from_bitmask(v, AXB_OUTPUTS) } => [1104],
533
- ->(v) { TO_TENTHS.call(NEGATABLE.call(v)) } => [1135, 1136],
534
- method(:to_int32) => [1146, 1148, 1150, 1152, 1154, 1156, 1164, 3422, 3424],
541
+ method(:to_uint32) => [1146, 1148, 1150, 1152, 1164, 3422, 3424],
542
+ method(:to_int32) => [1154, 1156],
535
543
  method(:manual_operation) => [3002],
536
544
  method(:thermostat_configuration2) => [12_006],
537
545
  ->(v) { HEATING_MODE[v] } => [12_606, 21_202, 21_211, 21_220, 21_229, 21_238, 21_247],
@@ -1,5 +1,5 @@
1
1
  # frozen_string_literal: true
2
2
 
3
3
  module Aurora
4
- VERSION = "1.2.2"
4
+ VERSION = "1.3.2"
5
5
  end
metadata CHANGED
@@ -1,14 +1,14 @@
1
1
  --- !ruby/object:Gem::Specification
2
2
  name: waterfurnace_aurora
3
3
  version: !ruby/object:Gem::Version
4
- version: 1.2.2
4
+ version: 1.3.2
5
5
  platform: ruby
6
6
  authors:
7
7
  - Cody Cutrer
8
8
  autorequire:
9
9
  bindir: exe
10
10
  cert_chain: []
11
- date: 2022-02-03 00:00:00.000000000 Z
11
+ date: 2022-02-14 00:00:00.000000000 Z
12
12
  dependencies:
13
13
  - !ruby/object:Gem::Dependency
14
14
  name: ccutrer-serialport