waterfurnace_aurora 1.2.0 → 1.2.1

Sign up to get free protection for your applications and to get access to all the features.
checksums.yaml CHANGED
@@ -1,7 +1,7 @@
1
1
  ---
2
2
  SHA256:
3
- metadata.gz: d9f0f7d0f0c846720df96f8889d1d5952ece7e0dbabea3431484f4efbff06f5a
4
- data.tar.gz: e82bc4400c9543322debe51a21da1dea54d07a673f7302e5ec2a2910e8229714
3
+ metadata.gz: b5bf3ed7c4a651515bad13558d23844c6108ce6ac266b17772e786201ead3255
4
+ data.tar.gz: 7aee648a7e8fdee5efee31ead44ad05a18f8c9df4997f485ff10bf4366f8e887
5
5
  SHA512:
6
- metadata.gz: eddd8d24b22c6a1c1c64c8fdd29f79c00c76145252b5ddbcd08cf2c7edd0f03182439cb9cf511041bc1a789823b421eefcb3ac90d3f5c72e6fcb54fdf88dc60d
7
- data.tar.gz: 76b06de5f2ff979a0c4eaaf05998d4856aa01f491f80fc224870920319d9abda0c89c800a221d532f3c2ccb850c01217570d3f72b447af221186da18ed81fa84
6
+ metadata.gz: 448487c7ee50e3d185c9a8e326806052fbd0c85d0e57a546d65c9a9d1710ea752ceee91e4bc685ca0c7ee256bd6da3bd19d58536d7460861fd1c96ee33be0000
7
+ data.tar.gz: 934d63154af6a18b32d8f996db99c46a8201336cd55ae65781da1eb54700d5e65bb40b9d8c3b99edd56801953eaa330b18f6bf71faa1764bf46d2abc7d6ace2b
@@ -286,6 +286,12 @@ class MQTTBridge
286
286
 
287
287
  next unless @abc.compressor.is_a?(Aurora::Compressor::VSDrive)
288
288
 
289
+ node.property("desired-speed",
290
+ "Desired Speed",
291
+ :integer,
292
+ @abc.compressor.desired_speed,
293
+ format: @abc.compressor.speed_range,
294
+ hass: { sensor: { state_class: :measurement } })
289
295
  node.property("ambient-temperature",
290
296
  "Ambient Temperature",
291
297
  :float,
@@ -366,10 +372,10 @@ class MQTTBridge
366
372
  hass: { sensor: { device_class: :temperature,
367
373
  state_class: :measurement,
368
374
  entity_category: :diagnostic } })
369
- node.property("superheat-percentage",
370
- "SuperHeat Percentage",
375
+ node.property("eev-percentage",
376
+ "EEV Open Percent Open",
371
377
  :integer,
372
- @abc.compressor.superheat_percentage,
378
+ @abc.compressor.eev_percentage,
373
379
  unit: "%",
374
380
  format: 0..100,
375
381
  hass: { sensor: { state_class: :measurement,
@@ -45,6 +45,7 @@ module Aurora
45
45
  attr_reader :drive_temperature,
46
46
  :inverter_temperature,
47
47
  :ambient_temperature,
48
+ :desired_speed,
48
49
  :iz2_desired_speed,
49
50
  :fan_speed,
50
51
  :discharge_pressure,
@@ -53,7 +54,7 @@ module Aurora
53
54
  :suction_temperature,
54
55
  :saturated_evaporator_discharge_temperature,
55
56
  :superheat_temperature,
56
- :superheat_percentage
57
+ :eev_percentage
57
58
 
58
59
  def initialize(abc)
59
60
  super(abc, 12)
@@ -64,7 +65,7 @@ module Aurora
64
65
  end
65
66
 
66
67
  def registers_to_read
67
- result = super + [209, 3001, 3322..3327, 3522, 3524, 3808, 3903..3906]
68
+ result = super + [209, 3000..3001, 3322..3327, 3522, 3524, 3808, 3903..3906]
68
69
  result << 564 if abc.iz2?
69
70
  result
70
71
  end
@@ -72,6 +73,7 @@ module Aurora
72
73
  def refresh(registers)
73
74
  super
74
75
 
76
+ @desired_speed = registers[3000]
75
77
  @speed = registers[3001]
76
78
  @discharge_pressure = registers[3322]
77
79
  @suction_pressure = registers[3323]
@@ -80,7 +82,7 @@ module Aurora
80
82
  @drive_temperature = registers[3327]
81
83
  @inverter_temperature = registers[3522]
82
84
  @fan_speed = registers[3524]
83
- @superheat_percentage = registers[3808]
85
+ @eev_percentage = registers[3808]
84
86
  @suction_temperature = registers[3903]
85
87
  @saturated_evaporator_discharge_temperature = registers[3905]
86
88
  @superheat_temperature = registers[3906]
@@ -859,7 +859,11 @@ module Aurora
859
859
  1154 => "Heat of Extraction",
860
860
  1156 => "Heat of Rejection",
861
861
  1164 => "Pump Watts",
862
+ # this combines thermostat/iz2 desired speed with manual operation override
862
863
  3000 => "Compressor Speed Desired",
864
+ # this shows the actual speed
865
+ # it can differ from desired during a ramp to the desired speed, or
866
+ # the periodic ramp up to speed 6 that's not visible in the desired speed
863
867
  3001 => "Compressor Speed Actual",
864
868
  3002 => "Manual Operation",
865
869
  3027 => "Compressor Speed",
@@ -885,7 +889,7 @@ module Aurora
885
889
  3523 => "VS Drive UDC Voltage",
886
890
  3524 => "VS Drive Fan Speed",
887
891
  3804 => "VS Drive Details (EEV2 Ctl)",
888
- 3808 => "VS Drive SuperHeat Percent",
892
+ 3808 => "VS Drive EEV2 % Open",
889
893
  3903 => "VS Drive Suction Temperature",
890
894
  3904 => "VS Drive Leaving Air Temperature?",
891
895
  3905 => "VS Drive Saturated Evaporator Discharge Temperature",
@@ -1,5 +1,5 @@
1
1
  # frozen_string_literal: true
2
2
 
3
3
  module Aurora
4
- VERSION = "1.2.0"
4
+ VERSION = "1.2.1"
5
5
  end
metadata CHANGED
@@ -1,14 +1,14 @@
1
1
  --- !ruby/object:Gem::Specification
2
2
  name: waterfurnace_aurora
3
3
  version: !ruby/object:Gem::Version
4
- version: 1.2.0
4
+ version: 1.2.1
5
5
  platform: ruby
6
6
  authors:
7
7
  - Cody Cutrer
8
8
  autorequire:
9
9
  bindir: exe
10
10
  cert_chain: []
11
- date: 2022-02-01 00:00:00.000000000 Z
11
+ date: 2022-02-03 00:00:00.000000000 Z
12
12
  dependencies:
13
13
  - !ruby/object:Gem::Dependency
14
14
  name: ccutrer-serialport