waterfurnace_aurora 0.6.2 → 0.7.1

Sign up to get free protection for your applications and to get access to all the features.
checksums.yaml CHANGED
@@ -1,7 +1,7 @@
1
1
  ---
2
2
  SHA256:
3
- metadata.gz: 2e4165620d720c36045b8f8aa29a553d6de03aa555ac9083f5491ea47087ee4b
4
- data.tar.gz: 8532386c1f010471d2d99a2318540eada6a9aa670f9efd1251f632c2db12c11d
3
+ metadata.gz: 8cb9189b26a420442c7cb7208ac5c955d6be8ed9296a73f62df320eec5ca69b4
4
+ data.tar.gz: da661eea9277eef4f927e7714bf384f4377930a5e49df52632d7ed457df10fb5
5
5
  SHA512:
6
- metadata.gz: 023b5180a5a35524670d954be623a6b806d0be96070eb26c6820277544948316583d4b698843bd937f8e0c583f933398dcb6a0c91356872967092cfcb6ff4955
7
- data.tar.gz: 15033ae835c70fc3532ddaadef932e0498bb8504938066cfd9fbfca494772b5642f6e21b6483ca52499db5baf506d03aeb458b3a1cf899970eb128fd8fc4cf26
6
+ metadata.gz: 7a80d7049be630d2531e6acfa4d0a56693377555f46a102cb742e1c9e947454f67756ae0f8ca9c146a99e8bbf9acc32db821eae65aa57d4186ca9a5bdfe5280f
7
+ data.tar.gz: 6fcc21eea70ab2a9a8d7169c68528b01635a2e16acdff5601feed205c80b816f398323cb24c77ec7d3df1193c121247302cedd4fd844312015f26be1959a2c81
data/exe/aurora_mock CHANGED
@@ -38,7 +38,7 @@ r = slave1.holding_registers = slave2.holding_registers = slave255.holding_regis
38
38
  registers = YAML.safe_load(File.read(ARGV[2]))
39
39
  registers.each { |(k, v)| r[k] = v }
40
40
 
41
- server1.request_callback = lambda { |uid, func, req|
41
+ server1.request_callback = lambda do |uid, func, req|
42
42
  if func == 68
43
43
  puts "===== no idea to #{uid}: #{req.inspect}"
44
44
  elsif func == 67
@@ -54,9 +54,9 @@ server1.request_callback = lambda { |uid, func, req|
54
54
  else
55
55
  puts "**** new func #{func}"
56
56
  end
57
- }
57
+ end
58
58
 
59
- server1.response_callback = lambda { |uid, func, res, req|
59
+ server1.response_callback = lambda do |uid, func, res, req|
60
60
  if func == 3 && res.is_a?(Array) && req
61
61
  unless req[:quant] == res.length
62
62
  puts "wrong number of results"
@@ -88,7 +88,7 @@ server1.response_callback = lambda { |uid, func, res, req|
88
88
  else
89
89
  puts "**** new func #{func}"
90
90
  end
91
- }
91
+ end
92
92
 
93
93
  server2.start
94
94
  server1.send(:serve, server1.instance_variable_get(:@sp))
data/exe/aurora_monitor CHANGED
@@ -79,7 +79,7 @@ diff_and_print = lambda do |registers|
79
79
  last_registers = new_registers
80
80
  end
81
81
 
82
- server.request_callback = lambda { |uid, func, req|
82
+ server.request_callback = lambda do |uid, func, req|
83
83
  if func == 6
84
84
  puts "#{Time.now} ===== write register to #{uid}:"
85
85
  registers = { req[:addr] => req[:val] }
@@ -104,9 +104,9 @@ server.request_callback = lambda { |uid, func, req|
104
104
  else
105
105
  puts "#{Time.now} **** new func #{func}"
106
106
  end
107
- }
107
+ end
108
108
 
109
- server.response_callback = lambda { |uid, func, res, req|
109
+ server.response_callback = lambda do |uid, func, res, req|
110
110
  if func == 3 && res.is_a?(Array) && req
111
111
  unless req[:quant] == res.length
112
112
  puts "wrong number of results"
@@ -138,7 +138,7 @@ server.response_callback = lambda { |uid, func, res, req|
138
138
  else
139
139
  puts "#{Time.now} **** new func #{func}"
140
140
  end
141
- }
141
+ end
142
142
 
143
143
  server.send(:serve, server.instance_variable_get(:@sp))
144
144
  loop { nil }
@@ -3,6 +3,7 @@
3
3
 
4
4
  require "aurora"
5
5
  require "homie-mqtt"
6
+ require "mqtt/home_assistant"
6
7
  require "ccutrer-serialport"
7
8
  require "uri"
8
9
  require "optparse"
@@ -79,7 +80,7 @@ class MQTTBridge
79
80
  end
80
81
  end
81
82
  end
82
- rescue StandardError => e
83
+ rescue => e
83
84
  warn "failed processing message: #{e}\n#{e.backtrace}"
84
85
  end
85
86
 
@@ -123,41 +124,44 @@ class MQTTBridge
123
124
  end
124
125
 
125
126
  def publish_basic_attributes
126
- @homie_abc = @homie.node("abc", "Aurora Basic Control", "ABC") do |node|
127
+ @homie_abc = @homie.node("abc", "Heat Pump", "ABC") do |node|
127
128
  allowed_modes = %w[lockout standby blower heating cooling eh1 eh2 emergency waiting]
128
129
  allowed_modes << "dehumidify" if @abc.compressor.is_a?(Aurora::Compressor::VSDrive)
129
130
  node.property("current-mode", "Current Heating/Cooling Mode", :enum, @abc.current_mode,
130
131
  format: allowed_modes)
131
132
  node.property("entering-air-temperature", "Entering Air Temperature", :float, @abc.entering_air_temperature,
132
- unit: "ºF")
133
+ unit: "°F")
133
134
  node.property("entering-water-temperature", "Entering Water Temperature", :float,
134
- @abc.entering_water_temperature, unit: "ºF")
135
+ @abc.entering_water_temperature, unit: "°F")
135
136
  node.property("leaving-air-temperature", "Leaving Air Temperature", :float, @abc.leaving_air_temperature,
136
- unit: "ºF")
137
+ unit: "°F")
137
138
  node.property("leaving-water-temperature", "Leaving Water Temperature", :float, @abc.leaving_water_temperature,
138
- unit: "ºF")
139
+ unit: "°F")
139
140
  unless @abc.outdoor_temperature.zero? # TODO: figure out the config if this actually exists
140
- node.property("outdoor-temperature", "Outdoor Temperature", :float, @abc.outdoor_temperature, unit: "ºF")
141
+ node.property("outdoor-temperature", "Outdoor Temperature", :float, @abc.outdoor_temperature, unit: "°F")
141
142
  end
142
143
 
143
- node.property("fp1", "FP1 Sensor", :float, @abc.fp1, unit: "ºF")
144
- node.property("fp2", "FP2 Sensor", :float, @abc.fp2, unit: "ºF")
144
+ node.property("fp1", "FP1 Sensor", :float, @abc.fp1, unit: "°F")
145
+ node.property("fp2", "FP2 Sensor", :float, @abc.fp2, unit: "°F")
145
146
  %i[aux_heat total].each do |component|
146
147
  component = "#{component}_watts"
147
- node.property(component.tr("_", "-"), component.tr("_", " ").titleize, :integer,
148
- @abc.public_send(component), unit: "W")
148
+ node.property(component.tr("_", "-"),
149
+ component.sub("_watts", " Power Usage").tr("_", " ").titleize,
150
+ :integer,
151
+ @abc.public_send(component),
152
+ unit: "W")
149
153
  end
150
154
  end
151
155
 
152
156
  @compressor = @homie.node("compressor", "Compressor", @abc.compressor.type) do |node|
153
- node.property("speed", "Current compressor speed", :integer, @abc.compressor.speed,
157
+ node.property("speed", "Current Speed", :integer, @abc.compressor.speed,
154
158
  format: @abc.compressor.speed_range)
155
- node.property("watts", "Energy Usage", :integer, @abc.compressor.watts, unit: "W") if @abc.energy_monitoring?
159
+ node.property("watts", "Power Usage", :integer, @abc.compressor.watts, unit: "W") if @abc.energy_monitoring?
156
160
 
157
161
  next unless @abc.compressor.is_a?(Aurora::Compressor::VSDrive)
158
162
 
159
- node.property("ambient-temperature", "Compressor ambient temperature", :float,
160
- @abc.compressor.ambient_temperature, unit: "ºF")
163
+ node.property("ambient-temperature", "Ambient Temperature", :float,
164
+ @abc.compressor.ambient_temperature, unit: "°F")
161
165
 
162
166
  next unless @abc.iz2?
163
167
 
@@ -166,19 +170,19 @@ class MQTTBridge
166
170
  end
167
171
 
168
172
  @blower = @homie.node("blower", "Blower", @abc.blower.type) do |node|
169
- node.property("running", "Blower is running", :boolean, @abc.blower.running?)
173
+ node.property("running", "Running", :boolean, @abc.blower.running?)
170
174
  if @abc.blower.respond_to?(:speed)
171
- node.property("speed", "Current blower speed", :integer, @abc.blower.speed, format: @abc.blower.speed_range)
175
+ node.property("speed", "Current Speed", :integer, @abc.blower.speed, format: @abc.blower.speed_range)
172
176
  end
173
- node.property("watts", "Energy Usage", :integer, @abc.blower.watts, unit: "W") if @abc.energy_monitoring?
177
+ node.property("watts", "Power Usage", :integer, @abc.blower.watts, unit: "W") if @abc.energy_monitoring?
174
178
 
175
179
  next unless @abc.blower.is_a?(Aurora::Blower::ECM)
176
180
 
177
181
  presets = %w[blower-only aux-heat]
178
182
  presets.concat %w[low-compressor high-compressor] unless @abc.iz2?
179
183
  presets.each do |setting|
180
- field = "#{setting.tr('-', '_')}_speed"
181
- node.property("#{setting}-speed", "#{setting.tr('-', ' ').titleize} Preset Speed", :integer,
184
+ field = "#{setting.tr("-", "_")}_speed"
185
+ node.property("#{setting}-speed", "#{setting.tr("-", " ").titleize} Preset Speed", :integer,
182
186
  @abc.blower.public_send(field), format: 1..12) do |value, property|
183
187
  @mutex.synchronize { property.value = @abc.blower.public_send("#{field}=", value) }
184
188
  end
@@ -192,23 +196,23 @@ class MQTTBridge
192
196
 
193
197
  @pump = @homie.node("pump", "Loop Pump", @abc.pump.type) do |node|
194
198
  node.property("waterflow", "Waterflow", :float, @abc.pump.waterflow, unit: "gpm")
195
- node.property("watts", "Energy Usage", :integer, @abc.pump.watts, unit: "W") if @abc.energy_monitoring?
199
+ node.property("watts", "Power Usage", :integer, @abc.pump.watts, unit: "W") if @abc.energy_monitoring?
196
200
 
197
201
  next unless @abc.pump.is_a?(Aurora::Pump::VSPump)
198
202
 
199
- node.property("running", "Pump is running", :boolean, @abc.pump.running)
203
+ node.property("running", "Running", :boolean, @abc.pump.running)
200
204
  node.property("speed", "Speed", :integer, @abc.pump.speed, format: 0..100, unit: "%") do |value, property|
201
205
  @mutex.synchronize { property.value = @abc.pump.speed = value }
202
206
  end
203
- node.property("manual-control", "If manual control is enabled", :boolean,
207
+ node.property("manual-control", "Manual Control", :boolean,
204
208
  @abc.pump.manual_control?) do |value, property|
205
209
  @mutex.synchronize { property.value = @abc.pump.manual_control = value }
206
210
  end
207
- node.property("minimum-speed", "Speed pump runs at compressor speed 0", :integer, @abc.pump.minimum_speed,
211
+ node.property("minimum-speed", "Actual Minimum Speed", :integer, @abc.pump.minimum_speed,
208
212
  format: 0..100, unit: "%") do |value, property|
209
213
  @mutex.synchronize { property.value = @abc.pump.minimum_speed = value }
210
214
  end
211
- node.property("maximum-speed", "Speed pump runs at compressor speed 12", :integer, @abc.pump.minimum_speed,
215
+ node.property("maximum-speed", "Actual Maximum Speed", :integer, @abc.pump.minimum_speed,
212
216
  format: 0..100, unit: "%") do |value, property|
213
217
  @mutex.synchronize { property.value = @abc.pump.maximum_speed = value }
214
218
  end
@@ -219,11 +223,11 @@ class MQTTBridge
219
223
  node.property("enabled", "Enabled", :boolean, @abc.dhw.enabled) do |value, property|
220
224
  @mutex.synchronize { property.value = @abc.dhw.enabled = value }
221
225
  end
222
- node.property("running", "DHW Pump is running", :boolean, @abc.dhw.running?)
226
+ node.property("running", "Pump Running", :boolean, @abc.dhw.running?)
223
227
  node.property("water-temperature", "Water Temperature", :float,
224
- @abc.dhw.water_temperature, unit: "ºF")
228
+ @abc.dhw.water_temperature, unit: "°F")
225
229
  node.property("set-point", "Set Point", :float, @abc.dhw.set_point, format: 100..140,
226
- unit: "ºF") do |value, property|
230
+ unit: "°F") do |value, property|
227
231
  @mutex.synchronize { property.value = @abc.dhw.set_point = value }
228
232
  end
229
233
  end
@@ -233,12 +237,12 @@ class MQTTBridge
233
237
  node.property("relative-humidity", "Relative Humidity", :integer, @abc.humidistat.relative_humidity,
234
238
  unit: "%", format: 0..100)
235
239
  if @abc.humidistat.humidifier?
236
- node.property("humidifier-running", "Humidifier is running", :boolean, @abc.humidistat.humidifier_running?)
240
+ node.property("humidifier-running", "Humidifier Running", :boolean, @abc.humidistat.humidifier_running?)
237
241
  node.property("humidifier-mode", "Humidifier Mode", :enum, @abc.humidistat.humidifier_mode,
238
242
  format: %i[auto manual]) do |value, property|
239
243
  @mutex.synchronize { property.value = @abc.humidistat.humidifier_mode = value.to_sym }
240
244
  end
241
- node.property("humidification-target", "Humidification target relative humidity", :integer,
245
+ node.property("humidification-target", "Humidification Target Relative Humidity", :integer,
242
246
  @abc.humidistat.humidification_target, unit: "%", format: 15..50) do |value, property|
243
247
  @mutex.synchronize { property.value = @abc.humidistat.humidification_target = value }
244
248
  end
@@ -246,23 +250,20 @@ class MQTTBridge
246
250
 
247
251
  # VSDrive can perform active dehumidification, even without a dedicated dehumidifier
248
252
  if @abc.humidistat.dehumidifier? || @abc.compressor.is_a?(Aurora::Compressor::VSDrive)
253
+ node.property("dehumidifier-running", "Dehumidifier Running", :boolean, @abc.humidistat.dehumidifier_running?)
249
254
  node.property("dehumidifier-mode", "Dehumidifier Mode", :enum, @abc.humidistat.dehumidifier_mode,
250
255
  format: %i[auto manual]) do |value, property|
251
256
  @mutex.synchronize { property.value = @abc.humidistat.dehumidifier_mode = value.to_sym }
252
257
  end
253
- node.property("dehumidification-target", "Dehumidification target relative humidity", :integer,
258
+ node.property("dehumidification-target", "Dehumidification Target Relative Humidity", :integer,
254
259
  @abc.humidistat.dehumidification_target, unit: "%", format: 35..65) do |value, property|
255
260
  @mutex.synchronize { property.value = @abc.humidistat.dehumidification_target = value }
256
261
  end
257
262
  end
258
-
259
- next unless @abc.humidistat.dehumidifier?
260
-
261
- node.property("dehumidifier-running", "Dehumidifier is running", :boolean, @abc.humidistat.dehumidifier_running?)
262
263
  end
263
264
 
264
265
  @faults = @homie.node("faults", "Fault History", "ABC") do |node|
265
- node.property("clear-history", "Reset fault counts", :enum, retained: false, format: "clear") do |_|
266
+ node.property("clear-history", "Reset Fault Counts", :enum, retained: false, format: "clear") do |_|
266
267
  @mutex.synchronize { @abc.clear_fault_history }
267
268
  end
268
269
  @abc.faults.each_with_index do |count, i|
@@ -302,13 +303,13 @@ class MQTTBridge
302
303
  node.property("size", "Size", :enum, zone.size, format: %w[0 25 45 70])
303
304
  node.property("normalized-size", "Normalized Size", :integer, zone.normalized_size, unit: "%", format: 0..100)
304
305
  end
305
- node.property("ambient-temperature", "Ambient Temperature", :float, zone.ambient_temperature, unit: "ºF")
306
+ node.property("ambient-temperature", "Ambient Temperature", :float, zone.ambient_temperature, unit: "°F")
306
307
  node.property("heating-target-temperature", "Heating Target Temperature", :integer,
307
- zone.heating_target_temperature, unit: "ºF", format: 40..90) do |value, property|
308
+ zone.heating_target_temperature, unit: "°F", format: 40..90) do |value, property|
308
309
  @mutex.synchronize { property.value = zone.heating_target_temperature = value }
309
310
  end
310
311
  node.property("cooling-target-temperature", "Cooling Target Temperature", :integer,
311
- zone.cooling_target_temperature, unit: "ºF", format: 54..99) do |value, property|
312
+ zone.cooling_target_temperature, unit: "°F", format: 54..99) do |value, property|
312
313
  @mutex.synchronize { property.value = zone.cooling_target_temperature = value }
313
314
  end
314
315
  end
@@ -318,7 +319,169 @@ class MQTTBridge
318
319
  @homie.mqtt.subscribe("#{@homie.topic}/$modbus")
319
320
  @homie.mqtt.subscribe("#{@homie.topic}/$modbus/getregs")
320
321
  @homie.mqtt.subscribe("#{@homie.topic}/$modbus/+/set")
321
- @homie.publish
322
+ @homie.publish do
323
+ # do HASS publishes in this block so they're done in bulk
324
+
325
+ MQTT::HomeAssistant.publish_sensor(@homie["abc"]["current-mode"],
326
+ device_class: :power)
327
+ MQTT::HomeAssistant.publish_sensor(@homie["abc"]["entering-air-temperature"],
328
+ device_class: :temperature,
329
+ entity_category: :diagnostic)
330
+ MQTT::HomeAssistant.publish_sensor(@homie["abc"]["entering-water-temperature"],
331
+ device_class: :temperature,
332
+ entity_category: :diagnostic)
333
+ MQTT::HomeAssistant.publish_sensor(@homie["abc"]["leaving-air-temperature"],
334
+ device_class: :temperature,
335
+ entity_category: :diagnostic)
336
+ MQTT::HomeAssistant.publish_sensor(@homie["abc"]["leaving-water-temperature"],
337
+ device_class: :temperature,
338
+ entity_category: :diagnostic)
339
+ unless @abc.outdoor_temperature.zero?
340
+ MQTT::HomeAssistant.publish_sensor(@homie["abc"]["outdoor-temperature"],
341
+ device_class: :temperature)
342
+ end
343
+ MQTT::HomeAssistant.publish_sensor(@homie["abc"]["fp1"],
344
+ device_class: :temperature,
345
+ entity_category: :diagnostic)
346
+ MQTT::HomeAssistant.publish_sensor(@homie["abc"]["fp2"],
347
+ device_class: :temperature,
348
+ entity_category: :diagnostic)
349
+ MQTT::HomeAssistant.publish_sensor(@homie["abc"]["aux-heat-watts"],
350
+ device_class: :power)
351
+ MQTT::HomeAssistant.publish_sensor(@homie["abc"]["total-watts"],
352
+ device_class: :power)
353
+
354
+ MQTT::HomeAssistant.publish_sensor(@homie["compressor"]["speed"])
355
+ MQTT::HomeAssistant.publish_sensor(@homie["compressor"]["watts"],
356
+ device_class: :power)
357
+
358
+ if @abc.compressor.is_a?(Aurora::Compressor::VSDrive)
359
+ MQTT::HomeAssistant.publish_sensor(@homie["compressor"]["ambient-temperature"],
360
+ device_class: :temperature,
361
+ entity_category: :diagnostic)
362
+
363
+ if @abc.iz2?
364
+ MQTT::HomeAssistant.publish_sensor(@homie["compressor"]["iz2-desired-speed"],
365
+ entity_category: :diagnostic)
366
+ end
367
+ end
368
+
369
+ MQTT::HomeAssistant.publish_binary_sensor(@homie["blower"]["running"],
370
+ device_class: :running)
371
+ MQTT::HomeAssistant.publish_sensor(@homie["blower"]["speed"]) if @abc.blower.respond_to?(:speed)
372
+ MQTT::HomeAssistant.publish_sensor(@homie["blower"]["watts"],
373
+ device_class: :power)
374
+ MQTT::HomeAssistant.publish_number(@homie["blower"]["blower-only-speed"],
375
+ entity_category: :config)
376
+ MQTT::HomeAssistant.publish_number(@homie["blower"]["aux-heat-speed"],
377
+ entity_category: :config)
378
+ if @abc.iz2?
379
+ MQTT::HomeAssistant.publish_sensor(@homie["blower"]["iz2-desired-speed"])
380
+ else
381
+ MQTT::HomeAssistant.publish_number(@homie["blower"]["low-compressor-speed"],
382
+ entity_category: :config)
383
+ MQTT::HomeAssistant.publish_number(@homie["blower"]["high-compressor-speed"],
384
+ entity_category: :config)
385
+ end
386
+
387
+ MQTT::HomeAssistant.publish_sensor(@homie["pump"]["waterflow"],
388
+ entity_category: :diagnostic)
389
+ MQTT::HomeAssistant.publish_sensor(@homie["pump"]["watts"],
390
+ device_class: :power)
391
+
392
+ if @abc.pump.is_a?(Aurora::Pump::VSPump)
393
+ MQTT::HomeAssistant.publish_binary_sensor(@homie["pump"]["running"],
394
+ device_class: :running)
395
+ MQTT::HomeAssistant.publish_number(@homie["pump"]["speed"],
396
+ entity_category: :diagnostic)
397
+
398
+ MQTT::HomeAssistant.publish_switch(@homie["pump"]["manual-control"],
399
+ entity_category: :diagnostic)
400
+ MQTT::HomeAssistant.publish_number(@homie["pump"]["minimum-speed"],
401
+ entity_category: :config)
402
+ MQTT::HomeAssistant.publish_number(@homie["pump"]["maximum-speed"],
403
+ entity_category: :config)
404
+ end
405
+
406
+ MQTT::HomeAssistant.publish_scene(@homie["faults"]["clear-history"])
407
+ @homie["faults"].each do |property|
408
+ next if property.id == "clear-history"
409
+
410
+ MQTT::HomeAssistant.publish_sensor(property,
411
+ entity_category: :diagnostic)
412
+ end
413
+
414
+ if @abc.dhw
415
+ MQTT::HomeAssistant.publish_switch(@homie["dhw"]["enabled"],
416
+ icon: "mdi:water-boiler")
417
+ MQTT::HomeAssistant.publish_binary_sensor(@homie["dhw"]["running"],
418
+ device_class: :running)
419
+ MQTT::HomeAssistant.publish_sensor(@homie["dhw"]["water-temperature"],
420
+ device_class: :temperature)
421
+ MQTT::HomeAssistant.publish_number(@homie["dhw"]["set-point"])
422
+ end
423
+
424
+ MQTT::HomeAssistant.publish_sensor(@homie["humidistat"]["relative-humidity"],
425
+ device_class: :humidity)
426
+ if @abc.humidistat.humidifier?
427
+ MQTT::HomeAssistant.publish_humidifier(
428
+ @homie["humidistat"]["humidifier-running"],
429
+ device_class: :humidifier,
430
+ name: "Humidifier",
431
+ id: "humidifier",
432
+ target_property: @homie["humidistat"]["humidification-target"],
433
+ mode_property: @homie["humidistat"]["humidifier-mode"]
434
+ )
435
+ end
436
+ if @abc.humidistat.dehumidifier? || @abc.compressor.is_a?(Aurora::Compressor::VSDrive)
437
+ MQTT::HomeAssistant.publish_humidifier(
438
+ @homie["humidistat"]["dehumidifier-running"],
439
+ device_class: :dehumidifier,
440
+ name: "Dehumidifier",
441
+ id: "dehumidifier",
442
+ target_property: @homie["humidistat"]["dehumidification-target"],
443
+ mode_property: @homie["humidistat"]["dehumidifier-mode"]
444
+ )
445
+ end
446
+
447
+ @abc.zones.each_with_index do |zone, i|
448
+ homie_zone = @homie["zone#{i + 1}"]
449
+ MQTT::HomeAssistant.publish_climate(
450
+ action_property: homie_zone["current-mode"],
451
+ current_temperature_property: homie_zone["ambient-temperature"],
452
+ fan_mode_property: homie_zone["target-fan-mode"],
453
+ mode_property: homie_zone["target-mode"],
454
+ temperature_high_property: homie_zone["cooling-target-temperature"],
455
+ temperature_low_property: homie_zone["heating-target-temperature"],
456
+ templates: {
457
+ action_template: <<~JINJA
458
+ {% if value.startswith('h') %}
459
+ heating
460
+ {% elif value.startswith('c') %}
461
+ cooling
462
+ {% elif value == 'standby' %}
463
+ idle
464
+ {% endif %}
465
+ JINJA
466
+ }
467
+ )
468
+ MQTT::HomeAssistant.publish_binary_sensor(homie_zone["current-fan-mode"],
469
+ device_class: :running)
470
+ MQTT::HomeAssistant.publish_select(homie_zone["fan-intermittent-on"],
471
+ entity_category: :config)
472
+ MQTT::HomeAssistant.publish_select(homie_zone["fan-intermittent-off"],
473
+ entity_category: :config)
474
+
475
+ next unless zone.is_a?(Aurora::IZ2Zone)
476
+
477
+ MQTT::HomeAssistant.publish_sensor(homie_zone["priority"],
478
+ entity_category: :diagnostic)
479
+ MQTT::HomeAssistant.publish_sensor(homie_zone["size"],
480
+ entity_category: :diagnostic)
481
+ MQTT::HomeAssistant.publish_sensor(homie_zone["normalized-size"],
482
+ entity_category: :diagnostic)
483
+ end
484
+ end
322
485
  end
323
486
  end
324
487
 
@@ -328,7 +491,7 @@ logger.level = log_level
328
491
  abc.modbus_slave.logger = logger
329
492
 
330
493
  device = "aurora-#{abc.serial_number}"
331
- homie = MQTT::Homie::Device.new(device, "Aurora MQTT Bridge", mqtt: mqtt_uri)
494
+ homie = MQTT::Homie::Device.new(device, "WaterFurnace", mqtt: mqtt_uri)
332
495
  homie.logger = logger
333
496
 
334
497
  MQTTBridge.new(abc, homie)
data/exe/web_aid_tool CHANGED
@@ -120,3 +120,7 @@ get "/request.cgi" do
120
120
 
121
121
  encode_result(result)
122
122
  end
123
+
124
+ # can't rely on this running automatically when we're installed as a gem,
125
+ # because the wrapper script will confuse it
126
+ Sinatra::Application.run!
@@ -92,14 +92,14 @@ module Aurora
92
92
  when 3 then Blower::FiveSpeed.new(self, registers[404])
93
93
  else; Blower::PSC.new(self, registers[404])
94
94
  end
95
- @pump = if (3..5).include?(raw_registers[413])
95
+ @pump = if (3..5).cover?(raw_registers[413])
96
96
  Pump::VSPump.new(self,
97
97
  registers[413])
98
98
  else
99
99
  Pump::GenericPump.new(self,
100
100
  registers[413])
101
101
  end
102
- @dhw = DHW.new(self) if (-999..999).include?(registers[1114])
102
+ @dhw = DHW.new(self) if (-999..999).cover?(registers[1114])
103
103
  @humidistat = Humidistat.new(self,
104
104
  @abc_dipswitches[:accessory_relay] == :humidifier,
105
105
  @axb_dipswitches[:accessory_relay2] == :dehumidifier)
@@ -171,7 +171,7 @@ module Aurora
171
171
  @fp2 = registers[20]
172
172
  @locked_out = registers[25] & 0x8000
173
173
  @error = registers[25] & 0x7fff
174
- @derated = (41..46).include?(@error)
174
+ @derated = (41..46).cover?(@error)
175
175
  @safe_mode = [47, 48, 49, 72, 74].include?(@error)
176
176
  @aux_heat_watts = registers[1151]
177
177
  @total_watts = registers[1153]
@@ -212,7 +212,7 @@ module Aurora
212
212
  end
213
213
 
214
214
  def line_voltage=(value)
215
- raise ArgumentError unless (90..635).include?(value)
215
+ raise ArgumentError unless (90..635).cover?(value)
216
216
 
217
217
  @modbus_slave.holding_registers[112] = value
218
218
  end
@@ -227,13 +227,13 @@ module Aurora
227
227
  pump_speed: :with_compressor,
228
228
  aux_heat: false)
229
229
  raise ArgumentError, "mode must be :off, :heating, or :cooling" unless %i[off heating cooling].include?(mode)
230
- raise ArgumentError, "compressor speed must be between 0 and 12" unless (0..12).include?(compressor_speed)
230
+ raise ArgumentError, "compressor speed must be between 0 and 12" unless (0..12).cover?(compressor_speed)
231
231
 
232
- unless blower_speed == :with_compressor || (0..12).include?(blower_speed)
232
+ unless blower_speed == :with_compressor || (0..12).cover?(blower_speed)
233
233
  raise ArgumentError,
234
234
  "blower speed must be :with_compressor or between 0 and 12"
235
235
  end
236
- unless pump_speed == :with_compressor || (0..100).include?(pump_speed)
236
+ unless pump_speed == :with_compressor || (0..100).cover?(pump_speed)
237
237
  raise ArgumentError,
238
238
  "pump speed must be :with_compressor or between 0 and 100"
239
239
  end
@@ -273,7 +273,7 @@ module Aurora
273
273
  def inspect
274
274
  "#<Aurora::ABCClient #{(instance_variables - [:@modbus_slave]).map do |iv|
275
275
  "#{iv}=#{instance_variable_get(iv).inspect}"
276
- end.join(', ')}>"
276
+ end.join(", ")}>"
277
277
  end
278
278
  end
279
279
  end
data/lib/aurora/blower.rb CHANGED
@@ -6,7 +6,7 @@ module Aurora
6
6
  module Blower
7
7
  class PSC < Component
8
8
  attr_reader :type, :watts, :running
9
- alias running? running
9
+ alias_method :running?, :running
10
10
 
11
11
  def initialize(abc, type)
12
12
  super(abc)
@@ -9,7 +9,7 @@ module Aurora
9
9
  def inspect
10
10
  "#<Aurora::#{self.class.name} #{(instance_variables - [:@abc]).map do |iv|
11
11
  "#{iv}=#{instance_variable_get(iv).inspect}"
12
- end.join(', ')}>"
12
+ end.join(", ")}>"
13
13
  end
14
14
 
15
15
  private
@@ -13,7 +13,7 @@ module Aurora
13
13
  end
14
14
 
15
15
  def type
16
- "#{@stages == 2 ? 'Dual' : 'Single'} Stage Compressor"
16
+ "#{@stages == 2 ? "Dual" : "Single"} Stage Compressor"
17
17
  end
18
18
 
19
19
  def speed_range
data/lib/aurora/dhw.rb CHANGED
@@ -5,7 +5,7 @@ require "aurora/component"
5
5
  module Aurora
6
6
  class DHW < Component
7
7
  attr_reader :enabled, :running, :set_point, :water_temperature
8
- alias running? running
8
+ alias_method :running?, :running
9
9
 
10
10
  def registers_to_read
11
11
  [400..401, 1114]
@@ -23,7 +23,7 @@ module Aurora
23
23
  end
24
24
 
25
25
  def set_point=(value) # rubocop:disable Naming/AccessorMethodName
26
- raise ArgumentError unless (100..140).include?(value)
26
+ raise ArgumentError unless (100..140).cover?(value)
27
27
 
28
28
  raw_value = (value * 10).to_i
29
29
  holding_registers[401] = raw_value
@@ -5,10 +5,9 @@ require "aurora/component"
5
5
  module Aurora
6
6
  class Humidistat < Component
7
7
  attr_reader :humidifier_running, :humidifier_mode, :humidification_target,
8
- :dehumidifier_running, :dehumidifier_mode, :dehumidification_target,
8
+ :dehumidifier_mode, :dehumidification_target,
9
9
  :relative_humidity
10
- alias humidifier_running? humidifier_running
11
- alias dehumidifer_running? dehumidifier_running
10
+ alias_method :humidifier_running?, :humidifier_running
12
11
 
13
12
  def initialize(abc, has_humidifier, has_dehumidifier)
14
13
  super(abc)
@@ -24,6 +23,11 @@ module Aurora
24
23
  @dehumidifier
25
24
  end
26
25
 
26
+ def dehumidifier_running
27
+ dehumidifier? ? @dehumidifier_running : abc.current_mode == :dehumidify
28
+ end
29
+ alias_method :dehumidifier_running?, :dehumidifier_running
30
+
27
31
  def registers_to_read
28
32
  result = [741]
29
33
  if humidifier? || dehumidifier? || abc.compressor.is_a?(Compressor::VSDrive)
@@ -82,8 +86,8 @@ module Aurora
82
86
  end
83
87
 
84
88
  def set_humidistat_targets(humidification_target, dehumidification_target)
85
- raise ArgumentError unless (15..50).include?(humidification_target)
86
- raise ArgumentError unless (35..65).include?(dehumidification_target)
89
+ raise ArgumentError unless (15..50).cover?(humidification_target)
90
+ raise ArgumentError unless (35..65).cover?(dehumidification_target)
87
91
 
88
92
  holding_registers[abc.iz2? ? 21_115 : 12_310] = (humidification_target << 8) + dehumidification_target
89
93
  @humidification_target = humidification_target
@@ -15,18 +15,18 @@ module Aurora
15
15
  end
16
16
 
17
17
  def registers_to_read
18
- base1 = 21_203 + (zone_number - 1) * 9
19
- base2 = 31_007 + (zone_number - 1) * 3
20
- base3 = 31_200 + (zone_number - 1) * 3
18
+ base1 = 21_203 + ((zone_number - 1) * 9)
19
+ base2 = 31_007 + ((zone_number - 1) * 3)
20
+ base3 = 31_200 + ((zone_number - 1) * 3)
21
21
  [base1..(base1 + 1), base2..(base2 + 2), base3]
22
22
  end
23
23
 
24
24
  def refresh(registers)
25
- @ambient_temperature = registers[31_007 + (zone_number - 1) * 3]
25
+ @ambient_temperature = registers[31_007 + ((zone_number - 1) * 3)]
26
26
 
27
- config1 = registers[31_008 + (zone_number - 1) * 3]
28
- config2 = registers[31_009 + (zone_number - 1) * 3]
29
- config3 = registers[31_200 + (zone_number - 1) * 3]
27
+ config1 = registers[31_008 + ((zone_number - 1) * 3)]
28
+ config2 = registers[31_009 + ((zone_number - 1) * 3)]
29
+ config3 = registers[31_200 + ((zone_number - 1) * 3)]
30
30
 
31
31
  @target_fan_mode = config1[:fan]
32
32
  @fan_intermittent_on = config1[:on_time]
@@ -45,28 +45,28 @@ module Aurora
45
45
  def target_mode=(value)
46
46
  return unless (raw_value = Aurora::HEATING_MODE.invert[value])
47
47
 
48
- holding_registers[21_202 + (zone_number - 1) * 9] = raw_value
48
+ holding_registers[21_202 + ((zone_number - 1) * 9)] = raw_value
49
49
  @target_mode = value
50
50
  end
51
51
 
52
52
  def target_fan_mode=(value)
53
53
  return unless (raw_value = Aurora::FAN_MODE.invert[value])
54
54
 
55
- holding_registers[21_205 + (zone_number - 1) * 9] = raw_value
55
+ holding_registers[21_205 + ((zone_number - 1) * 9)] = raw_value
56
56
  @target_fan_mode = value
57
57
  end
58
58
 
59
59
  def fan_intermittent_on=(value)
60
60
  return unless value >= 0 && value <= 25 && (value % 5).zero?
61
61
 
62
- holding_registers[21_206 + (zone_number - 1) * 9] = value
62
+ holding_registers[21_206 + ((zone_number - 1) * 9)] = value
63
63
  @fan_intermittent_on = value
64
64
  end
65
65
 
66
66
  def fan_intermittent_off=(value)
67
67
  return unless value >= 0 && value <= 40 && (value % 5).zero?
68
68
 
69
- holding_registers[21_207 + (zone_number - 1) * 9] = value
69
+ holding_registers[21_207 + ((zone_number - 1) * 9)] = value
70
70
  @fan_intermittent_off = value
71
71
  end
72
72
 
@@ -74,7 +74,7 @@ module Aurora
74
74
  return unless value >= 40 && value <= 90
75
75
 
76
76
  raw_value = (value * 10).to_i
77
- holding_registers[21_203 + (zone_number - 1) * 9] = raw_value
77
+ holding_registers[21_203 + ((zone_number - 1) * 9)] = raw_value
78
78
  @heating_target_temperature = value
79
79
  end
80
80
 
@@ -82,7 +82,7 @@ module Aurora
82
82
  return unless value >= 54 && value <= 99
83
83
 
84
84
  raw_value = (value * 10).to_i
85
- holding_registers[21_204 + (zone_number - 1) * 9] = raw_value
85
+ holding_registers[21_204 + ((zone_number - 1) * 9)] = raw_value
86
86
  @cooling_target_temperature = value
87
87
  end
88
88
  end
@@ -44,6 +44,6 @@ module Aurora
44
44
  def write_holding_register(addr, value)
45
45
  @registers[addr] = value
46
46
  end
47
- alias []= write_holding_register
47
+ alias_method :[]=, :write_holding_register
48
48
  end
49
49
  end
@@ -4,14 +4,14 @@ module Aurora
4
4
  module ModBus
5
5
  module Slave
6
6
  def read_multiple_holding_registers(*ranges)
7
- values = if ranges.any? { |r| r.is_a?(Range) }
7
+ values = if ranges.any?(Range)
8
8
  addrs_and_lengths = ranges.map do |r|
9
9
  r = Array(r)
10
10
  [r.first, r.last - r.first + 1]
11
11
  end.flatten
12
- query("A#{addrs_and_lengths.pack('n*')}").unpack("n*")
12
+ query("A#{addrs_and_lengths.pack("n*")}").unpack("n*")
13
13
  else
14
- query("B#{ranges.pack('n*')}").unpack("n*")
14
+ query("B#{ranges.pack("n*")}").unpack("n*")
15
15
  end
16
16
  ranges.map { |r| Array(r) }.flatten.zip(values).to_h
17
17
  end
data/lib/aurora/pump.rb CHANGED
@@ -6,7 +6,7 @@ module Aurora
6
6
  module Pump
7
7
  class GenericPump < Component
8
8
  attr_reader :type, :watts, :waterflow, :running
9
- alias running? running
9
+ alias_method :running?, :running
10
10
 
11
11
  def initialize(abc, type)
12
12
  super(abc)
@@ -28,7 +28,7 @@ module Aurora
28
28
 
29
29
  class VSPump < GenericPump
30
30
  attr_reader :speed, :minimum_speed, :maximum_speed, :manual_control
31
- alias manual_control? manual_control
31
+ alias_method :manual_control?, :manual_control
32
32
 
33
33
  def registers_to_read
34
34
  super + [321..325]
@@ -108,7 +108,7 @@ module Aurora
108
108
  48 => "EEV OD Comm Error", # Com with EEV is interupted EEV has gone independent mode
109
109
  49 => "Cabinet Temperature Sensor", # Ambient Temperature (Tamb) is <-76 or > 212 F and out of range or invalid
110
110
  51 => "Discharge Temp Sensor", # Discharge Sensor (Sd) is > 280 F or invalid (-76 to 392 F)
111
- 52 => "Suction Presure Sensor", # Suction Pressure (P0) is invalid (0 to 232 psi)
111
+ 52 => "Suction Pressure Sensor", # Suction Pressure (P0) is invalid (0 to 232 psi)
112
112
  53 => "Condensing Pressure Sensor", # Low condensing pressure (PD) or invalid (0 to 870 psi) Retry 10x.
113
113
  54 => "Low Supply Voltage", # Supply Voltage is <180 V (190V to reset) or powered off/on too quickly (<30 sec.).
114
114
  55 => "Out of Envelope", # Comp Operating out of envelope (P0) more than 90 sec. Retry 10x.
@@ -550,7 +550,7 @@ module Aurora
550
550
  REGISTER_FORMATS = {
551
551
  "%ds" => [1, 6, 9, 15, 84, 85, 110],
552
552
  "%dV" => [16, 112, 3331, 3424, 3523],
553
- "%0.1fºF" => [19, 20, 401, 501, 502, 567, 740, 745, 746, 747, 900, 903,
553
+ "%0.1f°F" => [19, 20, 401, 501, 502, 567, 740, 745, 746, 747, 900, 903,
554
554
  1109, 1110, 1111, 1112, 1113, 1114, 1124, 1125, 1134, 1135, 1136,
555
555
  3325, 3326, 3327, 3330, 3522, 3903, 3905, 3906,
556
556
  12_619, 12_620,
@@ -587,9 +587,9 @@ module Aurora
587
587
 
588
588
  def zone_registers
589
589
  (1..6).map do |i|
590
- base1 = 21_202 + (i - 1) * 9
591
- base2 = 31_007 + (i - 1) * 3
592
- base3 = 31_200 + (i - 1) * 3
590
+ base1 = 21_202 + ((i - 1) * 9)
591
+ base2 = 31_007 + ((i - 1) * 3)
592
+ base3 = 31_200 + ((i - 1) * 3)
593
593
  {
594
594
  base1 => "Zone #{i} Heating Mode (write)",
595
595
  (base1 + 1) => "Zone #{i} Heating Setpoint (write)",
@@ -1,5 +1,5 @@
1
1
  # frozen_string_literal: true
2
2
 
3
3
  module Aurora
4
- VERSION = "0.6.2"
4
+ VERSION = "0.7.1"
5
5
  end
metadata CHANGED
@@ -1,14 +1,14 @@
1
1
  --- !ruby/object:Gem::Specification
2
2
  name: waterfurnace_aurora
3
3
  version: !ruby/object:Gem::Version
4
- version: 0.6.2
4
+ version: 0.7.1
5
5
  platform: ruby
6
6
  authors:
7
7
  - Cody Cutrer
8
8
  autorequire:
9
9
  bindir: exe
10
10
  cert_chain: []
11
- date: 2021-09-03 00:00:00.000000000 Z
11
+ date: 2021-12-09 00:00:00.000000000 Z
12
12
  dependencies:
13
13
  - !ruby/object:Gem::Dependency
14
14
  name: ccutrer-serialport
@@ -25,19 +25,25 @@ dependencies:
25
25
  - !ruby/object:Gem::Version
26
26
  version: 1.0.0
27
27
  - !ruby/object:Gem::Dependency
28
- name: homie-mqtt
28
+ name: mqtt-homeassistant
29
29
  requirement: !ruby/object:Gem::Requirement
30
30
  requirements:
31
31
  - - "~>"
32
32
  - !ruby/object:Gem::Version
33
- version: 1.4.4
33
+ version: '0'
34
+ - - ">="
35
+ - !ruby/object:Gem::Version
36
+ version: 0.0.2
34
37
  type: :runtime
35
38
  prerelease: false
36
39
  version_requirements: !ruby/object:Gem::Requirement
37
40
  requirements:
38
41
  - - "~>"
39
42
  - !ruby/object:Gem::Version
40
- version: 1.4.4
43
+ version: '0'
44
+ - - ">="
45
+ - !ruby/object:Gem::Version
46
+ version: 0.0.2
41
47
  - !ruby/object:Gem::Dependency
42
48
  name: net-telnet-rfc2217
43
49
  requirement: !ruby/object:Gem::Requirement
@@ -92,32 +98,59 @@ dependencies:
92
98
  requirements:
93
99
  - - "~>"
94
100
  - !ruby/object:Gem::Version
95
- version: '9.0'
101
+ version: '11.0'
96
102
  type: :development
97
103
  prerelease: false
98
104
  version_requirements: !ruby/object:Gem::Requirement
99
105
  requirements:
100
106
  - - "~>"
101
107
  - !ruby/object:Gem::Version
102
- version: '9.0'
108
+ version: '11.0'
103
109
  - !ruby/object:Gem::Dependency
104
110
  name: rubocop
105
111
  requirement: !ruby/object:Gem::Requirement
106
112
  requirements:
107
113
  - - "~>"
108
114
  - !ruby/object:Gem::Version
109
- version: '1.19'
115
+ version: '1.23'
116
+ type: :development
117
+ prerelease: false
118
+ version_requirements: !ruby/object:Gem::Requirement
119
+ requirements:
120
+ - - "~>"
121
+ - !ruby/object:Gem::Version
122
+ version: '1.23'
123
+ - !ruby/object:Gem::Dependency
124
+ name: rubocop-performance
125
+ requirement: !ruby/object:Gem::Requirement
126
+ requirements:
127
+ - - "~>"
128
+ - !ruby/object:Gem::Version
129
+ version: '1.12'
130
+ type: :development
131
+ prerelease: false
132
+ version_requirements: !ruby/object:Gem::Requirement
133
+ requirements:
134
+ - - "~>"
135
+ - !ruby/object:Gem::Version
136
+ version: '1.12'
137
+ - !ruby/object:Gem::Dependency
138
+ name: rubocop-rake
139
+ requirement: !ruby/object:Gem::Requirement
140
+ requirements:
141
+ - - "~>"
142
+ - !ruby/object:Gem::Version
143
+ version: '0.6'
110
144
  type: :development
111
145
  prerelease: false
112
146
  version_requirements: !ruby/object:Gem::Requirement
113
147
  requirements:
114
148
  - - "~>"
115
149
  - !ruby/object:Gem::Version
116
- version: '1.19'
150
+ version: '0.6'
117
151
  description:
118
152
  email: cody@cutrer.com'
119
153
  executables:
120
- - grab_awl_assets.sh
121
154
  - aurora_monitor
122
155
  - aurora_mqtt_bridge
123
156
  - web_aid_tool
@@ -130,7 +163,6 @@ files:
130
163
  - exe/aurora_mock
131
164
  - exe/aurora_monitor
132
165
  - exe/aurora_mqtt_bridge
133
- - exe/grab_awl_assets.sh
134
166
  - exe/web_aid_tool
135
167
  - lib/aurora.rb
136
168
  - lib/aurora/abc_client.rb
@@ -153,7 +185,8 @@ files:
153
185
  homepage: https://github.com/ccutrer/waterfurnace_aurora
154
186
  licenses:
155
187
  - MIT
156
- metadata: {}
188
+ metadata:
189
+ rubygems_mfa_required: 'true'
157
190
  post_install_message:
158
191
  rdoc_options: []
159
192
  require_paths:
@@ -1,21 +0,0 @@
1
- #!/bin/bash
2
-
3
- mkdir -p html
4
- mkdir -p html/css
5
- mkdir -p html/js
6
- mkdir -p html/images
7
-
8
- IP=${1:-172.20.10.1}
9
-
10
- curl http://$IP/ > html/index.htm
11
- curl http://$IP/config.htm > html/config.htm
12
- curl http://$IP/favicon.ico > html/favicon.ico
13
- curl http://$IP/css/index.css > html/css/index.css
14
- curl http://$IP/css/phone.css > html/css/phone.css
15
- curl http://$IP/js/indexc.js > html/js/indexc.js
16
- curl http://$IP/js/configc.js > html/js/configc.js
17
- curl http://$IP/images/aurora.png > html/images/aurora.png
18
- curl http://$IP/images/back.png > html/images/back.png
19
- curl http://$IP/images/cfailed.png > html/images/cfailed.png
20
- curl http://$IP/images/cgood.png > html/images/cgood.png
21
- curl http://$IP/images/cidle.png > html/images/cidle.png