waterfurnace_aurora 0.4.3 → 0.4.4
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +4 -4
- data/lib/aurora/abc_client.rb +0 -26
- data/lib/aurora/thermostat.rb +2 -2
- data/lib/aurora/version.rb +1 -1
- metadata +1 -1
checksums.yaml
CHANGED
@@ -1,7 +1,7 @@
|
|
1
1
|
---
|
2
2
|
SHA256:
|
3
|
-
metadata.gz:
|
4
|
-
data.tar.gz:
|
3
|
+
metadata.gz: c2fb8894c93d6a099f927e91a025fff0faf6a159b29808d089431640f60376b8
|
4
|
+
data.tar.gz: edb0f65d15fdb706aa7471a4f3df1247e8ba354d841b9ef35c1f6874b7376eb0
|
5
5
|
SHA512:
|
6
|
-
metadata.gz:
|
7
|
-
data.tar.gz:
|
6
|
+
metadata.gz: 2ed469c2b2cb39a166b8664e735579c7f8541eed4f9c3a2c5d7b22046321948925a8bdd2fe08bed455856cf5b36f113040bf9f8f18632f70cdbf9abca9078278
|
7
|
+
data.tar.gz: a01d310d261571b7e2d1aa9537c56072820de03708eb7b9188ccae9d303f5ab54d8c6832f5949667c274247d7ef59066af3c69bd58cc80352d55db27daafbbcc
|
data/lib/aurora/abc_client.rb
CHANGED
@@ -210,18 +210,6 @@ module Aurora
|
|
210
210
|
end
|
211
211
|
end
|
212
212
|
|
213
|
-
def blower_only_ecm_speed=(value)
|
214
|
-
return unless (1..12).include?(value)
|
215
|
-
|
216
|
-
@modbus_slave.holding_registers[340] = value
|
217
|
-
end
|
218
|
-
|
219
|
-
def aux_heat_ecm_speed=(value)
|
220
|
-
return unless (1..12).include?(value)
|
221
|
-
|
222
|
-
@modbus_slave.holding_registers[347] = value
|
223
|
-
end
|
224
|
-
|
225
213
|
def cooling_airflow_adjustment=(value)
|
226
214
|
value = 0x10000 + value if value.negative?
|
227
215
|
@modbus_slave.holding_registers[346] = value
|
@@ -241,20 +229,6 @@ module Aurora
|
|
241
229
|
@modbus_slave.holding_registers[419] = (value * 10).to_i
|
242
230
|
end
|
243
231
|
|
244
|
-
def vs_pump_control=(value)
|
245
|
-
raise ArgumentError unless (value = VS_PUMP_CONTROL.invert[value])
|
246
|
-
|
247
|
-
@modbus_slave.holding_registers[323] = value
|
248
|
-
end
|
249
|
-
|
250
|
-
def vs_pump_min=(value)
|
251
|
-
@modbus_slave.holding_registers[321] = value
|
252
|
-
end
|
253
|
-
|
254
|
-
def vs_pump_max=(value)
|
255
|
-
@modbus_slave.holding_registers[322] = value
|
256
|
-
end
|
257
|
-
|
258
232
|
def line_voltage=(value)
|
259
233
|
raise ArgumentError unless (90..635).include?(value)
|
260
234
|
|
data/lib/aurora/thermostat.rb
CHANGED
@@ -12,8 +12,8 @@ module Aurora
|
|
12
12
|
|
13
13
|
def refresh(registers)
|
14
14
|
@ambient_temperature = registers[502]
|
15
|
-
@heating_target_temperature = registers[
|
16
|
-
@cooling_target_temperature = registers[
|
15
|
+
@heating_target_temperature = registers[745]
|
16
|
+
@cooling_target_temperature = registers[746]
|
17
17
|
end
|
18
18
|
|
19
19
|
def target_mode=(value)
|
data/lib/aurora/version.rb
CHANGED