waterfurnace_aurora 0.3.10 → 0.4.0

Sign up to get free protection for your applications and to get access to all the features.
@@ -0,0 +1,48 @@
1
+ # frozen_string_literal: true
2
+
3
+ module Aurora
4
+ class MockABC
5
+ attr_accessor :logger
6
+
7
+ def initialize(registers)
8
+ @registers = registers
9
+ end
10
+
11
+ def read_retry_timeout=(_); end
12
+
13
+ def read_retries=(_); end
14
+
15
+ def holding_registers
16
+ self
17
+ end
18
+
19
+ def [](*register)
20
+ if register.length == 1
21
+ case register.first
22
+ when Integer
23
+ @registers[register.first]
24
+ when Range
25
+ @registers.values_at(*register.first.to_a)
26
+ else
27
+ raise ArgumentError, "Not implemented yet #{register.inspect}"
28
+ end
29
+ else
30
+ read_multiple_holding_registers(*register)
31
+ end
32
+ end
33
+
34
+ def read_multiple_holding_registers(*queries)
35
+ result = {}
36
+ queries.each do |query|
37
+ Array(query).each do |i|
38
+ result[i] = @registers[i]
39
+ end
40
+ end
41
+ result
42
+ end
43
+
44
+ def write_holding_register(addr, value)
45
+ @registers[addr] = value
46
+ end
47
+ end
48
+ end
@@ -59,69 +59,145 @@ module Aurora
59
59
  result
60
60
  end
61
61
 
62
+ def to_int32(registers, idx)
63
+ (registers[idx] << 16) + registers[idx + 1]
64
+ end
65
+
62
66
  def to_string(registers, idx, length)
63
67
  (idx...(idx + length)).map do |i|
68
+ raise ArgumentError, "Missing register #{i} for string starting at #{idx}" unless registers[i]
69
+
64
70
  (registers[i] >> 8).chr + (registers[i] & 0xff).chr
65
71
  end.join.sub(/[ \0]+$/, "")
66
72
  end
67
73
 
68
74
  FAULTS = {
69
- 1 => "Input Flt Limit",
70
- 2 => "High Pressure",
71
- 3 => "Low Pressure",
72
- 4 => "FP2",
73
- 5 => "FP1",
74
- 7 => "Condensate Limit",
75
- 8 => "Over/Under Voltage",
75
+ # ABC/AXB Basic Faults
76
+ 1 => "Input Error", # Tstat input error. Autoreset upon condition removal.
77
+ 2 => "High Pressure", # HP switch has tripped (>600 psi)
78
+ 3 => "Low Pressure", # Low Pressure Switch has tripped (<40 psi for 30 continous sec.)
79
+ 4 => "Freeze Detect FP2", # Freeze protection sensor has tripped (<15 or 30 degF for 30 continuous sec.)
80
+ 5 => "Freeze Detect FP1", # Freeze protection sensor has tripped (<15 or 30 degF for 30 continuous sec.)
81
+ 7 => "Condensate Overflow", # Condensate switch has shown continuity for 30 continuous sec.
82
+ 8 => "Over/Under Voltage", # Instantaneous Voltage is out of range. **Controls shut down until resolved.
76
83
  9 => "AirF/RPM",
77
- 10 => "CompMon",
78
- 11 => "FP1/2 Snr Limit",
79
- 12 => "RefPerfrm Limit",
80
- 13 => "NCrtAxbSr Limit",
81
- 14 => "CrtAxbSnr Limit",
82
- 15 => "HW Limit",
83
- 16 => "VSPumpFlt Limit",
84
- 17 => "CommTStat Limit",
85
- 18 => "NCritComm Limit",
86
- 19 => "Crit Comm Limit",
87
- 21 => "Low Loop Pressure",
88
- 22 => "ComEcmErr Limit",
89
- 23 => "HAGenAlrm1 Limit",
90
- 24 => "HAGenAlrm2 Limit",
91
- 25 => "AxbEevErr Limit",
92
- 41 => "High Drive Temp Limit",
93
- 42 => "High Discharge Temp Limit",
94
- 43 => "Low Suction Pressure Limit",
95
- 44 => "Low Con Pressure Limit",
96
- 45 => "High Con Pressure Limit",
97
- 46 => "Out Power Limit",
98
- 47 => "EevIDComm Limit",
99
- 48 => "EevODComm Limit",
100
- 49 => "CabTmpSnr Limit",
101
- 51 => "Discharge Temp Sensor Limit",
102
- 52 => "Suction Presure Sensor Limit",
103
- 53 => "Con Pressure Sensor Limit",
104
- 54 => "Low Supply Voltage Limit",
105
- 55 => "OutEnvelp Limit",
106
- 56 => "Suction Pressure Sensor Limit",
107
- 57 => "Drive Over/Under Voltage Limit",
108
- 58 => "High Drive Temp Limit",
109
- 59 => "Internal Drive Error Limit",
110
- 61 => "MultSafm",
111
- 71 => "ChrgLoss",
112
- 72 => "Suction Temp Sensor Limit",
113
- 73 => "Leaving Air Temp Sensor Limit",
114
- 74 => "Maximum Operating Pressure Limit",
115
- 75 => "Charge Loss",
116
- 76 => "Suction Temperatur Sensor Limit",
117
- 77 => "Leaving Air Temperature Sensor Limit",
118
- 78 => "Maximum Operating Pressure Limit"
84
+ 10 => "Compressor Monitor", # Open Crkt, Run, Start or welded cont
85
+ 11 => "FP1/2 Sensor Error",
86
+ 12 => "RefPerfrm Error",
87
+ # Miscellaneous
88
+ 13 => "Non-Critical AXB Sensor Error", # Any Other Sensor Error
89
+ 14 => "Critical AXB Sensor Error", # Sensor Err for EEV or HW
90
+ 15 => "Hot Water Limit", # HW over limit or logic lockout. HW pump deactivated.
91
+ 16 => "VS Pump Error", # Alert is read from PWM feedback.
92
+ 17 => "Communicating Thermostat Error",
93
+ 18 => "Non-Critical Communications Error", # Any non-critical com error
94
+ 19 => "Critical Communications Error", # Any critical com error. Auto reset upon condition removal
95
+ 21 => "Low Loop Pressure", # Loop pressure is below 3 psi for more than 3 minutes
96
+ 22 => "Communicating ECM Error",
97
+ 23 => "HA Alarm 1", # Closed contact input is present on Dig 2 input - Text is configurable.
98
+ 24 => "HA Alarm 2", # Closed contact input is present on Dig 3 input - Text is configurable.
99
+ 25 => "AxbEev Error",
100
+ # VS Drive
101
+ 41 => "High Drive Temp", # Drive Temp has reached critical High Temp (>239 ̊F/115 ̊C)
102
+ 42 => "High Discharge Temp", # Discharge temperature has reached critical high temp (> 280 ̊F/138 ̊C)
103
+ 43 => "Low Suction Pressure", # Suction Pressure is critically low (< 28 psig)
104
+ 44 => "Low Condensing Pressure", # Condensing pressure is critically low (< 119 psig)
105
+ 45 => "High Condensing Pressure", # Condensing pressure is critically high (> 654 psig)
106
+ 46 => "Output Power Limit", # Supply Voltage is <208V or Max Pwr is reached due to high pressure
107
+ 47 => "EEV ID Comm Error", # Com with EEV is interupted EEV has gone independent mode
108
+ 48 => "EEV OD Comm Error", # Com with EEV is interupted EEV has gone independent mode
109
+ 49 => "Cabinet Temperature Sensor", # Ambient Temperature (Tamb) is <-76 or > 212 F and out of range or invalid
110
+ 51 => "Discharge Temp Sensor", # Discharge Sensor (Sd) is > 280 F or invalid (-76 to 392 F)
111
+ 52 => "Suction Presure Sensor", # Suction Pressure (P0) is invalid (0 to 232 psi)
112
+ 53 => "Condensing Pressure Sensor", # Low condensing pressure (PD) or invalid (0 to 870 psi) Retry 10x.
113
+ 54 => "Low Supply Voltage", # Supply Voltage is <180 V (190V to reset) or powered off/on too quickly (<30 sec.).
114
+ 55 => "Out of Envelope", # Comp Operating out of envelope (P0) more than 90 sec. Retry 10x.
115
+ 56 => "Drive Over Currnet", # Over current tripped by phase loss, earth fault, short circuit, low water flow, low air flow, or major drive fault. # rubocop:disable Layout/LineLength
116
+ 57 => "Drive Over/Under Voltage", # DC Link Voltage to compressor is >450vdc or at minimum voltage (<185vdc).
117
+ 58 => "High Drive Temp", # Drive Temp has reached critical High Temp >239 F
118
+ 59 => "Internal Drive Error", # The MOC has encountered an internal fault or an internal error. Probably fatal.
119
+ 61 => "Multiple Safe Mode", # More than one SafeMode condition is present requiring lockout
120
+ # EEV2
121
+ 71 => "Loss of Charge", # High superheat and high EEV opening % for a long time will trigger a loss of charge fault
122
+ 72 => "Suction Temperature Sensor", # Suction Temperature Sensor is invalid (-76 to 392 F)
123
+ 73 => "Leaving Air Temperature Sensor", # Leaving Air Temperature Sensor is invalid (-76 to 392 F)
124
+ 74 => "Maximum Operating Pressure", # Suction pressure has exceeded that maximum operating level for 90 sec.
125
+ 99 => "System Reset"
126
+ }.freeze
127
+
128
+ SMARTGRID_ACTION = {
129
+ 0 => :none,
130
+ 1 => :unoccupied_set_points,
131
+ 2 => :load_shed,
132
+ 3 => :capacity_limiting,
133
+ 4 => :off_time
134
+ }.freeze
135
+
136
+ HA_ALARM = {
137
+ 0 => :none,
138
+ 1 => :general,
139
+ 2 => :security,
140
+ 3 => :sump,
141
+ 4 => :carbon_monoxide,
142
+ 5 => :dirty_filter
143
+ }.freeze
144
+
145
+ BRINE_TYPE = Hash.new("Water").merge!(
146
+ 485 => "Antifreeze"
147
+ ).freeze
148
+
149
+ FLOW_METER_TYPE = Hash.new("Other").merge!(
150
+ 0 => "None",
151
+ 1 => '3/4"',
152
+ 2 => '1"'
153
+ ).freeze
154
+
155
+ PUMP_TYPE = Hash.new("Other").merge!(
156
+ 0 => "Open Loop",
157
+ 1 => "FC1",
158
+ 2 => "FC2",
159
+ 3 => "VS Pump",
160
+ 4 => "VS Pump + 26-99",
161
+ 5 => "VS Pump + UPS26-99",
162
+ 6 => "FC1_GLNP",
163
+ 7 => "FC2_GLNP"
164
+ ).freeze
165
+
166
+ PHASE_TYPE = Hash.new("Other").merge!(
167
+ 0 => "Single",
168
+ 1 => "Three"
169
+ ).freeze
170
+
171
+ BLOWER_TYPE = Hash.new("Other").merge!(
172
+ 0 => "PSC",
173
+ 1 => "ECM 208/230",
174
+ 2 => "ECM 265/277",
175
+ 3 => "5 Speed ECM 460"
176
+ ).freeze
177
+
178
+ ENERGY_MONITOR_TYPE = Hash.new("Other").merge!(
179
+ 0 => "None",
180
+ 1 => "Compressor Monitor",
181
+ 2 => "Energy Monitor"
182
+ ).freeze
183
+
184
+ VS_FAULTS = {
185
+ "Under-Voltage Warning" => (71..77),
186
+ "RPM Sensor Signal Fault" => (78..82),
187
+ "Under-Voltage Stop" => (83..87),
188
+ "Rotor Locked" => (88..92),
189
+ "Standby" => (93..)
119
190
  }.freeze
120
191
 
192
+ def vs_fault(value)
193
+ name = VS_FAULTS.find { |(_, range)| range.include?(value) }&.first
194
+ name ? "#{value} #{name}" : value.to_s
195
+ end
196
+
121
197
  AR_SETTINGS = {
122
198
  0 => "Cycle with Compressor",
123
- 1 => "Cycle with Thermostat Humidification Call",
124
- 2 => "Slow Opening Water Valve",
199
+ 1 => "Slow Opening Water Valve",
200
+ 2 => "Cycle with Thermostat Humidification Call",
125
201
  3 => "Cycle with Blower"
126
202
  }.freeze
127
203
 
@@ -132,13 +208,20 @@ module Aurora
132
208
  fp1: value & 0x01 == 0x01 ? "30ºF" : "15ºF",
133
209
  fp2: value & 0x02 == 0x02 ? "30ºF" : "15ºF",
134
210
  rv: value & 0x04 == 0x04 ? "O" : "B",
135
- ar: AR_SETTINGS[(value >> 3) & 0x7],
211
+ ar: AR_SETTINGS[(value >> 3) & 0x3],
136
212
  cc: value & 0x20 == 0x20 ? "Single Stage" : "Dual Stage",
137
213
  lo: value & 0x40 == 0x40 ? "Continouous" : "Pulse",
138
- dh_rh: value & 0x80 == 0x80 ? "Dehumdifier On" : "Reheat On"
214
+ dh_rh: value & 0x80 == 0x80 ? "Dehumidifier On" : "Reheat On"
139
215
  }
140
216
  end
141
217
 
218
+ COMPONENT_STATUS = {
219
+ 1 => :active,
220
+ 2 => :added,
221
+ 3 => :removed,
222
+ 0xffff => :missing
223
+ }.freeze
224
+
142
225
  SYSTEM_OUTPUTS = {
143
226
  0x01 => :cc, # compressor stage 1
144
227
  0x02 => :cc2, # compressor stage 2
@@ -151,15 +234,22 @@ module Aurora
151
234
  0x800 => :alarm
152
235
  }.freeze
153
236
 
237
+ # 5-speed ECM shows
238
+ # Aux if eh1 is on
239
+ # High if cc2 is on
240
+ # Med if cc1 is on
241
+ # Low if blower is on
242
+ # Off
243
+
154
244
  SYSTEM_INPUTS = {
155
- 0x01 => "Y1",
156
- 0x02 => "Y2",
157
- 0x04 => "W",
158
- 0x08 => "O",
159
- 0x10 => "G",
160
- 0x20 => "Dehumidifer",
161
- 0x40 => "Emergency Shutdown",
162
- 0x200 => "Load Shed"
245
+ 0x01 => :y1,
246
+ 0x02 => :y2,
247
+ 0x04 => :w,
248
+ 0x08 => :o,
249
+ 0x10 => :g,
250
+ 0x20 => :dh_rh,
251
+ 0x40 => :emergency_shutdown,
252
+ 0x200 => :load_shed
163
253
  }.freeze
164
254
 
165
255
  def status(value)
@@ -167,9 +257,10 @@ module Aurora
167
257
  lps: value & 0x80 == 0x80 ? :closed : :open,
168
258
  hps: value & 0x100 == 0x100 ? :closed : :open
169
259
  }
170
- result[:load_shed] = true if value & 0x0200 == 0x0200
171
- result[:emergency_shutdown] = true if value & 0x0040 == 0x0040
172
- leftover = value & ~0x03c0
260
+ SYSTEM_INPUTS.each do |(i, name)|
261
+ result[name] = true if value & i == i
262
+ end
263
+ leftover = value & ~0x03ff
173
264
  result[:unknown] = format("0x%04x", leftover) unless leftover.zero?
174
265
  result
175
266
  end
@@ -216,13 +307,36 @@ module Aurora
216
307
 
217
308
  }.freeze
218
309
 
219
- AXB_INPUTS = {
220
- }.freeze
310
+ def axb_inputs(value)
311
+ result = {}
312
+ result["Smart Grid"] = value & 0x001 == 0x001
313
+ result["Home Automation 1"] = value & 0x002 == 0x002
314
+ result["Home Automation 2"] = value & 0x004 == 0x004
315
+ result["Pump Slave"] = value & 0x008 == 0x008
316
+
317
+ result[:mb_address] = value & 0x010 == 0x010 ? 3 : 4
318
+ result[:sw1_2] = value & 0x020 == 0x020 # future use # rubocop:disable Naming/VariableNumber
319
+ result[:sw1_3] = value & 0x040 == 0x040 # future use # rubocop:disable Naming/VariableNumber
320
+ result[:cycle_with] = if value & 0x080 == 0x080 && value & 0x100 == 0x100
321
+ "Blower"
322
+ elsif value & 0x100 == 0x100
323
+ "Low Capacity Compressor"
324
+ elsif value & 0x080 == 0x080
325
+ "High Capacity Compressor"
326
+ else
327
+ "Thermostat Dehumidifier"
328
+ end
329
+ leftover = value & ~0x1ff
330
+ result[:unknown] = format("0x%04x", leftover) unless leftover.zero?
331
+ result
332
+ end
221
333
 
222
334
  AXB_OUTPUTS = {
223
- 0x10 => "Accessory 2",
224
- 0x02 => "Loop Pump",
225
- 0x01 => "DHW"
335
+ 0x01 => :dhw,
336
+ 0x02 => :loop_pump,
337
+ 0x04 => :diverting_valve,
338
+ 0x08 => :dehumidifer_reheat,
339
+ 0x10 => :accessory2
226
340
  }.freeze
227
341
 
228
342
  HEATING_MODE = {
@@ -267,6 +381,33 @@ module Aurora
267
381
  0x7 => :unknown7
268
382
  }.freeze
269
383
 
384
+ def manual_operation(value)
385
+ return :off if value == 0x7fff
386
+
387
+ result = {
388
+ mode: value & 0x100 == 0x100 ? :cooling : :heating
389
+ }
390
+ result[:aux_heat] = true if value & 0x200 == 0x200
391
+ result[:compressor_speed] = value & 0xf
392
+ result[:blower_speed] = value & 0xf0
393
+ result[:blower_speed] = :with_compressor if value & 0xf0 == 0xf0
394
+ leftover = value & ~0x03ff
395
+ result[:unknown] = format("0x%04x", leftover) unless leftover.zero?
396
+ result
397
+ end
398
+
399
+ def vs_manual_control(value)
400
+ return :off if value == 0x7fff
401
+
402
+ value
403
+ end
404
+
405
+ def thermostat_override(value)
406
+ return [:off] if value == 0x7fff
407
+
408
+ from_bitmask(value, SYSTEM_INPUTS)
409
+ end
410
+
270
411
  def iz2_demand(value)
271
412
  {
272
413
  fan_demand: value >> 8,
@@ -274,6 +415,18 @@ module Aurora
274
415
  }
275
416
  end
276
417
 
418
+ def iz2_fan_desired(value)
419
+ case value
420
+ when 1 then 25
421
+ when 2 then 40
422
+ when 3 then 55
423
+ when 4 then 70
424
+ when 5 then 85
425
+ when 6 then 100
426
+ else value
427
+ end
428
+ end
429
+
277
430
  def zone_configuration1(value)
278
431
  fan = if value & 0x80 == 0x80
279
432
  :continuous
@@ -328,9 +481,11 @@ module Aurora
328
481
  # intermittent off time allowed: 5, 10, 15, 20, 25, 30, 35, 40
329
482
 
330
483
  REGISTER_CONVERTERS = {
331
- TO_HUNDREDTHS => [2, 3, 807, 813, 816, 817, 819, 820, 825, 828],
484
+ TO_HUNDREDTHS => [2, 3, 417, 418, 801, 804, 807, 813, 816, 817, 819, 820, 825, 828],
332
485
  method(:dipswitch_settings) => [4, 33],
333
- TO_TENTHS => [19, 20, 401, 567, 740, 745, 746, 747, 900, 1105, 1106, 1107, 1108, 1110, 1111, 1114, 1117, 1134, 1136,
486
+ TO_TENTHS => [19, 20, 401, 419, 501, 502, 567, 740, 745, 746, 747, 900,
487
+ 1105, 1106, 1107, 1108, 1109, 1110, 1111, 1112, 1113, 1114, 1115, 1116, 1117, 1119, 1124, 1125, 1134,
488
+ 3322, 3323, 3325, 3326, 3327, 3330, 3522, 3903, 3905, 3906,
334
489
  12_619, 12_620,
335
490
  21_203, 21_204,
336
491
  21_212, 21_213,
@@ -344,18 +499,35 @@ module Aurora
344
499
  ->(v) { from_bitmask(v, SYSTEM_OUTPUTS) } => [27, 30],
345
500
  ->(v) { from_bitmask(v, SYSTEM_INPUTS) } => [28],
346
501
  method(:status) => [31],
502
+ method(:thermostat_override) => [32],
503
+ ->(v) { !v.zero? } => [45, 362, 400],
347
504
  ->(registers, idx) { to_string(registers, idx, 4) } => [88],
348
505
  ->(registers, idx) { to_string(registers, idx, 12) } => [92],
349
506
  ->(registers, idx) { to_string(registers, idx, 5) } => [105],
350
- ->(v) { from_bitmask(v, VS_DRIVE_DERATE) } => [214],
351
- ->(v) { from_bitmask(v, VS_SAFE_MODE) } => [216],
352
- ->(v) { from_bitmask(v, VS_ALARM1) } => [217],
353
- ->(v) { from_bitmask(v, VS_ALARM2) } => [218],
354
- ->(v) { from_bitmask(v, VS_EEV2) } => [280],
507
+ ->(v) { from_bitmask(v, VS_DRIVE_DERATE) } => [214, 3223],
508
+ ->(v) { from_bitmask(v, VS_SAFE_MODE) } => [216, 3225],
509
+ ->(v) { from_bitmask(v, VS_ALARM1) } => [217, 3226],
510
+ ->(v) { from_bitmask(v, VS_ALARM2) } => [218, 3227],
511
+ ->(v) { from_bitmask(v, VS_EEV2) } => [280, 3804],
512
+ method(:vs_manual_control) => [323],
355
513
  NEGATABLE => [346, 1146],
356
- ->(v) { from_bitmask(v, AXB_INPUTS) } => [1103],
514
+ ->(v) { BRINE_TYPE[v] } => [402],
515
+ ->(v) { FLOW_METER_TYPE[v] } => [403],
516
+ ->(v) { BLOWER_TYPE[v] } => [404],
517
+ ->(v) { v.zero? ? :closed : :open } => [405, 408, 410],
518
+ ->(v) { SMARTGRID_ACTION[v] } => [406],
519
+ ->(v) { HA_ALARM[v] } => [409, 411],
520
+ ->(v) { ENERGY_MONITOR_TYPE[v] } => [412],
521
+ ->(v) { PUMP_TYPE[v] } => [413],
522
+ ->(v) { PHASE_TYPE[v] } => [416],
523
+ method(:iz2_fan_desired) => [565],
524
+ ->(registers, idx) { to_string(registers, idx, 8) } => [710],
525
+ ->(v) { COMPONENT_STATUS[v] } => [800, 803, 806, 812, 815, 818, 824, 827],
526
+ method(:axb_inputs) => [1103],
357
527
  ->(v) { from_bitmask(v, AXB_OUTPUTS) } => [1104],
358
- ->(v) { TO_TENTHS.call(NEGATABLE.call(v)) } => [1136],
528
+ ->(v) { TO_TENTHS.call(NEGATABLE.call(v)) } => [1135, 1136],
529
+ method(:to_int32) => [1146, 1148, 1150, 1152, 1154, 1156, 1164, 3422, 3424],
530
+ method(:manual_operation) => [3002],
359
531
  ->(v) { HEATING_MODE[v] } => [12_606, 21_202, 21_211, 21_220, 21_229, 21_238, 21_247],
360
532
  ->(v) { FAN_MODE[v] } => [12_621, 21_205, 21_214, 21_223, 21_232, 21_241, 21_250],
361
533
  ->(v) { from_bitmask(v, HUMIDIFIER_SETTINGS) } => [31_109],
@@ -373,9 +545,11 @@ module Aurora
373
545
  }.freeze
374
546
 
375
547
  REGISTER_FORMATS = {
376
- "%ds" => [1, 6, 9, 15, 84, 85],
377
- "%dV" => [16, 112],
378
- "%0.1fºF" => [19, 20, 401, 567, 740, 745, 746, 747, 900, 1110, 1111, 1114, 1134, 1136,
548
+ "%ds" => [1, 6, 9, 15, 84, 85, 110],
549
+ "%dV" => [16, 112, 3331, 3424, 3523],
550
+ "%0.1fºF" => [19, 20, 401, 501, 502, 567, 740, 745, 746, 747, 900,
551
+ 1109, 1110, 1111, 1112, 1113, 1114, 1124, 1125, 1134, 1135, 1136,
552
+ 3325, 3326, 3327, 3330, 3522, 3903, 3905, 3906,
379
553
  12_619, 12_620,
380
554
  21_203, 21_204,
381
555
  21_212, 21_213,
@@ -386,14 +560,17 @@ module Aurora
386
560
  31_003,
387
561
  31_007, 31_010, 31_013, 31_016, 31_019, 31_022],
388
562
  "E%d" => [25, 26],
389
- "%d%%" => [282, 321, 322, 346, 565, 741],
563
+ "%d%%" => [282, 321, 322, 325, 346, 565, 741, 1126, 3332, 3524, 3808],
564
+ "%0.1f psi" => [419, 1115, 1116, 1119, 3322, 3323],
390
565
  "%0.1fA" => [1105, 1106, 1107, 1108],
391
566
  "%0.1fgpm" => [1117],
392
- "%dW" => [1147, 1149, 1151, 1153, 1165],
393
- "%dBtuh" => [1157]
567
+ "%dW" => [1146, 1148, 1150, 1152, 1164, 3422],
568
+ "%dBtuh" => [1154, 1156]
394
569
  }.freeze
395
570
 
396
- def ignore(range)
571
+ def ignore(*range)
572
+ range = range.first if range.length == 1
573
+ range = [range] if range.is_a?(Integer)
397
574
  range.zip(Array.new(range.count)).to_h
398
575
  end
399
576
 
@@ -513,25 +690,32 @@ module Aurora
513
690
  ].freeze
514
691
 
515
692
  REGISTER_NAMES = {
693
+ 0 => "Test Mode Flag", # 0x100 for enabled; this might have other flags
516
694
  1 => "Random Start Delay",
517
695
  2 => "ABC Program Version",
518
696
  3 => "??? Version?",
519
697
  4 => "DIP Switch Override",
520
698
  6 => "Compressor Anti-Short Cycle Delay",
521
- 8 => "Unit Type?",
699
+ 8 => "ABC Program Revision",
522
700
  9 => "Compressor Minimum Run Time",
523
701
  15 => "Blower Off Delay",
524
702
  16 => "Line Voltage",
525
- 19 => "FP1",
703
+ 17 => "Aux/E Heat Stage", # this has some complicated condition based on
704
+ # current inputs and outputs on if it should have a value (310 - v) or (130 - v), or be 0
705
+ 19 => "FP1 (Cooling Liquid Line) Temperature",
526
706
  20 => "FP2",
527
707
  21 => "Condensate", # >= 270 normal, otherwise fault
528
- 25 => "Last Fault Number",
708
+ 25 => "Last Fault Number", # high bit set if locked out
529
709
  26 => "Last Lockout",
530
710
  27 => "System Outputs (At Last Lockout)",
531
711
  28 => "System Inputs (At Last Lockout)",
532
712
  30 => "System Outputs",
533
713
  31 => "Status",
714
+ 32 => "Thermostat Input Override",
534
715
  33 => "DIP Switch Status",
716
+ 36 => "ABC Board Rev",
717
+ 45 => "Test Mode (write)", # 1 to enable
718
+ 47 => "Clear Fault History", # 0x5555 to clear
535
719
  50 => "ECM Speed Low (== 5)",
536
720
  51 => "ECM Speed Med (== 5)",
537
721
  52 => "ECM Speed High (== 5)",
@@ -541,7 +725,8 @@ module Aurora
541
725
  88 => "ABC Program",
542
726
  92 => "Model Number",
543
727
  105 => "Serial Number",
544
- 112 => "Setup Line Voltage",
728
+ 110 => "Reheat Delay",
729
+ 112 => "Line Voltage Setting",
545
730
  201 => "Discharge Pressure", # I can't figure out how this number is represented;
546
731
  203 => "Suction Pressure",
547
732
  205 => "Discharge Temperature",
@@ -562,6 +747,9 @@ module Aurora
562
747
  284 => "Saturated Suction Temperature", ## ?? data format
563
748
  321 => "VS Pump Min",
564
749
  322 => "VS Pump Max",
750
+ 323 => "VS Pump Speed Manual Control",
751
+ 325 => "VS Pump Output",
752
+ 326 => "VS Pump Fault",
565
753
  340 => "Blower Only Speed",
566
754
  341 => "Lo Compressor ECM Speed",
567
755
  342 => "Hi Compressor ECM Speed",
@@ -569,25 +757,67 @@ module Aurora
569
757
  346 => "Cooling Airflow Adjustment",
570
758
  347 => "Aux Heat ECM Speed",
571
759
  362 => "Active Dehumidify", # any value is true
760
+ 400 => "DHW Enabled",
572
761
  401 => "DHW Setpoint",
573
- 414 => "On Peak/SmartGrid 2", # 0x0001 only
762
+ 402 => "Brine Type",
763
+ 403 => "Flow Meter Type",
764
+ 404 => "Blower Type",
765
+ 405 => "SmartGrid Trigger",
766
+ 406 => "SmartGrid Action", # 0/1 for 1/2; see 414
767
+ 407 => "Off Time Length",
768
+ 408 => "HA Alarm 1 Trigger",
769
+ 409 => "HA Alarm 1 Action",
770
+ 410 => "HA Alarm 2 Trigger",
771
+ 411 => "HA Alarm 2 Action",
772
+ 412 => "Energy Monitor", # 0 none, 1 compressor monitor, 2 energy monitor
773
+ 413 => "Pump Type",
774
+ 414 => "On Peak/SmartGrid", # 0x0001 only
775
+ 416 => "Energy Phase Type",
776
+ 417 => "Power Adjustment Factor L",
777
+ 418 => "Power Adjustment Factor H",
778
+ 419 => "Loop Pressure Trip",
779
+ 460 => "IZ2 Heartbeat?",
780
+ 461 => "IZ2 Heartbeat?",
781
+ 462 => "IZ2 Status", # 5 when online; 1 when in setup mode
574
782
  483 => "Number of IZ2 Zones",
783
+ 501 => "Set Point", # only read by AID tool? this is _not_ heating/cooling set point
784
+ 502 => "Ambient Temperature",
575
785
  564 => "IZ2 Compressor Speed Desired",
576
786
  565 => "IZ2 Blower % Desired",
577
787
  567 => "Entering Air",
788
+ 710 => "Fault Description",
578
789
  740 => "Entering Air",
579
790
  741 => "Relative Humidity",
580
791
  745 => "Heating Set Point",
581
792
  746 => "Cooling Set Point",
582
- 747 => "Ambient Temperature",
793
+ 747 => "Ambient Temperature", # from communicating thermostat? but set to 0 when mode is off?
794
+ 800 => "Thermostat Installed",
795
+ 801 => "Thermostat Version",
796
+ 802 => "Thermostat Revision",
797
+ 803 => "??? Installed",
798
+ 804 => "??? Version",
799
+ 805 => "??? Revision",
800
+ 806 => "AXB Installed",
583
801
  807 => "AXB Version",
802
+ 808 => "AXB Revision",
803
+ 809 => "AHB Installed",
804
+ 810 => "AHB Version",
805
+ 811 => "AHB Revision",
806
+ 812 => "IZ2 Installed",
584
807
  813 => "IZ2 Version",
585
- 816 => "AOC Version 1?",
586
- 817 => "AOC Version 2?",
587
- 819 => "MOC Version 1?",
588
- 820 => "MOC Version 2?",
808
+ 814 => "IZ2 Revision",
809
+ 815 => "AOC Installed",
810
+ 816 => "AOC Version",
811
+ 817 => "AOC Revision",
812
+ 818 => "MOC Installed",
813
+ 819 => "MOC Version",
814
+ 820 => "MOC Revision",
815
+ 824 => "EEV2 Installed",
589
816
  825 => "EEV2 Version",
817
+ 826 => "EEV2 Revision",
818
+ 827 => "AWL Installed",
590
819
  828 => "AWL Version",
820
+ 829 => "AWL Revision",
591
821
  900 => "Leaving Air",
592
822
  1103 => "AXB Inputs",
593
823
  1104 => "AXB Outputs",
@@ -595,27 +825,64 @@ module Aurora
595
825
  1106 => "Aux Amps",
596
826
  1107 => "Compressor 1 Amps",
597
827
  1108 => "Compressor 2 Amps",
598
- 1109 => "Heating Liquid Line",
828
+ 1109 => "Heating Liquid Line Temperature",
599
829
  1110 => "Leaving Water",
600
830
  1111 => "Entering Water",
601
- 1114 => "DHW Temp",
831
+ 1112 => "Leaving Air Temperature",
832
+ 1113 => "Suction Temperature",
833
+ 1114 => "DHW Temperature",
834
+ 1115 => "Discharge Pressure",
835
+ 1116 => "Suction Pressure",
602
836
  1117 => "Waterflow",
603
- 1134 => "Saturated Discharge Temperature",
604
- 1135 => "SubCooling",
605
- 1147 => "Compressor Watts",
606
- 1149 => "Blower Watts",
607
- 1151 => "Aux Watts",
608
- 1153 => "Total Watts",
609
- 1157 => "Ht of Rej",
610
- 1165 => "VS Pump Watts",
837
+ 1119 => "Loop Pressure", # only valid < 1000psi
838
+ 1124 => "Saturated Evaporator Temperature",
839
+ 1125 => "SuperHeat",
840
+ 1126 => "Vaport Injector Open %",
841
+ 1134 => "Saturated Condensor Discharge Temperature",
842
+ 1135 => "SubCooling (Heating)",
843
+ 1136 => "SubCooling (Cooling)",
844
+ 1146 => "Compressor Watts",
845
+ 1148 => "Blower Watts",
846
+ 1150 => "Aux Watts",
847
+ 1152 => "Total Watts",
848
+ 1154 => "Heat of Extraction",
849
+ 1156 => "Heat of Rejection",
850
+ 1164 => "Pump Watts",
611
851
  12_606 => "Heating Mode (write)",
612
852
  12_619 => "Heating Setpoint (write)",
613
853
  12_620 => "Cooling Setpoint (write)",
614
854
  12_621 => "Fan Mode (write)",
615
- 3000 => "Compressor Speed?",
616
- 3001 => "Compressor Speed?",
855
+ 3000 => "Compressor Speed Desired",
856
+ 3001 => "Compressor Speed Actual",
857
+ 3002 => "Manual Operation",
617
858
  3027 => "Compressor Speed",
618
- 3904 => "Leaving Air Temperature?",
859
+ 3220 => "VS Drive Details (General 1)",
860
+ 3221 => "VS Drive Details (General 2)",
861
+ 3222 => "VS Drive Details (Derate 1)",
862
+ 3223 => "VS Drive Details (Derate 2)",
863
+ 3224 => "VS Drive Details (Safemode 1)",
864
+ 3225 => "VS Drive Details (Safemode 2)",
865
+ 3226 => "VS Drive Details (Alarm 1)",
866
+ 3227 => "VS Drive Details (Alarm 2)",
867
+ 3327 => "VS Drive Temperature",
868
+ 3322 => "VS Drive Discharge Pressure",
869
+ 3323 => "VS Drive Suction Pressure",
870
+ 3325 => "VS Drive Discharge Temperature",
871
+ 3326 => "VS Drive Compressor Ambient Temperature",
872
+ 3330 => "VS Drive Entering Water Temperature",
873
+ 3331 => "VS Drive Line Voltage",
874
+ 3332 => "VS Drive Thermo Power",
875
+ 3422 => "VS Drive Compressor Power",
876
+ 3424 => "VS Drive Supply Voltage",
877
+ 3522 => "VS Drive Inverter Temperature",
878
+ 3523 => "VS Drive UDC Voltage",
879
+ 3524 => "VS Drive Fan Speed",
880
+ 3804 => "VS Drive Details (EEV2 Ctl)",
881
+ 3808 => "VS Drive SuperHeat Percent",
882
+ 3903 => "VS Drive Suction Temperature",
883
+ 3904 => "VS Drive Leaving Air Temperature?",
884
+ 3905 => "VS Drive Saturated Evaporator Discharge Temperature",
885
+ 3906 => "VS Drive SuperHeat Temperature",
619
886
  31_003 => "Outdoor Temp",
620
887
  31_005 => "IZ2 Demand",
621
888
  31_109 => "Humidifier Mode", # write to 21114
@@ -630,7 +897,10 @@ module Aurora
630
897
  .merge(ignore(93..104))
631
898
  .merge(ignore(106..109))
632
899
  .merge(faults(601..699))
900
+ .merge(ignore(711..717))
633
901
  .merge(zone_registers)
902
+ .merge(ignore(1147, 1149, 1151, 1153, 1155, 1157, 1165))
903
+ .merge(ignore(3423, 3425))
634
904
  .merge(ignore(31_401..31_412))
635
905
  .merge(ignore(31_414..31_420))
636
906
  .merge(ignore(31_422..31_433))