urbanopt-cli 0.9.2 → 0.10.0
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +4 -4
- data/.github/workflows/{nightly_build.yml → nightly_ci_build.yml} +6 -5
- data/CHANGELOG.md +16 -2
- data/CMakeLists.txt +7 -7
- data/Gemfile +8 -7
- data/LICENSE.md +18 -15
- data/README.md +2 -1
- data/Rakefile +2 -37
- data/example_files/Gemfile +10 -8
- data/example_files/mappers/Baseline.rb +170 -191
- data/example_files/mappers/ChilledWaterStorage.rb +8 -30
- data/example_files/mappers/ClassProject.rb +2 -27
- data/example_files/mappers/CreateBar.rb +2 -28
- data/example_files/mappers/EvCharging.rb +2 -27
- data/example_files/mappers/FlexibleHotWater.rb +2 -27
- data/example_files/mappers/Floorspace.rb +2 -27
- data/example_files/mappers/HighEfficiency.rb +2 -27
- data/example_files/mappers/HighEfficiencyCreateBar.rb +2 -27
- data/example_files/mappers/HighEfficiencyFloorspace.rb +2 -27
- data/example_files/mappers/PeakHoursMelsShedding.rb +4 -27
- data/example_files/mappers/PeakHoursThermostatAdjust.rb +4 -27
- data/example_files/mappers/ThermalStorage.rb +2 -28
- data/example_files/measures/BuildResidentialModel/measure.rb +30 -60
- data/example_files/measures/BuildResidentialModel/measure.xml +253 -84
- data/example_files/measures/BuildResidentialModel/resources/util.rb +45 -45
- data/example_files/python_deps/dependencies.json +3 -3
- data/example_files/resources/hpxml-measures/.github/pull_request_template.md +1 -1
- data/example_files/resources/hpxml-measures/.github/workflows/config.yml +28 -19
- data/example_files/resources/hpxml-measures/.gitignore +0 -997
- data/example_files/resources/hpxml-measures/.readthedocs.yml +9 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/measure.rb +476 -230
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/measure.xml +244 -75
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/geometry.rb +42 -15
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/build_residential_hpxml_test.rb +24 -9
- data/example_files/resources/hpxml-measures/BuildResidentialScheduleFile/measure.rb +11 -33
- data/example_files/resources/hpxml-measures/BuildResidentialScheduleFile/measure.xml +23 -50
- data/example_files/resources/hpxml-measures/BuildResidentialScheduleFile/resources/README.md +2 -2
- data/example_files/resources/hpxml-measures/BuildResidentialScheduleFile/resources/constants.rb +119 -0
- data/example_files/resources/hpxml-measures/BuildResidentialScheduleFile/resources/schedules.rb +67 -290
- data/example_files/resources/hpxml-measures/BuildResidentialScheduleFile/resources/schedules_config.md +6 -5
- data/example_files/resources/hpxml-measures/BuildResidentialScheduleFile/tests/build_residential_schedule_file_test.rb +78 -349
- data/example_files/resources/hpxml-measures/Changelog.md +80 -10
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/measure.rb +212 -144
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/measure.xml +164 -170
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/airflow.rb +238 -167
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/battery.rb +1 -1
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/constants.rb +12 -4
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/constructions.rb +36 -6
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/data/unavailable_periods.csv +33 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/energyplus.rb +1 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/geometry.rb +9 -7
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hotwater_appliances.rb +79 -61
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hpxml.rb +387 -124
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hpxml_defaults.rb +427 -196
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hpxml_schema/HPXML.xsd +11515 -2
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hpxml_schema/README.md +1 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hpxml_schematron/EPvalidator.xml +224 -85
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hvac.rb +334 -319
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hvac_sizing.rb +572 -838
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/lighting.rb +162 -68
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/location.rb +4 -20
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/meta_measure.rb +12 -10
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/misc_loads.rb +34 -37
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/output.rb +8 -101
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/psychrometrics.rb +31 -40
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/pv.rb +1 -1
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/schedule_files/occupancy-non-stochastic.csv +8761 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/schedule_files/occupancy-stochastic-10-mins.csv +52561 -52561
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/schedule_files/occupancy-stochastic.csv +8761 -8761
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/schedules.rb +384 -155
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/unit_conversions.rb +1 -1
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/util.rb +2 -2
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/version.rb +2 -2
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/waterheater.rb +68 -90
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/weather.rb +34 -223
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/xmlhelper.rb +1 -1
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/xmlvalidator.rb +16 -4
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_airflow.rb +94 -40
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_defaults.rb +765 -302
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_enclosure.rb +119 -69
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_generator.rb +8 -8
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_hotwater_appliance.rb +1 -1
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_hvac.rb +51 -11
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_hvac_sizing.rb +196 -9
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_lighting.rb +36 -13
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_miscloads.rb +3 -3
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_pv.rb +2 -2
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_schedules.rb +571 -61
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_validation.rb +190 -81
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_water_heater.rb +11 -11
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_weather.rb +188 -50
- data/example_files/resources/hpxml-measures/README.md +3 -3
- data/example_files/resources/hpxml-measures/ReportSimulationOutput/measure.rb +659 -815
- data/example_files/resources/hpxml-measures/ReportSimulationOutput/measure.xml +301 -1112
- data/example_files/resources/hpxml-measures/ReportSimulationOutput/tests/output_report_test.rb +605 -350
- data/example_files/resources/hpxml-measures/ReportUtilityBills/measure.rb +18 -14
- data/example_files/resources/hpxml-measures/ReportUtilityBills/measure.xml +15 -15
- data/example_files/resources/hpxml-measures/ReportUtilityBills/tests/utility_bills_test.rb +13 -3
- data/example_files/resources/hpxml-measures/docs/source/usage_instructions.rst +3 -3
- data/example_files/resources/hpxml-measures/docs/source/workflow_inputs.rst +894 -596
- data/example_files/resources/hpxml-measures/docs/source/workflow_outputs.rst +127 -76
- data/example_files/resources/hpxml-measures/tasks.rb +185 -2802
- data/example_files/resources/hpxml-measures/workflow/hpxml_inputs.json +3401 -0
- data/example_files/resources/hpxml-measures/workflow/real_homes/house001.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/real_homes/house002.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/real_homes/house003.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/real_homes/house004.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/real_homes/house005.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/real_homes/house006.xml +1 -3
- data/example_files/resources/hpxml-measures/workflow/real_homes/house007.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/real_homes/house008.xml +1 -3
- data/example_files/resources/hpxml-measures/workflow/real_homes/house009.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/real_homes/house010.xml +1 -3
- data/example_files/resources/hpxml-measures/workflow/real_homes/house011.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/real_homes/house012.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/real_homes/house013.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/real_homes/house014.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/real_homes/house015.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/real_homes/house016.xml +3 -4
- data/example_files/resources/hpxml-measures/workflow/real_homes/house017.xml +17 -4
- data/example_files/resources/hpxml-measures/workflow/real_homes/house018.xml +2 -3
- data/example_files/resources/hpxml-measures/workflow/real_homes/house019.xml +3 -4
- data/example_files/resources/hpxml-measures/workflow/real_homes/house020.xml +3 -4
- data/example_files/resources/hpxml-measures/workflow/real_homes/house021.xml +4 -5
- data/example_files/resources/hpxml-measures/workflow/real_homes/house022.xml +3 -4
- data/example_files/resources/hpxml-measures/workflow/real_homes/house023.xml +3 -4
- data/example_files/resources/hpxml-measures/workflow/real_homes/house024.xml +3 -4
- data/example_files/resources/hpxml-measures/workflow/real_homes/house025.xml +3 -4
- data/example_files/resources/hpxml-measures/workflow/real_homes/house026.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/real_homes/house027.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/real_homes/house028.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/real_homes/house029.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/real_homes/house030.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/real_homes/house031.xml +4 -5
- data/example_files/resources/hpxml-measures/workflow/real_homes/house032.xml +3 -3
- data/example_files/resources/hpxml-measures/workflow/real_homes/house033.xml +3 -3
- data/example_files/resources/hpxml-measures/workflow/real_homes/house034.xml +3 -4
- data/example_files/resources/hpxml-measures/workflow/real_homes/house035.xml +3 -3
- data/example_files/resources/hpxml-measures/workflow/real_homes/house036.xml +3 -4
- data/example_files/resources/hpxml-measures/workflow/real_homes/house037.xml +3 -3
- data/example_files/resources/hpxml-measures/workflow/real_homes/house038.xml +3 -4
- data/example_files/resources/hpxml-measures/workflow/real_homes/house039.xml +3 -3
- data/example_files/resources/hpxml-measures/workflow/real_homes/house040.xml +3 -4
- data/example_files/resources/hpxml-measures/workflow/real_homes/house041.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/real_homes/house042.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/real_homes/house043.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/real_homes/house044.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/real_homes/house045.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/real_homes/house046.xml +1 -0
- data/example_files/resources/hpxml-measures/workflow/real_homes/house047.xml +1 -0
- data/example_files/resources/hpxml-measures/workflow/run_simulation.rb +12 -8
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-coal.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-dehumidifier-ief-portable.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-dehumidifier-ief-whole-home.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-dehumidifier-multiple.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-dehumidifier.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-gas.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-modified.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-none.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-oil-location-miami-fl.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-oil.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-propane-location-portland-or.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-propane.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-wood.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-cathedral.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-conditioned.xml +9 -39
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-flat.xml +9 -39
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-radiant-barrier.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-unvented-insulated-roof.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-vented.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-battery-scheduled.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-battery.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-single-family-attached-2stories.xml → base-bldgtype-attached-2stories.xml} +610 -639
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-single-family-attached-atticroof-cathedral.xml → base-bldgtype-attached-atticroof-cathedral.xml} +558 -587
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-attached-infil-compartmentalization-test.xml +611 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-single-family-attached.xml → base-bldgtype-attached.xml} +610 -639
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-adjacent-to-multifamily-buffer-space.xml +10 -39
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-adjacent-to-multiple.xml +10 -39
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-adjacent-to-non-freezing-space.xml +10 -39
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-adjacent-to-other-heated-space.xml +10 -39
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-adjacent-to-other-housing-unit.xml +10 -39
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-infil-compartmentalization-test.xml +462 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-calctype-operational.xml → base-bldgtype-multifamily-residents-1.xml} +453 -480
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-chiller-baseboard.xml +10 -39
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-chiller-fan-coil-ducted.xml +10 -39
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-chiller-fan-coil.xml +10 -39
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-chiller-water-loop-heat-pump.xml +10 -39
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-cooling-tower-water-loop-heat-pump.xml +10 -39
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-only-baseboard.xml +10 -39
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-only-fan-coil-ducted.xml +10 -39
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-only-fan-coil-eae.xml +10 -39
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-only-fan-coil.xml +10 -39
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-only-water-loop-heat-pump.xml +10 -39
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-chiller-only-baseboard.xml +10 -39
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-chiller-only-fan-coil-ducted.xml +10 -39
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-chiller-only-fan-coil.xml +10 -39
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-chiller-only-water-loop-heat-pump.xml +10 -39
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-cooling-tower-only-water-loop-heat-pump.xml +10 -39
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-generator.xml +11 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-ground-loop-ground-to-air-heat-pump.xml +10 -39
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-laundry-room-multiple-water-heaters.xml +10 -39
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-laundry-room.xml +10 -39
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-mechvent-multiple.xml +10 -39
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-mechvent-preconditioning.xml +10 -39
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-mechvent.xml +10 -39
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-pv.xml +15 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-water-heater-recirc.xml +10 -39
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-water-heater.xml +10 -39
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily.xml +10 -39
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-combi-tankless-outside.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-combi-tankless.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-2-speed.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-gshp.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-hpwh.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-tankless.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-var-speed.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-dwhr.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect-detailed-setpoints.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect-dse.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect-outside.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect-standbyloss.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect-with-solar-fraction.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-jacket-electric.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-jacket-gas.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-jacket-hpwh.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-jacket-indirect.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-low-flow-fixtures.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-multiple.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-none.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-demand.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-manual.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-nocontrol.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-temperature.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-timer.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-direct-evacuated-tube.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-direct-flat-plate.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-direct-ics.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-fraction.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-indirect-flat-plate.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-thermosyphon-flat-plate.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-coal.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-detailed-setpoints.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-elec-uef.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-gas-outside.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-gas-uef-fhr.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-gas-uef.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-gas.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-detailed-schedules.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-operating-mode-heat-pump-only.xml +11 -43
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-outside.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-uef.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-with-solar-fraction.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-with-solar.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-model-type-stratified-detailed-occupancy-stochastic.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-model-type-stratified.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-oil.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-wood.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-detailed-setpoints.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-electric-outside.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-electric-uef.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-electric.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-gas-uef.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-gas-with-solar-fraction.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-gas-with-solar.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-gas.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-propane.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-2stories-garage.xml +19 -25
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-2stories.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-beds-1.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-beds-2.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-beds-4.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-beds-5.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-ceilingtypes.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-floortypes.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-garage.xml +18 -24
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-ach-house-pressure.xml +11 -41
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-cfm-house-pressure.xml +11 -41
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-cfm50.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-ela.xml +549 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-flue.xml +13 -43
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-natural-ach.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-natural-cfm.xml +552 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-orientations.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-overhangs.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-rooftypes.xml +17 -47
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-skylights-physical-properties.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-skylights-shading.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-skylights-storms.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-skylights.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-split-level.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-thermal-mass.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-walltypes.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-windows-natural-ventilation-availability.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-windows-none.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-windows-physical-properties.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-windows-shading-seasons.xml +559 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-windows-shading.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-windows-storms.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-ambient.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-basement-garage.xml +19 -25
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-complex.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-conditioned-basement-slab-insulation.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-conditioned-basement-wall-insulation.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-conditioned-crawlspace.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-multiple.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-slab.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unconditioned-basement-above-grade.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unconditioned-basement-assembly-r.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unconditioned-basement-wall-insulation.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unconditioned-basement.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unvented-crawlspace.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-vented-crawlspace.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-walkout-basement.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-1-speed-autosized-backup.xml +557 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-1-speed-cooling-only.xml +16 -41
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-hvac-dual-fuel-air-to-air-heat-pump-1-speed-electric.xml → base-hvac-air-to-air-heat-pump-1-speed-heating-capacity-17f.xml} +552 -583
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-1-speed-heating-only.xml +16 -41
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-hvac-air-to-air-heat-pump-1-speed-backup-lockout-temperature.xml → base-hvac-air-to-air-heat-pump-1-speed-lockout-temperatures.xml} +562 -586
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-1-speed-seer2-hspf2.xml +16 -41
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-1-speed.xml +16 -41
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-2-speed.xml +16 -41
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-var-speed-backup-boiler-hvac-seasons.xml +587 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-var-speed-backup-boiler-switchover-temperature.xml +17 -42
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-var-speed-backup-boiler.xml +16 -41
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-var-speed-backup-furnace.xml +16 -41
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-var-speed.xml +16 -41
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-1-speed-cooling-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-1-speed-heating-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-1-speed-sizing-methodology-acca.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-1-speed-sizing-methodology-hers.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-1-speed-sizing-methodology-maxload-miami-fl.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-1-speed-sizing-methodology-maxload.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-2-speed-sizing-methodology-acca.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-2-speed-sizing-methodology-hers.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-2-speed-sizing-methodology-maxload.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-var-speed-backup-boiler.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-var-speed-backup-furnace.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-var-speed-sizing-methodology-acca.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-var-speed-sizing-methodology-hers.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-var-speed-sizing-methodology-maxload.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-boiler-elec-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-boiler-gas-central-ac-1-speed.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-boiler-gas-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-central-ac-only-1-speed.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-central-ac-only-2-speed.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-central-ac-only-var-speed.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-central-ac-plus-air-to-air-heat-pump-heating.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-dual-fuel-air-to-air-heat-pump-1-speed-sizing-methodology-acca.xml +11 -41
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-dual-fuel-air-to-air-heat-pump-1-speed-sizing-methodology-hers.xml +11 -41
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-dual-fuel-air-to-air-heat-pump-1-speed-sizing-methodology-maxload.xml +11 -41
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-dual-fuel-mini-split-heat-pump-ducted-backup-hardsized.xml +553 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-dual-fuel-mini-split-heat-pump-ducted.xml +11 -41
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-elec-resistance-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-evap-cooler-furnace-gas.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-floor-furnace-propane-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-furnace-elec-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-furnace-gas-central-ac-2-speed.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-furnace-gas-central-ac-var-speed.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-furnace-gas-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-furnace-gas-room-ac.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-ground-to-air-heat-pump-cooling-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-ground-to-air-heat-pump-heating-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-ground-to-air-heat-pump-sizing-methodology-acca.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-ground-to-air-heat-pump-sizing-methodology-hers.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-ground-to-air-heat-pump-sizing-methodology-maxload.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-mini-split-air-conditioner-only-ducted.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-mini-split-heat-pump-ducted-cooling-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-mini-split-heat-pump-ducted-heating-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-mini-split-heat-pump-ducted-sizing-methodology-acca.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-mini-split-heat-pump-ducted-sizing-methodology-hers.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-mini-split-heat-pump-ducted-sizing-methodology-maxload.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-mini-split-heat-pump-ductless-backup-baseboard.xml +519 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-mini-split-heat-pump-ductless-backup-stove.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-ptac-with-heating.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-ptac.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-pthp-sizing-methodology-acca.xml +16 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-pthp-sizing-methodology-hers.xml +16 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-pthp-sizing-methodology-maxload.xml +16 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-room-ac-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-room-ac-with-heating.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-room-ac-with-reverse-cycle-sizing-methodology-acca.xml +16 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-room-ac-with-reverse-cycle-sizing-methodology-hers.xml +16 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-room-ac-with-reverse-cycle-sizing-methodology-maxload.xml +16 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-sizing-controls.xml +566 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-stove-oil-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-wall-furnace-elec-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-coal-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-elec-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-gas-central-ac-1-speed.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-gas-only-pilot.xml +513 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-gas-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-oil-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-propane-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-wood-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-central-ac-only-1-speed-seer2.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-central-ac-only-1-speed.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-central-ac-only-2-speed.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-central-ac-only-var-speed.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-central-ac-plus-air-to-air-heat-pump-heating.xml +16 -41
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-crankcase-heater-40w.xml +556 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dse.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-air-to-air-heat-pump-1-speed-lockout-temperatures.xml +560 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-air-to-air-heat-pump-1-speed.xml +17 -42
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-air-to-air-heat-pump-2-speed.xml +17 -42
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-air-to-air-heat-pump-var-speed.xml +17 -42
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-mini-split-heat-pump-ducted.xml +17 -42
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ducts-area-fractions.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ducts-area-multipliers.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ducts-buried.xml +555 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ducts-effective-rvalue.xml +553 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ducts-leakage-cfm50.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ducts-leakage-percent.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-elec-resistance-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-evap-cooler-furnace-gas.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-evap-cooler-only-ducted.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-evap-cooler-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-fireplace-wood-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-fixed-heater-gas-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-floor-furnace-propane-only-pilot-light.xml +506 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-floor-furnace-propane-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-coal-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-elec-central-ac-1-speed.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-elec-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-central-ac-2-speed.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-central-ac-var-speed.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-only-detailed-setpoints.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-only-pilot.xml +542 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-room-ac.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-oil-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-propane-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-wood-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-x3-dse.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ground-to-air-heat-pump-cooling-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ground-to-air-heat-pump-heating-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ground-to-air-heat-pump.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-air-to-air-heat-pump-1-speed.xml +14 -41
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-air-to-air-heat-pump-2-speed.xml +14 -41
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-air-to-air-heat-pump-var-speed.xml +14 -41
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-furnace-gas-central-ac-1-speed.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-furnace-gas-central-ac-2-speed.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-furnace-gas-central-ac-var-speed.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-furnace-gas-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-ground-to-air-heat-pump.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-mini-split-air-conditioner-only-ducted.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-mini-split-heat-pump-ducted.xml +14 -41
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-air-conditioner-only-ducted.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-air-conditioner-only-ductless.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ducted-cooling-only.xml +16 -41
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ducted-heating-only.xml +16 -41
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ducted.xml +16 -41
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ductless-backup-baseboard.xml +525 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ductless-backup-furnace.xml +564 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ductless-backup-stove.xml +16 -41
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ductless-heating-capacity-17f.xml +506 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ductless.xml +16 -41
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-multiple.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-none.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-portable-heater-gas-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ptac-with-heating-electricity.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ptac-with-heating-natural-gas.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ptac.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-pthp-heating-capacity-17f.xml +513 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-pthp.xml +16 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-room-ac-only-33percent.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-room-ac-only-ceer.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-room-ac-only-detailed-setpoints.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-room-ac-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-room-ac-with-heating.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-room-ac-with-reverse-cycle.xml +16 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-seasons.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-setpoints-daily-schedules.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-setpoints-daily-setbacks.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-setpoints.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-stove-oil-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-stove-wood-pellets-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-undersized-allow-increased-fixed-capacities.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-undersized.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-wall-furnace-elec-only.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-lighting-ceiling-fans.xml +11 -41
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-lighting-holiday.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-lighting-kwh-per-year.xml +529 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-lighting-mixed.xml +537 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-lighting-none-ceiling-fans.xml +516 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-lighting-none.xml +1 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-AMY-2012.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-baltimore-md.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-capetown-zaf.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-dallas-tx.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-duluth-mn.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-helena-mt.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-honolulu-hi.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-miami-fl.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-phoenix-az.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-portland-or.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-balanced.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-bath-kitchen-fans.xml +12 -42
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-cfis-airflow-fraction-zero.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-cfis-dse.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-cfis-evap-cooler-only-ducted.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-cfis-supplemental-fan-exhaust.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-cfis-supplemental-fan-supply.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-cfis.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-erv-atre-asre.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-erv.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-exhaust-rated-flow-rate.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-exhaust.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-hrv-asre.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-hrv.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-multiple.xml +14 -44
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-supply.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-whole-house-fan.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-additional-properties.xml +10 -38
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-bills-none.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-bills-pv-detailed-only.xml +16 -42
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-bills-pv-mixed.xml +16 -42
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-bills-pv.xml +16 -42
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-bills.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-defaults.xml +14 -37
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-emissions.xml +16 -42
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-generators-battery-scheduled.xml +12 -42
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-generators-battery.xml +12 -42
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-generators.xml +12 -42
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-ground-conductivity.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-loads-large-uncommon.xml +10 -38
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-loads-large-uncommon2.xml +10 -38
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-loads-none.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-neighbor-shading-bldgtype-multifamily.xml +509 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-neighbor-shading.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-shielding-of-home.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-usage-multiplier.xml +10 -41
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-multiple-buildings.xml +30 -138
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv-battery-ah.xml +16 -42
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv-battery-garage.xml +24 -26
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv-battery-round-trip-efficiency.xml +16 -42
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv-battery-scheduled.xml +16 -42
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv-battery.xml +16 -42
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv-generators-battery-scheduled.xml +18 -44
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv-generators-battery.xml +18 -44
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv-generators.xml +18 -44
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv.xml +16 -42
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-residents-0-runperiod-1-month.xml +560 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-residents-0.xml +556 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-calctype-operational-misc-loads-large-uncommon.xml → base-residents-1-misc-loads-large-uncommon.xml} +616 -644
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-calctype-operational-misc-loads-large-uncommon2.xml → base-residents-1-misc-loads-large-uncommon2.xml} +616 -644
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-calctype-operational.xml → base-residents-1.xml} +547 -575
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-calctype-operational-misc-defaults.xml → base-residents-5.xml} +515 -539
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-detailed-all-10-mins.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-detailed-occupancy-stochastic-10-mins.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-detailed-occupancy-stochastic-power-outage.xml +565 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-schedules-detailed-occupancy-smooth.xml → base-schedules-detailed-occupancy-stochastic-vacancy-year-round.xml} +563 -583
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-detailed-occupancy-stochastic-vacancy.xml +21 -41
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-detailed-occupancy-stochastic.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-detailed-setpoints-daily-schedules.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-detailed-setpoints-daily-setbacks.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-detailed-setpoints.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-simple-power-outage-natvent-available.xml +565 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-simple-power-outage-natvent-unavailable.xml +565 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-simple-power-outage.xml +620 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-simple-vacancy-year-round.xml +619 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-simple-vacancy.xml +619 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-simple.xml +10 -38
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-calendar-year-custom.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-daylight-saving-custom.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-daylight-saving-disabled.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-runperiod-1-month.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-temperature-capacitance-multiplier.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-timestep-10-mins-occupancy-stochastic-10-mins.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-timestep-10-mins-occupancy-stochastic-60-mins.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-timestep-10-mins.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-timestep-30-mins.xml +10 -40
- data/example_files/resources/hpxml-measures/workflow/sample_files/base.xml +10 -37
- data/example_files/resources/hpxml-measures/workflow/template-build-and-run-hpxml-with-stochastic-occupancy.osw +16 -4
- data/example_files/resources/hpxml-measures/workflow/template-run-hpxml-with-stochastic-occupancy-subset.osw +16 -3
- data/example_files/resources/hpxml-measures/workflow/template-run-hpxml-with-stochastic-occupancy.osw +16 -3
- data/example_files/resources/hpxml-measures/workflow/template-run-hpxml.osw +16 -2
- data/example_files/resources/hpxml-measures/workflow/tests/ACCA_Examples/Long_Residence.xml +386 -0
- data/example_files/resources/hpxml-measures/workflow/tests/ACCA_Examples/Vatilo_Residence.xml +381 -0
- data/example_files/resources/hpxml-measures/workflow/tests/ACCA_Examples/Victor_Residence.xml +370 -0
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L100AC.xml +2 -2
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L100AL.xml +2 -5
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L110AC.xml +2 -5
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L110AL.xml +2 -5
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L120AC.xml +2 -5
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L120AL.xml +2 -5
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L130AC.xml +2 -5
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L130AL.xml +2 -5
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L140AC.xml +2 -5
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L140AL.xml +2 -5
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L150AC.xml +2 -5
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L150AL.xml +2 -5
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L155AC.xml +2 -5
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L155AL.xml +2 -5
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L160AC.xml +2 -5
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L160AL.xml +2 -5
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L170AC.xml +2 -12
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L170AL.xml +2 -12
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L200AC.xml +2 -5
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L200AL.xml +2 -5
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L202AC.xml +2 -5
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L202AL.xml +2 -5
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L302XC.xml +2 -5
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L304XC.xml +2 -5
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L322XC.xml +6 -9
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L324XC.xml +6 -9
- data/example_files/resources/hpxml-measures/workflow/tests/base_results/results.csv +475 -444
- data/example_files/resources/hpxml-measures/workflow/tests/base_results/results_bills.csv +475 -444
- data/example_files/resources/hpxml-measures/workflow/tests/hpxml_translator_test.rb +177 -112
- data/example_files/resources/meta_measure.rb +2 -27
- data/example_files/xml_building/17/README.md +3 -3
- data/lib/uo_cli/version.rb +3 -38
- data/lib/uo_cli.rb +3 -38
- data/uo_cli.gemspec +6 -7
- metadata +70 -51
- data/example_files/resources/hpxml-measures/BuildResidentialScheduleFile/resources/schedules_config.json +0 -388
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hpxml_schema/HPXMLBaseElements.xsd +0 -6136
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hpxml_schema/HPXMLDataTypes.xsd +0 -4846
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/schedule_files/occupancy-smooth.csv +0 -8761
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/schedule_files/occupancy-stochastic-vacancy.csv +0 -8761
- data/example_files/resources/hpxml-measures/weather/USA_AZ_Phoenix-Sky.Harbor.Intl.AP.722780_TMY3-cache.csv +0 -35
- data/example_files/resources/hpxml-measures/weather/USA_CO_Colorado.Springs-Peterson.Field.724660_TMY3-cache.csv +0 -35
- data/example_files/resources/hpxml-measures/weather/USA_CO_Denver.Intl.AP.725650_TMY3-cache.csv +0 -35
- data/example_files/resources/hpxml-measures/weather/USA_DE_Wilmington-New.Castle.County.AP.724089_TMY3-cache.csv +0 -35
- data/example_files/resources/hpxml-measures/weather/USA_FL_Miami.Intl.AP.722020_TMY3-cache.csv +0 -35
- data/example_files/resources/hpxml-measures/weather/USA_HI_Honolulu.Intl.AP.911820_TMY3-cache.csv +0 -35
- data/example_files/resources/hpxml-measures/weather/USA_MD_Baltimore-Washington.Intl.AP.724060_TMY3-cache.csv +0 -35
- data/example_files/resources/hpxml-measures/weather/USA_MN_Duluth.Intl.AP.727450_TMY3-cache.csv +0 -35
- data/example_files/resources/hpxml-measures/weather/USA_MT_Helena.Rgnl.AP.727720_TMY3-cache.csv +0 -35
- data/example_files/resources/hpxml-measures/weather/USA_NC_Charlotte-Douglas.Intl.AP.723140_TMY3-cache.csv +0 -35
- data/example_files/resources/hpxml-measures/weather/USA_NJ_Cape.May.County.AP.745966_TMY3-cache.csv +0 -35
- data/example_files/resources/hpxml-measures/weather/USA_NV_Las.Vegas-McCarran.Intl.AP.723860_TMY3-cache.csv +0 -35
- data/example_files/resources/hpxml-measures/weather/USA_OR_Portland.Intl.AP.726980_TMY3-cache.csv +0 -35
- data/example_files/resources/hpxml-measures/weather/USA_TX_Dallas-Fort.Worth.Intl.AP.722590_TMY3-cache.csv +0 -35
- data/example_files/resources/hpxml-measures/weather/US_CO_Boulder_AMY_2012-cache.csv +0 -35
- data/example_files/resources/hpxml-measures/weather/ZAF_Cape.Town.688160_IWEC-cache.csv +0 -35
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-split-surfaces.xml +0 -2508
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-split-surfaces2.xml +0 -2508
@@ -13,13 +13,10 @@ class HPXMLtoOpenStudioEnclosureTest < MiniTest::Test
|
|
13
13
|
@root_path = File.absolute_path(File.join(File.dirname(__FILE__), '..', '..'))
|
14
14
|
@sample_files_path = File.join(@root_path, 'workflow', 'sample_files')
|
15
15
|
@tmp_hpxml_path = File.join(@sample_files_path, 'tmp.xml')
|
16
|
-
@tmp_output_path = File.join(@sample_files_path, 'tmp_output')
|
17
|
-
FileUtils.mkdir_p(@tmp_output_path)
|
18
16
|
end
|
19
17
|
|
20
18
|
def teardown
|
21
19
|
File.delete(@tmp_hpxml_path) if File.exist? @tmp_hpxml_path
|
22
|
-
FileUtils.rm_rf(@tmp_output_path)
|
23
20
|
end
|
24
21
|
|
25
22
|
def test_roofs
|
@@ -38,7 +35,7 @@ class HPXMLtoOpenStudioEnclosureTest < MiniTest::Test
|
|
38
35
|
model, hpxml = _test_measure(args_hash)
|
39
36
|
|
40
37
|
# Check properties
|
41
|
-
os_surface = model.getSurfaces.
|
38
|
+
os_surface = model.getSurfaces.find { |s| s.name.to_s.start_with? "#{hpxml.roofs[0].id}:" }
|
42
39
|
_check_surface(hpxml.roofs[0], os_surface, roof_values[:layer_names])
|
43
40
|
end
|
44
41
|
|
@@ -54,7 +51,7 @@ class HPXMLtoOpenStudioEnclosureTest < MiniTest::Test
|
|
54
51
|
model, hpxml = _test_measure(args_hash)
|
55
52
|
|
56
53
|
# Check properties
|
57
|
-
os_surface = model.getSurfaces.
|
54
|
+
os_surface = model.getSurfaces.find { |s| s.name.to_s.start_with? "#{hpxml.roofs[0].id}:" }
|
58
55
|
_check_surface(hpxml.roofs[0], os_surface, roof_values[:layer_names])
|
59
56
|
end
|
60
57
|
|
@@ -103,7 +100,7 @@ class HPXMLtoOpenStudioEnclosureTest < MiniTest::Test
|
|
103
100
|
model, hpxml = _test_measure(args_hash)
|
104
101
|
|
105
102
|
# Check properties
|
106
|
-
os_surface = model.getSurfaces.
|
103
|
+
os_surface = model.getSurfaces.find { |s| s.name.to_s.start_with? "#{hpxml.roofs[i].id}:" }
|
107
104
|
_check_surface(hpxml.roofs[i], os_surface, roof_values[:layer_names])
|
108
105
|
end
|
109
106
|
end
|
@@ -124,7 +121,7 @@ class HPXMLtoOpenStudioEnclosureTest < MiniTest::Test
|
|
124
121
|
model, hpxml = _test_measure(args_hash)
|
125
122
|
|
126
123
|
# Check properties
|
127
|
-
os_surface = model.getSurfaces.
|
124
|
+
os_surface = model.getSurfaces.find { |s| s.name.to_s.start_with? "#{hpxml.roofs[0].id}:" }
|
128
125
|
_check_surface(hpxml.roofs[0], os_surface, roof_values[:layer_names])
|
129
126
|
end
|
130
127
|
end
|
@@ -145,7 +142,7 @@ class HPXMLtoOpenStudioEnclosureTest < MiniTest::Test
|
|
145
142
|
model, hpxml = _test_measure(args_hash)
|
146
143
|
|
147
144
|
# Check properties
|
148
|
-
os_surface = model.getSurfaces.
|
145
|
+
os_surface = model.getSurfaces.find { |s| s.name.to_s.start_with? "#{hpxml.rim_joists[0].id}:" }
|
149
146
|
_check_surface(hpxml.rim_joists[0], os_surface, rimj_values[:layer_names])
|
150
147
|
end
|
151
148
|
|
@@ -201,7 +198,7 @@ class HPXMLtoOpenStudioEnclosureTest < MiniTest::Test
|
|
201
198
|
model, hpxml = _test_measure(args_hash)
|
202
199
|
|
203
200
|
# Check properties
|
204
|
-
os_surface = model.getSurfaces.
|
201
|
+
os_surface = model.getSurfaces.find { |s| s.name.to_s.start_with? "#{hpxml.rim_joists[i].id}:" }
|
205
202
|
_check_surface(hpxml.rim_joists[i], os_surface, rimj_values[:layer_names])
|
206
203
|
end
|
207
204
|
end
|
@@ -223,7 +220,7 @@ class HPXMLtoOpenStudioEnclosureTest < MiniTest::Test
|
|
223
220
|
model, hpxml = _test_measure(args_hash)
|
224
221
|
|
225
222
|
# Check properties
|
226
|
-
os_surface = model.getSurfaces.
|
223
|
+
os_surface = model.getSurfaces.find { |s| s.name.to_s.start_with? "#{hpxml.walls[0].id}:" }
|
227
224
|
_check_surface(hpxml.walls[0], os_surface, wall_values[:layer_names])
|
228
225
|
end
|
229
226
|
|
@@ -283,7 +280,7 @@ class HPXMLtoOpenStudioEnclosureTest < MiniTest::Test
|
|
283
280
|
model, hpxml = _test_measure(args_hash)
|
284
281
|
|
285
282
|
# Check properties
|
286
|
-
os_surface = model.getSurfaces.
|
283
|
+
os_surface = model.getSurfaces.find { |s| s.name.to_s.start_with? "#{hpxml.walls[i].id}:" }
|
287
284
|
_check_surface(hpxml.walls[i], os_surface, wall_values[:layer_names])
|
288
285
|
end
|
289
286
|
end
|
@@ -305,7 +302,7 @@ class HPXMLtoOpenStudioEnclosureTest < MiniTest::Test
|
|
305
302
|
model, hpxml = _test_measure(args_hash)
|
306
303
|
|
307
304
|
# Check properties
|
308
|
-
os_surface = model.getSurfaces.
|
305
|
+
os_surface = model.getSurfaces.find { |s| s.name.to_s == hpxml.foundation_walls[0].id }
|
309
306
|
_check_surface(hpxml.foundation_walls[0], os_surface, wall_values[:layer_names])
|
310
307
|
end
|
311
308
|
|
@@ -327,7 +324,7 @@ class HPXMLtoOpenStudioEnclosureTest < MiniTest::Test
|
|
327
324
|
model, hpxml = _test_measure(args_hash)
|
328
325
|
|
329
326
|
# Check properties
|
330
|
-
os_surface = model.getSurfaces.
|
327
|
+
os_surface = model.getSurfaces.find { |s| s.name.to_s == hpxml.foundation_walls[0].id }
|
331
328
|
_check_surface(hpxml.foundation_walls[0], os_surface, wall_values[:layer_names])
|
332
329
|
end
|
333
330
|
|
@@ -352,7 +349,7 @@ class HPXMLtoOpenStudioEnclosureTest < MiniTest::Test
|
|
352
349
|
model, hpxml = _test_measure(args_hash)
|
353
350
|
|
354
351
|
# Check properties
|
355
|
-
os_surface = model.getSurfaces.
|
352
|
+
os_surface = model.getSurfaces.find { |s| s.name.to_s == hpxml.foundation_walls[0].id }
|
356
353
|
_check_surface(hpxml.foundation_walls[0], os_surface, wall_values[:layer_names])
|
357
354
|
end
|
358
355
|
end
|
@@ -373,7 +370,7 @@ class HPXMLtoOpenStudioEnclosureTest < MiniTest::Test
|
|
373
370
|
model, hpxml = _test_measure(args_hash)
|
374
371
|
|
375
372
|
# Check properties
|
376
|
-
os_surface = model.getSurfaces.
|
373
|
+
os_surface = model.getSurfaces.find { |s| s.name.to_s == hpxml.floors[1].id }
|
377
374
|
_check_surface(hpxml.floors[1], os_surface, ceiling_values[:layer_names])
|
378
375
|
end
|
379
376
|
|
@@ -401,7 +398,7 @@ class HPXMLtoOpenStudioEnclosureTest < MiniTest::Test
|
|
401
398
|
model, hpxml = _test_measure(args_hash)
|
402
399
|
|
403
400
|
# Check properties
|
404
|
-
os_surface = model.getSurfaces.
|
401
|
+
os_surface = model.getSurfaces.find { |s| s.name.to_s.start_with? "#{hpxml.floors[i].id}" }
|
405
402
|
_check_surface(hpxml.floors[i], os_surface, ceiling_values[:layer_names])
|
406
403
|
end
|
407
404
|
end
|
@@ -423,7 +420,7 @@ class HPXMLtoOpenStudioEnclosureTest < MiniTest::Test
|
|
423
420
|
model, hpxml = _test_measure(args_hash)
|
424
421
|
|
425
422
|
# Check properties
|
426
|
-
os_surface = model.getSurfaces.
|
423
|
+
os_surface = model.getSurfaces.find { |s| s.name.to_s == hpxml.floors[0].id }
|
427
424
|
_check_surface(hpxml.floors[0], os_surface, floor_values[:layer_names])
|
428
425
|
end
|
429
426
|
|
@@ -451,7 +448,7 @@ class HPXMLtoOpenStudioEnclosureTest < MiniTest::Test
|
|
451
448
|
model, hpxml = _test_measure(args_hash)
|
452
449
|
|
453
450
|
# Check properties
|
454
|
-
os_surface = model.getSurfaces.
|
451
|
+
os_surface = model.getSurfaces.find { |s| s.name.to_s.start_with? "#{hpxml.floors[i].id}" }
|
455
452
|
_check_surface(hpxml.floors[i], os_surface, floor_values[:layer_names])
|
456
453
|
end
|
457
454
|
end
|
@@ -489,7 +486,7 @@ class HPXMLtoOpenStudioEnclosureTest < MiniTest::Test
|
|
489
486
|
model, hpxml = _test_measure(args_hash)
|
490
487
|
|
491
488
|
# Check properties
|
492
|
-
os_surface = model.getSurfaces.
|
489
|
+
os_surface = model.getSurfaces.find { |s| s.name.to_s == hpxml.slabs[0].id }
|
493
490
|
_check_surface(hpxml.slabs[0], os_surface, slab_values[:layer_names])
|
494
491
|
end
|
495
492
|
end
|
@@ -501,7 +498,7 @@ class HPXMLtoOpenStudioEnclosureTest < MiniTest::Test
|
|
501
498
|
|
502
499
|
# Check window properties
|
503
500
|
hpxml.windows.each do |window|
|
504
|
-
os_window = model.getSubSurfaces.
|
501
|
+
os_window = model.getSubSurfaces.find { |w| w.name.to_s == window.id }
|
505
502
|
os_simple_glazing = os_window.construction.get.to_LayeredConstruction.get.getLayer(0).to_SimpleGlazing.get
|
506
503
|
|
507
504
|
assert_equal(window.shgc, os_simple_glazing.solarHeatGainCoefficient)
|
@@ -521,7 +518,7 @@ class HPXMLtoOpenStudioEnclosureTest < MiniTest::Test
|
|
521
518
|
|
522
519
|
# Check window properties
|
523
520
|
hpxml.windows.each do |window|
|
524
|
-
os_window = model.getSubSurfaces.
|
521
|
+
os_window = model.getSubSurfaces.find { |w| w.name.to_s == window.id }
|
525
522
|
os_simple_glazing = os_window.construction.get.to_LayeredConstruction.get.getLayer(0).to_SimpleGlazing.get
|
526
523
|
|
527
524
|
assert_equal(0.36, os_simple_glazing.solarHeatGainCoefficient)
|
@@ -553,7 +550,7 @@ class HPXMLtoOpenStudioEnclosureTest < MiniTest::Test
|
|
553
550
|
sf_winter *= window.exterior_shading_factor_winter unless window.exterior_shading_factor_winter.nil?
|
554
551
|
|
555
552
|
# Check shading transmittance for sky beam and sky diffuse
|
556
|
-
os_shading_surface = model.getShadingSurfaces.
|
553
|
+
os_shading_surface = model.getShadingSurfaces.find { |ss| ss.name.to_s.start_with? window.id }
|
557
554
|
if (sf_summer == 1) && (sf_winter == 1)
|
558
555
|
assert_nil(os_shading_surface) # No shading
|
559
556
|
else
|
@@ -571,7 +568,7 @@ class HPXMLtoOpenStudioEnclosureTest < MiniTest::Test
|
|
571
568
|
|
572
569
|
# Check subsurface view factor to ground
|
573
570
|
subsurface_view_factor = 0.5
|
574
|
-
window_actuator = model.getEnergyManagementSystemActuators.
|
571
|
+
window_actuator = model.getEnergyManagementSystemActuators.find { |w| w.actuatedComponent.get.name.to_s == window.id }
|
575
572
|
program_values = get_ems_values(model.getEnergyManagementSystemPrograms, 'fixedwindow view factor to ground program')
|
576
573
|
assert_equal(subsurface_view_factor, program_values["#{window_actuator.name}"][0])
|
577
574
|
end
|
@@ -585,7 +582,7 @@ class HPXMLtoOpenStudioEnclosureTest < MiniTest::Test
|
|
585
582
|
|
586
583
|
# Check skylight properties
|
587
584
|
hpxml.skylights.each do |skylight|
|
588
|
-
os_skylight = model.getSubSurfaces.
|
585
|
+
os_skylight = model.getSubSurfaces.find { |w| w.name.to_s == skylight.id }
|
589
586
|
os_simple_glazing = os_skylight.construction.get.to_LayeredConstruction.get.getLayer(0).to_SimpleGlazing.get
|
590
587
|
|
591
588
|
assert_equal(skylight.shgc, os_simple_glazing.solarHeatGainCoefficient)
|
@@ -617,7 +614,7 @@ class HPXMLtoOpenStudioEnclosureTest < MiniTest::Test
|
|
617
614
|
sf_winter *= skylight.exterior_shading_factor_winter unless skylight.exterior_shading_factor_winter.nil?
|
618
615
|
|
619
616
|
# Check shading transmittance for sky beam and sky diffuse
|
620
|
-
os_shading_surface = model.getShadingSurfaces.
|
617
|
+
os_shading_surface = model.getShadingSurfaces.find { |ss| ss.name.to_s.start_with? skylight.id }
|
621
618
|
if (sf_summer == 1) && (sf_winter == 1)
|
622
619
|
assert_nil(os_shading_surface) # No shading
|
623
620
|
else
|
@@ -635,7 +632,7 @@ class HPXMLtoOpenStudioEnclosureTest < MiniTest::Test
|
|
635
632
|
|
636
633
|
# Check subsurface view factor to ground
|
637
634
|
subsurface_view_factor = 0.05 # 6:12 pitch
|
638
|
-
skylight_actuator = model.getEnergyManagementSystemActuators.
|
635
|
+
skylight_actuator = model.getEnergyManagementSystemActuators.find { |w| w.actuatedComponent.get.name.to_s == skylight.id }
|
639
636
|
program_values = get_ems_values(model.getEnergyManagementSystemPrograms, 'skylight view factor to ground program')
|
640
637
|
assert_equal(subsurface_view_factor, program_values["#{skylight_actuator.name}"][0])
|
641
638
|
end
|
@@ -658,7 +655,7 @@ class HPXMLtoOpenStudioEnclosureTest < MiniTest::Test
|
|
658
655
|
model, hpxml = _test_measure(args_hash)
|
659
656
|
|
660
657
|
# Check properties
|
661
|
-
os_surface = model.getSubSurfaces.
|
658
|
+
os_surface = model.getSubSurfaces.find { |s| s.name.to_s == hpxml.doors[0].id }
|
662
659
|
_check_surface(hpxml.doors[0], os_surface, door_values[:layer_names])
|
663
660
|
end
|
664
661
|
end
|
@@ -673,7 +670,7 @@ class HPXMLtoOpenStudioEnclosureTest < MiniTest::Test
|
|
673
670
|
model, hpxml = _test_measure(args_hash)
|
674
671
|
|
675
672
|
# Check properties
|
676
|
-
os_surface = model.getInternalMassDefinitions.
|
673
|
+
os_surface = model.getInternalMassDefinitions.find { |s| s.name.to_s == 'partition wall mass' }
|
677
674
|
_check_surface(hpxml.partition_wall_mass, os_surface, partition_wall_mass_layer_names)
|
678
675
|
end
|
679
676
|
|
@@ -687,45 +684,10 @@ class HPXMLtoOpenStudioEnclosureTest < MiniTest::Test
|
|
687
684
|
model, hpxml = _test_measure(args_hash)
|
688
685
|
|
689
686
|
# Check properties
|
690
|
-
os_surface = model.getInternalMassDefinitions.
|
687
|
+
os_surface = model.getInternalMassDefinitions.find { |s| s.name.to_s.start_with?('furniture mass living space') }
|
691
688
|
_check_surface(hpxml.furniture_mass, os_surface, furniture_mass_layer_names)
|
692
689
|
end
|
693
690
|
|
694
|
-
def test_compartmentaliztion_area
|
695
|
-
# Test single-family detached
|
696
|
-
hpxml = _create_hpxml('base.xml')
|
697
|
-
total_area, exterior_area = hpxml.compartmentalization_boundary_areas()
|
698
|
-
a_ext_ratio = exterior_area / total_area
|
699
|
-
assert_equal(1.0, a_ext_ratio)
|
700
|
-
|
701
|
-
hpxml = _create_hpxml('base-foundation-unconditioned-basement.xml')
|
702
|
-
total_area, exterior_area = hpxml.compartmentalization_boundary_areas()
|
703
|
-
a_ext_ratio = exterior_area / total_area
|
704
|
-
assert_equal(1.0, a_ext_ratio)
|
705
|
-
|
706
|
-
hpxml = _create_hpxml('base-atticroof-cathedral.xml')
|
707
|
-
total_area, exterior_area = hpxml.compartmentalization_boundary_areas()
|
708
|
-
a_ext_ratio = exterior_area / total_area
|
709
|
-
assert_equal(1.0, a_ext_ratio)
|
710
|
-
|
711
|
-
# Test single-family attached
|
712
|
-
hpxml = _create_hpxml('base-bldgtype-single-family-attached.xml')
|
713
|
-
total_area, exterior_area = hpxml.compartmentalization_boundary_areas()
|
714
|
-
a_ext_ratio = exterior_area / total_area
|
715
|
-
assert_in_delta(0.840, a_ext_ratio, 0.001)
|
716
|
-
|
717
|
-
hpxml.attics[0].within_infiltration_volume = true
|
718
|
-
total_area, exterior_area = hpxml.compartmentalization_boundary_areas()
|
719
|
-
a_ext_ratio = exterior_area / total_area
|
720
|
-
assert_in_delta(0.817, a_ext_ratio, 0.001)
|
721
|
-
|
722
|
-
# Test multifamily
|
723
|
-
hpxml = _create_hpxml('base-bldgtype-multifamily.xml')
|
724
|
-
total_area, exterior_area = hpxml.compartmentalization_boundary_areas()
|
725
|
-
a_ext_ratio = exterior_area / total_area
|
726
|
-
assert_in_delta(0.247, a_ext_ratio, 0.001)
|
727
|
-
end
|
728
|
-
|
729
691
|
def test_kiva_initial_temperatures
|
730
692
|
initial_temps = { 'base.xml' => 68.0, # foundation adjacent to conditioned space, IECC zone 5
|
731
693
|
'base-foundation-conditioned-crawlspace.xml' => 68.0, # foundation adjacent to conditioned space, IECC zone 5
|
@@ -746,11 +708,99 @@ class HPXMLtoOpenStudioEnclosureTest < MiniTest::Test
|
|
746
708
|
end
|
747
709
|
end
|
748
710
|
|
711
|
+
def test_collapse_surfaces
|
712
|
+
def split_surfaces(surfaces, should_collapse_surfaces)
|
713
|
+
surf_class = surfaces[0].class
|
714
|
+
for n in 1..surfaces.size
|
715
|
+
surfaces[n - 1].area /= 9.0
|
716
|
+
surfaces[n - 1].exposed_perimeter /= 9.0 if surf_class == HPXML::Slab
|
717
|
+
for i in 2..9
|
718
|
+
surfaces << surfaces[n - 1].dup
|
719
|
+
surfaces[-1].id += "_#{i}"
|
720
|
+
next if should_collapse_surfaces
|
721
|
+
|
722
|
+
# Change a property to a unique value so that it won't collapse
|
723
|
+
# with other properties of the same surface type.
|
724
|
+
if [HPXML::Roof, HPXML::Wall, HPXML::RimJoist, HPXML::Floor].include? surf_class
|
725
|
+
surfaces[-1].insulation_assembly_r_value += 0.01 * i
|
726
|
+
elsif [HPXML::FoundationWall].include? surf_class
|
727
|
+
surfaces[-1].insulation_exterior_r_value += 0.01 * i
|
728
|
+
elsif [HPXML::Slab].include? surf_class
|
729
|
+
if i < 4
|
730
|
+
surfaces[-1].perimeter_insulation_depth += 0.01 * i
|
731
|
+
else
|
732
|
+
surfaces[-1].perimeter_insulation_r_value += 0.01 * i
|
733
|
+
end
|
734
|
+
elsif [HPXML::Window, HPXML::Skylight].include? surf_class
|
735
|
+
if i < 3
|
736
|
+
surfaces[-1].ufactor += 0.01 * i
|
737
|
+
elsif i < 6
|
738
|
+
surfaces[-1].interior_shading_factor_summer -= 0.02 * i
|
739
|
+
else
|
740
|
+
surfaces[-1].interior_shading_factor_winter -= 0.01 * i
|
741
|
+
if surf_class == HPXML::Window
|
742
|
+
surfaces[-1].fraction_operable = 1.0 - surfaces[-1].fraction_operable
|
743
|
+
end
|
744
|
+
end
|
745
|
+
elsif [HPXML::Door].include? surf_class
|
746
|
+
surfaces[-1].r_value += 0.01 * i
|
747
|
+
else
|
748
|
+
fail 'Unexpected surface type.'
|
749
|
+
end
|
750
|
+
end
|
751
|
+
end
|
752
|
+
surfaces << surfaces[-1].dup
|
753
|
+
surfaces[-1].id += '_tiny'
|
754
|
+
surfaces[-1].area = 0.05
|
755
|
+
surfaces[-1].exposed_perimeter = 0.05 if surf_class == HPXML::Slab
|
756
|
+
end
|
757
|
+
|
758
|
+
def get_num_surfaces_by_type(hpxml)
|
759
|
+
return { roofs: hpxml.roofs.size,
|
760
|
+
walls: hpxml.walls.size,
|
761
|
+
rim_joists: hpxml.rim_joists.size,
|
762
|
+
foundation_walls: hpxml.foundation_walls.size,
|
763
|
+
floors: hpxml.floors.size,
|
764
|
+
slabs: hpxml.slabs.size,
|
765
|
+
windows: hpxml.windows.size,
|
766
|
+
skylights: hpxml.skylights.size,
|
767
|
+
doors: hpxml.doors.size }
|
768
|
+
end
|
769
|
+
|
770
|
+
[true, false].each do |should_collapse_surfaces|
|
771
|
+
hpxml = _create_hpxml('base-enclosure-skylights.xml')
|
772
|
+
|
773
|
+
orig_num_surfaces_by_type = get_num_surfaces_by_type(hpxml)
|
774
|
+
|
775
|
+
split_surfaces(hpxml.roofs, should_collapse_surfaces)
|
776
|
+
split_surfaces(hpxml.rim_joists, should_collapse_surfaces)
|
777
|
+
split_surfaces(hpxml.walls, should_collapse_surfaces)
|
778
|
+
split_surfaces(hpxml.foundation_walls, should_collapse_surfaces)
|
779
|
+
split_surfaces(hpxml.floors, should_collapse_surfaces)
|
780
|
+
split_surfaces(hpxml.slabs, should_collapse_surfaces)
|
781
|
+
split_surfaces(hpxml.windows, should_collapse_surfaces)
|
782
|
+
split_surfaces(hpxml.skylights, should_collapse_surfaces)
|
783
|
+
split_surfaces(hpxml.doors, should_collapse_surfaces)
|
784
|
+
|
785
|
+
split_num_surfaces_by_type = get_num_surfaces_by_type(hpxml)
|
786
|
+
hpxml.collapse_enclosure_surfaces()
|
787
|
+
final_num_surfaces_by_type = get_num_surfaces_by_type(hpxml)
|
788
|
+
|
789
|
+
for surf_type in orig_num_surfaces_by_type.keys
|
790
|
+
if should_collapse_surfaces
|
791
|
+
assert_equal(orig_num_surfaces_by_type[surf_type], final_num_surfaces_by_type[surf_type])
|
792
|
+
else
|
793
|
+
assert_equal(split_num_surfaces_by_type[surf_type] - 1, final_num_surfaces_by_type[surf_type])
|
794
|
+
end
|
795
|
+
end
|
796
|
+
end
|
797
|
+
end
|
798
|
+
|
749
799
|
def test_aspect_ratios
|
750
800
|
# Test single-family attached
|
751
|
-
hpxml = _create_hpxml('base-bldgtype-
|
752
|
-
wall_outside = hpxml.walls.
|
753
|
-
wall_other_housing_unit = hpxml.walls.
|
801
|
+
hpxml = _create_hpxml('base-bldgtype-attached.xml')
|
802
|
+
wall_outside = hpxml.walls.find { |w| w.exterior_adjacent_to == HPXML::LocationOutside && w.interior_adjacent_to == HPXML::LocationLivingSpace }
|
803
|
+
wall_other_housing_unit = hpxml.walls.find { |w| w.exterior_adjacent_to == HPXML::LocationOtherHousingUnit && w.interior_adjacent_to == HPXML::LocationLivingSpace }
|
754
804
|
|
755
805
|
wall_height = hpxml.building_construction.average_ceiling_height
|
756
806
|
left_right_wall_length = wall_other_housing_unit.area / wall_height
|
@@ -759,8 +809,8 @@ class HPXMLtoOpenStudioEnclosureTest < MiniTest::Test
|
|
759
809
|
|
760
810
|
# Test multifamily
|
761
811
|
hpxml = _create_hpxml('base-bldgtype-multifamily.xml')
|
762
|
-
wall_outside = hpxml.walls.
|
763
|
-
wall_other_housing_unit = hpxml.walls.
|
812
|
+
wall_outside = hpxml.walls.find { |w| w.exterior_adjacent_to == HPXML::LocationOutside && w.interior_adjacent_to == HPXML::LocationLivingSpace }
|
813
|
+
wall_other_housing_unit = hpxml.walls.find { |w| w.exterior_adjacent_to == HPXML::LocationOtherHousingUnit && w.interior_adjacent_to == HPXML::LocationLivingSpace }
|
764
814
|
|
765
815
|
wall_height = hpxml.building_construction.average_ceiling_height
|
766
816
|
left_right_wall_length = wall_other_housing_unit.area / wall_height
|
@@ -30,10 +30,10 @@ class HPXMLtoOpenStudioGeneratorTest < MiniTest::Test
|
|
30
30
|
|
31
31
|
# Check object
|
32
32
|
assert_equal(EPlus.fuel_type(hpxml_generator.fuel_type), generator.fuelType)
|
33
|
-
assert_in_epsilon(
|
34
|
-
assert_in_epsilon(
|
35
|
-
assert_in_epsilon(
|
36
|
-
assert_in_epsilon(0.
|
33
|
+
assert_in_epsilon(137.0, generator.referenceElectricalPowerOutput, 0.01)
|
34
|
+
assert_in_epsilon(137.0, generator.minimumFullLoadElectricalPowerOutput, 0.01)
|
35
|
+
assert_in_epsilon(137.0, generator.maximumFullLoadElectricalPowerOutput, 0.01)
|
36
|
+
assert_in_epsilon(0.48, generator.referenceElectricalEfficiencyUsingLowerHeatingValue, 0.01)
|
37
37
|
assert_equal(generator.fuelHigherHeatingValue, generator.fuelLowerHeatingValue)
|
38
38
|
assert_equal(0, generator.standbyPower)
|
39
39
|
assert_equal(0, generator.ancillaryPower)
|
@@ -50,10 +50,10 @@ class HPXMLtoOpenStudioGeneratorTest < MiniTest::Test
|
|
50
50
|
|
51
51
|
# Check object
|
52
52
|
assert_equal(EPlus.fuel_type(hpxml_generator.fuel_type), generator.fuelType)
|
53
|
-
assert_in_epsilon(
|
54
|
-
assert_in_epsilon(
|
55
|
-
assert_in_epsilon(
|
56
|
-
assert_in_epsilon(0.
|
53
|
+
assert_in_epsilon(228.3, generator.referenceElectricalPowerOutput, 0.01)
|
54
|
+
assert_in_epsilon(228.3, generator.minimumFullLoadElectricalPowerOutput, 0.01)
|
55
|
+
assert_in_epsilon(228.3, generator.maximumFullLoadElectricalPowerOutput, 0.01)
|
56
|
+
assert_in_epsilon(0.48, generator.referenceElectricalEfficiencyUsingLowerHeatingValue, 0.01)
|
57
57
|
assert_equal(generator.fuelHigherHeatingValue, generator.fuelLowerHeatingValue)
|
58
58
|
assert_equal(0, generator.standbyPower)
|
59
59
|
assert_equal(0, generator.ancillaryPower)
|
data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_hotwater_appliance.rb
CHANGED
@@ -961,7 +961,7 @@ class HPXMLtoOpenStudioHotWaterApplianceTest < MiniTest::Test
|
|
961
961
|
|
962
962
|
def test_operational
|
963
963
|
args_hash = {}
|
964
|
-
args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-
|
964
|
+
args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-residents-1.xml'))
|
965
965
|
model, _hpxml = _test_measure(args_hash)
|
966
966
|
|
967
967
|
# water use equipment peak flows
|
@@ -479,19 +479,45 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
|
|
479
479
|
end
|
480
480
|
end
|
481
481
|
|
482
|
-
def
|
483
|
-
|
484
|
-
|
485
|
-
|
482
|
+
def test_heat_pump_temperatures
|
483
|
+
['base-hvac-air-to-air-heat-pump-1-speed.xml',
|
484
|
+
'base-hvac-air-to-air-heat-pump-1-speed-lockout-temperatures.xml',
|
485
|
+
'base-hvac-air-to-air-heat-pump-var-speed-backup-boiler.xml',
|
486
|
+
'base-hvac-dual-fuel-air-to-air-heat-pump-1-speed.xml',
|
487
|
+
'base-hvac-mini-split-heat-pump-ductless.xml',
|
488
|
+
'base-hvac-mini-split-heat-pump-ductless-backup-baseboard.xml'].each do |hpxml_name|
|
489
|
+
args_hash = {}
|
490
|
+
args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, hpxml_name))
|
491
|
+
model, hpxml = _test_measure(args_hash)
|
486
492
|
|
487
|
-
|
488
|
-
|
489
|
-
|
493
|
+
# Get HPXML values
|
494
|
+
heat_pump = hpxml.heat_pumps[0]
|
495
|
+
if not heat_pump.backup_heating_switchover_temp.nil?
|
496
|
+
backup_lockout_temp = UnitConversions.convert(heat_pump.backup_heating_switchover_temp, 'F', 'C')
|
497
|
+
compressor_lockout_temp = UnitConversions.convert(heat_pump.backup_heating_switchover_temp, 'F', 'C')
|
498
|
+
else
|
499
|
+
if not heat_pump.backup_heating_lockout_temp.nil?
|
500
|
+
backup_lockout_temp = UnitConversions.convert(heat_pump.backup_heating_lockout_temp, 'F', 'C')
|
501
|
+
end
|
502
|
+
if not heat_pump.compressor_lockout_temp.nil?
|
503
|
+
compressor_lockout_temp = UnitConversions.convert(heat_pump.compressor_lockout_temp, 'F', 'C')
|
504
|
+
end
|
505
|
+
end
|
490
506
|
|
491
|
-
|
492
|
-
|
493
|
-
|
494
|
-
|
507
|
+
# Check unitary system
|
508
|
+
assert_equal(1, model.getAirLoopHVACUnitarySystems.size)
|
509
|
+
unitary_system = model.getAirLoopHVACUnitarySystems[0]
|
510
|
+
if not backup_lockout_temp.nil?
|
511
|
+
assert_in_delta(backup_lockout_temp, unitary_system.maximumOutdoorDryBulbTemperatureforSupplementalHeaterOperation, 0.01)
|
512
|
+
end
|
513
|
+
|
514
|
+
# Check coil
|
515
|
+
assert_equal(1, model.getCoilHeatingDXSingleSpeeds.size + model.getCoilHeatingDXMultiSpeeds.size)
|
516
|
+
if not compressor_lockout_temp.nil?
|
517
|
+
heating_coil = model.getCoilHeatingDXSingleSpeeds.size > 0 ? model.getCoilHeatingDXSingleSpeeds[0] : model.getCoilHeatingDXMultiSpeeds[0]
|
518
|
+
assert_in_delta(compressor_lockout_temp, heating_coil.minimumOutdoorDryBulbTemperatureforCompressorOperation, 0.01)
|
519
|
+
end
|
520
|
+
end
|
495
521
|
end
|
496
522
|
|
497
523
|
def test_air_to_air_heat_pump_2_speed
|
@@ -1105,6 +1131,20 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
|
|
1105
1131
|
assert_includes(end_dates, end_date)
|
1106
1132
|
end
|
1107
1133
|
|
1134
|
+
def test_crankcase_heater_watts
|
1135
|
+
args_hash = {}
|
1136
|
+
args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-crankcase-heater-40w.xml'))
|
1137
|
+
model, hpxml = _test_measure(args_hash)
|
1138
|
+
|
1139
|
+
# Get HPXML values
|
1140
|
+
cooling_system = hpxml.cooling_systems[0]
|
1141
|
+
crankcase_heater_watts = cooling_system.crankcase_heater_watts
|
1142
|
+
|
1143
|
+
# Check cooling coil
|
1144
|
+
clg_coil = model.getCoilCoolingDXSingleSpeeds[0]
|
1145
|
+
assert_in_epsilon(crankcase_heater_watts, clg_coil.crankcaseHeaterCapacity, 0.01)
|
1146
|
+
end
|
1147
|
+
|
1108
1148
|
def _test_measure(args_hash)
|
1109
1149
|
# create an instance of the measure
|
1110
1150
|
measure = HPXMLtoOpenStudio.new
|