openstudio-standards 0.8.3 → 0.8.4
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- checksums.yaml +4 -4
- data/lib/openstudio-standards/btap/costing/README.md +502 -0
- data/lib/openstudio-standards/btap/costing/btap_costing.rb +473 -0
- data/lib/openstudio-standards/btap/costing/btap_measure_helper.rb +359 -0
- data/lib/openstudio-standards/btap/costing/btap_workflow.rb +117 -0
- data/lib/openstudio-standards/btap/costing/common_paths.rb +78 -0
- data/lib/openstudio-standards/btap/costing/common_resources/ConstructionProperties.csv +52 -0
- data/lib/openstudio-standards/btap/costing/common_resources/Constructions.csv +37 -0
- data/lib/openstudio-standards/btap/costing/common_resources/construction_sets.csv +1270 -0
- data/lib/openstudio-standards/btap/costing/common_resources/constructions_glazing.csv +61 -0
- data/lib/openstudio-standards/btap/costing/common_resources/constructions_opaque.csv +2256 -0
- data/lib/openstudio-standards/btap/costing/common_resources/costs.csv +1904 -0
- data/lib/openstudio-standards/btap/costing/common_resources/costs_local_factors.csv +2315 -0
- data/lib/openstudio-standards/btap/costing/common_resources/hvac_vent_ahu.csv +925 -0
- data/lib/openstudio-standards/btap/costing/common_resources/lighting.csv +364 -0
- data/lib/openstudio-standards/btap/costing/common_resources/lighting_sets.csv +2667 -0
- data/lib/openstudio-standards/btap/costing/common_resources/locations.csv +75 -0
- data/lib/openstudio-standards/btap/costing/common_resources/materials_glazing.csv +35 -0
- data/lib/openstudio-standards/btap/costing/common_resources/materials_hvac.csv +1699 -0
- data/lib/openstudio-standards/btap/costing/common_resources/materials_lighting.csv +267 -0
- data/lib/openstudio-standards/btap/costing/common_resources/materials_opaque.csv +164 -0
- data/lib/openstudio-standards/btap/costing/copy_test_results_files_to_expected_results.rb +11 -0
- data/lib/openstudio-standards/btap/costing/cost_building_from_file.rb +136 -0
- data/lib/openstudio-standards/btap/costing/costing_database_wrapper.rb +177 -0
- data/lib/openstudio-standards/btap/costing/daylighting_sensor_control_costing.rb +353 -0
- data/lib/openstudio-standards/btap/costing/dcv_costing.rb +314 -0
- data/lib/openstudio-standards/btap/costing/dummy.epw +8768 -0
- data/lib/openstudio-standards/btap/costing/dummy.osm +5320 -0
- data/lib/openstudio-standards/btap/costing/envelope_costing.rb +284 -0
- data/lib/openstudio-standards/btap/costing/heating_cooling_costing.rb +2584 -0
- data/lib/openstudio-standards/btap/costing/led_lighting_costing.rb +155 -0
- data/lib/openstudio-standards/btap/costing/lighting_costing.rb +209 -0
- data/lib/openstudio-standards/btap/costing/mech_sizing.json +502 -0
- data/lib/openstudio-standards/btap/costing/neb_end_use_prices.csv +42 -0
- data/lib/openstudio-standards/btap/costing/necb_2011_spacetype_info.csv +225 -0
- data/lib/openstudio-standards/btap/costing/necb_reference_runs.csv +28705 -0
- data/lib/openstudio-standards/btap/costing/nv_costing.rb +547 -0
- data/lib/openstudio-standards/btap/costing/parallel_tests.rb +92 -0
- data/lib/openstudio-standards/btap/costing/pv_ground_costing.rb +687 -0
- data/lib/openstudio-standards/btap/costing/shw_costing.rb +705 -0
- data/lib/openstudio-standards/btap/costing/test_list.txt +17 -0
- data/lib/openstudio-standards/btap/costing/test_run_all_test_locally.rb +26 -0
- data/lib/openstudio-standards/btap/costing/test_run_costing_tests.rb +80 -0
- data/lib/openstudio-standards/btap/costing/ventilation_costing.rb +2616 -0
- data/lib/openstudio-standards/constructions/modify.rb +2 -1
- data/lib/openstudio-standards/standards/Standards.Model.rb +39 -9
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Model.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/ashrae_90_1_prm.UserData.rb +6 -1
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +2 -27
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_3_and_8_single_speed.rb +68 -27
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_4.rb +64 -25
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_6.rb +9 -14
- data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +46 -20
- data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +635 -248
- data/lib/openstudio-standards/standards/necb/NECB2011/data/constants.json +43 -7
- data/lib/openstudio-standards/standards/necb/NECB2011/data/fuel_type_sets.json +7 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/HighriseApartmentMult.osm +14272 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/necb_2015_table_c1.json +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +437 -437
- data/lib/openstudio-standards/standards/necb/NECB2011/data/systems.json +516 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/systems_including_sys5.json +588 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_namer.rb +489 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +16 -6
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_2_and_5.rb +48 -5
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_multi_speed.rb +2 -2
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_single_speed.rb +35 -27
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_4.rb +34 -23
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +8 -6
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +42 -13
- data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +214 -25
- data/lib/openstudio-standards/standards/necb/NECB2011/system_fuels.rb +61 -1
- data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +636 -636
- data/lib/openstudio-standards/standards/necb/NECB2015/data/unitary_acs.json +38 -38
- data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +15 -6
- data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +636 -636
- data/lib/openstudio-standards/standards/necb/NECB2020/data/chillers.json +71 -71
- data/lib/openstudio-standards/standards/necb/README.md +343 -0
- data/lib/openstudio-standards/standards/necb/common/btap_data.rb +190 -28
- data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +14 -5
- data/lib/openstudio-standards/standards/necb/common/eccc_electric_grid_intensity_20250311.csv +14 -0
- data/lib/openstudio-standards/standards/necb/common/nir_gas_grid_intensity_20250311.csv +14 -0
- data/lib/openstudio-standards/standards/necb/common/system_types.yaml +0 -0
- data/lib/openstudio-standards/utilities/logging.rb +18 -14
- data/lib/openstudio-standards/version.rb +1 -1
- data/lib/openstudio-standards/weather/modify.rb +2 -2
- data/lib/openstudio-standards.rb +12 -0
- metadata +53 -2
@@ -0,0 +1,2256 @@
|
|
1
|
+
construction_opaque_id,surface_type,construction_type_name,author,old_type_code,intended_surface_type,standards_construction_type,type_index,climate_zone,rsi_k_m2_per_w,description,material_opaque_id_layers,material_desciptions,Code
|
2
|
+
1,EXPFLOOR,BTAP-ExteriorFloor-SteelFramed-1,BTAP,1,ExteriorFloor,SteelFramed,1,Zone 4,4.41,"Steel Flooring with Metal finish, 100 PSF load","117,145,118,3,99,6,119","Floor system, light gauge (14 ga.) galvanized steel, ""C"" type joists, 10"" deep, 24"" spacing, 15' span, 116 PSF total load
|
3
|
+
Installation of 14 gauge steel floor joist to beams/headers
|
4
|
+
3/4"" thick CDX plywood subfloor, pneumatic nailed
|
5
|
+
polyethylene 4 ml vapour barrier
|
6
|
+
9.5"" thick fibreglass, kraft coated ceiling insulation, 15"" wide blanket (RSI 5.28)
|
7
|
+
weather barrier, spunbonded polyethylene
|
8
|
+
Steel siding, bevelled with vinyl finish, 10"" width
|
9
|
+
",NECB_2011
|
10
|
+
2,EXPFLOOR,BTAP-ExteriorFloor-SteelFramed-1,BTAP,1,ExteriorFloor,SteelFramed,1,Zone 5,5.46,"Steel Flooring with Metal finish, 100 PSF load","117,145,118,3,99,56,6,119","Floor system, light gauge (14 ga.) galvanized steel, ""C"" type joists, 10"" deep, 24"" spacing, 15' span, 116 PSF total load
|
11
|
+
Installation of 14 gauge steel floor joist to beams/headers
|
12
|
+
3/4"" thick CDX plywood subfloor, pneumatic nailed
|
13
|
+
polyethylene 4 ml vapour barrier
|
14
|
+
9.5"" thick fibreglass, kraft coated ceiling insulation, 15"" wide blanket (RSI 5.28)
|
15
|
+
Isoboard, 1"" thick, RSI .98
|
16
|
+
weather barrier, spunbonded polyethylene
|
17
|
+
Steel siding, bevelled with vinyl finish, 10"" width
|
18
|
+
",NECB_2011
|
19
|
+
3,EXPFLOOR,BTAP-ExteriorFloor-SteelFramed-1,BTAP,1,ExteriorFloor,SteelFramed,1,Zone 6,5.46,"Steel Flooring with Metal finish, 100 PSF load","117,145,118,3,99,56,6,119","Floor system, light gauge (14 ga.) galvanized steel, ""C"" type joists, 10"" deep, 24"" spacing, 15' span, 116 PSF total load
|
20
|
+
Installation of 14 gauge steel floor joist to beams/headers
|
21
|
+
3/4"" thick CDX plywood subfloor, pneumatic nailed
|
22
|
+
polyethylene 4 ml vapour barrier
|
23
|
+
9.5"" thick fibreglass, kraft coated ceiling insulation, 15"" wide blanket (RSI 5.28)
|
24
|
+
Isoboard, 1"" thick, RSI .98
|
25
|
+
weather barrier, spunbonded polyethylene
|
26
|
+
Steel siding, bevelled with vinyl finish, 10"" width
|
27
|
+
",NECB_2011
|
28
|
+
4,EXPFLOOR,BTAP-ExteriorFloor-SteelFramed-1,BTAP,1,ExteriorFloor,SteelFramed,1,Zone 7A,6.17,"Steel Flooring with Metal finish, 100 PSF load","117,145,118,3,99,67,6,119","Floor system, light gauge (14 ga.) galvanized steel, ""C"" type joists, 10"" deep, 24"" spacing, 15' span, 116 PSF total load
|
29
|
+
Installation of 14 gauge steel floor joist to beams/headers
|
30
|
+
3/4"" thick CDX plywood subfloor, pneumatic nailed
|
31
|
+
polyethylene 4 ml vapour barrier
|
32
|
+
9.5"" thick fibreglass, kraft coated ceiling insulation, 15"" wide blanket (RSI 5.28)
|
33
|
+
Isoboard sheathing, 2"" thick RSI 1.93
|
34
|
+
weather barrier, spunbonded polyethylene
|
35
|
+
Steel siding, bevelled with vinyl finish, 10"" width
|
36
|
+
",NECB_2011
|
37
|
+
5,EXPFLOOR,BTAP-ExteriorFloor-SteelFramed-1,BTAP,1,ExteriorFloor,SteelFramed,1,Zone 7B,6.17,"Steel Flooring with Metal finish, 100 PSF load","117,145,118,3,99,67,6,119","Floor system, light gauge (14 ga.) galvanized steel, ""C"" type joists, 10"" deep, 24"" spacing, 15' span, 116 PSF total load
|
38
|
+
Installation of 14 gauge steel floor joist to beams/headers
|
39
|
+
3/4"" thick CDX plywood subfloor, pneumatic nailed
|
40
|
+
polyethylene 4 ml vapour barrier
|
41
|
+
9.5"" thick fibreglass, kraft coated ceiling insulation, 15"" wide blanket (RSI 5.28)
|
42
|
+
Isoboard sheathing, 2"" thick RSI 1.93
|
43
|
+
weather barrier, spunbonded polyethylene
|
44
|
+
Steel siding, bevelled with vinyl finish, 10"" width
|
45
|
+
",NECB_2011
|
46
|
+
6,EXPFLOOR,BTAP-ExteriorFloor-SteelFramed-1,BTAP,1,ExteriorFloor,SteelFramed,1,Zone 8,7.04,"Steel Flooring with Metal finish, 100 PSF load","117,145,118,3,163,67,6,119","Floor system, light gauge (14 ga.) galvanized steel, ""C"" type joists, 10"" deep, 24"" spacing, 15' span, 116 PSF total load
|
47
|
+
Installation of 14 gauge steel floor joist to beams/headers
|
48
|
+
3/4"" thick CDX plywood subfloor, pneumatic nailed
|
49
|
+
polyethylene 4 ml vapour barrier
|
50
|
+
Polyurethane Foam 4.5"" thick, RSI5.72
|
51
|
+
Isoboard sheathing, 2"" thick RSI 1.93
|
52
|
+
weather barrier, spunbonded polyethylene
|
53
|
+
Steel siding, bevelled with vinyl finish, 10"" width
|
54
|
+
",NECB_2011
|
55
|
+
7,EXPFLOOR,BTAP-ExteriorFloor-WoodFramed-1,BTAP,2,ExteriorFloor,WoodFramed,1,Zone 4,4.41,"Wood Flooring with Metal finish, 100 PSF load","120,118,3,99,6,119","Floor system, 2""x10"" joists, 24"" spacing, 116 PSF total load
|
56
|
+
3/4"" thick CDX plywood subfloor, pneumatic nailed
|
57
|
+
polyethylene 4 ml vapour barrier
|
58
|
+
9.5"" thick fibreglass, kraft coated ceiling insulation, 15"" wide blanket (RSI 5.28)
|
59
|
+
weather barrier, spunbonded polyethylene
|
60
|
+
Steel siding, bevelled with vinyl finish, 10"" width
|
61
|
+
",NECB_2011
|
62
|
+
8,EXPFLOOR,BTAP-ExteriorFloor-WoodFramed-1,BTAP,2,ExteriorFloor,WoodFramed,1,Zone 5,5.46,"Wood Flooring with Metal finish, 100 PSF load","120,118,3,99,6,119","Floor system, 2""x10"" joists, 24"" spacing, 116 PSF total load
|
63
|
+
3/4"" thick CDX plywood subfloor, pneumatic nailed
|
64
|
+
polyethylene 4 ml vapour barrier
|
65
|
+
9.5"" thick fibreglass, kraft coated ceiling insulation, 15"" wide blanket (RSI 5.28)
|
66
|
+
weather barrier, spunbonded polyethylene
|
67
|
+
Steel siding, bevelled with vinyl finish, 10"" width
|
68
|
+
",NECB_2011
|
69
|
+
9,EXPFLOOR,BTAP-ExteriorFloor-WoodFramed-1,BTAP,2,ExteriorFloor,WoodFramed,1,Zone 6,5.46,"Wood Flooring with Metal finish, 100 PSF load","120,118,3,99,6,119","Floor system, 2""x10"" joists, 24"" spacing, 116 PSF total load
|
70
|
+
3/4"" thick CDX plywood subfloor, pneumatic nailed
|
71
|
+
polyethylene 4 ml vapour barrier
|
72
|
+
9.5"" thick fibreglass, kraft coated ceiling insulation, 15"" wide blanket (RSI 5.28)
|
73
|
+
weather barrier, spunbonded polyethylene
|
74
|
+
Steel siding, bevelled with vinyl finish, 10"" width
|
75
|
+
",NECB_2011
|
76
|
+
10,EXPFLOOR,BTAP-ExteriorFloor-WoodFramed-1,BTAP,2,ExteriorFloor,WoodFramed,1,Zone 7A,6.17,"Wood Flooring with Metal finish, 100 PSF load","120,118,3,99,54,6,119","Floor system, 2""x10"" joists, 24"" spacing, 116 PSF total load
|
77
|
+
3/4"" thick CDX plywood subfloor, pneumatic nailed
|
78
|
+
polyethylene 4 ml vapour barrier
|
79
|
+
9.5"" thick fibreglass, kraft coated ceiling insulation, 15"" wide blanket (RSI 5.28)
|
80
|
+
0.5"" Isoboard, 4 x 8 sheet, foil faced (RSI 0.48)
|
81
|
+
weather barrier, spunbonded polyethylene
|
82
|
+
Steel siding, bevelled with vinyl finish, 10"" width
|
83
|
+
",NECB_2011
|
84
|
+
11,EXPFLOOR,BTAP-ExteriorFloor-WoodFramed-1,BTAP,2,ExteriorFloor,WoodFramed,1,Zone 7B,6.17,"Wood Flooring with Metal finish, 100 PSF load","120,118,3,99,54,6,119","Floor system, 2""x10"" joists, 24"" spacing, 116 PSF total load
|
85
|
+
3/4"" thick CDX plywood subfloor, pneumatic nailed
|
86
|
+
polyethylene 4 ml vapour barrier
|
87
|
+
9.5"" thick fibreglass, kraft coated ceiling insulation, 15"" wide blanket (RSI 5.28)
|
88
|
+
0.5"" Isoboard, 4 x 8 sheet, foil faced (RSI 0.48)
|
89
|
+
weather barrier, spunbonded polyethylene
|
90
|
+
Steel siding, bevelled with vinyl finish, 10"" width
|
91
|
+
",NECB_2011
|
92
|
+
12,EXPFLOOR,BTAP-ExteriorFloor-WoodFramed-1,BTAP,2,ExteriorFloor,WoodFramed,1,Zone 8,7.04,"Wood Flooring with Metal finish, 100 PSF load","120,118,3,68,54,6,119","Floor system, 2""x10"" joists, 24"" spacing, 116 PSF total load
|
93
|
+
3/4"" thick CDX plywood subfloor, pneumatic nailed
|
94
|
+
polyethylene 4 ml vapour barrier
|
95
|
+
Polyurethane Foam 4.5"" thick, RSI 5.15 modified to 5.5"" foaming RSI 6.18
|
96
|
+
0.5"" Isoboard, 4 x 8 sheet, foil faced (RSI 0.48)
|
97
|
+
weather barrier, spunbonded polyethylene
|
98
|
+
Steel siding, bevelled with vinyl finish, 10"" width
|
99
|
+
",NECB_2011
|
100
|
+
13,ROOF,BTAP-ExteriorRoof-IEAD-1,BTAP,1,ExteriorRoof,IEAD,1,Zone 4,4.41,Built-up Deck Roof on a Nailable Deck,"87,97,57,80,90","asphalt flood coat, gravel base coated glass-fibre sheet and 3 plies glass fibre felt (type IV) mopped on nailable deck
|
101
|
+
Plywood underlayment 0.75' thick
|
102
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
103
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
104
|
+
Spruce Wood decking, 2 "" thick
|
105
|
+
",NECB_2011
|
106
|
+
14,ROOF,BTAP-ExteriorRoof-IEAD-1,BTAP,1,ExteriorRoof,IEAD,1,Zone 5,5.46,Built-up Deck Roof on a Nailable Deck,"87,97,134,134,90","asphalt flood coat, gravel base coated glass-fibre sheet and 3 plies glass fibre felt (type IV) mopped on nailable deck
|
107
|
+
Plywood underlayment 0.75' thick
|
108
|
+
XPS, 3"" 2.64
|
109
|
+
XPS, 3"" 2.64
|
110
|
+
Spruce Wood decking, 2 "" thick
|
111
|
+
",NECB_2011
|
112
|
+
15,ROOF,BTAP-ExteriorRoof-IEAD-1,BTAP,1,ExteriorRoof,IEAD,1,Zone 6,5.46,Built-up Deck Roof on a Nailable Deck,"87,97,134,134,90","asphalt flood coat, gravel base coated glass-fibre sheet and 3 plies glass fibre felt (type IV) mopped on nailable deck
|
113
|
+
Plywood underlayment 0.75' thick
|
114
|
+
XPS, 3"" 2.64
|
115
|
+
XPS, 3"" 2.64
|
116
|
+
Spruce Wood decking, 2 "" thick
|
117
|
+
",NECB_2011
|
118
|
+
16,ROOF,BTAP-ExteriorRoof-IEAD-1,BTAP,1,ExteriorRoof,IEAD,1,Zone 7A,6.17,Built-up Deck Roof on a Nailable Deck,"87,97,80,80,150,90","asphalt flood coat, gravel base coated glass-fibre sheet and 3 plies glass fibre felt (type IV) mopped on nailable deck
|
119
|
+
Plywood underlayment 0.75' thick
|
120
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
121
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
122
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
123
|
+
Spruce Wood decking, 2 "" thick
|
124
|
+
",NECB_2011
|
125
|
+
17,ROOF,BTAP-ExteriorRoof-IEAD-1,BTAP,1,ExteriorRoof,IEAD,1,Zone 7B,6.17,Built-up Deck Roof on a Nailable Deck,"87,97,80,80,150,90","asphalt flood coat, gravel base coated glass-fibre sheet and 3 plies glass fibre felt (type IV) mopped on nailable deck
|
126
|
+
Plywood underlayment 0.75' thick
|
127
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
128
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
129
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
130
|
+
Spruce Wood decking, 2 "" thick
|
131
|
+
",NECB_2011
|
132
|
+
18,ROOF,BTAP-ExteriorRoof-IEAD-1,BTAP,1,ExteriorRoof,IEAD,1,Zone 8,7.04,Built-up Deck Roof on a Nailable Deck,"87,97,80,80,57,90","asphalt flood coat, gravel base coated glass-fibre sheet and 3 plies glass fibre felt (type IV) mopped on nailable deck
|
133
|
+
Plywood underlayment 0.75' thick
|
134
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
135
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
136
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
137
|
+
Spruce Wood decking, 2 "" thick
|
138
|
+
",NECB_2011
|
139
|
+
19,ROOF,BTAP-ExteriorRoof-IEAD-2,BTAP,2,ExteriorRoof,IEAD,2,Zone 4,4.41,Built-up Deck Roof on a Nailable Deck,"87,97,57,80,93","asphalt flood coat, gravel base coated glass-fibre sheet and 3 plies glass fibre felt (type IV) mopped on nailable deck
|
140
|
+
Plywood underlayment 0.75' thick
|
141
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
142
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
143
|
+
Steel decking, open type galvanized, 1.5"" rib depth, 18 gauge
|
144
|
+
",NECB_2011
|
145
|
+
20,ROOF,BTAP-ExteriorRoof-IEAD-2,BTAP,2,ExteriorRoof,IEAD,2,Zone 5,5.46,Built-up Deck Roof on a Steel Deck,"87,97,134,134,93","asphalt flood coat, gravel base coated glass-fibre sheet and 3 plies glass fibre felt (type IV) mopped on nailable deck
|
146
|
+
Plywood underlayment 0.75' thick
|
147
|
+
XPS, 3"" 2.64
|
148
|
+
XPS, 3"" 2.64
|
149
|
+
Steel decking, open type galvanized, 1.5"" rib depth, 18 gauge
|
150
|
+
",NECB_2011
|
151
|
+
21,ROOF,BTAP-ExteriorRoof-IEAD-2,BTAP,2,ExteriorRoof,IEAD,2,Zone 6,5.46,Built-up Deck Roof on a Steel Deck,"87,97,134,134,93","asphalt flood coat, gravel base coated glass-fibre sheet and 3 plies glass fibre felt (type IV) mopped on nailable deck
|
152
|
+
Plywood underlayment 0.75' thick
|
153
|
+
XPS, 3"" 2.64
|
154
|
+
XPS, 3"" 2.64
|
155
|
+
Steel decking, open type galvanized, 1.5"" rib depth, 18 gauge
|
156
|
+
",NECB_2011
|
157
|
+
22,ROOF,BTAP-ExteriorRoof-IEAD-2,BTAP,2,ExteriorRoof,IEAD,2,Zone 7A,6.17,Built-up Deck Roof on a Nailable Deck,"87,97,80,80,150,93","asphalt flood coat, gravel base coated glass-fibre sheet and 3 plies glass fibre felt (type IV) mopped on nailable deck
|
158
|
+
Plywood underlayment 0.75' thick
|
159
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
160
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
161
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
162
|
+
Steel decking, open type galvanized, 1.5"" rib depth, 18 gauge
|
163
|
+
",NECB_2011
|
164
|
+
23,ROOF,BTAP-ExteriorRoof-IEAD-2,BTAP,2,ExteriorRoof,IEAD,2,Zone 7B,6.17,Built-up Deck Roof on a Nailable Deck,"87,97,80,80,150,93","asphalt flood coat, gravel base coated glass-fibre sheet and 3 plies glass fibre felt (type IV) mopped on nailable deck
|
165
|
+
Plywood underlayment 0.75' thick
|
166
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
167
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
168
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
169
|
+
Steel decking, open type galvanized, 1.5"" rib depth, 18 gauge
|
170
|
+
",NECB_2011
|
171
|
+
24,ROOF,BTAP-ExteriorRoof-IEAD-2,BTAP,2,ExteriorRoof,IEAD,2,Zone 8,7.04,Built-up Deck Roof on a Nailable Deck,"87,97,80,80,57,93","asphalt flood coat, gravel base coated glass-fibre sheet and 3 plies glass fibre felt (type IV) mopped on nailable deck
|
172
|
+
Plywood underlayment 0.75' thick
|
173
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
174
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
175
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
176
|
+
Steel decking, open type galvanized, 1.5"" rib depth, 18 gauge
|
177
|
+
",NECB_2011
|
178
|
+
25,ROOF,BTAP-ExteriorRoof-IEAD-3,BTAP,3,ExteriorRoof,IEAD,3,Zone 4,4.41,Deck Roof with a Membrane on a Nailable Deck,"94,97,57,80,90","60 ml Single ply EPDM membrane fully adhered to underlayment, 0.4 lb/ft2 no ballast or aggregate topping
|
179
|
+
Plywood underlayment 0.75' thick
|
180
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
181
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
182
|
+
Spruce Wood decking, 2 "" thick
|
183
|
+
",NECB_2011
|
184
|
+
26,ROOF,BTAP-ExteriorRoof-IEAD-3,BTAP,3,ExteriorRoof,IEAD,3,Zone 5,5.46,Deck Roof with a Membrane on a Nailable Deck,"94,97,134,134,90","60 ml Single ply EPDM membrane fully adhered to underlayment, 0.4 lb/ft2 no ballast or aggregate topping
|
185
|
+
Plywood underlayment 0.75' thick
|
186
|
+
XPS, 3"" 2.64
|
187
|
+
XPS, 3"" 2.64
|
188
|
+
Spruce Wood decking, 2 "" thick
|
189
|
+
",NECB_2011
|
190
|
+
27,ROOF,BTAP-ExteriorRoof-IEAD-3,BTAP,3,ExteriorRoof,IEAD,3,Zone 6,5.46,Deck Roof with a Membrane on a Nailable Deck,"94,97,134,134,90","60 ml Single ply EPDM membrane fully adhered to underlayment, 0.4 lb/ft2 no ballast or aggregate topping
|
191
|
+
Plywood underlayment 0.75' thick
|
192
|
+
XPS, 3"" 2.64
|
193
|
+
XPS, 3"" 2.64
|
194
|
+
Spruce Wood decking, 2 "" thick
|
195
|
+
",NECB_2011
|
196
|
+
28,ROOF,BTAP-ExteriorRoof-IEAD-3,BTAP,3,ExteriorRoof,IEAD,3,Zone 7A,6.17,Deck Roof with a Membrane on a Nailable Deck,"94,97,80,80,150,90","60 ml Single ply EPDM membrane fully adhered to underlayment, 0.4 lb/ft2 no ballast or aggregate topping
|
197
|
+
Plywood underlayment 0.75' thick
|
198
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
199
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
200
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
201
|
+
Spruce Wood decking, 2 "" thick
|
202
|
+
",NECB_2011
|
203
|
+
29,ROOF,BTAP-ExteriorRoof-IEAD-3,BTAP,3,ExteriorRoof,IEAD,3,Zone 7B,6.17,Deck Roof with a Membrane on a Nailable Deck,"94,97,80,80,150,90","60 ml Single ply EPDM membrane fully adhered to underlayment, 0.4 lb/ft2 no ballast or aggregate topping
|
204
|
+
Plywood underlayment 0.75' thick
|
205
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
206
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
207
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
208
|
+
Spruce Wood decking, 2 "" thick
|
209
|
+
",NECB_2011
|
210
|
+
30,ROOF,BTAP-ExteriorRoof-IEAD-3,BTAP,3,ExteriorRoof,IEAD,3,Zone 8,7.04,Deck Roof with a Membrane on a Nailable Deck,"94,97,80,80,57,90","60 ml Single ply EPDM membrane fully adhered to underlayment, 0.4 lb/ft2 no ballast or aggregate topping
|
211
|
+
Plywood underlayment 0.75' thick
|
212
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
213
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
214
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
215
|
+
Spruce Wood decking, 2 "" thick
|
216
|
+
",NECB_2011
|
217
|
+
31,ROOF,BTAP-ExteriorRoof-IEAD-4,BTAP,4,ExteriorRoof,IEAD,4,Zone 4-NECB2011,4.41,Deck Roof with a Membrane on a Steel Deck,"94,88,40,40,150,93","60 ml Single ply EPDM membrane fully adhered to underlayment, 0.4 lb/ft2 no ballast or aggregate topping
|
218
|
+
plywood underlayment 0.5"" thick
|
219
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
220
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
221
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
222
|
+
Steel decking, open type galvanized, 1.5"" rib depth, 18 gauge
|
223
|
+
",NECB_2011/2017
|
224
|
+
229,ROOF,BTAP-ExteriorRoof-IEAD-4,BTAP,4,ExteriorRoof,IEAD,4,Zone 4-NECB2017,5.18,Deck Roof with a Membrane on a Steel Deck,"94,88,40,40,40,93","60 ml Single ply EPDM membrane fully adhered to underlayment, 0.4 lb/ft2 no ballast or aggregate topping
|
225
|
+
plywood underlayment 0.5"" thick
|
226
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
227
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
228
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
229
|
+
Steel decking, open type galvanized, 1.5"" rib depth, 18 gauge
|
230
|
+
",NECB_2011/2017
|
231
|
+
32,ROOF,BTAP-ExteriorRoof-IEAD-4,BTAP,4,ExteriorRoof,IEAD,4,Zone 5-NECB2011,5.46,Deck Roof with a Membrane on a Steel Deck,"94,88,40,40,40,158,93","60 ml Single ply EPDM membrane fully adhered to underlayment, 0.4 lb/ft2 no ballast or aggregate topping
|
232
|
+
plywood underlayment 0.5"" thick
|
233
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
234
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
235
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
236
|
+
XPS, 3/4"" RSI 0.501
|
237
|
+
Steel decking, open type galvanized, 1.5"" rib depth, 18 gauge
|
238
|
+
",NECB_2011/2017
|
239
|
+
34,ROOF,BTAP-ExteriorRoof-IEAD-4,BTAP,4,ExteriorRoof,IEAD,4,Zone 7A-NECB2011,6.17,Deck Roof with a Membrane on a Steel Deck,"94,88,40,40,150,40,93","60 ml Single ply EPDM membrane fully adhered to underlayment, 0.4 lb/ft2 no ballast or aggregate topping
|
240
|
+
plywood underlayment 0.5"" thick
|
241
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
242
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
243
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
244
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
245
|
+
Steel decking, open type galvanized, 1.5"" rib depth, 18 gauge
|
246
|
+
",NECB_2011/2017
|
247
|
+
230,ROOF,BTAP-ExteriorRoof-IEAD-4,BTAP,4,ExteriorRoof,IEAD,4,Zone 5-NECB2017,6.41,Deck Roof with a Membrane on a Steel Deck,"94,88,40,40,40,150,158,93","60 ml Single ply EPDM membrane fully adhered to underlayment, 0.4 lb/ft2 no ballast or aggregate topping
|
248
|
+
plywood underlayment 0.5"" thick
|
249
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
250
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
251
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
252
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
253
|
+
XPS, 3/4"" RSI 0.501
|
254
|
+
Steel decking, open type galvanized, 1.5"" rib depth, 18 gauge
|
255
|
+
",NECB_2011/2017
|
256
|
+
232,ROOF,BTAP-ExteriorRoof-IEAD-4,BTAP,4,ExteriorRoof,IEAD,4,Zone 7A-NECB2017,7.25,Deck Roof with a Membrane on a Steel Deck,"94,88,40,40,40,40,158,93","60 ml Single ply EPDM membrane fully adhered to underlayment, 0.4 lb/ft2 no ballast or aggregate topping
|
257
|
+
plywood underlayment 0.5"" thick
|
258
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
259
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
260
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
261
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
262
|
+
XPS, 3/4"" RSI 0.501
|
263
|
+
Steel decking, open type galvanized, 1.5"" rib depth, 18 gauge
|
264
|
+
",NECB_2011/2017
|
265
|
+
234,ROOF,BTAP-ExteriorRoof-IEAD-4,BTAP,4,ExteriorRoof,IEAD,4,Zone 8-NECB2017,8.26,Deck Roof with a Membrane on a Steel Deck,"94,88,40,40,40,150,40,158,93","60 ml Single ply EPDM membrane fully adhered to underlayment, 0.4 lb/ft2 no ballast or aggregate topping
|
266
|
+
plywood underlayment 0.5"" thick
|
267
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
268
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
269
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
270
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
271
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
272
|
+
XPS, 3/4"" RSI 0.501
|
273
|
+
Steel decking, open type galvanized, 1.5"" rib depth, 18 gauge
|
274
|
+
",NECB_2011/2017
|
275
|
+
37,ROOF,BTAP-ExteriorRoof-IEAD-5,BTAP,6,ExteriorRoof,IEAD,5,Zone 4,4.41,"Asphalt Shingle Roofing, ","98,96,97,57,80,97","Premium shingles, Class A, 300-385 lbs/ft2, pneumatic nailer
|
276
|
+
Asphalt felt, #15
|
277
|
+
Plywood underlayment 0.75' thick
|
278
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
279
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
280
|
+
Plywood underlayment 0.75' thick
|
281
|
+
",NECB_2011
|
282
|
+
38,ROOF,BTAP-ExteriorRoof-IEAD-5,BTAP,6,ExteriorRoof,IEAD,5,Zone 5,5.46,"Asphalt Shingle Roofing, ","98,96,97,134,134,97","Premium shingles, Class A, 300-385 lbs/ft2, pneumatic nailer
|
283
|
+
Asphalt felt, #15
|
284
|
+
Plywood underlayment 0.75' thick
|
285
|
+
XPS, 3"" 2.64
|
286
|
+
XPS, 3"" 2.64
|
287
|
+
Plywood underlayment 0.75' thick
|
288
|
+
",NECB_2011
|
289
|
+
39,ROOF,BTAP-ExteriorRoof-IEAD-5,BTAP,6,ExteriorRoof,IEAD,5,Zone 6,5.46,"Asphalt Shingle Roofing, ","98,96,97,134,134,97","Premium shingles, Class A, 300-385 lbs/ft2, pneumatic nailer
|
290
|
+
Asphalt felt, #15
|
291
|
+
Plywood underlayment 0.75' thick
|
292
|
+
XPS, 3"" 2.64
|
293
|
+
XPS, 3"" 2.64
|
294
|
+
Plywood underlayment 0.75' thick
|
295
|
+
",NECB_2011
|
296
|
+
40,ROOF,BTAP-ExteriorRoof-IEAD-5,BTAP,6,ExteriorRoof,IEAD,5,Zone 7A,6.17,"Asphalt Shingle Roofing, ","98,96,97,80,80,150,97","Premium shingles, Class A, 300-385 lbs/ft2, pneumatic nailer
|
297
|
+
Asphalt felt, #15
|
298
|
+
Plywood underlayment 0.75' thick
|
299
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
300
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
301
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
302
|
+
Plywood underlayment 0.75' thick
|
303
|
+
",NECB_2011
|
304
|
+
41,ROOF,BTAP-ExteriorRoof-IEAD-5,BTAP,6,ExteriorRoof,IEAD,5,Zone 7B,6.17,"Asphalt Shingle Roofing, ","98,96,97,80,80,150,97","Premium shingles, Class A, 300-385 lbs/ft2, pneumatic nailer
|
305
|
+
Asphalt felt, #15
|
306
|
+
Plywood underlayment 0.75' thick
|
307
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
308
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
309
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
310
|
+
Plywood underlayment 0.75' thick
|
311
|
+
",NECB_2011
|
312
|
+
42,ROOF,BTAP-ExteriorRoof-IEAD-5,BTAP,6,ExteriorRoof,IEAD,5,Zone 8,7.04,"Asphalt Shingle Roofing, ","98,96,97,80,80,57,97","Premium shingles, Class A, 300-385 lbs/ft2, pneumatic nailer
|
313
|
+
Asphalt felt, #15
|
314
|
+
Plywood underlayment 0.75' thick
|
315
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
316
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
317
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
318
|
+
Plywood underlayment 0.75' thick
|
319
|
+
",NECB_2011
|
320
|
+
43,ROOF,BTAP-ExteriorRoof-IEAD-6,BTAP,8,ExteriorRoof,IEAD,6,Zone 4,4.41,"Asphalt Shingle Roofing, Attic Insulation","98,96,97,99,3,1","Premium shingles, Class A, 300-385 lbs/ft2, pneumatic nailer
|
321
|
+
Asphalt felt, #15
|
322
|
+
Plywood underlayment 0.75' thick
|
323
|
+
9.5"" thick fibreglass, kraft coated ceiling insulation, 15"" wide blanket (RSI 5.28)
|
324
|
+
polyethylene 4 ml vapour barrier
|
325
|
+
gypsum wallboard 0.5 in thick
|
326
|
+
",NECB_2011
|
327
|
+
44,ROOF,BTAP-ExteriorRoof-IEAD-6,BTAP,8,ExteriorRoof,IEAD,6,Zone 5,5.46,"Asphalt Shingle Roofing, Attic Insulation","98,96,97,99,3,1","Premium shingles, Class A, 300-385 lbs/ft2, pneumatic nailer
|
328
|
+
Asphalt felt, #15
|
329
|
+
Plywood underlayment 0.75' thick
|
330
|
+
9.5"" thick fibreglass, kraft coated ceiling insulation, 15"" wide blanket (RSI 5.28)
|
331
|
+
polyethylene 4 ml vapour barrier
|
332
|
+
gypsum wallboard 0.5 in thick
|
333
|
+
",NECB_2011
|
334
|
+
45,ROOF,BTAP-ExteriorRoof-IEAD-6,BTAP,8,ExteriorRoof,IEAD,6,Zone 6,5.46,"Asphalt Shingle Roofing, Attic Insulation","98,96,97,99,3,1","Premium shingles, Class A, 300-385 lbs/ft2, pneumatic nailer
|
335
|
+
Asphalt felt, #15
|
336
|
+
Plywood underlayment 0.75' thick
|
337
|
+
9.5"" thick fibreglass, kraft coated ceiling insulation, 15"" wide blanket (RSI 5.28)
|
338
|
+
polyethylene 4 ml vapour barrier
|
339
|
+
gypsum wallboard 0.5 in thick
|
340
|
+
",NECB_2011
|
341
|
+
46,ROOF,BTAP-ExteriorRoof-IEAD-6,BTAP,8,ExteriorRoof,IEAD,6,Zone 7A,6.17,"Asphalt Shingle Roofing, Attic Insulation","98,96,97,105,3,1","Premium shingles, Class A, 300-385 lbs/ft2, pneumatic nailer
|
342
|
+
Asphalt felt, #15
|
343
|
+
Plywood underlayment 0.75' thick
|
344
|
+
16"" thick fibreglass blown ceiling (RSI 6.7)
|
345
|
+
polyethylene 4 ml vapour barrier
|
346
|
+
gypsum wallboard 0.5 in thick
|
347
|
+
",NECB_2011
|
348
|
+
47,ROOF,BTAP-ExteriorRoof-IEAD-6,BTAP,8,ExteriorRoof,IEAD,6,Zone 7B,6.17,"Asphalt Shingle Roofing, Attic Insulation","98,96,97,105,3,1","Premium shingles, Class A, 300-385 lbs/ft2, pneumatic nailer
|
349
|
+
Asphalt felt, #15
|
350
|
+
Plywood underlayment 0.75' thick
|
351
|
+
16"" thick fibreglass blown ceiling (RSI 6.7)
|
352
|
+
polyethylene 4 ml vapour barrier
|
353
|
+
gypsum wallboard 0.5 in thick
|
354
|
+
",NECB_2011
|
355
|
+
48,ROOF,BTAP-ExteriorRoof-IEAD-6,BTAP,8,ExteriorRoof,IEAD,6,Zone 8,7.04,"Asphalt Shingle Roofing, Attic Insulation","98,96,97,104,3,108","Premium shingles, Class A, 300-385 lbs/ft2, pneumatic nailer
|
356
|
+
Asphalt felt, #15
|
357
|
+
Plywood underlayment 0.75' thick
|
358
|
+
18"" thick fibreglass blown ceiling (RSI 7.9)
|
359
|
+
polyethylene 4 ml vapour barrier
|
360
|
+
gypsum wallboard 0.5 in thick
|
361
|
+
",NECB_2011
|
362
|
+
49,ROOF,BTAP-ExteriorRoof-Metal-1,BTAP,5,ExteriorRoof,Metal,1,Zone 4,4.41,"Steel Roofing, painted galvanized ","95,96,97,57,80,97","Zinc Steel roofing, 28 gauge, .020"" thick, 115 lb/ft2
|
363
|
+
Asphalt felt, #15
|
364
|
+
Plywood underlayment 0.75' thick
|
365
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
366
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
367
|
+
Plywood underlayment 0.75' thick
|
368
|
+
",NECB_2011
|
369
|
+
50,ROOF,BTAP-ExteriorRoof-Metal-1,BTAP,5,ExteriorRoof,Metal,1,Zone 5,5.46,"Steel Roofing, painted galvanized ","95,96,97,134,134,97","Zinc Steel roofing, 28 gauge, .020"" thick, 115 lb/ft2
|
370
|
+
Asphalt felt, #15
|
371
|
+
Plywood underlayment 0.75' thick
|
372
|
+
XPS, 3"" 2.64
|
373
|
+
XPS, 3"" 2.64
|
374
|
+
Plywood underlayment 0.75' thick
|
375
|
+
",NECB_2011
|
376
|
+
51,ROOF,BTAP-ExteriorRoof-Metal-1,BTAP,5,ExteriorRoof,Metal,1,Zone 6,5.46,"Steel Roofing, painted galvanized ","95,96,97,134,134,97","Zinc Steel roofing, 28 gauge, .020"" thick, 115 lb/ft2
|
377
|
+
Asphalt felt, #15
|
378
|
+
Plywood underlayment 0.75' thick
|
379
|
+
XPS, 3"" 2.64
|
380
|
+
XPS, 3"" 2.64
|
381
|
+
Plywood underlayment 0.75' thick
|
382
|
+
",NECB_2011
|
383
|
+
52,ROOF,BTAP-ExteriorRoof-Metal-1,BTAP,5,ExteriorRoof,Metal,1,Zone 7A,6.17,"Steel Roofing, painted galvanized ","95,96,97,80,80,150,97","Zinc Steel roofing, 28 gauge, .020"" thick, 115 lb/ft2
|
384
|
+
Asphalt felt, #15
|
385
|
+
Plywood underlayment 0.75' thick
|
386
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
387
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
388
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
389
|
+
Plywood underlayment 0.75' thick
|
390
|
+
",NECB_2011
|
391
|
+
53,ROOF,BTAP-ExteriorRoof-Metal-1,BTAP,5,ExteriorRoof,Metal,1,Zone 7B,6.17,"Steel Roofing, painted galvanized ","95,96,97,80,80,150,97","Zinc Steel roofing, 28 gauge, .020"" thick, 115 lb/ft2
|
392
|
+
Asphalt felt, #15
|
393
|
+
Plywood underlayment 0.75' thick
|
394
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
395
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
396
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
397
|
+
Plywood underlayment 0.75' thick
|
398
|
+
",NECB_2011
|
399
|
+
54,ROOF,BTAP-ExteriorRoof-Metal-1,BTAP,5,ExteriorRoof,Metal,1,Zone 8,7.04,"Steel Roofing, painted galvanized ","95,96,80,80,57,97","Zinc Steel roofing, 28 gauge, .020"" thick, 115 lb/ft2
|
400
|
+
Asphalt felt, #15
|
401
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
402
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
403
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
404
|
+
Plywood underlayment 0.75' thick
|
405
|
+
",NECB_2011
|
406
|
+
55,ROOF,BTAP-ExteriorRoof-Metal-2,BTAP,7,ExteriorRoof,Metal,2,Zone 4,4.41,"Steel Roofing, painted galvanized Attic Insulation","95,96,57,80,3,1","Zinc Steel roofing, 28 gauge, .020"" thick, 115 lb/ft2
|
407
|
+
Asphalt felt, #15
|
408
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
409
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
410
|
+
polyethylene 4 ml vapour barrier
|
411
|
+
gypsum wallboard 0.5 in thick
|
412
|
+
",NECB_2011
|
413
|
+
56,ROOF,BTAP-ExteriorRoof-Metal-2,BTAP,7,ExteriorRoof,Metal,2,Zone 5,5.46,"Steel Roofing, painted galvanized Attic Insulation","95,96,97,134,134,3,1","Zinc Steel roofing, 28 gauge, .020"" thick, 115 lb/ft2
|
414
|
+
Asphalt felt, #15
|
415
|
+
Plywood underlayment 0.75' thick
|
416
|
+
XPS, 3"" 2.64
|
417
|
+
XPS, 3"" 2.64
|
418
|
+
polyethylene 4 ml vapour barrier
|
419
|
+
gypsum wallboard 0.5 in thick
|
420
|
+
",NECB_2011
|
421
|
+
57,ROOF,BTAP-ExteriorRoof-Metal-2,BTAP,7,ExteriorRoof,Metal,2,Zone 6,5.46,"Steel Roofing, painted galvanized Attic Insulation","95,96,97,134,134,3,1","Zinc Steel roofing, 28 gauge, .020"" thick, 115 lb/ft2
|
422
|
+
Asphalt felt, #15
|
423
|
+
Plywood underlayment 0.75' thick
|
424
|
+
XPS, 3"" 2.64
|
425
|
+
XPS, 3"" 2.64
|
426
|
+
polyethylene 4 ml vapour barrier
|
427
|
+
gypsum wallboard 0.5 in thick
|
428
|
+
",NECB_2011
|
429
|
+
58,ROOF,BTAP-ExteriorRoof-Metal-2,BTAP,7,ExteriorRoof,Metal,2,Zone 7A,6.17,"Steel Roofing, painted galvanized Attic Insulation","95,96,97,80,80,150,3,1","Zinc Steel roofing, 28 gauge, .020"" thick, 115 lb/ft2
|
430
|
+
Asphalt felt, #15
|
431
|
+
Plywood underlayment 0.75' thick
|
432
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
433
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
434
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
435
|
+
polyethylene 4 ml vapour barrier
|
436
|
+
gypsum wallboard 0.5 in thick
|
437
|
+
",NECB_2011
|
438
|
+
59,ROOF,BTAP-ExteriorRoof-Metal-2,BTAP,7,ExteriorRoof,Metal,2,Zone 7B,6.17,"Steel Roofing, painted galvanized Attic Insulation","95,96,97,80,80,150,3,1","Zinc Steel roofing, 28 gauge, .020"" thick, 115 lb/ft2
|
439
|
+
Asphalt felt, #15
|
440
|
+
Plywood underlayment 0.75' thick
|
441
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
442
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
443
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
444
|
+
polyethylene 4 ml vapour barrier
|
445
|
+
gypsum wallboard 0.5 in thick
|
446
|
+
",NECB_2011
|
447
|
+
60,ROOF,BTAP-ExteriorRoof-Metal-2,BTAP,7,ExteriorRoof,Metal,2,Zone 8,7.04,"Steel Roofing, painted galvanized Attic Insulation","95,96,97,80,80,57,3,1","Zinc Steel roofing, 28 gauge, .020"" thick, 115 lb/ft2
|
448
|
+
Asphalt felt, #15
|
449
|
+
Plywood underlayment 0.75' thick
|
450
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
451
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
452
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
453
|
+
polyethylene 4 ml vapour barrier
|
454
|
+
gypsum wallboard 0.5 in thick
|
455
|
+
",NECB_2011
|
456
|
+
61,WALLS,BTAP-ExteriorWall-Mass-1,BTAP,7,ExteriorWall,Mass,1,Zone 4,3.18,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Insulated 2 x 6 Wooden Stud Wall","1,138,3,4,5,6,24,25,26,27,28","gypsum wallboard 0.5 in thick
|
457
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
458
|
+
polyethylene 4 ml vapour barrier
|
459
|
+
foil face fibreglass batts, 5"" thick, 15"" wide, RSI 3.36
|
460
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
461
|
+
weather barrier, spunbonded polyethylene
|
462
|
+
Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
463
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
464
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
465
|
+
Control joint, PVC
|
466
|
+
Grout, 8"" thick including pumping
|
467
|
+
",NECB_2011
|
468
|
+
62,WALLS,BTAP-ExteriorWall-Mass-1,BTAP,7,ExteriorWall,Mass,1,Zone 5,3.6,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Insulated 2 x 6 Wooden Stud Wall","1,138,3,4,5,6,54,24,25,26,27,28","gypsum wallboard 0.5 in thick
|
469
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
470
|
+
polyethylene 4 ml vapour barrier
|
471
|
+
foil face fibreglass batts, 5"" thick, 15"" wide, RSI 3.36
|
472
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
473
|
+
weather barrier, spunbonded polyethylene
|
474
|
+
0.5"" Isoboard, 4 x 8 sheet, foil faced (RSI 0.48)
|
475
|
+
Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
476
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
477
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
478
|
+
Control joint, PVC
|
479
|
+
Grout, 8"" thick including pumping
|
480
|
+
",NECB_2011
|
481
|
+
63,WALLS,BTAP-ExteriorWall-Mass-1,BTAP,7,ExteriorWall,Mass,1,Zone 6,4.05,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Insulated 2 x 6 Wooden Stud Wall","1,138,3,43,6,56,24,25,26,27,28","gypsum wallboard 0.5 in thick
|
482
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
483
|
+
polyethylene 4 ml vapour barrier
|
484
|
+
fibreglass batts, 6 in thick RSI 3.35
|
485
|
+
weather barrier, spunbonded polyethylene
|
486
|
+
Isoboard, 1"" thick, RSI .98
|
487
|
+
Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
488
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
489
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
490
|
+
Control joint, PVC
|
491
|
+
Grout, 8"" thick including pumping
|
492
|
+
",NECB_2011
|
493
|
+
64,WALLS,BTAP-ExteriorWall-Mass-1,BTAP,7,ExteriorWall,Mass,1,Zone 7A,4.76,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Insulated 2 x 6 Wooden Stud Wall","1,138,3,53,6,56,24,25,26,27,28","gypsum wallboard 0.5 in thick
|
494
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
495
|
+
polyethylene 4 ml vapour barrier
|
496
|
+
foil face fibreglass batts, 6 "" thick, 15"" wide, RSI 3.52
|
497
|
+
weather barrier, spunbonded polyethylene
|
498
|
+
Isoboard, 1"" thick, RSI .98
|
499
|
+
Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
500
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
501
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
502
|
+
Control joint, PVC
|
503
|
+
Grout, 8"" thick including pumping
|
504
|
+
",NECB_2011
|
505
|
+
65,WALLS,BTAP-ExteriorWall-Mass-1,BTAP,7,ExteriorWall,Mass,1,Zone 7B,4.76,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Insulated 2 x 6 Wooden Stud Wall","1,138,3,53,6,56,24,25,26,27,28","gypsum wallboard 0.5 in thick
|
506
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
507
|
+
polyethylene 4 ml vapour barrier
|
508
|
+
foil face fibreglass batts, 6 "" thick, 15"" wide, RSI 3.52
|
509
|
+
weather barrier, spunbonded polyethylene
|
510
|
+
Isoboard, 1"" thick, RSI .98
|
511
|
+
Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
512
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
513
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
514
|
+
Control joint, PVC
|
515
|
+
Grout, 8"" thick including pumping
|
516
|
+
",NECB_2011
|
517
|
+
66,WALLS,BTAP-ExteriorWall-Mass-1,BTAP,7,ExteriorWall,Mass,1,Zone 8,5.46,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Insulated 2 x 6 Wooden Stud Wall","1,138,3,53,6,63,24,25,26,27,28","gypsum wallboard 0.5 in thick
|
518
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
519
|
+
polyethylene 4 ml vapour barrier
|
520
|
+
foil face fibreglass batts, 6 "" thick, 15"" wide, RSI 3.52
|
521
|
+
weather barrier, spunbonded polyethylene
|
522
|
+
Isoboard, 1.5"" thick, RSI 1.38
|
523
|
+
Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
524
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
525
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
526
|
+
Control joint, PVC
|
527
|
+
Grout, 8"" thick including pumping
|
528
|
+
",NECB_2011
|
529
|
+
67,WALLS,BTAP-ExteriorWall-Mass-2,BTAP,8,ExteriorWall,Mass,2,Zone 4,3.18,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,40,40,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
530
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
531
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
532
|
+
Control joint, PVC
|
533
|
+
Grout, 8"" thick including pumping
|
534
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
535
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
536
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
537
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
538
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
539
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
540
|
+
",NECB_2011
|
541
|
+
68,WALLS,BTAP-ExteriorWall-Mass-2,BTAP,8,ExteriorWall,Mass,2,Zone 5,3.6,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,40,40,158,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
542
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
543
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
544
|
+
Control joint, PVC
|
545
|
+
Grout, 8"" thick including pumping
|
546
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
547
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
548
|
+
XPS, 3/4"" RSI 0.501
|
549
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
550
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
551
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
552
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
553
|
+
",NECB_2011
|
554
|
+
69,WALLS,BTAP-ExteriorWall-Mass-2,BTAP,8,ExteriorWall,Mass,2,Zone 6,4.05,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,57,150,40,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
555
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
556
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
557
|
+
Control joint, PVC
|
558
|
+
Grout, 8"" thick including pumping
|
559
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
560
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
561
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
562
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
563
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
564
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
565
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
566
|
+
",NECB_2011
|
567
|
+
70,WALLS,BTAP-ExteriorWall-Mass-2,BTAP,8,ExteriorWall,Mass,2,Zone 7A,4.76,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,57,57,150,158,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
568
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
569
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
570
|
+
Control joint, PVC
|
571
|
+
Grout, 8"" thick including pumping
|
572
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
573
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
574
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
575
|
+
XPS, 3/4"" RSI 0.501
|
576
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
577
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
578
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
579
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
580
|
+
",NECB_2011
|
581
|
+
72,WALLS,BTAP-ExteriorWall-Mass-2,BTAP,8,ExteriorWall,Mass,2,Zone 8,5.46,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,57,57,57,158,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
582
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
583
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
584
|
+
Control joint, PVC
|
585
|
+
Grout, 8"" thick including pumping
|
586
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
587
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
588
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
589
|
+
XPS, 3/4"" RSI 0.501
|
590
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
591
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
592
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
593
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
594
|
+
",NECB_2011
|
595
|
+
73,WALLS,BTAP-ExteriorWall-Mass-3,BTAP,9,ExteriorWall,Mass,3,Zone 4,3.18,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,40,40,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
596
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
597
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
598
|
+
Control joint, PVC
|
599
|
+
Grout, 8"" thick including pumping
|
600
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
601
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
602
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
603
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
604
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
605
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
606
|
+
",NECB_2011
|
607
|
+
74,WALLS,BTAP-ExteriorWall-Mass-3,BTAP,9,ExteriorWall,Mass,3,Zone 5,3.6,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,40,40,158,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
608
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
609
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
610
|
+
Control joint, PVC
|
611
|
+
Grout, 8"" thick including pumping
|
612
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
613
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
614
|
+
XPS, 3/4"" RSI 0.501
|
615
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
616
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
617
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
618
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
619
|
+
",NECB_2011
|
620
|
+
75,WALLS,BTAP-ExteriorWall-Mass-3,BTAP,9,ExteriorWall,Mass,3,Zone 6,4.05,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,57,150,40,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
621
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
622
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
623
|
+
Control joint, PVC
|
624
|
+
Grout, 8"" thick including pumping
|
625
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
626
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
627
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
628
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
629
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
630
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
631
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
632
|
+
",NECB_2011
|
633
|
+
76,WALLS,BTAP-ExteriorWall-Mass-3,BTAP,9,ExteriorWall,Mass,3,Zone 7A,4.76,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,57,57,150,158,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
634
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
635
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
636
|
+
Control joint, PVC
|
637
|
+
Grout, 8"" thick including pumping
|
638
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
639
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
640
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
641
|
+
XPS, 3/4"" RSI 0.501
|
642
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
643
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
644
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
645
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
646
|
+
",NECB_2011
|
647
|
+
77,WALLS,BTAP-ExteriorWall-Mass-3,BTAP,9,ExteriorWall,Mass,3,Zone 7B,4.76,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,57,57,150,158,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
648
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
649
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
650
|
+
Control joint, PVC
|
651
|
+
Grout, 8"" thick including pumping
|
652
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
653
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
654
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
655
|
+
XPS, 3/4"" RSI 0.501
|
656
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
657
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
658
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
659
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
660
|
+
",NECB_2011
|
661
|
+
78,WALLS,BTAP-ExteriorWall-Mass-3,BTAP,9,ExteriorWall,Mass,3,Zone 8,5.46,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,57,57,57,158,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
662
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
663
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
664
|
+
Control joint, PVC
|
665
|
+
Grout, 8"" thick including pumping
|
666
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
667
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
668
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
669
|
+
XPS, 3/4"" RSI 0.501
|
670
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
671
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
672
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
673
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
674
|
+
",NECB_2011
|
675
|
+
79,WALLS,BTAP-ExteriorWall-Mass-4,BTAP,10,ExteriorWall,Mass,4,Zone 4,3.18,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,40,40,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
676
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
677
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
678
|
+
Control joint, PVC
|
679
|
+
Grout, 8"" thick including pumping
|
680
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
681
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
682
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
683
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
684
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
685
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
686
|
+
",NECB_2011
|
687
|
+
80,WALLS,BTAP-ExteriorWall-Mass-4,BTAP,10,ExteriorWall,Mass,4,Zone 5,3.6,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,40,40,158,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
688
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
689
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
690
|
+
Control joint, PVC
|
691
|
+
Grout, 8"" thick including pumping
|
692
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
693
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
694
|
+
XPS, 3/4"" RSI 0.501
|
695
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
696
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
697
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
698
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
699
|
+
",NECB_2011
|
700
|
+
81,WALLS,BTAP-ExteriorWall-Mass-4,BTAP,10,ExteriorWall,Mass,4,Zone 6,4.05,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,57,150,40,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
701
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
702
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
703
|
+
Control joint, PVC
|
704
|
+
Grout, 8"" thick including pumping
|
705
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
706
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
707
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
708
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
709
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
710
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
711
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
712
|
+
",NECB_2011
|
713
|
+
82,WALLS,BTAP-ExteriorWall-Mass-4,BTAP,10,ExteriorWall,Mass,4,Zone 7A,4.76,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,57,57,150,158,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
714
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
715
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
716
|
+
Control joint, PVC
|
717
|
+
Grout, 8"" thick including pumping
|
718
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
719
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
720
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
721
|
+
XPS, 3/4"" RSI 0.501
|
722
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
723
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
724
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
725
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
726
|
+
",NECB_2011
|
727
|
+
84,WALLS,BTAP-ExteriorWall-Mass-4,BTAP,10,ExteriorWall,Mass,4,Zone 8,5.46,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,57,57,57,158,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
728
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
729
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
730
|
+
Control joint, PVC
|
731
|
+
Grout, 8"" thick including pumping
|
732
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
733
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
734
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
735
|
+
XPS, 3/4"" RSI 0.501
|
736
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
737
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
738
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
739
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
740
|
+
",NECB_2011
|
741
|
+
85,WALLS,BTAP-ExteriorWall-Mass-5,BTAP,11,ExteriorWall,Mass,5,Zone 4,3.18,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,40,40,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
742
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
743
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
744
|
+
Control joint, PVC
|
745
|
+
Grout, 8"" thick including pumping
|
746
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
747
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
748
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
749
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
750
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
751
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
752
|
+
",NECB_2011
|
753
|
+
86,WALLS,BTAP-ExteriorWall-Mass-5,BTAP,11,ExteriorWall,Mass,5,Zone 5,3.6,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,40,40,158,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
754
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
755
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
756
|
+
Control joint, PVC
|
757
|
+
Grout, 8"" thick including pumping
|
758
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
759
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
760
|
+
XPS, 3/4"" RSI 0.501
|
761
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
762
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
763
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
764
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
765
|
+
",NECB_2011
|
766
|
+
87,WALLS,BTAP-ExteriorWall-Mass-5,BTAP,11,ExteriorWall,Mass,5,Zone 6,4.05,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,57,150,40,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
767
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
768
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
769
|
+
Control joint, PVC
|
770
|
+
Grout, 8"" thick including pumping
|
771
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
772
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
773
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
774
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
775
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
776
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
777
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
778
|
+
",NECB_2011
|
779
|
+
88,WALLS,BTAP-ExteriorWall-Mass-5,BTAP,11,ExteriorWall,Mass,5,Zone 7A,4.76,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,57,57,150,158,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
780
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
781
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
782
|
+
Control joint, PVC
|
783
|
+
Grout, 8"" thick including pumping
|
784
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
785
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
786
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
787
|
+
XPS, 3/4"" RSI 0.501
|
788
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
789
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
790
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
791
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
792
|
+
",NECB_2011
|
793
|
+
89,WALLS,BTAP-ExteriorWall-Mass-5,BTAP,11,ExteriorWall,Mass,5,Zone 7B,4.76,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,57,57,150,158,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
794
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
795
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
796
|
+
Control joint, PVC
|
797
|
+
Grout, 8"" thick including pumping
|
798
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
799
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
800
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
801
|
+
XPS, 3/4"" RSI 0.501
|
802
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
803
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
804
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
805
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
806
|
+
",NECB_2011
|
807
|
+
90,WALLS,BTAP-ExteriorWall-Mass-5,BTAP,11,ExteriorWall,Mass,5,Zone 8,5.46,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,57,57,57,158,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
808
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
809
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
810
|
+
Control joint, PVC
|
811
|
+
Grout, 8"" thick including pumping
|
812
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
813
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
814
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
815
|
+
XPS, 3/4"" RSI 0.501
|
816
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
817
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
818
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
819
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
820
|
+
",NECB_2011
|
821
|
+
91,UNF-WALLS,BTAP-ExteriorWall-Mass-6,BTAP,15,ExteriorWall,Mass,6,Zone 4,3.18,"Unfinished Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted ","24,25,26,27,28,40,40,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
822
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
823
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
824
|
+
Control joint, PVC
|
825
|
+
Grout, 8"" thick including pumping
|
826
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
827
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
828
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
829
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
830
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
831
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
832
|
+
",NECB_2011
|
833
|
+
92,UNF-WALLS,BTAP-ExteriorWall-Mass-6,BTAP,15,ExteriorWall,Mass,6,Zone 5,3.6,"Unfinished Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted ","24,25,26,27,28,40,40,158,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
834
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
835
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
836
|
+
Control joint, PVC
|
837
|
+
Grout, 8"" thick including pumping
|
838
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
839
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
840
|
+
XPS, 3/4"" RSI 0.501
|
841
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
842
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
843
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
844
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
845
|
+
",NECB_2011
|
846
|
+
93,UNF-WALLS,BTAP-ExteriorWall-Mass-6,BTAP,15,ExteriorWall,Mass,6,Zone 6,4.05,"Unfinished Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted ","24,25,26,27,28,57,150,40,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
847
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
848
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
849
|
+
Control joint, PVC
|
850
|
+
Grout, 8"" thick including pumping
|
851
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
852
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
853
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
854
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
855
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
856
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
857
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
858
|
+
",NECB_2011
|
859
|
+
94,UNF-WALLS,BTAP-ExteriorWall-Mass-6,BTAP,15,ExteriorWall,Mass,6,Zone 7A,4.76,"Unfinished Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted ","24,25,26,27,28,57,57,150,158,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
860
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
861
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
862
|
+
Control joint, PVC
|
863
|
+
Grout, 8"" thick including pumping
|
864
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
865
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
866
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
867
|
+
XPS, 3/4"" RSI 0.501
|
868
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
869
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
870
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
871
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
872
|
+
",NECB_2011
|
873
|
+
95,UNF-WALLS,BTAP-ExteriorWall-Mass-6,BTAP,15,ExteriorWall,Mass,6,Zone 7B,4.76,"Unfinished Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted ","24,25,26,27,28,57,57,150,158,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
874
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
875
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
876
|
+
Control joint, PVC
|
877
|
+
Grout, 8"" thick including pumping
|
878
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
879
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
880
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
881
|
+
XPS, 3/4"" RSI 0.501
|
882
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
883
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
884
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
885
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
886
|
+
",NECB_2011
|
887
|
+
96,UNF-WALLS,BTAP-ExteriorWall-Mass-6,BTAP,15,ExteriorWall,Mass,6,Zone 8,5.46,"Unfinished Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted ","24,25,26,27,28,57,57,57,158,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
888
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
889
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
890
|
+
Control joint, PVC
|
891
|
+
Grout, 8"" thick including pumping
|
892
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
893
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
894
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
895
|
+
XPS, 3/4"" RSI 0.501
|
896
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
897
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
898
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
899
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
900
|
+
",NECB_2011
|
901
|
+
97,UNF-WALLS,BTAP-ExteriorWall-Mass-7,BTAP,16,ExteriorWall,Mass,7,Zone 4,3.18,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,40,40,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
902
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
903
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
904
|
+
Control joint, PVC
|
905
|
+
Grout, 8"" thick including pumping
|
906
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
907
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
908
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
909
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
910
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
911
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
912
|
+
",NECB_2011
|
913
|
+
98,UNF-WALLS,BTAP-ExteriorWall-Mass-7,BTAP,16,ExteriorWall,Mass,7,Zone 5,3.6,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,40,40,158,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
914
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
915
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
916
|
+
Control joint, PVC
|
917
|
+
Grout, 8"" thick including pumping
|
918
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
919
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
920
|
+
XPS, 3/4"" RSI 0.501
|
921
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
922
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
923
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
924
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
925
|
+
",NECB_2011
|
926
|
+
99,UNF-WALLS,BTAP-ExteriorWall-Mass-7,BTAP,16,ExteriorWall,Mass,7,Zone 6,4.05,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,57,150,40,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
927
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
928
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
929
|
+
Control joint, PVC
|
930
|
+
Grout, 8"" thick including pumping
|
931
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
932
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
933
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
934
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
935
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
936
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
937
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
938
|
+
",NECB_2011
|
939
|
+
100,UNF-WALLS,BTAP-ExteriorWall-Mass-7,BTAP,16,ExteriorWall,Mass,7,Zone 7A,4.76,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,57,57,150,158,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
940
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
941
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
942
|
+
Control joint, PVC
|
943
|
+
Grout, 8"" thick including pumping
|
944
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
945
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
946
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
947
|
+
XPS, 3/4"" RSI 0.501
|
948
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
949
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
950
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
951
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
952
|
+
",NECB_2011
|
953
|
+
101,UNF-WALLS,BTAP-ExteriorWall-Mass-7,BTAP,16,ExteriorWall,Mass,7,Zone 7B,4.76,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,57,57,150,158,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
954
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
955
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
956
|
+
Control joint, PVC
|
957
|
+
Grout, 8"" thick including pumping
|
958
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
959
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
960
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
961
|
+
XPS, 3/4"" RSI 0.501
|
962
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
963
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
964
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
965
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
966
|
+
",NECB_2011
|
967
|
+
102,UNF-WALLS,BTAP-ExteriorWall-Mass-7,BTAP,16,ExteriorWall,Mass,7,Zone 8,5.46,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,57,57,57,158,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
968
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
969
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
970
|
+
Control joint, PVC
|
971
|
+
Grout, 8"" thick including pumping
|
972
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
973
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
974
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
975
|
+
XPS, 3/4"" RSI 0.501
|
976
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
977
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
978
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
979
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
980
|
+
",NECB_2011
|
981
|
+
103,UNF-WALLS,BTAP-ExteriorWall-Mass-8,BTAP,17,ExteriorWall,Mass,8,Zone 4,3.18,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,40,40,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
982
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
983
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
984
|
+
Control joint, PVC
|
985
|
+
Grout, 8"" thick including pumping
|
986
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
987
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
988
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
989
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
990
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
991
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
992
|
+
",NECB_2011
|
993
|
+
104,UNF-WALLS,BTAP-ExteriorWall-Mass-8,BTAP,17,ExteriorWall,Mass,8,Zone 5,3.6,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,40,40,158,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
994
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
995
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
996
|
+
Control joint, PVC
|
997
|
+
Grout, 8"" thick including pumping
|
998
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
999
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
1000
|
+
XPS, 3/4"" RSI 0.501
|
1001
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
1002
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
1003
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
1004
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1005
|
+
",NECB_2011
|
1006
|
+
105,UNF-WALLS,BTAP-ExteriorWall-Mass-8,BTAP,17,ExteriorWall,Mass,8,Zone 6,4.05,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,57,150,40,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
1007
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
1008
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
1009
|
+
Control joint, PVC
|
1010
|
+
Grout, 8"" thick including pumping
|
1011
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
1012
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
1013
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
1014
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
1015
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
1016
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
1017
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1018
|
+
",NECB_2011
|
1019
|
+
106,UNF-WALLS,BTAP-ExteriorWall-Mass-8,BTAP,17,ExteriorWall,Mass,8,Zone 7A,4.76,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,57,57,150,158,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
1020
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
1021
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
1022
|
+
Control joint, PVC
|
1023
|
+
Grout, 8"" thick including pumping
|
1024
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
1025
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
1026
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
1027
|
+
XPS, 3/4"" RSI 0.501
|
1028
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
1029
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
1030
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
1031
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1032
|
+
",NECB_2011
|
1033
|
+
107,UNF-WALLS,BTAP-ExteriorWall-Mass-8,BTAP,17,ExteriorWall,Mass,8,Zone 7B,4.76,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,57,57,150,158,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
1034
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
1035
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
1036
|
+
Control joint, PVC
|
1037
|
+
Grout, 8"" thick including pumping
|
1038
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
1039
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
1040
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
1041
|
+
XPS, 3/4"" RSI 0.501
|
1042
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
1043
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
1044
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
1045
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1046
|
+
",NECB_2011
|
1047
|
+
108,UNF-WALLS,BTAP-ExteriorWall-Mass-8,BTAP,17,ExteriorWall,Mass,8,Zone 8,5.46,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,57,57,57,158,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
1048
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
1049
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
1050
|
+
Control joint, PVC
|
1051
|
+
Grout, 8"" thick including pumping
|
1052
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
1053
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
1054
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
1055
|
+
XPS, 3/4"" RSI 0.501
|
1056
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
1057
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
1058
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
1059
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1060
|
+
",NECB_2011
|
1061
|
+
109,UNF-WALLS,BTAP-ExteriorWall-Mass-9,BTAP,18,ExteriorWall,Mass,9,Zone 4,3.18,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,40,40,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
1062
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
1063
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
1064
|
+
Control joint, PVC
|
1065
|
+
Grout, 8"" thick including pumping
|
1066
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
1067
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
1068
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
1069
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
1070
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
1071
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1072
|
+
",NECB_2011
|
1073
|
+
110,UNF-WALLS,BTAP-ExteriorWall-Mass-9,BTAP,18,ExteriorWall,Mass,9,Zone 5,3.6,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,40,40,158,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
1074
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
1075
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
1076
|
+
Control joint, PVC
|
1077
|
+
Grout, 8"" thick including pumping
|
1078
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
1079
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
1080
|
+
XPS, 3/4"" RSI 0.501
|
1081
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
1082
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
1083
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
1084
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1085
|
+
",NECB_2011
|
1086
|
+
111,UNF-WALLS,BTAP-ExteriorWall-Mass-9,BTAP,18,ExteriorWall,Mass,9,Zone 6,4.05,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,57,150,40,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
1087
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
1088
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
1089
|
+
Control joint, PVC
|
1090
|
+
Grout, 8"" thick including pumping
|
1091
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
1092
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
1093
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
1094
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
1095
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
1096
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
1097
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1098
|
+
",NECB_2011
|
1099
|
+
112,UNF-WALLS,BTAP-ExteriorWall-Mass-9,BTAP,18,ExteriorWall,Mass,9,Zone 7A,4.76,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,57,57,150,158,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
1100
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
1101
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
1102
|
+
Control joint, PVC
|
1103
|
+
Grout, 8"" thick including pumping
|
1104
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
1105
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
1106
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
1107
|
+
XPS, 3/4"" RSI 0.501
|
1108
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
1109
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
1110
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
1111
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1112
|
+
",NECB_2011
|
1113
|
+
113,UNF-WALLS,BTAP-ExteriorWall-Mass-9,BTAP,18,ExteriorWall,Mass,9,Zone 7B,4.76,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,57,57,150,158,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
1114
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
1115
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
1116
|
+
Control joint, PVC
|
1117
|
+
Grout, 8"" thick including pumping
|
1118
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
1119
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
1120
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
1121
|
+
XPS, 3/4"" RSI 0.501
|
1122
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
1123
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
1124
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
1125
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1126
|
+
",NECB_2011
|
1127
|
+
114,UNF-WALLS,BTAP-ExteriorWall-Mass-9,BTAP,18,ExteriorWall,Mass,9,Zone 8,5.46,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted with Exterior Brick veneer wall","24,25,26,27,28,57,57,57,158,20,21,139,141","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
1128
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
1129
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
1130
|
+
Control joint, PVC
|
1131
|
+
Grout, 8"" thick including pumping
|
1132
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
1133
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
1134
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
1135
|
+
XPS, 3/4"" RSI 0.501
|
1136
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
1137
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
1138
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
1139
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1140
|
+
",NECB_2011
|
1141
|
+
115,WALLS,BTAP-ExteriorWall-Metal-1,BTAP,12,ExteriorWall,Metal,1,Zone 4,3.18,"Steel Sandwich Panel Wall, 4.5 in thick with 2 "" polystyrene, and interior insulated wall","1,11,43,6,56,150,48","gypsum wallboard 0.5 in thick
|
1142
|
+
galvanized LB studs, 16 ga x 3-5/8\"" W studs 16\"" O.C. x 10' H, incl galvanized top & bottom track, excl openings, headers, beams, bracing & bridging
|
1143
|
+
fibreglass batts, 6 in thick RSI 3.35
|
1144
|
+
weather barrier, spunbonded polyethylene
|
1145
|
+
Isoboard, 1"" thick, RSI .98
|
1146
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
1147
|
+
Steel siding, factory panel, galvanized, 22 gauge, colored 1 side and baked enamal exterior finish, includes 2 in. polystyrene modified to 3"" PS
|
1148
|
+
",NECB_2011
|
1149
|
+
116,WALLS,BTAP-ExteriorWall-Metal-1,BTAP,12,ExteriorWall,Metal,1,Zone 5,3.6,"Steel Sandwich Panel Wall, 4.5 in thick with 4"" XPS and interior insulated wall","1,11,43,6,48,55","gypsum wallboard 0.5 in thick
|
1150
|
+
galvanized LB studs, 16 ga x 3-5/8\"" W studs 16\"" O.C. x 10' H, incl galvanized top & bottom track, excl openings, headers, beams, bracing & bridging
|
1151
|
+
fibreglass batts, 6 in thick RSI 3.35
|
1152
|
+
weather barrier, spunbonded polyethylene
|
1153
|
+
Steel siding, factory panel, galvanized, 22 gauge, colored 1 side and baked enamal exterior finish, includes 2 in. polystyrene modified to 3"" PS
|
1154
|
+
XPS, 25 PSI, 2"" RSI 1.76 modified to 2 x 2.5"" sheets: total 5"" RSI 4.4
|
1155
|
+
",NECB_2011
|
1156
|
+
117,WALLS,BTAP-ExteriorWall-Metal-1,BTAP,12,ExteriorWall,Metal,1,Zone 6,4.05,"Steel Sandwich Panel Wall, 5 in thick with 4 "" XPS, and interior insulated wall","1,11,43,56,6,48,59","gypsum wallboard 0.5 in thick
|
1157
|
+
galvanized LB studs, 16 ga x 3-5/8\"" W studs 16\"" O.C. x 10' H, incl galvanized top & bottom track, excl openings, headers, beams, bracing & bridging
|
1158
|
+
fibreglass batts, 6 in thick RSI 3.35
|
1159
|
+
Isoboard, 1"" thick, RSI .98
|
1160
|
+
weather barrier, spunbonded polyethylene
|
1161
|
+
Steel siding, factory panel, galvanized, 22 gauge, colored 1 side and baked enamal exterior finish, includes 2 in. polystyrene modified to 3"" PS
|
1162
|
+
XPS, 25 PSI, 2"" RSI 1.76 modified to 3 x 2"" sheets RSI 5.28
|
1163
|
+
",NECB_2011
|
1164
|
+
118,WALLS,BTAP-ExteriorWall-Metal-1,BTAP,12,ExteriorWall,Metal,1,Zone 7A,4.76,"Steel Sandwich Panel Wall, 6 in thick with 5 "" XPS and interior insulated wall","1,11,43,63,6,48,59","gypsum wallboard 0.5 in thick
|
1165
|
+
galvanized LB studs, 16 ga x 3-5/8\"" W studs 16\"" O.C. x 10' H, incl galvanized top & bottom track, excl openings, headers, beams, bracing & bridging
|
1166
|
+
fibreglass batts, 6 in thick RSI 3.35
|
1167
|
+
Isoboard, 1.5"" thick, RSI 1.38
|
1168
|
+
weather barrier, spunbonded polyethylene
|
1169
|
+
Steel siding, factory panel, galvanized, 22 gauge, colored 1 side and baked enamal exterior finish, includes 2 in. polystyrene modified to 3"" PS
|
1170
|
+
XPS, 25 PSI, 2"" RSI 1.76 modified to 3 x 2"" sheets RSI 5.28
|
1171
|
+
",NECB_2011
|
1172
|
+
119,WALLS,BTAP-ExteriorWall-Metal-1,BTAP,12,ExteriorWall,Metal,1,Zone 7B,4.76,"Steel Sandwich Panel Wall, 6 in thick with 5 "" XPS and interior insulated wall","1,11,43,63,6,48,59","gypsum wallboard 0.5 in thick
|
1173
|
+
galvanized LB studs, 16 ga x 3-5/8\"" W studs 16\"" O.C. x 10' H, incl galvanized top & bottom track, excl openings, headers, beams, bracing & bridging
|
1174
|
+
fibreglass batts, 6 in thick RSI 3.35
|
1175
|
+
Isoboard, 1.5"" thick, RSI 1.38
|
1176
|
+
weather barrier, spunbonded polyethylene
|
1177
|
+
Steel siding, factory panel, galvanized, 22 gauge, colored 1 side and baked enamal exterior finish, includes 2 in. polystyrene modified to 3"" PS
|
1178
|
+
XPS, 25 PSI, 2"" RSI 1.76 modified to 3 x 2"" sheets RSI 5.28
|
1179
|
+
",NECB_2011
|
1180
|
+
120,WALLS,BTAP-ExteriorWall-Metal-1,BTAP,12,ExteriorWall,Metal,1,Zone 8,5.46,"Steel Sandwich Panel Wall, 6 in thick with 6 "" XPS and interior insulated wall","1,11,43,58,6,48,59","gypsum wallboard 0.5 in thick
|
1181
|
+
galvanized LB studs, 16 ga x 3-5/8\"" W studs 16\"" O.C. x 10' H, incl galvanized top & bottom track, excl openings, headers, beams, bracing & bridging
|
1182
|
+
fibreglass batts, 6 in thick RSI 3.35
|
1183
|
+
XPS, 25 PSI, 2"" RSI 1.76 modified to 2 x 2.25"" sheets RSI 4
|
1184
|
+
weather barrier, spunbonded polyethylene
|
1185
|
+
Steel siding, factory panel, galvanized, 22 gauge, colored 1 side and baked enamal exterior finish, includes 2 in. polystyrene modified to 3"" PS
|
1186
|
+
XPS, 25 PSI, 2"" RSI 1.76 modified to 3 x 2"" sheets RSI 5.28
|
1187
|
+
",NECB_2011
|
1188
|
+
121,WALLS,BTAP-ExteriorWall-Metal-2,BTAP,13,ExteriorWall,Metal,2,Zone 4,3.18,Curtainwall: Glazed Spandrel,"1,11,43,6,50,51","gypsum wallboard 0.5 in thick
|
1189
|
+
galvanized LB studs, 16 ga x 3-5/8\"" W studs 16\"" O.C. x 10' H, incl galvanized top & bottom track, excl openings, headers, beams, bracing & bridging
|
1190
|
+
fibreglass batts, 6 in thick RSI 3.35
|
1191
|
+
weather barrier, spunbonded polyethylene
|
1192
|
+
Spandrel glass 3/8"" plate
|
1193
|
+
Aluminum panel with 2 inches fibreglass
|
1194
|
+
",NECB_2011
|
1195
|
+
122,WALLS,BTAP-ExteriorWall-Metal-2,BTAP,13,ExteriorWall,Metal,2,Zone 5,3.6,Curtainwall: Glazed Spandrel,"1,11,160,6,50,51","gypsum wallboard 0.5 in thick
|
1196
|
+
galvanized LB studs, 16 ga x 3-5/8\"" W studs 16\"" O.C. x 10' H, incl galvanized top & bottom track, excl openings, headers, beams, bracing & bridging
|
1197
|
+
Fibreglass Foil Faced 6 "" RSI 3.7 batts
|
1198
|
+
weather barrier, spunbonded polyethylene
|
1199
|
+
Spandrel glass 3/8"" plate
|
1200
|
+
Aluminum panel with 2 inches fibreglass
|
1201
|
+
",NECB_2011
|
1202
|
+
123,WALLS,BTAP-ExteriorWall-Metal-2,BTAP,13,ExteriorWall,Metal,2,Zone 6,4.05,Curtainwall: Glazed Spandrel,"1,11,161,162,6,50,51","gypsum wallboard 0.5 in thick
|
1203
|
+
galvanized LB studs, 16 ga x 3-5/8\"" W studs 16\"" O.C. x 10' H, incl galvanized top & bottom track, excl openings, headers, beams, bracing & bridging
|
1204
|
+
Kraft faced fiberglass, 3-1/2"" thick, 23"" wide, RSI1.93
|
1205
|
+
Kraft faced fiberglass, 3-1/2"" thick, 23"" wide, RSI2.29
|
1206
|
+
weather barrier, spunbonded polyethylene
|
1207
|
+
Spandrel glass 3/8"" plate
|
1208
|
+
Aluminum panel with 2 inches fibreglass
|
1209
|
+
",NECB_2011
|
1210
|
+
124,WALLS,BTAP-ExteriorWall-Metal-2,BTAP,13,ExteriorWall,Metal,2,Zone 7A,4.76,Curtainwall: Glazed Spandrel,"1,11,60,161,6,50,51","gypsum wallboard 0.5 in thick
|
1211
|
+
galvanized LB studs, 16 ga x 3-5/8\"" W studs 16\"" O.C. x 10' H, incl galvanized top & bottom track, excl openings, headers, beams, bracing & bridging
|
1212
|
+
fibreglass batts, 6 in thick RSI3.35
|
1213
|
+
Kraft faced fiberglass, 3-1/2"" thick, 23"" wide, RSI1.93
|
1214
|
+
weather barrier, spunbonded polyethylene
|
1215
|
+
Spandrel glass 3/8"" plate
|
1216
|
+
Aluminum panel with 2 inches fibreglass
|
1217
|
+
",NECB_2011
|
1218
|
+
125,WALLS,BTAP-ExteriorWall-Metal-2,BTAP,13,ExteriorWall,Metal,2,Zone 7B,4.76,Curtainwall: Glazed Spandrel,"1,11,60,161,6,50,51","gypsum wallboard 0.5 in thick
|
1219
|
+
galvanized LB studs, 16 ga x 3-5/8\"" W studs 16\"" O.C. x 10' H, incl galvanized top & bottom track, excl openings, headers, beams, bracing & bridging
|
1220
|
+
fibreglass batts, 6 in thick RSI3.35
|
1221
|
+
Kraft faced fiberglass, 3-1/2"" thick, 23"" wide, RSI1.93
|
1222
|
+
weather barrier, spunbonded polyethylene
|
1223
|
+
Spandrel glass 3/8"" plate
|
1224
|
+
Aluminum panel with 2 inches fibreglass
|
1225
|
+
",NECB_2011
|
1226
|
+
126,WALLS,BTAP-ExteriorWall-Metal-2,BTAP,13,ExteriorWall,Metal,2,Zone 8,5.46,Curtainwall: Glazed Spandrel,"1,11,60,162,6,50,51","gypsum wallboard 0.5 in thick
|
1227
|
+
galvanized LB studs, 16 ga x 3-5/8\"" W studs 16\"" O.C. x 10' H, incl galvanized top & bottom track, excl openings, headers, beams, bracing & bridging
|
1228
|
+
fibreglass batts, 6 in thick RSI3.35
|
1229
|
+
Kraft faced fiberglass, 3-1/2"" thick, 23"" wide, RSI2.29
|
1230
|
+
weather barrier, spunbonded polyethylene
|
1231
|
+
Spandrel glass 3/8"" plate
|
1232
|
+
Aluminum panel with 2 inches fibreglass
|
1233
|
+
",NECB_2011
|
1234
|
+
127,WALLS,BTAP-ExteriorWall-Metal-3,BTAP,14,ExteriorWall,Metal,3,Zone 4,3.18,Curtainwall: Sandwich Panel Spandrel,"1,11,43,56,6,52","gypsum wallboard 0.5 in thick
|
1235
|
+
galvanized LB studs, 16 ga x 3-5/8\"" W studs 16\"" O.C. x 10' H, incl galvanized top & bottom track, excl openings, headers, beams, bracing & bridging
|
1236
|
+
fibreglass batts, 6 in thick RSI 3.35
|
1237
|
+
Isoboard, 1"" thick, RSI .98
|
1238
|
+
weather barrier, spunbonded polyethylene
|
1239
|
+
22 gauge sheet metal galvanized with 2"" fibreglass, polyvinyl exterior finish
|
1240
|
+
",NECB_2011
|
1241
|
+
128,WALLS,BTAP-ExteriorWall-Metal-3,BTAP,14,ExteriorWall,Metal,3,Zone 5,3.6,Curtainwall: Sandwich Panel Spandrel,"1,11,43,6,52","gypsum wallboard 0.5 in thick
|
1242
|
+
galvanized LB studs, 16 ga x 3-5/8\"" W studs 16\"" O.C. x 10' H, incl galvanized top & bottom track, excl openings, headers, beams, bracing & bridging
|
1243
|
+
fibreglass batts, 6 in thick RSI 3.35
|
1244
|
+
weather barrier, spunbonded polyethylene
|
1245
|
+
22 gauge sheet metal galvanized with 2"" fibreglass, polyvinyl exterior finish
|
1246
|
+
",NECB_2011
|
1247
|
+
129,WALLS,BTAP-ExteriorWall-Metal-3,BTAP,14,ExteriorWall,Metal,3,Zone 6,4.05,Curtainwall: Sandwich Panel Spandrel,"1,11,60,6,52,64","gypsum wallboard 0.5 in thick
|
1248
|
+
galvanized LB studs, 16 ga x 3-5/8\"" W studs 16\"" O.C. x 10' H, incl galvanized top & bottom track, excl openings, headers, beams, bracing & bridging
|
1249
|
+
fibreglass batts, 6 in thick RSI3.35
|
1250
|
+
weather barrier, spunbonded polyethylene
|
1251
|
+
22 gauge sheet metal galvanized with 2"" fibreglass, polyvinyl exterior finish
|
1252
|
+
Polyurethane Foam 4.5"" thick, RSI 5.15 modifed to 5"" foaming RSI 5.67
|
1253
|
+
",NECB_2011
|
1254
|
+
130,WALLS,BTAP-ExteriorWall-Metal-3,BTAP,14,ExteriorWall,Metal,3,Zone 7A,4.76,Curtainwall: Sandwich Panel Spandrel,"1,11,60,6,52,64","gypsum wallboard 0.5 in thick
|
1255
|
+
galvanized LB studs, 16 ga x 3-5/8\"" W studs 16\"" O.C. x 10' H, incl galvanized top & bottom track, excl openings, headers, beams, bracing & bridging
|
1256
|
+
fibreglass batts, 6 in thick RSI3.35
|
1257
|
+
weather barrier, spunbonded polyethylene
|
1258
|
+
22 gauge sheet metal galvanized with 2"" fibreglass, polyvinyl exterior finish
|
1259
|
+
Polyurethane Foam 4.5"" thick, RSI 5.15 modifed to 5"" foaming RSI 5.67
|
1260
|
+
",NECB_2011
|
1261
|
+
131,WALLS,BTAP-ExteriorWall-Metal-3,BTAP,14,ExteriorWall,Metal,3,Zone 7B,4.76,Curtainwall: Sandwich Panel Spandrel,"1,11,60,6,52,64","gypsum wallboard 0.5 in thick
|
1262
|
+
galvanized LB studs, 16 ga x 3-5/8\"" W studs 16\"" O.C. x 10' H, incl galvanized top & bottom track, excl openings, headers, beams, bracing & bridging
|
1263
|
+
fibreglass batts, 6 in thick RSI3.35
|
1264
|
+
weather barrier, spunbonded polyethylene
|
1265
|
+
22 gauge sheet metal galvanized with 2"" fibreglass, polyvinyl exterior finish
|
1266
|
+
Polyurethane Foam 4.5"" thick, RSI 5.15 modifed to 5"" foaming RSI 5.67
|
1267
|
+
",NECB_2011
|
1268
|
+
132,WALLS,BTAP-ExteriorWall-Metal-3,BTAP,14,ExteriorWall,Metal,3,Zone 8,5.46,Curtainwall: Sandwich Panel Spandrel,"1,11,60,56,6,52,64","gypsum wallboard 0.5 in thick
|
1269
|
+
galvanized LB studs, 16 ga x 3-5/8\"" W studs 16\"" O.C. x 10' H, incl galvanized top & bottom track, excl openings, headers, beams, bracing & bridging
|
1270
|
+
fibreglass batts, 6 in thick RSI3.35
|
1271
|
+
Isoboard, 1"" thick, RSI .98
|
1272
|
+
weather barrier, spunbonded polyethylene
|
1273
|
+
22 gauge sheet metal galvanized with 2"" fibreglass, polyvinyl exterior finish
|
1274
|
+
Polyurethane Foam 4.5"" thick, RSI 5.15 modifed to 5"" foaming RSI 5.67
|
1275
|
+
",NECB_2011
|
1276
|
+
133,WALLS,BTAP-ExteriorWall-SteelFramed-1,BTAP,2,ExteriorWall,SteelFramed,1,Zone 4,3.18,"Steel Framed 2"" x6"", 16 "" O.C. with 1"" x 8"" T&G Redwood Siding","1,11,3,43,153,6,7,141,9,10","gypsum wallboard 0.5 in thick
|
1277
|
+
galvanized LB studs, 16 ga x 3-5/8\"" W studs 16\"" O.C. x 10' H, incl galvanized top & bottom track, excl openings, headers, beams, bracing & bridging
|
1278
|
+
polyethylene 4 ml vapour barrier
|
1279
|
+
fibreglass batts, 6 in thick RSI 3.35
|
1280
|
+
Fibreglasboard 1"" RSI 0.69
|
1281
|
+
weather barrier, spunbonded polyethylene
|
1282
|
+
wood siding T&G ""B"" grade
|
1283
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1284
|
+
waterproof sealer, 1 coat, sprayed
|
1285
|
+
stains, paints, 2 coats sprayed
|
1286
|
+
",NECB_2011
|
1287
|
+
134,WALLS,BTAP-ExteriorWall-SteelFramed-1,BTAP,2,ExteriorWall,SteelFramed,1,Zone 5,3.6,"Steel Framed 2"" x6"", 16 "" O.C. with 1"" x 8"" T&G Redwood Siding","1,11,3,53,5,56,6,7,141,9,10","gypsum wallboard 0.5 in thick
|
1288
|
+
galvanized LB studs, 16 ga x 3-5/8\"" W studs 16\"" O.C. x 10' H, incl galvanized top & bottom track, excl openings, headers, beams, bracing & bridging
|
1289
|
+
polyethylene 4 ml vapour barrier
|
1290
|
+
foil face fibreglass batts, 6 "" thick, 15"" wide, RSI 3.52
|
1291
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
1292
|
+
Isoboard, 1"" thick, RSI .98
|
1293
|
+
weather barrier, spunbonded polyethylene
|
1294
|
+
wood siding T&G ""B"" grade
|
1295
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1296
|
+
waterproof sealer, 1 coat, sprayed
|
1297
|
+
stains, paints, 2 coats sprayed
|
1298
|
+
",NECB_2011
|
1299
|
+
135,WALLS,BTAP-ExteriorWall-SteelFramed-1,BTAP,2,ExteriorWall,SteelFramed,1,Zone 6,4.05,"Steel Framed 2"" x6"", 16 "" O.C. with 1"" x 8"" T&G Redwood Siding","1,11,3,53,5,63,6,7,141,9,10","gypsum wallboard 0.5 in thick
|
1300
|
+
galvanized LB studs, 16 ga x 3-5/8\"" W studs 16\"" O.C. x 10' H, incl galvanized top & bottom track, excl openings, headers, beams, bracing & bridging
|
1301
|
+
polyethylene 4 ml vapour barrier
|
1302
|
+
foil face fibreglass batts, 6 "" thick, 15"" wide, RSI 3.52
|
1303
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
1304
|
+
Isoboard, 1.5"" thick, RSI 1.38
|
1305
|
+
weather barrier, spunbonded polyethylene
|
1306
|
+
wood siding T&G ""B"" grade
|
1307
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1308
|
+
waterproof sealer, 1 coat, sprayed
|
1309
|
+
stains, paints, 2 coats sprayed
|
1310
|
+
",NECB_2011
|
1311
|
+
136,WALLS,BTAP-ExteriorWall-SteelFramed-1,BTAP,2,ExteriorWall,SteelFramed,1,Zone 7A,4.76,"Steel Framed 2"" x6"", 16 "" O.C. with 1"" x 8"" T&G Redwood Siding","1,11,3,53,5,67,6,7,141,9,10","gypsum wallboard 0.5 in thick
|
1312
|
+
galvanized LB studs, 16 ga x 3-5/8\"" W studs 16\"" O.C. x 10' H, incl galvanized top & bottom track, excl openings, headers, beams, bracing & bridging
|
1313
|
+
polyethylene 4 ml vapour barrier
|
1314
|
+
foil face fibreglass batts, 6 "" thick, 15"" wide, RSI 3.52
|
1315
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
1316
|
+
Isoboard sheathing, 2"" thick RSI 1.93
|
1317
|
+
weather barrier, spunbonded polyethylene
|
1318
|
+
wood siding T&G ""B"" grade
|
1319
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1320
|
+
waterproof sealer, 1 coat, sprayed
|
1321
|
+
stains, paints, 2 coats sprayed
|
1322
|
+
",NECB_2011
|
1323
|
+
137,WALLS,BTAP-ExteriorWall-SteelFramed-1,BTAP,2,ExteriorWall,SteelFramed,1,Zone 7B,4.76,"Steel Framed 2"" x6"", 16 "" O.C. with 1"" x 8"" T&G Redwood Siding","1,11,3,53,5,67,6,7,141,9,10","gypsum wallboard 0.5 in thick
|
1324
|
+
galvanized LB studs, 16 ga x 3-5/8\"" W studs 16\"" O.C. x 10' H, incl galvanized top & bottom track, excl openings, headers, beams, bracing & bridging
|
1325
|
+
polyethylene 4 ml vapour barrier
|
1326
|
+
foil face fibreglass batts, 6 "" thick, 15"" wide, RSI 3.52
|
1327
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
1328
|
+
Isoboard sheathing, 2"" thick RSI 1.93
|
1329
|
+
weather barrier, spunbonded polyethylene
|
1330
|
+
wood siding T&G ""B"" grade
|
1331
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1332
|
+
waterproof sealer, 1 coat, sprayed
|
1333
|
+
stains, paints, 2 coats sprayed
|
1334
|
+
",NECB_2011
|
1335
|
+
138,WALLS,BTAP-ExteriorWall-SteelFramed-1,BTAP,2,ExteriorWall,SteelFramed,1,Zone 8,5.46,"Steel Framed 2"" x6"", 16 "" O.C. with 1"" x 8"" T&G Redwood Siding","1,11,3,53,5,56,67,6,7,141,9,10","gypsum wallboard 0.5 in thick
|
1336
|
+
galvanized LB studs, 16 ga x 3-5/8\"" W studs 16\"" O.C. x 10' H, incl galvanized top & bottom track, excl openings, headers, beams, bracing & bridging
|
1337
|
+
polyethylene 4 ml vapour barrier
|
1338
|
+
foil face fibreglass batts, 6 "" thick, 15"" wide, RSI 3.52
|
1339
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
1340
|
+
Isoboard, 1"" thick, RSI .98
|
1341
|
+
Isoboard sheathing, 2"" thick RSI 1.93
|
1342
|
+
weather barrier, spunbonded polyethylene
|
1343
|
+
wood siding T&G ""B"" grade
|
1344
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1345
|
+
waterproof sealer, 1 coat, sprayed
|
1346
|
+
stains, paints, 2 coats sprayed
|
1347
|
+
",NECB_2011
|
1348
|
+
139,WALLS,BTAP-ExteriorWall-WoodFramed-1,BTAP,1,ExteriorWall,WoodFramed,1,Zone 4,3.18,"Wood Framed 2"" x6"", 16 "" O.C. with 1"" x 8"" T&G Redwood Siding","1,138,139,140,141,3,4,6,7,9,10","gypsum wallboard 0.5 in thick
|
1349
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
1350
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
1351
|
+
Pre-formed joint seals, backer rod, polyethylene, 1/4\"" dia""
|
1352
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1353
|
+
polyethylene 4 ml vapour barrier
|
1354
|
+
foil face fibreglass batts, 5"" thick, 15"" wide, RSI 3.36
|
1355
|
+
weather barrier, spunbonded polyethylene
|
1356
|
+
wood siding T&G ""B"" grade
|
1357
|
+
waterproof sealer, 1 coat, sprayed
|
1358
|
+
stains, paints, 2 coats sprayed
|
1359
|
+
",NECB_2011
|
1360
|
+
140,WALLS,BTAP-ExteriorWall-WoodFramed-1,BTAP,1,ExteriorWall,WoodFramed,1,Zone 5,3.6,"Wood Framed 2"" x6"", 16 "" O.C. with 1"" x 8"" T&G Redwood Siding","1,138,139,140,141,3,53,5,153,6,7,141,9,10","gypsum wallboard 0.5 in thick
|
1361
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
1362
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
1363
|
+
Pre-formed joint seals, backer rod, polyethylene, 1/4\"" dia""
|
1364
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1365
|
+
polyethylene 4 ml vapour barrier
|
1366
|
+
foil face fibreglass batts, 6 "" thick, 15"" wide, RSI 3.52
|
1367
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
1368
|
+
Fibreglasboard 1"" RSI 0.69
|
1369
|
+
weather barrier, spunbonded polyethylene
|
1370
|
+
wood siding T&G ""B"" grade
|
1371
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1372
|
+
waterproof sealer, 1 coat, sprayed
|
1373
|
+
stains, paints, 2 coats sprayed
|
1374
|
+
",NECB_2011
|
1375
|
+
141,WALLS,BTAP-ExteriorWall-WoodFramed-1,BTAP,1,ExteriorWall,WoodFramed,1,Zone 6,4.05,"Wood Framed 2"" x6"", 16 "" O.C. with 1"" x 8"" T&G Redwood Siding","1,138,139,140,141,3,53,5,153,6,7,141,9,10","gypsum wallboard 0.5 in thick
|
1376
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
1377
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
1378
|
+
Pre-formed joint seals, backer rod, polyethylene, 1/4\"" dia""
|
1379
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1380
|
+
polyethylene 4 ml vapour barrier
|
1381
|
+
foil face fibreglass batts, 6 "" thick, 15"" wide, RSI 3.52
|
1382
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
1383
|
+
Fibreglasboard 1"" RSI 0.69
|
1384
|
+
weather barrier, spunbonded polyethylene
|
1385
|
+
wood siding T&G ""B"" grade
|
1386
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1387
|
+
waterproof sealer, 1 coat, sprayed
|
1388
|
+
stains, paints, 2 coats sprayed
|
1389
|
+
",NECB_2011
|
1390
|
+
142,WALLS,BTAP-ExteriorWall-WoodFramed-1,BTAP,1,ExteriorWall,WoodFramed,1,Zone 7A,4.76,"Wood Framed 2"" x6"", 16 "" O.C. with 1"" x 8"" T&G Redwood Siding","1,138,139,140,141,3,53,5,153,153,6,7,141,9,10","gypsum wallboard 0.5 in thick
|
1391
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
1392
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
1393
|
+
Pre-formed joint seals, backer rod, polyethylene, 1/4\"" dia""
|
1394
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1395
|
+
polyethylene 4 ml vapour barrier
|
1396
|
+
foil face fibreglass batts, 6 "" thick, 15"" wide, RSI 3.52
|
1397
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
1398
|
+
Fibreglasboard 1"" RSI 0.69
|
1399
|
+
Fibreglasboard 1"" RSI 0.69
|
1400
|
+
weather barrier, spunbonded polyethylene
|
1401
|
+
wood siding T&G ""B"" grade
|
1402
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1403
|
+
waterproof sealer, 1 coat, sprayed
|
1404
|
+
stains, paints, 2 coats sprayed
|
1405
|
+
",NECB_2011
|
1406
|
+
143,WALLS,BTAP-ExteriorWall-WoodFramed-1,BTAP,1,ExteriorWall,WoodFramed,1,Zone 7B,4.76,"Wood Framed 2"" x6"", 16 "" O.C. with 1"" x 8"" T&G Redwood Siding","1,138,139,140,141,3,53,5,153,153,6,7,141,9,10","gypsum wallboard 0.5 in thick
|
1407
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
1408
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
1409
|
+
Pre-formed joint seals, backer rod, polyethylene, 1/4\"" dia""
|
1410
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1411
|
+
polyethylene 4 ml vapour barrier
|
1412
|
+
foil face fibreglass batts, 6 "" thick, 15"" wide, RSI 3.52
|
1413
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
1414
|
+
Fibreglasboard 1"" RSI 0.69
|
1415
|
+
Fibreglasboard 1"" RSI 0.69
|
1416
|
+
weather barrier, spunbonded polyethylene
|
1417
|
+
wood siding T&G ""B"" grade
|
1418
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1419
|
+
waterproof sealer, 1 coat, sprayed
|
1420
|
+
stains, paints, 2 coats sprayed
|
1421
|
+
",NECB_2011
|
1422
|
+
144,WALLS,BTAP-ExteriorWall-WoodFramed-1,BTAP,1,ExteriorWall,WoodFramed,1,Zone 8,5.46,"Wood Framed 2"" x6"", 16 "" O.C. with 1"" x 8"" T&G Redwood Siding","1,138,139,140,141,3,53,5,153,153,153,6,7,141,9,10","gypsum wallboard 0.5 in thick
|
1423
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
1424
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
1425
|
+
Pre-formed joint seals, backer rod, polyethylene, 1/4\"" dia""
|
1426
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1427
|
+
polyethylene 4 ml vapour barrier
|
1428
|
+
foil face fibreglass batts, 6 "" thick, 15"" wide, RSI 3.52
|
1429
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
1430
|
+
Fibreglasboard 1"" RSI 0.69
|
1431
|
+
Fibreglasboard 1"" RSI 0.69
|
1432
|
+
Fibreglasboard 1"" RSI 0.69
|
1433
|
+
weather barrier, spunbonded polyethylene
|
1434
|
+
wood siding T&G ""B"" grade
|
1435
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1436
|
+
waterproof sealer, 1 coat, sprayed
|
1437
|
+
stains, paints, 2 coats sprayed
|
1438
|
+
",NECB_2011
|
1439
|
+
145,WALLS,BTAP-ExteriorWall-WoodFramed-2,BTAP,3,ExteriorWall,WoodFramed,2,Zone 4,3.18,"Wood Framed 2"" x6"", 16 "" O.C. with 1"" EPS EIFS","1,138,3,30,5,12","gypsum wallboard 0.5 in thick
|
1440
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
1441
|
+
polyethylene 4 ml vapour barrier
|
1442
|
+
fibreglass batts, 3.5 in thick RSI2.29
|
1443
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
1444
|
+
Polymer EIFS with 2 in EPS and finish
|
1445
|
+
",NECB_2011
|
1446
|
+
146,WALLS,BTAP-ExteriorWall-WoodFramed-2,BTAP,3,ExteriorWall,WoodFramed,2,Zone 5,3.6,"Wood Framed 2"" x6"", 16 "" O.C. with 1"" EPS EIFS","1,138,3,4,5,12","gypsum wallboard 0.5 in thick
|
1447
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
1448
|
+
polyethylene 4 ml vapour barrier
|
1449
|
+
foil face fibreglass batts, 5"" thick, 15"" wide, RSI 3.36
|
1450
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
1451
|
+
Polymer EIFS with 2 in EPS and finish
|
1452
|
+
",NECB_2011
|
1453
|
+
147,WALLS,BTAP-ExteriorWall-WoodFramed-2,BTAP,3,ExteriorWall,WoodFramed,2,Zone 6,4.05,"Wood Framed 2"" x6"", 16 "" O.C. with 1"" EPS EIFS","1,138,3,4,5,12","gypsum wallboard 0.5 in thick
|
1454
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
1455
|
+
polyethylene 4 ml vapour barrier
|
1456
|
+
foil face fibreglass batts, 5"" thick, 15"" wide, RSI 3.36
|
1457
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
1458
|
+
Polymer EIFS with 2 in EPS and finish
|
1459
|
+
",NECB_2011
|
1460
|
+
148,WALLS,BTAP-ExteriorWall-WoodFramed-2,BTAP,3,ExteriorWall,WoodFramed,2,Zone 7A,4.76,"Wood Framed 2"" x6"", 16 "" O.C. with 1"" EPS EIFS","1,138,3,53,5,12","gypsum wallboard 0.5 in thick
|
1461
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
1462
|
+
polyethylene 4 ml vapour barrier
|
1463
|
+
foil face fibreglass batts, 6 "" thick, 15"" wide, RSI 3.52
|
1464
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
1465
|
+
Polymer EIFS with 2 in EPS and finish
|
1466
|
+
",NECB_2011
|
1467
|
+
149,WALLS,BTAP-ExteriorWall-WoodFramed-2,BTAP,3,ExteriorWall,WoodFramed,2,Zone 7B,4.76,"Wood Framed 2"" x6"", 16 "" O.C. with 1"" EPS EIFS","1,138,3,53,5,12","gypsum wallboard 0.5 in thick
|
1468
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
1469
|
+
polyethylene 4 ml vapour barrier
|
1470
|
+
foil face fibreglass batts, 6 "" thick, 15"" wide, RSI 3.52
|
1471
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
1472
|
+
Polymer EIFS with 2 in EPS and finish
|
1473
|
+
",NECB_2011
|
1474
|
+
150,WALLS,BTAP-ExteriorWall-WoodFramed-2,BTAP,3,ExteriorWall,WoodFramed,2,Zone 8,5.46,"Wood Framed 2"" x6"", 16 "" O.C. with 1"" EPS EIFS","1,138,3,53,100,5,12","gypsum wallboard 0.5 in thick
|
1475
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
1476
|
+
polyethylene 4 ml vapour barrier
|
1477
|
+
foil face fibreglass batts, 6 "" thick, 15"" wide, RSI 3.52
|
1478
|
+
Isoboard, 1.5 in thick RSI 1.48
|
1479
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
1480
|
+
Polymer EIFS with 2 in EPS and finish
|
1481
|
+
",NECB_2011
|
1482
|
+
151,WALLS,BTAP-ExteriorWall-WoodFramed-3,BTAP,4,ExteriorWall,WoodFramed,3,Zone 4,3.18,"Wood Framed 2"" x6"", 16 "" O.C. with 1 "" x 8"" vinyl siding","1,138,3,4,5,6,14,141,15","gypsum wallboard 0.5 in thick
|
1483
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
1484
|
+
polyethylene 4 ml vapour barrier
|
1485
|
+
foil face fibreglass batts, 5"" thick, 15"" wide, RSI 3.36
|
1486
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
1487
|
+
weather barrier, spunbonded polyethylene
|
1488
|
+
vinyl siding, clapboard profile, woodgrain texture, 0.048 "" thick, 8"" width
|
1489
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1490
|
+
aluminum flashing, mill finish. 0.013 "" thick
|
1491
|
+
",NECB_2011
|
1492
|
+
152,WALLS,BTAP-ExteriorWall-WoodFramed-3,BTAP,4,ExteriorWall,WoodFramed,3,Zone 5,3.6,"Wood Framed 2"" x6"", 16 "" O.C. with 1 "" x 8"" vinyl siding","1,138,3,53,5,6,14,141,15","gypsum wallboard 0.5 in thick
|
1493
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
1494
|
+
polyethylene 4 ml vapour barrier
|
1495
|
+
foil face fibreglass batts, 6 "" thick, 15"" wide, RSI 3.52
|
1496
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
1497
|
+
weather barrier, spunbonded polyethylene
|
1498
|
+
vinyl siding, clapboard profile, woodgrain texture, 0.048 "" thick, 8"" width
|
1499
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1500
|
+
aluminum flashing, mill finish. 0.013 "" thick
|
1501
|
+
",NECB_2011
|
1502
|
+
153,WALLS,BTAP-ExteriorWall-WoodFramed-3,BTAP,4,ExteriorWall,WoodFramed,3,Zone 6,4.05,"Wood Framed 2"" x6"", 16 "" O.C. with 1 "" x 8"" vinyl siding","1,138,3,53,5,54,6,14,141,15","gypsum wallboard 0.5 in thick
|
1503
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
1504
|
+
polyethylene 4 ml vapour barrier
|
1505
|
+
foil face fibreglass batts, 6 "" thick, 15"" wide, RSI 3.52
|
1506
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
1507
|
+
0.5"" Isoboard, 4 x 8 sheet, foil faced (RSI 0.48)
|
1508
|
+
weather barrier, spunbonded polyethylene
|
1509
|
+
vinyl siding, clapboard profile, woodgrain texture, 0.048 "" thick, 8"" width
|
1510
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1511
|
+
aluminum flashing, mill finish. 0.013 "" thick
|
1512
|
+
",NECB_2011
|
1513
|
+
154,WALLS,BTAP-ExteriorWall-WoodFramed-3,BTAP,4,ExteriorWall,WoodFramed,3,Zone 7A,4.76,"Wood Framed 2"" x6"", 16 "" O.C. with 1 "" x 8"" vinyl siding","1,138,3,53,5,56,6,14,141,15","gypsum wallboard 0.5 in thick
|
1514
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
1515
|
+
polyethylene 4 ml vapour barrier
|
1516
|
+
foil face fibreglass batts, 6 "" thick, 15"" wide, RSI 3.52
|
1517
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
1518
|
+
Isoboard, 1"" thick, RSI .98
|
1519
|
+
weather barrier, spunbonded polyethylene
|
1520
|
+
vinyl siding, clapboard profile, woodgrain texture, 0.048 "" thick, 8"" width
|
1521
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1522
|
+
aluminum flashing, mill finish. 0.013 "" thick
|
1523
|
+
",NECB_2011
|
1524
|
+
155,WALLS,BTAP-ExteriorWall-WoodFramed-3,BTAP,4,ExteriorWall,WoodFramed,3,Zone 7B,4.76,"Wood Framed 2"" x6"", 16 "" O.C. with 1 "" x 8"" vinyl siding","1,138,3,53,5,56,6,14,141,15","gypsum wallboard 0.5 in thick
|
1525
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
1526
|
+
polyethylene 4 ml vapour barrier
|
1527
|
+
foil face fibreglass batts, 6 "" thick, 15"" wide, RSI 3.52
|
1528
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
1529
|
+
Isoboard, 1"" thick, RSI .98
|
1530
|
+
weather barrier, spunbonded polyethylene
|
1531
|
+
vinyl siding, clapboard profile, woodgrain texture, 0.048 "" thick, 8"" width
|
1532
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1533
|
+
aluminum flashing, mill finish. 0.013 "" thick
|
1534
|
+
",NECB_2011
|
1535
|
+
156,WALLS,BTAP-ExteriorWall-WoodFramed-3,BTAP,4,ExteriorWall,WoodFramed,3,Zone 8,5.46,"Wood Framed 2"" x6"", 16 "" O.C. with 1 "" x 8"" vinyl siding","1,138,3,53,5,67,6,14,141,15","gypsum wallboard 0.5 in thick
|
1536
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
1537
|
+
polyethylene 4 ml vapour barrier
|
1538
|
+
foil face fibreglass batts, 6 "" thick, 15"" wide, RSI 3.52
|
1539
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
1540
|
+
Isoboard sheathing, 2"" thick RSI 1.93
|
1541
|
+
weather barrier, spunbonded polyethylene
|
1542
|
+
vinyl siding, clapboard profile, woodgrain texture, 0.048 "" thick, 8"" width
|
1543
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1544
|
+
aluminum flashing, mill finish. 0.013 "" thick
|
1545
|
+
",NECB_2011
|
1546
|
+
157,WALLS,BTAP-ExteriorWall-WoodFramed-4,BTAP,5,ExteriorWall,WoodFramed,4,Zone 4,3.18,"Wood Framed 2"" x6"", 16 "" O.C. with 12"" painted metal siding","1,138,3,4,5,6,16,17,18,141","gypsum wallboard 0.5 in thick
|
1547
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
1548
|
+
polyethylene 4 ml vapour barrier
|
1549
|
+
foil face fibreglass batts, 5"" thick, 15"" wide, RSI 3.36
|
1550
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
1551
|
+
weather barrier, spunbonded polyethylene
|
1552
|
+
metal decking strips, galvanized, 18 gauge
|
1553
|
+
10 yr finish metal siding, 24 gauge, 0.0239 "" thick with fasteners
|
1554
|
+
aluminum closure strips, mill finish. 0.032 "" thick
|
1555
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1556
|
+
",NECB_2011
|
1557
|
+
158,WALLS,BTAP-ExteriorWall-WoodFramed-4,BTAP,5,ExteriorWall,WoodFramed,4,Zone 5,3.6,"Wood Framed 2"" x6"", 16 "" O.C. with 12"" painted metal siding","1,138,3,53,5,6,16,17,18,141","gypsum wallboard 0.5 in thick
|
1558
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
1559
|
+
polyethylene 4 ml vapour barrier
|
1560
|
+
foil face fibreglass batts, 6 "" thick, 15"" wide, RSI 3.52
|
1561
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
1562
|
+
weather barrier, spunbonded polyethylene
|
1563
|
+
metal decking strips, galvanized, 18 gauge
|
1564
|
+
10 yr finish metal siding, 24 gauge, 0.0239 "" thick with fasteners
|
1565
|
+
aluminum closure strips, mill finish. 0.032 "" thick
|
1566
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1567
|
+
",NECB_2011
|
1568
|
+
159,WALLS,BTAP-ExteriorWall-WoodFramed-4,BTAP,5,ExteriorWall,WoodFramed,4,Zone 6,4.05,"Wood Framed 2"" x6"", 16 "" O.C. with 12"" painted metal siding","1,138,3,43,5,56,6,16,17,18,141","gypsum wallboard 0.5 in thick
|
1569
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
1570
|
+
polyethylene 4 ml vapour barrier
|
1571
|
+
fibreglass batts, 6 in thick RSI 3.35
|
1572
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
1573
|
+
Isoboard, 1"" thick, RSI .98
|
1574
|
+
weather barrier, spunbonded polyethylene
|
1575
|
+
metal decking strips, galvanized, 18 gauge
|
1576
|
+
10 yr finish metal siding, 24 gauge, 0.0239 "" thick with fasteners
|
1577
|
+
aluminum closure strips, mill finish. 0.032 "" thick
|
1578
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1579
|
+
",NECB_2011
|
1580
|
+
160,WALLS,BTAP-ExteriorWall-WoodFramed-4,BTAP,5,ExteriorWall,WoodFramed,4,Zone 7A,4.76,"Wood Framed 2"" x6"", 16 "" O.C. with 12"" painted metal siding","1,138,3,53,5,56,6,16,17,18,141","gypsum wallboard 0.5 in thick
|
1581
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
1582
|
+
polyethylene 4 ml vapour barrier
|
1583
|
+
foil face fibreglass batts, 6 "" thick, 15"" wide, RSI 3.52
|
1584
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
1585
|
+
Isoboard, 1"" thick, RSI .98
|
1586
|
+
weather barrier, spunbonded polyethylene
|
1587
|
+
metal decking strips, galvanized, 18 gauge
|
1588
|
+
10 yr finish metal siding, 24 gauge, 0.0239 "" thick with fasteners
|
1589
|
+
aluminum closure strips, mill finish. 0.032 "" thick
|
1590
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1591
|
+
",NECB_2011
|
1592
|
+
161,WALLS,BTAP-ExteriorWall-WoodFramed-4,BTAP,5,ExteriorWall,WoodFramed,4,Zone 7B,4.76,"Wood Framed 2"" x6"", 16 "" O.C. with 12"" painted metal siding","1,138,3,53,5,56,6,16,17,18,141","gypsum wallboard 0.5 in thick
|
1593
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
1594
|
+
polyethylene 4 ml vapour barrier
|
1595
|
+
foil face fibreglass batts, 6 "" thick, 15"" wide, RSI 3.52
|
1596
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
1597
|
+
Isoboard, 1"" thick, RSI .98
|
1598
|
+
weather barrier, spunbonded polyethylene
|
1599
|
+
metal decking strips, galvanized, 18 gauge
|
1600
|
+
10 yr finish metal siding, 24 gauge, 0.0239 "" thick with fasteners
|
1601
|
+
aluminum closure strips, mill finish. 0.032 "" thick
|
1602
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1603
|
+
",NECB_2011
|
1604
|
+
162,WALLS,BTAP-ExteriorWall-WoodFramed-4,BTAP,5,ExteriorWall,WoodFramed,4,Zone 8,5.46,"Wood Framed 2"" x6"", 16 "" O.C. with 12"" painted metal siding","1,138,3,53,5,67,6,16,17,18,141","gypsum wallboard 0.5 in thick
|
1605
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
1606
|
+
polyethylene 4 ml vapour barrier
|
1607
|
+
foil face fibreglass batts, 6 "" thick, 15"" wide, RSI 3.52
|
1608
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
1609
|
+
Isoboard sheathing, 2"" thick RSI 1.93
|
1610
|
+
weather barrier, spunbonded polyethylene
|
1611
|
+
metal decking strips, galvanized, 18 gauge
|
1612
|
+
10 yr finish metal siding, 24 gauge, 0.0239 "" thick with fasteners
|
1613
|
+
aluminum closure strips, mill finish. 0.032 "" thick
|
1614
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1615
|
+
",NECB_2011
|
1616
|
+
163,WALLS,BTAP-ExteriorWall-WoodFramed-5,BTAP,6,ExteriorWall,WoodFramed,5,Zone 4,3.18,"Wood Framed 2"" x6"", 16 "" O.C. with 4"" brick standard face veneer","1,138,3,43,5,6,20,21,139,141","gypsum wallboard 0.5 in thick
|
1617
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
1618
|
+
polyethylene 4 ml vapour barrier
|
1619
|
+
fibreglass batts, 6 in thick RSI 3.35
|
1620
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
1621
|
+
weather barrier, spunbonded polyethylene
|
1622
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
1623
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
1624
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
1625
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1626
|
+
",NECB_2011
|
1627
|
+
164,WALLS,BTAP-ExteriorWall-WoodFramed-5,BTAP,6,ExteriorWall,WoodFramed,5,Zone 5,3.6,"Wood Framed 2"" x6"", 16 "" O.C. with 4"" brick standard face veneer","1,138,3,53,5,6,20,21,139,141","gypsum wallboard 0.5 in thick
|
1628
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
1629
|
+
polyethylene 4 ml vapour barrier
|
1630
|
+
foil face fibreglass batts, 6 "" thick, 15"" wide, RSI 3.52
|
1631
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
1632
|
+
weather barrier, spunbonded polyethylene
|
1633
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
1634
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
1635
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
1636
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1637
|
+
",NECB_2011
|
1638
|
+
165,WALLS,BTAP-ExteriorWall-WoodFramed-5,BTAP,6,ExteriorWall,WoodFramed,5,Zone 6,4.05,"Wood Framed 2"" x6"", 16 "" O.C. with 4"" brick standard face veneer","1,138,3,53,5,158,6,20,21,139,141","gypsum wallboard 0.5 in thick
|
1639
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
1640
|
+
polyethylene 4 ml vapour barrier
|
1641
|
+
foil face fibreglass batts, 6 "" thick, 15"" wide, RSI 3.52
|
1642
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
1643
|
+
XPS, 3/4"" RSI 0.501
|
1644
|
+
weather barrier, spunbonded polyethylene
|
1645
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
1646
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
1647
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
1648
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1649
|
+
",NECB_2011
|
1650
|
+
166,WALLS,BTAP-ExteriorWall-WoodFramed-5,BTAP,6,ExteriorWall,WoodFramed,5,Zone 7A,4.76,"Wood Framed 2"" x6"", 16 "" O.C. with 4"" brick standard face veneer","1,138,3,53,5,150,158,6,20,21,139,141","gypsum wallboard 0.5 in thick
|
1651
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
1652
|
+
polyethylene 4 ml vapour barrier
|
1653
|
+
foil face fibreglass batts, 6 "" thick, 15"" wide, RSI 3.52
|
1654
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
1655
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
1656
|
+
XPS, 3/4"" RSI 0.501
|
1657
|
+
weather barrier, spunbonded polyethylene
|
1658
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
1659
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
1660
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
1661
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1662
|
+
",NECB_2011
|
1663
|
+
168,WALLS,BTAP-ExteriorWall-WoodFramed-5,BTAP,6,ExteriorWall,WoodFramed,5,Zone 8,5.46,"Wood Framed 2"" x6"", 16 "" O.C. with 4"" brick standard face veneer","1,138,3,53,5,158,40,6,20,21,139,141","gypsum wallboard 0.5 in thick
|
1664
|
+
Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate
|
1665
|
+
polyethylene 4 ml vapour barrier
|
1666
|
+
foil face fibreglass batts, 6 "" thick, 15"" wide, RSI 3.52
|
1667
|
+
plywood sheathing, CDX, 0.5 in, pneumatic nailer
|
1668
|
+
XPS, 3/4"" RSI 0.501
|
1669
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
1670
|
+
weather barrier, spunbonded polyethylene
|
1671
|
+
Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar
|
1672
|
+
Lintel angle, structural, unpainted, under 500 lb., shop fabricated
|
1673
|
+
Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends
|
1674
|
+
Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""
|
1675
|
+
",NECB_2011
|
1676
|
+
169,SLAB,BTAP-GroundContactFloor-Unheated-1,BTAP,1,GroundContactFloor,Unheated,1,Zone 4,1.32,"6 "" Concrete Reinforced Slab on Grade","123,124,125,126,127,128,129,130,131,132,133","Concrete forms, wooden, erecting, bracing, stripping, cleaning
|
1677
|
+
Expansion joint, premolded bituminous fiber
|
1678
|
+
Welded wire, 6 x 6 sheets, 30 lbs/ft2
|
1679
|
+
Structural concrete, ready mix 3500 psi, local aggregate, Type 1 Portland cement, no additives
|
1680
|
+
Structural concrete, placing, slab on grade, direct chute, over 6\"" thick, includes leveling
|
1681
|
+
Concrete finishing, specified Random Access Floors ACI Classes 1, 2, 3 & 4
|
1682
|
+
Concrete surface treatment, sprayed membrane
|
1683
|
+
Vapur barrier, polyethylene 6 mil
|
1684
|
+
Fine grading, finish grading, small area, to be paved with grader
|
1685
|
+
Fill, gravel fill, compacted, under floor slabs, 4\"" deep
|
1686
|
+
Isoboard, 38 mm RSI 1.44
|
1687
|
+
",NECB_2011
|
1688
|
+
174,SLAB,BTAP-GroundContactFloor-Unheated-1,BTAP,1,GroundContactFloor,Unheated,1,Zone 8,2.64,"6 "" Concrete Reinforced Slab on Grade","123,124,125,126,127,128,129,130,131,132,134","Concrete forms, wooden, erecting, bracing, stripping, cleaning
|
1689
|
+
Expansion joint, premolded bituminous fiber
|
1690
|
+
Welded wire, 6 x 6 sheets, 30 lbs/ft2
|
1691
|
+
Structural concrete, ready mix 3500 psi, local aggregate, Type 1 Portland cement, no additives
|
1692
|
+
Structural concrete, placing, slab on grade, direct chute, over 6\"" thick, includes leveling
|
1693
|
+
Concrete finishing, specified Random Access Floors ACI Classes 1, 2, 3 & 4
|
1694
|
+
Concrete surface treatment, sprayed membrane
|
1695
|
+
Vapur barrier, polyethylene 6 mil
|
1696
|
+
Fine grading, finish grading, small area, to be paved with grader
|
1697
|
+
Fill, gravel fill, compacted, under floor slabs, 4\"" deep
|
1698
|
+
XPS, 3"" 2.64
|
1699
|
+
",NECB_2011
|
1700
|
+
175,BG-ROOF,BTAP-GroundContactRoof-Mass-1,BTAP,1,GroundContactRoof,Mass,1,Zone 4,1.76,"Cast in Place Concrete Slab Roof , 7.5"" thick, 200 PSI with Exterior Insulation","40,109,110,111,112,113,144,143,114","XPS, 25 PSI, 2"" RSI 1.76
|
1701
|
+
Roof Insulation fastening, 4"" screws
|
1702
|
+
C.I.P. forms elevated slab floor hung from steel beams, including shoring, erection, bracing
|
1703
|
+
C.I.P. forms elevated slab edge forms, including shoring, erection, bracing
|
1704
|
+
Reinforcing steel for elevated slabs and ceilings/roofa, grade 60, all assembly and accessories
|
1705
|
+
Structural concrete, 3000 PSI, complete delivered and pum,ped in place
|
1706
|
+
Structural concrete, placing, elevated slab, pumped, 6\"" to 10\"" thick, includes leveling (strike off) & consolidation
|
1707
|
+
Concrete finishing, specified Random Access Floors ACI Classes 1, 2, 3 & 4,
|
1708
|
+
Concrete surface treatment, curing, sprayed membrane compound
|
1709
|
+
",NECB_2011
|
1710
|
+
176,BG-ROOF,BTAP-GroundContactRoof-Mass-1,BTAP,1,GroundContactRoof,Mass,1,Zone 5,2.64,"Cast in Place Concrete Slab Roof , 7.5"" thick, 200 PSI with Exterior Insulation","80,109,110,111,112,113,144,143,114","XPS, 25 PSI, 3"" RSI 2.64
|
1711
|
+
Roof Insulation fastening, 4"" screws
|
1712
|
+
C.I.P. forms elevated slab floor hung from steel beams, including shoring, erection, bracing
|
1713
|
+
C.I.P. forms elevated slab edge forms, including shoring, erection, bracing
|
1714
|
+
Reinforcing steel for elevated slabs and ceilings/roofa, grade 60, all assembly and accessories
|
1715
|
+
Structural concrete, 3000 PSI, complete delivered and pum,ped in place
|
1716
|
+
Structural concrete, placing, elevated slab, pumped, 6\"" to 10\"" thick, includes leveling (strike off) & consolidation
|
1717
|
+
Concrete finishing, specified Random Access Floors ACI Classes 1, 2, 3 & 4,
|
1718
|
+
Concrete surface treatment, curing, sprayed membrane compound
|
1719
|
+
",NECB_2011
|
1720
|
+
177,BG-ROOF,BTAP-GroundContactRoof-Mass-1,BTAP,1,GroundContactRoof,Mass,1,Zone 6,3.52,"Cast in Place Concrete Slab Roof , 7.5"" thick, 200 PSI with Exterior Insulation","40,40,109,110,111,112,113,144,143,114","XPS, 25 PSI, 2"" RSI 1.76
|
1721
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
1722
|
+
Roof Insulation fastening, 4"" screws
|
1723
|
+
C.I.P. forms elevated slab floor hung from steel beams, including shoring, erection, bracing
|
1724
|
+
C.I.P. forms elevated slab edge forms, including shoring, erection, bracing
|
1725
|
+
Reinforcing steel for elevated slabs and ceilings/roofa, grade 60, all assembly and accessories
|
1726
|
+
Structural concrete, 3000 PSI, complete delivered and pum,ped in place
|
1727
|
+
Structural concrete, placing, elevated slab, pumped, 6\"" to 10\"" thick, includes leveling (strike off) & consolidation
|
1728
|
+
Concrete finishing, specified Random Access Floors ACI Classes 1, 2, 3 & 4,
|
1729
|
+
Concrete surface treatment, curing, sprayed membrane compound
|
1730
|
+
",NECB_2011
|
1731
|
+
178,BG-ROOF,BTAP-GroundContactRoof-Mass-1,BTAP,1,GroundContactRoof,Mass,1,Zone 7A,3.52,"Cast in Place Concrete Slab Roof , 7.5"" thick, 200 PSI with Exterior Insulation","40,40,109,110,111,112,113,144,143,114","XPS, 25 PSI, 2"" RSI 1.76
|
1732
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
1733
|
+
Roof Insulation fastening, 4"" screws
|
1734
|
+
C.I.P. forms elevated slab floor hung from steel beams, including shoring, erection, bracing
|
1735
|
+
C.I.P. forms elevated slab edge forms, including shoring, erection, bracing
|
1736
|
+
Reinforcing steel for elevated slabs and ceilings/roofa, grade 60, all assembly and accessories
|
1737
|
+
Structural concrete, 3000 PSI, complete delivered and pum,ped in place
|
1738
|
+
Structural concrete, placing, elevated slab, pumped, 6\"" to 10\"" thick, includes leveling (strike off) & consolidation
|
1739
|
+
Concrete finishing, specified Random Access Floors ACI Classes 1, 2, 3 & 4,
|
1740
|
+
Concrete surface treatment, curing, sprayed membrane compound
|
1741
|
+
",NECB_2011
|
1742
|
+
179,BG-ROOF,BTAP-GroundContactRoof-Mass-1,BTAP,1,GroundContactRoof,Mass,1,Zone 7B,3.52,"Cast in Place Concrete Slab Roof , 7.5"" thick, 200 PSI with Exterior Insulation","40,40,109,110,111,112,113,144,143,114","XPS, 25 PSI, 2"" RSI 1.76
|
1743
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
1744
|
+
Roof Insulation fastening, 4"" screws
|
1745
|
+
C.I.P. forms elevated slab floor hung from steel beams, including shoring, erection, bracing
|
1746
|
+
C.I.P. forms elevated slab edge forms, including shoring, erection, bracing
|
1747
|
+
Reinforcing steel for elevated slabs and ceilings/roofa, grade 60, all assembly and accessories
|
1748
|
+
Structural concrete, 3000 PSI, complete delivered and pum,ped in place
|
1749
|
+
Structural concrete, placing, elevated slab, pumped, 6\"" to 10\"" thick, includes leveling (strike off) & consolidation
|
1750
|
+
Concrete finishing, specified Random Access Floors ACI Classes 1, 2, 3 & 4,
|
1751
|
+
Concrete surface treatment, curing, sprayed membrane compound
|
1752
|
+
",NECB_2011
|
1753
|
+
180,BG-ROOF,BTAP-GroundContactRoof-Mass-1,BTAP,1,GroundContactRoof,Mass,1,Zone 8,4.76,"Cast in Place Concrete Slab Roof , 7.5"" thick, 200 PSI with Exterior Insulation","40,40,40,109,110,111,112,113,144,143,114","XPS, 25 PSI, 2"" RSI 1.76
|
1754
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
1755
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
1756
|
+
Roof Insulation fastening, 4"" screws
|
1757
|
+
C.I.P. forms elevated slab floor hung from steel beams, including shoring, erection, bracing
|
1758
|
+
C.I.P. forms elevated slab edge forms, including shoring, erection, bracing
|
1759
|
+
Reinforcing steel for elevated slabs and ceilings/roofa, grade 60, all assembly and accessories
|
1760
|
+
Structural concrete, 3000 PSI, complete delivered and pum,ped in place
|
1761
|
+
Structural concrete, placing, elevated slab, pumped, 6\"" to 10\"" thick, includes leveling (strike off) & consolidation
|
1762
|
+
Concrete finishing, specified Random Access Floors ACI Classes 1, 2, 3 & 4,
|
1763
|
+
Concrete surface treatment, curing, sprayed membrane compound
|
1764
|
+
",NECB_2011
|
1765
|
+
181,BG-ROOF,BTAP-GroundContactRoof-Mass-2,BTAP,2,GroundContactRoof,Mass,2,Zone 4,1.76,"Cast in Place Concrete Slab Roof , 7.5"" thick, 200 PSI with Interior Insulation","110,111,112,113,144,143,114,40,109,115","C.I.P. forms elevated slab floor hung from steel beams, including shoring, erection, bracing
|
1766
|
+
C.I.P. forms elevated slab edge forms, including shoring, erection, bracing
|
1767
|
+
Reinforcing steel for elevated slabs and ceilings/roofa, grade 60, all assembly and accessories
|
1768
|
+
Structural concrete, 3000 PSI, complete delivered and pum,ped in place
|
1769
|
+
Structural concrete, placing, elevated slab, pumped, 6\"" to 10\"" thick, includes leveling (strike off) & consolidation
|
1770
|
+
Concrete finishing, specified Random Access Floors ACI Classes 1, 2, 3 & 4,
|
1771
|
+
Concrete surface treatment, curing, sprayed membrane compound
|
1772
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
1773
|
+
Roof Insulation fastening, 4"" screws
|
1774
|
+
Sprayed fireproofing, vermiculite cement, 0.25""
|
1775
|
+
",NECB_2011
|
1776
|
+
182,BG-ROOF,BTAP-GroundContactRoof-Mass-2,BTAP,2,GroundContactRoof,Mass,2,Zone 5,2.64,"Cast in Place Concrete Slab Roof , 7.5"" thick, 200 PSI with Interior Insulation","110,111,112,113,144,143,114,80,109,115","C.I.P. forms elevated slab floor hung from steel beams, including shoring, erection, bracing
|
1777
|
+
C.I.P. forms elevated slab edge forms, including shoring, erection, bracing
|
1778
|
+
Reinforcing steel for elevated slabs and ceilings/roofa, grade 60, all assembly and accessories
|
1779
|
+
Structural concrete, 3000 PSI, complete delivered and pum,ped in place
|
1780
|
+
Structural concrete, placing, elevated slab, pumped, 6\"" to 10\"" thick, includes leveling (strike off) & consolidation
|
1781
|
+
Concrete finishing, specified Random Access Floors ACI Classes 1, 2, 3 & 4,
|
1782
|
+
Concrete surface treatment, curing, sprayed membrane compound
|
1783
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
1784
|
+
Roof Insulation fastening, 4"" screws
|
1785
|
+
Sprayed fireproofing, vermiculite cement, 0.25""
|
1786
|
+
",NECB_2011
|
1787
|
+
183,BG-ROOF,BTAP-GroundContactRoof-Mass-2,BTAP,2,GroundContactRoof,Mass,2,Zone 6,3.52,"Cast in Place Concrete Slab Roof , 7.5"" thick, 200 PSI with Interior Insulation","110,111,112,113,144,143,114,42,109,115","C.I.P. forms elevated slab floor hung from steel beams, including shoring, erection, bracing
|
1788
|
+
C.I.P. forms elevated slab edge forms, including shoring, erection, bracing
|
1789
|
+
Reinforcing steel for elevated slabs and ceilings/roofa, grade 60, all assembly and accessories
|
1790
|
+
Structural concrete, 3000 PSI, complete delivered and pum,ped in place
|
1791
|
+
Structural concrete, placing, elevated slab, pumped, 6\"" to 10\"" thick, includes leveling (strike off) & consolidation
|
1792
|
+
Concrete finishing, specified Random Access Floors ACI Classes 1, 2, 3 & 4,
|
1793
|
+
Concrete surface treatment, curing, sprayed membrane compound
|
1794
|
+
XPS, 25 PSI, 2 sheets of 2"" RSI 1.76 each total 4"" RSI 3.52
|
1795
|
+
Roof Insulation fastening, 4"" screws
|
1796
|
+
Sprayed fireproofing, vermiculite cement, 0.25""
|
1797
|
+
",NECB_2011
|
1798
|
+
184,BG-ROOF,BTAP-GroundContactRoof-Mass-2,BTAP,2,GroundContactRoof,Mass,2,Zone 7A,3.52,"Cast in Place Concrete Slab Roof , 7.5"" thick, 200 PSI with Interior Insulation","110,111,112,113,144,143,114,42,109,115","C.I.P. forms elevated slab floor hung from steel beams, including shoring, erection, bracing
|
1799
|
+
C.I.P. forms elevated slab edge forms, including shoring, erection, bracing
|
1800
|
+
Reinforcing steel for elevated slabs and ceilings/roofa, grade 60, all assembly and accessories
|
1801
|
+
Structural concrete, 3000 PSI, complete delivered and pum,ped in place
|
1802
|
+
Structural concrete, placing, elevated slab, pumped, 6\"" to 10\"" thick, includes leveling (strike off) & consolidation
|
1803
|
+
Concrete finishing, specified Random Access Floors ACI Classes 1, 2, 3 & 4,
|
1804
|
+
Concrete surface treatment, curing, sprayed membrane compound
|
1805
|
+
XPS, 25 PSI, 2 sheets of 2"" RSI 1.76 each total 4"" RSI 3.52
|
1806
|
+
Roof Insulation fastening, 4"" screws
|
1807
|
+
Sprayed fireproofing, vermiculite cement, 0.25""
|
1808
|
+
",NECB_2011
|
1809
|
+
185,BG-ROOF,BTAP-GroundContactRoof-Mass-2,BTAP,2,GroundContactRoof,Mass,2,Zone 7B,3.52,"Cast in Place Concrete Slab Roof , 7.5"" thick, 200 PSI with Interior Insulation","110,111,112,113,144,143,114,42,109,115","C.I.P. forms elevated slab floor hung from steel beams, including shoring, erection, bracing
|
1810
|
+
C.I.P. forms elevated slab edge forms, including shoring, erection, bracing
|
1811
|
+
Reinforcing steel for elevated slabs and ceilings/roofa, grade 60, all assembly and accessories
|
1812
|
+
Structural concrete, 3000 PSI, complete delivered and pum,ped in place
|
1813
|
+
Structural concrete, placing, elevated slab, pumped, 6\"" to 10\"" thick, includes leveling (strike off) & consolidation
|
1814
|
+
Concrete finishing, specified Random Access Floors ACI Classes 1, 2, 3 & 4,
|
1815
|
+
Concrete surface treatment, curing, sprayed membrane compound
|
1816
|
+
XPS, 25 PSI, 2 sheets of 2"" RSI 1.76 each total 4"" RSI 3.52
|
1817
|
+
Roof Insulation fastening, 4"" screws
|
1818
|
+
Sprayed fireproofing, vermiculite cement, 0.25""
|
1819
|
+
",NECB_2011
|
1820
|
+
186,BG-ROOF,BTAP-GroundContactRoof-Mass-2,BTAP,2,GroundContactRoof,Mass,2,Zone 8,4.76,"Cast in Place Concrete Slab Roof , 7.5"" thick, 200 PSI with Interior Insulation","110,111,112,113,144,143,114,85,109,115","C.I.P. forms elevated slab floor hung from steel beams, including shoring, erection, bracing
|
1821
|
+
C.I.P. forms elevated slab edge forms, including shoring, erection, bracing
|
1822
|
+
Reinforcing steel for elevated slabs and ceilings/roofa, grade 60, all assembly and accessories
|
1823
|
+
Structural concrete, 3000 PSI, complete delivered and pum,ped in place
|
1824
|
+
Structural concrete, placing, elevated slab, pumped, 6\"" to 10\"" thick, includes leveling (strike off) & consolidation
|
1825
|
+
Concrete finishing, specified Random Access Floors ACI Classes 1, 2, 3 & 4,
|
1826
|
+
Concrete surface treatment, curing, sprayed membrane compound
|
1827
|
+
XPS, 25 PSI, 3"" RSI 2.64 modified to 1x 3"" sheet and 1x 2.25"" sheet RSI 4.63
|
1828
|
+
Roof Insulation fastening, 4"" screws
|
1829
|
+
Sprayed fireproofing, vermiculite cement, 0.25""
|
1830
|
+
",NECB_2011
|
1831
|
+
187,BG-WALL,BTAP-GroundContactWall-Mass-1,BTAP,1,GroundContactWall,Mass,1,Zone 4,1.76,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted Exterior Insulation","24,25,26,27,28,40","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
1832
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
1833
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
1834
|
+
Control joint, PVC
|
1835
|
+
Grout, 8"" thick including pumping
|
1836
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
1837
|
+
",NECB_2011
|
1838
|
+
188,BG-WALL,BTAP-GroundContactWall-Mass-1,BTAP,1,GroundContactWall,Mass,1,Zone 5,2.64,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted Exterior Insulation","24,25,26,27,28,80","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
1839
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
1840
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
1841
|
+
Control joint, PVC
|
1842
|
+
Grout, 8"" thick including pumping
|
1843
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
1844
|
+
",NECB_2011
|
1845
|
+
189,BG-WALL,BTAP-GroundContactWall-Mass-1,BTAP,1,GroundContactWall,Mass,1,Zone 6,3.52,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted Exterior Insulation","24,25,26,27,28,82","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
1846
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
1847
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
1848
|
+
Control joint, PVC
|
1849
|
+
Grout, 8"" thick including pumping
|
1850
|
+
XPS, 25 PSI, 2"" RSI 1.76 modified to 2 sheets 4"" RSI 3.52
|
1851
|
+
",NECB_2011
|
1852
|
+
190,BG-WALL,BTAP-GroundContactWall-Mass-1,BTAP,1,GroundContactWall,Mass,1,Zone 7A,3.52,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted Exterior Insulation","24,25,26,27,28,84","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
1853
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
1854
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
1855
|
+
Control joint, PVC
|
1856
|
+
Grout, 8"" thick including pumping
|
1857
|
+
XPS, 25 PSI, 2"" RSI 1.76 modified to 2 sheets 4"" RSI 3.52
|
1858
|
+
",NECB_2011
|
1859
|
+
191,BG-WALL,BTAP-GroundContactWall-Mass-1,BTAP,1,GroundContactWall,Mass,1,Zone 7B,3.52,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted Exterior Insulation","24,25,26,27,28,84","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
1860
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
1861
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
1862
|
+
Control joint, PVC
|
1863
|
+
Grout, 8"" thick including pumping
|
1864
|
+
XPS, 25 PSI, 2"" RSI 1.76 modified to 2 sheets 4"" RSI 3.52
|
1865
|
+
",NECB_2011
|
1866
|
+
192,BG-WALL,BTAP-GroundContactWall-Mass-1,BTAP,1,GroundContactWall,Mass,1,Zone 8,4.76,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Grouted Exterior Insulation","24,25,26,27,28,85","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
1867
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
1868
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
1869
|
+
Control joint, PVC
|
1870
|
+
Grout, 8"" thick including pumping
|
1871
|
+
XPS, 25 PSI, 3"" RSI 2.64 modified to 1x 3"" sheet and 1x 2.25"" sheet RSI 4.63
|
1872
|
+
",NECB_2011
|
1873
|
+
193,BG-WALL,BTAP-GroundContactWall-Mass-2,BTAP,2,GroundContactWall,Mass,2,Zone 4,1.76,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Interior Insulation","24,25,26,27,28,40","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
1874
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
1875
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
1876
|
+
Control joint, PVC
|
1877
|
+
Grout, 8"" thick including pumping
|
1878
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
1879
|
+
",NECB_2011
|
1880
|
+
194,BG-WALL,BTAP-GroundContactWall-Mass-2,BTAP,2,GroundContactWall,Mass,2,Zone 5,2.64,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Interior Insulation","24,25,26,27,28,80","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
1881
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
1882
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
1883
|
+
Control joint, PVC
|
1884
|
+
Grout, 8"" thick including pumping
|
1885
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
1886
|
+
",NECB_2011
|
1887
|
+
195,BG-WALL,BTAP-GroundContactWall-Mass-2,BTAP,2,GroundContactWall,Mass,2,Zone 6,3.52,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Interior Insulation","24,25,26,27,28,82","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
1888
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
1889
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
1890
|
+
Control joint, PVC
|
1891
|
+
Grout, 8"" thick including pumping
|
1892
|
+
XPS, 25 PSI, 2"" RSI 1.76 modified to 2 sheets 4"" RSI 3.52
|
1893
|
+
",NECB_2011
|
1894
|
+
196,BG-WALL,BTAP-GroundContactWall-Mass-2,BTAP,2,GroundContactWall,Mass,2,Zone 7A,3.52,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Interior Insulation","24,25,26,27,28,84","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
1895
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
1896
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
1897
|
+
Control joint, PVC
|
1898
|
+
Grout, 8"" thick including pumping
|
1899
|
+
XPS, 25 PSI, 2"" RSI 1.76 modified to 2 sheets 4"" RSI 3.52
|
1900
|
+
",NECB_2011
|
1901
|
+
197,BG-WALL,BTAP-GroundContactWall-Mass-2,BTAP,2,GroundContactWall,Mass,2,Zone 7B,3.52,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Interior Insulation","24,25,26,27,28,84","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
1902
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
1903
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
1904
|
+
Control joint, PVC
|
1905
|
+
Grout, 8"" thick including pumping
|
1906
|
+
XPS, 25 PSI, 2"" RSI 1.76 modified to 2 sheets 4"" RSI 3.52
|
1907
|
+
",NECB_2011
|
1908
|
+
198,BG-WALL,BTAP-GroundContactWall-Mass-2,BTAP,2,GroundContactWall,Mass,2,Zone 8,4.76,"Concrete Block Wall, Regular Weight 6 x 8 x 16 Hollow Core, 2000 PSI, Reinforced and Interior Insulation","24,25,26,27,28,85","Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout
|
1909
|
+
masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally
|
1910
|
+
masonry #5 and #6 reinforcing bars placed vertically
|
1911
|
+
Control joint, PVC
|
1912
|
+
Grout, 8"" thick including pumping
|
1913
|
+
XPS, 25 PSI, 3"" RSI 2.64 modified to 1x 3"" sheet and 1x 2.25"" sheet RSI 4.63
|
1914
|
+
",NECB_2011
|
1915
|
+
199,DOORS,BTAP-ExteriorDoor-Metal-1,BTAP,2,ExteriorDoor,Metal,1,Zone 4,2.4,Metal Door,146,"Metal Door 20 gauge, includes hardware
|
1916
|
+
",NECB_2011
|
1917
|
+
200,DOORS,BTAP-ExteriorDoor-Metal-1,BTAP,2,ExteriorDoor,Metal,1,Zone 5,2.2,Metal Door,146,"Metal Door 20 gauge, includes hardware
|
1918
|
+
",NECB_2011
|
1919
|
+
201,DOORS,BTAP-ExteriorDoor-Metal-1,BTAP,2,ExteriorDoor,Metal,1,Zone 6,2.2,Metal Door,146,"Metal Door 20 gauge, includes hardware
|
1920
|
+
",NECB_2011
|
1921
|
+
202,DOORS,BTAP-ExteriorDoor-Metal-1,BTAP,2,ExteriorDoor,Metal,1,Zone 7A,2.2,Metal Door,146,"Metal Door 20 gauge, includes hardware
|
1922
|
+
",NECB_2011
|
1923
|
+
203,DOORS,BTAP-ExteriorDoor-Metal-1,BTAP,2,ExteriorDoor,Metal,1,Zone 7B,2.2,Metal Door,146,"Metal Door 20 gauge, includes hardware
|
1924
|
+
",NECB_2011
|
1925
|
+
204,DOORS,BTAP-ExteriorDoor-Metal-1,BTAP,2,ExteriorDoor,Metal,1,Zone 8,1.6,Fibreglas Door,146,"Metal Door 20 gauge, includes hardware
|
1926
|
+
",NECB_2011
|
1927
|
+
205,DOORS,BTAP-ExteriorOverheadDoor-Metal-1,BTAP,2,ExteriorOverheadDoor,Metal,1,Zone 4,2.4,Overhead Door,149,"Steel Overhead Rolling Door, 10'-0 x 10'-0' includes hardware
|
1928
|
+
",NECB_2011
|
1929
|
+
206,DOORS,BTAP-ExteriorOverheadDoor-Metal-1,BTAP,2,ExteriorOverheadDoor,Metal,1,Zone 5,2.2,Overhead Door,149,"Steel Overhead Rolling Door, 10'-0 x 10'-0' includes hardware
|
1930
|
+
",NECB_2011
|
1931
|
+
207,DOORS,BTAP-ExteriorOverheadDoor-Metal-1,BTAP,2,ExteriorOverheadDoor,Metal,1,Zone 6,2.2,Overhead Door,149,"Steel Overhead Rolling Door, 10'-0 x 10'-0' includes hardware
|
1932
|
+
",NECB_2011
|
1933
|
+
208,DOORS,BTAP-ExteriorOverheadDoor-Metal-1,BTAP,2,ExteriorOverheadDoor,Metal,1,Zone 7A,2.2,Overhead Door,149,"Steel Overhead Rolling Door, 10'-0 x 10'-0' includes hardware
|
1934
|
+
",NECB_2011
|
1935
|
+
209,DOORS,BTAP-ExteriorOverheadDoor-Metal-1,BTAP,2,ExteriorOverheadDoor,Metal,1,Zone 7B,2.2,Overhead Door,149,"Steel Overhead Rolling Door, 10'-0 x 10'-0' includes hardware
|
1936
|
+
",NECB_2011
|
1937
|
+
210,DOORS,BTAP-ExteriorOverheadDoor-Metal-1,BTAP,2,ExteriorOverheadDoor,Metal,1,Zone 8,1.6,Overhead Door,149,"Steel Overhead Rolling Door, 10'-0 x 10'-0' includes hardware
|
1938
|
+
",NECB_2011
|
1939
|
+
211,ROOF,BTAP-ExteriorRoof-IEAD-1,BTAP,1,ExteriorRoof,IEAD,1,Zone 4,5.18,Built-up Deck Roof on a Nailable Deck,"87,97,80,80,90","asphalt flood coat, gravel base coated glass-fibre sheet and 3 plies glass fibre felt (type IV) mopped on nailable deck
|
1940
|
+
Plywood underlayment 0.75' thick
|
1941
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
1942
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
1943
|
+
Spruce Wood decking, 2 "" thick
|
1944
|
+
",NECB_2017
|
1945
|
+
212,ROOF,BTAP-ExteriorRoof-IEAD-1,BTAP,1,ExteriorRoof,IEAD,1,Zone 5,6.41,Built-up Deck Roof on a Nailable Deck,"87,97,134,91,90","asphalt flood coat, gravel base coated glass-fibre sheet and 3 plies glass fibre felt (type IV) mopped on nailable deck
|
1946
|
+
Plywood underlayment 0.75' thick
|
1947
|
+
XPS, 3"" 2.64
|
1948
|
+
roof deck extruded polystyrene, 4"" (RSI 3.52), 25 PSI
|
1949
|
+
Spruce Wood decking, 2 "" thick
|
1950
|
+
",NECB_2017
|
1951
|
+
213,ROOF,BTAP-ExteriorRoof-IEAD-1,BTAP,1,ExteriorRoof,IEAD,1,Zone 6,6.41,Built-up Deck Roof on a Nailable Deck,"87,97,80,80,150,158,90","asphalt flood coat, gravel base coated glass-fibre sheet and 3 plies glass fibre felt (type IV) mopped on nailable deck
|
1952
|
+
Plywood underlayment 0.75' thick
|
1953
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
1954
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
1955
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
1956
|
+
XPS, 3/4"" RSI 0.501
|
1957
|
+
Spruce Wood decking, 2 "" thick
|
1958
|
+
",NECB_2017
|
1959
|
+
214,ROOF,BTAP-ExteriorRoof-IEAD-1,BTAP,1,ExteriorRoof,IEAD,1,Zone 7A,7.25,Built-up Deck Roof on a Nailable Deck,"87,97,80,80,80,90","asphalt flood coat, gravel base coated glass-fibre sheet and 3 plies glass fibre felt (type IV) mopped on nailable deck
|
1960
|
+
Plywood underlayment 0.75' thick
|
1961
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
1962
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
1963
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
1964
|
+
Spruce Wood decking, 2 "" thick
|
1965
|
+
",NECB_2017
|
1966
|
+
215,ROOF,BTAP-ExteriorRoof-IEAD-1,BTAP,1,ExteriorRoof,IEAD,1,Zone 7B,7.25,Built-up Deck Roof on a Nailable Deck,"87,97,80,80,80,90","asphalt flood coat, gravel base coated glass-fibre sheet and 3 plies glass fibre felt (type IV) mopped on nailable deck
|
1967
|
+
Plywood underlayment 0.75' thick
|
1968
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
1969
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
1970
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
1971
|
+
Spruce Wood decking, 2 "" thick
|
1972
|
+
",NECB_2017
|
1973
|
+
216,ROOF,BTAP-ExteriorRoof-IEAD-1,BTAP,1,ExteriorRoof,IEAD,1,Zone 8,8.26,Built-up Deck Roof on a Nailable Deck,"87,97,80,80,80,158,90","asphalt flood coat, gravel base coated glass-fibre sheet and 3 plies glass fibre felt (type IV) mopped on nailable deck
|
1974
|
+
Plywood underlayment 0.75' thick
|
1975
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
1976
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
1977
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
1978
|
+
XPS, 3/4"" RSI 0.501
|
1979
|
+
Spruce Wood decking, 2 "" thick
|
1980
|
+
",NECB_2017
|
1981
|
+
217,ROOF,BTAP-ExteriorRoof-IEAD-2,BTAP,2,ExteriorRoof,IEAD,2,Zone 4,5.18,Built-up Deck Roof on a Nailable Deck,"87,97,80,80,93","asphalt flood coat, gravel base coated glass-fibre sheet and 3 plies glass fibre felt (type IV) mopped on nailable deck
|
1982
|
+
Plywood underlayment 0.75' thick
|
1983
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
1984
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
1985
|
+
Steel decking, open type galvanized, 1.5"" rib depth, 18 gauge
|
1986
|
+
",NECB_2017
|
1987
|
+
218,ROOF,BTAP-ExteriorRoof-IEAD-2,BTAP,2,ExteriorRoof,IEAD,2,Zone 5,6.41,Built-up Deck Roof on a Nailable Deck,"87,97,80,80,150,158,93","asphalt flood coat, gravel base coated glass-fibre sheet and 3 plies glass fibre felt (type IV) mopped on nailable deck
|
1988
|
+
Plywood underlayment 0.75' thick
|
1989
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
1990
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
1991
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
1992
|
+
XPS, 3/4"" RSI 0.501
|
1993
|
+
Steel decking, open type galvanized, 1.5"" rib depth, 18 gauge
|
1994
|
+
",NECB_2017
|
1995
|
+
219,ROOF,BTAP-ExteriorRoof-IEAD-2,BTAP,2,ExteriorRoof,IEAD,2,Zone 6,6.41,Built-up Deck Roof on a Nailable Deck,"87,97,80,80,150,158,93","asphalt flood coat, gravel base coated glass-fibre sheet and 3 plies glass fibre felt (type IV) mopped on nailable deck
|
1996
|
+
Plywood underlayment 0.75' thick
|
1997
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
1998
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
1999
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
2000
|
+
XPS, 3/4"" RSI 0.501
|
2001
|
+
Steel decking, open type galvanized, 1.5"" rib depth, 18 gauge
|
2002
|
+
",NECB_2017
|
2003
|
+
220,ROOF,BTAP-ExteriorRoof-IEAD-2,BTAP,2,ExteriorRoof,IEAD,2,Zone 7A,7.25,Built-up Deck Roof on a Nailable Deck,"87,97,80,80,80,93","asphalt flood coat, gravel base coated glass-fibre sheet and 3 plies glass fibre felt (type IV) mopped on nailable deck
|
2004
|
+
Plywood underlayment 0.75' thick
|
2005
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2006
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2007
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2008
|
+
Steel decking, open type galvanized, 1.5"" rib depth, 18 gauge
|
2009
|
+
",NECB_2017
|
2010
|
+
221,ROOF,BTAP-ExteriorRoof-IEAD-2,BTAP,2,ExteriorRoof,IEAD,2,Zone 7B,7.25,Built-up Deck Roof on a Nailable Deck,"87,97,80,80,80,93","asphalt flood coat, gravel base coated glass-fibre sheet and 3 plies glass fibre felt (type IV) mopped on nailable deck
|
2011
|
+
Plywood underlayment 0.75' thick
|
2012
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2013
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2014
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2015
|
+
Steel decking, open type galvanized, 1.5"" rib depth, 18 gauge
|
2016
|
+
",NECB_2017
|
2017
|
+
222,ROOF,BTAP-ExteriorRoof-IEAD-2,BTAP,2,ExteriorRoof,IEAD,2,Zone 8,8.26,Built-up Deck Roof on a Nailable Deck,"87,97,80,80,80,158,93","asphalt flood coat, gravel base coated glass-fibre sheet and 3 plies glass fibre felt (type IV) mopped on nailable deck
|
2018
|
+
Plywood underlayment 0.75' thick
|
2019
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2020
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2021
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2022
|
+
XPS, 3/4"" RSI 0.501
|
2023
|
+
Steel decking, open type galvanized, 1.5"" rib depth, 18 gauge
|
2024
|
+
",NECB_2017
|
2025
|
+
223,ROOF,BTAP-ExteriorRoof-IEAD-3,BTAP,3,ExteriorRoof,IEAD,3,Zone 4,5.18,Deck Roof with a Membrane on a Nailable Deck,"94,97,80,80,90","60 ml Single ply EPDM membrane fully adhered to underlayment, 0.4 lb/ft2 no ballast or aggregate topping
|
2026
|
+
Plywood underlayment 0.75' thick
|
2027
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2028
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2029
|
+
Spruce Wood decking, 2 "" thick
|
2030
|
+
",NECB_2017
|
2031
|
+
224,ROOF,BTAP-ExteriorRoof-IEAD-3,BTAP,3,ExteriorRoof,IEAD,3,Zone 5,6.41,Deck Roof with a Membrane on a Nailable Deck,"94,97,80,80,150,158,90","60 ml Single ply EPDM membrane fully adhered to underlayment, 0.4 lb/ft2 no ballast or aggregate topping
|
2032
|
+
Plywood underlayment 0.75' thick
|
2033
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2034
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2035
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
2036
|
+
XPS, 3/4"" RSI 0.501
|
2037
|
+
Spruce Wood decking, 2 "" thick
|
2038
|
+
",NECB_2017
|
2039
|
+
225,ROOF,BTAP-ExteriorRoof-IEAD-3,BTAP,3,ExteriorRoof,IEAD,3,Zone 6,6.41,Deck Roof with a Membrane on a Nailable Deck,"94,97,134,91,90","60 ml Single ply EPDM membrane fully adhered to underlayment, 0.4 lb/ft2 no ballast or aggregate topping
|
2040
|
+
Plywood underlayment 0.75' thick
|
2041
|
+
XPS, 3"" 2.64
|
2042
|
+
roof deck extruded polystyrene, 4"" (RSI 3.52), 25 PSI
|
2043
|
+
Spruce Wood decking, 2 "" thick
|
2044
|
+
",NECB_2017
|
2045
|
+
226,ROOF,BTAP-ExteriorRoof-IEAD-3,BTAP,3,ExteriorRoof,IEAD,3,Zone 7A,7.25,Deck Roof with a Membrane on a Nailable Deck,"94,97,80,80,80,90","60 ml Single ply EPDM membrane fully adhered to underlayment, 0.4 lb/ft2 no ballast or aggregate topping
|
2046
|
+
Plywood underlayment 0.75' thick
|
2047
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2048
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2049
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2050
|
+
Spruce Wood decking, 2 "" thick
|
2051
|
+
",NECB_2017
|
2052
|
+
227,ROOF,BTAP-ExteriorRoof-IEAD-3,BTAP,3,ExteriorRoof,IEAD,3,Zone 7B,7.25,Deck Roof with a Membrane on a Nailable Deck,"94,97,80,80,80,90","60 ml Single ply EPDM membrane fully adhered to underlayment, 0.4 lb/ft2 no ballast or aggregate topping
|
2053
|
+
Plywood underlayment 0.75' thick
|
2054
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2055
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2056
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2057
|
+
Spruce Wood decking, 2 "" thick
|
2058
|
+
",NECB_2017
|
2059
|
+
228,ROOF,BTAP-ExteriorRoof-IEAD-3,BTAP,3,ExteriorRoof,IEAD,3,Zone 8,8.26,Deck Roof with a Membrane on a Nailable Deck,"94,97,80,80,80,158,90","60 ml Single ply EPDM membrane fully adhered to underlayment, 0.4 lb/ft2 no ballast or aggregate topping
|
2060
|
+
Plywood underlayment 0.75' thick
|
2061
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2062
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2063
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2064
|
+
XPS, 3/4"" RSI 0.501
|
2065
|
+
Spruce Wood decking, 2 "" thick
|
2066
|
+
",NECB_2017
|
2067
|
+
235,ROOF,BTAP-ExteriorRoof-IEAD-5,BTAP,6,ExteriorRoof,IEAD,5,Zone 4,5.18,"Asphalt Shingle Roofing, ","98,96,97,150,91,97","Premium shingles, Class A, 300-385 lbs/ft2, pneumatic nailer
|
2068
|
+
Asphalt felt, #15
|
2069
|
+
Plywood underlayment 0.75' thick
|
2070
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
2071
|
+
roof deck extruded polystyrene, 4"" (RSI 3.52), 25 PSI
|
2072
|
+
Plywood underlayment 0.75' thick
|
2073
|
+
",NECB_2017
|
2074
|
+
236,ROOF,BTAP-ExteriorRoof-IEAD-5,BTAP,6,ExteriorRoof,IEAD,5,Zone 5,6.41,"Asphalt Shingle Roofing, ","98,96,97,100,55,97","Premium shingles, Class A, 300-385 lbs/ft2, pneumatic nailer
|
2075
|
+
Asphalt felt, #15
|
2076
|
+
Plywood underlayment 0.75' thick
|
2077
|
+
Isoboard, 1.5 in thick RSI 1.48
|
2078
|
+
XPS, 25 PSI, 2"" RSI 1.76 modified to 2 x 2.5"" sheets: total 5"" RSI 4.4
|
2079
|
+
Plywood underlayment 0.75' thick
|
2080
|
+
",NECB_2017
|
2081
|
+
237,ROOF,BTAP-ExteriorRoof-IEAD-5,BTAP,6,ExteriorRoof,IEAD,5,Zone 6,6.41,"Asphalt Shingle Roofing, ","98,96,97,100,55,97","Premium shingles, Class A, 300-385 lbs/ft2, pneumatic nailer
|
2082
|
+
Asphalt felt, #15
|
2083
|
+
Plywood underlayment 0.75' thick
|
2084
|
+
Isoboard, 1.5 in thick RSI 1.48
|
2085
|
+
XPS, 25 PSI, 2"" RSI 1.76 modified to 2 x 2.5"" sheets: total 5"" RSI 4.4
|
2086
|
+
Plywood underlayment 0.75' thick
|
2087
|
+
",NECB_2017
|
2088
|
+
238,ROOF,BTAP-ExteriorRoof-IEAD-5,BTAP,6,ExteriorRoof,IEAD,5,Zone 7A,7.25,"Asphalt Shingle Roofing, ","98,96,97,54,106,97","Premium shingles, Class A, 300-385 lbs/ft2, pneumatic nailer
|
2089
|
+
Asphalt felt, #15
|
2090
|
+
Plywood underlayment 0.75' thick
|
2091
|
+
0.5"" Isoboard, 4 x 8 sheet, foil faced (RSI 0.48)
|
2092
|
+
roof deck extruded polystyrene, 4"" (RSI 3.52), 25 PSI modifed to 2x4"" sheets RSI 7.04
|
2093
|
+
Plywood underlayment 0.75' thick
|
2094
|
+
",NECB_2017
|
2095
|
+
239,ROOF,BTAP-ExteriorRoof-IEAD-5,BTAP,6,ExteriorRoof,IEAD,5,Zone 7B,7.25,"Asphalt Shingle Roofing, ","98,96,97,54,106,97","Premium shingles, Class A, 300-385 lbs/ft2, pneumatic nailer
|
2096
|
+
Asphalt felt, #15
|
2097
|
+
Plywood underlayment 0.75' thick
|
2098
|
+
0.5"" Isoboard, 4 x 8 sheet, foil faced (RSI 0.48)
|
2099
|
+
roof deck extruded polystyrene, 4"" (RSI 3.52), 25 PSI modifed to 2x4"" sheets RSI 7.04
|
2100
|
+
Plywood underlayment 0.75' thick
|
2101
|
+
",NECB_2017
|
2102
|
+
240,ROOF,BTAP-ExteriorRoof-IEAD-5,BTAP,6,ExteriorRoof,IEAD,5,Zone 8,8.26,"Asphalt Shingle Roofing, ","98,96,97,106,150,97","Premium shingles, Class A, 300-385 lbs/ft2, pneumatic nailer
|
2103
|
+
Asphalt felt, #15
|
2104
|
+
Plywood underlayment 0.75' thick
|
2105
|
+
roof deck extruded polystyrene, 4"" (RSI 3.52), 25 PSI modifed to 2x4"" sheets RSI 7.04
|
2106
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
2107
|
+
Plywood underlayment 0.75' thick
|
2108
|
+
",NECB_2017
|
2109
|
+
241,ROOF,BTAP-ExteriorRoof-IEAD-6,BTAP,8,ExteriorRoof,IEAD,6,Zone 4,5.18,"Asphalt Shingle Roofing, Attic Insulation","98,96,97,154,3,1","Premium shingles, Class A, 300-385 lbs/ft2, pneumatic nailer
|
2110
|
+
Asphalt felt, #15
|
2111
|
+
Plywood underlayment 0.75' thick
|
2112
|
+
10 inch fibreglass insulation RSI 5.86
|
2113
|
+
polyethylene 4 ml vapour barrier
|
2114
|
+
gypsum wallboard 0.5 in thick
|
2115
|
+
",NECB_2017
|
2116
|
+
242,ROOF,BTAP-ExteriorRoof-IEAD-6,BTAP,8,ExteriorRoof,IEAD,6,Zone 5,6.41,"Asphalt Shingle Roofing, Attic Insulation","98,96,97,101,3,1","Premium shingles, Class A, 300-385 lbs/ft2, pneumatic nailer
|
2117
|
+
Asphalt felt, #15
|
2118
|
+
Plywood underlayment 0.75' thick
|
2119
|
+
12"" thick fibreglass, kraft coated ceiling insulation, 15"" wide blanket (RSI 6.69)
|
2120
|
+
polyethylene 4 ml vapour barrier
|
2121
|
+
gypsum wallboard 0.5 in thick
|
2122
|
+
",NECB_2017
|
2123
|
+
243,ROOF,BTAP-ExteriorRoof-IEAD-6,BTAP,8,ExteriorRoof,IEAD,6,Zone 6,6.41,"Asphalt Shingle Roofing, Attic Insulation","98,96,97,101,3,1","Premium shingles, Class A, 300-385 lbs/ft2, pneumatic nailer
|
2124
|
+
Asphalt felt, #15
|
2125
|
+
Plywood underlayment 0.75' thick
|
2126
|
+
12"" thick fibreglass, kraft coated ceiling insulation, 15"" wide blanket (RSI 6.69)
|
2127
|
+
polyethylene 4 ml vapour barrier
|
2128
|
+
gypsum wallboard 0.5 in thick
|
2129
|
+
",NECB_2017
|
2130
|
+
244,ROOF,BTAP-ExteriorRoof-IEAD-6,BTAP,8,ExteriorRoof,IEAD,6,Zone 7A,7.25,"Asphalt Shingle Roofing, Attic Insulation","98,96,97,104,3,1","Premium shingles, Class A, 300-385 lbs/ft2, pneumatic nailer
|
2131
|
+
Asphalt felt, #15
|
2132
|
+
Plywood underlayment 0.75' thick
|
2133
|
+
18"" thick fibreglass blown ceiling (RSI 7.9)
|
2134
|
+
polyethylene 4 ml vapour barrier
|
2135
|
+
gypsum wallboard 0.5 in thick
|
2136
|
+
",NECB_2017
|
2137
|
+
245,ROOF,BTAP-ExteriorRoof-IEAD-6,BTAP,8,ExteriorRoof,IEAD,6,Zone 7B,7.25,"Asphalt Shingle Roofing, Attic Insulation","98,96,97,104,3,1","Premium shingles, Class A, 300-385 lbs/ft2, pneumatic nailer
|
2138
|
+
Asphalt felt, #15
|
2139
|
+
Plywood underlayment 0.75' thick
|
2140
|
+
18"" thick fibreglass blown ceiling (RSI 7.9)
|
2141
|
+
polyethylene 4 ml vapour barrier
|
2142
|
+
gypsum wallboard 0.5 in thick
|
2143
|
+
",NECB_2017
|
2144
|
+
246,ROOF,BTAP-ExteriorRoof-IEAD-6,BTAP,8,ExteriorRoof,IEAD,6,Zone 8,8.26,"Asphalt Shingle Roofing, Attic Insulation","98,96,97,107,3,108","Premium shingles, Class A, 300-385 lbs/ft2, pneumatic nailer
|
2145
|
+
Asphalt felt, #15
|
2146
|
+
Plywood underlayment 0.75' thick
|
2147
|
+
20"" thick fibreglass blown ceiling (RSI 8.63)
|
2148
|
+
polyethylene 4 ml vapour barrier
|
2149
|
+
gypsum wallboard 0.5 in thick
|
2150
|
+
",NECB_2017
|
2151
|
+
247,ROOF,BTAP-ExteriorRoof-Metal-1,BTAP,5,ExteriorRoof,Metal,1,Zone 4,5.18,"Steel Roofing, painted galvanized ","95,96,97,57,80,97","Zinc Steel roofing, 28 gauge, .020"" thick, 115 lb/ft2
|
2152
|
+
Asphalt felt, #15
|
2153
|
+
Plywood underlayment 0.75' thick
|
2154
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
2155
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2156
|
+
Plywood underlayment 0.75' thick
|
2157
|
+
",NECB_2017
|
2158
|
+
248,ROOF,BTAP-ExteriorRoof-Metal-1,BTAP,5,ExteriorRoof,Metal,1,Zone 5,6.41,"Steel Roofing, painted galvanized ","95,96,97,80,80,150,158,97","Zinc Steel roofing, 28 gauge, .020"" thick, 115 lb/ft2
|
2159
|
+
Asphalt felt, #15
|
2160
|
+
Plywood underlayment 0.75' thick
|
2161
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2162
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2163
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
2164
|
+
XPS, 3/4"" RSI 0.501
|
2165
|
+
Plywood underlayment 0.75' thick
|
2166
|
+
",NECB_2017
|
2167
|
+
249,ROOF,BTAP-ExteriorRoof-Metal-1,BTAP,5,ExteriorRoof,Metal,1,Zone 6,6.41,"Steel Roofing, painted galvanized ","95,96,97,80,80,150,158,97","Zinc Steel roofing, 28 gauge, .020"" thick, 115 lb/ft2
|
2168
|
+
Asphalt felt, #15
|
2169
|
+
Plywood underlayment 0.75' thick
|
2170
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2171
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2172
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
2173
|
+
XPS, 3/4"" RSI 0.501
|
2174
|
+
Plywood underlayment 0.75' thick
|
2175
|
+
",NECB_2017
|
2176
|
+
250,ROOF,BTAP-ExteriorRoof-Metal-1,BTAP,5,ExteriorRoof,Metal,1,Zone 7A,7.25,"Steel Roofing, painted galvanized ","95,96,97,80,80,80,97","Zinc Steel roofing, 28 gauge, .020"" thick, 115 lb/ft2
|
2177
|
+
Asphalt felt, #15
|
2178
|
+
Plywood underlayment 0.75' thick
|
2179
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2180
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2181
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2182
|
+
Plywood underlayment 0.75' thick
|
2183
|
+
",NECB_2017
|
2184
|
+
251,ROOF,BTAP-ExteriorRoof-Metal-1,BTAP,5,ExteriorRoof,Metal,1,Zone 7B,7.25,"Steel Roofing, painted galvanized ","95,96,97,80,80,80,97","Zinc Steel roofing, 28 gauge, .020"" thick, 115 lb/ft2
|
2185
|
+
Asphalt felt, #15
|
2186
|
+
Plywood underlayment 0.75' thick
|
2187
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2188
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2189
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2190
|
+
Plywood underlayment 0.75' thick
|
2191
|
+
",NECB_2017
|
2192
|
+
252,ROOF,BTAP-ExteriorRoof-Metal-1,BTAP,5,ExteriorRoof,Metal,1,Zone 8,8.26,"Steel Roofing, painted galvanized ","95,96,97,80,80,80,158,97","Zinc Steel roofing, 28 gauge, .020"" thick, 115 lb/ft2
|
2193
|
+
Asphalt felt, #15
|
2194
|
+
Plywood underlayment 0.75' thick
|
2195
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2196
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2197
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2198
|
+
XPS, 3/4"" RSI 0.501
|
2199
|
+
Plywood underlayment 0.75' thick
|
2200
|
+
",NECB_2017
|
2201
|
+
253,ROOF,BTAP-ExteriorRoof-Metal-2,BTAP,7,ExteriorRoof,Metal,2,Zone 4,5.18,"Steel Roofing, painted galvanized Attic Insulation","95,96,97,57,80,3,1","Zinc Steel roofing, 28 gauge, .020"" thick, 115 lb/ft2
|
2202
|
+
Asphalt felt, #15
|
2203
|
+
Plywood underlayment 0.75' thick
|
2204
|
+
XPS, 25 PSI, 2"" RSI 1.76
|
2205
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2206
|
+
polyethylene 4 ml vapour barrier
|
2207
|
+
gypsum wallboard 0.5 in thick
|
2208
|
+
",NECB_2017
|
2209
|
+
254,ROOF,BTAP-ExteriorRoof-Metal-2,BTAP,7,ExteriorRoof,Metal,2,Zone 5,6.41,"Steel Roofing, painted galvanized Attic Insulation","95,96,97,80,80,150,158,3,1","Zinc Steel roofing, 28 gauge, .020"" thick, 115 lb/ft2
|
2210
|
+
Asphalt felt, #15
|
2211
|
+
Plywood underlayment 0.75' thick
|
2212
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2213
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2214
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
2215
|
+
XPS, 3/4"" RSI 0.501
|
2216
|
+
polyethylene 4 ml vapour barrier
|
2217
|
+
gypsum wallboard 0.5 in thick
|
2218
|
+
",NECB_2017
|
2219
|
+
255,ROOF,BTAP-ExteriorRoof-Metal-2,BTAP,7,ExteriorRoof,Metal,2,Zone 6,6.41,"Steel Roofing, painted galvanized Attic Insulation","95,96,97,80,80,150,158,3,1","Zinc Steel roofing, 28 gauge, .020"" thick, 115 lb/ft2
|
2220
|
+
Asphalt felt, #15
|
2221
|
+
Plywood underlayment 0.75' thick
|
2222
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2223
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2224
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
2225
|
+
XPS, 3/4"" RSI 0.501
|
2226
|
+
polyethylene 4 ml vapour barrier
|
2227
|
+
gypsum wallboard 0.5 in thick
|
2228
|
+
",NECB_2017
|
2229
|
+
256,ROOF,BTAP-ExteriorRoof-Metal-2,BTAP,7,ExteriorRoof,Metal,2,Zone 7A,7.25,"Steel Roofing, painted galvanized Attic Insulation","95,96,97,80,80,80,3,1","Zinc Steel roofing, 28 gauge, .020"" thick, 115 lb/ft2
|
2230
|
+
Asphalt felt, #15
|
2231
|
+
Plywood underlayment 0.75' thick
|
2232
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2233
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2234
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2235
|
+
polyethylene 4 ml vapour barrier
|
2236
|
+
gypsum wallboard 0.5 in thick
|
2237
|
+
",NECB_2017
|
2238
|
+
257,ROOF,BTAP-ExteriorRoof-Metal-2,BTAP,7,ExteriorRoof,Metal,2,Zone 7B,7.25,"Steel Roofing, painted galvanized Attic Insulation","95,96,97,80,80,80,3,1","Zinc Steel roofing, 28 gauge, .020"" thick, 115 lb/ft2
|
2239
|
+
Asphalt felt, #15
|
2240
|
+
Plywood underlayment 0.75' thick
|
2241
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2242
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2243
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2244
|
+
polyethylene 4 ml vapour barrier
|
2245
|
+
gypsum wallboard 0.5 in thick
|
2246
|
+
",NECB_2017
|
2247
|
+
258,ROOF,BTAP-ExteriorRoof-Metal-2,BTAP,7,ExteriorRoof,Metal,2,Zone 8,8.26,"Steel Roofing, painted galvanized Attic Insulation","95,96,97,80,80,80,150,3,1","Zinc Steel roofing, 28 gauge, .020"" thick, 115 lb/ft2
|
2248
|
+
Asphalt felt, #15
|
2249
|
+
Plywood underlayment 0.75' thick
|
2250
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2251
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2252
|
+
XPS, 25 PSI, 3"" RSI 2.64
|
2253
|
+
XPS, 25 PSI, 1"" RSI 0.88
|
2254
|
+
polyethylene 4 ml vapour barrier
|
2255
|
+
gypsum wallboard 0.5 in thick
|
2256
|
+
",NECB_2017
|