openstudio-standards 0.8.2 → 0.8.3
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- checksums.yaml +4 -4
- data/data/standards/OpenStudio_Standards-ashrae_90_1-ALL-comstock(space_types).xlsx +0 -0
- data/data/standards/openstudio_standards_duplicates_log.csv +7962 -0
- data/lib/openstudio-standards/refrigeration/create_case.rb +58 -21
- data/lib/openstudio-standards/refrigeration/create_typical_refrigeration.rb +4 -2
- data/lib/openstudio-standards/refrigeration/create_walkin.rb +57 -22
- data/lib/openstudio-standards/refrigeration/data/refrigerated_cases.csv +31 -31
- data/lib/openstudio-standards/refrigeration/data/refrigerated_walkins.csv +76 -76
- data/lib/openstudio-standards/service_water_heating/create_typical.rb +10 -10
- data/lib/openstudio-standards/service_water_heating/create_water_heater.rb +10 -0
- data/lib/openstudio-standards/service_water_heating/create_water_heating_loop.rb +16 -3
- data/lib/openstudio-standards/service_water_heating/data/convert_data.rb +9 -9
- data/lib/openstudio-standards/service_water_heating/data/typical_water_use_equipment.csv +49 -49
- data/lib/openstudio-standards/service_water_heating/data/typical_water_use_equipment.json +159 -159
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +7 -18
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +10 -20
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +6 -15
- data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +5 -6
- data/lib/openstudio-standards/standards/Standards.CoilDX.rb +93 -43
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +5 -5
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +135 -37
- data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.Model.rb +9 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.computer_room_acs.json +302 -140
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps.json +648 -326
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +371 -90
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_heaters.json +66 -22
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.computer_room_acs.json +302 -140
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps.json +1012 -296
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +443 -79
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_heaters.json +66 -22
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.computer_room_acs.json +302 -140
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps.json +672 -306
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +354 -74
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_heaters.json +72 -24
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.computer_room_acs.json +302 -140
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +8 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps.json +930 -604
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +415 -111
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_heaters.json +72 -24
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.computer_room_acs.json +602 -140
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps.json +1005 -333
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps_heating.json +642 -88
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.water_heaters.json +78 -26
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.computer_room_acs.json +722 -140
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps.json +1741 -426
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps_heating.json +1108 -111
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.water_heaters.json +186 -62
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.schedules.json +62 -232
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXSingleSpeed.rb +2 -3
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXTwoSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb +7 -18
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingDXSingleSpeed.rb +9 -7
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingGas.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.heat_pumps.json +154 -69
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.heat_pumps_heating.json +72 -72
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.water_heaters.json +382 -295
- data/lib/openstudio-standards/standards/deer/data/deer.schedules.json +62 -232
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/heat_pumps.json +16 -0
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/heat_pumps_heating.json +6 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/heat_pumps.json +16 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/heat_pumps_heating.json +6 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +2 -2
- data/lib/openstudio-standards/standards/necb/NECB2015/data/heat_pumps.json +16 -0
- data/lib/openstudio-standards/standards/necb/NECB2015/data/heat_pumps_heating.json +8 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps.json +20 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps_heating.json +10 -0
- data/lib/openstudio-standards/utilities/simulation.rb +3 -2
- data/lib/openstudio-standards/version.rb +1 -1
- metadata +5 -3
@@ -1,119 +1,204 @@
|
|
1
1
|
{
|
2
2
|
"heat_pumps": [
|
3
3
|
{
|
4
|
-
"
|
4
|
+
"equipment_type": "PTHP",
|
5
5
|
"cooling_type": "AirCooled",
|
6
6
|
"heating_type": "Any",
|
7
|
-
"
|
8
|
-
"
|
9
|
-
"
|
7
|
+
"configuration": null,
|
8
|
+
"subcategory": null,
|
9
|
+
"application": null,
|
10
|
+
"rating_condition": null,
|
11
|
+
"electric_power_phase": null,
|
12
|
+
"region": null,
|
13
|
+
"minimum_capacity": 0,
|
14
|
+
"maximum_capacity": 9999999999,
|
10
15
|
"start_date": "1919-09-09T00:00:00+00:00",
|
11
16
|
"end_date": "2999-09-09T00:00:00+00:00",
|
12
|
-
"
|
13
|
-
"
|
14
|
-
"
|
17
|
+
"minimum_seasonal_energy_efficiency_ratio": null,
|
18
|
+
"minimum_seasonal_energy_efficiency_ratio_2": null,
|
19
|
+
"minimum_energy_efficiency_ratio": null,
|
20
|
+
"minimum_integrated_part_load_value": null,
|
15
21
|
"minimum_integrated_energy_efficiency_ratio": null,
|
22
|
+
"minimum_combined_energy_efficiency_ratio": null,
|
16
23
|
"pthp_eer_coefficient_1": null,
|
17
24
|
"pthp_eer_coefficient_2": null,
|
18
|
-
"
|
19
|
-
"
|
20
|
-
"cool_cap_fflow": null,
|
21
|
-
"cool_eir_ft": null,
|
22
|
-
"cool_eir_fflow": null,
|
23
|
-
"cool_plf_fplr": null,
|
24
|
-
"notes": null
|
25
|
+
"off_mode_power": null,
|
26
|
+
"minimum_coefficient_of_performance_no_fan_cooling": 3.1
|
25
27
|
},
|
26
28
|
{
|
27
|
-
"
|
29
|
+
"equipment_type": "Heat Pumps",
|
28
30
|
"cooling_type": "AirCooled",
|
29
31
|
"heating_type": "Any",
|
32
|
+
"configuration": null,
|
30
33
|
"subcategory": "Single Package",
|
31
|
-
"
|
32
|
-
"
|
34
|
+
"application": null,
|
35
|
+
"rating_condition": null,
|
36
|
+
"electric_power_phase": null,
|
37
|
+
"region": null,
|
38
|
+
"minimum_capacity": 0,
|
39
|
+
"maximum_capacity": 64999.99,
|
33
40
|
"start_date": "1919-09-09T00:00:00+00:00",
|
34
41
|
"end_date": "2999-09-09T00:00:00+00:00",
|
35
|
-
"
|
36
|
-
"
|
37
|
-
"
|
42
|
+
"minimum_seasonal_energy_efficiency_ratio": null,
|
43
|
+
"minimum_seasonal_energy_efficiency_ratio_2": null,
|
44
|
+
"minimum_energy_efficiency_ratio": null,
|
45
|
+
"minimum_integrated_part_load_value": null,
|
38
46
|
"minimum_integrated_energy_efficiency_ratio": null,
|
47
|
+
"minimum_combined_energy_efficiency_ratio": null,
|
39
48
|
"pthp_eer_coefficient_1": null,
|
40
49
|
"pthp_eer_coefficient_2": null,
|
41
|
-
"
|
42
|
-
"
|
43
|
-
"cool_cap_fflow": null,
|
44
|
-
"cool_eir_ft": null,
|
45
|
-
"cool_eir_fflow": null,
|
46
|
-
"cool_plf_fplr": null,
|
47
|
-
"notes": null
|
50
|
+
"off_mode_power": null,
|
51
|
+
"minimum_coefficient_of_performance_no_fan_cooling": 3
|
48
52
|
},
|
49
53
|
{
|
50
|
-
"
|
54
|
+
"equipment_type": "Heat Pumps",
|
51
55
|
"cooling_type": "AirCooled",
|
52
56
|
"heating_type": "Any",
|
53
|
-
"
|
54
|
-
"
|
55
|
-
"
|
57
|
+
"configuration": null,
|
58
|
+
"subcategory": "Single Package",
|
59
|
+
"application": null,
|
60
|
+
"rating_condition": null,
|
61
|
+
"electric_power_phase": null,
|
62
|
+
"region": null,
|
63
|
+
"minimum_capacity": 65000,
|
64
|
+
"maximum_capacity": 134999.99,
|
65
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
66
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
67
|
+
"minimum_seasonal_energy_efficiency_ratio": null,
|
68
|
+
"minimum_seasonal_energy_efficiency_ratio_2": null,
|
69
|
+
"minimum_energy_efficiency_ratio": null,
|
70
|
+
"minimum_integrated_part_load_value": null,
|
71
|
+
"minimum_integrated_energy_efficiency_ratio": null,
|
72
|
+
"minimum_combined_energy_efficiency_ratio": null,
|
73
|
+
"pthp_eer_coefficient_1": null,
|
74
|
+
"pthp_eer_coefficient_2": null,
|
75
|
+
"off_mode_power": null,
|
76
|
+
"minimum_coefficient_of_performance_no_fan_cooling": 3.4
|
77
|
+
},
|
78
|
+
{
|
79
|
+
"equipment_type": "Heat Pumps",
|
80
|
+
"cooling_type": "AirCooled",
|
81
|
+
"heating_type": "Any",
|
82
|
+
"configuration": null,
|
83
|
+
"subcategory": "Single Package",
|
84
|
+
"application": null,
|
85
|
+
"rating_condition": null,
|
86
|
+
"electric_power_phase": null,
|
87
|
+
"region": null,
|
88
|
+
"minimum_capacity": 135000,
|
89
|
+
"maximum_capacity": 239999.99,
|
90
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
91
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
92
|
+
"minimum_seasonal_energy_efficiency_ratio": null,
|
93
|
+
"minimum_seasonal_energy_efficiency_ratio_2": null,
|
94
|
+
"minimum_energy_efficiency_ratio": null,
|
95
|
+
"minimum_integrated_part_load_value": null,
|
96
|
+
"minimum_integrated_energy_efficiency_ratio": null,
|
97
|
+
"minimum_combined_energy_efficiency_ratio": null,
|
98
|
+
"pthp_eer_coefficient_1": null,
|
99
|
+
"pthp_eer_coefficient_2": null,
|
100
|
+
"off_mode_power": null,
|
101
|
+
"minimum_coefficient_of_performance_no_fan_cooling": 3.2
|
102
|
+
},
|
103
|
+
{
|
104
|
+
"equipment_type": "Heat Pumps",
|
105
|
+
"cooling_type": "AirCooled",
|
106
|
+
"heating_type": "Any",
|
107
|
+
"configuration": null,
|
108
|
+
"subcategory": "Single Package",
|
109
|
+
"application": null,
|
110
|
+
"rating_condition": null,
|
111
|
+
"electric_power_phase": null,
|
112
|
+
"region": null,
|
113
|
+
"minimum_capacity": 240000,
|
114
|
+
"maximum_capacity": 9999999999,
|
115
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
116
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
117
|
+
"minimum_seasonal_energy_efficiency_ratio": null,
|
118
|
+
"minimum_seasonal_energy_efficiency_ratio_2": null,
|
119
|
+
"minimum_energy_efficiency_ratio": null,
|
120
|
+
"minimum_integrated_part_load_value": null,
|
121
|
+
"minimum_integrated_energy_efficiency_ratio": null,
|
122
|
+
"minimum_combined_energy_efficiency_ratio": null,
|
123
|
+
"pthp_eer_coefficient_1": null,
|
124
|
+
"pthp_eer_coefficient_2": null,
|
125
|
+
"off_mode_power": null,
|
126
|
+
"minimum_coefficient_of_performance_no_fan_cooling": 3.1
|
127
|
+
},
|
128
|
+
{
|
129
|
+
"equipment_type": "Heat Pumps",
|
130
|
+
"cooling_type": "AirCooled",
|
131
|
+
"heating_type": "Any",
|
132
|
+
"configuration": null,
|
133
|
+
"subcategory": "Split System",
|
134
|
+
"application": null,
|
135
|
+
"rating_condition": null,
|
136
|
+
"electric_power_phase": null,
|
137
|
+
"region": null,
|
138
|
+
"minimum_capacity": 65000,
|
139
|
+
"maximum_capacity": 134999.99,
|
56
140
|
"start_date": "1919-09-09T00:00:00+00:00",
|
57
141
|
"end_date": "2999-09-09T00:00:00+00:00",
|
58
|
-
"
|
59
|
-
"
|
60
|
-
"
|
142
|
+
"minimum_seasonal_energy_efficiency_ratio": null,
|
143
|
+
"minimum_seasonal_energy_efficiency_ratio_2": null,
|
144
|
+
"minimum_energy_efficiency_ratio": null,
|
145
|
+
"minimum_integrated_part_load_value": null,
|
61
146
|
"minimum_integrated_energy_efficiency_ratio": null,
|
147
|
+
"minimum_combined_energy_efficiency_ratio": null,
|
62
148
|
"pthp_eer_coefficient_1": null,
|
63
149
|
"pthp_eer_coefficient_2": null,
|
64
|
-
"
|
65
|
-
"
|
66
|
-
"cool_cap_fflow": null,
|
67
|
-
"cool_eir_ft": null,
|
68
|
-
"cool_eir_fflow": null,
|
69
|
-
"cool_plf_fplr": null,
|
70
|
-
"notes": null
|
150
|
+
"off_mode_power": null,
|
151
|
+
"minimum_coefficient_of_performance_no_fan_cooling": 3.4
|
71
152
|
},
|
72
153
|
{
|
73
|
-
"
|
154
|
+
"equipment_type": "Heat Pumps",
|
74
155
|
"cooling_type": "AirCooled",
|
75
156
|
"heating_type": "Any",
|
76
|
-
"
|
77
|
-
"
|
78
|
-
"
|
157
|
+
"configuration": null,
|
158
|
+
"subcategory": "Split System",
|
159
|
+
"application": null,
|
160
|
+
"rating_condition": null,
|
161
|
+
"electric_power_phase": null,
|
162
|
+
"region": null,
|
163
|
+
"minimum_capacity": 135000,
|
164
|
+
"maximum_capacity": 239999.99,
|
79
165
|
"start_date": "1919-09-09T00:00:00+00:00",
|
80
166
|
"end_date": "2999-09-09T00:00:00+00:00",
|
81
|
-
"
|
82
|
-
"
|
83
|
-
"
|
167
|
+
"minimum_seasonal_energy_efficiency_ratio": null,
|
168
|
+
"minimum_seasonal_energy_efficiency_ratio_2": null,
|
169
|
+
"minimum_energy_efficiency_ratio": null,
|
170
|
+
"minimum_integrated_part_load_value": null,
|
84
171
|
"minimum_integrated_energy_efficiency_ratio": null,
|
172
|
+
"minimum_combined_energy_efficiency_ratio": null,
|
85
173
|
"pthp_eer_coefficient_1": null,
|
86
174
|
"pthp_eer_coefficient_2": null,
|
87
|
-
"
|
88
|
-
"
|
89
|
-
"cool_cap_fflow": null,
|
90
|
-
"cool_eir_ft": null,
|
91
|
-
"cool_eir_fflow": null,
|
92
|
-
"cool_plf_fplr": null,
|
93
|
-
"notes": null
|
175
|
+
"off_mode_power": null,
|
176
|
+
"minimum_coefficient_of_performance_no_fan_cooling": 3.2
|
94
177
|
},
|
95
178
|
{
|
96
|
-
"
|
179
|
+
"equipment_type": "Heat Pumps",
|
97
180
|
"cooling_type": "AirCooled",
|
98
181
|
"heating_type": "Any",
|
99
|
-
"
|
100
|
-
"
|
101
|
-
"
|
182
|
+
"configuration": null,
|
183
|
+
"subcategory": "Split System",
|
184
|
+
"application": null,
|
185
|
+
"rating_condition": null,
|
186
|
+
"electric_power_phase": null,
|
187
|
+
"region": null,
|
188
|
+
"minimum_capacity": 240000,
|
189
|
+
"maximum_capacity": 9999999999,
|
102
190
|
"start_date": "1919-09-09T00:00:00+00:00",
|
103
191
|
"end_date": "2999-09-09T00:00:00+00:00",
|
104
|
-
"
|
105
|
-
"
|
106
|
-
"
|
192
|
+
"minimum_seasonal_energy_efficiency_ratio": null,
|
193
|
+
"minimum_seasonal_energy_efficiency_ratio_2": null,
|
194
|
+
"minimum_energy_efficiency_ratio": null,
|
195
|
+
"minimum_integrated_part_load_value": null,
|
107
196
|
"minimum_integrated_energy_efficiency_ratio": null,
|
197
|
+
"minimum_combined_energy_efficiency_ratio": null,
|
108
198
|
"pthp_eer_coefficient_1": null,
|
109
199
|
"pthp_eer_coefficient_2": null,
|
110
|
-
"
|
111
|
-
"
|
112
|
-
"cool_cap_fflow": null,
|
113
|
-
"cool_eir_ft": null,
|
114
|
-
"cool_eir_fflow": null,
|
115
|
-
"cool_plf_fplr": null,
|
116
|
-
"notes": null
|
200
|
+
"off_mode_power": null,
|
201
|
+
"minimum_coefficient_of_performance_no_fan_cooling": 3.1
|
117
202
|
}
|
118
203
|
]
|
119
204
|
}
|
@@ -1,130 +1,130 @@
|
|
1
1
|
{
|
2
2
|
"heat_pumps_heating": [
|
3
3
|
{
|
4
|
-
"
|
4
|
+
"equipment_type": "PTHP",
|
5
5
|
"cooling_type": "AirCooled",
|
6
|
-
"
|
7
|
-
"
|
8
|
-
"
|
6
|
+
"configuration": null,
|
7
|
+
"subcategory": null,
|
8
|
+
"application": null,
|
9
|
+
"rating_condition": null,
|
10
|
+
"electric_power_phase": null,
|
11
|
+
"region": null,
|
12
|
+
"minimum_capacity": 0,
|
13
|
+
"maximum_capacity": 9999999999,
|
9
14
|
"start_date": "1919-09-09T00:00:00+00:00",
|
10
15
|
"end_date": "2999-09-09T00:00:00+00:00",
|
11
16
|
"minimum_heating_seasonal_performance_factor": null,
|
17
|
+
"minimum_heating_seasonal_performance_factor_2": null,
|
12
18
|
"minimum_coefficient_of_performance_heating": null,
|
13
|
-
"minimum_energy_efficiency_ratio": null,
|
14
19
|
"pthp_cop_coefficient_1": null,
|
15
20
|
"pthp_cop_coefficient_2": null,
|
16
|
-
"
|
17
|
-
"
|
18
|
-
"heat_cap_fflow": null,
|
19
|
-
"heat_eir_ft": null,
|
20
|
-
"heat_eir_fflow": null,
|
21
|
-
"heat_plf_fplr": null,
|
22
|
-
"notes": null
|
21
|
+
"off_mode_power": null,
|
22
|
+
"minimum_coefficient_of_performance_no_fan_heating": 3.1
|
23
23
|
},
|
24
24
|
{
|
25
|
-
"
|
25
|
+
"equipment_type": "Heat Pumps",
|
26
26
|
"cooling_type": "AirCooled",
|
27
|
-
"
|
28
|
-
"
|
29
|
-
"
|
27
|
+
"configuration": null,
|
28
|
+
"subcategory": "Single Package",
|
29
|
+
"application": null,
|
30
|
+
"rating_condition": null,
|
31
|
+
"electric_power_phase": null,
|
32
|
+
"region": null,
|
33
|
+
"minimum_capacity": 0,
|
34
|
+
"maximum_capacity": 64999.99,
|
30
35
|
"start_date": "1919-09-09T00:00:00+00:00",
|
31
36
|
"end_date": "2999-09-09T00:00:00+00:00",
|
32
37
|
"minimum_heating_seasonal_performance_factor": null,
|
38
|
+
"minimum_heating_seasonal_performance_factor_2": null,
|
33
39
|
"minimum_coefficient_of_performance_heating": null,
|
34
|
-
"minimum_energy_efficiency_ratio": null,
|
35
40
|
"pthp_cop_coefficient_1": null,
|
36
41
|
"pthp_cop_coefficient_2": null,
|
37
|
-
"
|
38
|
-
"
|
39
|
-
"heat_cap_fflow": null,
|
40
|
-
"heat_eir_ft": null,
|
41
|
-
"heat_eir_fflow": null,
|
42
|
-
"heat_plf_fplr": null,
|
43
|
-
"notes": null
|
42
|
+
"off_mode_power": null,
|
43
|
+
"minimum_coefficient_of_performance_no_fan_heating": 3.4
|
44
44
|
},
|
45
45
|
{
|
46
|
-
"
|
46
|
+
"equipment_type": "Heat Pumps",
|
47
47
|
"cooling_type": "AirCooled",
|
48
|
-
"
|
49
|
-
"
|
50
|
-
"
|
48
|
+
"configuration": null,
|
49
|
+
"subcategory": null,
|
50
|
+
"application": null,
|
51
|
+
"rating_condition": "47F db/43F wb outdoor air",
|
52
|
+
"electric_power_phase": null,
|
53
|
+
"region": null,
|
54
|
+
"minimum_capacity": 65000,
|
55
|
+
"maximum_capacity": 134999.99,
|
51
56
|
"start_date": "1919-09-09T00:00:00+00:00",
|
52
57
|
"end_date": "2999-09-09T00:00:00+00:00",
|
53
58
|
"minimum_heating_seasonal_performance_factor": null,
|
59
|
+
"minimum_heating_seasonal_performance_factor_2": null,
|
54
60
|
"minimum_coefficient_of_performance_heating": null,
|
55
|
-
"minimum_energy_efficiency_ratio": null,
|
56
61
|
"pthp_cop_coefficient_1": null,
|
57
62
|
"pthp_cop_coefficient_2": null,
|
58
|
-
"
|
59
|
-
"
|
60
|
-
"heat_cap_fflow": null,
|
61
|
-
"heat_eir_ft": null,
|
62
|
-
"heat_eir_fflow": null,
|
63
|
-
"heat_plf_fplr": null,
|
64
|
-
"notes": null
|
63
|
+
"off_mode_power": null,
|
64
|
+
"minimum_coefficient_of_performance_no_fan_heating": 3.4
|
65
65
|
},
|
66
66
|
{
|
67
|
-
"
|
67
|
+
"equipment_type": "Heat Pumps",
|
68
68
|
"cooling_type": "AirCooled",
|
69
|
-
"
|
70
|
-
"
|
71
|
-
"
|
69
|
+
"configuration": null,
|
70
|
+
"subcategory": null,
|
71
|
+
"application": null,
|
72
|
+
"rating_condition": "17F db/15F wb outdoor air",
|
73
|
+
"electric_power_phase": null,
|
74
|
+
"region": null,
|
75
|
+
"minimum_capacity": 65000,
|
76
|
+
"maximum_capacity": 134999.99,
|
72
77
|
"start_date": "1919-09-09T00:00:00+00:00",
|
73
78
|
"end_date": "2999-09-09T00:00:00+00:00",
|
74
79
|
"minimum_heating_seasonal_performance_factor": null,
|
80
|
+
"minimum_heating_seasonal_performance_factor_2": null,
|
75
81
|
"minimum_coefficient_of_performance_heating": null,
|
76
|
-
"minimum_energy_efficiency_ratio": null,
|
77
82
|
"pthp_cop_coefficient_1": null,
|
78
83
|
"pthp_cop_coefficient_2": null,
|
79
|
-
"
|
80
|
-
"
|
81
|
-
"heat_cap_fflow": null,
|
82
|
-
"heat_eir_ft": null,
|
83
|
-
"heat_eir_fflow": null,
|
84
|
-
"heat_plf_fplr": null,
|
85
|
-
"notes": null
|
84
|
+
"off_mode_power": null,
|
85
|
+
"minimum_coefficient_of_performance_no_fan_heating": 2.3
|
86
86
|
},
|
87
87
|
{
|
88
|
-
"
|
88
|
+
"equipment_type": "Heat Pumps",
|
89
89
|
"cooling_type": "AirCooled",
|
90
|
-
"
|
91
|
-
"
|
92
|
-
"
|
90
|
+
"configuration": null,
|
91
|
+
"subcategory": null,
|
92
|
+
"application": null,
|
93
|
+
"rating_condition": "47F db/43F wb outdoor air",
|
94
|
+
"electric_power_phase": null,
|
95
|
+
"region": null,
|
96
|
+
"minimum_capacity": 135000,
|
97
|
+
"maximum_capacity": 9999999999,
|
93
98
|
"start_date": "1919-09-09T00:00:00+00:00",
|
94
99
|
"end_date": "2999-09-09T00:00:00+00:00",
|
95
100
|
"minimum_heating_seasonal_performance_factor": null,
|
101
|
+
"minimum_heating_seasonal_performance_factor_2": null,
|
96
102
|
"minimum_coefficient_of_performance_heating": null,
|
97
|
-
"minimum_energy_efficiency_ratio": null,
|
98
103
|
"pthp_cop_coefficient_1": null,
|
99
104
|
"pthp_cop_coefficient_2": null,
|
100
|
-
"
|
101
|
-
"
|
102
|
-
"heat_cap_fflow": null,
|
103
|
-
"heat_eir_ft": null,
|
104
|
-
"heat_eir_fflow": null,
|
105
|
-
"heat_plf_fplr": null,
|
106
|
-
"notes": null
|
105
|
+
"off_mode_power": null,
|
106
|
+
"minimum_coefficient_of_performance_no_fan_heating": 3.4
|
107
107
|
},
|
108
108
|
{
|
109
|
-
"
|
109
|
+
"equipment_type": "Heat Pumps",
|
110
110
|
"cooling_type": "AirCooled",
|
111
|
-
"
|
112
|
-
"
|
113
|
-
"
|
111
|
+
"configuration": null,
|
112
|
+
"subcategory": null,
|
113
|
+
"application": null,
|
114
|
+
"rating_condition": "17F db/15F wb outdoor air",
|
115
|
+
"electric_power_phase": null,
|
116
|
+
"region": null,
|
117
|
+
"minimum_capacity": 135000,
|
118
|
+
"maximum_capacity": 9999999999,
|
114
119
|
"start_date": "1919-09-09T00:00:00+00:00",
|
115
120
|
"end_date": "2999-09-09T00:00:00+00:00",
|
116
121
|
"minimum_heating_seasonal_performance_factor": null,
|
122
|
+
"minimum_heating_seasonal_performance_factor_2": null,
|
117
123
|
"minimum_coefficient_of_performance_heating": null,
|
118
|
-
"minimum_energy_efficiency_ratio": null,
|
119
124
|
"pthp_cop_coefficient_1": null,
|
120
125
|
"pthp_cop_coefficient_2": null,
|
121
|
-
"
|
122
|
-
"
|
123
|
-
"heat_cap_fflow": null,
|
124
|
-
"heat_eir_ft": null,
|
125
|
-
"heat_eir_fflow": null,
|
126
|
-
"heat_plf_fplr": null,
|
127
|
-
"notes": null
|
126
|
+
"off_mode_power": null,
|
127
|
+
"minimum_coefficient_of_performance_no_fan_heating": 2.1
|
128
128
|
}
|
129
129
|
]
|
130
130
|
}
|