openstudio-standards 0.7.1 → 0.8.0.rc2

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (363) hide show
  1. checksums.yaml +4 -4
  2. data/data/geometry/ASHRAE90120162019LargeHotel.json +58 -13
  3. data/data/geometry/ASHRAELargeHotel.json +58 -13
  4. data/data/standards/OpenStudio_Standards-ashrae_90_1-ALL-comstock(space_types).xlsx +0 -0
  5. data/data/standards/export_OpenStudio_libraries.rb +2 -2
  6. data/data/standards/manage_OpenStudio_Standards.rb +6 -6
  7. data/data/standards/openstudio_standards_duplicates_log.csv +7961 -1
  8. data/data/standards/test_performance_expected_dd_results.csv +2016 -2004
  9. data/lib/openstudio-standards/btap/fileio.rb +171 -5
  10. data/lib/openstudio-standards/constructions/create.rb +38 -4
  11. data/lib/openstudio-standards/constructions/modify.rb +10 -3
  12. data/lib/openstudio-standards/create_typical/create_typical.rb +42 -28
  13. data/lib/openstudio-standards/create_typical/space_type_information.rb +160 -0
  14. data/lib/openstudio-standards/create_typical/space_type_ratios.rb +22 -21
  15. data/lib/openstudio-standards/exterior_lighting/create.rb +454 -0
  16. data/lib/openstudio-standards/exterior_lighting/data/entryways.csv +52 -0
  17. data/lib/openstudio-standards/exterior_lighting/data/parking.csv +54 -0
  18. data/lib/openstudio-standards/exterior_lighting/data/typical_exterior_lighting.json +37 -0
  19. data/lib/openstudio-standards/exterior_lighting/information.rb +202 -0
  20. data/lib/openstudio-standards/geometry/information.rb +49 -2
  21. data/lib/openstudio-standards/hvac/components/create.rb +169 -0
  22. data/lib/openstudio-standards/hvac/components/modify.rb +42 -0
  23. data/lib/openstudio-standards/hvac/exhaust/create_exhaust_fan.rb +108 -0
  24. data/lib/openstudio-standards/hvac/exhaust/data/convert_data.rb +86 -0
  25. data/lib/openstudio-standards/hvac/exhaust/data/typical_exhaust.csv +18 -0
  26. data/lib/openstudio-standards/hvac/exhaust/data/typical_exhaust.json +89 -0
  27. data/lib/openstudio-standards/infiltration/nist_infiltration.rb +25 -13
  28. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +0 -64
  29. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +0 -25
  30. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +0 -25
  31. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Warehouse.rb +1 -11
  32. data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +5 -1
  33. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CentralAirSourceHeatPump.rb +1 -1
  34. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +0 -7
  35. data/lib/openstudio-standards/prototypes/common/objects/Prototype.HeatExchangerAirToAirSensibleAndLatent.rb +36 -18
  36. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +1 -1
  37. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +121 -239
  38. data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +179 -151
  39. data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +0 -466
  40. data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +18 -2
  41. data/lib/openstudio-standards/refrigeration/create_case.rb +125 -0
  42. data/lib/openstudio-standards/refrigeration/create_compressor.rb +78 -0
  43. data/lib/openstudio-standards/refrigeration/create_compressor_rack.rb +48 -0
  44. data/lib/openstudio-standards/refrigeration/create_refrigeration_system.rb +74 -0
  45. data/lib/openstudio-standards/refrigeration/create_typical_refrigeration.rb +161 -0
  46. data/lib/openstudio-standards/refrigeration/create_walkin.rb +116 -0
  47. data/lib/openstudio-standards/refrigeration/data/refrigerated_cases.csv +31 -0
  48. data/lib/openstudio-standards/refrigeration/data/refrigerated_walkins.csv +76 -0
  49. data/lib/openstudio-standards/refrigeration/data/refrigeration_compressors.csv +13 -0
  50. data/lib/openstudio-standards/refrigeration/data/typical_refrigerated_cases.csv +17 -0
  51. data/lib/openstudio-standards/refrigeration/data/typical_refrigerated_walkins.csv +53 -0
  52. data/lib/openstudio-standards/refrigeration/information.rb +130 -0
  53. data/lib/openstudio-standards/schedules/parametric.rb +1 -1
  54. data/lib/openstudio-standards/service_water_heating/create_typical.rb +299 -0
  55. data/lib/openstudio-standards/service_water_heating/create_water_heating_loop.rb +16 -14
  56. data/lib/openstudio-standards/service_water_heating/data/convert_data.rb +119 -0
  57. data/lib/openstudio-standards/service_water_heating/data/typical_water_use_equipment.csv +54 -0
  58. data/lib/openstudio-standards/service_water_heating/data/typical_water_use_equipment.json +810 -0
  59. data/lib/openstudio-standards/service_water_heating/information.rb +69 -0
  60. data/lib/openstudio-standards/sql_file/fenestration.rb +1 -1
  61. data/lib/openstudio-standards/standards/Standards.AirConditionerVariableRefrigerantFlow.rb +154 -0
  62. data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +35 -12
  63. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +110 -61
  64. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +128 -29
  65. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +103 -38
  66. data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +1 -1
  67. data/lib/openstudio-standards/standards/Standards.CoilDX.rb +106 -5
  68. data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +8 -8
  69. data/lib/openstudio-standards/standards/Standards.CoolingTower.rb +44 -17
  70. data/lib/openstudio-standards/standards/Standards.Fan.rb +32 -21
  71. data/lib/openstudio-standards/standards/Standards.FluidCooler.rb +45 -18
  72. data/lib/openstudio-standards/standards/Standards.HeatExchangerSensLat.rb +14 -9
  73. data/lib/openstudio-standards/standards/Standards.Model.rb +294 -76
  74. data/lib/openstudio-standards/standards/Standards.Motor.rb +66 -0
  75. data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +2 -1
  76. data/lib/openstudio-standards/standards/Standards.Pump.rb +34 -20
  77. data/lib/openstudio-standards/standards/Standards.ServiceWaterHeating.rb +0 -353
  78. data/lib/openstudio-standards/standards/Standards.Space.rb +3 -107
  79. data/lib/openstudio-standards/standards/Standards.SpaceType.rb +2 -57
  80. data/lib/openstudio-standards/standards/Standards.Surface.rb +11 -3
  81. data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +1 -120
  82. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.computer_room_acs.json +142 -0
  83. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.economizers.json +1006 -596
  84. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.energy_recovery.json +724 -0
  85. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ext_ltg.json +1258 -163
  86. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.motors.json +1070 -140
  87. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +33 -3374
  88. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.unitary_acs.json +1400 -340
  89. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.vrfs.json +769 -0
  90. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.spc_typ.json +2 -5338
  91. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.computer_room_acs.json +142 -0
  92. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.economizers.json +1006 -596
  93. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.energy_recovery.json +724 -0
  94. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ext_ltg.json +1258 -163
  95. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.motors.json +1070 -140
  96. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +15 -3343
  97. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.unitary_acs.json +1840 -372
  98. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.vrfs.json +769 -0
  99. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb +20 -10
  100. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb +0 -9
  101. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.spc_typ.json +0 -5382
  102. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.computer_room_acs.json +142 -0
  103. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.economizers.json +1006 -628
  104. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +718 -712
  105. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ext_ltg.json +1438 -163
  106. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.motors.json +2552 -182
  107. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +14 -3368
  108. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.unitary_acs.json +2348 -352
  109. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.vrfs.json +769 -0
  110. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirLoopHVAC.rb +47 -61
  111. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +6 -0
  112. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Motor.rb +11 -0
  113. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Space.rb +0 -9
  114. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.spc_typ.json +2 -5522
  115. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.computer_room_acs.json +142 -0
  116. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.economizers.json +1006 -628
  117. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +1358 -1346
  118. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ext_ltg.json +1438 -163
  119. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.motors.json +1359 -189
  120. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +19 -3451
  121. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.unitary_acs.json +2176 -616
  122. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.vrfs.json +616 -0
  123. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirLoopHVAC.rb +47 -61
  124. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +9 -0
  125. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Motor.rb +11 -0
  126. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Space.rb +0 -9
  127. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.spc_typ.json +8 -6055
  128. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.computer_room_acs.json +142 -0
  129. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.economizers.json +1006 -628
  130. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.energy_recovery.json +1188 -1424
  131. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.ext_ltg.json +1498 -163
  132. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.motors.json +1769 -189
  133. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +15 -3422
  134. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.unitary_acs.json +1807 -408
  135. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.vrfs.json +1024 -0
  136. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +70 -87
  137. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +9 -0
  138. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Motor.rb +11 -0
  139. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +0 -9
  140. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.spc_typ.json +8 -6080
  141. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.computer_room_acs.json +142 -0
  142. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.economizers.json +1006 -628
  143. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.energy_recovery.json +2806 -3296
  144. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.ext_ltg.json +1558 -163
  145. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.motors.json +1759 -189
  146. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +16 -3448
  147. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.unitary_acs.json +2758 -422
  148. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.vrfs.json +684 -0
  149. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.schedules.json +14 -3318
  150. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.spc_typ.json +2 -4786
  151. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.chillers.json +1 -1
  152. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.economizers.json +953 -207
  153. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.energy_recovery.json +724 -0
  154. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.ext_ltg.json +5 -5
  155. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +11 -2858
  156. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirConditionerVariableRefrigerantFlow.rb +13 -0
  157. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb +0 -18
  158. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.spc_typ.json +1 -4739
  159. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.chillers.json +0 -51
  160. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.economizers.json +953 -207
  161. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.energy_recovery.json +724 -0
  162. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.ext_ltg.json +5 -5
  163. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +9 -2830
  164. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirConditionerVariableRefrigerantFlow.rb +13 -0
  165. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb +0 -18
  166. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.economizers.json +1006 -564
  167. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.energy_recovery.json +1264 -0
  168. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.ext_ltg.json +5 -5
  169. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.spc_typ.json +0 -1079
  170. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +132 -288
  171. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.HeatExchangerSensLat.rb +44 -20
  172. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Model.rb +11 -0
  173. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Space.rb +0 -8
  174. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.economizers.json +1006 -564
  175. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.energy_recovery.json +1264 -0
  176. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.ext_ltg.json +5 -5
  177. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.spc_typ.json +0 -1079
  178. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb +137 -288
  179. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerSensLat.rb +44 -20
  180. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +11 -0
  181. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Space.rb +0 -9
  182. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirLoopHVAC.rb +12 -10
  183. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXSingleSpeed.rb +8 -6
  184. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXTwoSpeed.rb +8 -6
  185. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb +9 -3
  186. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Fan.rb +6 -40
  187. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Model.rb +30 -337
  188. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Space.rb +4 -5
  189. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.SpaceType.rb +1 -2
  190. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.rb +56 -3
  191. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.Model.rb +80 -0
  192. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.rb +0 -10
  193. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019_WaterHeaterMixed.rb +35 -0
  194. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.economizers.json +550 -0
  195. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.energy_recovery.json +724 -0
  196. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.ext_ltg.json +1216 -0
  197. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.heat_pumps.json +5 -5
  198. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.motors.json +225 -245
  199. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.unitary_acs.json +174 -78
  200. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.water_heaters.json +354 -317
  201. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_enums.rb +19 -3
  202. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_airloop_hvac.json +185 -0
  203. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_airloop_hvac_doas.json +127 -0
  204. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_building.json +121 -0
  205. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_design_specification_outdoor_air.json +49 -0
  206. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_electric_equipment.json +113 -0
  207. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_exterior_lights.json +120 -0
  208. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_space.json +388 -0
  209. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_spacetype.json +367 -0
  210. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_thermal_zone.json +56 -0
  211. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_wateruse_connections.json +37 -0
  212. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_wateruse_equipment.json +69 -0
  213. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_wateruse_equipment_definition.json +37 -0
  214. data/lib/openstudio-standards/standards/cbes/cbes_pre_1978/data/cbes_pre_1978.ext_ltg.json +5 -5
  215. data/lib/openstudio-standards/standards/cbes/cbes_t24_1978/data/cbes_t24_1978.ext_ltg.json +5 -5
  216. data/lib/openstudio-standards/standards/cbes/cbes_t24_1992/data/cbes_t24_1992.ext_ltg.json +5 -5
  217. data/lib/openstudio-standards/standards/cbes/cbes_t24_2001/data/cbes_t24_2001.ext_ltg.json +5 -5
  218. data/lib/openstudio-standards/standards/cbes/cbes_t24_2005/data/cbes_t24_2005.ext_ltg.json +5 -5
  219. data/lib/openstudio-standards/standards/cbes/cbes_t24_2008/data/cbes_t24_2008.ext_ltg.json +5 -5
  220. data/lib/openstudio-standards/standards/deer/deer_1985/comstock_deer_1985/data/comstock_deer_1985.ext_ltg.json +5 -5
  221. data/lib/openstudio-standards/standards/deer/deer_1985/data/deer_1985.ext_ltg.json +5 -5
  222. data/lib/openstudio-standards/standards/deer/deer_1996/comstock_deer_1996/data/comstock_deer_1996.ext_ltg.json +5 -5
  223. data/lib/openstudio-standards/standards/deer/deer_1996/data/deer_1996.ext_ltg.json +5 -5
  224. data/lib/openstudio-standards/standards/deer/deer_2003/comstock_deer_2003/data/comstock_deer_2003.ext_ltg.json +5 -5
  225. data/lib/openstudio-standards/standards/deer/deer_2003/data/deer_2003.ext_ltg.json +5 -5
  226. data/lib/openstudio-standards/standards/deer/deer_2007/comstock_deer_2007/data/comstock_deer_2007.ext_ltg.json +5 -5
  227. data/lib/openstudio-standards/standards/deer/deer_2007/data/deer_2007.ext_ltg.json +5 -5
  228. data/lib/openstudio-standards/standards/deer/deer_2011/comstock_deer_2011/data/comstock_deer_2011.ext_ltg.json +5 -5
  229. data/lib/openstudio-standards/standards/deer/deer_2011/data/deer_2011.ext_ltg.json +5 -5
  230. data/lib/openstudio-standards/standards/deer/deer_2014/comstock_deer_2014/data/comstock_deer_2014.ext_ltg.json +5 -5
  231. data/lib/openstudio-standards/standards/deer/deer_2014/data/deer_2014.ext_ltg.json +5 -5
  232. data/lib/openstudio-standards/standards/deer/deer_2015/comstock_deer_2015/data/comstock_deer_2015.ext_ltg.json +5 -5
  233. data/lib/openstudio-standards/standards/deer/deer_2015/data/deer_2015.ext_ltg.json +5 -5
  234. data/lib/openstudio-standards/standards/deer/deer_2017/comstock_deer_2017/data/comstock_deer_2017.ext_ltg.json +5 -5
  235. data/lib/openstudio-standards/standards/deer/deer_2017/data/deer_2017.ext_ltg.json +5 -5
  236. data/lib/openstudio-standards/standards/deer/deer_2020/comstock_deer_2020/data/comstock_deer_2020.ext_ltg.json +5 -5
  237. data/lib/openstudio-standards/standards/deer/deer_2020/data/deer_2020.ext_ltg.json +5 -5
  238. data/lib/openstudio-standards/standards/deer/deer_2025/comstock_deer_2025/data/comstock_deer_2025.ext_ltg.json +5 -5
  239. data/lib/openstudio-standards/standards/deer/deer_2025/data/deer_2025.ext_ltg.json +5 -5
  240. data/lib/openstudio-standards/standards/deer/deer_2030/comstock_deer_2030/data/comstock_deer_2030.ext_ltg.json +5 -5
  241. data/lib/openstudio-standards/standards/deer/deer_2030/data/deer_2030.ext_ltg.json +5 -5
  242. data/lib/openstudio-standards/standards/deer/deer_2035/comstock_deer_2035/data/comstock_deer_2035.ext_ltg.json +5 -5
  243. data/lib/openstudio-standards/standards/deer/deer_2035/data/deer_2035.ext_ltg.json +5 -5
  244. data/lib/openstudio-standards/standards/deer/deer_2040/comstock_deer_2040/data/comstock_deer_2040.ext_ltg.json +5 -5
  245. data/lib/openstudio-standards/standards/deer/deer_2040/data/deer_2040.ext_ltg.json +5 -5
  246. data/lib/openstudio-standards/standards/deer/deer_2045/comstock_deer_2045/data/comstock_deer_2045.ext_ltg.json +5 -5
  247. data/lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.ext_ltg.json +5 -5
  248. data/lib/openstudio-standards/standards/deer/deer_2050/comstock_deer_2050/data/comstock_deer_2050.ext_ltg.json +5 -5
  249. data/lib/openstudio-standards/standards/deer/deer_2050/data/deer_2050.ext_ltg.json +5 -5
  250. data/lib/openstudio-standards/standards/deer/deer_2055/comstock_deer_2055/data/comstock_deer_2055.ext_ltg.json +5 -5
  251. data/lib/openstudio-standards/standards/deer/deer_2055/data/deer_2055.ext_ltg.json +5 -5
  252. data/lib/openstudio-standards/standards/deer/deer_2060/comstock_deer_2060/data/comstock_deer_2060.ext_ltg.json +5 -5
  253. data/lib/openstudio-standards/standards/deer/deer_2060/data/deer_2060.ext_ltg.json +5 -5
  254. data/lib/openstudio-standards/standards/deer/deer_2065/comstock_deer_2065/data/comstock_deer_2065.ext_ltg.json +5 -5
  255. data/lib/openstudio-standards/standards/deer/deer_2065/data/deer_2065.ext_ltg.json +5 -5
  256. data/lib/openstudio-standards/standards/deer/deer_2070/comstock_deer_2070/data/comstock_deer_2070.ext_ltg.json +5 -5
  257. data/lib/openstudio-standards/standards/deer/deer_2070/data/deer_2070.ext_ltg.json +5 -5
  258. data/lib/openstudio-standards/standards/deer/deer_2075/comstock_deer_2075/data/comstock_deer_2075.ext_ltg.json +5 -5
  259. data/lib/openstudio-standards/standards/deer/deer_2075/data/deer_2075.ext_ltg.json +5 -5
  260. data/lib/openstudio-standards/standards/deer/deer_pre_1975/comstock_deer_pre_1975/data/comstock_deer_pre_1975.ext_ltg.json +5 -5
  261. data/lib/openstudio-standards/standards/deer/deer_pre_1975/data/deer_pre_1975.ext_ltg.json +5 -5
  262. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +10 -1
  263. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/unitary_acs.json +20 -20
  264. data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +379 -27
  265. data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +1 -4
  266. data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +0 -1
  267. data/lib/openstudio-standards/standards/necb/NECB2011/data/fuel_type_sets.json +1 -1
  268. data/lib/openstudio-standards/standards/necb/NECB2011/data/unitary_acs.json +20 -20
  269. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +34 -22
  270. data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +76 -23
  271. data/lib/openstudio-standards/standards/necb/NECB2011/necb_shw_calculation.xlsx +0 -0
  272. data/lib/openstudio-standards/standards/necb/NECB2011/service_water_heating.rb +4 -5
  273. data/lib/openstudio-standards/standards/necb/NECB2011/system_fuels.rb +6 -2
  274. data/lib/openstudio-standards/standards/necb/NECB2015/data/unitary_acs.json +26 -24
  275. data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +2 -1
  276. data/lib/openstudio-standards/standards/necb/NECB2020/data/unitary_acs.json +38 -32
  277. data/lib/openstudio-standards/standards/necb/common/btap_data.rb +215 -18
  278. data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +190 -15
  279. data/lib/openstudio-standards/standards/necb/common/national_carbon_price_sched_feb_2025.json +60 -0
  280. data/lib/openstudio-standards/standards/necb/common/utility_pricing_2025-02-20.csv +92 -0
  281. data/lib/openstudio-standards/utilities/ruleset_check.rb +204 -0
  282. data/lib/openstudio-standards/version.rb +1 -1
  283. data/lib/openstudio-standards/weather/information.rb +1 -1
  284. data/lib/openstudio-standards.rb +32 -12
  285. metadata +78 -80
  286. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.refrigeration.rb +0 -13
  287. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.refrigeration.rb +0 -13
  288. data/lib/openstudio-standards/prototypes/cbes/cbes.refrigeration.rb +0 -13
  289. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.exterior_lights.rb +0 -432
  290. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.Space.rb +0 -11
  291. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.ext_ltg.json +0 -169
  292. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.ref_cases.json +0 -1456
  293. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.ref_lnup.json +0 -562
  294. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.spc_typ.json +0 -20804
  295. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.Space.rb +0 -11
  296. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.ext_ltg.json +0 -169
  297. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.ref_cases.json +0 -1456
  298. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.ref_lnup.json +0 -562
  299. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.ext_ltg.json +0 -169
  300. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.ref_cases.json +0 -1456
  301. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.ref_lnup.json +0 -562
  302. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.ext_ltg.json +0 -169
  303. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.ref_cases.json +0 -1456
  304. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.ref_lnup.json +0 -562
  305. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.ext_ltg.json +0 -169
  306. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.ref_cases.json +0 -763
  307. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.ref_lnup.json +0 -562
  308. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.ext_ltg.json +0 -169
  309. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.ref_cases.json +0 -763
  310. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.ref_lnup.json +0 -562
  311. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.ext_ltg.json +0 -169
  312. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.ref_cases.json +0 -1456
  313. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.ref_lnup.json +0 -562
  314. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.ext_ltg.json +0 -169
  315. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.ref_cases.json +0 -1456
  316. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.ref_lnup.json +0 -562
  317. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.prm_economizers.json +0 -213
  318. data/lib/openstudio-standards/standards/cbes/cbes.Space.rb +0 -11
  319. data/lib/openstudio-standards/standards/cbes/cbes_t24_2005/cbes_t24_2005.Space.rb +0 -11
  320. data/lib/openstudio-standards/standards/cbes/cbes_t24_2008/cbes_t24_2008.Space.rb +0 -11
  321. data/lib/openstudio-standards/standards/deer/deer.Space.rb +0 -20
  322. data/lib/openstudio-standards/standards/deer/deer_1985/data/deer_1985.ref_cases.json +0 -1456
  323. data/lib/openstudio-standards/standards/deer/deer_1985/data/deer_1985.ref_lnup.json +0 -562
  324. data/lib/openstudio-standards/standards/deer/deer_1996/data/deer_1996.ref_cases.json +0 -1456
  325. data/lib/openstudio-standards/standards/deer/deer_1996/data/deer_1996.ref_lnup.json +0 -562
  326. data/lib/openstudio-standards/standards/deer/deer_2003/data/deer_2003.ref_cases.json +0 -1456
  327. data/lib/openstudio-standards/standards/deer/deer_2003/data/deer_2003.ref_lnup.json +0 -562
  328. data/lib/openstudio-standards/standards/deer/deer_2007/data/deer_2007.ref_cases.json +0 -1456
  329. data/lib/openstudio-standards/standards/deer/deer_2007/data/deer_2007.ref_lnup.json +0 -562
  330. data/lib/openstudio-standards/standards/deer/deer_2011/data/deer_2011.ref_cases.json +0 -1456
  331. data/lib/openstudio-standards/standards/deer/deer_2011/data/deer_2011.ref_lnup.json +0 -562
  332. data/lib/openstudio-standards/standards/deer/deer_2014/data/deer_2014.ref_cases.json +0 -1456
  333. data/lib/openstudio-standards/standards/deer/deer_2014/data/deer_2014.ref_lnup.json +0 -562
  334. data/lib/openstudio-standards/standards/deer/deer_2015/data/deer_2015.ref_cases.json +0 -1456
  335. data/lib/openstudio-standards/standards/deer/deer_2015/data/deer_2015.ref_lnup.json +0 -562
  336. data/lib/openstudio-standards/standards/deer/deer_2017/data/deer_2017.ref_cases.json +0 -1456
  337. data/lib/openstudio-standards/standards/deer/deer_2017/data/deer_2017.ref_lnup.json +0 -562
  338. data/lib/openstudio-standards/standards/deer/deer_2020/data/deer_2020.ref_cases.json +0 -1456
  339. data/lib/openstudio-standards/standards/deer/deer_2020/data/deer_2020.ref_lnup.json +0 -562
  340. data/lib/openstudio-standards/standards/deer/deer_2025/data/deer_2025.ref_cases.json +0 -1456
  341. data/lib/openstudio-standards/standards/deer/deer_2025/data/deer_2025.ref_lnup.json +0 -562
  342. data/lib/openstudio-standards/standards/deer/deer_2030/data/deer_2030.ref_cases.json +0 -1456
  343. data/lib/openstudio-standards/standards/deer/deer_2030/data/deer_2030.ref_lnup.json +0 -562
  344. data/lib/openstudio-standards/standards/deer/deer_2035/data/deer_2035.ref_cases.json +0 -1456
  345. data/lib/openstudio-standards/standards/deer/deer_2035/data/deer_2035.ref_lnup.json +0 -562
  346. data/lib/openstudio-standards/standards/deer/deer_2040/data/deer_2040.ref_cases.json +0 -1456
  347. data/lib/openstudio-standards/standards/deer/deer_2040/data/deer_2040.ref_lnup.json +0 -562
  348. data/lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.ref_cases.json +0 -1456
  349. data/lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.ref_lnup.json +0 -562
  350. data/lib/openstudio-standards/standards/deer/deer_2050/data/deer_2050.ref_cases.json +0 -1456
  351. data/lib/openstudio-standards/standards/deer/deer_2050/data/deer_2050.ref_lnup.json +0 -562
  352. data/lib/openstudio-standards/standards/deer/deer_2055/data/deer_2055.ref_cases.json +0 -1456
  353. data/lib/openstudio-standards/standards/deer/deer_2055/data/deer_2055.ref_lnup.json +0 -562
  354. data/lib/openstudio-standards/standards/deer/deer_2060/data/deer_2060.ref_cases.json +0 -1456
  355. data/lib/openstudio-standards/standards/deer/deer_2060/data/deer_2060.ref_lnup.json +0 -562
  356. data/lib/openstudio-standards/standards/deer/deer_2065/data/deer_2065.ref_cases.json +0 -1456
  357. data/lib/openstudio-standards/standards/deer/deer_2065/data/deer_2065.ref_lnup.json +0 -562
  358. data/lib/openstudio-standards/standards/deer/deer_2070/data/deer_2070.ref_cases.json +0 -1456
  359. data/lib/openstudio-standards/standards/deer/deer_2070/data/deer_2070.ref_lnup.json +0 -562
  360. data/lib/openstudio-standards/standards/deer/deer_2075/data/deer_2075.ref_cases.json +0 -1456
  361. data/lib/openstudio-standards/standards/deer/deer_2075/data/deer_2075.ref_lnup.json +0 -562
  362. data/lib/openstudio-standards/standards/deer/deer_pre_1975/data/deer_pre_1975.ref_cases.json +0 -1456
  363. data/lib/openstudio-standards/standards/deer/deer_pre_1975/data/deer_pre_1975.ref_lnup.json +0 -562
@@ -84,28 +84,55 @@ module CoolingTower
84
84
  # per method used in PNNL prototype buildings.
85
85
  # Assumes that the fan brake horsepower is 90%
86
86
  # of the fan nameplate rated motor power.
87
- fan_motor_nameplate_hp = design_water_flow_gpm / min_gpm_per_hp
88
- fan_bhp = 0.9 * fan_motor_nameplate_hp
89
-
90
- # Lookup the minimum motor efficiency
87
+ # Source: Thornton et al. (2011), Achieving the 30% Goal: Energy and Cost Savings Analysis of ASHRAE Standard 90.1-2010, Section 4.5.4
88
+ nominal_hp = design_water_flow_gpm / min_gpm_per_hp
89
+ fan_bhp = 0.9 * nominal_hp
91
90
  fan_motor_eff = 0.85
92
- motors = standards_data['motors']
93
91
 
94
- # Assuming all fan motors are 4-pole Enclosed
95
- search_criteria = {
96
- 'template' => template,
97
- 'number_of_poles' => 4.0,
98
- 'type' => 'Enclosed'
99
- }
92
+ if nominal_hp <= 0.75
93
+ motor_type = motor_type(nominal_hp)
94
+ motor_properties = motor_fractional_hp_efficiencies(nominal_hp, motor_type = motor_type)
95
+ else
96
+ # Lookup the minimum motor efficiency
97
+ motors = standards_data['motors']
98
+
99
+ # Assuming all fan motors are 4-pole Enclosed
100
+ search_criteria = {
101
+ 'template' => template,
102
+ 'number_of_poles' => 4.0,
103
+ 'type' => 'Enclosed'
104
+ }
105
+
106
+ # Use the efficiency largest motor efficiency when BHP is greater than the largest size for which a requirement is provided
107
+ data = model_find_objects(motors, search_criteria)
108
+ if data.empty?
109
+ search_criteria = {
110
+ 'template' => template,
111
+ 'type' => nil
112
+ }
113
+ data = model_find_objects(motors, search_criteria)
114
+ end
115
+ maximum_capacity = model_find_maximum_value(data, 'maximum_capacity')
116
+ if fan_bhp > maximum_capacity
117
+ fan_bhp = maximum_capacity
118
+ end
119
+
120
+ motor_properties = model_find_object(motors, search_criteria, capacity = nil, date = Date.today, area = nil, num_floors = nil, fan_motor_bhp = fan_bhp)
121
+
122
+ if motor_properties.nil?
123
+ # Retry without the date
124
+ motor_properties = model_find_object(motors, search_criteria, capacity = nil, date = nil, area = nil, num_floors = nil, fan_motor_bhp = fan_bhp)
125
+ end
126
+ end
100
127
 
101
- motor_properties = model_find_object(motors, search_criteria, fan_motor_nameplate_hp)
102
128
  if motor_properties.nil?
103
- OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CoolingTower', "For #{cooling_tower.name}, could not find motor properties using search criteria: #{search_criteria}, motor_hp = #{fan_motor_nameplate_hp} hp.")
104
- return false
129
+ OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CoolingTower', "For #{cooling_tower.name}, could not find motor properties using search criteria: #{search_criteria}, motor_hp = #{nominal_hp} hp. Using a default value of #{fan_motor_eff}.")
105
130
  end
106
131
 
107
- fan_motor_eff = motor_properties['nominal_full_load_efficiency']
108
- nominal_hp = motor_properties['maximum_capacity'].to_f.round(1)
132
+ unless motor_properties.nil?
133
+ fan_motor_eff = motor_properties['nominal_full_load_efficiency']
134
+ nominal_hp = motor_properties['maximum_capacity'].to_f.round(1)
135
+ end
109
136
  # Round to nearest whole HP for niceness
110
137
  if nominal_hp >= 2
111
138
  nominal_hp = nominal_hp.round
@@ -116,7 +143,7 @@ module CoolingTower
116
143
  # Convert to W
117
144
  fan_motor_actual_power_w = fan_motor_actual_power_hp * 745.7 # 745.7 W/HP
118
145
 
119
- OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CoolingTower', "For #{cooling_tower.name}, allowed fan motor nameplate hp = #{fan_motor_nameplate_hp.round(1)} hp, fan brake horsepower = #{fan_bhp.round(1)}, and fan motor actual power = #{fan_motor_actual_power_hp.round(1)} hp (#{fan_motor_actual_power_w.round} W) at #{fan_motor_eff} motor efficiency.")
146
+ OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CoolingTower', "For #{cooling_tower.name}, allowed fan motor nameplate hp = #{nominal_hp.round(1)} hp, fan brake horsepower = #{fan_bhp.round(1)}, and fan motor actual power = #{fan_motor_actual_power_hp.round(1)} hp (#{fan_motor_actual_power_w.round} W) at #{fan_motor_eff} motor efficiency.")
120
147
 
121
148
  # Append the efficiency to the name
122
149
  cooling_tower.setName("#{cooling_tower.name} #{min_gpm_per_hp.to_f.round(1)} gpm/hp")
@@ -231,7 +231,7 @@ module Fan
231
231
 
232
232
  # Determines the minimum fan motor efficiency and nominal size for a given motor bhp.
233
233
  # This should be the total brake horsepower with any desired safety factor already included.
234
- # This method picks the next nominal motor catgory larger than the required brake horsepower,
234
+ # This method picks the next nominal motor category larger than the required brake horsepower,
235
235
  # and the efficiency is based on that size.
236
236
  # For example, if the bhp = 6.3, the nominal size will be 7.5HP and the efficiency
237
237
  # for 90.1-2010 will be 91.7% from Table 10.8B.
@@ -243,7 +243,12 @@ module Fan
243
243
  # @return [Array<Double>] minimum motor efficiency (0.0 to 1.0), nominal horsepower
244
244
  def fan_standard_minimum_motor_efficiency_and_size(fan, motor_bhp)
245
245
  fan_motor_eff = 0.85
246
- nominal_hp = motor_bhp
246
+ # Calculate the allowed fan brake horsepower
247
+ # per method used in PNNL prototype buildings.
248
+ # Assumes that the fan brake horsepower is 90%
249
+ # of the fan nameplate rated motor power.
250
+ # Source: Thornton et al. (2011), Achieving the 30% Goal: Energy and Cost Savings Analysis of ASHRAE Standard 90.1-2010, Section 4.5.4
251
+ nominal_hp = motor_bhp * 1.1
247
252
 
248
253
  # Don't attempt to look up motor efficiency
249
254
  # for zero-hp fans, which may occur when there is no
@@ -267,34 +272,40 @@ module Fan
267
272
  # In this case, use the 0.5 HP for the lookup.
268
273
  if fan_small_fan?(fan)
269
274
  nominal_hp = 0.5
270
- else
271
- motor_properties = model_find_object(motors, search_criteria, motor_bhp)
275
+
276
+ # Get the efficiency based on the nominal horsepower
277
+ motor_type = motor_type(nominal_hp)
278
+ motor_properties = motor_fractional_hp_efficiencies(nominal_hp, motor_type = motor_type)
279
+
272
280
  if motor_properties.nil?
273
- OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.Fan', "For #{fan.name}, could not find motor properties using search criteria: #{search_criteria}, motor_bhp = #{motor_bhp} hp.")
281
+ OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.Fan', "For #{fan.name}, could not find nominal motor properties using search criteria: #{search_criteria}, motor_hp = #{nominal_hp} hp.")
274
282
  return [fan_motor_eff, nominal_hp]
275
283
  end
276
-
277
- nominal_hp = motor_properties['maximum_capacity'].to_f.round(1)
278
- # If the biggest fan motor size is hit, use the highest category efficiency
279
- if nominal_hp > 9998.0
280
- OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.Fan', "For #{fan.name}, there is no greater nominal HP. Use the efficiency of the largest motor category.")
281
- nominal_hp = motor_bhp
284
+ else
285
+ # Use the efficiency largest motor efficiency when BHP is greater than the largest size for which a requirement is provided
286
+ data = model_find_objects(motors, search_criteria)
287
+ maximum_capacity = model_find_maximum_value(data, 'maximum_capacity')
288
+ if motor_bhp > maximum_capacity
289
+ motor_bhp = maximum_capacity
282
290
  end
283
291
 
284
- # Round to nearest whole HP for niceness
285
- if nominal_hp >= 2
286
- nominal_hp = nominal_hp.round
292
+ motor_properties = model_find_object(motors, search_criteria, capacity = nil, date = Date.today, area = nil, num_floors = nil, fan_motor_bhp = motor_bhp)
293
+ if motor_properties.nil?
294
+ # Retry without the date
295
+ motor_properties = model_find_object(motors, search_criteria, capacity = nil, date = nil, area = nil, num_floors = nil, fan_motor_bhp = motor_bhp)
296
+ if motor_properties.nil?
297
+ OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.Fan', "For #{fan.name}, could not find motor properties using search criteria: #{search_criteria}, motor_bhp = #{motor_bhp} hp.")
298
+ return [fan_motor_eff, nominal_hp]
299
+ end
287
300
  end
288
301
  end
289
302
 
290
- # Get the efficiency based on the nominal horsepower
291
- # Add 0.01 hp to avoid search errors.
292
- motor_properties = model_find_object(motors, search_criteria, nominal_hp + 0.01)
293
-
294
- if motor_properties.nil?
295
- OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.Fan', "For #{fan.name}, could not find nominal motor properties using search criteria: #{search_criteria}, motor_hp = #{nominal_hp} hp.")
296
- return [fan_motor_eff, nominal_hp]
303
+ nominal_hp = motor_properties['maximum_capacity'].to_f.round(1)
304
+ # Round to nearest whole HP for niceness
305
+ if nominal_hp >= 2
306
+ nominal_hp = nominal_hp.round
297
307
  end
308
+
298
309
  fan_motor_eff = motor_properties['nominal_full_load_efficiency']
299
310
 
300
311
  return [fan_motor_eff, nominal_hp]
@@ -76,27 +76,54 @@ class Standard
76
76
  # per method used in PNNL prototype buildings.
77
77
  # Assumes that the fan brake horsepower is 90%
78
78
  # of the fan nameplate rated motor power.
79
- fan_motor_nameplate_hp = design_water_flow_gpm / min_gpm_per_hp
80
- fan_bhp = 0.9 * fan_motor_nameplate_hp
81
-
82
- # Lookup the minimum motor efficiency
83
- motors = standards_data['motors']
84
-
85
- # Assuming all fan motors are 4-pole Enclosed
86
- search_criteria = {
87
- 'template' => template,
88
- 'number_of_poles' => 4.0,
89
- 'type' => 'Enclosed'
90
- }
79
+ # Source: Thornton et al. (2011), Achieving the 30% Goal: Energy and Cost Savings Analysis of ASHRAE Standard 90.1-2010, Section 4.5.4
80
+ nominal_hp = design_water_flow_gpm / min_gpm_per_hp
81
+ fan_bhp = 0.9 * nominal_hp
82
+ fan_motor_eff = 0.85
83
+
84
+ if nominal_hp <= 0.75
85
+ motor_type = motor_type(nominal_hp)
86
+ motor_properties = motor_fractional_hp_efficiencies(nominal_hp, motor_type = motor_type)
87
+ else
88
+ # Lookup the minimum motor efficiency
89
+ motors = standards_data['motors']
90
+
91
+ # Assuming all fan motors are 4-pole Enclosed
92
+ search_criteria = {
93
+ 'template' => template,
94
+ 'number_of_poles' => 4.0,
95
+ 'type' => 'Enclosed'
96
+ }
97
+
98
+ # Use the efficiency largest motor efficiency when BHP is greater than the largest size for which a requirement is provided
99
+ data = model_find_objects(motors, search_criteria)
100
+ if data.empty?
101
+ search_criteria = {
102
+ 'template' => template,
103
+ 'type' => nil
104
+ }
105
+ data = model_find_objects(motors, search_criteria)
106
+ end
107
+ maximum_capacity = model_find_maximum_value(data, 'maximum_capacity')
108
+ if fan_bhp > maximum_capacity
109
+ fan_bhp = maximum_capacity
110
+ end
111
+
112
+ motor_properties = model_find_object(motors, search_criteria, capacity = nil, date = Date.today, area = nil, num_floors = nil, fan_motor_bhp = fan_bhp)
113
+ if motor_properties.nil?
114
+ # Retry without the date
115
+ motor_properties = model_find_object(motors, search_criteria, capacity = nil, date = nil, area = nil, num_floors = nil, fan_motor_bhp = fan_bhp)
116
+ end
117
+ end
91
118
 
92
- motor_properties = model_find_object(motors, search_criteria, fan_motor_nameplate_hp)
93
119
  if motor_properties.nil?
94
- OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.FluidCooler', "For #{fluid_cooler.name}, could not find motor properties using search criteria: #{search_criteria}, motor_hp = #{motor_hp} hp.")
95
- return false
120
+ OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.FluidCooler', "For #{fluid_cooler.name}, could not find motor properties using search criteria: #{search_criteria}, motor_hp = #{norminal_hp} hp. Using a default value of #{fan_motor_eff}.")
96
121
  end
97
122
 
98
- fan_motor_eff = motor_properties['nominal_full_load_efficiency']
99
- nominal_hp = motor_properties['maximum_capacity'].to_f.round(1)
123
+ unless motor_properties.nil?
124
+ fan_motor_eff = motor_properties['nominal_full_load_efficiency']
125
+ nominal_hp = motor_properties['maximum_capacity'].to_f.round(1)
126
+ end
100
127
  # Round to nearest whole HP for niceness
101
128
  if nominal_hp >= 2
102
129
  nominal_hp = nominal_hp.round
@@ -107,7 +134,7 @@ class Standard
107
134
  # Convert to W
108
135
  fan_motor_actual_power_w = fan_motor_actual_power_hp * 745.7 # 745.7 W/HP
109
136
 
110
- OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.FluidCooler', "For #{fluid_cooler.name}, allowed fan motor nameplate hp = #{fan_motor_nameplate_hp.round(1)} hp, fan brake horsepower = #{fan_bhp.round(1)}, and fan motor actual power = #{fan_motor_actual_power_hp.round(1)} hp (#{fan_motor_actual_power_w.round} W) at #{fan_motor_eff} motor efficiency.")
137
+ OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.FluidCooler', "For #{fluid_cooler.name}, allowed fan motor nameplate hp = #{nominal_hp.round(1)} hp, fan brake horsepower = #{fan_bhp.round(1)}, and fan motor actual power = #{fan_motor_actual_power_hp.round(1)} hp (#{fan_motor_actual_power_w.round} W) at #{fan_motor_eff} motor efficiency.")
111
138
 
112
139
  # Append the efficiency to the name
113
140
  fluid_cooler.setName("#{fluid_cooler.name} #{min_gpm_per_hp.to_f.round(1)} gpm/hp")
@@ -8,21 +8,26 @@ class Standard
8
8
  def heat_exchanger_air_to_air_sensible_and_latent_apply_effectiveness(heat_exchanger_air_to_air_sensible_and_latent)
9
9
  # Assumed to be sensible and latent at all flow
10
10
  full_htg_sens_eff, full_htg_lat_eff, part_htg_sens_eff, part_htg_lat_eff, full_cool_sens_eff, full_cool_lat_eff, part_cool_sens_eff, part_cool_lat_eff = heat_exchanger_air_to_air_sensible_and_latent_minimum_effectiveness(heat_exchanger_air_to_air_sensible_and_latent)
11
-
12
- heat_exchanger_air_to_air_sensible_and_latent.setSensibleEffectivenessat100HeatingAirFlow(full_htg_sens_eff)
13
- heat_exchanger_air_to_air_sensible_and_latent.setLatentEffectivenessat100HeatingAirFlow(full_htg_lat_eff)
14
- heat_exchanger_air_to_air_sensible_and_latent.setSensibleEffectivenessat100CoolingAirFlow(full_cool_sens_eff)
15
- heat_exchanger_air_to_air_sensible_and_latent.setLatentEffectivenessat100CoolingAirFlow(full_cool_lat_eff)
16
11
  if heat_exchanger_air_to_air_sensible_and_latent.model.version < OpenStudio::VersionString.new('3.8.0')
12
+ heat_exchanger_air_to_air_sensible_and_latent.setSensibleEffectivenessat100HeatingAirFlow(full_htg_sens_eff)
13
+ heat_exchanger_air_to_air_sensible_and_latent.setLatentEffectivenessat100HeatingAirFlow(full_htg_lat_eff)
14
+ heat_exchanger_air_to_air_sensible_and_latent.setSensibleEffectivenessat100CoolingAirFlow(full_cool_sens_eff)
15
+ heat_exchanger_air_to_air_sensible_and_latent.setLatentEffectivenessat100CoolingAirFlow(full_cool_lat_eff)
17
16
  heat_exchanger_air_to_air_sensible_and_latent.setSensibleEffectivenessat75HeatingAirFlow(part_htg_sens_eff)
18
17
  heat_exchanger_air_to_air_sensible_and_latent.setLatentEffectivenessat75HeatingAirFlow(part_htg_lat_eff)
19
18
  heat_exchanger_air_to_air_sensible_and_latent.setSensibleEffectivenessat75CoolingAirFlow(part_cool_sens_eff)
20
19
  heat_exchanger_air_to_air_sensible_and_latent.setLatentEffectivenessat75CoolingAirFlow(part_cool_lat_eff)
21
20
  else
22
- heat_exchanger_air_to_air_sensible_and_latent.setSensibleEffectivenessat75HeatingAirFlow(part_htg_sens_eff) unless part_htg_sens_eff.zero?
23
- heat_exchanger_air_to_air_sensible_and_latent.setLatentEffectivenessat75HeatingAirFlow(part_htg_lat_eff) unless part_htg_lat_eff.zero?
24
- heat_exchanger_air_to_air_sensible_and_latent.setSensibleEffectivenessat75CoolingAirFlow(part_cool_sens_eff) unless part_cool_sens_eff.zero?
25
- heat_exchanger_air_to_air_sensible_and_latent.setLatentEffectivenessat75CoolingAirFlow(part_cool_lat_eff) unless part_cool_lat_eff.zero?
21
+ values = Hash.new{|hash, key| hash[key] = Hash.new}
22
+ values['Sensible Heating'][0.75] = part_htg_sens_eff
23
+ values['Sensible Heating'][1.0] = full_htg_sens_eff
24
+ values['Latent Heating'][0.75] = part_htg_lat_eff
25
+ values['Latent Heating'][1.0] = full_htg_lat_eff
26
+ values['Sensible Cooling'][0.75] = part_cool_sens_eff
27
+ values['Sensible Cooling'][1.0] = full_cool_sens_eff
28
+ values['Latent Cooling'][0.75] = part_cool_lat_eff
29
+ values['Latent Cooling'][1.0] = full_cool_lat_eff
30
+ OpenstudioStandards::HVAC.heat_exchanger_air_to_air_set_effectiveness_values(heat_exchanger_air_to_air_sensible_and_latent, defaults: false, values: values)
26
31
  end
27
32
 
28
33
  OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.HeatExchangerSensLat', "For #{heat_exchanger_air_to_air_sensible_and_latent.name}: Set sensible and latent effectiveness.")