  1. checksums.yaml +4 -4
  2. data/data/standards/OpenStudio_Standards.xlsx +0 -0
  3. data/data/standards/OpenStudio_Standards_boilers.json +62 -4
  4. data/data/standards/OpenStudio_Standards_chillers.json +778 -68
  5. data/data/standards/OpenStudio_Standards_construction_sets.json +52 -93
  6. data/data/standards/OpenStudio_Standards_curve_biquadratics.json +36 -36
  7. data/data/standards/OpenStudio_Standards_curve_quadratics.json +3 -3
  8. data/data/standards/OpenStudio_Standards_heat_pumps.json +840 -0
  9. data/data/standards/OpenStudio_Standards_heat_pumps_heating.json +352 -0
  10. data/data/standards/OpenStudio_Standards_heat_rejection.json +48 -0
  11. data/data/standards/OpenStudio_Standards_motors.json +270 -0
  12. data/data/standards/OpenStudio_Standards_space_types.json +10390 -2824
  13. data/data/standards/OpenStudio_Standards_unitary_acs.json +794 -18
  14. data/data/weather/USA_CO_Boulder-Broomfield-Jefferson.County.AP.724699_TMY3.ddy +538 -0
  15. data/data/weather/USA_CO_Boulder-Broomfield-Jefferson.County.AP.724699_TMY3.epw +8768 -0
  16. data/data/weather/USA_CO_Boulder-Broomfield-Jefferson.County.AP.724699_TMY3.stat +493 -0
  17. data/data/weather/USA_CO_Denver.Intl.AP.725650_TMY3.ddy +536 -0
  18. data/data/weather/USA_CO_Denver.Intl.AP.725650_TMY3.epw +8768 -0
  19. data/data/weather/USA_CO_Denver.Intl.AP.725650_TMY3.stat +554 -0
  20. data/data/weather/USA_CO_Fort.Collins.AWOS.724769_TMY3.ddy +536 -0
  21. data/data/weather/USA_CO_Fort.Collins.AWOS.724769_TMY3.epw +8768 -0
  22. data/data/weather/USA_CO_Fort.Collins.AWOS.724769_TMY3.stat +554 -0
  23. data/data/weather/envelope_info.csv +6 -0
  24. data/lib/openstudio-standards.rb +10 -11
  25. data/lib/openstudio-standards/btap/compliance.rb +251 -969
  26. data/lib/openstudio-standards/btap/envelope.rb +1 -1
  27. data/lib/openstudio-standards/btap/fileio.rb +37 -5
  28. data/lib/openstudio-standards/btap/geometry.rb +27 -17
  29. data/lib/openstudio-standards/btap/hvac.rb +80 -27
  30. data/lib/openstudio-standards/hvac_sizing/{HVACSizing.CoilHeatingDXMultiSpeed.rb → Siz.CoilHeatingDXMultiSpeed.rb} +0 -0
  31. data/lib/openstudio-standards/hvac_sizing/Siz.ControllerOutdoorAir.rb +30 -4
  32. data/lib/openstudio-standards/hvac_sizing/Siz.CoolingTowerTwoSpeed.rb +61 -5
  33. data/lib/openstudio-standards/hvac_sizing/Siz.CoolingTowerVariableSpeed.rb +37 -7
  34. data/lib/openstudio-standards/hvac_sizing/Siz.DistrictCooling.rb +27 -0
  35. data/lib/openstudio-standards/hvac_sizing/Siz.DistrictHeating.rb +27 -0
  36. data/lib/openstudio-standards/hvac_sizing/Siz.HeaderedPumpsConstantSpeed.rb +55 -0
  37. data/lib/openstudio-standards/hvac_sizing/Siz.HeaderedPumpsVariableSpeed.rb +55 -0
  38. data/lib/openstudio-standards/hvac_sizing/Siz.HeatingCoolingFuels.rb +51 -9
  39. data/lib/openstudio-standards/hvac_sizing/Siz.Model.rb +99 -17
  40. data/lib/openstudio-standards/hvac_sizing/Siz.PumpConstantSpeed.rb +1 -1
  41. data/lib/openstudio-standards/hvac_sizing/Siz.ThermalZone.rb +29 -6
  42. data/lib/openstudio-standards/hvac_sizing/Siz.WaterHeaterMixed.rb +16 -0
  43. data/lib/openstudio-standards/prototypes/Prototype.AirTerminalSingleDuctVAVReheat.rb +43 -48
  44. data/lib/openstudio-standards/prototypes/Prototype.ControllerWaterCoil.rb +5 -9
  45. data/lib/openstudio-standards/prototypes/Prototype.Fan.rb +68 -0
  46. data/lib/openstudio-standards/prototypes/Prototype.FanConstantVolume.rb +39 -43
  47. data/lib/openstudio-standards/prototypes/Prototype.FanOnOff.rb +49 -51
  48. data/lib/openstudio-standards/prototypes/Prototype.FanVariableVolume.rb +55 -61
  49. data/lib/openstudio-standards/prototypes/Prototype.FanZoneExhaust.rb +8 -10
  50. data/lib/openstudio-standards/prototypes/Prototype.HeatExchangerAirToAirSensibleAndLatent.rb +15 -20
  51. data/lib/openstudio-standards/prototypes/Prototype.Model.hvac.rb +330 -322
  52. data/lib/openstudio-standards/prototypes/Prototype.Model.rb +501 -446
  53. data/lib/openstudio-standards/prototypes/Prototype.Model.swh.rb +221 -230
  54. data/lib/openstudio-standards/prototypes/Prototype.add_objects.rb +0 -2
  55. data/lib/openstudio-standards/prototypes/Prototype.full_service_restaurant.rb +130 -137
  56. data/lib/openstudio-standards/prototypes/Prototype.high_rise_apartment.rb +374 -291
  57. data/lib/openstudio-standards/prototypes/Prototype.hospital.rb +146 -193
  58. data/lib/openstudio-standards/prototypes/Prototype.hvac_systems.rb +1315 -1113
  59. data/lib/openstudio-standards/prototypes/Prototype.large_hotel.rb +65 -88
  60. data/lib/openstudio-standards/prototypes/Prototype.large_office.rb +101 -156
  61. data/lib/openstudio-standards/prototypes/Prototype.medium_office.rb +46 -96
  62. data/lib/openstudio-standards/prototypes/Prototype.mid_rise_apartment.rb +113 -123
  63. data/lib/openstudio-standards/prototypes/Prototype.outpatient.rb +356 -345
  64. data/lib/openstudio-standards/prototypes/Prototype.primary_school.rb +48 -103
  65. data/lib/openstudio-standards/prototypes/Prototype.quick_service_restaurant.rb +115 -123
  66. data/lib/openstudio-standards/prototypes/Prototype.retail_standalone.rb +30 -39
  67. data/lib/openstudio-standards/prototypes/Prototype.retail_stripmall.rb +32 -45
  68. data/lib/openstudio-standards/prototypes/Prototype.secondary_school.rb +98 -258
  69. data/lib/openstudio-standards/prototypes/Prototype.small_hotel.rb +429 -474
  70. data/lib/openstudio-standards/prototypes/Prototype.small_office.rb +28 -36
  71. data/lib/openstudio-standards/prototypes/Prototype.strip_model.rb +7 -7
  72. data/lib/openstudio-standards/prototypes/Prototype.utilities.rb +172 -146
  73. data/lib/openstudio-standards/prototypes/Prototype.warehouse.rb +46 -53
  74. data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +885 -707
  75. data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctParallelPIUReheat.rb +48 -57
  76. data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +24 -31
  77. data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +80 -93
  78. data/lib/openstudio-standards/standards/Standards.BuildingStory.rb +69 -0
  79. data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +60 -72
  80. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +104 -108
  81. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +190 -198
  82. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +134 -146
  83. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +56 -60
  84. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +151 -161
  85. data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +30 -34
  86. data/lib/openstudio-standards/standards/Standards.Construction.rb +116 -132
  87. data/lib/openstudio-standards/standards/Standards.CoolingTower.rb +138 -0
  88. data/lib/openstudio-standards/standards/Standards.CoolingTowerSingleSpeed.rb +11 -0
  89. data/lib/openstudio-standards/standards/Standards.CoolingTowerTwoSpeed.rb +11 -0
  90. data/lib/openstudio-standards/standards/Standards.CoolingTowerVariableSpeed.rb +16 -0
  91. data/lib/openstudio-standards/standards/Standards.Fan.rb +190 -236
  92. data/lib/openstudio-standards/standards/Standards.FanConstantVolume.rb +0 -2
  93. data/lib/openstudio-standards/standards/Standards.FanOnOff.rb +0 -2
  94. data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +168 -14
  95. data/lib/openstudio-standards/standards/Standards.FanZoneExhaust.rb +0 -2
  96. data/lib/openstudio-standards/standards/Standards.HeaderedPumpsConstantSpeed.rb +33 -0
  97. data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +83 -0
  98. data/lib/openstudio-standards/standards/Standards.HeatExchangerSensLat.rb +22 -0
  99. data/lib/openstudio-standards/standards/Standards.Model.rb +2385 -1622
  100. data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +83 -35
  101. data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +805 -395
  102. data/lib/openstudio-standards/standards/Standards.Pump.rb +139 -119
  103. data/lib/openstudio-standards/standards/Standards.PumpConstantSpeed.rb +0 -2
  104. data/lib/openstudio-standards/standards/Standards.PumpVariableSpeed.rb +16 -15
  105. data/lib/openstudio-standards/standards/Standards.ScheduleCompact.rb +35 -0
  106. data/lib/openstudio-standards/standards/Standards.ScheduleConstant.rb +7 -13
  107. data/lib/openstudio-standards/standards/Standards.ScheduleRuleset.rb +144 -59
  108. data/lib/openstudio-standards/standards/Standards.Space.rb +1509 -1326
  109. data/lib/openstudio-standards/standards/Standards.SpaceType.rb +254 -262
  110. data/lib/openstudio-standards/standards/Standards.SubSurface.rb +105 -105
  111. data/lib/openstudio-standards/standards/Standards.Surface.rb +27 -31
  112. data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +882 -157
  113. data/lib/openstudio-standards/standards/Standards.WaterHeaterMixed.rb +179 -69
  114. data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +75 -0
  115. data/lib/openstudio-standards/utilities/logging.rb +31 -38
  116. data/lib/openstudio-standards/utilities/simulation.rb +118 -82
  117. data/lib/openstudio-standards/version.rb +1 -1
  118. data/lib/openstudio-standards/weather/Weather.Model.rb +382 -390
  119. data/lib/openstudio-standards/weather/Weather.stat_file.rb +159 -78
  120. metadata +59 -6
@@ -1,32 +1,29 @@
1
1
 
2
2
  # Reopen the OpenStudio class to add methods to apply standards to this object
3
3
  class OpenStudio::Model::CoilCoolingDXTwoSpeed
4
-
5
4
  # Finds the search criteria
6
5
  #
7
6
  # @param template [String] valid choices: 'DOE Ref Pre-1980', 'DOE Ref 1980-2004', '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013'
8
7
  # @return [hash] has for search criteria to be used for find object
9
8
  def find_search_criteria(template)
10
-
11
9
  # Define the criteria to find the chiller properties
12
10
  # in the hvac standards data set.
13
11
  search_criteria = {}
14
12
  search_criteria['template'] = template
15
- cooling_type = self.condenserType
13
+ cooling_type = condenserType
16
14
  search_criteria['cooling_type'] = cooling_type
17
15
 
18
-
19
16
  # Determine the heating type if unitary or zone hvac
20
17
  heat_pump = false
21
18
  heating_type = nil
22
- if self.airLoopHVAC.empty?
23
- if self.containingHVACComponent.is_initialized
19
+ if airLoopHVAC.empty?
20
+ if containingHVACComponent.is_initialized
24
21
  containing_comp = containingHVACComponent.get
25
22
  if containing_comp.to_AirLoopHVACUnitaryHeatPumpAirToAir.is_initialized
26
23
  heat_pump = true
27
24
  heating_type = 'Electric Resistance or None'
28
- end # TODO Add other unitary systems
29
- elsif self.containingZoneHVACComponent.is_initialized
25
+ end # TODO: Add other unitary systems
26
+ elsif containingZoneHVACComponent.is_initialized
30
27
  containing_comp = containingZoneHVACComponent.get
31
28
  if containing_comp.to_ZoneHVACPackagedTerminalAirConditioner.is_initialized
32
29
  htg_coil = containing_comp.to_ZoneHVACPackagedTerminalAirConditioner.get.heatingCoil
@@ -35,30 +32,30 @@ class OpenStudio::Model::CoilCoolingDXTwoSpeed
35
32
  elsif htg_coil.to_CoilHeatingWater.is_initialized || htg_coil.to_CoilHeatingGas.is_initialized
36
33
  heating_type = 'All Other'
37
34
  end
38
- end # TODO Add other zone hvac systems
35
+ end # TODO: Add other zone hvac systems
39
36
  end
40
37
  end
41
38
 
42
39
  # Determine the heating type if on an airloop
43
- if self.airLoopHVAC.is_initialized
44
- air_loop = self.airLoopHVAC.get
45
- if air_loop.supplyComponents('Coil:Heating:Electric'.to_IddObjectType).size > 0
46
- heating_type = 'Electric Resistance or None'
47
- elsif air_loop.supplyComponents('Coil:Heating:Gas'.to_IddObjectType).size > 0
48
- heating_type = 'All Other'
49
- elsif air_loop.supplyComponents('Coil:Heating:Water'.to_IddObjectType).size > 0
50
- heating_type = 'All Other'
51
- elsif air_loop.supplyComponents('Coil:Heating:DX:SingleSpeed'.to_IddObjectType).size > 0
52
- heating_type = 'All Other'
53
- elsif air_loop.supplyComponents('Coil:Heating:Gas:MultiStage'.to_IddObjectType).size > 0
54
- heating_type = 'All Other'
55
- elsif air_loop.supplyComponents('Coil:Heating:Desuperheater'.to_IddObjectType).size > 0
56
- heating_type = 'All Other'
57
- elsif air_loop.supplyComponents('Coil:Heating:WaterToAirHeatPump:EquationFit'.to_IddObjectType).size > 0
58
- heating_type = 'All Other'
59
- else
60
- heating_type = 'Electric Resistance or None'
61
- end
40
+ if airLoopHVAC.is_initialized
41
+ air_loop = airLoopHVAC.get
42
+ heating_type = if !air_loop.supplyComponents('OS:Coil:Heating:Electric'.to_IddObjectType).empty?
43
+ 'Electric Resistance or None'
44
+ elsif !air_loop.supplyComponents('OS:Coil:Heating:Gas'.to_IddObjectType).empty?
45
+ 'All Other'
46
+ elsif !air_loop.supplyComponents('OS:Coil:Heating:Water'.to_IddObjectType).empty?
47
+ 'All Other'
48
+ elsif !air_loop.supplyComponents('OS:Coil:Heating:DX:SingleSpeed'.to_IddObjectType).empty?
49
+ 'All Other'
50
+ elsif !air_loop.supplyComponents('OS:Coil:Heating:Gas:MultiStage'.to_IddObjectType).empty?
51
+ 'All Other'
52
+ elsif !air_loop.supplyComponents('OS:Coil:Heating:Desuperheater'.to_IddObjectType).empty?
53
+ 'All Other'
54
+ elsif !air_loop.supplyComponents('OS:Coil:Heating:WaterToAirHeatPump:EquationFit'.to_IddObjectType).empty?
55
+ 'All Other'
56
+ else
57
+ 'Electric Resistance or None'
58
+ end
62
59
  end
63
60
 
64
61
  # Add the heating type to the search criteria
@@ -66,37 +63,34 @@ class OpenStudio::Model::CoilCoolingDXTwoSpeed
66
63
  search_criteria['heating_type'] = heating_type
67
64
  end
68
65
 
69
- # TODO Standards - add split system vs single package to model
66
+ # TODO: Standards - add split system vs single package to model
70
67
  # For now, assume single package
71
68
  subcategory = 'Single Package'
72
69
  search_criteria['subcategory'] = subcategory
73
70
 
74
71
  return search_criteria
75
-
76
72
  end
77
73
 
78
74
  # Finds capacity in tons
79
75
  #
80
76
  # @return [Double] capacity in tons to be used for find object
81
- def find_capacity()
82
-
77
+ def find_capacity
83
78
  # Get the coil capacity
84
79
  capacity_w = nil
85
- if self.ratedHighSpeedTotalCoolingCapacity.is_initialized
86
- capacity_w = self.ratedHighSpeedTotalCoolingCapacity.get
87
- elsif self.autosizedRatedHighSpeedTotalCoolingCapacity.is_initialized
88
- capacity_w = self.autosizedRatedHighSpeedTotalCoolingCapacity.get
80
+ if ratedHighSpeedTotalCoolingCapacity.is_initialized
81
+ capacity_w = ratedHighSpeedTotalCoolingCapacity.get
82
+ elsif autosizedRatedHighSpeedTotalCoolingCapacity.is_initialized
83
+ capacity_w = autosizedRatedHighSpeedTotalCoolingCapacity.get
89
84
  else
90
- #OpenStudio::logFree(OpenStudio::Warn, 'openstudio.standards.CoilCoolingDXSingleSpeed', "For #{self.name} capacity is not available, cannot apply efficiency standard.")
85
+ # OpenStudio::logFree(OpenStudio::Warn, 'openstudio.standards.CoilCoolingDXSingleSpeed', "For #{self.name} capacity is not available, cannot apply efficiency standard.")
91
86
  successfully_set_all_properties = false
92
87
  return successfully_set_all_properties
93
88
  end
94
89
 
95
90
  # Convert capacity to Btu/hr
96
- capacity_btu_per_hr = OpenStudio.convert(capacity_w, "W", "Btu/hr").get
91
+ capacity_btu_per_hr = OpenStudio.convert(capacity_w, 'W', 'Btu/hr').get
97
92
 
98
93
  return capacity_btu_per_hr
99
-
100
94
  end
101
95
 
102
96
  # Finds lookup object in standards and return efficiency
@@ -104,246 +98,240 @@ class OpenStudio::Model::CoilCoolingDXTwoSpeed
104
98
  # @param template [String] valid choices: 'DOE Ref Pre-1980', 'DOE Ref 1980-2004', '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013'
105
99
  # @param standards [Hash] the OpenStudio_Standards spreadsheet in hash format
106
100
  # @return [Double] full load efficiency (COP)
107
- def standard_minimum_cop(template,standards)
108
-
101
+ def standard_minimum_cop(template, standards)
109
102
  # find ac properties
110
- search_criteria = self.find_search_criteria(template)
111
- cooling_type = search_criteria["cooling_type"]
112
- heating_type = search_criteria["heating_type"]
113
- subcategory = search_criteria["subcategory"]
114
- capacity_btu_per_hr = self.find_capacity
115
- capacity_kbtu_per_hr = OpenStudio.convert(capacity_btu_per_hr, "Btu/hr", "kBtu/hr").get
103
+ search_criteria = find_search_criteria(template)
104
+ cooling_type = search_criteria['cooling_type']
105
+ heating_type = search_criteria['heating_type']
106
+ subcategory = search_criteria['subcategory']
107
+ capacity_btu_per_hr = find_capacity
108
+ capacity_kbtu_per_hr = OpenStudio.convert(capacity_btu_per_hr, 'Btu/hr', 'kBtu/hr').get
116
109
 
117
- ac_props = self.model.find_object(standards["unitary_acs"], search_criteria, capacity_btu_per_hr)
110
+ ac_props = model.find_object(standards['unitary_acs'], search_criteria, capacity_btu_per_hr, Date.today)
118
111
 
119
112
  # Get the minimum efficiency standards
120
113
  cop = nil
121
114
 
122
115
  # Check to make sure properties were found
123
116
  if ac_props.nil?
124
- OpenStudio::logFree(OpenStudio::Warn, 'openstudio.standards.CoilCoolingDXTwoSpeed', "For #{self.name}, cannot find efficiency info, cannot apply efficiency standard.")
117
+ OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.CoilCoolingDXTwoSpeed', "For #{name}, cannot find efficiency info, cannot apply efficiency standard.")
125
118
  return cop # value of nil
126
119
  end
127
120
 
128
121
  # If specified as SEER
129
122
  unless ac_props['minimum_seasonal_energy_efficiency_ratio'].nil?
130
123
  min_seer = ac_props['minimum_seasonal_energy_efficiency_ratio']
131
- cop = seer_to_cop(min_seer)
132
- OpenStudio::logFree(OpenStudio::Info, 'openstudio.standards.CoilCoolingDXTwoSpeed', "For #{template}: #{self.name}: #{cooling_type} #{heating_type} #{subcategory} Capacity = #{capacity_kbtu_per_hr.round}kBtu/hr; SEER = #{min_seer}")
124
+ cop = seer_to_cop_cooling_no_fan(min_seer)
125
+ OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CoilCoolingDXTwoSpeed', "For #{template}: #{name}: #{cooling_type} #{heating_type} #{subcategory} Capacity = #{capacity_kbtu_per_hr.round}kBtu/hr; SEER = #{min_seer}")
133
126
  end
134
127
 
135
128
  # If specified as EER
136
129
  unless ac_props['minimum_energy_efficiency_ratio'].nil?
137
130
  min_eer = ac_props['minimum_energy_efficiency_ratio']
138
- cop = eer_to_cop(min_eer)
139
- OpenStudio::logFree(OpenStudio::Info, 'openstudio.standards.CoilCoolingDXTwoSpeed', "For #{template}: #{self.name}: #{cooling_type} #{heating_type} #{subcategory} Capacity = #{capacity_kbtu_per_hr.round}kBtu/hr; EER = #{min_eer}")
131
+ cop = eer_to_cop(min_eer, OpenStudio.convert(capacity_kbtu_per_hr, 'kBtu/hr', 'W').get)
132
+ OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CoilCoolingDXTwoSpeed', "For #{template}: #{name}: #{cooling_type} #{heating_type} #{subcategory} Capacity = #{capacity_kbtu_per_hr.round}kBtu/hr; EER = #{min_eer}")
140
133
  end
141
134
 
142
135
  # if specified as SEER (heat pump)
143
136
  unless ac_props['minimum_seasonal_efficiency'].nil?
144
137
  min_seer = ac_props['minimum_seasonal_efficiency']
145
- cop = seer_to_cop(min_seer)
146
- OpenStudio::logFree(OpenStudio::Info, 'openstudio.standards.CoilCoolingDXSingleSpeed', "For #{template}: #{self.name}: #{cooling_type} #{heating_type} #{subcategory} Capacity = #{capacity_kbtu_per_hr.round}kBtu/hr; SEER = #{min_seer}")
138
+ cop = seer_to_cop_cooling_no_fan(min_seer)
139
+ OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CoilCoolingDXSingleSpeed', "For #{template}: #{name}: #{cooling_type} #{heating_type} #{subcategory} Capacity = #{capacity_kbtu_per_hr.round}kBtu/hr; SEER = #{min_seer}")
147
140
  end
148
141
 
149
142
  # If specified as EER (heat pump)
150
143
  unless ac_props['minimum_full_load_efficiency'].nil?
151
144
  min_eer = ac_props['minimum_full_load_efficiency']
152
- cop = eer_to_cop(min_eer)
153
- OpenStudio::logFree(OpenStudio::Info, 'openstudio.standards.CoilCoolingDXSingleSpeed', "For #{template}: #{self.name}: #{cooling_type} #{heating_type} #{subcategory} Capacity = #{capacity_kbtu_per_hr.round}kBtu/hr; EER = #{min_eer}")
145
+ cop = eer_to_cop(min_eer, OpenStudio.convert(capacity_kbtu_per_hr, 'kBtu/hr', 'W').get)
146
+ OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CoilCoolingDXSingleSpeed', "For #{template}: #{name}: #{cooling_type} #{heating_type} #{subcategory} Capacity = #{capacity_kbtu_per_hr.round}kBtu/hr; EER = #{min_eer}")
154
147
  end
155
148
 
156
149
  return cop
157
-
158
150
  end
159
151
 
160
152
  # Applies the standard efficiency ratings and typical performance curves to this object.
161
- #
153
+ #
162
154
  # @param template [String] valid choices: 'DOE Ref Pre-1980', 'DOE Ref 1980-2004', '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013'
163
155
  # @param standards [Hash] the OpenStudio_Standards spreadsheet in hash format
164
156
  # @return [Bool] true if successful, false if not
165
- def setStandardEfficiencyAndCurves(template)
157
+ def apply_efficiency_and_curves(template)
158
+ successfully_set_all_properties = true
166
159
 
167
- successfully_set_all_properties = true
168
-
169
160
  unitary_acs = $os_standards['unitary_acs']
170
-
161
+
171
162
  # Define the criteria to find the chiller properties
172
163
  # in the hvac standards data set.
173
164
  search_criteria = {}
174
165
  search_criteria['template'] = template
175
- cooling_type = self.condenserType
166
+ cooling_type = condenserType
176
167
  search_criteria['cooling_type'] = cooling_type
177
-
178
168
 
179
169
  # Determine the heating type if unitary or zone hvac
180
170
  heat_pump = false
181
171
  heating_type = nil
182
- if self.airLoopHVAC.empty?
183
- if self.containingHVACComponent.is_initialized
172
+ if airLoopHVAC.empty?
173
+ if containingHVACComponent.is_initialized
184
174
  containing_comp = containingHVACComponent.get
185
175
  if containing_comp.to_AirLoopHVACUnitaryHeatPumpAirToAir.is_initialized
186
176
  heat_pump = true
187
177
  heating_type = 'Electric Resistance or None'
188
- end # TODO Add other unitary systems
189
- elsif self.containingZoneHVACComponent.is_initialized
178
+ end # TODO: Add other unitary systems
179
+ elsif containingZoneHVACComponent.is_initialized
190
180
  containing_comp = containingZoneHVACComponent.get
191
181
  if containing_comp.to_ZoneHVACPackagedTerminalAirConditioner.is_initialized
192
182
  htg_coil = containing_comp.to_ZoneHVACPackagedTerminalAirConditioner.get.heatingCoil
193
183
  if htg_coil.to_CoilHeatingElectric.is_initialized
194
- heating_type = 'Electric Resistance or None'
184
+ heating_type = 'Electric Resistance or None'
195
185
  elsif htg_coil.to_CoilHeatingWater.is_initialized || htg_coil.to_CoilHeatingGas.is_initialized
196
186
  heating_type = 'All Other'
197
- end
198
- end # TODO Add other zone hvac systems
187
+ end
188
+ end # TODO: Add other zone hvac systems
199
189
  end
200
- end
201
-
190
+ end
191
+
202
192
  # Determine the heating type if on an airloop
203
- if self.airLoopHVAC.is_initialized
204
- air_loop = self.airLoopHVAC.get
205
- if air_loop.supplyComponents('Coil:Heating:Electric'.to_IddObjectType).size > 0
206
- heating_type = 'Electric Resistance or None'
207
- elsif air_loop.supplyComponents('Coil:Heating:Gas'.to_IddObjectType).size > 0
208
- heating_type = 'All Other'
209
- elsif air_loop.supplyComponents('Coil:Heating:Water'.to_IddObjectType).size > 0
210
- heating_type = 'All Other'
211
- elsif air_loop.supplyComponents('Coil:Heating:DX:SingleSpeed'.to_IddObjectType).size > 0
212
- heating_type = 'All Other'
213
- elsif air_loop.supplyComponents('Coil:Heating:Gas:MultiStage'.to_IddObjectType).size > 0
214
- heating_type = 'All Other'
215
- elsif air_loop.supplyComponents('Coil:Heating:Desuperheater'.to_IddObjectType).size > 0
216
- heating_type = 'All Other'
217
- elsif air_loop.supplyComponents('Coil:Heating:WaterToAirHeatPump:EquationFit'.to_IddObjectType).size > 0
218
- heating_type = 'All Other'
219
- else
220
- heating_type = 'Electric Resistance or None'
221
- end
193
+ if airLoopHVAC.is_initialized
194
+ air_loop = airLoopHVAC.get
195
+ heating_type = if !air_loop.supplyComponents('OS:Coil:Heating:Electric'.to_IddObjectType).empty?
196
+ 'Electric Resistance or None'
197
+ elsif !air_loop.supplyComponents('OS:Coil:Heating:Gas'.to_IddObjectType).empty?
198
+ 'All Other'
199
+ elsif !air_loop.supplyComponents('OS:Coil:Heating:Water'.to_IddObjectType).empty?
200
+ 'All Other'
201
+ elsif !air_loop.supplyComponents('OS:Coil:Heating:DX:SingleSpeed'.to_IddObjectType).empty?
202
+ 'All Other'
203
+ elsif !air_loop.supplyComponents('OS:Coil:Heating:Gas:MultiStage'.to_IddObjectType).empty?
204
+ 'All Other'
205
+ elsif !air_loop.supplyComponents('OS:Coil:Heating:Desuperheater'.to_IddObjectType).empty?
206
+ 'All Other'
207
+ elsif !air_loop.supplyComponents('OS:Coil:Heating:WaterToAirHeatPump:EquationFit'.to_IddObjectType).empty?
208
+ 'All Other'
209
+ else
210
+ 'Electric Resistance or None'
211
+ end
222
212
  end
223
-
213
+
224
214
  # Add the heating type to the search criteria
225
215
  unless heating_type.nil?
226
216
  search_criteria['heating_type'] = heating_type
227
217
  end
228
-
229
- # TODO Standards - add split system vs single package to model
218
+
219
+ # TODO: Standards - add split system vs single package to model
230
220
  # For now, assume single package
231
221
  subcategory = 'Single Package'
232
222
  search_criteria['subcategory'] = subcategory
233
223
 
234
224
  # Get the coil capacity
235
225
  capacity_w = nil
236
- if self.ratedHighSpeedTotalCoolingCapacity.is_initialized
237
- capacity_w = self.ratedHighSpeedTotalCoolingCapacity.get
238
- elsif self.autosizedRatedHighSpeedTotalCoolingCapacity.is_initialized
239
- capacity_w = self.autosizedRatedHighSpeedTotalCoolingCapacity.get
226
+ if ratedHighSpeedTotalCoolingCapacity.is_initialized
227
+ capacity_w = ratedHighSpeedTotalCoolingCapacity.get
228
+ elsif autosizedRatedHighSpeedTotalCoolingCapacity.is_initialized
229
+ capacity_w = autosizedRatedHighSpeedTotalCoolingCapacity.get
240
230
  else
241
- #OpenStudio::logFree(OpenStudio::Warn, 'openstudio.standards.CoilCoolingDXSingleSpeed', "For #{self.name} capacity is not available, cannot apply efficiency standard.")
231
+ # OpenStudio::logFree(OpenStudio::Warn, 'openstudio.standards.CoilCoolingDXSingleSpeed', "For #{self.name} capacity is not available, cannot apply efficiency standard.")
242
232
  successfully_set_all_properties = false
243
233
  return successfully_set_all_properties
244
- end
245
-
234
+ end
235
+
246
236
  # Convert capacity to Btu/hr
247
- capacity_btu_per_hr = OpenStudio.convert(capacity_w, "W", "Btu/hr").get
248
- capacity_kbtu_per_hr = OpenStudio.convert(capacity_w, "W", "kBtu/hr").get
249
-
250
- ac_props = self.model.find_object(unitary_acs, search_criteria, capacity_btu_per_hr)
237
+ capacity_btu_per_hr = OpenStudio.convert(capacity_w, 'W', 'Btu/hr').get
238
+ capacity_kbtu_per_hr = OpenStudio.convert(capacity_w, 'W', 'kBtu/hr').get
239
+
240
+ ac_props = model.find_object(unitary_acs, search_criteria, capacity_btu_per_hr, Date.today)
251
241
 
252
242
  # Check to make sure properties were found
253
243
  if ac_props.nil?
254
- OpenStudio::logFree(OpenStudio::Warn, 'openstudio.standards.CoilCoolingDXTwoSpeed', "For #{self.name}, cannot find efficiency info, cannot apply efficiency standard.")
244
+ OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.CoilCoolingDXTwoSpeed', "For #{name}, cannot find efficiency info, cannot apply efficiency standard.")
255
245
  successfully_set_all_properties = false
256
246
  return successfully_set_all_properties
257
247
  end
258
-
248
+
259
249
  # Make the total COOL-CAP-FT curve
260
- tot_cool_cap_ft = self.model.add_curve(ac_props["cool_cap_ft"])
250
+ tot_cool_cap_ft = model.add_curve(ac_props['cool_cap_ft'])
261
251
  if tot_cool_cap_ft
262
- self.setTotalCoolingCapacityFunctionOfTemperatureCurve(tot_cool_cap_ft)
252
+ setTotalCoolingCapacityFunctionOfTemperatureCurve(tot_cool_cap_ft)
263
253
  else
264
- OpenStudio::logFree(OpenStudio::Warn, 'openstudio.standards.CoilCoolingDXTwoSpeed', "For #{self.name}, cannot find cool_cap_ft curve, will not be set.")
254
+ OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.CoilCoolingDXTwoSpeed', "For #{name}, cannot find cool_cap_ft curve, will not be set.")
265
255
  successfully_set_all_properties = false
266
256
  end
267
257
 
268
258
  # Make the total COOL-CAP-FFLOW curve
269
- tot_cool_cap_fflow = self.model.add_curve(ac_props["cool_cap_fflow"])
259
+ tot_cool_cap_fflow = model.add_curve(ac_props['cool_cap_fflow'])
270
260
  if tot_cool_cap_fflow
271
- self.setTotalCoolingCapacityFunctionOfFlowFractionCurve(tot_cool_cap_fflow)
261
+ setTotalCoolingCapacityFunctionOfFlowFractionCurve(tot_cool_cap_fflow)
272
262
  else
273
- OpenStudio::logFree(OpenStudio::Warn, 'openstudio.standards.CoilCoolingDXTwoSpeed', "For #{self.name}, cannot find cool_cap_fflow curve, will not be set.")
263
+ OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.CoilCoolingDXTwoSpeed', "For #{name}, cannot find cool_cap_fflow curve, will not be set.")
274
264
  successfully_set_all_properties = false
275
265
  end
276
-
266
+
277
267
  # Make the COOL-EIR-FT curve
278
- cool_eir_ft = self.model.add_curve(ac_props["cool_eir_ft"])
268
+ cool_eir_ft = model.add_curve(ac_props['cool_eir_ft'])
279
269
  if cool_eir_ft
280
- self.setEnergyInputRatioFunctionOfTemperatureCurve(cool_eir_ft)
270
+ setEnergyInputRatioFunctionOfTemperatureCurve(cool_eir_ft)
281
271
  else
282
- OpenStudio::logFree(OpenStudio::Warn, 'openstudio.standards.CoilCoolingDXTwoSpeed', "For #{self.name}, cannot find cool_eir_ft curve, will not be set.")
272
+ OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.CoilCoolingDXTwoSpeed', "For #{name}, cannot find cool_eir_ft curve, will not be set.")
283
273
  successfully_set_all_properties = false
284
274
  end
285
275
 
286
276
  # Make the COOL-EIR-FFLOW curve
287
- cool_eir_fflow = self.model.add_curve(ac_props["cool_eir_fflow"])
277
+ cool_eir_fflow = model.add_curve(ac_props['cool_eir_fflow'])
288
278
  if cool_eir_fflow
289
- self.setEnergyInputRatioFunctionOfFlowFractionCurve(cool_eir_fflow)
279
+ setEnergyInputRatioFunctionOfFlowFractionCurve(cool_eir_fflow)
290
280
  else
291
- OpenStudio::logFree(OpenStudio::Warn, 'openstudio.standards.CoilCoolingDXTwoSpeed', "For #{self.name}, cannot find cool_eir_fflow curve, will not be set.")
281
+ OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.CoilCoolingDXTwoSpeed', "For #{name}, cannot find cool_eir_fflow curve, will not be set.")
292
282
  successfully_set_all_properties = false
293
283
  end
294
-
284
+
295
285
  # Make the COOL-PLF-FPLR curve
296
- cool_plf_fplr = self.model.add_curve(ac_props["cool_plf_fplr"])
286
+ cool_plf_fplr = model.add_curve(ac_props['cool_plf_fplr'])
297
287
  if cool_plf_fplr
298
- self.setPartLoadFractionCorrelationCurve(cool_plf_fplr)
288
+ setPartLoadFractionCorrelationCurve(cool_plf_fplr)
299
289
  else
300
- OpenStudio::logFree(OpenStudio::Warn, 'openstudio.standards.CoilCoolingDXTwoSpeed', "For #{self.name}, cannot find cool_plf_fplr curve, will not be set.")
290
+ OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.CoilCoolingDXTwoSpeed', "For #{name}, cannot find cool_plf_fplr curve, will not be set.")
301
291
  successfully_set_all_properties = false
302
292
  end
303
-
293
+
304
294
  # Make the low speed COOL-CAP-FT curve
305
- low_speed_cool_cap_ft = self.model.add_curve(ac_props["cool_cap_ft"])
295
+ low_speed_cool_cap_ft = model.add_curve(ac_props['cool_cap_ft'])
306
296
  if low_speed_cool_cap_ft
307
- self.setLowSpeedTotalCoolingCapacityFunctionOfTemperatureCurve(low_speed_cool_cap_ft)
297
+ setLowSpeedTotalCoolingCapacityFunctionOfTemperatureCurve(low_speed_cool_cap_ft)
308
298
  else
309
- OpenStudio::logFree(OpenStudio::Warn, 'openstudio.standards.CoilCoolingDXTwoSpeed', "For #{self.name}, cannot find cool_cap_ft curve, will not be set.")
299
+ OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.CoilCoolingDXTwoSpeed', "For #{name}, cannot find cool_cap_ft curve, will not be set.")
310
300
  successfully_set_all_properties = false
311
301
  end
312
302
 
313
303
  # Make the low speed COOL-EIR-FT curve
314
- low_speed_cool_eir_ft = self.model.add_curve(ac_props["cool_eir_ft"])
304
+ low_speed_cool_eir_ft = model.add_curve(ac_props['cool_eir_ft'])
315
305
  if low_speed_cool_eir_ft
316
- self.setLowSpeedEnergyInputRatioFunctionOfTemperatureCurve(low_speed_cool_eir_ft)
306
+ setLowSpeedEnergyInputRatioFunctionOfTemperatureCurve(low_speed_cool_eir_ft)
317
307
  else
318
- OpenStudio::logFree(OpenStudio::Warn, 'openstudio.standards.CoilCoolingDXTwoSpeed', "For #{self.name}, cannot find cool_eir_ft curve, will not be set.")
308
+ OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.CoilCoolingDXTwoSpeed', "For #{name}, cannot find cool_eir_ft curve, will not be set.")
319
309
  successfully_set_all_properties = false
320
310
  end
321
311
 
322
312
  # Get the minimum efficiency standards
323
313
  cop = nil
324
-
314
+
325
315
  # If specified as SEER
326
316
  unless ac_props['minimum_seasonal_energy_efficiency_ratio'].nil?
327
317
  min_seer = ac_props['minimum_seasonal_energy_efficiency_ratio']
328
- cop = seer_to_cop(min_seer)
329
- self.setName("#{self.name} #{capacity_kbtu_per_hr.round}kBtu/hr #{min_seer}SEER")
330
- OpenStudio::logFree(OpenStudio::Info, 'openstudio.standards.CoilCoolingDXTwoSpeed', "For #{template}: #{self.name}: #{cooling_type} #{heating_type} #{subcategory} Capacity = #{capacity_kbtu_per_hr.round}kBtu/hr; SEER = #{min_seer}")
318
+ cop = seer_to_cop_cooling_no_fan(min_seer)
319
+ setName("#{name} #{capacity_kbtu_per_hr.round}kBtu/hr #{min_seer}SEER")
320
+ OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CoilCoolingDXTwoSpeed', "For #{template}: #{name}: #{cooling_type} #{heating_type} #{subcategory} Capacity = #{capacity_kbtu_per_hr.round}kBtu/hr; SEER = #{min_seer}")
331
321
  end
332
-
322
+
333
323
  # If specified as EER
334
324
  unless ac_props['minimum_energy_efficiency_ratio'].nil?
335
325
  min_eer = ac_props['minimum_energy_efficiency_ratio']
336
- cop = eer_to_cop(min_eer)
337
- self.setName("#{self.name} #{capacity_kbtu_per_hr.round}kBtu/hr #{min_eer}EER")
338
- OpenStudio::logFree(OpenStudio::Info, 'openstudio.standards.CoilCoolingDXTwoSpeed', "For #{template}: #{self.name}: #{cooling_type} #{heating_type} #{subcategory} Capacity = #{capacity_kbtu_per_hr.round}kBtu/hr; EER = #{min_eer}")
326
+ cop = eer_to_cop(min_eer, OpenStudio.convert(capacity_kbtu_per_hr, 'kBtu/hr', 'W').get)
327
+ setName("#{name} #{capacity_kbtu_per_hr.round}kBtu/hr #{min_eer}EER")
328
+ OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CoilCoolingDXTwoSpeed', "For #{template}: #{name}: #{cooling_type} #{heating_type} #{subcategory} Capacity = #{capacity_kbtu_per_hr.round}kBtu/hr; EER = #{min_eer}")
339
329
  end
340
330
 
341
331
  # Set the efficiency values
342
- self.setRatedHighSpeedCOP(cop)
343
- self.setRatedLowSpeedCOP(cop)
344
-
345
- return true
332
+ setRatedHighSpeedCOP(cop)
333
+ setRatedLowSpeedCOP(cop)
346
334
 
335
+ return true
347
336
  end
348
-
349
337
  end