openstudio-geb 0.6.0 → 0.7.0
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- checksums.yaml +4 -4
- data/CHANGELOG.md +4 -1
- data/Gemfile +1 -1
- data/lib/measures/AddElectricVehicleChargingLoad/README.md +16 -0
- data/lib/measures/AddElectricVehicleChargingLoad/measure.xml +64 -32
- data/lib/measures/AdjustThermostatSetpointsByDegreesForPeakHours/README.md +266 -42
- data/lib/measures/AdjustThermostatSetpointsByDegreesForPeakHours/measure.xml +330 -95
- data/lib/measures/GEB Metrics Report/README.md +41 -1
- data/lib/measures/GEB Metrics Report/measure.xml +84 -241
- data/lib/measures/GEB Metrics Report/resources/os_lib_reporting.rb +5 -5
- data/lib/measures/add_ceiling_fan/measure.xml +30 -30
- data/lib/measures/add_chilled_water_storage_tank/README.md +73 -33
- data/lib/measures/add_chilled_water_storage_tank/measure.rb +5 -0
- data/lib/measures/add_chilled_water_storage_tank/measure.xml +23 -23
- data/lib/measures/add_chilled_water_storage_tank/tests/370_medium_office_doas_fan_coil_acc_boiler_3A.osm +31800 -0
- data/lib/measures/add_chilled_water_storage_tank/tests/LargeOffice-90.1-2013-ASHRAE 169-2013-5A.osm +22036 -0
- data/lib/measures/add_exterior_blinds_and_control/measure.xml +28 -28
- data/lib/measures/add_fan_assist_night_ventilation_with_hybrid_control/measure.rb +5 -0
- data/lib/measures/add_fan_assist_night_ventilation_with_hybrid_control/measure.xml +20 -44
- data/lib/measures/add_heat_pump_water_heater/measure.rb +28 -28
- data/lib/measures/add_heat_pump_water_heater/measure.xml +30 -95
- data/lib/measures/add_interior_blinds_and_control/measure.xml +28 -28
- data/lib/measures/add_rooftop_pv_simple/measure.xml +24 -24
- data/lib/measures/apply_dynamic_coating_to_roof_wall/LICENSE.md +13 -1
- data/lib/measures/apply_dynamic_coating_to_roof_wall/measure.rb +5 -0
- data/lib/measures/apply_dynamic_coating_to_roof_wall/measure.xml +20 -14
- data/lib/measures/apply_dynamic_coating_to_roof_wall/tests/SFD_1story_UB_UA_ASHP2_HPWH.osm +13110 -0
- data/lib/measures/apply_dynamic_coating_to_roof_wall/tests/apply_dynamic_coating_to_roof_wall_test.rb +5 -0
- data/lib/measures/average_ventilation_for_peak_hours/measure.xml +20 -20
- data/lib/measures/enable_occupancy_driven_lighting/measure.xml +28 -28
- data/lib/measures/precooling/README.md +137 -17
- data/lib/measures/precooling/measure.xml +172 -44
- data/lib/measures/preheating/README.md +125 -21
- data/lib/measures/preheating/measure.xml +160 -50
- data/lib/measures/reduce_epd_by_percentage_for_peak_hours/README.md +125 -29
- data/lib/measures/reduce_epd_by_percentage_for_peak_hours/measure.xml +178 -70
- data/lib/measures/reduce_lpd_by_percentage_for_peak_hours/README.md +132 -28
- data/lib/measures/reduce_lpd_by_percentage_for_peak_hours/measure.xml +186 -69
- data/lib/openstudio/geb/version.rb +1 -1
- data/openstudio-geb.gemspec +4 -2
- metadata +37 -6
@@ -8,7 +8,7 @@
|
|
8
8
|
This measure adds a chilled water storage tank to a chilled water loop for the purpose of thermal energy storage.
|
9
9
|
|
10
10
|
## Modeler Description
|
11
|
-
This measure adds a chilled water storage tank and links it to an existing chilled water loop.
|
11
|
+
This measure adds a chilled water storage tank and links it to an existing chilled water loop.
|
12
12
|
|
13
13
|
## Measure Type
|
14
14
|
ModelMeasure
|
@@ -18,103 +18,143 @@ ModelMeasure
|
|
18
18
|
|
19
19
|
## Arguments
|
20
20
|
|
21
|
-
|
22
|
-
Thermal storage chilled water tank volume in m3
|
21
|
+
|
22
|
+
### Thermal storage chilled water tank volume in m3
|
23
|
+
|
23
24
|
**Name:** tank_vol,
|
24
25
|
**Type:** Double,
|
25
|
-
**Units:**
|
26
|
+
**Units:** ,
|
26
27
|
**Required:** false,
|
27
28
|
**Model Dependent:** false
|
28
29
|
|
29
|
-
### Energy
|
30
|
-
|
30
|
+
### Select Energy Storage Objective:
|
31
|
+
|
31
32
|
**Name:** objective,
|
32
33
|
**Type:** Choice,
|
33
34
|
**Units:** ,
|
34
35
|
**Required:** true,
|
35
36
|
**Model Dependent:** false
|
36
37
|
|
37
|
-
###
|
38
|
-
|
38
|
+
### Select Primary Loop:
|
39
|
+
Error: No Cooling Loop Found
|
39
40
|
**Name:** selected_primary_loop_name,
|
40
41
|
**Type:** Choice,
|
41
42
|
**Units:** ,
|
43
|
+
**Required:** false,
|
44
|
+
**Model Dependent:** false
|
45
|
+
|
46
|
+
### Primary Loop (charging) Setpoint Temperature degree C:
|
47
|
+
|
48
|
+
**Name:** primary_loop_sp,
|
49
|
+
**Type:** Double,
|
50
|
+
**Units:** ,
|
42
51
|
**Required:** true,
|
43
|
-
**Model Dependent:**
|
52
|
+
**Model Dependent:** false
|
53
|
+
|
54
|
+
### Secondary Loop (discharging) Setpoint Temperature degree C:
|
55
|
+
|
56
|
+
**Name:** secondary_loop_sp,
|
57
|
+
**Type:** Double,
|
58
|
+
**Units:** ,
|
59
|
+
**Required:** true,
|
60
|
+
**Model Dependent:** false
|
61
|
+
|
62
|
+
### Chilled Water Tank Setpoint Temperature degree C:
|
44
63
|
|
45
|
-
### Setpoint temperature
|
46
|
-
Chilled water tank setpoint temperature in degree C
|
47
64
|
**Name:** tank_charge_sp,
|
48
65
|
**Type:** Double,
|
49
|
-
**Units:**
|
66
|
+
**Units:** ,
|
50
67
|
**Required:** true,
|
51
68
|
**Model Dependent:** false
|
52
69
|
|
53
|
-
### Loop
|
54
|
-
|
70
|
+
### Loop Design Temperature Difference degree C:
|
71
|
+
Enter numeric value to adjust selected loop settings.
|
55
72
|
**Name:** primary_delta_t,
|
56
73
|
**Type:** String,
|
57
|
-
**Units:**
|
74
|
+
**Units:** ,
|
58
75
|
**Required:** true,
|
59
76
|
**Model Dependent:** false
|
60
77
|
|
61
|
-
### Secondary
|
62
|
-
|
78
|
+
### Secondary Loop Design Temperature Difference degree C
|
79
|
+
|
63
80
|
**Name:** secondary_delta_t,
|
64
81
|
**Type:** Double,
|
65
|
-
**Units:**
|
82
|
+
**Units:** ,
|
66
83
|
**Required:** true,
|
67
84
|
**Model Dependent:** false
|
68
85
|
|
69
|
-
###
|
70
|
-
|
71
|
-
**Name:**
|
86
|
+
### Start Date for thermal storage
|
87
|
+
In MM-DD format
|
88
|
+
**Name:** thermal_storage_startdate,
|
72
89
|
**Type:** String,
|
73
90
|
**Units:** ,
|
74
|
-
**Required:**
|
91
|
+
**Required:** false,
|
92
|
+
**Model Dependent:** false
|
93
|
+
|
94
|
+
### End Date for thermal storage
|
95
|
+
In MM-DD format
|
96
|
+
**Name:** thermal_storage_enddate,
|
97
|
+
**Type:** String,
|
98
|
+
**Units:** ,
|
99
|
+
**Required:** false,
|
75
100
|
**Model Dependent:** false
|
76
101
|
|
77
|
-
###
|
78
|
-
|
102
|
+
### Enter Starting Time for Chilled Water Tank Discharge:
|
103
|
+
Use 24 hour format (HR:MM)
|
79
104
|
**Name:** discharge_start,
|
80
105
|
**Type:** String,
|
81
106
|
**Units:** ,
|
82
107
|
**Required:** true,
|
83
108
|
**Model Dependent:** false
|
84
109
|
|
85
|
-
###
|
86
|
-
|
110
|
+
### Enter End Time for Chilled Water Tank Discharge:
|
111
|
+
Use 24 hour format (HR:MM)
|
87
112
|
**Name:** discharge_end,
|
88
113
|
**Type:** String,
|
89
114
|
**Units:** ,
|
90
115
|
**Required:** true,
|
91
116
|
**Model Dependent:** false
|
92
117
|
|
93
|
-
|
94
|
-
|
95
|
-
Starting Time for Chilled Water Tank Charge in HR:mm (24 hour format)
|
118
|
+
### Enter Starting Time for Chilled Water Tank charge:
|
119
|
+
Use 24 hour format (HR:MM)
|
96
120
|
**Name:** charge_start,
|
97
121
|
**Type:** String,
|
98
122
|
**Units:** ,
|
99
123
|
**Required:** true,
|
100
124
|
**Model Dependent:** false
|
101
125
|
|
102
|
-
###
|
103
|
-
|
126
|
+
### Enter End Time for Chilled Water Tank charge:
|
127
|
+
Use 24 hour format (HR:MM)
|
104
128
|
**Name:** charge_end,
|
105
129
|
**Type:** String,
|
106
130
|
**Units:** ,
|
107
131
|
**Required:** true,
|
108
132
|
**Model Dependent:** false
|
109
133
|
|
110
|
-
### Work on
|
111
|
-
|
134
|
+
### Allow Chilled Water Tank Work on Weekends
|
135
|
+
|
112
136
|
**Name:** wknds,
|
113
137
|
**Type:** Boolean,
|
114
138
|
**Units:** ,
|
115
139
|
**Required:** true,
|
116
140
|
**Model Dependent:** false
|
117
141
|
|
142
|
+
### Output path for tank sizing run (if tank volume is not provided)
|
143
|
+
|
144
|
+
**Name:** run_output_path,
|
145
|
+
**Type:** Path,
|
146
|
+
**Units:** ,
|
147
|
+
**Required:** false,
|
148
|
+
**Model Dependent:** false
|
149
|
+
|
150
|
+
### epw file path for tank sizing run (if tank volume is not provided)
|
151
|
+
|
152
|
+
**Name:** epw_path,
|
153
|
+
**Type:** Path,
|
154
|
+
**Units:** ,
|
155
|
+
**Required:** false,
|
156
|
+
**Model Dependent:** false
|
157
|
+
|
118
158
|
|
119
159
|
|
120
160
|
|
@@ -559,6 +559,9 @@ class AddChilledWaterStorageTank < OpenStudio::Measure::ModelMeasure
|
|
559
559
|
sim_control.setRunSimulationforSizingPeriods(false)
|
560
560
|
sim_control.setRunSimulationforWeatherFileRunPeriods(true)
|
561
561
|
|
562
|
+
# TODO: add IF condition when there is existing secondary loop, just need to add new tank, no need to add pump
|
563
|
+
# TODO: test with large office building
|
564
|
+
|
562
565
|
sec_loop = OpenStudio::Model::PlantLoop.new(model)
|
563
566
|
sec_loop.setName("Chilled Water Secondary Loop")
|
564
567
|
selected_primary_loop.setName("Chilled Water Primary Loop")
|
@@ -640,6 +643,8 @@ class AddChilledWaterStorageTank < OpenStudio::Measure::ModelMeasure
|
|
640
643
|
end
|
641
644
|
end
|
642
645
|
|
646
|
+
# TODO: clone pump from either supply or demand side to secondary loop, update the primary loop pump pressure drop (check online)
|
647
|
+
# TODO: test with medium office
|
643
648
|
# move pump from demand component if any to secondary loop
|
644
649
|
selected_primary_loop.demandComponents.each do |comp|
|
645
650
|
if comp.to_PumpConstantSpeed.is_initialized
|
@@ -1,10 +1,10 @@
|
|
1
1
|
<?xml version="1.0"?>
|
2
2
|
<measure>
|
3
|
-
<schema_version>3.
|
3
|
+
<schema_version>3.1</schema_version>
|
4
4
|
<name>add_chilled_water_storage_tank</name>
|
5
5
|
<uid>8aafeff8-7798-43ab-8075-9cfe59a611b8</uid>
|
6
|
-
<version_id>
|
7
|
-
<version_modified>
|
6
|
+
<version_id>534953f6-ef6c-4921-92fb-d4396994351e</version_id>
|
7
|
+
<version_modified>2025-06-30T21:09:49Z</version_modified>
|
8
8
|
<xml_checksum>6394841D</xml_checksum>
|
9
9
|
<class_name>AddChilledWaterStorageTank</class_name>
|
10
10
|
<display_name>Add Chilled Water Storage Tank</display_name>
|
@@ -223,6 +223,18 @@
|
|
223
223
|
</attribute>
|
224
224
|
</attributes>
|
225
225
|
<files>
|
226
|
+
<file>
|
227
|
+
<filename>LICENSE.md</filename>
|
228
|
+
<filetype>md</filetype>
|
229
|
+
<usage_type>license</usage_type>
|
230
|
+
<checksum>BFFB1AA6</checksum>
|
231
|
+
</file>
|
232
|
+
<file>
|
233
|
+
<filename>README.md</filename>
|
234
|
+
<filetype>md</filetype>
|
235
|
+
<usage_type>readme</usage_type>
|
236
|
+
<checksum>107C2731</checksum>
|
237
|
+
</file>
|
226
238
|
<file>
|
227
239
|
<filename>README.md.erb</filename>
|
228
240
|
<filetype>erb</filetype>
|
@@ -235,12 +247,6 @@
|
|
235
247
|
<usage_type>doc</usage_type>
|
236
248
|
<checksum>00000000</checksum>
|
237
249
|
</file>
|
238
|
-
<file>
|
239
|
-
<filename>example_model.osm</filename>
|
240
|
-
<filetype>osm</filetype>
|
241
|
-
<usage_type>test</usage_type>
|
242
|
-
<checksum>53D14E69</checksum>
|
243
|
-
</file>
|
244
250
|
<file>
|
245
251
|
<version>
|
246
252
|
<software_program>OpenStudio</software_program>
|
@@ -250,13 +256,13 @@
|
|
250
256
|
<filename>measure.rb</filename>
|
251
257
|
<filetype>rb</filetype>
|
252
258
|
<usage_type>script</usage_type>
|
253
|
-
<checksum>
|
259
|
+
<checksum>8E1839DF</checksum>
|
254
260
|
</file>
|
255
261
|
<file>
|
256
|
-
<filename>
|
257
|
-
<filetype>
|
258
|
-
<usage_type>
|
259
|
-
<checksum>
|
262
|
+
<filename>CZ06RV2.epw</filename>
|
263
|
+
<filetype>epw</filetype>
|
264
|
+
<usage_type>test</usage_type>
|
265
|
+
<checksum>52282D70</checksum>
|
260
266
|
</file>
|
261
267
|
<file>
|
262
268
|
<filename>add_chilled_water_storage_tank_test.rb</filename>
|
@@ -265,16 +271,10 @@
|
|
265
271
|
<checksum>AC813F36</checksum>
|
266
272
|
</file>
|
267
273
|
<file>
|
268
|
-
<filename>
|
269
|
-
<filetype>
|
270
|
-
<usage_type>readme</usage_type>
|
271
|
-
<checksum>107C2731</checksum>
|
272
|
-
</file>
|
273
|
-
<file>
|
274
|
-
<filename>CZ06RV2.epw</filename>
|
275
|
-
<filetype>epw</filetype>
|
274
|
+
<filename>example_model.osm</filename>
|
275
|
+
<filetype>osm</filetype>
|
276
276
|
<usage_type>test</usage_type>
|
277
|
-
<checksum>
|
277
|
+
<checksum>53D14E69</checksum>
|
278
278
|
</file>
|
279
279
|
<file>
|
280
280
|
<filename>restaurant.osm</filename>
|