- checksums.yaml +4 -4
- data/.gitignore +3 -2
- data/Gemfile +6 -1
- data/lib/measures/Add Output Variable/measure.xml +128 -125
- data/lib/measures/AddElectricVehicleChargingLoad/measure.xml +24 -23
- data/lib/measures/AdjustThermostatSetpointsByDegreesForPeakHours/README.md +22 -16
- data/lib/measures/AdjustThermostatSetpointsByDegreesForPeakHours/measure.xml +41 -30
- data/lib/measures/Enable Demand Controlled Ventilation/measure.xml +14 -13
- data/lib/measures/GEB Metrics Report/measure.rb +5 -5
- data/lib/measures/GEB Metrics Report/measure.xml +238 -23
- data/lib/measures/add_ceiling_fan/measure.xml +25 -25
- data/lib/measures/add_chilled_water_storage_tank/measure.xml +201 -28
- data/lib/measures/add_chilled_water_storage_tank/tests/example_model.osm +8077 -21624
- data/lib/measures/add_electrochromic_window/measure.xml +28 -27
- data/lib/measures/add_exterior_blinds_and_control/measure.xml +15 -26
- data/lib/measures/add_heat_pump_water_heater/measure.xml +89 -17
- data/lib/measures/add_interior_blinds_and_control/measure.xml +21 -33
- data/lib/measures/add_natural_ventilation_with_hybrid_control/README.md +4 -4
- data/lib/measures/add_natural_ventilation_with_hybrid_control/measure.rb +2 -2
- data/lib/measures/add_natural_ventilation_with_hybrid_control/measure.xml +36 -30
- data/lib/measures/add_natural_ventilation_with_hybrid_control/tests/CZ06RV2.epw +8768 -0
- data/lib/measures/add_rooftop_pv_simple/measure.xml +11 -5
- data/lib/measures/adjust_dhw_setpoint/measure.xml +34 -21
- data/lib/measures/average_ventilation_for_peak_hours/README.md +5 -45
- data/lib/measures/average_ventilation_for_peak_hours/measure.xml +24 -79
- data/lib/measures/enable_occupancy_driven_lighting/measure.xml +28 -27
- data/lib/measures/precooling/measure.xml +12 -11
- data/lib/measures/preheating/measure.xml +18 -17
- data/lib/measures/reduce_domestic_hot_water_use_for_peak_hours/measure.xml +34 -27
- data/lib/measures/reduce_epd_by_percentage_for_peak_hours/README.md +3 -3
- data/lib/measures/reduce_epd_by_percentage_for_peak_hours/measure.xml +25 -18
- data/lib/measures/reduce_exterior_lighting_loads/measure.xml +25 -25
- data/lib/measures/reduce_lpd_by_percentage_for_peak_hours/measure.xml +30 -23
- data/lib/openstudio/geb/version.rb +1 -1
- metadata +5 -4
@@ -1,9 +1,10 @@
|
|
1
|
+
<?xml version="1.0"?>
|
1
2
|
<measure>
|
2
3
|
<schema_version>3.0</schema_version>
|
3
4
|
<name>add_chilled_water_storage_tank</name>
|
4
5
|
<uid>8aafeff8-7798-43ab-8075-9cfe59a611b8</uid>
|
5
|
-
<version_id>
|
6
|
-
<version_modified>
|
6
|
+
<version_id>762ec571-fcf5-4617-a95a-5aaa2951f61d</version_id>
|
7
|
+
<version_modified>20230719T172112Z</version_modified>
|
7
8
|
<xml_checksum>6394841D</xml_checksum>
|
8
9
|
<class_name>AddChilledWaterStorageTank</class_name>
|
9
10
|
<display_name>Add Chilled Water Storage Tank</display_name>
|
@@ -11,16 +12,176 @@
|
|
11
12
|
<modeler_description>This measure adds a chilled water storage tank and links it to an existing chilled water loop.</modeler_description>
|
12
13
|
<arguments>
|
13
14
|
<argument>
|
14
|
-
<name>
|
15
|
-
<display_name>
|
16
|
-
<
|
15
|
+
<name>tank_vol</name>
|
16
|
+
<display_name>Thermal storage chilled water tank volume in m3</display_name>
|
17
|
+
<type>Double</type>
|
18
|
+
<required>false</required>
|
19
|
+
<model_dependent>false</model_dependent>
|
20
|
+
</argument>
|
21
|
+
<argument>
|
22
|
+
<name>objective</name>
|
23
|
+
<display_name>Select Energy Storage Objective:</display_name>
|
24
|
+
<type>Choice</type>
|
25
|
+
<required>true</required>
|
26
|
+
<model_dependent>false</model_dependent>
|
27
|
+
<default_value>Partial Storage</default_value>
|
28
|
+
<choices>
|
29
|
+
<choice>
|
30
|
+
<value>Full Storage</value>
|
31
|
+
<display_name>Full Storage</display_name>
|
32
|
+
</choice>
|
33
|
+
<choice>
|
34
|
+
<value>Partial Storage</value>
|
35
|
+
<display_name>Partial Storage</display_name>
|
36
|
+
</choice>
|
37
|
+
</choices>
|
38
|
+
</argument>
|
39
|
+
<argument>
|
40
|
+
<name>selected_primary_loop_name</name>
|
41
|
+
<display_name>Select Primary Loop:</display_name>
|
42
|
+
<description>Error: No Cooling Loop Found</description>
|
43
|
+
<type>Choice</type>
|
44
|
+
<required>false</required>
|
45
|
+
<model_dependent>false</model_dependent>
|
46
|
+
<default_value></default_value>
|
47
|
+
<choices>
|
48
|
+
<choice>
|
49
|
+
<value></value>
|
50
|
+
<display_name></display_name>
|
51
|
+
</choice>
|
52
|
+
</choices>
|
53
|
+
</argument>
|
54
|
+
<argument>
|
55
|
+
<name>primary_loop_sp</name>
|
56
|
+
<display_name>Primary Loop (charging) Setpoint Temperature degree C:</display_name>
|
57
|
+
<type>Double</type>
|
58
|
+
<required>true</required>
|
59
|
+
<model_dependent>false</model_dependent>
|
60
|
+
<default_value>6.7</default_value>
|
61
|
+
</argument>
|
62
|
+
<argument>
|
63
|
+
<name>secondary_loop_sp</name>
|
64
|
+
<display_name>Secondary Loop (discharging) Setpoint Temperature degree C:</display_name>
|
65
|
+
<type>Double</type>
|
66
|
+
<required>true</required>
|
67
|
+
<model_dependent>false</model_dependent>
|
68
|
+
<default_value>6.7</default_value>
|
69
|
+
</argument>
|
70
|
+
<argument>
|
71
|
+
<name>tank_charge_sp</name>
|
72
|
+
<display_name>Chilled Water Tank Setpoint Temperature degree C:</display_name>
|
73
|
+
<type>Double</type>
|
74
|
+
<required>true</required>
|
75
|
+
<model_dependent>false</model_dependent>
|
76
|
+
<default_value>6.7</default_value>
|
77
|
+
</argument>
|
78
|
+
<argument>
|
79
|
+
<name>primary_delta_t</name>
|
80
|
+
<display_name>Loop Design Temperature Difference degree C:</display_name>
|
81
|
+
<description>Enter numeric value to adjust selected loop settings.</description>
|
17
82
|
<type>String</type>
|
18
83
|
<required>true</required>
|
19
84
|
<model_dependent>false</model_dependent>
|
85
|
+
<default_value>Use Existing Loop Value</default_value>
|
86
|
+
</argument>
|
87
|
+
<argument>
|
88
|
+
<name>secondary_delta_t</name>
|
89
|
+
<display_name>Secondary Loop Design Temperature Difference degree C</display_name>
|
90
|
+
<type>Double</type>
|
91
|
+
<required>true</required>
|
92
|
+
<model_dependent>false</model_dependent>
|
93
|
+
<default_value>4.5</default_value>
|
94
|
+
</argument>
|
95
|
+
<argument>
|
96
|
+
<name>thermal_storage_startdate</name>
|
97
|
+
<display_name>Start Date for thermal storage</display_name>
|
98
|
+
<description>In MM-DD format</description>
|
99
|
+
<type>String</type>
|
100
|
+
<required>false</required>
|
101
|
+
<model_dependent>false</model_dependent>
|
102
|
+
<default_value>01-01</default_value>
|
103
|
+
</argument>
|
104
|
+
<argument>
|
105
|
+
<name>thermal_storage_enddate</name>
|
106
|
+
<display_name>End Date for thermal storage</display_name>
|
107
|
+
<description>In MM-DD format</description>
|
108
|
+
<type>String</type>
|
109
|
+
<required>false</required>
|
110
|
+
<model_dependent>false</model_dependent>
|
111
|
+
<default_value>12-31</default_value>
|
112
|
+
</argument>
|
113
|
+
<argument>
|
114
|
+
<name>discharge_start</name>
|
115
|
+
<display_name>Enter Starting Time for Chilled Water Tank Discharge:</display_name>
|
116
|
+
<description>Use 24 hour format (HR:MM)</description>
|
117
|
+
<type>String</type>
|
118
|
+
<required>true</required>
|
119
|
+
<model_dependent>false</model_dependent>
|
120
|
+
<default_value>08:00</default_value>
|
121
|
+
</argument>
|
122
|
+
<argument>
|
123
|
+
<name>discharge_end</name>
|
124
|
+
<display_name>Enter End Time for Chilled Water Tank Discharge:</display_name>
|
125
|
+
<description>Use 24 hour format (HR:MM)</description>
|
126
|
+
<type>String</type>
|
127
|
+
<required>true</required>
|
128
|
+
<model_dependent>false</model_dependent>
|
129
|
+
<default_value>21:00</default_value>
|
130
|
+
</argument>
|
131
|
+
<argument>
|
132
|
+
<name>charge_start</name>
|
133
|
+
<display_name>Enter Starting Time for Chilled Water Tank charge:</display_name>
|
134
|
+
<description>Use 24 hour format (HR:MM)</description>
|
135
|
+
<type>String</type>
|
136
|
+
<required>true</required>
|
137
|
+
<model_dependent>false</model_dependent>
|
138
|
+
<default_value>23:00</default_value>
|
139
|
+
</argument>
|
140
|
+
<argument>
|
141
|
+
<name>charge_end</name>
|
142
|
+
<display_name>Enter End Time for Chilled Water Tank charge:</display_name>
|
143
|
+
<description>Use 24 hour format (HR:MM)</description>
|
144
|
+
<type>String</type>
|
145
|
+
<required>true</required>
|
146
|
+
<model_dependent>false</model_dependent>
|
147
|
+
<default_value>07:00</default_value>
|
148
|
+
</argument>
|
149
|
+
<argument>
|
150
|
+
<name>wknds</name>
|
151
|
+
<display_name>Allow Chilled Water Tank Work on Weekends</display_name>
|
152
|
+
<type>Boolean</type>
|
153
|
+
<required>true</required>
|
154
|
+
<model_dependent>false</model_dependent>
|
155
|
+
<default_value>false</default_value>
|
156
|
+
<choices>
|
157
|
+
<choice>
|
158
|
+
<value>true</value>
|
159
|
+
<display_name>true</display_name>
|
160
|
+
</choice>
|
161
|
+
<choice>
|
162
|
+
<value>false</value>
|
163
|
+
<display_name>false</display_name>
|
164
|
+
</choice>
|
165
|
+
</choices>
|
166
|
+
</argument>
|
167
|
+
<argument>
|
168
|
+
<name>run_output_path</name>
|
169
|
+
<display_name>Output path for tank sizing run (if tank volume is not provided)</display_name>
|
170
|
+
<type>Path</type>
|
171
|
+
<required>false</required>
|
172
|
+
<model_dependent>false</model_dependent>
|
173
|
+
<default_value>"."</default_value>
|
174
|
+
</argument>
|
175
|
+
<argument>
|
176
|
+
<name>epw_path</name>
|
177
|
+
<display_name>epw file path for tank sizing run (if tank volume is not provided)</display_name>
|
178
|
+
<type>Path</type>
|
179
|
+
<required>false</required>
|
180
|
+
<model_dependent>false</model_dependent>
|
20
181
|
</argument>
|
21
182
|
</arguments>
|
22
|
-
<outputs/>
|
23
|
-
<provenances/>
|
183
|
+
<outputs />
|
184
|
+
<provenances />
|
24
185
|
<tags>
|
25
186
|
<tag>HVAC.Cooling</tag>
|
26
187
|
</tags>
|
@@ -62,6 +223,24 @@
|
|
62
223
|
</attribute>
|
63
224
|
</attributes>
|
64
225
|
<files>
|
226
|
+
<file>
|
227
|
+
<filename>README.md.erb</filename>
|
228
|
+
<filetype>erb</filetype>
|
229
|
+
<usage_type>readmeerb</usage_type>
|
230
|
+
<checksum>703C9964</checksum>
|
231
|
+
</file>
|
232
|
+
<file>
|
233
|
+
<filename>.gitkeep</filename>
|
234
|
+
<filetype>gitkeep</filetype>
|
235
|
+
<usage_type>doc</usage_type>
|
236
|
+
<checksum>00000000</checksum>
|
237
|
+
</file>
|
238
|
+
<file>
|
239
|
+
<filename>example_model.osm</filename>
|
240
|
+
<filetype>osm</filetype>
|
241
|
+
<usage_type>test</usage_type>
|
242
|
+
<checksum>53D14E69</checksum>
|
243
|
+
</file>
|
65
244
|
<file>
|
66
245
|
<version>
|
67
246
|
<software_program>OpenStudio</software_program>
|
@@ -71,43 +250,37 @@
|
|
71
250
|
<filename>measure.rb</filename>
|
72
251
|
<filetype>rb</filetype>
|
73
252
|
<usage_type>script</usage_type>
|
74
|
-
<checksum>
|
253
|
+
<checksum>EFE2DEC1</checksum>
|
75
254
|
</file>
|
76
255
|
<file>
|
77
256
|
<filename>LICENSE.md</filename>
|
78
257
|
<filetype>md</filetype>
|
79
258
|
<usage_type>license</usage_type>
|
80
|
-
<checksum>
|
259
|
+
<checksum>BFFB1AA6</checksum>
|
81
260
|
</file>
|
82
261
|
<file>
|
83
|
-
<filename>
|
84
|
-
<filetype>
|
85
|
-
<usage_type>
|
86
|
-
<checksum>
|
262
|
+
<filename>add_chilled_water_storage_tank_test.rb</filename>
|
263
|
+
<filetype>rb</filetype>
|
264
|
+
<usage_type>test</usage_type>
|
265
|
+
<checksum>AC813F36</checksum>
|
87
266
|
</file>
|
88
267
|
<file>
|
89
|
-
<filename
|
90
|
-
<filetype>
|
91
|
-
<usage_type>
|
92
|
-
<checksum>
|
268
|
+
<filename>README.md</filename>
|
269
|
+
<filetype>md</filetype>
|
270
|
+
<usage_type>readme</usage_type>
|
271
|
+
<checksum>107C2731</checksum>
|
93
272
|
</file>
|
94
273
|
<file>
|
95
|
-
<filename>
|
96
|
-
<filetype>
|
274
|
+
<filename>CZ06RV2.epw</filename>
|
275
|
+
<filetype>epw</filetype>
|
97
276
|
<usage_type>test</usage_type>
|
98
|
-
<checksum>
|
277
|
+
<checksum>52282D70</checksum>
|
99
278
|
</file>
|
100
279
|
<file>
|
101
|
-
<filename>
|
280
|
+
<filename>restaurant.osm</filename>
|
102
281
|
<filetype>osm</filetype>
|
103
282
|
<usage_type>test</usage_type>
|
104
|
-
<checksum>
|
105
|
-
</file>
|
106
|
-
<file>
|
107
|
-
<filename>README.md</filename>
|
108
|
-
<filetype>md</filetype>
|
109
|
-
<usage_type>readme</usage_type>
|
110
|
-
<checksum>1EBF4EB5</checksum>
|
283
|
+
<checksum>75E857EB</checksum>
|
111
284
|
</file>
|
112
285
|
</files>
|
113
286
|
</measure>
|