openstudio-common-measures 0.5.0 → 0.6.0
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- checksums.yaml +4 -4
- data/CHANGELOG.md +12 -1
- data/README.md +7 -2
- data/doc_templates/copyright_erb.txt +1 -1
- data/lib/measures/AddCostPerFloorAreaUnusedToLights/measure.xml +2 -8
- data/lib/measures/AddCostToSupplySideHVACComponentByAirLoop/measure.xml +9 -3
- data/lib/measures/AddSimplePvToShadingSurfacesByType/measure.xml +2 -2
- data/lib/measures/RemoveUnusedDefaultProfiles/measure.xml +2 -2
- data/lib/measures/ReportModelChanges/measure.xml +2 -2
- data/lib/measures/SetCOPforSingleSpeedDXCoolingUnits/measure.xml +4 -4
- data/lib/measures/SetCOPforTwoSpeedDXCoolingUnits/measure.xml +4 -4
- data/lib/measures/SetGasBurnerEfficiency/measure.xml +4 -4
- data/lib/measures/ShiftScheduleProfileTime/measure.xml +4 -4
- data/lib/measures/SwapLightsDefinition/measure.xml +3 -5
- data/lib/measures/add_ems_emissions_reporting/measure.rb +236 -29
- data/lib/measures/add_ems_emissions_reporting/measure.xml +362 -10
- data/lib/measures/add_ev_load/measure.rb +51 -8
- data/lib/measures/add_ev_load/measure.xml +23 -5
- data/lib/measures/envelope_and_internal_load_breakdown/measure.xml +3 -3
- data/lib/measures/envelope_and_internal_load_breakdown/resources/report.html.erb +5 -1
- data/lib/measures/example_report/measure.xml +3 -3
- data/lib/measures/example_report/resources/report.html.erb +5 -1
- data/lib/measures/generic_qaqc/README.md +19 -4
- data/lib/measures/generic_qaqc/README.md.erb +7 -1
- data/lib/measures/generic_qaqc/docs/generic_qaqc_detailed.jpg +0 -0
- data/lib/measures/generic_qaqc/docs/generic_qaqc_summary.jpg +0 -0
- data/lib/measures/generic_qaqc/measure.rb +34 -29
- data/lib/measures/generic_qaqc/measure.xml +181 -82
- data/lib/measures/generic_qaqc/resources/check_cond_zns.rb +3 -1
- data/lib/measures/generic_qaqc/resources/check_domestic_hot_water.rb +13 -8
- data/lib/measures/generic_qaqc/resources/check_envelope_conductance.rb +330 -231
- data/lib/measures/generic_qaqc/resources/check_eui_by_end_use.rb +59 -20
- data/lib/measures/generic_qaqc/resources/check_eui_reasonableness.rb +58 -20
- data/lib/measures/generic_qaqc/resources/check_internal_loads.rb +57 -56
- data/lib/measures/generic_qaqc/resources/check_mech_sys_capacity.rb +4 -1
- data/lib/measures/generic_qaqc/resources/check_mech_sys_efficiency.rb +27 -22
- data/lib/measures/generic_qaqc/resources/check_mech_sys_part_load_eff.rb +4 -1
- data/lib/measures/generic_qaqc/resources/check_mech_sys_type.rb +3 -3
- data/lib/measures/generic_qaqc/resources/check_schedules.rb +65 -101
- data/lib/measures/generic_qaqc/resources/check_simultaneous_heating_and_cooling.rb +3 -1
- data/lib/measures/generic_qaqc/resources/check_supply_air_and_thermostat_temp_difference.rb +3 -1
- data/lib/measures/generic_qaqc/resources/os_lib_reporting_qaqc.rb +49 -15
- data/lib/measures/generic_qaqc/resources/report.html.erb +5 -1
- data/lib/measures/hvac_psychrometric_chart/measure.xml +3 -3
- data/lib/measures/hvac_psychrometric_chart/resources/report.html.erb +5 -1
- data/lib/measures/openstudio_results/measure.xml +3 -3
- data/lib/measures/openstudio_results/resources/report.html.erb +5 -1
- data/lib/measures/set_run_period/measure.xml +2 -2
- data/lib/measures/view_data/measure.xml +4 -4
- data/lib/measures/view_data/resources/report.html.in +189 -19
- data/lib/measures/view_data/resources/va3c.rb +1 -0
- data/lib/measures/view_model/measure.xml +9 -9
- data/lib/measures/view_model/resources/report.html.in +189 -19
- data/lib/measures/view_model/resources/va3c.rb +1 -0
- data/lib/openstudio/common_measures/version.rb +1 -1
- data/openstudio-common-measures.gemspec +1 -1
- metadata +7 -5
@@ -49,11 +49,14 @@ module OsLib_QAQC
|
|
49
49
|
else
|
50
50
|
check_elems << OpenStudio::Attribute.new('description', 'Check against the 2011 ASHRAE Handbook - HVAC Applications, Table 7 section 50.14.')
|
51
51
|
end
|
52
|
-
|
52
|
+
check_elems << OpenStudio::Attribute.new('min_pass', min_pass * 100)
|
53
|
+
check_elems << OpenStudio::Attribute.new('max_pass', max_pass * 100)
|
54
|
+
|
53
55
|
# stop here if only name is requested this is used to populate display name for arguments
|
54
56
|
if name_only == true
|
55
57
|
results = []
|
56
58
|
check_elems.each do |elem|
|
59
|
+
next if ['Double','Integer'].include? (elem.valueType.valueDescription)
|
57
60
|
results << elem.valueAsString
|
58
61
|
end
|
59
62
|
return results
|
@@ -158,7 +161,7 @@ module OsLib_QAQC
|
|
158
161
|
|
159
162
|
space_type_num_people_hours = 0.0
|
160
163
|
# loop through peole instances
|
161
|
-
space_type.
|
164
|
+
space_type.people.each do |inst|
|
162
165
|
inst_num_people = inst.getNumberOfPeople(space_type_floor_area)
|
163
166
|
inst_schedule = inst.numberofPeopleSchedule.get # sim will fail prior to this if doesn't have it
|
164
167
|
|
@@ -185,7 +188,7 @@ module OsLib_QAQC
|
|
185
188
|
|
186
189
|
num_people_hours += space_type_num_people_hours
|
187
190
|
end
|
188
|
-
num_meals = num_people_hours / 365.0 * 1.5 # 90 minute meal
|
191
|
+
num_meals = num_people_hours / (365.0 * 1.5) # 90 minute meal
|
189
192
|
target_consumption = num_meals * ashrae_hot_water_demand.first[:avg_day_unit]
|
190
193
|
|
191
194
|
elsif ['LargeHotel', 'SmallHotel'].include? building_type
|
@@ -287,7 +290,7 @@ module OsLib_QAQC
|
|
287
290
|
|
288
291
|
num_people_hours += space_type_num_people_hours
|
289
292
|
end
|
290
|
-
num_meals = num_people_hours / 365.0 * 0.5 # 30 minute leal
|
293
|
+
num_meals = num_people_hours / (365.0 * 0.5) # 30 minute leal
|
291
294
|
# todo - add logic to address drive through traffic
|
292
295
|
target_consumption = num_meals * ashrae_hot_water_demand.first[:avg_day_unit]
|
293
296
|
|
@@ -312,10 +315,12 @@ module OsLib_QAQC
|
|
312
315
|
end
|
313
316
|
|
314
317
|
# check actual against target
|
315
|
-
if
|
316
|
-
|
317
|
-
|
318
|
-
|
318
|
+
if !target_consumption.nil?
|
319
|
+
if service_water_consumption_daily_avg_gal < target_consumption * (1.0 - min_pass)
|
320
|
+
check_elems << OpenStudio::Attribute.new('flag', "Annual average of #{service_water_consumption_daily_avg_gal.round} gallons per day of hot water is more than #{min_pass * 100} % below the value of #{target_consumption.round} gallons per day.")
|
321
|
+
elsif service_water_consumption_daily_avg_gal > target_consumption * (1.0 + max_pass)
|
322
|
+
check_elems << OpenStudio::Attribute.new('flag', "Annual average of #{service_water_consumption_daily_avg_gal.round} gallons per day of hot water is more than #{max_pass * 100} % above the value of #{target_consumption.round} gallons per day.")
|
323
|
+
end
|
319
324
|
end
|
320
325
|
rescue StandardError => e
|
321
326
|
# brief description of ruby error
|