horn_acoustics 0.1.0

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
checksums.yaml ADDED
@@ -0,0 +1,7 @@
1
+ ---
2
+ SHA256:
3
+ metadata.gz: d6a4cc1ceec8ae784151b7118528d08b7cf1adf0c332cb440923d618499617ed
4
+ data.tar.gz: 60afe532fecdd5b21228414d9eee5c5910073cf20bdacbd41d97d0816c03f01b
5
+ SHA512:
6
+ metadata.gz: 7131af54a4dbb02888d88def7f0b43b3216d569998ecf81a207ef232686c434df332fb1ef8a5b51f8548f2f08f08f0f17819aeb481983b65cb3fe661245a1e2f
7
+ data.tar.gz: 17e73e1192e7d666b4eda830841104bc2e3ccddad2dd9e7ad94e15cfceae092b3c5aed232546994080bd2ee3c00d7fe7ec918685ae99b9b3998352193e0dd781
data/LICENSE ADDED
@@ -0,0 +1,21 @@
1
+ MIT License
2
+
3
+ Copyright (c) 2026 Horn Guns
4
+
5
+ Permission is hereby granted, free of charge, to any person obtaining a copy
6
+ of this software and associated documentation files (the "Software"), to deal
7
+ in the Software without restriction, including without limitation the rights
8
+ to use, copy, modify, merge, publish, distribute, sublicense, and/or sell
9
+ copies of the Software, and to permit persons to whom the Software is
10
+ furnished to do so, subject to the following conditions:
11
+
12
+ The above copyright notice and this permission notice shall be included in all
13
+ copies or substantial portions of the Software.
14
+
15
+ THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR
16
+ IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY,
17
+ FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE
18
+ AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER
19
+ LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM,
20
+ OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE
21
+ SOFTWARE.
data/README.md ADDED
@@ -0,0 +1,83 @@
1
+ # horn_acoustics
2
+
3
+ Small helpers for outdoor acoustics calculations that come up when
4
+ working with train horns — locomotive horns at a grade crossing, and
5
+ also portable and battery-powered train horns used for signalling away
6
+ from the rail right-of-way. The library covers how the sound-pressure
7
+ level of a point source changes with distance, how much air absorbs a
8
+ tone, the Doppler shift of a moving source or observer, the sounding
9
+ window required at a U.S. public highway-rail grade crossing, and the
10
+ equal-tempered frequencies of a multi-chime horn.
11
+
12
+ Every formula is taken from a published standard or regulation:
13
+
14
+ - inverse-square (spherical) spreading: ISO 9613-2:1996, clause 7.1
15
+ - atmospheric absorption: ISO 9613-1:1993, equations (3)--(5) and Annex B
16
+ - speed of sound versus temperature: ISO 2533:1975
17
+ - classical Doppler formula for a source and observer in a still medium
18
+ - locomotive-horn sounding window: 49 CFR 222.21 (b)(2)--(b)(3) only
19
+ - A4 = 440 Hz, twelve-tone equal temperament: ISO 16:1975
20
+
21
+ The gem does not invent spectra, empirical horn data, or fitted
22
+ constants. Background on this class of device is collected at
23
+ [Horn Guns](https://hornguns.com/).
24
+
25
+ ## Installation
26
+
27
+ Once the gem is on RubyGems it can be installed with:
28
+
29
+ ```bash
30
+ gem install horn_acoustics
31
+ ```
32
+
33
+ From a local `.gem` file:
34
+
35
+ ```bash
36
+ gem install horn_acoustics-0.1.0.gem
37
+ ```
38
+
39
+ In a Gemfile:
40
+
41
+ ```ruby
42
+ gem "horn_acoustics", "0.1.0"
43
+ ```
44
+
45
+ ## Usage
46
+
47
+ ```ruby
48
+ require "horn_acoustics"
49
+
50
+ # Level of a 1 kHz tone 100 m from a source that is 110 dB at 1 m,
51
+ # including ISO 9613-1 atmospheric absorption at 20 °C and 50 % RH
52
+ HornAcoustics.spl_at_distance(
53
+ 110, 100, distance_ref: 1,
54
+ absorption: true, frequency: 1000
55
+ )
56
+
57
+ # Frequencies of a three-chime train-horn major triad, then the
58
+ # Doppler-shifted tones heard by a wayside observer as the train
59
+ # approaches at 30 m/s
60
+ notes = HornAcoustics.chord_frequencies(["D4", "F#4", "A4"])
61
+ HornAcoustics.doppler_shift(
62
+ notes.values,
63
+ source_speed: 30,
64
+ source_towards_observer: true
65
+ )
66
+
67
+ # 49 CFR 222.21 sounding window versus train speed
68
+ HornAcoustics.horn_window([45, 60, 80], distance_unit: "ft")
69
+ ```
70
+
71
+ The same calculations apply whether the source is a locomotive horn or a
72
+ portable, battery-powered train horn: spherical spreading and air
73
+ absorption depend on level, distance, frequency and weather, not on how
74
+ the horn is powered.
75
+
76
+ ## References
77
+
78
+ - ISO 9613-1:1993. *Acoustics — Attenuation of sound during propagation outdoors — Part 1: Calculation of the absorption of sound by the atmosphere.*
79
+ - ISO 9613-2:1996. *Acoustics — Attenuation of sound during propagation outdoors — Part 2: General method of calculation.*
80
+ - ISO 2533:1975. *Standard Atmosphere.*
81
+ - ISO 16:1975. *Acoustics — Standard tuning frequency (Standard musical pitch).*
82
+ - 49 CFR 222.21, *When must a locomotive horn be used?*
83
+ <https://www.ecfr.gov/current/title-49/section-222.21>
@@ -0,0 +1,139 @@
1
+ # frozen_string_literal: true
2
+
3
+ module HornAcoustics
4
+ # Atmospheric absorption coefficient (ISO 9613-1:1993).
5
+ module AtmosphericAbsorption
6
+ # ISO 9613-1:1993 clause 4.2 reference temperature, in kelvin.
7
+ T0 = 293.15
8
+ # Triple-point temperature of water, in kelvin (ISO 9613-1 Annex B).
9
+ T01 = 273.16
10
+ # ISO 9613-1:1993 reference pressure, in kilopascals (one standard atmosphere).
11
+ PR = 101.325
12
+
13
+ module_function
14
+
15
+ # Pure-tone atmospheric absorption coefficient α from ISO 9613-1:1993,
16
+ # equations (3)–(5) and the Annex B conversion from relative humidity
17
+ # to molar concentration of water vapour.
18
+ #
19
+ # The coefficient, in decibels per metre, is
20
+ #
21
+ # α = 8.686 f² { 1.84×10⁻¹¹ (p_a/p_r)⁻¹ (T/T₀)^(1/2)
22
+ # + (T/T₀)^(-5/2) [ 0.01275 e^(-2239.1/T) (f_rO + f²/f_rO)⁻¹
23
+ # + 0.1068 e^(-3352.0/T) (f_rN + f²/f_rN)⁻¹ ] }
24
+ #
25
+ # with oxygen and nitrogen relaxation frequencies
26
+ #
27
+ # f_rO = (p_a/p_r) [ 24 + 4.04×10⁴ h (0.02+h)/(0.391+h) ]
28
+ # f_rN = (p_a/p_r) (T/T₀)^(-1/2)
29
+ # { 9 + 280 h exp[ -4.170 ((T/T₀)^(-1/3) - 1) ] }
30
+ #
31
+ # The constants T₀ = 293.15 K and p_r = 101.325 kPa are the reference
32
+ # conditions of ISO 9613-1:1993, clause 4.2. The molar concentration
33
+ # of water vapour h, as a percentage, is h = h_r (p_sat / p_a), with
34
+ # p_sat/p_r = 10^(-6.8346 (T₀₁/T)^1.261 + 4.6151) and T₀₁ = 273.16 K
35
+ # (triple-point temperature of water), from Annex B of the same
36
+ # standard. All numerical coefficients are those printed in the
37
+ # standard; none are fitted or invented.
38
+ #
39
+ # ISO 9613-1:1993 states an accuracy of about ±10 % for temperatures
40
+ # from −20 to +50 °C and molar concentrations of water vapour between
41
+ # 0.05 % and 5 % (clause 7). Tabulated values in the standard cover
42
+ # 50 Hz to 10 kHz; the same equations are specified for use outside
43
+ # that frequency grid.
44
+ #
45
+ # @param frequency [Numeric, Array<Numeric>] sound frequency, in hertz.
46
+ # Must be positive.
47
+ # @param temperature [Numeric, Array<Numeric>] air temperature, in
48
+ # degrees Celsius. Defaults to 20 °C, the ISO 9613-1 reference
49
+ # temperature.
50
+ # @param humidity [Numeric, Array<Numeric>] relative humidity, as a
51
+ # percentage in [0, 100]. Defaults to 50.
52
+ # @param pressure [Numeric, Array<Numeric>] ambient atmospheric
53
+ # pressure, in kilopascals. Defaults to 101.325 kPa (one standard
54
+ # atmosphere).
55
+ # @param unit [String] unit of the returned coefficient: `"dB/m"`
56
+ # (the unit of ISO 9613-1 equation (5)) or `"dB/km"` (the unit of
57
+ # Table 1 of the standard).
58
+ #
59
+ # @return [Float, Array<Float>] attenuation coefficient(s) in the
60
+ # requested unit. An array is returned when any input is an array.
61
+ #
62
+ # @raise [ArgumentError] if a frequency or pressure is not positive,
63
+ # humidity is outside [0, 100], temperature is at or below absolute
64
+ # zero, or +unit+ is not `"dB/m"` or `"dB/km"`.
65
+ #
66
+ # @note A warning is issued if any temperature lies outside the
67
+ # −20 to +50 °C accuracy range stated in ISO 9613-1:1993.
68
+ #
69
+ # @example About 4.66 dB/km at 1 kHz, 20 °C, 50 % RH, 1 atm
70
+ # HornAcoustics.atmospheric_absorption(1000, unit: "dB/km")
71
+ #
72
+ # @example Absorption rises with frequency in the audio band
73
+ # HornAcoustics.atmospheric_absorption([125, 250, 500, 1000, 2000], unit: "dB/km")
74
+ #
75
+ # @see HornAcoustics.spl_at_distance
76
+ # @see https://www.iso.org/standard/17426.html ISO 9613-1:1993
77
+ #
78
+ # @reference International Organization for Standardization (1993).
79
+ # *Acoustics — Attenuation of sound during propagation outdoors —
80
+ # Part 1: Calculation of the absorption of sound by the atmosphere.*
81
+ # ISO 9613-1:1993.
82
+ def atmospheric_absorption(frequency, temperature: 20, humidity: 50,
83
+ pressure: 101.325, unit: "dB/m")
84
+ unless %w[dB/m dB/km].include?(unit)
85
+ raise ArgumentError, 'unit must be "dB/m" or "dB/km".'
86
+ end
87
+
88
+ Util.check_positive_each(frequency, "frequency")
89
+ Util.check_positive_each(pressure, "pressure")
90
+ Util.check_numeric_each(humidity, "humidity")
91
+ Util.check_numeric_each(temperature, "temperature")
92
+
93
+ freqs, temps, hums, press = Util.broadcast(frequency, temperature, humidity, pressure)
94
+
95
+ if hums.any? { |h| h < 0 || h > 100 }
96
+ raise ArgumentError,
97
+ "humidity must be a relative humidity in [0, 100] percent."
98
+ end
99
+
100
+ if temps.any? { |t| t < -20 || t > 50 }
101
+ warn "ISO 9613-1:1993 states its +/- 10% accuracy for temperatures " \
102
+ "from -20 to +50 degrees Celsius."
103
+ end
104
+
105
+ alphas = freqs.zip(temps, hums, press).map do |f, t_c, rh, p_a|
106
+ coefficient_db_per_m(f, t_c, rh, p_a)
107
+ end
108
+ alphas = alphas.map { |a| a * 1000.0 } if unit == "dB/km"
109
+ Util.maybe_scalar(alphas, frequency, temperature, humidity, pressure)
110
+ end
111
+
112
+ # ISO 9613-1:1993 equation (5), in dB/m, with Annex B humidity and
113
+ # equations (3)–(4) for the relaxation frequencies.
114
+ # @api private
115
+ def coefficient_db_per_m(frequency, temperature_c, humidity, pressure)
116
+ t_k = Util.to_kelvin(temperature_c)
117
+ # Annex B: saturation vapour pressure ratio and molar concentration h (%).
118
+ c = -6.8346 * ((T01 / t_k)**1.261) + 4.6151
119
+ psat_over_pr = 10**c
120
+ h = humidity * (psat_over_pr / (pressure / PR))
121
+
122
+ # Equations (3) and (4).
123
+ fr_o = (pressure / PR) * (24.0 + 4.04e4 * h * (0.02 + h) / (0.391 + h))
124
+ fr_n = (pressure / PR) * ((t_k / T0)**(-0.5)) *
125
+ (9.0 + 280.0 * h * Math.exp(-4.170 * (((t_k / T0)**(-1.0 / 3.0)) - 1.0)))
126
+
127
+ # Equation (5), in dB/m. The leading factor 8.686 is as printed in the
128
+ # standard (20 / ln(10) rounded to four significant figures).
129
+ 8.686 * (frequency**2) * (
130
+ 1.84e-11 * ((pressure / PR)**(-1)) * ((t_k / T0)**0.5) +
131
+ ((t_k / T0)**(-2.5)) * (
132
+ 0.01275 * Math.exp(-2239.1 / t_k) * ((fr_o + (frequency**2) / fr_o)**(-1)) +
133
+ 0.1068 * Math.exp(-3352.0 / t_k) * ((fr_n + (frequency**2) / fr_n)**(-1))
134
+ )
135
+ )
136
+ end
137
+ private_class_method :coefficient_db_per_m
138
+ end
139
+ end
@@ -0,0 +1,123 @@
1
+ # frozen_string_literal: true
2
+
3
+ module HornAcoustics
4
+ # Equal-tempered frequencies of multi-chime horn notes (ISO 16:1975).
5
+ module ChordFrequencies
6
+ # Pitch class in semitones from C: C=0, D=2, E=4, F=5, G=7, A=9, B=11.
7
+ PITCH_CLASS = {
8
+ "C" => 0,
9
+ "D" => 2,
10
+ "E" => 4,
11
+ "F" => 5,
12
+ "G" => 7,
13
+ "A" => 9,
14
+ "B" => 11
15
+ }.freeze
16
+
17
+ NOTE_RE = /\A\s*([A-Ga-g])([#b]?)(-?\d+)\s*\z/.freeze
18
+
19
+ module_function
20
+
21
+ # Frequencies of named notes in twelve-tone equal temperament with
22
+ # the standard concert pitch A4 = 440 Hz given by ISO 16:1975. Each
23
+ # semitone is a frequency ratio of 2^(1/12), so a note n semitones
24
+ # above A4 has frequency
25
+ #
26
+ # f = 440 × 2^(n/12)
27
+ #
28
+ # Note names are scientific pitch notation: a letter A–G, an
29
+ # optional accidental `#` (sharp) or `b` (flat), and an octave
30
+ # number (for example `"A4"`, `"F#4"`, `"Db5"`). Middle C is `"C4"`.
31
+ # Octave numbers may be zero or negative (`"C0"`, `"B-1"`) in the
32
+ # usual way.
33
+ #
34
+ # No instrument-specific tuning tables or measured horn spectra are
35
+ # used; the result is exactly the equal-tempered frequency of the
36
+ # named pitch.
37
+ #
38
+ # @param notes [String, Array<String>] note names, or a single
39
+ # string of notes separated by spaces or commas (for example
40
+ # `"D4 F#4 A4"`).
41
+ # @param a4 [Numeric] frequency of A4, in hertz. Defaults to 440,
42
+ # the value specified in ISO 16:1975. Other values are provided
43
+ # only so that a known historical pitch standard can be
44
+ # substituted; they are not used unless you pass them.
45
+ #
46
+ # @return [Hash{String=>Float}] frequencies in hertz, keyed by the
47
+ # supplied note names, in input order.
48
+ #
49
+ # @raise [ArgumentError] if +a4+ is not a single positive number, a
50
+ # numeric value is passed in place of note names, a note name
51
+ # cannot be parsed, or +notes+ is empty.
52
+ #
53
+ # @example A common three-chime train-horn major triad
54
+ # HornAcoustics.chord_frequencies(["D4", "F#4", "A4"])
55
+ #
56
+ # @example A4 is 440 Hz; the A an octave above is 880 Hz
57
+ # HornAcoustics.chord_frequencies(["A4", "A5"])
58
+ #
59
+ # @see HornAcoustics.doppler_shift
60
+ # @see https://www.iso.org/standard/3601.html ISO 16:1975
61
+ #
62
+ # @reference International Organization for Standardization (1975).
63
+ # *Acoustics — Standard tuning frequency (Standard musical pitch).*
64
+ # ISO 16:1975. The twelve-tone equal-tempered scale with a common
65
+ # ratio of 2^(1/12) is the scale that ISO 16 anchors at A4 = 440 Hz.
66
+ def chord_frequencies(notes, a4: 440)
67
+ Util.check_positive(a4, "a4")
68
+ unless a4.is_a?(Numeric) && !a4.is_a?(Array)
69
+ raise ArgumentError, "a4 must be a single positive number."
70
+ end
71
+ if notes.is_a?(Numeric)
72
+ raise ArgumentError,
73
+ 'notes must be note names such as "A4" or "F#4", not numbers.'
74
+ end
75
+
76
+ names = normalize_notes(notes)
77
+ if names.empty?
78
+ raise ArgumentError, "notes must contain at least one note name."
79
+ end
80
+
81
+ names.each_with_object({}) do |note, out|
82
+ out[note] = a4 * (2**(semitones_from_a4(note) / 12.0))
83
+ end
84
+ end
85
+
86
+ # @api private
87
+ def normalize_notes(notes)
88
+ list =
89
+ if notes.is_a?(Array)
90
+ notes.map(&:to_s)
91
+ else
92
+ text = notes.to_s
93
+ if text.match?(/[[:space:],]/)
94
+ text.split(/[[:space:],]+/).reject(&:empty?)
95
+ else
96
+ [text]
97
+ end
98
+ end
99
+ list
100
+ end
101
+ private_class_method :normalize_notes
102
+
103
+ # Semitones from A4, using MIDI numbering with C4 = 60, A4 = 69.
104
+ # @api private
105
+ def semitones_from_a4(note)
106
+ match = NOTE_RE.match(note)
107
+ unless match
108
+ raise ArgumentError,
109
+ "Cannot parse note name \"#{note}\". Use scientific pitch " \
110
+ "notation such as \"A4\", \"F#4\", or \"Db5\"."
111
+ end
112
+ letter = match[1].upcase
113
+ accidental = match[2]
114
+ octave = Integer(match[3])
115
+ pc = PITCH_CLASS[letter]
116
+ pc += 1 if accidental == "#"
117
+ pc -= 1 if accidental == "b"
118
+ midi = (octave + 1) * 12 + pc
119
+ midi - 69
120
+ end
121
+ private_class_method :semitones_from_a4
122
+ end
123
+ end
@@ -0,0 +1,109 @@
1
+ # frozen_string_literal: true
2
+
3
+ module HornAcoustics
4
+ # Classical Doppler shift for a moving source or observer.
5
+ module DopplerShift
6
+ module_function
7
+
8
+ # Observed frequency of a tone when the source and/or the observer
9
+ # move along the line that joins them, in a still medium. The
10
+ # classical (non-relativistic) Doppler formula is
11
+ #
12
+ # f = f₀ (c + v_o) / (c − v_s)
13
+ #
14
+ # where v_o is the component of the observer's speed toward the
15
+ # source, v_s is the component of the source's speed toward the
16
+ # observer, and c is the speed of sound. The sign convention is the
17
+ # usual textbook one: motion of either party toward the other raises
18
+ # the observed frequency.
19
+ #
20
+ # The speed of sound is obtained from air temperature by
21
+ # {HornAcoustics.speed_of_sound}, which uses the sea-level standard
22
+ # atmosphere of ISO 2533:1975 (c = 340.294 √(T/T_n) m/s, T_n = 288.15 K).
23
+ # Motions not along the line of sight are not treated; pass the
24
+ # line-of-sight components as the speeds.
25
+ #
26
+ # @param frequency [Numeric, Array<Numeric>] source (emitted)
27
+ # frequency, in hertz. Must be positive.
28
+ # @param source_speed [Numeric, Array<Numeric>] speed of the source,
29
+ # in metres per second. Must be non-negative. Defaults to 0
30
+ # (stationary source).
31
+ # @param observer_speed [Numeric, Array<Numeric>] speed of the
32
+ # observer, in metres per second. Must be non-negative. Defaults
33
+ # to 0 (stationary observer).
34
+ # @param temperature [Numeric, Array<Numeric>] air temperature in
35
+ # degrees Celsius, used to obtain the speed of sound. Defaults to 20.
36
+ # @param source_towards_observer [Boolean, Array<Boolean>] if +true+
37
+ # (the default), the source moves toward the observer; if +false+,
38
+ # it moves away.
39
+ # @param observer_towards_source [Boolean, Array<Boolean>] if +true+
40
+ # (the default), the observer moves toward the source; if +false+,
41
+ # it moves away.
42
+ #
43
+ # @return [Float, Array<Float>] observed frequency, in hertz.
44
+ #
45
+ # @raise [ArgumentError] if a frequency is not positive, a speed is
46
+ # negative, a direction flag is not a boolean, or the line-of-sight
47
+ # source speed toward the observer is at or above the speed of sound
48
+ # (the classical formula does not apply at or above Mach 1).
49
+ #
50
+ # @example Stationary 440 Hz source and observer: no shift
51
+ # HornAcoustics.doppler_shift(440)
52
+ #
53
+ # @example Train-horn tone approaching a wayside observer at 30 m/s (~67 mph)
54
+ # HornAcoustics.doppler_shift(440, source_speed: 30, source_towards_observer: true)
55
+ #
56
+ # @example The same source receding
57
+ # HornAcoustics.doppler_shift(440, source_speed: 30, source_towards_observer: false)
58
+ #
59
+ # @see HornAcoustics.speed_of_sound
60
+ # @see HornAcoustics.chord_frequencies
61
+ #
62
+ # @reference The classical Doppler formula for a moving source and
63
+ # observer in a still medium, in the form f = f₀ (c + v_o) / (c − v_s)
64
+ # with the sign convention above, is the standard result of linear
65
+ # acoustics; see e.g. Morse, P. M. and Ingard, K. U. (1968),
66
+ # *Theoretical Acoustics*, McGraw-Hill, section 11.1. The speed of
67
+ # sound as a function of temperature follows ISO 2533:1975; see
68
+ # {HornAcoustics.speed_of_sound}.
69
+ def doppler_shift(frequency, source_speed: 0, observer_speed: 0,
70
+ temperature: 20, source_towards_observer: true,
71
+ observer_towards_source: true)
72
+ Util.check_positive_each(frequency, "frequency")
73
+ Util.check_positive_each(source_speed, "source_speed", strict: false)
74
+ Util.check_positive_each(observer_speed, "observer_speed", strict: false)
75
+ Util.check_numeric_each(temperature, "temperature")
76
+
77
+ freqs, v_src, v_obs, temps, src_towards, obs_towards = Util.broadcast(
78
+ frequency, source_speed, observer_speed, temperature,
79
+ source_towards_observer, observer_towards_source
80
+ )
81
+
82
+ unless src_towards.all? { |v| v == true || v == false }
83
+ raise ArgumentError, "source_towards_observer must be true or false."
84
+ end
85
+ unless obs_towards.all? { |v| v == true || v == false }
86
+ raise ArgumentError, "observer_towards_source must be true or false."
87
+ end
88
+
89
+ observed = freqs.zip(v_src, v_obs, temps, src_towards, obs_towards).map do |f0, vs, vo, t_c, st, ot|
90
+ c_sound = SpeedOfSound.speed_of_sound(t_c)
91
+ v_s = st ? vs : -vs
92
+ v_o = ot ? vo : -vo
93
+ denom = c_sound - v_s
94
+ if denom <= 0
95
+ raise ArgumentError,
96
+ "The line-of-sight source speed toward the observer must be " \
97
+ "smaller than the speed of sound (the classical formula does " \
98
+ "not apply at or above Mach 1)."
99
+ end
100
+ f0 * (c_sound + v_o) / denom
101
+ end
102
+ Util.maybe_scalar(
103
+ observed,
104
+ frequency, source_speed, observer_speed, temperature,
105
+ source_towards_observer, observer_towards_source
106
+ )
107
+ end
108
+ end
109
+ end
@@ -0,0 +1,166 @@
1
+ # frozen_string_literal: true
2
+
3
+ module HornAcoustics
4
+ # One row of a 49 CFR 222.21 (b)(2)–(b)(3) sounding window.
5
+ #
6
+ # @!attribute speed
7
+ # @return [Numeric] the input speed, in {#speed_unit}
8
+ # @!attribute speed_unit
9
+ # @return [String] `"mph"`, `"km/h"`, or `"m/s"`
10
+ # @!attribute start_distance_min
11
+ # @return [Float] distance from the crossing at which sounding must
12
+ # have begun (the 15-second point, or 1,320 feet if the cap in
13
+ # (b)(3) is tighter), in {#distance_unit}
14
+ # @!attribute start_distance_max
15
+ # @return [Float] farthest distance from the crossing at which
16
+ # sounding may begin (the 20-second point, capped at 1,320 feet
17
+ # when (b)(3) applies), in {#distance_unit}
18
+ # @!attribute distance_unit
19
+ # @return [String] `"ft"`, `"m"`, or `"mi"`
20
+ # @!attribute start_time_min
21
+ # @return [Float] seconds before entering the crossing that
22
+ # correspond to {#start_distance_min}
23
+ # @!attribute start_time_max
24
+ # @return [Float] seconds before entering the crossing that
25
+ # correspond to {#start_distance_max}
26
+ # @!attribute quarter_mile_cap_applied
27
+ # @return [Boolean] +true+ when speed is greater than 60 mph and the
28
+ # 1,320-foot cap of (b)(3) has limited the window
29
+ Window = Struct.new(
30
+ :speed,
31
+ :speed_unit,
32
+ :start_distance_min,
33
+ :start_distance_max,
34
+ :distance_unit,
35
+ :start_time_min,
36
+ :start_time_max,
37
+ :quarter_mile_cap_applied,
38
+ keyword_init: true
39
+ )
40
+
41
+ # Grade-crossing locomotive-horn sounding window (49 CFR 222.21).
42
+ module HornWindow
43
+ # International mile, in feet (the regulation writes 1,320 feet).
44
+ FT_PER_MI = 5280.0
45
+ # International foot, in metres (0.3048 m exactly).
46
+ M_PER_FT = 0.3048
47
+ # Quarter-mile cap of 49 CFR 222.21 (b)(3), in feet.
48
+ CAP_FT = 1320.0
49
+ # Speed above which the (b)(3) cap applies, in miles per hour.
50
+ CAP_SPEED_MPH = 60.0
51
+ # International mile in kilometres (exactly 1.609344).
52
+ KM_PER_MI = 1.609344
53
+
54
+ module_function
55
+
56
+ # Distances and times at which a locomotive horn must begin to be
57
+ # sounded when approaching a public highway-rail grade crossing,
58
+ # taken only from 49 CFR 222.21 (b)(2) and (b)(3) (current text of
59
+ # the U.S. *Electronic Code of Federal Regulations*).
60
+ #
61
+ # Paragraph (b)(2) requires that the horn begin to be sounded at
62
+ # least 15 seconds, but no more than 20 seconds, before the
63
+ # locomotive enters the crossing. Paragraph (b)(3) adds that trains
64
+ # traveling at speeds in excess of 60 mph shall not begin sounding
65
+ # the horn more than one-quarter mile (1,320 feet) in advance of the
66
+ # nearest public highway-rail grade crossing, even if that makes the
67
+ # advance warning shorter than 15 seconds. At 60 mph, 15 seconds of
68
+ # travel is exactly one-quarter mile, so the distance cap first
69
+ # binds only above 60 mph.
70
+ #
71
+ # The following provisions of the same section are documented here
72
+ # but are not implemented: the good-faith allowance in (b)(2) to
73
+ # begin sounding as early as 25 seconds when the engineer cannot
74
+ # precisely estimate arrival; the Chicago-Region exception in
75
+ # paragraph (c); and the close-proximity / stopped-train exceptions
76
+ # in paragraph (d). The sounding pattern of two long, one short and
77
+ # one long blasts in paragraph (a) is also outside the scope of this
78
+ # helper.
79
+ #
80
+ # @param speed [Numeric, Array<Numeric>] train speed. Must be
81
+ # positive. A list of speeds returns one {HornAcoustics::Window}
82
+ # per speed.
83
+ # @param speed_unit [String] unit of +speed+: `"mph"` (the unit used
84
+ # in the regulation), `"km/h"`, or `"m/s"`. Defaults to `"mph"`.
85
+ # @param distance_unit [String] unit of the returned start
86
+ # distances: `"ft"` (the regulation states the cap as 1,320 feet),
87
+ # `"m"`, or `"mi"`. Defaults to `"ft"`.
88
+ #
89
+ # @return [HornAcoustics::Window, Array<HornAcoustics::Window>] one
90
+ # window when +speed+ is a single number, otherwise one per speed.
91
+ #
92
+ # @raise [ArgumentError] if a speed is not positive, or a unit is
93
+ # not one of the values listed above.
94
+ #
95
+ # @example At 45 mph the 15–20 s window is shorter than a quarter mile
96
+ # HornAcoustics.horn_window(45)
97
+ #
98
+ # @example At 60 mph, 15 s is exactly a quarter mile; the cap is not yet applied
99
+ # HornAcoustics.horn_window(60)
100
+ #
101
+ # @example Above 60 mph the 1,320 ft cap binds and the warning can be under 15 s
102
+ # HornAcoustics.horn_window(80)
103
+ #
104
+ # @see https://www.ecfr.gov/current/title-49/section-222.21 49 CFR 222.21
105
+ #
106
+ # @reference *When must a locomotive horn be used?*, 49 CFR 222.21,
107
+ # https://www.ecfr.gov/current/title-49/section-222.21
108
+ # The quarter-mile cap is the 1,320 feet stated in paragraph
109
+ # (b)(3). Unit conversions use the international foot (0.3048 m
110
+ # exactly) and the international mile (5,280 feet).
111
+ def horn_window(speed, speed_unit: "mph", distance_unit: "ft")
112
+ unless %w[mph km/h m/s].include?(speed_unit)
113
+ raise ArgumentError, 'speed_unit must be "mph", "km/h", or "m/s".'
114
+ end
115
+ unless %w[ft m mi].include?(distance_unit)
116
+ raise ArgumentError, 'distance_unit must be "ft", "m", or "mi".'
117
+ end
118
+ Util.check_positive_each(speed, "speed")
119
+
120
+ rows = Util.list(speed).map do |v|
121
+ speed_mph = to_mph(v, speed_unit)
122
+ # Distances travelled in 15 s and 20 s, in feet. 1 mph = 5280/3600 ft/s.
123
+ ft_per_s = speed_mph * FT_PER_MI / 3600.0
124
+ d15_ft = ft_per_s * 15.0
125
+ d20_ft = ft_per_s * 20.0
126
+
127
+ cap_applies = speed_mph > CAP_SPEED_MPH
128
+ start_max_ft = cap_applies ? [d20_ft, CAP_FT].min : d20_ft
129
+ start_min_ft = cap_applies ? [d15_ft, CAP_FT].min : d15_ft
130
+ cap_applied = cap_applies && (d15_ft > CAP_FT || d20_ft > CAP_FT)
131
+
132
+ Window.new(
133
+ speed: v,
134
+ speed_unit: speed_unit,
135
+ start_distance_min: to_distance_unit(start_min_ft, distance_unit),
136
+ start_distance_max: to_distance_unit(start_max_ft, distance_unit),
137
+ distance_unit: distance_unit,
138
+ start_time_min: start_min_ft / ft_per_s,
139
+ start_time_max: start_max_ft / ft_per_s,
140
+ quarter_mile_cap_applied: cap_applied
141
+ )
142
+ end
143
+ speed.is_a?(Array) ? rows : rows.first
144
+ end
145
+
146
+ # @api private
147
+ def to_mph(speed, speed_unit)
148
+ case speed_unit
149
+ when "mph" then speed.to_f
150
+ when "km/h" then speed.to_f / KM_PER_MI
151
+ when "m/s" then speed.to_f / (KM_PER_MI * 1000.0 / 3600.0)
152
+ end
153
+ end
154
+ private_class_method :to_mph
155
+
156
+ # @api private
157
+ def to_distance_unit(feet, distance_unit)
158
+ case distance_unit
159
+ when "ft" then feet
160
+ when "m" then feet * M_PER_FT
161
+ when "mi" then feet / FT_PER_MI
162
+ end
163
+ end
164
+ private_class_method :to_distance_unit
165
+ end
166
+ end
@@ -0,0 +1,51 @@
1
+ # frozen_string_literal: true
2
+
3
+ module HornAcoustics
4
+ # Speed of sound in air from temperature (ISO 2533:1975).
5
+ module SpeedOfSound
6
+ # Sea-level standard speed of sound, in m/s (ISO 2533:1975).
7
+ AN = 340.294
8
+ # Sea-level standard temperature, in kelvin (ISO 2533:1975).
9
+ TN = 288.15
10
+
11
+ module_function
12
+
13
+ # Speed of sound in dry air at ambient temperature after the
14
+ # International Standard Atmosphere, ISO 2533:1975. At the standard
15
+ # sea-level temperature T_n = 288.15 K (15 °C) the standard gives
16
+ # a_n = 340.294 m/s. Under the ideal-gas square-root law used by
17
+ # that standard,
18
+ #
19
+ # c = 340.294 √(T / T_n)
20
+ #
21
+ # with T in kelvin. Humidity and static-pressure corrections are
22
+ # not applied; only the temperature dependence of the standard
23
+ # atmosphere is used.
24
+ #
25
+ # @param temperature [Numeric, Array<Numeric>] air temperature, in
26
+ # degrees Celsius. Defaults to 20.
27
+ #
28
+ # @return [Float, Array<Float>] speed of sound, in metres per second.
29
+ #
30
+ # @raise [ArgumentError] if temperature is at or below absolute zero.
31
+ #
32
+ # @example
33
+ # HornAcoustics.speed_of_sound(15) #=> 340.294
34
+ # HornAcoustics.speed_of_sound([0, 15, 20, 30])
35
+ #
36
+ # @see HornAcoustics.doppler_shift
37
+ # @see https://www.iso.org/standard/7472.html ISO 2533:1975
38
+ #
39
+ # @reference International Organization for Standardization (1975).
40
+ # *Standard Atmosphere.* ISO 2533:1975. Sea-level standard speed
41
+ # of sound a_n = 340.294 m/s at T_n = 288.15 K.
42
+ def speed_of_sound(temperature = 20)
43
+ Util.check_numeric_each(temperature, "temperature")
44
+ values = Util.list(temperature).map do |t_c|
45
+ t_k = Util.to_kelvin(t_c)
46
+ AN * Math.sqrt(t_k / TN)
47
+ end
48
+ Util.maybe_scalar(values, temperature)
49
+ end
50
+ end
51
+ end
@@ -0,0 +1,115 @@
1
+ # frozen_string_literal: true
2
+
3
+ module HornAcoustics
4
+ # Sound pressure level versus distance (ISO 9613-2:1996, optional ISO 9613-1).
5
+ module SplAtDistance
6
+ module_function
7
+
8
+ # Change in sound pressure level with distance for a point source in
9
+ # a free field, from the inverse-square (spherical spreading) law,
10
+ # with optional atmospheric absorption.
11
+ #
12
+ # Geometrical divergence between two distances follows ISO 9613-2:1996,
13
+ # clause 7.1, equation (7): the attenuation due to spherical spreading
14
+ # is A_div = 20 log₁₀(d/d₀) + 11 dB with d₀ = 1 m. The constant 11 dB
15
+ # (= 10 log₁₀(4π)) converts a sound power level to a sound pressure
16
+ # level at 1 m and cancels when the change between two receiver
17
+ # distances is taken, leaving the inverse-square ratio
18
+ #
19
+ # L(d) = L(d_ref) − 20 log₁₀(d / d_ref)
20
+ #
21
+ # When +absorption+ is +true+, the pure-tone atmospheric absorption
22
+ # of ISO 9613-1:1993 (see {HornAcoustics.atmospheric_absorption}) is
23
+ # added over the path between +distance_ref+ and +distance+. This is
24
+ # the same term as ISO 9613-2:1996, equation (8), A_atm = α d with
25
+ # α in decibels per metre, applied to the path difference:
26
+ #
27
+ # L(d) = L(d_ref) − 20 log₁₀(d / d_ref) − α (d − d_ref)
28
+ #
29
+ # Distances are in metres. The method does not include ground effect,
30
+ # screening, or directivity (the remaining terms of ISO 9613-2); only
31
+ # spherical spreading and, optionally, atmospheric absorption are
32
+ # applied.
33
+ #
34
+ # @param spl_ref [Numeric, Array<Numeric>] sound pressure level at
35
+ # +distance_ref+, in decibels.
36
+ # @param distance [Numeric, Array<Numeric>] receiver distance from
37
+ # the source, in metres. Must be positive.
38
+ # @param distance_ref [Numeric, Array<Numeric>] reference distance at
39
+ # which +spl_ref+ is given, in metres. Defaults to 1.
40
+ # @param absorption [Boolean] if +true+, subtract atmospheric
41
+ # absorption from ISO 9613-1:1993 over the path between
42
+ # +distance_ref+ and +distance+. Defaults to +false+. Must be a
43
+ # single boolean.
44
+ # @param frequency [Numeric, Array<Numeric>, nil] sound frequency in
45
+ # hertz, required when +absorption+ is +true+.
46
+ # @param temperature [Numeric, Array<Numeric>] air temperature in
47
+ # degrees Celsius, passed to {HornAcoustics.atmospheric_absorption}
48
+ # when +absorption+ is +true+. Defaults to 20.
49
+ # @param humidity [Numeric, Array<Numeric>] relative humidity in
50
+ # percent, passed to {HornAcoustics.atmospheric_absorption} when
51
+ # +absorption+ is +true+. Defaults to 50.
52
+ # @param pressure [Numeric, Array<Numeric>] ambient pressure in
53
+ # kilopascals, passed to {HornAcoustics.atmospheric_absorption}
54
+ # when +absorption+ is +true+. Defaults to 101.325.
55
+ #
56
+ # @return [Float, Array<Float>] sound pressure level(s), in
57
+ # decibels, at +distance+.
58
+ #
59
+ # @raise [ArgumentError] if a distance is not positive, +absorption+
60
+ # is not a single true or false, or +frequency+ is omitted when
61
+ # +absorption+ is +true+.
62
+ #
63
+ # @example Inverse-square law only: doubling the distance lowers the level by 20 log₁₀(2) ≈ 6.02 dB
64
+ # HornAcoustics.spl_at_distance(100, 2, distance_ref: 1)
65
+ #
66
+ # @example A 1 kHz tone, including ISO 9613-1 atmospheric absorption
67
+ # HornAcoustics.spl_at_distance(110, 100, distance_ref: 1, absorption: true, frequency: 1000)
68
+ #
69
+ # @see HornAcoustics.atmospheric_absorption
70
+ # @see https://www.iso.org/standard/20649.html ISO 9613-2:1996
71
+ #
72
+ # @reference International Organization for Standardization (1996).
73
+ # *Acoustics — Attenuation of sound during propagation outdoors —
74
+ # Part 2: General method of calculation.* ISO 9613-2:1996, clause 7.1.
75
+ #
76
+ # International Organization for Standardization (1993).
77
+ # *Acoustics — Attenuation of sound during propagation outdoors —
78
+ # Part 1: Calculation of the absorption of sound by the atmosphere.*
79
+ # ISO 9613-1:1993.
80
+ def spl_at_distance(spl_ref, distance, distance_ref: 1, absorption: false,
81
+ frequency: nil, temperature: 20, humidity: 50,
82
+ pressure: 101.325)
83
+ Util.check_numeric_each(spl_ref, "spl_ref")
84
+ Util.check_positive_each(distance, "distance")
85
+ Util.check_positive_each(distance_ref, "distance_ref")
86
+ unless absorption == true || absorption == false
87
+ raise ArgumentError, "absorption must be a single true or false."
88
+ end
89
+
90
+ refs, dists, drefs = Util.broadcast(spl_ref, distance, distance_ref)
91
+ levels = refs.zip(dists, drefs).map do |l_ref, d, d0|
92
+ l_ref - 20.0 * Math.log10(d / d0)
93
+ end
94
+
95
+ if absorption
96
+ if frequency.nil?
97
+ raise ArgumentError, "frequency must be supplied when absorption = true."
98
+ end
99
+ alphas = AtmosphericAbsorption.atmospheric_absorption(
100
+ frequency,
101
+ temperature: temperature,
102
+ humidity: humidity,
103
+ pressure: pressure,
104
+ unit: "dB/m"
105
+ )
106
+ alpha_list, dist_list, dref_list = Util.broadcast(alphas, dists, drefs)
107
+ levels = levels.zip(alpha_list, dist_list, dref_list).map do |level, alpha, d, d0|
108
+ level - alpha * (d - d0)
109
+ end
110
+ end
111
+
112
+ Util.maybe_scalar(levels, spl_ref, distance, distance_ref, frequency)
113
+ end
114
+ end
115
+ end
@@ -0,0 +1,81 @@
1
+ # frozen_string_literal: true
2
+
3
+ module HornAcoustics
4
+ # Shared input checks and Kelvin conversion. Not part of the public API.
5
+ # @api private
6
+ module Util
7
+ module_function
8
+
9
+ # Recycle Ruby values the way R recycles vectors: a bare Numeric or
10
+ # one-element list is expanded to +length+, otherwise the list must
11
+ # already be that long or a multiple that tiles evenly.
12
+ def list(value)
13
+ value.is_a?(Array) ? value : [value]
14
+ end
15
+
16
+ def broadcast(*values)
17
+ lists = values.map { |v| list(v) }
18
+ length = lists.map(&:length).max
19
+ lists.map { |items| recycle(items, length) }
20
+ end
21
+
22
+ def recycle(items, length)
23
+ return items if items.length == length
24
+ if length % items.length != 0
25
+ raise ArgumentError,
26
+ "input lengths (#{items.length} and #{length}) are not compatible"
27
+ end
28
+ items * (length / items.length)
29
+ end
30
+
31
+ def check_numeric(value, name, finite: true)
32
+ unless value.is_a?(Numeric)
33
+ raise ArgumentError, "#{name} must be numeric."
34
+ end
35
+ if finite && !value.finite?
36
+ raise ArgumentError, "#{name} must be finite."
37
+ end
38
+ value
39
+ end
40
+
41
+ def check_positive(value, name, strict: true)
42
+ check_numeric(value, name)
43
+ if strict && value <= 0
44
+ raise ArgumentError, "#{name} must be greater than 0."
45
+ end
46
+ if !strict && value < 0
47
+ raise ArgumentError, "#{name} must be greater than or equal to 0."
48
+ end
49
+ value
50
+ end
51
+
52
+ def check_numeric_each(values, name, finite: true)
53
+ list(values).each { |v| check_numeric(v, name, finite: finite) }
54
+ values
55
+ end
56
+
57
+ def check_positive_each(values, name, strict: true)
58
+ list(values).each { |v| check_positive(v, name, strict: strict) }
59
+ values
60
+ end
61
+
62
+ # Convert degrees Celsius to kelvin. ISO 9613-1 and ISO 2533 use T in K.
63
+ def to_kelvin(temperature_c)
64
+ check_numeric(temperature_c, "temperature")
65
+ kelvin = temperature_c + 273.15
66
+ if kelvin <= 0
67
+ raise ArgumentError,
68
+ "temperature must be greater than -273.15 degrees Celsius."
69
+ end
70
+ kelvin
71
+ end
72
+
73
+ def maybe_scalar(values, *originals)
74
+ if originals.any? { |item| item.is_a?(Array) } || values.length != 1
75
+ values
76
+ else
77
+ values.first
78
+ end
79
+ end
80
+ end
81
+ end
@@ -0,0 +1,6 @@
1
+ # frozen_string_literal: true
2
+
3
+ module HornAcoustics
4
+ # Library version. Matches the companion R package hornacoustics 0.1.0.
5
+ VERSION = "0.1.0"
6
+ end
@@ -0,0 +1,64 @@
1
+ # frozen_string_literal: true
2
+
3
+ require_relative "horn_acoustics/version"
4
+ require_relative "horn_acoustics/util"
5
+ require_relative "horn_acoustics/atmospheric_absorption"
6
+ require_relative "horn_acoustics/speed_of_sound"
7
+ require_relative "horn_acoustics/doppler_shift"
8
+ require_relative "horn_acoustics/horn_window"
9
+ require_relative "horn_acoustics/chord_frequencies"
10
+ require_relative "horn_acoustics/spl_at_distance"
11
+
12
+ # Outdoor acoustics helpers used with train horns: how the sound-pressure
13
+ # level of a point source changes with distance, how much air absorbs a
14
+ # tone, the Doppler shift of a moving source or observer, the sounding
15
+ # window required at a U.S. public highway-rail grade crossing, and the
16
+ # equal-tempered frequencies of a multi-chime horn.
17
+ #
18
+ # Every formula is taken from a published standard or regulation:
19
+ #
20
+ # * inverse-square (spherical) spreading: ISO 9613-2:1996, clause 7.1
21
+ # * atmospheric absorption: ISO 9613-1:1993, equations (3)–(5) and Annex B
22
+ # * speed of sound versus temperature: ISO 2533:1975
23
+ # * classical Doppler formula for a source and observer in a still medium
24
+ # * locomotive-horn sounding window: 49 CFR 222.21 (b)(2)–(b)(3) only
25
+ # * A4 = 440 Hz, twelve-tone equal temperament: ISO 16:1975
26
+ #
27
+ # The library does not invent spectra, empirical horn data, or fitted
28
+ # constants.
29
+ #
30
+ # @see https://hornguns.com/
31
+ # @author Horn Guns <info@hornguns.com>
32
+ module HornAcoustics
33
+ module_function
34
+
35
+ # @see AtmosphericAbsorption.atmospheric_absorption
36
+ def atmospheric_absorption(*args, **kwargs)
37
+ AtmosphericAbsorption.atmospheric_absorption(*args, **kwargs)
38
+ end
39
+
40
+ # @see SpeedOfSound.speed_of_sound
41
+ def speed_of_sound(*args, **kwargs)
42
+ SpeedOfSound.speed_of_sound(*args, **kwargs)
43
+ end
44
+
45
+ # @see DopplerShift.doppler_shift
46
+ def doppler_shift(*args, **kwargs)
47
+ DopplerShift.doppler_shift(*args, **kwargs)
48
+ end
49
+
50
+ # @see HornWindow.horn_window
51
+ def horn_window(*args, **kwargs)
52
+ HornWindow.horn_window(*args, **kwargs)
53
+ end
54
+
55
+ # @see ChordFrequencies.chord_frequencies
56
+ def chord_frequencies(*args, **kwargs)
57
+ ChordFrequencies.chord_frequencies(*args, **kwargs)
58
+ end
59
+
60
+ # @see SplAtDistance.spl_at_distance
61
+ def spl_at_distance(*args, **kwargs)
62
+ SplAtDistance.spl_at_distance(*args, **kwargs)
63
+ end
64
+ end
metadata ADDED
@@ -0,0 +1,62 @@
1
+ --- !ruby/object:Gem::Specification
2
+ name: horn_acoustics
3
+ version: !ruby/object:Gem::Version
4
+ version: 0.1.0
5
+ platform: ruby
6
+ authors:
7
+ - Horn Guns
8
+ bindir: bin
9
+ cert_chain: []
10
+ date: 1980-01-02 00:00:00.000000000 Z
11
+ dependencies: []
12
+ description: |
13
+ Calculate outdoor sound-pressure-level change with distance from the
14
+ free-field inverse-square law (geometrical divergence in ISO
15
+ 9613-2:1996) and, optionally, atmospheric absorption after ISO
16
+ 9613-1:1993. Compute the classical Doppler-shifted frequency for a
17
+ moving source or observer (speed of sound from air temperature after
18
+ ISO 2533:1975), the locomotive-horn sounding window at public
19
+ highway-rail grade crossings given in 49 CFR 222.21 (b)(2)-(b)(3),
20
+ and equal-tempered frequencies of multi-chime horn notes with A4 at
21
+ 440 Hz (ISO 16:1975).
22
+ email:
23
+ - info@hornguns.com
24
+ executables: []
25
+ extensions: []
26
+ extra_rdoc_files: []
27
+ files:
28
+ - LICENSE
29
+ - README.md
30
+ - lib/horn_acoustics.rb
31
+ - lib/horn_acoustics/atmospheric_absorption.rb
32
+ - lib/horn_acoustics/chord_frequencies.rb
33
+ - lib/horn_acoustics/doppler_shift.rb
34
+ - lib/horn_acoustics/horn_window.rb
35
+ - lib/horn_acoustics/speed_of_sound.rb
36
+ - lib/horn_acoustics/spl_at_distance.rb
37
+ - lib/horn_acoustics/util.rb
38
+ - lib/horn_acoustics/version.rb
39
+ homepage: https://hornguns.com/
40
+ licenses:
41
+ - MIT
42
+ metadata:
43
+ homepage_uri: https://hornguns.com/
44
+ documentation_uri: https://www.rubydoc.info/gems/horn_acoustics
45
+ rdoc_options: []
46
+ require_paths:
47
+ - lib
48
+ required_ruby_version: !ruby/object:Gem::Requirement
49
+ requirements:
50
+ - - ">="
51
+ - !ruby/object:Gem::Version
52
+ version: '2.7'
53
+ required_rubygems_version: !ruby/object:Gem::Requirement
54
+ requirements:
55
+ - - ">="
56
+ - !ruby/object:Gem::Version
57
+ version: '0'
58
+ requirements: []
59
+ rubygems_version: 3.6.9
60
+ specification_version: 4
61
+ summary: Acoustic calculations for train horns from published standards.
62
+ test_files: []