honeybee-openstudio 2.10.1 → 2.11.1
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +4 -4
- data/.gitignore +1 -0
- data/Gemfile +1 -1
- data/honeybee-openstudio.gemspec +2 -2
- data/lib/files/reopt_assumptions.json +146 -0
- data/lib/files/urbanopt_Gemfile +4 -4
- data/lib/honeybee/_defaults/model.json +163 -163
- data/lib/honeybee/_defaults/simulation-parameter.json +1 -1
- data/lib/measures/from_honeybee_model/measure.rb +23 -0
- data/lib/to_openstudio/hvac/Model.hvac.rb +124 -166
- data/lib/to_openstudio/hvac/template.rb +10 -2
- data/lib/to_openstudio/model.rb +64 -4
- data/lib/to_openstudio/schedule/fixed_interval.rb +146 -30
- data/lib/to_openstudio/schedule/ruleset.rb +2 -1
- data/lib/to_openstudio/simulation/parameter_model.rb +1 -1
- metadata +5 -4
@@ -60,6 +60,19 @@ class FromHoneybeeModel < OpenStudio::Measure::ModelMeasure
|
|
60
60
|
model_json.setDisplayName('Path to the Honeybee Model JSON file')
|
61
61
|
args << model_json
|
62
62
|
|
63
|
+
# Make an argument for schedule csv dir
|
64
|
+
schedule_csv_dir = OpenStudio::Measure::OSArgument.makeStringArgument('schedule_csv_dir', false)
|
65
|
+
schedule_csv_dir.setDisplayName('Directory for exported CSV Schedules')
|
66
|
+
schedule_csv_dir.setDescription('If set, Fixed Interval Schedules will be translated to CSV Schedules in this directory')
|
67
|
+
schedule_csv_dir.setDefaultValue('')
|
68
|
+
args << schedule_csv_dir
|
69
|
+
|
70
|
+
# Make an argument for include datetimes
|
71
|
+
include_datetimes = OpenStudio::Measure::OSArgument.makeBoolArgument('include_datetimes', false)
|
72
|
+
include_datetimes.setDisplayName('Include date time column in exported CSV Schedules')
|
73
|
+
include_datetimes.setDefaultValue(false)
|
74
|
+
args << include_datetimes
|
75
|
+
|
63
76
|
return args
|
64
77
|
end
|
65
78
|
|
@@ -72,6 +85,8 @@ class FromHoneybeeModel < OpenStudio::Measure::ModelMeasure
|
|
72
85
|
end
|
73
86
|
|
74
87
|
model_json = runner.getStringArgumentValue('model_json', user_arguments)
|
88
|
+
schedule_csv_dir = runner.getStringArgumentValue('schedule_csv_dir', user_arguments)
|
89
|
+
include_datetimes = runner.getBoolArgumentValue('include_datetimes', user_arguments)
|
75
90
|
|
76
91
|
if !File.exist?(model_json)
|
77
92
|
runner.registerError("Cannot find file '#{model_json}'")
|
@@ -80,6 +95,14 @@ class FromHoneybeeModel < OpenStudio::Measure::ModelMeasure
|
|
80
95
|
|
81
96
|
honeybee_model = Honeybee::Model.read_from_disk(model_json)
|
82
97
|
|
98
|
+
if schedule_csv_dir && !schedule_csv_dir.empty?
|
99
|
+
if !Dir.exist?(schedule_csv_dir)
|
100
|
+
runner.registerError("Directory for exported CSV Schedules does not exist '#{schedule_csv_dir}'")
|
101
|
+
return false
|
102
|
+
end
|
103
|
+
honeybee_model.set_schedule_csv_dir(schedule_csv_dir, include_datetimes)
|
104
|
+
end
|
105
|
+
|
83
106
|
STDOUT.flush
|
84
107
|
honeybee_model.to_openstudio_model(model)
|
85
108
|
STDOUT.flush
|
@@ -53,103 +53,103 @@ class OpenStudio::Model::Model
|
|
53
53
|
|
54
54
|
case system_type
|
55
55
|
|
56
|
-
when '
|
56
|
+
when 'ElectricBaseboard'
|
57
57
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_zones)
|
58
58
|
|
59
|
-
when '
|
59
|
+
when 'BoilerBaseboard'
|
60
60
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones)
|
61
61
|
|
62
|
-
when '
|
62
|
+
when 'ASHPBaseboard'
|
63
63
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'AirSourceHeatPump', znht = nil, cl = nil, heated_zones)
|
64
64
|
|
65
|
-
when '
|
65
|
+
when 'DHWBaseboard'
|
66
66
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'DistrictHeating', znht = nil, cl = nil, heated_zones)
|
67
67
|
|
68
|
-
when '
|
68
|
+
when 'EvapCoolers_ElectricBaseboard'
|
69
69
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_zones)
|
70
70
|
standard.model_add_hvac_system(self, 'Evaporative Cooler', ht = nil, znht = nil, cl = 'Electricity', cooled_zones)
|
71
71
|
|
72
|
-
when '
|
72
|
+
when 'EvapCoolers_BoilerBaseboard'
|
73
73
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones)
|
74
74
|
standard.model_add_hvac_system(self, 'Evaporative Cooler', ht = nil, znht = nil, cl = 'Electricity', cooled_zones)
|
75
75
|
|
76
|
-
when '
|
76
|
+
when 'EvapCoolers_ASHPBaseboard'
|
77
77
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'AirSourceHeatPump', znht = nil, cl = nil, heated_zones)
|
78
78
|
standard.model_add_hvac_system(self, 'Evaporative Cooler', ht = nil, znht = nil, cl = 'Electricity', cooled_zones)
|
79
79
|
|
80
|
-
when '
|
80
|
+
when 'EvapCoolers_DHWBaseboard'
|
81
81
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'DistrictHeating', znht = nil, cl = nil, heated_zones)
|
82
82
|
standard.model_add_hvac_system(self, 'Evaporative Cooler', ht = nil, znht = nil, cl = 'Electricity', cooled_zones)
|
83
83
|
|
84
|
-
when '
|
84
|
+
when 'EvapCoolers_Furnace'
|
85
85
|
# Using unit heater to represent forced air furnace to limit to one airloop per thermal zone.
|
86
86
|
standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones)
|
87
87
|
standard.model_add_hvac_system(self, 'Evaporative Cooler', ht = nil, znht = nil, cl = 'Electricity', cooled_zones)
|
88
88
|
|
89
|
-
when '
|
89
|
+
when 'EvapCoolers_UnitHeaters'
|
90
90
|
standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones)
|
91
91
|
standard.model_add_hvac_system(self, 'Evaporative Cooler', ht = nil, znht = nil, cl = 'Electricity', cooled_zones)
|
92
92
|
|
93
|
-
when '
|
93
|
+
when 'EvapCoolers'
|
94
94
|
standard.model_add_hvac_system(self, 'Evaporative Cooler', ht = nil, znht = nil, cl = 'Electricity', cooled_zones)
|
95
95
|
|
96
|
-
when '
|
96
|
+
when 'DOAS_FCU_Chiller_Boiler'
|
97
97
|
standard.model_add_hvac_system(self, 'DOAS', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones)
|
98
98
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones,
|
99
99
|
zone_equipment_ventilation: false)
|
100
100
|
|
101
|
-
when '
|
101
|
+
when 'DOAS_FCU_Chiller_ASHP'
|
102
102
|
standard.model_add_hvac_system(self, 'DOAS', ht = 'AirSourceHeatPump', znht = nil, cl = 'Electricity', zones)
|
103
103
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = 'AirSourceHeatPump', znht = nil, cl = 'Electricity', zones,
|
104
104
|
zone_equipment_ventilation: false)
|
105
105
|
|
106
|
-
when '
|
106
|
+
when 'DOAS_FCU_Chiller_DHW'
|
107
107
|
standard.model_add_hvac_system(self, 'DOAS', ht = 'DistrictHeating', znht = nil, cl = 'Electricity', zones)
|
108
108
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = 'DistrictHeating', znht = nil, cl = 'Electricity', zones,
|
109
109
|
zone_equipment_ventilation: false)
|
110
110
|
|
111
|
-
when '
|
111
|
+
when 'DOAS_FCU_Chiller_ElectricBaseboard'
|
112
112
|
standard.model_add_hvac_system(self, 'DOAS', ht = nil, znht = nil, cl = 'Electricity', zones,
|
113
113
|
air_loop_heating_type: nil)
|
114
114
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'Electricity', zones,
|
115
115
|
zone_equipment_ventilation: false)
|
116
116
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_zones)
|
117
117
|
|
118
|
-
when '
|
118
|
+
when 'DOAS_FCU_Chiller_GasHeaters'
|
119
119
|
standard.model_add_hvac_system(self, 'DOAS', ht = nil, znht = nil, cl = 'Electricity', zones,
|
120
120
|
air_loop_heating_type: nil)
|
121
121
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'Electricity', zones,
|
122
122
|
zone_equipment_ventilation: false)
|
123
123
|
standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones)
|
124
124
|
|
125
|
-
when '
|
125
|
+
when 'DOAS_FCU_Chiller'
|
126
126
|
standard.model_add_hvac_system(self, 'DOAS', ht = nil, znht = nil, cl = 'Electricity', zones,
|
127
127
|
air_loop_heating_type: nil)
|
128
128
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'Electricity', zones,
|
129
129
|
zone_equipment_ventilation: false)
|
130
130
|
|
131
|
-
when '
|
131
|
+
when 'DOAS_FCU_ACChiller_Boiler'
|
132
132
|
standard.model_add_hvac_system(self, 'DOAS', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones,
|
133
133
|
chilled_water_loop_cooling_type: 'AirCooled')
|
134
134
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones,
|
135
135
|
chilled_water_loop_cooling_type: 'AirCooled',
|
136
136
|
zone_equipment_ventilation: false)
|
137
137
|
|
138
|
-
when '
|
138
|
+
when 'DOAS_FCU_ACChiller_ASHP'
|
139
139
|
standard.model_add_hvac_system(self, 'DOAS', ht = 'AirSourceHeatPump', znht = nil, cl = 'Electricity', zones,
|
140
140
|
chilled_water_loop_cooling_type: 'AirCooled')
|
141
141
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = 'AirSourceHeatPump', znht = nil, cl = 'Electricity', zones,
|
142
142
|
chilled_water_loop_cooling_type: 'AirCooled',
|
143
143
|
zone_equipment_ventilation: false)
|
144
144
|
|
145
|
-
when '
|
145
|
+
when 'DOAS_FCU_ACChiller_DHW'
|
146
146
|
standard.model_add_hvac_system(self, 'DOAS', ht = 'DistrictHeating', znht = nil, cl = 'Electricity', zones,
|
147
147
|
chilled_water_loop_cooling_type: 'AirCooled')
|
148
148
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = 'DistrictHeating', znht = nil, cl = 'Electricity', zones,
|
149
149
|
chilled_water_loop_cooling_type: 'AirCooled',
|
150
150
|
zone_equipment_ventilation: false)
|
151
151
|
|
152
|
-
when '
|
152
|
+
when 'DOAS_FCU_ACChiller_ElectricBaseboard'
|
153
153
|
standard.model_add_hvac_system(self, 'DOAS', ht = nil, znht = nil, cl = 'Electricity', zones,
|
154
154
|
chilled_water_loop_cooling_type: 'AirCooled', air_loop_heating_type: nil)
|
155
155
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'Electricity', zones,
|
@@ -157,7 +157,7 @@ class OpenStudio::Model::Model
|
|
157
157
|
zone_equipment_ventilation: false)
|
158
158
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_zones)
|
159
159
|
|
160
|
-
when '
|
160
|
+
when 'DOAS_FCU_ACChiller_GasHeaters'
|
161
161
|
standard.model_add_hvac_system(self, 'DOAS', ht = nil, znht = nil, cl = 'Electricity', zones,
|
162
162
|
chilled_water_loop_cooling_type: 'AirCooled', air_loop_heating_type: nil)
|
163
163
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'Electricity', zones,
|
@@ -165,194 +165,194 @@ class OpenStudio::Model::Model
|
|
165
165
|
zone_equipment_ventilation: false)
|
166
166
|
standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones)
|
167
167
|
|
168
|
-
when '
|
168
|
+
when 'DOAS_FCU_ACChiller'
|
169
169
|
standard.model_add_hvac_system(self, 'DOAS', ht = nil, znht = nil, cl = 'Electricity', zones,
|
170
170
|
chilled_water_loop_cooling_type: 'AirCooled', air_loop_heating_type: nil)
|
171
171
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'Electricity', zones,
|
172
172
|
chilled_water_loop_cooling_type: 'AirCooled',
|
173
173
|
zone_equipment_ventilation: false)
|
174
174
|
|
175
|
-
when '
|
175
|
+
when 'DOAS_FCU_DCW_Boiler'
|
176
176
|
standard.model_add_hvac_system(self, 'DOAS', ht = 'NaturalGas', znht = nil, cl = 'DistrictCooling', zones)
|
177
177
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = 'NaturalGas', znht = nil, cl = 'DistrictCooling', zones,
|
178
178
|
zone_equipment_ventilation: false)
|
179
179
|
|
180
|
-
when '
|
180
|
+
when 'DOAS_FCU_DCW_ASHP'
|
181
181
|
standard.model_add_hvac_system(self, 'DOAS', ht = 'AirSourceHeatPump', znht = nil, cl = 'DistrictCooling', zones)
|
182
182
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = 'AirSourceHeatPump', znht = nil, cl = 'DistrictCooling', zones,
|
183
183
|
zone_equipment_ventilation: false)
|
184
184
|
|
185
|
-
when '
|
185
|
+
when 'DOAS_FCU_DCW_DHW'
|
186
186
|
standard.model_add_hvac_system(self, 'DOAS', ht = 'DistrictHeating', znht = nil, cl = 'DistrictCooling', zones)
|
187
187
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = 'DistrictHeating', znht = nil, cl = 'DistrictCooling', zones,
|
188
188
|
zone_equipment_ventilation: false)
|
189
189
|
|
190
|
-
when '
|
190
|
+
when 'DOAS_FCU_DCW_ElectricBaseboard'
|
191
191
|
standard.model_add_hvac_system(self, 'DOAS', ht = nil, znht = nil, cl = 'DistrictCooling', zones,
|
192
192
|
air_loop_heating_type: nil)
|
193
193
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'DistrictCooling', zones,
|
194
194
|
zone_equipment_ventilation: false)
|
195
195
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_zones)
|
196
196
|
|
197
|
-
when '
|
197
|
+
when 'DOAS_FCU_DCW_GasHeaters'
|
198
198
|
standard.model_add_hvac_system(self, 'DOAS', ht = nil, znht = nil, cl = 'DistrictCooling', zones,
|
199
199
|
air_loop_heating_type: nil)
|
200
200
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'DistrictCooling', zones,
|
201
201
|
zone_equipment_ventilation: false)
|
202
202
|
standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones)
|
203
203
|
|
204
|
-
when '
|
204
|
+
when 'DOAS_FCU_DCW'
|
205
205
|
standard.model_add_hvac_system(self, 'DOAS', ht = nil, znht = nil, cl = 'DistrictCooling', zones,
|
206
206
|
air_loop_heating_type: nil)
|
207
207
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'DistrictCooling', zones,
|
208
208
|
zone_equipment_ventilation: false)
|
209
209
|
|
210
|
-
when '
|
210
|
+
when 'DOAS_VRF'
|
211
211
|
standard.model_add_hvac_system(self, 'DOAS', ht = 'Electricity', znht = nil, cl = 'Electricity', zones,
|
212
212
|
air_loop_heating_type: 'DX',
|
213
213
|
air_loop_cooling_type: 'DX')
|
214
214
|
standard.model_add_hvac_system(self, 'VRF', ht = 'Electricity', znht = nil, cl = 'Electricity', zones)
|
215
215
|
|
216
|
-
when '
|
216
|
+
when 'DOAS_WSHP_FluidCooler_Boiler'
|
217
217
|
standard.model_add_hvac_system(self, 'DOAS', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones)
|
218
218
|
standard.model_add_hvac_system(self, 'Water Source Heat Pumps', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones,
|
219
219
|
heat_pump_loop_cooling_type: 'FluidCooler',
|
220
220
|
zone_equipment_ventilation: false)
|
221
221
|
|
222
|
-
when '
|
222
|
+
when 'DOAS_WSHP_CoolingTower_Boiler'
|
223
223
|
standard.model_add_hvac_system(self, 'DOAS', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones)
|
224
224
|
standard.model_add_hvac_system(self, 'Water Source Heat Pumps', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones,
|
225
225
|
heat_pump_loop_cooling_type: 'CoolingTower',
|
226
226
|
zone_equipment_ventilation: false)
|
227
227
|
|
228
|
-
when '
|
228
|
+
when 'DOAS_WSHP_GSHP'
|
229
229
|
standard.model_add_hvac_system(self, 'DOAS', ht = 'Electricity', znht = nil, cl = 'Electricity', zones,
|
230
230
|
air_loop_heating_type: 'DX',
|
231
231
|
air_loop_cooling_type: 'DX')
|
232
232
|
standard.model_add_hvac_system(self, 'Ground Source Heat Pumps', ht = 'Electricity', znht = nil, cl = 'Electricity', zones,
|
233
233
|
zone_equipment_ventilation: false)
|
234
234
|
|
235
|
-
when '
|
235
|
+
when 'DOAS_WSHP_DCW_DHW'
|
236
236
|
standard.model_add_hvac_system(self, 'DOAS', ht = 'DistrictHeating', znht = nil, cl = 'DistrictCooling', zones)
|
237
237
|
standard.model_add_hvac_system(self, 'Water Source Heat Pumps', ht = 'DistrictHeating', znht = nil, cl = 'DistrictCooling', zones,
|
238
238
|
zone_equipment_ventilation: false)
|
239
239
|
|
240
240
|
# ventilation provided by zone fan coil unit in fan coil systems
|
241
|
-
when '
|
241
|
+
when 'FCU_Chiller_Boiler'
|
242
242
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones)
|
243
243
|
|
244
|
-
when '
|
244
|
+
when 'FCU_Chiller_ASHP'
|
245
245
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = 'AirSourceHeatPump', znht = nil, cl = 'Electricity', zones)
|
246
246
|
|
247
|
-
when '
|
247
|
+
when 'FCU_Chiller_DHW'
|
248
248
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = 'DistrictHeating', znht = nil, cl = 'Electricity', zones)
|
249
249
|
|
250
|
-
when '
|
250
|
+
when 'FCU_Chiller_ElectricBaseboard'
|
251
251
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'Electricity', zones)
|
252
252
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_zones)
|
253
253
|
|
254
|
-
when '
|
254
|
+
when 'FCU_Chiller_GasHeaters'
|
255
255
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'Electricity', zones)
|
256
256
|
standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones)
|
257
257
|
|
258
|
-
when '
|
258
|
+
when 'FCU_Chiller'
|
259
259
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'Electricity', zones)
|
260
260
|
|
261
|
-
when '
|
261
|
+
when 'FCU_ACChiller_Boiler'
|
262
262
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones,
|
263
263
|
chilled_water_loop_cooling_type: 'AirCooled')
|
264
264
|
|
265
|
-
when '
|
265
|
+
when 'FCU_ACChiller_ASHP'
|
266
266
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = 'AirSourceHeatPump', znht = nil, cl = 'Electricity', zones,
|
267
267
|
chilled_water_loop_cooling_type: 'AirCooled')
|
268
268
|
|
269
|
-
when '
|
269
|
+
when 'FCU_ACChiller_DHW'
|
270
270
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = 'DistrictHeating', znht = nil, cl = 'Electricity', zones,
|
271
271
|
chilled_water_loop_cooling_type: 'AirCooled')
|
272
272
|
|
273
|
-
when '
|
273
|
+
when 'FCU_ACChiller_ElectricBaseboard'
|
274
274
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'Electricity', zones,
|
275
275
|
chilled_water_loop_cooling_type: 'AirCooled')
|
276
276
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_zones)
|
277
277
|
|
278
|
-
when '
|
278
|
+
when 'FCU_ACChiller_GasHeaters'
|
279
279
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'Electricity', zones,
|
280
280
|
chilled_water_loop_cooling_type: 'AirCooled')
|
281
281
|
standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones)
|
282
282
|
|
283
|
-
when '
|
283
|
+
when 'FCU_ACChiller'
|
284
284
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'Electricity', zones,
|
285
285
|
chilled_water_loop_cooling_type: 'AirCooled')
|
286
286
|
|
287
|
-
when '
|
287
|
+
when 'FCU_DCW_Boiler'
|
288
288
|
standard.model_add_hvac_system(self, 'Fan Coil ', ht = 'NaturalGas', znht = nil, cl = 'DistrictCooling', zones)
|
289
289
|
|
290
|
-
when '
|
290
|
+
when 'FCU_DCW_ASHP'
|
291
291
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = 'AirSourceHeatPump', znht = nil, cl = 'DistrictCooling', zones)
|
292
292
|
|
293
|
-
when '
|
293
|
+
when 'FCU_DCW_DHW'
|
294
294
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = 'DistrictHeating', znht = nil, cl = 'DistrictCooling', zones)
|
295
295
|
|
296
|
-
when '
|
296
|
+
when 'FCU_DCW_ElectricBaseboard'
|
297
297
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'DistrictCooling', zones)
|
298
298
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_zones)
|
299
299
|
|
300
|
-
when '
|
300
|
+
when 'FCU_DCW_GasHeaters'
|
301
301
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'DistrictCooling', zones)
|
302
302
|
standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones)
|
303
303
|
|
304
|
-
when '
|
304
|
+
when 'FCU_DCW'
|
305
305
|
standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'DistrictCooling', zones)
|
306
306
|
|
307
|
-
when '
|
307
|
+
when 'Furnace'
|
308
308
|
# includes ventilation, whereas residential forced air furnace does not.
|
309
309
|
standard.model_add_hvac_system(self, 'Forced Air Furnace', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones)
|
310
310
|
|
311
|
-
when '
|
311
|
+
when 'GasHeaters'
|
312
312
|
standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones)
|
313
313
|
|
314
|
-
when '
|
314
|
+
when 'PTAC_ElectricBaseboard'
|
315
315
|
standard.model_add_hvac_system(self, 'PTAC', ht = nil, znht = nil, cl = 'Electricity', system_zones)
|
316
316
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_zones)
|
317
317
|
|
318
|
-
when '
|
318
|
+
when 'PTAC_BoilerBaseboard'
|
319
319
|
standard.model_add_hvac_system(self, 'PTAC', ht = nil, znht = nil, cl = 'Electricity', system_zones)
|
320
320
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones)
|
321
321
|
|
322
|
-
when '
|
322
|
+
when 'PTAC_DHWBaseboard'
|
323
323
|
standard.model_add_hvac_system(self, 'PTAC', ht = nil, znht = nil, cl = 'Electricity', system_zones)
|
324
324
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'DistrictHeating', znht = nil, cl = nil, heated_zones)
|
325
325
|
|
326
|
-
when '
|
326
|
+
when 'PTAC_GasHeaters'
|
327
327
|
standard.model_add_hvac_system(self, 'PTAC', ht = nil, znht = nil, cl = 'Electricity', system_zones)
|
328
328
|
standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones)
|
329
329
|
|
330
|
-
when '
|
330
|
+
when 'PTAC_ElectricCoil'
|
331
331
|
standard.model_add_hvac_system(self, 'PTAC', ht = nil, znht = 'Electricity', cl = 'Electricity', system_zones)
|
332
332
|
# use 'Baseboard electric' for heated only zones
|
333
333
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_only_zones)
|
334
334
|
|
335
|
-
when '
|
335
|
+
when 'PTAC_GasCoil'
|
336
336
|
standard.model_add_hvac_system(self, 'PTAC', ht = nil, znht = 'NaturalGas', cl = 'Electricity', system_zones)
|
337
337
|
# use 'Baseboard electric' for heated only zones
|
338
338
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_only_zones)
|
339
339
|
|
340
|
-
when '
|
340
|
+
when 'PTAC_Boiler'
|
341
341
|
standard.model_add_hvac_system(self, 'PTAC', ht = 'NaturalGas', znht = nil, cl = 'Electricity', system_zones)
|
342
342
|
# use 'Baseboard gas boiler' for heated only zones
|
343
343
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'NaturalGas', znht = nil, cl = nil, heated_only_zones)
|
344
344
|
|
345
|
-
when '
|
345
|
+
when 'PTAC_ASHP'
|
346
346
|
standard.model_add_hvac_system(self, 'PTAC', ht = 'AirSourceHeatPump', znht = nil, cl = 'Electricity', system_zones)
|
347
347
|
# use 'Baseboard central air source heat pump' for heated only zones
|
348
348
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'AirSourceHeatPump', znht = nil, cl = nil, heated_only_zones)
|
349
349
|
|
350
|
-
when '
|
350
|
+
when 'PTAC_DHW'
|
351
351
|
standard.model_add_hvac_system(self, 'PTAC', ht = 'DistrictHeating', znht = nil, cl = 'Electricity', system_zones)
|
352
352
|
# use 'Baseboard district hot water heat' for heated only zones
|
353
353
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'DistrictHeating', znht = nil, cl = nil, heated_only_zones)
|
354
354
|
|
355
|
-
when 'PTAC
|
355
|
+
when 'PTAC'
|
356
356
|
standard.model_add_hvac_system(self, 'PTAC', ht = nil, znht = nil, cl = 'Electricity', system_zones)
|
357
357
|
|
358
358
|
when 'PTHP'
|
@@ -360,277 +360,235 @@ class OpenStudio::Model::Model
|
|
360
360
|
# use 'Baseboard electric' for heated only zones
|
361
361
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_only_zones)
|
362
362
|
|
363
|
-
when '
|
363
|
+
when 'PSZAC_ElectricBaseboard'
|
364
364
|
standard.model_add_hvac_system(self, 'PSZ-AC', ht = nil, znht = nil, cl = 'Electricity', system_zones)
|
365
365
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_zones)
|
366
366
|
|
367
|
-
when '
|
367
|
+
when 'PSZAC_BoilerBaseboard'
|
368
368
|
standard.model_add_hvac_system(self, 'PSZ-AC', ht = nil, znht = nil, cl = 'Electricity', system_zones)
|
369
369
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones)
|
370
370
|
|
371
|
-
when '
|
371
|
+
when 'PSZAC_DHWBaseboard'
|
372
372
|
standard.model_add_hvac_system(self, 'PSZ-AC', ht = nil, znht = nil, cl = 'Electricity', system_zones)
|
373
373
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'DistrictHeating', znht = nil, cl = nil, heated_zones)
|
374
374
|
|
375
|
-
when '
|
375
|
+
when 'PSZAC_GasHeaters'
|
376
376
|
standard.model_add_hvac_system(self, 'PSZ-AC', ht = nil, znht = nil, cl = 'Electricity', system_zones)
|
377
377
|
standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones)
|
378
378
|
|
379
|
-
when '
|
379
|
+
when 'PSZAC_ElectricCoil'
|
380
380
|
standard.model_add_hvac_system(self, 'PSZ-AC', ht = nil, znht = 'Electricity', cl = 'Electricity', system_zones)
|
381
381
|
# use 'Baseboard electric' for heated only zones
|
382
382
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_only_zones)
|
383
383
|
|
384
|
-
when '
|
384
|
+
when 'PSZAC_GasCoil'
|
385
385
|
standard.model_add_hvac_system(self, 'PSZ-AC', ht = nil, znht = 'NaturalGas', cl = 'Electricity', system_zones)
|
386
386
|
# use 'Baseboard electric' for heated only zones
|
387
387
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_only_zones)
|
388
388
|
|
389
|
-
when '
|
389
|
+
when 'PSZAC_Boiler'
|
390
390
|
standard.model_add_hvac_system(self, 'PSZ-AC', ht = 'NaturalGas', znht = nil, cl = 'Electricity', system_zones)
|
391
391
|
# use 'Baseboard gas boiler' for heated only zones
|
392
392
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'NaturalGas', znht = nil, cl = nil, heated_only_zones)
|
393
393
|
|
394
|
-
when '
|
394
|
+
when 'PSZAC_ASHP'
|
395
395
|
standard.model_add_hvac_system(self, 'PSZ-AC', ht = 'AirSourceHeatPump', znht = nil, cl = 'Electricity', system_zones)
|
396
396
|
# use 'Baseboard central air source heat pump' for heated only zones
|
397
397
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'AirSourceHeatPump', znht = nil, cl = nil, heated_only_zones)
|
398
398
|
|
399
|
-
when '
|
399
|
+
when 'PSZAC_DHW'
|
400
400
|
standard.model_add_hvac_system(self, 'PSZ-AC', ht = 'DistrictHeating', znht = nil, cl = 'Electricity', system_zones)
|
401
401
|
# use 'Baseboard district hot water' for heated only zones
|
402
402
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'DistrictHeating', znht = nil, cl = nil, heated_only_zones)
|
403
403
|
|
404
|
-
when '
|
404
|
+
when 'PSZAC'
|
405
405
|
standard.model_add_hvac_system(self, 'PSZ-AC', ht = nil, znht = nil, cl = 'Electricity', cooled_zones)
|
406
406
|
|
407
|
-
when '
|
407
|
+
when 'PSZAC_DCW_ElectricBaseboard'
|
408
408
|
standard.model_add_hvac_system(self, 'PSZ-AC', ht = nil, znht = nil, cl = 'DistrictCooling', system_zones)
|
409
409
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_zones)
|
410
410
|
|
411
|
-
when '
|
411
|
+
when 'PSZAC_DCW_BoilerBaseboard'
|
412
412
|
standard.model_add_hvac_system(self, 'PSZ-AC', ht = nil, znht = nil, cl = 'DistrictCooling', system_zones)
|
413
413
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones)
|
414
414
|
|
415
|
-
when '
|
415
|
+
when 'PSZAC_DCW_GasHeaters'
|
416
416
|
standard.model_add_hvac_system(self, 'PSZ-AC', ht = nil, znht = nil, cl = 'DistrictCooling', system_zones)
|
417
417
|
standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones)
|
418
418
|
|
419
|
-
when '
|
419
|
+
when 'PSZAC_DCW_ElectricCoil'
|
420
420
|
standard.model_add_hvac_system(self, 'PSZ-AC', ht = nil, znht = 'Electricity', cl = 'DistrictCooling', system_zones)
|
421
421
|
# use 'Baseboard electric' for heated only zones
|
422
422
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_only_zones)
|
423
423
|
|
424
|
-
when '
|
424
|
+
when 'PSZAC_DCW_GasCoil'
|
425
425
|
standard.model_add_hvac_system(self, 'PSZ-AC', ht = nil, znht = 'NaturalGas', cl = 'DistrictCooling', system_zones)
|
426
426
|
# use 'Baseboard electric' for heated only zones
|
427
427
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_only_zones)
|
428
428
|
|
429
|
-
when '
|
429
|
+
when 'PSZAC_DCW_Boiler'
|
430
430
|
standard.model_add_hvac_system(self, 'PSZ-AC', ht = 'NaturalGas', znht = nil, cl = 'DistrictCooling', system_zones)
|
431
431
|
# use 'Baseboard gas boiler' for heated only zones
|
432
432
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'NaturalGas', znht = nil, cl = nil, heated_only_zones)
|
433
433
|
|
434
|
-
when '
|
434
|
+
when 'PSZAC_DCW_ASHP'
|
435
435
|
standard.model_add_hvac_system(self, 'PSZ-AC', ht = 'AirSourceHeatPump', znht = nil, cl = 'DistrictCooling', system_zones)
|
436
436
|
# use 'Baseboard central air source heat pump' for heated only zones
|
437
437
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'AirSourceHeatPump', znht = nil, cl = nil, heated_only_zones)
|
438
438
|
|
439
|
-
when '
|
439
|
+
when 'PSZAC_DCW_DHW'
|
440
440
|
standard.model_add_hvac_system(self, 'PSZ-AC', ht = 'DistrictHeating', znht = nil, cl = 'DistrictCooling', system_zones)
|
441
441
|
# use 'Baseboard district hot water' for heated only zones
|
442
442
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'DistrictHeating', znht = nil, cl = nil, heated_only_zones)
|
443
443
|
|
444
|
-
when '
|
444
|
+
when 'PSZAC_DCW'
|
445
445
|
standard.model_add_hvac_system(self, 'PSZ-AC', ht = nil, znht = nil, cl = 'DistrictCooling', cooled_zones)
|
446
446
|
|
447
|
-
when '
|
447
|
+
when 'PSZHP'
|
448
448
|
standard.model_add_hvac_system(self, 'PSZ-HP', ht = 'Electricity', znht = nil, cl = 'Electricity', system_zones)
|
449
449
|
# use 'Baseboard electric' for heated only zones
|
450
450
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_only_zones)
|
451
451
|
|
452
452
|
# PVAV systems by default use a DX coil for cooling
|
453
|
-
when '
|
453
|
+
when 'PVAV_Boiler'
|
454
454
|
standard.model_add_hvac_system(self, 'PVAV Reheat', ht = 'NaturalGas', znht = 'NaturalGas', cl = 'Electricity', zones)
|
455
455
|
|
456
|
-
when '
|
456
|
+
when 'PVAV_ASHP'
|
457
457
|
standard.model_add_hvac_system(self, 'PVAV Reheat', ht = 'AirSourceHeatPump', znht = 'AirSourceHeatPump', cl = 'Electricity', zones)
|
458
458
|
|
459
|
-
when '
|
459
|
+
when 'PVAV_DHW'
|
460
460
|
standard.model_add_hvac_system(self, 'PVAV Reheat', ht = 'DistrictHeating', znht = 'DistrictHeating', cl = 'Electricity', zones)
|
461
461
|
|
462
|
-
when '
|
462
|
+
when 'PVAV_PFP'
|
463
463
|
standard.model_add_hvac_system(self, 'PVAV PFP Boxes', ht = 'Electricity', znht = 'Electricity', cl = 'Electricity', zones)
|
464
464
|
|
465
|
-
when '
|
465
|
+
when 'PVAV_BoilerElectricReheat'
|
466
466
|
standard.model_add_hvac_system(self, 'PVAV Reheat', ht = 'Gas', znht = 'Electricity', cl = 'Electricity', zones)
|
467
467
|
|
468
468
|
# all residential systems do not have ventilation
|
469
|
-
when '
|
469
|
+
when 'ResidentialAC_ElectricBaseboard'
|
470
470
|
standard.model_add_hvac_system(self, 'Residential AC', ht = nil, znht = nil, cl = nil, cooled_zones)
|
471
471
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_zones)
|
472
472
|
|
473
|
-
when '
|
473
|
+
when 'ResidentialAC_BoilerBaseboard'
|
474
474
|
standard.model_add_hvac_system(self, 'Residential AC', ht = nil, znht = nil, cl = nil, cooled_zones)
|
475
475
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones)
|
476
476
|
|
477
|
-
when '
|
477
|
+
when 'ResidentialAC_ASHPBaseboard'
|
478
478
|
standard.model_add_hvac_system(self, 'Residential AC', ht = nil, znht = nil, cl = nil, cooled_zones)
|
479
479
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'AirSourceHeatPump', znht = nil, cl = nil, heated_zones)
|
480
480
|
|
481
|
-
when '
|
481
|
+
when 'ResidentialAC_DHWBaseboard'
|
482
482
|
standard.model_add_hvac_system(self, 'Residential AC', ht = nil, znht = nil, cl = nil, cooled_zones)
|
483
483
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'DistrictHeating', znht = nil, cl = nil, heated_zones)
|
484
484
|
|
485
|
-
when '
|
485
|
+
when 'ResidentialAC_ResidentialFurnace'
|
486
486
|
standard.model_add_hvac_system(self, 'Residential Forced Air Furnace with AC', ht = nil, znht = nil, cl = nil, zones)
|
487
487
|
|
488
|
-
when '
|
488
|
+
when 'ResidentialAC'
|
489
489
|
standard.model_add_hvac_system(self, 'Residential AC', ht = nil, znht = nil, cl = nil, cooled_zones)
|
490
490
|
|
491
|
-
when '
|
491
|
+
when 'ResidentialHP'
|
492
492
|
standard.model_add_hvac_system(self, 'Residential Air Source Heat Pump', ht = 'Electricity', znht = nil, cl = 'Electricity', zones)
|
493
493
|
|
494
|
-
when '
|
494
|
+
when 'ResidentialHPNoCool'
|
495
495
|
standard.model_add_hvac_system(self, 'Residential Air Source Heat Pump', ht = 'Electricity', znht = nil, cl = nil, heated_zones)
|
496
496
|
|
497
|
-
when '
|
497
|
+
when 'ResidentialFurnace'
|
498
498
|
standard.model_add_hvac_system(self, 'Residential Forced Air Furnace', ht = 'NaturalGas', znht = nil, cl = nil, zones)
|
499
499
|
|
500
|
-
when '
|
500
|
+
when 'VAV_Chiller_Boiler'
|
501
501
|
standard.model_add_hvac_system(self, 'VAV Reheat', ht = 'NaturalGas', znht = 'NaturalGas', cl = 'Electricity', zones)
|
502
502
|
|
503
|
-
when '
|
503
|
+
when 'VAV_Chiller_ASHP'
|
504
504
|
standard.model_add_hvac_system(self, 'VAV Reheat', ht = 'AirSourceHeatPump', znht = 'AirSourceHeatPump', cl = 'Electricity', zones)
|
505
505
|
|
506
|
-
when '
|
506
|
+
when 'VAV_Chiller_DHW'
|
507
507
|
standard.model_add_hvac_system(self, 'VAV Reheat', ht = 'DistrictHeating', znht = 'DistrictHeating', cl = 'Electricity', zones)
|
508
508
|
|
509
|
-
when '
|
509
|
+
when 'VAV_Chiller_PFP'
|
510
510
|
standard.model_add_hvac_system(self, 'VAV PFP Boxes', ht = 'NaturalGas', znht = 'NaturalGas', cl = 'Electricity', zones)
|
511
511
|
|
512
|
-
when '
|
512
|
+
when 'VAV_Chiller_GasCoil'
|
513
513
|
standard.model_add_hvac_system(self, 'VAV Gas Reheat', ht = 'NaturalGas', ht = 'NaturalGas', cl = 'Electricity', zones)
|
514
514
|
|
515
|
-
when '
|
516
|
-
standard.model_add_hvac_system(self, 'VAV No Reheat', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones)
|
517
|
-
standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_zones)
|
518
|
-
|
519
|
-
when 'VAV chiller with no reheat with gas unit heaters'
|
520
|
-
standard.model_add_hvac_system(self, 'VAV No Reheat', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones)
|
521
|
-
standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones)
|
522
|
-
|
523
|
-
when 'VAV chiller with no reheat with zone heat pump'
|
524
|
-
standard.model_add_hvac_system(self, 'VAV No Reheat', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones)
|
525
|
-
# Using PTHP to represent zone heat pump to limit to one airloop per thermal zone.
|
526
|
-
standard.model_add_hvac_system(self, 'PTHP', ht = 'Electricity', znht = nil, cl = 'Electricity', zones)
|
527
|
-
|
528
|
-
when 'VAV air-cooled chiller with gas boiler reheat'
|
515
|
+
when 'VAV_ACChiller_Boiler'
|
529
516
|
standard.model_add_hvac_system(self, 'VAV Reheat', ht = 'NaturalGas', znht = 'NaturalGas', cl = 'Electricity', zones,
|
530
517
|
chilled_water_loop_cooling_type: 'AirCooled')
|
531
518
|
|
532
|
-
when '
|
519
|
+
when 'VAV_ACChiller_ASHP'
|
533
520
|
standard.model_add_hvac_system(self, 'VAV Reheat', ht = 'AirSourceHeatPump', znht = 'AirSourceHeatPump', cl = 'Electricity', zones,
|
534
521
|
chilled_water_loop_cooling_type: 'AirCooled')
|
535
522
|
|
536
|
-
when '
|
523
|
+
when 'VAV_ACChiller_DHW'
|
537
524
|
standard.model_add_hvac_system(self, 'VAV Reheat', ht = 'DistrictHeating', znht = 'DistrictHeating', cl = 'Electricity', zones,
|
538
525
|
chilled_water_loop_cooling_type: 'AirCooled')
|
539
526
|
|
540
|
-
when '
|
527
|
+
when 'VAV_ACChiller_PFP'
|
541
528
|
standard.model_add_hvac_system(self, 'VAV PFP Boxes', ht = 'NaturalGas', znht = 'NaturalGas', cl = 'Electricity', zones,
|
542
529
|
chilled_water_loop_cooling_type: 'AirCooled')
|
543
530
|
|
544
|
-
when '
|
531
|
+
when 'VAV_ACChiller_GasCoil'
|
545
532
|
standard.model_add_hvac_system(self, 'VAV Gas Reheat', ht = 'NaturalGas', ht = 'NaturalGas', cl = 'Electricity', zones,
|
546
533
|
chilled_water_loop_cooling_type: 'AirCooled')
|
547
534
|
|
548
|
-
when '
|
549
|
-
standard.model_add_hvac_system(self, 'VAV No Reheat', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones,
|
550
|
-
chilled_water_loop_cooling_type: 'AirCooled')
|
551
|
-
standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_zones)
|
552
|
-
|
553
|
-
when 'VAV air-cooled chiller with no reheat with gas unit heaters'
|
554
|
-
standard.model_add_hvac_system(self, 'VAV No Reheat', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones,
|
555
|
-
chilled_water_loop_cooling_type: 'AirCooled')
|
556
|
-
standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones)
|
557
|
-
|
558
|
-
when 'VAV air-cooled chiller with no reheat with zone heat pump'
|
559
|
-
standard.model_add_hvac_system(self, 'VAV No Reheat', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones,
|
560
|
-
chilled_water_loop_cooling_type: 'AirCooled')
|
561
|
-
# Using PTHP to represent zone heat pump to limit to one airloop per thermal zone.
|
562
|
-
standard.model_add_hvac_system(self, 'PTHP', ht = 'Electricity', znht = nil, cl = 'Electricity', zones)
|
563
|
-
|
564
|
-
when 'VAV district chilled water with gas boiler reheat'
|
535
|
+
when 'VAV_DCW_Boiler'
|
565
536
|
standard.model_add_hvac_system(self, 'VAV Reheat', ht = 'NaturalGas', znht = 'NaturalGas', cl = 'DistrictCooling', zones)
|
566
537
|
|
567
|
-
when '
|
538
|
+
when 'VAV_DCW_ASHP'
|
568
539
|
standard.model_add_hvac_system(self, 'VAV Reheat', ht = 'AirSourceHeatPump', znht = 'AirSourceHeatPump', cl = 'DistrictCooling', zones)
|
569
540
|
|
570
|
-
when '
|
541
|
+
when 'VAV_DCW_DHW'
|
571
542
|
standard.model_add_hvac_system(self, 'VAV Reheat', ht = 'DistrictHeating', znht = 'DistrictHeating', cl = 'DistrictCooling', zones)
|
572
543
|
|
573
|
-
when '
|
544
|
+
when 'VAV_DCW_PFP'
|
574
545
|
standard.model_add_hvac_system(self, 'VAV PFP Boxes', ht = 'NaturalGas', znht = 'NaturalGas', cl = 'DistrictCooling', zones)
|
575
546
|
|
576
|
-
when '
|
547
|
+
when 'VAV_DCW_GasCoil'
|
577
548
|
standard.model_add_hvac_system(self, 'VAV Gas Reheat', ht = 'NaturalGas', ht = 'NaturalGas', cl = 'DistrictCooling', zones)
|
578
549
|
|
579
|
-
when 'VAV district chilled water with no reheat with baseboard electric'
|
580
|
-
standard.model_add_hvac_system(self, 'VAV No Reheat', ht = 'NaturalGas', znht = nil, cl = 'DistrictCooling', zones)
|
581
|
-
standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_zones)
|
582
|
-
|
583
|
-
when 'VAV district chilled water with no reheat with gas unit heaters'
|
584
|
-
standard.model_add_hvac_system(self, 'VAV No Reheat', ht = 'NaturalGas', znht = nil, cl = 'DistrictCooling', zones)
|
585
|
-
standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones)
|
586
|
-
|
587
|
-
when 'VAV district chilled water with no reheat with zone heat pump'
|
588
|
-
standard.model_add_hvac_system(self, 'VAV No Reheat', ht = 'NaturalGas', znht = nil, cl = 'DistrictCooling', zones)
|
589
|
-
# Using PTHP to represent zone heat pump to limit to one airloop per thermal zone.
|
590
|
-
standard.model_add_hvac_system(self, 'PTHP', ht = 'Electricity', znht = nil, cl = 'Electricity', zones)
|
591
|
-
|
592
550
|
when 'VRF'
|
593
551
|
standard.model_add_hvac_system(self, 'VRF', ht = 'Electricity', znht = nil, cl = 'Electricity', zones)
|
594
552
|
|
595
|
-
when '
|
553
|
+
when 'WSHP_FluidCooler_Boiler'
|
596
554
|
standard.model_add_hvac_system(self, 'Water Source Heat Pumps', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones,
|
597
555
|
heat_pump_loop_cooling_type: 'FluidCooler')
|
598
556
|
|
599
|
-
when '
|
557
|
+
when 'WSHP_CoolingTower_Boiler'
|
600
558
|
standard.model_add_hvac_system(self, 'Water Source Heat Pumps', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones,
|
601
559
|
heat_pump_loop_cooling_type: 'CoolingTower')
|
602
560
|
|
603
|
-
when '
|
561
|
+
when 'WSHP_GSHP'
|
604
562
|
standard.model_add_hvac_system(self, 'Ground Source Heat Pumps', ht = 'Electricity', znht = nil, cl = 'Electricity', zones)
|
605
563
|
|
606
|
-
when '
|
564
|
+
when 'WSHP_DCW_DHW'
|
607
565
|
standard.model_add_hvac_system(self, 'Water Source Heat Pumps', ht = 'DistrictHeating', znht = nil, cl = 'DistrictCooling', zones)
|
608
566
|
|
609
|
-
when '
|
567
|
+
when 'WindowAC_ElectricBaseboard'
|
610
568
|
standard.model_add_hvac_system(self, 'Window AC', ht = nil, znht = nil, cl = 'Electricity', cooled_zones)
|
611
569
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_zones)
|
612
570
|
|
613
|
-
when '
|
571
|
+
when 'WindowAC_BoilerBaseboard'
|
614
572
|
standard.model_add_hvac_system(self, 'Window AC', ht = nil, znht = nil, cl = 'Electricity', cooled_zones)
|
615
573
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones)
|
616
574
|
|
617
|
-
when '
|
575
|
+
when 'WindowAC_ASHPBaseboard'
|
618
576
|
standard.model_add_hvac_system(self, 'Window AC', ht = nil, znht = nil, cl = 'Electricity', cooled_zones)
|
619
577
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'AirSourceHeatPump', znht = nil, cl = nil, heated_zones)
|
620
578
|
|
621
|
-
when '
|
579
|
+
when 'WindowAC_DHWBaseboard'
|
622
580
|
standard.model_add_hvac_system(self, 'Window AC', ht = nil, znht = nil, cl = 'Electricity', cooled_zones)
|
623
581
|
standard.model_add_hvac_system(self, 'Baseboards', ht = 'DistrictHeating', znht = nil, cl = nil, heated_zones)
|
624
582
|
|
625
|
-
when '
|
583
|
+
when 'WindowAC_Furnace'
|
626
584
|
standard.model_add_hvac_system(self, 'Window AC', ht = nil, znht = nil, cl = 'Electricity', cooled_zones)
|
627
585
|
standard.model_add_hvac_system(self, 'Forced Air Furnace', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones)
|
628
586
|
|
629
|
-
when '
|
587
|
+
when 'WindowAC_GasHeaters'
|
630
588
|
standard.model_add_hvac_system(self, 'Window AC', ht = nil, znht = nil, cl = 'Electricity', cooled_zones)
|
631
589
|
standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones)
|
632
590
|
|
633
|
-
when '
|
591
|
+
when 'WindowAC'
|
634
592
|
standard.model_add_hvac_system(self, 'Window AC', ht = nil, znht = nil, cl = 'Electricity', cooled_zones)
|
635
593
|
|
636
594
|
else
|