epb_view_models 2.1.8 → 2.2.0

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (202) hide show
  1. checksums.yaml +4 -4
  2. data/.buildspec.yml +1 -1
  3. data/api/schemas/data/orchestrate.json +4 -0
  4. data/api/schemas/xml/SAP-Schema-19.2.0/SAP/ExternalDefinitions.xml +1735 -0
  5. data/api/schemas/xml/SAP-Schema-19.2.0/SAP/ExternalDefinitions.xsd +313 -0
  6. data/api/schemas/xml/SAP-Schema-19.2.0/SAP/Templates/AssessorManagement.xsd +275 -0
  7. data/api/schemas/xml/SAP-Schema-19.2.0/SAP/Templates/EPC-Certificate.xsd +632 -0
  8. data/api/schemas/xml/SAP-Schema-19.2.0/SAP/Templates/ExceptionList.xsd +20 -0
  9. data/api/schemas/xml/SAP-Schema-19.2.0/SAP/Templates/Property.xsd +85 -0
  10. data/api/schemas/xml/SAP-Schema-19.2.0/SAP/Templates/ReportList.xsd +27 -0
  11. data/api/schemas/xml/SAP-Schema-19.2.0/SAP/Templates/SAP-CollectedData.xsd +2516 -0
  12. data/api/schemas/xml/SAP-Schema-19.2.0/SAP/Templates/SAP-Compliance-Report.xsd +51 -0
  13. data/api/schemas/xml/SAP-Schema-19.2.0/SAP/Templates/SAP-Report.xsd +277 -0
  14. data/api/schemas/xml/SAP-Schema-19.2.0/SAP/UDT/EPC-Domains.xsd +646 -0
  15. data/api/schemas/xml/SAP-Schema-19.2.0/SAP/UDT/SAP-Domains.xsd +3154 -0
  16. data/lib/epb_view_models.rb +1 -1
  17. data/lib/helper/xml_enums_to_output.rb +3 -0
  18. data/lib/view_model/factory.rb +1 -0
  19. data/lib/view_model/sap_schema_1920/common_schema.rb +600 -0
  20. data/lib/view_model/sap_wrapper.rb +2 -0
  21. metadata +20 -184
  22. data/api/schemas/xml/SAP-Schema-14.1/._CommonFiles +0 -0
  23. data/api/schemas/xml/SAP-Schema-14.1/._SAP-EPC +0 -0
  24. data/api/schemas/xml/SAP-Schema-14.1/._Templates +0 -0
  25. data/api/schemas/xml/SAP-Schema-14.1/CommonFiles/._CommonStructures.xsd +0 -0
  26. data/api/schemas/xml/SAP-Schema-14.1/Messages/._ConditionReportChangeAccessRequest_1.xsd +0 -0
  27. data/api/schemas/xml/SAP-Schema-14.1/Messages/._ConditionReportChangeAccessResponse_1.xsd +0 -0
  28. data/api/schemas/xml/SAP-Schema-14.1/Messages/._ConditionReportChangeStatusRequest_1.xsd +0 -0
  29. data/api/schemas/xml/SAP-Schema-14.1/Messages/._ConditionReportChangeStatusResponse_1.xsd +0 -0
  30. data/api/schemas/xml/SAP-Schema-14.1/Messages/._ConditionReportCreateRequest_1.xsd +0 -0
  31. data/api/schemas/xml/SAP-Schema-14.1/Messages/._ConditionReportRetrieveResponse_1.xsd +0 -0
  32. data/api/schemas/xml/SAP-Schema-14.1/Messages/._HomeInspectorRegisterUpdateRequest_1.xsd +0 -0
  33. data/api/schemas/xml/SAP-Schema-14.1/Messages/._HomeInspectorRegisterUpdateResponse_1.xsd +0 -0
  34. data/api/schemas/xml/SAP-Schema-14.1/Messages/._HomeInspectorRegisterUpdateStatusResponse_1.xsd +0 -0
  35. data/api/schemas/xml/SAP-Schema-14.1/Messages/._PropertyUPRNValidationResponse_1.xsd +0 -0
  36. data/api/schemas/xml/SAP-Schema-14.1/SAP-EPC/._Templates +0 -0
  37. data/api/schemas/xml/SAP-Schema-14.1/SAP-EPC/Templates/._EPC-Certificate.xsd +0 -0
  38. data/api/schemas/xml/SAP-Schema-14.1/SAP-EPC/Templates/._UserManagement.xsd +0 -0
  39. data/api/schemas/xml/SAP-Schema-14.1/SAP-EPC/UDT/._BaseDataTypes.xsd +0 -0
  40. data/api/schemas/xml/SAP-Schema-14.1/SAP-EPC/UDT/._SAP05-Domains.xsd +0 -0
  41. data/api/schemas/xml/SAP-Schema-14.1/Templates/._EPC-Certificate.xsd +0 -0
  42. data/api/schemas/xml/SAP-Schema-14.1/Templates/._EPC-CollectedData.xsd +0 -0
  43. data/api/schemas/xml/SAP-Schema-14.1/Templates/._HCR-FeaturesGrounds.xsd +0 -0
  44. data/api/schemas/xml/SAP-Schema-14.1/Templates/._HCR-PropertyDetails.xsd +0 -0
  45. data/api/schemas/xml/SAP-Schema-14.1/Templates/._HCR-RiskAssessment.xsd +0 -0
  46. data/api/schemas/xml/SAP-Schema-14.1/Templates/._HIP-Reports.xsd +0 -0
  47. data/api/schemas/xml/SAP-Schema-14.1/Templates/._UserManagement.xsd +0 -0
  48. data/api/schemas/xml/SAP-Schema-14.1/UDT/._BaseDataTypes.xsd +0 -0
  49. data/api/schemas/xml/SAP-Schema-14.1/UDT/._HCR-Domains.xsd +0 -0
  50. data/api/schemas/xml/SAP-Schema-14.1/UDT/._SAP-Domains.xsd +0 -0
  51. data/api/schemas/xml/SAP-Schema-14.1/UDT/._TypeDefinitions.xsd +0 -0
  52. data/api/schemas/xml/SAP-Schema-14.2/._CommonFiles +0 -0
  53. data/api/schemas/xml/SAP-Schema-14.2/._SAP-EPC +0 -0
  54. data/api/schemas/xml/SAP-Schema-14.2/._Templates +0 -0
  55. data/api/schemas/xml/SAP-Schema-14.2/CommonFiles/._CommonStructures.xsd +0 -0
  56. data/api/schemas/xml/SAP-Schema-14.2/Messages/._ConditionReportChangeAccessRequest_1.xsd +0 -0
  57. data/api/schemas/xml/SAP-Schema-14.2/Messages/._ConditionReportChangeAccessResponse_1.xsd +0 -0
  58. data/api/schemas/xml/SAP-Schema-14.2/Messages/._ConditionReportChangeStatusRequest_1.xsd +0 -0
  59. data/api/schemas/xml/SAP-Schema-14.2/Messages/._ConditionReportChangeStatusResponse_1.xsd +0 -0
  60. data/api/schemas/xml/SAP-Schema-14.2/Messages/._ConditionReportCreateRequest_1.xsd +0 -0
  61. data/api/schemas/xml/SAP-Schema-14.2/Messages/._ConditionReportRetrieveResponse_1.xsd +0 -0
  62. data/api/schemas/xml/SAP-Schema-14.2/Messages/._ExternalDefinitions.xml +0 -0
  63. data/api/schemas/xml/SAP-Schema-14.2/Messages/._ExternalDefinitions.xsd +0 -0
  64. data/api/schemas/xml/SAP-Schema-14.2/Messages/._HomeInspectorRegisterUpdateRequest_1.xsd +0 -0
  65. data/api/schemas/xml/SAP-Schema-14.2/Messages/._HomeInspectorRegisterUpdateResponse_1.xsd +0 -0
  66. data/api/schemas/xml/SAP-Schema-14.2/Messages/._HomeInspectorRegisterUpdateStatusResponse_1.xsd +0 -0
  67. data/api/schemas/xml/SAP-Schema-14.2/Messages/._PropertyUPRNValidationResponse_1.xsd +0 -0
  68. data/api/schemas/xml/SAP-Schema-14.2/SAP-EPC/._Templates +0 -0
  69. data/api/schemas/xml/SAP-Schema-14.2/SAP-EPC/Templates/._EPC-Certificate.xsd +0 -0
  70. data/api/schemas/xml/SAP-Schema-14.2/SAP-EPC/Templates/._UserManagement.xsd +0 -0
  71. data/api/schemas/xml/SAP-Schema-14.2/SAP-EPC/UDT/._BaseDataTypes.xsd +0 -0
  72. data/api/schemas/xml/SAP-Schema-14.2/SAP-EPC/UDT/._SAP05-Domains.xsd +0 -0
  73. data/api/schemas/xml/SAP-Schema-14.2/Templates/._EPC-Certificate.xsd +0 -0
  74. data/api/schemas/xml/SAP-Schema-14.2/Templates/._EPC-CollectedData.xsd +0 -0
  75. data/api/schemas/xml/SAP-Schema-14.2/Templates/._HCR-FeaturesGrounds.xsd +0 -0
  76. data/api/schemas/xml/SAP-Schema-14.2/Templates/._HCR-PropertyDetails.xsd +0 -0
  77. data/api/schemas/xml/SAP-Schema-14.2/Templates/._HCR-RiskAssessment.xsd +0 -0
  78. data/api/schemas/xml/SAP-Schema-14.2/Templates/._HIP-Reports.xsd +0 -0
  79. data/api/schemas/xml/SAP-Schema-14.2/Templates/._UserManagement.xsd +0 -0
  80. data/api/schemas/xml/SAP-Schema-14.2/UDT/._BaseDataTypes.xsd +0 -0
  81. data/api/schemas/xml/SAP-Schema-14.2/UDT/._HCR-Domains.xsd +0 -0
  82. data/api/schemas/xml/SAP-Schema-14.2/UDT/._SAP-Domains.xsd +0 -0
  83. data/api/schemas/xml/SAP-Schema-14.2/UDT/._TypeDefinitions.xsd +0 -0
  84. data/api/schemas/xml/SAP-Schema-15.0/._CommonFiles +0 -0
  85. data/api/schemas/xml/SAP-Schema-15.0/._SAP-EPC +0 -0
  86. data/api/schemas/xml/SAP-Schema-15.0/._Templates +0 -0
  87. data/api/schemas/xml/SAP-Schema-15.0/CommonFiles/._CommonStructures.xsd +0 -0
  88. data/api/schemas/xml/SAP-Schema-15.0/Messages/._ConditionReportChangeAccessRequest_1.xsd +0 -0
  89. data/api/schemas/xml/SAP-Schema-15.0/Messages/._ConditionReportChangeAccessResponse_1.xsd +0 -0
  90. data/api/schemas/xml/SAP-Schema-15.0/Messages/._ConditionReportChangeStatusRequest_1.xsd +0 -0
  91. data/api/schemas/xml/SAP-Schema-15.0/Messages/._ConditionReportChangeStatusResponse_1.xsd +0 -0
  92. data/api/schemas/xml/SAP-Schema-15.0/Messages/._ConditionReportCreateRequest_1.xsd +0 -0
  93. data/api/schemas/xml/SAP-Schema-15.0/Messages/._ConditionReportRetrieveResponse_1.xsd +0 -0
  94. data/api/schemas/xml/SAP-Schema-15.0/Messages/._ExternalDefinitions.xml +0 -0
  95. data/api/schemas/xml/SAP-Schema-15.0/Messages/._ExternalDefinitions.xsd +0 -0
  96. data/api/schemas/xml/SAP-Schema-15.0/Messages/._HomeInspectorRegisterUpdateRequest_1.xsd +0 -0
  97. data/api/schemas/xml/SAP-Schema-15.0/Messages/._HomeInspectorRegisterUpdateResponse_1.xsd +0 -0
  98. data/api/schemas/xml/SAP-Schema-15.0/Messages/._HomeInspectorRegisterUpdateStatusResponse_1.xsd +0 -0
  99. data/api/schemas/xml/SAP-Schema-15.0/Messages/._PropertyUPRNValidationResponse_1.xsd +0 -0
  100. data/api/schemas/xml/SAP-Schema-15.0/SAP-EPC/._Templates +0 -0
  101. data/api/schemas/xml/SAP-Schema-15.0/SAP-EPC/Templates/._EPC-Certificate.xsd +0 -0
  102. data/api/schemas/xml/SAP-Schema-15.0/SAP-EPC/Templates/._SAP09-Report.xsd +0 -0
  103. data/api/schemas/xml/SAP-Schema-15.0/SAP-EPC/Templates/._UserManagement.xsd +0 -0
  104. data/api/schemas/xml/SAP-Schema-15.0/SAP-EPC/UDT/._BaseDataTypes.xsd +0 -0
  105. data/api/schemas/xml/SAP-Schema-15.0/Templates/._EPC-Certificate.xsd +0 -0
  106. data/api/schemas/xml/SAP-Schema-15.0/Templates/._EPC-CollectedData.xsd +0 -0
  107. data/api/schemas/xml/SAP-Schema-15.0/Templates/._HCR-FeaturesGrounds.xsd +0 -0
  108. data/api/schemas/xml/SAP-Schema-15.0/Templates/._HCR-PropertyDetails.xsd +0 -0
  109. data/api/schemas/xml/SAP-Schema-15.0/Templates/._HCR-RiskAssessment.xsd +0 -0
  110. data/api/schemas/xml/SAP-Schema-15.0/Templates/._HIP-Reports.xsd +0 -0
  111. data/api/schemas/xml/SAP-Schema-15.0/Templates/._UserManagement.xsd +0 -0
  112. data/api/schemas/xml/SAP-Schema-15.0/UDT/._BaseDataTypes.xsd +0 -0
  113. data/api/schemas/xml/SAP-Schema-15.0/UDT/._HCR-Domains.xsd +0 -0
  114. data/api/schemas/xml/SAP-Schema-15.0/UDT/._SAP-Domains.xsd +0 -0
  115. data/api/schemas/xml/SAP-Schema-15.0/UDT/._TypeDefinitions.xsd +0 -0
  116. data/api/schemas/xml/SAP-Schema-16.0/._CommonFiles +0 -0
  117. data/api/schemas/xml/SAP-Schema-16.0/._SAP-EPC +0 -0
  118. data/api/schemas/xml/SAP-Schema-16.0/._Templates +0 -0
  119. data/api/schemas/xml/SAP-Schema-16.0/CommonFiles/._CommonStructures.xsd +0 -0
  120. data/api/schemas/xml/SAP-Schema-16.0/Messages/._Assessor.xsd +0 -0
  121. data/api/schemas/xml/SAP-Schema-16.0/Messages/._ConditionReportChangeAccessRequest_1.xsd +0 -0
  122. data/api/schemas/xml/SAP-Schema-16.0/Messages/._ConditionReportChangeAccessResponse_1.xsd +0 -0
  123. data/api/schemas/xml/SAP-Schema-16.0/Messages/._ConditionReportChangeStatusRequest_1.xsd +0 -0
  124. data/api/schemas/xml/SAP-Schema-16.0/Messages/._ConditionReportChangeStatusResponse_1.xsd +0 -0
  125. data/api/schemas/xml/SAP-Schema-16.0/Messages/._ConditionReportCreateRequest_1.xsd +0 -0
  126. data/api/schemas/xml/SAP-Schema-16.0/Messages/._ConditionReportRetrieveResponse_1.xsd +0 -0
  127. data/api/schemas/xml/SAP-Schema-16.0/Messages/._ExternalDefinitions.xml +0 -0
  128. data/api/schemas/xml/SAP-Schema-16.0/Messages/._ExternalDefinitions.xsd +0 -0
  129. data/api/schemas/xml/SAP-Schema-16.0/Messages/._PropertyUPRNValidationResponse_1.xsd +0 -0
  130. data/api/schemas/xml/SAP-Schema-16.0/SAP-EPC/._Templates +0 -0
  131. data/api/schemas/xml/SAP-Schema-16.0/SAP-EPC/Templates/._EPC-Certificate.xsd +0 -0
  132. data/api/schemas/xml/SAP-Schema-16.0/SAP-EPC/Templates/._SAP09-Report.xsd +0 -0
  133. data/api/schemas/xml/SAP-Schema-16.0/SAP-EPC/Templates/._UserManagement.xsd +0 -0
  134. data/api/schemas/xml/SAP-Schema-16.0/SAP-EPC/UDT/._BaseDataTypes.xsd +0 -0
  135. data/api/schemas/xml/SAP-Schema-16.0/Templates/._EPC-Certificate.xsd +0 -0
  136. data/api/schemas/xml/SAP-Schema-16.0/Templates/._EPC-CollectedData.xsd +0 -0
  137. data/api/schemas/xml/SAP-Schema-16.0/Templates/._HCR-FeaturesGrounds.xsd +0 -0
  138. data/api/schemas/xml/SAP-Schema-16.0/Templates/._HCR-PropertyDetails.xsd +0 -0
  139. data/api/schemas/xml/SAP-Schema-16.0/Templates/._HCR-RiskAssessment.xsd +0 -0
  140. data/api/schemas/xml/SAP-Schema-16.0/Templates/._HIP-Reports.xsd +0 -0
  141. data/api/schemas/xml/SAP-Schema-16.0/Templates/._UserManagement.xsd +0 -0
  142. data/api/schemas/xml/SAP-Schema-16.0/UDT/._BaseDataTypes.xsd +0 -0
  143. data/api/schemas/xml/SAP-Schema-16.0/UDT/._HCR-Domains.xsd +0 -0
  144. data/api/schemas/xml/SAP-Schema-16.0/UDT/._SAP-Domains.xsd +0 -0
  145. data/api/schemas/xml/SAP-Schema-16.0/UDT/._TypeDefinitions.xsd +0 -0
  146. data/api/schemas/xml/SAP-Schema-16.1/CommonFiles/._CommonStructures.xsd +0 -0
  147. data/api/schemas/xml/SAP-Schema-16.1/Messages/._Assessor.xsd +0 -0
  148. data/api/schemas/xml/SAP-Schema-16.1/Messages/._ConditionReportChangeAccessRequest_1.xsd +0 -0
  149. data/api/schemas/xml/SAP-Schema-16.1/Messages/._ConditionReportChangeAccessResponse_1.xsd +0 -0
  150. data/api/schemas/xml/SAP-Schema-16.1/Messages/._ConditionReportChangeStatusRequest_1.xsd +0 -0
  151. data/api/schemas/xml/SAP-Schema-16.1/Messages/._ConditionReportChangeStatusResponse_1.xsd +0 -0
  152. data/api/schemas/xml/SAP-Schema-16.1/Messages/._ConditionReportCreateRequest_1.xsd +0 -0
  153. data/api/schemas/xml/SAP-Schema-16.1/Messages/._ConditionReportRetrieveResponse_1.xsd +0 -0
  154. data/api/schemas/xml/SAP-Schema-16.1/Messages/._ExternalDefinitions.xml +0 -0
  155. data/api/schemas/xml/SAP-Schema-16.1/Messages/._ExternalDefinitions.xsd +0 -0
  156. data/api/schemas/xml/SAP-Schema-16.1/Messages/._PropertyUPRNValidationResponse_1.xsd +0 -0
  157. data/api/schemas/xml/SAP-Schema-16.1/SAP-EPC/._Templates +0 -0
  158. data/api/schemas/xml/SAP-Schema-16.1/SAP-EPC/Templates/._EPC-Certificate.xsd +0 -0
  159. data/api/schemas/xml/SAP-Schema-16.1/SAP-EPC/Templates/._SAP09-Report.xsd +0 -0
  160. data/api/schemas/xml/SAP-Schema-16.1/SAP-EPC/Templates/._UserManagement.xsd +0 -0
  161. data/api/schemas/xml/SAP-Schema-16.1/SAP-EPC/UDT/._BaseDataTypes.xsd +0 -0
  162. data/api/schemas/xml/SAP-Schema-16.1/Templates/._EPC-Certificate.xsd +0 -0
  163. data/api/schemas/xml/SAP-Schema-16.1/Templates/._EPC-CollectedData.xsd +0 -0
  164. data/api/schemas/xml/SAP-Schema-16.1/Templates/._HCR-FeaturesGrounds.xsd +0 -0
  165. data/api/schemas/xml/SAP-Schema-16.1/Templates/._HCR-PropertyDetails.xsd +0 -0
  166. data/api/schemas/xml/SAP-Schema-16.1/Templates/._HCR-RiskAssessment.xsd +0 -0
  167. data/api/schemas/xml/SAP-Schema-16.1/Templates/._HIP-Reports.xsd +0 -0
  168. data/api/schemas/xml/SAP-Schema-16.1/Templates/._UserManagement.xsd +0 -0
  169. data/api/schemas/xml/SAP-Schema-16.1/UDT/._BaseDataTypes.xsd +0 -0
  170. data/api/schemas/xml/SAP-Schema-16.1/UDT/._HCR-Domains.xsd +0 -0
  171. data/api/schemas/xml/SAP-Schema-16.1/UDT/._SAP-Domains.xsd +0 -0
  172. data/api/schemas/xml/SAP-Schema-16.1/UDT/._TypeDefinitions.xsd +0 -0
  173. data/api/schemas/xml/SAP-Schema-16.2/._CommonFiles +0 -0
  174. data/api/schemas/xml/SAP-Schema-16.2/._SAP-EPC +0 -0
  175. data/api/schemas/xml/SAP-Schema-16.2/._Templates +0 -0
  176. data/api/schemas/xml/SAP-Schema-16.2/CommonFiles/._CommonStructures.xsd +0 -0
  177. data/api/schemas/xml/SAP-Schema-16.2/Messages/._Assessor.xsd +0 -0
  178. data/api/schemas/xml/SAP-Schema-16.2/Messages/._ConditionReportChangeAccessRequest_1.xsd +0 -0
  179. data/api/schemas/xml/SAP-Schema-16.2/Messages/._ConditionReportChangeAccessResponse_1.xsd +0 -0
  180. data/api/schemas/xml/SAP-Schema-16.2/Messages/._ConditionReportChangeStatusRequest_1.xsd +0 -0
  181. data/api/schemas/xml/SAP-Schema-16.2/Messages/._ConditionReportChangeStatusResponse_1.xsd +0 -0
  182. data/api/schemas/xml/SAP-Schema-16.2/Messages/._ConditionReportCreateRequest_1.xsd +0 -0
  183. data/api/schemas/xml/SAP-Schema-16.2/Messages/._ConditionReportRetrieveResponse_1.xsd +0 -0
  184. data/api/schemas/xml/SAP-Schema-16.2/Messages/._ExternalDefinitions.xml +0 -0
  185. data/api/schemas/xml/SAP-Schema-16.2/Messages/._ExternalDefinitions.xsd +0 -0
  186. data/api/schemas/xml/SAP-Schema-16.2/Messages/._PropertyUPRNValidationResponse_1.xsd +0 -0
  187. data/api/schemas/xml/SAP-Schema-16.2/SAP-EPC/._Templates +0 -0
  188. data/api/schemas/xml/SAP-Schema-16.2/SAP-EPC/Templates/._EPC-Certificate.xsd +0 -0
  189. data/api/schemas/xml/SAP-Schema-16.2/SAP-EPC/Templates/._SAP09-Report.xsd +0 -0
  190. data/api/schemas/xml/SAP-Schema-16.2/SAP-EPC/Templates/._UserManagement.xsd +0 -0
  191. data/api/schemas/xml/SAP-Schema-16.2/SAP-EPC/UDT/._BaseDataTypes.xsd +0 -0
  192. data/api/schemas/xml/SAP-Schema-16.2/Templates/._EPC-Certificate.xsd +0 -0
  193. data/api/schemas/xml/SAP-Schema-16.2/Templates/._EPC-CollectedData.xsd +0 -0
  194. data/api/schemas/xml/SAP-Schema-16.2/Templates/._HCR-FeaturesGrounds.xsd +0 -0
  195. data/api/schemas/xml/SAP-Schema-16.2/Templates/._HCR-PropertyDetails.xsd +0 -0
  196. data/api/schemas/xml/SAP-Schema-16.2/Templates/._HCR-RiskAssessment.xsd +0 -0
  197. data/api/schemas/xml/SAP-Schema-16.2/Templates/._HIP-Reports.xsd +0 -0
  198. data/api/schemas/xml/SAP-Schema-16.2/Templates/._UserManagement.xsd +0 -0
  199. data/api/schemas/xml/SAP-Schema-16.2/UDT/._BaseDataTypes.xsd +0 -0
  200. data/api/schemas/xml/SAP-Schema-16.2/UDT/._HCR-Domains.xsd +0 -0
  201. data/api/schemas/xml/SAP-Schema-16.2/UDT/._SAP-Domains.xsd +0 -0
  202. data/api/schemas/xml/SAP-Schema-16.2/UDT/._TypeDefinitions.xsd +0 -0
@@ -0,0 +1,2516 @@
1
+ <?xml version="1.0" encoding="UTF-8"?>
2
+ <xs:schema
3
+ xmlns="https://epbr.digital.communities.gov.uk/xsd/sap"
4
+ xmlns:xs="http://www.w3.org/2001/XMLSchema"
5
+ targetNamespace="https://epbr.digital.communities.gov.uk/xsd/sap"
6
+ elementFormDefault="qualified"
7
+ attributeFormDefault="unqualified"
8
+ version="19.2.0"
9
+ >
10
+ <xs:include schemaLocation="../UDT/SAP-Domains.xsd"/>
11
+ <xs:include schemaLocation="../UDT/EPC-Domains.xsd"/>
12
+ <xs:element name="SAP-Deselected-Improvements"
13
+ type="SAP-Deselected-Improvements"/>
14
+ <xs:complexType name="SAP-Deselected-Improvements">
15
+ <xs:annotation>
16
+ <xs:documentation>There are 22 possible improvement measures, designated
17
+ from A to V. This must record measures deselected by DEA
18
+ (A to V is the full set, only E, N, U and V are considered at the moment
19
+ for new build).
20
+ </xs:documentation>
21
+ </xs:annotation>
22
+ <xs:sequence>
23
+ <xs:element name="Deselected-Improvement-Measure"
24
+ type="SAP-ImprovementMeasureCode" maxOccurs="unbounded"/>
25
+ </xs:sequence>
26
+ </xs:complexType>
27
+ <xs:element name="SAP-Wall" type="SAP-Wall"/>
28
+ <xs:complexType name="SAP-Wall">
29
+ <xs:annotation>
30
+ <xs:documentation>Various measurements for each wall of a particular
31
+ storey.
32
+ </xs:documentation>
33
+ </xs:annotation>
34
+ <xs:all>
35
+ <xs:element name="Name" type="xs:string">
36
+ <xs:annotation>
37
+ <xs:documentation>Unique name which identifies this wall within its
38
+ storey. Can be just a number, e.g. "1". However, a wall cannot have
39
+ the same name as an opening or a roof.
40
+ </xs:documentation>
41
+ </xs:annotation>
42
+ </xs:element>
43
+ <xs:element name="Description" type="Sentence" minOccurs="0">
44
+ <xs:annotation>
45
+ <xs:documentation>Descriptive notes about the wall.</xs:documentation>
46
+ </xs:annotation>
47
+ </xs:element>
48
+ <xs:element name="Wall-Type" type="SAP-WallTypeCode">
49
+ <xs:annotation>
50
+ <xs:documentation>Type of wall (exposure).</xs:documentation>
51
+ </xs:annotation>
52
+ </xs:element>
53
+ <xs:element name="Total-Wall-Area" type="Measurement">
54
+ <xs:annotation>
55
+ <xs:documentation>Total wall area in square metres, inclusive of any
56
+ openings.
57
+ </xs:documentation>
58
+ </xs:annotation>
59
+ </xs:element>
60
+ <xs:element name="U-Value" type="xs:decimal">
61
+ <xs:annotation>
62
+ <xs:documentation>Exposed wall U-value.</xs:documentation>
63
+ </xs:annotation>
64
+ </xs:element>
65
+ <xs:element name="Is-Curtain-Walling" type="xs:boolean" default="false"
66
+ minOccurs="0">
67
+ <xs:annotation>
68
+ <xs:documentation>Whether the wall is curtain walling, i.e. a facade
69
+ construction consisting of a frame of aluminium vertical and
70
+ horizontal members, infilled with glazing units and opaque panels.
71
+ </xs:documentation>
72
+ </xs:annotation>
73
+ </xs:element>
74
+ <xs:element name="Kappa-Value" type="xs:decimal" minOccurs="0">
75
+ <xs:annotation>
76
+ <xs:documentation>Heat capacity per unit area in kJ/m²K.
77
+ </xs:documentation>
78
+ </xs:annotation>
79
+ </xs:element>
80
+ </xs:all>
81
+ </xs:complexType>
82
+ <xs:element name="SAP-Roof" type="SAP-Roof"/>
83
+ <xs:complexType name="SAP-Roof">
84
+ <xs:annotation>
85
+ <xs:documentation>Various measurements for each exposed roof that makes up
86
+ a particular Building-Part.
87
+ </xs:documentation>
88
+ </xs:annotation>
89
+ <xs:all>
90
+ <xs:element name="Name" type="xs:string">
91
+ <xs:annotation>
92
+ <xs:documentation>Unique name which identifies this roof. Can be just
93
+ a number, e.g. "1". However, a roof cannot have the same name as a
94
+ wall.
95
+ </xs:documentation>
96
+ </xs:annotation>
97
+ </xs:element>
98
+ <xs:element name="Description" type="Sentence" minOccurs="0">
99
+ <xs:annotation>
100
+ <xs:documentation>Descriptive notes about the roof.</xs:documentation>
101
+ </xs:annotation>
102
+ </xs:element>
103
+ <xs:element name="Roof-Type" type="SAP-RoofTypeCode"/>
104
+ <xs:element name="Total-Roof-Area" type="Measurement">
105
+ <xs:annotation>
106
+ <xs:documentation>Total roof area in square metres, inclusive of any
107
+ openings.
108
+ </xs:documentation>
109
+ </xs:annotation>
110
+ </xs:element>
111
+ <xs:element name="U-Value" type="xs:decimal">
112
+ <xs:annotation>
113
+ <xs:documentation>Exposed roof U-value.</xs:documentation>
114
+ </xs:annotation>
115
+ </xs:element>
116
+ <xs:element name="Kappa-Value" type="xs:decimal" minOccurs="0">
117
+ <xs:annotation>
118
+ <xs:documentation>Heat capacity per unit area in kJ/m²K.
119
+ </xs:documentation>
120
+ </xs:annotation>
121
+ </xs:element>
122
+ </xs:all>
123
+ </xs:complexType>
124
+ <xs:element name="SAP-Community-Heating-Systems"
125
+ type="SAP-Community-Heating-Systems"/>
126
+ <xs:complexType name="SAP-Community-Heating-Systems">
127
+ <xs:annotation>
128
+ <xs:documentation>Community heating systems used by the property.
129
+ </xs:documentation>
130
+ </xs:annotation>
131
+ <xs:sequence>
132
+ <xs:element name="SAP-Community-Heating-System"
133
+ type="SAP-Community-Heating-System" maxOccurs="2"/>
134
+ </xs:sequence>
135
+ </xs:complexType>
136
+ <xs:element name="SAP-Thermal-Bridge" type="SAP-Thermal-Bridge"/>
137
+ <xs:complexType name="SAP-Thermal-Bridge">
138
+ <xs:annotation>
139
+ <xs:documentation>Various measurements for each thermal bridge that makes
140
+ up a particular Building-Part.
141
+ </xs:documentation>
142
+ </xs:annotation>
143
+ <xs:all>
144
+ <xs:element name="Thermal-Bridge-Type" type="SAP-ThermalBridgeTypeCode">
145
+ <xs:annotation>
146
+ <xs:documentation>Code to indicate a particular type of thermal
147
+ bridge; only if thermal bridge code is: user defined (individual
148
+ values).
149
+ </xs:documentation>
150
+ </xs:annotation>
151
+ </xs:element>
152
+ <xs:element name="Length" type="Measurement">
153
+ <xs:annotation>
154
+ <xs:documentation>Length of the thermal bridge in metres; only if
155
+ thermal bridge code is: user defined (individual values).
156
+ </xs:documentation>
157
+ </xs:annotation>
158
+ </xs:element>
159
+ <xs:element name="Psi-Value" type="Measurement">
160
+ <xs:annotation>
161
+ <xs:documentation>Linear thermal transmittance (psi-value); only if
162
+ thermal bridging is user defined individual values.
163
+ </xs:documentation>
164
+ </xs:annotation>
165
+ </xs:element>
166
+ <xs:element name="Psi-Value-Source" type="PsiValueSourceCode"/>
167
+ <xs:element name="Psi-Value-Calculation-Reference" type="xs:string"
168
+ minOccurs="0">
169
+ <xs:annotation>
170
+ <xs:documentation>Reference to the details of the calculation of the
171
+ psi-value.
172
+ </xs:documentation>
173
+ </xs:annotation>
174
+ </xs:element>
175
+ </xs:all>
176
+ </xs:complexType>
177
+ <xs:element name="SAP-Opening" type="SAP-Opening"/>
178
+ <xs:complexType name="SAP-Opening">
179
+ <xs:annotation>
180
+ <xs:documentation>Various measurements for each exposed opening that makes
181
+ up a particular Building-Part.
182
+ </xs:documentation>
183
+ </xs:annotation>
184
+ <xs:all>
185
+ <xs:element name="Name" type="xs:string">
186
+ <xs:annotation>
187
+ <xs:documentation>Unique name which identifies this opening. Can be
188
+ just a number, e.g. "1". However, an opening cannot have the same
189
+ name as a wall.
190
+ </xs:documentation>
191
+ </xs:annotation>
192
+ </xs:element>
193
+ <xs:element name="Type" type="xs:string">
194
+ <xs:annotation>
195
+ <xs:documentation>The name of the SAP-Opening-Type for this opening.
196
+ </xs:documentation>
197
+ </xs:annotation>
198
+ </xs:element>
199
+ <xs:element name="Location" type="xs:string">
200
+ <xs:annotation>
201
+ <xs:documentation>Name of the wall or roof which contains the
202
+ opening.
203
+ </xs:documentation>
204
+ </xs:annotation>
205
+ </xs:element>
206
+ <xs:element name="Orientation" type="SAP-OrientationCode">
207
+ <xs:annotation>
208
+ <xs:documentation>Compass direction in which the opening faces.
209
+ </xs:documentation>
210
+ </xs:annotation>
211
+ </xs:element>
212
+ <xs:element name="Width" type="Measurement">
213
+ <xs:annotation>
214
+ <xs:documentation>The width of the opening in metres. If the Width
215
+ field is used to record the opening area, set the Height to 1.
216
+ </xs:documentation>
217
+ </xs:annotation>
218
+ </xs:element>
219
+ <xs:element name="Height" type="Measurement">
220
+ <xs:annotation>
221
+ <xs:documentation>The height of the opening in metres. If the Height
222
+ field is used to record the opening area, set the Width to 1.
223
+ </xs:documentation>
224
+ </xs:annotation>
225
+ </xs:element>
226
+ <xs:element name="Pitch" type="SAP-VerticalPitch" minOccurs="0">
227
+ <xs:annotation>
228
+ <xs:documentation>Pitch of roof containing roof window.
229
+ </xs:documentation>
230
+ </xs:annotation>
231
+ </xs:element>
232
+ </xs:all>
233
+ </xs:complexType>
234
+ <xs:element name="SAP-Openings" type="SAP-Openings"/>
235
+ <xs:complexType name="SAP-Openings">
236
+ <xs:annotation>
237
+ <xs:documentation>Exposed openings that make up a particular
238
+ Building-Part.
239
+ </xs:documentation>
240
+ </xs:annotation>
241
+ <xs:sequence>
242
+ <xs:element name="SAP-Opening" type="SAP-Opening" maxOccurs="unbounded"/>
243
+ </xs:sequence>
244
+ </xs:complexType>
245
+ <xs:element name="SAP-Roofs" type="SAP-Roofs"/>
246
+ <xs:complexType name="SAP-Roofs">
247
+ <xs:annotation>
248
+ <xs:documentation>Exposed roofs that make up a particular Building-Part.
249
+ </xs:documentation>
250
+ </xs:annotation>
251
+ <xs:sequence>
252
+ <xs:element name="SAP-Roof" type="SAP-Roof" maxOccurs="unbounded"/>
253
+ </xs:sequence>
254
+ </xs:complexType>
255
+ <xs:element name="SAP-Community-Heating-System"
256
+ type="SAP-Community-Heating-System"/>
257
+ <xs:complexType name="SAP-Community-Heating-System">
258
+ <xs:annotation>
259
+ <xs:documentation>Details of a community system which heats the Main
260
+ Building.
261
+ </xs:documentation>
262
+ </xs:annotation>
263
+ <xs:all>
264
+ <xs:element name="Community-Heating-Name" type="xs:string" minOccurs="0">
265
+ <xs:annotation>
266
+ <xs:documentation>The name of the community heating system
267
+ </xs:documentation>
268
+ </xs:annotation>
269
+ </xs:element>
270
+ <xs:element name="Community-Heating-CO2-Emission-Factor" type="xs:decimal"
271
+ minOccurs="0">
272
+ <xs:annotation>
273
+ <xs:documentation>the community heating CO2 emission factor
274
+ </xs:documentation>
275
+ </xs:annotation>
276
+ </xs:element>
277
+ <xs:element name="Community-Heating-Primary-Energy-Factor"
278
+ type="xs:decimal" minOccurs="0">
279
+ <xs:annotation>
280
+ <xs:documentation>The community heating Primary Energy Factor
281
+ </xs:documentation>
282
+ </xs:annotation>
283
+ </xs:element>
284
+ <xs:element name="Community-Heating-Use"
285
+ type="SAP-CommunityHeatingUseCode">
286
+ <xs:annotation>
287
+ <xs:documentation>Specifies what kind of heating the community system
288
+ is used for.
289
+ </xs:documentation>
290
+ </xs:annotation>
291
+ </xs:element>
292
+ <xs:element name="Is-Community-Heating-Cylinder-In-Dwelling"
293
+ type="xs:boolean" default="false" minOccurs="0">
294
+ <xs:annotation>
295
+ <xs:documentation>Community heating, cylinder in dwelling?
296
+ </xs:documentation>
297
+ </xs:annotation>
298
+ </xs:element>
299
+ <xs:element name="Is-HIU-In-Dwelling" type="xs:boolean" default="false"
300
+ minOccurs="0">
301
+ <xs:annotation>
302
+ <xs:documentation>Community heating, HIU in dwelling?
303
+ </xs:documentation>
304
+ </xs:annotation>
305
+ </xs:element>
306
+ <xs:element name="HIU-Index-Number" type="xs:positiveInteger"
307
+ minOccurs="0">
308
+ <xs:annotation>
309
+ <xs:documentation>Heat Interface Unit index number, if present.
310
+ </xs:documentation>
311
+ </xs:annotation>
312
+ </xs:element>
313
+ <xs:element name="Community-Heating-Distribution-Type"
314
+ type="SAP-HeatingDistributionCode" minOccurs="0">
315
+ <xs:annotation>
316
+ <xs:documentation>Community heating distribution</xs:documentation>
317
+ </xs:annotation>
318
+ </xs:element>
319
+ <xs:element name="Community-Heat-Sources" type="Community-Heat-Sources"
320
+ minOccurs="0">
321
+ <xs:annotation>
322
+ <xs:documentation>To be provided when there is no
323
+ Heat-Network-Index-Number.
324
+ </xs:documentation>
325
+ </xs:annotation>
326
+ </xs:element>
327
+ <xs:element name="Community-Heating-Distribution-Loss-Factor"
328
+ type="xs:decimal" minOccurs="0">
329
+ <xs:annotation>
330
+ <xs:documentation>Used when Community-Heating-Distribution-Type is
331
+ calculated.
332
+ </xs:documentation>
333
+ </xs:annotation>
334
+ </xs:element>
335
+ <xs:element name="Charging-Linked-To-Heat-Use" type="xs:boolean"
336
+ minOccurs="0">
337
+ <xs:annotation>
338
+ <xs:documentation>Used for hot-water-only systems.</xs:documentation>
339
+ </xs:annotation>
340
+ </xs:element>
341
+ <xs:element name="Heat-Network-Index-Number" type="xs:positiveInteger"
342
+ minOccurs="0">
343
+ <xs:annotation>
344
+ <xs:documentation>Index number of heat network, if applicable.
345
+ </xs:documentation>
346
+ </xs:annotation>
347
+ </xs:element>
348
+ <xs:element name="Sub-Network-Name" type="xs:string" minOccurs="0">
349
+ <xs:annotation>
350
+ <xs:documentation>The name by which the sub community heat network is known.</xs:documentation>
351
+ </xs:annotation>
352
+ </xs:element>
353
+ <xs:element name="Heat-Network-Existing" type="xs:boolean" default="true" minOccurs="0">
354
+ <xs:annotation>
355
+ <xs:documentation>Whether the heat network is existing or new.</xs:documentation>
356
+ </xs:annotation>
357
+ </xs:element>
358
+ <xs:element name="Heat-Network-Sleeved" type="xs:boolean" default="true" minOccurs="0">
359
+ <xs:annotation>
360
+ <xs:documentation>Whether the heat network is sleeved.</xs:documentation>
361
+ </xs:annotation>
362
+ </xs:element>
363
+ <xs:element name="Heat-Network-Community-Heating" type="xs:boolean" default="true" minOccurs="0">
364
+ <xs:annotation>
365
+ <xs:documentation>Whether the heat network is defined as community heating.</xs:documentation>
366
+ </xs:annotation>
367
+ </xs:element>
368
+ <xs:element name="Heat-Network-Assessed-As-New" type="xs:boolean" default="false" minOccurs="0">
369
+ <xs:annotation>
370
+ <xs:documentation>Whether the heat network is assessed as a new heat
371
+ network (post June 2022) for Eng with a standalone gas boiler
372
+ notional building.
373
+ </xs:documentation>
374
+ </xs:annotation>
375
+ </xs:element>
376
+ </xs:all>
377
+ </xs:complexType>
378
+ <xs:element name="SAP-Floor-Dimensions" type="SAP-Floor-Dimensions"/>
379
+ <xs:complexType name="SAP-Floor-Dimensions">
380
+ <xs:annotation>
381
+ <xs:documentation>Storeys that make up a particular Building-Part.
382
+ </xs:documentation>
383
+ </xs:annotation>
384
+ <xs:sequence>
385
+ <xs:element name="SAP-Floor-Dimension" type="SAP-Floor-Dimension"
386
+ maxOccurs="unbounded"/>
387
+ </xs:sequence>
388
+ </xs:complexType>
389
+ <xs:element name="SAP-Thermal-Bridges" type="SAP-Thermal-Bridges"/>
390
+ <xs:complexType name="SAP-Thermal-Bridges">
391
+ <xs:annotation>
392
+ <xs:documentation>Thermal bridges that make up a particular
393
+ Building-Part.
394
+ </xs:documentation>
395
+ </xs:annotation>
396
+ <xs:sequence>
397
+ <xs:element name="Thermal-Bridge-Code" type="SAP-ThermalBridgeCode">
398
+ <xs:annotation>
399
+ <xs:documentation>Code which indicates how the thermal bridge data has
400
+ been recorded.
401
+ </xs:documentation>
402
+ </xs:annotation>
403
+ </xs:element>
404
+ <xs:element name="User-Defined-Y-Value" type="Measurement" minOccurs="0">
405
+ <xs:annotation>
406
+ <xs:documentation>Global y-value for all thermal bridges in watts per
407
+ square metre per kelvin; only if thermal bridge code is: user
408
+ defined (global y-value)
409
+ </xs:documentation>
410
+ </xs:annotation>
411
+ </xs:element>
412
+ <xs:element name="Calculation-Reference" type="xs:string" minOccurs="0">
413
+ <xs:annotation>
414
+ <xs:documentation>Reference to the details of the calculation of the
415
+ global y-value; only if thermal bridging is user defined global
416
+ y-value.
417
+ </xs:documentation>
418
+ </xs:annotation>
419
+ </xs:element>
420
+ <xs:element name="SAP-Thermal-Bridge" type="SAP-Thermal-Bridge"
421
+ minOccurs="0" maxOccurs="unbounded"/>
422
+ </xs:sequence>
423
+ </xs:complexType>
424
+ <xs:element name="SAP-Walls" type="SAP-Walls"/>
425
+ <xs:complexType name="SAP-Walls">
426
+ <xs:annotation>
427
+ <xs:documentation>Exposed walls that make up a particular Storey.
428
+ </xs:documentation>
429
+ </xs:annotation>
430
+ <xs:sequence>
431
+ <xs:element name="SAP-Wall" type="SAP-Wall" maxOccurs="unbounded"/>
432
+ </xs:sequence>
433
+ </xs:complexType>
434
+ <xs:element name="SAP-Opening-Type" type="SAP-Opening-Type"/>
435
+ <xs:complexType name="SAP-Opening-Type">
436
+ <xs:annotation>
437
+ <xs:documentation>Various measurements for a particular type of exposed
438
+ opening that makes up a particular property. Opening types are used to
439
+ capture common features shared by multiple openings, to avoid having to
440
+ record the same data explicitly for each opening.
441
+ </xs:documentation>
442
+ </xs:annotation>
443
+ <xs:all>
444
+ <xs:element name="Name" type="xs:string">
445
+ <xs:annotation>
446
+ <xs:documentation>Unique name which identifies this opening type. Can
447
+ be just a number, e.g. "1".
448
+ </xs:documentation>
449
+ </xs:annotation>
450
+ </xs:element>
451
+ <xs:element name="Description" type="Sentence" minOccurs="0">
452
+ <xs:annotation>
453
+ <xs:documentation>Descriptive notes about the opening type.
454
+ </xs:documentation>
455
+ </xs:annotation>
456
+ </xs:element>
457
+ <xs:element name="Data-Source" type="SAP-OpeningDataSourceCode">
458
+ <xs:annotation>
459
+ <xs:documentation>The source of the data for this type of opening.
460
+ </xs:documentation>
461
+ </xs:annotation>
462
+ </xs:element>
463
+ <xs:element name="Type" type="SAP-OpeningTypeCode">
464
+ <xs:annotation>
465
+ <xs:documentation>The (physical) type of opening that this opening
466
+ type represents.
467
+ </xs:documentation>
468
+ </xs:annotation>
469
+ </xs:element>
470
+ <xs:element name="Glazing-Type" type="SAP-GlazingTypeCode" minOccurs="0">
471
+ <xs:annotation>
472
+ <xs:documentation>The type of glazing; if U-value is from BFRC or
473
+ manufacturer declaration, give as one of
474
+ - single
475
+ - double
476
+ - triple.
477
+ </xs:documentation>
478
+ </xs:annotation>
479
+ </xs:element>
480
+ <xs:element name="Glazing-Gap" type="SAP-GlazingGapTypeCode"
481
+ minOccurs="0">
482
+ <xs:annotation>
483
+ <xs:documentation>Gap between glass panes; only if SAP table and
484
+ double, triple glazed or secondary glazing.
485
+ </xs:documentation>
486
+ </xs:annotation>
487
+ </xs:element>
488
+ <xs:element name="IsArgonFilled" type="xs:boolean" default="false"
489
+ minOccurs="0">
490
+ <xs:annotation>
491
+ <xs:documentation>Is the opening argon-filled? Only if SAP table.
492
+ </xs:documentation>
493
+ </xs:annotation>
494
+ </xs:element>
495
+ <xs:element name="IsKryptonFilled" type="xs:boolean" default="false"
496
+ minOccurs="0">
497
+ <xs:annotation>
498
+ <xs:documentation>Is the opening krypton-filled? Only if SAP table.
499
+ </xs:documentation>
500
+ </xs:annotation>
501
+ </xs:element>
502
+ <xs:element name="Frame-Type" type="SAP-FrameTypeCode" minOccurs="0">
503
+ <xs:annotation>
504
+ <xs:documentation>The type of frame, only if data source is SAP table
505
+ and it is a window, roof window or half-glazed door.
506
+ </xs:documentation>
507
+ </xs:annotation>
508
+ </xs:element>
509
+ <xs:element name="Solar-Transmittance" type="xs:decimal" minOccurs="0">
510
+ <xs:annotation>
511
+ <xs:documentation>The solar transmittance; not if a door.
512
+ </xs:documentation>
513
+ </xs:annotation>
514
+ </xs:element>
515
+ <xs:element name="Frame-Factor" type="xs:decimal" minOccurs="0">
516
+ <xs:annotation>
517
+ <xs:documentation>The frame factor; not if a door.</xs:documentation>
518
+ </xs:annotation>
519
+ </xs:element>
520
+ <xs:element name="U-Value" type="xs:decimal">
521
+ <xs:annotation>
522
+ <xs:documentation>The U-value. For rooflights, the U-value should be
523
+ in the horizontal plane.
524
+ </xs:documentation>
525
+ </xs:annotation>
526
+ </xs:element>
527
+ </xs:all>
528
+ </xs:complexType>
529
+ <xs:element name="SAP-Opening-Types" type="SAP-Opening-Types"/>
530
+ <xs:complexType name="SAP-Opening-Types">
531
+ <xs:annotation>
532
+ <xs:documentation>Types of exposed openings that make up a particular
533
+ property. Opening types are used to capture common features shared by
534
+ multiple openings, to avoid having to record the same data explicitly
535
+ for each opening.
536
+ </xs:documentation>
537
+ </xs:annotation>
538
+ <xs:sequence>
539
+ <xs:element name="SAP-Opening-Type" type="SAP-Opening-Type"
540
+ maxOccurs="unbounded"/>
541
+ </xs:sequence>
542
+ </xs:complexType>
543
+ <xs:element name="SAP-Ventilation" type="SAP-Ventilation"/>
544
+ <xs:complexType name="SAP-Ventilation">
545
+ <xs:annotation>
546
+ <xs:documentation>Details of the means by which the building is
547
+ ventilated
548
+ </xs:documentation>
549
+ </xs:annotation>
550
+ <xs:all>
551
+ <xs:element name="Closed-Flues-Count" type="Count">
552
+ <xs:annotation>
553
+ <xs:documentation>The number of Closed Flues or chimneys in the
554
+ Property.
555
+ </xs:documentation>
556
+ </xs:annotation>
557
+ </xs:element>
558
+ <xs:element name="Open-Flues-Count" type="Count">
559
+ <xs:annotation>
560
+ <xs:documentation>The number of Open Flues in the Property.
561
+ </xs:documentation>
562
+ </xs:annotation>
563
+ </xs:element>
564
+ <xs:element name="Boilers-Flues-Count" type="Count">
565
+ <xs:annotation>
566
+ <xs:documentation>The number of Boiler Flues or chimneys in the
567
+ Property.
568
+ </xs:documentation>
569
+ </xs:annotation>
570
+ </xs:element>
571
+ <xs:element name="Other-Flues-Count" type="Count">
572
+ <xs:annotation>
573
+ <xs:documentation>The number of Other Flues or chimneys in the
574
+ Property.
575
+ </xs:documentation>
576
+ </xs:annotation>
577
+ </xs:element>
578
+ <xs:element name="Open-Chimneys-Count" type="Count">
579
+ <xs:annotation>
580
+ <xs:documentation>The number of Open Chimneys in the Property.
581
+ </xs:documentation>
582
+ </xs:annotation>
583
+ </xs:element>
584
+ <xs:element name="Blocked-Chimneys-Count" type="Count">
585
+ <xs:annotation>
586
+ <xs:documentation>The number of Blocked Chimneys in the Property.
587
+ </xs:documentation>
588
+ </xs:annotation>
589
+ </xs:element>
590
+ <xs:element name="Fans-Vents-Count" type="Count" minOccurs="0">
591
+ <xs:annotation>
592
+ <xs:documentation>For backward compatibility only, do not use.
593
+ </xs:documentation>
594
+ </xs:annotation>
595
+ </xs:element>
596
+ <xs:element name="Flueless-Gas-Fires-Count" type="Count">
597
+ <xs:annotation>
598
+ <xs:documentation>The number of flueless gas fires in the Property.
599
+ </xs:documentation>
600
+ </xs:annotation>
601
+ </xs:element>
602
+ <xs:element name="Pressure-Test" type="SAP-PressureTestCode">
603
+ <xs:annotation>
604
+ <xs:documentation>Whether there has been a pressure test, or whether
605
+ an assumed value is used for the air permeability.
606
+ </xs:documentation>
607
+ </xs:annotation>
608
+ </xs:element>
609
+ <xs:element name="Pressure-Test-Certificate-Number" type="xs:string"
610
+ minOccurs="0">
611
+ <xs:annotation>
612
+ <xs:documentation>The pressure test certificate number or test
613
+ engineer reference.
614
+ </xs:documentation>
615
+ </xs:annotation>
616
+ </xs:element>
617
+ <xs:element name="Air-Permeability" type="xs:decimal" minOccurs="0">
618
+ <xs:annotation>
619
+ <xs:documentation>Air permeability; only if pressure test (yes or
620
+ assumed).
621
+ </xs:documentation>
622
+ </xs:annotation>
623
+ </xs:element>
624
+ <xs:element name="Ground-Floor-Type" type="SAP-FloorConstructionCode"
625
+ minOccurs="0">
626
+ <xs:annotation>
627
+ <xs:documentation>The type of ground floor; nly if no pressure test.
628
+ </xs:documentation>
629
+ </xs:annotation>
630
+ </xs:element>
631
+ <xs:element name="Wall-Type" type="SAP-WallConstructionCode"
632
+ minOccurs="0">
633
+ <xs:annotation>
634
+ <xs:documentation>The construction of the walls; only if no pressure
635
+ test.
636
+ </xs:documentation>
637
+ </xs:annotation>
638
+ </xs:element>
639
+ <xs:element name="Has-Draught-Lobby" type="xs:boolean" default="false"
640
+ minOccurs="0">
641
+ <xs:annotation>
642
+ <xs:documentation>Is there a draft lobby? Only if no pressure test.
643
+ </xs:documentation>
644
+ </xs:annotation>
645
+ </xs:element>
646
+ <xs:element name="DraughtStripping" type="Percentage" minOccurs="0">
647
+ <xs:annotation>
648
+ <xs:documentation>Draughtstripping percentage; only if no pressure
649
+ test.
650
+ </xs:documentation>
651
+ </xs:annotation>
652
+ </xs:element>
653
+ <xs:element name="Sheltered-Sides-Count" type="Count">
654
+ <xs:annotation>
655
+ <xs:documentation>The number of sheltered sides in the Property.
656
+ </xs:documentation>
657
+ </xs:annotation>
658
+ </xs:element>
659
+ <xs:element name="Ventilation-Type" type="SAP-VentilationTypeCode">
660
+ <xs:annotation>
661
+ <xs:documentation>The type of ventilation.</xs:documentation>
662
+ </xs:annotation>
663
+ </xs:element>
664
+ <xs:element name="Mechanical-Ventilation-Data-Source"
665
+ type="SAP-DataSourceCode" minOccurs="0">
666
+ <xs:annotation>
667
+ <xs:documentation>Source of mechanical ventilation data; only if
668
+ mechanical ventilation.
669
+ </xs:documentation>
670
+ </xs:annotation>
671
+ </xs:element>
672
+ <xs:element name="Mechanical-Vent-System-Index-Number"
673
+ type="xs:nonNegativeInteger" minOccurs="0">
674
+ <xs:annotation>
675
+ <xs:documentation>Mechanical vent system index number; if mechanical
676
+ vent data from database (MEV c, MEV dc, MV, MVHR).
677
+ </xs:documentation>
678
+ </xs:annotation>
679
+ </xs:element>
680
+ <xs:element name="Mechanical-Vent-Commissioning-Certificate-Number"
681
+ type="xs:string" minOccurs="0">
682
+ <xs:annotation>
683
+ <xs:documentation>Mechanical ventilation Commissioning certificate
684
+ number .
685
+ </xs:documentation>
686
+ </xs:annotation>
687
+ </xs:element>
688
+ <xs:element name="Mechanical-Vent-Installation-Engineer" type="xs:string"
689
+ minOccurs="0">
690
+ <xs:annotation>
691
+ <xs:documentation>Mechanical ventilation installation engineer
692
+ registration reference.
693
+ </xs:documentation>
694
+ </xs:annotation>
695
+ </xs:element>
696
+ <xs:element name="Mechanical-Vent-System-Make-Model" type="xs:string"
697
+ minOccurs="0">
698
+ <xs:annotation>
699
+ <xs:documentation>Mechanical ventilation system make and model.
700
+ </xs:documentation>
701
+ </xs:annotation>
702
+ </xs:element>
703
+ <xs:element name="Wet-Rooms-Count" type="NonZeroCount" minOccurs="0">
704
+ <xs:annotation>
705
+ <xs:documentation>Number of wet rooms, including the kitchen; if mech
706
+ vent data from manufacturer declaration or database (MEV c, MV,
707
+ MVHR).
708
+ </xs:documentation>
709
+ </xs:annotation>
710
+ </xs:element>
711
+ <xs:element name="Mechanical-Vent-Specific-Fan-Power" type="Measurement"
712
+ minOccurs="0">
713
+ <xs:annotation>
714
+ <xs:documentation>Mechanical vent specific fan power in watts per
715
+ (litres per second); if mechanical vent data (PIV from outside, MEV
716
+ c or dc, MV, MVHR).
717
+ </xs:documentation>
718
+ </xs:annotation>
719
+ </xs:element>
720
+ <xs:element name="Mechanical-Vent-Heat-Recovery-Efficiency"
721
+ type="Percentage" minOccurs="0">
722
+ <xs:annotation>
723
+ <xs:documentation>Mechanical vent heat recovery efficiency percentage;
724
+ if mechanical vent (MVHR).
725
+ </xs:documentation>
726
+ </xs:annotation>
727
+ </xs:element>
728
+ <xs:element name="Mechanical-Vent-Duct-Type" type="SAP-DuctTypeCode"
729
+ minOccurs="0">
730
+ <xs:annotation>
731
+ <xs:documentation>Mechanical vent duct type; if MEV c, MV or MVHR.
732
+ </xs:documentation>
733
+ </xs:annotation>
734
+ </xs:element>
735
+ <xs:element name="Mechanical-Vent-Duct-Insulation"
736
+ type="SAP-DuctInsulationCode" minOccurs="0">
737
+ <xs:annotation>
738
+ <xs:documentation>Mechanical vent duct insulation; if MVHR.
739
+ </xs:documentation>
740
+ </xs:annotation>
741
+ </xs:element>
742
+ <xs:element name="Mechanical-Vent-Duct-Insulation-Level"
743
+ type="SAP-DuctInsulationLevel" minOccurs="0">
744
+ <xs:annotation>
745
+ <xs:documentation>Mechanical vent duct insulation; if MVHR.
746
+ </xs:documentation>
747
+ </xs:annotation>
748
+ </xs:element>
749
+ <xs:element name="Mechanical-Vent-Duct-Placement" type="SAP-DuctPlacement"
750
+ minOccurs="0">
751
+ <xs:annotation>
752
+ <xs:documentation>Mechanical ventilation duct insulation; if MVHR.
753
+ </xs:documentation>
754
+ </xs:annotation>
755
+ </xs:element>
756
+ <xs:element name="Mechanical-Vent-Measured-Installation" type="xs:boolean"
757
+ minOccurs="0">
758
+ <xs:annotation>
759
+ <xs:documentation>Mechanical ventilation SPF measured in situ; if MVHR
760
+ or balanced.
761
+ </xs:documentation>
762
+ </xs:annotation>
763
+ </xs:element>
764
+ <xs:element name="Kitchen-Room-Fans-Count" type="Count" minOccurs="0">
765
+ <xs:annotation>
766
+ <xs:documentation>MEV dc, number of fans in room, kitchen; if
767
+ mechanical vent data from database or manufacturer declaration (MEV
768
+ dc).
769
+ </xs:documentation>
770
+ </xs:annotation>
771
+ </xs:element>
772
+ <xs:element name="Kitchen-Room-Fans-Specific-Power" type="Measurement"
773
+ minOccurs="0">
774
+ <xs:annotation>
775
+ <xs:documentation>MEV dc, specific fan power of fans in room, kitchen,
776
+ in watts per (litres per second); if mechanical vent data from
777
+ manufacturer declaration (MEV dc).
778
+ </xs:documentation>
779
+ </xs:annotation>
780
+ </xs:element>
781
+ <xs:element name="Non-Kitchen-Room-Fans-Count" type="Count" minOccurs="0">
782
+ <xs:annotation>
783
+ <xs:documentation>MEV dc, number of fans in room, rooms other than
784
+ kitchen; if mechanical vent data from database or manufacturer
785
+ declaration (MEV dc).
786
+ </xs:documentation>
787
+ </xs:annotation>
788
+ </xs:element>
789
+ <xs:element name="Non-Kitchen-Room-Fans-Specific-Power" type="Measurement"
790
+ minOccurs="0">
791
+ <xs:annotation>
792
+ <xs:documentation>MEV dc, specific fan power of fans in room, rooms
793
+ other than kitchen, in watts per (litres per second); if mechanical
794
+ vent data from manufacturer declaration (MEV dc).
795
+ </xs:documentation>
796
+ </xs:annotation>
797
+ </xs:element>
798
+ <xs:element name="Kitchen-Duct-Fans-Count" type="Count" minOccurs="0">
799
+ <xs:annotation>
800
+ <xs:documentation>MEV dc, number of fans via duct, kitchen; if
801
+ mechanical vent data from database or manufacturer declaration (MEV
802
+ dc).
803
+ </xs:documentation>
804
+ </xs:annotation>
805
+ </xs:element>
806
+ <xs:element name="Kitchen-Duct-Fans-Specific-Power" type="Measurement"
807
+ minOccurs="0">
808
+ <xs:annotation>
809
+ <xs:documentation>MEV dc, specific fan power of fans via duct,
810
+ kitchen, in watts per (litres per second); if mechanical vent data
811
+ from manufacturer declaration (MEV dc).
812
+ </xs:documentation>
813
+ </xs:annotation>
814
+ </xs:element>
815
+ <xs:element name="Non-Kitchen-Duct-Fans-Count" type="Count" minOccurs="0">
816
+ <xs:annotation>
817
+ <xs:documentation>MEV dc, number of fans via duct, rooms other than
818
+ kitchen; if mechanical vent data from database or manufacturer
819
+ declaration (MEV dc).
820
+ </xs:documentation>
821
+ </xs:annotation>
822
+ </xs:element>
823
+ <xs:element name="Non-Kitchen-Duct-Fans-Specific-Power" type="Measurement"
824
+ minOccurs="0">
825
+ <xs:annotation>
826
+ <xs:documentation>MEV dc, specific fan power of fans via duct, rooms
827
+ other than kitchen, in watts per (litres per second); if mechanical
828
+ vent data from manufacturer declaration (MEV dc).
829
+ </xs:documentation>
830
+ </xs:annotation>
831
+ </xs:element>
832
+ <xs:element name="Kitchen-Wall-Fans-Count" type="Count" minOccurs="0">
833
+ <xs:annotation>
834
+ <xs:documentation>MEV dc, number of fans through wall, kitchen; if
835
+ mechanical vent data from database or manufacturer declaration (MEV
836
+ dc).
837
+ </xs:documentation>
838
+ </xs:annotation>
839
+ </xs:element>
840
+ <xs:element name="Kitchen-Wall-Fans-Specific-Power" type="Measurement"
841
+ minOccurs="0">
842
+ <xs:annotation>
843
+ <xs:documentation>MEV dc, specific fan power of fans through wall,
844
+ kitchen, in watts per (litres per second); if mechanical vent data
845
+ from manufacturer declaration (MEV dc).
846
+ </xs:documentation>
847
+ </xs:annotation>
848
+ </xs:element>
849
+ <xs:element name="Non-Kitchen-Wall-Fans-Count" type="Count" minOccurs="0">
850
+ <xs:annotation>
851
+ <xs:documentation>MEV dc, number of fans through wall, rooms other
852
+ than kitchen; if mechanical vent data from database or manufacturer
853
+ declaration (MEV dc).
854
+ </xs:documentation>
855
+ </xs:annotation>
856
+ </xs:element>
857
+ <xs:element name="Non-Kitchen-Wall-Fans-Specific-Power" type="Measurement"
858
+ minOccurs="0">
859
+ <xs:annotation>
860
+ <xs:documentation>MEV dc, specific fan power of fans through wall,
861
+ rooms other than kitchen, in watts per (litres per second); if
862
+ mechanical vent data from manufacturer declaration (MEV dc).
863
+ </xs:documentation>
864
+ </xs:annotation>
865
+ </xs:element>
866
+ <xs:element name="Extract-Fans-Count" type="Count" minOccurs="0"/>
867
+ <xs:element name="PSV-Count" type="Count" minOccurs="0"/>
868
+ <xs:element name="Is-Mechanical-Vent-Approved-Installer-Scheme"
869
+ type="xs:boolean" minOccurs="0"/>
870
+ <xs:element name="Mechanical-Vent-Ducts-Index-Number"
871
+ type="xs:positiveInteger" minOccurs="0">
872
+ <xs:annotation>
873
+ <xs:documentation>Mechanical vent ducts index number; if applicable.
874
+ </xs:documentation>
875
+ </xs:annotation>
876
+ </xs:element>
877
+ </xs:all>
878
+ </xs:complexType>
879
+ <xs:element name="SAP10-Data" type="SAP10-Data"/>
880
+ <xs:complexType name="SAP10-Data">
881
+ <xs:annotation>
882
+ <xs:documentation>These are the specific data-items collected by the HI /
883
+ EA needed to perform the SAP calculation.
884
+ </xs:documentation>
885
+ </xs:annotation>
886
+ <xs:all>
887
+ <xs:element name="Data-Type" type="SAP-DataTypeCode">
888
+ <xs:annotation>
889
+ <xs:documentation>Type of SAP data that has been collected.
890
+ </xs:documentation>
891
+ </xs:annotation>
892
+ </xs:element>
893
+ <xs:element name="SAP-Property-Details" type="SAP-Property-Details"/>
894
+ </xs:all>
895
+ </xs:complexType>
896
+ <xs:element name="SAP-Property-Details" type="SAP-Property-Details"/>
897
+ <xs:complexType name="SAP-Property-Details">
898
+ <xs:annotation>
899
+ <xs:documentation>Various measurements a particular Property.
900
+ </xs:documentation>
901
+ </xs:annotation>
902
+ <xs:all>
903
+ <xs:element name="Property-Type" type="PropertyTypeCode">
904
+ <xs:annotation>
905
+ <xs:documentation>The type of Property, such as House, Flat, Mansion,
906
+ Maisonette etc.
907
+ </xs:documentation>
908
+ </xs:annotation>
909
+ </xs:element>
910
+ <xs:element name="Built-Form" type="SAP-BuiltFormCode" minOccurs="0">
911
+ <xs:annotation>
912
+ <xs:documentation>The building type of the Property e.g. Detached,
913
+ Semi-Detached, Terrace etc.
914
+
915
+ Together with the Property Type, the Built Form provides a
916
+ structured description of the property.
917
+ </xs:documentation>
918
+ </xs:annotation>
919
+ </xs:element>
920
+ <xs:element name="Living-Area" type="Measurement">
921
+ <xs:annotation>
922
+ <xs:documentation>The size of the living area in square metres. The
923
+ living area is the room marked on a plan as the lounge or living
924
+ room, or the largest public room (irrespective of usage by
925
+ particular occupants), together with any rooms not separated from
926
+ the lounge or living room by doors, and including any cupboards
927
+ directly accessed from the lounge or living room. Living area does
928
+ not, however, extend over more than one storey, even when stairs
929
+ enter the living area directly.
930
+ </xs:documentation>
931
+ </xs:annotation>
932
+ </xs:element>
933
+ <xs:element name="Lowest-Storey-Area" type="xs:decimal">
934
+ <xs:annotation>
935
+ <xs:documentation>The Area of the lowest storey in square meters
936
+ including unheated or communal areas such as garages or corridors.
937
+ </xs:documentation>
938
+ </xs:annotation>
939
+ </xs:element>
940
+ <xs:element name="Orientation" type="SAP-OrientationCode">
941
+ <xs:annotation>
942
+ <xs:documentation>The orientation of the front of the property.
943
+ </xs:documentation>
944
+ </xs:annotation>
945
+ </xs:element>
946
+ <xs:element name="Conservatory-Type" type="SAP-ConservatoryTypeCode">
947
+ <xs:annotation>
948
+ <xs:documentation>Type of conservatory.</xs:documentation>
949
+ </xs:annotation>
950
+ </xs:element>
951
+ <xs:element name="Terrain-Type" type="SAP-TerrainTypeCode">
952
+ <xs:annotation>
953
+ <xs:documentation>Terrain type. Needed for wind-turbines and for
954
+ applying measures.
955
+ </xs:documentation>
956
+ </xs:annotation>
957
+ </xs:element>
958
+ <xs:element name="Has-Special-Feature" type="xs:boolean" default="false"
959
+ minOccurs="0">
960
+ <xs:annotation>
961
+ <xs:documentation>For backwards compatibility only, do not use.
962
+ </xs:documentation>
963
+ </xs:annotation>
964
+ </xs:element>
965
+ <xs:element name="Special-Feature-Description" type="Sentence"
966
+ minOccurs="0">
967
+ <xs:annotation>
968
+ <xs:documentation>For backwards compatibility only, do not use.
969
+ </xs:documentation>
970
+ </xs:annotation>
971
+ </xs:element>
972
+ <xs:element name="Energy-Saved-Or-Generated" type="Measurement"
973
+ minOccurs="0">
974
+ <xs:annotation>
975
+ <xs:documentation>For backwards compatibility only, do not use.
976
+ </xs:documentation>
977
+ </xs:annotation>
978
+ </xs:element>
979
+ <xs:element name="Saved-Or-Generated-Fuel" type="HeatingFuelTypeCode"
980
+ minOccurs="0">
981
+ <xs:annotation>
982
+ <xs:documentation>For backwards compatibility only, do not use.
983
+ </xs:documentation>
984
+ </xs:annotation>
985
+ </xs:element>
986
+ <xs:element name="Energy-Used" type="Measurement" minOccurs="0">
987
+ <xs:annotation>
988
+ <xs:documentation>For backwards compatibility only, do not use.
989
+ </xs:documentation>
990
+ </xs:annotation>
991
+ </xs:element>
992
+ <xs:element name="Energy-Used-Fuel" type="HeatingFuelTypeCode"
993
+ minOccurs="0">
994
+ <xs:annotation>
995
+ <xs:documentation>For backwards compatibility only, do not use.
996
+ </xs:documentation>
997
+ </xs:annotation>
998
+ </xs:element>
999
+ <xs:element name="Is-In-Smoke-Control-Area" type="ExtendedBoolean">
1000
+ <xs:annotation>
1001
+ <xs:documentation>Is property in a smoke control area? Only if a solid
1002
+ fuel appliance is used.
1003
+ </xs:documentation>
1004
+ </xs:annotation>
1005
+ </xs:element>
1006
+ <xs:element name="Part-O-Cooling-Required" type="xs:boolean" minOccurs="0">
1007
+ <xs:annotation>
1008
+ <xs:documentation>Has a Part O analysis indicating that active cooling is required in the dwelling? Default is 'no'.
1009
+ </xs:documentation>
1010
+ </xs:annotation>
1011
+ </xs:element>
1012
+ <xs:element name="Cold-Water-Source" type="ColdWaterSourceCode">
1013
+ <xs:annotation>
1014
+ <xs:documentation>What is the cold water source? Either mains or
1015
+ header tank.
1016
+ </xs:documentation>
1017
+ </xs:annotation>
1018
+ </xs:element>
1019
+ <xs:element name="Windows-Overshading" type="SAP-WindowOvershadingCode">
1020
+ <xs:annotation>
1021
+ <xs:documentation>Average amount of overshading of windows.
1022
+ </xs:documentation>
1023
+ </xs:annotation>
1024
+ </xs:element>
1025
+ <xs:element name="Thermal-Mass-Parameter" type="xs:decimal" minOccurs="0">
1026
+ <xs:annotation>
1027
+ <xs:documentation>Average thermal mass parameter for the dwelling in
1028
+ kJ/m²K. If omitted it is calculated using the kappa values of each
1029
+ element.
1030
+ </xs:documentation>
1031
+ </xs:annotation>
1032
+ </xs:element>
1033
+ <xs:element name="Additional-Allowable-Electricity-Generation"
1034
+ type="Measurement" minOccurs="0">
1035
+ <xs:annotation>
1036
+ <xs:documentation>Additional allowable electricity generation
1037
+ applicable to this dwelling in kWh per square metre; only if Zero
1038
+ Carbon Home assessment.
1039
+ </xs:documentation>
1040
+ </xs:annotation>
1041
+ </xs:element>
1042
+ <xs:element name="Gas-Smart-Meter-Present" type="xs:boolean"
1043
+ default="false"/>
1044
+ <xs:element name="Electricity-Smart-Meter-Present" type="xs:boolean"
1045
+ default="false"/>
1046
+ <xs:element name="Is-Dwelling-Export-Capable" type="xs:boolean"/>
1047
+ <xs:element name="PV-Connection" type="PVConnectionCode" minOccurs="0"/>
1048
+ <xs:element name="PV-Diverter" type="xs:boolean" default="false"
1049
+ minOccurs="0">
1050
+ <xs:annotation>
1051
+ <xs:documentation>Diverter present.</xs:documentation>
1052
+ </xs:annotation>
1053
+ </xs:element>
1054
+ <xs:element name="Battery-Capacity" type="xs:decimal" minOccurs="0">
1055
+ <xs:annotation>
1056
+ <xs:documentation>Battery capacity if diverter present.
1057
+ </xs:documentation>
1058
+ </xs:annotation>
1059
+ </xs:element>
1060
+ <xs:element name="Is-Wind-Turbine-Connected-To-Dwelling-Meter"
1061
+ type="xs:boolean" default="true" minOccurs="0">
1062
+ <xs:annotation>
1063
+ <xs:documentation>Whether the wind turbine is connected to the
1064
+ Dwelling's meter.
1065
+ </xs:documentation>
1066
+ </xs:annotation>
1067
+ </xs:element>
1068
+ <xs:element name="SAP-Heating" type="SAP-Heating"/>
1069
+ <xs:element name="SAP-Energy-Source" type="SAP-Energy-Source"
1070
+ minOccurs="0"/>
1071
+ <xs:element name="SAP-Building-Parts" type="SAP-Building-Parts"/>
1072
+ <xs:element name="SAP-Opening-Types" type="SAP-Opening-Types"
1073
+ minOccurs="0"/>
1074
+ <xs:element name="SAP-Ventilation" type="SAP-Ventilation" minOccurs="0"/>
1075
+ <xs:element name="SAP-Lighting" type="SAP-Lighting" minOccurs="0"/>
1076
+ <xs:element name="SAP-Deselected-Improvements"
1077
+ type="SAP-Deselected-Improvements" minOccurs="0"/>
1078
+ <xs:element name="SAP-Flat-Details" type="SAP-Flat-Details"
1079
+ minOccurs="0"/>
1080
+ <xs:element name="SAP-Special-Features" type="SAP-Special-Features"
1081
+ minOccurs="0"/>
1082
+ <xs:element name="Design-Water-Use" type="DesignWaterUseCode"
1083
+ minOccurs="0">
1084
+ <xs:annotation>
1085
+ <xs:documentation>Design limit for total water use.</xs:documentation>
1086
+ </xs:annotation>
1087
+ </xs:element>
1088
+ <xs:element name="SAP-Cooling" type="SAP-Cooling" minOccurs="0"/>
1089
+ </xs:all>
1090
+ </xs:complexType>
1091
+ <xs:element name="SAP-Flat-Details" type="SAP-Flat-Details"/>
1092
+ <xs:complexType name="SAP-Flat-Details">
1093
+ <xs:all>
1094
+ <xs:element name="Level" type="SAP-FlatLevelCode">
1095
+ <xs:annotation>
1096
+ <xs:documentation>Indication of where a flat is located in a
1097
+ building.
1098
+ </xs:documentation>
1099
+ </xs:annotation>
1100
+ </xs:element>
1101
+ <xs:element name="Storeys" type="NonZeroCount">
1102
+ <xs:annotation>
1103
+ <xs:documentation>Count of number of storeys present in the block of
1104
+ flats.
1105
+ </xs:documentation>
1106
+ </xs:annotation>
1107
+ </xs:element>
1108
+ </xs:all>
1109
+ </xs:complexType>
1110
+ <xs:element name="SAP-Lighting" type="SAP-Lighting"/>
1111
+ <xs:complexType name="SAP-Lighting">
1112
+ <xs:annotation>
1113
+ <xs:documentation>Details of the main lighting for the property
1114
+ </xs:documentation>
1115
+ </xs:annotation>
1116
+ <xs:sequence>
1117
+ <xs:element name="Fixed-Lights" type="Fixed-Lights" minOccurs="0">
1118
+ <xs:annotation>
1119
+ <xs:documentation>The record of a lighting type within the building.
1120
+ </xs:documentation>
1121
+ </xs:annotation>
1122
+ </xs:element>
1123
+ </xs:sequence>
1124
+ </xs:complexType>
1125
+ <xs:element name="Fixed-Lights" type="Fixed-Lights"/>
1126
+ <xs:complexType name="Fixed-Lights">
1127
+ <xs:annotation>
1128
+ <xs:documentation>Fixed lighting present in the property.
1129
+ </xs:documentation>
1130
+ </xs:annotation>
1131
+ <xs:sequence>
1132
+ <xs:element name="Fixed-Light" type="Fixed-Light" maxOccurs="unbounded"/>
1133
+ </xs:sequence>
1134
+ </xs:complexType>
1135
+ <xs:element name="Fixed-Light" type="Fixed-Light"/>
1136
+ <xs:complexType name="Fixed-Light">
1137
+ <xs:annotation>
1138
+ <xs:documentation>Various details for each fixed lighting type in the
1139
+ property.
1140
+ </xs:documentation>
1141
+ </xs:annotation>
1142
+ <xs:all>
1143
+ <xs:element name="Lighting-Efficacy" type="xs:decimal">
1144
+ <xs:annotation>
1145
+ <xs:documentation>The efficacy of the lighting type in lumens/Watt.
1146
+ </xs:documentation>
1147
+ </xs:annotation>
1148
+ </xs:element>
1149
+ <xs:element name="Lighting-Power" type="xs:decimal">
1150
+ <xs:annotation>
1151
+ <xs:documentation>The power of the selected lighting type in Watts.
1152
+ </xs:documentation>
1153
+ </xs:annotation>
1154
+ </xs:element>
1155
+ <xs:element name="Lighting-Outlets" type="Count">
1156
+ <xs:annotation>
1157
+ <xs:documentation>The number of light fitting outlets of that type.
1158
+ </xs:documentation>
1159
+ </xs:annotation>
1160
+ </xs:element>
1161
+ </xs:all>
1162
+ </xs:complexType>
1163
+ <xs:element name="SAP-Floor-Dimension" type="SAP-Floor-Dimension"/>
1164
+ <xs:complexType name="SAP-Floor-Dimension">
1165
+ <xs:annotation>
1166
+ <xs:documentation>Various measurements for the floor of a particular
1167
+ storey.
1168
+ </xs:documentation>
1169
+ </xs:annotation>
1170
+ <xs:all>
1171
+ <xs:element name="Name" type="xs:string" minOccurs="0">
1172
+ <xs:annotation>
1173
+ <xs:documentation>A name describing the floor dimensioned.
1174
+ </xs:documentation>
1175
+ </xs:annotation>
1176
+ </xs:element>
1177
+ <xs:element name="Storey" type="SAP-StoreyFloorCode">
1178
+ <xs:annotation>
1179
+ <xs:documentation>Building storey on which the floor is located.
1180
+ </xs:documentation>
1181
+ </xs:annotation>
1182
+ </xs:element>
1183
+ <xs:element name="Description" type="Sentence" minOccurs="0">
1184
+ <xs:annotation>
1185
+ <xs:documentation>Descriptive notes about the floor.
1186
+ </xs:documentation>
1187
+ </xs:annotation>
1188
+ </xs:element>
1189
+ <xs:element name="Floor-Type" type="SAP-FloorTypeCode">
1190
+ <xs:annotation>
1191
+ <xs:documentation>Type of floor (exposure).</xs:documentation>
1192
+ </xs:annotation>
1193
+ </xs:element>
1194
+ <xs:element name="Total-Floor-Area" type="Measurement">
1195
+ <xs:annotation>
1196
+ <xs:documentation>The total floor area of the storey in square
1197
+ metres.
1198
+ </xs:documentation>
1199
+ </xs:annotation>
1200
+ </xs:element>
1201
+ <xs:element name="Storey-Height" type="Measurement">
1202
+ <xs:annotation>
1203
+ <xs:documentation>Average height of the storey in metres.
1204
+ </xs:documentation>
1205
+ </xs:annotation>
1206
+ </xs:element>
1207
+ <xs:element name="Heat-Loss-Area" type="Measurement">
1208
+ <xs:annotation>
1209
+ <xs:documentation>The estimated total heat loss area for the floor in
1210
+ square metres.
1211
+ </xs:documentation>
1212
+ </xs:annotation>
1213
+ </xs:element>
1214
+ <xs:element name="U-Value" type="xs:decimal">
1215
+ <xs:annotation>
1216
+ <xs:documentation>Heat loss floor U-value.</xs:documentation>
1217
+ </xs:annotation>
1218
+ </xs:element>
1219
+ <xs:element name="Kappa-Value" type="xs:decimal" minOccurs="0">
1220
+ <xs:annotation>
1221
+ <xs:documentation>Heat capacity of floor per unit area in kJ/m²K.
1222
+ </xs:documentation>
1223
+ </xs:annotation>
1224
+ </xs:element>
1225
+ <xs:element name="Kappa-Value-From-Below" type="xs:decimal" minOccurs="0">
1226
+ <xs:annotation>
1227
+ <xs:documentation>Heat capacity of ceiling below. Applies to the
1228
+ non-heat-loss area of an upper floor.
1229
+ </xs:documentation>
1230
+ </xs:annotation>
1231
+ </xs:element>
1232
+ </xs:all>
1233
+ </xs:complexType>
1234
+ <xs:element name="SAP-Building-Parts" type="SAP-Building-Parts"/>
1235
+ <xs:complexType name="SAP-Building-Parts">
1236
+ <xs:annotation>
1237
+ <xs:documentation>Details of the significant building parts that comprise
1238
+ the main habitable building in the property. The main habitable area
1239
+ generally consists of a single main building but can over time be
1240
+ extended to include extensions such as new wings and additional storeys.
1241
+
1242
+ For the purpose of calculating the overall Energy Assessment for the
1243
+ property details of each distinct Building Part, such as its
1244
+ construction, have to be gathered because different materials have
1245
+ different insulation ratings (obviously) which affects the overall
1246
+ rating.
1247
+ </xs:documentation>
1248
+ </xs:annotation>
1249
+ <xs:sequence>
1250
+ <xs:element name="SAP-Building-Part" type="SAP-Building-Part"
1251
+ maxOccurs="unbounded"/>
1252
+ </xs:sequence>
1253
+ </xs:complexType>
1254
+ <xs:element name="SAP-Building-Part" type="SAP-Building-Part"/>
1255
+ <xs:complexType name="SAP-Building-Part">
1256
+ <xs:annotation>
1257
+ <xs:documentation>A permanent structure that forms part of the Property
1258
+ and is built primarily for human habitation. A Building Part is usually
1259
+ made up of one or more Storey's and may contain a number of Internal
1260
+ Structural Features. An extension is also a Building Part.
1261
+ </xs:documentation>
1262
+ </xs:annotation>
1263
+ <xs:all>
1264
+ <xs:element name="Building-Part-Number" type="xs:positiveInteger">
1265
+ <xs:annotation>
1266
+ <xs:documentation>An integer value which uniquely identifies the
1267
+ building part in the property. The value "1" must be assigned to the
1268
+ main dwelling.
1269
+ </xs:documentation>
1270
+ </xs:annotation>
1271
+ </xs:element>
1272
+ <xs:element name="Identifier" type="IDString" minOccurs="0">
1273
+ <xs:annotation>
1274
+ <xs:documentation>Identifier for the Building part - generally only
1275
+ required if there are more that one Building Parts of the same type
1276
+ e.g. "West Wing" and "East Wing" Extensions
1277
+ </xs:documentation>
1278
+ </xs:annotation>
1279
+ </xs:element>
1280
+ <xs:element name="Construction-Year" type="xs:nonNegativeInteger"
1281
+ minOccurs="0">
1282
+ <xs:annotation>
1283
+ <xs:documentation>The year when this building part was constructed.
1284
+ Not used if 'Construction-Age-Band' is used.
1285
+ </xs:documentation>
1286
+ </xs:annotation>
1287
+ </xs:element>
1288
+ <xs:element name="Construction-Age-Band" type="ConstructionDateCode"
1289
+ minOccurs="0">
1290
+ <xs:annotation>
1291
+ <xs:documentation>The age band when this building part was
1292
+ constructed. Not used if 'Construction-Year' is used.
1293
+ </xs:documentation>
1294
+ </xs:annotation>
1295
+ </xs:element>
1296
+ <xs:element name="SAP-Openings" type="SAP-Openings" minOccurs="0"/>
1297
+ <xs:element name="SAP-Roofs" type="SAP-Roofs" minOccurs="0"/>
1298
+ <xs:element name="SAP-Floor-Dimensions" type="SAP-Floor-Dimensions"
1299
+ minOccurs="0"/>
1300
+ <xs:element name="SAP-Thermal-Bridges" type="SAP-Thermal-Bridges"
1301
+ minOccurs="0"/>
1302
+ <xs:element name="SAP-Walls" type="SAP-Walls" minOccurs="0"/>
1303
+ </xs:all>
1304
+ </xs:complexType>
1305
+ <xs:element name="SAP-Energy-Source" type="SAP-Energy-Source"/>
1306
+ <xs:complexType name="SAP-Energy-Source">
1307
+ <xs:annotation>
1308
+ <xs:documentation>Details of the main Electricity supply to the
1309
+ Property.
1310
+ </xs:documentation>
1311
+ </xs:annotation>
1312
+ <xs:all>
1313
+ <xs:element name="PV-Arrays" type="PV-Arrays" minOccurs="0"/>
1314
+ <xs:element name="Wind-Turbines" type="Wind-Turbines" minOccurs="0"/>
1315
+ <xs:element name="Electricity-Tariff" type="SAP-ElectricityTariffCode">
1316
+ <xs:annotation>
1317
+ <xs:documentation>Type of electricity tariff.</xs:documentation>
1318
+ </xs:annotation>
1319
+ </xs:element>
1320
+ <xs:element name="Hydro-Electric-Generation" type="xs:decimal"
1321
+ minOccurs="0">
1322
+ <xs:annotation>
1323
+ <xs:documentation>Electricity generated by hydro-electric generator,
1324
+ in kWh/year. To be provided if Hydro-Electric-Generation-Month is
1325
+ not provided.
1326
+ </xs:documentation>
1327
+ </xs:annotation>
1328
+ </xs:element>
1329
+ <xs:element name="Hydro-Electric-Certificate" type="xs:string"
1330
+ minOccurs="0">
1331
+ <xs:annotation>
1332
+ <xs:documentation>Reference to certification of hydro electric
1333
+ output.
1334
+ </xs:documentation>
1335
+ </xs:annotation>
1336
+ </xs:element>
1337
+ <xs:element name="Hydro-Electric-Generation-Months"
1338
+ type="Hydro-Electric-Generation-Months" minOccurs="0">
1339
+ <xs:annotation>
1340
+ <xs:documentation>Electricity generated by hydro-electric generator,
1341
+ in kWh/month. To be provided if Hydro-Electric-Generation is not
1342
+ provided.
1343
+ </xs:documentation>
1344
+ </xs:annotation>
1345
+ </xs:element>
1346
+ <xs:element name="Is-Hydro-Output-Connected-To-Dwelling-Meter"
1347
+ type="xs:boolean" default="true" minOccurs="0">
1348
+ <xs:annotation>
1349
+ <xs:documentation>Whether the hydro-electric station is connected to
1350
+ dwelling's electricity meter
1351
+ </xs:documentation>
1352
+ </xs:annotation>
1353
+ </xs:element>
1354
+ </xs:all>
1355
+ </xs:complexType>
1356
+ <xs:element name="SAP-Heating" type="SAP-Heating"/>
1357
+ <xs:complexType name="SAP-Heating">
1358
+ <xs:annotation>
1359
+ <xs:documentation>Details of the means by which the Main Building is
1360
+ heated.
1361
+ </xs:documentation>
1362
+ </xs:annotation>
1363
+ <xs:all>
1364
+ <xs:element name="Water-Heating-Code" type="SAP-WaterHeatingCode">
1365
+ <xs:annotation>
1366
+ <xs:documentation>The type of Water Heating present in the Property.
1367
+ </xs:documentation>
1368
+ </xs:annotation>
1369
+ </xs:element>
1370
+ <xs:element name="Water-Fuel-Type" type="HeatingFuelTypeCode"
1371
+ minOccurs="0">
1372
+ <xs:annotation>
1373
+ <xs:documentation>The type of fuel used to power the central heating
1374
+ e.g. Gas, Electricity. Not used if water system is main or secondary
1375
+ system.
1376
+ </xs:documentation>
1377
+ </xs:annotation>
1378
+ </xs:element>
1379
+ <xs:element name="Has-Hot-Water-Cylinder" type="xs:boolean"
1380
+ default="false" minOccurs="0">
1381
+ <xs:annotation>
1382
+ <xs:documentation>Hot water cylinder?</xs:documentation>
1383
+ </xs:annotation>
1384
+ </xs:element>
1385
+ <xs:element name="Secondary-Heating-Category"
1386
+ type="SAP-SecondaryHeatingCategoryCode">
1387
+ <xs:annotation>
1388
+ <xs:documentation>Category of heating system for the secondary heating
1389
+ system.
1390
+ </xs:documentation>
1391
+ </xs:annotation>
1392
+ </xs:element>
1393
+ <xs:element name="Secondary-Heating-Data-Source"
1394
+ type="SAP-NonDatabaseSourceCode" minOccurs="0">
1395
+ <xs:annotation>
1396
+ <xs:documentation>Source of secondary heating system data; only if
1397
+ secondary heating system.
1398
+ </xs:documentation>
1399
+ </xs:annotation>
1400
+ </xs:element>
1401
+ <xs:element name="Secondary-Heating-Efficiency" type="xs:decimal"
1402
+ minOccurs="0"/>
1403
+ <xs:element name="Secondary-Heating-Commisioning-Certificate"
1404
+ type="xs:string" minOccurs="0">
1405
+ <xs:annotation>
1406
+ <xs:documentation>Secondary heating system commisioning certificate
1407
+ number.
1408
+ </xs:documentation>
1409
+ </xs:annotation>
1410
+ </xs:element>
1411
+ <xs:element name="Secondary-Heating-Installation-Engineer"
1412
+ type="xs:string" minOccurs="0">
1413
+ <xs:annotation>
1414
+ <xs:documentation>Secondary heating installation engineer registration
1415
+ reference.
1416
+ </xs:documentation>
1417
+ </xs:annotation>
1418
+ </xs:element>
1419
+ <xs:element name="Secondary-Heating-Code" type="SAP-SpaceHeatingCode"
1420
+ minOccurs="0">
1421
+ <xs:annotation>
1422
+ <xs:documentation>Type of secondary heating present in the property;
1423
+ only if required and if heating data source is SAP table.
1424
+ </xs:documentation>
1425
+ </xs:annotation>
1426
+ </xs:element>
1427
+ <xs:element name="Secondary-Fuel-Type" type="HeatingFuelTypeCode"
1428
+ minOccurs="0">
1429
+ <xs:annotation>
1430
+ <xs:documentation>The type of fuel used to power the secondary heating
1431
+ e.g. Gas, Electricity; only if required.
1432
+ </xs:documentation>
1433
+ </xs:annotation>
1434
+ </xs:element>
1435
+ <xs:element name="Secondary-Heating-PCDF-Fuel-Index"
1436
+ type="xs:positiveInteger" minOccurs="0">
1437
+ <xs:annotation>
1438
+ <xs:documentation>PCDF index number of the fuel type, only if
1439
+ Secondary-Fuel-Type is 99 (fuel from database).
1440
+ </xs:documentation>
1441
+ </xs:annotation>
1442
+ </xs:element>
1443
+ <xs:element name="Secondary-Heating-Flue-Type" type="FlueTypeCode"
1444
+ minOccurs="0">
1445
+ <xs:annotation>
1446
+ <xs:documentation>Secondary flue type; only if secondary efficiency is
1447
+ manufacturer declaration and if there is a flue.
1448
+ </xs:documentation>
1449
+ </xs:annotation>
1450
+ </xs:element>
1451
+ <xs:element name="Thermal-Store" type="SAP-ThermalStoreCode"
1452
+ minOccurs="0">
1453
+ <xs:annotation>
1454
+ <xs:documentation>The type of thermal store; not used if main heating
1455
+ system is community heating scheme.
1456
+ </xs:documentation>
1457
+ </xs:annotation>
1458
+ </xs:element>
1459
+ <xs:element name="Has-Fixed-Air-Conditioning" type="xs:boolean"
1460
+ default="false" minOccurs="0">
1461
+ <xs:annotation>
1462
+ <xs:documentation>Fixed air conditioning?</xs:documentation>
1463
+ </xs:annotation>
1464
+ </xs:element>
1465
+ <xs:element name="Immersion-Heating-Type" type="ImmersionHeatingTypeCode"
1466
+ minOccurs="0">
1467
+ <xs:annotation>
1468
+ <xs:documentation>The type of immersion heating; only if immersion.
1469
+ </xs:documentation>
1470
+ </xs:annotation>
1471
+ </xs:element>
1472
+ <xs:element name="Is-Heat-Pump-Assisted-By-Immersion" type="xs:boolean"
1473
+ default="false" minOccurs="0">
1474
+ <xs:annotation>
1475
+ <xs:documentation>Is heat pump assisted by immersion? Applicable only
1476
+ to hot water only heat pumps
1477
+ </xs:documentation>
1478
+ </xs:annotation>
1479
+ </xs:element>
1480
+ <xs:element name="Is-Heat-Pump-Installed-To-MIS" type="xs:boolean"
1481
+ default="false" minOccurs="0">
1482
+ <xs:annotation>
1483
+ <xs:documentation>Is heat pump installed to MIS standard? Only if
1484
+ water heating from hot water only heat pump.
1485
+ </xs:documentation>
1486
+ </xs:annotation>
1487
+ </xs:element>
1488
+ <xs:element name="Is-Immersion-For-Summer-Use" type="xs:boolean"
1489
+ default="false" minOccurs="0">
1490
+ <xs:annotation>
1491
+ <xs:documentation>Immersion for summer use? Only if main heating is
1492
+ solid fuel fire or room heater with boiler.
1493
+ </xs:documentation>
1494
+ </xs:annotation>
1495
+ </xs:element>
1496
+ <xs:element name="Is-Secondary-Heating-HETAS-Approved" type="xs:boolean"
1497
+ default="false" minOccurs="0">
1498
+ <xs:annotation>
1499
+ <xs:documentation>Secondary heating appliance is HETAS approved? Only
1500
+ if solid fuel.
1501
+ </xs:documentation>
1502
+ </xs:annotation>
1503
+ </xs:element>
1504
+ <xs:element name="Hot-Water-Store-Manufacturer" type="xs:string"
1505
+ default="false" minOccurs="0">
1506
+ <xs:annotation>
1507
+ <xs:documentation>Store Manufacturer name.</xs:documentation>
1508
+ </xs:annotation>
1509
+ </xs:element>
1510
+ <xs:element name="Hot-Water-Store-Model" type="xs:string" default="false"
1511
+ minOccurs="0">
1512
+ <xs:annotation>
1513
+ <xs:documentation>Store Model name.</xs:documentation>
1514
+ </xs:annotation>
1515
+ </xs:element>
1516
+ <xs:element name="Hot-Water-Store-Commissioning-Certificate"
1517
+ type="xs:string" default="false" minOccurs="0">
1518
+ <xs:annotation>
1519
+ <xs:documentation>Store comissioning certificate number.
1520
+ </xs:documentation>
1521
+ </xs:annotation>
1522
+ </xs:element>
1523
+ <xs:element name="Hot-Water-Store-Installer-Engineer-Registration"
1524
+ type="xs:string" default="false" minOccurs="0">
1525
+ <xs:annotation>
1526
+ <xs:documentation>Store installer engineer registration number.
1527
+ </xs:documentation>
1528
+ </xs:annotation>
1529
+ </xs:element>
1530
+ <xs:element name="Hot-Water-Store-Size" type="Measurement" minOccurs="0">
1531
+ <xs:annotation>
1532
+ <xs:documentation>Hot water store size in litres; if there is a hot
1533
+ water store. Store refers to hot water store type which can be
1534
+ cylinder (if thermal store is "none"), hot-water only thermal store
1535
+ or integrated thermal store. Not applicable if (a) combi boiler
1536
+ whose data source database or (b) instantaneous combi boiler or (c)
1537
+ combi boiler from SAP table or (d) instantaneous water heater.
1538
+ </xs:documentation>
1539
+ </xs:annotation>
1540
+ </xs:element>
1541
+ <xs:element name="Hot-Water-Store-Heat-Transfer-Area" type="xs:decimal"
1542
+ minOccurs="0">
1543
+ <xs:annotation>
1544
+ <xs:documentation>Used when a heat pump is associated with a separate
1545
+ and specified hot water vessel.
1546
+ </xs:documentation>
1547
+ </xs:annotation>
1548
+ </xs:element>
1549
+ <xs:element name="Hot-Water-Store-Heat-Loss-Source"
1550
+ type="SAP-NonDatabaseSourceCode" minOccurs="0">
1551
+ <xs:annotation>
1552
+ <xs:documentation>The source of the hot water store heat loss
1553
+ information; if there is a hot water store. Not applicable if (a)
1554
+ combi boiler whose data source database or (b) instantaneous combi
1555
+ boiler or (c) combi boiler from SAP table or (d) instantaneous water
1556
+ heater.
1557
+ </xs:documentation>
1558
+ </xs:annotation>
1559
+ </xs:element>
1560
+ <xs:element name="Hot-Water-Store-Heat-Loss" type="Measurement"
1561
+ minOccurs="0">
1562
+ <xs:annotation>
1563
+ <xs:documentation>Hot water store declared loss in kWh/day; only if
1564
+ there is a hot water store and if manufacturer declared loss. Not
1565
+ applicable if (a) combi boiler whose data source database or (b)
1566
+ instantaneous combi boiler or (c) combi boiler from SAP table or (d)
1567
+ instantaneous water heater.
1568
+ </xs:documentation>
1569
+ </xs:annotation>
1570
+ </xs:element>
1571
+ <xs:element name="Hot-Water-Store-Insulation-Type"
1572
+ type="HotWaterStoreInsulationTypeCode" minOccurs="0">
1573
+ <xs:annotation>
1574
+ <xs:documentation>Hot water store insulation; only if there is a hot
1575
+ water store and if loss from SAP table. Not applicable if (a) combi
1576
+ boiler whose data source database or (b) instantaneous combi boiler
1577
+ or (c) combi boiler from SAP table or (d) instantaneous water
1578
+ heater.
1579
+ </xs:documentation>
1580
+ </xs:annotation>
1581
+ </xs:element>
1582
+ <xs:element name="Hot-Water-Store-Insulation-Thickness" type="Measurement"
1583
+ minOccurs="0">
1584
+ <xs:annotation>
1585
+ <xs:documentation>Hot water store insulation thickness in mm; only if
1586
+ there is a hot water store and if loss from SAP table. Not
1587
+ applicable if (a) combi boiler whose data source database or (b)
1588
+ instantaneous combi boiler or (c) combi boiler from SAP table or (d)
1589
+ instantaneous water heater.
1590
+ </xs:documentation>
1591
+ </xs:annotation>
1592
+ </xs:element>
1593
+ <xs:element name="Is-Thermal-Store-Near-Boiler" type="xs:boolean"
1594
+ default="false" minOccurs="0">
1595
+ <xs:annotation>
1596
+ <xs:documentation>Thermal store connected to boiler by no more than
1597
+ 1.5 m of insulated pipework? Only if thermal store. Not applicable
1598
+ if combi boiler or instantaneous water heater.
1599
+ </xs:documentation>
1600
+ </xs:annotation>
1601
+ </xs:element>
1602
+ <xs:element name="Is-Thermal-Store-Or-CPSU-In-Airing-Cupboard"
1603
+ type="xs:boolean" default="false" minOccurs="0">
1604
+ <xs:annotation>
1605
+ <xs:documentation>Thermal store or CPSU in airing cupboard? Only if
1606
+ (a) boiler with integrated or hot-water-only thermal store, or (b)
1607
+ main heating is CPSU.
1608
+ </xs:documentation>
1609
+ </xs:annotation>
1610
+ </xs:element>
1611
+ <xs:element name="Has-Cylinder-Thermostat" type="xs:boolean"
1612
+ default="false" minOccurs="0">
1613
+ <xs:annotation>
1614
+ <xs:documentation>Hot water cylinder thermostat? Not applicable if
1615
+ combi boiler or instantaneous water heater.
1616
+ </xs:documentation>
1617
+ </xs:annotation>
1618
+ </xs:element>
1619
+ <xs:element name="Is-Cylinder-In-Heated-Space" type="xs:boolean"
1620
+ default="false" minOccurs="0">
1621
+ <xs:annotation>
1622
+ <xs:documentation>Hot water cylinder in heated space? Not applicable
1623
+ if combi boiler or instantaneous water heater.
1624
+ </xs:documentation>
1625
+ </xs:annotation>
1626
+ </xs:element>
1627
+ <xs:element name="Is-Hot-Water-Separately-Timed" type="xs:boolean"
1628
+ default="false" minOccurs="0">
1629
+ <xs:annotation>
1630
+ <xs:documentation>Hot water separately timed? Not applicable if combi
1631
+ boiler or instantaneous water heater.
1632
+ </xs:documentation>
1633
+ </xs:annotation>
1634
+ </xs:element>
1635
+ <xs:element name="Hot-Water-Controls-Manufacturer" type="xs:string"
1636
+ minOccurs="0"/>
1637
+ <xs:element name="Hot-Water-Controls-Model" type="xs:string"
1638
+ minOccurs="0"/>
1639
+ <xs:element name="SAP-Community-Heating-Systems"
1640
+ type="SAP-Community-Heating-Systems" minOccurs="0"/>
1641
+ <xs:element name="Main-Heating-Details" type="Main-Heating-Details"/>
1642
+ <xs:element name="SAP-Heating-Design-Water-Use" type="DesignWaterUseCode"
1643
+ minOccurs="0"/>
1644
+ <xs:element name="Main-Heating-Systems-Interaction"
1645
+ type="MainHeatingSystemsInteraction" minOccurs="0"/>
1646
+ <xs:element name="Secondary-Heating-Declared-Values"
1647
+ type="Heating-Declared-Values" minOccurs="0">
1648
+ <xs:annotation>
1649
+ <xs:documentation>Use when manufacturer’s declared values.
1650
+ </xs:documentation>
1651
+ </xs:annotation>
1652
+ </xs:element>
1653
+ <xs:element name="Primary-Pipework-Insulation"
1654
+ type="PipeworkInsulationCode" minOccurs="0">
1655
+ <xs:annotation>
1656
+ <xs:documentation>Not applicable to combi boiler or instantaneous
1657
+ water heater.
1658
+ </xs:documentation>
1659
+ </xs:annotation>
1660
+ </xs:element>
1661
+ <xs:element name="Solar-Heating-Details" type="Solar-Heating-Details"
1662
+ minOccurs="0"/>
1663
+ <xs:element name="Instantaneous-WWHRS" type="Instantaneous-WWHRS"
1664
+ minOccurs="0">
1665
+ <xs:annotation>
1666
+ <xs:documentation>Waste Water Heat Recovery System.</xs:documentation>
1667
+ </xs:annotation>
1668
+ </xs:element>
1669
+ <xs:element name="Storage-WWHRS" type="Storage-WWHRS" minOccurs="0"/>
1670
+ <xs:element name="Shower-Outlets" type="Shower-Outlets" minOccurs="0"/>
1671
+ <xs:element name="Number-Baths" type="Count" minOccurs="0"/>
1672
+ <xs:element name="Number-Baths-WWHRS" type="Count" minOccurs="0"/>
1673
+ </xs:all>
1674
+ </xs:complexType>
1675
+ <xs:element name="SAP-Special-Feature" type="SAP-Special-Feature"/>
1676
+ <xs:complexType name="SAP-Special-Feature">
1677
+ <xs:sequence>
1678
+ <xs:element name="Description" type="xs:string"/>
1679
+ <xs:choice>
1680
+ <xs:element name="Energy-Feature" type="Energy-Feature"/>
1681
+ <xs:element name="Emissions-Feature" type="Emission-Feature"/>
1682
+ </xs:choice>
1683
+ </xs:sequence>
1684
+ </xs:complexType>
1685
+ <xs:element name="SAP-Special-Features" type="SAP-Special-Features"/>
1686
+ <xs:complexType name="SAP-Special-Features">
1687
+ <xs:sequence>
1688
+ <xs:element name="SAP-Special-Feature" type="SAP-Special-Feature"
1689
+ maxOccurs="unbounded"/>
1690
+ </xs:sequence>
1691
+ </xs:complexType>
1692
+ <xs:element name="SAP-Cooling" type="SAP-Cooling"/>
1693
+ <xs:complexType name="SAP-Cooling">
1694
+ <xs:all>
1695
+ <xs:element name="Cooled-Area" type="xs:decimal" minOccurs="0"/>
1696
+ <xs:element name="Cooling-System-Data-Source" type="SAP-DataSourceCode"
1697
+ minOccurs="0"/>
1698
+ <xs:element name="Cooling-System-Class" type="SAP-CoolingSystemClassCode"
1699
+ minOccurs="0">
1700
+ <xs:annotation>
1701
+ <xs:documentation>Data set includes either class or SEER, not both.
1702
+ </xs:documentation>
1703
+ </xs:annotation>
1704
+ </xs:element>
1705
+ <xs:element name="System-Energy-Efficiency-Ratio" type="xs:decimal"
1706
+ minOccurs="0">
1707
+ <xs:annotation>
1708
+ <xs:documentation>SEER.</xs:documentation>
1709
+ </xs:annotation>
1710
+ </xs:element>
1711
+ </xs:all>
1712
+ </xs:complexType>
1713
+ <xs:element name="Main-Heating" type="Main-Heating"/>
1714
+ <xs:complexType name="Main-Heating">
1715
+ <xs:all>
1716
+ <xs:element name="Main-Heating-Number">
1717
+ <xs:annotation>
1718
+ <xs:documentation>Identifies the main heating as system 1 or system 2.
1719
+ System 1 must always be present, system 2 is included only when
1720
+ there are two systems.
1721
+ </xs:documentation>
1722
+ </xs:annotation>
1723
+ <xs:simpleType>
1724
+ <xs:restriction base="xs:integer">
1725
+ <xs:minInclusive value="1"/>
1726
+ <xs:maxInclusive value="2"/>
1727
+ </xs:restriction>
1728
+ </xs:simpleType>
1729
+ </xs:element>
1730
+ <xs:element name="Main-Heating-Category"
1731
+ type="SAP-MainHeatingCategoryCode">
1732
+ <xs:annotation>
1733
+ <xs:documentation>Category of heating system for the main heating
1734
+ system.
1735
+ </xs:documentation>
1736
+ </xs:annotation>
1737
+ </xs:element>
1738
+ <xs:element name="Main-Heating-Data-Source" type="SAP-DataSourceCode">
1739
+ <xs:annotation>
1740
+ <xs:documentation>Source of main heating system data.
1741
+ </xs:documentation>
1742
+ </xs:annotation>
1743
+ </xs:element>
1744
+ <xs:element name="Main-Heating-Index-Number" type="xs:positiveInteger"
1745
+ minOccurs="0">
1746
+ <xs:annotation>
1747
+ <xs:documentation>The ID of the heating system from the product
1748
+ database, if system from database.
1749
+ </xs:documentation>
1750
+ </xs:annotation>
1751
+ </xs:element>
1752
+ <xs:element name="Main-Heating-Manufacturer" type="xs:string"
1753
+ minOccurs="0"/>
1754
+ <xs:element name="Main-Heating-Model" type="xs:string" minOccurs="0"/>
1755
+ <xs:element name="Main-Heating-Commissioning-Certificate" type="xs:string"
1756
+ minOccurs="0"/>
1757
+ <xs:element name="Main-Heating-Installation-Engineer" type="xs:string"
1758
+ minOccurs="0">
1759
+ <xs:annotation>
1760
+ <xs:documentation>Main heating installation engineer registration
1761
+ reference.
1762
+ </xs:documentation>
1763
+ </xs:annotation>
1764
+ </xs:element>
1765
+ <xs:element name="Is-Condensing-Boiler" type="xs:boolean" default="false"
1766
+ minOccurs="0">
1767
+ <xs:annotation>
1768
+ <xs:documentation>Is the boiler a condensing boiler? If boiler
1769
+ efficiency is manufacturer declaration.
1770
+ </xs:documentation>
1771
+ </xs:annotation>
1772
+ </xs:element>
1773
+ <xs:element name="Condensing-Boiler-Heat-Distribution"
1774
+ type="xs:positiveInteger" default="80" minOccurs="0">
1775
+ <xs:annotation>
1776
+ <xs:documentation>The temperature distribution of the condensing
1777
+ boiler.
1778
+ </xs:documentation>
1779
+ </xs:annotation>
1780
+ </xs:element>
1781
+ <xs:element name="Heat-Pump-Heat-Distribution" type="xs:positiveInteger"
1782
+ default="80" minOccurs="0">
1783
+ <xs:annotation>
1784
+ <xs:documentation>The temperature distribution of the heat pump, for
1785
+ wet systems only.
1786
+ </xs:documentation>
1787
+ </xs:annotation>
1788
+ </xs:element>
1789
+ <xs:element name="Gas-Or-Oil-Boiler-Type"
1790
+ type="SAP-GasOrOilBoilerTypeCode" minOccurs="0">
1791
+ <xs:annotation>
1792
+ <xs:documentation>Boiler type; if boiler efficiency is manufacturer
1793
+ declaration and fuel is gas or oil.
1794
+ </xs:documentation>
1795
+ </xs:annotation>
1796
+ </xs:element>
1797
+ <xs:element name="Combi-Boiler-Type" type="SAP-CombiBoilerTypeCode"
1798
+ minOccurs="0">
1799
+ <xs:annotation>
1800
+ <xs:documentation>Combi boiler type; if it is a combi boiler and
1801
+ boiler efficiency is manufacturer declaration.
1802
+ </xs:documentation>
1803
+ </xs:annotation>
1804
+ </xs:element>
1805
+ <xs:element name="Case-Heat-Emission" type="Measurement" minOccurs="0">
1806
+ <xs:annotation>
1807
+ <xs:documentation>Case heat emission at full load in kW; if it is a
1808
+ range cooker boiler and boiler efficiency is manufacturer
1809
+ declaration.
1810
+ </xs:documentation>
1811
+ </xs:annotation>
1812
+ </xs:element>
1813
+ <xs:element name="Heat-Transfer-To-Water" type="Measurement"
1814
+ minOccurs="0">
1815
+ <xs:annotation>
1816
+ <xs:documentation>Heat transfer to water at full load in kW; if it is
1817
+ a range cooker boiler and boiler efficiency is manufacturer
1818
+ declaration.
1819
+ </xs:documentation>
1820
+ </xs:annotation>
1821
+ </xs:element>
1822
+ <xs:element name="Solid-Fuel-Boiler-Type" type="SAP-SolidFuelBoilerType"
1823
+ minOccurs="0">
1824
+ <xs:annotation>
1825
+ <xs:documentation>Boiler type; if boiler efficiency is manufacturer
1826
+ declaration and fuel is solid.
1827
+ </xs:documentation>
1828
+ </xs:annotation>
1829
+ </xs:element>
1830
+ <xs:element name="Main-Heating-Code" type="SAP-SpaceHeatingCode"
1831
+ minOccurs="0">
1832
+ <xs:annotation>
1833
+ <xs:documentation>Main heating code; when heating data source is SAP
1834
+ table.
1835
+ </xs:documentation>
1836
+ </xs:annotation>
1837
+ </xs:element>
1838
+ <xs:element name="Main-Fuel-Type" type="HeatingFuelTypeCode"
1839
+ minOccurs="0">
1840
+ <xs:annotation>
1841
+ <xs:documentation>The type of fuel used to power the central heating
1842
+ e.g. Gas, Electricity; not used if main heating system is community
1843
+ heating scheme.
1844
+ </xs:documentation>
1845
+ </xs:annotation>
1846
+ </xs:element>
1847
+ <xs:element name="PCDF-Fuel-Index" type="xs:positiveInteger"
1848
+ minOccurs="0">
1849
+ <xs:annotation>
1850
+ <xs:documentation>PCDF index number of the fuel type, only if
1851
+ Main-Fuel-Type is 99 (fuel from database).
1852
+ </xs:documentation>
1853
+ </xs:annotation>
1854
+ </xs:element>
1855
+ <xs:element name="Main-Heating-Control" type="SAP-HeatingControlCode">
1856
+ <xs:annotation>
1857
+ <xs:documentation>Type of Main Control for the Heating System.
1858
+ </xs:documentation>
1859
+ </xs:annotation>
1860
+ </xs:element>
1861
+ <xs:element name="Heat-Emitter-Type" type="HeatEmitterCode" minOccurs="0">
1862
+ <xs:annotation>
1863
+ <xs:documentation>Identifies the means by which the central heating
1864
+ system (if present) emits heat; only when wet system (radiators or
1865
+ underfloor).
1866
+ </xs:documentation>
1867
+ </xs:annotation>
1868
+ </xs:element>
1869
+ <xs:element name="Underfloor-Heat-Emitter-Type"
1870
+ type="UnderfloorHeatEmitterCode" minOccurs="0">
1871
+ <xs:annotation>
1872
+ <xs:documentation>Means by which an underfloor heating system (if
1873
+ present) emits heat; only when wet system (underfloor).
1874
+ </xs:documentation>
1875
+ </xs:annotation>
1876
+ </xs:element>
1877
+ <xs:element name="Main-Heating-Flue-Type" type="FlueTypeCode"
1878
+ minOccurs="0">
1879
+ <xs:annotation>
1880
+ <xs:documentation>The type of main heating flue; only if flued
1881
+ appliance.
1882
+ </xs:documentation>
1883
+ </xs:annotation>
1884
+ </xs:element>
1885
+ <xs:element name="Is-Flue-Fan-Present" type="xs:boolean" default="false"
1886
+ minOccurs="0">
1887
+ <xs:annotation>
1888
+ <xs:documentation>Indicates whether the heating system contains a fan
1889
+ flue; only if boiler.
1890
+ </xs:documentation>
1891
+ </xs:annotation>
1892
+ </xs:element>
1893
+ <xs:element name="Is-Central-Heating-Pump-In-Heated-Space"
1894
+ type="xs:boolean" default="false" minOccurs="0">
1895
+ <xs:annotation>
1896
+ <xs:documentation>Central heating pump in heated space? Only when wet
1897
+ system (radiators or underfloor).
1898
+ </xs:documentation>
1899
+ </xs:annotation>
1900
+ </xs:element>
1901
+ <xs:element name="Is-Oil-Pump-In-Heated-Space" type="xs:boolean"
1902
+ default="false" minOccurs="0">
1903
+ <xs:annotation>
1904
+ <xs:documentation>Oil pump in heated space? Only if oil boiler.
1905
+ </xs:documentation>
1906
+ </xs:annotation>
1907
+ </xs:element>
1908
+ <xs:element name="Is-Interlocked-System" type="xs:boolean" default="false"
1909
+ minOccurs="0">
1910
+ <xs:annotation>
1911
+ <xs:documentation>Interlocked system? Only when wet system (radiators
1912
+ or underfloor).
1913
+ </xs:documentation>
1914
+ </xs:annotation>
1915
+ </xs:element>
1916
+ <xs:element name="Has-Separate-Delayed-Start" type="xs:boolean"
1917
+ default="false" minOccurs="0">
1918
+ <xs:annotation>
1919
+ <xs:documentation>True if there is a delayed start control separate
1920
+ from a controller in the database.
1921
+ </xs:documentation>
1922
+ </xs:annotation>
1923
+ </xs:element>
1924
+ <xs:element name="Boiler-Fuel-Feed" type="SAP-BoilerFuelFeedCode"
1925
+ minOccurs="0">
1926
+ <xs:annotation>
1927
+ <xs:documentation>The type of boiler fuel feed; only if solid fuel
1928
+ boiler with manufacturer declaration.
1929
+ </xs:documentation>
1930
+ </xs:annotation>
1931
+ </xs:element>
1932
+ <xs:element name="Is-Main-Heating-HETAS-Approved" type="xs:boolean"
1933
+ default="false" minOccurs="0">
1934
+ <xs:annotation>
1935
+ <xs:documentation>Main heating appliance is HETAS approved? Only if
1936
+ solid fuel.
1937
+ </xs:documentation>
1938
+ </xs:annotation>
1939
+ </xs:element>
1940
+ <xs:element name="Electric-CPSU-Operating-Temperature" type="Measurement"
1941
+ minOccurs="0">
1942
+ <xs:annotation>
1943
+ <xs:documentation>Electric CPSU operating temperature in Celcius; only
1944
+ if main heating is electric CPSU.
1945
+ </xs:documentation>
1946
+ </xs:annotation>
1947
+ </xs:element>
1948
+ <xs:element name="Main-Heating-Fraction" type="xs:decimal">
1949
+ <xs:annotation>
1950
+ <xs:documentation>Fraction of main heating provided by this system, is
1951
+ 1 if only one main system.
1952
+ </xs:documentation>
1953
+ </xs:annotation>
1954
+ </xs:element>
1955
+ <xs:element name="Burner-Control" type="SAP-BurnerControlCode"
1956
+ minOccurs="0"/>
1957
+ <xs:element name="Efficiency-Type" type="SAP-EfficiencyTypeCode"
1958
+ minOccurs="0"/>
1959
+ <xs:element name="Main-Heating-Efficiency-Winter" type="xs:decimal"
1960
+ minOccurs="0">
1961
+ <xs:annotation>
1962
+ <xs:documentation>To be used if main heating data is manufacturer
1963
+ declaration and Efficiency-Type is winter and summer.
1964
+ </xs:documentation>
1965
+ </xs:annotation>
1966
+ </xs:element>
1967
+ <xs:element name="Main-Heating-Efficiency-Summer" type="xs:decimal"
1968
+ minOccurs="0">
1969
+ <xs:annotation>
1970
+ <xs:documentation>To be used if main heating data is manufacturer
1971
+ declaration and Efficiency-Type is winter and summer.
1972
+ </xs:documentation>
1973
+ </xs:annotation>
1974
+ </xs:element>
1975
+ <xs:element name="Main-Heating-Efficiency" type="xs:decimal"
1976
+ minOccurs="0">
1977
+ <xs:annotation>
1978
+ <xs:documentation>If main heating is any system other than heat
1979
+ network.
1980
+ </xs:documentation>
1981
+ </xs:annotation>
1982
+ </xs:element>
1983
+ <xs:element name="Main-Heating-System-Type" type="xs:string"
1984
+ minOccurs="0">
1985
+ <xs:annotation>
1986
+ <xs:documentation>Main heating system type or technology, for e.g.,
1987
+ combi boiler, air source heat pump, etc.
1988
+ </xs:documentation>
1989
+ </xs:annotation>
1990
+ </xs:element>
1991
+ <xs:element name="Has-FGHRS" type="xs:boolean" default="false"
1992
+ minOccurs="0">
1993
+ <xs:annotation>
1994
+ <xs:documentation>Flue Gas Heat Recovery System.</xs:documentation>
1995
+ </xs:annotation>
1996
+ </xs:element>
1997
+ <xs:element name="FGHRS-Index-Number" type="xs:nonNegativeInteger"
1998
+ minOccurs="0">
1999
+ <xs:annotation>
2000
+ <xs:documentation>FGHRS index number; only if FGHRS.
2001
+ </xs:documentation>
2002
+ </xs:annotation>
2003
+ </xs:element>
2004
+ <xs:element name="FGHRS-Energy-Source" type="SAP-Energy-Source"
2005
+ minOccurs="0"/>
2006
+ <xs:element name="Main-Heating-Declared-Values"
2007
+ type="Heating-Declared-Values" minOccurs="0"/>
2008
+ <xs:element name="Storage-Heaters" type="Storage-Heaters" minOccurs="0"/>
2009
+ <xs:element name="Emitter-Temperature" type="EmitterTemperatureCode"
2010
+ minOccurs="0">
2011
+ <xs:annotation>
2012
+ <xs:documentation>Gas and oil boilers and heat pump from database: 0,
2013
+ 1, 3 or 4
2014
+ Other heat pump 0, 2 or 4.
2015
+ Other systems NA.
2016
+ </xs:documentation>
2017
+ </xs:annotation>
2018
+ </xs:element>
2019
+ <xs:element name="MCS-Installed-Heat-Pump" type="xs:boolean"
2020
+ minOccurs="0">
2021
+ <xs:annotation>
2022
+ <xs:documentation>Whether heat pump was installed under the
2023
+ Microgeneration Certification Scheme.
2024
+ </xs:documentation>
2025
+ </xs:annotation>
2026
+ </xs:element>
2027
+ <xs:element name="Central-Heating-Pump-Age" type="PumpAge" minOccurs="0">
2028
+ <xs:annotation>
2029
+ <xs:documentation>Included for systems with a central heating pump,
2030
+ i.e. wet system.
2031
+ </xs:documentation>
2032
+ </xs:annotation>
2033
+ </xs:element>
2034
+ <xs:element name="Control-Index-Number" type="xs:positiveInteger"
2035
+ minOccurs="0">
2036
+ <xs:annotation>
2037
+ <xs:documentation>The ID of the controller from the product
2038
+ database.
2039
+ </xs:documentation>
2040
+ </xs:annotation>
2041
+ </xs:element>
2042
+ <xs:element name="Heating-Controller-Function" type="xs:string"
2043
+ minOccurs="0"/>
2044
+ <xs:element name="Heating-Controller-Ecodesign-Class" type="xs:string"
2045
+ minOccurs="0"/>
2046
+ <xs:element name="Heating-Controller-Manufacturer" type="xs:string"
2047
+ minOccurs="0"/>
2048
+ <xs:element name="Heating-Controller-Model" type="xs:string"
2049
+ minOccurs="0"/>
2050
+ </xs:all>
2051
+ </xs:complexType>
2052
+ <xs:element name="Main-Heating-Details" type="Main-Heating-Details"/>
2053
+ <xs:complexType name="Main-Heating-Details">
2054
+ <xs:sequence>
2055
+ <xs:element name="Main-Heating" type="Main-Heating" maxOccurs="2"/>
2056
+ </xs:sequence>
2057
+ </xs:complexType>
2058
+ <xs:element name="Community-Heat-Source" type="Community-Heat-Source"/>
2059
+ <xs:complexType name="Community-Heat-Source">
2060
+ <xs:all>
2061
+ <xs:element name="Heat-Source-Type" type="SAP-HeatSourceTypeCode"/>
2062
+ <xs:element name="Heat-Fraction" type="xs:decimal">
2063
+ <xs:annotation>
2064
+ <xs:documentation>Fraction of heat for the system provided by this
2065
+ heat source.
2066
+ </xs:documentation>
2067
+ </xs:annotation>
2068
+ </xs:element>
2069
+ <xs:element name="Fuel-Type" type="HeatingFuelTypeCode"/>
2070
+ <xs:element name="PCDF-Fuel-Index" type="xs:positiveInteger"
2071
+ minOccurs="0"/>
2072
+ <xs:element name="Heat-Efficiency" type="xs:decimal">
2073
+ <xs:annotation>
2074
+ <xs:documentation>Heat efficiency in %.</xs:documentation>
2075
+ </xs:annotation>
2076
+ </xs:element>
2077
+ <xs:element name="Power-Efficiency" type="xs:decimal" minOccurs="0">
2078
+ <xs:annotation>
2079
+ <xs:documentation>Power efficiency in %. Include when heat source is
2080
+ CHP.
2081
+ </xs:documentation>
2082
+ </xs:annotation>
2083
+ </xs:element>
2084
+ <xs:element name="Description" type="xs:string" minOccurs="0"/>
2085
+ <xs:element name="CHP-Electricity-Generation"
2086
+ type="SAP-CHPElectricityGenerationCode" minOccurs="0">
2087
+ <xs:annotation>
2088
+ <xs:documentation>CHP Electricity generation options from table 12f.
2089
+ </xs:documentation>
2090
+ </xs:annotation>
2091
+ </xs:element>
2092
+ </xs:all>
2093
+ </xs:complexType>
2094
+ <xs:element name="Community-Heat-Sources" type="Community-Heat-Sources"/>
2095
+ <xs:complexType name="Community-Heat-Sources">
2096
+ <xs:sequence>
2097
+ <xs:element name="Community-Heat-Source" type="Community-Heat-Source"
2098
+ maxOccurs="5"/>
2099
+ </xs:sequence>
2100
+ </xs:complexType>
2101
+ <xs:element name="Air-Change-Rates" type="Air-Change-Rates"/>
2102
+ <xs:complexType name="Air-Change-Rates">
2103
+ <xs:sequence>
2104
+ <xs:element name="Air-Change-Rate" type="Air-Change-Rate" minOccurs="12"
2105
+ maxOccurs="12"/>
2106
+ </xs:sequence>
2107
+ </xs:complexType>
2108
+ <xs:element name="Air-Change-Rate" type="Air-Change-Rate"/>
2109
+ <xs:complexType name="Air-Change-Rate">
2110
+ <xs:all>
2111
+ <xs:element name="Air-Change-Rate-Month" type="AirChangeRateMonth"/>
2112
+ <xs:element name="Air-Change-Rate-Value" type="xs:decimal">
2113
+ <xs:annotation>
2114
+ <xs:documentation>Air change rate in month.</xs:documentation>
2115
+ </xs:annotation>
2116
+ </xs:element>
2117
+ </xs:all>
2118
+ </xs:complexType>
2119
+ <xs:element name="Hydro-Electric-Generation-Months"
2120
+ type="Hydro-Electric-Generation-Months"/>
2121
+ <xs:complexType name="Hydro-Electric-Generation-Months">
2122
+ <xs:sequence>
2123
+ <xs:element name="Hydro-Electric-Generation-Month"
2124
+ type="Hydro-Electric-Generation-Month" minOccurs="12"
2125
+ maxOccurs="12"/>
2126
+ </xs:sequence>
2127
+ </xs:complexType>
2128
+ <xs:element name="Hydro-Electric-Generation-Month"
2129
+ type="Hydro-Electric-Generation-Month"/>
2130
+ <xs:complexType name="Hydro-Electric-Generation-Month">
2131
+ <xs:all>
2132
+ <xs:element name="Hydro-Month" type="HydroElecMonth"/>
2133
+ <xs:element name="Hydro-Value" type="xs:decimal">
2134
+ <xs:annotation>
2135
+ <xs:documentation>Hydro electricity in kWh in month.
2136
+ </xs:documentation>
2137
+ </xs:annotation>
2138
+ </xs:element>
2139
+ </xs:all>
2140
+ </xs:complexType>
2141
+ <xs:element name="PV-Array" type="PV-Array"/>
2142
+ <xs:complexType name="PV-Array">
2143
+ <xs:all>
2144
+ <xs:element name="Peak-Power" type="Measurement">
2145
+ <xs:annotation>
2146
+ <xs:documentation>Peak kW of photovoltaics (PVs) (kWp); 0.0 if none.
2147
+ </xs:documentation>
2148
+ </xs:annotation>
2149
+ </xs:element>
2150
+ <xs:element name="Orientation" type="SAP-CompassDirectionCode"
2151
+ minOccurs="0">
2152
+ <xs:annotation>
2153
+ <xs:documentation>PV orientation; only if peak kWp &gt; 0.
2154
+ </xs:documentation>
2155
+ </xs:annotation>
2156
+ </xs:element>
2157
+ <xs:element name="Pitch" type="SAP-VerticalPitchCode" minOccurs="0">
2158
+ <xs:annotation>
2159
+ <xs:documentation>PV pitch; only if peak kWp &gt; 0.
2160
+ </xs:documentation>
2161
+ </xs:annotation>
2162
+ </xs:element>
2163
+ <xs:element name="Overshading" type="SAP-SolarCollectorOvershadingCode"
2164
+ minOccurs="0">
2165
+ <xs:annotation>
2166
+ <xs:documentation>PV overshading; only if peak kWp &gt; 0 and no MCS
2167
+ certificate.
2168
+ </xs:documentation>
2169
+ </xs:annotation>
2170
+ </xs:element>
2171
+ <xs:element name="MCS-Certificate" type="xs:boolean" default="false"
2172
+ minOccurs="0">
2173
+ <xs:annotation>
2174
+ <xs:documentation>Does the installation have a MCS certificate.
2175
+ </xs:documentation>
2176
+ </xs:annotation>
2177
+ </xs:element>
2178
+ <xs:element name="MCS-Certificate-Reference" type="xs:string"
2179
+ minOccurs="0">
2180
+ <xs:annotation>
2181
+ <xs:documentation>MCS certificate reference number</xs:documentation>
2182
+ </xs:annotation>
2183
+ </xs:element>
2184
+ <xs:element name="PV-Panel-Manufacturer-Name" type="xs:string"
2185
+ minOccurs="0">
2186
+ <xs:annotation>
2187
+ <xs:documentation>Manufacturer of PV panels</xs:documentation>
2188
+ </xs:annotation>
2189
+ </xs:element>
2190
+ <xs:element name="Overshading-MCS" type="xs:decimal" minOccurs="0">
2191
+ <xs:annotation>
2192
+ <xs:documentation>Overshading factor calculated according to MCS.
2193
+ </xs:documentation>
2194
+ </xs:annotation>
2195
+ </xs:element>
2196
+ </xs:all>
2197
+ </xs:complexType>
2198
+ <xs:element name="PV-Arrays" type="PV-Arrays"/>
2199
+ <xs:complexType name="PV-Arrays">
2200
+ <xs:sequence>
2201
+ <xs:element name="PV-Array" type="PV-Array" maxOccurs="3"/>
2202
+ </xs:sequence>
2203
+ </xs:complexType>
2204
+ <xs:element name="Wind-Turbine" type="Wind-Turbine"/>
2205
+ <xs:complexType name="Wind-Turbine">
2206
+ <xs:all>
2207
+ <xs:element name="Wind-Turbine-Manufacturer-Name" type="xs:string"
2208
+ minOccurs="0">
2209
+ <xs:annotation>
2210
+ <xs:documentation>Wind turbine manufacturer name.</xs:documentation>
2211
+ </xs:annotation>
2212
+ </xs:element>
2213
+ <xs:element name="Wind-Turbine-Certificate" type="xs:string"
2214
+ minOccurs="0">
2215
+ <xs:annotation>
2216
+ <xs:documentation>Wind turbine certificate.</xs:documentation>
2217
+ </xs:annotation>
2218
+ </xs:element>
2219
+ <xs:element name="Wind-Turbine-Rotor-Diameter" type="Measurement">
2220
+ <xs:annotation>
2221
+ <xs:documentation>Wind turbine rotor diameter in metres; only if wind
2222
+ turbine.
2223
+ </xs:documentation>
2224
+ </xs:annotation>
2225
+ </xs:element>
2226
+ <xs:element name="Wind-Turbine-Hub-Height" type="Measurement">
2227
+ <xs:annotation>
2228
+ <xs:documentation>Wind turbine hub height above building in metres;
2229
+ only if wind turbine.
2230
+ </xs:documentation>
2231
+ </xs:annotation>
2232
+ </xs:element>
2233
+ </xs:all>
2234
+ </xs:complexType>
2235
+ <xs:element name="Wind-Turbines" type="Wind-Turbines"/>
2236
+ <xs:complexType name="Wind-Turbines">
2237
+ <xs:sequence>
2238
+ <xs:element name="Wind-Turbine" type="Wind-Turbine" maxOccurs="99"/>
2239
+ </xs:sequence>
2240
+ </xs:complexType>
2241
+ <xs:element name="Energy-Feature" type="Energy-Feature"/>
2242
+ <xs:complexType name="Energy-Feature">
2243
+ <xs:all>
2244
+ <xs:element name="Energy-Saved-Or-Generated" type="Measurement">
2245
+ <xs:annotation>
2246
+ <xs:documentation>Energy saved or generated in kWh/year.
2247
+ </xs:documentation>
2248
+ </xs:annotation>
2249
+ </xs:element>
2250
+ <xs:element name="Saved-Or-Generated-Fuel" type="HeatingFuelTypeCode"
2251
+ minOccurs="0"/>
2252
+ <xs:element name="Energy-Used" type="Measurement">
2253
+ <xs:annotation>
2254
+ <xs:documentation>Energy used in kWh/year.</xs:documentation>
2255
+ </xs:annotation>
2256
+ </xs:element>
2257
+ <xs:element name="Energy-Used-Fuel" type="HeatingFuelTypeCode"
2258
+ minOccurs="0"/>
2259
+ <xs:element name="Air-Change-Rates" type="Air-Change-Rates" minOccurs="0">
2260
+ <xs:annotation>
2261
+ <xs:documentation>For Appendix Q procedure that provides air change
2262
+ rates. Only one Special Feature can have data on air change rates.
2263
+ </xs:documentation>
2264
+ </xs:annotation>
2265
+ </xs:element>
2266
+ </xs:all>
2267
+ </xs:complexType>
2268
+ <xs:element name="Emission-Feature" type="Emission-Feature"/>
2269
+ <xs:complexType name="Emission-Feature">
2270
+ <xs:all>
2271
+ <xs:element name="Emissions-Saved" type="Measurement">
2272
+ <xs:annotation>
2273
+ <xs:documentation>Emissions saved in kg/year.</xs:documentation>
2274
+ </xs:annotation>
2275
+ </xs:element>
2276
+ <xs:element name="Emissions-Created" type="Measurement">
2277
+ <xs:annotation>
2278
+ <xs:documentation>Additional emissions in kg/year.</xs:documentation>
2279
+ </xs:annotation>
2280
+ </xs:element>
2281
+ </xs:all>
2282
+ </xs:complexType>
2283
+ <xs:element name="Solar-Heating-Details" type="Solar-Heating-Details"/>
2284
+ <xs:complexType name="Solar-Heating-Details">
2285
+ <xs:all>
2286
+ <xs:element name="Solar-Heating-Collector-Manufacturer" type="xs:string"
2287
+ minOccurs="0">
2288
+ <xs:annotation>
2289
+ <xs:documentation>Panel manufacturer</xs:documentation>
2290
+ </xs:annotation>
2291
+ </xs:element>
2292
+ <xs:element name="Solar-Heating-Certificate" type="xs:string"
2293
+ minOccurs="0">
2294
+ <xs:annotation>
2295
+ <xs:documentation>Solar heating certificate</xs:documentation>
2296
+ </xs:annotation>
2297
+ </xs:element>
2298
+ <xs:element name="Solar-Panel-Aperture-Area" type="Measurement">
2299
+ <xs:annotation>
2300
+ <xs:documentation>Panel aperture area in square metres.
2301
+ </xs:documentation>
2302
+ </xs:annotation>
2303
+ </xs:element>
2304
+ <xs:element name="Solar-Panel-Collector-Type"
2305
+ type="SAP-SolarCollectorTypeCode">
2306
+ <xs:annotation>
2307
+ <xs:documentation>Type of solar panel collector.</xs:documentation>
2308
+ </xs:annotation>
2309
+ </xs:element>
2310
+ <xs:element name="Solar-Panel-Collector-Data-Source"
2311
+ type="SAP-SolarCollectorDataSourceCode">
2312
+ <xs:annotation>
2313
+ <xs:documentation>Source of solar panel collector data.
2314
+ </xs:documentation>
2315
+ </xs:annotation>
2316
+ </xs:element>
2317
+ <xs:element name="Solar-Panel-Collector-Zero-Loss-Efficiency"
2318
+ type="Percentage" minOccurs="0">
2319
+ <xs:annotation>
2320
+ <xs:documentation>Collector zero-loss efficiency; only if declared
2321
+ values.
2322
+ </xs:documentation>
2323
+ </xs:annotation>
2324
+ </xs:element>
2325
+ <xs:element name="Solar-Panel-Collector-Heat-Loss-Rate" type="xs:decimal"
2326
+ minOccurs="0">
2327
+ <xs:annotation>
2328
+ <xs:documentation>Collector heat loss rate; for backward compatibility
2329
+ only, do not use.
2330
+ </xs:documentation>
2331
+ </xs:annotation>
2332
+ </xs:element>
2333
+ <xs:element name="Solar-Panel-Collector-Linear-Heat-Loss-Coefficient"
2334
+ type="xs:decimal" minOccurs="0">
2335
+ <xs:annotation>
2336
+ <xs:documentation>Collector linear heat loss coefficient; only if
2337
+ declared values.
2338
+ </xs:documentation>
2339
+ </xs:annotation>
2340
+ </xs:element>
2341
+ <xs:element
2342
+ name="Solar-Panel-Collector-Second-Order-Heat-Loss-Coefficient"
2343
+ type="xs:decimal" minOccurs="0">
2344
+ <xs:annotation>
2345
+ <xs:documentation>Collector 2nd order heat loss coefficient; only if
2346
+ declared values.
2347
+ </xs:documentation>
2348
+ </xs:annotation>
2349
+ </xs:element>
2350
+ <xs:element name="Solar-Panel-Collector-Orientation"
2351
+ type="SAP-CompassDirectionCode">
2352
+ <xs:annotation>
2353
+ <xs:documentation>Collector orientation.</xs:documentation>
2354
+ </xs:annotation>
2355
+ </xs:element>
2356
+ <xs:element name="Solar-Panel-Collector-Pitch" type="SAP-VerticalPitch"/>
2357
+ <xs:element name="Solar-Panel-Collector-Overshading"
2358
+ type="SAP-SolarCollectorOvershadingCode"/>
2359
+ <xs:element name="Has-Solar-Powered-Pump" type="xs:boolean"
2360
+ default="false"/>
2361
+ <xs:element name="Is-Solar-Store-Combined-Cylinder" type="xs:boolean"
2362
+ default="false"/>
2363
+ <xs:element name="Solar-Store-Volume" type="Measurement">
2364
+ <xs:annotation>
2365
+ <xs:documentation>Dedicated solar store volume in litres.
2366
+ </xs:documentation>
2367
+ </xs:annotation>
2368
+ </xs:element>
2369
+ <xs:element name="Collector-Loop-Efficiency" type="xs:decimal"
2370
+ minOccurs="0">
2371
+ <xs:annotation>
2372
+ <xs:documentation>Collector loop efficiency; only if declared
2373
+ values.
2374
+ </xs:documentation>
2375
+ </xs:annotation>
2376
+ </xs:element>
2377
+ <xs:element name="Incidence-Angle-Modifier" type="xs:decimal"
2378
+ minOccurs="0">
2379
+ <xs:annotation>
2380
+ <xs:documentation>Incidence angle modifier; only if declared values.
2381
+ </xs:documentation>
2382
+ </xs:annotation>
2383
+ </xs:element>
2384
+ <xs:element name="Is-Community-Solar" type="xs:boolean" default="false"/>
2385
+ <xs:element name="Service-Provision" type="ServiceProvisionCode"/>
2386
+ <xs:element name="Overall-Heat-Loss" type="xs:decimal" minOccurs="0">
2387
+ <xs:annotation>
2388
+ <xs:documentation>Overall heat loss coefficient of system; only if
2389
+ declared values.
2390
+ </xs:documentation>
2391
+ </xs:annotation>
2392
+ </xs:element>
2393
+ </xs:all>
2394
+ </xs:complexType>
2395
+ <xs:element name="Instantaneous-WWHRS" type="Instantaneous-WWHRS"/>
2396
+ <xs:complexType name="Instantaneous-WWHRS">
2397
+ <xs:sequence>
2398
+ <xs:element name="WWHRS-Index-Number1" type="xs:positiveInteger"/>
2399
+ <xs:element name="WWHRS-Index-Number2" type="xs:positiveInteger"
2400
+ minOccurs="0">
2401
+ <xs:annotation>
2402
+ <xs:documentation>Omit if no second system.</xs:documentation>
2403
+ </xs:annotation>
2404
+ </xs:element>
2405
+ <xs:element name="WWHRS-Efficiency1" type="xs:decimal" minOccurs="0"/>
2406
+ <xs:element name="WWHRS-Manufacturer1" type="xs:string" minOccurs="0"/>
2407
+ <xs:element name="WWHRS-Model1" type="xs:string" minOccurs="0"/>
2408
+ <xs:element name="WWHRS-Efficiency2" type="xs:decimal" minOccurs="0"/>
2409
+ <xs:element name="WWHRS-Manufacturer2" type="xs:string" minOccurs="0"/>
2410
+ <xs:element name="WWHRS-Model2" type="xs:string" minOccurs="0"/>
2411
+ </xs:sequence>
2412
+ </xs:complexType>
2413
+ <xs:element name="Storage-WWHRS" type="Storage-WWHRS"/>
2414
+ <xs:complexType name="Storage-WWHRS">
2415
+ <xs:all>
2416
+ <xs:element name="WWHRS-Index-Number" type="xs:positiveInteger"/>
2417
+ <xs:element name="WWHRS-Store-Volume" type="Measurement">
2418
+ <xs:annotation>
2419
+ <xs:documentation>Dedicated store volume in litres.</xs:documentation>
2420
+ </xs:annotation>
2421
+ </xs:element>
2422
+ <xs:element name="Storage-WWHRS-Efficiency" type="xs:decimal"
2423
+ minOccurs="0"/>
2424
+ <xs:element name="Storage-WWHRS-Manufacturer" type="xs:string"
2425
+ minOccurs="0"/>
2426
+ <xs:element name="Storage-WWHRS-Model" type="xs:string" minOccurs="0"/>
2427
+ </xs:all>
2428
+ </xs:complexType>
2429
+ <xs:element name="Shower-Outlets" type="Shower-Outlets"/>
2430
+ <xs:complexType name="Shower-Outlets">
2431
+ <xs:annotation>
2432
+ <xs:documentation>Shower outlets present in the dwelling. If there are
2433
+ more than 5 then only include the 5 with the highest flow rates used.
2434
+ </xs:documentation>
2435
+ </xs:annotation>
2436
+ <xs:sequence>
2437
+ <xs:element name="Shower-Outlet" type="Shower-Outlet" maxOccurs="5"/>
2438
+ </xs:sequence>
2439
+ </xs:complexType>
2440
+ <xs:element name="Shower-Outlet" type="Shower-Outlet"/>
2441
+ <xs:complexType name="Shower-Outlet">
2442
+ <xs:annotation>
2443
+ <xs:documentation>Various details for each shower outlet.
2444
+ </xs:documentation>
2445
+ </xs:annotation>
2446
+ <xs:all>
2447
+ <xs:element name="Shower-Outlet-Type" type="ShowerOutletTypeCode">
2448
+ <xs:annotation>
2449
+ <xs:documentation>Hot water type for this shower outlet.
2450
+ </xs:documentation>
2451
+ </xs:annotation>
2452
+ </xs:element>
2453
+ <xs:element name="Shower-Flow-Rate" type="Measurement" minOccurs="0">
2454
+ <xs:annotation>
2455
+ <xs:documentation>The flow rate. Only when a shower is not
2456
+ instantaneous electric. Leave blank if NO flow limiter fitted.
2457
+ </xs:documentation>
2458
+ </xs:annotation>
2459
+ </xs:element>
2460
+ <xs:element name="Shower-Power" type="Measurement" minOccurs="0">
2461
+ <xs:annotation>
2462
+ <xs:documentation>The shower power, only if shower outlet type is
2463
+ instantaneous electric.
2464
+ </xs:documentation>
2465
+ </xs:annotation>
2466
+ </xs:element>
2467
+ <xs:element name="Shower-WWHRS" type="ShowerWWHRSCode">
2468
+ <xs:annotation>
2469
+ <xs:documentation>The WWHRS with which the shower is connected. If
2470
+ shower outlet type is instantaneous electric shower then only a
2471
+ storage WWHRS can be selected or none.
2472
+ </xs:documentation>
2473
+ </xs:annotation>
2474
+ </xs:element>
2475
+ </xs:all>
2476
+ </xs:complexType>
2477
+ <xs:element name="Heating-Declared-Values" type="Heating-Declared-Values"/>
2478
+ <xs:complexType name="Heating-Declared-Values">
2479
+ <xs:all>
2480
+ <xs:element name="Efficiency" type="Percentage"/>
2481
+ <xs:element name="Make-Model" type="xs:string"/>
2482
+ <xs:element name="Test-Method" type="xs:string"/>
2483
+ </xs:all>
2484
+ </xs:complexType>
2485
+ <xs:element name="Storage-Heater"/>
2486
+ <xs:complexType name="Storage-Heater">
2487
+ <xs:all>
2488
+ <xs:element name="Number-Of-Heaters" type="xs:positiveInteger">
2489
+ <xs:annotation>
2490
+ <xs:documentation>The number of storage heaters with this index
2491
+ number.
2492
+ </xs:documentation>
2493
+ </xs:annotation>
2494
+ </xs:element>
2495
+ <xs:element name="Index-Number" type="xs:positiveInteger">
2496
+ <xs:annotation>
2497
+ <xs:documentation>The index number of the heater from the product
2498
+ database.
2499
+ </xs:documentation>
2500
+ </xs:annotation>
2501
+ </xs:element>
2502
+ <xs:element name="High-Heat-Retention" type="xs:boolean">
2503
+ <xs:annotation>
2504
+ <xs:documentation>Whether heater is high heat retention type.
2505
+ </xs:documentation>
2506
+ </xs:annotation>
2507
+ </xs:element>
2508
+ </xs:all>
2509
+ </xs:complexType>
2510
+ <xs:element name="Storage-Heaters"/>
2511
+ <xs:complexType name="Storage-Heaters">
2512
+ <xs:sequence>
2513
+ <xs:element name="Storage-Heater" type="Storage-Heater" maxOccurs="4"/>
2514
+ </xs:sequence>
2515
+ </xs:complexType>
2516