epb_view_models 2.0.2 → 2.0.4
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- checksums.yaml +4 -4
- data/.ruby-version +1 -1
- data/Gemfile +1 -1
- data/Gemfile.lock +1 -1
- data/api/schemas/xml/RdSAP-Schema-21.0.0/RdSAP/ExternalDefinitions.xml +67 -31
- data/api/schemas/xml/RdSAP-Schema-21.0.0/RdSAP/Templates/EPC-Certificate.xsd +0 -1
- data/api/schemas/xml/RdSAP-Schema-21.0.0/RdSAP/Templates/EPC-CollectedData.xsd +62 -14
- data/api/schemas/xml/RdSAP-Schema-21.0.0/RdSAP/UDT/EPC-Domains.xsd +35 -0
- data/api/schemas/xml/RdSAP-Schema-21.0.0/RdSAP/UDT/SAP-Domains.xsd +3333 -3264
- data/lib/epb_view_models.rb +1 -1
- data/lib/helper/ac_report_extraction.rb +1 -1
- metadata +3 -3
checksums.yaml
CHANGED
@@ -1,7 +1,7 @@
|
|
1
1
|
---
|
2
2
|
SHA256:
|
3
|
-
metadata.gz:
|
4
|
-
data.tar.gz:
|
3
|
+
metadata.gz: 17a71b40dc0180b1d1a57a523310aad15194a9eb36f3294308834913ed738b0e
|
4
|
+
data.tar.gz: 9f5809ec294a584d9cb2e98c33765106ed3ee72d6fc16ee037ae03a828b7fbb2
|
5
5
|
SHA512:
|
6
|
-
metadata.gz:
|
7
|
-
data.tar.gz:
|
6
|
+
metadata.gz: 642347a583549d71b62ca6395bfb816df36e682cb4a1f011329b9f02d3fcabd4f0f7eab933bc892d5be671602a12d6c82aa1d5169b70ded447a390ca0c5e6a74
|
7
|
+
data.tar.gz: 450162cffd2115bfbdcdd5f16f5190fdd32fc7dec78a9d22e9c263e9bc63e968f16a9f7451ea964d6f895fa9705a907b6447ed76fc00af1138a1699ded4439e5
|
data/.ruby-version
CHANGED
@@ -1 +1 @@
|
|
1
|
-
3.
|
1
|
+
3.3.2
|
data/Gemfile
CHANGED
data/Gemfile.lock
CHANGED
@@ -1,8 +1,8 @@
|
|
1
1
|
<?xml version="1.0" encoding="UTF-8"?>
|
2
2
|
<!--EPC Recommendations, RdSAP Addenda, Transaction Types, Tenures and Related Party Disclosure-->
|
3
3
|
<EPC:ExternalDefinitions xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="EPC ExternalDefinitions.xsd" xmlns:EPC="EPC">
|
4
|
-
<Revision-Number>
|
5
|
-
<Revision-Date>
|
4
|
+
<Revision-Number>8.0</Revision-Number>
|
5
|
+
<Revision-Date>2024-03-13</Revision-Date>
|
6
6
|
<Country>
|
7
7
|
<Country-Code>EAW</Country-Code>
|
8
8
|
<Average-SAP-Rating>60</Average-SAP-Rating>
|
@@ -240,6 +240,24 @@
|
|
240
240
|
<Improvement-Description language="1">Gas condensing boiler</Improvement-Description>
|
241
241
|
<Improvement-Description language="2">Bwyler cyddwyso nwy</Improvement-Description>
|
242
242
|
</Recommendation>
|
243
|
+
<Recommendation>
|
244
|
+
<Improvement-Number>72</Improvement-Number>
|
245
|
+
<Improvement-Summary language="1">Add PV battery</Improvement-Summary>
|
246
|
+
<Improvement-Summary language="2">Newid system wresogi i fwyler cyddwyso nwy</Improvement-Summary>
|
247
|
+
<Improvement-Heading language="1">Gas condensing boiler</Improvement-Heading>
|
248
|
+
<Improvement-Heading language="2">Bwyler cyddwyso nwy</Improvement-Heading>
|
249
|
+
<Improvement-Description language="1">Gas condensing boiler</Improvement-Description>
|
250
|
+
<Improvement-Description language="2">Bwyler cyddwyso nwy</Improvement-Description>
|
251
|
+
</Recommendation>
|
252
|
+
<Recommendation>
|
253
|
+
<Improvement-Number>73</Improvement-Number>
|
254
|
+
<Improvement-Summary language="1">Add PV diverter</Improvement-Summary>
|
255
|
+
<Improvement-Summary language="2">Newid system wresogi i fwyler cyddwyso nwy</Improvement-Summary>
|
256
|
+
<Improvement-Heading language="1">Gas condensing boiler</Improvement-Heading>
|
257
|
+
<Improvement-Heading language="2">Bwyler cyddwyso nwy</Improvement-Heading>
|
258
|
+
<Improvement-Description language="1">Gas condensing boiler</Improvement-Description>
|
259
|
+
<Improvement-Description language="2">Bwyler cyddwyso nwy</Improvement-Description>
|
260
|
+
</Recommendation>
|
243
261
|
<Recommendation>
|
244
262
|
<Improvement-Number>34</Improvement-Number>
|
245
263
|
<Improvement-Summary language="1">Solar photovoltaic panels, 2.5 kWp</Improvement-Summary>
|
@@ -440,8 +458,8 @@
|
|
440
458
|
</Recommendation>
|
441
459
|
<Recommendation>
|
442
460
|
<Improvement-Number>59</Improvement-Number>
|
443
|
-
<Improvement-Summary language="1">High heat retention storage heaters and dual immersion cylinder
|
444
|
-
<Improvement-Summary language="2">Gwresogyddion storio sy’n cadw llawer o wres a silindr sydd â dau dwymwr tanddwr</Improvement-Summary>
|
461
|
+
<Improvement-Summary language="1">High heat retention storage heaters and dual immersion cylinder and dual rate meter<</Improvement-Summary>
|
462
|
+
<Improvement-Summary language="2">Gwresogyddion storio sy’n cadw llawer o wres a silindr sydd â dau dwymwr tanddwr a mesurydd cyfradd ddeuol</Improvement-Summary>
|
445
463
|
<Improvement-Heading language="1">High heat retention storage heaters</Improvement-Heading>
|
446
464
|
<Improvement-Heading language="2">Gwresogyddion storio sy’n cadw llawer o wres</Improvement-Heading>
|
447
465
|
<Improvement-Description language="1">High heat retention storage heaters</Improvement-Description>
|
@@ -458,8 +476,8 @@
|
|
458
476
|
</Recommendation>
|
459
477
|
<Recommendation>
|
460
478
|
<Improvement-Number>61</Improvement-Number>
|
461
|
-
<Improvement-Summary language="1">High heat retention storage heaters and dual immersion cylinder</Improvement-Summary>
|
462
|
-
<Improvement-Summary language="2">Gwresogyddion storio sy’n cadw llawer o wres a silindr sydd â dau dwymwr tanddwr</Improvement-Summary>
|
479
|
+
<Improvement-Summary language="1">High heat retention storage heaters and dual immersion cylinder and dual rate meter</Improvement-Summary>
|
480
|
+
<Improvement-Summary language="2">Gwresogyddion storio sy’n cadw llawer o wres a silindr sydd â dau dwymwr tanddwr a mesurydd cyfradd ddeuol</Improvement-Summary>
|
463
481
|
<Improvement-Heading language="1">High heat retention storage heaters</Improvement-Heading>
|
464
482
|
<Improvement-Heading language="2">Gwresogyddion storio sy’n cadw llawer o wres</Improvement-Heading>
|
465
483
|
<Improvement-Description language="1">High heat retention storage heaters</Improvement-Description>
|
@@ -467,14 +485,14 @@
|
|
467
485
|
</Recommendation>
|
468
486
|
<Recommendation>
|
469
487
|
<Improvement-Number>62</Improvement-Number>
|
470
|
-
<Improvement-Summary language="1">High heat retention storage heaters</Improvement-Summary>
|
471
|
-
<Improvement-Summary language="2">Gwresogyddion storio sy’n cadw llawer o wres</Improvement-Summary>
|
488
|
+
<Improvement-Summary language="1">High heat retention storage heaters and dual rate meter</Improvement-Summary>
|
489
|
+
<Improvement-Summary language="2">Gwresogyddion storio sy’n cadw llawer o wres a mesurydd cyfradd ddeuol</Improvement-Summary>
|
472
490
|
<Improvement-Heading language="1">High heat retention storage heaters</Improvement-Heading>
|
473
491
|
<Improvement-Heading language="2">Gwresogyddion storio sy’n cadw llawer o wres</Improvement-Heading>
|
474
492
|
<Improvement-Description language="1">High heat retention storage heaters</Improvement-Description>
|
475
493
|
<Improvement-Description language="2">Gwresogyddion storio sy’n cadw llawer o wres</Improvement-Description>
|
476
494
|
</Recommendation>
|
477
|
-
|
495
|
+
<Recommendation>
|
478
496
|
<Improvement-Number>63</Improvement-Number>
|
479
497
|
<Improvement-Summary language="1">Party wall insulation</Improvement-Summary>
|
480
498
|
<Improvement-Summary language="2">Insiwleiddio muriau cyd</Improvement-Summary>
|
@@ -517,36 +535,24 @@
|
|
517
535
|
</Transaction-Type>
|
518
536
|
<Transaction-Type>
|
519
537
|
<Display-Order>6</Display-Order>
|
520
|
-
<Transaction-Code>
|
521
|
-
<Transaction-Text>
|
538
|
+
<Transaction-Code>16</Transaction-Code>
|
539
|
+
<Transaction-Text>Grant scheme</Transaction-Text>
|
522
540
|
<In-RdSAP>true</In-RdSAP>
|
523
541
|
</Transaction-Type>
|
524
542
|
<Transaction-Type>
|
525
543
|
<Display-Order>7</Display-Order>
|
526
|
-
<Transaction-Code>
|
527
|
-
<Transaction-Text>
|
544
|
+
<Transaction-Code>17</Transaction-Code>
|
545
|
+
<Transaction-Text>Non-grant scheme</Transaction-Text>
|
528
546
|
<In-RdSAP>true</In-RdSAP>
|
529
547
|
</Transaction-Type>
|
530
548
|
<Transaction-Type>
|
531
549
|
<Display-Order>8</Display-Order>
|
532
|
-
<Transaction-Code>
|
533
|
-
<Transaction-Text>
|
550
|
+
<Transaction-Code>15</Transaction-Code>
|
551
|
+
<Transaction-Text>Re-mortgaging</Transaction-Text>
|
534
552
|
<In-RdSAP>true</In-RdSAP>
|
535
553
|
</Transaction-Type>
|
536
554
|
<Transaction-Type>
|
537
555
|
<Display-Order>9</Display-Order>
|
538
|
-
<Transaction-Code>12</Transaction-Code>
|
539
|
-
<Transaction-Text>RHI application</Transaction-Text>
|
540
|
-
<In-RdSAP>true</In-RdSAP>
|
541
|
-
</Transaction-Type>
|
542
|
-
<Transaction-Type>
|
543
|
-
<Display-Order>10</Display-Order>
|
544
|
-
<Transaction-Code>13</Transaction-Code>
|
545
|
-
<Transaction-Text>ECO assessment</Transaction-Text>
|
546
|
-
<In-RdSAP>true</In-RdSAP>
|
547
|
-
</Transaction-Type>
|
548
|
-
<Transaction-Type>
|
549
|
-
<Display-Order>11</Display-Order>
|
550
556
|
<Transaction-Code>5</Transaction-Code>
|
551
557
|
<Transaction-Text>None of the above</Transaction-Text>
|
552
558
|
<In-RdSAP>true</In-RdSAP>
|
@@ -674,7 +680,7 @@
|
|
674
680
|
<Improvement-Summary-2 language="1">Internal or external wall insulation</Improvement-Summary-2>
|
675
681
|
<Improvement-Heading language="1">Internal or external wall insulation</Improvement-Heading>
|
676
682
|
<Improvement-Description language="1">Internal or external wall insulation involves adding a layer of insulation to either the inside or the outside surface of the external walls, which reduces heat loss and lowers fuel bills. As it is more expensive than cavity wall insulation it is only recommended for walls without a cavity, or where for technical reasons a cavity cannot be filled. Internal insulation, known as dry-lining, is where a layer of insulation is fixed to the inside surface of external walls; this type of insulation is best applied when rooms require redecorating. External solid wall insulation is the application of an insulant and a weather-protective finish to the outside of the wall. This may improve the look of the home, particularly where existing brickwork or rendering is poor, and will provide long-lasting weather protection. Further information can be obtained from the National Insulation Association (www.nationalinsulationassociation.org.uk). It should be noted that a building warrant is required for the installation of external wall insulation. Planning permission may also be required and that building regulations apply to external insulation so it is best to check with your local authority on both issues.
|
677
|
-
|
683
|
+
</Improvement-Description>
|
678
684
|
</Recommendation>
|
679
685
|
<Recommendation>
|
680
686
|
<Improvement-Number>8</Improvement-Number>
|
@@ -992,7 +998,7 @@
|
|
992
998
|
<Improvement-Heading language="1">High heat retention storage heaters</Improvement-Heading>
|
993
999
|
<Improvement-Description language="1">Modern storage heaters are less expensive to run than the direct acting, on-peak heating system in the property. A dual-rate electricity supply is required to provide the off-peak electricity that these heaters use; this is easily obtained by contacting the energy supplier. Ask for a quotation for high heat retention with automatic charge and output controls. Installations should be in accordance with the national wiring standards. Building regulations generally apply to this work and a building warrant may be required, so it is best to obtain advice from your local authority building standards department and from a qualified electrical heating engineer. Ask the heating engineer to explain the options, which might also include switching to other forms of electric heating.</Improvement-Description>
|
994
1000
|
</Recommendation>
|
995
|
-
|
1001
|
+
<Recommendation>
|
996
1002
|
<Improvement-Number>63</Improvement-Number>
|
997
1003
|
<Improvement-Summary language="1">Party wall insulation</Improvement-Summary>
|
998
1004
|
<Improvement-Summary-2 language="1">Party wall insulation</Improvement-Summary-2>
|
@@ -1440,7 +1446,7 @@
|
|
1440
1446
|
<Improvement-Heading language="1">High heat retention storage heaters</Improvement-Heading>
|
1441
1447
|
<Improvement-Description language="1">Modern storage heaters are less expensive to run than the direct acting, on-peak heating system in the property. A dual-rate electricity supply is required to provide the off-peak electricity that these heaters use; this is easily obtained by contacting the energy supplier. Ask for a quotation for high heat retention heaters with automatic charge and output controls. As installations should be in accordance with the national wiring standards, only a qualified electrician should carry out the installation. It is best to obtain advice from a qualified electrical heating engineer. Ask a qualified electrical heating engineer to explain the options, which might also include switching to other forms of electric heating.</Improvement-Description>
|
1442
1448
|
</Recommendation>
|
1443
|
-
|
1449
|
+
<Recommendation>
|
1444
1450
|
<Improvement-Number>63</Improvement-Number>
|
1445
1451
|
<Improvement-Summary language="1">Party wall insulation</Improvement-Summary>
|
1446
1452
|
<Improvement-Heading language="1">Party wall insulation</Improvement-Heading>
|
@@ -1567,9 +1573,39 @@
|
|
1567
1573
|
<Addendum-Text language="1">The dwelling uses a type of fuel that is not included in the available options. The nearest equivalent fuel type was used for the assessment.</Addendum-Text>
|
1568
1574
|
<Addendum-Text language="2">Nid yw’r math o danwydd y mae’r anheddiad yn ei ddefnyddio wedi ei restru yn yr opsiynau sydd ar gael. Defnyddiwyd y math cyfatebol tebycaf o danwydd ar gyfer yr asesiad.</Addendum-Text>
|
1569
1575
|
</Addendum>
|
1576
|
+
<Addendum>
|
1577
|
+
<Addendum-Number>13</Addendum-Number>
|
1578
|
+
<Circumstances>13. Dwelling has a special energy saving feature </Circumstances>
|
1579
|
+
<Addendum-Text language="1">The dwelling has a special energy saving feature which is recognised in the assessment, but its impact on the savings shown for improvement measures is ignored.</Addendum-Text>
|
1580
|
+
<Addendum-Text language="2">[Welsh translation of the above]</Addendum-Text>
|
1581
|
+
</Addendum>
|
1570
1582
|
<Addendum>
|
1571
1583
|
<Addendum-Number>14</Addendum-Number>
|
1572
|
-
<Circumstances>14.
|
1584
|
+
<Circumstances>14. Conservation area </Circumstances>
|
1585
|
+
<Addendum-Text language="1">Conservation area.</Addendum-Text>
|
1586
|
+
<Addendum-Text language="2">[Welsh translation of the above]</Addendum-Text>
|
1587
|
+
</Addendum>
|
1588
|
+
<Addendum>
|
1589
|
+
<Addendum-Number>15</Addendum-Number>
|
1590
|
+
<Circumstances>15. PV recommended </Circumstances>
|
1591
|
+
<Addendum-Text language="1">When considering the PV installation consider installing PV battery and PV diverter for water heating.</Addendum-Text>
|
1592
|
+
<Addendum-Text language="2">[Welsh translation of the above]</Addendum-Text>
|
1593
|
+
</Addendum>
|
1594
|
+
<Addendum>
|
1595
|
+
<Addendum-Number>16</Addendum-Number>
|
1596
|
+
<Circumstances>16. PV-independent battery storage present </Circumstances>
|
1597
|
+
<Addendum-Text language="1">The dwelling has a special energy saving feature which is recognised in the assessment, but its impact on the savings shown for improvement measures is ignored.</Addendum-Text>
|
1598
|
+
<Addendum-Text language="2">[Welsh translation of the above]</Addendum-Text>
|
1599
|
+
</Addendum>
|
1600
|
+
<Addendum>
|
1601
|
+
<Addendum-Number>17</Addendum-Number>
|
1602
|
+
<Circumstances>17. 'Phase changing' heat storage present </Circumstances>
|
1603
|
+
<Addendum-Text language="1">The dwelling has a special energy saving feature which is recognised in the assessment, but its impact on the savings shown for improvement measures is ignored.</Addendum-Text>
|
1604
|
+
<Addendum-Text language="2">[Welsh translation of the above]</Addendum-Text>
|
1605
|
+
</Addendum>
|
1606
|
+
<Addendum>
|
1607
|
+
<Addendum-Number>18</Addendum-Number>
|
1608
|
+
<Circumstances>18. Party wall insulation </Circumstances>
|
1573
1609
|
<Addendum-Text language="1">The dwelling has a special energy saving feature which is recognised in the assessment, but its impact on the savings shown for improvement measures is ignored.</Addendum-Text>
|
1574
1610
|
<Addendum-Text language="2">[Welsh translation of the above]</Addendum-Text>
|
1575
1611
|
</Addendum>
|
@@ -226,7 +226,6 @@ The Improved Energy Ratings that result from carrying out a Suggested Improvemen
|
|
226
226
|
</xs:complexType>
|
227
227
|
</xs:element>
|
228
228
|
<xs:element name="Indicative-Cost" type="xs:string" minOccurs="0"/>
|
229
|
-
<xs:element name="Green-Deal-Category" type="GreenDealCategoryCode"/>
|
230
229
|
</xs:all>
|
231
230
|
</xs:complexType>
|
232
231
|
<xs:element name="PropertySummaryType" type="PropertySummaryType"/>
|
@@ -167,7 +167,7 @@ This is actually the type differentiator for Property but only a limited number
|
|
167
167
|
<xs:documentation>Mechanical ventilation duct insulation; if MVHR from PCDB.</xs:documentation>
|
168
168
|
</xs:annotation>
|
169
169
|
</xs:element>
|
170
|
-
<xs:element name="Mechanical-
|
170
|
+
<xs:element name="Mechanical-Vent-Duct-Insulation" type="SAP-DuctInsulationCode" minOccurs="0">
|
171
171
|
<xs:annotation>
|
172
172
|
<xs:documentation>Relevant when mechanical ventilation system is from PCDB.</xs:documentation>
|
173
173
|
</xs:annotation>
|
@@ -187,6 +187,36 @@ This is actually the type differentiator for Property but only a limited number
|
|
187
187
|
<xs:documentation>If MVHR from pcdb.</xs:documentation>
|
188
188
|
</xs:annotation>
|
189
189
|
</xs:element>
|
190
|
+
<xs:element name="Kitchen-Room-Fans-Count" type="Count" minOccurs="0">
|
191
|
+
<xs:annotation>
|
192
|
+
<xs:documentation>MEV dc, number of fans in room, kitchen; if mechanical vent data from database or manufacturer declaration (MEV dc).</xs:documentation>
|
193
|
+
</xs:annotation>
|
194
|
+
</xs:element>
|
195
|
+
<xs:element name="Non-Kitchen-Room-Fans-Count" type="Count" minOccurs="0">
|
196
|
+
<xs:annotation>
|
197
|
+
<xs:documentation>MEV dc, number of fans in room, rooms other than kitchen; if mechanical vent data from database or manufacturer declaration (MEV dc).</xs:documentation>
|
198
|
+
</xs:annotation>
|
199
|
+
</xs:element>
|
200
|
+
<xs:element name="Kitchen-Duct-Fans-Count" type="Count" minOccurs="0">
|
201
|
+
<xs:annotation>
|
202
|
+
<xs:documentation>MEV dc, number of fans via duct, kitchen; if mechanical vent data from database or manufacturer declaration (MEV dc).</xs:documentation>
|
203
|
+
</xs:annotation>
|
204
|
+
</xs:element>
|
205
|
+
<xs:element name="Non-Kitchen-Duct-Fans-Count" type="Count" minOccurs="0">
|
206
|
+
<xs:annotation>
|
207
|
+
<xs:documentation>MEV dc, number of fans via duct, rooms other than kitchen; if mechanical vent data from database or manufacturer declaration (MEV dc).</xs:documentation>
|
208
|
+
</xs:annotation>
|
209
|
+
</xs:element>
|
210
|
+
<xs:element name="Kitchen-Wall-Fans-Count" type="Count" minOccurs="0">
|
211
|
+
<xs:annotation>
|
212
|
+
<xs:documentation>MEV dc, number of fans through wall, kitchen; if mechanical vent data from database or manufacturer declaration (MEV dc).</xs:documentation>
|
213
|
+
</xs:annotation>
|
214
|
+
</xs:element>
|
215
|
+
<xs:element name="Non-Kitchen-Wall-Fans-Count" type="Count" minOccurs="0">
|
216
|
+
<xs:annotation>
|
217
|
+
<xs:documentation>MEV dc, number of fans through wall, rooms other than kitchen; if mechanical vent data from database or manufacturer declaration (MEV dc).</xs:documentation>
|
218
|
+
</xs:annotation>
|
219
|
+
</xs:element>
|
190
220
|
<xs:element name="Conservatory-Type" type="SAP-ConservatoryTypeCode">
|
191
221
|
<xs:annotation>
|
192
222
|
<xs:documentation>Type of Conservatory</xs:documentation>
|
@@ -225,6 +255,11 @@ This is actually the type differentiator for Property but only a limited number
|
|
225
255
|
<xs:documentation>Number of insulated external doors</xs:documentation>
|
226
256
|
</xs:annotation>
|
227
257
|
</xs:element>
|
258
|
+
<xs:element name="Draughtproofed-Door-Count" type="Count" minOccurs="0">
|
259
|
+
<xs:annotation>
|
260
|
+
<xs:documentation>Number of draught proofed external doors</xs:documentation>
|
261
|
+
</xs:annotation>
|
262
|
+
</xs:element>
|
228
263
|
<xs:element name="Insulated-Door-U-Value" type="xs:decimal" minOccurs="0"/>
|
229
264
|
<xs:element name="Percent-Draughtproofed">
|
230
265
|
<xs:annotation>
|
@@ -406,7 +441,12 @@ For the purpose of calculating the overall Energy Assessment for the property de
|
|
406
441
|
</xs:annotation>
|
407
442
|
</xs:element>
|
408
443
|
<xs:element name="SAP-Room-In-Roof" type="SAP-Room-In-Roof" minOccurs="0"/>
|
409
|
-
<xs:element name="SAP-Alternative-Wall" type="SAP-Alternative-Wall" minOccurs="0">
|
444
|
+
<xs:element name="SAP-Alternative-Wall-1" type="SAP-Alternative-Wall" minOccurs="0">
|
445
|
+
<xs:annotation>
|
446
|
+
<xs:documentation>Included only for building parts that have an alternative wall</xs:documentation>
|
447
|
+
</xs:annotation>
|
448
|
+
</xs:element>
|
449
|
+
<xs:element name="SAP-Alternative-Wall-2" type="SAP-Alternative-Wall" minOccurs="0">
|
410
450
|
<xs:annotation>
|
411
451
|
<xs:documentation>Included only for building parts that have an alternative wall</xs:documentation>
|
412
452
|
</xs:annotation>
|
@@ -417,7 +457,6 @@ For the purpose of calculating the overall Energy Assessment for the property de
|
|
417
457
|
<xs:element name="SAP-Alternative-Wall" type="SAP-Alternative-Wall"/>
|
418
458
|
<xs:complexType name="SAP-Alternative-Wall">
|
419
459
|
<xs:all>
|
420
|
-
<xs:element name="Alternative-Wall-Number" type="AlternativeWallCount"/>
|
421
460
|
<xs:element name="Wall-Construction" type="WallConstructionCode"/>
|
422
461
|
<xs:element name="Wall-Insulation-Type" type="WallInsulationCode"/>
|
423
462
|
<xs:element name="Wall-Area" type="Measurement"/>
|
@@ -743,17 +782,6 @@ For the purpose of calculating the overall Energy Assessment for the property de
|
|
743
782
|
<xs:all>
|
744
783
|
<xs:element name="Floor-Area" type="Measurement"/>
|
745
784
|
<xs:element name="Construction-Age-Band" type="ConstructionDateCode"/>
|
746
|
-
<xs:element name="Insulation" type="SAP-RoomInRoofInsulationCode" minOccurs="0"/>
|
747
|
-
<xs:element name="Roof-Room-Connected" type="Flag">
|
748
|
-
<xs:annotation>
|
749
|
-
<xs:documentation>Whether the roof room is connected to another building part of the same dwelling</xs:documentation>
|
750
|
-
</xs:annotation>
|
751
|
-
</xs:element>
|
752
|
-
<xs:element name="Roof-Insulation-Thickness" type="RoofInsulationThicknessCode" minOccurs="0">
|
753
|
-
<xs:annotation>
|
754
|
-
<xs:documentation>Use ND when Room-In-Roof-Details is included</xs:documentation>
|
755
|
-
</xs:annotation>
|
756
|
-
</xs:element>
|
757
785
|
<xs:element name="Room-In-Roof-Details" type="Room-In-Roof-Details" minOccurs="0">
|
758
786
|
<xs:annotation>
|
759
787
|
<xs:documentation>Omit when Room-In-Roof details not included</xs:documentation>
|
@@ -1000,6 +1028,11 @@ If the total peak power has been apportioned between different dwellings within
|
|
1000
1028
|
<xs:documentation>Mutually exclusive with U-value. Either U-value provided, or thickness.</xs:documentation>
|
1001
1029
|
</xs:annotation>
|
1002
1030
|
</xs:element>
|
1031
|
+
<xs:element name="Flat-Ceiling-Insulation-Location-1" type="RoofInsulationLocationCode" minOccurs="0">
|
1032
|
+
<xs:annotation>
|
1033
|
+
<xs:documentation>Mutually exclusive with U-value and insulation type. Either U-value provided, or insulation type or location. To enable using table 16.</xs:documentation>
|
1034
|
+
</xs:annotation>
|
1035
|
+
</xs:element>
|
1003
1036
|
<xs:element name="Flat-Ceiling-Length-2" type="Measurement" minOccurs="0"/>
|
1004
1037
|
<xs:element name="Flat-Ceiling-Height-2" type="Measurement" minOccurs="0"/>
|
1005
1038
|
<xs:element name="Flat-Ceiling-U-Value-2" type="xs:decimal" minOccurs="0"/>
|
@@ -1013,6 +1046,11 @@ If the total peak power has been apportioned between different dwellings within
|
|
1013
1046
|
<xs:documentation>Mutually exclusive with U-value. Either U-value provided, or thickness.</xs:documentation>
|
1014
1047
|
</xs:annotation>
|
1015
1048
|
</xs:element>
|
1049
|
+
<xs:element name="Flat-Ceiling-Insulation-Location-2" type="RoofInsulationLocationCode" minOccurs="0">
|
1050
|
+
<xs:annotation>
|
1051
|
+
<xs:documentation>Mutually exclusive with U-value and insulation type. Either U-value provided, or insulation type or location. To enable using table 16.</xs:documentation>
|
1052
|
+
</xs:annotation>
|
1053
|
+
</xs:element>
|
1016
1054
|
<xs:element name="Stud-Wall-Length-1" type="Measurement" minOccurs="0"/>
|
1017
1055
|
<xs:element name="Stud-Wall-Height-1" type="Measurement" minOccurs="0"/>
|
1018
1056
|
<xs:element name="Stud-Wall-U-Value-1" type="xs:decimal" minOccurs="0"/>
|
@@ -1068,9 +1106,19 @@ If the total peak power has been apportioned between different dwellings within
|
|
1068
1106
|
<xs:element name="Gable-Wall-Length-1" type="Measurement" minOccurs="0"/>
|
1069
1107
|
<xs:element name="Gable-Wall-Height-1" type="Measurement" minOccurs="0"/>
|
1070
1108
|
<xs:element name="Gable-Wall-U-Value-1" type="xs:decimal" minOccurs="0"/>
|
1109
|
+
<xs:element name="Gable-Wall-Type-1" type="GableType" minOccurs="0">
|
1110
|
+
<xs:annotation>
|
1111
|
+
<xs:documentation>Mutually exclusive with U-value. Either U-value provided, or gable type to use table 4.</xs:documentation>
|
1112
|
+
</xs:annotation>
|
1113
|
+
</xs:element>
|
1071
1114
|
<xs:element name="Gable-Wall-Length-2" type="Measurement" minOccurs="0"/>
|
1072
1115
|
<xs:element name="Gable-Wall-Height-2" type="Measurement" minOccurs="0"/>
|
1073
1116
|
<xs:element name="Gable-Wall-U-Value-2" type="xs:decimal" minOccurs="0"/>
|
1117
|
+
<xs:element name="Gable-Wall-Type-2" type="GableType" minOccurs="0">
|
1118
|
+
<xs:annotation>
|
1119
|
+
<xs:documentation>Mutually exclusive with U-value. Either U-value provided, or gable type to use table 4.</xs:documentation>
|
1120
|
+
</xs:annotation>
|
1121
|
+
</xs:element>
|
1074
1122
|
<xs:element name="Common-Wall-Length-1" type="Measurement" minOccurs="0"/>
|
1075
1123
|
<xs:element name="Common-Wall-Height-1" type="Measurement" minOccurs="0"/>
|
1076
1124
|
<xs:element name="Common-Wall-U-Value-1" type="xs:decimal" minOccurs="0"/>
|
@@ -461,6 +461,41 @@
|
|
461
461
|
<xs:documentation>Party wall insulation</xs:documentation>
|
462
462
|
</xs:annotation>
|
463
463
|
</xs:enumeration>
|
464
|
+
<xs:enumeration value="65">
|
465
|
+
<xs:annotation>
|
466
|
+
<xs:documentation>Internal insulation with cavity wall insulation</xs:documentation>
|
467
|
+
</xs:annotation>
|
468
|
+
</xs:enumeration>
|
469
|
+
<xs:enumeration value="66">
|
470
|
+
<xs:annotation>
|
471
|
+
<xs:documentation>Heating controls for wet central heating system</xs:documentation>
|
472
|
+
</xs:annotation>
|
473
|
+
</xs:enumeration>
|
474
|
+
<xs:enumeration value="70">
|
475
|
+
<xs:annotation>
|
476
|
+
<xs:documentation>Water Heating Controls</xs:documentation>
|
477
|
+
</xs:annotation>
|
478
|
+
</xs:enumeration>
|
479
|
+
<xs:enumeration value="72">
|
480
|
+
<xs:annotation>
|
481
|
+
<xs:documentation>PV Battery</xs:documentation>
|
482
|
+
</xs:annotation>
|
483
|
+
</xs:enumeration>
|
484
|
+
<xs:enumeration value="73">
|
485
|
+
<xs:annotation>
|
486
|
+
<xs:documentation>PV Diverter</xs:documentation>
|
487
|
+
</xs:annotation>
|
488
|
+
</xs:enumeration>
|
489
|
+
<xs:enumeration value="75">
|
490
|
+
<xs:annotation>
|
491
|
+
<xs:documentation>Ground source heat pump with radiators</xs:documentation>
|
492
|
+
</xs:annotation>
|
493
|
+
</xs:enumeration>
|
494
|
+
<xs:enumeration value="76">
|
495
|
+
<xs:annotation>
|
496
|
+
<xs:documentation>Ground source heat pump with underfloor heating</xs:documentation>
|
497
|
+
</xs:annotation>
|
498
|
+
</xs:enumeration>
|
464
499
|
</xs:restriction>
|
465
500
|
</xs:simpleType>
|
466
501
|
<xs:simpleType name="GreenDealCategoryCode">
|