epb_view_models 1.2.2 → 2.0.0

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (152) hide show
  1. checksums.yaml +4 -4
  2. data/Gemfile +1 -1
  3. data/Gemfile.lock +38 -28
  4. data/epb_view_models.gemspec +1 -1
  5. data/lib/epb_view_models.rb +1 -1
  6. data/lib/presenter/cepc/report.rb +11 -15
  7. data/lib/presenter/cepc/summary.rb +5 -14
  8. data/lib/presenter/dec/report.rb +5 -9
  9. data/lib/presenter/dec/summary.rb +3 -11
  10. data/lib/presenter/dec/xml_summary.rb +2 -2
  11. data/lib/presenter/export/base.rb +4 -4
  12. data/lib/presenter/export/commercial.rb +16 -27
  13. data/lib/presenter/export/domestic.rb +30 -39
  14. data/lib/presenter/rd_sap/domestic_digest.rb +2 -4
  15. data/lib/presenter/rd_sap/report.rb +47 -57
  16. data/lib/presenter/rd_sap/summary.rb +13 -21
  17. data/lib/presenter/sap/domestic_digest.rb +2 -4
  18. data/lib/presenter/sap/report.rb +49 -59
  19. data/lib/presenter/sap/summary.rb +28 -41
  20. data/lib/view_model/cepc31/cepc.rb +4 -44
  21. data/lib/view_model/cepc31/common_schema.rb +1 -1
  22. data/lib/view_model/cepc31/dec.rb +14 -34
  23. data/lib/view_model/cepc40/ac_report.rb +1 -1
  24. data/lib/view_model/cepc40/cepc.rb +6 -30
  25. data/lib/view_model/cepc40/common_schema.rb +1 -1
  26. data/lib/view_model/cepc40/dec.rb +16 -16
  27. data/lib/view_model/cepc50/ac_report.rb +1 -1
  28. data/lib/view_model/cepc50/cepc.rb +6 -10
  29. data/lib/view_model/cepc50/common_schema.rb +1 -1
  30. data/lib/view_model/cepc50/dec.rb +16 -16
  31. data/lib/view_model/cepc51/ac_report.rb +1 -1
  32. data/lib/view_model/cepc51/cepc.rb +6 -6
  33. data/lib/view_model/cepc51/common_schema.rb +1 -1
  34. data/lib/view_model/cepc51/dec.rb +16 -16
  35. data/lib/view_model/cepc60/ac_report.rb +1 -1
  36. data/lib/view_model/cepc60/cepc.rb +6 -10
  37. data/lib/view_model/cepc60/common_schema.rb +1 -1
  38. data/lib/view_model/cepc60/dec.rb +17 -17
  39. data/lib/view_model/cepc70/ac_cert.rb +3 -3
  40. data/lib/view_model/cepc70/ac_report.rb +1 -1
  41. data/lib/view_model/cepc70/cepc.rb +6 -10
  42. data/lib/view_model/cepc70/common_schema.rb +1 -1
  43. data/lib/view_model/cepc70/dec.rb +17 -17
  44. data/lib/view_model/cepc71/ac_cert.rb +3 -3
  45. data/lib/view_model/cepc71/ac_report.rb +1 -1
  46. data/lib/view_model/cepc71/cepc.rb +6 -6
  47. data/lib/view_model/cepc71/common_schema.rb +1 -1
  48. data/lib/view_model/cepc71/dec.rb +17 -17
  49. data/lib/view_model/cepc800/ac_cert.rb +3 -3
  50. data/lib/view_model/cepc800/ac_report.rb +1 -1
  51. data/lib/view_model/cepc800/cepc.rb +6 -11
  52. data/lib/view_model/cepc800/common_schema.rb +1 -1
  53. data/lib/view_model/cepc800/dec.rb +17 -17
  54. data/lib/view_model/cepc_ni800/ac_cert.rb +3 -3
  55. data/lib/view_model/cepc_ni800/ac_report.rb +1 -1
  56. data/lib/view_model/cepc_ni800/cepc.rb +6 -10
  57. data/lib/view_model/cepc_ni800/common_schema.rb +1 -1
  58. data/lib/view_model/cepc_ni800/dec.rb +17 -17
  59. data/lib/view_model/rd_sap_schema_170/common_schema.rb +17 -25
  60. data/lib/view_model/rd_sap_schema_171/common_schema.rb +17 -25
  61. data/lib/view_model/rd_sap_schema_180/common_schema.rb +17 -25
  62. data/lib/view_model/rd_sap_schema_190/common_schema.rb +17 -25
  63. data/lib/view_model/rd_sap_schema_200/common_schema.rb +17 -25
  64. data/lib/view_model/rd_sap_schema_210/common_schema.rb +14 -34
  65. data/lib/view_model/rd_sap_schema_ni_173/common_schema.rb +17 -25
  66. data/lib/view_model/rd_sap_schema_ni_174/common_schema.rb +17 -25
  67. data/lib/view_model/rd_sap_schema_ni_180/common_schema.rb +17 -25
  68. data/lib/view_model/rd_sap_schema_ni_190/common_schema.rb +17 -25
  69. data/lib/view_model/rd_sap_schema_ni_200/common_schema.rb +17 -25
  70. data/lib/view_model/sap_schema_102/common_schema.rb +13 -85
  71. data/lib/view_model/sap_schema_102/rdsap.rb +3 -3
  72. data/lib/view_model/sap_schema_110/common_schema.rb +13 -65
  73. data/lib/view_model/sap_schema_110/rdsap.rb +3 -19
  74. data/lib/view_model/sap_schema_110/sap.rb +1 -1
  75. data/lib/view_model/sap_schema_112/common_schema.rb +13 -65
  76. data/lib/view_model/sap_schema_112/rdsap.rb +3 -19
  77. data/lib/view_model/sap_schema_112/sap.rb +1 -1
  78. data/lib/view_model/sap_schema_120/common_schema.rb +13 -61
  79. data/lib/view_model/sap_schema_120/rdsap.rb +3 -19
  80. data/lib/view_model/sap_schema_120/sap.rb +1 -1
  81. data/lib/view_model/sap_schema_130/common_schema.rb +13 -61
  82. data/lib/view_model/sap_schema_130/rdsap.rb +3 -19
  83. data/lib/view_model/sap_schema_130/sap.rb +1 -1
  84. data/lib/view_model/sap_schema_140/common_schema.rb +14 -58
  85. data/lib/view_model/sap_schema_140/rdsap.rb +3 -19
  86. data/lib/view_model/sap_schema_140/sap.rb +1 -1
  87. data/lib/view_model/sap_schema_141/common_schema.rb +14 -58
  88. data/lib/view_model/sap_schema_141/rdsap.rb +3 -19
  89. data/lib/view_model/sap_schema_141/sap.rb +1 -1
  90. data/lib/view_model/sap_schema_142/common_schema.rb +14 -58
  91. data/lib/view_model/sap_schema_142/rdsap.rb +3 -19
  92. data/lib/view_model/sap_schema_142/sap.rb +1 -1
  93. data/lib/view_model/sap_schema_150/common_schema.rb +14 -58
  94. data/lib/view_model/sap_schema_150/rdsap.rb +3 -19
  95. data/lib/view_model/sap_schema_150/sap.rb +1 -1
  96. data/lib/view_model/sap_schema_160/common_schema.rb +14 -58
  97. data/lib/view_model/sap_schema_160/rdsap.rb +3 -19
  98. data/lib/view_model/sap_schema_160/sap.rb +1 -1
  99. data/lib/view_model/sap_schema_161/common_schema.rb +14 -58
  100. data/lib/view_model/sap_schema_161/rdsap.rb +3 -19
  101. data/lib/view_model/sap_schema_161/sap.rb +1 -1
  102. data/lib/view_model/sap_schema_162/common_schema.rb +14 -58
  103. data/lib/view_model/sap_schema_162/rdsap.rb +3 -19
  104. data/lib/view_model/sap_schema_162/sap.rb +1 -1
  105. data/lib/view_model/sap_schema_163/common_schema.rb +13 -53
  106. data/lib/view_model/sap_schema_163/rdsap.rb +3 -19
  107. data/lib/view_model/sap_schema_163/sap.rb +1 -1
  108. data/lib/view_model/sap_schema_170/common_schema.rb +13 -65
  109. data/lib/view_model/sap_schema_171/common_schema.rb +13 -65
  110. data/lib/view_model/sap_schema_1800/common_schema.rb +12 -64
  111. data/lib/view_model/sap_schema_1900/common_schema.rb +10 -50
  112. data/lib/view_model/sap_schema_1910/common_schema.rb +10 -50
  113. data/lib/view_model/sap_schema_ni_112/common_schema.rb +13 -61
  114. data/lib/view_model/sap_schema_ni_112/rdsap.rb +3 -19
  115. data/lib/view_model/sap_schema_ni_112/sap.rb +1 -1
  116. data/lib/view_model/sap_schema_ni_120/common_schema.rb +13 -61
  117. data/lib/view_model/sap_schema_ni_120/rdsap.rb +3 -19
  118. data/lib/view_model/sap_schema_ni_120/sap.rb +1 -1
  119. data/lib/view_model/sap_schema_ni_130/common_schema.rb +13 -61
  120. data/lib/view_model/sap_schema_ni_130/rdsap.rb +3 -19
  121. data/lib/view_model/sap_schema_ni_130/sap.rb +1 -1
  122. data/lib/view_model/sap_schema_ni_140/common_schema.rb +14 -58
  123. data/lib/view_model/sap_schema_ni_140/rdsap.rb +3 -19
  124. data/lib/view_model/sap_schema_ni_140/sap.rb +1 -1
  125. data/lib/view_model/sap_schema_ni_141/common_schema.rb +14 -58
  126. data/lib/view_model/sap_schema_ni_141/rdsap.rb +3 -19
  127. data/lib/view_model/sap_schema_ni_141/sap.rb +1 -1
  128. data/lib/view_model/sap_schema_ni_142/common_schema.rb +14 -58
  129. data/lib/view_model/sap_schema_ni_142/rdsap.rb +3 -19
  130. data/lib/view_model/sap_schema_ni_142/sap.rb +1 -1
  131. data/lib/view_model/sap_schema_ni_150/common_schema.rb +14 -58
  132. data/lib/view_model/sap_schema_ni_150/rdsap.rb +3 -19
  133. data/lib/view_model/sap_schema_ni_150/sap.rb +1 -1
  134. data/lib/view_model/sap_schema_ni_160/common_schema.rb +14 -54
  135. data/lib/view_model/sap_schema_ni_160/rdsap.rb +3 -19
  136. data/lib/view_model/sap_schema_ni_160/sap.rb +1 -1
  137. data/lib/view_model/sap_schema_ni_161/common_schema.rb +14 -50
  138. data/lib/view_model/sap_schema_ni_161/rdsap.rb +3 -19
  139. data/lib/view_model/sap_schema_ni_161/sap.rb +1 -1
  140. data/lib/view_model/sap_schema_ni_170/common_schema.rb +14 -54
  141. data/lib/view_model/sap_schema_ni_170/rdsap.rb +3 -19
  142. data/lib/view_model/sap_schema_ni_170/sap.rb +1 -1
  143. data/lib/view_model/sap_schema_ni_171/common_schema.rb +14 -54
  144. data/lib/view_model/sap_schema_ni_171/rdsap.rb +3 -19
  145. data/lib/view_model/sap_schema_ni_171/sap.rb +1 -1
  146. data/lib/view_model/sap_schema_ni_172/common_schema.rb +14 -54
  147. data/lib/view_model/sap_schema_ni_172/rdsap.rb +3 -23
  148. data/lib/view_model/sap_schema_ni_172/sap.rb +1 -1
  149. data/lib/view_model/sap_schema_ni_173/common_schema.rb +10 -78
  150. data/lib/view_model/sap_schema_ni_174/common_schema.rb +10 -78
  151. data/lib/view_model/sap_schema_ni_1800/common_schema.rb +10 -78
  152. metadata +4 -4
@@ -160,11 +160,11 @@ module ViewModel
160
160
  end
161
161
 
162
162
  def potential_energy_rating
163
- xpath(%w[Energy-Rating-Potential]).to_i
163
+ xpath(%w[Energy-Rating-Potential])&.to_i
164
164
  end
165
165
 
166
166
  def current_energy_rating
167
- xpath(%w[Energy-Rating-Current]).to_i
167
+ xpath(%w[Energy-Rating-Current])&.to_i
168
168
  end
169
169
 
170
170
  def estimated_energy_cost; end
@@ -201,40 +201,40 @@ module ViewModel
201
201
 
202
202
  def impact_of_cavity_insulation
203
203
  if xpath(%w[Impact-Of-Cavity-Insulation])
204
- xpath(%w[Impact-Of-Cavity-Insulation]).to_i
204
+ xpath(%w[Impact-Of-Cavity-Insulation])&.to_i
205
205
  end
206
206
  end
207
207
 
208
208
  def impact_of_loft_insulation
209
209
  if xpath(%w[Impact-Of-Loft-Insulation])
210
- xpath(%w[Impact-Of-Loft-Insulation]).to_i
210
+ xpath(%w[Impact-Of-Loft-Insulation])&.to_i
211
211
  end
212
212
  end
213
213
 
214
214
  def impact_of_solid_wall_insulation
215
215
  if xpath(%w[Impact-Of-Solid-Wall-Insulation])
216
- xpath(%w[Impact-Of-Solid-Wall-Insulation]).to_i
216
+ xpath(%w[Impact-Of-Solid-Wall-Insulation])&.to_i
217
217
  end
218
218
  end
219
219
 
220
220
  def habitable_room_count
221
- xpath(%w[Habitable-Room-Count])
221
+ xpath(%w[Habitable-Room-Count])&.to_i
222
222
  end
223
223
 
224
224
  def energy_rating_current
225
- xpath(%w[Energy-Rating-Current])
225
+ xpath(%w[Energy-Rating-Current])&.to_i
226
226
  end
227
227
 
228
228
  def energy_rating_potential
229
- xpath(%w[Energy-Rating-Potential])
229
+ xpath(%w[Energy-Rating-Potential])&.to_i
230
230
  end
231
231
 
232
232
  def environmental_impact_current
233
- xpath(%w[Environmental-Impact-Current])
233
+ xpath(%w[Environmental-Impact-Current])&.to_i
234
234
  end
235
235
 
236
236
  def environmental_impact_potential
237
- xpath(%w[Environmental-Impact-Potential])
237
+ xpath(%w[Environmental-Impact-Potential])&.to_i
238
238
  end
239
239
 
240
240
  def primary_energy_use
@@ -328,7 +328,7 @@ module ViewModel
328
328
  end
329
329
 
330
330
  def storey_count
331
- xpath(%w[Storey-Count])
331
+ xpath(%w[Storey-Count])&.to_i
332
332
  end
333
333
 
334
334
  def main_heating_controls
@@ -344,7 +344,7 @@ module ViewModel
344
344
  end
345
345
 
346
346
  def heated_room_count
347
- xpath(%w[Heated-Room-Count])
347
+ xpath(%w[Heated-Room-Count])&.to_i
348
348
  end
349
349
 
350
350
  def low_energy_lighting
@@ -352,15 +352,15 @@ module ViewModel
352
352
  end
353
353
 
354
354
  def fixed_lighting_outlets_count
355
- xpath(%w[Fixed-Lighting-Outlets-Count])
355
+ xpath(%w[Fixed-Lighting-Outlets-Count])&.to_i
356
356
  end
357
357
 
358
358
  def low_energy_fixed_lighting_outlets_count
359
- xpath(%w[Low-Energy-Fixed-Lighting-Outlets-Count])
359
+ xpath(%w[Low-Energy-Fixed-Lighting-Outlets-Count])&.to_i
360
360
  end
361
361
 
362
362
  def open_fireplaces_count
363
- xpath(%w[Open-Fireplaces-Count])
363
+ xpath(%w[Open-Fireplaces-Count])&.to_i
364
364
  end
365
365
 
366
366
  def hot_water_description
@@ -376,7 +376,7 @@ module ViewModel
376
376
  end
377
377
 
378
378
  def wind_turbine_count
379
- xpath(%w[Wind-Turbines-Count])
379
+ xpath(%w[Wind-Turbines-Count])&.to_i
380
380
  end
381
381
 
382
382
  def heat_loss_corridor
@@ -432,7 +432,7 @@ module ViewModel
432
432
  end
433
433
 
434
434
  def extensions_count
435
- xpath(%w[Extensions-Count])
435
+ xpath(%w[Extensions-Count])&.to_i
436
436
  end
437
437
 
438
438
  def report_type
@@ -528,14 +528,6 @@ module ViewModel
528
528
  def has_cylinder_thermostat
529
529
  xpath(%w[Cylinder-Thermostat])
530
530
  end
531
-
532
- def gas_smart_meter_present
533
- nil
534
- end
535
-
536
- def electricity_smart_meter_present
537
- nil
538
- end
539
531
  end
540
532
  end
541
533
  end
@@ -160,11 +160,11 @@ module ViewModel
160
160
  end
161
161
 
162
162
  def potential_energy_rating
163
- xpath(%w[Energy-Rating-Potential]).to_i
163
+ xpath(%w[Energy-Rating-Potential])&.to_i
164
164
  end
165
165
 
166
166
  def current_energy_rating
167
- xpath(%w[Energy-Rating-Current]).to_i
167
+ xpath(%w[Energy-Rating-Current])&.to_i
168
168
  end
169
169
 
170
170
  def estimated_energy_cost; end
@@ -201,40 +201,40 @@ module ViewModel
201
201
 
202
202
  def impact_of_cavity_insulation
203
203
  if xpath(%w[Impact-Of-Cavity-Insulation])
204
- xpath(%w[Impact-Of-Cavity-Insulation]).to_i
204
+ xpath(%w[Impact-Of-Cavity-Insulation])&.to_i
205
205
  end
206
206
  end
207
207
 
208
208
  def impact_of_loft_insulation
209
209
  if xpath(%w[Impact-Of-Loft-Insulation])
210
- xpath(%w[Impact-Of-Loft-Insulation]).to_i
210
+ xpath(%w[Impact-Of-Loft-Insulation])&.to_i
211
211
  end
212
212
  end
213
213
 
214
214
  def impact_of_solid_wall_insulation
215
215
  if xpath(%w[Impact-Of-Solid-Wall-Insulation])
216
- xpath(%w[Impact-Of-Solid-Wall-Insulation]).to_i
216
+ xpath(%w[Impact-Of-Solid-Wall-Insulation])&.to_i
217
217
  end
218
218
  end
219
219
 
220
220
  def habitable_room_count
221
- xpath(%w[Habitable-Room-Count])
221
+ xpath(%w[Habitable-Room-Count])&.to_i
222
222
  end
223
223
 
224
224
  def energy_rating_current
225
- xpath(%w[Energy-Rating-Current])
225
+ xpath(%w[Energy-Rating-Current])&.to_i
226
226
  end
227
227
 
228
228
  def energy_rating_potential
229
- xpath(%w[Energy-Rating-Potential])
229
+ xpath(%w[Energy-Rating-Potential])&.to_i
230
230
  end
231
231
 
232
232
  def environmental_impact_current
233
- xpath(%w[Environmental-Impact-Current])
233
+ xpath(%w[Environmental-Impact-Current])&.to_i
234
234
  end
235
235
 
236
236
  def environmental_impact_potential
237
- xpath(%w[Environmental-Impact-Potential])
237
+ xpath(%w[Environmental-Impact-Potential])&.to_i
238
238
  end
239
239
 
240
240
  def primary_energy_use
@@ -324,7 +324,7 @@ module ViewModel
324
324
  end
325
325
 
326
326
  def storey_count
327
- xpath(%w[Storey-Count])
327
+ xpath(%w[Storey-Count])&.to_i
328
328
  end
329
329
 
330
330
  def main_heating_controls
@@ -340,7 +340,7 @@ module ViewModel
340
340
  end
341
341
 
342
342
  def heated_room_count
343
- xpath(%w[Heated-Room-Count])
343
+ xpath(%w[Heated-Room-Count])&.to_i
344
344
  end
345
345
 
346
346
  def low_energy_lighting
@@ -348,15 +348,15 @@ module ViewModel
348
348
  end
349
349
 
350
350
  def fixed_lighting_outlets_count
351
- xpath(%w[Fixed-Lighting-Outlets-Count])
351
+ xpath(%w[Fixed-Lighting-Outlets-Count])&.to_i
352
352
  end
353
353
 
354
354
  def low_energy_fixed_lighting_outlets_count
355
- xpath(%w[Low-Energy-Fixed-Lighting-Outlets-Count])
355
+ xpath(%w[Low-Energy-Fixed-Lighting-Outlets-Count])&.to_i
356
356
  end
357
357
 
358
358
  def open_fireplaces_count
359
- xpath(%w[Open-Fireplaces-Count])
359
+ xpath(%w[Open-Fireplaces-Count])&.to_i
360
360
  end
361
361
 
362
362
  def hot_water_description
@@ -372,7 +372,7 @@ module ViewModel
372
372
  end
373
373
 
374
374
  def wind_turbine_count
375
- xpath(%w[Wind-Turbines-Count])
375
+ xpath(%w[Wind-Turbines-Count])&.to_i
376
376
  end
377
377
 
378
378
  def heat_loss_corridor
@@ -428,7 +428,7 @@ module ViewModel
428
428
  end
429
429
 
430
430
  def extensions_count
431
- xpath(%w[Extensions-Count])
431
+ xpath(%w[Extensions-Count])&.to_i
432
432
  end
433
433
 
434
434
  def report_type
@@ -528,14 +528,6 @@ module ViewModel
528
528
  def has_cylinder_thermostat
529
529
  xpath(%w[Cylinder-Thermostat])
530
530
  end
531
-
532
- def gas_smart_meter_present
533
- nil
534
- end
535
-
536
- def electricity_smart_meter_present
537
- nil
538
- end
539
531
  end
540
532
  end
541
533
  end
@@ -160,11 +160,11 @@ module ViewModel
160
160
  end
161
161
 
162
162
  def potential_energy_rating
163
- xpath(%w[Energy-Rating-Potential]).to_i
163
+ xpath(%w[Energy-Rating-Potential])&.to_i
164
164
  end
165
165
 
166
166
  def current_energy_rating
167
- xpath(%w[Energy-Rating-Current]).to_i
167
+ xpath(%w[Energy-Rating-Current])&.to_i
168
168
  end
169
169
 
170
170
  def estimated_energy_cost; end
@@ -201,40 +201,40 @@ module ViewModel
201
201
 
202
202
  def impact_of_cavity_insulation
203
203
  if xpath(%w[Impact-Of-Cavity-Insulation])
204
- xpath(%w[Impact-Of-Cavity-Insulation]).to_i
204
+ xpath(%w[Impact-Of-Cavity-Insulation])&.to_i
205
205
  end
206
206
  end
207
207
 
208
208
  def impact_of_loft_insulation
209
209
  if xpath(%w[Impact-Of-Loft-Insulation])
210
- xpath(%w[Impact-Of-Loft-Insulation]).to_i
210
+ xpath(%w[Impact-Of-Loft-Insulation])&.to_i
211
211
  end
212
212
  end
213
213
 
214
214
  def impact_of_solid_wall_insulation
215
215
  if xpath(%w[Impact-Of-Solid-Wall-Insulation])
216
- xpath(%w[Impact-Of-Solid-Wall-Insulation]).to_i
216
+ xpath(%w[Impact-Of-Solid-Wall-Insulation])&.to_i
217
217
  end
218
218
  end
219
219
 
220
220
  def habitable_room_count
221
- xpath(%w[Habitable-Room-Count])
221
+ xpath(%w[Habitable-Room-Count])&.to_i
222
222
  end
223
223
 
224
224
  def energy_rating_current
225
- xpath(%w[Energy-Rating-Current])
225
+ xpath(%w[Energy-Rating-Current])&.to_i
226
226
  end
227
227
 
228
228
  def energy_rating_potential
229
- xpath(%w[Energy-Rating-Potential])
229
+ xpath(%w[Energy-Rating-Potential])&.to_i
230
230
  end
231
231
 
232
232
  def environmental_impact_current
233
- xpath(%w[Environmental-Impact-Current])
233
+ xpath(%w[Environmental-Impact-Current])&.to_i
234
234
  end
235
235
 
236
236
  def environmental_impact_potential
237
- xpath(%w[Environmental-Impact-Potential])
237
+ xpath(%w[Environmental-Impact-Potential])&.to_i
238
238
  end
239
239
 
240
240
  def primary_energy_use
@@ -314,7 +314,7 @@ module ViewModel
314
314
  end
315
315
 
316
316
  def storey_count
317
- xpath(%w[Storey-Count])
317
+ xpath(%w[Storey-Count])&.to_i
318
318
  end
319
319
 
320
320
  def main_heating_controls
@@ -330,7 +330,7 @@ module ViewModel
330
330
  end
331
331
 
332
332
  def heated_room_count
333
- xpath(%w[Heated-Room-Count])
333
+ xpath(%w[Heated-Room-Count])&.to_i
334
334
  end
335
335
 
336
336
  def low_energy_lighting
@@ -338,15 +338,15 @@ module ViewModel
338
338
  end
339
339
 
340
340
  def fixed_lighting_outlets_count
341
- xpath(%w[Fixed-Lighting-Outlets-Count])
341
+ xpath(%w[Fixed-Lighting-Outlets-Count])&.to_i
342
342
  end
343
343
 
344
344
  def low_energy_fixed_lighting_outlets_count
345
- xpath(%w[Low-Energy-Fixed-Lighting-Outlets-Count])
345
+ xpath(%w[Low-Energy-Fixed-Lighting-Outlets-Count])&.to_i
346
346
  end
347
347
 
348
348
  def open_fireplaces_count
349
- xpath(%w[Open-Fireplaces-Count])
349
+ xpath(%w[Open-Fireplaces-Count])&.to_i
350
350
  end
351
351
 
352
352
  def hot_water_description
@@ -372,7 +372,7 @@ module ViewModel
372
372
  end
373
373
 
374
374
  def wind_turbine_count
375
- xpath(%w[Wind-Turbines-Count])
375
+ xpath(%w[Wind-Turbines-Count])&.to_i
376
376
  end
377
377
 
378
378
  def heat_loss_corridor
@@ -428,7 +428,7 @@ module ViewModel
428
428
  end
429
429
 
430
430
  def extensions_count
431
- xpath(%w[Extensions-Count])
431
+ xpath(%w[Extensions-Count])&.to_i
432
432
  end
433
433
 
434
434
  def report_type
@@ -528,14 +528,6 @@ module ViewModel
528
528
  def has_cylinder_thermostat
529
529
  xpath(%w[Cylinder-Thermostat])
530
530
  end
531
-
532
- def gas_smart_meter_present
533
- nil
534
- end
535
-
536
- def electricity_smart_meter_present
537
- nil
538
- end
539
531
  end
540
532
  end
541
533
  end
@@ -160,11 +160,11 @@ module ViewModel
160
160
  end
161
161
 
162
162
  def potential_energy_rating
163
- xpath(%w[Energy-Rating-Potential]).to_i
163
+ xpath(%w[Energy-Rating-Potential])&.to_i
164
164
  end
165
165
 
166
166
  def current_energy_rating
167
- xpath(%w[Energy-Rating-Current]).to_i
167
+ xpath(%w[Energy-Rating-Current])&.to_i
168
168
  end
169
169
 
170
170
  def estimated_energy_cost; end
@@ -201,40 +201,40 @@ module ViewModel
201
201
 
202
202
  def impact_of_cavity_insulation
203
203
  if xpath(%w[Impact-Of-Cavity-Insulation])
204
- xpath(%w[Impact-Of-Cavity-Insulation]).to_i
204
+ xpath(%w[Impact-Of-Cavity-Insulation])&.to_i
205
205
  end
206
206
  end
207
207
 
208
208
  def impact_of_loft_insulation
209
209
  if xpath(%w[Impact-Of-Loft-Insulation])
210
- xpath(%w[Impact-Of-Loft-Insulation]).to_i
210
+ xpath(%w[Impact-Of-Loft-Insulation])&.to_i
211
211
  end
212
212
  end
213
213
 
214
214
  def impact_of_solid_wall_insulation
215
215
  if xpath(%w[Impact-Of-Solid-Wall-Insulation])
216
- xpath(%w[Impact-Of-Solid-Wall-Insulation]).to_i
216
+ xpath(%w[Impact-Of-Solid-Wall-Insulation])&.to_i
217
217
  end
218
218
  end
219
219
 
220
220
  def habitable_room_count
221
- xpath(%w[Habitable-Room-Count])
221
+ xpath(%w[Habitable-Room-Count])&.to_i
222
222
  end
223
223
 
224
224
  def energy_rating_current
225
- xpath(%w[Energy-Rating-Current])
225
+ xpath(%w[Energy-Rating-Current])&.to_i
226
226
  end
227
227
 
228
228
  def energy_rating_potential
229
- xpath(%w[Energy-Rating-Potential])
229
+ xpath(%w[Energy-Rating-Potential])&.to_i
230
230
  end
231
231
 
232
232
  def environmental_impact_current
233
- xpath(%w[Environmental-Impact-Current])
233
+ xpath(%w[Environmental-Impact-Current])&.to_i
234
234
  end
235
235
 
236
236
  def environmental_impact_potential
237
- xpath(%w[Environmental-Impact-Potential])
237
+ xpath(%w[Environmental-Impact-Potential])&.to_i
238
238
  end
239
239
 
240
240
  def primary_energy_use
@@ -324,7 +324,7 @@ module ViewModel
324
324
  end
325
325
 
326
326
  def storey_count
327
- xpath(%w[Storey-Count])
327
+ xpath(%w[Storey-Count])&.to_i
328
328
  end
329
329
 
330
330
  def main_heating_controls
@@ -340,7 +340,7 @@ module ViewModel
340
340
  end
341
341
 
342
342
  def heated_room_count
343
- xpath(%w[Heated-Room-Count])
343
+ xpath(%w[Heated-Room-Count])&.to_i
344
344
  end
345
345
 
346
346
  def low_energy_lighting
@@ -348,15 +348,15 @@ module ViewModel
348
348
  end
349
349
 
350
350
  def fixed_lighting_outlets_count
351
- xpath(%w[Fixed-Lighting-Outlets-Count])
351
+ xpath(%w[Fixed-Lighting-Outlets-Count])&.to_i
352
352
  end
353
353
 
354
354
  def low_energy_fixed_lighting_outlets_count
355
- xpath(%w[Low-Energy-Fixed-Lighting-Outlets-Count])
355
+ xpath(%w[Low-Energy-Fixed-Lighting-Outlets-Count])&.to_i
356
356
  end
357
357
 
358
358
  def open_fireplaces_count
359
- xpath(%w[Open-Fireplaces-Count])
359
+ xpath(%w[Open-Fireplaces-Count])&.to_i
360
360
  end
361
361
 
362
362
  def hot_water_description
@@ -372,7 +372,7 @@ module ViewModel
372
372
  end
373
373
 
374
374
  def wind_turbine_count
375
- xpath(%w[Wind-Turbines-Count])
375
+ xpath(%w[Wind-Turbines-Count])&.to_i
376
376
  end
377
377
 
378
378
  def heat_loss_corridor
@@ -428,7 +428,7 @@ module ViewModel
428
428
  end
429
429
 
430
430
  def extensions_count
431
- xpath(%w[Extensions-Count])
431
+ xpath(%w[Extensions-Count])&.to_i
432
432
  end
433
433
 
434
434
  def report_type
@@ -528,14 +528,6 @@ module ViewModel
528
528
  def has_cylinder_thermostat
529
529
  xpath(%w[Cylinder-Thermostat])
530
530
  end
531
-
532
- def gas_smart_meter_present
533
- nil
534
- end
535
-
536
- def electricity_smart_meter_present
537
- nil
538
- end
539
531
  end
540
532
  end
541
533
  end
@@ -165,11 +165,11 @@ module ViewModel
165
165
  end
166
166
 
167
167
  def potential_energy_rating
168
- xpath(%w[Energy-Rating-Potential]).to_i
168
+ xpath(%w[Energy-Rating-Potential])&.to_i
169
169
  end
170
170
 
171
171
  def current_energy_rating
172
- xpath(%w[Energy-Rating-Current]).to_i
172
+ xpath(%w[Energy-Rating-Current])&.to_i
173
173
  end
174
174
 
175
175
  def estimated_energy_cost; end
@@ -206,40 +206,40 @@ module ViewModel
206
206
 
207
207
  def impact_of_cavity_insulation
208
208
  if xpath(%w[Impact-Of-Cavity-Insulation])
209
- xpath(%w[Impact-Of-Cavity-Insulation]).to_i
209
+ xpath(%w[Impact-Of-Cavity-Insulation])&.to_i
210
210
  end
211
211
  end
212
212
 
213
213
  def impact_of_loft_insulation
214
214
  if xpath(%w[Impact-Of-Loft-Insulation])
215
- xpath(%w[Impact-Of-Loft-Insulation]).to_i
215
+ xpath(%w[Impact-Of-Loft-Insulation])&.to_i
216
216
  end
217
217
  end
218
218
 
219
219
  def impact_of_solid_wall_insulation
220
220
  if xpath(%w[Impact-Of-Solid-Wall-Insulation])
221
- xpath(%w[Impact-Of-Solid-Wall-Insulation]).to_i
221
+ xpath(%w[Impact-Of-Solid-Wall-Insulation])&.to_i
222
222
  end
223
223
  end
224
224
 
225
225
  def habitable_room_count
226
- xpath(%w[Habitable-Room-Count])
226
+ xpath(%w[Habitable-Room-Count])&.to_i
227
227
  end
228
228
 
229
229
  def energy_rating_current
230
- xpath(%w[Energy-Rating-Current])
230
+ xpath(%w[Energy-Rating-Current])&.to_i
231
231
  end
232
232
 
233
233
  def energy_rating_potential
234
- xpath(%w[Energy-Rating-Potential])
234
+ xpath(%w[Energy-Rating-Potential])&.to_i
235
235
  end
236
236
 
237
237
  def environmental_impact_current
238
- xpath(%w[Environmental-Impact-Current])
238
+ xpath(%w[Environmental-Impact-Current])&.to_i
239
239
  end
240
240
 
241
241
  def environmental_impact_potential
242
- xpath(%w[Environmental-Impact-Potential])
242
+ xpath(%w[Environmental-Impact-Potential])&.to_i
243
243
  end
244
244
 
245
245
  def primary_energy_use
@@ -311,7 +311,7 @@ module ViewModel
311
311
  end
312
312
 
313
313
  def storey_count
314
- xpath(%w[Storey-Count])
314
+ xpath(%w[Storey-Count])&.to_i
315
315
  end
316
316
 
317
317
  def building_part_number
@@ -398,7 +398,7 @@ module ViewModel
398
398
  end
399
399
 
400
400
  def heated_room_count
401
- xpath(%w[Heated-Room-Count])
401
+ xpath(%w[Heated-Room-Count])&.to_i
402
402
  end
403
403
 
404
404
  def low_energy_lighting
@@ -406,15 +406,15 @@ module ViewModel
406
406
  end
407
407
 
408
408
  def fixed_lighting_outlets_count
409
- xpath(%w[Fixed-Lighting-Outlets-Count])
409
+ xpath(%w[Fixed-Lighting-Outlets-Count])&.to_i
410
410
  end
411
411
 
412
412
  def low_energy_fixed_lighting_outlets_count
413
- xpath(%w[Low-Energy-Fixed-Lighting-Outlets-Count])
413
+ xpath(%w[Low-Energy-Fixed-Lighting-Outlets-Count])&.to_i
414
414
  end
415
415
 
416
416
  def open_fireplaces_count
417
- xpath(%w[Open-Fireplaces-Count])
417
+ xpath(%w[Open-Fireplaces-Count])&.to_i
418
418
  end
419
419
 
420
420
  def hot_water_description
@@ -430,7 +430,7 @@ module ViewModel
430
430
  end
431
431
 
432
432
  def wind_turbine_count
433
- xpath(%w[Wind-Turbines-Count])
433
+ xpath(%w[Wind-Turbines-Count])&.to_i
434
434
  end
435
435
 
436
436
  def heat_loss_corridor
@@ -486,7 +486,7 @@ module ViewModel
486
486
  end
487
487
 
488
488
  def extensions_count
489
- xpath(%w[Extensions-Count])
489
+ xpath(%w[Extensions-Count])&.to_i
490
490
  end
491
491
 
492
492
  def report_type
@@ -582,14 +582,6 @@ module ViewModel
582
582
  def has_cylinder_thermostat
583
583
  xpath(%w[Cylinder-Thermostat])
584
584
  end
585
-
586
- def gas_smart_meter_present
587
- nil
588
- end
589
-
590
- def electricity_smart_meter_present
591
- nil
592
- end
593
585
  end
594
586
  end
595
587
  end