epb_view_models 1.0.4 → 1.0.8
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +4 -4
- data/lib/epb_view_models.rb +1 -1
- data/lib/helper/xml_enums_to_output.rb +82 -23
- data/lib/presenter/rd_sap/report.rb +2 -2
- data/lib/presenter/sap/report.rb +1 -1
- metadata +2 -2
checksums.yaml
CHANGED
@@ -1,7 +1,7 @@
|
|
1
1
|
---
|
2
2
|
SHA256:
|
3
|
-
metadata.gz:
|
4
|
-
data.tar.gz:
|
3
|
+
metadata.gz: 59d79d9f281a39f02dbee9c2951c691175b3dfc89f0bf3e3f907aa3210e07e8a
|
4
|
+
data.tar.gz: 648c87f4d9ad0b4f23eaf859969665ec413b4a62fd7fc621d764cd2211231eb2
|
5
5
|
SHA512:
|
6
|
-
metadata.gz:
|
7
|
-
data.tar.gz:
|
6
|
+
metadata.gz: 40c679fd072c9fea3087edcfc7e04d289f1bf4c653c60cb2f1c25fb114aa3cbf9d4ef1d4a3ac9c17220bd6b3f876d133b29e8d58bda62acf642e6fa16eef9977
|
7
|
+
data.tar.gz: a754bf7fe7e9a8fb144ae351fa1e7af1591ee572370d384a23fb857f254133c5087a313951dd77757dea1b38baaffb45c973de651a971a0f2bb941f1027ac4c3
|
data/lib/epb_view_models.rb
CHANGED
@@ -97,6 +97,34 @@ module Helper
|
|
97
97
|
"0" => "Not applicable",
|
98
98
|
"NR" => "Not recorded",
|
99
99
|
}.freeze
|
100
|
+
CONSTRUCTION_AGE_BAND_NI = {
|
101
|
+
"A" => "Northern Ireland: before 1919",
|
102
|
+
"A-12.0" => "Pre-1900",
|
103
|
+
"B" => "Northern Ireland: 1919-1929",
|
104
|
+
"B-12.0" => "1900-1929",
|
105
|
+
"C" => "Northern Ireland: 1930-1949",
|
106
|
+
"C-12.0" => "1930-1949",
|
107
|
+
"D" => "Northern Ireland: 1950-1973",
|
108
|
+
"D-12.0" => "1950-1966",
|
109
|
+
"E" => "Northern Ireland: 1974-1977",
|
110
|
+
"E-12.0" => "1967-1975",
|
111
|
+
"F" => "Northern Ireland: 1978-1985",
|
112
|
+
"F-12.0" => "1976-1982",
|
113
|
+
"G" => "Northern Ireland: 1986-1991",
|
114
|
+
"G-12.0" => "1983-1990",
|
115
|
+
"H" => "Northern Ireland: 1992-1999",
|
116
|
+
"H-12.0" => "1991-1995",
|
117
|
+
"I" => "Northern Ireland: 2000-2006",
|
118
|
+
"I-12.0" => "1996-2002",
|
119
|
+
"J" => "Northern Ireland: not applicable",
|
120
|
+
"J-12.0" => "2003-2006",
|
121
|
+
"K-RdSAP-NI" => "Northern Ireland: 2007-2013",
|
122
|
+
"K-SAP-NI" => "Northern Ireland: 2007 onwards",
|
123
|
+
"K-12.0" => "Post-2006",
|
124
|
+
"L" => "Northern Ireland: 2014 onwards",
|
125
|
+
"0" => "Not applicable",
|
126
|
+
"NR" => "Not recorded",
|
127
|
+
}.freeze
|
100
128
|
PROPERTY_TYPE = {
|
101
129
|
"0" => "House",
|
102
130
|
"1" => "Bungalow",
|
@@ -135,7 +163,7 @@ module Helper
|
|
135
163
|
"6" => "mechanical extract, decentralised (MEV dc)",
|
136
164
|
"7" => "balanced without heat recovery (MV)",
|
137
165
|
"8" => "balanced with heat recovery (MVHR)",
|
138
|
-
"9" => "natural with intermittent extract fans and/or passive vents.
|
166
|
+
"9" => "natural with intermittent extract fans and/or passive vents. For backwards compatibility only, do not use.",
|
139
167
|
"10" => "natural with intermittent extract fans and passive vents",
|
140
168
|
}.freeze
|
141
169
|
CYLINDER_INSULATION_THICKNESS = {
|
@@ -278,7 +306,7 @@ module Helper
|
|
278
306
|
end
|
279
307
|
|
280
308
|
def self.transaction_type(value, report_type = "2", schema_type = "")
|
281
|
-
types_of_ni = %
|
309
|
+
types_of_ni = %i[
|
282
310
|
RdSAP-Schema-NI-20.0.0
|
283
311
|
RdSAP-Schema-NI-19.0
|
284
312
|
RdSAP-Schema-NI-18.0
|
@@ -303,7 +331,7 @@ module Helper
|
|
303
331
|
end
|
304
332
|
|
305
333
|
def self.construction_age_band_lookup(value, schema_type, report_type)
|
306
|
-
types_of_sap_pre17 = %
|
334
|
+
types_of_sap_pre17 = %i[
|
307
335
|
SAP-Schema-16.3
|
308
336
|
SAP-Schema-16.2
|
309
337
|
SAP-Schema-16.1
|
@@ -318,7 +346,7 @@ module Helper
|
|
318
346
|
SAP-Schema-11.0
|
319
347
|
].freeze
|
320
348
|
|
321
|
-
schemes_that_use_not_recorded = %
|
349
|
+
schemes_that_use_not_recorded = %i[
|
322
350
|
SAP-Schema-16.3
|
323
351
|
SAP-Schema-16.2
|
324
352
|
SAP-Schema-16.1
|
@@ -327,14 +355,9 @@ module Helper
|
|
327
355
|
RdSAP-Schema-18.0
|
328
356
|
RdSAP-Schema-17.1
|
329
357
|
RdSAP-Schema-17.0
|
330
|
-
RdSAP-Schema-NI-20.0.0
|
331
|
-
RdSAP-Schema-NI-19.0
|
332
|
-
RdSAP-Schema-NI-18.0
|
333
|
-
RdSAP-Schema-NI-17.4
|
334
|
-
RdSAP-Schema-NI-17.3
|
335
358
|
]
|
336
359
|
|
337
|
-
schemes_that_use_l = %
|
360
|
+
schemes_that_use_l = %i[
|
338
361
|
SAP-Schema-18.0.0
|
339
362
|
SAP-Schema-17.1
|
340
363
|
SAP-Schema-17.0
|
@@ -343,14 +366,9 @@ module Helper
|
|
343
366
|
RdSAP-Schema-18.0
|
344
367
|
RdSAP-Schema-17.1
|
345
368
|
RdSAP-Schema-17.0
|
346
|
-
RdSAP-Schema-NI-20.0.0
|
347
|
-
RdSAP-Schema-NI-19.0
|
348
|
-
RdSAP-Schema-NI-18.0
|
349
|
-
RdSAP-Schema-NI-17.4
|
350
|
-
RdSAP-Schema-NI-17.3
|
351
369
|
]
|
352
370
|
|
353
|
-
schemes_that_use_0 = %
|
371
|
+
schemes_that_use_0 = %i[
|
354
372
|
SAP-Schema-16.3
|
355
373
|
SAP-Schema-16.2
|
356
374
|
SAP-Schema-16.1
|
@@ -366,6 +384,25 @@ module Helper
|
|
366
384
|
RdSAP-Schema-18.0
|
367
385
|
RdSAP-Schema-17.1
|
368
386
|
RdSAP-Schema-17.0
|
387
|
+
]
|
388
|
+
|
389
|
+
sap_schemas_ni = %i[
|
390
|
+
SAP-Schema-NI-18.0.0
|
391
|
+
SAP-Schema-NI-17.4
|
392
|
+
SAP-Schema-NI-17.3
|
393
|
+
SAP-Schema-NI-17.2
|
394
|
+
SAP-Schema-NI-17.1
|
395
|
+
SAP-Schema-NI-17.0
|
396
|
+
SAP-Schema-NI-16.1
|
397
|
+
SAP-Schema-NI-16.0
|
398
|
+
SAP-Schema-NI-15.0
|
399
|
+
SAP-Schema-NI-14.2
|
400
|
+
SAP-Schema-NI-14.1
|
401
|
+
SAP-Schema-NI-14.0
|
402
|
+
SAP-Schema-NI-13.0
|
403
|
+
]
|
404
|
+
|
405
|
+
rdsap_schemas_ni = %i[
|
369
406
|
RdSAP-Schema-NI-20.0.0
|
370
407
|
RdSAP-Schema-NI-19.0
|
371
408
|
RdSAP-Schema-NI-18.0
|
@@ -373,7 +410,29 @@ module Helper
|
|
373
410
|
RdSAP-Schema-NI-17.3
|
374
411
|
]
|
375
412
|
|
376
|
-
|
413
|
+
ni_schemas_pre_12 = %i[
|
414
|
+
SAP-Schema-NI-12.0
|
415
|
+
SAP-Schema-NI-11.2
|
416
|
+
]
|
417
|
+
|
418
|
+
if value == "K" && rdsap_schemas_ni.include?(schema_type)
|
419
|
+
return CONSTRUCTION_AGE_BAND_NI["K-RdSAP-NI"] || value
|
420
|
+
end
|
421
|
+
|
422
|
+
if value == "K" && sap_schemas_ni.include?(schema_type)
|
423
|
+
return CONSTRUCTION_AGE_BAND_NI["K-SAP-NI"] || value
|
424
|
+
end
|
425
|
+
|
426
|
+
if ni_schemas_pre_12.include?(schema_type)
|
427
|
+
key = (value == "0" ? value : "#{value}-12.0")
|
428
|
+
return CONSTRUCTION_AGE_BAND_NI[key] || value
|
429
|
+
end
|
430
|
+
|
431
|
+
if sap_schemas_ni.include?(schema_type) || rdsap_schemas_ni.include?(schema_type)
|
432
|
+
return CONSTRUCTION_AGE_BAND_NI[value] || value
|
433
|
+
end
|
434
|
+
|
435
|
+
if value == "K" && schema_type == :"SAP-Schema-12.0" && is_rdsap(report_type)
|
377
436
|
return CONSTRUCTION_AGE_BAND["K-12.0"]
|
378
437
|
end
|
379
438
|
|
@@ -405,14 +464,13 @@ module Helper
|
|
405
464
|
end
|
406
465
|
|
407
466
|
def self.mechanical_ventilation(value, schema_type, report_type)
|
408
|
-
types_of_sap_pre12 = %
|
467
|
+
types_of_sap_pre12 = %i[
|
409
468
|
SAP-Schema-11.2
|
410
469
|
SAP-Schema-11.0
|
411
470
|
SAP-Schema-10.2
|
412
471
|
SAP-Schema-NI-11.2
|
413
472
|
].freeze
|
414
|
-
|
415
|
-
if types_of_sap_pre12.include?(schema_type.to_s) && is_rdsap(report_type)
|
473
|
+
if types_of_sap_pre12.include?(schema_type) && is_rdsap(report_type)
|
416
474
|
return MECHANICAL_VENTILATION["#{value}-pre12.0"]
|
417
475
|
end
|
418
476
|
|
@@ -440,7 +498,7 @@ module Helper
|
|
440
498
|
end
|
441
499
|
|
442
500
|
def self.ventilation_type(value, schema_type = "")
|
443
|
-
ni_sap = %
|
501
|
+
ni_sap = %i[
|
444
502
|
SAP-Schema-NI-16.1
|
445
503
|
SAP-Schema-NI-16.0
|
446
504
|
SAP-Schema-NI-15.0
|
@@ -539,13 +597,14 @@ module Helper
|
|
539
597
|
if rdsap.include?(schema_type)
|
540
598
|
RDSAP_FUEL_TYPE[value]
|
541
599
|
elsif sap.include?(schema_type) && is_sap(report_type)
|
542
|
-
|
600
|
+
SAP_FUEL_TYPE[value]
|
543
601
|
elsif sap.include?(schema_type) && is_rdsap(report_type)
|
544
602
|
if includes_rapeseed_oil.include?(schema_type) && value == "36"
|
545
603
|
return RDSAP_FUEL_TYPE["#{value}-rapeseed-oil"]
|
546
604
|
end
|
605
|
+
|
547
606
|
if pre143_sap.include?(schema_type)
|
548
|
-
|
607
|
+
RDSAP_FUEL_TYPE_PRE_143["#{value}-pre14.3-sap"] || RDSAP_FUEL_TYPE[value]
|
549
608
|
else
|
550
609
|
RDSAP_FUEL_TYPE[value]
|
551
610
|
end
|
@@ -31,7 +31,7 @@ module Presenter
|
|
31
31
|
co2_emissions_potential: @view_model.potential_carbon_emission,
|
32
32
|
construction_age_band:
|
33
33
|
Helper::XmlEnumsToOutput.construction_age_band_lookup(
|
34
|
-
@view_model.
|
34
|
+
@view_model.main_dwelling_construction_age_band_or_year,
|
35
35
|
@schema_type,
|
36
36
|
@view_model.report_type,
|
37
37
|
),
|
@@ -40,7 +40,7 @@ module Presenter
|
|
40
40
|
Helper::EnergyBandCalculator.domestic(
|
41
41
|
@view_model.current_energy_rating,
|
42
42
|
),
|
43
|
-
cylinder_insul_thickness:
|
43
|
+
cylinder_insul_thickness: @view_model.cylinder_insul_thickness,
|
44
44
|
cylinder_insulation_type: @view_model.cylinder_insulation_type,
|
45
45
|
cylinder_size: @view_model.cylinder_size,
|
46
46
|
has_cylinder_thermostat: @view_model.has_cylinder_thermostat == "Y" ? "true" : "false",
|
data/lib/presenter/sap/report.rb
CHANGED
@@ -40,7 +40,7 @@ module Presenter
|
|
40
40
|
Helper::EnergyBandCalculator.domestic(
|
41
41
|
@view_model.current_energy_rating,
|
42
42
|
),
|
43
|
-
cylinder_insul_thickness:
|
43
|
+
cylinder_insul_thickness: @view_model.cylinder_insul_thickness,
|
44
44
|
cylinder_insulation_type: @view_model.cylinder_insulation_type,
|
45
45
|
cylinder_size: @view_model.cylinder_size,
|
46
46
|
has_cylinder_thermostat: @view_model.has_cylinder_thermostat,
|
metadata
CHANGED
@@ -1,14 +1,14 @@
|
|
1
1
|
--- !ruby/object:Gem::Specification
|
2
2
|
name: epb_view_models
|
3
3
|
version: !ruby/object:Gem::Version
|
4
|
-
version: 1.0.
|
4
|
+
version: 1.0.8
|
5
5
|
platform: ruby
|
6
6
|
authors:
|
7
7
|
- MHCLG Energy Performance of Buildings
|
8
8
|
autorequire:
|
9
9
|
bindir: exe
|
10
10
|
cert_chain: []
|
11
|
-
date: 2021-09-
|
11
|
+
date: 2021-09-27 00:00:00.000000000 Z
|
12
12
|
dependencies:
|
13
13
|
- !ruby/object:Gem::Dependency
|
14
14
|
name: nokogiri
|