epb_view_models 1.0.2 → 1.0.3
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +4 -4
- data/.DS_Store +0 -0
- data/.buildspec.yml +13 -0
- data/.gitignore +5 -0
- data/.ruby-version +1 -0
- data/Gemfile.lock +22 -17
- data/lib/epb_view_models.rb +1 -1
- data/lib/helper/xml_enums_to_output.rb +23 -13
- data/lib/presenter/rd_sap/report.rb +196 -1
- data/lib/presenter/sap/report.rb +194 -0
- data/lib/view_model/rd_sap_schema_170/common_schema.rb +16 -0
- data/lib/view_model/rd_sap_schema_171/common_schema.rb +16 -0
- data/lib/view_model/rd_sap_schema_180/common_schema.rb +16 -0
- data/lib/view_model/rd_sap_schema_190/common_schema.rb +16 -0
- data/lib/view_model/rd_sap_schema_200/common_schema.rb +16 -0
- data/lib/view_model/rd_sap_schema_ni_173/common_schema.rb +16 -0
- data/lib/view_model/rd_sap_schema_ni_174/common_schema.rb +16 -0
- data/lib/view_model/rd_sap_schema_ni_180/common_schema.rb +16 -0
- data/lib/view_model/rd_sap_schema_ni_190/common_schema.rb +16 -0
- data/lib/view_model/rd_sap_schema_ni_200/common_schema.rb +16 -0
- data/lib/view_model/rd_sap_wrapper.rb +4 -0
- data/lib/view_model/sap_schema_102/common_schema.rb +28 -0
- data/lib/view_model/sap_schema_102/rdsap.rb +4 -0
- data/lib/view_model/sap_schema_110/common_schema.rb +1 -2
- data/lib/view_model/sap_schema_110/rdsap.rb +28 -0
- data/lib/view_model/sap_schema_110/sap.rb +28 -0
- data/lib/view_model/sap_schema_112/common_schema.rb +1 -2
- data/lib/view_model/sap_schema_112/rdsap.rb +28 -0
- data/lib/view_model/sap_schema_112/sap.rb +28 -0
- data/lib/view_model/sap_schema_120/rdsap.rb +28 -0
- data/lib/view_model/sap_schema_120/sap.rb +28 -0
- data/lib/view_model/sap_schema_130/rdsap.rb +28 -0
- data/lib/view_model/sap_schema_130/sap.rb +28 -0
- data/lib/view_model/sap_schema_140/rdsap.rb +28 -0
- data/lib/view_model/sap_schema_140/sap.rb +28 -0
- data/lib/view_model/sap_schema_141/rdsap.rb +28 -0
- data/lib/view_model/sap_schema_141/sap.rb +28 -0
- data/lib/view_model/sap_schema_142/rdsap.rb +28 -0
- data/lib/view_model/sap_schema_142/sap.rb +28 -0
- data/lib/view_model/sap_schema_150/rdsap.rb +28 -0
- data/lib/view_model/sap_schema_150/sap.rb +28 -0
- data/lib/view_model/sap_schema_160/rdsap.rb +28 -0
- data/lib/view_model/sap_schema_160/sap.rb +28 -0
- data/lib/view_model/sap_schema_161/rdsap.rb +28 -0
- data/lib/view_model/sap_schema_161/sap.rb +28 -0
- data/lib/view_model/sap_schema_162/rdsap.rb +28 -0
- data/lib/view_model/sap_schema_162/sap.rb +28 -0
- data/lib/view_model/sap_schema_163/rdsap.rb +28 -0
- data/lib/view_model/sap_schema_163/sap.rb +28 -0
- data/lib/view_model/sap_schema_170/common_schema.rb +28 -0
- data/lib/view_model/sap_schema_171/common_schema.rb +28 -0
- data/lib/view_model/sap_schema_1800/common_schema.rb +28 -0
- data/lib/view_model/sap_schema_ni_112/rdsap.rb +32 -4
- data/lib/view_model/sap_schema_ni_112/sap.rb +27 -0
- data/lib/view_model/sap_schema_ni_120/rdsap.rb +32 -0
- data/lib/view_model/sap_schema_ni_120/sap.rb +28 -0
- data/lib/view_model/sap_schema_ni_130/rdsap.rb +32 -0
- data/lib/view_model/sap_schema_ni_130/sap.rb +28 -0
- data/lib/view_model/sap_schema_ni_140/rdsap.rb +32 -0
- data/lib/view_model/sap_schema_ni_140/sap.rb +28 -0
- data/lib/view_model/sap_schema_ni_141/rdsap.rb +32 -0
- data/lib/view_model/sap_schema_ni_141/sap.rb +28 -0
- data/lib/view_model/sap_schema_ni_142/rdsap.rb +32 -0
- data/lib/view_model/sap_schema_ni_142/sap.rb +28 -0
- data/lib/view_model/sap_schema_ni_150/rdsap.rb +32 -0
- data/lib/view_model/sap_schema_ni_150/sap.rb +28 -0
- data/lib/view_model/sap_schema_ni_160/common_schema.rb +2 -2
- data/lib/view_model/sap_schema_ni_160/rdsap.rb +28 -0
- data/lib/view_model/sap_schema_ni_160/sap.rb +28 -0
- data/lib/view_model/sap_schema_ni_161/common_schema.rb +1 -1
- data/lib/view_model/sap_schema_ni_161/rdsap.rb +28 -0
- data/lib/view_model/sap_schema_ni_161/sap.rb +28 -0
- data/lib/view_model/sap_schema_ni_170/rdsap.rb +28 -0
- data/lib/view_model/sap_schema_ni_170/sap.rb +28 -0
- data/lib/view_model/sap_schema_ni_171/rdsap.rb +28 -0
- data/lib/view_model/sap_schema_ni_171/sap.rb +28 -0
- data/lib/view_model/sap_schema_ni_172/rdsap.rb +36 -0
- data/lib/view_model/sap_schema_ni_172/sap.rb +28 -0
- data/lib/view_model/sap_schema_ni_173/common_schema.rb +28 -0
- data/lib/view_model/sap_schema_ni_174/common_schema.rb +28 -0
- data/lib/view_model/sap_schema_ni_1800/common_schema.rb +28 -0
- data/lib/view_model/sap_wrapper.rb +4 -0
- metadata +5 -2
@@ -8,6 +8,34 @@ module ViewModel
|
|
8
8
|
def construction_year
|
9
9
|
xpath(%w[Construction-Year])
|
10
10
|
end
|
11
|
+
|
12
|
+
def cylinder_insul_thickness
|
13
|
+
xpath(%w[Hot-Water-Store-Insulation-Thickness])
|
14
|
+
end
|
15
|
+
|
16
|
+
def cylinder_insulation_type
|
17
|
+
xpath(%w[Hot-Water-Store-Insulation-Type])
|
18
|
+
end
|
19
|
+
|
20
|
+
def cylinder_size
|
21
|
+
xpath(%w[Hot-Water-Store-Size])
|
22
|
+
end
|
23
|
+
|
24
|
+
def has_cylinder_thermostat
|
25
|
+
xpath(%w[Has-Cylinder-Thermostat])
|
26
|
+
end
|
27
|
+
|
28
|
+
def mech_vent_sys_index_number
|
29
|
+
xpath(%w[Mechanical-Vent-System-Index-Number])
|
30
|
+
end
|
31
|
+
|
32
|
+
def mechanical_vent_data_source
|
33
|
+
xpath(%w[Mechanical-Ventilation-Data-Source])
|
34
|
+
end
|
35
|
+
|
36
|
+
def thermal_store
|
37
|
+
xpath(%w[Thermal-Store])
|
38
|
+
end
|
11
39
|
end
|
12
40
|
end
|
13
41
|
end
|
@@ -64,6 +64,34 @@ module ViewModel
|
|
64
64
|
def energy_tariff
|
65
65
|
xpath(%w[Meter-Type])
|
66
66
|
end
|
67
|
+
|
68
|
+
def cylinder_insul_thickness
|
69
|
+
xpath(%w[Cylinder-Insulation-Thickness])
|
70
|
+
end
|
71
|
+
|
72
|
+
def cylinder_insulation_type
|
73
|
+
xpath(%w[Cylinder-Insulation-Type])
|
74
|
+
end
|
75
|
+
|
76
|
+
def cylinder_size
|
77
|
+
xpath(%w[Cylinder-Size])
|
78
|
+
end
|
79
|
+
|
80
|
+
def has_cylinder_thermostat
|
81
|
+
xpath(%w[Cylinder-Thermostat])
|
82
|
+
end
|
83
|
+
|
84
|
+
def mech_vent_sys_index_number
|
85
|
+
nil
|
86
|
+
end
|
87
|
+
|
88
|
+
def mechanical_vent_data_source
|
89
|
+
nil
|
90
|
+
end
|
91
|
+
|
92
|
+
def thermal_store
|
93
|
+
nil
|
94
|
+
end
|
67
95
|
end
|
68
96
|
end
|
69
97
|
end
|
@@ -8,6 +8,34 @@ module ViewModel
|
|
8
8
|
def construction_year
|
9
9
|
xpath(%w[Construction-Year])
|
10
10
|
end
|
11
|
+
|
12
|
+
def cylinder_insul_thickness
|
13
|
+
xpath(%w[Hot-Water-Store-Insulation-Thickness])
|
14
|
+
end
|
15
|
+
|
16
|
+
def cylinder_insulation_type
|
17
|
+
xpath(%w[Hot-Water-Store-Insulation-Type])
|
18
|
+
end
|
19
|
+
|
20
|
+
def cylinder_size
|
21
|
+
xpath(%w[Hot-Water-Store-Size])
|
22
|
+
end
|
23
|
+
|
24
|
+
def has_cylinder_thermostat
|
25
|
+
xpath(%w[Has-Cylinder-Thermostat])
|
26
|
+
end
|
27
|
+
|
28
|
+
def mech_vent_sys_index_number
|
29
|
+
xpath(%w[Mechanical-Vent-System-Index-Number])
|
30
|
+
end
|
31
|
+
|
32
|
+
def mechanical_vent_data_source
|
33
|
+
xpath(%w[Mechanical-Ventilation-Data-Source])
|
34
|
+
end
|
35
|
+
|
36
|
+
def thermal_store
|
37
|
+
xpath(%w[Thermal-Store])
|
38
|
+
end
|
11
39
|
end
|
12
40
|
end
|
13
41
|
end
|
@@ -64,6 +64,34 @@ module ViewModel
|
|
64
64
|
def energy_tariff
|
65
65
|
xpath(%w[Meter-Type])
|
66
66
|
end
|
67
|
+
|
68
|
+
def cylinder_insul_thickness
|
69
|
+
xpath(%w[Cylinder-Insulation-Thickness])
|
70
|
+
end
|
71
|
+
|
72
|
+
def cylinder_insulation_type
|
73
|
+
xpath(%w[Cylinder-Insulation-Type])
|
74
|
+
end
|
75
|
+
|
76
|
+
def cylinder_size
|
77
|
+
xpath(%w[Cylinder-Size])
|
78
|
+
end
|
79
|
+
|
80
|
+
def has_cylinder_thermostat
|
81
|
+
xpath(%w[Cylinder-Thermostat])
|
82
|
+
end
|
83
|
+
|
84
|
+
def mech_vent_sys_index_number
|
85
|
+
nil
|
86
|
+
end
|
87
|
+
|
88
|
+
def mechanical_vent_data_source
|
89
|
+
nil
|
90
|
+
end
|
91
|
+
|
92
|
+
def thermal_store
|
93
|
+
nil
|
94
|
+
end
|
67
95
|
end
|
68
96
|
end
|
69
97
|
end
|
@@ -8,6 +8,34 @@ module ViewModel
|
|
8
8
|
def construction_year
|
9
9
|
xpath(%w[Construction-Year])
|
10
10
|
end
|
11
|
+
|
12
|
+
def cylinder_insul_thickness
|
13
|
+
xpath(%w[Hot-Water-Store-Insulation-Thickness])
|
14
|
+
end
|
15
|
+
|
16
|
+
def cylinder_insulation_type
|
17
|
+
xpath(%w[Hot-Water-Store-Insulation-Type])
|
18
|
+
end
|
19
|
+
|
20
|
+
def cylinder_size
|
21
|
+
xpath(%w[Hot-Water-Store-Size])
|
22
|
+
end
|
23
|
+
|
24
|
+
def has_cylinder_thermostat
|
25
|
+
xpath(%w[Has-Cylinder-Thermostat])
|
26
|
+
end
|
27
|
+
|
28
|
+
def mech_vent_sys_index_number
|
29
|
+
xpath(%w[Mechanical-Vent-System-Index-Number])
|
30
|
+
end
|
31
|
+
|
32
|
+
def mechanical_vent_data_source
|
33
|
+
xpath(%w[Mechanical-Ventilation-Data-Source])
|
34
|
+
end
|
35
|
+
|
36
|
+
def thermal_store
|
37
|
+
xpath(%w[Thermal-Store])
|
38
|
+
end
|
11
39
|
end
|
12
40
|
end
|
13
41
|
end
|
@@ -68,6 +68,34 @@ module ViewModel
|
|
68
68
|
def energy_tariff
|
69
69
|
xpath(%w[Meter-Type])
|
70
70
|
end
|
71
|
+
|
72
|
+
def cylinder_insul_thickness
|
73
|
+
xpath(%w[Cylinder-Insulation-Thickness])
|
74
|
+
end
|
75
|
+
|
76
|
+
def cylinder_insulation_type
|
77
|
+
xpath(%w[Cylinder-Insulation-Type])
|
78
|
+
end
|
79
|
+
|
80
|
+
def cylinder_size
|
81
|
+
xpath(%w[Cylinder-Size])
|
82
|
+
end
|
83
|
+
|
84
|
+
def has_cylinder_thermostat
|
85
|
+
xpath(%w[Cylinder-Thermostat])
|
86
|
+
end
|
87
|
+
|
88
|
+
def mech_vent_sys_index_number
|
89
|
+
nil
|
90
|
+
end
|
91
|
+
|
92
|
+
def mechanical_vent_data_source
|
93
|
+
nil
|
94
|
+
end
|
95
|
+
|
96
|
+
def thermal_store
|
97
|
+
nil
|
98
|
+
end
|
71
99
|
end
|
72
100
|
end
|
73
101
|
end
|
@@ -17,6 +17,34 @@ module ViewModel
|
|
17
17
|
def construction_year
|
18
18
|
xpath(%w[Construction-Year])
|
19
19
|
end
|
20
|
+
|
21
|
+
def cylinder_insul_thickness
|
22
|
+
xpath(%w[Hot-Water-Store-Insulation-Thickness])
|
23
|
+
end
|
24
|
+
|
25
|
+
def cylinder_insulation_type
|
26
|
+
xpath(%w[Hot-Water-Store-Insulation-Type])
|
27
|
+
end
|
28
|
+
|
29
|
+
def cylinder_size
|
30
|
+
xpath(%w[Hot-Water-Store-Size])
|
31
|
+
end
|
32
|
+
|
33
|
+
def has_cylinder_thermostat
|
34
|
+
xpath(%w[Has-Cylinder-Thermostat])
|
35
|
+
end
|
36
|
+
|
37
|
+
def mech_vent_sys_index_number
|
38
|
+
xpath(%w[Mechanical-Vent-System-Index-Number])
|
39
|
+
end
|
40
|
+
|
41
|
+
def mechanical_vent_data_source
|
42
|
+
xpath(%w[Mechanical-Ventilation-Data-Source])
|
43
|
+
end
|
44
|
+
|
45
|
+
def thermal_store
|
46
|
+
xpath(%w[Thermal-Store])
|
47
|
+
end
|
20
48
|
end
|
21
49
|
end
|
22
50
|
end
|
@@ -72,6 +72,34 @@ module ViewModel
|
|
72
72
|
def energy_tariff
|
73
73
|
xpath(%w[Meter-Type])
|
74
74
|
end
|
75
|
+
|
76
|
+
def cylinder_insul_thickness
|
77
|
+
xpath(%w[Cylinder-Insulation-Thickness])
|
78
|
+
end
|
79
|
+
|
80
|
+
def cylinder_insulation_type
|
81
|
+
xpath(%w[Cylinder-Insulation-Type])
|
82
|
+
end
|
83
|
+
|
84
|
+
def cylinder_size
|
85
|
+
xpath(%w[Cylinder-Size])
|
86
|
+
end
|
87
|
+
|
88
|
+
def has_cylinder_thermostat
|
89
|
+
xpath(%w[Cylinder-Thermostat])
|
90
|
+
end
|
91
|
+
|
92
|
+
def mech_vent_sys_index_number
|
93
|
+
nil
|
94
|
+
end
|
95
|
+
|
96
|
+
def mechanical_vent_data_source
|
97
|
+
nil
|
98
|
+
end
|
99
|
+
|
100
|
+
def thermal_store
|
101
|
+
nil
|
102
|
+
end
|
75
103
|
end
|
76
104
|
end
|
77
105
|
end
|
@@ -17,6 +17,34 @@ module ViewModel
|
|
17
17
|
def construction_year
|
18
18
|
xpath(%w[Construction-Year])
|
19
19
|
end
|
20
|
+
|
21
|
+
def cylinder_insul_thickness
|
22
|
+
xpath(%w[Hot-Water-Store-Insulation-Thickness])
|
23
|
+
end
|
24
|
+
|
25
|
+
def cylinder_insulation_type
|
26
|
+
xpath(%w[Hot-Water-Store-Insulation-Type])
|
27
|
+
end
|
28
|
+
|
29
|
+
def cylinder_size
|
30
|
+
xpath(%w[Hot-Water-Store-Size])
|
31
|
+
end
|
32
|
+
|
33
|
+
def has_cylinder_thermostat
|
34
|
+
xpath(%w[Has-Cylinder-Thermostat])
|
35
|
+
end
|
36
|
+
|
37
|
+
def mech_vent_sys_index_number
|
38
|
+
xpath(%w[Mechanical-Vent-System-Index-Number])
|
39
|
+
end
|
40
|
+
|
41
|
+
def mechanical_vent_data_source
|
42
|
+
xpath(%w[Mechanical-Ventilation-Data-Source])
|
43
|
+
end
|
44
|
+
|
45
|
+
def thermal_store
|
46
|
+
xpath(%w[Thermal-Store])
|
47
|
+
end
|
20
48
|
end
|
21
49
|
end
|
22
50
|
end
|
@@ -72,6 +72,34 @@ module ViewModel
|
|
72
72
|
def energy_tariff
|
73
73
|
xpath(%w[Meter-Type])
|
74
74
|
end
|
75
|
+
|
76
|
+
def cylinder_insul_thickness
|
77
|
+
xpath(%w[Cylinder-Insulation-Thickness])
|
78
|
+
end
|
79
|
+
|
80
|
+
def cylinder_insulation_type
|
81
|
+
xpath(%w[Cylinder-Insulation-Type])
|
82
|
+
end
|
83
|
+
|
84
|
+
def cylinder_size
|
85
|
+
xpath(%w[Cylinder-Size])
|
86
|
+
end
|
87
|
+
|
88
|
+
def has_cylinder_thermostat
|
89
|
+
xpath(%w[Cylinder-Thermostat])
|
90
|
+
end
|
91
|
+
|
92
|
+
def mech_vent_sys_index_number
|
93
|
+
nil
|
94
|
+
end
|
95
|
+
|
96
|
+
def mechanical_vent_data_source
|
97
|
+
nil
|
98
|
+
end
|
99
|
+
|
100
|
+
def thermal_store
|
101
|
+
nil
|
102
|
+
end
|
75
103
|
end
|
76
104
|
end
|
77
105
|
end
|
@@ -17,6 +17,34 @@ module ViewModel
|
|
17
17
|
def construction_year
|
18
18
|
xpath(%w[Construction-Year])
|
19
19
|
end
|
20
|
+
|
21
|
+
def cylinder_insul_thickness
|
22
|
+
xpath(%w[Hot-Water-Store-Insulation-Thickness])
|
23
|
+
end
|
24
|
+
|
25
|
+
def cylinder_insulation_type
|
26
|
+
xpath(%w[Hot-Water-Store-Insulation-Type])
|
27
|
+
end
|
28
|
+
|
29
|
+
def cylinder_size
|
30
|
+
xpath(%w[Hot-Water-Store-Size])
|
31
|
+
end
|
32
|
+
|
33
|
+
def has_cylinder_thermostat
|
34
|
+
xpath(%w[Has-Cylinder-Thermostat])
|
35
|
+
end
|
36
|
+
|
37
|
+
def mech_vent_sys_index_number
|
38
|
+
xpath(%w[Mechanical-Vent-System-Index-Number])
|
39
|
+
end
|
40
|
+
|
41
|
+
def mechanical_vent_data_source
|
42
|
+
xpath(%w[Mechanical-Ventilation-Data-Source])
|
43
|
+
end
|
44
|
+
|
45
|
+
def thermal_store
|
46
|
+
xpath(%w[Thermal-Store])
|
47
|
+
end
|
20
48
|
end
|
21
49
|
end
|
22
50
|
end
|
@@ -68,6 +68,34 @@ module ViewModel
|
|
68
68
|
def energy_tariff
|
69
69
|
xpath(%w[Meter-Type])
|
70
70
|
end
|
71
|
+
|
72
|
+
def cylinder_insul_thickness
|
73
|
+
xpath(%w[Cylinder-Insulation-Thickness])
|
74
|
+
end
|
75
|
+
|
76
|
+
def cylinder_insulation_type
|
77
|
+
xpath(%w[Cylinder-Insulation-Type])
|
78
|
+
end
|
79
|
+
|
80
|
+
def cylinder_size
|
81
|
+
xpath(%w[Cylinder-Size])
|
82
|
+
end
|
83
|
+
|
84
|
+
def has_cylinder_thermostat
|
85
|
+
xpath(%w[Cylinder-Thermostat])
|
86
|
+
end
|
87
|
+
|
88
|
+
def mech_vent_sys_index_number
|
89
|
+
nil
|
90
|
+
end
|
91
|
+
|
92
|
+
def mechanical_vent_data_source
|
93
|
+
nil
|
94
|
+
end
|
95
|
+
|
96
|
+
def thermal_store
|
97
|
+
nil
|
98
|
+
end
|
71
99
|
end
|
72
100
|
end
|
73
101
|
end
|
@@ -17,6 +17,34 @@ module ViewModel
|
|
17
17
|
def construction_year
|
18
18
|
xpath(%w[Construction-Year])
|
19
19
|
end
|
20
|
+
|
21
|
+
def cylinder_insul_thickness
|
22
|
+
xpath(%w[Hot-Water-Store-Insulation-Thickness])
|
23
|
+
end
|
24
|
+
|
25
|
+
def cylinder_insulation_type
|
26
|
+
xpath(%w[Hot-Water-Store-Insulation-Type])
|
27
|
+
end
|
28
|
+
|
29
|
+
def cylinder_size
|
30
|
+
xpath(%w[Hot-Water-Store-Size])
|
31
|
+
end
|
32
|
+
|
33
|
+
def has_cylinder_thermostat
|
34
|
+
xpath(%w[Has-Cylinder-Thermostat])
|
35
|
+
end
|
36
|
+
|
37
|
+
def mech_vent_sys_index_number
|
38
|
+
xpath(%w[Mechanical-Vent-System-Index-Number])
|
39
|
+
end
|
40
|
+
|
41
|
+
def mechanical_vent_data_source
|
42
|
+
xpath(%w[Mechanical-Ventilation-Data-Source])
|
43
|
+
end
|
44
|
+
|
45
|
+
def thermal_store
|
46
|
+
xpath(%w[Thermal-Store])
|
47
|
+
end
|
20
48
|
end
|
21
49
|
end
|
22
50
|
end
|