epb_view_models 1.0.0 → 1.0.4
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +4 -4
- data/.buildspec.yml +13 -0
- data/.gitignore +5 -0
- data/.ruby-version +1 -0
- data/Gemfile.lock +22 -17
- data/Makefile +1 -1
- data/api/schemas/xml/RdSAP-Schema-NI-19.0/RdSAP/Templates/EPC-CollectedData.xsd +13 -12
- data/lib/epb_view_models.rb +1 -1
- data/lib/helper/ac_report_extraction.rb +26 -28
- data/lib/helper/energy_band_calculator.rb +1 -1
- data/lib/helper/xml_enums_to_output.rb +286 -126
- data/lib/presenter/cepc/report.rb +5 -2
- data/lib/presenter/dec/report.rb +5 -2
- data/lib/presenter/export/domestic.rb +1 -1
- data/lib/presenter/rd_sap/report.rb +213 -5
- data/lib/presenter/sap/report.rb +213 -4
- data/lib/presenter/sap/summary.rb +1 -1
- data/lib/view_model/cepc50/cepc.rb +0 -4
- data/lib/view_model/cepc60/cepc.rb +0 -4
- data/lib/view_model/cepc71/dec.rb +0 -4
- data/lib/view_model/cepc_ni800/ac_report.rb +3 -2
- data/lib/view_model/domestic_epc_view_model.rb +4 -0
- data/lib/view_model/rd_sap_schema_170/common_schema.rb +16 -0
- data/lib/view_model/rd_sap_schema_171/common_schema.rb +16 -0
- data/lib/view_model/rd_sap_schema_180/common_schema.rb +16 -0
- data/lib/view_model/rd_sap_schema_190/common_schema.rb +16 -0
- data/lib/view_model/rd_sap_schema_200/common_schema.rb +16 -8
- data/lib/view_model/rd_sap_schema_ni_173/common_schema.rb +16 -0
- data/lib/view_model/rd_sap_schema_ni_174/common_schema.rb +16 -0
- data/lib/view_model/rd_sap_schema_ni_180/common_schema.rb +16 -0
- data/lib/view_model/rd_sap_schema_ni_190/common_schema.rb +16 -0
- data/lib/view_model/rd_sap_schema_ni_200/common_schema.rb +16 -4
- data/lib/view_model/rd_sap_wrapper.rb +4 -0
- data/lib/view_model/sap_schema_102/common_schema.rb +33 -10
- data/lib/view_model/sap_schema_102/rdsap.rb +8 -0
- data/lib/view_model/sap_schema_110/common_schema.rb +1 -10
- data/lib/view_model/sap_schema_110/rdsap.rb +36 -0
- data/lib/view_model/sap_schema_110/sap.rb +36 -0
- data/lib/view_model/sap_schema_112/common_schema.rb +1 -10
- data/lib/view_model/sap_schema_112/rdsap.rb +36 -0
- data/lib/view_model/sap_schema_112/sap.rb +36 -0
- data/lib/view_model/sap_schema_120/common_schema.rb +0 -12
- data/lib/view_model/sap_schema_120/rdsap.rb +36 -0
- data/lib/view_model/sap_schema_120/sap.rb +36 -0
- data/lib/view_model/sap_schema_130/common_schema.rb +0 -4
- data/lib/view_model/sap_schema_130/rdsap.rb +36 -0
- data/lib/view_model/sap_schema_130/sap.rb +36 -0
- data/lib/view_model/sap_schema_140/common_schema.rb +0 -8
- data/lib/view_model/sap_schema_140/rdsap.rb +36 -0
- data/lib/view_model/sap_schema_140/sap.rb +36 -0
- data/lib/view_model/sap_schema_141/common_schema.rb +0 -4
- data/lib/view_model/sap_schema_141/rdsap.rb +36 -0
- data/lib/view_model/sap_schema_141/sap.rb +36 -0
- data/lib/view_model/sap_schema_142/common_schema.rb +0 -4
- data/lib/view_model/sap_schema_142/rdsap.rb +36 -0
- data/lib/view_model/sap_schema_142/sap.rb +36 -0
- data/lib/view_model/sap_schema_150/common_schema.rb +0 -4
- data/lib/view_model/sap_schema_150/rdsap.rb +36 -0
- data/lib/view_model/sap_schema_150/sap.rb +36 -0
- data/lib/view_model/sap_schema_160/common_schema.rb +0 -4
- data/lib/view_model/sap_schema_160/rdsap.rb +36 -0
- data/lib/view_model/sap_schema_160/sap.rb +36 -0
- data/lib/view_model/sap_schema_161/common_schema.rb +0 -4
- data/lib/view_model/sap_schema_161/rdsap.rb +36 -0
- data/lib/view_model/sap_schema_161/sap.rb +36 -0
- data/lib/view_model/sap_schema_162/common_schema.rb +0 -4
- data/lib/view_model/sap_schema_162/rdsap.rb +36 -0
- data/lib/view_model/sap_schema_162/sap.rb +36 -0
- data/lib/view_model/sap_schema_163/common_schema.rb +0 -4
- data/lib/view_model/sap_schema_163/rdsap.rb +36 -0
- data/lib/view_model/sap_schema_163/sap.rb +36 -0
- data/lib/view_model/sap_schema_170/common_schema.rb +32 -0
- data/lib/view_model/sap_schema_171/common_schema.rb +32 -4
- data/lib/view_model/sap_schema_1800/common_schema.rb +32 -8
- data/lib/view_model/sap_schema_ni_112/common_schema.rb +1 -5
- data/lib/view_model/sap_schema_ni_112/rdsap.rb +45 -4
- data/lib/view_model/sap_schema_ni_112/sap.rb +35 -0
- data/lib/view_model/sap_schema_ni_120/common_schema.rb +1 -5
- data/lib/view_model/sap_schema_ni_120/rdsap.rb +40 -0
- data/lib/view_model/sap_schema_ni_120/sap.rb +36 -0
- data/lib/view_model/sap_schema_ni_130/common_schema.rb +1 -5
- data/lib/view_model/sap_schema_ni_130/rdsap.rb +40 -0
- data/lib/view_model/sap_schema_ni_130/sap.rb +36 -0
- data/lib/view_model/sap_schema_ni_140/common_schema.rb +1 -5
- data/lib/view_model/sap_schema_ni_140/rdsap.rb +40 -0
- data/lib/view_model/sap_schema_ni_140/sap.rb +36 -0
- data/lib/view_model/sap_schema_ni_141/common_schema.rb +1 -5
- data/lib/view_model/sap_schema_ni_141/rdsap.rb +40 -0
- data/lib/view_model/sap_schema_ni_141/sap.rb +36 -0
- data/lib/view_model/sap_schema_ni_142/common_schema.rb +1 -5
- data/lib/view_model/sap_schema_ni_142/rdsap.rb +40 -0
- data/lib/view_model/sap_schema_ni_142/sap.rb +36 -0
- data/lib/view_model/sap_schema_ni_150/common_schema.rb +1 -5
- data/lib/view_model/sap_schema_ni_150/rdsap.rb +40 -0
- data/lib/view_model/sap_schema_ni_150/sap.rb +36 -0
- data/lib/view_model/sap_schema_ni_160/common_schema.rb +2 -6
- data/lib/view_model/sap_schema_ni_160/rdsap.rb +36 -0
- data/lib/view_model/sap_schema_ni_160/sap.rb +36 -0
- data/lib/view_model/sap_schema_ni_161/common_schema.rb +1 -5
- data/lib/view_model/sap_schema_ni_161/rdsap.rb +36 -0
- data/lib/view_model/sap_schema_ni_161/sap.rb +36 -0
- data/lib/view_model/sap_schema_ni_170/common_schema.rb +0 -4
- data/lib/view_model/sap_schema_ni_170/rdsap.rb +36 -0
- data/lib/view_model/sap_schema_ni_170/sap.rb +36 -0
- data/lib/view_model/sap_schema_ni_171/common_schema.rb +0 -4
- data/lib/view_model/sap_schema_ni_171/rdsap.rb +36 -0
- data/lib/view_model/sap_schema_ni_171/sap.rb +36 -0
- data/lib/view_model/sap_schema_ni_172/common_schema.rb +0 -4
- data/lib/view_model/sap_schema_ni_172/rdsap.rb +44 -0
- data/lib/view_model/sap_schema_ni_172/sap.rb +36 -0
- data/lib/view_model/sap_schema_ni_173/common_schema.rb +32 -0
- data/lib/view_model/sap_schema_ni_174/common_schema.rb +32 -0
- data/lib/view_model/sap_schema_ni_1800/common_schema.rb +32 -22
- data/lib/view_model/sap_wrapper.rb +4 -0
- metadata +4 -2
@@ -81,6 +81,42 @@ module ViewModel
|
|
81
81
|
def energy_tariff
|
82
82
|
xpath(%w[Meter-Type])
|
83
83
|
end
|
84
|
+
|
85
|
+
def cylinder_insul_thickness
|
86
|
+
xpath(%w[Cylinder-Insulation-Thickness])
|
87
|
+
end
|
88
|
+
|
89
|
+
def cylinder_insulation_type
|
90
|
+
xpath(%w[Cylinder-Insulation-Type])
|
91
|
+
end
|
92
|
+
|
93
|
+
def cylinder_size
|
94
|
+
xpath(%w[Cylinder-Size])
|
95
|
+
end
|
96
|
+
|
97
|
+
def has_cylinder_thermostat
|
98
|
+
xpath(%w[Cylinder-Thermostat])
|
99
|
+
end
|
100
|
+
|
101
|
+
def mech_vent_sys_index_number
|
102
|
+
nil
|
103
|
+
end
|
104
|
+
|
105
|
+
def mechanical_vent_data_source
|
106
|
+
nil
|
107
|
+
end
|
108
|
+
|
109
|
+
def thermal_store
|
110
|
+
nil
|
111
|
+
end
|
112
|
+
|
113
|
+
def water_heating_fuel
|
114
|
+
xpath(%w[Water-Heating-Fuel])
|
115
|
+
end
|
116
|
+
|
117
|
+
def ventilation_type
|
118
|
+
nil
|
119
|
+
end
|
84
120
|
end
|
85
121
|
end
|
86
122
|
end
|
@@ -20,6 +20,42 @@ module ViewModel
|
|
20
20
|
end
|
21
21
|
nil
|
22
22
|
end
|
23
|
+
|
24
|
+
def cylinder_insul_thickness
|
25
|
+
xpath(%w[Hot-Water-Store-Insulation-Thickness])
|
26
|
+
end
|
27
|
+
|
28
|
+
def cylinder_insulation_type
|
29
|
+
xpath(%w[Hot-Water-Store-Insulation-Type])
|
30
|
+
end
|
31
|
+
|
32
|
+
def cylinder_size
|
33
|
+
xpath(%w[Hot-Water-Store-Size])
|
34
|
+
end
|
35
|
+
|
36
|
+
def has_cylinder_thermostat
|
37
|
+
xpath(%w[Has-Cylinder-Thermostat])
|
38
|
+
end
|
39
|
+
|
40
|
+
def mech_vent_sys_index_number
|
41
|
+
xpath(%w[Mechanical-Vent-System-Index-Number])
|
42
|
+
end
|
43
|
+
|
44
|
+
def mechanical_vent_data_source
|
45
|
+
xpath(%w[Mechanical-Ventilation-Data-Source])
|
46
|
+
end
|
47
|
+
|
48
|
+
def thermal_store
|
49
|
+
xpath(%w[Thermal-Store])
|
50
|
+
end
|
51
|
+
|
52
|
+
def ventilation_type
|
53
|
+
xpath(%w[Ventilation-Type])
|
54
|
+
end
|
55
|
+
|
56
|
+
def water_heating_fuel
|
57
|
+
xpath(%w[Water-Fuel-Type])
|
58
|
+
end
|
23
59
|
end
|
24
60
|
end
|
25
61
|
end
|
@@ -244,10 +244,6 @@ module ViewModel
|
|
244
244
|
xpath(%w[Secondary-Fuel-Type])
|
245
245
|
end
|
246
246
|
|
247
|
-
def water_heating_fuel
|
248
|
-
xpath(%w[Water-Fuel-Type])
|
249
|
-
end
|
250
|
-
|
251
247
|
def type_of_assessment
|
252
248
|
case xpath(%w[Report-Type]).to_i
|
253
249
|
when 1
|
@@ -377,8 +373,7 @@ module ViewModel
|
|
377
373
|
end
|
378
374
|
|
379
375
|
def built_form
|
380
|
-
|
381
|
-
Helper::XmlEnumsToOutput.xml_value_to_string(built_form_value)
|
376
|
+
xpath(%w[Built-Form])
|
382
377
|
end
|
383
378
|
|
384
379
|
def heat_loss_corridor
|
@@ -491,10 +486,6 @@ module ViewModel
|
|
491
486
|
.map(&:content)
|
492
487
|
end
|
493
488
|
|
494
|
-
def transaction_type
|
495
|
-
nil
|
496
|
-
end
|
497
|
-
|
498
489
|
def main_dwelling_construction_age_band_or_year
|
499
490
|
sap_building_parts =
|
500
491
|
@xml_doc.xpath("//SAP-Building-Parts/SAP-Building-Part")
|
@@ -81,6 +81,42 @@ module ViewModel
|
|
81
81
|
def energy_tariff
|
82
82
|
xpath(%w[Meter-Type])
|
83
83
|
end
|
84
|
+
|
85
|
+
def cylinder_insul_thickness
|
86
|
+
xpath(%w[Cylinder-Insulation-Thickness])
|
87
|
+
end
|
88
|
+
|
89
|
+
def cylinder_insulation_type
|
90
|
+
xpath(%w[Cylinder-Insulation-Type])
|
91
|
+
end
|
92
|
+
|
93
|
+
def cylinder_size
|
94
|
+
xpath(%w[Cylinder-Size])
|
95
|
+
end
|
96
|
+
|
97
|
+
def has_cylinder_thermostat
|
98
|
+
xpath(%w[Cylinder-Thermostat])
|
99
|
+
end
|
100
|
+
|
101
|
+
def mech_vent_sys_index_number
|
102
|
+
nil
|
103
|
+
end
|
104
|
+
|
105
|
+
def mechanical_vent_data_source
|
106
|
+
nil
|
107
|
+
end
|
108
|
+
|
109
|
+
def thermal_store
|
110
|
+
nil
|
111
|
+
end
|
112
|
+
|
113
|
+
def ventilation_type
|
114
|
+
nil
|
115
|
+
end
|
116
|
+
|
117
|
+
def water_heating_fuel
|
118
|
+
xpath(%w[Water-Heating-Fuel])
|
119
|
+
end
|
84
120
|
end
|
85
121
|
end
|
86
122
|
end
|
@@ -26,6 +26,42 @@ module ViewModel
|
|
26
26
|
end
|
27
27
|
nil
|
28
28
|
end
|
29
|
+
|
30
|
+
def cylinder_insul_thickness
|
31
|
+
xpath(%w[Hot-Water-Store-Insulation-Thickness])
|
32
|
+
end
|
33
|
+
|
34
|
+
def cylinder_insulation_type
|
35
|
+
xpath(%w[Hot-Water-Store-Insulation-Type])
|
36
|
+
end
|
37
|
+
|
38
|
+
def cylinder_size
|
39
|
+
xpath(%w[Hot-Water-Store-Size])
|
40
|
+
end
|
41
|
+
|
42
|
+
def has_cylinder_thermostat
|
43
|
+
xpath(%w[Has-Cylinder-Thermostat])
|
44
|
+
end
|
45
|
+
|
46
|
+
def mech_vent_sys_index_number
|
47
|
+
xpath(%w[Mechanical-Vent-System-Index-Number])
|
48
|
+
end
|
49
|
+
|
50
|
+
def mechanical_vent_data_source
|
51
|
+
xpath(%w[Mechanical-Ventilation-Data-Source])
|
52
|
+
end
|
53
|
+
|
54
|
+
def thermal_store
|
55
|
+
xpath(%w[Thermal-Store])
|
56
|
+
end
|
57
|
+
|
58
|
+
def ventilation_type
|
59
|
+
xpath(%w[Ventilation-Type])
|
60
|
+
end
|
61
|
+
|
62
|
+
def water_heating_fuel
|
63
|
+
xpath(%w[Water-Fuel-Type])
|
64
|
+
end
|
29
65
|
end
|
30
66
|
end
|
31
67
|
end
|
@@ -244,10 +244,6 @@ module ViewModel
|
|
244
244
|
xpath(%w[Secondary-Fuel-Type])
|
245
245
|
end
|
246
246
|
|
247
|
-
def water_heating_fuel
|
248
|
-
xpath(%w[Water-Fuel-Type])
|
249
|
-
end
|
250
|
-
|
251
247
|
def type_of_assessment
|
252
248
|
case xpath(%w[Report-Type]).to_i
|
253
249
|
when 1
|
@@ -392,10 +388,6 @@ module ViewModel
|
|
392
388
|
xpath(%w[Wind-Turbines-Count])
|
393
389
|
end
|
394
390
|
|
395
|
-
def unheated_corridor_length
|
396
|
-
xpath(%w[Unheated-Corridor-Length])
|
397
|
-
end
|
398
|
-
|
399
391
|
def all_main_heating_descriptions
|
400
392
|
@xml_doc.search("Main-Heating/Description").map(&:content)
|
401
393
|
end
|
@@ -494,10 +486,6 @@ module ViewModel
|
|
494
486
|
@xml_doc.search("Storey-Height").map(&:content)
|
495
487
|
end
|
496
488
|
|
497
|
-
def all_main_heating_energy_efficiency
|
498
|
-
@xml_doc.search("Main-Heating/Energy-Efficiency-Rating").map(&:content)
|
499
|
-
end
|
500
|
-
|
501
489
|
def all_main_heating_controls_energy_efficiency
|
502
490
|
@xml_doc
|
503
491
|
.search("Main-Heating-Controls/Energy-Efficiency-Rating")
|
@@ -64,6 +64,42 @@ module ViewModel
|
|
64
64
|
def energy_tariff
|
65
65
|
xpath(%w[Meter-Type])
|
66
66
|
end
|
67
|
+
|
68
|
+
def cylinder_insul_thickness
|
69
|
+
xpath(%w[Cylinder-Insulation-Thickness])
|
70
|
+
end
|
71
|
+
|
72
|
+
def cylinder_insulation_type
|
73
|
+
xpath(%w[Cylinder-Insulation-Type])
|
74
|
+
end
|
75
|
+
|
76
|
+
def cylinder_size
|
77
|
+
xpath(%w[Cylinder-Size])
|
78
|
+
end
|
79
|
+
|
80
|
+
def has_cylinder_thermostat
|
81
|
+
xpath(%w[Cylinder-Thermostat])
|
82
|
+
end
|
83
|
+
|
84
|
+
def mech_vent_sys_index_number
|
85
|
+
nil
|
86
|
+
end
|
87
|
+
|
88
|
+
def mechanical_vent_data_source
|
89
|
+
nil
|
90
|
+
end
|
91
|
+
|
92
|
+
def thermal_store
|
93
|
+
nil
|
94
|
+
end
|
95
|
+
|
96
|
+
def ventilation_type
|
97
|
+
nil
|
98
|
+
end
|
99
|
+
|
100
|
+
def water_heating_fuel
|
101
|
+
xpath(%w[Water-Heating-Fuel])
|
102
|
+
end
|
67
103
|
end
|
68
104
|
end
|
69
105
|
end
|
@@ -8,6 +8,42 @@ module ViewModel
|
|
8
8
|
def construction_year
|
9
9
|
xpath(%w[Construction-Year])
|
10
10
|
end
|
11
|
+
|
12
|
+
def cylinder_insul_thickness
|
13
|
+
xpath(%w[Hot-Water-Store-Insulation-Thickness])
|
14
|
+
end
|
15
|
+
|
16
|
+
def cylinder_insulation_type
|
17
|
+
xpath(%w[Hot-Water-Store-Insulation-Type])
|
18
|
+
end
|
19
|
+
|
20
|
+
def cylinder_size
|
21
|
+
xpath(%w[Hot-Water-Store-Size])
|
22
|
+
end
|
23
|
+
|
24
|
+
def has_cylinder_thermostat
|
25
|
+
xpath(%w[Has-Cylinder-Thermostat])
|
26
|
+
end
|
27
|
+
|
28
|
+
def mech_vent_sys_index_number
|
29
|
+
xpath(%w[Mechanical-Vent-System-Index-Number])
|
30
|
+
end
|
31
|
+
|
32
|
+
def mechanical_vent_data_source
|
33
|
+
xpath(%w[Mechanical-Ventilation-Data-Source])
|
34
|
+
end
|
35
|
+
|
36
|
+
def thermal_store
|
37
|
+
xpath(%w[Thermal-Store])
|
38
|
+
end
|
39
|
+
|
40
|
+
def ventilation_type
|
41
|
+
xpath(%w[Ventilation-Type])
|
42
|
+
end
|
43
|
+
|
44
|
+
def water_heating_fuel
|
45
|
+
xpath(%w[Water-Fuel-Type])
|
46
|
+
end
|
11
47
|
end
|
12
48
|
end
|
13
49
|
end
|
@@ -64,6 +64,42 @@ module ViewModel
|
|
64
64
|
def energy_tariff
|
65
65
|
xpath(%w[Meter-Type])
|
66
66
|
end
|
67
|
+
|
68
|
+
def cylinder_insul_thickness
|
69
|
+
xpath(%w[Cylinder-Insulation-Thickness])
|
70
|
+
end
|
71
|
+
|
72
|
+
def cylinder_insulation_type
|
73
|
+
xpath(%w[Cylinder-Insulation-Type])
|
74
|
+
end
|
75
|
+
|
76
|
+
def cylinder_size
|
77
|
+
xpath(%w[Cylinder-Size])
|
78
|
+
end
|
79
|
+
|
80
|
+
def has_cylinder_thermostat
|
81
|
+
xpath(%w[Cylinder-Thermostat])
|
82
|
+
end
|
83
|
+
|
84
|
+
def mech_vent_sys_index_number
|
85
|
+
nil
|
86
|
+
end
|
87
|
+
|
88
|
+
def mechanical_vent_data_source
|
89
|
+
nil
|
90
|
+
end
|
91
|
+
|
92
|
+
def thermal_store
|
93
|
+
nil
|
94
|
+
end
|
95
|
+
|
96
|
+
def ventilation_type
|
97
|
+
nil
|
98
|
+
end
|
99
|
+
|
100
|
+
def water_heating_fuel
|
101
|
+
xpath(%w[Water-Heating-Fuel])
|
102
|
+
end
|
67
103
|
end
|
68
104
|
end
|
69
105
|
end
|
@@ -8,6 +8,42 @@ module ViewModel
|
|
8
8
|
def construction_year
|
9
9
|
xpath(%w[Construction-Year])
|
10
10
|
end
|
11
|
+
|
12
|
+
def cylinder_insul_thickness
|
13
|
+
xpath(%w[Hot-Water-Store-Insulation-Thickness])
|
14
|
+
end
|
15
|
+
|
16
|
+
def cylinder_insulation_type
|
17
|
+
xpath(%w[Hot-Water-Store-Insulation-Type])
|
18
|
+
end
|
19
|
+
|
20
|
+
def cylinder_size
|
21
|
+
xpath(%w[Hot-Water-Store-Size])
|
22
|
+
end
|
23
|
+
|
24
|
+
def has_cylinder_thermostat
|
25
|
+
xpath(%w[Has-Cylinder-Thermostat])
|
26
|
+
end
|
27
|
+
|
28
|
+
def mech_vent_sys_index_number
|
29
|
+
xpath(%w[Mechanical-Vent-System-Index-Number])
|
30
|
+
end
|
31
|
+
|
32
|
+
def mechanical_vent_data_source
|
33
|
+
xpath(%w[Mechanical-Ventilation-Data-Source])
|
34
|
+
end
|
35
|
+
|
36
|
+
def thermal_store
|
37
|
+
xpath(%w[Thermal-Store])
|
38
|
+
end
|
39
|
+
|
40
|
+
def ventilation_type
|
41
|
+
xpath(%w[Ventilation-Type])
|
42
|
+
end
|
43
|
+
|
44
|
+
def water_heating_fuel
|
45
|
+
xpath(%w[Water-Fuel-Type])
|
46
|
+
end
|
11
47
|
end
|
12
48
|
end
|
13
49
|
end
|
@@ -243,10 +243,6 @@ module ViewModel
|
|
243
243
|
xpath(%w[Secondary-Fuel-Type])
|
244
244
|
end
|
245
245
|
|
246
|
-
def water_heating_fuel
|
247
|
-
xpath(%w[Water-Fuel-Type])
|
248
|
-
end
|
249
|
-
|
250
246
|
def type_of_assessment
|
251
247
|
case xpath(%w[Report-Type]).to_i
|
252
248
|
when 1
|
@@ -391,10 +387,6 @@ module ViewModel
|
|
391
387
|
xpath(%w[Wind-Turbines-Count])
|
392
388
|
end
|
393
389
|
|
394
|
-
def unheated_corridor_length
|
395
|
-
xpath(%w[Unheated-Corridor-Length])
|
396
|
-
end
|
397
|
-
|
398
390
|
def all_main_heating_descriptions
|
399
391
|
@xml_doc.search("Main-Heating/Description").map(&:content)
|
400
392
|
end
|