ekm-omnimeter 0.2.1 → 0.2.2
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- checksums.yaml +4 -4
- data/README.md +1 -2
- data/lib/ekm-omnimeter/meter.rb +4 -5
- data/lib/ekm-omnimeter/version.rb +1 -1
- metadata +1 -1
checksums.yaml
CHANGED
@@ -1,7 +1,7 @@
|
|
1
1
|
---
|
2
2
|
SHA1:
|
3
|
-
metadata.gz:
|
4
|
-
data.tar.gz:
|
3
|
+
metadata.gz: 805b7edfbd3b7f9e44d1f93d0734abde1c97c3f0
|
4
|
+
data.tar.gz: db58b9036c43cbc237acca4560fca9d2b750ce68
|
5
5
|
SHA512:
|
6
|
-
metadata.gz:
|
7
|
-
data.tar.gz:
|
6
|
+
metadata.gz: 70814f2e75bc91c8d5d41266e1cc7ecfbb636d2ec8852ba5a358de3d177fc03cea9b73c55b059fcbcd314702183f15a87601e6fcba9fe5429a6446b1622faa59
|
7
|
+
data.tar.gz: 92c36cd70fd8888eb5ad3c796cfc01d1f353fb3f3ecba13a176a27963f349739edca2273a232bca87879c4a83a84cd5eb30ce6accbef01026824c3378b49fb7b
|
data/README.md
CHANGED
@@ -13,7 +13,6 @@ contains a revenue-grade universal kWh power meter, three pulse counting inputs
|
|
13
13
|
and 2 controllable 50 mA at 12 volts relay outputs that can toggle 120v circuits when connected to their [EKM Switch120 power cord](http://www.ekmmetering.com/ekm-metering-products/accessories/switch120.html).
|
14
14
|
|
15
15
|
TODO:
|
16
|
-
* Cast values to their proper type and precision
|
17
16
|
* Add specs
|
18
17
|
* Add daemon to monitor meter's output at regular intervals
|
19
18
|
|
@@ -89,7 +88,7 @@ m.watts_total # 2664
|
|
89
88
|
m.power_factor_1 # 1.0
|
90
89
|
m.power_factor_2 # 0.0
|
91
90
|
m.power_factor_3 # 0.0
|
92
|
-
m.maximum_demand #
|
91
|
+
m.maximum_demand # 22640.0
|
93
92
|
m.maximum_demand_period # 1
|
94
93
|
m.ct_ratio # 400
|
95
94
|
m.pulse_1_count # 3
|
data/lib/ekm-omnimeter/meter.rb
CHANGED
@@ -160,7 +160,6 @@ module EkmOmnimeter
|
|
160
160
|
|
161
161
|
# Returns the correct measurement for voltage, current, and power based on the corresponding power_configuration
|
162
162
|
def calculate_measurement(m1, m2, m3)
|
163
|
-
puts "****** #{power_configuration.inspect} #{m1}, #{m2}, #{m3}"
|
164
163
|
if power_configuration == :single_phase_2wire
|
165
164
|
m1
|
166
165
|
elsif power_configuration == :single_phase_3wire
|
@@ -194,7 +193,6 @@ module EkmOmnimeter
|
|
194
193
|
:watts_l2,
|
195
194
|
:watts_l3,
|
196
195
|
:watts_total,
|
197
|
-
:maximum_demand,
|
198
196
|
:ct_ratio,
|
199
197
|
:pulse_1_count,
|
200
198
|
:pulse_1_ratio,
|
@@ -218,7 +216,8 @@ module EkmOmnimeter
|
|
218
216
|
:volts_l3,
|
219
217
|
:amps_l1,
|
220
218
|
:amps_l2,
|
221
|
-
:amps_l3
|
219
|
+
:amps_l3,
|
220
|
+
:maximum_demand
|
222
221
|
].each do |k|
|
223
222
|
logger.debug "Casting #{k}"
|
224
223
|
d[k] = to_f_with_decimal_places(d[k], 1) if d.has_key?(k)
|
@@ -276,7 +275,7 @@ module EkmOmnimeter
|
|
276
275
|
response = get_remote_meter_data(request, read_bytes)
|
277
276
|
|
278
277
|
if response.nil?
|
279
|
-
|
278
|
+
logger.error "No response to request_a from meter #{meter_number}"
|
280
279
|
raise EkmOmnimeter, "No response from meter."
|
281
280
|
end
|
282
281
|
|
@@ -370,7 +369,7 @@ module EkmOmnimeter
|
|
370
369
|
logger.debug "Socket write #{request}" unless logger.nil?
|
371
370
|
response = get_remote_meter_data(request, read_bytes)
|
372
371
|
if response.nil?
|
373
|
-
|
372
|
+
logger.error "No response to request_a from meter #{meter_number}"
|
374
373
|
raise EkmOmnimeter, "No response from meter."
|
375
374
|
end
|
376
375
|
|