ekm-omnimeter 0.2.1 → 0.2.2

Sign up to get free protection for your applications and to get access to all the features.
checksums.yaml CHANGED
@@ -1,7 +1,7 @@
1
1
  ---
2
2
  SHA1:
3
- metadata.gz: 956b201ecc8c116268db81bb760d33d6f8a1fc64
4
- data.tar.gz: b7ad7042d5e54af49457484ac419a9036727136f
3
+ metadata.gz: 805b7edfbd3b7f9e44d1f93d0734abde1c97c3f0
4
+ data.tar.gz: db58b9036c43cbc237acca4560fca9d2b750ce68
5
5
  SHA512:
6
- metadata.gz: 9746afa0fcbad02f08d06f82c316ee90793396afe7c8a8088d6042ed33780711e1d31d6a6469bbb9ac1c53ff6178cefc4455bddd64dbf6358e1b0ec72e2e61fa
7
- data.tar.gz: c5cbd6cbd05c2fe74caed67c2a64a2e69c4c098d5fa490d671821dca18db0a7623b1f76504b7d9566ab9a1e3d7a93ff207ebf36facf506594f77f15a887f65a7
6
+ metadata.gz: 70814f2e75bc91c8d5d41266e1cc7ecfbb636d2ec8852ba5a358de3d177fc03cea9b73c55b059fcbcd314702183f15a87601e6fcba9fe5429a6446b1622faa59
7
+ data.tar.gz: 92c36cd70fd8888eb5ad3c796cfc01d1f353fb3f3ecba13a176a27963f349739edca2273a232bca87879c4a83a84cd5eb30ce6accbef01026824c3378b49fb7b
data/README.md CHANGED
@@ -13,7 +13,6 @@ contains a revenue-grade universal kWh power meter, three pulse counting inputs
13
13
  and 2 controllable 50 mA at 12 volts relay outputs that can toggle 120v circuits when connected to their [EKM Switch120 power cord](http://www.ekmmetering.com/ekm-metering-products/accessories/switch120.html).
14
14
 
15
15
  TODO:
16
- * Cast values to their proper type and precision
17
16
  * Add specs
18
17
  * Add daemon to monitor meter's output at regular intervals
19
18
 
@@ -89,7 +88,7 @@ m.watts_total # 2664
89
88
  m.power_factor_1 # 1.0
90
89
  m.power_factor_2 # 0.0
91
90
  m.power_factor_3 # 0.0
92
- m.maximum_demand # 226400
91
+ m.maximum_demand # 22640.0
93
92
  m.maximum_demand_period # 1
94
93
  m.ct_ratio # 400
95
94
  m.pulse_1_count # 3
@@ -160,7 +160,6 @@ module EkmOmnimeter
160
160
 
161
161
  # Returns the correct measurement for voltage, current, and power based on the corresponding power_configuration
162
162
  def calculate_measurement(m1, m2, m3)
163
- puts "****** #{power_configuration.inspect} #{m1}, #{m2}, #{m3}"
164
163
  if power_configuration == :single_phase_2wire
165
164
  m1
166
165
  elsif power_configuration == :single_phase_3wire
@@ -194,7 +193,6 @@ module EkmOmnimeter
194
193
  :watts_l2,
195
194
  :watts_l3,
196
195
  :watts_total,
197
- :maximum_demand,
198
196
  :ct_ratio,
199
197
  :pulse_1_count,
200
198
  :pulse_1_ratio,
@@ -218,7 +216,8 @@ module EkmOmnimeter
218
216
  :volts_l3,
219
217
  :amps_l1,
220
218
  :amps_l2,
221
- :amps_l3
219
+ :amps_l3,
220
+ :maximum_demand
222
221
  ].each do |k|
223
222
  logger.debug "Casting #{k}"
224
223
  d[k] = to_f_with_decimal_places(d[k], 1) if d.has_key?(k)
@@ -276,7 +275,7 @@ module EkmOmnimeter
276
275
  response = get_remote_meter_data(request, read_bytes)
277
276
 
278
277
  if response.nil?
279
- log.error "No response to request_a from meter #{address}"
278
+ logger.error "No response to request_a from meter #{meter_number}"
280
279
  raise EkmOmnimeter, "No response from meter."
281
280
  end
282
281
 
@@ -370,7 +369,7 @@ module EkmOmnimeter
370
369
  logger.debug "Socket write #{request}" unless logger.nil?
371
370
  response = get_remote_meter_data(request, read_bytes)
372
371
  if response.nil?
373
- log.error "No response to request_a from meter #{address}"
372
+ logger.error "No response to request_a from meter #{meter_number}"
374
373
  raise EkmOmnimeter, "No response from meter."
375
374
  end
376
375
 
@@ -7,7 +7,7 @@ module EkmOmnimeter
7
7
  module VERSION #:nodoc:
8
8
  MAJOR = 0
9
9
  MINOR = 2
10
- PATCH = 1
10
+ PATCH = 2
11
11
 
12
12
  STRING = [MAJOR, MINOR, PATCH].join('.')
13
13
  end
metadata CHANGED
@@ -1,7 +1,7 @@
1
1
  --- !ruby/object:Gem::Specification
2
2
  name: ekm-omnimeter
3
3
  version: !ruby/object:Gem::Version
4
- version: 0.2.1
4
+ version: 0.2.2
5
5
  platform: ruby
6
6
  authors:
7
7
  - Jordan Duggan