apple-data 1.0.628 → 1.0.648

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (252) hide show
  1. checksums.yaml +4 -4
  2. data/lib/apple_data/data_file.rb +66 -18
  3. data/lib/apple_data/factory_data_reset.rb +32 -0
  4. data/lib/apple_data/io_reg.rb +60 -0
  5. data/lib/apple_data/ipsw.rb +17 -15
  6. data/lib/apple_data/keybag.rb +14 -18
  7. data/lib/apple_data/lockdown.rb +12 -12
  8. data/lib/apple_data/version.rb +1 -1
  9. data/lib/apple_data.rb +5 -7
  10. data/share/apns.yaml +24 -20
  11. data/share/backup.yaml +8 -8
  12. data/share/baseband/qualcomm/mav13.yaml +1 -0
  13. data/share/baseband/qualcomm/mav20.yaml +1 -0
  14. data/share/baseband/qualcomm/mav21.yaml +1 -0
  15. data/share/baseband.yaml +100 -60
  16. data/share/bluetooth.yaml +16 -14
  17. data/share/boot_args.yaml +12 -12
  18. data/share/bridgeos.yaml +18 -18
  19. data/share/bundles.yaml +61 -23
  20. data/share/coprocessor.yaml +165 -174
  21. data/share/credits.yaml +1 -0
  22. data/share/defaults.yaml +1 -0
  23. data/share/device_tree.yaml +1 -0
  24. data/share/devices/ADP3,1.yaml +1 -0
  25. data/share/devices/ADP3,2.yaml +1 -0
  26. data/share/devices/AppleTV5,3.yaml +1 -0
  27. data/share/devices/AudioAccessory5,1.yaml +1 -0
  28. data/share/devices/MacBookAir10,1.yaml +1 -0
  29. data/share/devices/MacBookPro17,1.yaml +1 -0
  30. data/share/devices/MacBookPro18,1.yaml +1 -0
  31. data/share/devices/MacBookPro18,2.yaml +1 -0
  32. data/share/devices/MacBookPro18,3.yaml +1 -0
  33. data/share/devices/MacBookPro18,4.yaml +1 -0
  34. data/share/devices/Macmini9,1.yaml +1 -0
  35. data/share/devices/VirtualMac2,1.yaml +1 -0
  36. data/share/devices/Watch3,1.yaml +1 -0
  37. data/share/devices/Watch3,2.yaml +1 -0
  38. data/share/devices/Watch3,3.yaml +1 -0
  39. data/share/devices/Watch3,4.yaml +1 -0
  40. data/share/devices/Watch4,1.yaml +1 -0
  41. data/share/devices/Watch4,2.yaml +1 -0
  42. data/share/devices/Watch4,3.yaml +1 -0
  43. data/share/devices/Watch4,4.yaml +1 -0
  44. data/share/devices/Watch5,1.yaml +1 -0
  45. data/share/devices/Watch5,10.yaml +1 -0
  46. data/share/devices/Watch5,11.yaml +1 -0
  47. data/share/devices/Watch5,12.yaml +1 -0
  48. data/share/devices/Watch5,2.yaml +1 -0
  49. data/share/devices/Watch5,3.yaml +1 -0
  50. data/share/devices/Watch5,4.yaml +1 -0
  51. data/share/devices/Watch5,9.yaml +1 -0
  52. data/share/devices/Watch6,1.yaml +1 -0
  53. data/share/devices/Watch6,2.yaml +1 -0
  54. data/share/devices/Watch6,3.yaml +1 -0
  55. data/share/devices/Watch6,4.yaml +1 -0
  56. data/share/devices/Watch6,6.yaml +1 -0
  57. data/share/devices/Watch6,7.yaml +1 -0
  58. data/share/devices/Watch6,8.yaml +1 -0
  59. data/share/devices/Watch6,9.yaml +1 -0
  60. data/share/devices/iBridge2,1.yaml +1 -0
  61. data/share/devices/iBridge2,10.yaml +1 -0
  62. data/share/devices/iBridge2,11.yaml +1 -0
  63. data/share/devices/iBridge2,12.yaml +1 -0
  64. data/share/devices/iBridge2,13.yaml +1 -0
  65. data/share/devices/iBridge2,14.yaml +1 -0
  66. data/share/devices/iBridge2,15.yaml +1 -0
  67. data/share/devices/iBridge2,16.yaml +1 -0
  68. data/share/devices/iBridge2,19.yaml +1 -0
  69. data/share/devices/iBridge2,20.yaml +1 -0
  70. data/share/devices/iBridge2,21.yaml +1 -0
  71. data/share/devices/iBridge2,22.yaml +1 -0
  72. data/share/devices/iBridge2,3.yaml +1 -0
  73. data/share/devices/iBridge2,4.yaml +1 -0
  74. data/share/devices/iBridge2,5.yaml +1 -0
  75. data/share/devices/iBridge2,6.yaml +1 -0
  76. data/share/devices/iBridge2,7.yaml +1 -0
  77. data/share/devices/iBridge2,8.yaml +1 -0
  78. data/share/devices/iMac21,1.yaml +1 -0
  79. data/share/devices/iMac21,2.yaml +1 -0
  80. data/share/devices/iPad11,1.yaml +1 -0
  81. data/share/devices/iPad11,2.yaml +1 -0
  82. data/share/devices/iPad11,3.yaml +1 -0
  83. data/share/devices/iPad11,4.yaml +1 -0
  84. data/share/devices/iPad11,6.yaml +1 -0
  85. data/share/devices/iPad11,7.yaml +1 -0
  86. data/share/devices/iPad12,1.yaml +1 -0
  87. data/share/devices/iPad12,2.yaml +1 -0
  88. data/share/devices/iPad13,1.yaml +1 -0
  89. data/share/devices/iPad13,10.yaml +1 -0
  90. data/share/devices/iPad13,11.yaml +1 -0
  91. data/share/devices/iPad13,16.yaml +1 -0
  92. data/share/devices/iPad13,17.yaml +1 -0
  93. data/share/devices/iPad13,2.yaml +1 -0
  94. data/share/devices/iPad13,4.yaml +1 -0
  95. data/share/devices/iPad13,5.yaml +1 -0
  96. data/share/devices/iPad13,6.yaml +1 -0
  97. data/share/devices/iPad13,7.yaml +1 -0
  98. data/share/devices/iPad13,8.yaml +1 -0
  99. data/share/devices/iPad13,9.yaml +1 -0
  100. data/share/devices/iPad14,1.yaml +1 -0
  101. data/share/devices/iPad14,2.yaml +1 -0
  102. data/share/devices/iPad4,1.yaml +1 -0
  103. data/share/devices/iPad4,2.yaml +1 -0
  104. data/share/devices/iPad4,3.yaml +1 -0
  105. data/share/devices/iPad4,4.yaml +1 -0
  106. data/share/devices/iPad4,5.yaml +1 -0
  107. data/share/devices/iPad4,6.yaml +1 -0
  108. data/share/devices/iPad4,7.yaml +1 -0
  109. data/share/devices/iPad4,8.yaml +1 -0
  110. data/share/devices/iPad4,9.yaml +1 -0
  111. data/share/devices/iPad5,1.yaml +1 -0
  112. data/share/devices/iPad5,2.yaml +1 -0
  113. data/share/devices/iPad5,3.yaml +1 -0
  114. data/share/devices/iPad5,4.yaml +1 -0
  115. data/share/devices/iPad6,11.yaml +1 -0
  116. data/share/devices/iPad6,12.yaml +1 -0
  117. data/share/devices/iPad6,3.yaml +1 -0
  118. data/share/devices/iPad6,4.yaml +1 -0
  119. data/share/devices/iPad6,7.yaml +1 -0
  120. data/share/devices/iPad6,8.yaml +1 -0
  121. data/share/devices/iPad7,1.yaml +1 -0
  122. data/share/devices/iPad7,11.yaml +1 -0
  123. data/share/devices/iPad7,12.yaml +1 -0
  124. data/share/devices/iPad7,2.yaml +1 -0
  125. data/share/devices/iPad7,3.yaml +1 -0
  126. data/share/devices/iPad7,4.yaml +1 -0
  127. data/share/devices/iPad7,5.yaml +1 -0
  128. data/share/devices/iPad7,6.yaml +1 -0
  129. data/share/devices/iPad8,1.yaml +1 -0
  130. data/share/devices/iPad8,10.yaml +1 -0
  131. data/share/devices/iPad8,11.yaml +1 -0
  132. data/share/devices/iPad8,12.yaml +1 -0
  133. data/share/devices/iPad8,2.yaml +1 -0
  134. data/share/devices/iPad8,3.yaml +1 -0
  135. data/share/devices/iPad8,4.yaml +1 -0
  136. data/share/devices/iPad8,5.yaml +1 -0
  137. data/share/devices/iPad8,6.yaml +1 -0
  138. data/share/devices/iPad8,7.yaml +1 -0
  139. data/share/devices/iPad8,8.yaml +1 -0
  140. data/share/devices/iPad8,9.yaml +1 -0
  141. data/share/devices/iPhone10,1.yaml +1 -0
  142. data/share/devices/iPhone10,2.yaml +1 -0
  143. data/share/devices/iPhone10,3.yaml +1 -0
  144. data/share/devices/iPhone10,4.yaml +1 -0
  145. data/share/devices/iPhone10,5.yaml +1 -0
  146. data/share/devices/iPhone10,6.yaml +1 -0
  147. data/share/devices/iPhone11,2.yaml +1 -0
  148. data/share/devices/iPhone11,4.yaml +1 -0
  149. data/share/devices/iPhone11,6.yaml +1 -0
  150. data/share/devices/iPhone11,8.yaml +1 -0
  151. data/share/devices/iPhone12,1.yaml +1 -0
  152. data/share/devices/iPhone12,3.yaml +1 -0
  153. data/share/devices/iPhone12,5.yaml +1 -0
  154. data/share/devices/iPhone12,8.yaml +1 -0
  155. data/share/devices/iPhone13,1.yaml +1 -0
  156. data/share/devices/iPhone13,2.yaml +1 -0
  157. data/share/devices/iPhone13,3.yaml +1 -0
  158. data/share/devices/iPhone13,4.yaml +1 -0
  159. data/share/devices/iPhone14,2.yaml +1 -0
  160. data/share/devices/iPhone14,3.yaml +1 -0
  161. data/share/devices/iPhone14,4.yaml +1 -0
  162. data/share/devices/iPhone14,5.yaml +1 -0
  163. data/share/devices/iPhone14,6.yaml +1 -0
  164. data/share/devices/iPhone6,1.yaml +1 -0
  165. data/share/devices/iPhone6,2.yaml +1 -0
  166. data/share/devices/iPhone7,1.yaml +1 -0
  167. data/share/devices/iPhone7,2.yaml +1 -0
  168. data/share/devices/iPhone8,1.yaml +1 -0
  169. data/share/devices/iPhone8,2.yaml +1 -0
  170. data/share/devices/iPhone8,4.yaml +1 -0
  171. data/share/devices/iPhone9,1.yaml +1 -0
  172. data/share/devices/iPhone9,2.yaml +1 -0
  173. data/share/devices/iPhone9,3.yaml +1 -0
  174. data/share/devices/iPhone9,4.yaml +1 -0
  175. data/share/devices/iPod7,1.yaml +1 -0
  176. data/share/devices/iPod9,1.yaml +1 -0
  177. data/share/devices/iProd99,1.yaml +1 -0
  178. data/share/dnssd.yaml +3 -3
  179. data/share/entitlements.yaml +1439 -1439
  180. data/share/environment_variables.yaml +24 -24
  181. data/share/esim.yaml +1 -0
  182. data/share/fdr.yaml +79 -48
  183. data/share/firmware.yaml +115 -115
  184. data/share/homekit.yaml +1 -1
  185. data/share/icloud.yaml +5 -1
  186. data/share/img4.yaml +461 -112
  187. data/share/ioreg.yaml +624 -624
  188. data/share/ipsw.yaml +135872 -123623
  189. data/share/kext.yaml +1910 -1906
  190. data/share/keybags/7000.yaml +1 -0
  191. data/share/keybags/7001.yaml +1 -0
  192. data/share/keybags/7002.yaml +1 -0
  193. data/share/keybags/8000.yaml +1 -0
  194. data/share/keybags/8001.yaml +1 -0
  195. data/share/keybags/8004.yaml +1 -0
  196. data/share/keybags/8006.yaml +1 -0
  197. data/share/keybags/8010.yaml +1 -0
  198. data/share/keybags/8011.yaml +1 -0
  199. data/share/keybags/8012.yaml +1 -0
  200. data/share/keybags/8015.yaml +1 -0
  201. data/share/keybags/8020.yaml +1 -0
  202. data/share/keybags/8027.yaml +1 -0
  203. data/share/keybags/8030.yaml +1 -0
  204. data/share/keybags/8101.yaml +1 -0
  205. data/share/keybags/8103.yaml +1 -0
  206. data/share/keybags/8110.yaml +1 -0
  207. data/share/keybags/8112.yaml +1 -0
  208. data/share/keybags/8120.yaml +1 -0
  209. data/share/keybags/8301.yaml +1 -0
  210. data/share/keybags/8720.yaml +1 -0
  211. data/share/keybags/8900.yaml +1 -0
  212. data/share/keybags/8920.yaml +1 -0
  213. data/share/keybags/8922.yaml +1 -0
  214. data/share/keybags/8930.yaml +1 -146
  215. data/share/keybags/8940.yaml +1 -0
  216. data/share/keybags/8942.yaml +1 -0
  217. data/share/keybags/8945.yaml +1 -0
  218. data/share/keybags/8947.yaml +1 -0
  219. data/share/keybags/8950.yaml +1 -0
  220. data/share/keybags/8955.yaml +1 -0
  221. data/share/keybags/8960.yaml +1 -0
  222. data/share/keys.yaml +4 -1
  223. data/share/launchd/services_bridgeOS_6.1.yaml +1 -0
  224. data/share/lightning.yaml +2 -0
  225. data/share/local_policy.yaml +7 -0
  226. data/share/lockdownd.yaml +125 -120
  227. data/share/mobile_assets.yaml +1 -0
  228. data/share/mobile_gestalt.yaml +708 -708
  229. data/share/nvram.yaml +81 -81
  230. data/share/ota.yaml +4 -1
  231. data/share/pallas.yaml +1 -0
  232. data/share/pki.yaml +38 -2
  233. data/share/platforms.yaml +12 -10
  234. data/share/registers.yaml +2242 -2237
  235. data/share/resources.yaml +1 -0
  236. data/share/sandbox.yaml +1 -0
  237. data/share/sep.yaml +46 -44
  238. data/share/services.yaml +119 -119
  239. data/share/sip.yaml +39 -5
  240. data/share/smc.yaml +1 -0
  241. data/share/storage.yaml +1 -1
  242. data/share/syscfg.yaml +18 -18
  243. data/share/terms.yaml +310 -310
  244. data/share/tipw_sync.yaml +171669 -6140
  245. data/share/usbpd.yaml +1 -0
  246. data/share/uuid.yaml +1 -0
  247. data/share/vmapple.yaml +1 -0
  248. metadata +6 -10
  249. data/lib/apple_data/boot_args.rb +0 -5
  250. data/lib/apple_data/fdr.rb +0 -30
  251. data/lib/apple_data/ioreg.rb +0 -59
  252. data/lib/apple_data/macho.rb +0 -7
data/share/registers.yaml CHANGED
@@ -3,2244 +3,12 @@ metadata:
3
3
  description: Representations of registers and instructions for various CPU elements
4
4
  credits:
5
5
  - https://gist.github.com/bazad/42054285391c6e0dcd0ede4b5f969ad2
6
+ collections:
7
+ - aarch64
8
+ sort_paths:
9
+ - "$.aarch64.msr"
10
+ - "$.aarch64.apple_system_registers"
6
11
  aarch64:
7
- pstate:
8
- 3: UAO
9
- 4: PAN
10
- 5: SPSel
11
- 6: DAIFSet
12
- 7: DAIFClr
13
- msr:
14
- tpidr_el1:
15
- name: TPIDR_EL1
16
- description: Thread ID, Privileged
17
- ttbr1_el1:
18
- name: TTBR1_EL1
19
- description: Translation Table Base Register 1
20
- ttbr0_el1:
21
- name: TTBR0_EL1
22
- description: Translation Table Base Register 0
23
- mpidr_el1:
24
- name: MPIDR_EL1
25
- description: MultiProcessor Affinity Register
26
- clidr_el1:
27
- name: CLIDR_EL1
28
- description: Cache Level ID Register
29
- csselr_el1:
30
- name: CSSELR_EL1
31
- description: Cache Size Selection Register
32
- sctlr_el1:
33
- name: SCTLR_EL1
34
- description: System Control Register
35
- actlr_el1:
36
- name: ACTLR_EL1
37
- description: Auxiliary Control Register
38
- cpacr_el1:
39
- name: CPACR_EL1
40
- description: Coprocessor Access Control
41
- zcr_el1:
42
- name: ZCR_EL1
43
- description: SVE Control
44
- tcr_el1:
45
- name: TCR_EL1
46
- description: Translation Control Register
47
- tcr2_el1:
48
- name: TCL2_EL1
49
- description: Extended Translation Control Register
50
- esr_el1:
51
- name: ESL_EL1
52
- description: Exception Syndrome Register
53
- afsr0_el1:
54
- name: AFSR0_EL1
55
- description: Auxiliary Fault Status Register 0
56
- afsr1_el1:
57
- name: AFSR1_EL1
58
- description: Auxiliary Fault Status Register 1
59
- far_el1:
60
- name: FAR_EL1
61
- description: Fault Address Register
62
- mair_el1:
63
- name: MAIR_EL1
64
- description: Memory Attribute Indirection Register
65
- vbar_el1:
66
- name: VBAR_EL1
67
- description: Vector Base Address Register
68
- contextidr_el1:
69
- name: CONTEXTIDR_EL1
70
- description: Context ID Register
71
- tpidr_el0:
72
- name: TPIDR_EL0
73
- description: Thread ID, User R/W
74
- S1_0_c7_c1_0:
75
- name: IC IALLUIS
76
- description: Instruction Cache Invalidate All to PoU, Inner Shareable
77
- S1_0_c7_c5_0:
78
- name: IC IALLU
79
- description: Instruction Cache Invalidate All to PoU
80
- S1_0_c7_c6_1:
81
- name: DC IVAC
82
- description: Data or unified Cache line Invalidate by VA to PoC
83
- S1_0_c7_c6_2:
84
- name: DC ISW
85
- description: Data or unified Cache line Invalidate by Set/Way
86
- S1_0_c7_c6_3:
87
- name: DC IGVAC
88
- description: Data, Allocation Tag or unified Cache line Invalidate of Allocation
89
- Tags by VA to PoC
90
- S1_0_c7_c6_4:
91
- name: DC IGSW
92
- description: Data, Allocation Tag or unified Cache line Invalidate of Allocation
93
- Tags by Set/Way
94
- S1_0_c7_c6_5:
95
- name: DC IGDVAC
96
- description: Data, Allocation Tag or unified Cache line Invalidate of Allocation
97
- Tags by VA to PoC
98
- S1_0_c7_c6_6:
99
- name: DC IGDSW
100
- description: Data, Allocation Tag or unified Cache line Invalidate of Data and
101
- Allocation Tags by Set/Way
102
- S1_0_c7_c8_0:
103
- name: AT S1E1R
104
- description: Address Translate Stage 1 EL1 Read
105
- S1_0_c7_c8_1:
106
- name: AT S1E1W
107
- description: Address Translate Stage 1 EL1 Write
108
- S1_0_c7_c8_2:
109
- name: AT S1E0R
110
- description: Address Translate Stage 1 EL0 Read
111
- S1_0_c7_c8_3:
112
- name: AT S1E0W
113
- description: Address Translate Stage 1 EL0 Write
114
- S1_0_c7_c9_0:
115
- name: AT S1E1RP
116
- description: Address Translate Stage 1 EL1 Read PAN
117
- S1_0_c7_c9_1:
118
- name: AT S1E1WP
119
- description: Address Translate Stage 1 EL1 Write PAN
120
- S1_0_c7_c10_2:
121
- name: DC CSW
122
- description: Data or unified Cache line Clean by Set/Way
123
- S1_0_c7_c10_4:
124
- name: DC CGSW
125
- description: Data, Allocation Tag or unified Cache line Clean of Allocation
126
- Tags by Set/Way
127
- S1_0_c7_c10_6:
128
- name: DC CGDSW
129
- description: Data, Allocation Tag or unified Cache line Clean of Data and Allocation
130
- Tags by Set/Way
131
- S1_0_c7_c14_2:
132
- name: DC CISW
133
- description: Data or unified Cache line Clean and Invalidate by Set/Way
134
- S1_0_c7_c14_4:
135
- name: DC CIGSW
136
- description: Data, Allocation Tag or unified Cache line Clean and Invalidate
137
- of Allocation Tags by Set/Way
138
- S1_0_c7_c14_6:
139
- name: DC CIGDSW
140
- description: Data, Allocation Tag or unified Cache line Clean and Invalidate
141
- of Data and Allocation Tags by Set/Way
142
- S1_0_c8_c1_0:
143
- name: TLBI VMALLE1OS
144
- description: TLB Invalidate by VMID, All at stage 1, EL1, Outer Shareable
145
- S1_0_c8_c1_1:
146
- name: TLBI VAE1OS
147
- description: TLB Invalidate by VA, EL1, Outer Shareable
148
- S1_0_c8_c1_2:
149
- name: TLBI ASIDE1OS
150
- description: TLB Invalidate by ASID, EL1, Outer Shareable
151
- S1_0_c8_c1_3:
152
- name: TLBI VAAE1OS
153
- description: TLB Invalidate by VA, All ASID, EL1, Outer Shareable
154
- S1_0_c8_c1_5:
155
- name: TLBI VALE1OS
156
- description: TLB Invalidate by VA, Last level, EL1, Outer Shareable
157
- S1_0_c8_c1_7:
158
- name: TLBI VAALE1OS
159
- description: TLB Invalidate by VA, All ASID, Last Level, EL1, Outer Shareable
160
- S1_0_c8_c2_1:
161
- name: TLBI RVAE1IS
162
- description: TLB Range Invalidate by VA, EL1, Inner Shareable
163
- S1_0_c8_c2_3:
164
- name: TLBI RVAAE1IS
165
- description: TLB Range Invalidate by VA, All ASID, EL1, Inner Shareable
166
- S1_0_c8_c2_5:
167
- name: TLBI RVALE1IS
168
- description: TLB Range Invalidate by VA, Last level, EL1, Inner Shareable
169
- S1_0_c8_c2_7:
170
- name: TLBI RVAALE1IS
171
- description: TLB Range Invalidate by VA, All ASID, Last Level, EL1, Inner Shareable
172
- S1_0_c8_c3_0:
173
- name: TLBI VMALLE1IS
174
- description: TLB Invalidate by VMID, All at stage 1, EL1, Inner Shareable
175
- S1_0_c8_c3_1:
176
- name: TLBI VAE1IS
177
- description: TLB Invalidate by VA, EL1, Inner Shareable
178
- S1_0_c8_c3_2:
179
- name: TLBI ASIDE1IS
180
- description: TLB Invalidate by ASID, EL1, Inner Shareable
181
- S1_0_c8_c3_3:
182
- name: TLBI VAAE1IS
183
- description: TLB Invalidate by VA, All ASID, EL1, Inner Shareable
184
- S1_0_c8_c3_5:
185
- name: TLBI VALE1IS
186
- description: TLB Invalidate by VA, Last level, EL1, Inner Shareable
187
- S1_0_c8_c3_7:
188
- name: TLBI VAALE1IS
189
- description: TLB Invalidate by VA, All ASID, Last Level, EL1, Inner Shareable
190
- S1_0_c8_c5_1:
191
- name: TLBI RVAE1OS
192
- description: TLB Range Invalidate by VA, EL1, Outer Shareable
193
- S1_0_c8_c5_3:
194
- name: TLBI RVAAE1OS
195
- description: TLB Range Invalidate by VA, All ASID, EL1, Outer Shareable
196
- S1_0_c8_c5_5:
197
- name: TLBI RVALE1OS
198
- description: TLB Range Invalidate by VA, Last level, EL1, Outer Shareable
199
- S1_0_c8_c5_7:
200
- name: TLBI RVAALE1OS
201
- description: TLB Range Invalidate by VA, All ASID, Last Level, EL1, Outer Shareable
202
- S1_0_c8_c6_1:
203
- name: TLBI RVAE1
204
- description: TLB Range Invalidate by VA, EL1
205
- S1_0_c8_c6_3:
206
- name: TLBI RVAAE1
207
- description: TLB Range Invalidate by VA, All ASID, EL1
208
- S1_0_c8_c6_5:
209
- name: TLBI RVALE1
210
- description: TLB Range Invalidate by VA, Last level, EL1
211
- S1_0_c8_c6_7:
212
- name: TLBI RVAALE1
213
- description: TLB Range Invalidate by VA, All ASID, Last level, EL1
214
- S1_0_c8_c7_0:
215
- name: TLBI VMALLE1
216
- description: TLB Invalidate by VMID, All at stage 1, EL1
217
- S1_0_c8_c7_1:
218
- name: TLBI VAE1
219
- description: TLB Invalidate by VA, EL1
220
- S1_0_c8_c7_2:
221
- name: TLBI ASIDE1
222
- description: TLB Invalidate by ASID, EL1
223
- S1_0_c8_c7_3:
224
- name: TLBI VAAE1
225
- description: TLB Invalidate by VA, All ASID, EL1
226
- S1_0_c8_c7_5:
227
- name: TLBI VALE1
228
- description: TLB Invalidate by VA, Last level, EL1
229
- S1_0_c8_c7_7:
230
- name: TLBI VAALE1
231
- description: TLB Invalidate by VA, All ASID, Last level, EL1
232
- S1_3_c7_c3_4:
233
- name: CFP RCTX
234
- description: Control Flow Prediction Restriction by Context
235
- S1_3_c7_c3_5:
236
- name: DVP RCTX
237
- description: Data Value Prediction Restriction by Context
238
- S1_3_c7_c3_7:
239
- name: CPP RCTX
240
- description: Cache Prefetch Prediction Restriction by Context
241
- S1_3_c7_c4_1:
242
- name: DC ZVA
243
- description: Data Cache Zero by VA
244
- S1_3_c7_c4_3:
245
- name: DC GVA
246
- description: Data Cache set Allocation Tag by VA
247
- S1_3_c7_c4_4:
248
- name: DC GZVA
249
- description: Data Cache set Allocation Tags and Zero by VA
250
- S1_3_c7_c5_1:
251
- name: IC IVAU
252
- description: Instruction Cache line Invalidate by VA to PoU
253
- S1_3_c7_c10_1:
254
- name: DC CVAC
255
- description: Data or unified Cache line Clean by VA to PoC
256
- S1_3_c7_c10_3:
257
- name: DC CGVAC
258
- description: Data, Allocation Tag or unified Cache line Clean of Allocation
259
- Tags by VA to PoC
260
- S1_3_c7_c10_5:
261
- name: DC CGDVAC
262
- description: Data, Allocation Tag or unified Cache line Clean of Allocation
263
- Tags by VA to PoC
264
- S1_3_c7_c11_1:
265
- name: DC CVAU
266
- description: Data or unified Cache line Clean by VA to PoU
267
- S1_3_c7_c12_1:
268
- name: DC CVAP
269
- description: Data or unified Cache line Clean by VA to PoP
270
- S1_3_c7_c12_3:
271
- name: DC CGVAP
272
- description: Data, Allocation Tag or unified Cache line Clean of Allocation
273
- Tags by VA to PoP
274
- S1_3_c7_c12_5:
275
- name: DC CGDVAP
276
- description: Data, Allocation Tag or unified Cache line Clean of Data and Allocation
277
- Tags by VA to PoP
278
- S1_3_c7_c13_1:
279
- name: DC CVADP
280
- description: Data or unified Cache line Clean by VA to PoDP
281
- S1_3_c7_c13_3:
282
- name: DC CGVADP
283
- description: Clean of Allocation Tags by VA to PoDP
284
- S1_3_c7_c13_5:
285
- name: DC CGDVADP
286
- description: Data, Allocation Tag or unified Cache line Clean of Allocation
287
- Tags by VA to PoDP
288
- S1_3_c7_c14_1:
289
- name: DC CIVAC
290
- description: Data or unified Cache line Clean and Invalidate by VA to PoC
291
- S1_3_c7_c14_3:
292
- name: DC CIGVAC
293
- description: Data, Allocation Tag or unified Cache line Clean and Invalidate
294
- of Allocation Tags by VA to PoC
295
- S1_3_c7_c14_5:
296
- name: DC CIGDVAC
297
- description: Data, Allocation Tag or unified Cache line Clean and Invalidate
298
- of Data and Allocation Tags by VA to PoC
299
- S1_4_c7_c8_0:
300
- name: AT S1E2R
301
- description: Address Translate Stage 1 EL2 Read
302
- S1_4_c7_c8_1:
303
- name: AT S1E2W
304
- description: Address Translate Stage 1 EL2 Write
305
- S1_4_c7_c8_4:
306
- name: AT S12E1R
307
- description: Address Translate Stages 1 and 2 EL1 Read
308
- S1_4_c7_c8_5:
309
- name: AT S12E1W
310
- description: Address Translate Stages 1 and 2 EL1 Write
311
- S1_4_c7_c8_6:
312
- name: AT S12E0R
313
- description: Address Translate Stages 1 and 2 EL0 Read
314
- S1_4_c7_c8_7:
315
- name: AT S12E0W
316
- description: Address Translate Stages 1 and 2 EL0 Write
317
- S1_4_c8_c0_1:
318
- name: TLBI IPAS2E1IS
319
- description: TLB Invalidate by Intermediate Physical Address, Stage 2, EL1,
320
- Inner Shareable
321
- S1_4_c8_c0_2:
322
- name: TLBI RIPAS2E1IS
323
- description: TLB Range Invalidate by Intermediate Physical Address, Stage 2,
324
- EL1, Inner Shareable
325
- S1_4_c8_c0_5:
326
- name: TLBI IPAS2LE1IS
327
- description: TLB Invalidate by Intermediate Physical Address, Stage 2, Last
328
- level, EL1, Inner Shareable
329
- S1_4_c8_c0_6:
330
- name: TLBI RIPAS2LE1IS
331
- description: TLB Range Invalidate by Intermediate Physical Address, Stage 2,
332
- Last level, EL1, Inner Shareable
333
- S1_4_c8_c1_0:
334
- name: TLBI ALLE2OS
335
- description: TLB Invalidate All, EL2, Outer Shareable
336
- S1_4_c8_c1_1:
337
- name: TLBI VAE2OS
338
- description: TLB Invalidate by VA, EL2, Outer Shareable
339
- S1_4_c8_c1_4:
340
- name: TLBI ALLE1OS
341
- description: TLB Invalidate All, EL1, Outer Shareable
342
- S1_4_c8_c1_5:
343
- name: TLBI VALE2OS
344
- description: TLB Invalidate by VA, Last level, EL2, Outer Shareable
345
- S1_4_c8_c1_6:
346
- name: TLBI VMALLS12E1OS
347
- description: TLB Invalidate by VMID, All at Stage 1 and 2, EL1, Outer Shareable
348
- S1_4_c8_c2_1:
349
- name: TLBI RVAE2IS
350
- description: TLB Range Invalidate by VA, EL2, Inner Shareable
351
- S1_4_c8_c2_5:
352
- name: TLBI RVALE2IS
353
- description: TLB Range Invalidate by VA, Last level, EL2, Inner Shareable
354
- S1_4_c8_c3_0:
355
- name: TLBI ALLE2IS
356
- description: TLB Invalidate All, EL2, Inner Shareable
357
- S1_4_c8_c3_1:
358
- name: TLBI VAE2IS
359
- description: TLB Invalidate by VA, EL2, Inner Shareable
360
- S1_4_c8_c3_4:
361
- name: TLBI ALLE1IS
362
- description: TLB Invalidate All, EL1, Inner Shareable
363
- S1_4_c8_c3_5:
364
- name: TLBI VALE2IS
365
- description: TLB Invalidate by VA, Last level, EL2, Inner Shareable
366
- S1_4_c8_c3_6:
367
- name: TLBI VMALLS12E1IS
368
- description: TLB Invalidate by VMID, All at Stage 1 and 2, EL1, Inner Shareable
369
- S1_4_c8_c4_0:
370
- name: TLBI IPAS2E1OS
371
- description: TLB Invalidate by Intermediate Physical Address, Stage 2, EL1,
372
- Outer Shareable
373
- S1_4_c8_c4_1:
374
- name: TLBI IPAS2E1
375
- description: TLB Invalidate by Intermediate Physical Address, Stage 2, EL1
376
- S1_4_c8_c4_2:
377
- name: TLBI RIPAS2E1
378
- description: TLB Range Invalidate by Intermediate Physical Address, Stage 2,
379
- EL1
380
- S1_4_c8_c4_3:
381
- name: TLBI RIPAS2E1OS
382
- description: TLB Range Invalidate by Intermediate Physical Address, Stage 2,
383
- EL1, Outer Shareable
384
- S1_4_c8_c4_4:
385
- name: TLBI IPAS2LE1OS
386
- description: TLB Invalidate by Intermediate Physical Address, Stage 2, Last
387
- level, EL1, Outer Shareable
388
- S1_4_c8_c4_5:
389
- name: TLBI IPAS2LE1
390
- description: TLB Invalidate by Intermediate Physical Address, Stage 2, Last
391
- level, EL1
392
- S1_4_c8_c4_6:
393
- name: TLBI RIPAS2LE1
394
- description: TLB Range Invalidate by Intermediate Physical Address, Stage 2,
395
- Last level, EL1
396
- S1_4_c8_c4_7:
397
- name: TLBI RIPAS2LE1OS
398
- description: TLB Range Invalidate by Intermediate Physical Address, Stage 2,
399
- Last level, EL1, Outer Shareable
400
- S1_4_c8_c5_1:
401
- name: TLBI RVAE2OS
402
- description: TLB Range Invalidate by VA, EL2, Outer Shareable
403
- S1_4_c8_c5_5:
404
- name: TLBI RVALE2OS
405
- description: TLB Range Invalidate by VA, Last level, EL2, Outer Shareable
406
- S1_4_c8_c6_1:
407
- name: TLBI RVAE2
408
- description: TLB Range Invalidate by VA, EL2
409
- S1_4_c8_c6_5:
410
- name: TLBI RVALE2
411
- description: TLB Range Invalidate by VA, Last level, EL2
412
- S1_4_c8_c7_0:
413
- name: TLBI ALLE2
414
- description: TLB Invalidate All, EL2
415
- S1_4_c8_c7_1:
416
- name: TLBI VAE2
417
- description: TLB Invalidate by VA, EL2
418
- S1_4_c8_c7_4:
419
- name: TLBI ALLE1
420
- description: TLB Invalidate All, EL1
421
- S1_4_c8_c7_5:
422
- name: TLBI VALE2
423
- description: TLB Invalidate by VA, Last level, EL2
424
- S1_4_c8_c7_6:
425
- name: TLBI VMALLS12E1
426
- description: TLB Invalidate by VMID, All at Stage 1 and 2, EL1
427
- S1_6_c7_c8_0:
428
- name: AT S1E3R
429
- description: Address Translate Stage 1 EL3 Read
430
- S1_6_c7_c8_1:
431
- name: AT S1E3W
432
- description: Address Translate Stage 1 EL3 Write
433
- S1_6_c8_c1_0:
434
- name: TLBI ALLE3OS
435
- description: TLB Invalidate All, EL3, Outer Shareable
436
- S1_6_c8_c1_1:
437
- name: TLBI VAE3OS
438
- description: TLB Invalidate by VA, EL3, Outer Shareable
439
- S1_6_c8_c1_5:
440
- name: TLBI VALE3OS
441
- description: TLB Invalidate by VA, Last level, EL3, Outer Shareable
442
- S1_6_c8_c2_1:
443
- name: TLBI RVAE3IS
444
- description: TLB Range Invalidate by VA, EL3, Inner Shareable
445
- S1_6_c8_c2_5:
446
- name: TLBI RVALE3IS
447
- description: TLB Range Invalidate by VA, Last level, EL3, Inner Shareable
448
- S1_6_c8_c3_0:
449
- name: TLBI ALLE3IS
450
- description: TLB Invalidate All, EL3, Inner Shareable
451
- S1_6_c8_c3_1:
452
- name: TLBI VAE3IS
453
- description: TLB Invalidate by VA, EL3, Inner Shareable
454
- S1_6_c8_c3_5:
455
- name: TLBI VALE3IS
456
- description: TLB Invalidate by VA, Last level, EL3, Inner Shareable
457
- S1_6_c8_c5_1:
458
- name: TLBI RVAE3OS
459
- description: TLB Range Invalidate by VA, EL3, Outer Shareable
460
- S1_6_c8_c5_5:
461
- name: TLBI RVALE3OS
462
- description: TLB Range Invalidate by VA, Last level, EL3, Outer Shareable
463
- S1_6_c8_c6_1:
464
- name: TLBI RVAE3
465
- description: TLB Range Invalidate by VA, EL3
466
- S1_6_c8_c6_5:
467
- name: TLBI RVALE3
468
- description: TLB Range Invalidate by VA, Last level, EL3
469
- S1_6_c8_c7_0:
470
- name: TLBI ALLE3
471
- description: TLB Invalidate All, EL3
472
- S1_6_c8_c7_1:
473
- name: TLBI VAE3
474
- description: TLB Invalidate by VA, EL3
475
- S1_6_c8_c7_5:
476
- name: TLBI VALE3
477
- description: TLB Invalidate by VA, Last level, EL3
478
- S2_0_c0_c0_2:
479
- name: OSDTRRX_EL1
480
- description: OS Lock Data Transfer Register, Receive
481
- S2_0_c0_c0_4:
482
- name: DBGBVR0_EL1
483
- description: Debug Breakpoint Value Register 0
484
- S2_0_c0_c0_5:
485
- name: DBGBCR0_EL1
486
- description: Debug Breakpoint Control Register 0
487
- S2_0_c0_c0_6:
488
- name: DBGWVR0_EL1
489
- description: Debug Watchpoint Value Register 0
490
- S2_0_c0_c0_7:
491
- name: DBGWCR0_EL1
492
- description: Debug Watchpoint Control Register 0
493
- S2_0_c0_c1_4:
494
- name: DBGBVR1_EL1
495
- description: Debug Breakpoint Value Register 1
496
- S2_0_c0_c1_5:
497
- name: DBGBCR1_EL1
498
- description: Debug Breakpoint Control Register 1
499
- S2_0_c0_c1_6:
500
- name: DBGWVR1_EL1
501
- description: Debug Watchpoint Value Register 1
502
- S2_0_c0_c1_7:
503
- name: DBGWCR1_EL1
504
- description: Debug Watchpoint Control Register 1
505
- S2_0_c0_c2_0:
506
- name: MDCCINT_EL1
507
- description: Monitor DCC Interrupt Enable Register
508
- S2_0_c0_c2_2:
509
- name: MDSCR_EL1
510
- description: Monitor Debug System Control Register
511
- S2_0_c0_c2_4:
512
- name: DBGBVR2_EL1
513
- description: Debug Breakpoint Value Register 2
514
- S2_0_c0_c2_5:
515
- name: DBGBCR2_EL1
516
- description: Debug Breakpoint Control Register 2
517
- S2_0_c0_c2_6:
518
- name: DBGWVR2_EL1
519
- description: Debug Watchpoint Value Register 2
520
- S2_0_c0_c2_7:
521
- name: DBGWCR2_EL1
522
- description: Debug Watchpoint Control Register 2
523
- S2_0_c0_c3_2:
524
- name: OSDTRTX_EL1
525
- description: OS Lock Data Transfer Register, Transmit
526
- S2_0_c0_c3_4:
527
- name: DBGBVR3_EL1
528
- description: Debug Breakpoint Value Register 3
529
- S2_0_c0_c3_5:
530
- name: DBGBCR3_EL1
531
- description: Debug Breakpoint Control Register 3
532
- S2_0_c0_c3_6:
533
- name: DBGWVR3_EL1
534
- description: Debug Watchpoint Value Register 3
535
- S2_0_c0_c3_7:
536
- name: DBGWCR3_EL1
537
- description: Debug Watchpoint Control Register 3
538
- S2_0_c0_c4_4:
539
- name: DBGBVR4_EL1
540
- description: Debug Breakpoint Value Register 4
541
- S2_0_c0_c4_5:
542
- name: DBGBCR4_EL1
543
- description: Debug Breakpoint Control Register 4
544
- S2_0_c0_c4_6:
545
- name: DBGWVR4_EL1
546
- description: Debug Watchpoint Value Register 4
547
- S2_0_c0_c4_7:
548
- name: DBGWCR4_EL1
549
- description: Debug Watchpoint Control Register 4
550
- S2_0_c0_c5_4:
551
- name: DBGBVR5_EL1
552
- description: Debug Breakpoint Value Register 5
553
- S2_0_c0_c5_5:
554
- name: DBGBCR5_EL1
555
- description: Debug Breakpoint Control Register 5
556
- S2_0_c0_c5_6:
557
- name: DBGWVR5_EL1
558
- description: Debug Watchpoint Value Register 5
559
- S2_0_c0_c5_7:
560
- name: DBGWCR5_EL1
561
- description: Debug Watchpoint Control Register 5
562
- S2_0_c0_c6_2:
563
- name: OSECCR_EL1
564
- description: OS Lock Exception Catch Control Register
565
- S2_0_c0_c6_4:
566
- name: DBGBVR6_EL1
567
- description: Debug Breakpoint Value Register 6
568
- S2_0_c0_c6_5:
569
- name: DBGBCR6_EL1
570
- description: Debug Breakpoint Control Register 6
571
- S2_0_c0_c6_6:
572
- name: DBGWVR6_EL1
573
- description: Debug Watchpoint Value Register 6
574
- S2_0_c0_c6_7:
575
- name: DBGWCR6_EL1
576
- description: Debug Watchpoint Control Register 6
577
- S2_0_c0_c7_4:
578
- name: DBGBVR7_EL1
579
- description: Debug Breakpoint Value Register 7
580
- S2_0_c0_c7_5:
581
- name: DBGBCR7_EL1
582
- description: Debug Breakpoint Control Register 7
583
- S2_0_c0_c7_6:
584
- name: DBGWVR7_EL1
585
- description: Debug Watchpoint Value Register 7
586
- S2_0_c0_c7_7:
587
- name: DBGWCR7_EL1
588
- description: Debug Watchpoint Control Register 7
589
- S2_0_c0_c8_4:
590
- name: DBGBVR8_EL1
591
- description: Debug Breakpoint Value Register 8
592
- S2_0_c0_c8_5:
593
- name: DBGBCR8_EL1
594
- description: Debug Breakpoint Control Register 8
595
- S2_0_c0_c8_6:
596
- name: DBGWVR8_EL1
597
- description: Debug Watchpoint Value Register 8
598
- S2_0_c0_c8_7:
599
- name: DBGWCR8_EL1
600
- description: Debug Watchpoint Control Register 8
601
- S2_0_c0_c9_4:
602
- name: DBGBVR9_EL1
603
- description: Debug Breakpoint Value Register 9
604
- S2_0_c0_c9_5:
605
- name: DBGBCR9_EL1
606
- description: Debug Breakpoint Control Register 9
607
- S2_0_c0_c9_6:
608
- name: DBGWVR9_EL1
609
- description: Debug Watchpoint Value Register 9
610
- S2_0_c0_c9_7:
611
- name: DBGWCR9_EL1
612
- description: Debug Watchpoint Control Register 9
613
- S2_0_c0_c10_4:
614
- name: DBGBVR10_EL1
615
- description: Debug Breakpoint Value Register 10
616
- S2_0_c0_c10_5:
617
- name: DBGBCR10_EL1
618
- description: Debug Breakpoint Control Register 10
619
- S2_0_c0_c10_6:
620
- name: DBGWVR10_EL1
621
- description: Debug Watchpoint Value Register 10
622
- S2_0_c0_c10_7:
623
- name: DBGWCR10_EL1
624
- description: Debug Watchpoint Control Register 10
625
- S2_0_c0_c11_4:
626
- name: DBGBVR11_EL1
627
- description: Debug Breakpoint Value Register 11
628
- S2_0_c0_c11_5:
629
- name: DBGBCR11_EL1
630
- description: Debug Breakpoint Control Register 11
631
- S2_0_c0_c11_6:
632
- name: DBGWVR11_EL1
633
- description: Debug Watchpoint Value Register 11
634
- S2_0_c0_c11_7:
635
- name: DBGWCR11_EL1
636
- description: Debug Watchpoint Control Register 11
637
- S2_0_c0_c12_4:
638
- name: DBGBVR12_EL1
639
- description: Debug Breakpoint Value Register 12
640
- S2_0_c0_c12_5:
641
- name: DBGBCR12_EL1
642
- description: Debug Breakpoint Control Register 12
643
- S2_0_c0_c12_6:
644
- name: DBGWVR12_EL1
645
- description: Debug Watchpoint Value Register 12
646
- S2_0_c0_c12_7:
647
- name: DBGWCR12_EL1
648
- description: Debug Watchpoint Control Register 12
649
- S2_0_c0_c13_4:
650
- name: DBGBVR13_EL1
651
- description: Debug Breakpoint Value Register 13
652
- S2_0_c0_c13_5:
653
- name: DBGBCR13_EL1
654
- description: Debug Breakpoint Control Register 13
655
- S2_0_c0_c13_6:
656
- name: DBGWVR13_EL1
657
- description: Debug Watchpoint Value Register 13
658
- S2_0_c0_c13_7:
659
- name: DBGWCR13_EL1
660
- description: Debug Watchpoint Control Register 13
661
- S2_0_c0_c14_4:
662
- name: DBGBVR14_EL1
663
- description: Debug Breakpoint Value Register 14
664
- S2_0_c0_c14_5:
665
- name: DBGBCR14_EL1
666
- description: Debug Breakpoint Control Register 14
667
- S2_0_c0_c14_6:
668
- name: DBGWVR14_EL1
669
- description: Debug Watchpoint Value Register 14
670
- S2_0_c0_c14_7:
671
- name: DBGWCR14_EL1
672
- description: Debug Watchpoint Control Register 14
673
- S2_0_c0_c15_4:
674
- name: DBGBVR15_EL1
675
- description: Debug Breakpoint Value Register 15
676
- S2_0_c0_c15_5:
677
- name: DBGBCR15_EL1
678
- description: Debug Breakpoint Control Register 15
679
- S2_0_c0_c15_6:
680
- name: DBGWVR15_EL1
681
- description: Debug Watchpoint Value Register 15
682
- S2_0_c0_c15_7:
683
- name: DBGWCR15_EL1
684
- description: Debug Watchpoint Control Register 15
685
- S2_0_c1_c0_0:
686
- name: MDRAR_EL1
687
- description: Monitor Debug ROM Address Register
688
- S2_0_c1_c0_4:
689
- name: OSLAR_EL1
690
- description: OS Lock Access Register
691
- S2_0_c1_c1_4:
692
- name: OSLSR_EL1
693
- description: OS Lock Status Register
694
- S2_0_c1_c3_4:
695
- name: OSDLR_EL1
696
- description: OS Double Lock Register
697
- S2_0_c1_c4_4:
698
- name: DBGPRCR_EL1
699
- description: Debug Power Control Register
700
- S2_0_c7_c8_6:
701
- name: DBGCLAIMSET_EL1
702
- description: Debug CLAIM Tag Set register
703
- S2_0_c7_c9_6:
704
- name: DBGCLAIMCLR_EL1
705
- description: Debug CLAIM Tag Clear register
706
- S2_0_c7_c14_6:
707
- name: DBGAUTHSTATUS_EL1
708
- description: Debug Authentication Status register
709
- S2_3_c0_c1_0:
710
- name: MDCCSR_EL0
711
- description: Monitor DCC Status Register
712
- S2_3_c0_c4_0:
713
- name: DBGDTR_EL0
714
- description: Debug Data Transfer Register, half-duplex
715
- S2_3_c0_c5_0:
716
- name: DBGDTRRX_EL0
717
- description: Debug Data Transfer Register
718
- S2_4_c0_c7_0:
719
- name: DBGVCR32_EL2
720
- description: Debug Vector Catch Register
721
- S3_0_c0_c0_0:
722
- name: MIDR_EL1
723
- description: Main ID Register
724
- S3_0_c0_c0_5:
725
- name: MPIDR_EL1
726
- description: Multiprocessor Affinity Register
727
- S3_0_c0_c0_6:
728
- name: REVIDR_EL1
729
- description: Revision ID Register
730
- S3_0_c0_c1_0:
731
- name: ID_PFR0_EL1
732
- description: AArch32 Processor Feature Register 0
733
- S3_0_c0_c1_1:
734
- name: ID_PFR1_EL1
735
- description: AArch32 Processor Feature Register 1
736
- S3_0_c0_c1_2:
737
- name: ID_DFR0_EL1
738
- description: AArch32 Debug Feature Register 0
739
- S3_0_c0_c1_3:
740
- name: ID_AFR0_EL1
741
- description: AArch32 Auxiliary Feature Register 0
742
- S3_0_c0_c1_4:
743
- name: ID_MMFR0_EL1
744
- description: AArch32 Memory Model Feature Register 0
745
- S3_0_c0_c1_5:
746
- name: ID_MMFR1_EL1
747
- description: AArch32 Memory Model Feature Register 1
748
- S3_0_c0_c1_6:
749
- name: ID_MMFR2_EL1
750
- description: AArch32 Memory Model Feature Register 2
751
- S3_0_c0_c1_7:
752
- name: ID_MMFR3_EL1
753
- description: AArch32 Memory Model Feature Register 3
754
- S3_0_c0_c2_0:
755
- name: ID_ISAR0_EL1
756
- description: AArch32 Instruction Set Attribute Register 0
757
- S3_0_c0_c2_1:
758
- name: ID_ISAR1_EL1
759
- description: AArch32 Instruction Set Attribute Register 1
760
- S3_0_c0_c2_2:
761
- name: ID_ISAR2_EL1
762
- description: AArch32 Instruction Set Attribute Register 2
763
- S3_0_c0_c2_3:
764
- name: ID_ISAR3_EL1
765
- description: AArch32 Instruction Set Attribute Register 3
766
- S3_0_c0_c2_4:
767
- name: ID_ISAR4_EL1
768
- description: AArch32 Instruction Set Attribute Register 4
769
- S3_0_c0_c2_5:
770
- name: ID_ISAR5_EL1
771
- description: AArch32 Instruction Set Attribute Register 5
772
- S3_0_c0_c2_6:
773
- name: ID_MMFR4_EL1
774
- description: AArch32 Memory Model Feature Register 4
775
- S3_0_c0_c2_7:
776
- name: ID_ISAR6_EL1
777
- description: AArch32 Instruction Set Attribute Register 6
778
- S3_0_c0_c3_0:
779
- name: MVFR0_EL1
780
- description: AArch32 Media and VFP Feature Register 0
781
- S3_0_c0_c3_1:
782
- name: MVFR1_EL1
783
- description: AArch32 Media and VFP Feature Register 1
784
- S3_0_c0_c3_2:
785
- name: MVFR2_EL1
786
- description: AArch32 Media and VFP Feature Register 2
787
- S3_0_c0_c3_4:
788
- name: ID_PFR2_EL1
789
- description: AArch32 Processor Feature Register 2
790
- S3_0_c0_c3_5:
791
- name: ID_DFR1_EL1
792
- description: Debug Feature Register 1
793
- S3_0_c0_c3_6:
794
- name: ID_MMFR5_EL1
795
- description: AArch32 Memory Model Feature Register 5
796
- S3_0_c0_c4_0:
797
- name: ID_AA64PFR0_EL1
798
- description: AArch64 Processor Feature Register 0
799
- S3_0_c0_c4_1:
800
- name: ID_AA64PFR1_EL1
801
- description: AArch64 Processor Feature Register 1
802
- S3_0_c0_c4_4:
803
- name: ID_AA64ZFR0_EL1
804
- description: SVE Feature ID register 0
805
- S3_0_c0_c5_0:
806
- name: ID_AA64DFR0_EL1
807
- description: AArch64 Debug Feature Register 0
808
- S3_0_c0_c5_1:
809
- name: ID_AA64DFR1_EL1
810
- description: AArch64 Debug Feature Register 1
811
- S3_0_c0_c5_4:
812
- name: ID_AA64AFR0_EL1
813
- description: AArch64 Auxiliary Feature Register 0
814
- S3_0_c0_c5_5:
815
- name: ID_AA64AFR1_EL1
816
- description: AArch64 Auxiliary Feature Register 1
817
- S3_0_c0_c6_0:
818
- name: ID_AA64ISAR0_EL1
819
- description: AArch64 Instruction Set Attribute Register 0
820
- S3_0_c0_c6_1:
821
- name: ID_AA64ISAR1_EL1
822
- description: AArch64 Instruction Set Attribute Register 1
823
- S3_0_c0_c7_0:
824
- name: ID_AA64MMFR0_EL1
825
- description: AArch64 Memory Model Feature Register 0
826
- S3_0_c0_c7_1:
827
- name: ID_AA64MMFR1_EL1
828
- description: AArch64 Memory Model Feature Register 1
829
- S3_0_c0_c7_2:
830
- name: ID_AA64MMFR2_EL1
831
- description: AArch64 Memory Model Feature Register 2
832
- S3_0_c1_c0_0:
833
- name: SCTLR_EL1
834
- description: System Control Register (EL1)
835
- S3_0_c1_c0_1:
836
- name: ACTLR_EL1
837
- description: Auxiliary Control Register (EL1)
838
- S3_0_c1_c0_2:
839
- name: CPACR_EL1
840
- description: Architectural Feature Access Control Register
841
- S3_0_c1_c0_5:
842
- name: RGSR_EL1
843
- description: Random Allocation Tag Seed Register.
844
- S3_0_c1_c0_6:
845
- name: GCR_EL1
846
- description: Tag Control Register.
847
- S3_0_c1_c2_0:
848
- name: ZCR_EL1
849
- description: SVE Control Register for EL1
850
- S3_0_c1_c2_1:
851
- name: TRFCR_EL1
852
- description: Trace Filter Control Register (EL1)
853
- S3_0_c2_c0_0:
854
- name: TTBR0_EL1
855
- description: Translation Table Base Register 0 (EL1)
856
- S3_0_c2_c0_1:
857
- name: TTBR1_EL1
858
- description: Translation Table Base Register 1 (EL1)
859
- S3_0_c2_c0_2:
860
- name: TCR_EL1
861
- description: Translation Control Register (EL1)
862
- S3_0_c2_c1_0:
863
- name: APIAKeyLo_EL1
864
- description: 'Pointer Authentication Key A for Instruction (bits[63:0]) '
865
- S3_0_c2_c1_1:
866
- name: APIAKeyHi_EL1
867
- description: 'Pointer Authentication Key A for Instruction (bits[127:64]) '
868
- S3_0_c2_c1_2:
869
- name: APIBKeyLo_EL1
870
- description: 'Pointer Authentication Key B for Instruction (bits[63:0]) '
871
- S3_0_c2_c1_3:
872
- name: APIBKeyHi_EL1
873
- description: 'Pointer Authentication Key B for Instruction (bits[127:64]) '
874
- S3_0_c2_c2_0:
875
- name: APDAKeyLo_EL1
876
- description: 'Pointer Authentication Key A for Data (bits[63:0]) '
877
- S3_0_c2_c2_1:
878
- name: APDAKeyHi_EL1
879
- description: 'Pointer Authentication Key A for Data (bits[127:64]) '
880
- S3_0_c2_c2_2:
881
- name: APDBKeyLo_EL1
882
- description: 'Pointer Authentication Key B for Data (bits[63:0]) '
883
- S3_0_c2_c2_3:
884
- name: APDBKeyHi_EL1
885
- description: 'Pointer Authentication Key B for Data (bits[127:64]) '
886
- S3_0_c2_c3_0:
887
- name: APGAKeyLo_EL1
888
- description: 'Pointer Authentication Key A for Code (bits[63:0]) '
889
- S3_0_c2_c3_1:
890
- name: APGAKeyHi_EL1
891
- description: 'Pointer Authentication Key A for Code (bits[127:64]) '
892
- S3_0_c4_c0_0:
893
- name: SPSR_EL1
894
- description: Saved Program Status Register (EL1)
895
- S3_0_c4_c0_1:
896
- name: ELR_EL1
897
- description: Exception Link Register (EL1)
898
- S3_0_c4_c1_0:
899
- name: SP_EL0
900
- description: Stack Pointer (EL0)
901
- S3_0_c4_c2_0:
902
- name: SPSel
903
- description: Stack Pointer Select
904
- S3_0_c4_c2_2:
905
- name: CurrentEL
906
- description: Current Exception Level
907
- S3_0_c4_c2_3:
908
- name: PAN
909
- description: Privileged Access Never
910
- S3_0_c4_c2_4:
911
- name: UAO
912
- description: User Access Override
913
- S3_0_c4_c6_0:
914
- name: ICC_PMR_EL1
915
- description: Interrupt Controller Interrupt Priority Mask Register Interrupt
916
- Controller Virtual Interrupt Priority Mask Register
917
- S3_0_c5_c1_0:
918
- name: AFSR0_EL1
919
- description: Auxiliary Fault Status Register 0 (EL1)
920
- S3_0_c5_c1_1:
921
- name: AFSR1_EL1
922
- description: Auxiliary Fault Status Register 1 (EL1)
923
- S3_0_c5_c2_0:
924
- name: ESR_EL1
925
- description: Exception Syndrome Register (EL1)
926
- S3_0_c5_c3_0:
927
- name: ERRIDR_EL1
928
- description: Error Record ID Register
929
- S3_0_c5_c3_1:
930
- name: ERRSELR_EL1
931
- description: Error Record Select Register
932
- S3_0_c5_c4_0:
933
- name: ERXFR_EL1
934
- description: Selected Error Record Feature Register
935
- S3_0_c5_c4_1:
936
- name: ERXCTLR_EL1
937
- description: Selected Error Record Control Register
938
- S3_0_c5_c4_2:
939
- name: ERXSTATUS_EL1
940
- description: Selected Error Record Primary Status Register
941
- S3_0_c5_c4_3:
942
- name: ERXADDR_EL1
943
- description: Selected Error Record Address Register
944
- S3_0_c5_c4_4:
945
- name: ERXPFGF_EL1
946
- description: Selected Pseudo-fault Generation Feature register
947
- S3_0_c5_c4_5:
948
- name: ERXPFGCTL_EL1
949
- description: Selected Pseudo-fault Generation Control register
950
- S3_0_c5_c4_6:
951
- name: ERXPFGCDN_EL1
952
- description: Selected Pseudo-fault Generation Countdown register
953
- S3_0_c5_c5_0:
954
- name: ERXMISC0_EL1
955
- description: Selected Error Record Miscellaneous Register 0
956
- S3_0_c5_c5_1:
957
- name: ERXMISC1_EL1
958
- description: Selected Error Record Miscellaneous Register 1
959
- S3_0_c5_c5_2:
960
- name: ERXMISC2_EL1
961
- description: Selected Error Record Miscellaneous Register 2
962
- S3_0_c5_c5_3:
963
- name: ERXMISC3_EL1
964
- description: Selected Error Record Miscellaneous Register 3
965
- S3_0_c5_c6_0:
966
- name: TFSR_EL1
967
- description: Tag Fault Status Register (EL1)
968
- S3_0_c5_c6_1:
969
- name: TFSRE0_EL1
970
- description: Tag Fault Status Register (EL0).
971
- S3_0_c6_c0_0:
972
- name: FAR_EL1
973
- description: Fault Address Register (EL1)
974
- S3_0_c7_c4_0:
975
- name: PAR_EL1
976
- description: Physical Address Register
977
- S3_0_c9_c9_0:
978
- name: PMSCR_EL1
979
- description: Statistical Profiling Control Register (EL1)
980
- S3_0_c9_c9_2:
981
- name: PMSICR_EL1
982
- description: Sampling Interval Counter Register
983
- S3_0_c9_c9_3:
984
- name: PMSIRR_EL1
985
- description: Sampling Interval Reload Register
986
- S3_0_c9_c9_4:
987
- name: PMSFCR_EL1
988
- description: Sampling Filter Control Register
989
- S3_0_c9_c9_5:
990
- name: PMSEVFR_EL1
991
- description: Sampling Event Filter Register
992
- S3_0_c9_c9_6:
993
- name: PMSLATFR_EL1
994
- description: Sampling Latency Filter Register
995
- S3_0_c9_c9_7:
996
- name: PMSIDR_EL1
997
- description: Sampling Profiling ID Register
998
- S3_0_c9_c10_0:
999
- name: PMBLIMITR_EL1
1000
- description: Profiling Buffer Limit Address Register
1001
- S3_0_c9_c10_1:
1002
- name: PMBPTR_EL1
1003
- description: Profiling Buffer Write Pointer Register
1004
- S3_0_c9_c10_3:
1005
- name: PMBSR_EL1
1006
- description: Profiling Buffer Status/syndrome Register
1007
- S3_0_c9_c10_7:
1008
- name: PMBIDR_EL1
1009
- description: Profiling Buffer ID Register
1010
- S3_0_c9_c14_1:
1011
- name: PMINTENSET_EL1
1012
- description: Performance Monitors Interrupt Enable Set register
1013
- S3_0_c9_c14_2:
1014
- name: PMINTENCLR_EL1
1015
- description: Performance Monitors Interrupt Enable Clear register
1016
- S3_0_c9_c14_6:
1017
- name: PMMIR_EL1
1018
- description: Performance Monitors Machine Identification Register
1019
- S3_0_c10_c2_0:
1020
- name: MAIR_EL1
1021
- description: Memory Attribute Indirection Register (EL1)
1022
- S3_0_c10_c3_0:
1023
- name: AMAIR_EL1
1024
- description: Auxiliary Memory Attribute Indirection Register (EL1)
1025
- S3_0_c10_c4_0:
1026
- name: LORSA_EL1
1027
- description: LORegion Start Address (EL1)
1028
- S3_0_c10_c4_1:
1029
- name: LOREA_EL1
1030
- description: LORegion End Address (EL1)
1031
- S3_0_c10_c4_2:
1032
- name: LORN_EL1
1033
- description: LORegion Number (EL1)
1034
- S3_0_c10_c4_3:
1035
- name: LORC_EL1
1036
- description: LORegion Control (EL1)
1037
- S3_0_c10_c4_4:
1038
- name: MPAMIDR_EL1
1039
- description: MPAM ID Register (EL1)
1040
- S3_0_c10_c4_7:
1041
- name: LORID_EL1
1042
- description: LORegionID (EL1)
1043
- S3_0_c10_c5_0:
1044
- name: MPAM1_EL1
1045
- description: MPAM1 Register (EL1)
1046
- S3_0_c10_c5_1:
1047
- name: MPAM0_EL1
1048
- description: MPAM0 Register (EL1)
1049
- S3_0_c12_c0_0:
1050
- name: VBAR_EL1
1051
- description: Vector Base Address Register (EL1)
1052
- S3_0_c12_c0_1:
1053
- name: RVBAR_EL1
1054
- description: Reset Vector Base Address Register (if EL2 and EL3 not implemented)
1055
- S3_0_c12_c0_2:
1056
- name: RMR_EL1
1057
- description: Reset Management Register (EL1)
1058
- S3_0_c12_c1_0:
1059
- name: ISR_EL1
1060
- description: Interrupt Status Register
1061
- S3_0_c12_c1_1:
1062
- name: DISR_EL1
1063
- description: Deferred Interrupt Status Register
1064
- S3_0_c12_c8_0:
1065
- name: ICC_IAR0_EL1
1066
- description: Interrupt Controller Interrupt Acknowledge Register 0 Interrupt
1067
- Controller Virtual Interrupt Acknowledge Register 0
1068
- S3_0_c12_c8_1:
1069
- name: ICC_EOIR0_EL1
1070
- description: Interrupt Controller End Of Interrupt Register 0 Interrupt Controller
1071
- Virtual End Of Interrupt Register 0
1072
- S3_0_c12_c8_2:
1073
- name: ICC_HPPIR0_EL1
1074
- description: Interrupt Controller Highest Priority Pending Interrupt Register
1075
- 0 Interrupt Controller Virtual Highest Priority Pending Interrupt Register
1076
- 0
1077
- S3_0_c12_c8_3:
1078
- name: ICC_BPR0_EL1
1079
- description: Interrupt Controller Binary Point Register 0 Interrupt Controller
1080
- Virtual Binary Point Register 0
1081
- S3_0_c12_c8_4:
1082
- name: ICC_AP0R0_EL1
1083
- description: Interrupt Controller Active Priorities Group 0 Register 0 Interrupt
1084
- Controller Virtual Active Priorities Group 0 Register 0
1085
- S3_0_c12_c8_5:
1086
- name: ICC_AP0R1_EL1
1087
- description: Interrupt Controller Active Priorities Group 0 Register 1 Interrupt
1088
- Controller Virtual Active Priorities Group 0 Register 1
1089
- S3_0_c12_c8_6:
1090
- name: ICC_AP0R2_EL1
1091
- description: Interrupt Controller Active Priorities Group 0 Register 2 Interrupt
1092
- Controller Virtual Active Priorities Group 0 Register 2
1093
- S3_0_c12_c8_7:
1094
- name: ICC_AP0R3_EL1
1095
- description: Interrupt Controller Active Priorities Group 0 Register 3 Interrupt
1096
- Controller Virtual Active Priorities Group 0 Register 3
1097
- S3_0_c12_c9_0:
1098
- name: ICC_AP1R0_EL1
1099
- description: Interrupt Controller Active Priorities Group 1 Register 0 Interrupt
1100
- Controller Virtual Active Priorities Group 1 Register 0
1101
- S3_0_c12_c9_1:
1102
- name: ICC_AP1R1_EL1
1103
- description: Interrupt Controller Active Priorities Group 1 Register 1 Interrupt
1104
- Controller Virtual Active Priorities Group 1 Register 1
1105
- S3_0_c12_c9_2:
1106
- name: ICC_AP1R2_EL1
1107
- description: Interrupt Controller Active Priorities Group 1 Register 2 Interrupt
1108
- Controller Virtual Active Priorities Group 1 Register 2
1109
- S3_0_c12_c9_3:
1110
- name: ICC_AP1R3_EL1
1111
- description: Interrupt Controller Active Priorities Group 1 Register 3 Interrupt
1112
- Controller Virtual Active Priorities Group 1 Register 3
1113
- S3_0_c12_c11_1:
1114
- name: ICC_DIR_EL1
1115
- description: Interrupt Controller Deactivate Interrupt Register Interrupt Controller
1116
- Deactivate Virtual Interrupt Register
1117
- S3_0_c12_c11_3:
1118
- name: ICC_RPR_EL1
1119
- description: Interrupt Controller Running Priority Register Interrupt Controller
1120
- Virtual Running Priority Register
1121
- S3_0_c12_c11_5:
1122
- name: ICC_SGI1R_EL1
1123
- description: Interrupt Controller Software Generated Interrupt Group 1 Register
1124
- S3_0_c12_c11_6:
1125
- name: ICC_ASGI1R_EL1
1126
- description: Interrupt Controller Alias Software Generated Interrupt Group 1
1127
- Register
1128
- S3_0_c12_c11_7:
1129
- name: ICC_SGI0R_EL1
1130
- description: Interrupt Controller Software Generated Interrupt Group 0 Register
1131
- S3_0_c12_c12_0:
1132
- name: ICC_IAR1_EL1
1133
- description: Interrupt Controller Interrupt Acknowledge Register 1 Interrupt
1134
- Controller Virtual Interrupt Acknowledge Register 1
1135
- S3_0_c12_c12_1:
1136
- name: ICC_EOIR1_EL1
1137
- description: Interrupt Controller End Of Interrupt Register 1 Interrupt Controller
1138
- Virtual End Of Interrupt Register 1
1139
- S3_0_c12_c12_2:
1140
- name: ICC_HPPIR1_EL1
1141
- description: Interrupt Controller Highest Priority Pending Interrupt Register
1142
- 1 Interrupt Controller Virtual Highest Priority Pending Interrupt Register
1143
- 1
1144
- S3_0_c12_c12_3:
1145
- name: ICC_BPR1_EL1
1146
- description: Interrupt Controller Binary Point Register 1 Interrupt Controller
1147
- Virtual Binary Point Register 1
1148
- S3_0_c12_c12_4:
1149
- name: ICC_CTLR_EL1
1150
- description: Interrupt Controller Control Register (EL1) Interrupt Controller
1151
- Virtual Control Register
1152
- S3_0_c12_c12_5:
1153
- name: ICC_SRE_EL1
1154
- description: Interrupt Controller System Register Enable register (EL1)
1155
- S3_0_c12_c12_6:
1156
- name: ICC_IGRPEN0_EL1
1157
- description: Interrupt Controller Interrupt Group 0 Enable register Interrupt
1158
- Controller Virtual Interrupt Group 0 Enable register
1159
- S3_0_c12_c12_7:
1160
- name: ICC_IGRPEN1_EL1
1161
- description: Interrupt Controller Interrupt Group 1 Enable register Interrupt
1162
- Controller Virtual Interrupt Group 1 Enable register
1163
- S3_0_c13_c0_1:
1164
- name: CONTEXTIDR_EL1
1165
- description: Context ID Register (EL1)
1166
- S3_0_c13_c0_4:
1167
- name: TPIDR_EL1
1168
- description: EL1 Software Thread ID Register
1169
- S3_0_c13_c0_7:
1170
- name: SCXTNUM_EL1
1171
- description: EL1 Read/Write Software Context Number
1172
- S3_0_c14_c1_0:
1173
- name: CNTKCTL_EL1
1174
- description: Counter-timer Kernel Control register
1175
- S3_1_c0_c0_0:
1176
- name: CCSIDR_EL1
1177
- description: Current Cache Size ID Register
1178
- S3_1_c0_c0_1:
1179
- name: CLIDR_EL1
1180
- description: Cache Level ID Register
1181
- S3_1_c0_c0_2:
1182
- name: CCSIDR2_EL1
1183
- description: Current Cache Size ID Register 2
1184
- S3_1_c0_c0_4:
1185
- name: GMID_EL1
1186
- description: " Multiple tag transfer ID register"
1187
- S3_1_c0_c0_7:
1188
- name: AIDR_EL1
1189
- description: Auxiliary ID Register
1190
- S3_2_c0_c0_0:
1191
- name: CSSELR_EL1
1192
- description: Cache Size Selection Register
1193
- S3_3_c0_c0_1:
1194
- name: CTR_EL0
1195
- description: Cache Type Register
1196
- S3_3_c0_c0_7:
1197
- name: DCZID_EL0
1198
- description: Data Cache Zero ID register
1199
- S3_3_c2_c4_0:
1200
- name: RNDR
1201
- description: Random Number
1202
- S3_3_c2_c4_1:
1203
- name: RNDRRS
1204
- description: Reseeded Random Number
1205
- S3_3_c4_c2_0:
1206
- name: NZCV
1207
- description: Condition Flags
1208
- S3_3_c4_c2_1:
1209
- name: DAIF
1210
- description: Interrupt Mask Bits
1211
- S3_3_c4_c2_5:
1212
- name: DIT
1213
- description: Data Independent Timing
1214
- S3_3_c4_c2_6:
1215
- name: SSBS
1216
- description: Speculative Store Bypass Safe
1217
- S3_3_c4_c2_7:
1218
- name: TCO
1219
- description: Tag Check Override
1220
- S3_3_c4_c4_0:
1221
- name: FPCR
1222
- description: Floating-point Control Register
1223
- S3_3_c4_c4_1:
1224
- name: FPSR
1225
- description: Floating-point Status Register
1226
- S3_3_c4_c5_0:
1227
- name: DSPSR_EL0
1228
- description: Debug Saved Program Status Register
1229
- S3_3_c4_c5_1:
1230
- name: DLR_EL0
1231
- description: Debug Link Register
1232
- S3_3_c9_c12_0:
1233
- name: PMCR_EL0
1234
- description: Performance Monitors Control Register
1235
- S3_3_c9_c12_1:
1236
- name: PMCNTENSET_EL0
1237
- description: Performance Monitors Count Enable Set register
1238
- S3_3_c9_c12_2:
1239
- name: PMCNTENCLR_EL0
1240
- description: Performance Monitors Count Enable Clear register
1241
- S3_3_c9_c12_3:
1242
- name: PMOVSCLR_EL0
1243
- description: Performance Monitors Overflow Flag Status Clear Register
1244
- S3_3_c9_c12_4:
1245
- name: PMSWINC_EL0
1246
- description: Performance Monitors Software Increment register
1247
- S3_3_c9_c12_5:
1248
- name: PMSELR_EL0
1249
- description: Performance Monitors Event Counter Selection Register
1250
- S3_3_c9_c12_6:
1251
- name: PMCEID0_EL0
1252
- description: Performance Monitors Common Event Identification register 0
1253
- S3_3_c9_c12_7:
1254
- name: PMCEID1_EL0
1255
- description: Performance Monitors Common Event Identification register 1
1256
- S3_3_c9_c13_0:
1257
- name: PMCCNTR_EL0
1258
- description: Performance Monitors Cycle Count Register
1259
- S3_3_c9_c13_1:
1260
- name: PMXEVTYPER_EL0
1261
- description: Performance Monitors Selected Event Type Register
1262
- S3_3_c9_c13_2:
1263
- name: PMXEVCNTR_EL0
1264
- description: Performance Monitors Selected Event Count Register
1265
- S3_3_c9_c14_0:
1266
- name: PMUSERENR_EL0
1267
- description: Performance Monitors User Enable Register
1268
- S3_3_c9_c14_3:
1269
- name: PMOVSSET_EL0
1270
- description: Performance Monitors Overflow Flag Status Set register
1271
- S3_3_c13_c0_2:
1272
- name: TPIDR_EL0
1273
- description: EL0 Read/Write Software Thread ID Register
1274
- S3_3_c13_c0_3:
1275
- name: TPIDRRO_EL0
1276
- description: EL0 Read-Only Software Thread ID Register
1277
- S3_3_c13_c0_7:
1278
- name: SCXTNUM_EL0
1279
- description: EL0 Read/Write Software Context Number
1280
- S3_3_c13_c2_0:
1281
- name: AMCR_EL0
1282
- description: Activity Monitors Control Register
1283
- S3_3_c13_c2_1:
1284
- name: AMCFGR_EL0
1285
- description: Activity Monitors Configuration Register
1286
- S3_3_c13_c2_2:
1287
- name: AMCGCR_EL0
1288
- description: Activity Monitors Counter Group Configuration Register
1289
- S3_3_c13_c2_3:
1290
- name: AMUSERENR_EL0
1291
- description: Activity Monitors User Enable Register
1292
- S3_3_c13_c2_4:
1293
- name: AMCNTENCLR0_EL0
1294
- description: Activity Monitors Count Enable Clear Register 0
1295
- S3_3_c13_c2_5:
1296
- name: AMCNTENSET0_EL0
1297
- description: Activity Monitors Count Enable Set Register 0
1298
- S3_3_c13_c2_6:
1299
- name: AMCG1IDR_EL0
1300
- description: Activity Monitors Counter Group 1 Identification Register
1301
- S3_3_c13_c3_0:
1302
- name: AMCNTENCLR1_EL0
1303
- description: Activity Monitors Count Enable Clear Register 1
1304
- S3_3_c13_c3_1:
1305
- name: AMCNTENSET1_EL0
1306
- description: Activity Monitors Count Enable Set Register 1
1307
- S3_3_c13_c4_0:
1308
- name: AMEVCNTR00_EL0
1309
- description: Activity Monitors Event Counter Register 0 0
1310
- S3_3_c13_c4_1:
1311
- name: AMEVCNTR01_EL0
1312
- description: Activity Monitors Event Counter Register 0 1
1313
- S3_3_c13_c4_2:
1314
- name: AMEVCNTR02_EL0
1315
- description: Activity Monitors Event Counter Register 0 2
1316
- S3_3_c13_c4_3:
1317
- name: AMEVCNTR03_EL0
1318
- description: Activity Monitors Event Counter Register 0 3
1319
- S3_3_c13_c4_4:
1320
- name: AMEVCNTR04_EL0
1321
- description: Activity Monitors Event Counter Register 0 4
1322
- S3_3_c13_c4_5:
1323
- name: AMEVCNTR05_EL0
1324
- description: Activity Monitors Event Counter Register 0 5
1325
- S3_3_c13_c4_6:
1326
- name: AMEVCNTR06_EL0
1327
- description: Activity Monitors Event Counter Register 0 6
1328
- S3_3_c13_c4_7:
1329
- name: AMEVCNTR07_EL0
1330
- description: Activity Monitors Event Counter Register 0 7
1331
- S3_3_c13_c5_0:
1332
- name: AMEVCNTR08_EL0
1333
- description: Activity Monitors Event Counter Register 0 8
1334
- S3_3_c13_c5_1:
1335
- name: AMEVCNTR09_EL0
1336
- description: Activity Monitors Event Counter Register 0 9
1337
- S3_3_c13_c5_2:
1338
- name: AMEVCNTR010_EL0
1339
- description: Activity Monitors Event Counter Register 0 10
1340
- S3_3_c13_c5_3:
1341
- name: AMEVCNTR011_EL0
1342
- description: Activity Monitors Event Counter Register 0 11
1343
- S3_3_c13_c5_4:
1344
- name: AMEVCNTR012_EL0
1345
- description: Activity Monitors Event Counter Register 0 12
1346
- S3_3_c13_c5_5:
1347
- name: AMEVCNTR013_EL0
1348
- description: Activity Monitors Event Counter Register 0 13
1349
- S3_3_c13_c5_6:
1350
- name: AMEVCNTR014_EL0
1351
- description: Activity Monitors Event Counter Register 0 14
1352
- S3_3_c13_c5_7:
1353
- name: AMEVCNTR015_EL0
1354
- description: Activity Monitors Event Counter Register 0 15
1355
- S3_3_c13_c6_0:
1356
- name: AMEVTYPER00_EL0
1357
- description: Activity Monitors Event Type Register 0 0
1358
- S3_3_c13_c6_1:
1359
- name: AMEVTYPER01_EL0
1360
- description: Activity Monitors Event Type Register 0 1
1361
- S3_3_c13_c6_2:
1362
- name: AMEVTYPER02_EL0
1363
- description: Activity Monitors Event Type Register 0 2
1364
- S3_3_c13_c6_3:
1365
- name: AMEVTYPER03_EL0
1366
- description: Activity Monitors Event Type Register 0 3
1367
- S3_3_c13_c6_4:
1368
- name: AMEVTYPER04_EL0
1369
- description: Activity Monitors Event Type Register 0 4
1370
- S3_3_c13_c6_5:
1371
- name: AMEVTYPER05_EL0
1372
- description: Activity Monitors Event Type Register 0 5
1373
- S3_3_c13_c6_6:
1374
- name: AMEVTYPER06_EL0
1375
- description: Activity Monitors Event Type Register 0 6
1376
- S3_3_c13_c6_7:
1377
- name: AMEVTYPER07_EL0
1378
- description: Activity Monitors Event Type Register 0 7
1379
- S3_3_c13_c7_0:
1380
- name: AMEVTYPER08_EL0
1381
- description: Activity Monitors Event Type Register 0 8
1382
- S3_3_c13_c7_1:
1383
- name: AMEVTYPER09_EL0
1384
- description: Activity Monitors Event Type Register 0 9
1385
- S3_3_c13_c7_2:
1386
- name: AMEVTYPER010_EL0
1387
- description: Activity Monitors Event Type Register 0 10
1388
- S3_3_c13_c7_3:
1389
- name: AMEVTYPER011_EL0
1390
- description: Activity Monitors Event Type Register 0 11
1391
- S3_3_c13_c7_4:
1392
- name: AMEVTYPER012_EL0
1393
- description: Activity Monitors Event Type Register 0 12
1394
- S3_3_c13_c7_5:
1395
- name: AMEVTYPER013_EL0
1396
- description: Activity Monitors Event Type Register 0 13
1397
- S3_3_c13_c7_6:
1398
- name: AMEVTYPER014_EL0
1399
- description: Activity Monitors Event Type Register 0 14
1400
- S3_3_c13_c7_7:
1401
- name: AMEVTYPER015_EL0
1402
- description: Activity Monitors Event Type Register 0 15
1403
- S3_3_c13_c12_0:
1404
- name: AMEVCNTR10_EL0
1405
- description: Activity Monitors Event Counter Register 1 0
1406
- S3_3_c13_c12_1:
1407
- name: AMEVCNTR11_EL0
1408
- description: Activity Monitors Event Counter Register 1 1
1409
- S3_3_c13_c12_2:
1410
- name: AMEVCNTR12_EL0
1411
- description: Activity Monitors Event Counter Register 1 2
1412
- S3_3_c13_c12_3:
1413
- name: AMEVCNTR13_EL0
1414
- description: Activity Monitors Event Counter Register 1 3
1415
- S3_3_c13_c12_4:
1416
- name: AMEVCNTR14_EL0
1417
- description: Activity Monitors Event Counter Register 1 4
1418
- S3_3_c13_c12_5:
1419
- name: AMEVCNTR15_EL0
1420
- description: Activity Monitors Event Counter Register 1 5
1421
- S3_3_c13_c12_6:
1422
- name: AMEVCNTR16_EL0
1423
- description: Activity Monitors Event Counter Register 1 6
1424
- S3_3_c13_c12_7:
1425
- name: AMEVCNTR17_EL0
1426
- description: Activity Monitors Event Counter Register 1 7
1427
- S3_3_c13_c13_0:
1428
- name: AMEVCNTR18_EL0
1429
- description: Activity Monitors Event Counter Register 1 8
1430
- S3_3_c13_c13_1:
1431
- name: AMEVCNTR19_EL0
1432
- description: Activity Monitors Event Counter Register 1 9
1433
- S3_3_c13_c13_2:
1434
- name: AMEVCNTR110_EL0
1435
- description: Activity Monitors Event Counter Register 1 10
1436
- S3_3_c13_c13_3:
1437
- name: AMEVCNTR111_EL0
1438
- description: Activity Monitors Event Counter Register 1 11
1439
- S3_3_c13_c13_4:
1440
- name: AMEVCNTR112_EL0
1441
- description: Activity Monitors Event Counter Register 1 12
1442
- S3_3_c13_c13_5:
1443
- name: AMEVCNTR113_EL0
1444
- description: Activity Monitors Event Counter Register 1 13
1445
- S3_3_c13_c13_6:
1446
- name: AMEVCNTR114_EL0
1447
- description: Activity Monitors Event Counter Register 1 14
1448
- S3_3_c13_c13_7:
1449
- name: AMEVCNTR115_EL0
1450
- description: Activity Monitors Event Counter Register 1 15
1451
- S3_3_c13_c14_0:
1452
- name: AMEVTYPER10_EL0
1453
- description: Activity Monitors Event Type Register 1 0
1454
- S3_3_c13_c14_1:
1455
- name: AMEVTYPER11_EL0
1456
- description: Activity Monitors Event Type Register 1 1
1457
- S3_3_c13_c14_2:
1458
- name: AMEVTYPER12_EL0
1459
- description: Activity Monitors Event Type Register 1 2
1460
- S3_3_c13_c14_3:
1461
- name: AMEVTYPER13_EL0
1462
- description: Activity Monitors Event Type Register 1 3
1463
- S3_3_c13_c14_4:
1464
- name: AMEVTYPER14_EL0
1465
- description: Activity Monitors Event Type Register 1 4
1466
- S3_3_c13_c14_5:
1467
- name: AMEVTYPER15_EL0
1468
- description: Activity Monitors Event Type Register 1 5
1469
- S3_3_c13_c14_6:
1470
- name: AMEVTYPER16_EL0
1471
- description: Activity Monitors Event Type Register 1 6
1472
- S3_3_c13_c14_7:
1473
- name: AMEVTYPER17_EL0
1474
- description: Activity Monitors Event Type Register 1 7
1475
- S3_3_c13_c15_0:
1476
- name: AMEVTYPER18_EL0
1477
- description: Activity Monitors Event Type Register 1 8
1478
- S3_3_c13_c15_1:
1479
- name: AMEVTYPER19_EL0
1480
- description: Activity Monitors Event Type Register 1 9
1481
- S3_3_c13_c15_2:
1482
- name: AMEVTYPER110_EL0
1483
- description: Activity Monitors Event Type Register 1 10
1484
- S3_3_c13_c15_3:
1485
- name: AMEVTYPER111_EL0
1486
- description: Activity Monitors Event Type Register 1 11
1487
- S3_3_c13_c15_4:
1488
- name: AMEVTYPER112_EL0
1489
- description: Activity Monitors Event Type Register 1 12
1490
- S3_3_c13_c15_5:
1491
- name: AMEVTYPER113_EL0
1492
- description: Activity Monitors Event Type Register 1 13
1493
- S3_3_c13_c15_6:
1494
- name: AMEVTYPER114_EL0
1495
- description: Activity Monitors Event Type Register 1 14
1496
- S3_3_c13_c15_7:
1497
- name: AMEVTYPER115_EL0
1498
- description: Activity Monitors Event Type Register 1 15
1499
- S3_3_c14_c0_0:
1500
- name: CNTFRQ_EL0
1501
- description: Counter-timer Frequency register
1502
- S3_3_c14_c0_1:
1503
- name: CNTPCT_EL0
1504
- description: Counter-timer Physical Count register
1505
- S3_3_c14_c0_2:
1506
- name: CNTVCT_EL0
1507
- description: Counter-timer Virtual Count register
1508
- S3_3_c14_c0_5:
1509
- name: CNTPCTSS_EL0
1510
- description: Counter-timer Self-Synchronized Physical Count register
1511
- S3_3_c14_c0_6:
1512
- name: CNTVCTSS_EL0
1513
- description: Counter-timer Self-Synchronized Virtual Count register
1514
- S3_3_c14_c2_0:
1515
- name: CNTP_TVAL_EL0
1516
- description: Counter-timer Physical Timer TimerValue register
1517
- S3_3_c14_c2_1:
1518
- name: CNTP_CTL_EL0
1519
- description: Counter-timer Physical Timer Control register
1520
- S3_3_c14_c2_2:
1521
- name: CNTP_CVAL_EL0
1522
- description: Counter-timer Physical Timer CompareValue register
1523
- S3_3_c14_c3_0:
1524
- name: CNTV_TVAL_EL0
1525
- description: Counter-timer Virtual Timer TimerValue register
1526
- S3_3_c14_c3_1:
1527
- name: CNTV_CTL_EL0
1528
- description: Counter-timer Virtual Timer Control register
1529
- S3_3_c14_c3_2:
1530
- name: CNTV_CVAL_EL0
1531
- description: Counter-timer Virtual Timer CompareValue register
1532
- S3_3_c14_c8_0:
1533
- name: PMEVCNTR0_EL0
1534
- description: Performance Monitors Event Count Register 0
1535
- S3_3_c14_c8_1:
1536
- name: PMEVCNTR1_EL0
1537
- description: Performance Monitors Event Count Register 1
1538
- S3_3_c14_c8_2:
1539
- name: PMEVCNTR2_EL0
1540
- description: Performance Monitors Event Count Register 2
1541
- S3_3_c14_c8_3:
1542
- name: PMEVCNTR3_EL0
1543
- description: Performance Monitors Event Count Register 3
1544
- S3_3_c14_c8_4:
1545
- name: PMEVCNTR4_EL0
1546
- description: Performance Monitors Event Count Register 4
1547
- S3_3_c14_c8_5:
1548
- name: PMEVCNTR5_EL0
1549
- description: Performance Monitors Event Count Register 5
1550
- S3_3_c14_c8_6:
1551
- name: PMEVCNTR6_EL0
1552
- description: Performance Monitors Event Count Register 6
1553
- S3_3_c14_c8_7:
1554
- name: PMEVCNTR7_EL0
1555
- description: Performance Monitors Event Count Register 7
1556
- S3_3_c14_c9_0:
1557
- name: PMEVCNTR8_EL0
1558
- description: Performance Monitors Event Count Register 8
1559
- S3_3_c14_c9_1:
1560
- name: PMEVCNTR9_EL0
1561
- description: Performance Monitors Event Count Register 9
1562
- S3_3_c14_c9_2:
1563
- name: PMEVCNTR10_EL0
1564
- description: Performance Monitors Event Count Register 10
1565
- S3_3_c14_c9_3:
1566
- name: PMEVCNTR11_EL0
1567
- description: Performance Monitors Event Count Register 11
1568
- S3_3_c14_c9_4:
1569
- name: PMEVCNTR12_EL0
1570
- description: Performance Monitors Event Count Register 12
1571
- S3_3_c14_c9_5:
1572
- name: PMEVCNTR13_EL0
1573
- description: Performance Monitors Event Count Register 13
1574
- S3_3_c14_c9_6:
1575
- name: PMEVCNTR14_EL0
1576
- description: Performance Monitors Event Count Register 14
1577
- S3_3_c14_c9_7:
1578
- name: PMEVCNTR15_EL0
1579
- description: Performance Monitors Event Count Register 15
1580
- S3_3_c14_c10_0:
1581
- name: PMEVCNTR16_EL0
1582
- description: Performance Monitors Event Count Register 16
1583
- S3_3_c14_c10_1:
1584
- name: PMEVCNTR17_EL0
1585
- description: Performance Monitors Event Count Register 17
1586
- S3_3_c14_c10_2:
1587
- name: PMEVCNTR18_EL0
1588
- description: Performance Monitors Event Count Register 18
1589
- S3_3_c14_c10_3:
1590
- name: PMEVCNTR19_EL0
1591
- description: Performance Monitors Event Count Register 19
1592
- S3_3_c14_c10_4:
1593
- name: PMEVCNTR20_EL0
1594
- description: Performance Monitors Event Count Register 20
1595
- S3_3_c14_c10_5:
1596
- name: PMEVCNTR21_EL0
1597
- description: Performance Monitors Event Count Register 21
1598
- S3_3_c14_c10_6:
1599
- name: PMEVCNTR22_EL0
1600
- description: Performance Monitors Event Count Register 22
1601
- S3_3_c14_c10_7:
1602
- name: PMEVCNTR23_EL0
1603
- description: Performance Monitors Event Count Register 23
1604
- S3_3_c14_c11_0:
1605
- name: PMEVCNTR24_EL0
1606
- description: Performance Monitors Event Count Register 24
1607
- S3_3_c14_c11_1:
1608
- name: PMEVCNTR25_EL0
1609
- description: Performance Monitors Event Count Register 25
1610
- S3_3_c14_c11_2:
1611
- name: PMEVCNTR26_EL0
1612
- description: Performance Monitors Event Count Register 26
1613
- S3_3_c14_c11_3:
1614
- name: PMEVCNTR27_EL0
1615
- description: Performance Monitors Event Count Register 27
1616
- S3_3_c14_c11_4:
1617
- name: PMEVCNTR28_EL0
1618
- description: Performance Monitors Event Count Register 28
1619
- S3_3_c14_c11_5:
1620
- name: PMEVCNTR29_EL0
1621
- description: Performance Monitors Event Count Register 29
1622
- S3_3_c14_c11_6:
1623
- name: PMEVCNTR30_EL0
1624
- description: Performance Monitors Event Count Register 30
1625
- S3_3_c14_c11_7:
1626
- name: PMEVCNTR31_EL0
1627
- description: Performance Monitors Event Count Register 31
1628
- S3_3_c14_c12_0:
1629
- name: PMEVTYPER0_EL0
1630
- description: Performance Monitors Event Type Register 0
1631
- S3_3_c14_c12_1:
1632
- name: PMEVTYPER1_EL0
1633
- description: Performance Monitors Event Type Register 1
1634
- S3_3_c14_c12_2:
1635
- name: PMEVTYPER2_EL0
1636
- description: Performance Monitors Event Type Register 2
1637
- S3_3_c14_c12_3:
1638
- name: PMEVTYPER3_EL0
1639
- description: Performance Monitors Event Type Register 3
1640
- S3_3_c14_c12_4:
1641
- name: PMEVTYPER4_EL0
1642
- description: Performance Monitors Event Type Register 4
1643
- S3_3_c14_c12_5:
1644
- name: PMEVTYPER5_EL0
1645
- description: Performance Monitors Event Type Register 5
1646
- S3_3_c14_c12_6:
1647
- name: PMEVTYPER6_EL0
1648
- description: Performance Monitors Event Type Register 6
1649
- S3_3_c14_c12_7:
1650
- name: PMEVTYPER7_EL0
1651
- description: Performance Monitors Event Type Register 7
1652
- S3_3_c14_c13_0:
1653
- name: PMEVTYPER8_EL0
1654
- description: Performance Monitors Event Type Register 8
1655
- S3_3_c14_c13_1:
1656
- name: PMEVTYPER9_EL0
1657
- description: Performance Monitors Event Type Register 9
1658
- S3_3_c14_c13_2:
1659
- name: PMEVTYPER10_EL0
1660
- description: Performance Monitors Event Type Register 10
1661
- S3_3_c14_c13_3:
1662
- name: PMEVTYPER11_EL0
1663
- description: Performance Monitors Event Type Register 11
1664
- S3_3_c14_c13_4:
1665
- name: PMEVTYPER12_EL0
1666
- description: Performance Monitors Event Type Register 12
1667
- S3_3_c14_c13_5:
1668
- name: PMEVTYPER13_EL0
1669
- description: Performance Monitors Event Type Register 13
1670
- S3_3_c14_c13_6:
1671
- name: PMEVTYPER14_EL0
1672
- description: Performance Monitors Event Type Register 14
1673
- S3_3_c14_c13_7:
1674
- name: PMEVTYPER15_EL0
1675
- description: Performance Monitors Event Type Register 15
1676
- S3_3_c14_c14_0:
1677
- name: PMEVTYPER16_EL0
1678
- description: Performance Monitors Event Type Register 16
1679
- S3_3_c14_c14_1:
1680
- name: PMEVTYPER17_EL0
1681
- description: Performance Monitors Event Type Register 17
1682
- S3_3_c14_c14_2:
1683
- name: PMEVTYPER18_EL0
1684
- description: Performance Monitors Event Type Register 18
1685
- S3_3_c14_c14_3:
1686
- name: PMEVTYPER19_EL0
1687
- description: Performance Monitors Event Type Register 19
1688
- S3_3_c14_c14_4:
1689
- name: PMEVTYPER20_EL0
1690
- description: Performance Monitors Event Type Register 20
1691
- S3_3_c14_c14_5:
1692
- name: PMEVTYPER21_EL0
1693
- description: Performance Monitors Event Type Register 21
1694
- S3_3_c14_c14_6:
1695
- name: PMEVTYPER22_EL0
1696
- description: Performance Monitors Event Type Register 22
1697
- S3_3_c14_c14_7:
1698
- name: PMEVTYPER23_EL0
1699
- description: Performance Monitors Event Type Register 23
1700
- S3_3_c14_c15_0:
1701
- name: PMEVTYPER24_EL0
1702
- description: Performance Monitors Event Type Register 24
1703
- S3_3_c14_c15_1:
1704
- name: PMEVTYPER25_EL0
1705
- description: Performance Monitors Event Type Register 25
1706
- S3_3_c14_c15_2:
1707
- name: PMEVTYPER26_EL0
1708
- description: Performance Monitors Event Type Register 26
1709
- S3_3_c14_c15_3:
1710
- name: PMEVTYPER27_EL0
1711
- description: Performance Monitors Event Type Register 27
1712
- S3_3_c14_c15_4:
1713
- name: PMEVTYPER28_EL0
1714
- description: Performance Monitors Event Type Register 28
1715
- S3_3_c14_c15_5:
1716
- name: PMEVTYPER29_EL0
1717
- description: Performance Monitors Event Type Register 29
1718
- S3_3_c14_c15_6:
1719
- name: PMEVTYPER30_EL0
1720
- description: Performance Monitors Event Type Register 30
1721
- S3_3_c14_c15_7:
1722
- name: PMCCFILTR_EL0
1723
- description: Performance Monitors Cycle Count Filter Register Performance Monitors
1724
- Event Type Register 31
1725
- S3_4_c0_c0_0:
1726
- name: VPIDR_EL2
1727
- description: Virtualization Processor ID Register
1728
- S3_4_c0_c0_5:
1729
- name: VMPIDR_EL2
1730
- description: Virtualization Multiprocessor ID Register
1731
- S3_4_c1_c0_0:
1732
- name: SCTLR_EL2
1733
- description: System Control Register (EL2)
1734
- S3_4_c1_c0_1:
1735
- name: ACTLR_EL2
1736
- description: Auxiliary Control Register (EL2)
1737
- S3_4_c1_c1_0:
1738
- name: HCR_EL2
1739
- description: Hypervisor Configuration Register
1740
- S3_4_c1_c1_1:
1741
- name: MDCR_EL2
1742
- description: Monitor Debug Configuration Register (EL2)
1743
- S3_4_c1_c1_2:
1744
- name: CPTR_EL2
1745
- description: Architectural Feature Trap Register (EL2)
1746
- S3_4_c1_c1_3:
1747
- name: HSTR_EL2
1748
- description: Hypervisor System Trap Register
1749
- S3_4_c1_c1_4:
1750
- name: HFGRTR_EL2
1751
- description: Hypervisor Fine-Grained Read Trap Register
1752
- S3_4_c1_c1_5:
1753
- name: HFGWTR_EL2
1754
- description: Hypervisor Fine-Grained Write Trap Register
1755
- S3_4_c1_c1_6:
1756
- name: HFGITR_EL2
1757
- description: Hypervisor Fine-Grained Instruction Trap Register
1758
- S3_4_c1_c1_7:
1759
- name: HACR_EL2
1760
- description: Hypervisor Auxiliary Control Register
1761
- S3_4_c1_c2_0:
1762
- name: ZCR_EL2
1763
- description: SVE Control Register for EL2
1764
- S3_4_c1_c2_1:
1765
- name: TRFCR_EL2
1766
- description: Trace Filter Control Register (EL2)
1767
- S3_4_c1_c3_1:
1768
- name: SDER32_EL2
1769
- description: AArch32 Secure Debug Enable Register
1770
- S3_4_c2_c0_0:
1771
- name: TTBR0_EL2
1772
- description: Translation Table Base Register 0 (EL2)
1773
- S3_4_c2_c0_1:
1774
- name: TTBR1_EL2
1775
- description: Translation Table Base Register 1 (EL2)
1776
- S3_4_c2_c0_2:
1777
- name: TCR_EL2
1778
- description: Translation Control Register (EL2)
1779
- S3_4_c2_c1_0:
1780
- name: VTTBR_EL2
1781
- description: Virtualization Translation Table Base Register
1782
- S3_4_c2_c1_2:
1783
- name: VTCR_EL2
1784
- description: Virtualization Translation Control Register
1785
- S3_4_c2_c2_0:
1786
- name: VNCR_EL2
1787
- description: Virtual Nested Control Register
1788
- S3_4_c2_c6_0:
1789
- name: VSTTBR_EL2
1790
- description: Virtualization Secure Translation Table Base Register
1791
- S3_4_c2_c6_2:
1792
- name: VSTCR_EL2
1793
- description: Virtualization Secure Translation Control Register
1794
- S3_4_c3_c0_0:
1795
- name: DACR32_EL2
1796
- description: Domain Access Control Register
1797
- S3_4_c3_c1_4:
1798
- name: HDFGRTR_EL2
1799
- description: Hypervisor Debug Fine-Grained Read Trap Register
1800
- S3_4_c3_c1_5:
1801
- name: HDFGWTR_EL2
1802
- description: Hypervisor Debug Fine-Grained Write Trap Register
1803
- S3_4_c3_c1_6:
1804
- name: HAFGRTR_EL2
1805
- description: Hypervisor Activity Monitors Fine-Grained Read Trap Register
1806
- S3_4_c4_c0_0:
1807
- name: SPSR_EL2
1808
- description: Saved Program Status Register (EL2)
1809
- S3_4_c4_c0_1:
1810
- name: ELR_EL2
1811
- description: Exception Link Register (EL2)
1812
- S3_4_c4_c1_0:
1813
- name: SP_EL1
1814
- description: Stack Pointer (EL1)
1815
- S3_4_c4_c3_0:
1816
- name: SPSR_irq
1817
- description: Saved Program Status Register (IRQ mode)
1818
- S3_4_c4_c3_1:
1819
- name: SPSR_abt
1820
- description: Saved Program Status Register (Abort mode)
1821
- S3_4_c4_c3_2:
1822
- name: SPSR_und
1823
- description: Saved Program Status Register (Undefined mode)
1824
- S3_4_c4_c3_3:
1825
- name: SPSR_fiq
1826
- description: Saved Program Status Register (FIQ mode)
1827
- S3_4_c5_c0_1:
1828
- name: IFSR32_EL2
1829
- description: Instruction Fault Status Register (EL2)
1830
- S3_4_c5_c1_0:
1831
- name: AFSR0_EL2
1832
- description: Auxiliary Fault Status Register 0 (EL2)
1833
- S3_4_c5_c1_1:
1834
- name: AFSR1_EL2
1835
- description: Auxiliary Fault Status Register 1 (EL2)
1836
- S3_4_c5_c2_0:
1837
- name: ESR_EL2
1838
- description: Exception Syndrome Register (EL2)
1839
- S3_4_c5_c2_3:
1840
- name: VSESR_EL2
1841
- description: Virtual SError Exception Syndrome Register
1842
- S3_4_c5_c3_0:
1843
- name: FPEXC32_EL2
1844
- description: Floating-Point Exception Control register
1845
- S3_4_c5_c6_0:
1846
- name: TFSR_EL2
1847
- description: Tag Fault Status Register (EL2)
1848
- S3_4_c6_c0_0:
1849
- name: FAR_EL2
1850
- description: Fault Address Register (EL2)
1851
- S3_4_c6_c0_4:
1852
- name: HPFAR_EL2
1853
- description: Hypervisor IPA Fault Address Register
1854
- S3_4_c9_c9_0:
1855
- name: PMSCR_EL2
1856
- description: Statistical Profiling Control Register (EL2)
1857
- S3_4_c10_c2_0:
1858
- name: MAIR_EL2
1859
- description: Memory Attribute Indirection Register (EL2)
1860
- S3_4_c10_c3_0:
1861
- name: AMAIR_EL2
1862
- description: Auxiliary Memory Attribute Indirection Register (EL2)
1863
- S3_4_c10_c4_0:
1864
- name: MPAMHCR_EL2
1865
- description: MPAM Hypervisor Control Register (EL2)
1866
- S3_4_c10_c4_1:
1867
- name: MPAMVPMV_EL2
1868
- description: MPAM Virtual Partition Mapping Valid Register
1869
- S3_4_c10_c5_0:
1870
- name: MPAM2_EL2
1871
- description: MPAM2 Register (EL2)
1872
- S3_4_c10_c6_0:
1873
- name: MPAMVPM0_EL2
1874
- description: MPAM Virtual PARTID Mapping Register 0
1875
- S3_4_c10_c6_1:
1876
- name: MPAMVPM1_EL2
1877
- description: MPAM Virtual PARTID Mapping Register 1
1878
- S3_4_c10_c6_2:
1879
- name: MPAMVPM2_EL2
1880
- description: MPAM Virtual PARTID Mapping Register 2
1881
- S3_4_c10_c6_3:
1882
- name: MPAMVPM3_EL2
1883
- description: MPAM Virtual PARTID Mapping Register 3
1884
- S3_4_c10_c6_4:
1885
- name: MPAMVPM4_EL2
1886
- description: MPAM Virtual PARTID Mapping Register 4
1887
- S3_4_c10_c6_5:
1888
- name: MPAMVPM5_EL2
1889
- description: MPAM Virtual PARTID Mapping Register 5
1890
- S3_4_c10_c6_6:
1891
- name: MPAMVPM6_EL2
1892
- description: MPAM Virtual PARTID Mapping Register 6
1893
- S3_4_c10_c6_7:
1894
- name: MPAMVPM7_EL2
1895
- description: MPAM Virtual PARTID Mapping Register 7
1896
- S3_4_c12_c0_0:
1897
- name: VBAR_EL2
1898
- description: Vector Base Address Register (EL2)
1899
- S3_4_c12_c0_1:
1900
- name: RVBAR_EL2
1901
- description: Reset Vector Base Address Register (if EL3 not implemented)
1902
- S3_4_c12_c0_2:
1903
- name: RMR_EL2
1904
- description: Reset Management Register (EL2)
1905
- S3_4_c12_c1_1:
1906
- name: VDISR_EL2
1907
- description: Virtual Deferred Interrupt Status Register
1908
- S3_4_c12_c8_0:
1909
- name: ICH_AP0R0_EL2
1910
- description: Interrupt Controller Hyp Active Priorities Group 0 Register 0
1911
- S3_4_c12_c8_1:
1912
- name: ICH_AP0R1_EL2
1913
- description: Interrupt Controller Hyp Active Priorities Group 0 Register 1
1914
- S3_4_c12_c8_2:
1915
- name: ICH_AP0R2_EL2
1916
- description: Interrupt Controller Hyp Active Priorities Group 0 Register 2
1917
- S3_4_c12_c8_3:
1918
- name: ICH_AP0R3_EL2
1919
- description: Interrupt Controller Hyp Active Priorities Group 0 Register 3
1920
- S3_4_c12_c9_0:
1921
- name: ICH_AP1R0_EL2
1922
- description: Interrupt Controller Hyp Active Priorities Group 1 Register 0
1923
- S3_4_c12_c9_1:
1924
- name: ICH_AP1R1_EL2
1925
- description: Interrupt Controller Hyp Active Priorities Group 1 Register 1
1926
- S3_4_c12_c9_2:
1927
- name: ICH_AP1R2_EL2
1928
- description: Interrupt Controller Hyp Active Priorities Group 1 Register 2
1929
- S3_4_c12_c9_3:
1930
- name: ICH_AP1R3_EL2
1931
- description: Interrupt Controller Hyp Active Priorities Group 1 Register 3
1932
- S3_4_c12_c9_5:
1933
- name: ICC_SRE_EL2
1934
- description: Interrupt Controller System Register Enable register (EL2)
1935
- S3_4_c12_c11_0:
1936
- name: ICH_HCR_EL2
1937
- description: Interrupt Controller Hyp Control Register
1938
- S3_4_c12_c11_1:
1939
- name: ICH_VTR_EL2
1940
- description: Interrupt Controller VGIC Type Register
1941
- S3_4_c12_c11_2:
1942
- name: ICH_MISR_EL2
1943
- description: Interrupt Controller Maintenance Interrupt State Register
1944
- S3_4_c12_c11_3:
1945
- name: ICH_EISR_EL2
1946
- description: Interrupt Controller End of Interrupt Status Register
1947
- S3_4_c12_c11_5:
1948
- name: ICH_ELRSR_EL2
1949
- description: Interrupt Controller Empty List Register Status Register
1950
- S3_4_c12_c11_7:
1951
- name: ICH_VMCR_EL2
1952
- description: Interrupt Controller Virtual Machine Control Register
1953
- S3_4_c12_c12_0:
1954
- name: ICH_LR0_EL2
1955
- description: Interrupt Controller List Register 0
1956
- S3_4_c12_c12_1:
1957
- name: ICH_LR1_EL2
1958
- description: Interrupt Controller List Register 1
1959
- S3_4_c12_c12_2:
1960
- name: ICH_LR2_EL2
1961
- description: Interrupt Controller List Register 2
1962
- S3_4_c12_c12_3:
1963
- name: ICH_LR3_EL2
1964
- description: Interrupt Controller List Register 3
1965
- S3_4_c12_c12_4:
1966
- name: ICH_LR4_EL2
1967
- description: Interrupt Controller List Register 4
1968
- S3_4_c12_c12_5:
1969
- name: ICH_LR5_EL2
1970
- description: Interrupt Controller List Register 5
1971
- S3_4_c12_c12_6:
1972
- name: ICH_LR6_EL2
1973
- description: Interrupt Controller List Register 6
1974
- S3_4_c12_c12_7:
1975
- name: ICH_LR7_EL2
1976
- description: Interrupt Controller List Register 7
1977
- S3_4_c12_c13_0:
1978
- name: ICH_LR8_EL2
1979
- description: Interrupt Controller List Register 8
1980
- S3_4_c12_c13_1:
1981
- name: ICH_LR9_EL2
1982
- description: Interrupt Controller List Register 9
1983
- S3_4_c12_c13_2:
1984
- name: ICH_LR10_EL2
1985
- description: Interrupt Controller List Register 10
1986
- S3_4_c12_c13_3:
1987
- name: ICH_LR11_EL2
1988
- description: Interrupt Controller List Register 11
1989
- S3_4_c12_c13_4:
1990
- name: ICH_LR12_EL2
1991
- description: Interrupt Controller List Register 12
1992
- S3_4_c12_c13_5:
1993
- name: ICH_LR13_EL2
1994
- description: Interrupt Controller List Register 13
1995
- S3_4_c12_c13_6:
1996
- name: ICH_LR14_EL2
1997
- description: Interrupt Controller List Register 14
1998
- S3_4_c12_c13_7:
1999
- name: ICH_LR15_EL2
2000
- description: Interrupt Controller List Register 15
2001
- S3_4_c13_c0_1:
2002
- name: CONTEXTIDR_EL2
2003
- description: Context ID Register (EL2)
2004
- S3_4_c13_c0_2:
2005
- name: TPIDR_EL2
2006
- description: EL2 Software Thread ID Register
2007
- S3_4_c13_c0_7:
2008
- name: SCXTNUM_EL2
2009
- description: EL2 Read/Write Software Context Number
2010
- S3_4_c13_c8_0:
2011
- name: AMEVCNTVOFF00_EL2
2012
- description: Activity Monitors Event Counter Virtual Offset Register 0 0
2013
- S3_4_c13_c8_1:
2014
- name: AMEVCNTVOFF01_EL2
2015
- description: Activity Monitors Event Counter Virtual Offset Register 0 1
2016
- S3_4_c13_c8_2:
2017
- name: AMEVCNTVOFF02_EL2
2018
- description: Activity Monitors Event Counter Virtual Offset Register 0 2
2019
- S3_4_c13_c8_3:
2020
- name: AMEVCNTVOFF03_EL2
2021
- description: Activity Monitors Event Counter Virtual Offset Register 0 3
2022
- S3_4_c13_c8_4:
2023
- name: AMEVCNTVOFF04_EL2
2024
- description: Activity Monitors Event Counter Virtual Offset Register 0 4
2025
- S3_4_c13_c8_5:
2026
- name: AMEVCNTVOFF05_EL2
2027
- description: Activity Monitors Event Counter Virtual Offset Register 0 5
2028
- S3_4_c13_c8_6:
2029
- name: AMEVCNTVOFF06_EL2
2030
- description: Activity Monitors Event Counter Virtual Offset Register 0 6
2031
- S3_4_c13_c8_7:
2032
- name: AMEVCNTVOFF07_EL2
2033
- description: Activity Monitors Event Counter Virtual Offset Register 0 7
2034
- S3_4_c13_c9_0:
2035
- name: AMEVCNTVOFF08_EL2
2036
- description: Activity Monitors Event Counter Virtual Offset Register 0 8
2037
- S3_4_c13_c9_1:
2038
- name: AMEVCNTVOFF09_EL2
2039
- description: Activity Monitors Event Counter Virtual Offset Register 0 9
2040
- S3_4_c13_c9_2:
2041
- name: AMEVCNTVOFF010_EL2
2042
- description: Activity Monitors Event Counter Virtual Offset Register 0 10
2043
- S3_4_c13_c9_3:
2044
- name: AMEVCNTVOFF011_EL2
2045
- description: Activity Monitors Event Counter Virtual Offset Register 0 11
2046
- S3_4_c13_c9_4:
2047
- name: AMEVCNTVOFF012_EL2
2048
- description: Activity Monitors Event Counter Virtual Offset Register 0 12
2049
- S3_4_c13_c9_5:
2050
- name: AMEVCNTVOFF013_EL2
2051
- description: Activity Monitors Event Counter Virtual Offset Register 0 13
2052
- S3_4_c13_c9_6:
2053
- name: AMEVCNTVOFF014_EL2
2054
- description: Activity Monitors Event Counter Virtual Offset Register 0 14
2055
- S3_4_c13_c9_7:
2056
- name: AMEVCNTVOFF015_EL2
2057
- description: Activity Monitors Event Counter Virtual Offset Register 0 15
2058
- S3_4_c13_c10_0:
2059
- name: AMEVCNTVOFF10_EL2
2060
- description: Activity Monitors Event Counter Virtual Offset Register 1 0
2061
- S3_4_c13_c10_1:
2062
- name: AMEVCNTVOFF11_EL2
2063
- description: Activity Monitors Event Counter Virtual Offset Register 1 1
2064
- S3_4_c13_c10_2:
2065
- name: AMEVCNTVOFF12_EL2
2066
- description: Activity Monitors Event Counter Virtual Offset Register 1 2
2067
- S3_4_c13_c10_3:
2068
- name: AMEVCNTVOFF13_EL2
2069
- description: Activity Monitors Event Counter Virtual Offset Register 1 3
2070
- S3_4_c13_c10_4:
2071
- name: AMEVCNTVOFF14_EL2
2072
- description: Activity Monitors Event Counter Virtual Offset Register 1 4
2073
- S3_4_c13_c10_5:
2074
- name: AMEVCNTVOFF15_EL2
2075
- description: Activity Monitors Event Counter Virtual Offset Register 1 5
2076
- S3_4_c13_c10_6:
2077
- name: AMEVCNTVOFF16_EL2
2078
- description: Activity Monitors Event Counter Virtual Offset Register 1 6
2079
- S3_4_c13_c10_7:
2080
- name: AMEVCNTVOFF17_EL2
2081
- description: Activity Monitors Event Counter Virtual Offset Register 1 7
2082
- S3_4_c13_c11_0:
2083
- name: AMEVCNTVOFF18_EL2
2084
- description: Activity Monitors Event Counter Virtual Offset Register 1 8
2085
- S3_4_c13_c11_1:
2086
- name: AMEVCNTVOFF19_EL2
2087
- description: Activity Monitors Event Counter Virtual Offset Register 1 9
2088
- S3_4_c13_c11_2:
2089
- name: AMEVCNTVOFF110_EL2
2090
- description: Activity Monitors Event Counter Virtual Offset Register 1 10
2091
- S3_4_c13_c11_3:
2092
- name: AMEVCNTVOFF111_EL2
2093
- description: Activity Monitors Event Counter Virtual Offset Register 1 11
2094
- S3_4_c13_c11_4:
2095
- name: AMEVCNTVOFF112_EL2
2096
- description: Activity Monitors Event Counter Virtual Offset Register 1 12
2097
- S3_4_c13_c11_5:
2098
- name: AMEVCNTVOFF113_EL2
2099
- description: Activity Monitors Event Counter Virtual Offset Register 1 13
2100
- S3_4_c13_c11_6:
2101
- name: AMEVCNTVOFF114_EL2
2102
- description: Activity Monitors Event Counter Virtual Offset Register 1 14
2103
- S3_4_c13_c11_7:
2104
- name: AMEVCNTVOFF115_EL2
2105
- description: Activity Monitors Event Counter Virtual Offset Register 1 15
2106
- S3_4_c14_c0_3:
2107
- name: CNTVOFF_EL2
2108
- description: Counter-timer Virtual Offset register
2109
- S3_4_c14_c0_6:
2110
- name: CNTPOFF_EL2
2111
- description: Counter-timer Physical Offset register
2112
- S3_4_c14_c1_0:
2113
- name: CNTHCTL_EL2
2114
- description: Counter-timer Hypervisor Control register
2115
- S3_4_c14_c2_0:
2116
- name: CNTHP_TVAL_EL2
2117
- description: Counter-timer Physical Timer TimerValue register (EL2)
2118
- S3_4_c14_c2_1:
2119
- name: CNTHP_CTL_EL2
2120
- description: Counter-timer Hypervisor Physical Timer Control register
2121
- S3_4_c14_c2_2:
2122
- name: CNTHP_CVAL_EL2
2123
- description: Counter-timer Physical Timer CompareValue register (EL2)
2124
- S3_4_c14_c3_0:
2125
- name: CNTHV_TVAL_EL2
2126
- description: Counter-timer Virtual Timer TimerValue Register (EL2)
2127
- S3_4_c14_c3_1:
2128
- name: CNTHV_CTL_EL2
2129
- description: Counter-timer Virtual Timer Control register (EL2)
2130
- S3_4_c14_c3_2:
2131
- name: CNTHV_CVAL_EL2
2132
- description: Counter-timer Virtual Timer CompareValue register (EL2)
2133
- S3_4_c14_c4_0:
2134
- name: CNTHVS_TVAL_EL2
2135
- description: Counter-timer Secure Virtual Timer TimerValue register (EL2)
2136
- S3_4_c14_c4_1:
2137
- name: CNTHVS_CTL_EL2
2138
- description: Counter-timer Secure Virtual Timer Control register (EL2)
2139
- S3_4_c14_c4_2:
2140
- name: CNTHVS_CVAL_EL2
2141
- description: Counter-timer Secure Virtual Timer CompareValue register (EL2)
2142
- S3_4_c14_c5_0:
2143
- name: CNTHPS_TVAL_EL2
2144
- description: Counter-timer Secure Physical Timer TimerValue register (EL2)
2145
- S3_4_c14_c5_1:
2146
- name: CNTHPS_CTL_EL2
2147
- description: Counter-timer Secure Physical Timer Control register (EL2)
2148
- S3_4_c14_c5_2:
2149
- name: CNTHPS_CVAL_EL2
2150
- description: Counter-timer Secure Physical Timer CompareValue register (EL2)
2151
- S3_6_c1_c0_0:
2152
- name: SCTLR_EL3
2153
- description: System Control Register (EL3)
2154
- S3_6_c1_c0_1:
2155
- name: ACTLR_EL3
2156
- description: Auxiliary Control Register (EL3)
2157
- S3_6_c1_c1_0:
2158
- name: SCR_EL3
2159
- description: Secure Configuration Register
2160
- S3_6_c1_c1_1:
2161
- name: SDER32_EL3
2162
- description: AArch32 Secure Debug Enable Register
2163
- S3_6_c1_c1_2:
2164
- name: CPTR_EL3
2165
- description: Architectural Feature Trap Register (EL3)
2166
- S3_6_c1_c2_0:
2167
- name: ZCR_EL3
2168
- description: SVE Control Register for EL3
2169
- S3_6_c1_c3_1:
2170
- name: MDCR_EL3
2171
- description: Monitor Debug Configuration Register (EL3)
2172
- S3_6_c2_c0_0:
2173
- name: TTBR0_EL3
2174
- description: Translation Table Base Register 0 (EL3)
2175
- S3_6_c2_c0_2:
2176
- name: TCR_EL3
2177
- description: Translation Control Register (EL3)
2178
- S3_6_c4_c0_0:
2179
- name: SPSR_EL3
2180
- description: Saved Program Status Register (EL3)
2181
- S3_6_c4_c0_1:
2182
- name: ELR_EL3
2183
- description: Exception Link Register (EL3)
2184
- S3_6_c4_c1_0:
2185
- name: SP_EL2
2186
- description: Stack Pointer (EL2)
2187
- S3_6_c5_c1_0:
2188
- name: AFSR0_EL3
2189
- description: Auxiliary Fault Status Register 0 (EL3)
2190
- S3_6_c5_c1_1:
2191
- name: AFSR1_EL3
2192
- description: Auxiliary Fault Status Register 1 (EL3)
2193
- S3_6_c5_c2_0:
2194
- name: ESR_EL3
2195
- description: Exception Syndrome Register (EL3)
2196
- S3_6_c5_c6_0:
2197
- name: TFSR_EL3
2198
- description: Tag Fault Status Register (EL3)
2199
- S3_6_c6_c0_0:
2200
- name: FAR_EL3
2201
- description: Fault Address Register (EL3)
2202
- S3_6_c10_c2_0:
2203
- name: MAIR_EL3
2204
- description: Memory Attribute Indirection Register (EL3)
2205
- S3_6_c10_c3_0:
2206
- name: AMAIR_EL3
2207
- description: Auxiliary Memory Attribute Indirection Register (EL3)
2208
- S3_6_c10_c5_0:
2209
- name: MPAM3_EL3
2210
- description: MPAM3 Register (EL3)
2211
- S3_6_c12_c0_0:
2212
- name: VBAR_EL3
2213
- description: Vector Base Address Register (EL3)
2214
- S3_6_c12_c0_1:
2215
- name: RVBAR_EL3
2216
- description: Reset Vector Base Address Register (if EL3 implemented)
2217
- S3_6_c12_c0_2:
2218
- name: RMR_EL3
2219
- description: Reset Management Register (EL3)
2220
- S3_6_c12_c12_4:
2221
- name: ICC_CTLR_EL3
2222
- description: Interrupt Controller Control Register (EL3)
2223
- S3_6_c12_c12_5:
2224
- name: ICC_SRE_EL3
2225
- description: Interrupt Controller System Register Enable register (EL3)
2226
- S3_6_c12_c12_7:
2227
- name: ICC_IGRPEN1_EL3
2228
- description: Interrupt Controller Interrupt Group 1 Enable register (EL3)
2229
- S3_6_c13_c0_2:
2230
- name: TPIDR_EL3
2231
- description: EL3 Software Thread ID Register
2232
- S3_6_c13_c0_7:
2233
- name: SCXTNUM_EL3
2234
- description: EL3 Read/Write Software Context Number
2235
- S3_7_c14_c2_0:
2236
- name: CNTPS_TVAL_EL1
2237
- description: Counter-timer Physical Secure Timer TimerValue register
2238
- S3_7_c14_c2_1:
2239
- name: CNTPS_CTL_EL1
2240
- description: Counter-timer Physical Secure Timer Control register
2241
- S3_7_c14_c2_2:
2242
- name: CNTPS_CVAL_EL1
2243
- description: Counter-timer Physical Secure Timer CompareValue register
2244
12
  apple_system_registers:
2245
13
  S3_0_c15_c0_0:
2246
14
  name: HID0
@@ -7575,3 +5343,2240 @@ aarch64:
7575
5343
  el1:
7576
5344
  name: UPMECM3_EL1
7577
5345
  description:
5346
+ msr:
5347
+ tpidr_el1:
5348
+ name: TPIDR_EL1
5349
+ description: Thread ID, Privileged
5350
+ ttbr1_el1:
5351
+ name: TTBR1_EL1
5352
+ description: Translation Table Base Register 1
5353
+ ttbr0_el1:
5354
+ name: TTBR0_EL1
5355
+ description: Translation Table Base Register 0
5356
+ mpidr_el1:
5357
+ name: MPIDR_EL1
5358
+ description: MultiProcessor Affinity Register
5359
+ clidr_el1:
5360
+ name: CLIDR_EL1
5361
+ description: Cache Level ID Register
5362
+ csselr_el1:
5363
+ name: CSSELR_EL1
5364
+ description: Cache Size Selection Register
5365
+ sctlr_el1:
5366
+ name: SCTLR_EL1
5367
+ description: System Control Register
5368
+ actlr_el1:
5369
+ name: ACTLR_EL1
5370
+ description: Auxiliary Control Register
5371
+ cpacr_el1:
5372
+ name: CPACR_EL1
5373
+ description: Coprocessor Access Control
5374
+ zcr_el1:
5375
+ name: ZCR_EL1
5376
+ description: SVE Control
5377
+ tcr_el1:
5378
+ name: TCR_EL1
5379
+ description: Translation Control Register
5380
+ tcr2_el1:
5381
+ name: TCL2_EL1
5382
+ description: Extended Translation Control Register
5383
+ esr_el1:
5384
+ name: ESL_EL1
5385
+ description: Exception Syndrome Register
5386
+ afsr0_el1:
5387
+ name: AFSR0_EL1
5388
+ description: Auxiliary Fault Status Register 0
5389
+ afsr1_el1:
5390
+ name: AFSR1_EL1
5391
+ description: Auxiliary Fault Status Register 1
5392
+ far_el1:
5393
+ name: FAR_EL1
5394
+ description: Fault Address Register
5395
+ mair_el1:
5396
+ name: MAIR_EL1
5397
+ description: Memory Attribute Indirection Register
5398
+ vbar_el1:
5399
+ name: VBAR_EL1
5400
+ description: Vector Base Address Register
5401
+ contextidr_el1:
5402
+ name: CONTEXTIDR_EL1
5403
+ description: Context ID Register
5404
+ tpidr_el0:
5405
+ name: TPIDR_EL0
5406
+ description: Thread ID, User R/W
5407
+ S1_0_c7_c1_0:
5408
+ name: IC IALLUIS
5409
+ description: Instruction Cache Invalidate All to PoU, Inner Shareable
5410
+ S1_0_c7_c5_0:
5411
+ name: IC IALLU
5412
+ description: Instruction Cache Invalidate All to PoU
5413
+ S1_0_c7_c6_1:
5414
+ name: DC IVAC
5415
+ description: Data or unified Cache line Invalidate by VA to PoC
5416
+ S1_0_c7_c6_2:
5417
+ name: DC ISW
5418
+ description: Data or unified Cache line Invalidate by Set/Way
5419
+ S1_0_c7_c6_3:
5420
+ name: DC IGVAC
5421
+ description: Data, Allocation Tag or unified Cache line Invalidate of Allocation
5422
+ Tags by VA to PoC
5423
+ S1_0_c7_c6_4:
5424
+ name: DC IGSW
5425
+ description: Data, Allocation Tag or unified Cache line Invalidate of Allocation
5426
+ Tags by Set/Way
5427
+ S1_0_c7_c6_5:
5428
+ name: DC IGDVAC
5429
+ description: Data, Allocation Tag or unified Cache line Invalidate of Allocation
5430
+ Tags by VA to PoC
5431
+ S1_0_c7_c6_6:
5432
+ name: DC IGDSW
5433
+ description: Data, Allocation Tag or unified Cache line Invalidate of Data and
5434
+ Allocation Tags by Set/Way
5435
+ S1_0_c7_c8_0:
5436
+ name: AT S1E1R
5437
+ description: Address Translate Stage 1 EL1 Read
5438
+ S1_0_c7_c8_1:
5439
+ name: AT S1E1W
5440
+ description: Address Translate Stage 1 EL1 Write
5441
+ S1_0_c7_c8_2:
5442
+ name: AT S1E0R
5443
+ description: Address Translate Stage 1 EL0 Read
5444
+ S1_0_c7_c8_3:
5445
+ name: AT S1E0W
5446
+ description: Address Translate Stage 1 EL0 Write
5447
+ S1_0_c7_c9_0:
5448
+ name: AT S1E1RP
5449
+ description: Address Translate Stage 1 EL1 Read PAN
5450
+ S1_0_c7_c9_1:
5451
+ name: AT S1E1WP
5452
+ description: Address Translate Stage 1 EL1 Write PAN
5453
+ S1_0_c7_c10_2:
5454
+ name: DC CSW
5455
+ description: Data or unified Cache line Clean by Set/Way
5456
+ S1_0_c7_c10_4:
5457
+ name: DC CGSW
5458
+ description: Data, Allocation Tag or unified Cache line Clean of Allocation
5459
+ Tags by Set/Way
5460
+ S1_0_c7_c10_6:
5461
+ name: DC CGDSW
5462
+ description: Data, Allocation Tag or unified Cache line Clean of Data and Allocation
5463
+ Tags by Set/Way
5464
+ S1_0_c7_c14_2:
5465
+ name: DC CISW
5466
+ description: Data or unified Cache line Clean and Invalidate by Set/Way
5467
+ S1_0_c7_c14_4:
5468
+ name: DC CIGSW
5469
+ description: Data, Allocation Tag or unified Cache line Clean and Invalidate
5470
+ of Allocation Tags by Set/Way
5471
+ S1_0_c7_c14_6:
5472
+ name: DC CIGDSW
5473
+ description: Data, Allocation Tag or unified Cache line Clean and Invalidate
5474
+ of Data and Allocation Tags by Set/Way
5475
+ S1_0_c8_c1_0:
5476
+ name: TLBI VMALLE1OS
5477
+ description: TLB Invalidate by VMID, All at stage 1, EL1, Outer Shareable
5478
+ S1_0_c8_c1_1:
5479
+ name: TLBI VAE1OS
5480
+ description: TLB Invalidate by VA, EL1, Outer Shareable
5481
+ S1_0_c8_c1_2:
5482
+ name: TLBI ASIDE1OS
5483
+ description: TLB Invalidate by ASID, EL1, Outer Shareable
5484
+ S1_0_c8_c1_3:
5485
+ name: TLBI VAAE1OS
5486
+ description: TLB Invalidate by VA, All ASID, EL1, Outer Shareable
5487
+ S1_0_c8_c1_5:
5488
+ name: TLBI VALE1OS
5489
+ description: TLB Invalidate by VA, Last level, EL1, Outer Shareable
5490
+ S1_0_c8_c1_7:
5491
+ name: TLBI VAALE1OS
5492
+ description: TLB Invalidate by VA, All ASID, Last Level, EL1, Outer Shareable
5493
+ S1_0_c8_c2_1:
5494
+ name: TLBI RVAE1IS
5495
+ description: TLB Range Invalidate by VA, EL1, Inner Shareable
5496
+ S1_0_c8_c2_3:
5497
+ name: TLBI RVAAE1IS
5498
+ description: TLB Range Invalidate by VA, All ASID, EL1, Inner Shareable
5499
+ S1_0_c8_c2_5:
5500
+ name: TLBI RVALE1IS
5501
+ description: TLB Range Invalidate by VA, Last level, EL1, Inner Shareable
5502
+ S1_0_c8_c2_7:
5503
+ name: TLBI RVAALE1IS
5504
+ description: TLB Range Invalidate by VA, All ASID, Last Level, EL1, Inner Shareable
5505
+ S1_0_c8_c3_0:
5506
+ name: TLBI VMALLE1IS
5507
+ description: TLB Invalidate by VMID, All at stage 1, EL1, Inner Shareable
5508
+ S1_0_c8_c3_1:
5509
+ name: TLBI VAE1IS
5510
+ description: TLB Invalidate by VA, EL1, Inner Shareable
5511
+ S1_0_c8_c3_2:
5512
+ name: TLBI ASIDE1IS
5513
+ description: TLB Invalidate by ASID, EL1, Inner Shareable
5514
+ S1_0_c8_c3_3:
5515
+ name: TLBI VAAE1IS
5516
+ description: TLB Invalidate by VA, All ASID, EL1, Inner Shareable
5517
+ S1_0_c8_c3_5:
5518
+ name: TLBI VALE1IS
5519
+ description: TLB Invalidate by VA, Last level, EL1, Inner Shareable
5520
+ S1_0_c8_c3_7:
5521
+ name: TLBI VAALE1IS
5522
+ description: TLB Invalidate by VA, All ASID, Last Level, EL1, Inner Shareable
5523
+ S1_0_c8_c5_1:
5524
+ name: TLBI RVAE1OS
5525
+ description: TLB Range Invalidate by VA, EL1, Outer Shareable
5526
+ S1_0_c8_c5_3:
5527
+ name: TLBI RVAAE1OS
5528
+ description: TLB Range Invalidate by VA, All ASID, EL1, Outer Shareable
5529
+ S1_0_c8_c5_5:
5530
+ name: TLBI RVALE1OS
5531
+ description: TLB Range Invalidate by VA, Last level, EL1, Outer Shareable
5532
+ S1_0_c8_c5_7:
5533
+ name: TLBI RVAALE1OS
5534
+ description: TLB Range Invalidate by VA, All ASID, Last Level, EL1, Outer Shareable
5535
+ S1_0_c8_c6_1:
5536
+ name: TLBI RVAE1
5537
+ description: TLB Range Invalidate by VA, EL1
5538
+ S1_0_c8_c6_3:
5539
+ name: TLBI RVAAE1
5540
+ description: TLB Range Invalidate by VA, All ASID, EL1
5541
+ S1_0_c8_c6_5:
5542
+ name: TLBI RVALE1
5543
+ description: TLB Range Invalidate by VA, Last level, EL1
5544
+ S1_0_c8_c6_7:
5545
+ name: TLBI RVAALE1
5546
+ description: TLB Range Invalidate by VA, All ASID, Last level, EL1
5547
+ S1_0_c8_c7_0:
5548
+ name: TLBI VMALLE1
5549
+ description: TLB Invalidate by VMID, All at stage 1, EL1
5550
+ S1_0_c8_c7_1:
5551
+ name: TLBI VAE1
5552
+ description: TLB Invalidate by VA, EL1
5553
+ S1_0_c8_c7_2:
5554
+ name: TLBI ASIDE1
5555
+ description: TLB Invalidate by ASID, EL1
5556
+ S1_0_c8_c7_3:
5557
+ name: TLBI VAAE1
5558
+ description: TLB Invalidate by VA, All ASID, EL1
5559
+ S1_0_c8_c7_5:
5560
+ name: TLBI VALE1
5561
+ description: TLB Invalidate by VA, Last level, EL1
5562
+ S1_0_c8_c7_7:
5563
+ name: TLBI VAALE1
5564
+ description: TLB Invalidate by VA, All ASID, Last level, EL1
5565
+ S1_3_c7_c3_4:
5566
+ name: CFP RCTX
5567
+ description: Control Flow Prediction Restriction by Context
5568
+ S1_3_c7_c3_5:
5569
+ name: DVP RCTX
5570
+ description: Data Value Prediction Restriction by Context
5571
+ S1_3_c7_c3_7:
5572
+ name: CPP RCTX
5573
+ description: Cache Prefetch Prediction Restriction by Context
5574
+ S1_3_c7_c4_1:
5575
+ name: DC ZVA
5576
+ description: Data Cache Zero by VA
5577
+ S1_3_c7_c4_3:
5578
+ name: DC GVA
5579
+ description: Data Cache set Allocation Tag by VA
5580
+ S1_3_c7_c4_4:
5581
+ name: DC GZVA
5582
+ description: Data Cache set Allocation Tags and Zero by VA
5583
+ S1_3_c7_c5_1:
5584
+ name: IC IVAU
5585
+ description: Instruction Cache line Invalidate by VA to PoU
5586
+ S1_3_c7_c10_1:
5587
+ name: DC CVAC
5588
+ description: Data or unified Cache line Clean by VA to PoC
5589
+ S1_3_c7_c10_3:
5590
+ name: DC CGVAC
5591
+ description: Data, Allocation Tag or unified Cache line Clean of Allocation
5592
+ Tags by VA to PoC
5593
+ S1_3_c7_c10_5:
5594
+ name: DC CGDVAC
5595
+ description: Data, Allocation Tag or unified Cache line Clean of Allocation
5596
+ Tags by VA to PoC
5597
+ S1_3_c7_c11_1:
5598
+ name: DC CVAU
5599
+ description: Data or unified Cache line Clean by VA to PoU
5600
+ S1_3_c7_c12_1:
5601
+ name: DC CVAP
5602
+ description: Data or unified Cache line Clean by VA to PoP
5603
+ S1_3_c7_c12_3:
5604
+ name: DC CGVAP
5605
+ description: Data, Allocation Tag or unified Cache line Clean of Allocation
5606
+ Tags by VA to PoP
5607
+ S1_3_c7_c12_5:
5608
+ name: DC CGDVAP
5609
+ description: Data, Allocation Tag or unified Cache line Clean of Data and Allocation
5610
+ Tags by VA to PoP
5611
+ S1_3_c7_c13_1:
5612
+ name: DC CVADP
5613
+ description: Data or unified Cache line Clean by VA to PoDP
5614
+ S1_3_c7_c13_3:
5615
+ name: DC CGVADP
5616
+ description: Clean of Allocation Tags by VA to PoDP
5617
+ S1_3_c7_c13_5:
5618
+ name: DC CGDVADP
5619
+ description: Data, Allocation Tag or unified Cache line Clean of Allocation
5620
+ Tags by VA to PoDP
5621
+ S1_3_c7_c14_1:
5622
+ name: DC CIVAC
5623
+ description: Data or unified Cache line Clean and Invalidate by VA to PoC
5624
+ S1_3_c7_c14_3:
5625
+ name: DC CIGVAC
5626
+ description: Data, Allocation Tag or unified Cache line Clean and Invalidate
5627
+ of Allocation Tags by VA to PoC
5628
+ S1_3_c7_c14_5:
5629
+ name: DC CIGDVAC
5630
+ description: Data, Allocation Tag or unified Cache line Clean and Invalidate
5631
+ of Data and Allocation Tags by VA to PoC
5632
+ S1_4_c7_c8_0:
5633
+ name: AT S1E2R
5634
+ description: Address Translate Stage 1 EL2 Read
5635
+ S1_4_c7_c8_1:
5636
+ name: AT S1E2W
5637
+ description: Address Translate Stage 1 EL2 Write
5638
+ S1_4_c7_c8_4:
5639
+ name: AT S12E1R
5640
+ description: Address Translate Stages 1 and 2 EL1 Read
5641
+ S1_4_c7_c8_5:
5642
+ name: AT S12E1W
5643
+ description: Address Translate Stages 1 and 2 EL1 Write
5644
+ S1_4_c7_c8_6:
5645
+ name: AT S12E0R
5646
+ description: Address Translate Stages 1 and 2 EL0 Read
5647
+ S1_4_c7_c8_7:
5648
+ name: AT S12E0W
5649
+ description: Address Translate Stages 1 and 2 EL0 Write
5650
+ S1_4_c8_c0_1:
5651
+ name: TLBI IPAS2E1IS
5652
+ description: TLB Invalidate by Intermediate Physical Address, Stage 2, EL1,
5653
+ Inner Shareable
5654
+ S1_4_c8_c0_2:
5655
+ name: TLBI RIPAS2E1IS
5656
+ description: TLB Range Invalidate by Intermediate Physical Address, Stage 2,
5657
+ EL1, Inner Shareable
5658
+ S1_4_c8_c0_5:
5659
+ name: TLBI IPAS2LE1IS
5660
+ description: TLB Invalidate by Intermediate Physical Address, Stage 2, Last
5661
+ level, EL1, Inner Shareable
5662
+ S1_4_c8_c0_6:
5663
+ name: TLBI RIPAS2LE1IS
5664
+ description: TLB Range Invalidate by Intermediate Physical Address, Stage 2,
5665
+ Last level, EL1, Inner Shareable
5666
+ S1_4_c8_c1_0:
5667
+ name: TLBI ALLE2OS
5668
+ description: TLB Invalidate All, EL2, Outer Shareable
5669
+ S1_4_c8_c1_1:
5670
+ name: TLBI VAE2OS
5671
+ description: TLB Invalidate by VA, EL2, Outer Shareable
5672
+ S1_4_c8_c1_4:
5673
+ name: TLBI ALLE1OS
5674
+ description: TLB Invalidate All, EL1, Outer Shareable
5675
+ S1_4_c8_c1_5:
5676
+ name: TLBI VALE2OS
5677
+ description: TLB Invalidate by VA, Last level, EL2, Outer Shareable
5678
+ S1_4_c8_c1_6:
5679
+ name: TLBI VMALLS12E1OS
5680
+ description: TLB Invalidate by VMID, All at Stage 1 and 2, EL1, Outer Shareable
5681
+ S1_4_c8_c2_1:
5682
+ name: TLBI RVAE2IS
5683
+ description: TLB Range Invalidate by VA, EL2, Inner Shareable
5684
+ S1_4_c8_c2_5:
5685
+ name: TLBI RVALE2IS
5686
+ description: TLB Range Invalidate by VA, Last level, EL2, Inner Shareable
5687
+ S1_4_c8_c3_0:
5688
+ name: TLBI ALLE2IS
5689
+ description: TLB Invalidate All, EL2, Inner Shareable
5690
+ S1_4_c8_c3_1:
5691
+ name: TLBI VAE2IS
5692
+ description: TLB Invalidate by VA, EL2, Inner Shareable
5693
+ S1_4_c8_c3_4:
5694
+ name: TLBI ALLE1IS
5695
+ description: TLB Invalidate All, EL1, Inner Shareable
5696
+ S1_4_c8_c3_5:
5697
+ name: TLBI VALE2IS
5698
+ description: TLB Invalidate by VA, Last level, EL2, Inner Shareable
5699
+ S1_4_c8_c3_6:
5700
+ name: TLBI VMALLS12E1IS
5701
+ description: TLB Invalidate by VMID, All at Stage 1 and 2, EL1, Inner Shareable
5702
+ S1_4_c8_c4_0:
5703
+ name: TLBI IPAS2E1OS
5704
+ description: TLB Invalidate by Intermediate Physical Address, Stage 2, EL1,
5705
+ Outer Shareable
5706
+ S1_4_c8_c4_1:
5707
+ name: TLBI IPAS2E1
5708
+ description: TLB Invalidate by Intermediate Physical Address, Stage 2, EL1
5709
+ S1_4_c8_c4_2:
5710
+ name: TLBI RIPAS2E1
5711
+ description: TLB Range Invalidate by Intermediate Physical Address, Stage 2,
5712
+ EL1
5713
+ S1_4_c8_c4_3:
5714
+ name: TLBI RIPAS2E1OS
5715
+ description: TLB Range Invalidate by Intermediate Physical Address, Stage 2,
5716
+ EL1, Outer Shareable
5717
+ S1_4_c8_c4_4:
5718
+ name: TLBI IPAS2LE1OS
5719
+ description: TLB Invalidate by Intermediate Physical Address, Stage 2, Last
5720
+ level, EL1, Outer Shareable
5721
+ S1_4_c8_c4_5:
5722
+ name: TLBI IPAS2LE1
5723
+ description: TLB Invalidate by Intermediate Physical Address, Stage 2, Last
5724
+ level, EL1
5725
+ S1_4_c8_c4_6:
5726
+ name: TLBI RIPAS2LE1
5727
+ description: TLB Range Invalidate by Intermediate Physical Address, Stage 2,
5728
+ Last level, EL1
5729
+ S1_4_c8_c4_7:
5730
+ name: TLBI RIPAS2LE1OS
5731
+ description: TLB Range Invalidate by Intermediate Physical Address, Stage 2,
5732
+ Last level, EL1, Outer Shareable
5733
+ S1_4_c8_c5_1:
5734
+ name: TLBI RVAE2OS
5735
+ description: TLB Range Invalidate by VA, EL2, Outer Shareable
5736
+ S1_4_c8_c5_5:
5737
+ name: TLBI RVALE2OS
5738
+ description: TLB Range Invalidate by VA, Last level, EL2, Outer Shareable
5739
+ S1_4_c8_c6_1:
5740
+ name: TLBI RVAE2
5741
+ description: TLB Range Invalidate by VA, EL2
5742
+ S1_4_c8_c6_5:
5743
+ name: TLBI RVALE2
5744
+ description: TLB Range Invalidate by VA, Last level, EL2
5745
+ S1_4_c8_c7_0:
5746
+ name: TLBI ALLE2
5747
+ description: TLB Invalidate All, EL2
5748
+ S1_4_c8_c7_1:
5749
+ name: TLBI VAE2
5750
+ description: TLB Invalidate by VA, EL2
5751
+ S1_4_c8_c7_4:
5752
+ name: TLBI ALLE1
5753
+ description: TLB Invalidate All, EL1
5754
+ S1_4_c8_c7_5:
5755
+ name: TLBI VALE2
5756
+ description: TLB Invalidate by VA, Last level, EL2
5757
+ S1_4_c8_c7_6:
5758
+ name: TLBI VMALLS12E1
5759
+ description: TLB Invalidate by VMID, All at Stage 1 and 2, EL1
5760
+ S1_6_c7_c8_0:
5761
+ name: AT S1E3R
5762
+ description: Address Translate Stage 1 EL3 Read
5763
+ S1_6_c7_c8_1:
5764
+ name: AT S1E3W
5765
+ description: Address Translate Stage 1 EL3 Write
5766
+ S1_6_c8_c1_0:
5767
+ name: TLBI ALLE3OS
5768
+ description: TLB Invalidate All, EL3, Outer Shareable
5769
+ S1_6_c8_c1_1:
5770
+ name: TLBI VAE3OS
5771
+ description: TLB Invalidate by VA, EL3, Outer Shareable
5772
+ S1_6_c8_c1_5:
5773
+ name: TLBI VALE3OS
5774
+ description: TLB Invalidate by VA, Last level, EL3, Outer Shareable
5775
+ S1_6_c8_c2_1:
5776
+ name: TLBI RVAE3IS
5777
+ description: TLB Range Invalidate by VA, EL3, Inner Shareable
5778
+ S1_6_c8_c2_5:
5779
+ name: TLBI RVALE3IS
5780
+ description: TLB Range Invalidate by VA, Last level, EL3, Inner Shareable
5781
+ S1_6_c8_c3_0:
5782
+ name: TLBI ALLE3IS
5783
+ description: TLB Invalidate All, EL3, Inner Shareable
5784
+ S1_6_c8_c3_1:
5785
+ name: TLBI VAE3IS
5786
+ description: TLB Invalidate by VA, EL3, Inner Shareable
5787
+ S1_6_c8_c3_5:
5788
+ name: TLBI VALE3IS
5789
+ description: TLB Invalidate by VA, Last level, EL3, Inner Shareable
5790
+ S1_6_c8_c5_1:
5791
+ name: TLBI RVAE3OS
5792
+ description: TLB Range Invalidate by VA, EL3, Outer Shareable
5793
+ S1_6_c8_c5_5:
5794
+ name: TLBI RVALE3OS
5795
+ description: TLB Range Invalidate by VA, Last level, EL3, Outer Shareable
5796
+ S1_6_c8_c6_1:
5797
+ name: TLBI RVAE3
5798
+ description: TLB Range Invalidate by VA, EL3
5799
+ S1_6_c8_c6_5:
5800
+ name: TLBI RVALE3
5801
+ description: TLB Range Invalidate by VA, Last level, EL3
5802
+ S1_6_c8_c7_0:
5803
+ name: TLBI ALLE3
5804
+ description: TLB Invalidate All, EL3
5805
+ S1_6_c8_c7_1:
5806
+ name: TLBI VAE3
5807
+ description: TLB Invalidate by VA, EL3
5808
+ S1_6_c8_c7_5:
5809
+ name: TLBI VALE3
5810
+ description: TLB Invalidate by VA, Last level, EL3
5811
+ S2_0_c0_c0_2:
5812
+ name: OSDTRRX_EL1
5813
+ description: OS Lock Data Transfer Register, Receive
5814
+ S2_0_c0_c0_4:
5815
+ name: DBGBVR0_EL1
5816
+ description: Debug Breakpoint Value Register 0
5817
+ S2_0_c0_c0_5:
5818
+ name: DBGBCR0_EL1
5819
+ description: Debug Breakpoint Control Register 0
5820
+ S2_0_c0_c0_6:
5821
+ name: DBGWVR0_EL1
5822
+ description: Debug Watchpoint Value Register 0
5823
+ S2_0_c0_c0_7:
5824
+ name: DBGWCR0_EL1
5825
+ description: Debug Watchpoint Control Register 0
5826
+ S2_0_c0_c1_4:
5827
+ name: DBGBVR1_EL1
5828
+ description: Debug Breakpoint Value Register 1
5829
+ S2_0_c0_c1_5:
5830
+ name: DBGBCR1_EL1
5831
+ description: Debug Breakpoint Control Register 1
5832
+ S2_0_c0_c1_6:
5833
+ name: DBGWVR1_EL1
5834
+ description: Debug Watchpoint Value Register 1
5835
+ S2_0_c0_c1_7:
5836
+ name: DBGWCR1_EL1
5837
+ description: Debug Watchpoint Control Register 1
5838
+ S2_0_c0_c2_0:
5839
+ name: MDCCINT_EL1
5840
+ description: Monitor DCC Interrupt Enable Register
5841
+ S2_0_c0_c2_2:
5842
+ name: MDSCR_EL1
5843
+ description: Monitor Debug System Control Register
5844
+ S2_0_c0_c2_4:
5845
+ name: DBGBVR2_EL1
5846
+ description: Debug Breakpoint Value Register 2
5847
+ S2_0_c0_c2_5:
5848
+ name: DBGBCR2_EL1
5849
+ description: Debug Breakpoint Control Register 2
5850
+ S2_0_c0_c2_6:
5851
+ name: DBGWVR2_EL1
5852
+ description: Debug Watchpoint Value Register 2
5853
+ S2_0_c0_c2_7:
5854
+ name: DBGWCR2_EL1
5855
+ description: Debug Watchpoint Control Register 2
5856
+ S2_0_c0_c3_2:
5857
+ name: OSDTRTX_EL1
5858
+ description: OS Lock Data Transfer Register, Transmit
5859
+ S2_0_c0_c3_4:
5860
+ name: DBGBVR3_EL1
5861
+ description: Debug Breakpoint Value Register 3
5862
+ S2_0_c0_c3_5:
5863
+ name: DBGBCR3_EL1
5864
+ description: Debug Breakpoint Control Register 3
5865
+ S2_0_c0_c3_6:
5866
+ name: DBGWVR3_EL1
5867
+ description: Debug Watchpoint Value Register 3
5868
+ S2_0_c0_c3_7:
5869
+ name: DBGWCR3_EL1
5870
+ description: Debug Watchpoint Control Register 3
5871
+ S2_0_c0_c4_4:
5872
+ name: DBGBVR4_EL1
5873
+ description: Debug Breakpoint Value Register 4
5874
+ S2_0_c0_c4_5:
5875
+ name: DBGBCR4_EL1
5876
+ description: Debug Breakpoint Control Register 4
5877
+ S2_0_c0_c4_6:
5878
+ name: DBGWVR4_EL1
5879
+ description: Debug Watchpoint Value Register 4
5880
+ S2_0_c0_c4_7:
5881
+ name: DBGWCR4_EL1
5882
+ description: Debug Watchpoint Control Register 4
5883
+ S2_0_c0_c5_4:
5884
+ name: DBGBVR5_EL1
5885
+ description: Debug Breakpoint Value Register 5
5886
+ S2_0_c0_c5_5:
5887
+ name: DBGBCR5_EL1
5888
+ description: Debug Breakpoint Control Register 5
5889
+ S2_0_c0_c5_6:
5890
+ name: DBGWVR5_EL1
5891
+ description: Debug Watchpoint Value Register 5
5892
+ S2_0_c0_c5_7:
5893
+ name: DBGWCR5_EL1
5894
+ description: Debug Watchpoint Control Register 5
5895
+ S2_0_c0_c6_2:
5896
+ name: OSECCR_EL1
5897
+ description: OS Lock Exception Catch Control Register
5898
+ S2_0_c0_c6_4:
5899
+ name: DBGBVR6_EL1
5900
+ description: Debug Breakpoint Value Register 6
5901
+ S2_0_c0_c6_5:
5902
+ name: DBGBCR6_EL1
5903
+ description: Debug Breakpoint Control Register 6
5904
+ S2_0_c0_c6_6:
5905
+ name: DBGWVR6_EL1
5906
+ description: Debug Watchpoint Value Register 6
5907
+ S2_0_c0_c6_7:
5908
+ name: DBGWCR6_EL1
5909
+ description: Debug Watchpoint Control Register 6
5910
+ S2_0_c0_c7_4:
5911
+ name: DBGBVR7_EL1
5912
+ description: Debug Breakpoint Value Register 7
5913
+ S2_0_c0_c7_5:
5914
+ name: DBGBCR7_EL1
5915
+ description: Debug Breakpoint Control Register 7
5916
+ S2_0_c0_c7_6:
5917
+ name: DBGWVR7_EL1
5918
+ description: Debug Watchpoint Value Register 7
5919
+ S2_0_c0_c7_7:
5920
+ name: DBGWCR7_EL1
5921
+ description: Debug Watchpoint Control Register 7
5922
+ S2_0_c0_c8_4:
5923
+ name: DBGBVR8_EL1
5924
+ description: Debug Breakpoint Value Register 8
5925
+ S2_0_c0_c8_5:
5926
+ name: DBGBCR8_EL1
5927
+ description: Debug Breakpoint Control Register 8
5928
+ S2_0_c0_c8_6:
5929
+ name: DBGWVR8_EL1
5930
+ description: Debug Watchpoint Value Register 8
5931
+ S2_0_c0_c8_7:
5932
+ name: DBGWCR8_EL1
5933
+ description: Debug Watchpoint Control Register 8
5934
+ S2_0_c0_c9_4:
5935
+ name: DBGBVR9_EL1
5936
+ description: Debug Breakpoint Value Register 9
5937
+ S2_0_c0_c9_5:
5938
+ name: DBGBCR9_EL1
5939
+ description: Debug Breakpoint Control Register 9
5940
+ S2_0_c0_c9_6:
5941
+ name: DBGWVR9_EL1
5942
+ description: Debug Watchpoint Value Register 9
5943
+ S2_0_c0_c9_7:
5944
+ name: DBGWCR9_EL1
5945
+ description: Debug Watchpoint Control Register 9
5946
+ S2_0_c0_c10_4:
5947
+ name: DBGBVR10_EL1
5948
+ description: Debug Breakpoint Value Register 10
5949
+ S2_0_c0_c10_5:
5950
+ name: DBGBCR10_EL1
5951
+ description: Debug Breakpoint Control Register 10
5952
+ S2_0_c0_c10_6:
5953
+ name: DBGWVR10_EL1
5954
+ description: Debug Watchpoint Value Register 10
5955
+ S2_0_c0_c10_7:
5956
+ name: DBGWCR10_EL1
5957
+ description: Debug Watchpoint Control Register 10
5958
+ S2_0_c0_c11_4:
5959
+ name: DBGBVR11_EL1
5960
+ description: Debug Breakpoint Value Register 11
5961
+ S2_0_c0_c11_5:
5962
+ name: DBGBCR11_EL1
5963
+ description: Debug Breakpoint Control Register 11
5964
+ S2_0_c0_c11_6:
5965
+ name: DBGWVR11_EL1
5966
+ description: Debug Watchpoint Value Register 11
5967
+ S2_0_c0_c11_7:
5968
+ name: DBGWCR11_EL1
5969
+ description: Debug Watchpoint Control Register 11
5970
+ S2_0_c0_c12_4:
5971
+ name: DBGBVR12_EL1
5972
+ description: Debug Breakpoint Value Register 12
5973
+ S2_0_c0_c12_5:
5974
+ name: DBGBCR12_EL1
5975
+ description: Debug Breakpoint Control Register 12
5976
+ S2_0_c0_c12_6:
5977
+ name: DBGWVR12_EL1
5978
+ description: Debug Watchpoint Value Register 12
5979
+ S2_0_c0_c12_7:
5980
+ name: DBGWCR12_EL1
5981
+ description: Debug Watchpoint Control Register 12
5982
+ S2_0_c0_c13_4:
5983
+ name: DBGBVR13_EL1
5984
+ description: Debug Breakpoint Value Register 13
5985
+ S2_0_c0_c13_5:
5986
+ name: DBGBCR13_EL1
5987
+ description: Debug Breakpoint Control Register 13
5988
+ S2_0_c0_c13_6:
5989
+ name: DBGWVR13_EL1
5990
+ description: Debug Watchpoint Value Register 13
5991
+ S2_0_c0_c13_7:
5992
+ name: DBGWCR13_EL1
5993
+ description: Debug Watchpoint Control Register 13
5994
+ S2_0_c0_c14_4:
5995
+ name: DBGBVR14_EL1
5996
+ description: Debug Breakpoint Value Register 14
5997
+ S2_0_c0_c14_5:
5998
+ name: DBGBCR14_EL1
5999
+ description: Debug Breakpoint Control Register 14
6000
+ S2_0_c0_c14_6:
6001
+ name: DBGWVR14_EL1
6002
+ description: Debug Watchpoint Value Register 14
6003
+ S2_0_c0_c14_7:
6004
+ name: DBGWCR14_EL1
6005
+ description: Debug Watchpoint Control Register 14
6006
+ S2_0_c0_c15_4:
6007
+ name: DBGBVR15_EL1
6008
+ description: Debug Breakpoint Value Register 15
6009
+ S2_0_c0_c15_5:
6010
+ name: DBGBCR15_EL1
6011
+ description: Debug Breakpoint Control Register 15
6012
+ S2_0_c0_c15_6:
6013
+ name: DBGWVR15_EL1
6014
+ description: Debug Watchpoint Value Register 15
6015
+ S2_0_c0_c15_7:
6016
+ name: DBGWCR15_EL1
6017
+ description: Debug Watchpoint Control Register 15
6018
+ S2_0_c1_c0_0:
6019
+ name: MDRAR_EL1
6020
+ description: Monitor Debug ROM Address Register
6021
+ S2_0_c1_c0_4:
6022
+ name: OSLAR_EL1
6023
+ description: OS Lock Access Register
6024
+ S2_0_c1_c1_4:
6025
+ name: OSLSR_EL1
6026
+ description: OS Lock Status Register
6027
+ S2_0_c1_c3_4:
6028
+ name: OSDLR_EL1
6029
+ description: OS Double Lock Register
6030
+ S2_0_c1_c4_4:
6031
+ name: DBGPRCR_EL1
6032
+ description: Debug Power Control Register
6033
+ S2_0_c7_c8_6:
6034
+ name: DBGCLAIMSET_EL1
6035
+ description: Debug CLAIM Tag Set register
6036
+ S2_0_c7_c9_6:
6037
+ name: DBGCLAIMCLR_EL1
6038
+ description: Debug CLAIM Tag Clear register
6039
+ S2_0_c7_c14_6:
6040
+ name: DBGAUTHSTATUS_EL1
6041
+ description: Debug Authentication Status register
6042
+ S2_3_c0_c1_0:
6043
+ name: MDCCSR_EL0
6044
+ description: Monitor DCC Status Register
6045
+ S2_3_c0_c4_0:
6046
+ name: DBGDTR_EL0
6047
+ description: Debug Data Transfer Register, half-duplex
6048
+ S2_3_c0_c5_0:
6049
+ name: DBGDTRRX_EL0
6050
+ description: Debug Data Transfer Register
6051
+ S2_4_c0_c7_0:
6052
+ name: DBGVCR32_EL2
6053
+ description: Debug Vector Catch Register
6054
+ S3_0_c0_c0_0:
6055
+ name: MIDR_EL1
6056
+ description: Main ID Register
6057
+ S3_0_c0_c0_5:
6058
+ name: MPIDR_EL1
6059
+ description: Multiprocessor Affinity Register
6060
+ S3_0_c0_c0_6:
6061
+ name: REVIDR_EL1
6062
+ description: Revision ID Register
6063
+ S3_0_c0_c1_0:
6064
+ name: ID_PFR0_EL1
6065
+ description: AArch32 Processor Feature Register 0
6066
+ S3_0_c0_c1_1:
6067
+ name: ID_PFR1_EL1
6068
+ description: AArch32 Processor Feature Register 1
6069
+ S3_0_c0_c1_2:
6070
+ name: ID_DFR0_EL1
6071
+ description: AArch32 Debug Feature Register 0
6072
+ S3_0_c0_c1_3:
6073
+ name: ID_AFR0_EL1
6074
+ description: AArch32 Auxiliary Feature Register 0
6075
+ S3_0_c0_c1_4:
6076
+ name: ID_MMFR0_EL1
6077
+ description: AArch32 Memory Model Feature Register 0
6078
+ S3_0_c0_c1_5:
6079
+ name: ID_MMFR1_EL1
6080
+ description: AArch32 Memory Model Feature Register 1
6081
+ S3_0_c0_c1_6:
6082
+ name: ID_MMFR2_EL1
6083
+ description: AArch32 Memory Model Feature Register 2
6084
+ S3_0_c0_c1_7:
6085
+ name: ID_MMFR3_EL1
6086
+ description: AArch32 Memory Model Feature Register 3
6087
+ S3_0_c0_c2_0:
6088
+ name: ID_ISAR0_EL1
6089
+ description: AArch32 Instruction Set Attribute Register 0
6090
+ S3_0_c0_c2_1:
6091
+ name: ID_ISAR1_EL1
6092
+ description: AArch32 Instruction Set Attribute Register 1
6093
+ S3_0_c0_c2_2:
6094
+ name: ID_ISAR2_EL1
6095
+ description: AArch32 Instruction Set Attribute Register 2
6096
+ S3_0_c0_c2_3:
6097
+ name: ID_ISAR3_EL1
6098
+ description: AArch32 Instruction Set Attribute Register 3
6099
+ S3_0_c0_c2_4:
6100
+ name: ID_ISAR4_EL1
6101
+ description: AArch32 Instruction Set Attribute Register 4
6102
+ S3_0_c0_c2_5:
6103
+ name: ID_ISAR5_EL1
6104
+ description: AArch32 Instruction Set Attribute Register 5
6105
+ S3_0_c0_c2_6:
6106
+ name: ID_MMFR4_EL1
6107
+ description: AArch32 Memory Model Feature Register 4
6108
+ S3_0_c0_c2_7:
6109
+ name: ID_ISAR6_EL1
6110
+ description: AArch32 Instruction Set Attribute Register 6
6111
+ S3_0_c0_c3_0:
6112
+ name: MVFR0_EL1
6113
+ description: AArch32 Media and VFP Feature Register 0
6114
+ S3_0_c0_c3_1:
6115
+ name: MVFR1_EL1
6116
+ description: AArch32 Media and VFP Feature Register 1
6117
+ S3_0_c0_c3_2:
6118
+ name: MVFR2_EL1
6119
+ description: AArch32 Media and VFP Feature Register 2
6120
+ S3_0_c0_c3_4:
6121
+ name: ID_PFR2_EL1
6122
+ description: AArch32 Processor Feature Register 2
6123
+ S3_0_c0_c3_5:
6124
+ name: ID_DFR1_EL1
6125
+ description: Debug Feature Register 1
6126
+ S3_0_c0_c3_6:
6127
+ name: ID_MMFR5_EL1
6128
+ description: AArch32 Memory Model Feature Register 5
6129
+ S3_0_c0_c4_0:
6130
+ name: ID_AA64PFR0_EL1
6131
+ description: AArch64 Processor Feature Register 0
6132
+ S3_0_c0_c4_1:
6133
+ name: ID_AA64PFR1_EL1
6134
+ description: AArch64 Processor Feature Register 1
6135
+ S3_0_c0_c4_4:
6136
+ name: ID_AA64ZFR0_EL1
6137
+ description: SVE Feature ID register 0
6138
+ S3_0_c0_c5_0:
6139
+ name: ID_AA64DFR0_EL1
6140
+ description: AArch64 Debug Feature Register 0
6141
+ S3_0_c0_c5_1:
6142
+ name: ID_AA64DFR1_EL1
6143
+ description: AArch64 Debug Feature Register 1
6144
+ S3_0_c0_c5_4:
6145
+ name: ID_AA64AFR0_EL1
6146
+ description: AArch64 Auxiliary Feature Register 0
6147
+ S3_0_c0_c5_5:
6148
+ name: ID_AA64AFR1_EL1
6149
+ description: AArch64 Auxiliary Feature Register 1
6150
+ S3_0_c0_c6_0:
6151
+ name: ID_AA64ISAR0_EL1
6152
+ description: AArch64 Instruction Set Attribute Register 0
6153
+ S3_0_c0_c6_1:
6154
+ name: ID_AA64ISAR1_EL1
6155
+ description: AArch64 Instruction Set Attribute Register 1
6156
+ S3_0_c0_c7_0:
6157
+ name: ID_AA64MMFR0_EL1
6158
+ description: AArch64 Memory Model Feature Register 0
6159
+ S3_0_c0_c7_1:
6160
+ name: ID_AA64MMFR1_EL1
6161
+ description: AArch64 Memory Model Feature Register 1
6162
+ S3_0_c0_c7_2:
6163
+ name: ID_AA64MMFR2_EL1
6164
+ description: AArch64 Memory Model Feature Register 2
6165
+ S3_0_c1_c0_0:
6166
+ name: SCTLR_EL1
6167
+ description: System Control Register (EL1)
6168
+ S3_0_c1_c0_1:
6169
+ name: ACTLR_EL1
6170
+ description: Auxiliary Control Register (EL1)
6171
+ S3_0_c1_c0_2:
6172
+ name: CPACR_EL1
6173
+ description: Architectural Feature Access Control Register
6174
+ S3_0_c1_c0_5:
6175
+ name: RGSR_EL1
6176
+ description: Random Allocation Tag Seed Register.
6177
+ S3_0_c1_c0_6:
6178
+ name: GCR_EL1
6179
+ description: Tag Control Register.
6180
+ S3_0_c1_c2_0:
6181
+ name: ZCR_EL1
6182
+ description: SVE Control Register for EL1
6183
+ S3_0_c1_c2_1:
6184
+ name: TRFCR_EL1
6185
+ description: Trace Filter Control Register (EL1)
6186
+ S3_0_c2_c0_0:
6187
+ name: TTBR0_EL1
6188
+ description: Translation Table Base Register 0 (EL1)
6189
+ S3_0_c2_c0_1:
6190
+ name: TTBR1_EL1
6191
+ description: Translation Table Base Register 1 (EL1)
6192
+ S3_0_c2_c0_2:
6193
+ name: TCR_EL1
6194
+ description: Translation Control Register (EL1)
6195
+ S3_0_c2_c1_0:
6196
+ name: APIAKeyLo_EL1
6197
+ description: 'Pointer Authentication Key A for Instruction (bits[63:0]) '
6198
+ S3_0_c2_c1_1:
6199
+ name: APIAKeyHi_EL1
6200
+ description: 'Pointer Authentication Key A for Instruction (bits[127:64]) '
6201
+ S3_0_c2_c1_2:
6202
+ name: APIBKeyLo_EL1
6203
+ description: 'Pointer Authentication Key B for Instruction (bits[63:0]) '
6204
+ S3_0_c2_c1_3:
6205
+ name: APIBKeyHi_EL1
6206
+ description: 'Pointer Authentication Key B for Instruction (bits[127:64]) '
6207
+ S3_0_c2_c2_0:
6208
+ name: APDAKeyLo_EL1
6209
+ description: 'Pointer Authentication Key A for Data (bits[63:0]) '
6210
+ S3_0_c2_c2_1:
6211
+ name: APDAKeyHi_EL1
6212
+ description: 'Pointer Authentication Key A for Data (bits[127:64]) '
6213
+ S3_0_c2_c2_2:
6214
+ name: APDBKeyLo_EL1
6215
+ description: 'Pointer Authentication Key B for Data (bits[63:0]) '
6216
+ S3_0_c2_c2_3:
6217
+ name: APDBKeyHi_EL1
6218
+ description: 'Pointer Authentication Key B for Data (bits[127:64]) '
6219
+ S3_0_c2_c3_0:
6220
+ name: APGAKeyLo_EL1
6221
+ description: 'Pointer Authentication Key A for Code (bits[63:0]) '
6222
+ S3_0_c2_c3_1:
6223
+ name: APGAKeyHi_EL1
6224
+ description: 'Pointer Authentication Key A for Code (bits[127:64]) '
6225
+ S3_0_c4_c0_0:
6226
+ name: SPSR_EL1
6227
+ description: Saved Program Status Register (EL1)
6228
+ S3_0_c4_c0_1:
6229
+ name: ELR_EL1
6230
+ description: Exception Link Register (EL1)
6231
+ S3_0_c4_c1_0:
6232
+ name: SP_EL0
6233
+ description: Stack Pointer (EL0)
6234
+ S3_0_c4_c2_0:
6235
+ name: SPSel
6236
+ description: Stack Pointer Select
6237
+ S3_0_c4_c2_2:
6238
+ name: CurrentEL
6239
+ description: Current Exception Level
6240
+ S3_0_c4_c2_3:
6241
+ name: PAN
6242
+ description: Privileged Access Never
6243
+ S3_0_c4_c2_4:
6244
+ name: UAO
6245
+ description: User Access Override
6246
+ S3_0_c4_c6_0:
6247
+ name: ICC_PMR_EL1
6248
+ description: Interrupt Controller Interrupt Priority Mask Register Interrupt
6249
+ Controller Virtual Interrupt Priority Mask Register
6250
+ S3_0_c5_c1_0:
6251
+ name: AFSR0_EL1
6252
+ description: Auxiliary Fault Status Register 0 (EL1)
6253
+ S3_0_c5_c1_1:
6254
+ name: AFSR1_EL1
6255
+ description: Auxiliary Fault Status Register 1 (EL1)
6256
+ S3_0_c5_c2_0:
6257
+ name: ESR_EL1
6258
+ description: Exception Syndrome Register (EL1)
6259
+ S3_0_c5_c3_0:
6260
+ name: ERRIDR_EL1
6261
+ description: Error Record ID Register
6262
+ S3_0_c5_c3_1:
6263
+ name: ERRSELR_EL1
6264
+ description: Error Record Select Register
6265
+ S3_0_c5_c4_0:
6266
+ name: ERXFR_EL1
6267
+ description: Selected Error Record Feature Register
6268
+ S3_0_c5_c4_1:
6269
+ name: ERXCTLR_EL1
6270
+ description: Selected Error Record Control Register
6271
+ S3_0_c5_c4_2:
6272
+ name: ERXSTATUS_EL1
6273
+ description: Selected Error Record Primary Status Register
6274
+ S3_0_c5_c4_3:
6275
+ name: ERXADDR_EL1
6276
+ description: Selected Error Record Address Register
6277
+ S3_0_c5_c4_4:
6278
+ name: ERXPFGF_EL1
6279
+ description: Selected Pseudo-fault Generation Feature register
6280
+ S3_0_c5_c4_5:
6281
+ name: ERXPFGCTL_EL1
6282
+ description: Selected Pseudo-fault Generation Control register
6283
+ S3_0_c5_c4_6:
6284
+ name: ERXPFGCDN_EL1
6285
+ description: Selected Pseudo-fault Generation Countdown register
6286
+ S3_0_c5_c5_0:
6287
+ name: ERXMISC0_EL1
6288
+ description: Selected Error Record Miscellaneous Register 0
6289
+ S3_0_c5_c5_1:
6290
+ name: ERXMISC1_EL1
6291
+ description: Selected Error Record Miscellaneous Register 1
6292
+ S3_0_c5_c5_2:
6293
+ name: ERXMISC2_EL1
6294
+ description: Selected Error Record Miscellaneous Register 2
6295
+ S3_0_c5_c5_3:
6296
+ name: ERXMISC3_EL1
6297
+ description: Selected Error Record Miscellaneous Register 3
6298
+ S3_0_c5_c6_0:
6299
+ name: TFSR_EL1
6300
+ description: Tag Fault Status Register (EL1)
6301
+ S3_0_c5_c6_1:
6302
+ name: TFSRE0_EL1
6303
+ description: Tag Fault Status Register (EL0).
6304
+ S3_0_c6_c0_0:
6305
+ name: FAR_EL1
6306
+ description: Fault Address Register (EL1)
6307
+ S3_0_c7_c4_0:
6308
+ name: PAR_EL1
6309
+ description: Physical Address Register
6310
+ S3_0_c9_c9_0:
6311
+ name: PMSCR_EL1
6312
+ description: Statistical Profiling Control Register (EL1)
6313
+ S3_0_c9_c9_2:
6314
+ name: PMSICR_EL1
6315
+ description: Sampling Interval Counter Register
6316
+ S3_0_c9_c9_3:
6317
+ name: PMSIRR_EL1
6318
+ description: Sampling Interval Reload Register
6319
+ S3_0_c9_c9_4:
6320
+ name: PMSFCR_EL1
6321
+ description: Sampling Filter Control Register
6322
+ S3_0_c9_c9_5:
6323
+ name: PMSEVFR_EL1
6324
+ description: Sampling Event Filter Register
6325
+ S3_0_c9_c9_6:
6326
+ name: PMSLATFR_EL1
6327
+ description: Sampling Latency Filter Register
6328
+ S3_0_c9_c9_7:
6329
+ name: PMSIDR_EL1
6330
+ description: Sampling Profiling ID Register
6331
+ S3_0_c9_c10_0:
6332
+ name: PMBLIMITR_EL1
6333
+ description: Profiling Buffer Limit Address Register
6334
+ S3_0_c9_c10_1:
6335
+ name: PMBPTR_EL1
6336
+ description: Profiling Buffer Write Pointer Register
6337
+ S3_0_c9_c10_3:
6338
+ name: PMBSR_EL1
6339
+ description: Profiling Buffer Status/syndrome Register
6340
+ S3_0_c9_c10_7:
6341
+ name: PMBIDR_EL1
6342
+ description: Profiling Buffer ID Register
6343
+ S3_0_c9_c14_1:
6344
+ name: PMINTENSET_EL1
6345
+ description: Performance Monitors Interrupt Enable Set register
6346
+ S3_0_c9_c14_2:
6347
+ name: PMINTENCLR_EL1
6348
+ description: Performance Monitors Interrupt Enable Clear register
6349
+ S3_0_c9_c14_6:
6350
+ name: PMMIR_EL1
6351
+ description: Performance Monitors Machine Identification Register
6352
+ S3_0_c10_c2_0:
6353
+ name: MAIR_EL1
6354
+ description: Memory Attribute Indirection Register (EL1)
6355
+ S3_0_c10_c3_0:
6356
+ name: AMAIR_EL1
6357
+ description: Auxiliary Memory Attribute Indirection Register (EL1)
6358
+ S3_0_c10_c4_0:
6359
+ name: LORSA_EL1
6360
+ description: LORegion Start Address (EL1)
6361
+ S3_0_c10_c4_1:
6362
+ name: LOREA_EL1
6363
+ description: LORegion End Address (EL1)
6364
+ S3_0_c10_c4_2:
6365
+ name: LORN_EL1
6366
+ description: LORegion Number (EL1)
6367
+ S3_0_c10_c4_3:
6368
+ name: LORC_EL1
6369
+ description: LORegion Control (EL1)
6370
+ S3_0_c10_c4_4:
6371
+ name: MPAMIDR_EL1
6372
+ description: MPAM ID Register (EL1)
6373
+ S3_0_c10_c4_7:
6374
+ name: LORID_EL1
6375
+ description: LORegionID (EL1)
6376
+ S3_0_c10_c5_0:
6377
+ name: MPAM1_EL1
6378
+ description: MPAM1 Register (EL1)
6379
+ S3_0_c10_c5_1:
6380
+ name: MPAM0_EL1
6381
+ description: MPAM0 Register (EL1)
6382
+ S3_0_c12_c0_0:
6383
+ name: VBAR_EL1
6384
+ description: Vector Base Address Register (EL1)
6385
+ S3_0_c12_c0_1:
6386
+ name: RVBAR_EL1
6387
+ description: Reset Vector Base Address Register (if EL2 and EL3 not implemented)
6388
+ S3_0_c12_c0_2:
6389
+ name: RMR_EL1
6390
+ description: Reset Management Register (EL1)
6391
+ S3_0_c12_c1_0:
6392
+ name: ISR_EL1
6393
+ description: Interrupt Status Register
6394
+ S3_0_c12_c1_1:
6395
+ name: DISR_EL1
6396
+ description: Deferred Interrupt Status Register
6397
+ S3_0_c12_c8_0:
6398
+ name: ICC_IAR0_EL1
6399
+ description: Interrupt Controller Interrupt Acknowledge Register 0 Interrupt
6400
+ Controller Virtual Interrupt Acknowledge Register 0
6401
+ S3_0_c12_c8_1:
6402
+ name: ICC_EOIR0_EL1
6403
+ description: Interrupt Controller End Of Interrupt Register 0 Interrupt Controller
6404
+ Virtual End Of Interrupt Register 0
6405
+ S3_0_c12_c8_2:
6406
+ name: ICC_HPPIR0_EL1
6407
+ description: Interrupt Controller Highest Priority Pending Interrupt Register
6408
+ 0 Interrupt Controller Virtual Highest Priority Pending Interrupt Register
6409
+ 0
6410
+ S3_0_c12_c8_3:
6411
+ name: ICC_BPR0_EL1
6412
+ description: Interrupt Controller Binary Point Register 0 Interrupt Controller
6413
+ Virtual Binary Point Register 0
6414
+ S3_0_c12_c8_4:
6415
+ name: ICC_AP0R0_EL1
6416
+ description: Interrupt Controller Active Priorities Group 0 Register 0 Interrupt
6417
+ Controller Virtual Active Priorities Group 0 Register 0
6418
+ S3_0_c12_c8_5:
6419
+ name: ICC_AP0R1_EL1
6420
+ description: Interrupt Controller Active Priorities Group 0 Register 1 Interrupt
6421
+ Controller Virtual Active Priorities Group 0 Register 1
6422
+ S3_0_c12_c8_6:
6423
+ name: ICC_AP0R2_EL1
6424
+ description: Interrupt Controller Active Priorities Group 0 Register 2 Interrupt
6425
+ Controller Virtual Active Priorities Group 0 Register 2
6426
+ S3_0_c12_c8_7:
6427
+ name: ICC_AP0R3_EL1
6428
+ description: Interrupt Controller Active Priorities Group 0 Register 3 Interrupt
6429
+ Controller Virtual Active Priorities Group 0 Register 3
6430
+ S3_0_c12_c9_0:
6431
+ name: ICC_AP1R0_EL1
6432
+ description: Interrupt Controller Active Priorities Group 1 Register 0 Interrupt
6433
+ Controller Virtual Active Priorities Group 1 Register 0
6434
+ S3_0_c12_c9_1:
6435
+ name: ICC_AP1R1_EL1
6436
+ description: Interrupt Controller Active Priorities Group 1 Register 1 Interrupt
6437
+ Controller Virtual Active Priorities Group 1 Register 1
6438
+ S3_0_c12_c9_2:
6439
+ name: ICC_AP1R2_EL1
6440
+ description: Interrupt Controller Active Priorities Group 1 Register 2 Interrupt
6441
+ Controller Virtual Active Priorities Group 1 Register 2
6442
+ S3_0_c12_c9_3:
6443
+ name: ICC_AP1R3_EL1
6444
+ description: Interrupt Controller Active Priorities Group 1 Register 3 Interrupt
6445
+ Controller Virtual Active Priorities Group 1 Register 3
6446
+ S3_0_c12_c11_1:
6447
+ name: ICC_DIR_EL1
6448
+ description: Interrupt Controller Deactivate Interrupt Register Interrupt Controller
6449
+ Deactivate Virtual Interrupt Register
6450
+ S3_0_c12_c11_3:
6451
+ name: ICC_RPR_EL1
6452
+ description: Interrupt Controller Running Priority Register Interrupt Controller
6453
+ Virtual Running Priority Register
6454
+ S3_0_c12_c11_5:
6455
+ name: ICC_SGI1R_EL1
6456
+ description: Interrupt Controller Software Generated Interrupt Group 1 Register
6457
+ S3_0_c12_c11_6:
6458
+ name: ICC_ASGI1R_EL1
6459
+ description: Interrupt Controller Alias Software Generated Interrupt Group 1
6460
+ Register
6461
+ S3_0_c12_c11_7:
6462
+ name: ICC_SGI0R_EL1
6463
+ description: Interrupt Controller Software Generated Interrupt Group 0 Register
6464
+ S3_0_c12_c12_0:
6465
+ name: ICC_IAR1_EL1
6466
+ description: Interrupt Controller Interrupt Acknowledge Register 1 Interrupt
6467
+ Controller Virtual Interrupt Acknowledge Register 1
6468
+ S3_0_c12_c12_1:
6469
+ name: ICC_EOIR1_EL1
6470
+ description: Interrupt Controller End Of Interrupt Register 1 Interrupt Controller
6471
+ Virtual End Of Interrupt Register 1
6472
+ S3_0_c12_c12_2:
6473
+ name: ICC_HPPIR1_EL1
6474
+ description: Interrupt Controller Highest Priority Pending Interrupt Register
6475
+ 1 Interrupt Controller Virtual Highest Priority Pending Interrupt Register
6476
+ 1
6477
+ S3_0_c12_c12_3:
6478
+ name: ICC_BPR1_EL1
6479
+ description: Interrupt Controller Binary Point Register 1 Interrupt Controller
6480
+ Virtual Binary Point Register 1
6481
+ S3_0_c12_c12_4:
6482
+ name: ICC_CTLR_EL1
6483
+ description: Interrupt Controller Control Register (EL1) Interrupt Controller
6484
+ Virtual Control Register
6485
+ S3_0_c12_c12_5:
6486
+ name: ICC_SRE_EL1
6487
+ description: Interrupt Controller System Register Enable register (EL1)
6488
+ S3_0_c12_c12_6:
6489
+ name: ICC_IGRPEN0_EL1
6490
+ description: Interrupt Controller Interrupt Group 0 Enable register Interrupt
6491
+ Controller Virtual Interrupt Group 0 Enable register
6492
+ S3_0_c12_c12_7:
6493
+ name: ICC_IGRPEN1_EL1
6494
+ description: Interrupt Controller Interrupt Group 1 Enable register Interrupt
6495
+ Controller Virtual Interrupt Group 1 Enable register
6496
+ S3_0_c13_c0_1:
6497
+ name: CONTEXTIDR_EL1
6498
+ description: Context ID Register (EL1)
6499
+ S3_0_c13_c0_4:
6500
+ name: TPIDR_EL1
6501
+ description: EL1 Software Thread ID Register
6502
+ S3_0_c13_c0_7:
6503
+ name: SCXTNUM_EL1
6504
+ description: EL1 Read/Write Software Context Number
6505
+ S3_0_c14_c1_0:
6506
+ name: CNTKCTL_EL1
6507
+ description: Counter-timer Kernel Control register
6508
+ S3_1_c0_c0_0:
6509
+ name: CCSIDR_EL1
6510
+ description: Current Cache Size ID Register
6511
+ S3_1_c0_c0_1:
6512
+ name: CLIDR_EL1
6513
+ description: Cache Level ID Register
6514
+ S3_1_c0_c0_2:
6515
+ name: CCSIDR2_EL1
6516
+ description: Current Cache Size ID Register 2
6517
+ S3_1_c0_c0_4:
6518
+ name: GMID_EL1
6519
+ description: " Multiple tag transfer ID register"
6520
+ S3_1_c0_c0_7:
6521
+ name: AIDR_EL1
6522
+ description: Auxiliary ID Register
6523
+ S3_2_c0_c0_0:
6524
+ name: CSSELR_EL1
6525
+ description: Cache Size Selection Register
6526
+ S3_3_c0_c0_1:
6527
+ name: CTR_EL0
6528
+ description: Cache Type Register
6529
+ S3_3_c0_c0_7:
6530
+ name: DCZID_EL0
6531
+ description: Data Cache Zero ID register
6532
+ S3_3_c2_c4_0:
6533
+ name: RNDR
6534
+ description: Random Number
6535
+ S3_3_c2_c4_1:
6536
+ name: RNDRRS
6537
+ description: Reseeded Random Number
6538
+ S3_3_c4_c2_0:
6539
+ name: NZCV
6540
+ description: Condition Flags
6541
+ S3_3_c4_c2_1:
6542
+ name: DAIF
6543
+ description: Interrupt Mask Bits
6544
+ S3_3_c4_c2_5:
6545
+ name: DIT
6546
+ description: Data Independent Timing
6547
+ S3_3_c4_c2_6:
6548
+ name: SSBS
6549
+ description: Speculative Store Bypass Safe
6550
+ S3_3_c4_c2_7:
6551
+ name: TCO
6552
+ description: Tag Check Override
6553
+ S3_3_c4_c4_0:
6554
+ name: FPCR
6555
+ description: Floating-point Control Register
6556
+ S3_3_c4_c4_1:
6557
+ name: FPSR
6558
+ description: Floating-point Status Register
6559
+ S3_3_c4_c5_0:
6560
+ name: DSPSR_EL0
6561
+ description: Debug Saved Program Status Register
6562
+ S3_3_c4_c5_1:
6563
+ name: DLR_EL0
6564
+ description: Debug Link Register
6565
+ S3_3_c9_c12_0:
6566
+ name: PMCR_EL0
6567
+ description: Performance Monitors Control Register
6568
+ S3_3_c9_c12_1:
6569
+ name: PMCNTENSET_EL0
6570
+ description: Performance Monitors Count Enable Set register
6571
+ S3_3_c9_c12_2:
6572
+ name: PMCNTENCLR_EL0
6573
+ description: Performance Monitors Count Enable Clear register
6574
+ S3_3_c9_c12_3:
6575
+ name: PMOVSCLR_EL0
6576
+ description: Performance Monitors Overflow Flag Status Clear Register
6577
+ S3_3_c9_c12_4:
6578
+ name: PMSWINC_EL0
6579
+ description: Performance Monitors Software Increment register
6580
+ S3_3_c9_c12_5:
6581
+ name: PMSELR_EL0
6582
+ description: Performance Monitors Event Counter Selection Register
6583
+ S3_3_c9_c12_6:
6584
+ name: PMCEID0_EL0
6585
+ description: Performance Monitors Common Event Identification register 0
6586
+ S3_3_c9_c12_7:
6587
+ name: PMCEID1_EL0
6588
+ description: Performance Monitors Common Event Identification register 1
6589
+ S3_3_c9_c13_0:
6590
+ name: PMCCNTR_EL0
6591
+ description: Performance Monitors Cycle Count Register
6592
+ S3_3_c9_c13_1:
6593
+ name: PMXEVTYPER_EL0
6594
+ description: Performance Monitors Selected Event Type Register
6595
+ S3_3_c9_c13_2:
6596
+ name: PMXEVCNTR_EL0
6597
+ description: Performance Monitors Selected Event Count Register
6598
+ S3_3_c9_c14_0:
6599
+ name: PMUSERENR_EL0
6600
+ description: Performance Monitors User Enable Register
6601
+ S3_3_c9_c14_3:
6602
+ name: PMOVSSET_EL0
6603
+ description: Performance Monitors Overflow Flag Status Set register
6604
+ S3_3_c13_c0_2:
6605
+ name: TPIDR_EL0
6606
+ description: EL0 Read/Write Software Thread ID Register
6607
+ S3_3_c13_c0_3:
6608
+ name: TPIDRRO_EL0
6609
+ description: EL0 Read-Only Software Thread ID Register
6610
+ S3_3_c13_c0_7:
6611
+ name: SCXTNUM_EL0
6612
+ description: EL0 Read/Write Software Context Number
6613
+ S3_3_c13_c2_0:
6614
+ name: AMCR_EL0
6615
+ description: Activity Monitors Control Register
6616
+ S3_3_c13_c2_1:
6617
+ name: AMCFGR_EL0
6618
+ description: Activity Monitors Configuration Register
6619
+ S3_3_c13_c2_2:
6620
+ name: AMCGCR_EL0
6621
+ description: Activity Monitors Counter Group Configuration Register
6622
+ S3_3_c13_c2_3:
6623
+ name: AMUSERENR_EL0
6624
+ description: Activity Monitors User Enable Register
6625
+ S3_3_c13_c2_4:
6626
+ name: AMCNTENCLR0_EL0
6627
+ description: Activity Monitors Count Enable Clear Register 0
6628
+ S3_3_c13_c2_5:
6629
+ name: AMCNTENSET0_EL0
6630
+ description: Activity Monitors Count Enable Set Register 0
6631
+ S3_3_c13_c2_6:
6632
+ name: AMCG1IDR_EL0
6633
+ description: Activity Monitors Counter Group 1 Identification Register
6634
+ S3_3_c13_c3_0:
6635
+ name: AMCNTENCLR1_EL0
6636
+ description: Activity Monitors Count Enable Clear Register 1
6637
+ S3_3_c13_c3_1:
6638
+ name: AMCNTENSET1_EL0
6639
+ description: Activity Monitors Count Enable Set Register 1
6640
+ S3_3_c13_c4_0:
6641
+ name: AMEVCNTR00_EL0
6642
+ description: Activity Monitors Event Counter Register 0 0
6643
+ S3_3_c13_c4_1:
6644
+ name: AMEVCNTR01_EL0
6645
+ description: Activity Monitors Event Counter Register 0 1
6646
+ S3_3_c13_c4_2:
6647
+ name: AMEVCNTR02_EL0
6648
+ description: Activity Monitors Event Counter Register 0 2
6649
+ S3_3_c13_c4_3:
6650
+ name: AMEVCNTR03_EL0
6651
+ description: Activity Monitors Event Counter Register 0 3
6652
+ S3_3_c13_c4_4:
6653
+ name: AMEVCNTR04_EL0
6654
+ description: Activity Monitors Event Counter Register 0 4
6655
+ S3_3_c13_c4_5:
6656
+ name: AMEVCNTR05_EL0
6657
+ description: Activity Monitors Event Counter Register 0 5
6658
+ S3_3_c13_c4_6:
6659
+ name: AMEVCNTR06_EL0
6660
+ description: Activity Monitors Event Counter Register 0 6
6661
+ S3_3_c13_c4_7:
6662
+ name: AMEVCNTR07_EL0
6663
+ description: Activity Monitors Event Counter Register 0 7
6664
+ S3_3_c13_c5_0:
6665
+ name: AMEVCNTR08_EL0
6666
+ description: Activity Monitors Event Counter Register 0 8
6667
+ S3_3_c13_c5_1:
6668
+ name: AMEVCNTR09_EL0
6669
+ description: Activity Monitors Event Counter Register 0 9
6670
+ S3_3_c13_c5_2:
6671
+ name: AMEVCNTR010_EL0
6672
+ description: Activity Monitors Event Counter Register 0 10
6673
+ S3_3_c13_c5_3:
6674
+ name: AMEVCNTR011_EL0
6675
+ description: Activity Monitors Event Counter Register 0 11
6676
+ S3_3_c13_c5_4:
6677
+ name: AMEVCNTR012_EL0
6678
+ description: Activity Monitors Event Counter Register 0 12
6679
+ S3_3_c13_c5_5:
6680
+ name: AMEVCNTR013_EL0
6681
+ description: Activity Monitors Event Counter Register 0 13
6682
+ S3_3_c13_c5_6:
6683
+ name: AMEVCNTR014_EL0
6684
+ description: Activity Monitors Event Counter Register 0 14
6685
+ S3_3_c13_c5_7:
6686
+ name: AMEVCNTR015_EL0
6687
+ description: Activity Monitors Event Counter Register 0 15
6688
+ S3_3_c13_c6_0:
6689
+ name: AMEVTYPER00_EL0
6690
+ description: Activity Monitors Event Type Register 0 0
6691
+ S3_3_c13_c6_1:
6692
+ name: AMEVTYPER01_EL0
6693
+ description: Activity Monitors Event Type Register 0 1
6694
+ S3_3_c13_c6_2:
6695
+ name: AMEVTYPER02_EL0
6696
+ description: Activity Monitors Event Type Register 0 2
6697
+ S3_3_c13_c6_3:
6698
+ name: AMEVTYPER03_EL0
6699
+ description: Activity Monitors Event Type Register 0 3
6700
+ S3_3_c13_c6_4:
6701
+ name: AMEVTYPER04_EL0
6702
+ description: Activity Monitors Event Type Register 0 4
6703
+ S3_3_c13_c6_5:
6704
+ name: AMEVTYPER05_EL0
6705
+ description: Activity Monitors Event Type Register 0 5
6706
+ S3_3_c13_c6_6:
6707
+ name: AMEVTYPER06_EL0
6708
+ description: Activity Monitors Event Type Register 0 6
6709
+ S3_3_c13_c6_7:
6710
+ name: AMEVTYPER07_EL0
6711
+ description: Activity Monitors Event Type Register 0 7
6712
+ S3_3_c13_c7_0:
6713
+ name: AMEVTYPER08_EL0
6714
+ description: Activity Monitors Event Type Register 0 8
6715
+ S3_3_c13_c7_1:
6716
+ name: AMEVTYPER09_EL0
6717
+ description: Activity Monitors Event Type Register 0 9
6718
+ S3_3_c13_c7_2:
6719
+ name: AMEVTYPER010_EL0
6720
+ description: Activity Monitors Event Type Register 0 10
6721
+ S3_3_c13_c7_3:
6722
+ name: AMEVTYPER011_EL0
6723
+ description: Activity Monitors Event Type Register 0 11
6724
+ S3_3_c13_c7_4:
6725
+ name: AMEVTYPER012_EL0
6726
+ description: Activity Monitors Event Type Register 0 12
6727
+ S3_3_c13_c7_5:
6728
+ name: AMEVTYPER013_EL0
6729
+ description: Activity Monitors Event Type Register 0 13
6730
+ S3_3_c13_c7_6:
6731
+ name: AMEVTYPER014_EL0
6732
+ description: Activity Monitors Event Type Register 0 14
6733
+ S3_3_c13_c7_7:
6734
+ name: AMEVTYPER015_EL0
6735
+ description: Activity Monitors Event Type Register 0 15
6736
+ S3_3_c13_c12_0:
6737
+ name: AMEVCNTR10_EL0
6738
+ description: Activity Monitors Event Counter Register 1 0
6739
+ S3_3_c13_c12_1:
6740
+ name: AMEVCNTR11_EL0
6741
+ description: Activity Monitors Event Counter Register 1 1
6742
+ S3_3_c13_c12_2:
6743
+ name: AMEVCNTR12_EL0
6744
+ description: Activity Monitors Event Counter Register 1 2
6745
+ S3_3_c13_c12_3:
6746
+ name: AMEVCNTR13_EL0
6747
+ description: Activity Monitors Event Counter Register 1 3
6748
+ S3_3_c13_c12_4:
6749
+ name: AMEVCNTR14_EL0
6750
+ description: Activity Monitors Event Counter Register 1 4
6751
+ S3_3_c13_c12_5:
6752
+ name: AMEVCNTR15_EL0
6753
+ description: Activity Monitors Event Counter Register 1 5
6754
+ S3_3_c13_c12_6:
6755
+ name: AMEVCNTR16_EL0
6756
+ description: Activity Monitors Event Counter Register 1 6
6757
+ S3_3_c13_c12_7:
6758
+ name: AMEVCNTR17_EL0
6759
+ description: Activity Monitors Event Counter Register 1 7
6760
+ S3_3_c13_c13_0:
6761
+ name: AMEVCNTR18_EL0
6762
+ description: Activity Monitors Event Counter Register 1 8
6763
+ S3_3_c13_c13_1:
6764
+ name: AMEVCNTR19_EL0
6765
+ description: Activity Monitors Event Counter Register 1 9
6766
+ S3_3_c13_c13_2:
6767
+ name: AMEVCNTR110_EL0
6768
+ description: Activity Monitors Event Counter Register 1 10
6769
+ S3_3_c13_c13_3:
6770
+ name: AMEVCNTR111_EL0
6771
+ description: Activity Monitors Event Counter Register 1 11
6772
+ S3_3_c13_c13_4:
6773
+ name: AMEVCNTR112_EL0
6774
+ description: Activity Monitors Event Counter Register 1 12
6775
+ S3_3_c13_c13_5:
6776
+ name: AMEVCNTR113_EL0
6777
+ description: Activity Monitors Event Counter Register 1 13
6778
+ S3_3_c13_c13_6:
6779
+ name: AMEVCNTR114_EL0
6780
+ description: Activity Monitors Event Counter Register 1 14
6781
+ S3_3_c13_c13_7:
6782
+ name: AMEVCNTR115_EL0
6783
+ description: Activity Monitors Event Counter Register 1 15
6784
+ S3_3_c13_c14_0:
6785
+ name: AMEVTYPER10_EL0
6786
+ description: Activity Monitors Event Type Register 1 0
6787
+ S3_3_c13_c14_1:
6788
+ name: AMEVTYPER11_EL0
6789
+ description: Activity Monitors Event Type Register 1 1
6790
+ S3_3_c13_c14_2:
6791
+ name: AMEVTYPER12_EL0
6792
+ description: Activity Monitors Event Type Register 1 2
6793
+ S3_3_c13_c14_3:
6794
+ name: AMEVTYPER13_EL0
6795
+ description: Activity Monitors Event Type Register 1 3
6796
+ S3_3_c13_c14_4:
6797
+ name: AMEVTYPER14_EL0
6798
+ description: Activity Monitors Event Type Register 1 4
6799
+ S3_3_c13_c14_5:
6800
+ name: AMEVTYPER15_EL0
6801
+ description: Activity Monitors Event Type Register 1 5
6802
+ S3_3_c13_c14_6:
6803
+ name: AMEVTYPER16_EL0
6804
+ description: Activity Monitors Event Type Register 1 6
6805
+ S3_3_c13_c14_7:
6806
+ name: AMEVTYPER17_EL0
6807
+ description: Activity Monitors Event Type Register 1 7
6808
+ S3_3_c13_c15_0:
6809
+ name: AMEVTYPER18_EL0
6810
+ description: Activity Monitors Event Type Register 1 8
6811
+ S3_3_c13_c15_1:
6812
+ name: AMEVTYPER19_EL0
6813
+ description: Activity Monitors Event Type Register 1 9
6814
+ S3_3_c13_c15_2:
6815
+ name: AMEVTYPER110_EL0
6816
+ description: Activity Monitors Event Type Register 1 10
6817
+ S3_3_c13_c15_3:
6818
+ name: AMEVTYPER111_EL0
6819
+ description: Activity Monitors Event Type Register 1 11
6820
+ S3_3_c13_c15_4:
6821
+ name: AMEVTYPER112_EL0
6822
+ description: Activity Monitors Event Type Register 1 12
6823
+ S3_3_c13_c15_5:
6824
+ name: AMEVTYPER113_EL0
6825
+ description: Activity Monitors Event Type Register 1 13
6826
+ S3_3_c13_c15_6:
6827
+ name: AMEVTYPER114_EL0
6828
+ description: Activity Monitors Event Type Register 1 14
6829
+ S3_3_c13_c15_7:
6830
+ name: AMEVTYPER115_EL0
6831
+ description: Activity Monitors Event Type Register 1 15
6832
+ S3_3_c14_c0_0:
6833
+ name: CNTFRQ_EL0
6834
+ description: Counter-timer Frequency register
6835
+ S3_3_c14_c0_1:
6836
+ name: CNTPCT_EL0
6837
+ description: Counter-timer Physical Count register
6838
+ S3_3_c14_c0_2:
6839
+ name: CNTVCT_EL0
6840
+ description: Counter-timer Virtual Count register
6841
+ S3_3_c14_c0_5:
6842
+ name: CNTPCTSS_EL0
6843
+ description: Counter-timer Self-Synchronized Physical Count register
6844
+ S3_3_c14_c0_6:
6845
+ name: CNTVCTSS_EL0
6846
+ description: Counter-timer Self-Synchronized Virtual Count register
6847
+ S3_3_c14_c2_0:
6848
+ name: CNTP_TVAL_EL0
6849
+ description: Counter-timer Physical Timer TimerValue register
6850
+ S3_3_c14_c2_1:
6851
+ name: CNTP_CTL_EL0
6852
+ description: Counter-timer Physical Timer Control register
6853
+ S3_3_c14_c2_2:
6854
+ name: CNTP_CVAL_EL0
6855
+ description: Counter-timer Physical Timer CompareValue register
6856
+ S3_3_c14_c3_0:
6857
+ name: CNTV_TVAL_EL0
6858
+ description: Counter-timer Virtual Timer TimerValue register
6859
+ S3_3_c14_c3_1:
6860
+ name: CNTV_CTL_EL0
6861
+ description: Counter-timer Virtual Timer Control register
6862
+ S3_3_c14_c3_2:
6863
+ name: CNTV_CVAL_EL0
6864
+ description: Counter-timer Virtual Timer CompareValue register
6865
+ S3_3_c14_c8_0:
6866
+ name: PMEVCNTR0_EL0
6867
+ description: Performance Monitors Event Count Register 0
6868
+ S3_3_c14_c8_1:
6869
+ name: PMEVCNTR1_EL0
6870
+ description: Performance Monitors Event Count Register 1
6871
+ S3_3_c14_c8_2:
6872
+ name: PMEVCNTR2_EL0
6873
+ description: Performance Monitors Event Count Register 2
6874
+ S3_3_c14_c8_3:
6875
+ name: PMEVCNTR3_EL0
6876
+ description: Performance Monitors Event Count Register 3
6877
+ S3_3_c14_c8_4:
6878
+ name: PMEVCNTR4_EL0
6879
+ description: Performance Monitors Event Count Register 4
6880
+ S3_3_c14_c8_5:
6881
+ name: PMEVCNTR5_EL0
6882
+ description: Performance Monitors Event Count Register 5
6883
+ S3_3_c14_c8_6:
6884
+ name: PMEVCNTR6_EL0
6885
+ description: Performance Monitors Event Count Register 6
6886
+ S3_3_c14_c8_7:
6887
+ name: PMEVCNTR7_EL0
6888
+ description: Performance Monitors Event Count Register 7
6889
+ S3_3_c14_c9_0:
6890
+ name: PMEVCNTR8_EL0
6891
+ description: Performance Monitors Event Count Register 8
6892
+ S3_3_c14_c9_1:
6893
+ name: PMEVCNTR9_EL0
6894
+ description: Performance Monitors Event Count Register 9
6895
+ S3_3_c14_c9_2:
6896
+ name: PMEVCNTR10_EL0
6897
+ description: Performance Monitors Event Count Register 10
6898
+ S3_3_c14_c9_3:
6899
+ name: PMEVCNTR11_EL0
6900
+ description: Performance Monitors Event Count Register 11
6901
+ S3_3_c14_c9_4:
6902
+ name: PMEVCNTR12_EL0
6903
+ description: Performance Monitors Event Count Register 12
6904
+ S3_3_c14_c9_5:
6905
+ name: PMEVCNTR13_EL0
6906
+ description: Performance Monitors Event Count Register 13
6907
+ S3_3_c14_c9_6:
6908
+ name: PMEVCNTR14_EL0
6909
+ description: Performance Monitors Event Count Register 14
6910
+ S3_3_c14_c9_7:
6911
+ name: PMEVCNTR15_EL0
6912
+ description: Performance Monitors Event Count Register 15
6913
+ S3_3_c14_c10_0:
6914
+ name: PMEVCNTR16_EL0
6915
+ description: Performance Monitors Event Count Register 16
6916
+ S3_3_c14_c10_1:
6917
+ name: PMEVCNTR17_EL0
6918
+ description: Performance Monitors Event Count Register 17
6919
+ S3_3_c14_c10_2:
6920
+ name: PMEVCNTR18_EL0
6921
+ description: Performance Monitors Event Count Register 18
6922
+ S3_3_c14_c10_3:
6923
+ name: PMEVCNTR19_EL0
6924
+ description: Performance Monitors Event Count Register 19
6925
+ S3_3_c14_c10_4:
6926
+ name: PMEVCNTR20_EL0
6927
+ description: Performance Monitors Event Count Register 20
6928
+ S3_3_c14_c10_5:
6929
+ name: PMEVCNTR21_EL0
6930
+ description: Performance Monitors Event Count Register 21
6931
+ S3_3_c14_c10_6:
6932
+ name: PMEVCNTR22_EL0
6933
+ description: Performance Monitors Event Count Register 22
6934
+ S3_3_c14_c10_7:
6935
+ name: PMEVCNTR23_EL0
6936
+ description: Performance Monitors Event Count Register 23
6937
+ S3_3_c14_c11_0:
6938
+ name: PMEVCNTR24_EL0
6939
+ description: Performance Monitors Event Count Register 24
6940
+ S3_3_c14_c11_1:
6941
+ name: PMEVCNTR25_EL0
6942
+ description: Performance Monitors Event Count Register 25
6943
+ S3_3_c14_c11_2:
6944
+ name: PMEVCNTR26_EL0
6945
+ description: Performance Monitors Event Count Register 26
6946
+ S3_3_c14_c11_3:
6947
+ name: PMEVCNTR27_EL0
6948
+ description: Performance Monitors Event Count Register 27
6949
+ S3_3_c14_c11_4:
6950
+ name: PMEVCNTR28_EL0
6951
+ description: Performance Monitors Event Count Register 28
6952
+ S3_3_c14_c11_5:
6953
+ name: PMEVCNTR29_EL0
6954
+ description: Performance Monitors Event Count Register 29
6955
+ S3_3_c14_c11_6:
6956
+ name: PMEVCNTR30_EL0
6957
+ description: Performance Monitors Event Count Register 30
6958
+ S3_3_c14_c11_7:
6959
+ name: PMEVCNTR31_EL0
6960
+ description: Performance Monitors Event Count Register 31
6961
+ S3_3_c14_c12_0:
6962
+ name: PMEVTYPER0_EL0
6963
+ description: Performance Monitors Event Type Register 0
6964
+ S3_3_c14_c12_1:
6965
+ name: PMEVTYPER1_EL0
6966
+ description: Performance Monitors Event Type Register 1
6967
+ S3_3_c14_c12_2:
6968
+ name: PMEVTYPER2_EL0
6969
+ description: Performance Monitors Event Type Register 2
6970
+ S3_3_c14_c12_3:
6971
+ name: PMEVTYPER3_EL0
6972
+ description: Performance Monitors Event Type Register 3
6973
+ S3_3_c14_c12_4:
6974
+ name: PMEVTYPER4_EL0
6975
+ description: Performance Monitors Event Type Register 4
6976
+ S3_3_c14_c12_5:
6977
+ name: PMEVTYPER5_EL0
6978
+ description: Performance Monitors Event Type Register 5
6979
+ S3_3_c14_c12_6:
6980
+ name: PMEVTYPER6_EL0
6981
+ description: Performance Monitors Event Type Register 6
6982
+ S3_3_c14_c12_7:
6983
+ name: PMEVTYPER7_EL0
6984
+ description: Performance Monitors Event Type Register 7
6985
+ S3_3_c14_c13_0:
6986
+ name: PMEVTYPER8_EL0
6987
+ description: Performance Monitors Event Type Register 8
6988
+ S3_3_c14_c13_1:
6989
+ name: PMEVTYPER9_EL0
6990
+ description: Performance Monitors Event Type Register 9
6991
+ S3_3_c14_c13_2:
6992
+ name: PMEVTYPER10_EL0
6993
+ description: Performance Monitors Event Type Register 10
6994
+ S3_3_c14_c13_3:
6995
+ name: PMEVTYPER11_EL0
6996
+ description: Performance Monitors Event Type Register 11
6997
+ S3_3_c14_c13_4:
6998
+ name: PMEVTYPER12_EL0
6999
+ description: Performance Monitors Event Type Register 12
7000
+ S3_3_c14_c13_5:
7001
+ name: PMEVTYPER13_EL0
7002
+ description: Performance Monitors Event Type Register 13
7003
+ S3_3_c14_c13_6:
7004
+ name: PMEVTYPER14_EL0
7005
+ description: Performance Monitors Event Type Register 14
7006
+ S3_3_c14_c13_7:
7007
+ name: PMEVTYPER15_EL0
7008
+ description: Performance Monitors Event Type Register 15
7009
+ S3_3_c14_c14_0:
7010
+ name: PMEVTYPER16_EL0
7011
+ description: Performance Monitors Event Type Register 16
7012
+ S3_3_c14_c14_1:
7013
+ name: PMEVTYPER17_EL0
7014
+ description: Performance Monitors Event Type Register 17
7015
+ S3_3_c14_c14_2:
7016
+ name: PMEVTYPER18_EL0
7017
+ description: Performance Monitors Event Type Register 18
7018
+ S3_3_c14_c14_3:
7019
+ name: PMEVTYPER19_EL0
7020
+ description: Performance Monitors Event Type Register 19
7021
+ S3_3_c14_c14_4:
7022
+ name: PMEVTYPER20_EL0
7023
+ description: Performance Monitors Event Type Register 20
7024
+ S3_3_c14_c14_5:
7025
+ name: PMEVTYPER21_EL0
7026
+ description: Performance Monitors Event Type Register 21
7027
+ S3_3_c14_c14_6:
7028
+ name: PMEVTYPER22_EL0
7029
+ description: Performance Monitors Event Type Register 22
7030
+ S3_3_c14_c14_7:
7031
+ name: PMEVTYPER23_EL0
7032
+ description: Performance Monitors Event Type Register 23
7033
+ S3_3_c14_c15_0:
7034
+ name: PMEVTYPER24_EL0
7035
+ description: Performance Monitors Event Type Register 24
7036
+ S3_3_c14_c15_1:
7037
+ name: PMEVTYPER25_EL0
7038
+ description: Performance Monitors Event Type Register 25
7039
+ S3_3_c14_c15_2:
7040
+ name: PMEVTYPER26_EL0
7041
+ description: Performance Monitors Event Type Register 26
7042
+ S3_3_c14_c15_3:
7043
+ name: PMEVTYPER27_EL0
7044
+ description: Performance Monitors Event Type Register 27
7045
+ S3_3_c14_c15_4:
7046
+ name: PMEVTYPER28_EL0
7047
+ description: Performance Monitors Event Type Register 28
7048
+ S3_3_c14_c15_5:
7049
+ name: PMEVTYPER29_EL0
7050
+ description: Performance Monitors Event Type Register 29
7051
+ S3_3_c14_c15_6:
7052
+ name: PMEVTYPER30_EL0
7053
+ description: Performance Monitors Event Type Register 30
7054
+ S3_3_c14_c15_7:
7055
+ name: PMCCFILTR_EL0
7056
+ description: Performance Monitors Cycle Count Filter Register Performance Monitors
7057
+ Event Type Register 31
7058
+ S3_4_c0_c0_0:
7059
+ name: VPIDR_EL2
7060
+ description: Virtualization Processor ID Register
7061
+ S3_4_c0_c0_5:
7062
+ name: VMPIDR_EL2
7063
+ description: Virtualization Multiprocessor ID Register
7064
+ S3_4_c1_c0_0:
7065
+ name: SCTLR_EL2
7066
+ description: System Control Register (EL2)
7067
+ S3_4_c1_c0_1:
7068
+ name: ACTLR_EL2
7069
+ description: Auxiliary Control Register (EL2)
7070
+ S3_4_c1_c1_0:
7071
+ name: HCR_EL2
7072
+ description: Hypervisor Configuration Register
7073
+ S3_4_c1_c1_1:
7074
+ name: MDCR_EL2
7075
+ description: Monitor Debug Configuration Register (EL2)
7076
+ S3_4_c1_c1_2:
7077
+ name: CPTR_EL2
7078
+ description: Architectural Feature Trap Register (EL2)
7079
+ S3_4_c1_c1_3:
7080
+ name: HSTR_EL2
7081
+ description: Hypervisor System Trap Register
7082
+ S3_4_c1_c1_4:
7083
+ name: HFGRTR_EL2
7084
+ description: Hypervisor Fine-Grained Read Trap Register
7085
+ S3_4_c1_c1_5:
7086
+ name: HFGWTR_EL2
7087
+ description: Hypervisor Fine-Grained Write Trap Register
7088
+ S3_4_c1_c1_6:
7089
+ name: HFGITR_EL2
7090
+ description: Hypervisor Fine-Grained Instruction Trap Register
7091
+ S3_4_c1_c1_7:
7092
+ name: HACR_EL2
7093
+ description: Hypervisor Auxiliary Control Register
7094
+ S3_4_c1_c2_0:
7095
+ name: ZCR_EL2
7096
+ description: SVE Control Register for EL2
7097
+ S3_4_c1_c2_1:
7098
+ name: TRFCR_EL2
7099
+ description: Trace Filter Control Register (EL2)
7100
+ S3_4_c1_c3_1:
7101
+ name: SDER32_EL2
7102
+ description: AArch32 Secure Debug Enable Register
7103
+ S3_4_c2_c0_0:
7104
+ name: TTBR0_EL2
7105
+ description: Translation Table Base Register 0 (EL2)
7106
+ S3_4_c2_c0_1:
7107
+ name: TTBR1_EL2
7108
+ description: Translation Table Base Register 1 (EL2)
7109
+ S3_4_c2_c0_2:
7110
+ name: TCR_EL2
7111
+ description: Translation Control Register (EL2)
7112
+ S3_4_c2_c1_0:
7113
+ name: VTTBR_EL2
7114
+ description: Virtualization Translation Table Base Register
7115
+ S3_4_c2_c1_2:
7116
+ name: VTCR_EL2
7117
+ description: Virtualization Translation Control Register
7118
+ S3_4_c2_c2_0:
7119
+ name: VNCR_EL2
7120
+ description: Virtual Nested Control Register
7121
+ S3_4_c2_c6_0:
7122
+ name: VSTTBR_EL2
7123
+ description: Virtualization Secure Translation Table Base Register
7124
+ S3_4_c2_c6_2:
7125
+ name: VSTCR_EL2
7126
+ description: Virtualization Secure Translation Control Register
7127
+ S3_4_c3_c0_0:
7128
+ name: DACR32_EL2
7129
+ description: Domain Access Control Register
7130
+ S3_4_c3_c1_4:
7131
+ name: HDFGRTR_EL2
7132
+ description: Hypervisor Debug Fine-Grained Read Trap Register
7133
+ S3_4_c3_c1_5:
7134
+ name: HDFGWTR_EL2
7135
+ description: Hypervisor Debug Fine-Grained Write Trap Register
7136
+ S3_4_c3_c1_6:
7137
+ name: HAFGRTR_EL2
7138
+ description: Hypervisor Activity Monitors Fine-Grained Read Trap Register
7139
+ S3_4_c4_c0_0:
7140
+ name: SPSR_EL2
7141
+ description: Saved Program Status Register (EL2)
7142
+ S3_4_c4_c0_1:
7143
+ name: ELR_EL2
7144
+ description: Exception Link Register (EL2)
7145
+ S3_4_c4_c1_0:
7146
+ name: SP_EL1
7147
+ description: Stack Pointer (EL1)
7148
+ S3_4_c4_c3_0:
7149
+ name: SPSR_irq
7150
+ description: Saved Program Status Register (IRQ mode)
7151
+ S3_4_c4_c3_1:
7152
+ name: SPSR_abt
7153
+ description: Saved Program Status Register (Abort mode)
7154
+ S3_4_c4_c3_2:
7155
+ name: SPSR_und
7156
+ description: Saved Program Status Register (Undefined mode)
7157
+ S3_4_c4_c3_3:
7158
+ name: SPSR_fiq
7159
+ description: Saved Program Status Register (FIQ mode)
7160
+ S3_4_c5_c0_1:
7161
+ name: IFSR32_EL2
7162
+ description: Instruction Fault Status Register (EL2)
7163
+ S3_4_c5_c1_0:
7164
+ name: AFSR0_EL2
7165
+ description: Auxiliary Fault Status Register 0 (EL2)
7166
+ S3_4_c5_c1_1:
7167
+ name: AFSR1_EL2
7168
+ description: Auxiliary Fault Status Register 1 (EL2)
7169
+ S3_4_c5_c2_0:
7170
+ name: ESR_EL2
7171
+ description: Exception Syndrome Register (EL2)
7172
+ S3_4_c5_c2_3:
7173
+ name: VSESR_EL2
7174
+ description: Virtual SError Exception Syndrome Register
7175
+ S3_4_c5_c3_0:
7176
+ name: FPEXC32_EL2
7177
+ description: Floating-Point Exception Control register
7178
+ S3_4_c5_c6_0:
7179
+ name: TFSR_EL2
7180
+ description: Tag Fault Status Register (EL2)
7181
+ S3_4_c6_c0_0:
7182
+ name: FAR_EL2
7183
+ description: Fault Address Register (EL2)
7184
+ S3_4_c6_c0_4:
7185
+ name: HPFAR_EL2
7186
+ description: Hypervisor IPA Fault Address Register
7187
+ S3_4_c9_c9_0:
7188
+ name: PMSCR_EL2
7189
+ description: Statistical Profiling Control Register (EL2)
7190
+ S3_4_c10_c2_0:
7191
+ name: MAIR_EL2
7192
+ description: Memory Attribute Indirection Register (EL2)
7193
+ S3_4_c10_c3_0:
7194
+ name: AMAIR_EL2
7195
+ description: Auxiliary Memory Attribute Indirection Register (EL2)
7196
+ S3_4_c10_c4_0:
7197
+ name: MPAMHCR_EL2
7198
+ description: MPAM Hypervisor Control Register (EL2)
7199
+ S3_4_c10_c4_1:
7200
+ name: MPAMVPMV_EL2
7201
+ description: MPAM Virtual Partition Mapping Valid Register
7202
+ S3_4_c10_c5_0:
7203
+ name: MPAM2_EL2
7204
+ description: MPAM2 Register (EL2)
7205
+ S3_4_c10_c6_0:
7206
+ name: MPAMVPM0_EL2
7207
+ description: MPAM Virtual PARTID Mapping Register 0
7208
+ S3_4_c10_c6_1:
7209
+ name: MPAMVPM1_EL2
7210
+ description: MPAM Virtual PARTID Mapping Register 1
7211
+ S3_4_c10_c6_2:
7212
+ name: MPAMVPM2_EL2
7213
+ description: MPAM Virtual PARTID Mapping Register 2
7214
+ S3_4_c10_c6_3:
7215
+ name: MPAMVPM3_EL2
7216
+ description: MPAM Virtual PARTID Mapping Register 3
7217
+ S3_4_c10_c6_4:
7218
+ name: MPAMVPM4_EL2
7219
+ description: MPAM Virtual PARTID Mapping Register 4
7220
+ S3_4_c10_c6_5:
7221
+ name: MPAMVPM5_EL2
7222
+ description: MPAM Virtual PARTID Mapping Register 5
7223
+ S3_4_c10_c6_6:
7224
+ name: MPAMVPM6_EL2
7225
+ description: MPAM Virtual PARTID Mapping Register 6
7226
+ S3_4_c10_c6_7:
7227
+ name: MPAMVPM7_EL2
7228
+ description: MPAM Virtual PARTID Mapping Register 7
7229
+ S3_4_c12_c0_0:
7230
+ name: VBAR_EL2
7231
+ description: Vector Base Address Register (EL2)
7232
+ S3_4_c12_c0_1:
7233
+ name: RVBAR_EL2
7234
+ description: Reset Vector Base Address Register (if EL3 not implemented)
7235
+ S3_4_c12_c0_2:
7236
+ name: RMR_EL2
7237
+ description: Reset Management Register (EL2)
7238
+ S3_4_c12_c1_1:
7239
+ name: VDISR_EL2
7240
+ description: Virtual Deferred Interrupt Status Register
7241
+ S3_4_c12_c8_0:
7242
+ name: ICH_AP0R0_EL2
7243
+ description: Interrupt Controller Hyp Active Priorities Group 0 Register 0
7244
+ S3_4_c12_c8_1:
7245
+ name: ICH_AP0R1_EL2
7246
+ description: Interrupt Controller Hyp Active Priorities Group 0 Register 1
7247
+ S3_4_c12_c8_2:
7248
+ name: ICH_AP0R2_EL2
7249
+ description: Interrupt Controller Hyp Active Priorities Group 0 Register 2
7250
+ S3_4_c12_c8_3:
7251
+ name: ICH_AP0R3_EL2
7252
+ description: Interrupt Controller Hyp Active Priorities Group 0 Register 3
7253
+ S3_4_c12_c9_0:
7254
+ name: ICH_AP1R0_EL2
7255
+ description: Interrupt Controller Hyp Active Priorities Group 1 Register 0
7256
+ S3_4_c12_c9_1:
7257
+ name: ICH_AP1R1_EL2
7258
+ description: Interrupt Controller Hyp Active Priorities Group 1 Register 1
7259
+ S3_4_c12_c9_2:
7260
+ name: ICH_AP1R2_EL2
7261
+ description: Interrupt Controller Hyp Active Priorities Group 1 Register 2
7262
+ S3_4_c12_c9_3:
7263
+ name: ICH_AP1R3_EL2
7264
+ description: Interrupt Controller Hyp Active Priorities Group 1 Register 3
7265
+ S3_4_c12_c9_5:
7266
+ name: ICC_SRE_EL2
7267
+ description: Interrupt Controller System Register Enable register (EL2)
7268
+ S3_4_c12_c11_0:
7269
+ name: ICH_HCR_EL2
7270
+ description: Interrupt Controller Hyp Control Register
7271
+ S3_4_c12_c11_1:
7272
+ name: ICH_VTR_EL2
7273
+ description: Interrupt Controller VGIC Type Register
7274
+ S3_4_c12_c11_2:
7275
+ name: ICH_MISR_EL2
7276
+ description: Interrupt Controller Maintenance Interrupt State Register
7277
+ S3_4_c12_c11_3:
7278
+ name: ICH_EISR_EL2
7279
+ description: Interrupt Controller End of Interrupt Status Register
7280
+ S3_4_c12_c11_5:
7281
+ name: ICH_ELRSR_EL2
7282
+ description: Interrupt Controller Empty List Register Status Register
7283
+ S3_4_c12_c11_7:
7284
+ name: ICH_VMCR_EL2
7285
+ description: Interrupt Controller Virtual Machine Control Register
7286
+ S3_4_c12_c12_0:
7287
+ name: ICH_LR0_EL2
7288
+ description: Interrupt Controller List Register 0
7289
+ S3_4_c12_c12_1:
7290
+ name: ICH_LR1_EL2
7291
+ description: Interrupt Controller List Register 1
7292
+ S3_4_c12_c12_2:
7293
+ name: ICH_LR2_EL2
7294
+ description: Interrupt Controller List Register 2
7295
+ S3_4_c12_c12_3:
7296
+ name: ICH_LR3_EL2
7297
+ description: Interrupt Controller List Register 3
7298
+ S3_4_c12_c12_4:
7299
+ name: ICH_LR4_EL2
7300
+ description: Interrupt Controller List Register 4
7301
+ S3_4_c12_c12_5:
7302
+ name: ICH_LR5_EL2
7303
+ description: Interrupt Controller List Register 5
7304
+ S3_4_c12_c12_6:
7305
+ name: ICH_LR6_EL2
7306
+ description: Interrupt Controller List Register 6
7307
+ S3_4_c12_c12_7:
7308
+ name: ICH_LR7_EL2
7309
+ description: Interrupt Controller List Register 7
7310
+ S3_4_c12_c13_0:
7311
+ name: ICH_LR8_EL2
7312
+ description: Interrupt Controller List Register 8
7313
+ S3_4_c12_c13_1:
7314
+ name: ICH_LR9_EL2
7315
+ description: Interrupt Controller List Register 9
7316
+ S3_4_c12_c13_2:
7317
+ name: ICH_LR10_EL2
7318
+ description: Interrupt Controller List Register 10
7319
+ S3_4_c12_c13_3:
7320
+ name: ICH_LR11_EL2
7321
+ description: Interrupt Controller List Register 11
7322
+ S3_4_c12_c13_4:
7323
+ name: ICH_LR12_EL2
7324
+ description: Interrupt Controller List Register 12
7325
+ S3_4_c12_c13_5:
7326
+ name: ICH_LR13_EL2
7327
+ description: Interrupt Controller List Register 13
7328
+ S3_4_c12_c13_6:
7329
+ name: ICH_LR14_EL2
7330
+ description: Interrupt Controller List Register 14
7331
+ S3_4_c12_c13_7:
7332
+ name: ICH_LR15_EL2
7333
+ description: Interrupt Controller List Register 15
7334
+ S3_4_c13_c0_1:
7335
+ name: CONTEXTIDR_EL2
7336
+ description: Context ID Register (EL2)
7337
+ S3_4_c13_c0_2:
7338
+ name: TPIDR_EL2
7339
+ description: EL2 Software Thread ID Register
7340
+ S3_4_c13_c0_7:
7341
+ name: SCXTNUM_EL2
7342
+ description: EL2 Read/Write Software Context Number
7343
+ S3_4_c13_c8_0:
7344
+ name: AMEVCNTVOFF00_EL2
7345
+ description: Activity Monitors Event Counter Virtual Offset Register 0 0
7346
+ S3_4_c13_c8_1:
7347
+ name: AMEVCNTVOFF01_EL2
7348
+ description: Activity Monitors Event Counter Virtual Offset Register 0 1
7349
+ S3_4_c13_c8_2:
7350
+ name: AMEVCNTVOFF02_EL2
7351
+ description: Activity Monitors Event Counter Virtual Offset Register 0 2
7352
+ S3_4_c13_c8_3:
7353
+ name: AMEVCNTVOFF03_EL2
7354
+ description: Activity Monitors Event Counter Virtual Offset Register 0 3
7355
+ S3_4_c13_c8_4:
7356
+ name: AMEVCNTVOFF04_EL2
7357
+ description: Activity Monitors Event Counter Virtual Offset Register 0 4
7358
+ S3_4_c13_c8_5:
7359
+ name: AMEVCNTVOFF05_EL2
7360
+ description: Activity Monitors Event Counter Virtual Offset Register 0 5
7361
+ S3_4_c13_c8_6:
7362
+ name: AMEVCNTVOFF06_EL2
7363
+ description: Activity Monitors Event Counter Virtual Offset Register 0 6
7364
+ S3_4_c13_c8_7:
7365
+ name: AMEVCNTVOFF07_EL2
7366
+ description: Activity Monitors Event Counter Virtual Offset Register 0 7
7367
+ S3_4_c13_c9_0:
7368
+ name: AMEVCNTVOFF08_EL2
7369
+ description: Activity Monitors Event Counter Virtual Offset Register 0 8
7370
+ S3_4_c13_c9_1:
7371
+ name: AMEVCNTVOFF09_EL2
7372
+ description: Activity Monitors Event Counter Virtual Offset Register 0 9
7373
+ S3_4_c13_c9_2:
7374
+ name: AMEVCNTVOFF010_EL2
7375
+ description: Activity Monitors Event Counter Virtual Offset Register 0 10
7376
+ S3_4_c13_c9_3:
7377
+ name: AMEVCNTVOFF011_EL2
7378
+ description: Activity Monitors Event Counter Virtual Offset Register 0 11
7379
+ S3_4_c13_c9_4:
7380
+ name: AMEVCNTVOFF012_EL2
7381
+ description: Activity Monitors Event Counter Virtual Offset Register 0 12
7382
+ S3_4_c13_c9_5:
7383
+ name: AMEVCNTVOFF013_EL2
7384
+ description: Activity Monitors Event Counter Virtual Offset Register 0 13
7385
+ S3_4_c13_c9_6:
7386
+ name: AMEVCNTVOFF014_EL2
7387
+ description: Activity Monitors Event Counter Virtual Offset Register 0 14
7388
+ S3_4_c13_c9_7:
7389
+ name: AMEVCNTVOFF015_EL2
7390
+ description: Activity Monitors Event Counter Virtual Offset Register 0 15
7391
+ S3_4_c13_c10_0:
7392
+ name: AMEVCNTVOFF10_EL2
7393
+ description: Activity Monitors Event Counter Virtual Offset Register 1 0
7394
+ S3_4_c13_c10_1:
7395
+ name: AMEVCNTVOFF11_EL2
7396
+ description: Activity Monitors Event Counter Virtual Offset Register 1 1
7397
+ S3_4_c13_c10_2:
7398
+ name: AMEVCNTVOFF12_EL2
7399
+ description: Activity Monitors Event Counter Virtual Offset Register 1 2
7400
+ S3_4_c13_c10_3:
7401
+ name: AMEVCNTVOFF13_EL2
7402
+ description: Activity Monitors Event Counter Virtual Offset Register 1 3
7403
+ S3_4_c13_c10_4:
7404
+ name: AMEVCNTVOFF14_EL2
7405
+ description: Activity Monitors Event Counter Virtual Offset Register 1 4
7406
+ S3_4_c13_c10_5:
7407
+ name: AMEVCNTVOFF15_EL2
7408
+ description: Activity Monitors Event Counter Virtual Offset Register 1 5
7409
+ S3_4_c13_c10_6:
7410
+ name: AMEVCNTVOFF16_EL2
7411
+ description: Activity Monitors Event Counter Virtual Offset Register 1 6
7412
+ S3_4_c13_c10_7:
7413
+ name: AMEVCNTVOFF17_EL2
7414
+ description: Activity Monitors Event Counter Virtual Offset Register 1 7
7415
+ S3_4_c13_c11_0:
7416
+ name: AMEVCNTVOFF18_EL2
7417
+ description: Activity Monitors Event Counter Virtual Offset Register 1 8
7418
+ S3_4_c13_c11_1:
7419
+ name: AMEVCNTVOFF19_EL2
7420
+ description: Activity Monitors Event Counter Virtual Offset Register 1 9
7421
+ S3_4_c13_c11_2:
7422
+ name: AMEVCNTVOFF110_EL2
7423
+ description: Activity Monitors Event Counter Virtual Offset Register 1 10
7424
+ S3_4_c13_c11_3:
7425
+ name: AMEVCNTVOFF111_EL2
7426
+ description: Activity Monitors Event Counter Virtual Offset Register 1 11
7427
+ S3_4_c13_c11_4:
7428
+ name: AMEVCNTVOFF112_EL2
7429
+ description: Activity Monitors Event Counter Virtual Offset Register 1 12
7430
+ S3_4_c13_c11_5:
7431
+ name: AMEVCNTVOFF113_EL2
7432
+ description: Activity Monitors Event Counter Virtual Offset Register 1 13
7433
+ S3_4_c13_c11_6:
7434
+ name: AMEVCNTVOFF114_EL2
7435
+ description: Activity Monitors Event Counter Virtual Offset Register 1 14
7436
+ S3_4_c13_c11_7:
7437
+ name: AMEVCNTVOFF115_EL2
7438
+ description: Activity Monitors Event Counter Virtual Offset Register 1 15
7439
+ S3_4_c14_c0_3:
7440
+ name: CNTVOFF_EL2
7441
+ description: Counter-timer Virtual Offset register
7442
+ S3_4_c14_c0_6:
7443
+ name: CNTPOFF_EL2
7444
+ description: Counter-timer Physical Offset register
7445
+ S3_4_c14_c1_0:
7446
+ name: CNTHCTL_EL2
7447
+ description: Counter-timer Hypervisor Control register
7448
+ S3_4_c14_c2_0:
7449
+ name: CNTHP_TVAL_EL2
7450
+ description: Counter-timer Physical Timer TimerValue register (EL2)
7451
+ S3_4_c14_c2_1:
7452
+ name: CNTHP_CTL_EL2
7453
+ description: Counter-timer Hypervisor Physical Timer Control register
7454
+ S3_4_c14_c2_2:
7455
+ name: CNTHP_CVAL_EL2
7456
+ description: Counter-timer Physical Timer CompareValue register (EL2)
7457
+ S3_4_c14_c3_0:
7458
+ name: CNTHV_TVAL_EL2
7459
+ description: Counter-timer Virtual Timer TimerValue Register (EL2)
7460
+ S3_4_c14_c3_1:
7461
+ name: CNTHV_CTL_EL2
7462
+ description: Counter-timer Virtual Timer Control register (EL2)
7463
+ S3_4_c14_c3_2:
7464
+ name: CNTHV_CVAL_EL2
7465
+ description: Counter-timer Virtual Timer CompareValue register (EL2)
7466
+ S3_4_c14_c4_0:
7467
+ name: CNTHVS_TVAL_EL2
7468
+ description: Counter-timer Secure Virtual Timer TimerValue register (EL2)
7469
+ S3_4_c14_c4_1:
7470
+ name: CNTHVS_CTL_EL2
7471
+ description: Counter-timer Secure Virtual Timer Control register (EL2)
7472
+ S3_4_c14_c4_2:
7473
+ name: CNTHVS_CVAL_EL2
7474
+ description: Counter-timer Secure Virtual Timer CompareValue register (EL2)
7475
+ S3_4_c14_c5_0:
7476
+ name: CNTHPS_TVAL_EL2
7477
+ description: Counter-timer Secure Physical Timer TimerValue register (EL2)
7478
+ S3_4_c14_c5_1:
7479
+ name: CNTHPS_CTL_EL2
7480
+ description: Counter-timer Secure Physical Timer Control register (EL2)
7481
+ S3_4_c14_c5_2:
7482
+ name: CNTHPS_CVAL_EL2
7483
+ description: Counter-timer Secure Physical Timer CompareValue register (EL2)
7484
+ S3_6_c1_c0_0:
7485
+ name: SCTLR_EL3
7486
+ description: System Control Register (EL3)
7487
+ S3_6_c1_c0_1:
7488
+ name: ACTLR_EL3
7489
+ description: Auxiliary Control Register (EL3)
7490
+ S3_6_c1_c1_0:
7491
+ name: SCR_EL3
7492
+ description: Secure Configuration Register
7493
+ S3_6_c1_c1_1:
7494
+ name: SDER32_EL3
7495
+ description: AArch32 Secure Debug Enable Register
7496
+ S3_6_c1_c1_2:
7497
+ name: CPTR_EL3
7498
+ description: Architectural Feature Trap Register (EL3)
7499
+ S3_6_c1_c2_0:
7500
+ name: ZCR_EL3
7501
+ description: SVE Control Register for EL3
7502
+ S3_6_c1_c3_1:
7503
+ name: MDCR_EL3
7504
+ description: Monitor Debug Configuration Register (EL3)
7505
+ S3_6_c2_c0_0:
7506
+ name: TTBR0_EL3
7507
+ description: Translation Table Base Register 0 (EL3)
7508
+ S3_6_c2_c0_2:
7509
+ name: TCR_EL3
7510
+ description: Translation Control Register (EL3)
7511
+ S3_6_c4_c0_0:
7512
+ name: SPSR_EL3
7513
+ description: Saved Program Status Register (EL3)
7514
+ S3_6_c4_c0_1:
7515
+ name: ELR_EL3
7516
+ description: Exception Link Register (EL3)
7517
+ S3_6_c4_c1_0:
7518
+ name: SP_EL2
7519
+ description: Stack Pointer (EL2)
7520
+ S3_6_c5_c1_0:
7521
+ name: AFSR0_EL3
7522
+ description: Auxiliary Fault Status Register 0 (EL3)
7523
+ S3_6_c5_c1_1:
7524
+ name: AFSR1_EL3
7525
+ description: Auxiliary Fault Status Register 1 (EL3)
7526
+ S3_6_c5_c2_0:
7527
+ name: ESR_EL3
7528
+ description: Exception Syndrome Register (EL3)
7529
+ S3_6_c5_c6_0:
7530
+ name: TFSR_EL3
7531
+ description: Tag Fault Status Register (EL3)
7532
+ S3_6_c6_c0_0:
7533
+ name: FAR_EL3
7534
+ description: Fault Address Register (EL3)
7535
+ S3_6_c10_c2_0:
7536
+ name: MAIR_EL3
7537
+ description: Memory Attribute Indirection Register (EL3)
7538
+ S3_6_c10_c3_0:
7539
+ name: AMAIR_EL3
7540
+ description: Auxiliary Memory Attribute Indirection Register (EL3)
7541
+ S3_6_c10_c5_0:
7542
+ name: MPAM3_EL3
7543
+ description: MPAM3 Register (EL3)
7544
+ S3_6_c12_c0_0:
7545
+ name: VBAR_EL3
7546
+ description: Vector Base Address Register (EL3)
7547
+ S3_6_c12_c0_1:
7548
+ name: RVBAR_EL3
7549
+ description: Reset Vector Base Address Register (if EL3 implemented)
7550
+ S3_6_c12_c0_2:
7551
+ name: RMR_EL3
7552
+ description: Reset Management Register (EL3)
7553
+ S3_6_c12_c12_4:
7554
+ name: ICC_CTLR_EL3
7555
+ description: Interrupt Controller Control Register (EL3)
7556
+ S3_6_c12_c12_5:
7557
+ name: ICC_SRE_EL3
7558
+ description: Interrupt Controller System Register Enable register (EL3)
7559
+ S3_6_c12_c12_7:
7560
+ name: ICC_IGRPEN1_EL3
7561
+ description: Interrupt Controller Interrupt Group 1 Enable register (EL3)
7562
+ S3_6_c13_c0_2:
7563
+ name: TPIDR_EL3
7564
+ description: EL3 Software Thread ID Register
7565
+ S3_6_c13_c0_7:
7566
+ name: SCXTNUM_EL3
7567
+ description: EL3 Read/Write Software Context Number
7568
+ S3_7_c14_c2_0:
7569
+ name: CNTPS_TVAL_EL1
7570
+ description: Counter-timer Physical Secure Timer TimerValue register
7571
+ S3_7_c14_c2_1:
7572
+ name: CNTPS_CTL_EL1
7573
+ description: Counter-timer Physical Secure Timer Control register
7574
+ S3_7_c14_c2_2:
7575
+ name: CNTPS_CVAL_EL1
7576
+ description: Counter-timer Physical Secure Timer CompareValue register
7577
+ pstate:
7578
+ 3: UAO
7579
+ 4: PAN
7580
+ 5: SPSel
7581
+ 6: DAIFSet
7582