winrt-Windows.System.Power 2.0.1__tar.gz → 2.1.0__tar.gz
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- {winrt_windows_system_power-2.0.1 → winrt_windows_system_power-2.1.0}/PKG-INFO +3 -3
- {winrt_windows_system_power-2.0.1 → winrt_windows_system_power-2.1.0}/all-requirements.txt +2 -2
- {winrt_windows_system_power-2.0.1 → winrt_windows_system_power-2.1.0}/py.Windows.System.Power.cpp +264 -275
- winrt_windows_system_power-2.1.0/pywinrt-version.txt +1 -0
- {winrt_windows_system_power-2.0.1 → winrt_windows_system_power-2.1.0}/requirements.txt +2 -2
- winrt_windows_system_power-2.1.0/winrt/_winrt_windows_system_power.pyi +94 -0
- {winrt_windows_system_power-2.0.1 → winrt_windows_system_power-2.1.0}/winrt/windows/system/power/__init__.py +1 -1
- {winrt_windows_system_power-2.0.1 → winrt_windows_system_power-2.1.0}/winrt_Windows.System.Power.egg-info/PKG-INFO +3 -3
- winrt_windows_system_power-2.1.0/winrt_Windows.System.Power.egg-info/requires.txt +4 -0
- winrt_windows_system_power-2.0.1/pywinrt-version.txt +0 -1
- winrt_windows_system_power-2.0.1/winrt/_winrt_windows_system_power.pyi +0 -97
- winrt_windows_system_power-2.0.1/winrt_Windows.System.Power.egg-info/requires.txt +0 -4
- {winrt_windows_system_power-2.0.1 → winrt_windows_system_power-2.1.0}/README.md +0 -0
- {winrt_windows_system_power-2.0.1 → winrt_windows_system_power-2.1.0}/pyproject.toml +0 -0
- {winrt_windows_system_power-2.0.1 → winrt_windows_system_power-2.1.0}/setup.cfg +0 -0
- {winrt_windows_system_power-2.0.1 → winrt_windows_system_power-2.1.0}/setup.py +0 -0
- {winrt_windows_system_power-2.0.1 → winrt_windows_system_power-2.1.0}/winrt/windows/system/power/py.typed +0 -0
- {winrt_windows_system_power-2.0.1 → winrt_windows_system_power-2.1.0}/winrt_Windows.System.Power.egg-info/SOURCES.txt +0 -0
- {winrt_windows_system_power-2.0.1 → winrt_windows_system_power-2.1.0}/winrt_Windows.System.Power.egg-info/dependency_links.txt +0 -0
- {winrt_windows_system_power-2.0.1 → winrt_windows_system_power-2.1.0}/winrt_Windows.System.Power.egg-info/top_level.txt +0 -0
|
@@ -1,6 +1,6 @@
|
|
|
1
1
|
Metadata-Version: 2.1
|
|
2
2
|
Name: winrt-Windows.System.Power
|
|
3
|
-
Version: 2.0
|
|
3
|
+
Version: 2.1.0
|
|
4
4
|
Summary: Python projection of Windows Runtime (WinRT) APIs
|
|
5
5
|
License: MIT
|
|
6
6
|
Project-URL: Documentation, https://pywinrt.readthedocs.io
|
|
@@ -12,9 +12,9 @@ Classifier: Programming Language :: Python :: Implementation :: CPython
|
|
|
12
12
|
Classifier: Intended Audience :: Developers
|
|
13
13
|
Requires-Python: <3.13,>=3.9
|
|
14
14
|
Description-Content-Type: text/markdown
|
|
15
|
-
Requires-Dist: winrt-runtime==2.0
|
|
15
|
+
Requires-Dist: winrt-runtime==2.1.0
|
|
16
16
|
Provides-Extra: all
|
|
17
|
-
Requires-Dist: winrt-Windows.Foundation[all]==2.0
|
|
17
|
+
Requires-Dist: winrt-Windows.Foundation[all]==2.1.0; extra == "all"
|
|
18
18
|
|
|
19
19
|
<!-- warning: Please don't edit this file. It was automatically generated. -->
|
|
20
20
|
|
|
@@ -1,3 +1,3 @@
|
|
|
1
|
-
# WARNING: Please don't edit this file. It was generated by Python/WinRT v2.0
|
|
1
|
+
# WARNING: Please don't edit this file. It was generated by Python/WinRT v2.1.0
|
|
2
2
|
|
|
3
|
-
winrt-Windows.Foundation[all]==2.0
|
|
3
|
+
winrt-Windows.Foundation[all]==2.1.0
|
{winrt_windows_system_power-2.0.1 → winrt_windows_system_power-2.1.0}/py.Windows.System.Power.cpp
RENAMED
|
@@ -1,8 +1,7 @@
|
|
|
1
|
-
// WARNING: Please don't edit this file. It was generated by Python/WinRT v2.0
|
|
1
|
+
// WARNING: Please don't edit this file. It was generated by Python/WinRT v2.1.0
|
|
2
2
|
|
|
3
3
|
#include "py.Windows.System.Power.h"
|
|
4
4
|
|
|
5
|
-
|
|
6
5
|
namespace py::cpp::Windows::System::Power
|
|
7
6
|
{
|
|
8
7
|
// ----- BackgroundEnergyManager class --------------------
|
|
@@ -16,14 +15,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
16
15
|
|
|
17
16
|
static PyObject* BackgroundEnergyManager_get_ExcessiveUsageLevel(PyObject* /*unused*/, void* /*unused*/) noexcept
|
|
18
17
|
{
|
|
19
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.BackgroundEnergyManager", L"ExcessiveUsageLevel"))
|
|
20
|
-
{
|
|
21
|
-
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
22
|
-
return nullptr;
|
|
23
|
-
}
|
|
24
|
-
|
|
25
18
|
try
|
|
26
19
|
{
|
|
20
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.BackgroundEnergyManager", L"ExcessiveUsageLevel"))
|
|
21
|
+
{
|
|
22
|
+
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
23
|
+
return nullptr;
|
|
24
|
+
}
|
|
25
|
+
|
|
27
26
|
return py::convert(winrt::Windows::System::Power::BackgroundEnergyManager::ExcessiveUsageLevel());
|
|
28
27
|
}
|
|
29
28
|
catch (...)
|
|
@@ -35,14 +34,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
35
34
|
|
|
36
35
|
static PyObject* BackgroundEnergyManager_get_LowUsageLevel(PyObject* /*unused*/, void* /*unused*/) noexcept
|
|
37
36
|
{
|
|
38
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.BackgroundEnergyManager", L"LowUsageLevel"))
|
|
39
|
-
{
|
|
40
|
-
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
41
|
-
return nullptr;
|
|
42
|
-
}
|
|
43
|
-
|
|
44
37
|
try
|
|
45
38
|
{
|
|
39
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.BackgroundEnergyManager", L"LowUsageLevel"))
|
|
40
|
+
{
|
|
41
|
+
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
42
|
+
return nullptr;
|
|
43
|
+
}
|
|
44
|
+
|
|
46
45
|
return py::convert(winrt::Windows::System::Power::BackgroundEnergyManager::LowUsageLevel());
|
|
47
46
|
}
|
|
48
47
|
catch (...)
|
|
@@ -54,14 +53,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
54
53
|
|
|
55
54
|
static PyObject* BackgroundEnergyManager_get_MaxAcceptableUsageLevel(PyObject* /*unused*/, void* /*unused*/) noexcept
|
|
56
55
|
{
|
|
57
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.BackgroundEnergyManager", L"MaxAcceptableUsageLevel"))
|
|
58
|
-
{
|
|
59
|
-
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
60
|
-
return nullptr;
|
|
61
|
-
}
|
|
62
|
-
|
|
63
56
|
try
|
|
64
57
|
{
|
|
58
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.BackgroundEnergyManager", L"MaxAcceptableUsageLevel"))
|
|
59
|
+
{
|
|
60
|
+
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
61
|
+
return nullptr;
|
|
62
|
+
}
|
|
63
|
+
|
|
65
64
|
return py::convert(winrt::Windows::System::Power::BackgroundEnergyManager::MaxAcceptableUsageLevel());
|
|
66
65
|
}
|
|
67
66
|
catch (...)
|
|
@@ -73,14 +72,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
73
72
|
|
|
74
73
|
static PyObject* BackgroundEnergyManager_get_NearMaxAcceptableUsageLevel(PyObject* /*unused*/, void* /*unused*/) noexcept
|
|
75
74
|
{
|
|
76
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.BackgroundEnergyManager", L"NearMaxAcceptableUsageLevel"))
|
|
77
|
-
{
|
|
78
|
-
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
79
|
-
return nullptr;
|
|
80
|
-
}
|
|
81
|
-
|
|
82
75
|
try
|
|
83
76
|
{
|
|
77
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.BackgroundEnergyManager", L"NearMaxAcceptableUsageLevel"))
|
|
78
|
+
{
|
|
79
|
+
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
80
|
+
return nullptr;
|
|
81
|
+
}
|
|
82
|
+
|
|
84
83
|
return py::convert(winrt::Windows::System::Power::BackgroundEnergyManager::NearMaxAcceptableUsageLevel());
|
|
85
84
|
}
|
|
86
85
|
catch (...)
|
|
@@ -92,14 +91,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
92
91
|
|
|
93
92
|
static PyObject* BackgroundEnergyManager_get_NearTerminationUsageLevel(PyObject* /*unused*/, void* /*unused*/) noexcept
|
|
94
93
|
{
|
|
95
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.BackgroundEnergyManager", L"NearTerminationUsageLevel"))
|
|
96
|
-
{
|
|
97
|
-
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
98
|
-
return nullptr;
|
|
99
|
-
}
|
|
100
|
-
|
|
101
94
|
try
|
|
102
95
|
{
|
|
96
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.BackgroundEnergyManager", L"NearTerminationUsageLevel"))
|
|
97
|
+
{
|
|
98
|
+
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
99
|
+
return nullptr;
|
|
100
|
+
}
|
|
101
|
+
|
|
103
102
|
return py::convert(winrt::Windows::System::Power::BackgroundEnergyManager::NearTerminationUsageLevel());
|
|
104
103
|
}
|
|
105
104
|
catch (...)
|
|
@@ -111,14 +110,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
111
110
|
|
|
112
111
|
static PyObject* BackgroundEnergyManager_get_RecentEnergyUsage(PyObject* /*unused*/, void* /*unused*/) noexcept
|
|
113
112
|
{
|
|
114
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.BackgroundEnergyManager", L"RecentEnergyUsage"))
|
|
115
|
-
{
|
|
116
|
-
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
117
|
-
return nullptr;
|
|
118
|
-
}
|
|
119
|
-
|
|
120
113
|
try
|
|
121
114
|
{
|
|
115
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.BackgroundEnergyManager", L"RecentEnergyUsage"))
|
|
116
|
+
{
|
|
117
|
+
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
118
|
+
return nullptr;
|
|
119
|
+
}
|
|
120
|
+
|
|
122
121
|
return py::convert(winrt::Windows::System::Power::BackgroundEnergyManager::RecentEnergyUsage());
|
|
123
122
|
}
|
|
124
123
|
catch (...)
|
|
@@ -130,14 +129,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
130
129
|
|
|
131
130
|
static PyObject* BackgroundEnergyManager_get_RecentEnergyUsageLevel(PyObject* /*unused*/, void* /*unused*/) noexcept
|
|
132
131
|
{
|
|
133
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.BackgroundEnergyManager", L"RecentEnergyUsageLevel"))
|
|
134
|
-
{
|
|
135
|
-
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
136
|
-
return nullptr;
|
|
137
|
-
}
|
|
138
|
-
|
|
139
132
|
try
|
|
140
133
|
{
|
|
134
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.BackgroundEnergyManager", L"RecentEnergyUsageLevel"))
|
|
135
|
+
{
|
|
136
|
+
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
137
|
+
return nullptr;
|
|
138
|
+
}
|
|
139
|
+
|
|
141
140
|
return py::convert(winrt::Windows::System::Power::BackgroundEnergyManager::RecentEnergyUsageLevel());
|
|
142
141
|
}
|
|
143
142
|
catch (...)
|
|
@@ -149,14 +148,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
149
148
|
|
|
150
149
|
static PyObject* BackgroundEnergyManager_get_TerminationUsageLevel(PyObject* /*unused*/, void* /*unused*/) noexcept
|
|
151
150
|
{
|
|
152
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.BackgroundEnergyManager", L"TerminationUsageLevel"))
|
|
153
|
-
{
|
|
154
|
-
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
155
|
-
return nullptr;
|
|
156
|
-
}
|
|
157
|
-
|
|
158
151
|
try
|
|
159
152
|
{
|
|
153
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.BackgroundEnergyManager", L"TerminationUsageLevel"))
|
|
154
|
+
{
|
|
155
|
+
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
156
|
+
return nullptr;
|
|
157
|
+
}
|
|
158
|
+
|
|
160
159
|
return py::convert(winrt::Windows::System::Power::BackgroundEnergyManager::TerminationUsageLevel());
|
|
161
160
|
}
|
|
162
161
|
catch (...)
|
|
@@ -168,14 +167,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
168
167
|
|
|
169
168
|
static PyObject* BackgroundEnergyManager_add_RecentEnergyUsageIncreased(PyObject* /*unused*/, PyObject* arg) noexcept
|
|
170
169
|
{
|
|
171
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.BackgroundEnergyManager", L"RecentEnergyUsageIncreased"))
|
|
172
|
-
{
|
|
173
|
-
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
174
|
-
return nullptr;
|
|
175
|
-
}
|
|
176
|
-
|
|
177
170
|
try
|
|
178
171
|
{
|
|
172
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.BackgroundEnergyManager", L"RecentEnergyUsageIncreased"))
|
|
173
|
+
{
|
|
174
|
+
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
175
|
+
return nullptr;
|
|
176
|
+
}
|
|
177
|
+
|
|
179
178
|
auto param0 = py::convert_to<winrt::Windows::Foundation::EventHandler<winrt::Windows::Foundation::IInspectable>>(arg);
|
|
180
179
|
|
|
181
180
|
return py::convert(winrt::Windows::System::Power::BackgroundEnergyManager::RecentEnergyUsageIncreased(param0));
|
|
@@ -189,14 +188,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
189
188
|
|
|
190
189
|
static PyObject* BackgroundEnergyManager_remove_RecentEnergyUsageIncreased(PyObject* /*unused*/, PyObject* arg) noexcept
|
|
191
190
|
{
|
|
192
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.BackgroundEnergyManager", L"RecentEnergyUsageIncreased"))
|
|
193
|
-
{
|
|
194
|
-
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
195
|
-
return nullptr;
|
|
196
|
-
}
|
|
197
|
-
|
|
198
191
|
try
|
|
199
192
|
{
|
|
193
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.BackgroundEnergyManager", L"RecentEnergyUsageIncreased"))
|
|
194
|
+
{
|
|
195
|
+
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
196
|
+
return nullptr;
|
|
197
|
+
}
|
|
198
|
+
|
|
200
199
|
auto param0 = py::convert_to<winrt::event_token>(arg);
|
|
201
200
|
|
|
202
201
|
winrt::Windows::System::Power::BackgroundEnergyManager::RecentEnergyUsageIncreased(param0);
|
|
@@ -211,14 +210,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
211
210
|
|
|
212
211
|
static PyObject* BackgroundEnergyManager_add_RecentEnergyUsageReturnedToLow(PyObject* /*unused*/, PyObject* arg) noexcept
|
|
213
212
|
{
|
|
214
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.BackgroundEnergyManager", L"RecentEnergyUsageReturnedToLow"))
|
|
215
|
-
{
|
|
216
|
-
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
217
|
-
return nullptr;
|
|
218
|
-
}
|
|
219
|
-
|
|
220
213
|
try
|
|
221
214
|
{
|
|
215
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.BackgroundEnergyManager", L"RecentEnergyUsageReturnedToLow"))
|
|
216
|
+
{
|
|
217
|
+
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
218
|
+
return nullptr;
|
|
219
|
+
}
|
|
220
|
+
|
|
222
221
|
auto param0 = py::convert_to<winrt::Windows::Foundation::EventHandler<winrt::Windows::Foundation::IInspectable>>(arg);
|
|
223
222
|
|
|
224
223
|
return py::convert(winrt::Windows::System::Power::BackgroundEnergyManager::RecentEnergyUsageReturnedToLow(param0));
|
|
@@ -232,14 +231,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
232
231
|
|
|
233
232
|
static PyObject* BackgroundEnergyManager_remove_RecentEnergyUsageReturnedToLow(PyObject* /*unused*/, PyObject* arg) noexcept
|
|
234
233
|
{
|
|
235
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.BackgroundEnergyManager", L"RecentEnergyUsageReturnedToLow"))
|
|
236
|
-
{
|
|
237
|
-
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
238
|
-
return nullptr;
|
|
239
|
-
}
|
|
240
|
-
|
|
241
234
|
try
|
|
242
235
|
{
|
|
236
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.BackgroundEnergyManager", L"RecentEnergyUsageReturnedToLow"))
|
|
237
|
+
{
|
|
238
|
+
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
239
|
+
return nullptr;
|
|
240
|
+
}
|
|
241
|
+
|
|
243
242
|
auto param0 = py::convert_to<winrt::event_token>(arg);
|
|
244
243
|
|
|
245
244
|
winrt::Windows::System::Power::BackgroundEnergyManager::RecentEnergyUsageReturnedToLow(param0);
|
|
@@ -253,10 +252,6 @@ namespace py::cpp::Windows::System::Power
|
|
|
253
252
|
}
|
|
254
253
|
|
|
255
254
|
static PyMethodDef _methods_BackgroundEnergyManager[] = {
|
|
256
|
-
{ "add_recent_energy_usage_increased", reinterpret_cast<PyCFunction>(BackgroundEnergyManager_add_RecentEnergyUsageIncreased), METH_O | METH_STATIC, nullptr },
|
|
257
|
-
{ "remove_recent_energy_usage_increased", reinterpret_cast<PyCFunction>(BackgroundEnergyManager_remove_RecentEnergyUsageIncreased), METH_O | METH_STATIC, nullptr },
|
|
258
|
-
{ "add_recent_energy_usage_returned_to_low", reinterpret_cast<PyCFunction>(BackgroundEnergyManager_add_RecentEnergyUsageReturnedToLow), METH_O | METH_STATIC, nullptr },
|
|
259
|
-
{ "remove_recent_energy_usage_returned_to_low", reinterpret_cast<PyCFunction>(BackgroundEnergyManager_remove_RecentEnergyUsageReturnedToLow), METH_O | METH_STATIC, nullptr },
|
|
260
255
|
{ }
|
|
261
256
|
};
|
|
262
257
|
|
|
@@ -264,22 +259,19 @@ namespace py::cpp::Windows::System::Power
|
|
|
264
259
|
{ }
|
|
265
260
|
};
|
|
266
261
|
|
|
267
|
-
static PyType_Slot _type_slots_BackgroundEnergyManager[] =
|
|
268
|
-
{
|
|
262
|
+
static PyType_Slot _type_slots_BackgroundEnergyManager[] = {
|
|
269
263
|
{ Py_tp_new, reinterpret_cast<void*>(_new_BackgroundEnergyManager) },
|
|
270
264
|
{ Py_tp_methods, reinterpret_cast<void*>(_methods_BackgroundEnergyManager) },
|
|
271
265
|
{ Py_tp_getset, reinterpret_cast<void*>(_getset_BackgroundEnergyManager) },
|
|
272
|
-
{ }
|
|
266
|
+
{ }
|
|
273
267
|
};
|
|
274
268
|
|
|
275
|
-
static PyType_Spec type_spec_BackgroundEnergyManager =
|
|
276
|
-
{
|
|
269
|
+
static PyType_Spec type_spec_BackgroundEnergyManager = {
|
|
277
270
|
"winrt._winrt_windows_system_power.BackgroundEnergyManager",
|
|
278
271
|
0,
|
|
279
272
|
0,
|
|
280
273
|
Py_TPFLAGS_DEFAULT,
|
|
281
|
-
_type_slots_BackgroundEnergyManager
|
|
282
|
-
};
|
|
274
|
+
_type_slots_BackgroundEnergyManager};
|
|
283
275
|
|
|
284
276
|
static PyGetSetDef getset_BackgroundEnergyManager_Static[] = {
|
|
285
277
|
{ "excessive_usage_level", reinterpret_cast<getter>(BackgroundEnergyManager_get_ExcessiveUsageLevel), nullptr, nullptr, nullptr },
|
|
@@ -294,6 +286,10 @@ namespace py::cpp::Windows::System::Power
|
|
|
294
286
|
};
|
|
295
287
|
|
|
296
288
|
static PyMethodDef methods_BackgroundEnergyManager_Static[] = {
|
|
289
|
+
{ "add_recent_energy_usage_increased", reinterpret_cast<PyCFunction>(BackgroundEnergyManager_add_RecentEnergyUsageIncreased), METH_O, nullptr },
|
|
290
|
+
{ "remove_recent_energy_usage_increased", reinterpret_cast<PyCFunction>(BackgroundEnergyManager_remove_RecentEnergyUsageIncreased), METH_O, nullptr },
|
|
291
|
+
{ "add_recent_energy_usage_returned_to_low", reinterpret_cast<PyCFunction>(BackgroundEnergyManager_add_RecentEnergyUsageReturnedToLow), METH_O, nullptr },
|
|
292
|
+
{ "remove_recent_energy_usage_returned_to_low", reinterpret_cast<PyCFunction>(BackgroundEnergyManager_remove_RecentEnergyUsageReturnedToLow), METH_O, nullptr },
|
|
297
293
|
{ }
|
|
298
294
|
};
|
|
299
295
|
|
|
@@ -325,14 +321,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
325
321
|
|
|
326
322
|
static PyObject* ForegroundEnergyManager_get_ExcessiveUsageLevel(PyObject* /*unused*/, void* /*unused*/) noexcept
|
|
327
323
|
{
|
|
328
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.ForegroundEnergyManager", L"ExcessiveUsageLevel"))
|
|
329
|
-
{
|
|
330
|
-
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
331
|
-
return nullptr;
|
|
332
|
-
}
|
|
333
|
-
|
|
334
324
|
try
|
|
335
325
|
{
|
|
326
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.ForegroundEnergyManager", L"ExcessiveUsageLevel"))
|
|
327
|
+
{
|
|
328
|
+
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
329
|
+
return nullptr;
|
|
330
|
+
}
|
|
331
|
+
|
|
336
332
|
return py::convert(winrt::Windows::System::Power::ForegroundEnergyManager::ExcessiveUsageLevel());
|
|
337
333
|
}
|
|
338
334
|
catch (...)
|
|
@@ -344,14 +340,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
344
340
|
|
|
345
341
|
static PyObject* ForegroundEnergyManager_get_LowUsageLevel(PyObject* /*unused*/, void* /*unused*/) noexcept
|
|
346
342
|
{
|
|
347
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.ForegroundEnergyManager", L"LowUsageLevel"))
|
|
348
|
-
{
|
|
349
|
-
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
350
|
-
return nullptr;
|
|
351
|
-
}
|
|
352
|
-
|
|
353
343
|
try
|
|
354
344
|
{
|
|
345
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.ForegroundEnergyManager", L"LowUsageLevel"))
|
|
346
|
+
{
|
|
347
|
+
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
348
|
+
return nullptr;
|
|
349
|
+
}
|
|
350
|
+
|
|
355
351
|
return py::convert(winrt::Windows::System::Power::ForegroundEnergyManager::LowUsageLevel());
|
|
356
352
|
}
|
|
357
353
|
catch (...)
|
|
@@ -363,14 +359,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
363
359
|
|
|
364
360
|
static PyObject* ForegroundEnergyManager_get_MaxAcceptableUsageLevel(PyObject* /*unused*/, void* /*unused*/) noexcept
|
|
365
361
|
{
|
|
366
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.ForegroundEnergyManager", L"MaxAcceptableUsageLevel"))
|
|
367
|
-
{
|
|
368
|
-
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
369
|
-
return nullptr;
|
|
370
|
-
}
|
|
371
|
-
|
|
372
362
|
try
|
|
373
363
|
{
|
|
364
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.ForegroundEnergyManager", L"MaxAcceptableUsageLevel"))
|
|
365
|
+
{
|
|
366
|
+
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
367
|
+
return nullptr;
|
|
368
|
+
}
|
|
369
|
+
|
|
374
370
|
return py::convert(winrt::Windows::System::Power::ForegroundEnergyManager::MaxAcceptableUsageLevel());
|
|
375
371
|
}
|
|
376
372
|
catch (...)
|
|
@@ -382,14 +378,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
382
378
|
|
|
383
379
|
static PyObject* ForegroundEnergyManager_get_NearMaxAcceptableUsageLevel(PyObject* /*unused*/, void* /*unused*/) noexcept
|
|
384
380
|
{
|
|
385
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.ForegroundEnergyManager", L"NearMaxAcceptableUsageLevel"))
|
|
386
|
-
{
|
|
387
|
-
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
388
|
-
return nullptr;
|
|
389
|
-
}
|
|
390
|
-
|
|
391
381
|
try
|
|
392
382
|
{
|
|
383
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.ForegroundEnergyManager", L"NearMaxAcceptableUsageLevel"))
|
|
384
|
+
{
|
|
385
|
+
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
386
|
+
return nullptr;
|
|
387
|
+
}
|
|
388
|
+
|
|
393
389
|
return py::convert(winrt::Windows::System::Power::ForegroundEnergyManager::NearMaxAcceptableUsageLevel());
|
|
394
390
|
}
|
|
395
391
|
catch (...)
|
|
@@ -401,14 +397,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
401
397
|
|
|
402
398
|
static PyObject* ForegroundEnergyManager_get_RecentEnergyUsage(PyObject* /*unused*/, void* /*unused*/) noexcept
|
|
403
399
|
{
|
|
404
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.ForegroundEnergyManager", L"RecentEnergyUsage"))
|
|
405
|
-
{
|
|
406
|
-
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
407
|
-
return nullptr;
|
|
408
|
-
}
|
|
409
|
-
|
|
410
400
|
try
|
|
411
401
|
{
|
|
402
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.ForegroundEnergyManager", L"RecentEnergyUsage"))
|
|
403
|
+
{
|
|
404
|
+
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
405
|
+
return nullptr;
|
|
406
|
+
}
|
|
407
|
+
|
|
412
408
|
return py::convert(winrt::Windows::System::Power::ForegroundEnergyManager::RecentEnergyUsage());
|
|
413
409
|
}
|
|
414
410
|
catch (...)
|
|
@@ -420,14 +416,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
420
416
|
|
|
421
417
|
static PyObject* ForegroundEnergyManager_get_RecentEnergyUsageLevel(PyObject* /*unused*/, void* /*unused*/) noexcept
|
|
422
418
|
{
|
|
423
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.ForegroundEnergyManager", L"RecentEnergyUsageLevel"))
|
|
424
|
-
{
|
|
425
|
-
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
426
|
-
return nullptr;
|
|
427
|
-
}
|
|
428
|
-
|
|
429
419
|
try
|
|
430
420
|
{
|
|
421
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.ForegroundEnergyManager", L"RecentEnergyUsageLevel"))
|
|
422
|
+
{
|
|
423
|
+
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
424
|
+
return nullptr;
|
|
425
|
+
}
|
|
426
|
+
|
|
431
427
|
return py::convert(winrt::Windows::System::Power::ForegroundEnergyManager::RecentEnergyUsageLevel());
|
|
432
428
|
}
|
|
433
429
|
catch (...)
|
|
@@ -439,14 +435,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
439
435
|
|
|
440
436
|
static PyObject* ForegroundEnergyManager_add_RecentEnergyUsageIncreased(PyObject* /*unused*/, PyObject* arg) noexcept
|
|
441
437
|
{
|
|
442
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.ForegroundEnergyManager", L"RecentEnergyUsageIncreased"))
|
|
443
|
-
{
|
|
444
|
-
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
445
|
-
return nullptr;
|
|
446
|
-
}
|
|
447
|
-
|
|
448
438
|
try
|
|
449
439
|
{
|
|
440
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.ForegroundEnergyManager", L"RecentEnergyUsageIncreased"))
|
|
441
|
+
{
|
|
442
|
+
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
443
|
+
return nullptr;
|
|
444
|
+
}
|
|
445
|
+
|
|
450
446
|
auto param0 = py::convert_to<winrt::Windows::Foundation::EventHandler<winrt::Windows::Foundation::IInspectable>>(arg);
|
|
451
447
|
|
|
452
448
|
return py::convert(winrt::Windows::System::Power::ForegroundEnergyManager::RecentEnergyUsageIncreased(param0));
|
|
@@ -460,14 +456,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
460
456
|
|
|
461
457
|
static PyObject* ForegroundEnergyManager_remove_RecentEnergyUsageIncreased(PyObject* /*unused*/, PyObject* arg) noexcept
|
|
462
458
|
{
|
|
463
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.ForegroundEnergyManager", L"RecentEnergyUsageIncreased"))
|
|
464
|
-
{
|
|
465
|
-
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
466
|
-
return nullptr;
|
|
467
|
-
}
|
|
468
|
-
|
|
469
459
|
try
|
|
470
460
|
{
|
|
461
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.ForegroundEnergyManager", L"RecentEnergyUsageIncreased"))
|
|
462
|
+
{
|
|
463
|
+
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
464
|
+
return nullptr;
|
|
465
|
+
}
|
|
466
|
+
|
|
471
467
|
auto param0 = py::convert_to<winrt::event_token>(arg);
|
|
472
468
|
|
|
473
469
|
winrt::Windows::System::Power::ForegroundEnergyManager::RecentEnergyUsageIncreased(param0);
|
|
@@ -482,14 +478,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
482
478
|
|
|
483
479
|
static PyObject* ForegroundEnergyManager_add_RecentEnergyUsageReturnedToLow(PyObject* /*unused*/, PyObject* arg) noexcept
|
|
484
480
|
{
|
|
485
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.ForegroundEnergyManager", L"RecentEnergyUsageReturnedToLow"))
|
|
486
|
-
{
|
|
487
|
-
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
488
|
-
return nullptr;
|
|
489
|
-
}
|
|
490
|
-
|
|
491
481
|
try
|
|
492
482
|
{
|
|
483
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.ForegroundEnergyManager", L"RecentEnergyUsageReturnedToLow"))
|
|
484
|
+
{
|
|
485
|
+
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
486
|
+
return nullptr;
|
|
487
|
+
}
|
|
488
|
+
|
|
493
489
|
auto param0 = py::convert_to<winrt::Windows::Foundation::EventHandler<winrt::Windows::Foundation::IInspectable>>(arg);
|
|
494
490
|
|
|
495
491
|
return py::convert(winrt::Windows::System::Power::ForegroundEnergyManager::RecentEnergyUsageReturnedToLow(param0));
|
|
@@ -503,14 +499,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
503
499
|
|
|
504
500
|
static PyObject* ForegroundEnergyManager_remove_RecentEnergyUsageReturnedToLow(PyObject* /*unused*/, PyObject* arg) noexcept
|
|
505
501
|
{
|
|
506
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.ForegroundEnergyManager", L"RecentEnergyUsageReturnedToLow"))
|
|
507
|
-
{
|
|
508
|
-
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
509
|
-
return nullptr;
|
|
510
|
-
}
|
|
511
|
-
|
|
512
502
|
try
|
|
513
503
|
{
|
|
504
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.ForegroundEnergyManager", L"RecentEnergyUsageReturnedToLow"))
|
|
505
|
+
{
|
|
506
|
+
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
507
|
+
return nullptr;
|
|
508
|
+
}
|
|
509
|
+
|
|
514
510
|
auto param0 = py::convert_to<winrt::event_token>(arg);
|
|
515
511
|
|
|
516
512
|
winrt::Windows::System::Power::ForegroundEnergyManager::RecentEnergyUsageReturnedToLow(param0);
|
|
@@ -524,10 +520,6 @@ namespace py::cpp::Windows::System::Power
|
|
|
524
520
|
}
|
|
525
521
|
|
|
526
522
|
static PyMethodDef _methods_ForegroundEnergyManager[] = {
|
|
527
|
-
{ "add_recent_energy_usage_increased", reinterpret_cast<PyCFunction>(ForegroundEnergyManager_add_RecentEnergyUsageIncreased), METH_O | METH_STATIC, nullptr },
|
|
528
|
-
{ "remove_recent_energy_usage_increased", reinterpret_cast<PyCFunction>(ForegroundEnergyManager_remove_RecentEnergyUsageIncreased), METH_O | METH_STATIC, nullptr },
|
|
529
|
-
{ "add_recent_energy_usage_returned_to_low", reinterpret_cast<PyCFunction>(ForegroundEnergyManager_add_RecentEnergyUsageReturnedToLow), METH_O | METH_STATIC, nullptr },
|
|
530
|
-
{ "remove_recent_energy_usage_returned_to_low", reinterpret_cast<PyCFunction>(ForegroundEnergyManager_remove_RecentEnergyUsageReturnedToLow), METH_O | METH_STATIC, nullptr },
|
|
531
523
|
{ }
|
|
532
524
|
};
|
|
533
525
|
|
|
@@ -535,22 +527,19 @@ namespace py::cpp::Windows::System::Power
|
|
|
535
527
|
{ }
|
|
536
528
|
};
|
|
537
529
|
|
|
538
|
-
static PyType_Slot _type_slots_ForegroundEnergyManager[] =
|
|
539
|
-
{
|
|
530
|
+
static PyType_Slot _type_slots_ForegroundEnergyManager[] = {
|
|
540
531
|
{ Py_tp_new, reinterpret_cast<void*>(_new_ForegroundEnergyManager) },
|
|
541
532
|
{ Py_tp_methods, reinterpret_cast<void*>(_methods_ForegroundEnergyManager) },
|
|
542
533
|
{ Py_tp_getset, reinterpret_cast<void*>(_getset_ForegroundEnergyManager) },
|
|
543
|
-
{ }
|
|
534
|
+
{ }
|
|
544
535
|
};
|
|
545
536
|
|
|
546
|
-
static PyType_Spec type_spec_ForegroundEnergyManager =
|
|
547
|
-
{
|
|
537
|
+
static PyType_Spec type_spec_ForegroundEnergyManager = {
|
|
548
538
|
"winrt._winrt_windows_system_power.ForegroundEnergyManager",
|
|
549
539
|
0,
|
|
550
540
|
0,
|
|
551
541
|
Py_TPFLAGS_DEFAULT,
|
|
552
|
-
_type_slots_ForegroundEnergyManager
|
|
553
|
-
};
|
|
542
|
+
_type_slots_ForegroundEnergyManager};
|
|
554
543
|
|
|
555
544
|
static PyGetSetDef getset_ForegroundEnergyManager_Static[] = {
|
|
556
545
|
{ "excessive_usage_level", reinterpret_cast<getter>(ForegroundEnergyManager_get_ExcessiveUsageLevel), nullptr, nullptr, nullptr },
|
|
@@ -563,6 +552,10 @@ namespace py::cpp::Windows::System::Power
|
|
|
563
552
|
};
|
|
564
553
|
|
|
565
554
|
static PyMethodDef methods_ForegroundEnergyManager_Static[] = {
|
|
555
|
+
{ "add_recent_energy_usage_increased", reinterpret_cast<PyCFunction>(ForegroundEnergyManager_add_RecentEnergyUsageIncreased), METH_O, nullptr },
|
|
556
|
+
{ "remove_recent_energy_usage_increased", reinterpret_cast<PyCFunction>(ForegroundEnergyManager_remove_RecentEnergyUsageIncreased), METH_O, nullptr },
|
|
557
|
+
{ "add_recent_energy_usage_returned_to_low", reinterpret_cast<PyCFunction>(ForegroundEnergyManager_add_RecentEnergyUsageReturnedToLow), METH_O, nullptr },
|
|
558
|
+
{ "remove_recent_energy_usage_returned_to_low", reinterpret_cast<PyCFunction>(ForegroundEnergyManager_remove_RecentEnergyUsageReturnedToLow), METH_O, nullptr },
|
|
566
559
|
{ }
|
|
567
560
|
};
|
|
568
561
|
|
|
@@ -594,14 +587,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
594
587
|
|
|
595
588
|
static PyObject* PowerManager_get_BatteryStatus(PyObject* /*unused*/, void* /*unused*/) noexcept
|
|
596
589
|
{
|
|
597
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.PowerManager", L"BatteryStatus"))
|
|
598
|
-
{
|
|
599
|
-
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
600
|
-
return nullptr;
|
|
601
|
-
}
|
|
602
|
-
|
|
603
590
|
try
|
|
604
591
|
{
|
|
592
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.PowerManager", L"BatteryStatus"))
|
|
593
|
+
{
|
|
594
|
+
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
595
|
+
return nullptr;
|
|
596
|
+
}
|
|
597
|
+
|
|
605
598
|
return py::convert(winrt::Windows::System::Power::PowerManager::BatteryStatus());
|
|
606
599
|
}
|
|
607
600
|
catch (...)
|
|
@@ -613,14 +606,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
613
606
|
|
|
614
607
|
static PyObject* PowerManager_get_EnergySaverStatus(PyObject* /*unused*/, void* /*unused*/) noexcept
|
|
615
608
|
{
|
|
616
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.PowerManager", L"EnergySaverStatus"))
|
|
617
|
-
{
|
|
618
|
-
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
619
|
-
return nullptr;
|
|
620
|
-
}
|
|
621
|
-
|
|
622
609
|
try
|
|
623
610
|
{
|
|
611
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.PowerManager", L"EnergySaverStatus"))
|
|
612
|
+
{
|
|
613
|
+
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
614
|
+
return nullptr;
|
|
615
|
+
}
|
|
616
|
+
|
|
624
617
|
return py::convert(winrt::Windows::System::Power::PowerManager::EnergySaverStatus());
|
|
625
618
|
}
|
|
626
619
|
catch (...)
|
|
@@ -632,14 +625,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
632
625
|
|
|
633
626
|
static PyObject* PowerManager_get_PowerSupplyStatus(PyObject* /*unused*/, void* /*unused*/) noexcept
|
|
634
627
|
{
|
|
635
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.PowerManager", L"PowerSupplyStatus"))
|
|
636
|
-
{
|
|
637
|
-
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
638
|
-
return nullptr;
|
|
639
|
-
}
|
|
640
|
-
|
|
641
628
|
try
|
|
642
629
|
{
|
|
630
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.PowerManager", L"PowerSupplyStatus"))
|
|
631
|
+
{
|
|
632
|
+
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
633
|
+
return nullptr;
|
|
634
|
+
}
|
|
635
|
+
|
|
643
636
|
return py::convert(winrt::Windows::System::Power::PowerManager::PowerSupplyStatus());
|
|
644
637
|
}
|
|
645
638
|
catch (...)
|
|
@@ -651,14 +644,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
651
644
|
|
|
652
645
|
static PyObject* PowerManager_get_RemainingChargePercent(PyObject* /*unused*/, void* /*unused*/) noexcept
|
|
653
646
|
{
|
|
654
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.PowerManager", L"RemainingChargePercent"))
|
|
655
|
-
{
|
|
656
|
-
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
657
|
-
return nullptr;
|
|
658
|
-
}
|
|
659
|
-
|
|
660
647
|
try
|
|
661
648
|
{
|
|
649
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.PowerManager", L"RemainingChargePercent"))
|
|
650
|
+
{
|
|
651
|
+
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
652
|
+
return nullptr;
|
|
653
|
+
}
|
|
654
|
+
|
|
662
655
|
return py::convert(winrt::Windows::System::Power::PowerManager::RemainingChargePercent());
|
|
663
656
|
}
|
|
664
657
|
catch (...)
|
|
@@ -670,14 +663,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
670
663
|
|
|
671
664
|
static PyObject* PowerManager_get_RemainingDischargeTime(PyObject* /*unused*/, void* /*unused*/) noexcept
|
|
672
665
|
{
|
|
673
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.PowerManager", L"RemainingDischargeTime"))
|
|
674
|
-
{
|
|
675
|
-
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
676
|
-
return nullptr;
|
|
677
|
-
}
|
|
678
|
-
|
|
679
666
|
try
|
|
680
667
|
{
|
|
668
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsPropertyPresent(L"Windows.System.Power.PowerManager", L"RemainingDischargeTime"))
|
|
669
|
+
{
|
|
670
|
+
PyErr_SetString(PyExc_AttributeError, "property is not available in this version of Windows");
|
|
671
|
+
return nullptr;
|
|
672
|
+
}
|
|
673
|
+
|
|
681
674
|
return py::convert(winrt::Windows::System::Power::PowerManager::RemainingDischargeTime());
|
|
682
675
|
}
|
|
683
676
|
catch (...)
|
|
@@ -689,14 +682,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
689
682
|
|
|
690
683
|
static PyObject* PowerManager_add_BatteryStatusChanged(PyObject* /*unused*/, PyObject* arg) noexcept
|
|
691
684
|
{
|
|
692
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.PowerManager", L"BatteryStatusChanged"))
|
|
693
|
-
{
|
|
694
|
-
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
695
|
-
return nullptr;
|
|
696
|
-
}
|
|
697
|
-
|
|
698
685
|
try
|
|
699
686
|
{
|
|
687
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.PowerManager", L"BatteryStatusChanged"))
|
|
688
|
+
{
|
|
689
|
+
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
690
|
+
return nullptr;
|
|
691
|
+
}
|
|
692
|
+
|
|
700
693
|
auto param0 = py::convert_to<winrt::Windows::Foundation::EventHandler<winrt::Windows::Foundation::IInspectable>>(arg);
|
|
701
694
|
|
|
702
695
|
return py::convert(winrt::Windows::System::Power::PowerManager::BatteryStatusChanged(param0));
|
|
@@ -710,14 +703,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
710
703
|
|
|
711
704
|
static PyObject* PowerManager_remove_BatteryStatusChanged(PyObject* /*unused*/, PyObject* arg) noexcept
|
|
712
705
|
{
|
|
713
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.PowerManager", L"BatteryStatusChanged"))
|
|
714
|
-
{
|
|
715
|
-
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
716
|
-
return nullptr;
|
|
717
|
-
}
|
|
718
|
-
|
|
719
706
|
try
|
|
720
707
|
{
|
|
708
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.PowerManager", L"BatteryStatusChanged"))
|
|
709
|
+
{
|
|
710
|
+
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
711
|
+
return nullptr;
|
|
712
|
+
}
|
|
713
|
+
|
|
721
714
|
auto param0 = py::convert_to<winrt::event_token>(arg);
|
|
722
715
|
|
|
723
716
|
winrt::Windows::System::Power::PowerManager::BatteryStatusChanged(param0);
|
|
@@ -732,14 +725,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
732
725
|
|
|
733
726
|
static PyObject* PowerManager_add_EnergySaverStatusChanged(PyObject* /*unused*/, PyObject* arg) noexcept
|
|
734
727
|
{
|
|
735
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.PowerManager", L"EnergySaverStatusChanged"))
|
|
736
|
-
{
|
|
737
|
-
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
738
|
-
return nullptr;
|
|
739
|
-
}
|
|
740
|
-
|
|
741
728
|
try
|
|
742
729
|
{
|
|
730
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.PowerManager", L"EnergySaverStatusChanged"))
|
|
731
|
+
{
|
|
732
|
+
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
733
|
+
return nullptr;
|
|
734
|
+
}
|
|
735
|
+
|
|
743
736
|
auto param0 = py::convert_to<winrt::Windows::Foundation::EventHandler<winrt::Windows::Foundation::IInspectable>>(arg);
|
|
744
737
|
|
|
745
738
|
return py::convert(winrt::Windows::System::Power::PowerManager::EnergySaverStatusChanged(param0));
|
|
@@ -753,14 +746,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
753
746
|
|
|
754
747
|
static PyObject* PowerManager_remove_EnergySaverStatusChanged(PyObject* /*unused*/, PyObject* arg) noexcept
|
|
755
748
|
{
|
|
756
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.PowerManager", L"EnergySaverStatusChanged"))
|
|
757
|
-
{
|
|
758
|
-
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
759
|
-
return nullptr;
|
|
760
|
-
}
|
|
761
|
-
|
|
762
749
|
try
|
|
763
750
|
{
|
|
751
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.PowerManager", L"EnergySaverStatusChanged"))
|
|
752
|
+
{
|
|
753
|
+
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
754
|
+
return nullptr;
|
|
755
|
+
}
|
|
756
|
+
|
|
764
757
|
auto param0 = py::convert_to<winrt::event_token>(arg);
|
|
765
758
|
|
|
766
759
|
winrt::Windows::System::Power::PowerManager::EnergySaverStatusChanged(param0);
|
|
@@ -775,14 +768,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
775
768
|
|
|
776
769
|
static PyObject* PowerManager_add_PowerSupplyStatusChanged(PyObject* /*unused*/, PyObject* arg) noexcept
|
|
777
770
|
{
|
|
778
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.PowerManager", L"PowerSupplyStatusChanged"))
|
|
779
|
-
{
|
|
780
|
-
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
781
|
-
return nullptr;
|
|
782
|
-
}
|
|
783
|
-
|
|
784
771
|
try
|
|
785
772
|
{
|
|
773
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.PowerManager", L"PowerSupplyStatusChanged"))
|
|
774
|
+
{
|
|
775
|
+
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
776
|
+
return nullptr;
|
|
777
|
+
}
|
|
778
|
+
|
|
786
779
|
auto param0 = py::convert_to<winrt::Windows::Foundation::EventHandler<winrt::Windows::Foundation::IInspectable>>(arg);
|
|
787
780
|
|
|
788
781
|
return py::convert(winrt::Windows::System::Power::PowerManager::PowerSupplyStatusChanged(param0));
|
|
@@ -796,14 +789,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
796
789
|
|
|
797
790
|
static PyObject* PowerManager_remove_PowerSupplyStatusChanged(PyObject* /*unused*/, PyObject* arg) noexcept
|
|
798
791
|
{
|
|
799
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.PowerManager", L"PowerSupplyStatusChanged"))
|
|
800
|
-
{
|
|
801
|
-
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
802
|
-
return nullptr;
|
|
803
|
-
}
|
|
804
|
-
|
|
805
792
|
try
|
|
806
793
|
{
|
|
794
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.PowerManager", L"PowerSupplyStatusChanged"))
|
|
795
|
+
{
|
|
796
|
+
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
797
|
+
return nullptr;
|
|
798
|
+
}
|
|
799
|
+
|
|
807
800
|
auto param0 = py::convert_to<winrt::event_token>(arg);
|
|
808
801
|
|
|
809
802
|
winrt::Windows::System::Power::PowerManager::PowerSupplyStatusChanged(param0);
|
|
@@ -818,14 +811,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
818
811
|
|
|
819
812
|
static PyObject* PowerManager_add_RemainingChargePercentChanged(PyObject* /*unused*/, PyObject* arg) noexcept
|
|
820
813
|
{
|
|
821
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.PowerManager", L"RemainingChargePercentChanged"))
|
|
822
|
-
{
|
|
823
|
-
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
824
|
-
return nullptr;
|
|
825
|
-
}
|
|
826
|
-
|
|
827
814
|
try
|
|
828
815
|
{
|
|
816
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.PowerManager", L"RemainingChargePercentChanged"))
|
|
817
|
+
{
|
|
818
|
+
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
819
|
+
return nullptr;
|
|
820
|
+
}
|
|
821
|
+
|
|
829
822
|
auto param0 = py::convert_to<winrt::Windows::Foundation::EventHandler<winrt::Windows::Foundation::IInspectable>>(arg);
|
|
830
823
|
|
|
831
824
|
return py::convert(winrt::Windows::System::Power::PowerManager::RemainingChargePercentChanged(param0));
|
|
@@ -839,14 +832,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
839
832
|
|
|
840
833
|
static PyObject* PowerManager_remove_RemainingChargePercentChanged(PyObject* /*unused*/, PyObject* arg) noexcept
|
|
841
834
|
{
|
|
842
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.PowerManager", L"RemainingChargePercentChanged"))
|
|
843
|
-
{
|
|
844
|
-
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
845
|
-
return nullptr;
|
|
846
|
-
}
|
|
847
|
-
|
|
848
835
|
try
|
|
849
836
|
{
|
|
837
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.PowerManager", L"RemainingChargePercentChanged"))
|
|
838
|
+
{
|
|
839
|
+
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
840
|
+
return nullptr;
|
|
841
|
+
}
|
|
842
|
+
|
|
850
843
|
auto param0 = py::convert_to<winrt::event_token>(arg);
|
|
851
844
|
|
|
852
845
|
winrt::Windows::System::Power::PowerManager::RemainingChargePercentChanged(param0);
|
|
@@ -861,14 +854,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
861
854
|
|
|
862
855
|
static PyObject* PowerManager_add_RemainingDischargeTimeChanged(PyObject* /*unused*/, PyObject* arg) noexcept
|
|
863
856
|
{
|
|
864
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.PowerManager", L"RemainingDischargeTimeChanged"))
|
|
865
|
-
{
|
|
866
|
-
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
867
|
-
return nullptr;
|
|
868
|
-
}
|
|
869
|
-
|
|
870
857
|
try
|
|
871
858
|
{
|
|
859
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.PowerManager", L"RemainingDischargeTimeChanged"))
|
|
860
|
+
{
|
|
861
|
+
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
862
|
+
return nullptr;
|
|
863
|
+
}
|
|
864
|
+
|
|
872
865
|
auto param0 = py::convert_to<winrt::Windows::Foundation::EventHandler<winrt::Windows::Foundation::IInspectable>>(arg);
|
|
873
866
|
|
|
874
867
|
return py::convert(winrt::Windows::System::Power::PowerManager::RemainingDischargeTimeChanged(param0));
|
|
@@ -882,14 +875,14 @@ namespace py::cpp::Windows::System::Power
|
|
|
882
875
|
|
|
883
876
|
static PyObject* PowerManager_remove_RemainingDischargeTimeChanged(PyObject* /*unused*/, PyObject* arg) noexcept
|
|
884
877
|
{
|
|
885
|
-
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.PowerManager", L"RemainingDischargeTimeChanged"))
|
|
886
|
-
{
|
|
887
|
-
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
888
|
-
return nullptr;
|
|
889
|
-
}
|
|
890
|
-
|
|
891
878
|
try
|
|
892
879
|
{
|
|
880
|
+
if (!winrt::Windows::Foundation::Metadata::ApiInformation::IsEventPresent(L"Windows.System.Power.PowerManager", L"RemainingDischargeTimeChanged"))
|
|
881
|
+
{
|
|
882
|
+
PyErr_SetString(PyExc_AttributeError, "event is not available in this version of Windows");
|
|
883
|
+
return nullptr;
|
|
884
|
+
}
|
|
885
|
+
|
|
893
886
|
auto param0 = py::convert_to<winrt::event_token>(arg);
|
|
894
887
|
|
|
895
888
|
winrt::Windows::System::Power::PowerManager::RemainingDischargeTimeChanged(param0);
|
|
@@ -903,16 +896,6 @@ namespace py::cpp::Windows::System::Power
|
|
|
903
896
|
}
|
|
904
897
|
|
|
905
898
|
static PyMethodDef _methods_PowerManager[] = {
|
|
906
|
-
{ "add_battery_status_changed", reinterpret_cast<PyCFunction>(PowerManager_add_BatteryStatusChanged), METH_O | METH_STATIC, nullptr },
|
|
907
|
-
{ "remove_battery_status_changed", reinterpret_cast<PyCFunction>(PowerManager_remove_BatteryStatusChanged), METH_O | METH_STATIC, nullptr },
|
|
908
|
-
{ "add_energy_saver_status_changed", reinterpret_cast<PyCFunction>(PowerManager_add_EnergySaverStatusChanged), METH_O | METH_STATIC, nullptr },
|
|
909
|
-
{ "remove_energy_saver_status_changed", reinterpret_cast<PyCFunction>(PowerManager_remove_EnergySaverStatusChanged), METH_O | METH_STATIC, nullptr },
|
|
910
|
-
{ "add_power_supply_status_changed", reinterpret_cast<PyCFunction>(PowerManager_add_PowerSupplyStatusChanged), METH_O | METH_STATIC, nullptr },
|
|
911
|
-
{ "remove_power_supply_status_changed", reinterpret_cast<PyCFunction>(PowerManager_remove_PowerSupplyStatusChanged), METH_O | METH_STATIC, nullptr },
|
|
912
|
-
{ "add_remaining_charge_percent_changed", reinterpret_cast<PyCFunction>(PowerManager_add_RemainingChargePercentChanged), METH_O | METH_STATIC, nullptr },
|
|
913
|
-
{ "remove_remaining_charge_percent_changed", reinterpret_cast<PyCFunction>(PowerManager_remove_RemainingChargePercentChanged), METH_O | METH_STATIC, nullptr },
|
|
914
|
-
{ "add_remaining_discharge_time_changed", reinterpret_cast<PyCFunction>(PowerManager_add_RemainingDischargeTimeChanged), METH_O | METH_STATIC, nullptr },
|
|
915
|
-
{ "remove_remaining_discharge_time_changed", reinterpret_cast<PyCFunction>(PowerManager_remove_RemainingDischargeTimeChanged), METH_O | METH_STATIC, nullptr },
|
|
916
899
|
{ }
|
|
917
900
|
};
|
|
918
901
|
|
|
@@ -920,22 +903,19 @@ namespace py::cpp::Windows::System::Power
|
|
|
920
903
|
{ }
|
|
921
904
|
};
|
|
922
905
|
|
|
923
|
-
static PyType_Slot _type_slots_PowerManager[] =
|
|
924
|
-
{
|
|
906
|
+
static PyType_Slot _type_slots_PowerManager[] = {
|
|
925
907
|
{ Py_tp_new, reinterpret_cast<void*>(_new_PowerManager) },
|
|
926
908
|
{ Py_tp_methods, reinterpret_cast<void*>(_methods_PowerManager) },
|
|
927
909
|
{ Py_tp_getset, reinterpret_cast<void*>(_getset_PowerManager) },
|
|
928
|
-
{ }
|
|
910
|
+
{ }
|
|
929
911
|
};
|
|
930
912
|
|
|
931
|
-
static PyType_Spec type_spec_PowerManager =
|
|
932
|
-
{
|
|
913
|
+
static PyType_Spec type_spec_PowerManager = {
|
|
933
914
|
"winrt._winrt_windows_system_power.PowerManager",
|
|
934
915
|
0,
|
|
935
916
|
0,
|
|
936
917
|
Py_TPFLAGS_DEFAULT,
|
|
937
|
-
_type_slots_PowerManager
|
|
938
|
-
};
|
|
918
|
+
_type_slots_PowerManager};
|
|
939
919
|
|
|
940
920
|
static PyGetSetDef getset_PowerManager_Static[] = {
|
|
941
921
|
{ "battery_status", reinterpret_cast<getter>(PowerManager_get_BatteryStatus), nullptr, nullptr, nullptr },
|
|
@@ -947,6 +927,16 @@ namespace py::cpp::Windows::System::Power
|
|
|
947
927
|
};
|
|
948
928
|
|
|
949
929
|
static PyMethodDef methods_PowerManager_Static[] = {
|
|
930
|
+
{ "add_battery_status_changed", reinterpret_cast<PyCFunction>(PowerManager_add_BatteryStatusChanged), METH_O, nullptr },
|
|
931
|
+
{ "remove_battery_status_changed", reinterpret_cast<PyCFunction>(PowerManager_remove_BatteryStatusChanged), METH_O, nullptr },
|
|
932
|
+
{ "add_energy_saver_status_changed", reinterpret_cast<PyCFunction>(PowerManager_add_EnergySaverStatusChanged), METH_O, nullptr },
|
|
933
|
+
{ "remove_energy_saver_status_changed", reinterpret_cast<PyCFunction>(PowerManager_remove_EnergySaverStatusChanged), METH_O, nullptr },
|
|
934
|
+
{ "add_power_supply_status_changed", reinterpret_cast<PyCFunction>(PowerManager_add_PowerSupplyStatusChanged), METH_O, nullptr },
|
|
935
|
+
{ "remove_power_supply_status_changed", reinterpret_cast<PyCFunction>(PowerManager_remove_PowerSupplyStatusChanged), METH_O, nullptr },
|
|
936
|
+
{ "add_remaining_charge_percent_changed", reinterpret_cast<PyCFunction>(PowerManager_add_RemainingChargePercentChanged), METH_O, nullptr },
|
|
937
|
+
{ "remove_remaining_charge_percent_changed", reinterpret_cast<PyCFunction>(PowerManager_remove_RemainingChargePercentChanged), METH_O, nullptr },
|
|
938
|
+
{ "add_remaining_discharge_time_changed", reinterpret_cast<PyCFunction>(PowerManager_add_RemainingDischargeTimeChanged), METH_O, nullptr },
|
|
939
|
+
{ "remove_remaining_discharge_time_changed", reinterpret_cast<PyCFunction>(PowerManager_remove_RemainingDischargeTimeChanged), METH_O, nullptr },
|
|
950
940
|
{ }
|
|
951
941
|
};
|
|
952
942
|
|
|
@@ -968,20 +958,19 @@ namespace py::cpp::Windows::System::Power
|
|
|
968
958
|
};
|
|
969
959
|
|
|
970
960
|
// ----- Windows.System.Power Initialization --------------------
|
|
971
|
-
PyDoc_STRVAR(module_doc, "Windows::System::Power");
|
|
972
|
-
|
|
973
961
|
|
|
974
|
-
|
|
975
|
-
= {PyModuleDef_HEAD_INIT,
|
|
976
|
-
"_winrt_windows_system_power",
|
|
977
|
-
module_doc,
|
|
978
|
-
0,
|
|
979
|
-
nullptr,
|
|
980
|
-
nullptr,
|
|
981
|
-
nullptr,
|
|
982
|
-
nullptr,
|
|
983
|
-
nullptr};
|
|
962
|
+
PyDoc_STRVAR(module_doc, "Windows.System.Power");
|
|
984
963
|
|
|
964
|
+
static PyModuleDef module_def = {
|
|
965
|
+
PyModuleDef_HEAD_INIT,
|
|
966
|
+
"_winrt_windows_system_power",
|
|
967
|
+
module_doc,
|
|
968
|
+
0,
|
|
969
|
+
nullptr,
|
|
970
|
+
nullptr,
|
|
971
|
+
nullptr,
|
|
972
|
+
nullptr,
|
|
973
|
+
nullptr};
|
|
985
974
|
} // py::cpp::Windows::System::Power
|
|
986
975
|
|
|
987
976
|
PyMODINIT_FUNC PyInit__winrt_windows_system_power(void) noexcept
|
|
@@ -0,0 +1 @@
|
|
|
1
|
+
2.1.0
|
|
@@ -1,3 +1,3 @@
|
|
|
1
|
-
# WARNING: Please don't edit this file. It was generated by Python/WinRT v2.0
|
|
1
|
+
# WARNING: Please don't edit this file. It was generated by Python/WinRT v2.1.0
|
|
2
2
|
|
|
3
|
-
winrt-runtime==2.0
|
|
3
|
+
winrt-runtime==2.1.0
|
|
@@ -0,0 +1,94 @@
|
|
|
1
|
+
# WARNING: Please don't edit this file. It was generated by Python/WinRT v2.1.0
|
|
2
|
+
|
|
3
|
+
import datetime
|
|
4
|
+
import sys
|
|
5
|
+
import types
|
|
6
|
+
import typing
|
|
7
|
+
import uuid as _uuid
|
|
8
|
+
from builtins import property as _property
|
|
9
|
+
|
|
10
|
+
import winrt._winrt
|
|
11
|
+
import winrt.system
|
|
12
|
+
import winrt.windows.foundation as windows_foundation
|
|
13
|
+
|
|
14
|
+
from winrt.windows.system.power import BatteryStatus, EnergySaverStatus, PowerSupplyStatus
|
|
15
|
+
|
|
16
|
+
Self = typing.TypeVar('Self')
|
|
17
|
+
|
|
18
|
+
@typing.final
|
|
19
|
+
class BackgroundEnergyManager_Static(type):
|
|
20
|
+
def add_recent_energy_usage_increased(cls, handler: windows_foundation.EventHandler[winrt.system.Object], /) -> windows_foundation.EventRegistrationToken: ...
|
|
21
|
+
def remove_recent_energy_usage_increased(cls, token: windows_foundation.EventRegistrationToken, /) -> None: ...
|
|
22
|
+
def add_recent_energy_usage_returned_to_low(cls, handler: windows_foundation.EventHandler[winrt.system.Object], /) -> windows_foundation.EventRegistrationToken: ...
|
|
23
|
+
def remove_recent_energy_usage_returned_to_low(cls, token: windows_foundation.EventRegistrationToken, /) -> None: ...
|
|
24
|
+
@_property
|
|
25
|
+
def excessive_usage_level(cls) -> winrt.system.UInt32: ...
|
|
26
|
+
@_property
|
|
27
|
+
def low_usage_level(cls) -> winrt.system.UInt32: ...
|
|
28
|
+
@_property
|
|
29
|
+
def max_acceptable_usage_level(cls) -> winrt.system.UInt32: ...
|
|
30
|
+
@_property
|
|
31
|
+
def near_max_acceptable_usage_level(cls) -> winrt.system.UInt32: ...
|
|
32
|
+
@_property
|
|
33
|
+
def near_termination_usage_level(cls) -> winrt.system.UInt32: ...
|
|
34
|
+
@_property
|
|
35
|
+
def recent_energy_usage(cls) -> winrt.system.UInt32: ...
|
|
36
|
+
@_property
|
|
37
|
+
def recent_energy_usage_level(cls) -> winrt.system.UInt32: ...
|
|
38
|
+
@_property
|
|
39
|
+
def termination_usage_level(cls) -> winrt.system.UInt32: ...
|
|
40
|
+
|
|
41
|
+
@typing.final
|
|
42
|
+
class BackgroundEnergyManager(winrt.system.Object, metaclass=BackgroundEnergyManager_Static):
|
|
43
|
+
pass
|
|
44
|
+
|
|
45
|
+
@typing.final
|
|
46
|
+
class ForegroundEnergyManager_Static(type):
|
|
47
|
+
def add_recent_energy_usage_increased(cls, handler: windows_foundation.EventHandler[winrt.system.Object], /) -> windows_foundation.EventRegistrationToken: ...
|
|
48
|
+
def remove_recent_energy_usage_increased(cls, token: windows_foundation.EventRegistrationToken, /) -> None: ...
|
|
49
|
+
def add_recent_energy_usage_returned_to_low(cls, handler: windows_foundation.EventHandler[winrt.system.Object], /) -> windows_foundation.EventRegistrationToken: ...
|
|
50
|
+
def remove_recent_energy_usage_returned_to_low(cls, token: windows_foundation.EventRegistrationToken, /) -> None: ...
|
|
51
|
+
@_property
|
|
52
|
+
def excessive_usage_level(cls) -> winrt.system.UInt32: ...
|
|
53
|
+
@_property
|
|
54
|
+
def low_usage_level(cls) -> winrt.system.UInt32: ...
|
|
55
|
+
@_property
|
|
56
|
+
def max_acceptable_usage_level(cls) -> winrt.system.UInt32: ...
|
|
57
|
+
@_property
|
|
58
|
+
def near_max_acceptable_usage_level(cls) -> winrt.system.UInt32: ...
|
|
59
|
+
@_property
|
|
60
|
+
def recent_energy_usage(cls) -> winrt.system.UInt32: ...
|
|
61
|
+
@_property
|
|
62
|
+
def recent_energy_usage_level(cls) -> winrt.system.UInt32: ...
|
|
63
|
+
|
|
64
|
+
@typing.final
|
|
65
|
+
class ForegroundEnergyManager(winrt.system.Object, metaclass=ForegroundEnergyManager_Static):
|
|
66
|
+
pass
|
|
67
|
+
|
|
68
|
+
@typing.final
|
|
69
|
+
class PowerManager_Static(type):
|
|
70
|
+
def add_battery_status_changed(cls, handler: windows_foundation.EventHandler[winrt.system.Object], /) -> windows_foundation.EventRegistrationToken: ...
|
|
71
|
+
def remove_battery_status_changed(cls, token: windows_foundation.EventRegistrationToken, /) -> None: ...
|
|
72
|
+
def add_energy_saver_status_changed(cls, handler: windows_foundation.EventHandler[winrt.system.Object], /) -> windows_foundation.EventRegistrationToken: ...
|
|
73
|
+
def remove_energy_saver_status_changed(cls, token: windows_foundation.EventRegistrationToken, /) -> None: ...
|
|
74
|
+
def add_power_supply_status_changed(cls, handler: windows_foundation.EventHandler[winrt.system.Object], /) -> windows_foundation.EventRegistrationToken: ...
|
|
75
|
+
def remove_power_supply_status_changed(cls, token: windows_foundation.EventRegistrationToken, /) -> None: ...
|
|
76
|
+
def add_remaining_charge_percent_changed(cls, handler: windows_foundation.EventHandler[winrt.system.Object], /) -> windows_foundation.EventRegistrationToken: ...
|
|
77
|
+
def remove_remaining_charge_percent_changed(cls, token: windows_foundation.EventRegistrationToken, /) -> None: ...
|
|
78
|
+
def add_remaining_discharge_time_changed(cls, handler: windows_foundation.EventHandler[winrt.system.Object], /) -> windows_foundation.EventRegistrationToken: ...
|
|
79
|
+
def remove_remaining_discharge_time_changed(cls, token: windows_foundation.EventRegistrationToken, /) -> None: ...
|
|
80
|
+
@_property
|
|
81
|
+
def battery_status(cls) -> BatteryStatus: ...
|
|
82
|
+
@_property
|
|
83
|
+
def energy_saver_status(cls) -> EnergySaverStatus: ...
|
|
84
|
+
@_property
|
|
85
|
+
def power_supply_status(cls) -> PowerSupplyStatus: ...
|
|
86
|
+
@_property
|
|
87
|
+
def remaining_charge_percent(cls) -> winrt.system.Int32: ...
|
|
88
|
+
@_property
|
|
89
|
+
def remaining_discharge_time(cls) -> datetime.timedelta: ...
|
|
90
|
+
|
|
91
|
+
@typing.final
|
|
92
|
+
class PowerManager(winrt.system.Object, metaclass=PowerManager_Static):
|
|
93
|
+
pass
|
|
94
|
+
|
|
@@ -1,6 +1,6 @@
|
|
|
1
1
|
Metadata-Version: 2.1
|
|
2
2
|
Name: winrt-Windows.System.Power
|
|
3
|
-
Version: 2.0
|
|
3
|
+
Version: 2.1.0
|
|
4
4
|
Summary: Python projection of Windows Runtime (WinRT) APIs
|
|
5
5
|
License: MIT
|
|
6
6
|
Project-URL: Documentation, https://pywinrt.readthedocs.io
|
|
@@ -12,9 +12,9 @@ Classifier: Programming Language :: Python :: Implementation :: CPython
|
|
|
12
12
|
Classifier: Intended Audience :: Developers
|
|
13
13
|
Requires-Python: <3.13,>=3.9
|
|
14
14
|
Description-Content-Type: text/markdown
|
|
15
|
-
Requires-Dist: winrt-runtime==2.0
|
|
15
|
+
Requires-Dist: winrt-runtime==2.1.0
|
|
16
16
|
Provides-Extra: all
|
|
17
|
-
Requires-Dist: winrt-Windows.Foundation[all]==2.0
|
|
17
|
+
Requires-Dist: winrt-Windows.Foundation[all]==2.1.0; extra == "all"
|
|
18
18
|
|
|
19
19
|
<!-- warning: Please don't edit this file. It was automatically generated. -->
|
|
20
20
|
|
|
@@ -1 +0,0 @@
|
|
|
1
|
-
2.0.1
|
|
@@ -1,97 +0,0 @@
|
|
|
1
|
-
# WARNING: Please don't edit this file. It was generated by Python/WinRT v2.0.1
|
|
2
|
-
|
|
3
|
-
import datetime
|
|
4
|
-
import sys
|
|
5
|
-
import types
|
|
6
|
-
import typing
|
|
7
|
-
import uuid as _uuid
|
|
8
|
-
from builtins import property as _property
|
|
9
|
-
|
|
10
|
-
import winrt._winrt
|
|
11
|
-
import winrt.system
|
|
12
|
-
import winrt.windows.foundation
|
|
13
|
-
|
|
14
|
-
from winrt.windows.system.power import BatteryStatus, EnergySaverStatus, PowerSupplyStatus
|
|
15
|
-
|
|
16
|
-
Self = typing.TypeVar('Self')
|
|
17
|
-
|
|
18
|
-
@typing.final
|
|
19
|
-
class BackgroundEnergyManager_Static(type):
|
|
20
|
-
def add_recent_energy_usage_increased(cls, handler: winrt.windows.foundation.EventHandler[winrt.system.Object], /) -> winrt.windows.foundation.EventRegistrationToken: ...
|
|
21
|
-
def remove_recent_energy_usage_increased(cls, token: winrt.windows.foundation.EventRegistrationToken, /) -> None: ...
|
|
22
|
-
def add_recent_energy_usage_returned_to_low(cls, handler: winrt.windows.foundation.EventHandler[winrt.system.Object], /) -> winrt.windows.foundation.EventRegistrationToken: ...
|
|
23
|
-
def remove_recent_energy_usage_returned_to_low(cls, token: winrt.windows.foundation.EventRegistrationToken, /) -> None: ...
|
|
24
|
-
@_property
|
|
25
|
-
def excessive_usage_level(cls) -> winrt.system.UInt32: ...
|
|
26
|
-
@_property
|
|
27
|
-
def low_usage_level(cls) -> winrt.system.UInt32: ...
|
|
28
|
-
@_property
|
|
29
|
-
def max_acceptable_usage_level(cls) -> winrt.system.UInt32: ...
|
|
30
|
-
@_property
|
|
31
|
-
def near_max_acceptable_usage_level(cls) -> winrt.system.UInt32: ...
|
|
32
|
-
@_property
|
|
33
|
-
def near_termination_usage_level(cls) -> winrt.system.UInt32: ...
|
|
34
|
-
@_property
|
|
35
|
-
def recent_energy_usage(cls) -> winrt.system.UInt32: ...
|
|
36
|
-
@_property
|
|
37
|
-
def recent_energy_usage_level(cls) -> winrt.system.UInt32: ...
|
|
38
|
-
@_property
|
|
39
|
-
def termination_usage_level(cls) -> winrt.system.UInt32: ...
|
|
40
|
-
|
|
41
|
-
@typing.final
|
|
42
|
-
class BackgroundEnergyManager(winrt.system.Object, metaclass=BackgroundEnergyManager_Static):
|
|
43
|
-
@staticmethod
|
|
44
|
-
def _from(obj: winrt.system.Object, /) -> BackgroundEnergyManager: ...
|
|
45
|
-
|
|
46
|
-
@typing.final
|
|
47
|
-
class ForegroundEnergyManager_Static(type):
|
|
48
|
-
def add_recent_energy_usage_increased(cls, handler: winrt.windows.foundation.EventHandler[winrt.system.Object], /) -> winrt.windows.foundation.EventRegistrationToken: ...
|
|
49
|
-
def remove_recent_energy_usage_increased(cls, token: winrt.windows.foundation.EventRegistrationToken, /) -> None: ...
|
|
50
|
-
def add_recent_energy_usage_returned_to_low(cls, handler: winrt.windows.foundation.EventHandler[winrt.system.Object], /) -> winrt.windows.foundation.EventRegistrationToken: ...
|
|
51
|
-
def remove_recent_energy_usage_returned_to_low(cls, token: winrt.windows.foundation.EventRegistrationToken, /) -> None: ...
|
|
52
|
-
@_property
|
|
53
|
-
def excessive_usage_level(cls) -> winrt.system.UInt32: ...
|
|
54
|
-
@_property
|
|
55
|
-
def low_usage_level(cls) -> winrt.system.UInt32: ...
|
|
56
|
-
@_property
|
|
57
|
-
def max_acceptable_usage_level(cls) -> winrt.system.UInt32: ...
|
|
58
|
-
@_property
|
|
59
|
-
def near_max_acceptable_usage_level(cls) -> winrt.system.UInt32: ...
|
|
60
|
-
@_property
|
|
61
|
-
def recent_energy_usage(cls) -> winrt.system.UInt32: ...
|
|
62
|
-
@_property
|
|
63
|
-
def recent_energy_usage_level(cls) -> winrt.system.UInt32: ...
|
|
64
|
-
|
|
65
|
-
@typing.final
|
|
66
|
-
class ForegroundEnergyManager(winrt.system.Object, metaclass=ForegroundEnergyManager_Static):
|
|
67
|
-
@staticmethod
|
|
68
|
-
def _from(obj: winrt.system.Object, /) -> ForegroundEnergyManager: ...
|
|
69
|
-
|
|
70
|
-
@typing.final
|
|
71
|
-
class PowerManager_Static(type):
|
|
72
|
-
def add_battery_status_changed(cls, handler: winrt.windows.foundation.EventHandler[winrt.system.Object], /) -> winrt.windows.foundation.EventRegistrationToken: ...
|
|
73
|
-
def remove_battery_status_changed(cls, token: winrt.windows.foundation.EventRegistrationToken, /) -> None: ...
|
|
74
|
-
def add_energy_saver_status_changed(cls, handler: winrt.windows.foundation.EventHandler[winrt.system.Object], /) -> winrt.windows.foundation.EventRegistrationToken: ...
|
|
75
|
-
def remove_energy_saver_status_changed(cls, token: winrt.windows.foundation.EventRegistrationToken, /) -> None: ...
|
|
76
|
-
def add_power_supply_status_changed(cls, handler: winrt.windows.foundation.EventHandler[winrt.system.Object], /) -> winrt.windows.foundation.EventRegistrationToken: ...
|
|
77
|
-
def remove_power_supply_status_changed(cls, token: winrt.windows.foundation.EventRegistrationToken, /) -> None: ...
|
|
78
|
-
def add_remaining_charge_percent_changed(cls, handler: winrt.windows.foundation.EventHandler[winrt.system.Object], /) -> winrt.windows.foundation.EventRegistrationToken: ...
|
|
79
|
-
def remove_remaining_charge_percent_changed(cls, token: winrt.windows.foundation.EventRegistrationToken, /) -> None: ...
|
|
80
|
-
def add_remaining_discharge_time_changed(cls, handler: winrt.windows.foundation.EventHandler[winrt.system.Object], /) -> winrt.windows.foundation.EventRegistrationToken: ...
|
|
81
|
-
def remove_remaining_discharge_time_changed(cls, token: winrt.windows.foundation.EventRegistrationToken, /) -> None: ...
|
|
82
|
-
@_property
|
|
83
|
-
def battery_status(cls) -> BatteryStatus: ...
|
|
84
|
-
@_property
|
|
85
|
-
def energy_saver_status(cls) -> EnergySaverStatus: ...
|
|
86
|
-
@_property
|
|
87
|
-
def power_supply_status(cls) -> PowerSupplyStatus: ...
|
|
88
|
-
@_property
|
|
89
|
-
def remaining_charge_percent(cls) -> winrt.system.Int32: ...
|
|
90
|
-
@_property
|
|
91
|
-
def remaining_discharge_time(cls) -> datetime.timedelta: ...
|
|
92
|
-
|
|
93
|
-
@typing.final
|
|
94
|
-
class PowerManager(winrt.system.Object, metaclass=PowerManager_Static):
|
|
95
|
-
@staticmethod
|
|
96
|
-
def _from(obj: winrt.system.Object, /) -> PowerManager: ...
|
|
97
|
-
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|