width-debias 0.4.0__tar.gz

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
@@ -0,0 +1,21 @@
1
+ MIT License
2
+
3
+ Copyright (c) 2026 Joseph J. Thiebes
4
+
5
+ Permission is hereby granted, free of charge, to any person obtaining a copy
6
+ of this software and associated documentation files (the "Software"), to deal
7
+ in the Software without restriction, including without limitation the rights
8
+ to use, copy, modify, merge, publish, distribute, sublicense, and/or sell
9
+ copies of the Software, and to permit persons to whom the Software is
10
+ furnished to do so, subject to the following conditions:
11
+
12
+ The above copyright notice and this permission notice shall be included in all
13
+ copies or substantial portions of the Software.
14
+
15
+ THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR
16
+ IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY,
17
+ FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE
18
+ AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER
19
+ LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM,
20
+ OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE
21
+ SOFTWARE.
@@ -0,0 +1,239 @@
1
+ Metadata-Version: 2.4
2
+ Name: width-debias
3
+ Version: 0.4.0
4
+ Summary: Correction of the noise bias in fitted profile widths, for mean-squared-displacement (MSD) diffusion measurements.
5
+ Author-email: "Joseph J. Thiebes" <joseph@thiebes.org>
6
+ License-Expression: MIT
7
+ Project-URL: Source, https://github.com/thiebes/width-debias
8
+ Project-URL: Changelog, https://github.com/thiebes/width-debias/blob/master/CHANGELOG.md
9
+ Project-URL: Issues, https://github.com/thiebes/width-debias/issues
10
+ Keywords: diffusion,mean-squared displacement,bias correction,contrast-to-noise ratio,transient microscopy
11
+ Classifier: Development Status :: 3 - Alpha
12
+ Classifier: Intended Audience :: Science/Research
13
+ Classifier: Operating System :: OS Independent
14
+ Classifier: Programming Language :: Python :: 3
15
+ Classifier: Programming Language :: Python :: 3.11
16
+ Classifier: Programming Language :: Python :: 3.12
17
+ Classifier: Programming Language :: Python :: 3.13
18
+ Classifier: Topic :: Scientific/Engineering :: Physics
19
+ Requires-Python: >=3.11
20
+ Description-Content-Type: text/markdown
21
+ License-File: LICENSE
22
+ Requires-Dist: numpy<3,>=1.24
23
+ Requires-Dist: scipy<2,>=1.10
24
+ Provides-Extra: cnr
25
+ Requires-Dist: fft-cnr<0.5,>=0.3.3; extra == "cnr"
26
+ Provides-Extra: plot
27
+ Requires-Dist: matplotlib<4,>=3.7; extra == "plot"
28
+ Requires-Dist: curved-text<1,>=0.5; extra == "plot"
29
+ Provides-Extra: dev
30
+ Requires-Dist: pytest>=7.4; extra == "dev"
31
+ Requires-Dist: matplotlib<4,>=3.7; extra == "dev"
32
+ Requires-Dist: fft-cnr<0.5,>=0.3.3; extra == "dev"
33
+ Requires-Dist: curved-text<1,>=0.5; extra == "dev"
34
+ Dynamic: license-file
35
+
36
+ # width-debias
37
+
38
+ **Correction of the noise bias in fitted profile widths, for
39
+ mean-squared-displacement (MSD) diffusion measurements.**
40
+
41
+ A width fitted to a noisy profile scatters about the true width, and squaring
42
+ it to form the variance turns that scatter into a bias. On average the fitted
43
+ variance exceeds the true one by the width's estimation variance,
44
+ `E[sigma_hat^2] = sigma^2 + Var(sigma_hat)`. To leading order Var(sigma_hat) is
45
+ the Cramér-Rao value, which for a Gaussian profile at a fixed pixel spacing `dx`
46
+ is `(2/sqrt(pi)) sigma dx / CNR^2`, so the bias grows as the contrast-to-noise
47
+ ratio (CNR) falls. In a transient measurement the CNR falls frame by frame as
48
+ the population decays, so the bias rises over time, tilts the MSD curve upward,
49
+ and inflates the diffusion coefficient D. In simulation (Gaussian profile,
50
+ D = 0.02 sigma_0^2/tau, initial CNR 34) an unweighted fit returns 1.20 times the
51
+ reference D. Inverse-variance weighting corrects the unequal noise across
52
+ frames but cannot remove a mean bias present in every point.
53
+
54
+ The package corrects each profile's fitted width, and the MSD and D follow. It
55
+ subtracts a Monte Carlo calibrated bias `var_bias(CNR)` from each frame's fitted
56
+ variance before the slope fit, keyed on the per-frame CNR; in the same
57
+ simulation the corrected fit returns 1.00 times the reference. The calibration
58
+ is built at D = 0, so it does not require a prior value of D. Removing the
59
+ fit's lower bound on the width does not help: above a per-frame CNR of about
60
+ 1.5 the bounded and unbounded fits are identical, and both carry the full bias.
61
+ Below a per-frame CNR of about 1 the fits spread into a broad upper tail and the
62
+ correction no longer holds (see [On real data](#on-real-data)). The derivation,
63
+ which reaches the same additive form from a folded-normal model of the width
64
+ estimate, is in
65
+ [`docs/DERIVATION.md`](https://github.com/thiebes/width-debias/blob/v0.4.0/docs/DERIVATION.md).
66
+
67
+ ## Install
68
+
69
+ ```bash
70
+ pip install width-debias # core: NumPy and SciPy
71
+ pip install "width-debias[cnr]" # adds fft-cnr, for per-frame CNR from measured profiles
72
+ ```
73
+
74
+ To run the experiments and tests, install from a clone of the
75
+ [repository](https://github.com/thiebes/width-debias):
76
+
77
+ ```bash
78
+ python -m venv .venv
79
+ .venv/Scripts/activate # Windows; source .venv/bin/activate elsewhere
80
+ pip install -e .[dev] # core + matplotlib + pytest + fft-cnr
81
+ ```
82
+
83
+ `uv.lock` in the repository records the exact environment that produced the
84
+ committed results.
85
+
86
+ ## Quick start
87
+
88
+ ```python
89
+ import numpy as np
90
+ from width_debias import Experiment, calibrate_d_free, evaluate
91
+
92
+ cnr0 = np.array([5, 8, 13, 21, 34, 55, 90])
93
+ lookup = calibrate_d_free(cnr0, n_runs=300) # D-free lookup var_bias(CNR)
94
+
95
+ exp = Experiment(D=0.02) # sigma_0^2/tau; L_D/FWHM_0 ~ 0.085
96
+ results = evaluate(exp, cnr0, lookup, n_runs=300)
97
+
98
+ r = results["subtract"]
99
+ se = np.hypot(r.spread / np.sqrt(300), r.cal_se) # evaluation + calibration SE
100
+ print(r.mean_bias, se) # <D_est>/D_ref per CNR_0
101
+ ```
102
+
103
+ On a measurement, the per-frame CNR comes from `width_debias.cnr.per_frame_cnr`
104
+ (which wraps `fft-cnr`), the corrected MSD and weights from
105
+ `width_debias.weights.msd_and_weights("subtract", ...)`, the slope from
106
+ `width_debias.fit.fit_D`, and the calibration's contribution to the
107
+ uncertainty from `width_debias.weights.calibration_D_se`:
108
+
109
+ ```python
110
+ import numpy as np
111
+ from width_debias import calibrate_d_free
112
+ from width_debias.cnr import per_frame_cnr
113
+ from width_debias.fit import fit_D
114
+ from width_debias.weights import calibration_D_se, msd_and_weights
115
+
116
+ # times (n_frames,); profiles (n_frames, n_pixels) cut to about +/-4 sigma_0
117
+ # around the spot; variance (n_frames,) the fitted widths in px^2;
118
+ # sigma0_px the t = 0 width in pixels
119
+ n_pixels = profiles.shape[1]
120
+ lookup = calibrate_d_free(cnr0, half_window=(n_pixels / 2) / sigma0_px,
121
+ n_pixels=n_pixels) # the data's grid, in units of sigma_0
122
+ cnr = per_frame_cnr(profiles)
123
+ msd, w = msd_and_weights("subtract", variance / sigma0_px**2, cnr, lookup)
124
+ w = np.where(cnr >= 1.3, w, 0.0) # drop frames below the floor
125
+ fit = fit_D(times, msd, w)
126
+ D = fit.D * sigma0_px**2 # px^2 per unit time
127
+ se = np.hypot(fit.D_se, calibration_D_se(times, msd, w, cnr, lookup)) * sigma0_px**2
128
+ ```
129
+
130
+ ## On real data
131
+
132
+ The validation keys the lookup on the exact per-frame CNR, uses a calibration
133
+ built for the same geometry as the data, and drops frames below the floor. On a
134
+ measurement each of these is a step for the user; the library does not check
135
+ them.
136
+
137
+ - **Match the calibration to the data.** `var_bias` is a variance in the length
138
+ unit of the calibration, and its size depends on the pixel grid, the profile
139
+ model and its fit bound, and the noise law. Work in units of the measured
140
+ t = 0 width sigma_0: divide the pixel axis by sigma_0 and the fitted
141
+ variances by sigma_0^2, build the calibration with the data's pixel count and
142
+ half-window in those units
143
+ (`calibrate_d_free(cnr0, half_window=(n_pixels / 2) / sigma0_px, n_pixels=n_pixels, model=..., noise_model=...)`),
144
+ and multiply the fitted D and its SE by sigma_0^2 at the end. A calibration in
145
+ units of sigma_0 applied to widths in micrometres subtracts a bias that is
146
+ off by the square of the unit ratio (16 for sigma_0 = 0.25 μm).
147
+ - **Drop frames below the floor.** The correction holds above a per-frame CNR
148
+ of about 1 (0.7 to 1.5 depending on shape). `msd_and_weights` applies no
149
+ floor, and a CNR outside the calibrated grid takes the value at the nearest
150
+ grid edge. The validations set the weight of frames below a per-frame CNR of
151
+ 1.0 or 1.3 to zero before `fit_D`, as in the example above.
152
+ - **The estimated CNR holds over a narrower range.** With the CNR estimated
153
+ from each frame by `fft-cnr` instead of known, the corrected mean D holds in
154
+ simulation only where every fitted frame stays well above the floor: from an
155
+ initial CNR of about 34 at D = 0.02 sigma_0^2/tau for the Gaussian profile
156
+ (about 55 for p = 1.5 and 13 for p = 4), and from about 21 at D >= 0.05.
157
+ Below that, the pooled Gaussian mean at D = 0.02 over initial CNR 8 to 90 is
158
+ 1.9 of the reference (standard error 0.4). See
159
+ [`experiments/wse2-strobescat`](https://github.com/thiebes/width-debias/tree/v0.4.0/experiments/wse2-strobescat).
160
+ - **Estimate the CNR on the spot.** Cut each profile to about ±4 sigma_0 around
161
+ the spot before calling `per_frame_cnr`. Background and fringe structure in a
162
+ full line cut corrupts the spectral CNR estimate at low signal.
163
+
164
+ ## What the validation shows
165
+
166
+ - Above a per-frame CNR of about 1.5 the fit's lower bound does not bind: the
167
+ bounded and unbounded fits return the same widths and the same biased D
168
+ (`experiments/estimator-comparison`). Below it, the bounded fit reflects
169
+ rather than clips at the bound (`experiments/boundary-diagnostic`).
170
+ - With the calibration's own Monte Carlo error included, 4 of 96 cells lie
171
+ beyond two combined standard errors of the reference (Gaussian, Voigt, and
172
+ generalized-Gaussian p = 1.5 and p = 4 profiles; D = 0.005, 0.02, and 0.1
173
+ sigma_0^2/tau; initial CNR 3 to 90; `slope_fit_check.txt`). The cells share
174
+ noise seeds across shapes and one calibration per shape, so the count is
175
+ indicative rather than a test against a binomial null. At small D and low
176
+ initial CNR the combined SE is large, so those cells constrain the bias only
177
+ loosely (`experiments/dfree-calibration`).
178
+ - The correction holds above a per-frame CNR of about 1 (0.7 to 1.5 depending on
179
+ shape), where the leading-order bias model `var_bias = A / CNR^2` itself
180
+ breaks (`experiments/correction-floor`). With single-exponential decay to
181
+ 3 tau, every frame stays above the floor from an initial CNR of about 20.
182
+ - It corrects the anomalous exponent of subdiffusive transport as well as D
183
+ (`experiments/subdiffusive-alpha`, `experiments/nc-solid`).
184
+
185
+ [`docs/REPO_MAP.md`](https://github.com/thiebes/width-debias/blob/v0.4.0/docs/REPO_MAP.md)
186
+ lists every experiment set with its result, and each set's README gives the
187
+ details and how to run it.
188
+
189
+ ## Profile models
190
+
191
+ The bias affects any non-negative width estimator, so the profile model is
192
+ pluggable (`width_debias.models`): `GaussianModel`, `VoigtModel` (a diffusing
193
+ Gaussian convolved with a fixed Lorentzian point-spread function), and
194
+ `GeneralizedGaussianModel` (shape exponent p; p = 2 is the Gaussian).
195
+ `model_from_spec("generalized_gaussian:1.5")` builds a model from a spec
196
+ string. The experiment scripts in the repository take a model spec; name the
197
+ generalized-Gaussian shape explicitly:
198
+
199
+ ```bash
200
+ python experiments/poc-bias-correction/poc_demo.py voigt
201
+ python experiments/boundary-diagnostic/diagnose_boundary.py generalized_gaussian:1.5
202
+ ```
203
+
204
+ ## Tests
205
+
206
+ ```bash
207
+ pytest
208
+ ```
209
+
210
+ ## Layout
211
+
212
+ | Path | Role |
213
+ | ------- | ------- |
214
+ | `src/width_debias/simulate.py` | profile geometry: diffusion, decay, noise |
215
+ | `src/width_debias/noise.py` | noise laws: white, shot, Poisson, read floor |
216
+ | `src/width_debias/models.py` | profile models and `model_from_spec` |
217
+ | `src/width_debias/fit.py` | per-frame width fit; MSD to D linear fit |
218
+ | `src/width_debias/montecarlo.py` | Monte Carlo ensembles |
219
+ | `src/width_debias/bias_lookup.py` | per-frame statistics; `BiasLookup` lookups and their SE |
220
+ | `src/width_debias/calibration.py` | single-frame calibration cells; joint (CNR, sigma^2) calibration |
221
+ | `src/width_debias/fisher.py` | Fisher-information width variance, leading-order bias, CRLB on D |
222
+ | `src/width_debias/smoothing.py` | P-spline smoother for the calibration residual |
223
+ | `src/width_debias/weights.py` | the four schemes; calibration SE of D |
224
+ | `src/width_debias/validate.py` | calibration and evaluation sweeps |
225
+ | `src/width_debias/cnr.py` | per-frame CNR from measured profiles via `fft-cnr` |
226
+ | `experiments/` | one folder per experiment set (see `docs/REPO_MAP.md`) |
227
+ | `illustrations/` | schematic figures |
228
+ | `scripts/` | shared calibration tooling and figure rendering |
229
+
230
+ ## Related work
231
+
232
+ - **DICE**: Monte Carlo engine for optical diffusion measurements (Thiebes and
233
+ Grumstrup, *J. Chem. Phys.* 2024).
234
+ - **fft-cnr**: single-profile CNR estimation
235
+ ([PyPI](https://pypi.org/project/fft-cnr/)).
236
+
237
+ ## License
238
+
239
+ MIT, see [`LICENSE`](https://github.com/thiebes/width-debias/blob/v0.4.0/LICENSE).
@@ -0,0 +1,204 @@
1
+ # width-debias
2
+
3
+ **Correction of the noise bias in fitted profile widths, for
4
+ mean-squared-displacement (MSD) diffusion measurements.**
5
+
6
+ A width fitted to a noisy profile scatters about the true width, and squaring
7
+ it to form the variance turns that scatter into a bias. On average the fitted
8
+ variance exceeds the true one by the width's estimation variance,
9
+ `E[sigma_hat^2] = sigma^2 + Var(sigma_hat)`. To leading order Var(sigma_hat) is
10
+ the Cramér-Rao value, which for a Gaussian profile at a fixed pixel spacing `dx`
11
+ is `(2/sqrt(pi)) sigma dx / CNR^2`, so the bias grows as the contrast-to-noise
12
+ ratio (CNR) falls. In a transient measurement the CNR falls frame by frame as
13
+ the population decays, so the bias rises over time, tilts the MSD curve upward,
14
+ and inflates the diffusion coefficient D. In simulation (Gaussian profile,
15
+ D = 0.02 sigma_0^2/tau, initial CNR 34) an unweighted fit returns 1.20 times the
16
+ reference D. Inverse-variance weighting corrects the unequal noise across
17
+ frames but cannot remove a mean bias present in every point.
18
+
19
+ The package corrects each profile's fitted width, and the MSD and D follow. It
20
+ subtracts a Monte Carlo calibrated bias `var_bias(CNR)` from each frame's fitted
21
+ variance before the slope fit, keyed on the per-frame CNR; in the same
22
+ simulation the corrected fit returns 1.00 times the reference. The calibration
23
+ is built at D = 0, so it does not require a prior value of D. Removing the
24
+ fit's lower bound on the width does not help: above a per-frame CNR of about
25
+ 1.5 the bounded and unbounded fits are identical, and both carry the full bias.
26
+ Below a per-frame CNR of about 1 the fits spread into a broad upper tail and the
27
+ correction no longer holds (see [On real data](#on-real-data)). The derivation,
28
+ which reaches the same additive form from a folded-normal model of the width
29
+ estimate, is in
30
+ [`docs/DERIVATION.md`](https://github.com/thiebes/width-debias/blob/v0.4.0/docs/DERIVATION.md).
31
+
32
+ ## Install
33
+
34
+ ```bash
35
+ pip install width-debias # core: NumPy and SciPy
36
+ pip install "width-debias[cnr]" # adds fft-cnr, for per-frame CNR from measured profiles
37
+ ```
38
+
39
+ To run the experiments and tests, install from a clone of the
40
+ [repository](https://github.com/thiebes/width-debias):
41
+
42
+ ```bash
43
+ python -m venv .venv
44
+ .venv/Scripts/activate # Windows; source .venv/bin/activate elsewhere
45
+ pip install -e .[dev] # core + matplotlib + pytest + fft-cnr
46
+ ```
47
+
48
+ `uv.lock` in the repository records the exact environment that produced the
49
+ committed results.
50
+
51
+ ## Quick start
52
+
53
+ ```python
54
+ import numpy as np
55
+ from width_debias import Experiment, calibrate_d_free, evaluate
56
+
57
+ cnr0 = np.array([5, 8, 13, 21, 34, 55, 90])
58
+ lookup = calibrate_d_free(cnr0, n_runs=300) # D-free lookup var_bias(CNR)
59
+
60
+ exp = Experiment(D=0.02) # sigma_0^2/tau; L_D/FWHM_0 ~ 0.085
61
+ results = evaluate(exp, cnr0, lookup, n_runs=300)
62
+
63
+ r = results["subtract"]
64
+ se = np.hypot(r.spread / np.sqrt(300), r.cal_se) # evaluation + calibration SE
65
+ print(r.mean_bias, se) # <D_est>/D_ref per CNR_0
66
+ ```
67
+
68
+ On a measurement, the per-frame CNR comes from `width_debias.cnr.per_frame_cnr`
69
+ (which wraps `fft-cnr`), the corrected MSD and weights from
70
+ `width_debias.weights.msd_and_weights("subtract", ...)`, the slope from
71
+ `width_debias.fit.fit_D`, and the calibration's contribution to the
72
+ uncertainty from `width_debias.weights.calibration_D_se`:
73
+
74
+ ```python
75
+ import numpy as np
76
+ from width_debias import calibrate_d_free
77
+ from width_debias.cnr import per_frame_cnr
78
+ from width_debias.fit import fit_D
79
+ from width_debias.weights import calibration_D_se, msd_and_weights
80
+
81
+ # times (n_frames,); profiles (n_frames, n_pixels) cut to about +/-4 sigma_0
82
+ # around the spot; variance (n_frames,) the fitted widths in px^2;
83
+ # sigma0_px the t = 0 width in pixels
84
+ n_pixels = profiles.shape[1]
85
+ lookup = calibrate_d_free(cnr0, half_window=(n_pixels / 2) / sigma0_px,
86
+ n_pixels=n_pixels) # the data's grid, in units of sigma_0
87
+ cnr = per_frame_cnr(profiles)
88
+ msd, w = msd_and_weights("subtract", variance / sigma0_px**2, cnr, lookup)
89
+ w = np.where(cnr >= 1.3, w, 0.0) # drop frames below the floor
90
+ fit = fit_D(times, msd, w)
91
+ D = fit.D * sigma0_px**2 # px^2 per unit time
92
+ se = np.hypot(fit.D_se, calibration_D_se(times, msd, w, cnr, lookup)) * sigma0_px**2
93
+ ```
94
+
95
+ ## On real data
96
+
97
+ The validation keys the lookup on the exact per-frame CNR, uses a calibration
98
+ built for the same geometry as the data, and drops frames below the floor. On a
99
+ measurement each of these is a step for the user; the library does not check
100
+ them.
101
+
102
+ - **Match the calibration to the data.** `var_bias` is a variance in the length
103
+ unit of the calibration, and its size depends on the pixel grid, the profile
104
+ model and its fit bound, and the noise law. Work in units of the measured
105
+ t = 0 width sigma_0: divide the pixel axis by sigma_0 and the fitted
106
+ variances by sigma_0^2, build the calibration with the data's pixel count and
107
+ half-window in those units
108
+ (`calibrate_d_free(cnr0, half_window=(n_pixels / 2) / sigma0_px, n_pixels=n_pixels, model=..., noise_model=...)`),
109
+ and multiply the fitted D and its SE by sigma_0^2 at the end. A calibration in
110
+ units of sigma_0 applied to widths in micrometres subtracts a bias that is
111
+ off by the square of the unit ratio (16 for sigma_0 = 0.25 μm).
112
+ - **Drop frames below the floor.** The correction holds above a per-frame CNR
113
+ of about 1 (0.7 to 1.5 depending on shape). `msd_and_weights` applies no
114
+ floor, and a CNR outside the calibrated grid takes the value at the nearest
115
+ grid edge. The validations set the weight of frames below a per-frame CNR of
116
+ 1.0 or 1.3 to zero before `fit_D`, as in the example above.
117
+ - **The estimated CNR holds over a narrower range.** With the CNR estimated
118
+ from each frame by `fft-cnr` instead of known, the corrected mean D holds in
119
+ simulation only where every fitted frame stays well above the floor: from an
120
+ initial CNR of about 34 at D = 0.02 sigma_0^2/tau for the Gaussian profile
121
+ (about 55 for p = 1.5 and 13 for p = 4), and from about 21 at D >= 0.05.
122
+ Below that, the pooled Gaussian mean at D = 0.02 over initial CNR 8 to 90 is
123
+ 1.9 of the reference (standard error 0.4). See
124
+ [`experiments/wse2-strobescat`](https://github.com/thiebes/width-debias/tree/v0.4.0/experiments/wse2-strobescat).
125
+ - **Estimate the CNR on the spot.** Cut each profile to about ±4 sigma_0 around
126
+ the spot before calling `per_frame_cnr`. Background and fringe structure in a
127
+ full line cut corrupts the spectral CNR estimate at low signal.
128
+
129
+ ## What the validation shows
130
+
131
+ - Above a per-frame CNR of about 1.5 the fit's lower bound does not bind: the
132
+ bounded and unbounded fits return the same widths and the same biased D
133
+ (`experiments/estimator-comparison`). Below it, the bounded fit reflects
134
+ rather than clips at the bound (`experiments/boundary-diagnostic`).
135
+ - With the calibration's own Monte Carlo error included, 4 of 96 cells lie
136
+ beyond two combined standard errors of the reference (Gaussian, Voigt, and
137
+ generalized-Gaussian p = 1.5 and p = 4 profiles; D = 0.005, 0.02, and 0.1
138
+ sigma_0^2/tau; initial CNR 3 to 90; `slope_fit_check.txt`). The cells share
139
+ noise seeds across shapes and one calibration per shape, so the count is
140
+ indicative rather than a test against a binomial null. At small D and low
141
+ initial CNR the combined SE is large, so those cells constrain the bias only
142
+ loosely (`experiments/dfree-calibration`).
143
+ - The correction holds above a per-frame CNR of about 1 (0.7 to 1.5 depending on
144
+ shape), where the leading-order bias model `var_bias = A / CNR^2` itself
145
+ breaks (`experiments/correction-floor`). With single-exponential decay to
146
+ 3 tau, every frame stays above the floor from an initial CNR of about 20.
147
+ - It corrects the anomalous exponent of subdiffusive transport as well as D
148
+ (`experiments/subdiffusive-alpha`, `experiments/nc-solid`).
149
+
150
+ [`docs/REPO_MAP.md`](https://github.com/thiebes/width-debias/blob/v0.4.0/docs/REPO_MAP.md)
151
+ lists every experiment set with its result, and each set's README gives the
152
+ details and how to run it.
153
+
154
+ ## Profile models
155
+
156
+ The bias affects any non-negative width estimator, so the profile model is
157
+ pluggable (`width_debias.models`): `GaussianModel`, `VoigtModel` (a diffusing
158
+ Gaussian convolved with a fixed Lorentzian point-spread function), and
159
+ `GeneralizedGaussianModel` (shape exponent p; p = 2 is the Gaussian).
160
+ `model_from_spec("generalized_gaussian:1.5")` builds a model from a spec
161
+ string. The experiment scripts in the repository take a model spec; name the
162
+ generalized-Gaussian shape explicitly:
163
+
164
+ ```bash
165
+ python experiments/poc-bias-correction/poc_demo.py voigt
166
+ python experiments/boundary-diagnostic/diagnose_boundary.py generalized_gaussian:1.5
167
+ ```
168
+
169
+ ## Tests
170
+
171
+ ```bash
172
+ pytest
173
+ ```
174
+
175
+ ## Layout
176
+
177
+ | Path | Role |
178
+ | ------- | ------- |
179
+ | `src/width_debias/simulate.py` | profile geometry: diffusion, decay, noise |
180
+ | `src/width_debias/noise.py` | noise laws: white, shot, Poisson, read floor |
181
+ | `src/width_debias/models.py` | profile models and `model_from_spec` |
182
+ | `src/width_debias/fit.py` | per-frame width fit; MSD to D linear fit |
183
+ | `src/width_debias/montecarlo.py` | Monte Carlo ensembles |
184
+ | `src/width_debias/bias_lookup.py` | per-frame statistics; `BiasLookup` lookups and their SE |
185
+ | `src/width_debias/calibration.py` | single-frame calibration cells; joint (CNR, sigma^2) calibration |
186
+ | `src/width_debias/fisher.py` | Fisher-information width variance, leading-order bias, CRLB on D |
187
+ | `src/width_debias/smoothing.py` | P-spline smoother for the calibration residual |
188
+ | `src/width_debias/weights.py` | the four schemes; calibration SE of D |
189
+ | `src/width_debias/validate.py` | calibration and evaluation sweeps |
190
+ | `src/width_debias/cnr.py` | per-frame CNR from measured profiles via `fft-cnr` |
191
+ | `experiments/` | one folder per experiment set (see `docs/REPO_MAP.md`) |
192
+ | `illustrations/` | schematic figures |
193
+ | `scripts/` | shared calibration tooling and figure rendering |
194
+
195
+ ## Related work
196
+
197
+ - **DICE**: Monte Carlo engine for optical diffusion measurements (Thiebes and
198
+ Grumstrup, *J. Chem. Phys.* 2024).
199
+ - **fft-cnr**: single-profile CNR estimation
200
+ ([PyPI](https://pypi.org/project/fft-cnr/)).
201
+
202
+ ## License
203
+
204
+ MIT, see [`LICENSE`](https://github.com/thiebes/width-debias/blob/v0.4.0/LICENSE).
@@ -0,0 +1,70 @@
1
+ [build-system]
2
+ requires = ["setuptools==84.0.0"]
3
+ build-backend = "setuptools.build_meta"
4
+
5
+ [project]
6
+ name = "width-debias"
7
+ # The version lives in one place, width_debias.__version__.
8
+ dynamic = ["version"]
9
+ description = "Correction of the noise bias in fitted profile widths, for mean-squared-displacement (MSD) diffusion measurements."
10
+ readme = "README.md"
11
+ requires-python = ">=3.11"
12
+ license = "MIT"
13
+ license-files = ["LICENSE"]
14
+ authors = [
15
+ { name = "Joseph J. Thiebes", email = "joseph@thiebes.org" },
16
+ ]
17
+ keywords = ["diffusion", "mean-squared displacement", "bias correction",
18
+ "contrast-to-noise ratio", "transient microscopy"]
19
+ classifiers = [
20
+ "Development Status :: 3 - Alpha",
21
+ "Intended Audience :: Science/Research",
22
+ "Operating System :: OS Independent",
23
+ "Programming Language :: Python :: 3",
24
+ "Programming Language :: Python :: 3.11",
25
+ "Programming Language :: Python :: 3.12",
26
+ "Programming Language :: Python :: 3.13",
27
+ "Topic :: Scientific/Engineering :: Physics",
28
+ ]
29
+ # A library's metadata carries compatible ranges; the exact, hashed versions
30
+ # that produced the committed results are in uv.lock.
31
+ dependencies = [
32
+ "numpy>=1.24,<3",
33
+ "scipy>=1.10,<2",
34
+ ]
35
+
36
+ [project.urls]
37
+ Source = "https://github.com/thiebes/width-debias"
38
+ Changelog = "https://github.com/thiebes/width-debias/blob/master/CHANGELOG.md"
39
+ Issues = "https://github.com/thiebes/width-debias/issues"
40
+
41
+ [project.optional-dependencies]
42
+ # fft-cnr supplies per-frame CNR estimates from single 1-D profiles.
43
+ # Used for real experimental data; the Monte Carlo validation knows true CNR.
44
+ # The real-data pipeline needs fft-cnr's refusal of degenerate
45
+ # generalized-Gaussian fits (commit 69cd361); 0.3.3 is the first PyPI release
46
+ # that carries it.
47
+ cnr = ["fft-cnr>=0.3.3,<0.5"]
48
+ # curved-text draws the curved data-series label on the poster figure.
49
+ plot = ["matplotlib>=3.7,<4", "curved-text>=0.5,<1"]
50
+ dev = ["pytest>=7.4", "matplotlib>=3.7,<4", "fft-cnr>=0.3.3,<0.5",
51
+ "curved-text>=0.5,<1"]
52
+
53
+ [tool.setuptools.dynamic]
54
+ version = { attr = "width_debias.__version__" }
55
+
56
+ [tool.setuptools.packages.find]
57
+ where = ["src"]
58
+
59
+ [tool.uv]
60
+ # Lock-only constraints: the environment that produced the committed results
61
+ # and poster figures. They do not enter the published metadata.
62
+ constraint-dependencies = [
63
+ "numpy==2.4.5",
64
+ "scipy==1.17.1",
65
+ "matplotlib==3.10.9",
66
+ "curved-text==0.5.0",
67
+ ]
68
+
69
+ [tool.pytest.ini_options]
70
+ testpaths = ["tests"]
@@ -0,0 +1,4 @@
1
+ [egg_info]
2
+ tag_build =
3
+ tag_date = 0
4
+
@@ -0,0 +1,73 @@
1
+ """width-debias: correcting the noise bias in fitted profile widths.
2
+
3
+ A width fitted to a noisy profile scatters about the true width, so the fitted
4
+ variance exceeds the true one on average by the width's estimation variance,
5
+ which grows as the per-frame CNR falls. In a diffusion measurement the CNR
6
+ falls frame by frame, so the bias rises over time, leaks through the MSD fit,
7
+ and inflates the extracted diffusion coefficient D. Standard inverse-variance
8
+ weighting corrects the unequal noise across frames but cannot remove a mean
9
+ bias from a slope fit.
10
+
11
+ The package subtracts a calibrated bias ``var_bias(CNR)`` from each frame's
12
+ fitted variance, then weights by inverse variance; the MSD and D corrections
13
+ follow from the corrected widths. ``docs/DERIVATION.md`` derives the additive
14
+ form from a folded-normal model of the fitted width. The per-frame CNR (from
15
+ the ``fft-cnr`` package) is the input.
16
+
17
+ Typical use::
18
+
19
+ import numpy as np
20
+ from width_debias import Experiment, calibrate_d_free, evaluate
21
+ from width_debias.fit import fit_D
22
+ from width_debias.weights import msd_and_weights
23
+
24
+ cnr0 = np.array([5, 8, 13, 21, 34, 55, 90])
25
+ lookup = calibrate_d_free(cnr0) # D-free lookup var_bias(CNR)
26
+
27
+ # Monte Carlo bias curves <D_est>/D_ref for ols, inverse_variance,
28
+ # subtract, and mas
29
+ results = evaluate(Experiment(D=0.02), cnr0, lookup)
30
+
31
+ # A measurement: fitted widths in units of sigma_0^2 and per-frame CNR
32
+ msd, w = msd_and_weights("subtract", variance, cnr, lookup)
33
+ w = np.where(cnr >= 1.3, w, 0.0) # drop frames below the floor
34
+ D = fit_D(times, msd, w).D
35
+
36
+ ``subtract`` is the recommended scheme and :func:`calibrate_d_free` the
37
+ recommended calibration. The README states the conditions for real data: a
38
+ calibration that matches the data's geometry and units, and the per-frame CNR
39
+ floor.
40
+ """
41
+ from .simulate import (AnomalousExperiment, Experiment, MultiExpExperiment,
42
+ cnr_per_frame, noisy_series)
43
+ from .models import (GaussianModel, GeneralizedGaussianModel, MODELS,
44
+ MomentModel, UnboundedGaussianModel, VoigtModel,
45
+ model_from_spec, spec_tag)
46
+ from .montecarlo import Ensemble, run_ensemble
47
+ from .bias_lookup import FrameStats, BiasLookup, frame_stats
48
+ from .weights import (SCHEMES, calibration_D_se, corrected_variance,
49
+ msd_and_weights)
50
+ from .validate import (FrameDiagnostic, SchemeResult, calibrate,
51
+ calibrate_d_free, calibrate_fisher, evaluate,
52
+ per_frame_diagnostic, sweep_stats)
53
+ from .calibration import (CalibrationCells, CalibrationGrid, calibrate_cells,
54
+ calibrate_cnr_sigma2)
55
+ from .fisher import LeadingOrderTerms, leading_order_terms
56
+
57
+ __version__ = "0.4.0"
58
+
59
+ __all__ = [
60
+ "Experiment", "AnomalousExperiment", "MultiExpExperiment",
61
+ "cnr_per_frame", "noisy_series",
62
+ "GaussianModel", "VoigtModel", "GeneralizedGaussianModel", "MomentModel",
63
+ "UnboundedGaussianModel", "MODELS", "model_from_spec", "spec_tag",
64
+ "Ensemble", "run_ensemble",
65
+ "FrameStats", "BiasLookup", "frame_stats",
66
+ "SCHEMES", "msd_and_weights", "corrected_variance", "calibration_D_se",
67
+ "SchemeResult", "calibrate", "calibrate_d_free", "calibrate_fisher",
68
+ "evaluate", "sweep_stats",
69
+ "FrameDiagnostic", "per_frame_diagnostic",
70
+ "CalibrationGrid", "calibrate_cnr_sigma2",
71
+ "CalibrationCells", "calibrate_cells",
72
+ "LeadingOrderTerms", "leading_order_terms",
73
+ ]