rainbow-api 1.5.4__tar.gz → 1.5.5__tar.gz
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/CHANGELOG.md +133 -0
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/PKG-INFO +1 -1
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/pyproject.toml +1 -1
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow/__init__.py +39 -11
- rainbow_api-1.5.5/rainbow/_optics.py +33 -0
- rainbow_api-1.5.5/rainbow/_version.py +6 -0
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow/agilent/__init__.py +102 -9
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow/agilent/chemstation.py +32 -3
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow/agilent/masshunter.py +37 -10
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow/agilent/openlab.py +15 -2
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow/agilent/sequence.py +22 -1
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow/asm.py +1360 -189
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow/datadirectory.py +1 -1
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow/datafile.py +5 -2
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow/datasequence.py +7 -7
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow/waters/masslynx.py +11 -3
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow_api.egg-info/PKG-INFO +1 -1
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow_api.egg-info/SOURCES.txt +2 -0
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/COPYING +0 -0
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/COPYING.LESSER +0 -0
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/MANIFEST.in +0 -0
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/README.md +0 -0
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow/_arguments.py +0 -0
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow/_binning.py +0 -0
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow/agilent/_chdelta.pyx +0 -0
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow/agilent/_msprofile.pyx +0 -0
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow/agilent/_uvdelta.pyx +0 -0
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow/agilent/acaml.py +0 -0
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow/agilent/method.py +0 -0
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow/debug/__init__.py +0 -0
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow/debug/_util.py +0 -0
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow/debug/chemstation_header.py +0 -0
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow/debug/chemstation_text.py +0 -0
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow/debug/dotnet.py +0 -0
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow/debug/ini.py +0 -0
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow/debug/method.py +0 -0
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow/debug/mzxml.py +0 -0
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow/debug/reg.py +0 -0
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow/debug/waters_header.py +0 -0
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow/debug/waters_inf.py +0 -0
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow/debug/xml.py +0 -0
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow/waters/__init__.py +0 -0
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow_api.egg-info/dependency_links.txt +0 -0
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow_api.egg-info/requires.txt +0 -0
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/rainbow_api.egg-info/top_level.txt +0 -0
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/setup.cfg +0 -0
- {rainbow_api-1.5.4 → rainbow_api-1.5.5}/setup.py +0 -0
|
@@ -3,6 +3,139 @@
|
|
|
3
3
|
All notable changes to `rainbow-api` are documented here. This project adheres
|
|
4
4
|
to [Semantic Versioning](https://semver.org/).
|
|
5
5
|
|
|
6
|
+
## [1.5.5] - 2026-10-17
|
|
7
|
+
|
|
8
|
+
### Added
|
|
9
|
+
- **`rb.from_asm` and `rb.sequence_from_asm` read every measurement's peaks.**
|
|
10
|
+
They read a measurement's peaks only beside a rebuilt trace, and rebuilt
|
|
11
|
+
only absorbance cubes with inline data, so the peaks of every fluorescence
|
|
12
|
+
channel, of an FID run, and of every measurement in an index document
|
|
13
|
+
(whose cubes carry no values) were dropped. Over 531 local Empower and
|
|
14
|
+
OpenLab exports, 1.5.4 read 15,503 of 20,026 peaks; 1.5.5 reads all of them.
|
|
15
|
+
Each peak group also carries the channel's `detector` and `metadata`, so a
|
|
16
|
+
group with no trace beside it still says which channel it was integrated on.
|
|
17
|
+
- **Peaks carry their units, identifier and index.** `area_unit` and
|
|
18
|
+
`height_unit` say what each value is in; `identifier` and `index` are the
|
|
19
|
+
peak's own; each integration's `processing` gains its `description`.
|
|
20
|
+
- **More of the envelope.** `injection_time`, `sample_role`, `well_plate_id`
|
|
21
|
+
and `acq_method`, and the `data_system`, `analysis_sequence` and `project`
|
|
22
|
+
records, field by field as written; all are written back on export (see the
|
|
23
|
+
round-trip guide for where). A `scalar integer datum` reads as an `int`.
|
|
24
|
+
- **`rb.read(path, peaks=True)`** attaches one injection's integrated peaks,
|
|
25
|
+
found as `read_sequence(peaks=True)` finds them: the `sequence.acaml` beside
|
|
26
|
+
the .D, else its own `sequence.acam_`.
|
|
27
|
+
- **`rb.peaks_from_asm(measurement)`** reads one ASM measurement document's
|
|
28
|
+
peaks. **`rb.sniff_vendor(path)`** is the content check `rb.read` falls back
|
|
29
|
+
to for an unsuffixed folder, and **`rb.asm_technique(run)`** is the `"LC"` or
|
|
30
|
+
`"GC"` the export will use.
|
|
31
|
+
- **`rainbow.__version__`**, the version an export names as its converter.
|
|
32
|
+
|
|
33
|
+
### Changed
|
|
34
|
+
- **Every chromatogram cube is rebuilt, not only absorbance.** Fluorescence,
|
|
35
|
+
electric current, intensity, refractive index and conductivity channels come
|
|
36
|
+
back as DataFiles with `metadata["unit"]` as written and
|
|
37
|
+
`metadata["measure"]`. The detector is named from the device type, then the
|
|
38
|
+
device identifier, then the cube label, then the measure: `UV`, `RID`, `FLD`
|
|
39
|
+
(new), `ELSD`, `FID`, or `CAD`; a channel rainbow has no name for, such as a
|
|
40
|
+
conductivity detector, is detector `None` and joins the directory's
|
|
41
|
+
`analog` traces. The channel metadata also holds `device_type` and
|
|
42
|
+
`acq_method`, and the optics from the device control settings, the cube
|
|
43
|
+
label, or the processed data description: `wavelength`, `bandwidth`,
|
|
44
|
+
`reference_wavelength`, `reference_bandwidth`, and a fluorescence channel's
|
|
45
|
+
`excitation_wavelength`, `excitation_bandwidth` and `emission_wavelength`.
|
|
46
|
+
- **A peak's `height` and `area` on a non-absorbance channel are kept as
|
|
47
|
+
written.** 1.5.4 read any unit it could not convert to mAU as `None`, which
|
|
48
|
+
lost every fluorescence peak, and converted µV to mAU whatever the channel
|
|
49
|
+
measured. An RFU, pA or ELSD µV value now comes back with its unit. Only on
|
|
50
|
+
an absorbance channel is AU or Empower's µV converted to mAU; the edge
|
|
51
|
+
heights are in the height's unit.
|
|
52
|
+
- **`Ref=off` reads as `reference_wavelength` None**, present, in the vendor
|
|
53
|
+
readers and in `from_asm`, so a channel without a reference is told apart
|
|
54
|
+
from one whose reference was not recorded. Code that reads
|
|
55
|
+
`metadata["reference_wavelength"]` may now find the key with the value
|
|
56
|
+
`None`, where it used to be absent.
|
|
57
|
+
|
|
58
|
+
### Fixed
|
|
59
|
+
- **`to_asm` wrote every peak area as `mAU.s`**, an FID's or CAD's pA.s
|
|
60
|
+
included. A peak's area and height are now written in the unit of the cube
|
|
61
|
+
it was integrated on. REC/2026/06 gives electric current (pA), intensity
|
|
62
|
+
(RLU), voltage (mV) and fluorescence (RFU) their own peak lists, so such
|
|
63
|
+
a channel keeps its faithful cube when it carries peaks; only
|
|
64
|
+
a measure with no peak list in the schema (nA, V) is still relabeled to
|
|
65
|
+
absorbance. The relabel note now also records the real concept and unit as
|
|
66
|
+
structured custom information, and `from_asm` reads it (or the sentence
|
|
67
|
+
1.5.4 wrote alone) to put the channel and its peaks back in their real
|
|
68
|
+
unit, so a relabeled channel re-exports to a valid document.
|
|
69
|
+
- **A fluorescence signal is FLD in every Agilent reader.** "FLD1 A, Ex=230,
|
|
70
|
+
Em=310" was typed UV at 230 nm in a ChemStation .ch; it is now an `FLD`
|
|
71
|
+
channel with `excitation_wavelength` and `emission_wavelength`, labelled by
|
|
72
|
+
its emission, in the .ch, OpenLab .dx and MassHunter .cg readers alike, and
|
|
73
|
+
`parse_optics` reads the `Ex=`/`Em=` clause. In the 179/181 .ch container
|
|
74
|
+
1.5.4 typed it FID instead, which also exported the whole run as gas
|
|
75
|
+
chromatography.
|
|
76
|
+
- **`from_asm` scales an absorbance trace to mAU.** A cube in AU (or Empower's
|
|
77
|
+
µV) was rebuilt in its own unit while its peaks' heights and areas were
|
|
78
|
+
converted to mAU, so the trace minus an edge height was a thousand times
|
|
79
|
+
off. The trace is now scaled to mAU too, the unit rainbow holds UV data in
|
|
80
|
+
and to_asm writes, and `metadata["unit"]` says so.
|
|
81
|
+
- **The processing time and description are where REC/2026/06 puts them.**
|
|
82
|
+
`data processing time` is written in the data processing document, stamped
|
|
83
|
+
with `utc_offset=` (as custom information when it has no offset), and the
|
|
84
|
+
description under `description`, the name REC/2026/06 gave the 2025/03
|
|
85
|
+
`processed data description`; both are read from any of those places. A
|
|
86
|
+
sample role outside the schema's list is written as custom information.
|
|
87
|
+
- **Every peak and peak group has the same keys, whatever it was read from.**
|
|
88
|
+
A peak read from a vendor result document carries `identifier`, `index`,
|
|
89
|
+
`area_unit`, `height_unit`, `start_height`, `end_height` and the four
|
|
90
|
+
baseline keys too, as None, and its group `detector`, `metadata` and
|
|
91
|
+
`processing` as None and `alternates` as an empty list.
|
|
92
|
+
- **A unit published under another's name reads back as itself.** A
|
|
93
|
+
channel whose unit the schema has no term for (red.D's CAD in mAu) is
|
|
94
|
+
published under its detector's default unit, as before, and now with the
|
|
95
|
+
structured note a peak relabel writes, so `from_asm` restores its unit and
|
|
96
|
+
its peaks'. A peak area in a unit per minute is converted to per second,
|
|
97
|
+
and an absorbance area per an unknown time reads as None.
|
|
98
|
+
- **A re-exported data system record names rainbow as its converter.**
|
|
99
|
+
`ASM converter name` and `version` are rainbow-api's, `ASM conversion time`
|
|
100
|
+
is the time of the export (so two exports differ there), and `ASM file
|
|
101
|
+
identifier` is the file written, else one named for the run; the source
|
|
102
|
+
converter's are kept as the record's custom information, prefixed
|
|
103
|
+
`source`, and a second round trip keeps them as they were (the source
|
|
104
|
+
conversion time exactly as written). A record naming both a file and a
|
|
105
|
+
database row keeps the row and carries the file as custom information. The
|
|
106
|
+
record's times take `utc_offset=`. Every chromatogram channel's device
|
|
107
|
+
control keeps the source's device identifier (read into
|
|
108
|
+
`metadata["device_identifier"]`), names the detector there only when the
|
|
109
|
+
source had none, and names rainbow's detector in its custom information
|
|
110
|
+
(`rainbow detector`), which is what reads it back.
|
|
111
|
+
- **Bandwidth, reference and acquisition method survive a round trip.** A UV
|
|
112
|
+
channel's bandwidth and reference are written as their device control
|
|
113
|
+
settings (Ref=off as custom information), an FLD's excitation bandwidth
|
|
114
|
+
too, and the acquisition method as the measurement's custom information.
|
|
115
|
+
A CAD's device control names it in its device identifier, so rainbow's
|
|
116
|
+
own export reads back as CAD.
|
|
117
|
+
- **A vendor peak group names its detector and its peaks' units.**
|
|
118
|
+
`rb.read(peaks=True)` and `read_sequence(peaks=True)` fill each group's
|
|
119
|
+
`detector` and `metadata` from the channel's DataFile, and each peak's
|
|
120
|
+
`height_unit` and `area_unit` from its unit (the peak table is in the
|
|
121
|
+
channel's unit, per second for an area, and does not say so).
|
|
122
|
+
- **The detector is not read from a measurement identifier.** It is a key
|
|
123
|
+
(often a GUID), and a segment such as `adc4` typed a channel CAD.
|
|
124
|
+
- **A gas chromatography document re-exports as one.** `from_asm` records
|
|
125
|
+
the document's technique in `metadata["technique"]`, which the export
|
|
126
|
+
follows; one with no FID channel used to come back as liquid
|
|
127
|
+
chromatography.
|
|
128
|
+
- **A peak in AU or µV beside an absorbance cube is converted to mAU on
|
|
129
|
+
export**, as the cube is, rather than relabeled 1000 times off; a peak
|
|
130
|
+
group's `metadata["unit"]` is mAU when its trace is.
|
|
131
|
+
- **A ChemStation FLD channel is FLD by its name too**, as OpenLab's is by
|
|
132
|
+
its device, when its wavelengths are not numbers.
|
|
133
|
+
- **A Waters fluorescence channel is FLD.** One fluorescence parser serves
|
|
134
|
+
the Agilent readers, the Waters reader and `from_asm`.
|
|
135
|
+
- **`to_asm` dropped peak groups no exported channel carries** (peaks read from
|
|
136
|
+
an index document, or on an analog channel) without a word. It warns once
|
|
137
|
+
per group.
|
|
138
|
+
|
|
6
139
|
## [1.5.4] - 2026-10-17
|
|
7
140
|
|
|
8
141
|
### Added
|
|
@@ -1,11 +1,13 @@
|
|
|
1
1
|
import os
|
|
2
2
|
import re
|
|
3
|
+
from rainbow._version import __version__
|
|
3
4
|
from rainbow.datafile import DataFile
|
|
4
5
|
from rainbow.datadirectory import DataDirectory
|
|
5
6
|
from rainbow.datasequence import DataSequence
|
|
6
7
|
from rainbow import agilent, waters
|
|
7
8
|
from rainbow._binning import MZ_FLOORS
|
|
8
|
-
from rainbow.asm import from_asm, iso_timestamp,
|
|
9
|
+
from rainbow.asm import (asm_technique, from_asm, iso_timestamp,
|
|
10
|
+
peaks_from_asm, sequence_from_asm)
|
|
9
11
|
|
|
10
12
|
|
|
11
13
|
# `debug` is listed although it is not imported above: __getattr__ fetches it on
|
|
@@ -15,7 +17,8 @@ __all__ = [
|
|
|
15
17
|
'DataFile', 'DataDirectory', 'DataSequence',
|
|
16
18
|
'agilent', 'waters', 'debug',
|
|
17
19
|
'read', 'read_sequence', 'read_metadata', 'mz_resolution',
|
|
18
|
-
'from_asm', 'sequence_from_asm', 'iso_timestamp',
|
|
20
|
+
'from_asm', 'sequence_from_asm', 'peaks_from_asm', 'iso_timestamp',
|
|
21
|
+
'asm_technique', 'sniff_vendor',
|
|
19
22
|
'VENDORS', 'MZ_FLOORS',
|
|
20
23
|
]
|
|
21
24
|
|
|
@@ -114,19 +117,22 @@ def _warn_bin_width_floor(datafiles, bin_width, vendor):
|
|
|
114
117
|
f"{described}; it only inserts empty bins.")
|
|
115
118
|
|
|
116
119
|
|
|
117
|
-
def
|
|
120
|
+
def sniff_vendor(path):
|
|
118
121
|
"""
|
|
119
122
|
Identifies the vendor of a directory from its contents.
|
|
120
123
|
|
|
121
|
-
|
|
122
|
-
suffix (e.g. a Waters .raw folder renamed to
|
|
123
|
-
|
|
124
|
+
:func:`read` falls back to this when a directory's name lacks the
|
|
125
|
+
conventional vendor suffix (e.g. a Waters .raw folder renamed to
|
|
126
|
+
``Caffeine 3``), so a caller deciding whether a folder is a run rainbow
|
|
127
|
+
can read asks the same question :func:`read` will. The name is not
|
|
128
|
+
consulted, so a ``.D`` folder holding nothing rainbow recognizes is None.
|
|
124
129
|
|
|
125
130
|
Args:
|
|
126
131
|
path (str): Path of the directory.
|
|
127
132
|
|
|
128
133
|
Returns:
|
|
129
|
-
|
|
134
|
+
'agilent', 'waters', or None if no signature matches (or the path is
|
|
135
|
+
not a directory).
|
|
130
136
|
|
|
131
137
|
"""
|
|
132
138
|
try:
|
|
@@ -149,6 +155,10 @@ def _sniff_vendor(path):
|
|
|
149
155
|
return None
|
|
150
156
|
|
|
151
157
|
|
|
158
|
+
# The name it had while it was private, kept for callers that reached for it.
|
|
159
|
+
_sniff_vendor = sniff_vendor
|
|
160
|
+
|
|
161
|
+
|
|
152
162
|
def _detect_vendor(path):
|
|
153
163
|
"""
|
|
154
164
|
Determines which vendor parser to use for a path.
|
|
@@ -176,7 +186,7 @@ def _detect_vendor(path):
|
|
|
176
186
|
if ext == '.raw':
|
|
177
187
|
return 'waters'
|
|
178
188
|
if os.path.isdir(path):
|
|
179
|
-
return
|
|
189
|
+
return sniff_vendor(path)
|
|
180
190
|
return None
|
|
181
191
|
|
|
182
192
|
|
|
@@ -229,7 +239,7 @@ def _unreadable(path, what="read"):
|
|
|
229
239
|
|
|
230
240
|
def read(path, display_precision='auto', hrms=False, requested_files=None,
|
|
231
241
|
telemetry=False, centroid=False, format=None, bin_width=None,
|
|
232
|
-
_labels_only=False, **removed):
|
|
242
|
+
peaks=False, _labels_only=False, **removed):
|
|
233
243
|
"""
|
|
234
244
|
Reads a chromatogram data directory. Main method of the package.
|
|
235
245
|
|
|
@@ -282,6 +292,13 @@ def read(path, display_precision='auto', hrms=False, requested_files=None,
|
|
|
282
292
|
default) to keep the per-scan representation, or pass a width to
|
|
283
293
|
project the scans onto one shared m/z grid (see
|
|
284
294
|
:ref:`hrms-data-model`).
|
|
295
|
+
peaks (bool, optional): Flag for reading the run's integrated peaks
|
|
296
|
+
into ``DataDirectory.peaks``, as :func:`read_sequence` does for a
|
|
297
|
+
whole sequence. For Agilent they come from the result document of
|
|
298
|
+
the sequence the run sits in (``sequence.acaml`` beside it), or
|
|
299
|
+
else from the run's own (``sequence.acam_`` inside it); a run with
|
|
300
|
+
neither has none. Waters results and a .dx archive's are not
|
|
301
|
+
read; asking for them warns.
|
|
285
302
|
|
|
286
303
|
Returns:
|
|
287
304
|
DataDirectory representing the directory.
|
|
@@ -309,6 +326,9 @@ def read(path, display_precision='auto', hrms=False, requested_files=None,
|
|
|
309
326
|
if not isinstance(telemetry, bool):
|
|
310
327
|
raise Exception("The telemetry flag must be a boolean.")
|
|
311
328
|
|
|
329
|
+
if not isinstance(peaks, bool):
|
|
330
|
+
raise Exception("The peaks flag must be a boolean.")
|
|
331
|
+
|
|
312
332
|
# display_precision is a label precision (decimals for the reported m/z),
|
|
313
333
|
# and is cosmetic: it rounds the labels, never the data. 'auto' is finalized
|
|
314
334
|
# per file inside each parser, where the acquisition is actually known:
|
|
@@ -337,10 +357,18 @@ def read(path, display_precision='auto', hrms=False, requested_files=None,
|
|
|
337
357
|
if vendor == 'agilent':
|
|
338
358
|
datadir = agilent.read(
|
|
339
359
|
path, display_precision, hrms, requested_files, telemetry, centroid,
|
|
340
|
-
bin_width, _labels_only)
|
|
360
|
+
bin_width, peaks=peaks, _labels_only=_labels_only)
|
|
341
361
|
elif vendor == 'waters':
|
|
342
362
|
datadir = waters.read(
|
|
343
363
|
path, display_precision, requested_files, bin_width, _labels_only)
|
|
364
|
+
if peaks and datadir is not None:
|
|
365
|
+
import warnings
|
|
366
|
+
# The run gets an empty list, which alone would read as a run
|
|
367
|
+
# nobody integrated, so the read says why it is empty.
|
|
368
|
+
warnings.warn(
|
|
369
|
+
f"rainbow does not read integrated peaks from Waters data; "
|
|
370
|
+
f"{os.path.basename(path)} is read without them.")
|
|
371
|
+
datadir.peaks = []
|
|
344
372
|
|
|
345
373
|
if datadir is None:
|
|
346
374
|
raise _unreadable(path, "read")
|
|
@@ -626,7 +654,7 @@ def read_sequence(path, display_precision='auto', hrms=False,
|
|
|
626
654
|
"""
|
|
627
655
|
Reads a multi-injection sequence directory.
|
|
628
656
|
|
|
629
|
-
Where :func:`read` reads a single
|
|
657
|
+
Where :func:`read` reads a single run, this reads the whole sequence: a
|
|
630
658
|
directory holding one injection subdirectory per sample, plus the
|
|
631
659
|
sequence-level method and metadata. Each injection is read with
|
|
632
660
|
:func:`read`, and the injections are returned in sorted-name order, which is
|
|
@@ -0,0 +1,33 @@
|
|
|
1
|
+
"""
|
|
2
|
+
The excitation and emission a fluorescence channel's description names.
|
|
3
|
+
|
|
4
|
+
Every reader that types a fluorescence channel asks the same question of a
|
|
5
|
+
vendor's text, in each vendor's spelling: ChemStation and OpenLab write
|
|
6
|
+
"FLD1 A, Ex=230, Em=310", Empower "ACQUITY FLR ChA Ex280,Em340 nm". One parser
|
|
7
|
+
answers it for all of them, so no two readers can disagree about which
|
|
8
|
+
channel is a fluorescence one, or about its wavelengths.
|
|
9
|
+
"""
|
|
10
|
+
import re
|
|
11
|
+
|
|
12
|
+
_NUMBER = r"(\d+(?:\.\d+)?)"
|
|
13
|
+
|
|
14
|
+
EXCITATION_EMISSION_RE = re.compile(
|
|
15
|
+
r"\bEx\s*[:=]?\s*" + _NUMBER + r"\s*(?:nm)?\s*[,/ ]\s*Em\s*[:=]?\s*"
|
|
16
|
+
+ _NUMBER, re.IGNORECASE)
|
|
17
|
+
|
|
18
|
+
|
|
19
|
+
def excitation_emission(text):
|
|
20
|
+
"""
|
|
21
|
+
The ``(excitation, emission)`` wavelengths ``text`` names, in nm, or None.
|
|
22
|
+
|
|
23
|
+
Args:
|
|
24
|
+
text (str): A signal description, channel name, or cube label.
|
|
25
|
+
|
|
26
|
+
Returns:
|
|
27
|
+
tuple: Two floats, or None when the text names no Ex/Em pair.
|
|
28
|
+
|
|
29
|
+
"""
|
|
30
|
+
match = EXCITATION_EMISSION_RE.search(text) if text else None
|
|
31
|
+
if match is None:
|
|
32
|
+
return None
|
|
33
|
+
return float(match.group(1)), float(match.group(2))
|
|
@@ -0,0 +1,6 @@
|
|
|
1
|
+
# The version of rainbow-api this source tree is, which an export names as its
|
|
2
|
+
# converter. It has to match pyproject.toml's; tests/test_asm_roundtrip.py
|
|
3
|
+
# checks that they agree. Read from here rather than from the installed
|
|
4
|
+
# distribution's metadata, which an editable install leaves at whatever
|
|
5
|
+
# version it was installed as.
|
|
6
|
+
__version__ = "1.5.5"
|
|
@@ -8,8 +8,8 @@ from rainbow.datasequence import DataSequence
|
|
|
8
8
|
|
|
9
9
|
|
|
10
10
|
def read(path, display_precision='auto', hrms=False, requested_files=None,
|
|
11
|
-
telemetry=False, centroid=False, bin_width=None,
|
|
12
|
-
**removed):
|
|
11
|
+
telemetry=False, centroid=False, bin_width=None, peaks=False,
|
|
12
|
+
_labels_only=False, **removed):
|
|
13
13
|
"""
|
|
14
14
|
Reads an Agilent .D directory or .dx archive.
|
|
15
15
|
|
|
@@ -32,6 +32,8 @@ def read(path, display_precision='auto', hrms=False, requested_files=None,
|
|
|
32
32
|
representation (one
|
|
33
33
|
:class:`~rainbow.agilent.masshunter.ProfileDataFile` per flight-time
|
|
34
34
|
grid), or pass a width to project onto the shared m/z grid.
|
|
35
|
+
peaks (bool, optional): Flag for reading the run's integrated peaks
|
|
36
|
+
into ``DataDirectory.peaks`` (see :func:`injection_peaks`).
|
|
35
37
|
|
|
36
38
|
Returns:
|
|
37
39
|
DataDirectory representing the Agilent data.
|
|
@@ -46,8 +48,19 @@ def read(path, display_precision='auto', hrms=False, requested_files=None,
|
|
|
46
48
|
validate_bin_width(bin_width)
|
|
47
49
|
if os.path.splitext(path)[1].lower() == '.dx':
|
|
48
50
|
from rainbow.agilent import openlab
|
|
49
|
-
|
|
51
|
+
datadir = openlab.read(
|
|
50
52
|
path, display_precision, requested_files, telemetry, bin_width)
|
|
53
|
+
if peaks and datadir is not None:
|
|
54
|
+
# An archive's results are not read. The run gets an empty list,
|
|
55
|
+
# which alone would read as a run nobody integrated, so the read
|
|
56
|
+
# says why it is empty.
|
|
57
|
+
import warnings
|
|
58
|
+
warnings.warn(
|
|
59
|
+
"rainbow does not read integrated peaks from an OpenLab .dx "
|
|
60
|
+
"archive; {} is read without them.".format(
|
|
61
|
+
os.path.basename(path)))
|
|
62
|
+
datadir.peaks = []
|
|
63
|
+
return datadir
|
|
51
64
|
|
|
52
65
|
datafiles = []
|
|
53
66
|
datafiles.extend(chemstation.parse_allfiles(
|
|
@@ -92,7 +105,49 @@ def read(path, display_precision='auto', hrms=False, requested_files=None,
|
|
|
92
105
|
os.path.join(path, "AcqData", "MSPeak.bin")):
|
|
93
106
|
metadata['centroid_available'] = True
|
|
94
107
|
|
|
95
|
-
|
|
108
|
+
datadir = DataDirectory(path, datafiles, metadata)
|
|
109
|
+
if peaks:
|
|
110
|
+
datadir.peaks = _with_channels(datadir, injection_peaks(path))
|
|
111
|
+
return datadir
|
|
112
|
+
|
|
113
|
+
|
|
114
|
+
def injection_peaks(path):
|
|
115
|
+
"""
|
|
116
|
+
Reads the integrated peaks of one injection .D directory.
|
|
117
|
+
|
|
118
|
+
The same peaks :func:`read_sequence` attaches to the injection, found the
|
|
119
|
+
same way: from the ``sequence.acaml`` of the sequence directory the .D
|
|
120
|
+
sits in, matched by the .D's folder name, or failing that from the .D's
|
|
121
|
+
own ``sequence.acam_``.
|
|
122
|
+
|
|
123
|
+
Each call parses the whole result document, which for a sequence holds
|
|
124
|
+
every injection's results. To read the peaks of many injections of one
|
|
125
|
+
sequence, ``read_sequence(path, peaks=True)`` parses it once for all of
|
|
126
|
+
them and is the efficient path.
|
|
127
|
+
|
|
128
|
+
Args:
|
|
129
|
+
path (str): Path of the .D directory.
|
|
130
|
+
|
|
131
|
+
Returns:
|
|
132
|
+
list: The injection's signal groups (see
|
|
133
|
+
:func:`rainbow.agilent.sequence.parse_peaks`), or ``[]`` when no
|
|
134
|
+
result document covers it.
|
|
135
|
+
|
|
136
|
+
"""
|
|
137
|
+
from rainbow.agilent import sequence
|
|
138
|
+
# Absolute, so a relative path such as "run.D" still has a parent
|
|
139
|
+
# directory to look for the sequence.acaml in.
|
|
140
|
+
path = os.path.abspath(path)
|
|
141
|
+
name = os.path.basename(path)
|
|
142
|
+
sequence_acaml = sequence.find(os.path.dirname(path) or os.curdir)
|
|
143
|
+
groups = None
|
|
144
|
+
if sequence_acaml is not None:
|
|
145
|
+
groups = {injection.lower(): found for injection, found
|
|
146
|
+
in sequence.parse_peaks(sequence_acaml).items()
|
|
147
|
+
}.get(name.lower())
|
|
148
|
+
if not groups:
|
|
149
|
+
groups = _own_peaks(name, path)
|
|
150
|
+
return groups or []
|
|
96
151
|
|
|
97
152
|
|
|
98
153
|
def injection_dirs(path):
|
|
@@ -167,7 +222,7 @@ def read_sequence(path, display_precision='auto', hrms=False,
|
|
|
167
222
|
metadata = {'injection_count': len(injections)}
|
|
168
223
|
|
|
169
224
|
# Merge the sequence-level document (instrument, operator), and let its
|
|
170
|
-
#
|
|
225
|
+
# sequence-wide operator fill any injection that lacked one.
|
|
171
226
|
from rainbow.agilent import sequence
|
|
172
227
|
sequence_acaml = sequence.find(path)
|
|
173
228
|
if sequence_acaml is not None:
|
|
@@ -213,11 +268,49 @@ def _attach_peaks(injections, injection_paths, sequence_acaml):
|
|
|
213
268
|
for injection, injection_path in zip(injections, injection_paths):
|
|
214
269
|
groups = folded.get(injection.name.lower())
|
|
215
270
|
if not groups:
|
|
216
|
-
groups =
|
|
217
|
-
injection.peaks = groups or []
|
|
271
|
+
groups = _own_peaks(injection.name, injection_path)
|
|
272
|
+
injection.peaks = _with_channels(injection, groups or [])
|
|
273
|
+
|
|
274
|
+
|
|
275
|
+
def _with_channels(datadir, groups):
|
|
276
|
+
"""``groups`` with each one's detector and metadata from its DataFile.
|
|
277
|
+
|
|
278
|
+
A result document names the channel a signal was integrated on but not
|
|
279
|
+
its detector, which the run's own file for that channel does say. A
|
|
280
|
+
group whose channel the run did not read keeps None.
|
|
281
|
+
"""
|
|
282
|
+
by_key = {os.path.splitext(datafile.name)[0].upper(): datafile
|
|
283
|
+
for datafile in datadir.datafiles + datadir.analog}
|
|
284
|
+
for group in groups:
|
|
285
|
+
channel = group.get("channel_file") or group.get("signal") or ""
|
|
286
|
+
datafile = by_key.get(
|
|
287
|
+
os.path.splitext(channel)[0].replace(" ", "").upper())
|
|
288
|
+
if datafile is not None:
|
|
289
|
+
group["detector"] = datafile.detector
|
|
290
|
+
group["metadata"] = dict(datafile.metadata)
|
|
291
|
+
_fill_units(group, datafile.metadata.get("unit"))
|
|
292
|
+
return groups
|
|
218
293
|
|
|
219
294
|
|
|
220
|
-
def
|
|
295
|
+
def _fill_units(group, unit):
|
|
296
|
+
"""Gives a group's peaks the channel's unit where they state none.
|
|
297
|
+
|
|
298
|
+
ChemStation's peak table is in the channel's unit, a height in it and an
|
|
299
|
+
area in it per second, but does not say so.
|
|
300
|
+
"""
|
|
301
|
+
if not unit:
|
|
302
|
+
return
|
|
303
|
+
lists = [group["peaks"]] + [alternate["peaks"] for alternate
|
|
304
|
+
in group.get("alternates") or []]
|
|
305
|
+
for peaks in lists:
|
|
306
|
+
for peak in peaks:
|
|
307
|
+
if peak.get("height_unit") is None:
|
|
308
|
+
peak["height_unit"] = unit
|
|
309
|
+
if peak.get("area_unit") is None:
|
|
310
|
+
peak["area_unit"] = unit + ".s"
|
|
311
|
+
|
|
312
|
+
|
|
313
|
+
def _own_peaks(injection_name, injection_path):
|
|
221
314
|
"""Peaks from an injection's own result document (sequence.acam_)."""
|
|
222
315
|
from rainbow.agilent import sequence
|
|
223
316
|
document = sequence.find_result_document(injection_path)
|
|
@@ -227,7 +320,7 @@ def _injection_peaks(injection, injection_path):
|
|
|
227
320
|
if not by_injection:
|
|
228
321
|
return None
|
|
229
322
|
folded = {name.lower(): groups for name, groups in by_injection.items()}
|
|
230
|
-
groups = folded.get(
|
|
323
|
+
groups = folded.get(injection_name.lower())
|
|
231
324
|
if groups is None and len(by_injection) == 1:
|
|
232
325
|
# A per-injection document holds exactly this injection's peaks.
|
|
233
326
|
groups = next(iter(by_injection.values()))
|
|
@@ -18,6 +18,7 @@ except ImportError:
|
|
|
18
18
|
import xml.etree.ElementTree as etree
|
|
19
19
|
from rainbow.datafile import DataFile
|
|
20
20
|
from rainbow._binning import bin_datapairs
|
|
21
|
+
from rainbow._optics import excitation_emission
|
|
21
22
|
|
|
22
23
|
# Optional compiled accelerators for the delta decode loops.
|
|
23
24
|
# Falls back to the pure-Python implementations below if not built.
|
|
@@ -42,6 +43,10 @@ _MS_INT_POW8 = np.array([1, 8, 64, 512], dtype=np.uint32)
|
|
|
42
43
|
# and other detectors have no Sig= clause. Shared with the OpenLab .dx parser.
|
|
43
44
|
_SIG_RE = re.compile(r'Sig=([\d.]+),([\d.]+)')
|
|
44
45
|
_REF_RE = re.compile(r'Ref=([\d.]+),([\d.]+)')
|
|
46
|
+
_REF_OFF_RE = re.compile(r'Ref=off\b', re.IGNORECASE)
|
|
47
|
+
|
|
48
|
+
# A fluorescence detector names its channels FLD1A, "FLD1 A", ...
|
|
49
|
+
_FLD_SIGNAL_RE = re.compile(r'\s*FLD\d', re.IGNORECASE)
|
|
45
50
|
|
|
46
51
|
# Not every single-wavelength channel writes a Sig= clause. A variable- or
|
|
47
52
|
# multi-wavelength detector often spells the same setting out, e.g.
|
|
@@ -55,12 +60,23 @@ def parse_optics(description):
|
|
|
55
60
|
|
|
56
61
|
Returns a dict with any of ``wavelength``, ``bandwidth``,
|
|
57
62
|
``reference_wavelength``, and ``reference_bandwidth`` (in nm), parsed from
|
|
58
|
-
the ``Sig=``/``Ref=`` clause of a single-wavelength channel.
|
|
59
|
-
|
|
60
|
-
|
|
63
|
+
the ``Sig=``/``Ref=`` clause of a single-wavelength channel. ``Ref=off``
|
|
64
|
+
gives a ``reference_wavelength`` of None: the channel states that it has
|
|
65
|
+
no reference, which is not the same as stating nothing about one, and two
|
|
66
|
+
channels at one wavelength differ by it. A fluorescence channel's
|
|
67
|
+
``Ex=``/``Em=`` clause gives ``excitation_wavelength`` and
|
|
68
|
+
``emission_wavelength`` instead. Descriptions without such a clause
|
|
69
|
+
(spectra, FID, telemetry) yield an empty dict.
|
|
61
70
|
|
|
62
71
|
"""
|
|
63
72
|
optics = {}
|
|
73
|
+
# A fluorescence channel names its excitation and emission instead, e.g.
|
|
74
|
+
# "FLD1 A, Ex=230, Em=310". Its first number is the excitation, so reading
|
|
75
|
+
# it as a UV wavelength put a fluorescence trace at 230 nm absorbance.
|
|
76
|
+
pair = excitation_emission(description)
|
|
77
|
+
if pair:
|
|
78
|
+
optics['excitation_wavelength'], optics['emission_wavelength'] = pair
|
|
79
|
+
return optics
|
|
64
80
|
sig = _SIG_RE.search(description)
|
|
65
81
|
if sig:
|
|
66
82
|
optics['wavelength'] = float(sig.group(1))
|
|
@@ -69,6 +85,8 @@ def parse_optics(description):
|
|
|
69
85
|
if ref:
|
|
70
86
|
optics['reference_wavelength'] = float(ref.group(1))
|
|
71
87
|
optics['reference_bandwidth'] = float(ref.group(2))
|
|
88
|
+
elif _REF_OFF_RE.search(description):
|
|
89
|
+
optics['reference_wavelength'] = None
|
|
72
90
|
return optics
|
|
73
91
|
|
|
74
92
|
"""
|
|
@@ -205,6 +223,17 @@ def _detector_from_signal(metadata, default=None, uv_only=False):
|
|
|
205
223
|
return 'UV', sig.group(1)
|
|
206
224
|
if 'ADC' in signal:
|
|
207
225
|
return ('ELSD' if 'CHANNEL' in signal else 'CAD'), ''
|
|
226
|
+
optics = parse_optics(signal)
|
|
227
|
+
if 'emission_wavelength' in optics:
|
|
228
|
+
# The y-axis label is the emission, the wavelength the detector
|
|
229
|
+
# measures at, as rb.from_asm labels a fluorescence channel.
|
|
230
|
+
metadata.update(optics)
|
|
231
|
+
return 'FLD', str(optics['emission_wavelength'])
|
|
232
|
+
if _FLD_SIGNAL_RE.match(signal):
|
|
233
|
+
# A fluorescence detector's own channel whose wavelengths are not
|
|
234
|
+
# spelled as numbers (a scan, a program): still FLD, as OpenLab types
|
|
235
|
+
# it by its device, rather than falling through to the FID default.
|
|
236
|
+
return 'FLD', ''
|
|
208
237
|
if uv_only:
|
|
209
238
|
# The 130/30 container holds no flame ionization channel, so the
|
|
210
239
|
# ambiguity that forces the Sig= clause on 179/181 does not arise here:
|
|
@@ -3,6 +3,7 @@ Methods for parsing Agilent Masshunter files.
|
|
|
3
3
|
|
|
4
4
|
"""
|
|
5
5
|
import os
|
|
6
|
+
import re
|
|
6
7
|
import struct
|
|
7
8
|
import warnings
|
|
8
9
|
import numpy as np
|
|
@@ -348,8 +349,14 @@ _SD_WAVELENGTH_END = 56 # f64, nm
|
|
|
348
349
|
# spectrum with its wavelengths, a .cg chromatogram with its retention times.
|
|
349
350
|
_AXIS_PREFIX_SIZE = 16 # f64 start + f64 step
|
|
350
351
|
|
|
351
|
-
# Devices
|
|
352
|
-
|
|
352
|
+
# Devices whose .cd/.cg chromatograms are read as detector signals, matching
|
|
353
|
+
# the Chemstation naming: the absorbance detectors, and a fluorescence
|
|
354
|
+
# detector, which writes the same pair. The pumps and column compartments,
|
|
355
|
+
# whose pairs hold only telemetry, are not among them.
|
|
356
|
+
_DAD_DEVICES = ('DAD', 'MWD', 'VWD', 'FLD')
|
|
357
|
+
|
|
358
|
+
# A description naming an excitation or emission, numeric or not.
|
|
359
|
+
_NAMES_EX_EM_RE = re.compile(r'\b(?:Ex|Em)\b', re.IGNORECASE)
|
|
353
360
|
|
|
354
361
|
|
|
355
362
|
def parse_dadfiles(path, telemetry=False, requested_files=None, listing=None):
|
|
@@ -414,7 +421,10 @@ def parse_dadfiles(path, telemetry=False, requested_files=None, listing=None):
|
|
|
414
421
|
# The spectra are one file under one name, so unlike the chromatograms
|
|
415
422
|
# they match a request exactly - a name that is merely similar is not a
|
|
416
423
|
# file anyone asked for.
|
|
417
|
-
|
|
424
|
+
# Only an absorbance detector's spectra are absorbance spectra; a
|
|
425
|
+
# fluorescence detector's would be read as UV.
|
|
426
|
+
if (stem[:3].upper() != 'FLD'
|
|
427
|
+
and os.path.isfile(spectra_path) and os.path.isfile(desc_path)
|
|
418
428
|
and (not requested_files
|
|
419
429
|
or os.path.basename(spectra_path).lower() in requested_files)):
|
|
420
430
|
spectra = parse_dadspectra(spectra_path, desc_path)
|
|
@@ -569,14 +579,26 @@ def parse_dadchroms(path, signals, telemetry=False, requested_files=None):
|
|
|
569
579
|
|
|
570
580
|
for signal in signals:
|
|
571
581
|
# An absorbance signal is named the Chemstation way ("Sig=254.0,..."),
|
|
572
|
-
# and carries mAU; the detector's telemetry traces have neither.
|
|
573
|
-
|
|
574
|
-
|
|
582
|
+
# and carries mAU; the detector's telemetry traces have neither. A
|
|
583
|
+
# fluorescence signal names its excitation and emission ("Ex=230,
|
|
584
|
+
# Em=310") in any unit.
|
|
585
|
+
optics = parse_optics(signal['description'])
|
|
586
|
+
# In an FLD's own file, a signal that names an excitation or emission
|
|
587
|
+
# in any form ("Ex=Scan"), or reads in its luminescence units, is a
|
|
588
|
+
# fluorescence signal too, not one of the detector's telemetry traces.
|
|
589
|
+
is_fluorescence = 'emission_wavelength' in optics or (
|
|
590
|
+
stem[:3].upper() == 'FLD'
|
|
591
|
+
and (_NAMES_EX_EM_RE.search(signal['description'])
|
|
592
|
+
or signal['unit'].strip().upper() == 'LU'))
|
|
593
|
+
is_absorbance = not is_fluorescence and (
|
|
594
|
+
signal['unit'].lower() == 'mau'
|
|
595
|
+
or signal['description'].startswith('Sig='))
|
|
575
596
|
signal_name = f"{stem}{signal['letter']}.cg".lower()
|
|
576
597
|
requested = bool(requested_files) and signal_name in requested_files
|
|
577
598
|
# Naming a telemetry trace explicitly parses it whether or not the flag
|
|
578
599
|
# is set, as it does for .dx telemetry.
|
|
579
|
-
if not is_absorbance and not telemetry
|
|
600
|
+
if not (is_absorbance or is_fluorescence) and not telemetry \
|
|
601
|
+
and not requested:
|
|
580
602
|
continue
|
|
581
603
|
if requested_files and not (requested or filename in requested_files):
|
|
582
604
|
continue
|
|
@@ -599,11 +621,16 @@ def parse_dadchroms(path, signals, telemetry=False, requested_files=None):
|
|
|
599
621
|
# filename (DAD1A.ch), keeping this format's own extension: here all
|
|
600
622
|
# the signals share one file, so the letter is what tells them apart.
|
|
601
623
|
name = os.path.join(os.path.dirname(path), f"{stem}{signal['letter']}.cg")
|
|
624
|
+
if is_fluorescence:
|
|
625
|
+
detector, ylabel = 'FLD', optics.get('emission_wavelength', '')
|
|
626
|
+
else:
|
|
627
|
+
detector = 'UV' if is_absorbance else None
|
|
628
|
+
ylabel = _signal_wavelength(signal['description'])
|
|
602
629
|
datafiles.append(DataFile(
|
|
603
630
|
name,
|
|
604
|
-
|
|
631
|
+
detector,
|
|
605
632
|
times,
|
|
606
|
-
np.array([
|
|
633
|
+
np.array([ylabel]),
|
|
607
634
|
values.reshape(-1, 1).copy(),
|
|
608
635
|
# The description follows the Chemstation convention, so its optics
|
|
609
636
|
# are surfaced by the same parser the .ch and .dx readers use. A
|
|
@@ -611,7 +638,7 @@ def parse_dadchroms(path, signals, telemetry=False, requested_files=None):
|
|
|
611
638
|
# is what lets an export record the channel's wavelength setting
|
|
612
639
|
# rather than leaving it to be inferred from the ylabel.
|
|
613
640
|
{'signal': signal['description'], 'unit': signal['unit'],
|
|
614
|
-
**
|
|
641
|
+
**optics}))
|
|
615
642
|
|
|
616
643
|
return datafiles
|
|
617
644
|
|