python-homewizard-energy 7.1.0b2__tar.gz → 8.0.0a1__tar.gz
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- {python_homewizard_energy-7.1.0b2 → python_homewizard_energy-8.0.0a1}/PKG-INFO +4 -2
- python_homewizard_energy-8.0.0a1/homewizard_energy/const.py +28 -0
- python_homewizard_energy-8.0.0a1/homewizard_energy/homewizard_energy.py +103 -0
- python_homewizard_energy-8.0.0a1/homewizard_energy/models.py +485 -0
- python_homewizard_energy-8.0.0a1/homewizard_energy/v1/__init__.py +168 -0
- {python_homewizard_energy-7.1.0b2 → python_homewizard_energy-8.0.0a1}/homewizard_energy/v2/__init__.py +28 -61
- {python_homewizard_energy-7.1.0b2 → python_homewizard_energy-8.0.0a1}/pyproject.toml +7 -4
- python_homewizard_energy-7.1.0b2/homewizard_energy/models.py +0 -168
- python_homewizard_energy-7.1.0b2/homewizard_energy/v1/__init__.py +0 -228
- python_homewizard_energy-7.1.0b2/homewizard_energy/v1/models.py +0 -326
- python_homewizard_energy-7.1.0b2/homewizard_energy/v2/models.py +0 -285
- {python_homewizard_energy-7.1.0b2 → python_homewizard_energy-8.0.0a1}/LICENSE +0 -0
- {python_homewizard_energy-7.1.0b2 → python_homewizard_energy-8.0.0a1}/README.md +0 -0
- {python_homewizard_energy-7.1.0b2 → python_homewizard_energy-8.0.0a1}/homewizard_energy/__init__.py +0 -0
- {python_homewizard_energy-7.1.0b2 → python_homewizard_energy-8.0.0a1}/homewizard_energy/errors.py +0 -0
- {python_homewizard_energy-7.1.0b2 → python_homewizard_energy-8.0.0a1}/homewizard_energy/py.typed +0 -0
- {python_homewizard_energy-7.1.0b2 → python_homewizard_energy-8.0.0a1}/homewizard_energy/v1/const.py +0 -0
- {python_homewizard_energy-7.1.0b2 → python_homewizard_energy-8.0.0a1}/homewizard_energy/v2/cacert.py +0 -0
- {python_homewizard_energy-7.1.0b2 → python_homewizard_energy-8.0.0a1}/homewizard_energy/v2/const.py +0 -0
|
@@ -1,6 +1,6 @@
|
|
|
1
1
|
Metadata-Version: 2.1
|
|
2
2
|
Name: python-homewizard-energy
|
|
3
|
-
Version:
|
|
3
|
+
Version: 8.0.0a1
|
|
4
4
|
Summary: Asynchronous Python client for the HomeWizard Energy
|
|
5
5
|
Home-page: https://github.com/homewizard/python-homewizard-energy
|
|
6
6
|
License: Apache-2.0
|
|
@@ -12,9 +12,11 @@ Classifier: Programming Language :: Python :: 3
|
|
|
12
12
|
Classifier: Programming Language :: Python :: 3.12
|
|
13
13
|
Classifier: Programming Language :: Python :: 3.13
|
|
14
14
|
Requires-Dist: aiohttp (>=3.0.0)
|
|
15
|
-
Requires-Dist: async-timeout (>=4.0.3,<
|
|
15
|
+
Requires-Dist: async-timeout (>=4.0.3,<6.0.0)
|
|
16
16
|
Requires-Dist: backoff (>=2.2.1,<3.0.0)
|
|
17
|
+
Requires-Dist: mashumaro (>=3.15,<4.0)
|
|
17
18
|
Requires-Dist: multidict (>=6.0.5,<7.0.0)
|
|
19
|
+
Requires-Dist: orjson (>=3.10.13,<4.0.0)
|
|
18
20
|
Project-URL: Bug Tracker, https://github.com/homewizard/python-homewizard-energy/issues
|
|
19
21
|
Project-URL: Changelog, https://github.com/homewizard/python-homewizard-energy/releases
|
|
20
22
|
Project-URL: Documentation, https://github.com/homewizard/python-homewizard-energy
|
|
@@ -0,0 +1,28 @@
|
|
|
1
|
+
"""Constants for HomeWizard Energy."""
|
|
2
|
+
|
|
3
|
+
import logging
|
|
4
|
+
|
|
5
|
+
LOGGER = logging.getLogger(__name__)
|
|
6
|
+
|
|
7
|
+
MODEL_TO_ID = {
|
|
8
|
+
"HWE-P1": "p1dongle",
|
|
9
|
+
"HWE-SKT": "energysocket",
|
|
10
|
+
"HWE-WTR": "watermeter",
|
|
11
|
+
"HWE-DSP": "display",
|
|
12
|
+
"HWE-KWH1": "energymeter",
|
|
13
|
+
"SDM230-wifi": "energymeter",
|
|
14
|
+
"HWE-KWH3": "energymeter",
|
|
15
|
+
"SDM630-wifi": "energymeter",
|
|
16
|
+
"HWE-BAT": "battery",
|
|
17
|
+
}
|
|
18
|
+
|
|
19
|
+
MODEL_TO_NAME = {
|
|
20
|
+
"HWE-P1": "Wi-Fi P1 Meter",
|
|
21
|
+
"HWE-SKT": "Wi-Fi Energy Socket",
|
|
22
|
+
"HWE-WTR": "Wi-Fi Watermeter",
|
|
23
|
+
"HWE-KWH1": "Wi-Fi kWh Meter 1-phase",
|
|
24
|
+
"HWE-KWH3": "Wi-Fi kWh Meter 3-phase",
|
|
25
|
+
"SDM230-wifi": "Wi-Fi kWh Meter 1-phase",
|
|
26
|
+
"SDM630-wifi": "Wi-Fi kWh Meter 3-phase",
|
|
27
|
+
"HWE-BAT": "Plug-In Battery",
|
|
28
|
+
}
|
|
@@ -0,0 +1,103 @@
|
|
|
1
|
+
"""HomeWizard Energy base class"""
|
|
2
|
+
|
|
3
|
+
from __future__ import annotations
|
|
4
|
+
|
|
5
|
+
from typing import Any
|
|
6
|
+
|
|
7
|
+
from aiohttp.client import ClientSession
|
|
8
|
+
|
|
9
|
+
from .const import LOGGER
|
|
10
|
+
from .models import Device, Measurement, State, StateUpdate, System, SystemUpdate
|
|
11
|
+
|
|
12
|
+
|
|
13
|
+
class HomeWizardEnergy:
|
|
14
|
+
"""Base class for HomeWizard Energy API."""
|
|
15
|
+
|
|
16
|
+
_session: ClientSession | None = None
|
|
17
|
+
_close_session: bool = False
|
|
18
|
+
_request_timeout: int = 10
|
|
19
|
+
_host: str
|
|
20
|
+
|
|
21
|
+
def __init__(
|
|
22
|
+
self,
|
|
23
|
+
host: str,
|
|
24
|
+
clientsession: ClientSession = None,
|
|
25
|
+
timeout: int = 10,
|
|
26
|
+
):
|
|
27
|
+
"""Create a HomeWizard Energy object.
|
|
28
|
+
|
|
29
|
+
Args:
|
|
30
|
+
host: IP or URL for device.
|
|
31
|
+
clientsession: The clientsession.
|
|
32
|
+
timeout: Request timeout in seconds.
|
|
33
|
+
"""
|
|
34
|
+
self._host = host
|
|
35
|
+
self._session = clientsession
|
|
36
|
+
self._close_session = clientsession is None
|
|
37
|
+
self._request_timeout = timeout
|
|
38
|
+
|
|
39
|
+
@property
|
|
40
|
+
def host(self) -> str:
|
|
41
|
+
"""Return the hostname of the device.
|
|
42
|
+
|
|
43
|
+
Returns:
|
|
44
|
+
host: The used host
|
|
45
|
+
|
|
46
|
+
"""
|
|
47
|
+
return self._host
|
|
48
|
+
|
|
49
|
+
async def device(self) -> Device:
|
|
50
|
+
"""Get the device information."""
|
|
51
|
+
raise NotImplementedError
|
|
52
|
+
|
|
53
|
+
async def measurement(self) -> Measurement:
|
|
54
|
+
"""Get the current measurement."""
|
|
55
|
+
raise NotImplementedError
|
|
56
|
+
|
|
57
|
+
async def system(
|
|
58
|
+
self,
|
|
59
|
+
update: SystemUpdate | None = None,
|
|
60
|
+
) -> System:
|
|
61
|
+
"""Get/set the system."""
|
|
62
|
+
raise NotImplementedError
|
|
63
|
+
|
|
64
|
+
async def state(
|
|
65
|
+
self,
|
|
66
|
+
update: StateUpdate | None = None,
|
|
67
|
+
) -> State:
|
|
68
|
+
"""Get/set the state."""
|
|
69
|
+
raise NotImplementedError
|
|
70
|
+
|
|
71
|
+
async def identify(
|
|
72
|
+
self,
|
|
73
|
+
) -> None:
|
|
74
|
+
"""Identify the device."""
|
|
75
|
+
raise NotImplementedError
|
|
76
|
+
|
|
77
|
+
async def reboot(
|
|
78
|
+
self,
|
|
79
|
+
) -> None:
|
|
80
|
+
"""Reboot the device."""
|
|
81
|
+
raise NotImplementedError
|
|
82
|
+
|
|
83
|
+
async def close(self) -> None:
|
|
84
|
+
"""Close client session."""
|
|
85
|
+
LOGGER.debug("Closing clientsession")
|
|
86
|
+
if self._session and self._close_session:
|
|
87
|
+
await self._session.close()
|
|
88
|
+
|
|
89
|
+
async def __aenter__(self) -> HomeWizardEnergy:
|
|
90
|
+
"""Async enter.
|
|
91
|
+
|
|
92
|
+
Returns:
|
|
93
|
+
The HomeWizardEnergy object.
|
|
94
|
+
"""
|
|
95
|
+
return self
|
|
96
|
+
|
|
97
|
+
async def __aexit__(self, *_exc_info: Any) -> None:
|
|
98
|
+
"""Async exit.
|
|
99
|
+
|
|
100
|
+
Args:
|
|
101
|
+
_exc_info: Exec type.
|
|
102
|
+
"""
|
|
103
|
+
await self.close()
|
|
@@ -0,0 +1,485 @@
|
|
|
1
|
+
"""Common models for HomeWizard Energy API."""
|
|
2
|
+
|
|
3
|
+
from __future__ import annotations
|
|
4
|
+
|
|
5
|
+
from dataclasses import dataclass, field
|
|
6
|
+
from datetime import datetime
|
|
7
|
+
from enum import Enum
|
|
8
|
+
from typing import Any
|
|
9
|
+
|
|
10
|
+
from mashumaro.config import BaseConfig
|
|
11
|
+
from mashumaro.exceptions import MissingField
|
|
12
|
+
from mashumaro.mixins.orjson import DataClassORJSONMixin
|
|
13
|
+
|
|
14
|
+
from .const import LOGGER, MODEL_TO_ID, MODEL_TO_NAME
|
|
15
|
+
|
|
16
|
+
|
|
17
|
+
class BaseModel(DataClassORJSONMixin):
|
|
18
|
+
"""Base model for all HomeWizard models."""
|
|
19
|
+
|
|
20
|
+
# pylint: disable-next=too-few-public-methods
|
|
21
|
+
class Config(BaseConfig):
|
|
22
|
+
"""Mashumaro configuration."""
|
|
23
|
+
|
|
24
|
+
serialize_by_alias = True
|
|
25
|
+
omit_none = True
|
|
26
|
+
|
|
27
|
+
|
|
28
|
+
class UpdateBaseModel(BaseModel):
|
|
29
|
+
"""Base model for all 'update' models."""
|
|
30
|
+
|
|
31
|
+
def __post_serialize__(self, d: dict, context: dict | None = None):
|
|
32
|
+
"""Post serialize hook for UpdateBaseModel object."""
|
|
33
|
+
_ = context # Unused
|
|
34
|
+
|
|
35
|
+
if not d:
|
|
36
|
+
raise ValueError("No values to update")
|
|
37
|
+
|
|
38
|
+
return d
|
|
39
|
+
|
|
40
|
+
|
|
41
|
+
def get_verification_hostname(model: str, serial_number: str) -> str:
|
|
42
|
+
"""Helper method to convert device model and serial to identifier
|
|
43
|
+
|
|
44
|
+
The identifier is used to verify the device in the HomeWizard Energy API via HTTPS.
|
|
45
|
+
"""
|
|
46
|
+
|
|
47
|
+
if model not in MODEL_TO_ID:
|
|
48
|
+
raise ValueError(f"Unsupported model: {model}")
|
|
49
|
+
|
|
50
|
+
return f"appliance/{MODEL_TO_ID[model]}/{serial_number}"
|
|
51
|
+
|
|
52
|
+
|
|
53
|
+
@dataclass(kw_only=True)
|
|
54
|
+
class Device(BaseModel):
|
|
55
|
+
"""Represent Device config."""
|
|
56
|
+
|
|
57
|
+
model_name: str | None = None
|
|
58
|
+
id: str | None = None
|
|
59
|
+
|
|
60
|
+
product_name: str = field()
|
|
61
|
+
product_type: str = field()
|
|
62
|
+
serial: str = field()
|
|
63
|
+
api_version: str = field()
|
|
64
|
+
firmware_version: str = field()
|
|
65
|
+
|
|
66
|
+
@classmethod
|
|
67
|
+
def __post_deserialize__(cls, obj: Device) -> Device:
|
|
68
|
+
"""Post deserialize hook for Device object."""
|
|
69
|
+
_ = cls # Unused
|
|
70
|
+
|
|
71
|
+
obj.model_name = MODEL_TO_NAME.get(obj.product_type)
|
|
72
|
+
obj.id = get_verification_hostname(obj.product_type, obj.serial)
|
|
73
|
+
return obj
|
|
74
|
+
|
|
75
|
+
|
|
76
|
+
@dataclass(kw_only=True)
|
|
77
|
+
class Measurement(BaseModel):
|
|
78
|
+
"""Represent Measurement."""
|
|
79
|
+
|
|
80
|
+
# Deprecated, use 'System'
|
|
81
|
+
wifi_ssid: str | None = field(
|
|
82
|
+
default=None,
|
|
83
|
+
)
|
|
84
|
+
wifi_strength: int | None = field(
|
|
85
|
+
default=None,
|
|
86
|
+
)
|
|
87
|
+
|
|
88
|
+
# Generic
|
|
89
|
+
energy_import_kwh: float | None = field(
|
|
90
|
+
default=None,
|
|
91
|
+
)
|
|
92
|
+
energy_import_t1_kwh: float | None = field(
|
|
93
|
+
default=None,
|
|
94
|
+
)
|
|
95
|
+
energy_import_t2_kwh: float | None = field(
|
|
96
|
+
default=None,
|
|
97
|
+
)
|
|
98
|
+
energy_import_t3_kwh: float | None = field(
|
|
99
|
+
default=None,
|
|
100
|
+
)
|
|
101
|
+
energy_import_t4_kwh: float | None = field(
|
|
102
|
+
default=None,
|
|
103
|
+
)
|
|
104
|
+
energy_export_kwh: float | None = field(
|
|
105
|
+
default=None,
|
|
106
|
+
)
|
|
107
|
+
energy_export_t1_kwh: float | None = field(
|
|
108
|
+
default=None,
|
|
109
|
+
)
|
|
110
|
+
energy_export_t2_kwh: float | None = field(
|
|
111
|
+
default=None,
|
|
112
|
+
)
|
|
113
|
+
energy_export_t3_kwh: float | None = field(
|
|
114
|
+
default=None,
|
|
115
|
+
)
|
|
116
|
+
energy_export_t4_kwh: float | None = field(
|
|
117
|
+
default=None,
|
|
118
|
+
)
|
|
119
|
+
|
|
120
|
+
power_w: float | None = field(
|
|
121
|
+
default=None,
|
|
122
|
+
)
|
|
123
|
+
power_l1_w: float | None = field(
|
|
124
|
+
default=None,
|
|
125
|
+
)
|
|
126
|
+
power_l2_w: float | None = field(
|
|
127
|
+
default=None,
|
|
128
|
+
)
|
|
129
|
+
power_l3_w: float | None = field(
|
|
130
|
+
default=None,
|
|
131
|
+
)
|
|
132
|
+
|
|
133
|
+
voltage_v: float | None = field(
|
|
134
|
+
default=None,
|
|
135
|
+
)
|
|
136
|
+
voltage_l1_v: float | None = field(
|
|
137
|
+
default=None,
|
|
138
|
+
)
|
|
139
|
+
voltage_l2_v: float | None = field(
|
|
140
|
+
default=None,
|
|
141
|
+
)
|
|
142
|
+
voltage_l3_v: float | None = field(
|
|
143
|
+
default=None,
|
|
144
|
+
)
|
|
145
|
+
|
|
146
|
+
current_a: float | None = field(
|
|
147
|
+
default=None,
|
|
148
|
+
)
|
|
149
|
+
current_l1_a: float | None = field(
|
|
150
|
+
default=None,
|
|
151
|
+
)
|
|
152
|
+
current_l2_a: float | None = field(
|
|
153
|
+
default=None,
|
|
154
|
+
)
|
|
155
|
+
current_l3_a: float | None = field(
|
|
156
|
+
default=None,
|
|
157
|
+
)
|
|
158
|
+
|
|
159
|
+
apparent_power_va: float | None = field(
|
|
160
|
+
default=None,
|
|
161
|
+
)
|
|
162
|
+
apparent_power_l1_va: float | None = field(
|
|
163
|
+
default=None,
|
|
164
|
+
)
|
|
165
|
+
apparent_power_l2_va: float | None = field(
|
|
166
|
+
default=None,
|
|
167
|
+
)
|
|
168
|
+
apparent_power_l3_va: float | None = field(
|
|
169
|
+
default=None,
|
|
170
|
+
)
|
|
171
|
+
|
|
172
|
+
reactive_power_var: float | None = field(
|
|
173
|
+
default=None,
|
|
174
|
+
)
|
|
175
|
+
reactive_power_l1_var: float | None = field(
|
|
176
|
+
default=None,
|
|
177
|
+
)
|
|
178
|
+
reactive_power_l2_var: float | None = field(
|
|
179
|
+
default=None,
|
|
180
|
+
)
|
|
181
|
+
reactive_power_l3_var: float | None = field(
|
|
182
|
+
default=None,
|
|
183
|
+
)
|
|
184
|
+
|
|
185
|
+
power_factor: float | None = field(
|
|
186
|
+
default=None,
|
|
187
|
+
)
|
|
188
|
+
power_factor_l1: float | None = field(
|
|
189
|
+
default=None,
|
|
190
|
+
)
|
|
191
|
+
power_factor_l2: float | None = field(
|
|
192
|
+
default=None,
|
|
193
|
+
)
|
|
194
|
+
power_factor_l3: float | None = field(
|
|
195
|
+
default=None,
|
|
196
|
+
)
|
|
197
|
+
|
|
198
|
+
frequency_hz: float | None = field(
|
|
199
|
+
default=None,
|
|
200
|
+
)
|
|
201
|
+
|
|
202
|
+
# P1 Meter specific
|
|
203
|
+
timestamp: datetime | None = field(
|
|
204
|
+
default=None,
|
|
205
|
+
metadata={"deserialize": lambda x: Measurement.to_datetime(x)},
|
|
206
|
+
)
|
|
207
|
+
protocol_version: int | None = field(
|
|
208
|
+
default=None,
|
|
209
|
+
)
|
|
210
|
+
meter_model: str | None = field(
|
|
211
|
+
default=None,
|
|
212
|
+
)
|
|
213
|
+
unique_id: str | None = field(
|
|
214
|
+
default=None,
|
|
215
|
+
metadata={"deserialize": lambda x: Measurement.hex_to_readable(x)},
|
|
216
|
+
)
|
|
217
|
+
|
|
218
|
+
tariff: int | None = field(
|
|
219
|
+
default=None,
|
|
220
|
+
)
|
|
221
|
+
|
|
222
|
+
voltage_sag_l1_count: int | None = field(
|
|
223
|
+
default=None,
|
|
224
|
+
)
|
|
225
|
+
voltage_sag_l2_count: int | None = field(
|
|
226
|
+
default=None,
|
|
227
|
+
)
|
|
228
|
+
voltage_sag_l3_count: int | None = field(
|
|
229
|
+
default=None,
|
|
230
|
+
)
|
|
231
|
+
|
|
232
|
+
voltage_swell_l1_count: int | None = field(
|
|
233
|
+
default=None,
|
|
234
|
+
)
|
|
235
|
+
voltage_swell_l2_count: int | None = field(
|
|
236
|
+
default=None,
|
|
237
|
+
)
|
|
238
|
+
voltage_swell_l3_count: int | None = field(
|
|
239
|
+
default=None,
|
|
240
|
+
)
|
|
241
|
+
|
|
242
|
+
any_power_fail_count: int | None = field(
|
|
243
|
+
default=None,
|
|
244
|
+
)
|
|
245
|
+
long_power_fail_count: int | None = field(
|
|
246
|
+
default=None,
|
|
247
|
+
)
|
|
248
|
+
|
|
249
|
+
average_power_15m_w: float | None = field(
|
|
250
|
+
default=None,
|
|
251
|
+
)
|
|
252
|
+
monthly_power_peak_w: float | None = field(
|
|
253
|
+
default=None,
|
|
254
|
+
)
|
|
255
|
+
monthly_power_peak_timestamp: datetime | None = field(
|
|
256
|
+
default=None,
|
|
257
|
+
metadata={"deserialize": lambda x: Measurement.to_datetime(x)},
|
|
258
|
+
)
|
|
259
|
+
|
|
260
|
+
external_devices: dict[str, ExternalDevice] | None = field(
|
|
261
|
+
default=None,
|
|
262
|
+
metadata={
|
|
263
|
+
"alias": "external",
|
|
264
|
+
"deserialize": lambda list: Measurement.array_to_external_device_list(list),
|
|
265
|
+
},
|
|
266
|
+
)
|
|
267
|
+
|
|
268
|
+
# Watermeter Specific
|
|
269
|
+
active_liter_lpm: float | None = field(
|
|
270
|
+
default=None,
|
|
271
|
+
)
|
|
272
|
+
total_liter_m3: float | None = field(
|
|
273
|
+
default=None,
|
|
274
|
+
)
|
|
275
|
+
|
|
276
|
+
# Battery Specific
|
|
277
|
+
cycles: int | None = field(
|
|
278
|
+
default=None,
|
|
279
|
+
)
|
|
280
|
+
state_of_charge_pct: float | None = field(
|
|
281
|
+
default=None,
|
|
282
|
+
)
|
|
283
|
+
|
|
284
|
+
@staticmethod
|
|
285
|
+
def array_to_external_device_list(devices: list[dict]) -> dict[str, ExternalDevice]:
|
|
286
|
+
"""Convert external device dict to list of ExternalDevice objects."""
|
|
287
|
+
rv: dict[str, ExternalDevice] = {}
|
|
288
|
+
|
|
289
|
+
for item in devices:
|
|
290
|
+
try:
|
|
291
|
+
device = ExternalDevice.from_dict(item)
|
|
292
|
+
except MissingField as e:
|
|
293
|
+
LOGGER.error("Error converting external device: %s", e)
|
|
294
|
+
continue
|
|
295
|
+
rv[f"{device.type}_{device.unique_id}"] = device
|
|
296
|
+
|
|
297
|
+
return rv
|
|
298
|
+
|
|
299
|
+
@staticmethod
|
|
300
|
+
def to_datetime(timestamp: str | int | None) -> datetime | None:
|
|
301
|
+
"""Convert DSRM gas-timestamp to datetime object.
|
|
302
|
+
|
|
303
|
+
Args:
|
|
304
|
+
timestamp: Timestamp string, formatted as YYMMDDHHMMSS or YYYY-MM-DDTHH:MM:SS
|
|
305
|
+
|
|
306
|
+
Returns:
|
|
307
|
+
A datetime object.
|
|
308
|
+
"""
|
|
309
|
+
|
|
310
|
+
if timestamp is None:
|
|
311
|
+
return None
|
|
312
|
+
|
|
313
|
+
if isinstance(timestamp, int):
|
|
314
|
+
# V1 API uses int for timestamp
|
|
315
|
+
return datetime.strptime(str(timestamp), "%y%m%d%H%M%S")
|
|
316
|
+
|
|
317
|
+
return datetime.fromisoformat(timestamp)
|
|
318
|
+
|
|
319
|
+
@staticmethod
|
|
320
|
+
def hex_to_readable(value: str | None) -> str | None:
|
|
321
|
+
"""Convert hex string to readable string, if possible.
|
|
322
|
+
|
|
323
|
+
Args:
|
|
324
|
+
value: String to convert, e.g. '4E47475955'
|
|
325
|
+
|
|
326
|
+
Returns:
|
|
327
|
+
A string formatted or original value when failed.
|
|
328
|
+
"""
|
|
329
|
+
try:
|
|
330
|
+
return bytes.fromhex(value).decode("utf-8")
|
|
331
|
+
except (TypeError, ValueError):
|
|
332
|
+
return value
|
|
333
|
+
|
|
334
|
+
@classmethod
|
|
335
|
+
# pylint: disable=too-many-statements
|
|
336
|
+
def __pre_deserialize__(cls, d: dict[Any, Any]) -> dict[Any, Any]:
|
|
337
|
+
_ = cls # Unused
|
|
338
|
+
|
|
339
|
+
if "wifi_ssid" not in d:
|
|
340
|
+
# This is a v2 API response, no need to remap
|
|
341
|
+
return d
|
|
342
|
+
|
|
343
|
+
d["protocol_version"] = d.get("smr_version")
|
|
344
|
+
d["meter_model"] = d.get("meter_model")
|
|
345
|
+
d["unique_id"] = d.get("unique_meter_id")
|
|
346
|
+
d["tariff"] = d.get("active_tariff")
|
|
347
|
+
d["energy_import_kwh"] = d.get(
|
|
348
|
+
"total_power_import_kwh", d.get("total_power_import_t1_kwh")
|
|
349
|
+
)
|
|
350
|
+
d["energy_import_t1_kwh"] = d.get("total_power_import_t1_kwh")
|
|
351
|
+
d["energy_import_t2_kwh"] = d.get("total_power_import_t2_kwh")
|
|
352
|
+
d["energy_import_t3_kwh"] = d.get("total_power_import_t3_kwh")
|
|
353
|
+
d["energy_import_t4_kwh"] = d.get("total_power_import_t4_kwh")
|
|
354
|
+
d["energy_export_kwh"] = d.get(
|
|
355
|
+
"total_power_export_kwh", d.get("total_power_import_t1_kwh")
|
|
356
|
+
)
|
|
357
|
+
d["energy_export_t1_kwh"] = d.get("total_power_export_t1_kwh")
|
|
358
|
+
d["energy_export_t2_kwh"] = d.get("total_power_export_t2_kwh")
|
|
359
|
+
d["energy_export_t3_kwh"] = d.get("total_power_export_t3_kwh")
|
|
360
|
+
d["energy_export_t4_kwh"] = d.get("total_power_export_t4_kwh")
|
|
361
|
+
d["power_w"] = d.get("active_power_w")
|
|
362
|
+
d["power_l1_w"] = d.get("active_power_l1_w")
|
|
363
|
+
d["power_l2_w"] = d.get("active_power_l2_w")
|
|
364
|
+
d["power_l3_w"] = d.get("active_power_l3_w")
|
|
365
|
+
d["voltage_v"] = d.get("active_voltage_v")
|
|
366
|
+
d["voltage_l1_v"] = d.get("active_voltage_l1_v")
|
|
367
|
+
d["voltage_l2_v"] = d.get("active_voltage_l2_v")
|
|
368
|
+
d["voltage_l3_v"] = d.get("active_voltage_l3_v")
|
|
369
|
+
d["current_a"] = d.get("active_current_a")
|
|
370
|
+
d["current_l1_a"] = d.get("active_current_l1_a")
|
|
371
|
+
d["current_l2_a"] = d.get("active_current_l2_a")
|
|
372
|
+
d["current_l3_a"] = d.get("active_current_l3_a")
|
|
373
|
+
d["apparent_power_va"] = d.get("active_apparent_power_va")
|
|
374
|
+
d["apparent_power_l1_va"] = d.get("active_apparent_power_l1_va")
|
|
375
|
+
d["apparent_power_l2_va"] = d.get("active_apparent_power_l2_va")
|
|
376
|
+
d["apparent_power_l3_va"] = d.get("active_apparent_power_l3_va")
|
|
377
|
+
d["reactive_power_var"] = d.get("active_reactive_power_var")
|
|
378
|
+
d["reactive_power_l1_var"] = d.get("active_reactive_power_l1_var")
|
|
379
|
+
d["reactive_power_l2_var"] = d.get("active_reactive_power_l2_var")
|
|
380
|
+
d["reactive_power_l3_var"] = d.get("active_reactive_power_l3_var")
|
|
381
|
+
d["power_factor"] = d.get("active_power_factor")
|
|
382
|
+
d["power_factor_l1"] = d.get("active_power_factor_l1")
|
|
383
|
+
d["power_factor_l2"] = d.get("active_power_factor_l2")
|
|
384
|
+
d["power_factor_l3"] = d.get("active_power_factor_l3")
|
|
385
|
+
d["frequency_hz"] = d.get("active_frequency_hz")
|
|
386
|
+
d["voltage_sag_l1_count"] = d.get("voltage_sag_l1_count")
|
|
387
|
+
d["voltage_sag_l2_count"] = d.get("voltage_sag_l2_count")
|
|
388
|
+
d["voltage_sag_l3_count"] = d.get("voltage_sag_l3_count")
|
|
389
|
+
d["voltage_swell_l1_count"] = d.get("voltage_swell_l1_count")
|
|
390
|
+
d["voltage_swell_l2_count"] = d.get("voltage_swell_l2_count")
|
|
391
|
+
d["voltage_swell_l3_count"] = d.get("voltage_swell_l3_count")
|
|
392
|
+
d["any_power_fail_count"] = d.get("any_power_fail_count")
|
|
393
|
+
d["long_power_fail_count"] = d.get("long_power_fail_count")
|
|
394
|
+
d["average_power_15m_w"] = d.get("active_power_average_w")
|
|
395
|
+
d["monthly_power_peak_w"] = d.get("montly_power_peak_w")
|
|
396
|
+
d["monthly_power_peak_timestamp"] = d.get("montly_power_peak_timestamp")
|
|
397
|
+
d["active_liter_lpm"] = d.get("active_liter_lpm")
|
|
398
|
+
d["total_liter_m3"] = d.get("total_liter_m3")
|
|
399
|
+
d["external_devices"] = d.get("external_devices")
|
|
400
|
+
|
|
401
|
+
return d
|
|
402
|
+
|
|
403
|
+
|
|
404
|
+
@dataclass
|
|
405
|
+
class ExternalDevice(BaseModel):
|
|
406
|
+
"""Represents externally connected device."""
|
|
407
|
+
|
|
408
|
+
class DeviceType(Enum):
|
|
409
|
+
"""Device type allocations."""
|
|
410
|
+
|
|
411
|
+
GAS_METER = "gas_meter"
|
|
412
|
+
HEAT_METER = "heat_meter"
|
|
413
|
+
WARM_WATER_METER = "warm_water_meter"
|
|
414
|
+
WATER_METER = "water_meter"
|
|
415
|
+
INLET_HEAT_METER = "inlet_heat_meter"
|
|
416
|
+
|
|
417
|
+
unique_id: datetime = field(
|
|
418
|
+
default=None, metadata={"deserialize": lambda x: Measurement.hex_to_readable(x)}
|
|
419
|
+
)
|
|
420
|
+
|
|
421
|
+
type: DeviceType | None = field(
|
|
422
|
+
default=None,
|
|
423
|
+
metadata={
|
|
424
|
+
"deserialize": lambda x: ExternalDevice.DeviceType(x)
|
|
425
|
+
if x in ExternalDevice.DeviceType.__members__.values()
|
|
426
|
+
else None
|
|
427
|
+
},
|
|
428
|
+
)
|
|
429
|
+
value: float = field(default=0.0)
|
|
430
|
+
unit: str = field(default="")
|
|
431
|
+
timestamp: datetime = field(
|
|
432
|
+
default=None, metadata={"deserialize": lambda x: Measurement.to_datetime(x)}
|
|
433
|
+
)
|
|
434
|
+
|
|
435
|
+
|
|
436
|
+
@dataclass(kw_only=True)
|
|
437
|
+
class StateUpdate(UpdateBaseModel):
|
|
438
|
+
"""Represent State update config."""
|
|
439
|
+
|
|
440
|
+
power_on: bool | None = field(default=None)
|
|
441
|
+
switch_lock: bool | None = field(default=None)
|
|
442
|
+
brightness: int | None = field(default=None)
|
|
443
|
+
|
|
444
|
+
|
|
445
|
+
@dataclass(kw_only=True)
|
|
446
|
+
class State(BaseModel):
|
|
447
|
+
"""Represent current state."""
|
|
448
|
+
|
|
449
|
+
power_on: bool | None = field(
|
|
450
|
+
default=None,
|
|
451
|
+
)
|
|
452
|
+
switch_lock: bool | None = field(
|
|
453
|
+
default=None,
|
|
454
|
+
)
|
|
455
|
+
brightness: int | None = field(
|
|
456
|
+
default=None,
|
|
457
|
+
)
|
|
458
|
+
|
|
459
|
+
|
|
460
|
+
@dataclass
|
|
461
|
+
class SystemUpdate(UpdateBaseModel):
|
|
462
|
+
"""Represent System update config."""
|
|
463
|
+
|
|
464
|
+
cloud_enabled: bool | None = field(default=None)
|
|
465
|
+
status_led_brightness_pct: int | None = field(default=None)
|
|
466
|
+
api_v1_enabled: bool | None = field(default=None)
|
|
467
|
+
|
|
468
|
+
|
|
469
|
+
@dataclass(kw_only=True)
|
|
470
|
+
class System(BaseModel):
|
|
471
|
+
"""Represent System config."""
|
|
472
|
+
|
|
473
|
+
wifi_ssid: str | None = field(default=None)
|
|
474
|
+
wifi_rssi_db: int | None = field(default=None)
|
|
475
|
+
cloud_enabled: bool | None = field(default=None)
|
|
476
|
+
uptime_s: int | None = field(default=None)
|
|
477
|
+
status_led_brightness_pct: int | None = field(default=None)
|
|
478
|
+
api_v1_enabled: bool | None = field(default=None)
|
|
479
|
+
|
|
480
|
+
|
|
481
|
+
@dataclass(kw_only=True)
|
|
482
|
+
class Token(BaseModel):
|
|
483
|
+
"""Represent Token."""
|
|
484
|
+
|
|
485
|
+
token: str = field()
|