pyfieldbridge 0.1.0__tar.gz
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- pyfieldbridge-0.1.0/LICENSE +21 -0
- pyfieldbridge-0.1.0/PKG-INFO +359 -0
- pyfieldbridge-0.1.0/README.md +325 -0
- pyfieldbridge-0.1.0/fieldbridge/__init__.py +93 -0
- pyfieldbridge-0.1.0/fieldbridge/adapters/__init__.py +1 -0
- pyfieldbridge-0.1.0/fieldbridge/adapters/can.py +30 -0
- pyfieldbridge-0.1.0/fieldbridge/adapters/ethercat.py +15 -0
- pyfieldbridge-0.1.0/fieldbridge/adapters/ethernet.py +18 -0
- pyfieldbridge-0.1.0/fieldbridge/adapters/flexray.py +18 -0
- pyfieldbridge-0.1.0/fieldbridge/adapters/index.py +56 -0
- pyfieldbridge-0.1.0/fieldbridge/adapters/lin.py +17 -0
- pyfieldbridge-0.1.0/fieldbridge/adapters/modbus.py +30 -0
- pyfieldbridge-0.1.0/fieldbridge/adapters/profibus_dp.py +4 -0
- pyfieldbridge-0.1.0/fieldbridge/adapters/profibus_pa.py +17 -0
- pyfieldbridge-0.1.0/fieldbridge/adapters/profinet.py +18 -0
- pyfieldbridge-0.1.0/fieldbridge/adapters/rules.py +22 -0
- pyfieldbridge-0.1.0/fieldbridge/core/__init__.py +6 -0
- pyfieldbridge-0.1.0/fieldbridge/core/adapter.py +79 -0
- pyfieldbridge-0.1.0/fieldbridge/core/convert.py +384 -0
- pyfieldbridge-0.1.0/fieldbridge/core/errors.py +50 -0
- pyfieldbridge-0.1.0/fieldbridge/core/result.py +19 -0
- pyfieldbridge-0.1.0/fieldbridge/core/types.py +186 -0
- pyfieldbridge-0.1.0/fieldbridge/core/validation.py +100 -0
- pyfieldbridge-0.1.0/fieldbridge/py.typed +0 -0
- pyfieldbridge-0.1.0/fieldbridge/wire/__init__.py +33 -0
- pyfieldbridge-0.1.0/fieldbridge/wire/bytes.py +99 -0
- pyfieldbridge-0.1.0/fieldbridge/wire/can.py +262 -0
- pyfieldbridge-0.1.0/fieldbridge/wire/ethernet.py +327 -0
- pyfieldbridge-0.1.0/fieldbridge/wire/index.py +97 -0
- pyfieldbridge-0.1.0/fieldbridge/wire/modbus.py +116 -0
- pyfieldbridge-0.1.0/pyfieldbridge/__init__.py +4 -0
- pyfieldbridge-0.1.0/pyfieldbridge/py.typed +0 -0
- pyfieldbridge-0.1.0/pyfieldbridge/wire.py +1 -0
- pyfieldbridge-0.1.0/pyfieldbridge.egg-info/PKG-INFO +359 -0
- pyfieldbridge-0.1.0/pyfieldbridge.egg-info/SOURCES.txt +41 -0
- pyfieldbridge-0.1.0/pyfieldbridge.egg-info/dependency_links.txt +1 -0
- pyfieldbridge-0.1.0/pyfieldbridge.egg-info/requires.txt +7 -0
- pyfieldbridge-0.1.0/pyfieldbridge.egg-info/top_level.txt +2 -0
- pyfieldbridge-0.1.0/pyproject.toml +53 -0
- pyfieldbridge-0.1.0/setup.cfg +4 -0
- pyfieldbridge-0.1.0/tests/test_conversion.py +111 -0
- pyfieldbridge-0.1.0/tests/test_cross_language_parity.py +218 -0
- pyfieldbridge-0.1.0/tests/test_wire.py +86 -0
|
@@ -0,0 +1,21 @@
|
|
|
1
|
+
MIT License
|
|
2
|
+
|
|
3
|
+
Copyright (c) 2026 Mohamed Mahmoud
|
|
4
|
+
|
|
5
|
+
Permission is hereby granted, free of charge, to any person obtaining a copy
|
|
6
|
+
of this software and associated documentation files (the "Software"), to deal
|
|
7
|
+
in the Software without restriction, including without limitation the rights
|
|
8
|
+
to use, copy, modify, merge, publish, distribute, sublicense, and/or sell
|
|
9
|
+
copies of the Software, and to permit persons to whom the Software is
|
|
10
|
+
furnished to do so, subject to the following conditions:
|
|
11
|
+
|
|
12
|
+
The above copyright notice and this permission notice shall be included in all
|
|
13
|
+
copies or substantial portions of the Software.
|
|
14
|
+
|
|
15
|
+
THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR
|
|
16
|
+
IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY,
|
|
17
|
+
FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE
|
|
18
|
+
AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER
|
|
19
|
+
LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM,
|
|
20
|
+
OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE
|
|
21
|
+
SOFTWARE.
|
|
@@ -0,0 +1,359 @@
|
|
|
1
|
+
Metadata-Version: 2.4
|
|
2
|
+
Name: pyfieldbridge
|
|
3
|
+
Version: 0.1.0
|
|
4
|
+
Summary: Python conversion for industrial and automotive fieldbus frame envelopes
|
|
5
|
+
Author-email: Mohamed Mahmoud <imohamed.abdelhamed@gmail.com>
|
|
6
|
+
License: MIT
|
|
7
|
+
Project-URL: Homepage, https://github.com/MAbdelhamid-Admin/PyfieldBridge
|
|
8
|
+
Project-URL: Repository, https://github.com/MAbdelhamid-Admin/PyfieldBridge
|
|
9
|
+
Project-URL: Issues, https://github.com/MAbdelhamid-Admin/PyfieldBridge/issues
|
|
10
|
+
Project-URL: Node.js / TypeScript version, https://github.com/MAbdelhamid-Admin/fieldBridge
|
|
11
|
+
Project-URL: Documentation, https://mabdelhamid-admin.github.io/PyfieldBridge/
|
|
12
|
+
Keywords: industrial,fieldbus,protocol,converter,gateway,modbus,profibus,profinet,ethercat,can,can-fd,lin,flexray
|
|
13
|
+
Classifier: Development Status :: 3 - Alpha
|
|
14
|
+
Classifier: Intended Audience :: Developers
|
|
15
|
+
Classifier: License :: OSI Approved :: MIT License
|
|
16
|
+
Classifier: Programming Language :: Python :: 3
|
|
17
|
+
Classifier: Programming Language :: Python :: 3 :: Only
|
|
18
|
+
Classifier: Programming Language :: Python :: 3.10
|
|
19
|
+
Classifier: Programming Language :: Python :: 3.11
|
|
20
|
+
Classifier: Programming Language :: Python :: 3.12
|
|
21
|
+
Classifier: Programming Language :: Python :: 3.13
|
|
22
|
+
Classifier: Topic :: Software Development :: Libraries
|
|
23
|
+
Classifier: Topic :: System :: Networking
|
|
24
|
+
Classifier: Typing :: Typed
|
|
25
|
+
Requires-Python: >=3.10
|
|
26
|
+
Description-Content-Type: text/markdown
|
|
27
|
+
License-File: LICENSE
|
|
28
|
+
Provides-Extra: docs
|
|
29
|
+
Requires-Dist: pdoc>=15; extra == "docs"
|
|
30
|
+
Provides-Extra: dev
|
|
31
|
+
Requires-Dist: pytest>=8; extra == "dev"
|
|
32
|
+
Requires-Dist: pdoc>=15; extra == "dev"
|
|
33
|
+
Dynamic: license-file
|
|
34
|
+
|
|
35
|
+
# PyfieldBridge
|
|
36
|
+
|
|
37
|
+
[](https://github.com/MAbdelhamid-Admin/PyfieldBridge/actions/workflows/ci.yml)
|
|
38
|
+
[](https://mabdelhamid-admin.github.io/PyfieldBridge/)
|
|
39
|
+
[](https://www.python.org/)
|
|
40
|
+
[](LICENSE)
|
|
41
|
+
|
|
42
|
+
Validated conversion of **frame envelopes** between industrial and automotive
|
|
43
|
+
protocols in Python: Ethernet, PROFINET, PROFIBUS DP/PA, Modbus RTU/TCP,
|
|
44
|
+
CAN / CAN FD, LIN, FlexRay and EtherCAT.
|
|
45
|
+
|
|
46
|
+
- Strict validation against each protocol's limits on both encode and decode
|
|
47
|
+
- Payload bytes are preserved exactly; nothing is silently guessed
|
|
48
|
+
- Device IDs bridge message-addressed buses (CAN, LIN) and device-addressed
|
|
49
|
+
buses (Modbus, PROFIBUS, EtherCAT)
|
|
50
|
+
- Parse and serialize real wire bytes: Modbus TCP/RTU, SocketCAN and candump,
|
|
51
|
+
Ethernet, PROFINET RT, EtherCAT
|
|
52
|
+
- Typed `FieldbridgeError` exceptions with stable codes, plus a non-throwing
|
|
53
|
+
`try_*` API
|
|
54
|
+
- No runtime dependencies; Python 3.10+
|
|
55
|
+
|
|
56
|
+
Using Node.js or TypeScript? See the [`fieldbridge`](https://github.com/MAbdelhamid-Admin/fieldBridge)
|
|
57
|
+
package for the same protocol model on that platform.
|
|
58
|
+
|
|
59
|
+
**Documentation:** https://mabdelhamid-admin.github.io/PyfieldBridge/
|
|
60
|
+
|
|
61
|
+
## Install
|
|
62
|
+
|
|
63
|
+
From PyPI:
|
|
64
|
+
|
|
65
|
+
```bash
|
|
66
|
+
python -m pip install pyfieldbridge
|
|
67
|
+
```
|
|
68
|
+
|
|
69
|
+
From a checkout:
|
|
70
|
+
|
|
71
|
+
```bash
|
|
72
|
+
python -m pip install -e .
|
|
73
|
+
```
|
|
74
|
+
|
|
75
|
+
The import package is `fieldbridge`; `pyfieldbridge` is provided as a
|
|
76
|
+
compatibility package name.
|
|
77
|
+
|
|
78
|
+
## Quick start
|
|
79
|
+
|
|
80
|
+
```python
|
|
81
|
+
from fieldbridge import convert_message
|
|
82
|
+
|
|
83
|
+
result = convert_message({
|
|
84
|
+
"source": {
|
|
85
|
+
"device_id": 17,
|
|
86
|
+
"message": {"protocol": "can", "identifier": 0x123, "payload": [3, 0, 10]},
|
|
87
|
+
},
|
|
88
|
+
"target": {"protocol": "modbus-rtu"},
|
|
89
|
+
})
|
|
90
|
+
|
|
91
|
+
result.message
|
|
92
|
+
# {'protocol': 'modbus-rtu', 'address': 17, 'device_id': 17, 'payload': [3, 0, 10]}
|
|
93
|
+
result.warnings
|
|
94
|
+
# explains what was inferred, overridden or dropped
|
|
95
|
+
```
|
|
96
|
+
|
|
97
|
+
Every conversion returns `warnings` describing anything that was inferred,
|
|
98
|
+
overridden or dropped. Log them; they are how you learn what changed.
|
|
99
|
+
|
|
100
|
+
## Scope and limitations
|
|
101
|
+
|
|
102
|
+
PyfieldBridge converts the **envelope** (addresses, identifiers, payload
|
|
103
|
+
limits, metadata) and preserves payload bytes. It does **not** perform
|
|
104
|
+
semantic, bit-level translation: process images, device profiles, cycle
|
|
105
|
+
timing, safety semantics, endianness and vendor-specific mappings cannot be
|
|
106
|
+
inferred safely from an arbitrary frame. Applications that know those details
|
|
107
|
+
can use a `signals` mapping or supply their own adapter.
|
|
108
|
+
|
|
109
|
+
## API
|
|
110
|
+
|
|
111
|
+
### `convert_frame({ source, target_protocol, options? })`
|
|
112
|
+
|
|
113
|
+
Converts a single frame.
|
|
114
|
+
|
|
115
|
+
```python
|
|
116
|
+
from fieldbridge import convert_frame
|
|
117
|
+
|
|
118
|
+
result = convert_frame({
|
|
119
|
+
"source": {"protocol": "ethernet", "payload": [1], "signals": {"speed": 42}},
|
|
120
|
+
"target_protocol": "ethercat",
|
|
121
|
+
"options": {
|
|
122
|
+
"mapping": {"speed": "velocity"}, # rename/select signals; unlisted ones are dropped
|
|
123
|
+
"metadata": {"cycle": "1ms"}, # metadata for the target frame
|
|
124
|
+
"target_device_id": 3, # target device if the frame has no address
|
|
125
|
+
},
|
|
126
|
+
})
|
|
127
|
+
|
|
128
|
+
result.frame
|
|
129
|
+
result.warnings
|
|
130
|
+
```
|
|
131
|
+
|
|
132
|
+
### `convert_message({ source, target, options? })`
|
|
133
|
+
|
|
134
|
+
Converts a message that comes with a device identity and context.
|
|
135
|
+
|
|
136
|
+
```python
|
|
137
|
+
from fieldbridge import convert_message
|
|
138
|
+
|
|
139
|
+
convert_message({
|
|
140
|
+
"source": {
|
|
141
|
+
"device_id": "gateway-1",
|
|
142
|
+
"context": {"line": "A"},
|
|
143
|
+
"message": {"protocol": "can", "identifier": 0x12, "payload": [1, 2]},
|
|
144
|
+
},
|
|
145
|
+
"target": {
|
|
146
|
+
"protocol": "lin",
|
|
147
|
+
"context": {"schedule": "body-controller-10ms"},
|
|
148
|
+
},
|
|
149
|
+
})
|
|
150
|
+
```
|
|
151
|
+
|
|
152
|
+
- `source.device_id` identifies the source device.
|
|
153
|
+
- `source.context` holds extra facts about the source, used as defaults for the
|
|
154
|
+
message metadata.
|
|
155
|
+
- `target.device_id` is the device to address on the target bus.
|
|
156
|
+
- `target.context` holds target-specific fields (schedule, slot, profile…). If
|
|
157
|
+
an adapter declares required context keys, they must appear here; a missing
|
|
158
|
+
key fails the conversion instead of being guessed.
|
|
159
|
+
|
|
160
|
+
### Non-throwing API
|
|
161
|
+
|
|
162
|
+
```python
|
|
163
|
+
from fieldbridge import try_convert_message
|
|
164
|
+
|
|
165
|
+
result = try_convert_message(request)
|
|
166
|
+
if result.ok:
|
|
167
|
+
send(result.value.message)
|
|
168
|
+
else:
|
|
169
|
+
print(result.error.code, result.error) # e.g. "INVALID_DEVICE_ID"
|
|
170
|
+
```
|
|
171
|
+
|
|
172
|
+
The `try_*` functions never raise. Errors raised inside a custom adapter are
|
|
173
|
+
wrapped with code `INTERNAL`, and the original exception is kept in `cause`.
|
|
174
|
+
|
|
175
|
+
### Errors
|
|
176
|
+
|
|
177
|
+
The throwing functions only raise `FieldbridgeError`, which has a stable `code`
|
|
178
|
+
and, where relevant, `protocol` and `field`. Branch on `code`, not on the
|
|
179
|
+
message text.
|
|
180
|
+
|
|
181
|
+
| Code | Meaning |
|
|
182
|
+
| --- | --- |
|
|
183
|
+
| `UNSUPPORTED_PROTOCOL` | Unknown protocol name |
|
|
184
|
+
| `INVALID_FRAME` | Input is not a valid frame/request object |
|
|
185
|
+
| `PROTOCOL_MISMATCH` | Frame given to the adapter of a different protocol |
|
|
186
|
+
| `INVALID_PAYLOAD` | Non-byte values or a protocol length rule violated |
|
|
187
|
+
| `PAYLOAD_TOO_LARGE` | Payload exceeds the protocol maximum |
|
|
188
|
+
| `MISSING_FIELD` | A required field (e.g. CAN identifier, Modbus address) is absent |
|
|
189
|
+
| `INVALID_FIELD` | A field is out of range |
|
|
190
|
+
| `MISSING_CONTEXT` | A required target context key is absent |
|
|
191
|
+
| `INVALID_DEVICE_ID` | A device ID cannot be used as a bus address |
|
|
192
|
+
| `CHECKSUM_MISMATCH` | A wire frame's checksum (Modbus RTU CRC) is wrong |
|
|
193
|
+
| `UNSUPPORTED_FEATURE` | Valid input that PyfieldBridge doesn't support yet (e.g. CAN error frames) |
|
|
194
|
+
| `INTERNAL` | Error raised by a custom adapter (`try_*` API only) |
|
|
195
|
+
|
|
196
|
+
### Custom adapters
|
|
197
|
+
|
|
198
|
+
The built-in `adapters` registry is frozen. To add or replace adapters, create
|
|
199
|
+
your own converter; nothing global is modified.
|
|
200
|
+
|
|
201
|
+
```python
|
|
202
|
+
from fieldbridge import create_adapter, create_converter
|
|
203
|
+
|
|
204
|
+
converter = create_converter({
|
|
205
|
+
"adapters": {
|
|
206
|
+
"ethercat": create_adapter({
|
|
207
|
+
"protocol": "ethercat",
|
|
208
|
+
"max_payload": 1486,
|
|
209
|
+
"fields": ["address"],
|
|
210
|
+
"uses_device_address": True,
|
|
211
|
+
"required_context": ["profile"],
|
|
212
|
+
"validate": lambda frame: None, # raise FieldbridgeError on violations
|
|
213
|
+
}),
|
|
214
|
+
},
|
|
215
|
+
})
|
|
216
|
+
|
|
217
|
+
converter.convert_message(request)
|
|
218
|
+
converter.try_convert_frame(request)
|
|
219
|
+
```
|
|
220
|
+
|
|
221
|
+
## Wire formats
|
|
222
|
+
|
|
223
|
+
The main API works on parsed frames. The `fieldbridge.wire` module turns raw
|
|
224
|
+
bytes into those frames and back. Parsing checks lengths, checksums, header
|
|
225
|
+
fields, and the protocol rules enforced by the adapters.
|
|
226
|
+
|
|
227
|
+
```python
|
|
228
|
+
from fieldbridge import convert_frame
|
|
229
|
+
from fieldbridge.wire import parse, serialize
|
|
230
|
+
|
|
231
|
+
# Modbus RTU -> Modbus TCP gateway
|
|
232
|
+
[rtu] = parse("modbus-rtu", rtu_bytes) # CRC is verified
|
|
233
|
+
result = convert_frame({
|
|
234
|
+
"source": rtu,
|
|
235
|
+
"target_protocol": "modbus-tcp",
|
|
236
|
+
"options": {"metadata": {"transactionId": 1}},
|
|
237
|
+
})
|
|
238
|
+
socket.send(serialize(result.frame)) # MBAP header is built for you
|
|
239
|
+
```
|
|
240
|
+
|
|
241
|
+
`parse(protocol, bytes)` always returns a **list** of frames, because one
|
|
242
|
+
Modbus TCP buffer can hold several ADUs and one EtherCAT frame several
|
|
243
|
+
datagrams. `serialize(frame)` returns `bytes`.
|
|
244
|
+
|
|
245
|
+
| Protocol | Functions | Format | Frame mapping |
|
|
246
|
+
| --- | --- | --- | --- |
|
|
247
|
+
| Modbus TCP | `parse_modbus_tcp`, `parse_modbus_tcp_stream`, `serialize_modbus_tcp` | MBAP header + PDU | `address` = unit id, `payload` = PDU, `metadata.transactionId` |
|
|
248
|
+
| Modbus RTU | `parse_modbus_rtu`, `serialize_modbus_rtu`, `crc16_modbus` | address + PDU + CRC-16 | `address` = slave, `payload` = PDU |
|
|
249
|
+
| CAN / CAN FD | `parse_socket_can`, `serialize_socket_can` | Linux `struct can_frame` (16 B) / `canfd_frame` (72 B) | `identifier`, `metadata.extended / fd / brs / esi / rtr` |
|
|
250
|
+
| CAN / CAN FD | `parse_candump_line`, `format_candump_line` | can-utils `candump` text: log format (`123#DEADBEEF`) and default display format (`can0 123 [4] DE AD BE EF`) | as above, plus `metadata.timestamp / interface` |
|
|
251
|
+
| Ethernet | `parse_ethernet`, `serialize_ethernet` | Ethernet II / 802.3, optional 802.1Q | MACs in `destination_address` / `source_address`, `identifier` = EtherType, `metadata.vlanId / vlanPriority` |
|
|
252
|
+
| PROFINET RT | `parse_profinet`, `serialize_profinet` | EtherType 0x8892 | `identifier` = FrameID, `payload` = IO data + APDU status |
|
|
253
|
+
| EtherCAT | `parse_ethercat`, `serialize_ethercat` | EtherType 0x88A4, one frame per datagram | `metadata.command / index / offset / workingCounter`; `address` for configured (FPxx) commands, `metadata.position` for auto-increment, `metadata.adp` for broadcast, `metadata.logicalAddress` for logical commands |
|
|
254
|
+
|
|
255
|
+
`parse_ethernet_auto(bytes)` detects PROFINET and EtherCAT from the EtherType.
|
|
256
|
+
For a TCP connection, feed each chunk to `parse_modbus_tcp_stream`, which
|
|
257
|
+
returns the complete ADUs plus a `rest` to prepend to the next chunk.
|
|
258
|
+
|
|
259
|
+
Notes:
|
|
260
|
+
|
|
261
|
+
- Ethernet frames are read and written **without the FCS**, which is how most
|
|
262
|
+
capture tools deliver them. Serialized frames are zero-padded to 60 bytes.
|
|
263
|
+
- Modbus RTU parsing expects **one complete frame**. Splitting a raw serial
|
|
264
|
+
stream (by inter-frame silence) is up to your transport layer.
|
|
265
|
+
- LIN, FlexRay and PROFIBUS wire formats depend on the interface hardware and
|
|
266
|
+
are not implemented yet. For those protocols `parse` / `serialize` raise
|
|
267
|
+
`UNSUPPORTED_FEATURE`. `wire_protocols` lists the supported ones.
|
|
268
|
+
|
|
269
|
+
## Conversion rules
|
|
270
|
+
|
|
271
|
+
### Device IDs and bus addresses
|
|
272
|
+
|
|
273
|
+
Some buses address *devices* (Modbus slave/unit id, PROFIBUS station,
|
|
274
|
+
EtherCAT station). Others only address *messages* (CAN, LIN, FlexRay
|
|
275
|
+
identifiers). `device_id` connects the two:
|
|
276
|
+
|
|
277
|
+
- **To a device-addressed bus**, the target `address` is the first available
|
|
278
|
+
of:
|
|
279
|
+
1. the `address` in the message
|
|
280
|
+
2. `target.device_id` (or `options.target_device_id`)
|
|
281
|
+
3. the source `device_id`
|
|
282
|
+
|
|
283
|
+
A numeric `device_id`, or a string like `"17"` or `"0x11"`, is used as the
|
|
284
|
+
address. A name such as `"gateway-1"` is rejected with `INVALID_DEVICE_ID`
|
|
285
|
+
instead of being guessed. The result is then checked against the target's
|
|
286
|
+
address range.
|
|
287
|
+
- **From a device-addressed bus**, the source `address` becomes the result's
|
|
288
|
+
`device_id` when none was given.
|
|
289
|
+
|
|
290
|
+
### Conflicts: the message wins
|
|
291
|
+
|
|
292
|
+
When the message and the surrounding request disagree, **the value in the
|
|
293
|
+
message is used**, and a warning is added:
|
|
294
|
+
|
|
295
|
+
| Conflict | Used |
|
|
296
|
+
| --- | --- |
|
|
297
|
+
| `message.address` vs `target.device_id` | `message.address` |
|
|
298
|
+
| `message.device_id` vs `source.device_id` | `message.device_id` |
|
|
299
|
+
| `message.metadata` vs `source.context` | `message.metadata` |
|
|
300
|
+
|
|
301
|
+
`target.context` and `options.metadata` are instructions for the target, not
|
|
302
|
+
facts about the source, so they set the target frame's metadata. Any message
|
|
303
|
+
value they override is also reported in the warnings.
|
|
304
|
+
|
|
305
|
+
### Envelope fields
|
|
306
|
+
|
|
307
|
+
Each protocol declares which envelope fields it uses. A field the target
|
|
308
|
+
protocol doesn't use is dropped from the result and listed in the warnings.
|
|
309
|
+
For example, a CAN `identifier` has no meaning on Modbus.
|
|
310
|
+
|
|
311
|
+
| Protocol | Fields used | Payload limit | Other rules |
|
|
312
|
+
| --- | --- | --- | --- |
|
|
313
|
+
| Ethernet | `source_address`, `destination_address` (MAC), `identifier` (EtherType) | 1500 bytes | MAC ≤ 48 bits, EtherType ≤ 0xFFFF |
|
|
314
|
+
| PROFINET | `source_address`, `destination_address` (MAC), `identifier` (FrameID) | 1498 bytes (cyclic IO data 40..1440 + status) | FrameID ≤ 0xFFFF |
|
|
315
|
+
| PROFIBUS DP / PA | `address` (destination station), `source_address` | 244 bytes | station addresses 0..127 |
|
|
316
|
+
| Modbus RTU | `address` | 253-byte PDU | address 0..247 required, valid function code |
|
|
317
|
+
| Modbus TCP | `address` (unit id) | 253-byte PDU | unit id 0..255 required, valid function code |
|
|
318
|
+
| CAN | `identifier` | 8 bytes classic; CAN FD DLC lengths up to 64 | identifier required; `metadata.extended` / `metadata.fd` flags, inferred when unambiguous |
|
|
319
|
+
| LIN | `identifier` | 1..8 bytes | 6-bit identifier required |
|
|
320
|
+
| FlexRay | `identifier` (slot) | 0..254 bytes, even length | slot 1..2047 required |
|
|
321
|
+
| EtherCAT | `address` (station) | 1486 bytes | station address ≤ 0xFFFF |
|
|
322
|
+
|
|
323
|
+
For Modbus, `payload` is the PDU (function code followed by data). The address
|
|
324
|
+
byte, MBAP header and CRC are not part of it.
|
|
325
|
+
|
|
326
|
+
## Development
|
|
327
|
+
|
|
328
|
+
```bash
|
|
329
|
+
python -m pip install -e . pytest
|
|
330
|
+
python -m pytest
|
|
331
|
+
```
|
|
332
|
+
|
|
333
|
+
Build the documentation site locally:
|
|
334
|
+
|
|
335
|
+
```bash
|
|
336
|
+
python -m pip install -e . "pdoc>=15"
|
|
337
|
+
pdoc -o site fieldbridge fieldbridge.wire pyfieldbridge pyfieldbridge.wire
|
|
338
|
+
```
|
|
339
|
+
|
|
340
|
+
Project layout:
|
|
341
|
+
|
|
342
|
+
```
|
|
343
|
+
fieldbridge/
|
|
344
|
+
__init__.py public API
|
|
345
|
+
core/ types, errors, validation, conversion engine, result helpers
|
|
346
|
+
adapters/ one adapter per protocol + shared rule helpers
|
|
347
|
+
wire/ byte-level parse/serialize
|
|
348
|
+
index.py generic parse()/serialize() + re-exports
|
|
349
|
+
bytes.py shared byte helpers
|
|
350
|
+
modbus.py Modbus TCP / RTU
|
|
351
|
+
can.py SocketCAN binary, candump text
|
|
352
|
+
ethernet.py Ethernet, PROFINET RT, EtherCAT
|
|
353
|
+
pyfieldbridge/ compatibility package name
|
|
354
|
+
tests/ conversion, wire and differential tests
|
|
355
|
+
```
|
|
356
|
+
|
|
357
|
+
## License
|
|
358
|
+
|
|
359
|
+
[MIT](LICENSE)
|