labware 0.2.4__tar.gz → 0.2.6__tar.gz
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- {labware-0.2.4 → labware-0.2.6}/PKG-INFO +1 -1
- {labware-0.2.4 → labware-0.2.6}/labware/_static_version.py +1 -1
- labware-0.2.6/labware/definitions/Ramona_Xona_chip_holder_3_well_plate.json +60 -0
- labware-0.2.6/labware/definitions/Ramona_Xona_chip_holder_4_well_plate.json +60 -0
- labware-0.2.6/labware/definitions/Watson_196-96FIS_96_well_plate.json +46 -0
- labware-0.2.6/labware/definitions/Xona_XC-SF150-X4_in_Ramona_chip_holder_12_well_plate.json +73 -0
- labware-0.2.6/labware/definitions/Xona_XC-SF150-X4_in_Ramona_chip_holder_16_well_plate.json +73 -0
- {labware-0.2.4 → labware-0.2.6}/labware.egg-info/PKG-INFO +1 -1
- {labware-0.2.4 → labware-0.2.6}/labware.egg-info/SOURCES.txt +3 -0
- {labware-0.2.4 → labware-0.2.6}/tests/test_labware.py +21 -0
- labware-0.2.4/labware/definitions/Ramona_Xona_chip_holder_3_well_plate.json +0 -37
- labware-0.2.4/labware/definitions/Xona_XC-SF150-X4_in_Ramona_chip_holder_12_well_plate.json +0 -50
- {labware-0.2.4 → labware-0.2.6}/LICENSE.txt +0 -0
- {labware-0.2.4 → labware-0.2.6}/README.md +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/__init__.py +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/_version.py +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Akura_384_spheroid_microplate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Akura_96_spheroid_microplate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Axion_M768-SPH-48B_48_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/CELLTREAT_229101_1_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/CellVis_24_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Cellvis_P01-1.5H_1_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Cellvis_P384-1.5H-N_384_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Corning_3335_6_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Corning_351146_6_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Corning_3512_12_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Corning_3527_24_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Corning_353502_6_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Corning_3548_48_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Corning_3599_96_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Corning_3601_96_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Corning_3610_96_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Corning_3764_384_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Corning_3830_384_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Corning_costar_12_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Corning_costar_24_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Corning_costar_6_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Genesee_25-105_6_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Greiner_655090_96_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Greiner_655161_96_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Greiner_655180_96_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Greiner_670180_1_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Greiner_781090_384_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Greiner_781091_384_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Greiner_781092_384_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Greiner_781093_384_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Greiner_781095_384_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Greiner_781096_384_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Greiner_781097_384_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Greiner_781098_384_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Greiner_783092_1536_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Greiner_783892_1536_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Greiner_788876_384_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Ibidi_80636_6_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Ibidi_82426_24_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/InSphero_GRI3D-96IBI_96_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/InSphero_GRI3D-96P_96_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Mimetas_4004-400-B_384_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Mimetas_6401-400-B_384_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Mimetas_6405-400-B_384_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Ramona_full_SBS_plate_scan_1_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Ramona_petri_dish_insert_30_mm.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Ramona_petri_dish_insert_35_mm.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Ramona_petri_dish_insert_40_mm.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Ramona_petri_dish_insert_45_mm.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Ramona_petri_dish_insert_50_mm.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Ramona_petri_dish_insert_55_mm.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Ramona_petri_dish_insert_60_mm.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Ramona_petri_dish_insert_65_mm.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Ramona_petri_dish_insert_70_mm.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Ramona_petri_dish_insert_75_mm.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Ramona_petri_dish_insert_80_mm.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Ramona_petri_dish_insert_85_mm.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Ramona_petri_dish_insert_90_mm.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Ramona_petri_dish_insert_95_mm.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Revvity_phenoplate_384_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Revvity_phenoplate_96_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/SBS_1536_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/SBS_384_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/SBS_96_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/TPP_92406_6_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/TPP_92412_12_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/TPP_92424_24_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Thermo_nunc_140156_1_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Thermo_nunc_142475_24_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Thermo_nunc_142485_24_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Thermo_nunc_150628_12_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Thermo_nunc_165218_1_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Thermo_nunc_165305_96_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Thermo_nunc_167008_96_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Watson_bio_24_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/definitions/Xona_XC-SF150-X4_4_well_plate.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/labware.v1.schema.json +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/py.typed +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware/schema.py +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware.egg-info/dependency_links.txt +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware.egg-info/requires.txt +0 -0
- {labware-0.2.4 → labware-0.2.6}/labware.egg-info/top_level.txt +0 -0
- {labware-0.2.4 → labware-0.2.6}/pyproject.toml +0 -0
- {labware-0.2.4 → labware-0.2.6}/setup.cfg +0 -0
- {labware-0.2.4 → labware-0.2.6}/setup.py +0 -0
|
@@ -1,2 +1,2 @@
|
|
|
1
1
|
# This file has been created by setup.py.
|
|
2
|
-
version = '0.2.
|
|
2
|
+
version = '0.2.6'
|
|
@@ -0,0 +1,60 @@
|
|
|
1
|
+
{
|
|
2
|
+
"$schema": "https://raw.githubusercontent.com/ramonaoptics/labware/main/labware/labware.v1.schema.json",
|
|
3
|
+
"name": "Ramona Xona Chip Holder 3 well",
|
|
4
|
+
"number_of_wells": 3,
|
|
5
|
+
"manufacturer": "Ramona Optics",
|
|
6
|
+
"author": "Ramona Optics",
|
|
7
|
+
"last_updated": "2026-11-17T00:00:00Z",
|
|
8
|
+
"part_number": "Xona X4 chip holder, 3 slide, 36mm pitch, SBS footprint",
|
|
9
|
+
"web_reference": "https://docs.ramonaoptics.com/hardware/mcam_inserts.html",
|
|
10
|
+
"applications": [
|
|
11
|
+
"organ-on-chip",
|
|
12
|
+
"imaging"
|
|
13
|
+
],
|
|
14
|
+
"outer_plate_dimensions": {
|
|
15
|
+
"length": 0.12776,
|
|
16
|
+
"width": 0.08548,
|
|
17
|
+
"height": 0.008,
|
|
18
|
+
"skirt_height": 0.006,
|
|
19
|
+
"upper_outline": [
|
|
20
|
+
[
|
|
21
|
+
0.0061,
|
|
22
|
+
0.0016
|
|
23
|
+
],
|
|
24
|
+
[
|
|
25
|
+
0.12616,
|
|
26
|
+
0.0016
|
|
27
|
+
],
|
|
28
|
+
[
|
|
29
|
+
0.12616,
|
|
30
|
+
0.08388
|
|
31
|
+
],
|
|
32
|
+
[
|
|
33
|
+
0.0016,
|
|
34
|
+
0.08388
|
|
35
|
+
],
|
|
36
|
+
[
|
|
37
|
+
0.0016,
|
|
38
|
+
0.0061
|
|
39
|
+
]
|
|
40
|
+
]
|
|
41
|
+
},
|
|
42
|
+
"well_dimensions": {
|
|
43
|
+
"pitch": 0.036,
|
|
44
|
+
"rows": 1,
|
|
45
|
+
"columns": 3,
|
|
46
|
+
"shape": "rectangle",
|
|
47
|
+
"diameter": 0.0258,
|
|
48
|
+
"width": 0.0258,
|
|
49
|
+
"height": 0.0758,
|
|
50
|
+
"depth": 0.0065,
|
|
51
|
+
"bottom_shape": "flat"
|
|
52
|
+
},
|
|
53
|
+
"alignment_reference": {
|
|
54
|
+
"origin_reference": "A1 well center",
|
|
55
|
+
"offset_from_left_edge": 0.02788,
|
|
56
|
+
"offset_from_top_edge": 0.04274,
|
|
57
|
+
"z_reference": "top surface of plate"
|
|
58
|
+
},
|
|
59
|
+
"notes": "The 3 wells of this definition are the 3 chip pockets of the holder, empty: A1 is the leftmost pocket. NOT A CATALOGUE PLATE. This is a Ramona Optics fixture: an SBS-footprint holder that carries 3 Xona XonaChip X4 chips (75.50 x 25.50mm, slide format) with their long axis along the plate's width, so that they can be driven as one plate. Its pockets are 36.00mm apart, twice the MCAM's 18mm micro-camera pitch, so every chip sits under the same camera column. HISTORY: added 2026-10-15/16 (issue #25, PR #26) from the requester's description alone, before any drawing existed, with a provisional 14.35mm height (the ANSI/SLAS default), 25.50 x 75.50mm pockets (the chip without clearance) and a 1.00mm pocket depth. On 2026-11-17 (issue #66) Ramona's CAD replaced all three: height 8.00mm, pockets 25.80 x 75.80mm, depth 6.50mm; pocket centres and pitch are unchanged. CONTROLLING DOCUMENT: Ramona's own dimension drawing 'Xona Chip Holders - 3x and 4x Dimensions' (Tripp Spivey, 2026-11-17, 4 pages: top views of both holders rebuilt from the Onshape model 'Xona Chip-X4 Holder' and a dimension summary), with the matching STL exports 'Xona_Holder_3x36mm.stl' and 'Xona_Holder_4x27mm.stl' (tessellated at 0.005mm chord tolerance from part studios 'Xona Holder 3x36mm' and 'Xona Holder 4x27mm'), shared in #labware-requests on 2026-11-17 (https://ramonaoptics.slack.com/archives/C0BT14F1GTF/p1794930180814739). They are internal Ramona documents, on file at Ramona and not published; the web_reference is Ramona's insert documentation page. The drawing PRINTS the footprint 127.76 x 85.48 x 8.00mm, the pitch, the top-left-corner-to-chip-1 offsets (4x: 23.38 / 42.74mm; 3x: 27.88 / 42.74mm) and the 25.80 x 75.80mm chip pocket, and marks the chamfered corner as A1 at the top left with chip 1 the left-hand pocket. Every other holder number below (skirt and body steps, the chamfer's size, the floor ledge, windows, notches, recesses) is read off the vertex coordinates of the STL, whose origin is the plate centre, so they are the design's nominal values, not measurements of a part. FOOTPRINT AND SKIRT: 127.76 x 85.48mm with 2.00mm corner radii, straight walls from z = 0 to 6.00mm, which is skirt_height. Above that the body is inset 1.60mm on every side (124.56 x 82.28mm, sharp corners) up to the top face at 8.00mm, the plate's height; skirt_thickness is therefore not a separate flange width and is left out. The body has ONE chamfered corner, 4.50 x 4.50mm at 45 degrees, recorded in upper_outline at the top-left (A1) corner; the skirt's outline is the plain rounded rectangle and is not recorded. ORIENTATION, from the drawing: A1 is the chamfered top-left corner and chip 1 the left-hand pocket; in the STL's coordinates that is +y as the plate's top edge (row A) and -x as its left edge. POCKETS: rectangular, 25.80mm along the plate's length x 75.80mm along its width (the 25.50 x 75.50mm Xona X4 chip plus 0.30mm clearance each way), centred at y = 42.74mm and x = 27.88, 63.88 and 99.88mm, 36.0mm apart. Each pocket has a 1.60mm radius relief notch in each end wall near each corner (centred 11.30mm either side of the pocket centre), not recordable in this schema. The pocket floor, the ledge the chip rests on, is at z = 1.50mm, so a pocket is 6.50mm deep from the top face. Through the floor, each pocket has four imaging windows, 17.50 x 9.00mm with 1.00mm corner radii, centred on the pocket's x and at 6.00 and 18.00mm either side of its centre in y - exactly under the four culture units A-D of a centred chip (Xona's 12.00mm unit pitch). Each end of the plate has a finger recess from the outer pocket's end wall outward, 28.00mm along the plate's width with 3.00mm corner radii, floor at z = 1.50mm, also not recordable here. NOT IN THE DRAWING OR THE MODEL, and so not recorded: material, colour, surface finish, tolerances. 'depth' is the pocket depth; the pocket has no closed bottom to image through, so bottom_elevation, bottom_thickness and floor_height are left out. 'diameter' repeats the pocket's shorter side, as for any rectangular well. CORRECTION, 2026-11-17, applied on this branch before merge. The requester (Slack UT35U0XPX, who made the original request) wrote (https://ramonaoptics.slack.com/archives/C0BT14F1GTF/p1794945075529829): 'The STEP files you used are outdated. Rebuild both holders from the new set posted in this thread ... The dimensions PDF is the controlling drawing. A1 is the top-left corner. The 27 mm pitch on the 4-chip holder is intended.' The first version of this branch was built from Onshape STEP AP242 exports of 2026-10-29 ('Xona Holder 3x36mm - Base Plate.step' and 'Xona Holder 4x27mm.step'). The holder was rebuilt from the new set as asked, and NO VALUE CHANGED: every printed number on the new drawing equals the value already in this file, every one of the 306 (3x) and 394 (4x) B-rep vertices of the old STEP export lies within 0.02mm of a vertex of the new STL, both STLs have their horizontal faces at the same four levels (0, 1.50, 6.00 and 8.00mm) and the same extents (127.76 x 85.48 x 8.00mm), and the STL volumes (37,011.7 and 28,497.4mm3) match the drawing's 37,012 and 28,497mm3. What changed is the provenance: the controlling document is now the dimension drawing, and A1 at the chamfered top-left corner, previously an assumption because the STEP model carried no A1 marking, is now printed on the drawing and confirmed by the requester. "
|
|
60
|
+
}
|
|
@@ -0,0 +1,60 @@
|
|
|
1
|
+
{
|
|
2
|
+
"$schema": "https://raw.githubusercontent.com/ramonaoptics/labware/main/labware/labware.v1.schema.json",
|
|
3
|
+
"name": "Ramona Xona Chip Holder 4 well",
|
|
4
|
+
"number_of_wells": 4,
|
|
5
|
+
"manufacturer": "Ramona Optics",
|
|
6
|
+
"author": "Ramona Optics",
|
|
7
|
+
"last_updated": "2026-11-17T00:00:00Z",
|
|
8
|
+
"part_number": "Xona X4 chip holder, 4 slide, 27mm pitch, SBS footprint",
|
|
9
|
+
"web_reference": "https://docs.ramonaoptics.com/hardware/mcam_inserts.html",
|
|
10
|
+
"applications": [
|
|
11
|
+
"organ-on-chip",
|
|
12
|
+
"imaging"
|
|
13
|
+
],
|
|
14
|
+
"outer_plate_dimensions": {
|
|
15
|
+
"length": 0.12776,
|
|
16
|
+
"width": 0.08548,
|
|
17
|
+
"height": 0.008,
|
|
18
|
+
"skirt_height": 0.006,
|
|
19
|
+
"upper_outline": [
|
|
20
|
+
[
|
|
21
|
+
0.0061,
|
|
22
|
+
0.0016
|
|
23
|
+
],
|
|
24
|
+
[
|
|
25
|
+
0.12616,
|
|
26
|
+
0.0016
|
|
27
|
+
],
|
|
28
|
+
[
|
|
29
|
+
0.12616,
|
|
30
|
+
0.08388
|
|
31
|
+
],
|
|
32
|
+
[
|
|
33
|
+
0.0016,
|
|
34
|
+
0.08388
|
|
35
|
+
],
|
|
36
|
+
[
|
|
37
|
+
0.0016,
|
|
38
|
+
0.0061
|
|
39
|
+
]
|
|
40
|
+
]
|
|
41
|
+
},
|
|
42
|
+
"well_dimensions": {
|
|
43
|
+
"pitch": 0.027,
|
|
44
|
+
"rows": 1,
|
|
45
|
+
"columns": 4,
|
|
46
|
+
"shape": "rectangle",
|
|
47
|
+
"diameter": 0.0258,
|
|
48
|
+
"width": 0.0258,
|
|
49
|
+
"height": 0.0758,
|
|
50
|
+
"depth": 0.0065,
|
|
51
|
+
"bottom_shape": "flat"
|
|
52
|
+
},
|
|
53
|
+
"alignment_reference": {
|
|
54
|
+
"origin_reference": "A1 well center",
|
|
55
|
+
"offset_from_left_edge": 0.02338,
|
|
56
|
+
"offset_from_top_edge": 0.04274,
|
|
57
|
+
"z_reference": "top surface of plate"
|
|
58
|
+
},
|
|
59
|
+
"notes": "The 4 wells of this definition are the 4 chip pockets of the holder, empty: A1 is the leftmost pocket. NOT A CATALOGUE PLATE. This is a Ramona Optics fixture: an SBS-footprint holder that carries 4 Xona XonaChip X4 chips (75.50 x 25.50mm, slide format) with their long axis along the plate's width, so that they can be driven as one plate. Its pockets are 27.00mm apart (3 x 9mm), leaving 1.20mm ribs between neighbours; the four-pocket block is centred on the plate (23.38 + 3 x 27.00 = 104.38 = 127.76 - 23.38). This is the four-chip variant of the 36mm-pitch Ramona_Xona_chip_holder_3_well_plate and shares its footprint, body, pocket size, floor and windows; only the pocket count and pitch differ. 27mm is not a multiple of the 18mm micro-camera pitch, so unlike the 36mm holder the chips do not all sit at the same position under a camera column. Requested 2026-11-17, issue #66. CONTROLLING DOCUMENT: Ramona's own dimension drawing 'Xona Chip Holders - 3x and 4x Dimensions' (Tripp Spivey, 2026-11-17, 4 pages: top views of both holders rebuilt from the Onshape model 'Xona Chip-X4 Holder' and a dimension summary), with the matching STL exports 'Xona_Holder_3x36mm.stl' and 'Xona_Holder_4x27mm.stl' (tessellated at 0.005mm chord tolerance from part studios 'Xona Holder 3x36mm' and 'Xona Holder 4x27mm'), shared in #labware-requests on 2026-11-17 (https://ramonaoptics.slack.com/archives/C0BT14F1GTF/p1794930180814739). They are internal Ramona documents, on file at Ramona and not published; the web_reference is Ramona's insert documentation page. The drawing PRINTS the footprint 127.76 x 85.48 x 8.00mm, the pitch, the top-left-corner-to-chip-1 offsets (4x: 23.38 / 42.74mm; 3x: 27.88 / 42.74mm) and the 25.80 x 75.80mm chip pocket, and marks the chamfered corner as A1 at the top left with chip 1 the left-hand pocket. Every other holder number below (skirt and body steps, the chamfer's size, the floor ledge, windows, notches, recesses) is read off the vertex coordinates of the STL, whose origin is the plate centre, so they are the design's nominal values, not measurements of a part. FOOTPRINT AND SKIRT: 127.76 x 85.48mm with 2.00mm corner radii, straight walls from z = 0 to 6.00mm, which is skirt_height. Above that the body is inset 1.60mm on every side (124.56 x 82.28mm, sharp corners) up to the top face at 8.00mm, the plate's height; skirt_thickness is therefore not a separate flange width and is left out. The body has ONE chamfered corner, 4.50 x 4.50mm at 45 degrees, recorded in upper_outline at the top-left (A1) corner; the skirt's outline is the plain rounded rectangle and is not recorded. ORIENTATION, from the drawing: A1 is the chamfered top-left corner and chip 1 the left-hand pocket; in the STL's coordinates that is +y as the plate's top edge (row A) and -x as its left edge. POCKETS: rectangular, 25.80mm along the plate's length x 75.80mm along its width (the 25.50 x 75.50mm Xona X4 chip plus 0.30mm clearance each way), centred at y = 42.74mm and x = 23.38, 50.38, 77.38 and 104.38mm, 27.0mm apart. Each pocket has a 1.60mm radius relief notch in each end wall near each corner (centred 11.30mm either side of the pocket centre), not recordable in this schema. The pocket floor, the ledge the chip rests on, is at z = 1.50mm, so a pocket is 6.50mm deep from the top face. Through the floor, each pocket has four imaging windows, 17.50 x 9.00mm with 1.00mm corner radii, centred on the pocket's x and at 6.00 and 18.00mm either side of its centre in y - exactly under the four culture units A-D of a centred chip (Xona's 12.00mm unit pitch). Each end of the plate has a finger recess from the outer pocket's end wall outward, 28.00mm along the plate's width with 3.00mm corner radii, floor at z = 1.50mm, also not recordable here. NOT IN THE DRAWING OR THE MODEL, and so not recorded: material, colour, surface finish, tolerances. 'depth' is the pocket depth; the pocket has no closed bottom to image through, so bottom_elevation, bottom_thickness and floor_height are left out. 'diameter' repeats the pocket's shorter side, as for any rectangular well. CORRECTION, 2026-11-17, applied on this branch before merge. The requester (Slack UT35U0XPX, who made the original request) wrote (https://ramonaoptics.slack.com/archives/C0BT14F1GTF/p1794945075529829): 'The STEP files you used are outdated. Rebuild both holders from the new set posted in this thread ... The dimensions PDF is the controlling drawing. A1 is the top-left corner. The 27 mm pitch on the 4-chip holder is intended.' The first version of this branch was built from Onshape STEP AP242 exports of 2026-10-29 ('Xona Holder 3x36mm - Base Plate.step' and 'Xona Holder 4x27mm.step'). The holder was rebuilt from the new set as asked, and NO VALUE CHANGED: every printed number on the new drawing equals the value already in this file, every one of the 306 (3x) and 394 (4x) B-rep vertices of the old STEP export lies within 0.02mm of a vertex of the new STL, both STLs have their horizontal faces at the same four levels (0, 1.50, 6.00 and 8.00mm) and the same extents (127.76 x 85.48 x 8.00mm), and the STL volumes (37,011.7 and 28,497.4mm3) match the drawing's 37,012 and 28,497mm3. What changed is the provenance: the controlling document is now the dimension drawing, and A1 at the chamfered top-left corner, previously an assumption because the STEP model carried no A1 marking, is now printed on the drawing and confirmed by the requester. The 27.00mm pitch is the requester's stated intent, not a drafting error."
|
|
60
|
+
}
|
|
@@ -0,0 +1,46 @@
|
|
|
1
|
+
{
|
|
2
|
+
"$schema": "https://raw.githubusercontent.com/ramonaoptics/labware/main/labware/labware.v1.schema.json",
|
|
3
|
+
"name": "Watson Bio Chimney-well 196-96FIS 96 well",
|
|
4
|
+
"number_of_wells": 96,
|
|
5
|
+
"manufacturer": "Watson Bio Lab",
|
|
6
|
+
"author": "Ramona Optics",
|
|
7
|
+
"last_updated": "2026-11-03T00:00:00Z",
|
|
8
|
+
"part_number": "196-96FIS",
|
|
9
|
+
"web_reference": "https://watsonbiolab.com/product/testplate/microtiter-ind/",
|
|
10
|
+
"drawing_reference": "https://watsonbiolab.com/pdf/manual/EN_MicroPlate_DimensionTable.pdf",
|
|
11
|
+
"applications": ["cell culture"],
|
|
12
|
+
|
|
13
|
+
"outer_plate_dimensions": {
|
|
14
|
+
"length": 0.1277,
|
|
15
|
+
"width": 0.0854,
|
|
16
|
+
"height": 0.0146,
|
|
17
|
+
"height_with_lid": 0.0175,
|
|
18
|
+
"skirt_height": 0.0076
|
|
19
|
+
},
|
|
20
|
+
|
|
21
|
+
"well_dimensions": {
|
|
22
|
+
"pitch": 0.009,
|
|
23
|
+
"rows": 8,
|
|
24
|
+
"columns": 12,
|
|
25
|
+
"shape": "circle",
|
|
26
|
+
"diameter": 0.007,
|
|
27
|
+
"depth": 0.0116,
|
|
28
|
+
"bottom_shape": "flat",
|
|
29
|
+
"bottom_color": "clear",
|
|
30
|
+
"bottom_material": "polystyrene",
|
|
31
|
+
"bottom_thickness": 0.0015,
|
|
32
|
+
"bottom_elevation": 0.0016,
|
|
33
|
+
"floor_height": 0.0031,
|
|
34
|
+
"wall_material": "polystyrene",
|
|
35
|
+
"wall_color": "clear"
|
|
36
|
+
},
|
|
37
|
+
|
|
38
|
+
"alignment_reference": {
|
|
39
|
+
"origin_reference": "A1 well center",
|
|
40
|
+
"offset_from_left_edge": 0.0142,
|
|
41
|
+
"offset_from_top_edge": 0.0111,
|
|
42
|
+
"z_reference": "top surface of plate"
|
|
43
|
+
},
|
|
44
|
+
|
|
45
|
+
"notes": "WATSON Bio Lab chimney-well 96 well microplate, flat bottom, individual (free-standing chimney) wells in a moat, polystyrene, clear, with lid, sterile, 50 individually packaged. 196-96FIS; the dimensions chart lists 197-96CIPS (with lid) under the same row. Not the same mould as the flat-top 96 well plates 196-96FS / 195-96F (380 uL, different well diameter and depth). Every dimension is printed in the WATSON 'Dimensions Chart for Microplates' (EN_MicroPlate_DimensionTable.pdf, created 2024-04-11, no revision printed), row '96 well flat bottom, Individual well [capacity of a well: 450 uL]', all in mm: plate length 127.7, width 85.4, height 14.6, lid + plate height 17.5, well depth 11.6, bottom surface height 1.6 (underside of the well bottom above the resting plane: bottom_elevation), A1 centre 11.1 from the top edge and 14.2 from the left edge, well spacing 9.0, well bottom diameter 7.0 and well (top) diameter 7.0 (a straight well, so no diameter_top), flange height 7.6 (skirt_height; the chart's section draws it as the height of the outer step), well bottom thickness 1.5. floor_height 3.1 mm is derived, 1.6 + 1.5. The chart's own numbers disagree by 0.1 mm: plate height minus floor height gives 11.5 mm against the printed well depth of 11.6 mm; the printed depth is used. The product page's well figure gives the same 7.0 mm diameter and 11.6 mm depth and a bottom area of 0.4 cm^2 (d = 7.1 mm). 450 uL is the vendor's capacity per well (pi x 3.5^2 x 11.6 = 446 uL), not a recommended working volume, so no working volume is recorded. The product page gives the size as 127.7 x 85.4 x 17.5 mm with lid. The skirt outline, skirt thickness and the corner shape are not on the chart, which is a generic diagram drawn for a 12 well plate, so they are left to the standard. Units in meters."
|
|
46
|
+
}
|
|
@@ -0,0 +1,73 @@
|
|
|
1
|
+
{
|
|
2
|
+
"$schema": "https://raw.githubusercontent.com/ramonaoptics/labware/main/labware/labware.v1.schema.json",
|
|
3
|
+
"name": "Xona XC-SF150-X4 in Ramona Chip Holder 12 well",
|
|
4
|
+
"number_of_wells": 12,
|
|
5
|
+
"manufacturer": "Ramona Optics",
|
|
6
|
+
"author": "Ramona Optics",
|
|
7
|
+
"last_updated": "2026-11-17T00:00:00Z",
|
|
8
|
+
"part_number": "XC-SF150-X4 in Ramona Xona X4 chip holder",
|
|
9
|
+
"web_reference": "https://xonamicrofluidics.com/product/xc-sf150-x4/",
|
|
10
|
+
"drawing_reference": "https://xonamicrofluidics.com/wp-content/uploads/2023/02/XC-SF150-x4-InnerDim.png",
|
|
11
|
+
"applications": [
|
|
12
|
+
"organ-on-chip",
|
|
13
|
+
"neural",
|
|
14
|
+
"primary cells",
|
|
15
|
+
"co-culture",
|
|
16
|
+
"cell migration",
|
|
17
|
+
"imaging",
|
|
18
|
+
"fluorescence"
|
|
19
|
+
],
|
|
20
|
+
"outer_plate_dimensions": {
|
|
21
|
+
"length": 0.12776,
|
|
22
|
+
"width": 0.08548,
|
|
23
|
+
"height": 0.008,
|
|
24
|
+
"skirt_height": 0.006,
|
|
25
|
+
"upper_outline": [
|
|
26
|
+
[
|
|
27
|
+
0.0061,
|
|
28
|
+
0.0016
|
|
29
|
+
],
|
|
30
|
+
[
|
|
31
|
+
0.12616,
|
|
32
|
+
0.0016
|
|
33
|
+
],
|
|
34
|
+
[
|
|
35
|
+
0.12616,
|
|
36
|
+
0.08388
|
|
37
|
+
],
|
|
38
|
+
[
|
|
39
|
+
0.0016,
|
|
40
|
+
0.08388
|
|
41
|
+
],
|
|
42
|
+
[
|
|
43
|
+
0.0016,
|
|
44
|
+
0.0061
|
|
45
|
+
]
|
|
46
|
+
]
|
|
47
|
+
},
|
|
48
|
+
"well_dimensions": {
|
|
49
|
+
"pitch": 0.012,
|
|
50
|
+
"row_pitch": 0.012,
|
|
51
|
+
"column_pitch": 0.036,
|
|
52
|
+
"rows": 4,
|
|
53
|
+
"columns": 3,
|
|
54
|
+
"shape": "rectangle",
|
|
55
|
+
"diameter": 0.001,
|
|
56
|
+
"width": 0.004,
|
|
57
|
+
"height": 0.001,
|
|
58
|
+
"depth": 8e-05,
|
|
59
|
+
"bottom_shape": "flat",
|
|
60
|
+
"bottom_color": "clear",
|
|
61
|
+
"bottom_material": "cyclo_olefin",
|
|
62
|
+
"bottom_thickness": 0.00015,
|
|
63
|
+
"wall_material": "cyclo_olefin",
|
|
64
|
+
"wall_color": "clear"
|
|
65
|
+
},
|
|
66
|
+
"alignment_reference": {
|
|
67
|
+
"origin_reference": "A1 well center",
|
|
68
|
+
"offset_from_left_edge": 0.02788,
|
|
69
|
+
"offset_from_top_edge": 0.02474,
|
|
70
|
+
"z_reference": "top surface of plate"
|
|
71
|
+
},
|
|
72
|
+
"notes": "The twelve wells of this definition are the twelve imaging regions of three Xona XC-SF150-X4 chips loaded in the Ramona holder: four culture units (A-D) on each of three chips, each well covering one unit's microgroove barrier between its two compartment channels. It is the file to select when three chips are loaded in the holder. \n TWELVE WELLS ON A RECTANGULAR LATTICE, and what this replaced. The twelve imaging regions do not sit on a square lattice: the four units within a chip are 12.00mm apart along the plate's width, and the chips are 36.00mm apart along its length. Until 2026-10-16 the schema had a single 'pitch' shared by both axes, so this grid could not be written, and this file took the request's own fallback: 1 row x 3 columns on the 36.00mm chip pitch, each well a 4.00 x 37.00mm strip spanning one chip's four barriers A-D, three addressable wells A1-A3. That is SUPERSEDED. labware now has row_pitch and column_pitch (labware/schema.py, WellDimensions; merged to main in PR #27), so the real grid is written directly: 4 rows x 3 columns, row_pitch 12.00mm, column_pitch 36.00mm, one well per imaging region, twelve wells A1-A3 through D1-D3. Each well is the 4.00 x 1.00mm imaging rectangle of the chip-only file rather than a 37.00mm strip, so a scan covers the twelve regions and not the 11.00mm of chip between them. 'pitch' is kept, as the schema requires, and carries the SMALLER of the two (12.00mm), which is what the schema suggests so that a reader which does not know the new keys still places every well inside the plate's real grid. A READER THAT KNOWS ONLY 'pitch' PLACES THIS PLATE WRONG: it puts the three columns 12.00mm apart instead of 36.00mm, so the two right-hand chips' wells land on the first chip and on the holder's ribs. This definition is only correct for a reader that reads row_pitch and column_pitch. The labware plate viewer reads both as of 2026-10-16 (see the RENDERING correction below); python-owl's acquisition path still reads 'pitch' alone in every release up to 0.19.639, so this plate is only scanned correctly once that reads the two keys as well. \n GEOMETRY. From the request and confirmed against the chip drawing: in the holder the chips lie with their 75.50mm axis along the plate's 85.48mm width, so the four units of a chip step in y (the rows) and the chips step in x (the columns). The unit centres are at y = 24.74, 36.74, 48.74 and 60.74mm - A at 42.74 - 3 x 12.00 / 2 = 24.74 - and the chip columns at the pocket centres x = 27.88, 63.88 and 99.88mm. A1 is therefore the unit A barrier of the left-hand chip, at 27.88mm from the left edge and 24.74mm from the top edge. Both are centred: 27.88 + 2 x 36.00 = 99.88 = 127.76 - 27.88, and 24.74 + 3 x 12.00 = 60.74 = 85.48 - 24.74. Each well is 4.00mm across the barriers (x, the plate's length) by 1.00mm along the channels (y, the plate's width), as in the chip-only file; 'diameter' repeats the shorter side, 1.00mm. The twelve wells span x 25.88-101.88mm and y 24.24-61.24mm, inside the pockets' x 15.13-112.63mm and y 4.99-80.49mm, so nothing overruns a pocket, let alone the footprint. \n\nTHE HOLDER. NOT A CATALOGUE PLATE. This is a Ramona Optics fixture: an SBS-footprint holder that carries three Xona XonaChip X4 chips (75.50 x 25.50mm, slide format) so that they can be driven as one plate. Xona themselves describe a four-chip arrangement - 'these chips (the size of standard microscope slides) can be combined in a 4-slide plate holder to yield sixteen (16) sample units' - but that is Xona's own tray, not this holder: Ramona's carries three because the pockets are spaced to the MCAM's 18mm micro-camera pitch (see CORRECTION below), and only three 36mm steps fit the SBS footprint. When this file was first written no drawing of the holder existed; Ramona's dimension drawing of 2026-11-17 now does (see Ramona_Xona_chip_holder_3_well_plate). \n\nTHE HOLDER'S GEOMETRY is that of Ramona_Xona_chip_holder_3_well_plate, from Ramona's dimension drawing 'Xona Chip Holders - 3x and 4x Dimensions' and STL 'Xona_Holder_3x36mm.stl' of 2026-11-17 (see that file's notes): footprint 127.76 x 85.48mm, skirt 6.00mm high, body inset 1.60mm to an 8.00mm top with one 4.50mm chamfer at the A1 corner (A1 at the chamfered top-left corner, as the drawing marks it), pockets 25.80 x 75.80mm at x = 27.88, 63.88 and 99.88mm, y = 42.74mm, floor ledge at z = 1.50mm, with four 17.50 x 9.00mm windows per pocket under units A-D. Until 2026-11-17 this file carried provisional values for the holder (14.35mm height, pockets at the chip's nominal size, height of the chip floor unknown); issue #66 replaced them from the CAD. On 2026-11-17 the requester had the holder rebuilt from the newer drawing and STLs; no value changed (see Ramona_Xona_chip_holder_3_well_plate's 2026-11-17 CORRECTION). The 0.30mm pocket clearance lets a chip sit up to 0.15mm off centre each way, which no field here captures. 'height' 8.00mm is the holder's top face; the chip's overall thickness is not published, so whether its reservoir bosses stand above 8.00mm is not known.\n\nTHE CHIP. CONTROLLING DOCUMENTS, both published by Xona Microfluidics on their XC-SF150-X4 product page. (1) The dimensioned plan drawing 'XC-SF150-x4-InnerDim.png' (drawing_reference), which prints, as callouts: 75.50mm overall length, 25.50mm overall width, 19.75mm from the end of the chip to the centre line of unit A, 12.00mm unit-to-unit pitch, 10.00mm between the centres of the two large wells of a unit, 7.00mm between the centres of the two small ports of a unit, O6.0 for the large wells and O2.0 for the small ports. A companion drawing 'XC-SF150-x4-OuterDim.png' repeats 75.50 x 25.50mm, and 'XC-SF150-x4-UnitView.png' is an undimensioned enlarged plan of one unit. The drawings carry no revision or date; they were uploaded in 2023-02 per their URL. (2) The vendor's specification text, spread over the product page, the XONACHIPS page, the FAQ page and the 'Introducing XonaChips' / 'Introducing the X4 XonaChip' posts: '(4) compartmentalized culture units, each with 150 um wide microgroove barriers'; 'Each unit contains (18) microgrooves connecting the compartments'; 'Each microgroove cross-section for all XonaChips is approximately 7 um x 7 um'; 'Main channel heights are approximately 80 um'; 'a smaller cell loading port approximately 2 mm in diameter'; 'XonaChips are made of cyclic olefin copolymer (COC)'; 'The XonaChip consists of a molded COC top bonded to a thin optically transparent 150 um thick COC film'; 'The outside dimensions of the X4 chip are the same as a standard microscope slide'; 'Size: 75 mm x 25 mm'. Where the catalogue text's rounded '75 mm x 25 mm' and the drawing's 75.50 x 25.50mm disagree, the drawing is followed. \n\nMATERIAL, answering the request's question directly: this chip is NOT PDMS on a glass coverslip. Xona's FAQ separates the two product lines - 'The silicone devices are made of poly(dimethylsiloxane) (PDMS) and XonaChips are made of cyclic olefin copolymer (COC)'. XC-SF150-X4 is a XonaChip, an injection-moulded COC top bonded to a 150 um COC film, so bottom_material and wall_material are cyclo_olefin and bottom_thickness is the published 150 um film. The PDMS part with the same barrier is the separate SF150x2 'Small Footprint Silicone Device', which is a different part and a different size (about 28 x 18 mm). No refractive index is published for the film and none is recorded; COC is typically about 1.53 at 589 nm, which is NOT taken from a Xona document and is mentioned here for orientation only. \n\nTHE IMAGING REGION, and how its size was obtained. The request asks for a well that covers the microgroove barrier between the two compartment channels at the centre of a unit, sized from Xona's published specs. Xona publishes the barrier length (150 um) but publishes NO channel width and NO channel length for the X4 unit. The '1.5 mm x 7 mm x 0.060 mm (W x L x H) main channels' and '0.01 mm x 0.005 mm microgrooves' figures that circulate for XonaChips come from the JoVE protocol 'Use of Pre-Assembled Plastic Microfluidic Chips for Compartmentalizing Primary Murine Neurons' (doi:10.3791/58421), which describes the 2-compartment XC150 / XC450 / XC900 chips, not this small-footprint 4-unit chip, and they also contradict Xona's own site (80 um channel height, 7 x 7 um microgrooves). They were therefore NOT used. \nThe region's size across the barrier is DERIVED from two printed callouts only: the two large wells of a unit are 10.00mm apart and are O6.0, so the open fluidic region between their edges is 10.00 - 6.00 = 4.00mm, centred on the unit's centre. The region's size along the channels is SCALED off the published UnitView drawing, assumed to scale: at 1600 x 1280 px the two O6.0 circles measure 420 px across and their centres 707 px apart, giving 70.0 px/mm and 70.7 px/mm in x, and the two O2.0 port centres measure 494 px apart, giving 70.6 px/mm in y - two independent calibrations per axis agreeing to 1% and the two axes agreeing to 0.2%. On that scale the microgroove bank, drawn as the hatched strip at the unit's centre, spans 71 px = 1.00mm, and the channel neck either side of it spans 71-80 px = 1.00-1.13mm. The well is therefore recorded as 4.00mm across the barrier by 1.00mm along the channels, centred on the unit's centre. Uncertainty on the 1.00mm value is about +/-0.1mm: the drawing's line weight is 4 px (0.06mm) and the two measurements of the neck differ by 0.13mm. It is corroborated by the vendor's own text: 18 microgrooves of 7 um width spread over 1.00mm is a 56 um groove pitch, which matches the drawn hatching. The 150 um barrier itself measures 15 px = 0.21mm on the same calibration, which is the printed 150 um plus two line widths, so the drawing is consistent with its own callout. \n\nNOT PUBLISHED BY XONA, and therefore not written as a vendor number anywhere in this file: overall chip thickness; well and port depths; reservoir working volumes; any tolerance; the chip's corner radius; sterility; surface treatment of the channels (the chips ship with a separate 'XC Pre-Coat' tube, which is a reagent, not a moulded-in treatment).\n\nZ, and what is not recorded. bottom_thickness 150 um is the chip's COC film, the layer the objective looks through. From the CAD, the chip's film rests on the pocket floor ledge 1.50mm above the resting plane, so the film's underside is at 1.50mm and the sample sits at 1.65mm (1.50mm + the 150 um film). Those are NOT written as bottom_elevation and floor_height: with 'depth' the chip's 80 um channel height and 'height' the holder's 8.00mm top, readers that take a well's top at the plate's top would place the floor at 7.92mm, and the two would contradict each other. Recording them waits on a decision about which height a chips-loaded definition should carry. 'depth' 80 um is the chip's published channel height, as in the chip-only file. CHIP HEIGHT vs PLATE THICKNESS, per the requester's 2026-10-15 follow-up. The 1.00mm figure is kept, still provisional: the requester confirms that the purchasing link in #team_vireo carries no thickness (it is the same plan view already used here), and that Xona's product page, drawings and FAQ give none either, so there is nothing to replace the ISO 8037-1 slide inference with yet. But 1.00mm is the thickness of the flat slide plate ONLY. Xona's product photographs show the O6.0 reservoirs and O2.0 loading ports standing up from that plate as raised bosses, so the chip's overall height is MORE than 1.00mm by an unmeasured amount. Anything that depends on total height rather than on the optical path - pocket depth, lid or tray clearance, a chip sitting flush - must not assume 1.00mm. A caliper measurement of a chip in hand is to follow and will settle both numbers. \n CORRECTION, 2026-10-16, applied on this branch before merge, the second correction from the same requester. Slack UT35U0XPX, who made the original request, wrote: 'I have just enabled different pitch in rows and columns. please use that to create a more accurate schema.' The evidence is the schema itself: row_pitch and column_pitch are on labware main as of PR #27 (commit a204bc5, 2026-10-15). No vendor document is contradicted - the chip's 12.00mm unit pitch is Xona's printed callout and is unchanged, the holder's 36.00mm chip pitch is the requester's own corrected figure and is unchanged; what changed is only that the two can now be written as one grid instead of being collapsed into three strips. Superseded values recorded above. The chip-only and empty-holder files are untouched: each has a single axis of wells, so neither has two pitches to record. \n \n RENDERING, 2026-10-16, no dimension changed. The requester (Slack UT35U0XPX, who made the original request) asked for the renderer to be fixed rather than the numbers: 'please update the render code as well to make the renders look correct'. The panels published with this branch were drawn by python-owl's labware plate viewer, which read 'pitch' alone and therefore drew this plate's three columns 12.00mm apart, and drew the empty holder's 75.50mm pockets clamped to 34.92mm, its single row of wells having no neighbour to leave a wall to. The viewer now carries a spacing per axis and clamps a well to its pitch only along an axis that holds more than one well; it was checked against all 75 definitions in this repository and the well centres, well sizes and warnings of the other 73 are unchanged. That change is in python-owl (examples_internal/labware_plate_viewer.py), NOT in this repository, and it is not merged there yet. NO VALUE IN THIS FILE CHANGED: the earlier panels were wrong about a correct file, which is why the only thing the correction touched was the code that draws them. Use row_pitch, column_pitch and the origin reference to compute all well centers; 'pitch' alone is not enough for this plate."
|
|
73
|
+
}
|
|
@@ -0,0 +1,73 @@
|
|
|
1
|
+
{
|
|
2
|
+
"$schema": "https://raw.githubusercontent.com/ramonaoptics/labware/main/labware/labware.v1.schema.json",
|
|
3
|
+
"name": "Xona XC-SF150-X4 in Ramona Chip Holder 16 well",
|
|
4
|
+
"number_of_wells": 16,
|
|
5
|
+
"manufacturer": "Ramona Optics",
|
|
6
|
+
"author": "Ramona Optics",
|
|
7
|
+
"last_updated": "2026-11-17T00:00:00Z",
|
|
8
|
+
"part_number": "XC-SF150-X4 in Ramona Xona X4 chip holder, 4 slide, 27mm pitch",
|
|
9
|
+
"web_reference": "https://xonamicrofluidics.com/product/xc-sf150-x4/",
|
|
10
|
+
"drawing_reference": "https://xonamicrofluidics.com/wp-content/uploads/2023/02/XC-SF150-x4-InnerDim.png",
|
|
11
|
+
"applications": [
|
|
12
|
+
"organ-on-chip",
|
|
13
|
+
"neural",
|
|
14
|
+
"primary cells",
|
|
15
|
+
"co-culture",
|
|
16
|
+
"cell migration",
|
|
17
|
+
"imaging",
|
|
18
|
+
"fluorescence"
|
|
19
|
+
],
|
|
20
|
+
"outer_plate_dimensions": {
|
|
21
|
+
"length": 0.12776,
|
|
22
|
+
"width": 0.08548,
|
|
23
|
+
"height": 0.008,
|
|
24
|
+
"skirt_height": 0.006,
|
|
25
|
+
"upper_outline": [
|
|
26
|
+
[
|
|
27
|
+
0.0061,
|
|
28
|
+
0.0016
|
|
29
|
+
],
|
|
30
|
+
[
|
|
31
|
+
0.12616,
|
|
32
|
+
0.0016
|
|
33
|
+
],
|
|
34
|
+
[
|
|
35
|
+
0.12616,
|
|
36
|
+
0.08388
|
|
37
|
+
],
|
|
38
|
+
[
|
|
39
|
+
0.0016,
|
|
40
|
+
0.08388
|
|
41
|
+
],
|
|
42
|
+
[
|
|
43
|
+
0.0016,
|
|
44
|
+
0.0061
|
|
45
|
+
]
|
|
46
|
+
]
|
|
47
|
+
},
|
|
48
|
+
"well_dimensions": {
|
|
49
|
+
"pitch": 0.012,
|
|
50
|
+
"row_pitch": 0.012,
|
|
51
|
+
"column_pitch": 0.027,
|
|
52
|
+
"rows": 4,
|
|
53
|
+
"columns": 4,
|
|
54
|
+
"shape": "rectangle",
|
|
55
|
+
"diameter": 0.001,
|
|
56
|
+
"width": 0.004,
|
|
57
|
+
"height": 0.001,
|
|
58
|
+
"depth": 8e-05,
|
|
59
|
+
"bottom_shape": "flat",
|
|
60
|
+
"bottom_color": "clear",
|
|
61
|
+
"bottom_material": "cyclo_olefin",
|
|
62
|
+
"bottom_thickness": 0.00015,
|
|
63
|
+
"wall_material": "cyclo_olefin",
|
|
64
|
+
"wall_color": "clear"
|
|
65
|
+
},
|
|
66
|
+
"alignment_reference": {
|
|
67
|
+
"origin_reference": "A1 well center",
|
|
68
|
+
"offset_from_left_edge": 0.02338,
|
|
69
|
+
"offset_from_top_edge": 0.02474,
|
|
70
|
+
"z_reference": "top surface of plate"
|
|
71
|
+
},
|
|
72
|
+
"notes": "The sixteen wells of this definition are the sixteen imaging regions of four Xona XC-SF150-X4 chips loaded in the Ramona 4-pocket, 27mm-pitch holder (Ramona_Xona_chip_holder_4_well_plate): four culture units (A-D) on each of four chips, each well covering one unit's microgroove barrier between its two compartment channels. It is the file to select when four chips are loaded in that holder, and is the 27mm-pitch counterpart of Xona_XC-SF150-X4_in_Ramona_chip_holder_12_well_plate; everything about the chip and the imaging region (size 4.00 x 1.00mm, 80 um depth, 150 um COC film, and how each was sourced or scaled) is as recorded in that file and in Xona_XC-SF150-X4_4_well_plate. Requested 2026-11-17, issue #66. GRID: 4 rows x 4 columns. The chips lie with their 75.50mm axis along the plate's width, so the units step in y (rows, row_pitch 12.00mm, Xona's printed unit pitch) and the chips step in x (columns, column_pitch 27.00mm, the holder's pocket pitch printed on its drawing, and intended per the requester). 'pitch' carries the smaller, 12.00mm, as the schema suggests; a reader that knows only 'pitch' places the columns 12.00mm apart and so places this plate wrong. Columns at the pocket centres x = 23.38, 50.38, 77.38 and 104.38mm; rows at y = 24.74, 36.74, 48.74 and 60.74mm (42.74 -/+ 6.00 and 18.00), the centres of the holder's imaging windows. A1 is the unit-A barrier of the left-hand chip. The wells span x 21.38-106.38mm and y 24.24-61.24mm, inside the pockets. THE HOLDER, from Ramona's dimension drawing 'Xona Chip Holders - 3x and 4x Dimensions' and STL 'Xona_Holder_4x27mm.stl' of 2026-11-17 (internal, on file at Ramona; see Ramona_Xona_chip_holder_4_well_plate's notes, including its 2026-11-17 CORRECTION: the holder was rebuilt from that newer set at the requester's request and no value changed): footprint 127.76 x 85.48mm, skirt 6.00mm high, body inset 1.60mm to an 8.00mm top with one 4.50mm chamfer at the A1 corner (A1 at the chamfered top-left corner, as the drawing marks it), pockets 25.80 x 75.80mm with 0.30mm clearance round the chip, floor ledge at z = 1.50mm. From the CAD, the chip's film rests on the pocket floor ledge 1.50mm above the resting plane, so the film's underside is at 1.50mm and the sample sits at 1.65mm (1.50mm + the 150 um film). Those are NOT written as bottom_elevation and floor_height: with 'depth' the chip's 80 um channel height and 'height' the holder's 8.00mm top, readers that take a well's top at the plate's top would place the floor at 7.92mm, and the two would contradict each other. Recording them waits on a decision about which height a chips-loaded definition should carry. 'height' 8.00mm is the holder's top face; the chip's overall thickness is not published, so whether its reservoir bosses stand above 8.00mm is not known. The 27mm pitch is not a multiple of the MCAM's 18mm micro-camera pitch, so the four chips do not sit at the same position under a camera column, unlike the 36mm holder."
|
|
73
|
+
}
|
|
@@ -58,6 +58,7 @@ labware/definitions/Mimetas_4004-400-B_384_well_plate.json
|
|
|
58
58
|
labware/definitions/Mimetas_6401-400-B_384_well_plate.json
|
|
59
59
|
labware/definitions/Mimetas_6405-400-B_384_well_plate.json
|
|
60
60
|
labware/definitions/Ramona_Xona_chip_holder_3_well_plate.json
|
|
61
|
+
labware/definitions/Ramona_Xona_chip_holder_4_well_plate.json
|
|
61
62
|
labware/definitions/Ramona_full_SBS_plate_scan_1_well_plate.json
|
|
62
63
|
labware/definitions/Ramona_petri_dish_insert_30_mm.json
|
|
63
64
|
labware/definitions/Ramona_petri_dish_insert_35_mm.json
|
|
@@ -88,7 +89,9 @@ labware/definitions/Thermo_nunc_150628_12_well_plate.json
|
|
|
88
89
|
labware/definitions/Thermo_nunc_165218_1_well_plate.json
|
|
89
90
|
labware/definitions/Thermo_nunc_165305_96_well_plate.json
|
|
90
91
|
labware/definitions/Thermo_nunc_167008_96_well_plate.json
|
|
92
|
+
labware/definitions/Watson_196-96FIS_96_well_plate.json
|
|
91
93
|
labware/definitions/Watson_bio_24_well_plate.json
|
|
92
94
|
labware/definitions/Xona_XC-SF150-X4_4_well_plate.json
|
|
93
95
|
labware/definitions/Xona_XC-SF150-X4_in_Ramona_chip_holder_12_well_plate.json
|
|
96
|
+
labware/definitions/Xona_XC-SF150-X4_in_Ramona_chip_holder_16_well_plate.json
|
|
94
97
|
tests/test_labware.py
|
|
@@ -711,6 +711,13 @@ def test_physical_constraints_assumptions() -> None:
|
|
|
711
711
|
('Corning_costar_12_well_plate.json', 'Corning Costar 12 well', 12, 3, 4),
|
|
712
712
|
('Corning_costar_24_well_plate.json', 'Corning Costar 24 well', 24, 4, 6),
|
|
713
713
|
('Watson_bio_24_well_plate.json', 'Watson Bio 24 well', 24, 4, 6),
|
|
714
|
+
(
|
|
715
|
+
'Watson_196-96FIS_96_well_plate.json',
|
|
716
|
+
'Watson Bio Chimney-well 196-96FIS 96 well',
|
|
717
|
+
96,
|
|
718
|
+
8,
|
|
719
|
+
12,
|
|
720
|
+
),
|
|
714
721
|
('TPP_92412_12_well_plate.json', 'TPP 92412 12 well', 12, 3, 4),
|
|
715
722
|
('Corning_3599_96_well_plate.json', 'Corning 3599 96 well', 96, 8, 12),
|
|
716
723
|
('Corning_3610_96_well_plate.json', 'Corning 3610 96 well', 96, 8, 12),
|
|
@@ -1078,6 +1085,20 @@ def test_physical_constraints_assumptions() -> None:
|
|
|
1078
1085
|
4,
|
|
1079
1086
|
3,
|
|
1080
1087
|
),
|
|
1088
|
+
(
|
|
1089
|
+
'Ramona_Xona_chip_holder_4_well_plate.json',
|
|
1090
|
+
'Ramona Xona Chip Holder 4 well',
|
|
1091
|
+
4,
|
|
1092
|
+
1,
|
|
1093
|
+
4,
|
|
1094
|
+
),
|
|
1095
|
+
(
|
|
1096
|
+
'Xona_XC-SF150-X4_in_Ramona_chip_holder_16_well_plate.json',
|
|
1097
|
+
'Xona XC-SF150-X4 in Ramona Chip Holder 16 well',
|
|
1098
|
+
16,
|
|
1099
|
+
4,
|
|
1100
|
+
4,
|
|
1101
|
+
),
|
|
1081
1102
|
],
|
|
1082
1103
|
)
|
|
1083
1104
|
def test_plate_definition_files_can_be_loaded(
|
|
@@ -1,37 +0,0 @@
|
|
|
1
|
-
{
|
|
2
|
-
"$schema": "https://raw.githubusercontent.com/ramonaoptics/labware/main/labware/labware.v1.schema.json",
|
|
3
|
-
"name": "Ramona Xona Chip Holder 3 well",
|
|
4
|
-
"number_of_wells": 3,
|
|
5
|
-
"manufacturer": "Ramona Optics",
|
|
6
|
-
"author": "Ramona Optics",
|
|
7
|
-
"last_updated": "2026-10-16T00:00:00Z",
|
|
8
|
-
"part_number": "Xona X4 chip holder, 3 slide, SBS footprint",
|
|
9
|
-
"web_reference": "https://docs.ramonaoptics.com/hardware/mcam_inserts.html",
|
|
10
|
-
"applications": [
|
|
11
|
-
"organ-on-chip",
|
|
12
|
-
"imaging"
|
|
13
|
-
],
|
|
14
|
-
"outer_plate_dimensions": {
|
|
15
|
-
"length": 0.12776,
|
|
16
|
-
"width": 0.08548,
|
|
17
|
-
"height": 0.01435
|
|
18
|
-
},
|
|
19
|
-
"well_dimensions": {
|
|
20
|
-
"pitch": 0.036,
|
|
21
|
-
"rows": 1,
|
|
22
|
-
"columns": 3,
|
|
23
|
-
"shape": "rectangle",
|
|
24
|
-
"diameter": 0.0255,
|
|
25
|
-
"width": 0.0255,
|
|
26
|
-
"height": 0.0755,
|
|
27
|
-
"depth": 0.001,
|
|
28
|
-
"bottom_shape": "flat"
|
|
29
|
-
},
|
|
30
|
-
"alignment_reference": {
|
|
31
|
-
"origin_reference": "A1 well center",
|
|
32
|
-
"offset_from_left_edge": 0.02788,
|
|
33
|
-
"offset_from_top_edge": 0.04274,
|
|
34
|
-
"z_reference": "top surface of plate"
|
|
35
|
-
},
|
|
36
|
-
"notes": "The three wells of this definition are the three chip pockets of the holder, empty: A1 is the leftmost pocket. NOT A CATALOGUE PLATE. This is a Ramona Optics fixture: an SBS-footprint holder that carries three Xona XonaChip X4 chips (75.50 x 25.50mm, slide format) so that they can be driven as one plate. Xona themselves describe a four-chip arrangement - 'these chips (the size of standard microscope slides) can be combined in a 4-slide plate holder to yield sixteen (16) sample units' - but that is Xona's own tray, not this holder: Ramona's carries three because the pockets are spaced to the MCAM's 18mm micro-camera pitch (see CORRECTION below), and only three 36mm steps fit the SBS footprint. No drawing of the holder exists yet; the #team_vireo thread the request cites discusses making 'a stand-in stand that we make here'. \n\nREQUESTED, and therefore exact by definition rather than sourced: the 127.76 x 85.48mm ANSI/SLAS footprint with a standard skirt; three rectangular pockets of 25.50 x 75.50mm plus a small clearance, long axis along the plate's width; pocket centres 36mm apart in x at 27.88, 63.88 and 99.88mm, which is twice the MCAM's 18mm micro-camera pitch so every chip sits under the same camera column; and the pocket centre line at y = 42.74mm. Those three x values are symmetric about 63.88mm = 127.76 / 2, and 42.74 = 85.48 / 2, so the block of pockets is centred on the plate, as the request says. GEOMETRY CHECK: the pockets span x 15.13-40.63, 51.13-76.63 and 87.13-112.63mm, leaving a 10.50mm rib between neighbouring pockets and 15.13mm of plate at each end, and y 4.99-80.49mm, leaving 4.99mm at each side. Nothing overruns the footprint. \n\nCORRECTION, 2026-10-15, applied on this branch before merge. The requester (Slack UT35U0XPX, the originator of the request) followed up: 'The micro-camera pitch is 18 mm, not 9 mm.' The first version of this file followed their original message, which said the MCAM micro-camera pitch was 9mm and therefore put four pockets 27mm apart (3 x 9mm) at x = 23.38, 50.38, 77.38 and 104.38mm. That is superseded: the pitch is 18mm, so the pockets are 36mm apart (2 x 18mm) and three of them fit the SBS footprint instead of four. Both values are recorded here deliberately - the 27mm/9mm figures are what the vendor-independent original request asked for, the 36mm/18mm figures are the corrected instrument geometry, and the corrected ones are what this file implements. There is no vendor drawing of this holder for either value to contradict: it is a Ramona fixture and the requester is the authority on both the holder and the instrument it is aligned to. The correction is self-consistent in a way the original was not: within a chip the four culture units A-D span 3 x 12.00 = 36.00mm, exactly the corrected pocket spacing, so the units line up with the micro-cameras along the plate's length as well as the chips doing so. \n\nPOCKET CLEARANCE: the request says '25.50 x 75.50 mm plus a small clearance' and does not give the clearance, so the pockets are recorded at the chip's nominal 25.50 x 75.50mm and the clearance is left out rather than invented. A machined holder will be slightly larger; the chip can then sit off centre in its pocket by half the clearance, which is the dominant positioning error of this fixture and is NOT captured by any field in this file. \n\nNOT SPECIFIED BY ANYONE, recorded here as provisional values that must be replaced from the holder's drawing before it is made, and listed as open questions on the request issue: (a) outer_plate_dimensions.height 14.35mm is the ANSI/SLAS 2-2004 microplate height, used because the request says only 'SBS-footprint ... with standard skirt'; (b) the pocket depth, recorded as 1.0mm so that a chip of the inferred 1.0mm thickness sits flush with the holder's top face - it is a consequence of the chip thickness, which Xona does not publish either; (c) the holder's material and colour, left out entirely (no bottom_material, wall_material, bottom_color or wall_color), since the holder may be machined aluminium, 3D printed plastic or acrylic and that decides whether it can be imaged through at all; (d) whether each pocket is a blind pocket or a through-hole, which decides whether the chips can be used on a transmitted-light instrument. The skirt keys are left at the schema's documented defaults, which are the ANSI/SLAS standard skirt the request asked for. The chip that goes in a pocket is Xona_XC-SF150-X4_4_well_plate.json, and the two together are Xona_XC-SF150-X4_in_Ramona_chip_holder_12_well_plate.json, which is the file to use for imaging; that file was renamed from ..._3_well_plate.json on 2026-10-16 when row_pitch and column_pitch let its twelve imaging regions be written as one 4 x 3 grid instead of three strips. This file is unchanged by that: its wells are the three pockets, one axis, one pitch. CHIP HEIGHT vs PLATE THICKNESS, per the requester's 2026-10-15 follow-up. The 1.00mm figure is kept, still provisional: the requester confirms that the purchasing link in #team_vireo carries no thickness (it is the same plan view already used here), and that Xona's product page, drawings and FAQ give none either, so there is nothing to replace the ISO 8037-1 slide inference with yet. But 1.00mm is the thickness of the flat slide plate ONLY. Xona's product photographs show the O6.0 reservoirs and O2.0 loading ports standing up from that plate as raised bosses, so the chip's overall height is MORE than 1.00mm by an unmeasured amount. Anything that depends on total height rather than on the optical path - pocket depth, lid or tray clearance, a chip sitting flush - must not assume 1.00mm. A caliper measurement of a chip in hand is to follow and will settle both numbers. \n\nUse 'pitch' and origin reference to compute all well centers."
|
|
37
|
-
}
|
|
@@ -1,50 +0,0 @@
|
|
|
1
|
-
{
|
|
2
|
-
"$schema": "https://raw.githubusercontent.com/ramonaoptics/labware/main/labware/labware.v1.schema.json",
|
|
3
|
-
"name": "Xona XC-SF150-X4 in Ramona Chip Holder 12 well",
|
|
4
|
-
"number_of_wells": 12,
|
|
5
|
-
"manufacturer": "Ramona Optics",
|
|
6
|
-
"author": "Ramona Optics",
|
|
7
|
-
"last_updated": "2026-10-16T00:00:00Z",
|
|
8
|
-
"part_number": "XC-SF150-X4 in Ramona Xona X4 chip holder",
|
|
9
|
-
"web_reference": "https://xonamicrofluidics.com/product/xc-sf150-x4/",
|
|
10
|
-
"drawing_reference": "https://xonamicrofluidics.com/wp-content/uploads/2023/02/XC-SF150-x4-InnerDim.png",
|
|
11
|
-
"applications": [
|
|
12
|
-
"organ-on-chip",
|
|
13
|
-
"neural",
|
|
14
|
-
"primary cells",
|
|
15
|
-
"co-culture",
|
|
16
|
-
"cell migration",
|
|
17
|
-
"imaging",
|
|
18
|
-
"fluorescence"
|
|
19
|
-
],
|
|
20
|
-
"outer_plate_dimensions": {
|
|
21
|
-
"length": 0.12776,
|
|
22
|
-
"width": 0.08548,
|
|
23
|
-
"height": 0.01435
|
|
24
|
-
},
|
|
25
|
-
"well_dimensions": {
|
|
26
|
-
"pitch": 0.012,
|
|
27
|
-
"row_pitch": 0.012,
|
|
28
|
-
"column_pitch": 0.036,
|
|
29
|
-
"rows": 4,
|
|
30
|
-
"columns": 3,
|
|
31
|
-
"shape": "rectangle",
|
|
32
|
-
"diameter": 0.001,
|
|
33
|
-
"width": 0.004,
|
|
34
|
-
"height": 0.001,
|
|
35
|
-
"depth": 8e-05,
|
|
36
|
-
"bottom_shape": "flat",
|
|
37
|
-
"bottom_color": "clear",
|
|
38
|
-
"bottom_material": "cyclo_olefin",
|
|
39
|
-
"bottom_thickness": 0.00015,
|
|
40
|
-
"wall_material": "cyclo_olefin",
|
|
41
|
-
"wall_color": "clear"
|
|
42
|
-
},
|
|
43
|
-
"alignment_reference": {
|
|
44
|
-
"origin_reference": "A1 well center",
|
|
45
|
-
"offset_from_left_edge": 0.02788,
|
|
46
|
-
"offset_from_top_edge": 0.02474,
|
|
47
|
-
"z_reference": "top surface of plate"
|
|
48
|
-
},
|
|
49
|
-
"notes": "The twelve wells of this definition are the twelve imaging regions of three Xona XC-SF150-X4 chips loaded in the Ramona holder: four culture units (A-D) on each of three chips, each well covering one unit's microgroove barrier between its two compartment channels. It is the file to select when three chips are loaded in the holder. \n TWELVE WELLS ON A RECTANGULAR LATTICE, and what this replaced. The twelve imaging regions do not sit on a square lattice: the four units within a chip are 12.00mm apart along the plate's width, and the chips are 36.00mm apart along its length. Until 2026-10-16 the schema had a single 'pitch' shared by both axes, so this grid could not be written, and this file took the request's own fallback: 1 row x 3 columns on the 36.00mm chip pitch, each well a 4.00 x 37.00mm strip spanning one chip's four barriers A-D, three addressable wells A1-A3. That is SUPERSEDED. labware now has row_pitch and column_pitch (labware/schema.py, WellDimensions; merged to main in PR #27), so the real grid is written directly: 4 rows x 3 columns, row_pitch 12.00mm, column_pitch 36.00mm, one well per imaging region, twelve wells A1-A3 through D1-D3. Each well is the 4.00 x 1.00mm imaging rectangle of the chip-only file rather than a 37.00mm strip, so a scan covers the twelve regions and not the 11.00mm of chip between them. 'pitch' is kept, as the schema requires, and carries the SMALLER of the two (12.00mm), which is what the schema suggests so that a reader which does not know the new keys still places every well inside the plate's real grid. A READER THAT KNOWS ONLY 'pitch' PLACES THIS PLATE WRONG: it puts the three columns 12.00mm apart instead of 36.00mm, so the two right-hand chips' wells land on the first chip and on the holder's ribs. This definition is only correct for a reader that reads row_pitch and column_pitch. The labware plate viewer reads both as of 2026-10-16 (see the RENDERING correction below); python-owl's acquisition path still reads 'pitch' alone in every release up to 0.19.639, so this plate is only scanned correctly once that reads the two keys as well. \n GEOMETRY. From the request and confirmed against the chip drawing: in the holder the chips lie with their 75.50mm axis along the plate's 85.48mm width, so the four units of a chip step in y (the rows) and the chips step in x (the columns). The unit centres are at y = 24.74, 36.74, 48.74 and 60.74mm - A at 42.74 - 3 x 12.00 / 2 = 24.74 - and the chip columns at the pocket centres x = 27.88, 63.88 and 99.88mm. A1 is therefore the unit A barrier of the left-hand chip, at 27.88mm from the left edge and 24.74mm from the top edge. Both are centred: 27.88 + 2 x 36.00 = 99.88 = 127.76 - 27.88, and 24.74 + 3 x 12.00 = 60.74 = 85.48 - 24.74. Each well is 4.00mm across the barriers (x, the plate's length) by 1.00mm along the channels (y, the plate's width), as in the chip-only file; 'diameter' repeats the shorter side, 1.00mm. The twelve wells span x 25.88-101.88mm and y 24.24-61.24mm, inside the pockets' x 15.13-112.63mm and y 4.99-80.49mm, so nothing overruns a pocket, let alone the footprint. \n\nTHE HOLDER. NOT A CATALOGUE PLATE. This is a Ramona Optics fixture: an SBS-footprint holder that carries three Xona XonaChip X4 chips (75.50 x 25.50mm, slide format) so that they can be driven as one plate. Xona themselves describe a four-chip arrangement - 'these chips (the size of standard microscope slides) can be combined in a 4-slide plate holder to yield sixteen (16) sample units' - but that is Xona's own tray, not this holder: Ramona's carries three because the pockets are spaced to the MCAM's 18mm micro-camera pitch (see CORRECTION below), and only three 36mm steps fit the SBS footprint. No drawing of the holder exists yet; the #team_vireo thread the request cites discusses making 'a stand-in stand that we make here'. \n\nREQUESTED, and therefore exact by definition rather than sourced: the 127.76 x 85.48mm ANSI/SLAS footprint with a standard skirt; three rectangular pockets of 25.50 x 75.50mm plus a small clearance, long axis along the plate's width; pocket centres 36mm apart in x at 27.88, 63.88 and 99.88mm, which is twice the MCAM's 18mm micro-camera pitch so every chip sits under the same camera column; and the pocket centre line at y = 42.74mm. Those three x values are symmetric about 63.88mm = 127.76 / 2, and 42.74 = 85.48 / 2, so the block of pockets is centred on the plate, as the request says. GEOMETRY CHECK: the pockets span x 15.13-40.63, 51.13-76.63 and 87.13-112.63mm, leaving a 10.50mm rib between neighbouring pockets and 15.13mm of plate at each end, and y 4.99-80.49mm, leaving 4.99mm at each side. Nothing overruns the footprint. \n\nCORRECTION, 2026-10-15, applied on this branch before merge. The requester (Slack UT35U0XPX, the originator of the request) followed up: 'The micro-camera pitch is 18 mm, not 9 mm.' The first version of this file followed their original message, which said the MCAM micro-camera pitch was 9mm and therefore put four pockets 27mm apart (3 x 9mm) at x = 23.38, 50.38, 77.38 and 104.38mm. That is superseded: the pitch is 18mm, so the pockets are 36mm apart (2 x 18mm) and three of them fit the SBS footprint instead of four. Both values are recorded here deliberately - the 27mm/9mm figures are what the vendor-independent original request asked for, the 36mm/18mm figures are the corrected instrument geometry, and the corrected ones are what this file implements. There is no vendor drawing of this holder for either value to contradict: it is a Ramona fixture and the requester is the authority on both the holder and the instrument it is aligned to. The correction is self-consistent in a way the original was not: within a chip the four culture units A-D span 3 x 12.00 = 36.00mm, exactly the corrected pocket spacing, so the units line up with the micro-cameras along the plate's length as well as the chips doing so. \n\nPOCKET CLEARANCE: the request says '25.50 x 75.50 mm plus a small clearance' and does not give the clearance, so the pockets are recorded at the chip's nominal 25.50 x 75.50mm and the clearance is left out rather than invented. A machined holder will be slightly larger; the chip can then sit off centre in its pocket by half the clearance, which is the dominant positioning error of this fixture and is NOT captured by any field in this file. \n\nNOT SPECIFIED BY ANYONE, recorded here as provisional values that must be replaced from the holder's drawing before it is made, and listed as open questions on the request issue: (a) outer_plate_dimensions.height 14.35mm is the ANSI/SLAS 2-2004 microplate height, used because the request says only 'SBS-footprint ... with standard skirt'; (b) the pocket depth, recorded as 1.0mm so that a chip of the inferred 1.0mm thickness sits flush with the holder's top face - it is a consequence of the chip thickness, which Xona does not publish either; (c) the holder's material and colour, left out entirely (no bottom_material, wall_material, bottom_color or wall_color), since the holder may be machined aluminium, 3D printed plastic or acrylic and that decides whether it can be imaged through at all; (d) whether each pocket is a blind pocket or a through-hole, which decides whether the chips can be used on a transmitted-light instrument. The skirt keys are left at the schema's documented defaults, which are the ANSI/SLAS standard skirt the request asked for.\n\nTHE CHIP. CONTROLLING DOCUMENTS, both published by Xona Microfluidics on their XC-SF150-X4 product page. (1) The dimensioned plan drawing 'XC-SF150-x4-InnerDim.png' (drawing_reference), which prints, as callouts: 75.50mm overall length, 25.50mm overall width, 19.75mm from the end of the chip to the centre line of unit A, 12.00mm unit-to-unit pitch, 10.00mm between the centres of the two large wells of a unit, 7.00mm between the centres of the two small ports of a unit, O6.0 for the large wells and O2.0 for the small ports. A companion drawing 'XC-SF150-x4-OuterDim.png' repeats 75.50 x 25.50mm, and 'XC-SF150-x4-UnitView.png' is an undimensioned enlarged plan of one unit. The drawings carry no revision or date; they were uploaded in 2023-02 per their URL. (2) The vendor's specification text, spread over the product page, the XONACHIPS page, the FAQ page and the 'Introducing XonaChips' / 'Introducing the X4 XonaChip' posts: '(4) compartmentalized culture units, each with 150 um wide microgroove barriers'; 'Each unit contains (18) microgrooves connecting the compartments'; 'Each microgroove cross-section for all XonaChips is approximately 7 um x 7 um'; 'Main channel heights are approximately 80 um'; 'a smaller cell loading port approximately 2 mm in diameter'; 'XonaChips are made of cyclic olefin copolymer (COC)'; 'The XonaChip consists of a molded COC top bonded to a thin optically transparent 150 um thick COC film'; 'The outside dimensions of the X4 chip are the same as a standard microscope slide'; 'Size: 75 mm x 25 mm'. Where the catalogue text's rounded '75 mm x 25 mm' and the drawing's 75.50 x 25.50mm disagree, the drawing is followed. \n\nMATERIAL, answering the request's question directly: this chip is NOT PDMS on a glass coverslip. Xona's FAQ separates the two product lines - 'The silicone devices are made of poly(dimethylsiloxane) (PDMS) and XonaChips are made of cyclic olefin copolymer (COC)'. XC-SF150-X4 is a XonaChip, an injection-moulded COC top bonded to a 150 um COC film, so bottom_material and wall_material are cyclo_olefin and bottom_thickness is the published 150 um film. The PDMS part with the same barrier is the separate SF150x2 'Small Footprint Silicone Device', which is a different part and a different size (about 28 x 18 mm). No refractive index is published for the film and none is recorded; COC is typically about 1.53 at 589 nm, which is NOT taken from a Xona document and is mentioned here for orientation only. \n\nTHE IMAGING REGION, and how its size was obtained. The request asks for a well that covers the microgroove barrier between the two compartment channels at the centre of a unit, sized from Xona's published specs. Xona publishes the barrier length (150 um) but publishes NO channel width and NO channel length for the X4 unit. The '1.5 mm x 7 mm x 0.060 mm (W x L x H) main channels' and '0.01 mm x 0.005 mm microgrooves' figures that circulate for XonaChips come from the JoVE protocol 'Use of Pre-Assembled Plastic Microfluidic Chips for Compartmentalizing Primary Murine Neurons' (doi:10.3791/58421), which describes the 2-compartment XC150 / XC450 / XC900 chips, not this small-footprint 4-unit chip, and they also contradict Xona's own site (80 um channel height, 7 x 7 um microgrooves). They were therefore NOT used. \nThe region's size across the barrier is DERIVED from two printed callouts only: the two large wells of a unit are 10.00mm apart and are O6.0, so the open fluidic region between their edges is 10.00 - 6.00 = 4.00mm, centred on the unit's centre. The region's size along the channels is SCALED off the published UnitView drawing, assumed to scale: at 1600 x 1280 px the two O6.0 circles measure 420 px across and their centres 707 px apart, giving 70.0 px/mm and 70.7 px/mm in x, and the two O2.0 port centres measure 494 px apart, giving 70.6 px/mm in y - two independent calibrations per axis agreeing to 1% and the two axes agreeing to 0.2%. On that scale the microgroove bank, drawn as the hatched strip at the unit's centre, spans 71 px = 1.00mm, and the channel neck either side of it spans 71-80 px = 1.00-1.13mm. The well is therefore recorded as 4.00mm across the barrier by 1.00mm along the channels, centred on the unit's centre. Uncertainty on the 1.00mm value is about +/-0.1mm: the drawing's line weight is 4 px (0.06mm) and the two measurements of the neck differ by 0.13mm. It is corroborated by the vendor's own text: 18 microgrooves of 7 um width spread over 1.00mm is a 56 um groove pitch, which matches the drawn hatching. The 150 um barrier itself measures 15 px = 0.21mm on the same calibration, which is the printed 150 um plus two line widths, so the drawing is consistent with its own callout. \n\nNOT PUBLISHED BY XONA, and therefore not written as a vendor number anywhere in this file: overall chip thickness; well and port depths; reservoir working volumes; any tolerance; the chip's corner radius; sterility; surface treatment of the channels (the chips ship with a separate 'XC Pre-Coat' tube, which is a reagent, not a moulded-in treatment).\n\nZ, and what is not recorded. bottom_thickness 150 um is the chip's COC film, the layer the objective looks through. bottom_elevation and floor_height are NOT recorded: they would be the pocket floor's height above the holder's resting plane plus the film, and the holder's section does not exist yet. 'depth' 80 um is the chip's published channel height, as in the chip-only file. CHIP HEIGHT vs PLATE THICKNESS, per the requester's 2026-10-15 follow-up. The 1.00mm figure is kept, still provisional: the requester confirms that the purchasing link in #team_vireo carries no thickness (it is the same plan view already used here), and that Xona's product page, drawings and FAQ give none either, so there is nothing to replace the ISO 8037-1 slide inference with yet. But 1.00mm is the thickness of the flat slide plate ONLY. Xona's product photographs show the O6.0 reservoirs and O2.0 loading ports standing up from that plate as raised bosses, so the chip's overall height is MORE than 1.00mm by an unmeasured amount. Anything that depends on total height rather than on the optical path - pocket depth, lid or tray clearance, a chip sitting flush - must not assume 1.00mm. A caliper measurement of a chip in hand is to follow and will settle both numbers. \n CORRECTION, 2026-10-16, applied on this branch before merge, the second correction from the same requester. Slack UT35U0XPX, who made the original request, wrote: 'I have just enabled different pitch in rows and columns. please use that to create a more accurate schema.' The evidence is the schema itself: row_pitch and column_pitch are on labware main as of PR #27 (commit a204bc5, 2026-10-15). No vendor document is contradicted - the chip's 12.00mm unit pitch is Xona's printed callout and is unchanged, the holder's 36.00mm chip pitch is the requester's own corrected figure and is unchanged; what changed is only that the two can now be written as one grid instead of being collapsed into three strips. Superseded values recorded above. The chip-only and empty-holder files are untouched: each has a single axis of wells, so neither has two pitches to record. \n \n RENDERING, 2026-10-16, no dimension changed. The requester (Slack UT35U0XPX, who made the original request) asked for the renderer to be fixed rather than the numbers: 'please update the render code as well to make the renders look correct'. The panels published with this branch were drawn by python-owl's labware plate viewer, which read 'pitch' alone and therefore drew this plate's three columns 12.00mm apart, and drew the empty holder's 75.50mm pockets clamped to 34.92mm, its single row of wells having no neighbour to leave a wall to. The viewer now carries a spacing per axis and clamps a well to its pitch only along an axis that holds more than one well; it was checked against all 75 definitions in this repository and the well centres, well sizes and warnings of the other 73 are unchanged. That change is in python-owl (examples_internal/labware_plate_viewer.py), NOT in this repository, and it is not merged there yet. NO VALUE IN THIS FILE CHANGED: the earlier panels were wrong about a correct file, which is why the only thing the correction touched was the code that draws them. Use row_pitch, column_pitch and the origin reference to compute all well centers; 'pitch' alone is not enough for this plate."
|
|
50
|
-
}
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
{labware-0.2.4 → labware-0.2.6}/labware/definitions/Ramona_full_SBS_plate_scan_1_well_plate.json
RENAMED
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|