labunits 0.1.0__tar.gz
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- labunits-0.1.0/LICENSE.md +9 -0
- labunits-0.1.0/PKG-INFO +25 -0
- labunits-0.1.0/README.md +14 -0
- labunits-0.1.0/pyproject.toml +25 -0
- labunits-0.1.0/setup.cfg +4 -0
- labunits-0.1.0/src/labunits/__init__.py +0 -0
- labunits-0.1.0/src/labunits/converters.py +116 -0
- labunits-0.1.0/src/labunits.egg-info/PKG-INFO +25 -0
- labunits-0.1.0/src/labunits.egg-info/SOURCES.txt +11 -0
- labunits-0.1.0/src/labunits.egg-info/dependency_links.txt +1 -0
- labunits-0.1.0/src/labunits.egg-info/top_level.txt +1 -0
- labunits-0.1.0/tests/test_converters.py +131 -0
- labunits-0.1.0/tests/test_data_integration.py +81 -0
|
@@ -0,0 +1,9 @@
|
|
|
1
|
+
# The MIT License (MIT)
|
|
2
|
+
|
|
3
|
+
Copyright © 2025 <Christian González>
|
|
4
|
+
|
|
5
|
+
Permission is hereby granted, free of charge, to any person obtaining a copy of this software and associated documentation files (the “Software”), to deal in the Software without restriction, including without limitation the rights to use, copy, modify, merge, publish, distribute, sublicense, and/or sell copies of the Software, and to permit persons to whom the Software is furnished to do so, subject to the following conditions:
|
|
6
|
+
|
|
7
|
+
The above copyright notice and this permission notice shall be included in all copies or substantial portions of the Software.
|
|
8
|
+
|
|
9
|
+
THE SOFTWARE IS PROVIDED “AS IS”, WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.
|
labunits-0.1.0/PKG-INFO
ADDED
|
@@ -0,0 +1,25 @@
|
|
|
1
|
+
Metadata-Version: 2.4
|
|
2
|
+
Name: labunits
|
|
3
|
+
Version: 0.1.0
|
|
4
|
+
Summary: Convert laboratory units between mmol/l und mg/dl based on the molar mass of the unit.
|
|
5
|
+
Author-email: Christian Gonzalez <office@nerdocs.at>
|
|
6
|
+
Project-URL: Homepage, https://github.com/nerdocs/labunits
|
|
7
|
+
Requires-Python: >=3.10
|
|
8
|
+
Description-Content-Type: text/markdown
|
|
9
|
+
License-File: LICENSE.md
|
|
10
|
+
Dynamic: license-file
|
|
11
|
+
|
|
12
|
+
# Labunits
|
|
13
|
+
|
|
14
|
+
|
|
15
|
+
This is a simple python library for laboratory units, and to convert between them.
|
|
16
|
+
|
|
17
|
+
|
|
18
|
+
### Why another library with this content?
|
|
19
|
+
|
|
20
|
+
Oh - just because - there IS NONE. I couldn't believe that.
|
|
21
|
+
|
|
22
|
+
|
|
23
|
+
### License
|
|
24
|
+
|
|
25
|
+
MIT. Just use it in your project and give credits.
|
labunits-0.1.0/README.md
ADDED
|
@@ -0,0 +1,14 @@
|
|
|
1
|
+
# Labunits
|
|
2
|
+
|
|
3
|
+
|
|
4
|
+
This is a simple python library for laboratory units, and to convert between them.
|
|
5
|
+
|
|
6
|
+
|
|
7
|
+
### Why another library with this content?
|
|
8
|
+
|
|
9
|
+
Oh - just because - there IS NONE. I couldn't believe that.
|
|
10
|
+
|
|
11
|
+
|
|
12
|
+
### License
|
|
13
|
+
|
|
14
|
+
MIT. Just use it in your project and give credits.
|
|
@@ -0,0 +1,25 @@
|
|
|
1
|
+
[build-system]
|
|
2
|
+
requires = ["setuptools>=61.0"]
|
|
3
|
+
build-backend = "setuptools.build_meta"
|
|
4
|
+
|
|
5
|
+
[project]
|
|
6
|
+
name = "labunits"
|
|
7
|
+
version = "0.1.0"
|
|
8
|
+
description = "Convert laboratory units between mmol/l und mg/dl based on the molar mass of the unit."
|
|
9
|
+
authors = [
|
|
10
|
+
{ name="Christian Gonzalez", email="office@nerdocs.at" }
|
|
11
|
+
]
|
|
12
|
+
readme = "README.md"
|
|
13
|
+
license-files = ["LICENSE.md"]
|
|
14
|
+
requires-python = ">=3.10"
|
|
15
|
+
|
|
16
|
+
[project.urls]
|
|
17
|
+
Homepage = "https://github.com/nerdocs/labunits"
|
|
18
|
+
|
|
19
|
+
[dependencies]
|
|
20
|
+
|
|
21
|
+
|
|
22
|
+
[dependency-groups]
|
|
23
|
+
test = ["pytest", "ruff"]
|
|
24
|
+
dev = ["beautifulsoup4","build", "thefuzz", "pydantic", "ruff", "black"]
|
|
25
|
+
|
labunits-0.1.0/setup.cfg
ADDED
|
File without changes
|
|
@@ -0,0 +1,116 @@
|
|
|
1
|
+
import json
|
|
2
|
+
import math
|
|
3
|
+
from pathlib import Path
|
|
4
|
+
|
|
5
|
+
_analytes_data = {}
|
|
6
|
+
|
|
7
|
+
type LoincNum = str
|
|
8
|
+
|
|
9
|
+
|
|
10
|
+
def _load_data() -> dict:
|
|
11
|
+
"""
|
|
12
|
+
Load data from the 'data' directory.
|
|
13
|
+
|
|
14
|
+
Returns:
|
|
15
|
+
dict: Data in the format {'analyte': {'value': float, 'units': str}}
|
|
16
|
+
"""
|
|
17
|
+
global _analytes_data
|
|
18
|
+
# check if data is already loaded
|
|
19
|
+
if _analytes_data:
|
|
20
|
+
return _analytes_data
|
|
21
|
+
|
|
22
|
+
# get data dir of labunits package using Pathlib
|
|
23
|
+
data_dir = Path(__file__).parent / "data"
|
|
24
|
+
|
|
25
|
+
with Path.open(data_dir / "analytes.json", "r") as file:
|
|
26
|
+
_analytes_data = json.load(file)
|
|
27
|
+
|
|
28
|
+
return _analytes_data
|
|
29
|
+
|
|
30
|
+
|
|
31
|
+
def _resolve_analyte_identifier(identifier: str) -> LoincNum:
|
|
32
|
+
"""Resolve various identifiers to LOINC code."""
|
|
33
|
+
data = _load_data()
|
|
34
|
+
|
|
35
|
+
# Direct LOINC lookup
|
|
36
|
+
if identifier in data:
|
|
37
|
+
return identifier
|
|
38
|
+
|
|
39
|
+
# Search by abbreviation or name
|
|
40
|
+
for loinc, info in data.items():
|
|
41
|
+
if ( # FIXME
|
|
42
|
+
info.get("abbreviation", "").lower() == identifier.lower()
|
|
43
|
+
or info.get("name", "").lower() == identifier.lower()
|
|
44
|
+
):
|
|
45
|
+
return loinc
|
|
46
|
+
|
|
47
|
+
raise ValueError(f"Unknown analyte identifier: {identifier}")
|
|
48
|
+
|
|
49
|
+
|
|
50
|
+
def si_unit(analyte: LoincNum | str) -> str:
|
|
51
|
+
"""Returns the SI unit for the given analyte.
|
|
52
|
+
|
|
53
|
+
Examples:
|
|
54
|
+
"mmol/L"
|
|
55
|
+
"µmol/L"
|
|
56
|
+
"""
|
|
57
|
+
loinc = _resolve_analyte_identifier(analyte)
|
|
58
|
+
return _analytes_data[loinc]["si_units"]
|
|
59
|
+
|
|
60
|
+
|
|
61
|
+
def traditional_unit(analyte: LoincNum | str) -> str:
|
|
62
|
+
"""Returns the traditional unit for the given analyte."""
|
|
63
|
+
loinc = _resolve_analyte_identifier(analyte)
|
|
64
|
+
return _analytes_data[loinc]["traditional_units"]
|
|
65
|
+
|
|
66
|
+
|
|
67
|
+
def conversion_factor(analyte: LoincNum | str) -> float:
|
|
68
|
+
"""Returns the conversion factor for the given analyte.
|
|
69
|
+
|
|
70
|
+
Multiply with the factor to convert from traditional to SI, divide by it the
|
|
71
|
+
other way round.
|
|
72
|
+
|
|
73
|
+
Returns:
|
|
74
|
+
float: Conversion factor
|
|
75
|
+
"""
|
|
76
|
+
loinc = _resolve_analyte_identifier(analyte)
|
|
77
|
+
return float(_analytes_data[loinc]["conversion_factor"])
|
|
78
|
+
|
|
79
|
+
|
|
80
|
+
def to_si_unit(analyte: LoincNum | str, value: float) -> float:
|
|
81
|
+
"""
|
|
82
|
+
Convert value to SI unit.
|
|
83
|
+
|
|
84
|
+
Args:
|
|
85
|
+
analyte: LOINC code (preferred), abbreviation, or full name
|
|
86
|
+
value (float): Concentration in traditional units
|
|
87
|
+
Returns:
|
|
88
|
+
float: value in SI units
|
|
89
|
+
"""
|
|
90
|
+
# Normalize to LOINC internally
|
|
91
|
+
loinc = _resolve_analyte_identifier(analyte)
|
|
92
|
+
data = _load_data()
|
|
93
|
+
factor = float(data[loinc]["conversion_factor"])
|
|
94
|
+
|
|
95
|
+
if math.isinf(value) or math.isnan(value):
|
|
96
|
+
return value
|
|
97
|
+
return value * factor
|
|
98
|
+
|
|
99
|
+
|
|
100
|
+
def to_traditional_unit(analyte: str, value: float) -> float:
|
|
101
|
+
"""
|
|
102
|
+
Convert SI to value unit.
|
|
103
|
+
|
|
104
|
+
Args:
|
|
105
|
+
analyte: LOINC code (preferred), abbreviation, or full name
|
|
106
|
+
value (float): Concentration in SI units
|
|
107
|
+
Returns:
|
|
108
|
+
float: value in traditional units
|
|
109
|
+
"""
|
|
110
|
+
loinc = _resolve_analyte_identifier(analyte)
|
|
111
|
+
data = _load_data()
|
|
112
|
+
factor = float(data[loinc]["conversion_factor"])
|
|
113
|
+
|
|
114
|
+
if math.isinf(value) or math.isnan(value):
|
|
115
|
+
return value
|
|
116
|
+
return value / factor
|
|
@@ -0,0 +1,25 @@
|
|
|
1
|
+
Metadata-Version: 2.4
|
|
2
|
+
Name: labunits
|
|
3
|
+
Version: 0.1.0
|
|
4
|
+
Summary: Convert laboratory units between mmol/l und mg/dl based on the molar mass of the unit.
|
|
5
|
+
Author-email: Christian Gonzalez <office@nerdocs.at>
|
|
6
|
+
Project-URL: Homepage, https://github.com/nerdocs/labunits
|
|
7
|
+
Requires-Python: >=3.10
|
|
8
|
+
Description-Content-Type: text/markdown
|
|
9
|
+
License-File: LICENSE.md
|
|
10
|
+
Dynamic: license-file
|
|
11
|
+
|
|
12
|
+
# Labunits
|
|
13
|
+
|
|
14
|
+
|
|
15
|
+
This is a simple python library for laboratory units, and to convert between them.
|
|
16
|
+
|
|
17
|
+
|
|
18
|
+
### Why another library with this content?
|
|
19
|
+
|
|
20
|
+
Oh - just because - there IS NONE. I couldn't believe that.
|
|
21
|
+
|
|
22
|
+
|
|
23
|
+
### License
|
|
24
|
+
|
|
25
|
+
MIT. Just use it in your project and give credits.
|
|
@@ -0,0 +1,11 @@
|
|
|
1
|
+
LICENSE.md
|
|
2
|
+
README.md
|
|
3
|
+
pyproject.toml
|
|
4
|
+
src/labunits/__init__.py
|
|
5
|
+
src/labunits/converters.py
|
|
6
|
+
src/labunits.egg-info/PKG-INFO
|
|
7
|
+
src/labunits.egg-info/SOURCES.txt
|
|
8
|
+
src/labunits.egg-info/dependency_links.txt
|
|
9
|
+
src/labunits.egg-info/top_level.txt
|
|
10
|
+
tests/test_converters.py
|
|
11
|
+
tests/test_data_integration.py
|
|
@@ -0,0 +1 @@
|
|
|
1
|
+
|
|
@@ -0,0 +1 @@
|
|
|
1
|
+
labunits
|
|
@@ -0,0 +1,131 @@
|
|
|
1
|
+
"""Tests for ``labunits.converters``.
|
|
2
|
+
|
|
3
|
+
Function-style tests, no classes. The autouse fixture in ``conftest.py``
|
|
4
|
+
injects ``SAMPLE_ANALYTES`` into the module-level cache so the real JSON
|
|
5
|
+
file is irrelevant here.
|
|
6
|
+
"""
|
|
7
|
+
|
|
8
|
+
import math
|
|
9
|
+
|
|
10
|
+
import pytest
|
|
11
|
+
|
|
12
|
+
from labunits.converters import (
|
|
13
|
+
conversion_factor,
|
|
14
|
+
si_unit,
|
|
15
|
+
to_si_unit,
|
|
16
|
+
to_traditional_unit,
|
|
17
|
+
traditional_unit,
|
|
18
|
+
)
|
|
19
|
+
|
|
20
|
+
|
|
21
|
+
# ---------------------------------------------------------------------------
|
|
22
|
+
# Lookup helpers
|
|
23
|
+
# ---------------------------------------------------------------------------
|
|
24
|
+
|
|
25
|
+
|
|
26
|
+
def test_si_unit_by_loinc():
|
|
27
|
+
assert si_unit("109547-0") == "mmol/L"
|
|
28
|
+
|
|
29
|
+
|
|
30
|
+
def test_traditional_unit_by_loinc():
|
|
31
|
+
assert traditional_unit("109547-0") == "mg/dL"
|
|
32
|
+
|
|
33
|
+
|
|
34
|
+
def test_lookup_by_exact_name():
|
|
35
|
+
assert si_unit("Acetone") == "mmol/L"
|
|
36
|
+
|
|
37
|
+
|
|
38
|
+
def test_lookup_by_lowercase_name():
|
|
39
|
+
assert si_unit("acetone") == "mmol/L"
|
|
40
|
+
|
|
41
|
+
|
|
42
|
+
def test_lookup_by_uppercase_name():
|
|
43
|
+
assert si_unit("ACETONE") == "mmol/L"
|
|
44
|
+
|
|
45
|
+
|
|
46
|
+
def test_unknown_identifier_raises_value_error():
|
|
47
|
+
with pytest.raises(ValueError, match="Unknown analyte identifier"):
|
|
48
|
+
si_unit("definitely-not-a-real-analyte")
|
|
49
|
+
|
|
50
|
+
|
|
51
|
+
# ---------------------------------------------------------------------------
|
|
52
|
+
# conversion_factor
|
|
53
|
+
# ---------------------------------------------------------------------------
|
|
54
|
+
|
|
55
|
+
|
|
56
|
+
def test_conversion_factor_returns_float():
|
|
57
|
+
factor = conversion_factor("109547-0")
|
|
58
|
+
assert isinstance(factor, float)
|
|
59
|
+
assert factor == pytest.approx(0.172)
|
|
60
|
+
|
|
61
|
+
|
|
62
|
+
def test_conversion_factor_for_albumin():
|
|
63
|
+
assert conversion_factor("100158-5") == pytest.approx(10.0)
|
|
64
|
+
|
|
65
|
+
|
|
66
|
+
# ---------------------------------------------------------------------------
|
|
67
|
+
# to_si_unit / to_traditional_unit
|
|
68
|
+
# ---------------------------------------------------------------------------
|
|
69
|
+
|
|
70
|
+
|
|
71
|
+
def test_to_si_unit_acetone():
|
|
72
|
+
# 1.0 mg/dL * 0.172 == 0.172 mmol/L
|
|
73
|
+
assert to_si_unit("109547-0", 1.0) == pytest.approx(0.172)
|
|
74
|
+
|
|
75
|
+
|
|
76
|
+
def test_to_si_unit_albumin():
|
|
77
|
+
# 4.0 g/dL * 10 == 40 g/L
|
|
78
|
+
assert to_si_unit("100158-5", 4.0) == pytest.approx(40.0)
|
|
79
|
+
|
|
80
|
+
|
|
81
|
+
def test_to_traditional_unit_acetone():
|
|
82
|
+
# 0.172 mmol/L / 0.172 == 1.0 mg/dL
|
|
83
|
+
assert to_traditional_unit("109547-0", 0.172) == pytest.approx(1.0)
|
|
84
|
+
|
|
85
|
+
|
|
86
|
+
def test_to_traditional_unit_albumin():
|
|
87
|
+
# 40 g/L / 10 == 4.0 g/dL
|
|
88
|
+
assert to_traditional_unit("100158-5", 40.0) == pytest.approx(4.0)
|
|
89
|
+
|
|
90
|
+
|
|
91
|
+
def test_round_trip_traditional_to_si_to_traditional():
|
|
92
|
+
original = 2.5
|
|
93
|
+
si = to_si_unit("100158-5", original)
|
|
94
|
+
back = to_traditional_unit("100158-5", si)
|
|
95
|
+
assert back == pytest.approx(original)
|
|
96
|
+
|
|
97
|
+
|
|
98
|
+
def test_zero_value_passes_through():
|
|
99
|
+
assert to_si_unit("109547-0", 0.0) == 0.0
|
|
100
|
+
assert to_traditional_unit("109547-0", 0.0) == 0.0
|
|
101
|
+
|
|
102
|
+
|
|
103
|
+
def test_negative_value_is_converted():
|
|
104
|
+
assert to_si_unit("100158-5", -3.0) == pytest.approx(-30.0)
|
|
105
|
+
|
|
106
|
+
|
|
107
|
+
def test_to_si_unit_returns_float():
|
|
108
|
+
assert isinstance(to_si_unit("109547-0", 1.0), float)
|
|
109
|
+
|
|
110
|
+
|
|
111
|
+
# ---------------------------------------------------------------------------
|
|
112
|
+
# Special float values
|
|
113
|
+
# ---------------------------------------------------------------------------
|
|
114
|
+
|
|
115
|
+
|
|
116
|
+
def test_positive_infinity_passes_through():
|
|
117
|
+
assert to_si_unit("109547-0", float("inf")) == float("inf")
|
|
118
|
+
assert to_traditional_unit("109547-0", float("inf")) == float("inf")
|
|
119
|
+
|
|
120
|
+
|
|
121
|
+
def test_negative_infinity_passes_through():
|
|
122
|
+
assert to_si_unit("109547-0", float("-inf")) == float("-inf")
|
|
123
|
+
assert to_traditional_unit("109547-0", float("-inf")) == float("-inf")
|
|
124
|
+
|
|
125
|
+
|
|
126
|
+
def test_nan_passes_through():
|
|
127
|
+
# NaN must propagate, not raise. The current implementation uses
|
|
128
|
+
# ``value in [..., float("nan")]`` which is always False because
|
|
129
|
+
# NaN never compares equal to itself — this test exposes that bug.
|
|
130
|
+
assert math.isnan(to_si_unit("109547-0", float("nan")))
|
|
131
|
+
assert math.isnan(to_traditional_unit("109547-0", float("nan")))
|
|
@@ -0,0 +1,81 @@
|
|
|
1
|
+
"""Integration tests against the real shipped ``analytes.json``.
|
|
2
|
+
|
|
3
|
+
These tests bypass the autouse fixture from ``conftest.py`` so they hit
|
|
4
|
+
the actual data file as the published library would.
|
|
5
|
+
"""
|
|
6
|
+
|
|
7
|
+
import json
|
|
8
|
+
from pathlib import Path
|
|
9
|
+
|
|
10
|
+
import pytest
|
|
11
|
+
|
|
12
|
+
from labunits import converters
|
|
13
|
+
from labunits.converters import (
|
|
14
|
+
conversion_factor,
|
|
15
|
+
si_unit,
|
|
16
|
+
to_si_unit,
|
|
17
|
+
to_traditional_unit,
|
|
18
|
+
traditional_unit,
|
|
19
|
+
)
|
|
20
|
+
|
|
21
|
+
|
|
22
|
+
@pytest.fixture
|
|
23
|
+
def real_data(monkeypatch):
|
|
24
|
+
"""Reset the module cache and force a real load from the shipped JSON."""
|
|
25
|
+
monkeypatch.setattr(converters, "_analytes_data", {})
|
|
26
|
+
yield converters._load_data()
|
|
27
|
+
|
|
28
|
+
|
|
29
|
+
def test_shipped_json_is_valid():
|
|
30
|
+
data_file = Path(converters.__file__).parent / "data" / "analytes.json"
|
|
31
|
+
with data_file.open("r", encoding="utf-8") as f:
|
|
32
|
+
data = json.load(f)
|
|
33
|
+
assert isinstance(data, dict)
|
|
34
|
+
assert len(data) > 0
|
|
35
|
+
|
|
36
|
+
|
|
37
|
+
def test_shipped_entries_have_required_keys(real_data):
|
|
38
|
+
required = {"name", "traditional_units", "si_units", "conversion_factor"}
|
|
39
|
+
missing = [
|
|
40
|
+
loinc for loinc, entry in real_data.items() if not required <= entry.keys()
|
|
41
|
+
]
|
|
42
|
+
assert missing == []
|
|
43
|
+
|
|
44
|
+
|
|
45
|
+
# A few upstream entries (AccessMedicine HTML) ship without a numeric
|
|
46
|
+
# conversion factor — typically when the units are dimensionless or
|
|
47
|
+
# percentage-based and no factor is published. Track them explicitly
|
|
48
|
+
# so genuine regressions stand out.
|
|
49
|
+
KNOWN_NON_NUMERIC_FACTORS = {"27345-8"} # Hemoglobin A2 (% total Hb <-> fraction)
|
|
50
|
+
|
|
51
|
+
|
|
52
|
+
def test_shipped_conversion_factors_are_numeric_when_present(real_data):
|
|
53
|
+
bad = set()
|
|
54
|
+
for loinc, entry in real_data.items():
|
|
55
|
+
factor = entry["conversion_factor"]
|
|
56
|
+
if factor == "":
|
|
57
|
+
continue
|
|
58
|
+
try:
|
|
59
|
+
float(factor)
|
|
60
|
+
except (TypeError, ValueError):
|
|
61
|
+
bad.add(loinc)
|
|
62
|
+
assert bad == set(), f"Non-numeric conversion factors: {bad}"
|
|
63
|
+
|
|
64
|
+
|
|
65
|
+
def test_known_non_numeric_factor_entries_are_still_in_data(real_data):
|
|
66
|
+
# Documents the upstream gap so it's visible. If the source data
|
|
67
|
+
# gets fixed and a factor is added, this test will fail and prompt
|
|
68
|
+
# us to drop the entry from KNOWN_NON_NUMERIC_FACTORS.
|
|
69
|
+
for loinc in KNOWN_NON_NUMERIC_FACTORS:
|
|
70
|
+
assert loinc in real_data
|
|
71
|
+
assert real_data[loinc]["conversion_factor"] == ""
|
|
72
|
+
|
|
73
|
+
|
|
74
|
+
def test_acetone_round_trip_against_real_data(real_data):
|
|
75
|
+
# Acetone (LOINC 109547-0): 1 mg/dL -> 0.172 mmol/L
|
|
76
|
+
assert "109547-0" in real_data
|
|
77
|
+
assert si_unit("109547-0") == "mmol/L"
|
|
78
|
+
assert traditional_unit("109547-0") == "mg/dL"
|
|
79
|
+
assert conversion_factor("109547-0") == pytest.approx(0.172)
|
|
80
|
+
assert to_si_unit("109547-0", 1.0) == pytest.approx(0.172)
|
|
81
|
+
assert to_traditional_unit("109547-0", 0.172) == pytest.approx(1.0)
|