fpowerkit 0.2.0rc0__tar.gz → 0.2.2__tar.gz

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (28) hide show
  1. fpowerkit-0.2.2/PKG-INFO +50 -0
  2. fpowerkit-0.2.2/README.md +62 -0
  3. {fpowerkit-0.2.0rc0 → fpowerkit-0.2.2}/fpowerkit/__init__.py +2 -0
  4. {fpowerkit-0.2.0rc0 → fpowerkit-0.2.2}/fpowerkit/grid.py +3 -3
  5. {fpowerkit-0.2.0rc0 → fpowerkit-0.2.2}/fpowerkit/solbase.py +2 -1
  6. fpowerkit-0.2.2/fpowerkit/solcmb.py +46 -0
  7. {fpowerkit-0.2.0rc0 → fpowerkit-0.2.2}/fpowerkit/soldist.py +43 -27
  8. {fpowerkit-0.2.0rc0 → fpowerkit-0.2.2}/fpowerkit/soldss.py +18 -10
  9. fpowerkit-0.2.2/fpowerkit/solgcal.py +132 -0
  10. {fpowerkit-0.2.0rc0 → fpowerkit-0.2.2}/fpowerkit/solnt.py +1 -1
  11. fpowerkit-0.2.2/fpowerkit.egg-info/PKG-INFO +50 -0
  12. {fpowerkit-0.2.0rc0 → fpowerkit-0.2.2}/fpowerkit.egg-info/SOURCES.txt +2 -0
  13. {fpowerkit-0.2.0rc0 → fpowerkit-0.2.2}/fpowerkit.egg-info/requires.txt +0 -2
  14. {fpowerkit-0.2.0rc0 → fpowerkit-0.2.2}/setup.py +2 -2
  15. fpowerkit-0.2.0rc0/PKG-INFO +0 -30
  16. fpowerkit-0.2.0rc0/README.md +0 -44
  17. fpowerkit-0.2.0rc0/fpowerkit.egg-info/PKG-INFO +0 -30
  18. {fpowerkit-0.2.0rc0 → fpowerkit-0.2.2}/LICENSE +0 -0
  19. {fpowerkit-0.2.0rc0 → fpowerkit-0.2.2}/fpowerkit/bus.py +0 -0
  20. {fpowerkit-0.2.0rc0 → fpowerkit-0.2.2}/fpowerkit/cases.py +0 -0
  21. {fpowerkit-0.2.0rc0 → fpowerkit-0.2.2}/fpowerkit/ess.py +0 -0
  22. {fpowerkit-0.2.0rc0 → fpowerkit-0.2.2}/fpowerkit/gen.py +0 -0
  23. {fpowerkit-0.2.0rc0 → fpowerkit-0.2.2}/fpowerkit/line.py +0 -0
  24. {fpowerkit-0.2.0rc0 → fpowerkit-0.2.2}/fpowerkit/pvwind.py +0 -0
  25. {fpowerkit-0.2.0rc0 → fpowerkit-0.2.2}/fpowerkit/utils.py +0 -0
  26. {fpowerkit-0.2.0rc0 → fpowerkit-0.2.2}/fpowerkit.egg-info/dependency_links.txt +0 -0
  27. {fpowerkit-0.2.0rc0 → fpowerkit-0.2.2}/fpowerkit.egg-info/top_level.txt +0 -0
  28. {fpowerkit-0.2.0rc0 → fpowerkit-0.2.2}/setup.cfg +0 -0
@@ -0,0 +1,50 @@
1
+ Metadata-Version: 2.2
2
+ Name: fpowerkit
3
+ Version: 0.2.2
4
+ Summary: A Distflow PDN solver based on Gurobi.
5
+ Author: fmy_xfk
6
+ Classifier: Programming Language :: Python :: 3
7
+ Classifier: License :: OSI Approved :: MIT License
8
+ Classifier: Operating System :: OS Independent
9
+ Requires-Python: >=3.8
10
+ Description-Content-Type: text/markdown
11
+ License-File: LICENSE
12
+ Requires-Dist: feasytools>=0.0.21
13
+ Requires-Dist: numpy>=1.20.0
14
+ Dynamic: author
15
+ Dynamic: classifier
16
+ Dynamic: description
17
+ Dynamic: description-content-type
18
+ Dynamic: requires-dist
19
+ Dynamic: requires-python
20
+ Dynamic: summary
21
+
22
+ # FPowerKit - A power distribution network calculation component
23
+
24
+ This is a package designed for power distribution network solving.
25
+
26
+ This package is affiliated to V2Sim, an open-aource microscopic V2G simulation platform in urban power and transportation network. If you are using the modified DistFlow model in this package, please cite the [paper](https://ieeexplore.ieee.org/document/10970754):
27
+
28
+ ```
29
+ @ARTICLE{10970754,
30
+ author={Qian, Tao and Fang, Mingyu and Hu, Qinran and Shao, Chengcheng and Zheng, Junyi},
31
+ journal={IEEE Transactions on Smart Grid},
32
+ title={V2Sim: An Open-Source Microscopic V2G Simulation Platform in Urban Power and Transportation Network},
33
+ year={2025},
34
+ pages={1-1},
35
+ keywords={Vehicle-to-grid;Partial discharges;Microscopy;Batteries;Planning;Discharges (electric);Optimization;Vehicle dynamics;Transportation;Roads;EV charging load simulation;microscopic EV behavior;Vehicle-to-grid;charging station fault sensing},
36
+ doi={10.1109/TSG.2025.3560976}}
37
+
38
+ ```
39
+
40
+ There are 3 modes for this package to work:
41
+
42
+ - Optimal power flow (OPF): Use cvxpy to solve the optimal power flow and determine the output of the generators.
43
+
44
+ - Power flow calculation: Use OpenDSS/GridCal/Inner Newton-Raphson method to solve the power flow.
45
+
46
+ - Hybrid: Use OPF to determine the initial value, and then use OpenDSS/GridCal/Inner Newton-Raphson to perform accurate calculation.
47
+
48
+ Since this package is still under development, the API is unstable and may be changed anytime.
49
+
50
+ Please visit https://gitee.com/fmy_xfk/fpowerkit to read the detailed introduction and the usage.
@@ -0,0 +1,62 @@
1
+ # FPowerKit 配电网运算组件
2
+ **本仓库已上线PyPI**,您可以通过`pip install fpowerkit`直接以Python包的形式安装使用本仓库的代码!
3
+
4
+ 这个项目是[V2Sim](https://gitee.com/fmy_xfk/v2sim)的附属项目。V2Sim的论文请见如下链接
5
+
6
+ - 正式版:https://ieeexplore.ieee.org/document/10970754
7
+
8
+ - 早期版本:https://arxiv.org/abs/2412.09808
9
+
10
+ 如果你正在使用本项目中的**改进配电网DistFlow模型**,请引用[V2Sim正式版论文](https://ieeexplore.ieee.org/document/10970754):
11
+
12
+ ```
13
+ @ARTICLE{10970754,
14
+ author={Qian, Tao and Fang, Mingyu and Hu, Qinran and Shao, Chengcheng and Zheng, Junyi},
15
+ journal={IEEE Transactions on Smart Grid},
16
+ title={V2Sim: An Open-Source Microscopic V2G Simulation Platform in Urban Power and Transportation Network},
17
+ year={2025},
18
+ pages={1-1},
19
+ keywords={Vehicle-to-grid;Partial discharges;Microscopy;Batteries;Planning;Discharges (electric);Optimization;Vehicle dynamics;Transportation;Roads;EV charging load simulation;microscopic EV behavior;Vehicle-to-grid;charging station fault sensing},
20
+ doi={10.1109/TSG.2025.3560976}}
21
+
22
+ ```
23
+
24
+ IEEE33和IEEE69节点的配网数据从公开渠道收集。除配网数据以外,本仓库代码均遵循LGPL3.0协议使用。
25
+
26
+ ## 简介
27
+ - 依赖于feasytools和numpy: `pip install feasytools numpy`(请自行安装Gurobi并申请许可证)
28
+ - 包含电网的描述(含母线、发电机、线路、光伏、风机和储能等)和改进配电网DistFlow模型求解。
29
+ - 优化目标为“发电成本最小”。发电成本模型为二次函数$f(x)=ax^2+bx+c$或者一次函数$f(x)=bx+c$。
30
+ - 内含IEEE 33节点配电网和IEEE 69节点配电网,可通过以下方式快速创建:
31
+ ```py
32
+ from fpowerkit import PDNCases
33
+ grid_obj33 = PDNCases.IEEE33()
34
+ grid_obj69 = PDNCases.IEEE69()
35
+ ```
36
+
37
+ ## 使用
38
+
39
+ 克隆本仓库,并输入以下命令开始求解:
40
+
41
+ ```bash
42
+ python main.py -g cases/33base.xml
43
+ ```
44
+
45
+ 请注意上述命令不适用于pip安装的版本。
46
+
47
+ `33base`描述了IEEE 33节点配电网模型。换成`3nodes`则是一个极简版3节点辐射形配电网模型,结构如下:
48
+
49
+ ```
50
+ G0 G1
51
+ | |
52
+ B0->B1->B2
53
+ | |
54
+ L1 L2
55
+ ```
56
+
57
+ 您也换成自己的配电网文件来求解,例如`python main.py -g path/to/your_case.xml`
58
+
59
+ ## 配电网文件格式
60
+ [XML格式](docs/xml_file.md)
61
+
62
+ ZIP格式已经不再支持。
@@ -3,4 +3,6 @@ from .solbase import *
3
3
  from .solnt import *
4
4
  from .soldist import *
5
5
  from .soldss import *
6
+ from .solcmb import *
7
+ from .solgcal import *
6
8
  from .cases import PDNCases
@@ -91,13 +91,13 @@ class Grid:
91
91
  self._ladjfb[line.fBus].append(line)
92
92
  self._ladjtb[line.tBus].append(line)
93
93
  for gen in self._gens.values():
94
- assert gen.BusID in self._bnames
94
+ assert gen.BusID in self._bnames, f"Bus {gen.BusID} undefined"
95
95
  self._gatb[gen.BusID].append(gen)
96
96
  for pvw in self._pvws.values():
97
- assert pvw.BusID in self._bnames
97
+ assert pvw.BusID in self._bnames, f"Bus {pvw.BusID} undefined"
98
98
  self._patb[pvw.BusID].append(pvw)
99
99
  for ess in self._esss.values():
100
- assert ess.BusID in self._bnames
100
+ assert ess.BusID in self._bnames, f"Bus {ess.BusID} undefined"
101
101
  self._eatb[ess.BusID].append(ess)
102
102
 
103
103
  @property
@@ -15,9 +15,10 @@ class GridSolveResult(IntEnum):
15
15
 
16
16
 
17
17
  class SolverBase(ABC):
18
- def __init__(self, grid:Grid, eps:float = 1e-6, default_saveto:str = DEFAULT_SAVETO, **kwargs):
18
+ def __init__(self, grid:Grid, eps:float = 1e-6, max_iter:int = 1000, *, default_saveto:str = DEFAULT_SAVETO, **kwargs):
19
19
  self.grid = grid
20
20
  self.eps = eps
21
+ self.max_iter = max_iter
21
22
  self.saveto = default_saveto
22
23
 
23
24
  def SetErrorSaveTo(self, path:str = DEFAULT_SAVETO):
@@ -0,0 +1,46 @@
1
+ from .grid import Grid
2
+ from .solbase import DEFAULT_SAVETO, GridSolveResult, SolverBase
3
+ from warnings import warn
4
+
5
+ ESTIMATORS = ['distflow']
6
+ CALCULATORS = ['opendss', 'newton', 'gridcal', 'none']
7
+ CALCULATORS_NEED_SOURCE_BUS = ['opendss', 'gridcal']
8
+
9
+ class CombinedSolver(SolverBase):
10
+ """
11
+ A class that use DistFlowSolver to estimate the power flow and then use OpenDSSSolver or NewtonSolver to solve the power flow problem.
12
+ """
13
+ def __init__(self, grid:Grid, eps:float = 1e-6, max_iter:int = 1000, *,
14
+ default_saveto:str = DEFAULT_SAVETO, estimator:str = 'distflow',
15
+ calculator:str = 'newton', mlrp:float = 0.5 ,source_bus:str = ""):
16
+ super().__init__(grid, eps, max_iter, default_saveto = default_saveto)
17
+ assert estimator in ESTIMATORS, f"Invalid estimator '{estimator}'. Choose from: " + ','.join(ESTIMATORS) + "."
18
+ assert calculator in CALCULATORS, f"Invalid solver type '{calculator}'. Choose from: " + ','.join(CALCULATORS) + "."
19
+
20
+ from .soldist import DistFlowSolver
21
+ self.est = DistFlowSolver(grid, mlrp = mlrp)
22
+ self.cal_str = calculator
23
+ if calculator in CALCULATORS_NEED_SOURCE_BUS:
24
+ assert source_bus != "", "source_bus cannot be empty when using OpenDSSSolver."
25
+ self.source_bus = source_bus
26
+ else:
27
+ if source_bus != "":
28
+ warn(Warning("source_bus is ignored when not using OpenDSSSolver."))
29
+
30
+ def solve(self, _t:int, /, *, timeout_s: float = 1):
31
+ res, obj = self.est.solve(_t, timeout_s=timeout_s)
32
+ if res == GridSolveResult.Failed:
33
+ return res, obj
34
+ if self.cal_str == 'none':
35
+ return res, obj
36
+ elif self.cal_str == 'opendss':
37
+ from .soldss import OpenDSSSolver
38
+ solver = OpenDSSSolver(self.est.grid, source_bus = self.source_bus)
39
+ elif self.cal_str == 'gridcal':
40
+ from .solgcal import GridCalSolver
41
+ solver = GridCalSolver(self.est.grid, slack_bus = self.source_bus)
42
+ else:
43
+ from .solnt import NewtonSolver
44
+ solver = NewtonSolver(self.est.grid)
45
+ res, obj = solver.solve(_t, timeout_s = timeout_s)
46
+ return res, obj
@@ -1,5 +1,4 @@
1
1
  from itertools import chain
2
- import cvxpy as cp
3
2
  from pathlib import Path
4
3
  from typing import Optional, Union
5
4
  from dataclasses import dataclass
@@ -7,8 +6,7 @@ from collections import deque
7
6
  import math
8
7
  from .solbase import *
9
8
 
10
- Var = cp.Variable
11
- VF = Union[Var, float]
9
+ VF = Union['Var', float] # type: ignore
12
10
 
13
11
  @dataclass
14
12
  class LoadReduceModule:
@@ -67,8 +65,8 @@ class IslandResult(IntEnum):
67
65
 
68
66
  class DistFlowSolver(SolverBase):
69
67
  '''DistFlow solver'''
70
- def __init__(self, grid: Grid, eps: float = 1e-6, default_saveto: str = DEFAULT_SAVETO, /,
71
- *, mlrp: float = 0.5, secondary_cost: bool = True):
68
+ def __init__(self, grid:Grid, eps:float = 1e-6, max_iter:int = 1000, *,
69
+ default_saveto:str = DEFAULT_SAVETO, mlrp: float = 0.5, secondary_cost: bool = True):
72
70
  '''
73
71
  Initialize
74
72
  grid: Grid object
@@ -79,7 +77,7 @@ class DistFlowSolver(SolverBase):
79
77
  If True, the cost is calculated as CostA * Pg^2 + CostB * Pg + CostC,
80
78
  which is likely to induce numerical instability.
81
79
  '''
82
- super().__init__(grid, eps, default_saveto)
80
+ super().__init__(grid, eps, max_iter, default_saveto = default_saveto)
83
81
  self._decb: dict[BusID, LoadReduceModule] = {}
84
82
  self.C = 1e9
85
83
  self._mlrp = mlrp
@@ -192,6 +190,15 @@ class DistFlowSolver(SolverBase):
192
190
  else:
193
191
  return GridSolveResult.PartialOK, val
194
192
 
193
+ def __chkv(self, d: Union[None, np.ndarray]) -> float:
194
+ assert d is not None, "Value is None"
195
+ assert isinstance(d, (np.ndarray, np.floating, float)), f"Value is {type(d)}"
196
+ ret = d.item()
197
+ assert isinstance(ret, float), f"Value is not a float: {type(ret)}"
198
+ assert ret != float('inf'), "Value is inf"
199
+ assert ret != float('-inf'), "Value is -inf"
200
+ return ret
201
+
195
202
  def __solve(self, _t: int, island: _Island, timeout_s: float, relaxV: bool, relaxI: bool, clear_results: bool = False) -> 'tuple[IslandResult, float]':
196
203
 
197
204
  ''' ---------Variables----------
@@ -205,10 +212,15 @@ class DistFlowSolver(SolverBase):
205
212
  P[i,j]: Line active power
206
213
  Q[i,j]: Line reactive power
207
214
  '''
215
+ try:
216
+ import cvxpy as cp
217
+ from cvxpy import Variable as Var
218
+ except ImportError:
219
+ raise ImportError("cvxpy or ecos is not installed. Please install them using 'pip install cvxpy ecos'")
208
220
  cons:list[cp.Constraint] = []
209
221
  # Create GEN vars
210
- pg0: dict[str, VF] = {}
211
- qg0: dict[str, VF] = {}
222
+ pg0: 'dict[str, VF]' = {}
223
+ qg0: 'dict[str, VF]' = {}
212
224
  for gID, g in island.GenItems():
213
225
  if g.FixedP:
214
226
  assert g.P is not None
@@ -246,10 +258,10 @@ class DistFlowSolver(SolverBase):
246
258
  cons.append(pvwp[pID] * math.sqrt(1 - p.PF**2) == pvwq[pID])
247
259
 
248
260
  # Bind GEN vars to Bus
249
- pg: dict[str, list[VF]] = {b: [] for b in island.Buses}
250
- qg: dict[str, list[VF]] = {b: [] for b in island.Buses}
251
- pd: dict[str, float] = {bID: b.Pd(_t) for bID, b in island.BusItems()}
252
- qd: dict[str, float] = {bID: b.Qd(_t) for bID, b in island.BusItems()}
261
+ pg: 'dict[str, list[VF]]' = {b: [] for b in island.Buses}
262
+ qg: 'dict[str, list[VF]]' = {b: [] for b in island.Buses}
263
+ pd: 'dict[str, float]' = {bID: b.Pd(_t) for bID, b in island.BusItems()}
264
+ qd: 'dict[str, float]' = {bID: b.Qd(_t) for bID, b in island.BusItems()}
253
265
  for gID, g in island.GenItems():
254
266
  pg[g.BusID].append(pg0[gID])
255
267
  qg[g.BusID].append(qg0[gID])
@@ -288,6 +300,8 @@ class DistFlowSolver(SolverBase):
288
300
  l = {lID: Var(name=f"l_{lID}", nonneg=True) for lID in island.Lines}
289
301
 
290
302
  for lID, ln in island.LineItems():
303
+ if ln.max_I == math.inf:
304
+ continue
291
305
  if relaxI:
292
306
  dlmax[lID] = Var(name=f"dlmax_{lID}", nonneg=True)
293
307
  cons.append(l[lID] <= (ln.max_I/island.grid.Ib) ** 2 + dlmax[lID])
@@ -314,14 +328,14 @@ class DistFlowSolver(SolverBase):
314
328
  inflow = cp.sum([P[ln.ID] - ln.R * l[ln.ID] for ln in flow_in if ln.ID in island.Lines])
315
329
  outflow = cp.sum([P[ln.ID] for ln in flow_out if ln.ID in island.Lines])
316
330
  cons.append(
317
- inflow + cp.sum(pg[j]) == outflow + pd[j] - dec
331
+ inflow + cp.sum(pg[j]) == outflow + pd[j] - dec # type: ignore
318
332
  )
319
333
 
320
334
  # Q constraint
321
335
  q_inflow = cp.sum([Q[ln.ID] - ln.X * l[ln.ID] for ln in flow_in if ln.ID in island.Lines])
322
336
  q_outflow = cp.sum([Q[ln.ID] for ln in flow_out if ln.ID in island.Lines])
323
337
  cons.append(
324
- q_inflow + cp.sum(qg[j]) == q_outflow + qd[j]
338
+ q_inflow + cp.sum(qg[j]) == q_outflow + qd[j] # type: ignore
325
339
  )
326
340
 
327
341
  for lid, line in island.LineItems():
@@ -355,7 +369,7 @@ class DistFlowSolver(SolverBase):
355
369
  problem = cp.Problem(cp.Minimize(decs + goal + crpe), cons)
356
370
 
357
371
  try:
358
- problem.solve(solver=cp.ECOS, verbose=False)
372
+ problem.solve(solver=cp.ECOS, verbose=False, max_iters=self.max_iter)
359
373
  except cp.SolverError as e:
360
374
  if "installed" in e.args[0]:
361
375
  raise e
@@ -377,22 +391,22 @@ class DistFlowSolver(SolverBase):
377
391
  return IslandResult.Failed, -1
378
392
 
379
393
  for j, bus in island.BusItems():
380
- bus._v = v[j].value.item() ** 0.5
394
+ bus._v = self.__chkv(v[j].value) ** 0.5
381
395
 
382
396
  for lid, line in island.LineItems():
383
- line.I = l[lid].value.item() ** 0.5
384
- line.P = P[lid].value.item()
385
- line.Q = Q[lid].value.item()
397
+ line.I = self.__chkv(l[lid].value) ** 0.5
398
+ line.P = self.__chkv(P[lid].value)
399
+ line.Q = self.__chkv(Q[lid].value)
386
400
 
387
401
  for j, gen in island.GenItems():
388
402
  p = pg0[j]
389
- if isinstance(p, Var) and p.value is not None: gen._p = p.value.item()
403
+ if isinstance(p, Var) and p.value is not None: gen._p = self.__chkv(p.value)
390
404
  q = qg0[j]
391
- if isinstance(q, Var): gen._q = q.value.item()
405
+ if isinstance(q, Var): gen._q = self.__chkv(q.value)
392
406
 
393
407
  for pID, p in island.PVWItems():
394
- p._pr = pvwp[pID].value.item()
395
- p._qr = pvwq[pID].value.item()
408
+ p._pr = self.__chkv(pvwp[pID].value)
409
+ p._qr = self.__chkv(pvwq[pID].value)
396
410
  pgen = p.P(_t)
397
411
  p._cr = 1 - p._pr / pgen if pgen > 0 else 0
398
412
 
@@ -400,19 +414,21 @@ class DistFlowSolver(SolverBase):
400
414
  self._ofbuses.clear()
401
415
  if relaxV:
402
416
  for bID, bv in chain(dvmax.items(), dvmin.items()):
403
- if bv.value > 1e-8:
417
+ if self.__chkv(bv.value) > 1e-8:
404
418
  overflow = True
405
419
  self._ofbuses.add(bID)
406
420
 
407
421
  self._oflines.clear()
408
422
  if relaxI:
409
423
  for lID, lv in dlmax.items():
410
- if lv.value > 1e-8:
424
+ if self.__chkv(lv.value) > 1e-8:
411
425
  overflow = True
412
426
  self._oflines.add(lID)
413
427
 
414
428
  for bus, lim in self._decb.items():
415
- lim.Reduction = Pdec[bus].value.item()
429
+ lim.Reduction = self.__chkv(Pdec[bus].value)
416
430
  if lim.Reduction < 1e-8: lim.Reduction = 0
417
431
 
418
- return IslandResult.OverFlow if overflow else IslandResult.OK, goal.value
432
+ if not isinstance(goal, (int, float)):
433
+ goal = self.__chkv(goal.value)
434
+ return IslandResult.OverFlow if overflow else IslandResult.OK, goal
@@ -1,9 +1,13 @@
1
1
  from .solbase import *
2
2
 
3
3
  class OpenDSSSolver(SolverBase):
4
- def __init__(self, grid:Grid, source_bus:str, eps:float = 1e-6, default_saveto:str = DEFAULT_SAVETO, max_iter:int = 100, init_t:int = 0):
5
- super().__init__(grid, eps, default_saveto)
6
- from py_dss_interface import DSS
4
+ def __init__(self, grid:Grid, eps:float = 1e-6, max_iter:int = 1000, *,
5
+ default_saveto:str = DEFAULT_SAVETO, source_bus:str, init_t:int = 0):
6
+ super().__init__(grid, eps, max_iter, default_saveto = default_saveto)
7
+ try:
8
+ from py_dss_interface import DSS
9
+ except ImportError:
10
+ raise ImportError("py_dss_interface or OpenDSS is not installed. Please install OpenDSS first and then py_dss_interface using 'pip install py_dss_interface'")
7
11
  self._g = grid
8
12
  t = init_t
9
13
  d = DSS()
@@ -16,9 +20,9 @@ class OpenDSSSolver(SolverBase):
16
20
  bid = bus.ID
17
21
  if bid != bid.lower():
18
22
  raise ValueError(f"Bus ID {bid} must be lower case")
19
- p = bus.Pd(t) * grid.Sb_kVA
20
- q = bus.Qd(t) * grid.Sb_kVA
21
- d.text(f"New Load.{bid} bus1={bid} kv={self.grid.Ub} kW={p} kvar={q} vmin={bus.MinV} vmax={bus.MaxV}")
23
+ p = bus.Pd(t)
24
+ q = bus.Qd(t)
25
+ d.text(f"New Load.{bid} bus1={bid} kv={self.grid.Ub} kW={p*grid.Sb_kVA} kvar={q*grid.Sb_kVA} vmin={bus.MinV} vmax={bus.MaxV}")
22
26
  for line in self.grid.Lines:
23
27
  fid = line.fBus
24
28
  tid = line.tBus
@@ -57,15 +61,19 @@ class OpenDSSSolver(SolverBase):
57
61
  for gen in self.grid.Gens:
58
62
  if gen.ID != gen.ID.lower():
59
63
  raise ValueError(f"Generator ID {gen.ID} must be lower case")
60
- if gen.P is None:
64
+ bid = gen.BusID
65
+ if gen.P is None and bid != self.source_bus:
61
66
  raise ValueError(f"Generator {gen.ID} has no P value")
62
67
  p = gen.P(t) if isinstance(gen.P, TimeFunc) else gen.P
63
- if gen.Q is None:
68
+ if gen.Q is None and bid != self.source_bus:
64
69
  raise ValueError(f"Generator {gen.ID} has no Q value")
65
70
  q = gen.Q(t) if isinstance(gen.Q, TimeFunc) else gen.Q
66
- bid = gen.BusID
67
71
 
68
- s = f"New Generator.{gen.ID} bus1={bid} kv={grid.Ub} kw={p*grid.Sb_kVA} kvar={q*grid.Sb_kVA}"
72
+ s = f"New Generator.{gen.ID} bus1={bid} kv={grid.Ub} "
73
+ if p is not None:
74
+ s+=f"kw={p*grid.Sb_kVA} "
75
+ if q is not None:
76
+ s+=f"kvar={q*grid.Sb_kVA}"
69
77
  d.text(s)
70
78
  d.text("set mode=snapshot")
71
79
  self.dss = d
@@ -0,0 +1,132 @@
1
+ from warnings import warn
2
+ from .solbase import *
3
+
4
+ class GridCalSolver(SolverBase):
5
+ def __init__(self, grid:Grid, eps:float = 1e-6, max_iter:int = 1000, *, default_saveto:str = DEFAULT_SAVETO,
6
+ slack_bus:str, slack_gen:str = "", init_t:int = 0):
7
+ try:
8
+ import GridCalEngine as gce
9
+ except ImportError:
10
+ raise ImportError("GridCalEngine is not installed. Please install it using 'pip install GridCalEngine'")
11
+ super().__init__(grid, eps, max_iter, default_saveto = default_saveto)
12
+ self.max_iter = max_iter
13
+ self._g = grid
14
+ assert slack_bus in grid.BusNames
15
+ self.slack_bus = slack_bus
16
+ if slack_gen == "":
17
+ slack_gens = grid.GensAtBus(slack_bus)
18
+ if len(slack_gens) == 0:
19
+ raise RuntimeError("Slack generator not identified, and no generator connects with the slack bus.")
20
+ slack_gen = slack_gens[0].ID
21
+ #print(f"FPowerKit Info: Use {slack_gen} as the slack generator.")
22
+ assert slack_gen in grid.GenNames
23
+ self.slack_gen = slack_gen
24
+ gcg = gce.MultiCircuit(Sbase=grid.Sb_MVA)
25
+ t = init_t
26
+ buses:dict[str, gce.Bus] = {}
27
+ for bus in grid.Buses:
28
+ bid = bus.ID
29
+ p = bus.Pd(t)
30
+ q = bus.Qd(t)
31
+ b_inst = gce.Bus(bid,
32
+ Vnom=grid.Ub, # type:ignore
33
+ vmin=bus.MinV, vmax=bus.MaxV, is_slack=bid==slack_bus)
34
+ buses[bid] = b_inst
35
+ gcg.add_bus(b_inst)
36
+ gcg.add_load(b_inst, gce.Load(bid+"_load", P = p*grid.Sb_MVA, Q = q*grid.Sb_MVA))
37
+
38
+ for line in self.grid.Lines:
39
+ fid = line.fBus
40
+ tid = line.tBus
41
+ gcg.add_line(gce.Line(buses[fid], buses[tid], name=line.ID, r=line.R, x=line.X))
42
+
43
+ for pvw in self.grid.PVWinds:
44
+ if pvw.Pr is None:
45
+ raise ValueError(f"PVWind {pvw.ID} has no Pr value")
46
+ p = pvw.Pr
47
+ if pvw.Qr is None:
48
+ raise ValueError(f"PVWind {pvw.ID} has no Qr value")
49
+ q = pvw.Qr
50
+ bid = pvw.BusID
51
+ g_inst = gce.Generator(pvw.ID, P=p*grid.Sb_MVA, power_factor=pvw.PF, Sbase = grid.Sb_MVA)
52
+ gcg.add_generator(buses[bid], g_inst)
53
+
54
+ for ess in self.grid.ESSs:
55
+ if ess.ID != ess.ID.lower():
56
+ raise ValueError(f"ESS ID {ess.ID} must be lower case")
57
+ if ess.P is None:
58
+ raise ValueError(f"ESS {ess.ID} has no P value")
59
+ p = ess.P
60
+ if ess.Q is None:
61
+ raise ValueError(f"ESS {ess.ID} has no Q value")
62
+ q = ess.Q
63
+ bid = ess.BusID
64
+ if p > 0: # charging = load
65
+ bus = self.grid.Bus(bid)
66
+ gcg.add_load(buses[bid], gce.Load(ess.ID, P=p*grid.Sb_MVA, Q=q*grid.Sb_MVA))
67
+ else: # discharging = generator
68
+ g_inst = gce.Generator(ess.ID, P=p*grid.Sb_MVA, power_factor=ess.PF, Sbase = grid.Sb_MVA)
69
+ gcg.add_generator(buses[bid], g_inst)
70
+
71
+ for gen in self.grid.Gens:
72
+ bid = gen.BusID
73
+ if gen.ID == slack_gen:
74
+ g_inst = gce.Generator(gen.ID, vset=1.0)
75
+ if gen.P is not None or gen.Q is not None:
76
+ warn(f"Given value of P and Q of the slack generator {gen.ID} is ignored.")
77
+ else:
78
+ if gen.P is None:
79
+ p = 0
80
+ else:
81
+ p = gen.P(t) if isinstance(gen.P, TimeFunc) else gen.P
82
+ if gen.Q is None:
83
+ pf = 0.8
84
+ else:
85
+ q = gen.Q(t) if isinstance(gen.Q, TimeFunc) else gen.Q
86
+ pf = p / (p**2 + q**2) ** 0.5
87
+ g_inst = gce.Generator(gen.ID, P=p*grid.Sb_MVA, power_factor=pf, Sbase = grid.Sb_MVA, vset=1.0)
88
+ gcg.add_generator(buses[bid], g_inst)
89
+
90
+ self.grid_cal = gcg
91
+
92
+ def solve(self, _t:int, /, *, timeout_s:float = 1) -> 'tuple[GridSolveResult, float]':
93
+ import GridCalEngine as gce
94
+ options = gce.PowerFlowOptions(gce.SolverType.NR,
95
+ max_iter=self.max_iter,
96
+ retry_with_other_methods=False,
97
+ tolerance=self.eps,
98
+ control_q=False,
99
+ control_taps_phase=False,
100
+ control_taps_modules=False,
101
+ apply_temperature_correction=False,
102
+ use_stored_guess=False,
103
+ initialize_angles=True,
104
+ verbose=False)
105
+
106
+ power_flow = gce.PowerFlowDriver(self.grid_cal, options)
107
+ power_flow.run()
108
+ assert isinstance(power_flow.results, gce.PowerFlowResults)
109
+ if not power_flow.results.converged:
110
+ return GridSolveResult.Failed, 0.0
111
+ bus_res = power_flow.results.get_bus_df()
112
+
113
+ for i, bn in enumerate(self._g.BusNames):
114
+ b = self.grid.Bus(bn)
115
+ v = bus_res.loc[bn, 'Vm']
116
+ assert isinstance(v, (float, np.floating)), f"Bus {bn} voltage is not a float: {type(v)}"
117
+ b._v = float(v)
118
+ angle = bus_res.loc[bn, 'Va']
119
+ assert isinstance(angle, (float, np.floating)), f"Bus {bn} angle is not a float: {type(angle)}"
120
+ b.theta = float(angle) / 180 * math.pi
121
+
122
+ for l in self.grid.Lines:
123
+ vi = self.grid.Bus(l.fBus).V_cpx
124
+ vj = self.grid.Bus(l.tBus).V_cpx
125
+ assert vi is not None and vj is not None
126
+ i = (vi-vj)/l.Z
127
+ l.I = abs(i)
128
+ s = vi*i.conjugate()
129
+ l.P = s.real
130
+ l.Q = s.imag
131
+
132
+ return GridSolveResult.OK, 0.0
@@ -9,7 +9,7 @@ class BusType(IntEnum):
9
9
 
10
10
  class NewtonSolver(SolverBase):
11
11
  def __init__(self, grid:Grid, eps:float = 1e-6, default_saveto:str = DEFAULT_SAVETO, max_iter:int = 100):
12
- super().__init__(grid, eps, default_saveto)
12
+ super().__init__(grid, eps, max_iter, default_saveto = default_saveto)
13
13
  self.Y = grid.YMat()
14
14
  self.G, self.B = self.Y.real, self.Y.imag
15
15
  self.max_iter = max_iter
@@ -0,0 +1,50 @@
1
+ Metadata-Version: 2.2
2
+ Name: fpowerkit
3
+ Version: 0.2.2
4
+ Summary: A Distflow PDN solver based on Gurobi.
5
+ Author: fmy_xfk
6
+ Classifier: Programming Language :: Python :: 3
7
+ Classifier: License :: OSI Approved :: MIT License
8
+ Classifier: Operating System :: OS Independent
9
+ Requires-Python: >=3.8
10
+ Description-Content-Type: text/markdown
11
+ License-File: LICENSE
12
+ Requires-Dist: feasytools>=0.0.21
13
+ Requires-Dist: numpy>=1.20.0
14
+ Dynamic: author
15
+ Dynamic: classifier
16
+ Dynamic: description
17
+ Dynamic: description-content-type
18
+ Dynamic: requires-dist
19
+ Dynamic: requires-python
20
+ Dynamic: summary
21
+
22
+ # FPowerKit - A power distribution network calculation component
23
+
24
+ This is a package designed for power distribution network solving.
25
+
26
+ This package is affiliated to V2Sim, an open-aource microscopic V2G simulation platform in urban power and transportation network. If you are using the modified DistFlow model in this package, please cite the [paper](https://ieeexplore.ieee.org/document/10970754):
27
+
28
+ ```
29
+ @ARTICLE{10970754,
30
+ author={Qian, Tao and Fang, Mingyu and Hu, Qinran and Shao, Chengcheng and Zheng, Junyi},
31
+ journal={IEEE Transactions on Smart Grid},
32
+ title={V2Sim: An Open-Source Microscopic V2G Simulation Platform in Urban Power and Transportation Network},
33
+ year={2025},
34
+ pages={1-1},
35
+ keywords={Vehicle-to-grid;Partial discharges;Microscopy;Batteries;Planning;Discharges (electric);Optimization;Vehicle dynamics;Transportation;Roads;EV charging load simulation;microscopic EV behavior;Vehicle-to-grid;charging station fault sensing},
36
+ doi={10.1109/TSG.2025.3560976}}
37
+
38
+ ```
39
+
40
+ There are 3 modes for this package to work:
41
+
42
+ - Optimal power flow (OPF): Use cvxpy to solve the optimal power flow and determine the output of the generators.
43
+
44
+ - Power flow calculation: Use OpenDSS/GridCal/Inner Newton-Raphson method to solve the power flow.
45
+
46
+ - Hybrid: Use OPF to determine the initial value, and then use OpenDSS/GridCal/Inner Newton-Raphson to perform accurate calculation.
47
+
48
+ Since this package is still under development, the API is unstable and may be changed anytime.
49
+
50
+ Please visit https://gitee.com/fmy_xfk/fpowerkit to read the detailed introduction and the usage.
@@ -10,8 +10,10 @@ fpowerkit/grid.py
10
10
  fpowerkit/line.py
11
11
  fpowerkit/pvwind.py
12
12
  fpowerkit/solbase.py
13
+ fpowerkit/solcmb.py
13
14
  fpowerkit/soldist.py
14
15
  fpowerkit/soldss.py
16
+ fpowerkit/solgcal.py
15
17
  fpowerkit/solnt.py
16
18
  fpowerkit/utils.py
17
19
  fpowerkit.egg-info/PKG-INFO
@@ -1,4 +1,2 @@
1
1
  feasytools>=0.0.21
2
- cvxpy>=1.0
3
2
  numpy>=1.20.0
4
- ecos
@@ -5,7 +5,7 @@ with open("desc.md", "r", encoding="utf8") as f:
5
5
 
6
6
  setup(
7
7
  name="fpowerkit",
8
- version="0.2.0rc0",
8
+ version="0.2.2",
9
9
  author="fmy_xfk",
10
10
  packages=find_packages(),
11
11
  description="A Distflow PDN solver based on Gurobi.",
@@ -17,5 +17,5 @@ setup(
17
17
  "Operating System :: OS Independent",
18
18
  ],
19
19
  python_requires=">=3.8",
20
- install_requires=["feasytools>=0.0.21", "cvxpy>=1.0", "numpy>=1.20.0", "ecos"],
20
+ install_requires=["feasytools>=0.0.21", "numpy>=1.20.0"],
21
21
  )
@@ -1,30 +0,0 @@
1
- Metadata-Version: 2.2
2
- Name: fpowerkit
3
- Version: 0.2.0rc0
4
- Summary: A Distflow PDN solver based on Gurobi.
5
- Author: fmy_xfk
6
- Classifier: Programming Language :: Python :: 3
7
- Classifier: License :: OSI Approved :: MIT License
8
- Classifier: Operating System :: OS Independent
9
- Requires-Python: >=3.8
10
- Description-Content-Type: text/markdown
11
- License-File: LICENSE
12
- Requires-Dist: feasytools>=0.0.21
13
- Requires-Dist: cvxpy>=1.0
14
- Requires-Dist: numpy>=1.20.0
15
- Requires-Dist: ecos
16
- Dynamic: author
17
- Dynamic: classifier
18
- Dynamic: description
19
- Dynamic: description-content-type
20
- Dynamic: requires-dist
21
- Dynamic: requires-python
22
- Dynamic: summary
23
-
24
- # FPowerKit - A power distribution network calculation component
25
-
26
- This is a package based on Gurobipy implementing optimal power flow (OPF).
27
-
28
- Since this package is still under development, the API is unstable and may be changed anytime.
29
-
30
- Please visit https://gitee.com/fmy_xfk/fpowerkit to read the detailed introduction and the usage.
@@ -1,44 +0,0 @@
1
- # FPowerKit 配电网运算组件
2
- **本仓库已上线PyPI**,您可以通过`pip install fpowerkit`直接以Python包的形式安装使用本仓库的代码!
3
-
4
- 这个项目是[V2Sim](https://gitee.com/fmy_xfk/v2sim)的附属项目。V2Sim的论文请见arXiv: https://arxiv.org/abs/2412.09808
5
-
6
- IEEE33和IEEE69节点的配网数据从公开渠道收集。除配网数据以外,本仓库代码均遵循LGPL3.0协议使用。
7
-
8
- ## 简介
9
- - 依赖于feasytools和gurobipy: `pip install feasytools gurobipy`(请自行安装Gurobi并申请许可证)
10
- - 包含电网的描述(含母线、发电机、线路等)和采用Gurobi的配电网DistFlow模型求解。
11
- - 优化目标为“发电成本最小”。发电成本模型为二次函数$f(x)=ax^2+bx+c$。
12
- - 内含IEEE 33节点配电网和IEEE 69节点配电网,可通过以下方式快速创建:
13
- ```py
14
- from fpowerkit import PDNCases
15
- grid_obj33 = PDNCases.IEEE33()
16
- grid_obj69 = PDNCases.IEEE69()
17
- ```
18
-
19
- ## 使用
20
-
21
- 克隆本仓库,并输入以下命令开始求解:
22
-
23
- ```bash
24
- python main.py -g cases/33base.xml
25
- ```
26
-
27
- 请注意上述命令不适用于pip安装的版本。
28
-
29
- `33base`描述了IEEE 33节点配电网模型。换成`3nodes`则是一个极简版3节点辐射形配电网模型,结构如下:
30
-
31
- ```
32
- G0 G1
33
- | |
34
- B0->B1->B2
35
- | |
36
- L1 L2
37
- ```
38
-
39
- 您也换成自己的配电网文件来求解,例如`python main.py -g path/to/your_zipfile.zip`
40
-
41
- ## 配电网文件格式
42
- [XML格式](docs/xml_file.md)
43
-
44
- ZIP格式已经不再支持。
@@ -1,30 +0,0 @@
1
- Metadata-Version: 2.2
2
- Name: fpowerkit
3
- Version: 0.2.0rc0
4
- Summary: A Distflow PDN solver based on Gurobi.
5
- Author: fmy_xfk
6
- Classifier: Programming Language :: Python :: 3
7
- Classifier: License :: OSI Approved :: MIT License
8
- Classifier: Operating System :: OS Independent
9
- Requires-Python: >=3.8
10
- Description-Content-Type: text/markdown
11
- License-File: LICENSE
12
- Requires-Dist: feasytools>=0.0.21
13
- Requires-Dist: cvxpy>=1.0
14
- Requires-Dist: numpy>=1.20.0
15
- Requires-Dist: ecos
16
- Dynamic: author
17
- Dynamic: classifier
18
- Dynamic: description
19
- Dynamic: description-content-type
20
- Dynamic: requires-dist
21
- Dynamic: requires-python
22
- Dynamic: summary
23
-
24
- # FPowerKit - A power distribution network calculation component
25
-
26
- This is a package based on Gurobipy implementing optimal power flow (OPF).
27
-
28
- Since this package is still under development, the API is unstable and may be changed anytime.
29
-
30
- Please visit https://gitee.com/fmy_xfk/fpowerkit to read the detailed introduction and the usage.
File without changes
File without changes
File without changes
File without changes
File without changes