cjnfuncs 3.0__tar.gz → 3.1__tar.gz

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (30) hide show
  1. {cjnfuncs-3.0/src/cjnfuncs.egg-info → cjnfuncs-3.1}/PKG-INFO +20 -23
  2. {cjnfuncs-3.0 → cjnfuncs-3.1}/README.md +16 -21
  3. {cjnfuncs-3.0 → cjnfuncs-3.1}/SMTP.md +35 -20
  4. {cjnfuncs-3.0 → cjnfuncs-3.1}/configman.md +83 -53
  5. {cjnfuncs-3.0 → cjnfuncs-3.1}/core.md +81 -34
  6. {cjnfuncs-3.0 → cjnfuncs-3.1}/deployfiles.md +45 -10
  7. {cjnfuncs-3.0 → cjnfuncs-3.1}/mungePath.md +36 -25
  8. cjnfuncs-3.1/pyproject.toml +52 -0
  9. {cjnfuncs-3.0 → cjnfuncs-3.1}/resourcelock.md +75 -44
  10. {cjnfuncs-3.0 → cjnfuncs-3.1}/rwt.md +56 -22
  11. {cjnfuncs-3.0 → cjnfuncs-3.1}/src/cjnfuncs/SMTP.py +44 -30
  12. {cjnfuncs-3.0 → cjnfuncs-3.1}/src/cjnfuncs/configman.py +121 -103
  13. {cjnfuncs-3.0 → cjnfuncs-3.1}/src/cjnfuncs/core.py +106 -47
  14. {cjnfuncs-3.0 → cjnfuncs-3.1}/src/cjnfuncs/deployfiles.py +34 -23
  15. {cjnfuncs-3.0 → cjnfuncs-3.1}/src/cjnfuncs/mungePath.py +8 -6
  16. {cjnfuncs-3.0 → cjnfuncs-3.1}/src/cjnfuncs/resourcelock.py +44 -30
  17. {cjnfuncs-3.0 → cjnfuncs-3.1}/src/cjnfuncs/rwt.py +86 -78
  18. {cjnfuncs-3.0 → cjnfuncs-3.1}/src/cjnfuncs/timevalue.py +5 -5
  19. {cjnfuncs-3.0 → cjnfuncs-3.1/src/cjnfuncs.egg-info}/PKG-INFO +20 -23
  20. {cjnfuncs-3.0 → cjnfuncs-3.1}/src/cjnfuncs.egg-info/requires.txt +2 -0
  21. {cjnfuncs-3.0 → cjnfuncs-3.1}/timevalue.md +5 -5
  22. cjnfuncs-3.0/pyproject.toml +0 -39
  23. {cjnfuncs-3.0 → cjnfuncs-3.1}/LICENSE +0 -0
  24. {cjnfuncs-3.0 → cjnfuncs-3.1}/MANIFEST.in +0 -0
  25. {cjnfuncs-3.0 → cjnfuncs-3.1}/setup.cfg +0 -0
  26. {cjnfuncs-3.0 → cjnfuncs-3.1}/src/cjnfuncs/__init__.py +0 -0
  27. {cjnfuncs-3.0 → cjnfuncs-3.1}/src/cjnfuncs.egg-info/SOURCES.txt +0 -0
  28. {cjnfuncs-3.0 → cjnfuncs-3.1}/src/cjnfuncs.egg-info/dependency_links.txt +0 -0
  29. {cjnfuncs-3.0 → cjnfuncs-3.1}/src/cjnfuncs.egg-info/entry_points.txt +0 -0
  30. {cjnfuncs-3.0 → cjnfuncs-3.1}/src/cjnfuncs.egg-info/top_level.txt +0 -0
@@ -1,10 +1,12 @@
1
1
  Metadata-Version: 2.4
2
2
  Name: cjnfuncs
3
- Version: 3.0
3
+ Version: 3.1
4
4
  Summary: A collection of core functions for tool script writing
5
5
  Author-email: Chris Nelson <github@cjnaz.com>
6
6
  License-Expression: MIT
7
7
  Project-URL: repository, https://github.com/cjnaz/cjnfuncs
8
+ Keywords: cjnaz,library,cjnfuncs
9
+ Classifier: Programming Language :: Python :: 3
8
10
  Classifier: Topic :: Software Development :: Libraries :: Python Modules
9
11
  Requires-Python: >=3.9
10
12
  Description-Content-Type: text/markdown
@@ -13,7 +15,7 @@ Requires-Dist: requests
13
15
  Requires-Dist: appdirs>=1.4
14
16
  Requires-Dist: dkimpy
15
17
  Requires-Dist: importlib_resources
16
- Requires-Dist: posix-ipc>=1.1.1
18
+ Requires-Dist: posix-ipc>=1.1.1; sys_platform == "linux"
17
19
  Dynamic: license-file
18
20
 
19
21
  # cjnfuncs - A framework and collection of utility functions for script writing
@@ -34,7 +36,7 @@ module | Description/Purpose
34
36
  [SMTP](SMTP.md) | Send notification and email messages
35
37
 
36
38
  Developed and tested on Python 3.9.21 and supported on all higher Python versions.
37
- Developed on Linux. Not supported on Windows (posix-ipc module dependency).
39
+ Developed on Linux. Supported on Windows, except for the resourcelock module (posix-ipc module dependency).
38
40
 
39
41
  In this documentation, "tool script" refers to a Python project that imports and uses cjnfuncs. Some may be simple scripts, and others may themselves be installed packages.
40
42
 
@@ -56,35 +58,30 @@ Project repo: https://github.com/cjnaz/cjnfuncs
56
58
 
57
59
  <br/>
58
60
 
59
- ## Key changes since the prior major public release (version 2.5)
61
+ ## Key changes since the prior major public release (version 3.0)
60
62
 
61
- `run_with_timeout()` (see module `rwt`)
62
- - If a network share (or an internet resource) is
63
- unavailable or extremely slow then the tool script can hang indefinitely. `run_with_timeout()` can wrap any function call
64
- (any callable - built-in, standard library, installed package, or defined within the tool script) with an enforced timeout
65
- and number of retries on timeout so that your code can make rational decisions when there are access issues.
63
+ - Several issues with Windows support were fixed.
66
64
 
67
- `set / restore_logging_level()` on a stack (see module `core`)
68
- - When you want this, you want this. Its used in configman, for instance, to allow for debug logging within the configman code (valuable for cjnfuncs debug and regression testing). If you are developing a hardware sensor driver for example, you can enable debug logging of calls to your driver code
69
- and restore the level before return.
70
- You can use `set_logging_level()` standalone, or with later `restore_logging_level()` calls.
65
+ - `configman.config_item()` now supports a safe_mode switch, which will speed up Windows usage of loadconfig() at some risk. See the note on `config_item()`.
71
66
 
72
- `periodic_log()` (see module `core`)
73
- - `periodic_log()` solves the difficulty of finding the sweet spot of how much logging to do to avoiding flooding the log. You can say "log this event only once every 10 minutes", for example. So even if the log event gets triggered every 100 ms, no problem.
67
+ - Named child loggers are now implemented on several cjnfuncs modules. By default, logging from cjnfuncs modules is disabled (logging events are usually at the INFO or DEBUG
68
+ level, while the default logging level is set to WARNING). For example, logging from configman may be enabled by `logging.getLogger('cjnfuncs.configman').setLevel(logging.INFO)`,
69
+ or using `core.set_logging.level(logging.INFO, 'cjnfuncs.configman')`.
74
70
 
75
- `get_next_dt()` (see module `timevalue`)
76
- - A lot of what I develop are process monitoring tools. These typically implement a `while True` loop where various operations get triggered periodically on their own schedules. `get_next_dt()` provides a simple and clean way to get the next `datetime` to do an operation (in my usage, as defined in a config file). `get_next_dt()` supports arbitrary times of day and days of week. For example, trigger generating a summary report every Thursday at 9AM:
71
+ - Changed mungePath set_attributes from default True to default False to avoid long processing time on Windows by default.
77
72
 
78
- if now_dt > generate_summary_dt: # I suffix datetimes with '_dt' for readability
79
- gen_summary()
80
- generate_summary_dt = get_next_dt('9:00, 'Thursday')
81
-
82
- `mungePath(..., set_attributes=False)` switch
83
- - On network outages, my apps would slow to a crawl. The root of the issue was in checking if a network file exists, with no timeout mechanism. The pathlib `.exists()`, `.is_dir()`, and `is_file()` methods are all susceptible to indefinate hangs. The set_attributues switch has been added to mungePath, with a default value of False. _Note that this is a change to default behavior._ If set True then `refresh_stats()` is called (or you can call it directly yourself, as needed). `refresh_stats()` and `check_file_exists()` have been rewritten to utilize `run_with_timeout()`, with a default timeout of 1.0 seconds. I then `periodic_log()` the access problem. Ah, so much more stable.
73
+ - deployfiles can now create an empty target directory.
84
74
 
85
75
  <br/>
86
76
 
87
77
  ## Revision history
78
+ - 3.1 251109
79
+ Support for and use of child loggers,
80
+ deployfiles create empty dir,
81
+ Windows fixes,
82
+ config_item() safe_mode switch,
83
+ mungePath set_attributes from default False
84
+ - 3.0.1 251005 - Allow '.' in config section names
88
85
  - 3.0 250705 - Added run_with_timeout, set / restore_logging_level, periodic_logging, get_next_dt. Functional change to mungePath.
89
86
  - 2.5 250206 - Added multi-line and quoted string support to configman
90
87
  - 2.4.1 241118 - resource_lock only init lock_info if not existing
@@ -16,7 +16,7 @@ module | Description/Purpose
16
16
  [SMTP](SMTP.md) | Send notification and email messages
17
17
 
18
18
  Developed and tested on Python 3.9.21 and supported on all higher Python versions.
19
- Developed on Linux. Not supported on Windows (posix-ipc module dependency).
19
+ Developed on Linux. Supported on Windows, except for the resourcelock module (posix-ipc module dependency).
20
20
 
21
21
  In this documentation, "tool script" refers to a Python project that imports and uses cjnfuncs. Some may be simple scripts, and others may themselves be installed packages.
22
22
 
@@ -38,35 +38,30 @@ Project repo: https://github.com/cjnaz/cjnfuncs
38
38
 
39
39
  <br/>
40
40
 
41
- ## Key changes since the prior major public release (version 2.5)
41
+ ## Key changes since the prior major public release (version 3.0)
42
42
 
43
- `run_with_timeout()` (see module `rwt`)
44
- - If a network share (or an internet resource) is
45
- unavailable or extremely slow then the tool script can hang indefinitely. `run_with_timeout()` can wrap any function call
46
- (any callable - built-in, standard library, installed package, or defined within the tool script) with an enforced timeout
47
- and number of retries on timeout so that your code can make rational decisions when there are access issues.
43
+ - Several issues with Windows support were fixed.
48
44
 
49
- `set / restore_logging_level()` on a stack (see module `core`)
50
- - When you want this, you want this. Its used in configman, for instance, to allow for debug logging within the configman code (valuable for cjnfuncs debug and regression testing). If you are developing a hardware sensor driver for example, you can enable debug logging of calls to your driver code
51
- and restore the level before return.
52
- You can use `set_logging_level()` standalone, or with later `restore_logging_level()` calls.
45
+ - `configman.config_item()` now supports a safe_mode switch, which will speed up Windows usage of loadconfig() at some risk. See the note on `config_item()`.
53
46
 
54
- `periodic_log()` (see module `core`)
55
- - `periodic_log()` solves the difficulty of finding the sweet spot of how much logging to do to avoiding flooding the log. You can say "log this event only once every 10 minutes", for example. So even if the log event gets triggered every 100 ms, no problem.
47
+ - Named child loggers are now implemented on several cjnfuncs modules. By default, logging from cjnfuncs modules is disabled (logging events are usually at the INFO or DEBUG
48
+ level, while the default logging level is set to WARNING). For example, logging from configman may be enabled by `logging.getLogger('cjnfuncs.configman').setLevel(logging.INFO)`,
49
+ or using `core.set_logging.level(logging.INFO, 'cjnfuncs.configman')`.
56
50
 
57
- `get_next_dt()` (see module `timevalue`)
58
- - A lot of what I develop are process monitoring tools. These typically implement a `while True` loop where various operations get triggered periodically on their own schedules. `get_next_dt()` provides a simple and clean way to get the next `datetime` to do an operation (in my usage, as defined in a config file). `get_next_dt()` supports arbitrary times of day and days of week. For example, trigger generating a summary report every Thursday at 9AM:
51
+ - Changed mungePath set_attributes from default True to default False to avoid long processing time on Windows by default.
59
52
 
60
- if now_dt > generate_summary_dt: # I suffix datetimes with '_dt' for readability
61
- gen_summary()
62
- generate_summary_dt = get_next_dt('9:00, 'Thursday')
63
-
64
- `mungePath(..., set_attributes=False)` switch
65
- - On network outages, my apps would slow to a crawl. The root of the issue was in checking if a network file exists, with no timeout mechanism. The pathlib `.exists()`, `.is_dir()`, and `is_file()` methods are all susceptible to indefinate hangs. The set_attributues switch has been added to mungePath, with a default value of False. _Note that this is a change to default behavior._ If set True then `refresh_stats()` is called (or you can call it directly yourself, as needed). `refresh_stats()` and `check_file_exists()` have been rewritten to utilize `run_with_timeout()`, with a default timeout of 1.0 seconds. I then `periodic_log()` the access problem. Ah, so much more stable.
53
+ - deployfiles can now create an empty target directory.
66
54
 
67
55
  <br/>
68
56
 
69
57
  ## Revision history
58
+ - 3.1 251109
59
+ Support for and use of child loggers,
60
+ deployfiles create empty dir,
61
+ Windows fixes,
62
+ config_item() safe_mode switch,
63
+ mungePath set_attributes from default False
64
+ - 3.0.1 251005 - Allow '.' in config section names
70
65
  - 3.0 250705 - Added run_with_timeout, set / restore_logging_level, periodic_logging, get_next_dt. Functional change to mungePath.
71
66
  - 2.5 250206 - Added multi-line and quoted string support to configman
72
67
  - 2.4.1 241118 - resource_lock only init lock_info if not existing
@@ -37,7 +37,7 @@ EmailPass mypassword
37
37
  EmailFrom me@myserver.com
38
38
  ```
39
39
 
40
- And running this code:
40
+ And this code:
41
41
  ```
42
42
  #!/usr/bin/env python3
43
43
  # ***** SMTP_ex1.py *****
@@ -47,8 +47,8 @@ from cjnfuncs.configman import config_item
47
47
  from cjnfuncs.deployfiles import deploy_files
48
48
  from cjnfuncs.SMTP import snd_notif, snd_email
49
49
 
50
- tool = set_toolname('SMTP_ex1')
51
-
50
+ set_toolname('SMTP_ex1')
51
+ logging.getLogger('cjnfuncs.deployfiles').setLevel(logging.INFO)
52
52
 
53
53
  deploy_files([
54
54
  { 'source': 'SMTP_ex1.cfg', 'target_dir': 'USER_CONFIG_DIR' },
@@ -65,7 +65,7 @@ try:
65
65
  log=True,
66
66
  smtp_config=myconfig)
67
67
  except SndEmailError as e:
68
- logging.warning(f"snd_notif() failed:\n {e}")
68
+ logging.warning(f"snd_notif() failed:\n {type(e).__name__}: {e}")
69
69
 
70
70
  try:
71
71
  snd_email(subj='My first email send',
@@ -74,14 +74,15 @@ try:
74
74
  log=True,
75
75
  smtp_config=myconfig)
76
76
  except SndEmailError as e:
77
- logging.warning(f"snd_email() failed:\n {e}")
77
+ logging.warning(f"snd_email() failed:\n {type(e).__name__}: {e}")
78
78
  ```
79
79
 
80
80
  And finally, running the code produces this output, and a couple sent messages:
81
81
  ```
82
82
  $ ./SMTP_ex1.py
83
- Deployed SMTP_ex1.cfg to /home/me/.config/SMTP_ex1/SMTP_ex1.cfg
84
- Deployed creds_SMTP to /home/me/.config/SMTP_ex1/creds_SMTP
83
+ deployfiles.deploy_files - INFO: Created /home/me/.config/SMTP_ex1
84
+ deployfiles.deploy_files - INFO: Deployed /home/me/.config/SMTP_ex1/SMTP_ex1.cfg
85
+ deployfiles.deploy_files - INFO: Deployed /home/me/.config/SMTP_ex1/creds_SMTP
85
86
  SMTP.snd_notif - WARNING: Notification sent <My first text message> <This is pretty clean interface!>
86
87
  SMTP.snd_email - WARNING: Email sent <My first email send>
87
88
  ```
@@ -188,6 +189,19 @@ config that contains the [SMTP] section).
188
189
  - Example: Given `'4805551212@vzwpix.com 4805551213 +14805551214, +44123456'`, list_to() returns: `['+14805551212', '+14805551213', '+14805551214', '+44123456']`
189
190
 
190
191
 
192
+ <br>
193
+
194
+ ## Controlling logging from within smtp code
195
+
196
+ Logging within the SMTP module uses the `cjnfuncs.smtp` named/child logger. By default this logger is set to the `logging.WARNING` level,
197
+ meaning that no logging messages are produced from within the SMTP code. For validation and debug purposes, logging from within SMTP code
198
+ can be enabled by setting the logging level for this module's logger from within the tool script code:
199
+
200
+ logging.getLogger('cjnfuncs.smtp').setLevel(logging.DEBUG)
201
+
202
+ # Or alternately, use the core module set_logging_level() function:
203
+ set_logging_level (logging.DEBUG, 'cjnfuncs.smtp')
204
+
191
205
 
192
206
  <a id="links"></a>
193
207
 
@@ -231,20 +245,19 @@ Three attempts are made to send the message.
231
245
 
232
246
  `urls_list` (list, default [])
233
247
  - A list of url strings to be passed to the message sending plugin module, which should pass them to the messaging service.
234
- - This list is discarded by `snd_notif()` if not using a messaging service. If you want to send a message with
235
- urls then included them in the `msg` body text.
248
+ - If not using a messaging service then this list is discarded, in which case include the URLs in the `msg` body.
236
249
 
237
250
  `to` (str, default 'NotifList')
238
251
  - To whom to send the message. `to` may be either an explicit string list of email addresses
239
252
  (whitespace or comma separated) or a config param name (also listing one
240
253
  or more whitespace or comma separated email addresses). If the `to` arg does not
241
- contain an '@' it is assumed to be a config param.
254
+ contain an '@' it is assumed to be a config param name.
242
255
  - Define `NotifList` in the config file to use the default `to` value.
243
256
 
244
257
  `log` (bool, default False)
245
- - If True, logs that the message was sent at the WARNING level. If False, logs
246
- at the DEBUG level. Useful for eliminating separate logging messages in the tool script code.
247
- The `subj` field is part of the log message.
258
+ - If True, logs that the message was sent at the WARNING level (using the root logger). If False, logs
259
+ at the DEBUG level (using the 'cjnfuncs.smtp' logger). Useful for eliminating separate logging messages in the tool script code.
260
+ The `subj` field and `msg` body are included in the log message.
248
261
 
249
262
  `smtp_config` (config_item class instance)
250
263
  - config_item class instance containing the [SMTP] section and related params
@@ -283,7 +296,7 @@ default `to` arg value.
283
296
 
284
297
 
285
298
  ### Behaviors and rules
286
- - `snd_notif()` uses `snd_email()` to send the message. See `snd_email()` for related setup.
299
+ - `snd_notif()` uses `snd_email()` to send the message (if not using a messaging service). See `snd_email()` for related setup.
287
300
 
288
301
  <br/>
289
302
 
@@ -313,20 +326,22 @@ Three attempts are made to send the message (see `EmailNTries`, below).
313
326
  - To whom to send the message. `to` may be either an explicit string list of email addresses
314
327
  (whitespace or comma separated) or a config param name in the [SMTP] section (also listing one
315
328
  or more whitespace or comma separated email addresses). If the `to` arg does not
316
- contain an '@' it is assumed to be a config param.
329
+ contain an '@' it is assumed to be a config param name.
317
330
 
318
331
  `body` (str, default None)
319
332
  - A string message to be sent
320
333
 
321
334
  `filename` (str, default None)
322
- - A str or Path to the file to be sent, relative to the `core.tool.cache_dir`, or an absolute path.
335
+ - A str or Path to the file who's content will be sent as the body of the message
336
+ - The file path is relative to the `core.tool.cache_dir`, or an absolute path
323
337
 
324
338
  `htmlfile` (str, default None)
325
- - A str or Path to the html formatted file to be sent, relative to the `core.tool.cache_dir`, or an absolute path.
339
+ - A str or Path to the file who's HTML-formatted content will be sent as the body of the message
340
+ - The file path is relative to the `core.tool.cache_dir`, or an absolute path
326
341
 
327
342
  `log` (bool, default False)
328
- - If True, logs that the message was sent at the WARNING level. If False, logs
329
- at the DEBUG level. Useful for eliminating separate logging messages in the tool script code.
343
+ - If True, logs that the message was sent at the WARNING level (using the root logger). If False, logs
344
+ at the DEBUG level (using the 'cjnfuncs.smpt' logger). Useful for eliminating separate logging messages in the tool script code.
330
345
  The `subj` field is part of the log message.
331
346
 
332
347
  `smtp_config` (config_item class instance)
@@ -350,7 +365,7 @@ The `subj` field is part of the log message.
350
365
  - Password for `EmailServer` login, if required by the server
351
366
 
352
367
  `DontEmail` (default False)
353
- - If True, messages are not sent. Useful for debug. Also blocks `snd_notif()` messages.
368
+ - If True, messages are not sent. Useful for debug. Also blocks `snd_notif()` messages not sent thru a messaging service.
354
369
 
355
370
  `EmailVerbose` (default False)
356
371
  - If True, detailed transactions with the SMTP server are sent to stdout. Useful for debug.
@@ -254,7 +254,7 @@ bad_float: 52.3.5
254
254
 
255
255
  Notables (See **** NOTE # in the above example config file and code):
256
256
  1. loadconfig() looks for `LogLevel` abd `LogFile` and sets the root logger accordingly. If you want to
257
- change the console or file logging format you may also define `ConsoleLogFormat` or `FileLogFormat`, respectively. Logging setups only apply for the primary/master config (`config_item(secondary_config = False)`). The logging level _within_ loadconfig() is set using the `ldcfg_ll` switch (default WARNING level).
257
+ change the console or file logging format you may also define `ConsoleLogFormat` or `FileLogFormat`, respectively. Logging setups only apply for the primary/master config (`config_item(secondary_config = False)`). The logging level _within_ loadconfig() is controlled by the child logger `cjnfuncs.configman` (default WARNING level, see below).
258
258
  2. loadconfig() accepts most any character in a param name, except the comment character `#`, or the param-value separator characters whitespace, `=`, or `:`.
259
259
  3. loadconfig() attempts to load a value as a type `int`, `bool`, `float`, `list`, `dict`, or `tuple`, if the value has the correct syntax for that type. The fallback is to type `str`. Loading all params as type `str` can be forced: `my_config = config_item('configman_ex2.cfg', force_str=True)`.
260
260
  4. Sections are supported, and are accessed as `my_config.getcfg('NotifList', section='SMTP')`. Only
@@ -348,8 +348,8 @@ core.tool.log_dir_base : /home/me/.config/configman_ex3
348
348
 
349
349
  Notables:
350
350
  1. At the startup of the service script, with `loadconfig(tolerate_missing=False)`, the config file must be accessible or a `ConfigError` will be raised. This should be trapped and gracefully handled.
351
- 2. With `loadconfig(tolerate_missing=True)`, `-1` will be returned if the config file is not currently accessible. You will want to add code to output this warning only once, so as to not flood the log. tolerate_missing=True allows the config file to be placed on a network file system.
352
- 3. loadconfig() will return `1` if the config file timestamp has changed (`0` if not changed). The prior `loadconfig(flush_on_reload=True)` will have purged all cfg data and reloaded it from the file.
351
+ 2. With `loadconfig(tolerate_missing=True)`, `-1` will be returned if the config file is not currently accessible. You will want to add code to output this warning only once, so as to not flood the log. tolerate_missing=True allows the config file to be placed on a network file system. Also see `core.periodic_log()`.
352
+ 3. loadconfig() will return `1` if the config file timestamp has changed (`0` if not changed). If the config file was changed the `loadconfig(flush_on_reload=True)` call will have purged all cfg data and reloaded it from the file.
353
353
  4. If this is a `reloaded` case (versus `first`), then cleanup work may be needed prior to the following resource setups.
354
354
  5. Threads and asyncio should use local copies of cfg data so that they don't crash when the cfg data temporarily disappears during the loadconfig() reload. Also see loadconfig's `prereload_callback` parameter.
355
355
 
@@ -433,6 +433,21 @@ Notables:
433
433
  Mapping Protocol Access | No | Yes
434
434
  Save to file | Yes | Yes
435
435
 
436
+ <br>
437
+
438
+ ## Controlling logging from within configman code
439
+
440
+ Logging within the configman module uses the `cjnfuncs.configman` named/child logger. By default this logger is set to the `logging.WARNING` level,
441
+ meaning that no logging messages are produced from within the configman code. For validation and debug purposes, logging from within configman code
442
+ can be enabled by setting the logging level for this module's logger from within the tool script code:
443
+
444
+ logging.getLogger('cjnfuncs.configman').setLevel(logging.DEBUG) # or logging.INFO
445
+
446
+ # Or alternately, use the core module set_logging_level() function:
447
+ set_logging_level (logging.DEBUG, 'cjnfuncs.configman')
448
+
449
+
450
+
436
451
 
437
452
  <a id="links"></a>
438
453
 
@@ -461,8 +476,7 @@ Notables:
461
476
 
462
477
  ---
463
478
 
464
- # Class config_item (config_file=None, remap_logdirbase=True, force_str=False, secondary_config=False) - Create a configuration instance
465
-
479
+ # Class config_item (config_file=None, remap_logdirbase=True, force_str=False, secondary_config=False, safe_mode=False) - Create a configuration instance
466
480
  The config_item() class provides handling of one or more config file instances. Class methods include:
467
481
  - Config file loading and reloading - `loadconfig()`
468
482
  - Loading config data from strings and dictionaries - `read_string()`, `read_dict()`
@@ -490,6 +504,10 @@ then the `core.tool.log_dir_base` will be set to `core.tool.config_dir`.
490
504
  - The primary config file should be loaded first before any secondary_config loads, so that logging
491
505
  is properly set up.
492
506
 
507
+ `safe_mode` (bool, default False)
508
+ - If `safe_mode=True` then timeouts are enforced when checking for config files.
509
+ - If `safe_mode=False` then checks for the existence of config files runs the risk of application hang.
510
+ - See Behavior NOTE below.
493
511
 
494
512
  ### Useful class attributes
495
513
  The current values of all public class attributes may be printed using `print(my_config)`.
@@ -521,26 +539,44 @@ instantiation `config_file` is a relative path (uses mungePath)
521
539
 
522
540
 
523
541
  ### Behaviors and rules
524
- - More than one `config_item()` may be created and loaded. This allows for configuration data to be partitioned
542
+ 1. More than one `config_item()` may be created and loaded. This allows for configuration data to be partitioned
525
543
  as desired. Each defined config is loaded to its own instance-specific `cfg` dictionary. Only one config_item()
526
544
  instance should be considered the primary, while other instances should be tagged with `secondary_config=True`.
527
545
  Logging setups are controlled only by the primary config instance.
528
546
  Also see the loadconfig() `import` feature.
529
- - Initially in _user_ mode, after the `set_toolname()` call, `core.tool.log_dir_base`
547
+
548
+ 1. NOTE: On Linux the cost of `safe_mode=True` when searching for a quickly found config file is negligible
549
+ (Linux uses process fork), but on Windows (uses process spawn) the minimum execution time for a file
550
+ existence check can be 1 to 2 seconds. When `safe_mode=False` and the config file is on a network share
551
+ drive, the file existence check can cause a indefinite blocking hang of your tool script if the network
552
+ goes down (true for both Linux and Windows). So, use `safe_mode=False` if your config files are on a local
553
+ drive, and use `safe_mode=True` if your config files are on a network drive. Recognize that on Windows
554
+ this will perhaps cause significant delays.
555
+
556
+ 1. Initially in _user_ mode, after the `set_toolname()` call, `core.tool.log_dir_base`
530
557
  (the log directory) is set to the `core.tool.user_data_dir`.
531
558
  Once `config_item()` is called the `core.tool.log_dir_base` is _remapped_ to
532
559
  `core.tool.config_dir`. This is the author's style preference (centralize primary files, and
533
560
  reduce spreading files around the file system).
534
561
  To disable this remap, in the `config_item()` call set `remap_logdirbase=False`.
535
562
  This remapping is not done in site mode.
536
- - A different log base directory may be set by user code by setting `core.tool.log_dir_base` to a different
563
+
564
+ 1. A different log base directory may be set by user code by setting `core.tool.log_dir_base` to a different
537
565
  path after the `set_toolname()` call and before the `config_item()` call, for example
538
566
  `core.tool.log_dir_base = "/var/log"` may be desirable in site mode.
539
- - A different config directory may be set by user code by setting `core.tool.config_dir` to a different
567
+
568
+ 1. A different config directory may be set by user code by setting `core.tool.config_dir` to a different
540
569
  path after the `set_toolname()` call and before the `config_item()` call, for example
541
570
  `core.tool.config_dir = core.tool.main_dir` sets the config dir to the same as the tool script's
542
571
  directory. With `remap_logdirbase=True`, the log dir will also be set to the tool script's directory.
543
- - Details of the configuration instance may be printed, eg, `print(my_config)`.
572
+
573
+ 1. Details of the configuration instance may be printed, eg, `print(my_config)`.
574
+
575
+ 1. Logging of the operations within loadconfig() and (other configman methods) may be controlled with setting
576
+ the named child logger `cjnfuncs.configman` to INFO or DEBUG level (the default logging level is WARNING which
577
+ produces no logging events from this module), eg:
578
+
579
+ logging.getLogger('cjnfuncs.configman').setLevel(logging.INFO)
544
580
 
545
581
  <br/>
546
582
 
@@ -551,7 +587,6 @@ directory. With `remap_logdirbase=True`, the log dir will also be set to the to
551
587
  # loadconfig () - Load a configuration file into the cfg dictionary
552
588
  ```
553
589
  loadconfig(
554
- ldcfg_ll = 30,
555
590
  call_logfile = None,
556
591
  call_logfile_wins = False,
557
592
  flush_on_reload = False,
@@ -573,9 +608,6 @@ feature, and intermittent loss of access to the config file.
573
608
 
574
609
 
575
610
  ### Args
576
- `ldcfg_ll` (int, default 30 (WARNING))
577
- - Logging level used within `loadconfig()` code for debugging loadconfig() itself
578
-
579
611
  `call_logfile` (Path or str, default None)
580
612
  - If `call_logfile` is passed on the loadconfig() call, and `call_logfile_wins=True`, then any `LogFile`
581
613
  specified in the config file is overridden. This feature allows for interactive usage modes where
@@ -613,90 +645,92 @@ regardless of whether the config file timestamp has changed
613
645
 
614
646
 
615
647
  ### Behaviors and rules
616
- - See `getcfg()`, below, for accessing loaded config data. The class instance-specific `cfg` dictionary may be
648
+ 1. See `getcfg()`, below, for accessing loaded config data. The class instance-specific `cfg` dictionary may be
617
649
  directly accessed as well.
618
650
 
619
- - The format of a config file is param=value pairs.
620
- - Separating the param and value_portion may be whitespace, `=` or `:` (multiples allowed).
621
- - Param names can contain all valid characters, except the separators or `#`, and cannot start with `[`.
651
+ 1. The format of a config file is param=value pairs.
652
+ - Separating the param and value_portion may be whitespace, `=` or `:` (multiples allowed).
653
+ - Param names can contain all valid characters, except the separators or `#`, and cannot start with `[`.
622
654
 
623
- - Sections and a DEFAULT section are supported. Section name are enclosed in `[ ]`.
624
- - Leading and trailing whitespace is trimmed off of the section name, and embedded whitespace is retained.
655
+ 1. Sections and a DEFAULT section are supported. Section name are enclosed in `[ ]`.
656
+ - Leading and trailing whitespace is trimmed off of the section name, and embedded whitespace is retained.
625
657
  EG: `[ hello my name is Fred ]` becomes section name `'hello my name is Fred'`.
626
- - Section names can contain most all characters, except `]`.
658
+ - Section names can contain most all characters, except `]`.
627
659
 
628
- - **Native int, float, bool, list, tuple, dict, str support** - Bool true/false is case insensitive. A str
660
+ 1. **Native int, float, bool, list, tuple, dict, str support** - Bool true/false is case insensitive. A str
629
661
  type is stored in the `cfg` dictionary if none of the other types can be resolved for a given value_portion.
630
662
  Automatic typing avoids most explicit type casting clutter in the tool script. Be careful to error trap
631
663
  for type errors (eg, expecting a float but user input error resulted in a str). Also see the
632
664
  getcfg() `types=[]` arg for basic type enforcement.
633
665
 
634
- - **Quoted strings** - If a value_portion cannot be resolved to a Python native type then it is loaded as a str,
666
+ 1. **Quoted strings** - If a value_portion cannot be resolved to a Python native type then it is loaded as a str,
635
667
  eg `My_name = George` loads George as a str. A value_portion may be forced to be loaded as a str by using
636
668
  quotes, eg `Some_number_as_str = "2.54"` forces the value_portion to be loaded as a str rather than a float. Supported
637
669
  quote types: `"..."`, `'...'`, (triple-double quotes), and `'''...'''`. `My_name = George`,
638
670
  `My_name : "George"`, `My_name '''George'''`, etc., are identical when loaded.
639
671
  Quoted strings may contain all valid characters, including '#' which normally starts a comment.
640
672
 
641
- - **Multi-line values** - A param's value_portion may be specified over multiple lines for readability by placing
673
+ 1. **Multi-line values** - A param's value_portion may be specified over multiple lines for readability by placing
642
674
  the `\` line continuation character as the last non-whitespace character on the line before any comment.
643
675
  The parser strips comments and leading/trailing whitespace, then concatenates the multi-line value_portion segments
644
676
  into a single line (single space separated) in the loaded config. Comments may be placed on each line.
645
677
  NOTE: For a multi-line param that will be loaded as a str, avoid using quotes as results may be strange.
646
678
 
647
- - **Logging setup** - `loadconfig()` calls `cjnfuncs.core.setuplogging()`. The `logging` handle is available for
679
+ 1. **Logging setup** - `loadconfig()` calls `cjnfuncs.core.setuplogging()`. The `logging` handle is available for
648
680
  import by other modules (`from cjnfuncs.core import logging`). By default, logging will go to the
649
681
  console (stdout) filtered at the WARNING/30 level. Don't call `setuplogging()` directly if using loadconfig().
650
682
 
651
- - **Logging level control** - Optional `LogLevel` in the primary config file will set the logging level after
683
+ 1. **Logging level control** - Optional `LogLevel` in the primary config file will set the root logging level after
652
684
  the config file has been loaded. If LogLevel is not specified in the primary config file, then
653
- the logging level is left unchanged (the Python default logging level, 30/WARNING).
654
- The tool script code may also manually/explicitly set the logging level _after the initial `loadconifig()` call_
685
+ the root logging level is left unchanged (the Python default logging level is 30/WARNING).
686
+ The tool script code may also manually/explicitly set the root logging level _after the initial `loadconifig()` call_
655
687
  and this value will be retained over later calls to loadconfig, thus allowing for a command line `--verbose`
656
- switch feature. Note that logging done _within_ loadconfig() code is always done at the `ldcfg_ll` level.
688
+ switch feature. Note that logging done _within_ loadconfig() uses the `cjnfuncs.configmap` child/named logger.
689
+ `logging.getLogger('cjnfuncs.configman').setLevel(logging.INFO)` (or DEBUG) enables diagnostic logging from
690
+ loadconfig.
657
691
 
658
- - **Log file options** - Where to log has two separate fields: `call_logifle` in the call to loadconfig(), and
692
+ 1. **Log file options** - Where to log has two separate fields: `call_logifle` in the call to loadconfig(), and
659
693
  `LogFile` in the loaded primary config file, with `call_logfile_wins` selecting which is used. This mechanism allows for
660
694
  a command line `--log-file` switch to override a _default_ log file defined in the config file. If the selected
661
695
  logging location is `None` then output goes to the console (stdout).
662
696
 
663
- call_logfile_wins | call_logfile | Config LogFile | Results
664
- --|--|--|--
665
- False (default) | ignored | None (default) | Console
666
- False (default) | ignored | file_path | To the config LogFile
667
- True | None (default) | ignored | Console
668
- True | file_path | ignored | To the call_logfile
697
+ call_logfile_wins | call_logfile | Config LogFile | Results
698
+ --|--|--|--
699
+ False (default) | ignored | None (default) | Console
700
+ False (default) | ignored | file_path | To the config LogFile
701
+ True | None (default) | ignored | Console
702
+ True | file_path | ignored | To the call_logfile
669
703
 
670
- - **Logging format** - cjnfuncs has default format strings for console and file logging.
704
+ 1. **Logging format** - cjnfuncs has default format strings for console and file logging.
671
705
  These defaults may be overridden by defining `ConsoleLogFormat` and/or `FileLogFormat`
672
706
  in the config file.
673
707
 
674
- - **Import nested config files** - loadconfig() supports `Import` (case insensitive). The imported file path
708
+ 1. **Import nested config files** - loadconfig() supports `Import` (case insensitive). The imported file path
675
709
  is relative to the `core.tool.config_dir`, if not an absolute path.
676
710
  The specified file is imported as if the params were in the main config file. Nested imports are allowed.
677
711
  Sections are not allowed within an imported file - only in the main/top-level config file.
678
712
  A prime usage of `import` is to place email server credentials in your home directory with user-only readability,
679
713
  then import them in the tool script config file as such: `import ~/creds_SMTP`.
680
714
 
681
- - **Config reload if changed, `flush_on_reload`, and `force_flush_reload`** - loadconfig() may be called
715
+ 1. **Config reload if changed, `flush_on_reload`, and `force_flush_reload`** - loadconfig() may be called
682
716
  periodically by the tool script, such as in a service loop.
683
717
  If the config file timestamp is unchanged then loadconfig() immediately returns `0`.
684
718
  If the timestamp has changed then the config file will be reloaded and `1` is returned to indicate to
685
719
  the tool script to do any post-config-load operations.
686
- - If `flush_on_reload=True` (default False) then the instance-specific `cfg` dictionary
720
+ - If `flush_on_reload=True` (default False) then the instance-specific `cfg` dictionary
687
721
  will be cleaned/purged before the config file is reloaded. If `flush_on_reload=False` then the config
688
722
  file will be reloaded on top of the existing `cfg` dictionary contents (if a param was
689
723
  deleted in the config
690
724
  file it will still exist in `cfg` after the reload). [lanmonitor](https://github.com/cjnaz/lanmonitor) uses the
691
725
  `flush_on_reload=True` feature.
692
- - `force_flush_reload=True` (default False) forces both a clear/flush of the `cfg` dictionary and then a fresh
726
+ - `force_flush_reload=True` (default False) forces both a clear/flush of the `cfg` dictionary and then a fresh
693
727
  reload of the config file.
694
- - **Note** that if using threading then a thread should be paused while the config file
728
+ - **Note** that if using threading then a thread should be paused while the config file
695
729
  is being reloaded with `flush_on_reload=True` or `force_flush_reload=True` since the params will disappear briefly.
696
730
  Use the `prereload_callback` mechanism to manage any code dependencies before the cfg dictionary is purged.
697
- - Changes to imported files are not tracked for changes.
731
+ - Changes to imported files are not tracked for changes.
698
732
 
699
- - **Tolerating intermittent config file access** - When implementing a service loop, if `tolerate_missing=True`
733
+ 1. **Tolerating intermittent config file access** - When implementing a service loop, if `tolerate_missing=True`
700
734
  (default False) then loadconfig() will return `-1` if the config file cannot be accessed, informing the
701
735
  tool script of the problem for appropriate handling (typically logging the event then ignoring the problem for
702
736
  the current iteration). If `tolerate_missing=False` then loadconfig() will raise a ConfigError if the config file
@@ -731,12 +765,6 @@ flush_on_reload, force_flush_reload, and tolerate_missing.
731
765
  ### Returns
732
766
  - A ConfigError is raised if there are parsing issues
733
767
  - A ConfigError is also raised if an imported config file cannot accessed
734
-
735
-
736
- ### Behaviors and rules
737
- - read_string() does not modify the logging level (ldcfg_ll is not an arg). If called from user code,
738
- the logging level will be as set in the user code. Logging statements within read_string() is at the debug level.
739
- - See loadconfig() for config loading Behaviors and rules.
740
768
 
741
769
  <br/>
742
770
 
@@ -768,23 +796,25 @@ Loaded content is added to and/or modifies any previously loaded content.
768
796
  ```
769
797
  new_config = config_item() # config need not be associated with a file
770
798
 
771
- main_contents = {
799
+ main_contents = {
772
800
  'a' : 6,
773
801
  'b' : 7.0,
774
802
  'c' : [6, 7.0, 42, 'hi']
775
803
  }
804
+ new_config.read_dict(main_contents)
805
+
776
806
  sect_contents = {
777
807
  'd' : ('hi', 'there'),
778
808
  'e' : {'hi':'Hi!', 'there':'There!'},
779
809
  'f' : [6, 7.0, 42, 'hi']
780
810
  }
811
+ new_config.read_dict(sect_contents, 'A section')
812
+
781
813
  def_contents = {
782
814
  'g' : 'Hi',
783
815
  'h' : True,
784
816
  'i' : False
785
817
  }
786
- new_config.read_dict(main_contents)
787
- new_config.read_dict(sect_contents, 'A section')
788
818
  new_config.read_dict(def_contents, 'DEFAULT')
789
819
  ```
790
820