cimhub-gridlabd 2.0.0a1__tar.gz

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (173) hide show
  1. cimhub_gridlabd-2.0.0a1/PKG-INFO +110 -0
  2. cimhub_gridlabd-2.0.0a1/README.md +89 -0
  3. cimhub_gridlabd-2.0.0a1/pyproject.toml +52 -0
  4. cimhub_gridlabd-2.0.0a1/setup.cfg +4 -0
  5. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/__init__.py +3 -0
  6. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/__init__.py +10 -0
  7. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/base/__init__.py +1 -0
  8. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/base/node.py +220 -0
  9. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/cim_to_glm.py +232 -0
  10. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/generators/__init__.py +14 -0
  11. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/generators/battery.py +66 -0
  12. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/generators/inverter.py +237 -0
  13. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/generators/machine.py +180 -0
  14. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/generators/machine_dynamics.py +100 -0
  15. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/generators/solar.py +49 -0
  16. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/glm_registry.py +8 -0
  17. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/glm_text_writer.py +323 -0
  18. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/glm_writer.py +167 -0
  19. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/lines/__init__.py +9 -0
  20. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/lines/line.py +205 -0
  21. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/lines/line_configuration.py +299 -0
  22. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/lines/line_spacing.py +245 -0
  23. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/lines/underground_line_conductor.py +257 -0
  24. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/loads/__init__.py +1 -0
  25. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/loads/load.py +210 -0
  26. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/shunts/__init__.py +2 -0
  27. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/shunts/capacitor.py +72 -0
  28. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/switches/__init__.py +3 -0
  29. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/switches/_common.py +98 -0
  30. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/switches/fuse.py +32 -0
  31. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/switches/recloser.py +32 -0
  32. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/switches/switch.py +35 -0
  33. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/transformers/__init__.py +6 -0
  34. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/transformers/regulator.py +345 -0
  35. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/transformers/transformer.py +146 -0
  36. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/transformers/transformer_configuration.py +520 -0
  37. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/utils/__init__.py +4 -0
  38. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/utils/phasing.py +163 -0
  39. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/exporter/utils/ratings.py +36 -0
  40. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/importer/__init__.py +15 -0
  41. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/importer/base/__init__.py +15 -0
  42. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/importer/base/node.py +87 -0
  43. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/importer/base/substation.py +47 -0
  44. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/importer/base/triplex_node.py +52 -0
  45. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/importer/capacitors/__init__.py +2 -0
  46. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/importer/capacitors/capacitor.py +93 -0
  47. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/importer/common.py +105 -0
  48. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/importer/glm_reader.py +495 -0
  49. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/importer/glm_registry.py +7 -0
  50. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/importer/glm_serialization.py +219 -0
  51. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/importer/glm_text_reader.py +346 -0
  52. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/importer/glm_to_cim.py +212 -0
  53. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/importer/lines/__init__.py +13 -0
  54. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/importer/lines/_wire_assembly.py +90 -0
  55. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/importer/lines/line_configuration.py +56 -0
  56. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/importer/lines/line_spacing.py +59 -0
  57. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/importer/lines/overhead_line.py +47 -0
  58. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/importer/lines/overhead_line_conductor.py +33 -0
  59. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/importer/lines/triplex_line.py +62 -0
  60. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/importer/lines/underground_line.py +37 -0
  61. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/importer/lines/underground_line_conductor.py +45 -0
  62. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/importer/loads/__init__.py +2 -0
  63. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/importer/loads/load.py +63 -0
  64. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/importer/switches/__init__.py +2 -0
  65. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/importer/switches/switch.py +31 -0
  66. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/importer/transformers/__init__.py +4 -0
  67. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/importer/transformers/regulator.py +128 -0
  68. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/importer/transformers/transformer.py +164 -0
  69. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/importer/transformers/transformer_configuration.py +161 -0
  70. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/cpp_parser.py +269 -0
  71. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/gridlabd.py +27136 -0
  72. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/_directives/define.yaml +19 -0
  73. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/_directives/set.yaml +19 -0
  74. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/generators/battery.yaml +780 -0
  75. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/generators/central_dg_control.yaml +112 -0
  76. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/generators/controller_dg.yaml +262 -0
  77. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/generators/diesel_dg.yaml +2881 -0
  78. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/generators/energy_storage.yaml +244 -0
  79. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/generators/inverter.yaml +2708 -0
  80. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/generators/inverter_dyn.yaml +2087 -0
  81. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/generators/rectifier.yaml +190 -0
  82. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/generators/solar.yaml +645 -0
  83. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/generators/sync_ctrl.yaml +297 -0
  84. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/generators/windturb_dg.yaml +1075 -0
  85. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/main.yaml +115 -0
  86. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/billdump.yaml +73 -0
  87. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/capacitor.yaml +376 -0
  88. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/currdump.yaml +72 -0
  89. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/emissions.yaml +1069 -0
  90. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/fault_check.yaml +89 -0
  91. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/fuse.yaml +103 -0
  92. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/impedance_dump.yaml +63 -0
  93. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/jsondump.yaml +133 -0
  94. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/line.yaml +111 -0
  95. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/line_configuration.yaml +312 -0
  96. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/line_spacing.yaml +148 -0
  97. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/link.yaml +711 -0
  98. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/load.yaml +1470 -0
  99. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/load_tracker.yaml +111 -0
  100. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/meter.yaml +1248 -0
  101. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/motor.yaml +893 -0
  102. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/node.yaml +1170 -0
  103. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/overhead_line.yaml +31 -0
  104. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/overhead_line_conductor.yaml +118 -0
  105. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/performance_motor.yaml +407 -0
  106. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/power_metrics.yaml +193 -0
  107. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/powerflow_object.yaml +112 -0
  108. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/pqload.yaml +603 -0
  109. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/recloser.yaml +68 -0
  110. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/regulator.yaml +168 -0
  111. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/regulator_configuration.yaml +306 -0
  112. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/restoration.yaml +163 -0
  113. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/sectionalizer.yaml +31 -0
  114. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/series_compensator.yaml +549 -0
  115. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/series_reactor.yaml +144 -0
  116. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/substation.yaml +297 -0
  117. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/switch.yaml +109 -0
  118. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/sync_check.yaml +372 -0
  119. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/transformer.yaml +230 -0
  120. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/transformer_configuration.yaml +512 -0
  121. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/triplex_line.yaml +31 -0
  122. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/triplex_line_conductor.yaml +106 -0
  123. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/triplex_line_configuration.yaml +187 -0
  124. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/triplex_load.yaml +729 -0
  125. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/triplex_meter.yaml +812 -0
  126. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/triplex_node.yaml +822 -0
  127. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/underground_line.yaml +31 -0
  128. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/underground_line_conductor.yaml +236 -0
  129. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/vfd.yaml +156 -0
  130. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/volt_var_control.yaml +217 -0
  131. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/powerflow/voltdump.yaml +82 -0
  132. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/residential/ZIPload.yaml +372 -0
  133. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/residential/appliance.yaml +83 -0
  134. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/residential/clotheswasher.yaml +596 -0
  135. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/residential/dishwasher.yaml +882 -0
  136. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/residential/dryer.yaml +601 -0
  137. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/residential/evcharger.yaml +192 -0
  138. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/residential/evcharger_det.yaml +557 -0
  139. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/residential/freezer.yaml +179 -0
  140. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/residential/house.yaml +2171 -0
  141. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/residential/house_a.yaml +480 -0
  142. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/residential/lights.yaml +122 -0
  143. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/residential/microwave.yaml +126 -0
  144. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/residential/occupantload.yaml +68 -0
  145. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/residential/plugload.yaml +82 -0
  146. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/residential/range.yaml +711 -0
  147. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/residential/refrigerator.yaml +598 -0
  148. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/residential/thermal_storage.yaml +212 -0
  149. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/residential/waterheater.yaml +640 -0
  150. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml/types/common.yaml +2014 -0
  151. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/linkml_generator.py +496 -0
  152. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd/schema/property_parser.py +460 -0
  153. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd.egg-info/PKG-INFO +110 -0
  154. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd.egg-info/SOURCES.txt +171 -0
  155. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd.egg-info/dependency_links.txt +1 -0
  156. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd.egg-info/requires.txt +2 -0
  157. cimhub_gridlabd-2.0.0a1/src/cimhub_gridlabd.egg-info/top_level.txt +1 -0
  158. cimhub_gridlabd-2.0.0a1/tests/test_api_conformance.py +88 -0
  159. cimhub_gridlabd-2.0.0a1/tests/test_connectivity_node.py +161 -0
  160. cimhub_gridlabd-2.0.0a1/tests/test_glm_cim_glm.py +216 -0
  161. cimhub_gridlabd-2.0.0a1/tests/test_glm_importer.py +324 -0
  162. cimhub_gridlabd-2.0.0a1/tests/test_glm_json_roundtrip.py +417 -0
  163. cimhub_gridlabd-2.0.0a1/tests/test_glm_node.py +184 -0
  164. cimhub_gridlabd-2.0.0a1/tests/test_glm_text_reader.py +326 -0
  165. cimhub_gridlabd-2.0.0a1/tests/test_golden_diff.py +132 -0
  166. cimhub_gridlabd-2.0.0a1/tests/test_ieee13_roundtrip.py +393 -0
  167. cimhub_gridlabd-2.0.0a1/tests/test_line_ratings.py +147 -0
  168. cimhub_gridlabd-2.0.0a1/tests/test_machine_exporter.py +207 -0
  169. cimhub_gridlabd-2.0.0a1/tests/test_phase_impedance_config.py +139 -0
  170. cimhub_gridlabd-2.0.0a1/tests/test_regulator_exporter.py +292 -0
  171. cimhub_gridlabd-2.0.0a1/tests/test_schema_consistency.py +449 -0
  172. cimhub_gridlabd-2.0.0a1/tests/test_units_correctness.py +181 -0
  173. cimhub_gridlabd-2.0.0a1/tests/test_z_emit_order.py +55 -0
@@ -0,0 +1,110 @@
1
+ Metadata-Version: 2.4
2
+ Name: cimhub_gridlabd
3
+ Version: 2.0.0a1
4
+ Summary: CIMHub GridLAB-D Library
5
+ Author-email: Pacific Northwest National Laboratory <gridappsd@pnnl.gov>
6
+ License: BSD-2-Clause
7
+ Project-URL: Homepage, https://github.com/PNNL-CIM-Tools/CIMHub_2_0
8
+ Project-URL: Bug Tracker, https://github.com/PNNL-CIM-Tools/CIMHub_2_0/issues
9
+ Project-URL: Documentation, https://cimhub-gridlabd.readthedocs.io/
10
+ Classifier: Programming Language :: Python :: 3
11
+ Classifier: Operating System :: OS Independent
12
+ Classifier: Environment :: Console
13
+ Classifier: Development Status :: 3 - Alpha
14
+ Classifier: Intended Audience :: Science/Research
15
+ Classifier: License :: OSI Approved :: BSD License
16
+ Classifier: Topic :: Scientific/Engineering
17
+ Requires-Python: >=3.10
18
+ Description-Content-Type: text/markdown
19
+ Requires-Dist: cimhub_core~=2.0.0a2
20
+ Requires-Dist: pandas>=2.3.3
21
+
22
+ # cimhub_gridlabd
23
+
24
+ Bidirectional converter between GridLAB-D (GLM) and CIM (IEC 61968/61970) using the `cimhub_2026` profile.
25
+
26
+ ## Usage
27
+
28
+ ### GLM to CIM (Import)
29
+
30
+ ```python
31
+ import os
32
+ os.environ['CIMG_USE_UNITS'] = 'TRUE'
33
+ os.environ['CIMG_CIM_PROFILE'] = 'cimhub_2026'
34
+
35
+ from cimhub_gridlabd.importer.glm_to_cim import glm_to_cim
36
+
37
+ feeder = glm_to_cim("/path/to/IEEE13.glm")
38
+ ```
39
+
40
+ ### CIM to GLM (Export)
41
+
42
+ Export is two steps: build the GLM model, then write it.
43
+
44
+ ```python
45
+ from cimhub_gridlabd.exporter.cim_to_glm import GlmExporter
46
+ from cimhub_gridlabd.exporter.glm_text_writer import GlmTextWriter
47
+
48
+ glm_model = GlmExporter().to_model(feeder)
49
+ GlmTextWriter().write(glm_model, "/path/to/IEEE13.glm")
50
+ ```
51
+
52
+ `to_model` returns an in-memory `GraphModel` of GLM dataclasses, so you can
53
+ inspect or edit the model before it is serialized.
54
+
55
+ ### JSON variant
56
+
57
+ Swap in the GLM-JSON writer (one object per JSON entry, grouped by class):
58
+
59
+ ```python
60
+ from cimhub_gridlabd.exporter.cim_to_glm import GlmExporter
61
+ from cimhub_gridlabd.exporter.glm_writer import GlmJsonWriter
62
+
63
+ glm_model = GlmExporter().to_model(feeder)
64
+ GlmJsonWriter().write(glm_model, "/path/to/IEEE13.json")
65
+ ```
66
+
67
+ Or use the one-line convenience wrapper:
68
+
69
+ ```python
70
+ from cimhub_gridlabd.exporter.cim_to_glm import cim_to_glm_json
71
+
72
+ cim_to_glm_json(feeder, "/path/to/IEEE13.json")
73
+ ```
74
+
75
+ ## Architecture
76
+
77
+ The package follows the standard CIMHub four-layer pipeline:
78
+
79
+ ```
80
+ LinkML YAML → glm_schema.py → GraphModel → GlmReader / GlmWriter
81
+ ↕
82
+ GlmImporter / GlmExporter
83
+ ```
84
+
85
+ The writer is annotation-driven: LinkML slot annotations (`native_name`, `glm_unit`, etc.) control how each CIM field maps to a GLM attribute without hard-coded per-class logic. See `GLM_LINKML_ARCHITECTURE.md` for the full design.
86
+
87
+ ## Equipment Coverage
88
+
89
+ | Element | Import | Export |
90
+ |---|---|---|
91
+ | Overhead lines (geometry) | ✓ | ✓ |
92
+ | Underground cables | ✓ | ✓ |
93
+ | Transformers | ✓ | ✓ |
94
+ | Regulators | ✓ | ✓ |
95
+ | Capacitor banks | ✓ | ✓ |
96
+ | Loads | ✓ | ✓ |
97
+ | Switches / reclosers / fuses | ✓ | ✓ |
98
+ | DER (PV, battery) | partial | partial |
99
+
100
+ ## Running Tests
101
+
102
+ ```bash
103
+ uv run pytest cimhub_gridlabd/tests/ -v
104
+ ```
105
+
106
+ ## Notes
107
+
108
+ - **Never substitute a computed impedance matrix for conductor geometry.** When `WireSpacingInfo` is present, export it as native GridLAB-D `line_spacing` + `overhead_line_conductor` objects. See `cimhub_core/development/CONDUCTOR_GEOMETRY_ANTI_PATTERNS.md`.
109
+ - Python complex literals (`+0.79+0.43j`) are not valid GLM syntax — the writer uses explicit `r` / `x` fields.
110
+ - Phase lookups must traverse from `ACLineSegment.ACLineSegmentPhases`, not from `WireSpacingInfo.ACLineSegment[0]` (that list can be empty).
@@ -0,0 +1,89 @@
1
+ # cimhub_gridlabd
2
+
3
+ Bidirectional converter between GridLAB-D (GLM) and CIM (IEC 61968/61970) using the `cimhub_2026` profile.
4
+
5
+ ## Usage
6
+
7
+ ### GLM to CIM (Import)
8
+
9
+ ```python
10
+ import os
11
+ os.environ['CIMG_USE_UNITS'] = 'TRUE'
12
+ os.environ['CIMG_CIM_PROFILE'] = 'cimhub_2026'
13
+
14
+ from cimhub_gridlabd.importer.glm_to_cim import glm_to_cim
15
+
16
+ feeder = glm_to_cim("/path/to/IEEE13.glm")
17
+ ```
18
+
19
+ ### CIM to GLM (Export)
20
+
21
+ Export is two steps: build the GLM model, then write it.
22
+
23
+ ```python
24
+ from cimhub_gridlabd.exporter.cim_to_glm import GlmExporter
25
+ from cimhub_gridlabd.exporter.glm_text_writer import GlmTextWriter
26
+
27
+ glm_model = GlmExporter().to_model(feeder)
28
+ GlmTextWriter().write(glm_model, "/path/to/IEEE13.glm")
29
+ ```
30
+
31
+ `to_model` returns an in-memory `GraphModel` of GLM dataclasses, so you can
32
+ inspect or edit the model before it is serialized.
33
+
34
+ ### JSON variant
35
+
36
+ Swap in the GLM-JSON writer (one object per JSON entry, grouped by class):
37
+
38
+ ```python
39
+ from cimhub_gridlabd.exporter.cim_to_glm import GlmExporter
40
+ from cimhub_gridlabd.exporter.glm_writer import GlmJsonWriter
41
+
42
+ glm_model = GlmExporter().to_model(feeder)
43
+ GlmJsonWriter().write(glm_model, "/path/to/IEEE13.json")
44
+ ```
45
+
46
+ Or use the one-line convenience wrapper:
47
+
48
+ ```python
49
+ from cimhub_gridlabd.exporter.cim_to_glm import cim_to_glm_json
50
+
51
+ cim_to_glm_json(feeder, "/path/to/IEEE13.json")
52
+ ```
53
+
54
+ ## Architecture
55
+
56
+ The package follows the standard CIMHub four-layer pipeline:
57
+
58
+ ```
59
+ LinkML YAML → glm_schema.py → GraphModel → GlmReader / GlmWriter
60
+ ↕
61
+ GlmImporter / GlmExporter
62
+ ```
63
+
64
+ The writer is annotation-driven: LinkML slot annotations (`native_name`, `glm_unit`, etc.) control how each CIM field maps to a GLM attribute without hard-coded per-class logic. See `GLM_LINKML_ARCHITECTURE.md` for the full design.
65
+
66
+ ## Equipment Coverage
67
+
68
+ | Element | Import | Export |
69
+ |---|---|---|
70
+ | Overhead lines (geometry) | ✓ | ✓ |
71
+ | Underground cables | ✓ | ✓ |
72
+ | Transformers | ✓ | ✓ |
73
+ | Regulators | ✓ | ✓ |
74
+ | Capacitor banks | ✓ | ✓ |
75
+ | Loads | ✓ | ✓ |
76
+ | Switches / reclosers / fuses | ✓ | ✓ |
77
+ | DER (PV, battery) | partial | partial |
78
+
79
+ ## Running Tests
80
+
81
+ ```bash
82
+ uv run pytest cimhub_gridlabd/tests/ -v
83
+ ```
84
+
85
+ ## Notes
86
+
87
+ - **Never substitute a computed impedance matrix for conductor geometry.** When `WireSpacingInfo` is present, export it as native GridLAB-D `line_spacing` + `overhead_line_conductor` objects. See `cimhub_core/development/CONDUCTOR_GEOMETRY_ANTI_PATTERNS.md`.
88
+ - Python complex literals (`+0.79+0.43j`) are not valid GLM syntax — the writer uses explicit `r` / `x` fields.
89
+ - Phase lookups must traverse from `ACLineSegment.ACLineSegmentPhases`, not from `WireSpacingInfo.ACLineSegment[0]` (that list can be empty).
@@ -0,0 +1,52 @@
1
+ [build-system]
2
+ requires = ["setuptools~=80.9"]
3
+ build-backend = "setuptools.build_meta"
4
+
5
+ [project]
6
+ name = "cimhub_gridlabd"
7
+ description = "CIMHub GridLAB-D Library"
8
+ readme = "README.md"
9
+ version = "2.0.0a1"
10
+ requires-python = ">=3.10"
11
+ license = { text = "BSD-2-Clause" }
12
+ authors = [
13
+ { name = "Pacific Northwest National Laboratory", email = "gridappsd@pnnl.gov" }
14
+ ]
15
+ classifiers = [
16
+ "Programming Language :: Python :: 3",
17
+ "Operating System :: OS Independent",
18
+ "Environment :: Console",
19
+ "Development Status :: 3 - Alpha",
20
+ "Intended Audience :: Science/Research",
21
+ "License :: OSI Approved :: BSD License",
22
+ "Topic :: Scientific/Engineering",
23
+ ]
24
+ dependencies = [
25
+ "cimhub_core ~=2.0.0a2",
26
+ "pandas>=2.3.3",
27
+ ]
28
+
29
+ [project.urls]
30
+ "Homepage" = "https://github.com/PNNL-CIM-Tools/CIMHub_2_0"
31
+ "Bug Tracker" = "https://github.com/PNNL-CIM-Tools/CIMHub_2_0/issues"
32
+ "Documentation" = "https://cimhub-gridlabd.readthedocs.io/"
33
+
34
+ [tool.pytest.ini_options]
35
+ testpaths = ["tests"]
36
+ addopts = "-ra -q"
37
+
38
+ [tool.coverage.report]
39
+ skip_empty = true
40
+
41
+ [tool.mypy]
42
+ strict = false
43
+ ignore_missing_imports = false
44
+ disallow_untyped_defs = false
45
+ warn_unused_ignores = true
46
+ warn_unreachable = true
47
+
48
+ [tool.setuptools]
49
+ packages = { find = { where = ["src"] } }
50
+
51
+ [tool.setuptools.package-data]
52
+ "*" = ["*.json", "*.yaml"]
@@ -0,0 +1,4 @@
1
+ [egg_info]
2
+ tag_build =
3
+ tag_date = 0
4
+
@@ -0,0 +1,3 @@
1
+ """CIMHub GridLAB-D — bidirectional GridLAB-D ↔ CIM converter."""
2
+
3
+ __version__ = "2.0.0a0"
@@ -0,0 +1,10 @@
1
+ from cimhub_gridlabd.exporter.glm_writer import GlmJsonWriter
2
+
3
+ __all__ = ["GlmJsonWriter"]
4
+
5
+ # CIM conversion functions require cimgraph — only export when available
6
+ try:
7
+ from cimhub_gridlabd.exporter.cim_to_glm import cim_to_glm, cim_to_glm_json # noqa: F401
8
+ __all__ += ["cim_to_glm", "cim_to_glm_json"]
9
+ except ImportError:
10
+ pass
@@ -0,0 +1 @@
1
+ from cimhub_gridlabd.exporter.base.node import convert_connectivity_node
@@ -0,0 +1,220 @@
1
+ from __future__ import annotations
2
+
3
+ import importlib
4
+ import logging
5
+ import math
6
+
7
+ import cimgraph.data_profile.cimhub_2026 as cim
8
+
9
+ from cimhub_core import GraphModel
10
+ from cimhub_gridlabd.schema import gridlabd as glm_schema
11
+ from cimhub_gridlabd.exporter.glm_registry import glm_exporter_registry
12
+ from cimhub_gridlabd.exporter.utils.phasing import collect_phases
13
+
14
+ _log = logging.getLogger(__name__)
15
+
16
+
17
+ def _voltage_from_transformer(terminal, xfmr, cim_mod) -> float | None:
18
+ """Return the rated voltage (V, line-to-line) for this terminal's side of xfmr.
19
+
20
+ Walks PowerTransformerEnds + TransformerTankEnds looking for an end whose
21
+ Terminal matches *terminal*. Returns ``ratedU`` (in V) if found.
22
+ """
23
+ for end in getattr(xfmr, "PowerTransformerEnd", []):
24
+ if getattr(end, "Terminal", None) is terminal:
25
+ v = getattr(end, "ratedU", None)
26
+ if v is not None:
27
+ return float(v)
28
+ for tank in getattr(xfmr, "TransformerTanks", []):
29
+ for end in getattr(tank, "TransformerTankEnds", []):
30
+ if getattr(end, "Terminal", None) is terminal:
31
+ v = getattr(end, "ratedU", None)
32
+ if v is not None:
33
+ return float(v)
34
+ return None
35
+
36
+
37
+ @glm_exporter_registry.register(cim.ConnectivityNode)
38
+ def convert_connectivity_node(node: cim.ConnectivityNode, glm_model: GraphModel) -> dict:
39
+ cim: cim = importlib.import_module(node.__module__)
40
+
41
+ phases = []
42
+ ll_voltages: list[float] = [] # line-to-line (from BaseVoltage) — divide by sqrt(3)
43
+ ln_voltages: list[float] = [] # line-to-neutral (from transformer ratedU) — use as-is
44
+ is_swing_bus = False
45
+ is_swing_pq = False
46
+ is_triplex = False
47
+ glm_node = {}
48
+ glm_node["name"] = node.name or node.uri()
49
+
50
+ # Collect phasing and nominal voltage
51
+ for terminal in node.Terminals:
52
+ equipment = terminal.ConductingEquipment
53
+ if equipment is None:
54
+ continue
55
+
56
+ # Swing bus detection: EnergySource or a regulating network injection.
57
+ # CIM17 calls it EquivalentInjection; CIM18/cimhub_2026 renamed it
58
+ # ExternalNetworkInjection. Match whichever the profile defines.
59
+ injection_cls = getattr(cim, "ExternalNetworkInjection", None) or getattr(
60
+ cim, "EquivalentInjection", None
61
+ )
62
+ if isinstance(equipment, cim.EnergySource):
63
+ is_swing_bus = True
64
+ elif injection_cls is not None and isinstance(equipment, injection_cls):
65
+ if getattr(equipment, "regulationStatus", False):
66
+ is_swing_bus = True
67
+
68
+ if equipment.BaseVoltage is not None:
69
+ # BaseVoltage.nominalVoltage is line-to-line — convert to LN later
70
+ ll_voltages.append(float(equipment.BaseVoltage.nominalVoltage))
71
+ elif isinstance(equipment, cim.PowerTransformer):
72
+ # TransformerEnd.Terminal back-ref may be empty — walk the transformer
73
+ # ends directly and match by terminal to find the rated voltage.
74
+ # TransformerEnd.ratedU is line-to-line for multi-phase ends; for single-
75
+ # phase (center-tap) ends it's line-to-neutral. Both are stored as V.
76
+ # We track these separately so we can later pick the right one.
77
+ v = _voltage_from_transformer(terminal, equipment, cim)
78
+ if v is not None:
79
+ ln_voltages.append(float(v))
80
+ else:
81
+ # For switches/lines with no BaseVoltage, look through the OTHER terminal
82
+ # of the same equipment to its connectivity node's equipment BaseVoltage.
83
+ for other_t in getattr(equipment, "Terminals", []):
84
+ if other_t is terminal:
85
+ continue
86
+ other_cn = getattr(other_t, "ConnectivityNode", None)
87
+ if other_cn is None:
88
+ continue
89
+ for other_t2 in getattr(other_cn, "Terminals", []):
90
+ eq2 = other_t2.ConductingEquipment
91
+ if eq2 is equipment:
92
+ continue
93
+ if getattr(eq2, "BaseVoltage", None) is not None:
94
+ ll_voltages.append(float(eq2.BaseVoltage.nominalVoltage))
95
+ break
96
+ if ll_voltages:
97
+ break
98
+
99
+ phases.append(collect_phases(equipment))
100
+
101
+ # Detect triplex (secondary system) nodes
102
+ if "S" in "".join(phases):
103
+ is_triplex = True
104
+
105
+ # Detect DER types connected to this node — used for sub-meter emission and
106
+ # SWING_PQ classification (matches Java GldNode.bSolarInverters / bStorageInverters
107
+ # / bSyncMachines flags).
108
+ has_pv = False
109
+ has_storage = False
110
+ has_sync = False
111
+ for terminal in node.Terminals:
112
+ eq = terminal.ConductingEquipment
113
+ if isinstance(eq, cim.PowerElectronicsConnection):
114
+ for unit in (eq.PowerElectronicsUnit or []):
115
+ if isinstance(unit, cim.PhotoVoltaicUnit):
116
+ has_pv = True
117
+ elif isinstance(unit, cim.BatteryUnit):
118
+ has_storage = True
119
+ elif isinstance(eq, cim.SynchronousMachine):
120
+ has_sync = True
121
+
122
+ # Assign phases to node. Java appends "N" for primary nodes via GetPhases(false)
123
+ # and "S" for secondary. Python replicates that here.
124
+ sorted_phases = sorted("".join(set(sorted("".join(phases)))))
125
+ if is_triplex:
126
+ # collect_phases already returns the secondary form as "<letter>S", so the
127
+ # letters here may already carry the S — appending another would emit "CSS".
128
+ # GridLAB-D needs "<letter>S" ("CS"), never a bare "S": a bare S compiles
129
+ # but leaves the triplex with no primary phase, which surfaces as wrong
130
+ # secondary voltages at run time rather than as a load-time error.
131
+ letters = "".join(p for p in sorted_phases if p != "S")
132
+ if not letters:
133
+ raise ValueError(
134
+ f"node {node.name}: triplex node has no primary phase letter "
135
+ f"(collected {phases!r}); GridLAB-D requires 'AS'/'BS'/'CS'"
136
+ )
137
+ glm_node["phases"] = letters + "S"
138
+ elif sorted_phases:
139
+ glm_node["phases"] = "".join(sorted_phases) + "N"
140
+ else:
141
+ glm_node["phases"] = "ABCN"
142
+
143
+ # Assign base voltage to node.
144
+ # BaseVoltage.nominalVoltage is line-to-line (LL); divide by sqrt(3) or 2.
145
+ # TransformerEnd.ratedU is used as-is (already LN for the relevant end).
146
+ # Prefer the LL source (more common/reliable) when available.
147
+ ll_to_ln = 2.0 if is_triplex else math.sqrt(3)
148
+ if ll_voltages:
149
+ ln_cand = [v / ll_to_ln for v in set(ll_voltages)]
150
+ elif ln_voltages:
151
+ ln_cand = list(set(ln_voltages))
152
+ else:
153
+ ln_cand = []
154
+
155
+ if len(ln_cand) == 0:
156
+ _log.warning(f"Unable to determine base voltage of Node {node.name}")
157
+ glm_node["nominal_voltage"] = None
158
+ else:
159
+ if len(ln_cand) > 1:
160
+ _log.warning(f"Node {node.name} has multiple voltages; using lowest")
161
+ glm_node["nominal_voltage"] = min(ln_cand)
162
+
163
+ node_name = glm_node["name"]
164
+
165
+ # Convert dict to appropriate GLM schema dataclass
166
+ if is_swing_bus:
167
+ glm_node["bustype"] = "SWING"
168
+ # These values were hard-coded previously, keeping the same
169
+ glm_node["base_power"] = "12MVA"
170
+ glm_node["positive_sequence_voltage"] = "${VSOURCE}"
171
+ glm_node["power_convergence_value"] = "100VA"
172
+ glm_node["outside_comments"] = [f"EnergySource Name:{node.name}"]
173
+
174
+ # Create Substation dataclass instance
175
+ substation = glm_schema.Substation()
176
+ for key, value in glm_node.items():
177
+ setattr(substation, key, value)
178
+ glm_model.add_to_graph(substation)
179
+
180
+ elif is_triplex:
181
+ glm_node["outside_comments"] = [f"Name:{node.name}"]
182
+
183
+ # Create TriplexNode dataclass instance
184
+ triplex_node = glm_schema.TriplexNode()
185
+ for key, value in glm_node.items():
186
+ setattr(triplex_node, key, value)
187
+ glm_model.add_to_graph(triplex_node)
188
+
189
+ # Sub-meters for DER at triplex (secondary) nodes — mirrors Java AppendSubMeter
190
+ for suffix, present in (("_pvmtr", has_pv), ("_stmtr", has_storage), ("_dgmtr", has_sync)):
191
+ if not present:
192
+ continue
193
+ sub = glm_schema.TriplexMeter()
194
+ sub.name = node_name + suffix
195
+ sub.parent = node_name
196
+ sub.phases = glm_node["phases"]
197
+ sub.nominal_voltage = glm_node["nominal_voltage"]
198
+ glm_model.add_to_graph(sub)
199
+
200
+ else:
201
+ if has_storage or has_sync:
202
+ glm_node["bustype"] = "SWING_PQ"
203
+ glm_node["outside_comments"] = [f"Name:{node.name}"]
204
+
205
+ # Create Node dataclass instance
206
+ node_obj = glm_schema.Node()
207
+ for key, value in glm_node.items():
208
+ setattr(node_obj, key, value)
209
+ glm_model.add_to_graph(node_obj)
210
+
211
+ # Sub-meters for DER at primary nodes — mirrors Java AppendSubMeter
212
+ for suffix, present in (("_pvmtr", has_pv), ("_stmtr", has_storage), ("_dgmtr", has_sync)):
213
+ if not present:
214
+ continue
215
+ sub = glm_schema.Meter()
216
+ sub.name = node_name + suffix
217
+ sub.parent = node_name
218
+ sub.phases = glm_node["phases"]
219
+ sub.nominal_voltage = glm_node["nominal_voltage"]
220
+ glm_model.add_to_graph(sub)