aiocomfoconnect 0.4.4__tar.gz → 0.4.5__tar.gz
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- {aiocomfoconnect-0.4.4 → aiocomfoconnect-0.4.5}/PKG-INFO +4 -3
- {aiocomfoconnect-0.4.4 → aiocomfoconnect-0.4.5}/README.md +3 -2
- {aiocomfoconnect-0.4.4 → aiocomfoconnect-0.4.5}/aiocomfoconnect/__main__.py +4 -6
- {aiocomfoconnect-0.4.4 → aiocomfoconnect-0.4.5}/aiocomfoconnect/bridge.py +35 -30
- {aiocomfoconnect-0.4.4 → aiocomfoconnect-0.4.5}/aiocomfoconnect/comfoconnect.py +26 -15
- {aiocomfoconnect-0.4.4 → aiocomfoconnect-0.4.5}/aiocomfoconnect/const.py +10 -10
- {aiocomfoconnect-0.4.4 → aiocomfoconnect-0.4.5}/aiocomfoconnect/discovery.py +0 -1
- {aiocomfoconnect-0.4.4 → aiocomfoconnect-0.4.5}/aiocomfoconnect/properties.py +1 -0
- {aiocomfoconnect-0.4.4 → aiocomfoconnect-0.4.5}/pyproject.toml +1 -1
- {aiocomfoconnect-0.4.4 → aiocomfoconnect-0.4.5}/LICENSE +0 -0
- {aiocomfoconnect-0.4.4 → aiocomfoconnect-0.4.5}/aiocomfoconnect/__init__.py +0 -0
- {aiocomfoconnect-0.4.4 → aiocomfoconnect-0.4.5}/aiocomfoconnect/exceptions.py +0 -0
- {aiocomfoconnect-0.4.4 → aiocomfoconnect-0.4.5}/aiocomfoconnect/protobuf/nanopb_pb2.py +0 -0
- {aiocomfoconnect-0.4.4 → aiocomfoconnect-0.4.5}/aiocomfoconnect/protobuf/zehnder_pb2.py +0 -0
- {aiocomfoconnect-0.4.4 → aiocomfoconnect-0.4.5}/aiocomfoconnect/sensors.py +0 -0
- {aiocomfoconnect-0.4.4 → aiocomfoconnect-0.4.5}/aiocomfoconnect/util.py +0 -0
|
@@ -1,6 +1,6 @@
|
|
|
1
1
|
Metadata-Version: 2.4
|
|
2
2
|
Name: aiocomfoconnect
|
|
3
|
-
Version: 0.4.
|
|
3
|
+
Version: 0.4.5
|
|
4
4
|
Summary: aiocomfoconnect is an asyncio Python 3 library for communicating with a Zehnder ComfoAir Q350/450/600 ventilation system
|
|
5
5
|
License: MIT
|
|
6
6
|
License-File: LICENSE
|
|
@@ -65,10 +65,12 @@ $ python -m aiocomfoconnect set-property --host 192.168.1.213 30 1 4 6 120 # Se
|
|
|
65
65
|
|
|
66
66
|
- `async connect()`: Connect to the bridge. The connection is kept: when it is lost, it reconnects, and when nothing was sent or received for `heartbeat_interval` seconds (30 by default, `None` disables it), it asks the bridge for its time. That keeps the bridge from closing the connection (it does so after about 90 seconds in which the client sent nothing, even while it pushes sensor values), and detects a bridge that stopped answering.
|
|
67
67
|
- `connection_state_callback`: Pass it to `ComfoConnect()` to be called with a `ConnectionState` when the state of the session changes.
|
|
68
|
+
- `node_callback`: Pass it to `ComfoConnect()` to be called with a `Node` every time the bridge announces one: at the start of every session (already while `connect()` runs, and often more than once), and when a node joins or goes offline (`node.is_offline`).
|
|
68
69
|
- `async disconnect()`: Disconnect from the bridge.
|
|
69
70
|
- `async register_sensor(sensor)`: Register a sensor.
|
|
70
71
|
- `async deregister_sensor(sensor)`: Deregister a sensor.
|
|
71
72
|
- `sensor_values`: The latest value of every registered sensor, by sensor id, converted like for the sensor callback (`None` until the bridge sent one).
|
|
73
|
+
- `bridge_node`: The `Node` of the bridge itself on the ComfoNet bus: product id 222 for a ComfoConnect Pro, 5 for a ComfoConnect LAN C, or 9 for the WiFi connection module of a ComfoAir Flex. It is `None` when the bridge didn't announce it (yet): it does so a little after the ventilation unit.
|
|
72
74
|
- `async get_mode()`: Get the ventilation mode.
|
|
73
75
|
- `async set_mode(mode)`: Set the ventilation mode. (auto / manual) Selecting `auto` also cancels the temporary fan-speed override and returns control to the unit's schedule.
|
|
74
76
|
- `async get_comfocool_mode()`: Get Comfocool mode
|
|
@@ -87,13 +89,12 @@ $ python -m aiocomfoconnect set-property --host 192.168.1.213 30 1 4 6 120 # Se
|
|
|
87
89
|
- `async set_temperature_profile(profile)`: Set the temperature profile. (warm / normal / cool)
|
|
88
90
|
- `async get_property(prop, node_id=None)`: Get the value of a property, e.g. `PROPERTY_RMOT_HEATING_THRESHOLD`. It is read from the node the property lives on: the ventilation unit, or the ComfoClime for the `PROPERTY_CLIME_*` properties. Pass `node_id` to read it from another node. A `NodeNotFoundException` is raised when the node isn't on the bus.
|
|
89
91
|
- `async get_properties(props, node_id=None)`: Get several properties of one node in one request, converted like `get_property`, e.g. `await comfoconnect.get_properties([PROPERTY_MODEL, PROPERTY_SERIAL_NUMBER])`.
|
|
90
|
-
- `async get_node_info(node_id=None)`: Get the `NodeInfo` (name, model, article number, serial number, firmware version and
|
|
92
|
+
- `async get_node_info(node_id=None)`: Get the `NodeInfo` (name, model, article number, serial number, firmware version, hardware version and product variant) of a node, the ventilation unit by default, in one request. A property that the node doesn't have, like the model of the bridge, is `None`.
|
|
91
93
|
- `async set_property(prop, value, node_id=None)`: Set a property, on the same node as `get_property`.
|
|
92
94
|
- The airflow in m³/h of each fan speed is a property: `PROPERTY_FLOW_AWAY`, `PROPERTY_FLOW_LOW`, `PROPERTY_FLOW_MEDIUM` and `PROPERTY_FLOW_HIGH`, e.g. `await comfoconnect.set_property(PROPERTY_FLOW_LOW, 120)`.
|
|
93
95
|
- Properties that are an enum, like `PROPERTY_SENSOR_VENTILATION_TEMP_PASSIVE`, `PROPERTY_SENSOR_VENTILATION_HUMIDITY_COMFORT` and `PROPERTY_SENSOR_VENTILATION_HUMIDITY_PROTECTION` (off / auto / on), `PROPERTY_TEMPERATURE_PROFILE_MODE` (adaptive / fixed), `PROPERTY_CLIME_SEASON` and `PROPERTY_CLIME_TEMPERATURE_PROFILE`, have `options`: `get_property` returns the option and `set_property` takes it. `get_property_constraints` still uses the raw values.
|
|
94
96
|
- Temperatures in tenths of a degree, like `PROPERTY_RMOT_HEATING_THRESHOLD`, `PROPERTY_PROFILE_TEMPERATURE_NORMAL` and the ComfoClime temperatures, have `scale=0.1`: `get_property` and `get_property_constraints` return °C (215 becomes 21.5) and `set_property` takes °C.
|
|
95
97
|
- `async get_property_constraints(prop, node_id=None)`: Get the value of a numeric property, together with the range and step size the unit accepts.
|
|
96
|
-
- `bridge_type`: The type of the bridge (`GatewayType.LANC`, `SEASON` or `PRO`). Discovery reports it, and a ComfoConnect Pro is also recognised once a session has started.
|
|
97
98
|
|
|
98
99
|
### Low-level API
|
|
99
100
|
|
|
@@ -47,10 +47,12 @@ $ python -m aiocomfoconnect set-property --host 192.168.1.213 30 1 4 6 120 # Se
|
|
|
47
47
|
|
|
48
48
|
- `async connect()`: Connect to the bridge. The connection is kept: when it is lost, it reconnects, and when nothing was sent or received for `heartbeat_interval` seconds (30 by default, `None` disables it), it asks the bridge for its time. That keeps the bridge from closing the connection (it does so after about 90 seconds in which the client sent nothing, even while it pushes sensor values), and detects a bridge that stopped answering.
|
|
49
49
|
- `connection_state_callback`: Pass it to `ComfoConnect()` to be called with a `ConnectionState` when the state of the session changes.
|
|
50
|
+
- `node_callback`: Pass it to `ComfoConnect()` to be called with a `Node` every time the bridge announces one: at the start of every session (already while `connect()` runs, and often more than once), and when a node joins or goes offline (`node.is_offline`).
|
|
50
51
|
- `async disconnect()`: Disconnect from the bridge.
|
|
51
52
|
- `async register_sensor(sensor)`: Register a sensor.
|
|
52
53
|
- `async deregister_sensor(sensor)`: Deregister a sensor.
|
|
53
54
|
- `sensor_values`: The latest value of every registered sensor, by sensor id, converted like for the sensor callback (`None` until the bridge sent one).
|
|
55
|
+
- `bridge_node`: The `Node` of the bridge itself on the ComfoNet bus: product id 222 for a ComfoConnect Pro, 5 for a ComfoConnect LAN C, or 9 for the WiFi connection module of a ComfoAir Flex. It is `None` when the bridge didn't announce it (yet): it does so a little after the ventilation unit.
|
|
54
56
|
- `async get_mode()`: Get the ventilation mode.
|
|
55
57
|
- `async set_mode(mode)`: Set the ventilation mode. (auto / manual) Selecting `auto` also cancels the temporary fan-speed override and returns control to the unit's schedule.
|
|
56
58
|
- `async get_comfocool_mode()`: Get Comfocool mode
|
|
@@ -69,13 +71,12 @@ $ python -m aiocomfoconnect set-property --host 192.168.1.213 30 1 4 6 120 # Se
|
|
|
69
71
|
- `async set_temperature_profile(profile)`: Set the temperature profile. (warm / normal / cool)
|
|
70
72
|
- `async get_property(prop, node_id=None)`: Get the value of a property, e.g. `PROPERTY_RMOT_HEATING_THRESHOLD`. It is read from the node the property lives on: the ventilation unit, or the ComfoClime for the `PROPERTY_CLIME_*` properties. Pass `node_id` to read it from another node. A `NodeNotFoundException` is raised when the node isn't on the bus.
|
|
71
73
|
- `async get_properties(props, node_id=None)`: Get several properties of one node in one request, converted like `get_property`, e.g. `await comfoconnect.get_properties([PROPERTY_MODEL, PROPERTY_SERIAL_NUMBER])`.
|
|
72
|
-
- `async get_node_info(node_id=None)`: Get the `NodeInfo` (name, model, article number, serial number, firmware version and
|
|
74
|
+
- `async get_node_info(node_id=None)`: Get the `NodeInfo` (name, model, article number, serial number, firmware version, hardware version and product variant) of a node, the ventilation unit by default, in one request. A property that the node doesn't have, like the model of the bridge, is `None`.
|
|
73
75
|
- `async set_property(prop, value, node_id=None)`: Set a property, on the same node as `get_property`.
|
|
74
76
|
- The airflow in m³/h of each fan speed is a property: `PROPERTY_FLOW_AWAY`, `PROPERTY_FLOW_LOW`, `PROPERTY_FLOW_MEDIUM` and `PROPERTY_FLOW_HIGH`, e.g. `await comfoconnect.set_property(PROPERTY_FLOW_LOW, 120)`.
|
|
75
77
|
- Properties that are an enum, like `PROPERTY_SENSOR_VENTILATION_TEMP_PASSIVE`, `PROPERTY_SENSOR_VENTILATION_HUMIDITY_COMFORT` and `PROPERTY_SENSOR_VENTILATION_HUMIDITY_PROTECTION` (off / auto / on), `PROPERTY_TEMPERATURE_PROFILE_MODE` (adaptive / fixed), `PROPERTY_CLIME_SEASON` and `PROPERTY_CLIME_TEMPERATURE_PROFILE`, have `options`: `get_property` returns the option and `set_property` takes it. `get_property_constraints` still uses the raw values.
|
|
76
78
|
- Temperatures in tenths of a degree, like `PROPERTY_RMOT_HEATING_THRESHOLD`, `PROPERTY_PROFILE_TEMPERATURE_NORMAL` and the ComfoClime temperatures, have `scale=0.1`: `get_property` and `get_property_constraints` return °C (215 becomes 21.5) and `set_property` takes °C.
|
|
77
79
|
- `async get_property_constraints(prop, node_id=None)`: Get the value of a numeric property, together with the range and step size the unit accepts.
|
|
78
|
-
- `bridge_type`: The type of the bridge (`GatewayType.LANC`, `SEASON` or `PRO`). Discovery reports it, and a ComfoConnect Pro is also recognised once a session has started.
|
|
79
80
|
|
|
80
81
|
### Low-level API
|
|
81
82
|
|
|
@@ -43,7 +43,7 @@ async def connected(args, *, connect: bool = True, **kwargs) -> AsyncIterator[Co
|
|
|
43
43
|
if not bridges:
|
|
44
44
|
raise BridgeNotFoundException("No bridge found")
|
|
45
45
|
|
|
46
|
-
comfoconnect = ComfoConnect(bridges[0].host, bridges[0].uuid,
|
|
46
|
+
comfoconnect = ComfoConnect(bridges[0].host, bridges[0].uuid, **kwargs)
|
|
47
47
|
try:
|
|
48
48
|
if connect:
|
|
49
49
|
try:
|
|
@@ -82,14 +82,11 @@ async def run_register(args):
|
|
|
82
82
|
"""Register an app on the bridge."""
|
|
83
83
|
async with connected(args, connect=False) as comfoconnect:
|
|
84
84
|
try:
|
|
85
|
-
|
|
85
|
+
await comfoconnect.register(args.uuid, args.name, args.pin)
|
|
86
86
|
except ComfoConnectNotAllowed as exc:
|
|
87
87
|
raise CliError("Registration failed. Please check the PIN.") from exc
|
|
88
88
|
|
|
89
|
-
|
|
90
|
-
print(f"UUID {args.uuid} is now registered.")
|
|
91
|
-
else:
|
|
92
|
-
print(f"UUID {args.uuid} is already registered.")
|
|
89
|
+
print(f"UUID {args.uuid} is registered.")
|
|
93
90
|
|
|
94
91
|
await print_registered_apps(comfoconnect)
|
|
95
92
|
|
|
@@ -208,6 +205,7 @@ async def run_list_nodes(args):
|
|
|
208
205
|
fields = {
|
|
209
206
|
"name": info.name,
|
|
210
207
|
"model": info.model,
|
|
208
|
+
"product variant": info.product_variant,
|
|
211
209
|
"firmware": info.firmware,
|
|
212
210
|
"hardware version": info.hardware_version,
|
|
213
211
|
"serial number": info.serial_number,
|
|
@@ -14,7 +14,7 @@ from typing import Awaitable, Callable, Dict, Iterator, Optional
|
|
|
14
14
|
from google.protobuf.message import DecodeError
|
|
15
15
|
from google.protobuf.message import Message as ProtobufMessage
|
|
16
16
|
|
|
17
|
-
from .const import NUMERIC_PROPERTY_TYPES, VENTILATION_UNIT_PRODUCT_IDS,
|
|
17
|
+
from .const import BRIDGE_PRODUCT_IDS, NUMERIC_PROPERTY_TYPES, VENTILATION_UNIT_PRODUCT_IDS, ProductId
|
|
18
18
|
from .exceptions import (
|
|
19
19
|
AioComfoConnectNotConnected,
|
|
20
20
|
AioComfoConnectNotReachable,
|
|
@@ -81,6 +81,11 @@ class Node:
|
|
|
81
81
|
"""Returns True if this node is the ventilation unit that handles RMI commands."""
|
|
82
82
|
return self.product_id in VENTILATION_UNIT_PRODUCT_IDS
|
|
83
83
|
|
|
84
|
+
@property
|
|
85
|
+
def is_bridge(self) -> bool:
|
|
86
|
+
"""Returns True if this node is a bridge, like the ComfoConnect LAN C."""
|
|
87
|
+
return self.product_id in BRIDGE_PRODUCT_IDS
|
|
88
|
+
|
|
84
89
|
@property
|
|
85
90
|
def is_comfoclime(self) -> bool:
|
|
86
91
|
"""Returns True if this node is a ComfoClime heat pump module."""
|
|
@@ -96,12 +101,9 @@ class Bridge:
|
|
|
96
101
|
self,
|
|
97
102
|
host: str,
|
|
98
103
|
uuid: str,
|
|
99
|
-
bridge_type: int = 0,
|
|
100
104
|
):
|
|
101
105
|
self.host: str = host
|
|
102
106
|
self.uuid: str = uuid
|
|
103
|
-
# One of GatewayType. Discovery reports it, and a ComfoConnect Pro also identifies itself when a session starts.
|
|
104
|
-
self.bridge_type: int = bridge_type
|
|
105
107
|
self._local_uuid: Optional[str] = None
|
|
106
108
|
|
|
107
109
|
self._reader: Optional[StreamReader] = None
|
|
@@ -113,6 +115,7 @@ class Bridge:
|
|
|
113
115
|
|
|
114
116
|
self._nodes: Dict[int, Node] = {}
|
|
115
117
|
self._ventilation_node_found: Optional[asyncio.Event] = None
|
|
118
|
+
self.__node_callback_fn: Optional[Callable[[Node], None]] = None
|
|
116
119
|
|
|
117
120
|
self.__sensor_callback_fn: Optional[Callable[[int, int], None]] = None
|
|
118
121
|
self._sensor_pdo_types: Dict[int, int] = {}
|
|
@@ -134,31 +137,27 @@ class Bridge:
|
|
|
134
137
|
"""Set a callback to be called when an alarm is received."""
|
|
135
138
|
self.__alarm_callback_fn = callback
|
|
136
139
|
|
|
140
|
+
def set_node_callback(self, callback: Optional[Callable[[Node], None]]):
|
|
141
|
+
"""Set a callback to be called every time the bridge announces a node, also when it goes offline (see Node.is_offline).
|
|
142
|
+
|
|
143
|
+
The bridge announces the nodes when a session starts, often more than once, so a node can be announced again.
|
|
144
|
+
"""
|
|
145
|
+
self.__node_callback_fn = callback
|
|
146
|
+
|
|
137
147
|
async def connect(self, uuid: str):
|
|
138
148
|
"""Connect to the bridge and start reading messages."""
|
|
139
149
|
await self._open_connection(uuid)
|
|
140
150
|
|
|
141
|
-
async def register(self, uuid: str, name: str, pin: int) ->
|
|
151
|
+
async def register(self, uuid: str, name: str, pin: int) -> None:
|
|
142
152
|
"""Register this app on the bridge and start a session.
|
|
143
153
|
|
|
144
|
-
|
|
145
|
-
|
|
146
|
-
|
|
147
|
-
the Pro issues when the app is not yet registered.
|
|
148
|
-
|
|
149
|
-
Returns True if the app was newly registered, False if it was already registered.
|
|
154
|
+
Like the official app, this registers directly: a bridge accepts an app that is registered already, as long as
|
|
155
|
+
the PIN is right. We don't start a session first to find out, since a ComfoConnect Pro doesn't answer that for an
|
|
156
|
+
app that isn't registered. ComfoConnectNotAllowed is raised for a wrong PIN.
|
|
150
157
|
"""
|
|
151
158
|
await self._open_connection(uuid)
|
|
152
|
-
if self.bridge_type != GatewayType.PRO:
|
|
153
|
-
# LAN C: check whether we are already registered by starting a session.
|
|
154
|
-
try:
|
|
155
|
-
await self.cmd_start_session()
|
|
156
|
-
return False # Already registered; session is now active.
|
|
157
|
-
except ComfoConnectNotAllowed:
|
|
158
|
-
pass # Not registered yet; fall through to register below.
|
|
159
159
|
await self.cmd_register_app(uuid, name, pin)
|
|
160
160
|
await self.cmd_start_session()
|
|
161
|
-
return True
|
|
162
161
|
|
|
163
162
|
async def _open_connection(self, uuid: str):
|
|
164
163
|
"""Open TCP connection to the bridge and start reading messages."""
|
|
@@ -266,13 +265,15 @@ class Bridge:
|
|
|
266
265
|
if node.is_offline:
|
|
267
266
|
_LOGGER.debug("Node %s went offline", node.node_id)
|
|
268
267
|
self._nodes.pop(node.node_id, None)
|
|
269
|
-
|
|
268
|
+
else:
|
|
269
|
+
_LOGGER.debug("Discovered node %s with product id %s in zone %s", node.node_id, node.product_id, node.zone_id)
|
|
270
|
+
self._nodes[node.node_id] = node
|
|
270
271
|
|
|
271
|
-
|
|
272
|
-
|
|
272
|
+
if node.is_ventilation_unit and self._ventilation_node_found is not None:
|
|
273
|
+
self._ventilation_node_found.set()
|
|
273
274
|
|
|
274
|
-
if
|
|
275
|
-
self.
|
|
275
|
+
if self.__node_callback_fn:
|
|
276
|
+
self.__node_callback_fn(node)
|
|
276
277
|
|
|
277
278
|
@property
|
|
278
279
|
def nodes(self) -> Dict[int, Node]:
|
|
@@ -285,6 +286,15 @@ class Bridge:
|
|
|
285
286
|
candidates = [node.node_id for node in self._nodes.values() if node.is_ventilation_unit]
|
|
286
287
|
return min(candidates) if candidates else None
|
|
287
288
|
|
|
289
|
+
@property
|
|
290
|
+
def bridge_node(self) -> Optional[Node]:
|
|
291
|
+
"""The node of the bridge itself, or None when the bridge hasn't announced it (yet).
|
|
292
|
+
|
|
293
|
+
A ComfoAir Flex with a ComfoConnect LAN C would have two, and then it's the LAN C (see BRIDGE_PRODUCT_IDS).
|
|
294
|
+
"""
|
|
295
|
+
candidates = [node for node in self._nodes.values() if node.is_bridge]
|
|
296
|
+
return min(candidates, key=lambda node: (BRIDGE_PRODUCT_IDS.index(node.product_id), node.node_id)) if candidates else None
|
|
297
|
+
|
|
288
298
|
@property
|
|
289
299
|
def comfoclime_node_id(self) -> Optional[int]:
|
|
290
300
|
"""The node id of the ComfoClime, or None when the bridge hasn't announced one."""
|
|
@@ -472,16 +482,11 @@ class Bridge:
|
|
|
472
482
|
"""Starts the session on the device by logging in and optionally disconnecting an already existing session."""
|
|
473
483
|
_LOGGER.debug("StartSessionRequest")
|
|
474
484
|
# pylint: disable=no-member
|
|
475
|
-
|
|
485
|
+
return await self._send(
|
|
476
486
|
zehnder_pb2.StartSessionRequest,
|
|
477
487
|
zehnder_pb2.GatewayOperation.StartSessionRequestType,
|
|
478
488
|
{"takeover": take_over},
|
|
479
489
|
)
|
|
480
|
-
# A ComfoConnect Pro sets the devicename of a successful session to "ccpro", a LAN C leaves it empty. This also
|
|
481
|
-
# tells us the type of a bridge that was connected to by IP address, without discovery.
|
|
482
|
-
if getattr(reply, "devicename", None) == "ccpro":
|
|
483
|
-
self.bridge_type = GatewayType.PRO
|
|
484
|
-
return reply
|
|
485
490
|
|
|
486
491
|
def cmd_close_session(self) -> Awaitable[Message]:
|
|
487
492
|
"""Stops the current session."""
|
|
@@ -10,7 +10,7 @@ from dataclasses import dataclass
|
|
|
10
10
|
from typing import Any, Awaitable, Callable, Dict, List, Literal, Optional
|
|
11
11
|
|
|
12
12
|
from aiocomfoconnect import Bridge
|
|
13
|
-
from aiocomfoconnect.bridge import Message
|
|
13
|
+
from aiocomfoconnect.bridge import Message, Node
|
|
14
14
|
from aiocomfoconnect.const import (
|
|
15
15
|
ERRORS,
|
|
16
16
|
ERRORS_140,
|
|
@@ -54,6 +54,7 @@ from aiocomfoconnect.properties import (
|
|
|
54
54
|
PROPERTY_HARDWARE_VERSION,
|
|
55
55
|
PROPERTY_MODEL,
|
|
56
56
|
PROPERTY_NAME,
|
|
57
|
+
PROPERTY_PRODUCT_VARIANT,
|
|
57
58
|
PROPERTY_SERIAL_NUMBER,
|
|
58
59
|
Property,
|
|
59
60
|
PropertyConstraints,
|
|
@@ -120,6 +121,7 @@ class NodeInfo:
|
|
|
120
121
|
serial_number: Optional[str]
|
|
121
122
|
firmware: Optional[str]
|
|
122
123
|
hardware_version: Optional[int]
|
|
124
|
+
product_variant: Optional[int] # Which model of the product, e.g. 3 is a Q600 for a ComfoAir Q (see PROTOCOL-RMI.md).
|
|
123
125
|
|
|
124
126
|
|
|
125
127
|
@dataclass
|
|
@@ -144,9 +146,9 @@ class ComfoConnect(Bridge):
|
|
|
144
146
|
alarm_callback=None,
|
|
145
147
|
sensor_delay=5,
|
|
146
148
|
connect_timeout=30,
|
|
147
|
-
bridge_type: int = 0,
|
|
148
149
|
heartbeat_interval: Optional[float] = HEARTBEAT_INTERVAL,
|
|
149
150
|
connection_state_callback: Optional[Callable[[str], None]] = None,
|
|
151
|
+
node_callback: Optional[Callable[[Node], None]] = None,
|
|
150
152
|
):
|
|
151
153
|
"""Initialize the ComfoConnect class.
|
|
152
154
|
|
|
@@ -155,11 +157,15 @@ class ComfoConnect(Bridge):
|
|
|
155
157
|
that stopped answering without closing the connection. None disables it.
|
|
156
158
|
|
|
157
159
|
The connection_state_callback is called with a ConnectionState when the state of the session changes.
|
|
160
|
+
|
|
161
|
+
The node_callback is called with a Node every time the bridge announces one: at the start of every session, already
|
|
162
|
+
while connect() runs and often more than once, and when a node joins or goes offline (see Node.is_offline).
|
|
158
163
|
"""
|
|
159
|
-
super().__init__(host, uuid
|
|
164
|
+
super().__init__(host, uuid)
|
|
160
165
|
|
|
161
166
|
self.set_sensor_callback(self._sensor_callback) # Set the callback to our _sensor_callback method, so we can proces the callbacks.
|
|
162
167
|
self.set_alarm_callback(self._alarm_callback) # Set the callback to our _alarm_callback method, so we can proces the callbacks.
|
|
168
|
+
self.set_node_callback(node_callback)
|
|
163
169
|
self.sensor_delay = sensor_delay
|
|
164
170
|
self.connect_timeout = connect_timeout
|
|
165
171
|
self.heartbeat_interval = heartbeat_interval
|
|
@@ -481,31 +487,36 @@ class ComfoConnect(Bridge):
|
|
|
481
487
|
return values
|
|
482
488
|
|
|
483
489
|
async def get_node_info(self, node_id: Optional[int] = None) -> NodeInfo:
|
|
484
|
-
"""Get the NodeInfo of a node (the ventilation unit by default)
|
|
490
|
+
"""Get the NodeInfo of a node (the ventilation unit by default). A property that the node doesn't have is None.
|
|
485
491
|
|
|
486
|
-
|
|
492
|
+
The properties are read one by one: a node fails a request for several as a whole when it lacks one of them, and
|
|
493
|
+
a ComfoConnect Pro answers it with fewer values than asked. Raises ComfoConnectRmiError when none of the
|
|
494
|
+
properties can be read, e.g. for a node that doesn't exist.
|
|
487
495
|
"""
|
|
488
|
-
props = [PROPERTY_NAME, PROPERTY_MODEL, PROPERTY_ARTICLE, PROPERTY_SERIAL_NUMBER, PROPERTY_FIRMWARE_VERSION, PROPERTY_HARDWARE_VERSION]
|
|
489
|
-
|
|
490
|
-
return NodeInfo(*await self.get_properties(props, node_id))
|
|
491
|
-
except ComfoConnectRmiError as exc:
|
|
492
|
-
error = exc
|
|
496
|
+
props = [PROPERTY_NAME, PROPERTY_MODEL, PROPERTY_ARTICLE, PROPERTY_SERIAL_NUMBER, PROPERTY_FIRMWARE_VERSION, PROPERTY_HARDWARE_VERSION, PROPERTY_PRODUCT_VARIANT]
|
|
497
|
+
errors: List[ComfoConnectRmiError] = []
|
|
493
498
|
|
|
494
|
-
# A request fails as a whole when the node lacks one of the properties, so read them one by one.
|
|
495
499
|
async def get_or_none(prop: Property) -> Any:
|
|
496
500
|
try:
|
|
497
501
|
return await self.get_property(prop, node_id)
|
|
498
|
-
except ComfoConnectRmiError:
|
|
502
|
+
except ComfoConnectRmiError as exc:
|
|
503
|
+
errors.append(exc)
|
|
499
504
|
return None
|
|
500
505
|
|
|
501
506
|
values = [await get_or_none(prop) for prop in props]
|
|
502
|
-
if
|
|
503
|
-
raise
|
|
507
|
+
if len(errors) == len(props):
|
|
508
|
+
raise errors[0]
|
|
504
509
|
return NodeInfo(*values)
|
|
505
510
|
|
|
506
511
|
async def get_single_property(self, unit: int, subunit: int, property_id: int, property_type: int = None, node_id: Optional[int] = None) -> Any:
|
|
507
|
-
"""Get a property and convert to the right type.
|
|
512
|
+
"""Get a property and convert to the right type.
|
|
513
|
+
|
|
514
|
+
Raises ComfoConnectRmiError when the node doesn't have the property: it answers with an RMI error, or, like the
|
|
515
|
+
node of a ComfoConnect Pro, with an empty message.
|
|
516
|
+
"""
|
|
508
517
|
result = await self.cmd_rmi_request(bytes([0x01, unit, subunit, 0x10, property_id]), node_id=node_id)
|
|
518
|
+
if not result.message:
|
|
519
|
+
raise ComfoConnectRmiError(f"The node sent no value for property {property_id}")
|
|
509
520
|
return _decode_value(property_type, result.message)
|
|
510
521
|
|
|
511
522
|
async def get_property_constraints(self, prop: Property, node_id: Optional[int] = None) -> PropertyConstraints:
|
|
@@ -30,16 +30,12 @@ class ProductId:
|
|
|
30
30
|
# nodes on the bus (gateway, connection board, sensors, ...) will reply with RMI_ERROR.
|
|
31
31
|
VENTILATION_UNIT_PRODUCT_IDS = (ProductId.COMFOAIRQ, ProductId.COMFOAIRFLEX)
|
|
32
32
|
|
|
33
|
-
|
|
34
|
-
#
|
|
35
|
-
|
|
36
|
-
"""Defines the type of a bridge, with the values of the GatewayType in the discovery response."""
|
|
37
|
-
|
|
38
|
-
LANC = 0 # ComfoConnect LAN C
|
|
39
|
-
SEASON = 1 # The built-in WiFi module of a ComfoAir Flex
|
|
40
|
-
PRO = 2 # ComfoConnect Pro
|
|
33
|
+
# The product ids of the bridge itself on the bus, in order of preference: a ComfoConnect Pro, a ComfoConnect LAN C,
|
|
34
|
+
# and the WiFi connection module built into a ComfoAir Flex. A Flex with a LAN C would have both of the last two.
|
|
35
|
+
BRIDGE_PRODUCT_IDS = (ProductId.COMFOCONNECTPRO, ProductId.ZEHNDERGATEWAY, ProductId.COMFOAIRFLEXCONNECTIONBOARD)
|
|
41
36
|
|
|
42
37
|
|
|
38
|
+
# PDO Types
|
|
43
39
|
class ConnectionState:
|
|
44
40
|
"""The state of the session with the bridge, as reported to the connection state callback."""
|
|
45
41
|
|
|
@@ -55,12 +51,14 @@ class PdoType:
|
|
|
55
51
|
TYPE_CN_UINT8 = 0x01
|
|
56
52
|
TYPE_CN_UINT16 = 0x02
|
|
57
53
|
TYPE_CN_UINT32 = 0x03
|
|
54
|
+
TYPE_CN_UINT64 = 0x04
|
|
58
55
|
TYPE_CN_INT8 = 0x05
|
|
59
56
|
TYPE_CN_INT16 = 0x06
|
|
57
|
+
TYPE_CN_INT32 = 0x07
|
|
60
58
|
TYPE_CN_INT64 = 0x08
|
|
61
59
|
TYPE_CN_STRING = 0x09
|
|
62
|
-
TYPE_CN_TIME =
|
|
63
|
-
TYPE_CN_VERSION =
|
|
60
|
+
TYPE_CN_TIME = 0x0A
|
|
61
|
+
TYPE_CN_VERSION = 0x0B
|
|
64
62
|
|
|
65
63
|
|
|
66
64
|
# The size in bytes and the signedness of the numeric PDO and property types.
|
|
@@ -68,8 +66,10 @@ NUMERIC_PROPERTY_TYPES = {
|
|
|
68
66
|
PdoType.TYPE_CN_UINT8: (1, False),
|
|
69
67
|
PdoType.TYPE_CN_UINT16: (2, False),
|
|
70
68
|
PdoType.TYPE_CN_UINT32: (4, False),
|
|
69
|
+
PdoType.TYPE_CN_UINT64: (8, False),
|
|
71
70
|
PdoType.TYPE_CN_INT8: (1, True),
|
|
72
71
|
PdoType.TYPE_CN_INT16: (2, True),
|
|
72
|
+
PdoType.TYPE_CN_INT32: (4, True),
|
|
73
73
|
PdoType.TYPE_CN_INT64: (8, True),
|
|
74
74
|
}
|
|
75
75
|
|
|
@@ -49,6 +49,7 @@ class PropertyConstraints:
|
|
|
49
49
|
step: int | float
|
|
50
50
|
|
|
51
51
|
|
|
52
|
+
PROPERTY_PRODUCT_VARIANT = Property(UNIT_NODE, 0x01, 0x03, PdoType.TYPE_CN_UINT8) # E.g. 1=Q350, 2=Q450, 3=Q600 on a ComfoAir Q.
|
|
52
53
|
PROPERTY_SERIAL_NUMBER = Property(UNIT_NODE, 0x01, 0x04, PdoType.TYPE_CN_STRING)
|
|
53
54
|
PROPERTY_HARDWARE_VERSION = Property(UNIT_NODE, 0x01, 0x05, PdoType.TYPE_CN_UINT8)
|
|
54
55
|
PROPERTY_FIRMWARE_VERSION = Property(UNIT_NODE, 0x01, 0x06, PdoType.TYPE_CN_VERSION) # A UINT32, decoded with version_decode().
|
|
@@ -1,6 +1,6 @@
|
|
|
1
1
|
[tool.poetry]
|
|
2
2
|
name = "aiocomfoconnect"
|
|
3
|
-
version = "0.4.
|
|
3
|
+
version = "0.4.5"
|
|
4
4
|
description = "aiocomfoconnect is an asyncio Python 3 library for communicating with a Zehnder ComfoAir Q350/450/600 ventilation system"
|
|
5
5
|
authors = ["Michaël Arnauts <michael.arnauts@gmail.com>"]
|
|
6
6
|
license = "MIT"
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|