aiocomfoconnect 0.4.4__tar.gz → 0.4.5__tar.gz

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
@@ -1,6 +1,6 @@
1
1
  Metadata-Version: 2.4
2
2
  Name: aiocomfoconnect
3
- Version: 0.4.4
3
+ Version: 0.4.5
4
4
  Summary: aiocomfoconnect is an asyncio Python 3 library for communicating with a Zehnder ComfoAir Q350/450/600 ventilation system
5
5
  License: MIT
6
6
  License-File: LICENSE
@@ -65,10 +65,12 @@ $ python -m aiocomfoconnect set-property --host 192.168.1.213 30 1 4 6 120 # Se
65
65
 
66
66
  - `async connect()`: Connect to the bridge. The connection is kept: when it is lost, it reconnects, and when nothing was sent or received for `heartbeat_interval` seconds (30 by default, `None` disables it), it asks the bridge for its time. That keeps the bridge from closing the connection (it does so after about 90 seconds in which the client sent nothing, even while it pushes sensor values), and detects a bridge that stopped answering.
67
67
  - `connection_state_callback`: Pass it to `ComfoConnect()` to be called with a `ConnectionState` when the state of the session changes.
68
+ - `node_callback`: Pass it to `ComfoConnect()` to be called with a `Node` every time the bridge announces one: at the start of every session (already while `connect()` runs, and often more than once), and when a node joins or goes offline (`node.is_offline`).
68
69
  - `async disconnect()`: Disconnect from the bridge.
69
70
  - `async register_sensor(sensor)`: Register a sensor.
70
71
  - `async deregister_sensor(sensor)`: Deregister a sensor.
71
72
  - `sensor_values`: The latest value of every registered sensor, by sensor id, converted like for the sensor callback (`None` until the bridge sent one).
73
+ - `bridge_node`: The `Node` of the bridge itself on the ComfoNet bus: product id 222 for a ComfoConnect Pro, 5 for a ComfoConnect LAN C, or 9 for the WiFi connection module of a ComfoAir Flex. It is `None` when the bridge didn't announce it (yet): it does so a little after the ventilation unit.
72
74
  - `async get_mode()`: Get the ventilation mode.
73
75
  - `async set_mode(mode)`: Set the ventilation mode. (auto / manual) Selecting `auto` also cancels the temporary fan-speed override and returns control to the unit's schedule.
74
76
  - `async get_comfocool_mode()`: Get Comfocool mode
@@ -87,13 +89,12 @@ $ python -m aiocomfoconnect set-property --host 192.168.1.213 30 1 4 6 120 # Se
87
89
  - `async set_temperature_profile(profile)`: Set the temperature profile. (warm / normal / cool)
88
90
  - `async get_property(prop, node_id=None)`: Get the value of a property, e.g. `PROPERTY_RMOT_HEATING_THRESHOLD`. It is read from the node the property lives on: the ventilation unit, or the ComfoClime for the `PROPERTY_CLIME_*` properties. Pass `node_id` to read it from another node. A `NodeNotFoundException` is raised when the node isn't on the bus.
89
91
  - `async get_properties(props, node_id=None)`: Get several properties of one node in one request, converted like `get_property`, e.g. `await comfoconnect.get_properties([PROPERTY_MODEL, PROPERTY_SERIAL_NUMBER])`.
90
- - `async get_node_info(node_id=None)`: Get the `NodeInfo` (name, model, article number, serial number, firmware version and hardware version) of a node, the ventilation unit by default, in one request. A property that the node doesn't have, like the model of the bridge, is `None`.
92
+ - `async get_node_info(node_id=None)`: Get the `NodeInfo` (name, model, article number, serial number, firmware version, hardware version and product variant) of a node, the ventilation unit by default, in one request. A property that the node doesn't have, like the model of the bridge, is `None`.
91
93
  - `async set_property(prop, value, node_id=None)`: Set a property, on the same node as `get_property`.
92
94
  - The airflow in m³/h of each fan speed is a property: `PROPERTY_FLOW_AWAY`, `PROPERTY_FLOW_LOW`, `PROPERTY_FLOW_MEDIUM` and `PROPERTY_FLOW_HIGH`, e.g. `await comfoconnect.set_property(PROPERTY_FLOW_LOW, 120)`.
93
95
  - Properties that are an enum, like `PROPERTY_SENSOR_VENTILATION_TEMP_PASSIVE`, `PROPERTY_SENSOR_VENTILATION_HUMIDITY_COMFORT` and `PROPERTY_SENSOR_VENTILATION_HUMIDITY_PROTECTION` (off / auto / on), `PROPERTY_TEMPERATURE_PROFILE_MODE` (adaptive / fixed), `PROPERTY_CLIME_SEASON` and `PROPERTY_CLIME_TEMPERATURE_PROFILE`, have `options`: `get_property` returns the option and `set_property` takes it. `get_property_constraints` still uses the raw values.
94
96
  - Temperatures in tenths of a degree, like `PROPERTY_RMOT_HEATING_THRESHOLD`, `PROPERTY_PROFILE_TEMPERATURE_NORMAL` and the ComfoClime temperatures, have `scale=0.1`: `get_property` and `get_property_constraints` return °C (215 becomes 21.5) and `set_property` takes °C.
95
97
  - `async get_property_constraints(prop, node_id=None)`: Get the value of a numeric property, together with the range and step size the unit accepts.
96
- - `bridge_type`: The type of the bridge (`GatewayType.LANC`, `SEASON` or `PRO`). Discovery reports it, and a ComfoConnect Pro is also recognised once a session has started.
97
98
 
98
99
  ### Low-level API
99
100
 
@@ -47,10 +47,12 @@ $ python -m aiocomfoconnect set-property --host 192.168.1.213 30 1 4 6 120 # Se
47
47
 
48
48
  - `async connect()`: Connect to the bridge. The connection is kept: when it is lost, it reconnects, and when nothing was sent or received for `heartbeat_interval` seconds (30 by default, `None` disables it), it asks the bridge for its time. That keeps the bridge from closing the connection (it does so after about 90 seconds in which the client sent nothing, even while it pushes sensor values), and detects a bridge that stopped answering.
49
49
  - `connection_state_callback`: Pass it to `ComfoConnect()` to be called with a `ConnectionState` when the state of the session changes.
50
+ - `node_callback`: Pass it to `ComfoConnect()` to be called with a `Node` every time the bridge announces one: at the start of every session (already while `connect()` runs, and often more than once), and when a node joins or goes offline (`node.is_offline`).
50
51
  - `async disconnect()`: Disconnect from the bridge.
51
52
  - `async register_sensor(sensor)`: Register a sensor.
52
53
  - `async deregister_sensor(sensor)`: Deregister a sensor.
53
54
  - `sensor_values`: The latest value of every registered sensor, by sensor id, converted like for the sensor callback (`None` until the bridge sent one).
55
+ - `bridge_node`: The `Node` of the bridge itself on the ComfoNet bus: product id 222 for a ComfoConnect Pro, 5 for a ComfoConnect LAN C, or 9 for the WiFi connection module of a ComfoAir Flex. It is `None` when the bridge didn't announce it (yet): it does so a little after the ventilation unit.
54
56
  - `async get_mode()`: Get the ventilation mode.
55
57
  - `async set_mode(mode)`: Set the ventilation mode. (auto / manual) Selecting `auto` also cancels the temporary fan-speed override and returns control to the unit's schedule.
56
58
  - `async get_comfocool_mode()`: Get Comfocool mode
@@ -69,13 +71,12 @@ $ python -m aiocomfoconnect set-property --host 192.168.1.213 30 1 4 6 120 # Se
69
71
  - `async set_temperature_profile(profile)`: Set the temperature profile. (warm / normal / cool)
70
72
  - `async get_property(prop, node_id=None)`: Get the value of a property, e.g. `PROPERTY_RMOT_HEATING_THRESHOLD`. It is read from the node the property lives on: the ventilation unit, or the ComfoClime for the `PROPERTY_CLIME_*` properties. Pass `node_id` to read it from another node. A `NodeNotFoundException` is raised when the node isn't on the bus.
71
73
  - `async get_properties(props, node_id=None)`: Get several properties of one node in one request, converted like `get_property`, e.g. `await comfoconnect.get_properties([PROPERTY_MODEL, PROPERTY_SERIAL_NUMBER])`.
72
- - `async get_node_info(node_id=None)`: Get the `NodeInfo` (name, model, article number, serial number, firmware version and hardware version) of a node, the ventilation unit by default, in one request. A property that the node doesn't have, like the model of the bridge, is `None`.
74
+ - `async get_node_info(node_id=None)`: Get the `NodeInfo` (name, model, article number, serial number, firmware version, hardware version and product variant) of a node, the ventilation unit by default, in one request. A property that the node doesn't have, like the model of the bridge, is `None`.
73
75
  - `async set_property(prop, value, node_id=None)`: Set a property, on the same node as `get_property`.
74
76
  - The airflow in m³/h of each fan speed is a property: `PROPERTY_FLOW_AWAY`, `PROPERTY_FLOW_LOW`, `PROPERTY_FLOW_MEDIUM` and `PROPERTY_FLOW_HIGH`, e.g. `await comfoconnect.set_property(PROPERTY_FLOW_LOW, 120)`.
75
77
  - Properties that are an enum, like `PROPERTY_SENSOR_VENTILATION_TEMP_PASSIVE`, `PROPERTY_SENSOR_VENTILATION_HUMIDITY_COMFORT` and `PROPERTY_SENSOR_VENTILATION_HUMIDITY_PROTECTION` (off / auto / on), `PROPERTY_TEMPERATURE_PROFILE_MODE` (adaptive / fixed), `PROPERTY_CLIME_SEASON` and `PROPERTY_CLIME_TEMPERATURE_PROFILE`, have `options`: `get_property` returns the option and `set_property` takes it. `get_property_constraints` still uses the raw values.
76
78
  - Temperatures in tenths of a degree, like `PROPERTY_RMOT_HEATING_THRESHOLD`, `PROPERTY_PROFILE_TEMPERATURE_NORMAL` and the ComfoClime temperatures, have `scale=0.1`: `get_property` and `get_property_constraints` return °C (215 becomes 21.5) and `set_property` takes °C.
77
79
  - `async get_property_constraints(prop, node_id=None)`: Get the value of a numeric property, together with the range and step size the unit accepts.
78
- - `bridge_type`: The type of the bridge (`GatewayType.LANC`, `SEASON` or `PRO`). Discovery reports it, and a ComfoConnect Pro is also recognised once a session has started.
79
80
 
80
81
  ### Low-level API
81
82
 
@@ -43,7 +43,7 @@ async def connected(args, *, connect: bool = True, **kwargs) -> AsyncIterator[Co
43
43
  if not bridges:
44
44
  raise BridgeNotFoundException("No bridge found")
45
45
 
46
- comfoconnect = ComfoConnect(bridges[0].host, bridges[0].uuid, bridge_type=bridges[0].bridge_type, **kwargs)
46
+ comfoconnect = ComfoConnect(bridges[0].host, bridges[0].uuid, **kwargs)
47
47
  try:
48
48
  if connect:
49
49
  try:
@@ -82,14 +82,11 @@ async def run_register(args):
82
82
  """Register an app on the bridge."""
83
83
  async with connected(args, connect=False) as comfoconnect:
84
84
  try:
85
- registered = await comfoconnect.register(args.uuid, args.name, args.pin)
85
+ await comfoconnect.register(args.uuid, args.name, args.pin)
86
86
  except ComfoConnectNotAllowed as exc:
87
87
  raise CliError("Registration failed. Please check the PIN.") from exc
88
88
 
89
- if registered:
90
- print(f"UUID {args.uuid} is now registered.")
91
- else:
92
- print(f"UUID {args.uuid} is already registered.")
89
+ print(f"UUID {args.uuid} is registered.")
93
90
 
94
91
  await print_registered_apps(comfoconnect)
95
92
 
@@ -208,6 +205,7 @@ async def run_list_nodes(args):
208
205
  fields = {
209
206
  "name": info.name,
210
207
  "model": info.model,
208
+ "product variant": info.product_variant,
211
209
  "firmware": info.firmware,
212
210
  "hardware version": info.hardware_version,
213
211
  "serial number": info.serial_number,
@@ -14,7 +14,7 @@ from typing import Awaitable, Callable, Dict, Iterator, Optional
14
14
  from google.protobuf.message import DecodeError
15
15
  from google.protobuf.message import Message as ProtobufMessage
16
16
 
17
- from .const import NUMERIC_PROPERTY_TYPES, VENTILATION_UNIT_PRODUCT_IDS, GatewayType, ProductId
17
+ from .const import BRIDGE_PRODUCT_IDS, NUMERIC_PROPERTY_TYPES, VENTILATION_UNIT_PRODUCT_IDS, ProductId
18
18
  from .exceptions import (
19
19
  AioComfoConnectNotConnected,
20
20
  AioComfoConnectNotReachable,
@@ -81,6 +81,11 @@ class Node:
81
81
  """Returns True if this node is the ventilation unit that handles RMI commands."""
82
82
  return self.product_id in VENTILATION_UNIT_PRODUCT_IDS
83
83
 
84
+ @property
85
+ def is_bridge(self) -> bool:
86
+ """Returns True if this node is a bridge, like the ComfoConnect LAN C."""
87
+ return self.product_id in BRIDGE_PRODUCT_IDS
88
+
84
89
  @property
85
90
  def is_comfoclime(self) -> bool:
86
91
  """Returns True if this node is a ComfoClime heat pump module."""
@@ -96,12 +101,9 @@ class Bridge:
96
101
  self,
97
102
  host: str,
98
103
  uuid: str,
99
- bridge_type: int = 0,
100
104
  ):
101
105
  self.host: str = host
102
106
  self.uuid: str = uuid
103
- # One of GatewayType. Discovery reports it, and a ComfoConnect Pro also identifies itself when a session starts.
104
- self.bridge_type: int = bridge_type
105
107
  self._local_uuid: Optional[str] = None
106
108
 
107
109
  self._reader: Optional[StreamReader] = None
@@ -113,6 +115,7 @@ class Bridge:
113
115
 
114
116
  self._nodes: Dict[int, Node] = {}
115
117
  self._ventilation_node_found: Optional[asyncio.Event] = None
118
+ self.__node_callback_fn: Optional[Callable[[Node], None]] = None
116
119
 
117
120
  self.__sensor_callback_fn: Optional[Callable[[int, int], None]] = None
118
121
  self._sensor_pdo_types: Dict[int, int] = {}
@@ -134,31 +137,27 @@ class Bridge:
134
137
  """Set a callback to be called when an alarm is received."""
135
138
  self.__alarm_callback_fn = callback
136
139
 
140
+ def set_node_callback(self, callback: Optional[Callable[[Node], None]]):
141
+ """Set a callback to be called every time the bridge announces a node, also when it goes offline (see Node.is_offline).
142
+
143
+ The bridge announces the nodes when a session starts, often more than once, so a node can be announced again.
144
+ """
145
+ self.__node_callback_fn = callback
146
+
137
147
  async def connect(self, uuid: str):
138
148
  """Connect to the bridge and start reading messages."""
139
149
  await self._open_connection(uuid)
140
150
 
141
- async def register(self, uuid: str, name: str, pin: int) -> bool:
151
+ async def register(self, uuid: str, name: str, pin: int) -> None:
142
152
  """Register this app on the bridge and start a session.
143
153
 
144
- For LAN C bridges, attempts to start a session first; if the session
145
- succeeds the app is already registered and no re-registration occurs.
146
- For Pro bridges, registers directly to avoid a connection timeout that
147
- the Pro issues when the app is not yet registered.
148
-
149
- Returns True if the app was newly registered, False if it was already registered.
154
+ Like the official app, this registers directly: a bridge accepts an app that is registered already, as long as
155
+ the PIN is right. We don't start a session first to find out, since a ComfoConnect Pro doesn't answer that for an
156
+ app that isn't registered. ComfoConnectNotAllowed is raised for a wrong PIN.
150
157
  """
151
158
  await self._open_connection(uuid)
152
- if self.bridge_type != GatewayType.PRO:
153
- # LAN C: check whether we are already registered by starting a session.
154
- try:
155
- await self.cmd_start_session()
156
- return False # Already registered; session is now active.
157
- except ComfoConnectNotAllowed:
158
- pass # Not registered yet; fall through to register below.
159
159
  await self.cmd_register_app(uuid, name, pin)
160
160
  await self.cmd_start_session()
161
- return True
162
161
 
163
162
  async def _open_connection(self, uuid: str):
164
163
  """Open TCP connection to the bridge and start reading messages."""
@@ -266,13 +265,15 @@ class Bridge:
266
265
  if node.is_offline:
267
266
  _LOGGER.debug("Node %s went offline", node.node_id)
268
267
  self._nodes.pop(node.node_id, None)
269
- return
268
+ else:
269
+ _LOGGER.debug("Discovered node %s with product id %s in zone %s", node.node_id, node.product_id, node.zone_id)
270
+ self._nodes[node.node_id] = node
270
271
 
271
- _LOGGER.debug("Discovered node %s with product id %s in zone %s", node.node_id, node.product_id, node.zone_id)
272
- self._nodes[node.node_id] = node
272
+ if node.is_ventilation_unit and self._ventilation_node_found is not None:
273
+ self._ventilation_node_found.set()
273
274
 
274
- if node.is_ventilation_unit and self._ventilation_node_found is not None:
275
- self._ventilation_node_found.set()
275
+ if self.__node_callback_fn:
276
+ self.__node_callback_fn(node)
276
277
 
277
278
  @property
278
279
  def nodes(self) -> Dict[int, Node]:
@@ -285,6 +286,15 @@ class Bridge:
285
286
  candidates = [node.node_id for node in self._nodes.values() if node.is_ventilation_unit]
286
287
  return min(candidates) if candidates else None
287
288
 
289
+ @property
290
+ def bridge_node(self) -> Optional[Node]:
291
+ """The node of the bridge itself, or None when the bridge hasn't announced it (yet).
292
+
293
+ A ComfoAir Flex with a ComfoConnect LAN C would have two, and then it's the LAN C (see BRIDGE_PRODUCT_IDS).
294
+ """
295
+ candidates = [node for node in self._nodes.values() if node.is_bridge]
296
+ return min(candidates, key=lambda node: (BRIDGE_PRODUCT_IDS.index(node.product_id), node.node_id)) if candidates else None
297
+
288
298
  @property
289
299
  def comfoclime_node_id(self) -> Optional[int]:
290
300
  """The node id of the ComfoClime, or None when the bridge hasn't announced one."""
@@ -472,16 +482,11 @@ class Bridge:
472
482
  """Starts the session on the device by logging in and optionally disconnecting an already existing session."""
473
483
  _LOGGER.debug("StartSessionRequest")
474
484
  # pylint: disable=no-member
475
- reply = await self._send(
485
+ return await self._send(
476
486
  zehnder_pb2.StartSessionRequest,
477
487
  zehnder_pb2.GatewayOperation.StartSessionRequestType,
478
488
  {"takeover": take_over},
479
489
  )
480
- # A ComfoConnect Pro sets the devicename of a successful session to "ccpro", a LAN C leaves it empty. This also
481
- # tells us the type of a bridge that was connected to by IP address, without discovery.
482
- if getattr(reply, "devicename", None) == "ccpro":
483
- self.bridge_type = GatewayType.PRO
484
- return reply
485
490
 
486
491
  def cmd_close_session(self) -> Awaitable[Message]:
487
492
  """Stops the current session."""
@@ -10,7 +10,7 @@ from dataclasses import dataclass
10
10
  from typing import Any, Awaitable, Callable, Dict, List, Literal, Optional
11
11
 
12
12
  from aiocomfoconnect import Bridge
13
- from aiocomfoconnect.bridge import Message
13
+ from aiocomfoconnect.bridge import Message, Node
14
14
  from aiocomfoconnect.const import (
15
15
  ERRORS,
16
16
  ERRORS_140,
@@ -54,6 +54,7 @@ from aiocomfoconnect.properties import (
54
54
  PROPERTY_HARDWARE_VERSION,
55
55
  PROPERTY_MODEL,
56
56
  PROPERTY_NAME,
57
+ PROPERTY_PRODUCT_VARIANT,
57
58
  PROPERTY_SERIAL_NUMBER,
58
59
  Property,
59
60
  PropertyConstraints,
@@ -120,6 +121,7 @@ class NodeInfo:
120
121
  serial_number: Optional[str]
121
122
  firmware: Optional[str]
122
123
  hardware_version: Optional[int]
124
+ product_variant: Optional[int] # Which model of the product, e.g. 3 is a Q600 for a ComfoAir Q (see PROTOCOL-RMI.md).
123
125
 
124
126
 
125
127
  @dataclass
@@ -144,9 +146,9 @@ class ComfoConnect(Bridge):
144
146
  alarm_callback=None,
145
147
  sensor_delay=5,
146
148
  connect_timeout=30,
147
- bridge_type: int = 0,
148
149
  heartbeat_interval: Optional[float] = HEARTBEAT_INTERVAL,
149
150
  connection_state_callback: Optional[Callable[[str], None]] = None,
151
+ node_callback: Optional[Callable[[Node], None]] = None,
150
152
  ):
151
153
  """Initialize the ComfoConnect class.
152
154
 
@@ -155,11 +157,15 @@ class ComfoConnect(Bridge):
155
157
  that stopped answering without closing the connection. None disables it.
156
158
 
157
159
  The connection_state_callback is called with a ConnectionState when the state of the session changes.
160
+
161
+ The node_callback is called with a Node every time the bridge announces one: at the start of every session, already
162
+ while connect() runs and often more than once, and when a node joins or goes offline (see Node.is_offline).
158
163
  """
159
- super().__init__(host, uuid, bridge_type)
164
+ super().__init__(host, uuid)
160
165
 
161
166
  self.set_sensor_callback(self._sensor_callback) # Set the callback to our _sensor_callback method, so we can proces the callbacks.
162
167
  self.set_alarm_callback(self._alarm_callback) # Set the callback to our _alarm_callback method, so we can proces the callbacks.
168
+ self.set_node_callback(node_callback)
163
169
  self.sensor_delay = sensor_delay
164
170
  self.connect_timeout = connect_timeout
165
171
  self.heartbeat_interval = heartbeat_interval
@@ -481,31 +487,36 @@ class ComfoConnect(Bridge):
481
487
  return values
482
488
 
483
489
  async def get_node_info(self, node_id: Optional[int] = None) -> NodeInfo:
484
- """Get the NodeInfo of a node (the ventilation unit by default), in one request when the node has all its properties.
490
+ """Get the NodeInfo of a node (the ventilation unit by default). A property that the node doesn't have is None.
485
491
 
486
- Raises ComfoConnectRmiError when none of the properties can be read, e.g. for a node that doesn't exist.
492
+ The properties are read one by one: a node fails a request for several as a whole when it lacks one of them, and
493
+ a ComfoConnect Pro answers it with fewer values than asked. Raises ComfoConnectRmiError when none of the
494
+ properties can be read, e.g. for a node that doesn't exist.
487
495
  """
488
- props = [PROPERTY_NAME, PROPERTY_MODEL, PROPERTY_ARTICLE, PROPERTY_SERIAL_NUMBER, PROPERTY_FIRMWARE_VERSION, PROPERTY_HARDWARE_VERSION]
489
- try:
490
- return NodeInfo(*await self.get_properties(props, node_id))
491
- except ComfoConnectRmiError as exc:
492
- error = exc
496
+ props = [PROPERTY_NAME, PROPERTY_MODEL, PROPERTY_ARTICLE, PROPERTY_SERIAL_NUMBER, PROPERTY_FIRMWARE_VERSION, PROPERTY_HARDWARE_VERSION, PROPERTY_PRODUCT_VARIANT]
497
+ errors: List[ComfoConnectRmiError] = []
493
498
 
494
- # A request fails as a whole when the node lacks one of the properties, so read them one by one.
495
499
  async def get_or_none(prop: Property) -> Any:
496
500
  try:
497
501
  return await self.get_property(prop, node_id)
498
- except ComfoConnectRmiError:
502
+ except ComfoConnectRmiError as exc:
503
+ errors.append(exc)
499
504
  return None
500
505
 
501
506
  values = [await get_or_none(prop) for prop in props]
502
- if all(value is None for value in values):
503
- raise error # Nothing could be read, e.g. the node doesn't exist.
507
+ if len(errors) == len(props):
508
+ raise errors[0]
504
509
  return NodeInfo(*values)
505
510
 
506
511
  async def get_single_property(self, unit: int, subunit: int, property_id: int, property_type: int = None, node_id: Optional[int] = None) -> Any:
507
- """Get a property and convert to the right type."""
512
+ """Get a property and convert to the right type.
513
+
514
+ Raises ComfoConnectRmiError when the node doesn't have the property: it answers with an RMI error, or, like the
515
+ node of a ComfoConnect Pro, with an empty message.
516
+ """
508
517
  result = await self.cmd_rmi_request(bytes([0x01, unit, subunit, 0x10, property_id]), node_id=node_id)
518
+ if not result.message:
519
+ raise ComfoConnectRmiError(f"The node sent no value for property {property_id}")
509
520
  return _decode_value(property_type, result.message)
510
521
 
511
522
  async def get_property_constraints(self, prop: Property, node_id: Optional[int] = None) -> PropertyConstraints:
@@ -30,16 +30,12 @@ class ProductId:
30
30
  # nodes on the bus (gateway, connection board, sensors, ...) will reply with RMI_ERROR.
31
31
  VENTILATION_UNIT_PRODUCT_IDS = (ProductId.COMFOAIRQ, ProductId.COMFOAIRFLEX)
32
32
 
33
-
34
- # PDO Types
35
- class GatewayType:
36
- """Defines the type of a bridge, with the values of the GatewayType in the discovery response."""
37
-
38
- LANC = 0 # ComfoConnect LAN C
39
- SEASON = 1 # The built-in WiFi module of a ComfoAir Flex
40
- PRO = 2 # ComfoConnect Pro
33
+ # The product ids of the bridge itself on the bus, in order of preference: a ComfoConnect Pro, a ComfoConnect LAN C,
34
+ # and the WiFi connection module built into a ComfoAir Flex. A Flex with a LAN C would have both of the last two.
35
+ BRIDGE_PRODUCT_IDS = (ProductId.COMFOCONNECTPRO, ProductId.ZEHNDERGATEWAY, ProductId.COMFOAIRFLEXCONNECTIONBOARD)
41
36
 
42
37
 
38
+ # PDO Types
43
39
  class ConnectionState:
44
40
  """The state of the session with the bridge, as reported to the connection state callback."""
45
41
 
@@ -55,12 +51,14 @@ class PdoType:
55
51
  TYPE_CN_UINT8 = 0x01
56
52
  TYPE_CN_UINT16 = 0x02
57
53
  TYPE_CN_UINT32 = 0x03
54
+ TYPE_CN_UINT64 = 0x04
58
55
  TYPE_CN_INT8 = 0x05
59
56
  TYPE_CN_INT16 = 0x06
57
+ TYPE_CN_INT32 = 0x07
60
58
  TYPE_CN_INT64 = 0x08
61
59
  TYPE_CN_STRING = 0x09
62
- TYPE_CN_TIME = 0x10
63
- TYPE_CN_VERSION = 0x11
60
+ TYPE_CN_TIME = 0x0A
61
+ TYPE_CN_VERSION = 0x0B
64
62
 
65
63
 
66
64
  # The size in bytes and the signedness of the numeric PDO and property types.
@@ -68,8 +66,10 @@ NUMERIC_PROPERTY_TYPES = {
68
66
  PdoType.TYPE_CN_UINT8: (1, False),
69
67
  PdoType.TYPE_CN_UINT16: (2, False),
70
68
  PdoType.TYPE_CN_UINT32: (4, False),
69
+ PdoType.TYPE_CN_UINT64: (8, False),
71
70
  PdoType.TYPE_CN_INT8: (1, True),
72
71
  PdoType.TYPE_CN_INT16: (2, True),
72
+ PdoType.TYPE_CN_INT32: (4, True),
73
73
  PdoType.TYPE_CN_INT64: (8, True),
74
74
  }
75
75
 
@@ -77,7 +77,6 @@ class BridgeDiscoveryProtocol(asyncio.DatagramProtocol):
77
77
  Bridge(
78
78
  host=parser.searchGatewayResponse.ipaddress,
79
79
  uuid=uuid,
80
- bridge_type=parser.searchGatewayResponse.type,
81
80
  )
82
81
  )
83
82
 
@@ -49,6 +49,7 @@ class PropertyConstraints:
49
49
  step: int | float
50
50
 
51
51
 
52
+ PROPERTY_PRODUCT_VARIANT = Property(UNIT_NODE, 0x01, 0x03, PdoType.TYPE_CN_UINT8) # E.g. 1=Q350, 2=Q450, 3=Q600 on a ComfoAir Q.
52
53
  PROPERTY_SERIAL_NUMBER = Property(UNIT_NODE, 0x01, 0x04, PdoType.TYPE_CN_STRING)
53
54
  PROPERTY_HARDWARE_VERSION = Property(UNIT_NODE, 0x01, 0x05, PdoType.TYPE_CN_UINT8)
54
55
  PROPERTY_FIRMWARE_VERSION = Property(UNIT_NODE, 0x01, 0x06, PdoType.TYPE_CN_VERSION) # A UINT32, decoded with version_decode().
@@ -1,6 +1,6 @@
1
1
  [tool.poetry]
2
2
  name = "aiocomfoconnect"
3
- version = "0.4.4"
3
+ version = "0.4.5"
4
4
  description = "aiocomfoconnect is an asyncio Python 3 library for communicating with a Zehnder ComfoAir Q350/450/600 ventilation system"
5
5
  authors = ["Michaël Arnauts <michael.arnauts@gmail.com>"]
6
6
  license = "MIT"