aiocomfoconnect 0.4.3__tar.gz → 0.4.5__tar.gz
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- {aiocomfoconnect-0.4.3 → aiocomfoconnect-0.4.5}/PKG-INFO +6 -4
- {aiocomfoconnect-0.4.3 → aiocomfoconnect-0.4.5}/README.md +5 -3
- {aiocomfoconnect-0.4.3 → aiocomfoconnect-0.4.5}/aiocomfoconnect/__main__.py +4 -6
- {aiocomfoconnect-0.4.3 → aiocomfoconnect-0.4.5}/aiocomfoconnect/bridge.py +39 -32
- {aiocomfoconnect-0.4.3 → aiocomfoconnect-0.4.5}/aiocomfoconnect/comfoconnect.py +55 -27
- {aiocomfoconnect-0.4.3 → aiocomfoconnect-0.4.5}/aiocomfoconnect/const.py +10 -10
- {aiocomfoconnect-0.4.3 → aiocomfoconnect-0.4.5}/aiocomfoconnect/discovery.py +0 -1
- {aiocomfoconnect-0.4.3 → aiocomfoconnect-0.4.5}/aiocomfoconnect/properties.py +1 -0
- {aiocomfoconnect-0.4.3 → aiocomfoconnect-0.4.5}/pyproject.toml +1 -1
- {aiocomfoconnect-0.4.3 → aiocomfoconnect-0.4.5}/LICENSE +0 -0
- {aiocomfoconnect-0.4.3 → aiocomfoconnect-0.4.5}/aiocomfoconnect/__init__.py +0 -0
- {aiocomfoconnect-0.4.3 → aiocomfoconnect-0.4.5}/aiocomfoconnect/exceptions.py +0 -0
- {aiocomfoconnect-0.4.3 → aiocomfoconnect-0.4.5}/aiocomfoconnect/protobuf/nanopb_pb2.py +0 -0
- {aiocomfoconnect-0.4.3 → aiocomfoconnect-0.4.5}/aiocomfoconnect/protobuf/zehnder_pb2.py +0 -0
- {aiocomfoconnect-0.4.3 → aiocomfoconnect-0.4.5}/aiocomfoconnect/sensors.py +0 -0
- {aiocomfoconnect-0.4.3 → aiocomfoconnect-0.4.5}/aiocomfoconnect/util.py +0 -0
|
@@ -1,6 +1,6 @@
|
|
|
1
1
|
Metadata-Version: 2.4
|
|
2
2
|
Name: aiocomfoconnect
|
|
3
|
-
Version: 0.4.
|
|
3
|
+
Version: 0.4.5
|
|
4
4
|
Summary: aiocomfoconnect is an asyncio Python 3 library for communicating with a Zehnder ComfoAir Q350/450/600 ventilation system
|
|
5
5
|
License: MIT
|
|
6
6
|
License-File: LICENSE
|
|
@@ -63,11 +63,14 @@ $ python -m aiocomfoconnect set-property --host 192.168.1.213 30 1 4 6 120 # Se
|
|
|
63
63
|
|
|
64
64
|
## Available methods
|
|
65
65
|
|
|
66
|
-
- `async connect()`: Connect to the bridge. The connection is kept: when it is lost, it reconnects, and when nothing was received for `heartbeat_interval` seconds (30 by default, `None` disables it), it
|
|
66
|
+
- `async connect()`: Connect to the bridge. The connection is kept: when it is lost, it reconnects, and when nothing was sent or received for `heartbeat_interval` seconds (30 by default, `None` disables it), it asks the bridge for its time. That keeps the bridge from closing the connection (it does so after about 90 seconds in which the client sent nothing, even while it pushes sensor values), and detects a bridge that stopped answering.
|
|
67
67
|
- `connection_state_callback`: Pass it to `ComfoConnect()` to be called with a `ConnectionState` when the state of the session changes.
|
|
68
|
+
- `node_callback`: Pass it to `ComfoConnect()` to be called with a `Node` every time the bridge announces one: at the start of every session (already while `connect()` runs, and often more than once), and when a node joins or goes offline (`node.is_offline`).
|
|
68
69
|
- `async disconnect()`: Disconnect from the bridge.
|
|
69
70
|
- `async register_sensor(sensor)`: Register a sensor.
|
|
70
71
|
- `async deregister_sensor(sensor)`: Deregister a sensor.
|
|
72
|
+
- `sensor_values`: The latest value of every registered sensor, by sensor id, converted like for the sensor callback (`None` until the bridge sent one).
|
|
73
|
+
- `bridge_node`: The `Node` of the bridge itself on the ComfoNet bus: product id 222 for a ComfoConnect Pro, 5 for a ComfoConnect LAN C, or 9 for the WiFi connection module of a ComfoAir Flex. It is `None` when the bridge didn't announce it (yet): it does so a little after the ventilation unit.
|
|
71
74
|
- `async get_mode()`: Get the ventilation mode.
|
|
72
75
|
- `async set_mode(mode)`: Set the ventilation mode. (auto / manual) Selecting `auto` also cancels the temporary fan-speed override and returns control to the unit's schedule.
|
|
73
76
|
- `async get_comfocool_mode()`: Get Comfocool mode
|
|
@@ -86,13 +89,12 @@ $ python -m aiocomfoconnect set-property --host 192.168.1.213 30 1 4 6 120 # Se
|
|
|
86
89
|
- `async set_temperature_profile(profile)`: Set the temperature profile. (warm / normal / cool)
|
|
87
90
|
- `async get_property(prop, node_id=None)`: Get the value of a property, e.g. `PROPERTY_RMOT_HEATING_THRESHOLD`. It is read from the node the property lives on: the ventilation unit, or the ComfoClime for the `PROPERTY_CLIME_*` properties. Pass `node_id` to read it from another node. A `NodeNotFoundException` is raised when the node isn't on the bus.
|
|
88
91
|
- `async get_properties(props, node_id=None)`: Get several properties of one node in one request, converted like `get_property`, e.g. `await comfoconnect.get_properties([PROPERTY_MODEL, PROPERTY_SERIAL_NUMBER])`.
|
|
89
|
-
- `async get_node_info(node_id=None)`: Get the `NodeInfo` (name, model, article number, serial number, firmware version and
|
|
92
|
+
- `async get_node_info(node_id=None)`: Get the `NodeInfo` (name, model, article number, serial number, firmware version, hardware version and product variant) of a node, the ventilation unit by default, in one request. A property that the node doesn't have, like the model of the bridge, is `None`.
|
|
90
93
|
- `async set_property(prop, value, node_id=None)`: Set a property, on the same node as `get_property`.
|
|
91
94
|
- The airflow in m³/h of each fan speed is a property: `PROPERTY_FLOW_AWAY`, `PROPERTY_FLOW_LOW`, `PROPERTY_FLOW_MEDIUM` and `PROPERTY_FLOW_HIGH`, e.g. `await comfoconnect.set_property(PROPERTY_FLOW_LOW, 120)`.
|
|
92
95
|
- Properties that are an enum, like `PROPERTY_SENSOR_VENTILATION_TEMP_PASSIVE`, `PROPERTY_SENSOR_VENTILATION_HUMIDITY_COMFORT` and `PROPERTY_SENSOR_VENTILATION_HUMIDITY_PROTECTION` (off / auto / on), `PROPERTY_TEMPERATURE_PROFILE_MODE` (adaptive / fixed), `PROPERTY_CLIME_SEASON` and `PROPERTY_CLIME_TEMPERATURE_PROFILE`, have `options`: `get_property` returns the option and `set_property` takes it. `get_property_constraints` still uses the raw values.
|
|
93
96
|
- Temperatures in tenths of a degree, like `PROPERTY_RMOT_HEATING_THRESHOLD`, `PROPERTY_PROFILE_TEMPERATURE_NORMAL` and the ComfoClime temperatures, have `scale=0.1`: `get_property` and `get_property_constraints` return °C (215 becomes 21.5) and `set_property` takes °C.
|
|
94
97
|
- `async get_property_constraints(prop, node_id=None)`: Get the value of a numeric property, together with the range and step size the unit accepts.
|
|
95
|
-
- `bridge_type`: The type of the bridge (`GatewayType.LANC`, `SEASON` or `PRO`). Discovery reports it, and a ComfoConnect Pro is also recognised once a session has started.
|
|
96
98
|
|
|
97
99
|
### Low-level API
|
|
98
100
|
|
|
@@ -45,11 +45,14 @@ $ python -m aiocomfoconnect set-property --host 192.168.1.213 30 1 4 6 120 # Se
|
|
|
45
45
|
|
|
46
46
|
## Available methods
|
|
47
47
|
|
|
48
|
-
- `async connect()`: Connect to the bridge. The connection is kept: when it is lost, it reconnects, and when nothing was received for `heartbeat_interval` seconds (30 by default, `None` disables it), it
|
|
48
|
+
- `async connect()`: Connect to the bridge. The connection is kept: when it is lost, it reconnects, and when nothing was sent or received for `heartbeat_interval` seconds (30 by default, `None` disables it), it asks the bridge for its time. That keeps the bridge from closing the connection (it does so after about 90 seconds in which the client sent nothing, even while it pushes sensor values), and detects a bridge that stopped answering.
|
|
49
49
|
- `connection_state_callback`: Pass it to `ComfoConnect()` to be called with a `ConnectionState` when the state of the session changes.
|
|
50
|
+
- `node_callback`: Pass it to `ComfoConnect()` to be called with a `Node` every time the bridge announces one: at the start of every session (already while `connect()` runs, and often more than once), and when a node joins or goes offline (`node.is_offline`).
|
|
50
51
|
- `async disconnect()`: Disconnect from the bridge.
|
|
51
52
|
- `async register_sensor(sensor)`: Register a sensor.
|
|
52
53
|
- `async deregister_sensor(sensor)`: Deregister a sensor.
|
|
54
|
+
- `sensor_values`: The latest value of every registered sensor, by sensor id, converted like for the sensor callback (`None` until the bridge sent one).
|
|
55
|
+
- `bridge_node`: The `Node` of the bridge itself on the ComfoNet bus: product id 222 for a ComfoConnect Pro, 5 for a ComfoConnect LAN C, or 9 for the WiFi connection module of a ComfoAir Flex. It is `None` when the bridge didn't announce it (yet): it does so a little after the ventilation unit.
|
|
53
56
|
- `async get_mode()`: Get the ventilation mode.
|
|
54
57
|
- `async set_mode(mode)`: Set the ventilation mode. (auto / manual) Selecting `auto` also cancels the temporary fan-speed override and returns control to the unit's schedule.
|
|
55
58
|
- `async get_comfocool_mode()`: Get Comfocool mode
|
|
@@ -68,13 +71,12 @@ $ python -m aiocomfoconnect set-property --host 192.168.1.213 30 1 4 6 120 # Se
|
|
|
68
71
|
- `async set_temperature_profile(profile)`: Set the temperature profile. (warm / normal / cool)
|
|
69
72
|
- `async get_property(prop, node_id=None)`: Get the value of a property, e.g. `PROPERTY_RMOT_HEATING_THRESHOLD`. It is read from the node the property lives on: the ventilation unit, or the ComfoClime for the `PROPERTY_CLIME_*` properties. Pass `node_id` to read it from another node. A `NodeNotFoundException` is raised when the node isn't on the bus.
|
|
70
73
|
- `async get_properties(props, node_id=None)`: Get several properties of one node in one request, converted like `get_property`, e.g. `await comfoconnect.get_properties([PROPERTY_MODEL, PROPERTY_SERIAL_NUMBER])`.
|
|
71
|
-
- `async get_node_info(node_id=None)`: Get the `NodeInfo` (name, model, article number, serial number, firmware version and
|
|
74
|
+
- `async get_node_info(node_id=None)`: Get the `NodeInfo` (name, model, article number, serial number, firmware version, hardware version and product variant) of a node, the ventilation unit by default, in one request. A property that the node doesn't have, like the model of the bridge, is `None`.
|
|
72
75
|
- `async set_property(prop, value, node_id=None)`: Set a property, on the same node as `get_property`.
|
|
73
76
|
- The airflow in m³/h of each fan speed is a property: `PROPERTY_FLOW_AWAY`, `PROPERTY_FLOW_LOW`, `PROPERTY_FLOW_MEDIUM` and `PROPERTY_FLOW_HIGH`, e.g. `await comfoconnect.set_property(PROPERTY_FLOW_LOW, 120)`.
|
|
74
77
|
- Properties that are an enum, like `PROPERTY_SENSOR_VENTILATION_TEMP_PASSIVE`, `PROPERTY_SENSOR_VENTILATION_HUMIDITY_COMFORT` and `PROPERTY_SENSOR_VENTILATION_HUMIDITY_PROTECTION` (off / auto / on), `PROPERTY_TEMPERATURE_PROFILE_MODE` (adaptive / fixed), `PROPERTY_CLIME_SEASON` and `PROPERTY_CLIME_TEMPERATURE_PROFILE`, have `options`: `get_property` returns the option and `set_property` takes it. `get_property_constraints` still uses the raw values.
|
|
75
78
|
- Temperatures in tenths of a degree, like `PROPERTY_RMOT_HEATING_THRESHOLD`, `PROPERTY_PROFILE_TEMPERATURE_NORMAL` and the ComfoClime temperatures, have `scale=0.1`: `get_property` and `get_property_constraints` return °C (215 becomes 21.5) and `set_property` takes °C.
|
|
76
79
|
- `async get_property_constraints(prop, node_id=None)`: Get the value of a numeric property, together with the range and step size the unit accepts.
|
|
77
|
-
- `bridge_type`: The type of the bridge (`GatewayType.LANC`, `SEASON` or `PRO`). Discovery reports it, and a ComfoConnect Pro is also recognised once a session has started.
|
|
78
80
|
|
|
79
81
|
### Low-level API
|
|
80
82
|
|
|
@@ -43,7 +43,7 @@ async def connected(args, *, connect: bool = True, **kwargs) -> AsyncIterator[Co
|
|
|
43
43
|
if not bridges:
|
|
44
44
|
raise BridgeNotFoundException("No bridge found")
|
|
45
45
|
|
|
46
|
-
comfoconnect = ComfoConnect(bridges[0].host, bridges[0].uuid,
|
|
46
|
+
comfoconnect = ComfoConnect(bridges[0].host, bridges[0].uuid, **kwargs)
|
|
47
47
|
try:
|
|
48
48
|
if connect:
|
|
49
49
|
try:
|
|
@@ -82,14 +82,11 @@ async def run_register(args):
|
|
|
82
82
|
"""Register an app on the bridge."""
|
|
83
83
|
async with connected(args, connect=False) as comfoconnect:
|
|
84
84
|
try:
|
|
85
|
-
|
|
85
|
+
await comfoconnect.register(args.uuid, args.name, args.pin)
|
|
86
86
|
except ComfoConnectNotAllowed as exc:
|
|
87
87
|
raise CliError("Registration failed. Please check the PIN.") from exc
|
|
88
88
|
|
|
89
|
-
|
|
90
|
-
print(f"UUID {args.uuid} is now registered.")
|
|
91
|
-
else:
|
|
92
|
-
print(f"UUID {args.uuid} is already registered.")
|
|
89
|
+
print(f"UUID {args.uuid} is registered.")
|
|
93
90
|
|
|
94
91
|
await print_registered_apps(comfoconnect)
|
|
95
92
|
|
|
@@ -208,6 +205,7 @@ async def run_list_nodes(args):
|
|
|
208
205
|
fields = {
|
|
209
206
|
"name": info.name,
|
|
210
207
|
"model": info.model,
|
|
208
|
+
"product variant": info.product_variant,
|
|
211
209
|
"firmware": info.firmware,
|
|
212
210
|
"hardware version": info.hardware_version,
|
|
213
211
|
"serial number": info.serial_number,
|
|
@@ -14,7 +14,7 @@ from typing import Awaitable, Callable, Dict, Iterator, Optional
|
|
|
14
14
|
from google.protobuf.message import DecodeError
|
|
15
15
|
from google.protobuf.message import Message as ProtobufMessage
|
|
16
16
|
|
|
17
|
-
from .const import NUMERIC_PROPERTY_TYPES, VENTILATION_UNIT_PRODUCT_IDS,
|
|
17
|
+
from .const import BRIDGE_PRODUCT_IDS, NUMERIC_PROPERTY_TYPES, VENTILATION_UNIT_PRODUCT_IDS, ProductId
|
|
18
18
|
from .exceptions import (
|
|
19
19
|
AioComfoConnectNotConnected,
|
|
20
20
|
AioComfoConnectNotReachable,
|
|
@@ -81,6 +81,11 @@ class Node:
|
|
|
81
81
|
"""Returns True if this node is the ventilation unit that handles RMI commands."""
|
|
82
82
|
return self.product_id in VENTILATION_UNIT_PRODUCT_IDS
|
|
83
83
|
|
|
84
|
+
@property
|
|
85
|
+
def is_bridge(self) -> bool:
|
|
86
|
+
"""Returns True if this node is a bridge, like the ComfoConnect LAN C."""
|
|
87
|
+
return self.product_id in BRIDGE_PRODUCT_IDS
|
|
88
|
+
|
|
84
89
|
@property
|
|
85
90
|
def is_comfoclime(self) -> bool:
|
|
86
91
|
"""Returns True if this node is a ComfoClime heat pump module."""
|
|
@@ -96,12 +101,9 @@ class Bridge:
|
|
|
96
101
|
self,
|
|
97
102
|
host: str,
|
|
98
103
|
uuid: str,
|
|
99
|
-
bridge_type: int = 0,
|
|
100
104
|
):
|
|
101
105
|
self.host: str = host
|
|
102
106
|
self.uuid: str = uuid
|
|
103
|
-
# One of GatewayType. Discovery reports it, and a ComfoConnect Pro also identifies itself when a session starts.
|
|
104
|
-
self.bridge_type: int = bridge_type
|
|
105
107
|
self._local_uuid: Optional[str] = None
|
|
106
108
|
|
|
107
109
|
self._reader: Optional[StreamReader] = None
|
|
@@ -113,14 +115,16 @@ class Bridge:
|
|
|
113
115
|
|
|
114
116
|
self._nodes: Dict[int, Node] = {}
|
|
115
117
|
self._ventilation_node_found: Optional[asyncio.Event] = None
|
|
118
|
+
self.__node_callback_fn: Optional[Callable[[Node], None]] = None
|
|
116
119
|
|
|
117
120
|
self.__sensor_callback_fn: Optional[Callable[[int, int], None]] = None
|
|
118
121
|
self._sensor_pdo_types: Dict[int, int] = {}
|
|
119
122
|
self.__alarm_callback_fn: Optional[Callable[[int, ProtobufMessage], None]] = None
|
|
120
123
|
|
|
121
124
|
self._read_task = None
|
|
122
|
-
# The time.monotonic() of the last message we received from the bridge.
|
|
125
|
+
# The time.monotonic() of the last message we received from the bridge, and of the last one we sent.
|
|
123
126
|
self._last_received: float = 0
|
|
127
|
+
self._last_sent: float = 0
|
|
124
128
|
|
|
125
129
|
def __repr__(self):
|
|
126
130
|
return f"<Bridge {self.host}, UID={self.uuid}>"
|
|
@@ -133,31 +137,27 @@ class Bridge:
|
|
|
133
137
|
"""Set a callback to be called when an alarm is received."""
|
|
134
138
|
self.__alarm_callback_fn = callback
|
|
135
139
|
|
|
140
|
+
def set_node_callback(self, callback: Optional[Callable[[Node], None]]):
|
|
141
|
+
"""Set a callback to be called every time the bridge announces a node, also when it goes offline (see Node.is_offline).
|
|
142
|
+
|
|
143
|
+
The bridge announces the nodes when a session starts, often more than once, so a node can be announced again.
|
|
144
|
+
"""
|
|
145
|
+
self.__node_callback_fn = callback
|
|
146
|
+
|
|
136
147
|
async def connect(self, uuid: str):
|
|
137
148
|
"""Connect to the bridge and start reading messages."""
|
|
138
149
|
await self._open_connection(uuid)
|
|
139
150
|
|
|
140
|
-
async def register(self, uuid: str, name: str, pin: int) ->
|
|
151
|
+
async def register(self, uuid: str, name: str, pin: int) -> None:
|
|
141
152
|
"""Register this app on the bridge and start a session.
|
|
142
153
|
|
|
143
|
-
|
|
144
|
-
|
|
145
|
-
|
|
146
|
-
the Pro issues when the app is not yet registered.
|
|
147
|
-
|
|
148
|
-
Returns True if the app was newly registered, False if it was already registered.
|
|
154
|
+
Like the official app, this registers directly: a bridge accepts an app that is registered already, as long as
|
|
155
|
+
the PIN is right. We don't start a session first to find out, since a ComfoConnect Pro doesn't answer that for an
|
|
156
|
+
app that isn't registered. ComfoConnectNotAllowed is raised for a wrong PIN.
|
|
149
157
|
"""
|
|
150
158
|
await self._open_connection(uuid)
|
|
151
|
-
if self.bridge_type != GatewayType.PRO:
|
|
152
|
-
# LAN C: check whether we are already registered by starting a session.
|
|
153
|
-
try:
|
|
154
|
-
await self.cmd_start_session()
|
|
155
|
-
return False # Already registered; session is now active.
|
|
156
|
-
except ComfoConnectNotAllowed:
|
|
157
|
-
pass # Not registered yet; fall through to register below.
|
|
158
159
|
await self.cmd_register_app(uuid, name, pin)
|
|
159
160
|
await self.cmd_start_session()
|
|
160
|
-
return True
|
|
161
161
|
|
|
162
162
|
async def _open_connection(self, uuid: str):
|
|
163
163
|
"""Open TCP connection to the bridge and start reading messages."""
|
|
@@ -182,7 +182,7 @@ class Bridge:
|
|
|
182
182
|
|
|
183
183
|
self._reference = itertools.count(1)
|
|
184
184
|
self._local_uuid = uuid
|
|
185
|
-
self._last_received = time.monotonic()
|
|
185
|
+
self._last_received = self._last_sent = time.monotonic()
|
|
186
186
|
self._pending = {}
|
|
187
187
|
|
|
188
188
|
# The bridge announces its nodes at the start of every session, so forget what we knew.
|
|
@@ -265,13 +265,15 @@ class Bridge:
|
|
|
265
265
|
if node.is_offline:
|
|
266
266
|
_LOGGER.debug("Node %s went offline", node.node_id)
|
|
267
267
|
self._nodes.pop(node.node_id, None)
|
|
268
|
-
|
|
268
|
+
else:
|
|
269
|
+
_LOGGER.debug("Discovered node %s with product id %s in zone %s", node.node_id, node.product_id, node.zone_id)
|
|
270
|
+
self._nodes[node.node_id] = node
|
|
269
271
|
|
|
270
|
-
|
|
271
|
-
|
|
272
|
+
if node.is_ventilation_unit and self._ventilation_node_found is not None:
|
|
273
|
+
self._ventilation_node_found.set()
|
|
272
274
|
|
|
273
|
-
if
|
|
274
|
-
self.
|
|
275
|
+
if self.__node_callback_fn:
|
|
276
|
+
self.__node_callback_fn(node)
|
|
275
277
|
|
|
276
278
|
@property
|
|
277
279
|
def nodes(self) -> Dict[int, Node]:
|
|
@@ -284,6 +286,15 @@ class Bridge:
|
|
|
284
286
|
candidates = [node.node_id for node in self._nodes.values() if node.is_ventilation_unit]
|
|
285
287
|
return min(candidates) if candidates else None
|
|
286
288
|
|
|
289
|
+
@property
|
|
290
|
+
def bridge_node(self) -> Optional[Node]:
|
|
291
|
+
"""The node of the bridge itself, or None when the bridge hasn't announced it (yet).
|
|
292
|
+
|
|
293
|
+
A ComfoAir Flex with a ComfoConnect LAN C would have two, and then it's the LAN C (see BRIDGE_PRODUCT_IDS).
|
|
294
|
+
"""
|
|
295
|
+
candidates = [node for node in self._nodes.values() if node.is_bridge]
|
|
296
|
+
return min(candidates, key=lambda node: (BRIDGE_PRODUCT_IDS.index(node.product_id), node.node_id)) if candidates else None
|
|
297
|
+
|
|
287
298
|
@property
|
|
288
299
|
def comfoclime_node_id(self) -> Optional[int]:
|
|
289
300
|
"""The node id of the ComfoClime, or None when the bridge hasn't announced one."""
|
|
@@ -407,6 +418,7 @@ class Bridge:
|
|
|
407
418
|
try:
|
|
408
419
|
self._writer.write(message.encode())
|
|
409
420
|
await self._writer.drain()
|
|
421
|
+
self._last_sent = time.monotonic()
|
|
410
422
|
except (ConnectionError, OSError) as exc:
|
|
411
423
|
_LOGGER.warning("Failed to send message: %s", exc)
|
|
412
424
|
raise AioComfoConnectNotConnected("Connection lost while sending") from exc
|
|
@@ -470,16 +482,11 @@ class Bridge:
|
|
|
470
482
|
"""Starts the session on the device by logging in and optionally disconnecting an already existing session."""
|
|
471
483
|
_LOGGER.debug("StartSessionRequest")
|
|
472
484
|
# pylint: disable=no-member
|
|
473
|
-
|
|
485
|
+
return await self._send(
|
|
474
486
|
zehnder_pb2.StartSessionRequest,
|
|
475
487
|
zehnder_pb2.GatewayOperation.StartSessionRequestType,
|
|
476
488
|
{"takeover": take_over},
|
|
477
489
|
)
|
|
478
|
-
# A ComfoConnect Pro sets the devicename of a successful session to "ccpro", a LAN C leaves it empty. This also
|
|
479
|
-
# tells us the type of a bridge that was connected to by IP address, without discovery.
|
|
480
|
-
if getattr(reply, "devicename", None) == "ccpro":
|
|
481
|
-
self.bridge_type = GatewayType.PRO
|
|
482
|
-
return reply
|
|
483
490
|
|
|
484
491
|
def cmd_close_session(self) -> Awaitable[Message]:
|
|
485
492
|
"""Stops the current session."""
|
|
@@ -10,7 +10,7 @@ from dataclasses import dataclass
|
|
|
10
10
|
from typing import Any, Awaitable, Callable, Dict, List, Literal, Optional
|
|
11
11
|
|
|
12
12
|
from aiocomfoconnect import Bridge
|
|
13
|
-
from aiocomfoconnect.bridge import Message
|
|
13
|
+
from aiocomfoconnect.bridge import Message, Node
|
|
14
14
|
from aiocomfoconnect.const import (
|
|
15
15
|
ERRORS,
|
|
16
16
|
ERRORS_140,
|
|
@@ -54,6 +54,7 @@ from aiocomfoconnect.properties import (
|
|
|
54
54
|
PROPERTY_HARDWARE_VERSION,
|
|
55
55
|
PROPERTY_MODEL,
|
|
56
56
|
PROPERTY_NAME,
|
|
57
|
+
PROPERTY_PRODUCT_VARIANT,
|
|
57
58
|
PROPERTY_SERIAL_NUMBER,
|
|
58
59
|
Property,
|
|
59
60
|
PropertyConstraints,
|
|
@@ -96,6 +97,11 @@ def _decode_value(property_type: Optional[int], raw: bytes) -> Any:
|
|
|
96
97
|
return raw
|
|
97
98
|
|
|
98
99
|
|
|
100
|
+
def _sensor_value(sensor: Sensor, raw: int) -> Any:
|
|
101
|
+
"""Convert the raw value of a sensor."""
|
|
102
|
+
return sensor.value_fn(raw) if sensor.value_fn else round(raw, 2)
|
|
103
|
+
|
|
104
|
+
|
|
99
105
|
def _property_value(prop: Property, value: Any) -> Any:
|
|
100
106
|
"""Return the option or the scaled value of a decoded property value."""
|
|
101
107
|
if prop.options is None:
|
|
@@ -115,6 +121,7 @@ class NodeInfo:
|
|
|
115
121
|
serial_number: Optional[str]
|
|
116
122
|
firmware: Optional[str]
|
|
117
123
|
hardware_version: Optional[int]
|
|
124
|
+
product_variant: Optional[int] # Which model of the product, e.g. 3 is a Q600 for a ComfoAir Q (see PROTOCOL-RMI.md).
|
|
118
125
|
|
|
119
126
|
|
|
120
127
|
@dataclass
|
|
@@ -139,21 +146,26 @@ class ComfoConnect(Bridge):
|
|
|
139
146
|
alarm_callback=None,
|
|
140
147
|
sensor_delay=5,
|
|
141
148
|
connect_timeout=30,
|
|
142
|
-
bridge_type: int = 0,
|
|
143
149
|
heartbeat_interval: Optional[float] = HEARTBEAT_INTERVAL,
|
|
144
150
|
connection_state_callback: Optional[Callable[[str], None]] = None,
|
|
151
|
+
node_callback: Optional[Callable[[Node], None]] = None,
|
|
145
152
|
):
|
|
146
153
|
"""Initialize the ComfoConnect class.
|
|
147
154
|
|
|
148
|
-
When we received nothing for heartbeat_interval seconds, we ask the bridge for its time, and reconnect when
|
|
149
|
-
doesn't answer. This
|
|
155
|
+
When we sent or received nothing for heartbeat_interval seconds, we ask the bridge for its time, and reconnect when
|
|
156
|
+
it doesn't answer. This keeps the bridge from closing a connection on which we send nothing, and detects a bridge
|
|
157
|
+
that stopped answering without closing the connection. None disables it.
|
|
150
158
|
|
|
151
159
|
The connection_state_callback is called with a ConnectionState when the state of the session changes.
|
|
160
|
+
|
|
161
|
+
The node_callback is called with a Node every time the bridge announces one: at the start of every session, already
|
|
162
|
+
while connect() runs and often more than once, and when a node joins or goes offline (see Node.is_offline).
|
|
152
163
|
"""
|
|
153
|
-
super().__init__(host, uuid
|
|
164
|
+
super().__init__(host, uuid)
|
|
154
165
|
|
|
155
166
|
self.set_sensor_callback(self._sensor_callback) # Set the callback to our _sensor_callback method, so we can proces the callbacks.
|
|
156
167
|
self.set_alarm_callback(self._alarm_callback) # Set the callback to our _alarm_callback method, so we can proces the callbacks.
|
|
168
|
+
self.set_node_callback(node_callback)
|
|
157
169
|
self.sensor_delay = sensor_delay
|
|
158
170
|
self.connect_timeout = connect_timeout
|
|
159
171
|
self.heartbeat_interval = heartbeat_interval
|
|
@@ -285,10 +297,15 @@ class ComfoConnect(Bridge):
|
|
|
285
297
|
_LOGGER.info("Reconnect loop stopped")
|
|
286
298
|
|
|
287
299
|
async def _wait_for_disconnect(self):
|
|
288
|
-
"""Wait until the connection is lost, or until the bridge doesn't answer the heartbeat.
|
|
300
|
+
"""Wait until the connection is lost, or until the bridge doesn't answer the heartbeat.
|
|
301
|
+
|
|
302
|
+
The heartbeat asks the bridge for its time when we sent or received nothing for heartbeat_interval seconds. The
|
|
303
|
+
bridge closes a connection on which we sent nothing for about 90 seconds, also while it pushes sensor values, and a
|
|
304
|
+
bridge that stopped answering doesn't send anything.
|
|
305
|
+
"""
|
|
289
306
|
# The read task ends when the connection is lost. It has already logged why.
|
|
290
307
|
while not self._read_task.done():
|
|
291
|
-
idle = time.monotonic() - self._last_received
|
|
308
|
+
idle = time.monotonic() - min(self._last_sent, self._last_received)
|
|
292
309
|
if self.heartbeat_interval is None or idle < self.heartbeat_interval:
|
|
293
310
|
timeout = None if self.heartbeat_interval is None else self.heartbeat_interval - idle
|
|
294
311
|
await asyncio.wait([self._read_task], timeout=timeout)
|
|
@@ -302,6 +319,18 @@ class ComfoConnect(Bridge):
|
|
|
302
319
|
_LOGGER.warning("The bridge did not answer the heartbeat")
|
|
303
320
|
return
|
|
304
321
|
|
|
322
|
+
@property
|
|
323
|
+
def sensor_values(self) -> Dict[int, Any]:
|
|
324
|
+
"""The latest value of every subscribed sensor, by sensor id, converted like for the sensor callback.
|
|
325
|
+
|
|
326
|
+
A value is None until the bridge sent one. Right after subscribing, it can be the invalid value that the bridge
|
|
327
|
+
sends first, which the sensor callback holds back (see sensor_delay).
|
|
328
|
+
"""
|
|
329
|
+
return {
|
|
330
|
+
sensor_id: None if self._sensors_values.get(sensor_id) is None else _sensor_value(sensor, self._sensors_values[sensor_id])
|
|
331
|
+
for sensor_id, sensor in self._sensors.items()
|
|
332
|
+
}
|
|
333
|
+
|
|
305
334
|
@property
|
|
306
335
|
def connection_state(self) -> str:
|
|
307
336
|
"""The state of the session, one of ConnectionState. Unlike is_connected(), this is only CONNECTED once the session is up."""
|
|
@@ -458,31 +487,36 @@ class ComfoConnect(Bridge):
|
|
|
458
487
|
return values
|
|
459
488
|
|
|
460
489
|
async def get_node_info(self, node_id: Optional[int] = None) -> NodeInfo:
|
|
461
|
-
"""Get the NodeInfo of a node (the ventilation unit by default)
|
|
490
|
+
"""Get the NodeInfo of a node (the ventilation unit by default). A property that the node doesn't have is None.
|
|
462
491
|
|
|
463
|
-
|
|
492
|
+
The properties are read one by one: a node fails a request for several as a whole when it lacks one of them, and
|
|
493
|
+
a ComfoConnect Pro answers it with fewer values than asked. Raises ComfoConnectRmiError when none of the
|
|
494
|
+
properties can be read, e.g. for a node that doesn't exist.
|
|
464
495
|
"""
|
|
465
|
-
props = [PROPERTY_NAME, PROPERTY_MODEL, PROPERTY_ARTICLE, PROPERTY_SERIAL_NUMBER, PROPERTY_FIRMWARE_VERSION, PROPERTY_HARDWARE_VERSION]
|
|
466
|
-
|
|
467
|
-
return NodeInfo(*await self.get_properties(props, node_id))
|
|
468
|
-
except ComfoConnectRmiError as exc:
|
|
469
|
-
error = exc
|
|
496
|
+
props = [PROPERTY_NAME, PROPERTY_MODEL, PROPERTY_ARTICLE, PROPERTY_SERIAL_NUMBER, PROPERTY_FIRMWARE_VERSION, PROPERTY_HARDWARE_VERSION, PROPERTY_PRODUCT_VARIANT]
|
|
497
|
+
errors: List[ComfoConnectRmiError] = []
|
|
470
498
|
|
|
471
|
-
# A request fails as a whole when the node lacks one of the properties, so read them one by one.
|
|
472
499
|
async def get_or_none(prop: Property) -> Any:
|
|
473
500
|
try:
|
|
474
501
|
return await self.get_property(prop, node_id)
|
|
475
|
-
except ComfoConnectRmiError:
|
|
502
|
+
except ComfoConnectRmiError as exc:
|
|
503
|
+
errors.append(exc)
|
|
476
504
|
return None
|
|
477
505
|
|
|
478
506
|
values = [await get_or_none(prop) for prop in props]
|
|
479
|
-
if
|
|
480
|
-
raise
|
|
507
|
+
if len(errors) == len(props):
|
|
508
|
+
raise errors[0]
|
|
481
509
|
return NodeInfo(*values)
|
|
482
510
|
|
|
483
511
|
async def get_single_property(self, unit: int, subunit: int, property_id: int, property_type: int = None, node_id: Optional[int] = None) -> Any:
|
|
484
|
-
"""Get a property and convert to the right type.
|
|
512
|
+
"""Get a property and convert to the right type.
|
|
513
|
+
|
|
514
|
+
Raises ComfoConnectRmiError when the node doesn't have the property: it answers with an RMI error, or, like the
|
|
515
|
+
node of a ComfoConnect Pro, with an empty message.
|
|
516
|
+
"""
|
|
485
517
|
result = await self.cmd_rmi_request(bytes([0x01, unit, subunit, 0x10, property_id]), node_id=node_id)
|
|
518
|
+
if not result.message:
|
|
519
|
+
raise ComfoConnectRmiError(f"The node sent no value for property {property_id}")
|
|
486
520
|
return _decode_value(property_type, result.message)
|
|
487
521
|
|
|
488
522
|
async def get_property_constraints(self, prop: Property, node_id: Optional[int] = None) -> PropertyConstraints:
|
|
@@ -520,9 +554,6 @@ class ComfoConnect(Bridge):
|
|
|
520
554
|
|
|
521
555
|
def _sensor_callback(self, sensor_id, sensor_value):
|
|
522
556
|
"""Callback function for sensor updates."""
|
|
523
|
-
if self._sensor_callback_fn is None:
|
|
524
|
-
return
|
|
525
|
-
|
|
526
557
|
sensor = self._sensors.get(sensor_id)
|
|
527
558
|
if sensor is None:
|
|
528
559
|
# After a quick reconnect, the bridge can still push the sensors of our previous session before we subscribe again.
|
|
@@ -540,11 +571,8 @@ class ComfoConnect(Bridge):
|
|
|
540
571
|
_LOGGER.debug("Got a valid value for sensor %s, releasing the hold", sensor_id)
|
|
541
572
|
self._sensor_holds.pop(sensor_id).cancel()
|
|
542
573
|
|
|
543
|
-
if
|
|
544
|
-
|
|
545
|
-
else:
|
|
546
|
-
val = round(sensor_value, 2)
|
|
547
|
-
self._sensor_callback_fn(sensor, val)
|
|
574
|
+
if self._sensor_callback_fn is not None:
|
|
575
|
+
self._sensor_callback_fn(sensor, _sensor_value(sensor, sensor_value))
|
|
548
576
|
|
|
549
577
|
def _alarm_callback(self, node_id, alarm):
|
|
550
578
|
"""Callback function for alarm updates."""
|
|
@@ -30,16 +30,12 @@ class ProductId:
|
|
|
30
30
|
# nodes on the bus (gateway, connection board, sensors, ...) will reply with RMI_ERROR.
|
|
31
31
|
VENTILATION_UNIT_PRODUCT_IDS = (ProductId.COMFOAIRQ, ProductId.COMFOAIRFLEX)
|
|
32
32
|
|
|
33
|
-
|
|
34
|
-
#
|
|
35
|
-
|
|
36
|
-
"""Defines the type of a bridge, with the values of the GatewayType in the discovery response."""
|
|
37
|
-
|
|
38
|
-
LANC = 0 # ComfoConnect LAN C
|
|
39
|
-
SEASON = 1 # The built-in WiFi module of a ComfoAir Flex
|
|
40
|
-
PRO = 2 # ComfoConnect Pro
|
|
33
|
+
# The product ids of the bridge itself on the bus, in order of preference: a ComfoConnect Pro, a ComfoConnect LAN C,
|
|
34
|
+
# and the WiFi connection module built into a ComfoAir Flex. A Flex with a LAN C would have both of the last two.
|
|
35
|
+
BRIDGE_PRODUCT_IDS = (ProductId.COMFOCONNECTPRO, ProductId.ZEHNDERGATEWAY, ProductId.COMFOAIRFLEXCONNECTIONBOARD)
|
|
41
36
|
|
|
42
37
|
|
|
38
|
+
# PDO Types
|
|
43
39
|
class ConnectionState:
|
|
44
40
|
"""The state of the session with the bridge, as reported to the connection state callback."""
|
|
45
41
|
|
|
@@ -55,12 +51,14 @@ class PdoType:
|
|
|
55
51
|
TYPE_CN_UINT8 = 0x01
|
|
56
52
|
TYPE_CN_UINT16 = 0x02
|
|
57
53
|
TYPE_CN_UINT32 = 0x03
|
|
54
|
+
TYPE_CN_UINT64 = 0x04
|
|
58
55
|
TYPE_CN_INT8 = 0x05
|
|
59
56
|
TYPE_CN_INT16 = 0x06
|
|
57
|
+
TYPE_CN_INT32 = 0x07
|
|
60
58
|
TYPE_CN_INT64 = 0x08
|
|
61
59
|
TYPE_CN_STRING = 0x09
|
|
62
|
-
TYPE_CN_TIME =
|
|
63
|
-
TYPE_CN_VERSION =
|
|
60
|
+
TYPE_CN_TIME = 0x0A
|
|
61
|
+
TYPE_CN_VERSION = 0x0B
|
|
64
62
|
|
|
65
63
|
|
|
66
64
|
# The size in bytes and the signedness of the numeric PDO and property types.
|
|
@@ -68,8 +66,10 @@ NUMERIC_PROPERTY_TYPES = {
|
|
|
68
66
|
PdoType.TYPE_CN_UINT8: (1, False),
|
|
69
67
|
PdoType.TYPE_CN_UINT16: (2, False),
|
|
70
68
|
PdoType.TYPE_CN_UINT32: (4, False),
|
|
69
|
+
PdoType.TYPE_CN_UINT64: (8, False),
|
|
71
70
|
PdoType.TYPE_CN_INT8: (1, True),
|
|
72
71
|
PdoType.TYPE_CN_INT16: (2, True),
|
|
72
|
+
PdoType.TYPE_CN_INT32: (4, True),
|
|
73
73
|
PdoType.TYPE_CN_INT64: (8, True),
|
|
74
74
|
}
|
|
75
75
|
|
|
@@ -49,6 +49,7 @@ class PropertyConstraints:
|
|
|
49
49
|
step: int | float
|
|
50
50
|
|
|
51
51
|
|
|
52
|
+
PROPERTY_PRODUCT_VARIANT = Property(UNIT_NODE, 0x01, 0x03, PdoType.TYPE_CN_UINT8) # E.g. 1=Q350, 2=Q450, 3=Q600 on a ComfoAir Q.
|
|
52
53
|
PROPERTY_SERIAL_NUMBER = Property(UNIT_NODE, 0x01, 0x04, PdoType.TYPE_CN_STRING)
|
|
53
54
|
PROPERTY_HARDWARE_VERSION = Property(UNIT_NODE, 0x01, 0x05, PdoType.TYPE_CN_UINT8)
|
|
54
55
|
PROPERTY_FIRMWARE_VERSION = Property(UNIT_NODE, 0x01, 0x06, PdoType.TYPE_CN_VERSION) # A UINT32, decoded with version_decode().
|
|
@@ -1,6 +1,6 @@
|
|
|
1
1
|
[tool.poetry]
|
|
2
2
|
name = "aiocomfoconnect"
|
|
3
|
-
version = "0.4.
|
|
3
|
+
version = "0.4.5"
|
|
4
4
|
description = "aiocomfoconnect is an asyncio Python 3 library for communicating with a Zehnder ComfoAir Q350/450/600 ventilation system"
|
|
5
5
|
authors = ["Michaël Arnauts <michael.arnauts@gmail.com>"]
|
|
6
6
|
license = "MIT"
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|