aiocomfoconnect 0.4.0__tar.gz → 0.4.2__tar.gz
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- {aiocomfoconnect-0.4.0 → aiocomfoconnect-0.4.2}/PKG-INFO +1 -1
- {aiocomfoconnect-0.4.0 → aiocomfoconnect-0.4.2}/aiocomfoconnect/comfoconnect.py +17 -1
- {aiocomfoconnect-0.4.0 → aiocomfoconnect-0.4.2}/aiocomfoconnect/exceptions.py +9 -1
- {aiocomfoconnect-0.4.0 → aiocomfoconnect-0.4.2}/aiocomfoconnect/sensors.py +21 -1
- {aiocomfoconnect-0.4.0 → aiocomfoconnect-0.4.2}/pyproject.toml +1 -1
- {aiocomfoconnect-0.4.0 → aiocomfoconnect-0.4.2}/LICENSE +0 -0
- {aiocomfoconnect-0.4.0 → aiocomfoconnect-0.4.2}/README.md +0 -0
- {aiocomfoconnect-0.4.0 → aiocomfoconnect-0.4.2}/aiocomfoconnect/__init__.py +0 -0
- {aiocomfoconnect-0.4.0 → aiocomfoconnect-0.4.2}/aiocomfoconnect/__main__.py +0 -0
- {aiocomfoconnect-0.4.0 → aiocomfoconnect-0.4.2}/aiocomfoconnect/bridge.py +0 -0
- {aiocomfoconnect-0.4.0 → aiocomfoconnect-0.4.2}/aiocomfoconnect/const.py +0 -0
- {aiocomfoconnect-0.4.0 → aiocomfoconnect-0.4.2}/aiocomfoconnect/discovery.py +0 -0
- {aiocomfoconnect-0.4.0 → aiocomfoconnect-0.4.2}/aiocomfoconnect/properties.py +0 -0
- {aiocomfoconnect-0.4.0 → aiocomfoconnect-0.4.2}/aiocomfoconnect/protobuf/nanopb_pb2.py +0 -0
- {aiocomfoconnect-0.4.0 → aiocomfoconnect-0.4.2}/aiocomfoconnect/protobuf/zehnder_pb2.py +0 -0
- {aiocomfoconnect-0.4.0 → aiocomfoconnect-0.4.2}/aiocomfoconnect/util.py +0 -0
|
@@ -280,6 +280,21 @@ class ComfoConnect(Bridge):
|
|
|
280
280
|
raise AioComfoConnectNotConnected("Not connected to bridge")
|
|
281
281
|
return super().cmd_rmi_request(message, node_id)
|
|
282
282
|
|
|
283
|
+
async def _send(self, request, request_type, params: dict = None, reply: bool = True, timeout: float = None) -> Message:
|
|
284
|
+
"""Send a request, and close the connection when the bridge dropped our session.
|
|
285
|
+
|
|
286
|
+
The bridge can drop our session without closing the connection, e.g. when another app takes over a session with our
|
|
287
|
+
uuid. It then answers every request with NOT_ALLOWED (or OTHER_SESSION). Closing the connection lets the reconnect
|
|
288
|
+
loop start a new session. The request still raises its error.
|
|
289
|
+
"""
|
|
290
|
+
try:
|
|
291
|
+
return await super()._send(request, request_type, params, reply, timeout)
|
|
292
|
+
except (ComfoConnectNotAllowed, ComfoConnectOtherSession):
|
|
293
|
+
if self._connection_state == ConnectionState.CONNECTED and self._writer is not None:
|
|
294
|
+
_LOGGER.warning("The bridge dropped our session, reconnecting")
|
|
295
|
+
self._writer.close()
|
|
296
|
+
raise
|
|
297
|
+
|
|
283
298
|
async def disconnect(self):
|
|
284
299
|
"""Disconnect from the bridge and stop reconnecting. A connect() that is still busy fails."""
|
|
285
300
|
_LOGGER.debug("Stopping reconnection and disconnecting")
|
|
@@ -418,7 +433,8 @@ class ComfoConnect(Bridge):
|
|
|
418
433
|
|
|
419
434
|
sensor = self._sensors.get(sensor_id)
|
|
420
435
|
if sensor is None:
|
|
421
|
-
|
|
436
|
+
# After a quick reconnect, the bridge can still push the sensors of our previous session before we subscribe again.
|
|
437
|
+
_LOGGER.debug("Ignoring a value for sensor %s, that we are not subscribed to", sensor_id)
|
|
422
438
|
return
|
|
423
439
|
|
|
424
440
|
self._sensors_values[sensor_id] = sensor_value
|
|
@@ -2,6 +2,8 @@
|
|
|
2
2
|
|
|
3
3
|
from __future__ import annotations
|
|
4
4
|
|
|
5
|
+
from .protobuf import zehnder_pb2
|
|
6
|
+
|
|
5
7
|
|
|
6
8
|
class AioComfoConnectError(Exception):
|
|
7
9
|
"""Base class for all errors raised by aiocomfoconnect."""
|
|
@@ -12,7 +14,13 @@ class ComfoConnectError(AioComfoConnectError):
|
|
|
12
14
|
|
|
13
15
|
def __init__(self, message):
|
|
14
16
|
cmd = getattr(message, "cmd", None)
|
|
15
|
-
|
|
17
|
+
if cmd is None:
|
|
18
|
+
text = str(message)
|
|
19
|
+
else:
|
|
20
|
+
result = zehnder_pb2.GatewayOperation.GatewayResult.Name(cmd.result) # pylint: disable=no-member
|
|
21
|
+
description = f": {cmd.resultDescription}" if cmd.resultDescription else ""
|
|
22
|
+
text = f"{result}{description} (reference {cmd.reference})"
|
|
23
|
+
super().__init__(text)
|
|
16
24
|
self.message = message
|
|
17
25
|
|
|
18
26
|
|
|
@@ -66,6 +66,7 @@ SENSOR_POWER_USAGE_TOTAL_YEAR = 129
|
|
|
66
66
|
SENSOR_PREHEATER_POWER = 146
|
|
67
67
|
SENSOR_PREHEATER_POWER_TOTAL = 145
|
|
68
68
|
SENSOR_PREHEATER_POWER_TOTAL_YEAR = 144
|
|
69
|
+
SENSOR_PRESET_TIMERS = 337 # The running timers of the preset schedule, as a bit set: bit 6 is boost, bit 11 is away.
|
|
69
70
|
SENSOR_PROFILE_TEMPERATURE = 67
|
|
70
71
|
SENSOR_RF_PAIRING_MODE = 176
|
|
71
72
|
SENSOR_RMOT = 209
|
|
@@ -81,6 +82,16 @@ SENSOR_UNIT_TEMPERATURE = 208
|
|
|
81
82
|
SENSOR_COMFOCOOL_STATE = 784
|
|
82
83
|
SENSOR_COMFOCOOL_CONDENSOR_TEMP = 802
|
|
83
84
|
|
|
85
|
+
# The CO2 level of the CO2 sensors (ProductId.CO2SENSOR) in zone 1: SENSOR_CO2_1 is the one with the lowest node id.
|
|
86
|
+
SENSOR_CO2_1 = 1024
|
|
87
|
+
SENSOR_CO2_2 = 1025
|
|
88
|
+
SENSOR_CO2_3 = 1026
|
|
89
|
+
SENSOR_CO2_4 = 1027
|
|
90
|
+
SENSOR_CO2_5 = 1028
|
|
91
|
+
SENSOR_CO2_6 = 1029
|
|
92
|
+
SENSOR_CO2_7 = 1030
|
|
93
|
+
SENSOR_CO2_8 = 1031
|
|
94
|
+
|
|
84
95
|
# ComfoClime sensors. These are only reported when a ComfoClime is present on the ComfoNet bus.
|
|
85
96
|
SENSOR_COMFOCLIME_TPMA_TEMPERATURE = 4145
|
|
86
97
|
SENSOR_COMFOCLIME_TARGET_TEMPERATURE = 4148
|
|
@@ -102,6 +113,7 @@ UNIT_CELCIUS = "°C"
|
|
|
102
113
|
UNIT_PERCENT = "%"
|
|
103
114
|
UNIT_RPM = "rpm"
|
|
104
115
|
UNIT_M3H = "m³/h"
|
|
116
|
+
UNIT_PPM = "ppm"
|
|
105
117
|
|
|
106
118
|
|
|
107
119
|
@dataclass
|
|
@@ -184,7 +196,7 @@ SENSORS: Dict[int, Sensor] = {
|
|
|
184
196
|
Sensor("Supply Air Humidity", UNIT_PERCENT, SENSOR_HUMIDITY_SUPPLY, PdoType.TYPE_CN_UINT8),
|
|
185
197
|
Sensor("sensor_321", None, 321, PdoType.TYPE_CN_UINT16),
|
|
186
198
|
Sensor("sensor_325", None, 325, PdoType.TYPE_CN_UINT16),
|
|
187
|
-
Sensor("
|
|
199
|
+
Sensor("Preset Timers", None, SENSOR_PRESET_TIMERS, PdoType.TYPE_CN_UINT32),
|
|
188
200
|
Sensor("Bypass Override", None, SENSOR_BYPASS_OVERRIDE, PdoType.TYPE_CN_UINT32),
|
|
189
201
|
Sensor("sensor_341", None, 341, PdoType.TYPE_CN_UINT32),
|
|
190
202
|
Sensor("Supply Fan Mode (running timers)", None, SENSOR_FAN_MODE_SUPPLY_3, PdoType.TYPE_CN_UINT32),
|
|
@@ -205,6 +217,14 @@ SENSORS: Dict[int, Sensor] = {
|
|
|
205
217
|
Sensor("ComfoCool State", None, SENSOR_COMFOCOOL_STATE, PdoType.TYPE_CN_UINT8),
|
|
206
218
|
Sensor("sensor_785", None, 785, PdoType.TYPE_CN_BOOL, bool),
|
|
207
219
|
Sensor("ComfoCool Condensor Temperature", UNIT_CELCIUS, SENSOR_COMFOCOOL_CONDENSOR_TEMP, PdoType.TYPE_CN_INT16, lambda x: x / 10),
|
|
220
|
+
Sensor("CO2 Sensor 1", UNIT_PPM, SENSOR_CO2_1, PdoType.TYPE_CN_UINT16),
|
|
221
|
+
Sensor("CO2 Sensor 2", UNIT_PPM, SENSOR_CO2_2, PdoType.TYPE_CN_UINT16),
|
|
222
|
+
Sensor("CO2 Sensor 3", UNIT_PPM, SENSOR_CO2_3, PdoType.TYPE_CN_UINT16),
|
|
223
|
+
Sensor("CO2 Sensor 4", UNIT_PPM, SENSOR_CO2_4, PdoType.TYPE_CN_UINT16),
|
|
224
|
+
Sensor("CO2 Sensor 5", UNIT_PPM, SENSOR_CO2_5, PdoType.TYPE_CN_UINT16),
|
|
225
|
+
Sensor("CO2 Sensor 6", UNIT_PPM, SENSOR_CO2_6, PdoType.TYPE_CN_UINT16),
|
|
226
|
+
Sensor("CO2 Sensor 7", UNIT_PPM, SENSOR_CO2_7, PdoType.TYPE_CN_UINT16),
|
|
227
|
+
Sensor("CO2 Sensor 8", UNIT_PPM, SENSOR_CO2_8, PdoType.TYPE_CN_UINT16),
|
|
208
228
|
Sensor("ComfoClime TPMA Temperature", UNIT_CELCIUS, SENSOR_COMFOCLIME_TPMA_TEMPERATURE, PdoType.TYPE_CN_INT16, lambda x: x / 10),
|
|
209
229
|
Sensor("ComfoClime Target Temperature", UNIT_CELCIUS, SENSOR_COMFOCLIME_TARGET_TEMPERATURE, PdoType.TYPE_CN_INT16, lambda x: x / 10),
|
|
210
230
|
Sensor("ComfoClime Device Mode", None, SENSOR_COMFOCLIME_DEVICE_MODE, PdoType.TYPE_CN_UINT8),
|
|
@@ -1,6 +1,6 @@
|
|
|
1
1
|
[tool.poetry]
|
|
2
2
|
name = "aiocomfoconnect"
|
|
3
|
-
version = "0.4.
|
|
3
|
+
version = "0.4.2"
|
|
4
4
|
description = "aiocomfoconnect is an asyncio Python 3 library for communicating with a Zehnder ComfoAir Q350/450/600 ventilation system"
|
|
5
5
|
authors = ["Michaël Arnauts <michael.arnauts@gmail.com>"]
|
|
6
6
|
license = "MIT"
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|