SolixBLE 4.0.0b3__tar.gz → 4.0.0b4__tar.gz

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (54) hide show
  1. {solixble-4.0.0b3 → solixble-4.0.0b4}/PKG-INFO +2 -1
  2. {solixble-4.0.0b3 → solixble-4.0.0b4}/README.md +1 -0
  3. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE/__init__.py +2 -0
  4. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE/devices/__init__.py +6 -4
  5. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE/devices/f2000.py +154 -2
  6. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE/devices/f2600.py +15 -150
  7. solixble-4.0.0b4/SolixBLE/devices/prime_charge_base_150w.py +209 -0
  8. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE/devices/solarbank2.py +15 -3
  9. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE/states.py +97 -2
  10. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE.egg-info/PKG-INFO +2 -1
  11. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE.egg-info/SOURCES.txt +1 -0
  12. {solixble-4.0.0b3 → solixble-4.0.0b4}/pyproject.toml +1 -1
  13. {solixble-4.0.0b3 → solixble-4.0.0b4}/tests/test_commands.py +8 -0
  14. {solixble-4.0.0b3 → solixble-4.0.0b4}/tests/test_devices.py +29 -6
  15. {solixble-4.0.0b3 → solixble-4.0.0b4}/LICENSE.txt +0 -0
  16. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE/advertisement.py +0 -0
  17. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE/const.py +0 -0
  18. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE/constructs.py +0 -0
  19. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE/device.py +0 -0
  20. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE/devices/c1000.py +0 -0
  21. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE/devices/c1000g2.py +0 -0
  22. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE/devices/c300.py +0 -0
  23. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE/devices/c300dc.py +0 -0
  24. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE/devices/c800.py +0 -0
  25. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE/devices/f3800.py +0 -0
  26. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE/devices/generic.py +0 -0
  27. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE/devices/maggo_3in1.py +0 -0
  28. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE/devices/prime_charger_160w.py +0 -0
  29. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE/devices/prime_charger_250w.py +0 -0
  30. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE/devices/prime_power_bank_20k.py +0 -0
  31. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE/devices/solarbank3.py +0 -0
  32. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE/factory.py +0 -0
  33. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE/prime_device.py +0 -0
  34. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE/protocols/__init__.py +0 -0
  35. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE/protocols/base.py +0 -0
  36. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE/protocols/ecdh.py +0 -0
  37. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE/protocols/outer.py +0 -0
  38. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE/protocols/session.py +0 -0
  39. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE/transport.py +0 -0
  40. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE/utilities.py +0 -0
  41. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE.egg-info/dependency_links.txt +0 -0
  42. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE.egg-info/requires.txt +0 -0
  43. {solixble-4.0.0b3 → solixble-4.0.0b4}/SolixBLE.egg-info/top_level.txt +0 -0
  44. {solixble-4.0.0b3 → solixble-4.0.0b4}/setup.cfg +0 -0
  45. {solixble-4.0.0b3 → solixble-4.0.0b4}/tests/test_advertisement.py +0 -0
  46. {solixble-4.0.0b3 → solixble-4.0.0b4}/tests/test_connection.py +0 -0
  47. {solixble-4.0.0b3 → solixble-4.0.0b4}/tests/test_constructs.py +0 -0
  48. {solixble-4.0.0b3 → solixble-4.0.0b4}/tests/test_dynamic_negotiation.py +0 -0
  49. {solixble-4.0.0b3 → solixble-4.0.0b4}/tests/test_factory.py +0 -0
  50. {solixble-4.0.0b3 → solixble-4.0.0b4}/tests/test_prime.py +0 -0
  51. {solixble-4.0.0b3 → solixble-4.0.0b4}/tests/test_protocols.py +0 -0
  52. {solixble-4.0.0b3 → solixble-4.0.0b4}/tests/test_routing.py +0 -0
  53. {solixble-4.0.0b3 → solixble-4.0.0b4}/tests/test_transport.py +0 -0
  54. {solixble-4.0.0b3 → solixble-4.0.0b4}/tests/test_utilities.py +0 -0
@@ -1,6 +1,6 @@
1
1
  Metadata-Version: 2.4
2
2
  Name: SolixBLE
3
- Version: 4.0.0b3
3
+ Version: 4.0.0b4
4
4
  Summary: Python module for monitoring & controlling Bluetooth Anker Solix devices
5
5
  Author-email: Harvey Lelliott <harveylelliott@duck.com>
6
6
  License: MIT License
@@ -105,6 +105,7 @@ See the [support table](https://solixble.readthedocs.io/en/latest) in the docume
105
105
  - F3800
106
106
  - Solarbank 2
107
107
  - Solarbank 3
108
+ - Prime Charge Base 150w
108
109
  - Prime Charger 160w
109
110
  - Prime Charger 250w
110
111
  - Prime MagGo 3in1 (A25X7)
@@ -52,6 +52,7 @@ See the [support table](https://solixble.readthedocs.io/en/latest) in the docume
52
52
  - F3800
53
53
  - Solarbank 2
54
54
  - Solarbank 3
55
+ - Prime Charge Base 150w
55
56
  - Prime Charger 160w
56
57
  - Prime Charger 250w
57
58
  - Prime MagGo 3in1 (A25X7)
@@ -17,6 +17,7 @@ from .devices import (
17
17
  F3800,
18
18
  Generic,
19
19
  MagGo3in1,
20
+ PrimeChargeBase150w,
20
21
  PrimeCharger160w,
21
22
  PrimeCharger250w,
22
23
  PrimePowerBank20k,
@@ -53,6 +54,7 @@ __all__ = [
53
54
  "MagGo3in1",
54
55
  "PortOverload",
55
56
  "PortStatus",
57
+ "PrimeChargeBase150w",
56
58
  "PrimeCharger160w",
57
59
  "PrimeCharger250w",
58
60
  "PrimeDevice",
@@ -14,6 +14,7 @@ from .f2600 import F2600
14
14
  from .f3800 import F3800
15
15
  from .generic import Generic
16
16
  from .maggo_3in1 import MagGo3in1
17
+ from .prime_charge_base_150w import PrimeChargeBase150w
17
18
  from .prime_charger_160w import PrimeCharger160w
18
19
  from .prime_charger_250w import PrimeCharger250w
19
20
  from .prime_power_bank_20k import PrimePowerBank20k
@@ -29,11 +30,12 @@ __all__ = [
29
30
  "F2000",
30
31
  "F2600",
31
32
  "F3800",
32
- "Solarbank2",
33
- "Solarbank3",
33
+ "Generic",
34
+ "MagGo3in1",
35
+ "PrimeChargeBase150w",
34
36
  "PrimeCharger160w",
35
37
  "PrimeCharger250w",
36
38
  "PrimePowerBank20k",
37
- "MagGo3in1",
38
- "Generic",
39
+ "Solarbank2",
40
+ "Solarbank3",
39
41
  ]
@@ -4,14 +4,63 @@
4
4
 
5
5
  """
6
6
 
7
+ import logging
7
8
  from datetime import datetime, timedelta
8
9
 
10
+ from SolixBLE.constructs import ParameterDict, Parameters
11
+
9
12
  from ..const import (
10
13
  DEFAULT_METADATA_FLOAT,
11
14
  DEFAULT_METADATA_INT,
12
15
  DEFAULT_METADATA_STRING,
16
+ TELEMETRY_PATTERN_A,
13
17
  )
14
18
  from ..device import SolixBLEDevice
19
+ from ..states import LightStatus
20
+
21
+ CMD_DISPLAY_ON_OFF = "4052"
22
+ CMD_AC_OUTPUT = "404a"
23
+ CMD_DC_OUTPUT = "404b"
24
+ CMD_POWER_SAVING_MODE = "404e"
25
+ CMD_LIGHT_MODE = "404f"
26
+ CMD_GET_STATUS = "4040"
27
+
28
+ CMD_RESPONSE_GET_STATUS = "c840"
29
+
30
+ PARAMETERS_ON = {
31
+ "a1": {
32
+ "value": "21",
33
+ }, "a2": {
34
+ "type": 1,
35
+ "value": 1,
36
+ },
37
+ }
38
+
39
+ PARAMETERS_OFF = {
40
+ "a1": {
41
+ "value": "21",
42
+ }, "a2": {
43
+ "type": 1,
44
+ "value": 0,
45
+ },
46
+ }
47
+
48
+ PARAMETERS_LIGHT_MODE = {
49
+ "a1": {
50
+ "value": "21",
51
+ }, "a2": {
52
+ "type": 1,
53
+ "value": lambda mode: mode.value,
54
+ },
55
+ }
56
+
57
+ PARAMETERS_GET_STATUS = {
58
+ "a1": {
59
+ "value": "21",
60
+ },
61
+ }
62
+
63
+ _LOGGER = logging.getLogger(__name__)
15
64
 
16
65
 
17
66
  class F2000(SolixBLEDevice):
@@ -22,8 +71,9 @@ class F2000(SolixBLEDevice):
22
71
  This model is also known as the A1780 or the 767 PowerHouse.
23
72
 
24
73
  .. note::
25
- This model was added using data from anker-solix-api. It has not been
26
- tested!
74
+ This model was added using data from anker-solix-api. The commands
75
+ below have been confirmed on real units (see issue #29), but not all
76
+ of the telemetry has been tested.
27
77
 
28
78
  .. note::
29
79
  It should be possible to add more sensors. I think devices with lots of
@@ -282,3 +332,105 @@ class F2000(SolixBLEDevice):
282
332
  :returns: Device serial number or default str value.
283
333
  """
284
334
  return self._parse_string("d0", begin=1)
335
+
336
+ async def turn_ac_on(self) -> None:
337
+ """Turn the AC output on.
338
+
339
+ :raises ConnectionError: If not connected to device.
340
+ :raises BleakError: If command transmission fails.
341
+ """
342
+ await self._send_command(cmd=CMD_AC_OUTPUT, parameters=PARAMETERS_ON)
343
+
344
+ async def turn_ac_off(self) -> None:
345
+ """Turn the AC output off.
346
+
347
+ :raises ConnectionError: If not connected to device.
348
+ :raises BleakError: If command transmission fails.
349
+ """
350
+ await self._send_command(cmd=CMD_AC_OUTPUT, parameters=PARAMETERS_OFF)
351
+
352
+ async def turn_dc_on(self) -> None:
353
+ """Turn the DC output on.
354
+
355
+ :raises ConnectionError: If not connected to device.
356
+ :raises BleakError: If command transmission fails.
357
+ """
358
+ await self._send_command(cmd=CMD_DC_OUTPUT, parameters=PARAMETERS_ON)
359
+
360
+ async def turn_dc_off(self) -> None:
361
+ """Turn the DC output off.
362
+
363
+ :raises ConnectionError: If not connected to device.
364
+ :raises BleakError: If command transmission fails.
365
+ """
366
+ await self._send_command(cmd=CMD_DC_OUTPUT, parameters=PARAMETERS_OFF)
367
+
368
+ async def set_light_mode(self, mode: LightStatus) -> None:
369
+ """Set the light mode of the LED bar.
370
+
371
+ :param mode: Mode to set light bar to.
372
+ :raises ValueError: If requested mode is invalid.
373
+ :raises ConnectionError: If not connected to device.
374
+ :raises BleakError: If command transmission fails.
375
+ """
376
+ if mode is LightStatus.UNKNOWN:
377
+ raise ValueError("You cannot set the light status to unknown")
378
+ await self._send_command(
379
+ cmd=CMD_LIGHT_MODE,
380
+ parameters=PARAMETERS_LIGHT_MODE,
381
+ mode=mode,
382
+ )
383
+
384
+ async def turn_display_on(self) -> None:
385
+ """Turn the display on.
386
+
387
+ :raises ConnectionError: If not connected to device.
388
+ :raises BleakError: If command transmission fails.
389
+ """
390
+ await self._send_command(cmd=CMD_DISPLAY_ON_OFF, parameters=PARAMETERS_ON)
391
+
392
+ async def turn_display_off(self) -> None:
393
+ """Turn the display off.
394
+
395
+ :raises ConnectionError: If not connected to device.
396
+ :raises BleakError: If command transmission fails.
397
+ """
398
+ await self._send_command(cmd=CMD_DISPLAY_ON_OFF, parameters=PARAMETERS_OFF)
399
+
400
+ async def turn_power_saving_mode_on(self) -> None:
401
+ """Turn the power saving mode on.
402
+
403
+ :raises ConnectionError: If not connected to device.
404
+ :raises BleakError: If command transmission fails.
405
+ """
406
+ await self._send_command(cmd=CMD_POWER_SAVING_MODE, parameters=PARAMETERS_ON)
407
+
408
+ async def turn_power_saving_mode_off(self) -> None:
409
+ """Turn the power saving mode off.
410
+
411
+ :raises ConnectionError: If not connected to device.
412
+ :raises BleakError: If command transmission fails.
413
+ """
414
+ await self._send_command(cmd=CMD_POWER_SAVING_MODE, parameters=PARAMETERS_OFF)
415
+
416
+ async def get_status_update(self) -> ParameterDict:
417
+ """Request and retrieve a status update from the device.
418
+
419
+ :raises ConnectionError: If not connected to device.
420
+ :raises TimeoutError: If no response from device.
421
+ :raises BleakError: If command transmission fails.
422
+ :returns: Dictionary containing telemetry parameters.
423
+ """
424
+ await self._send_command(cmd=CMD_GET_STATUS, parameters=PARAMETERS_GET_STATUS)
425
+ payload = await self._listen_for_packet(
426
+ bytes.fromhex(TELEMETRY_PATTERN_A), bytes.fromhex(CMD_RESPONSE_GET_STATUS),
427
+ )
428
+ if not payload:
429
+ raise TimeoutError("Timed out waiting for payload!")
430
+
431
+ parameters = Parameters.parse(payload)
432
+ _LOGGER.debug(f"Parameters: {parameters}")
433
+ await self._process_telemetry(
434
+ parameters,
435
+ ) # update the internal parameters as well
436
+ return parameters
@@ -5,59 +5,35 @@
5
5
 
6
6
  """
7
7
 
8
- import logging
9
8
  from datetime import datetime, timedelta
10
9
 
11
- from SolixBLE.constructs import ParameterDict, Parameters
12
-
13
10
  from ..const import (
14
11
  DEFAULT_METADATA_BOOL,
15
12
  DEFAULT_METADATA_INT,
16
- TELEMETRY_PATTERN_A,
17
13
  )
18
14
  from ..states import ChargingStatus, DisplayTimeout, LightStatus, PortStatus
19
15
  from . import F2000
20
16
 
17
+ # The commands the F2000 shares now live there. They stay importable from here.
18
+ from .f2000 import (
19
+ CMD_AC_OUTPUT as CMD_AC_OUTPUT,
20
+ CMD_DC_OUTPUT as CMD_DC_OUTPUT,
21
+ CMD_DISPLAY_ON_OFF as CMD_DISPLAY_ON_OFF,
22
+ CMD_GET_STATUS as CMD_GET_STATUS,
23
+ CMD_LIGHT_MODE as CMD_LIGHT_MODE,
24
+ CMD_POWER_SAVING_MODE as CMD_POWER_SAVING_MODE,
25
+ CMD_RESPONSE_GET_STATUS as CMD_RESPONSE_GET_STATUS,
26
+ PARAMETERS_GET_STATUS as PARAMETERS_GET_STATUS,
27
+ PARAMETERS_LIGHT_MODE,
28
+ PARAMETERS_OFF as PARAMETERS_OFF,
29
+ PARAMETERS_ON as PARAMETERS_ON,
30
+ )
31
+
21
32
  CMD_AC_TIMER = "4042"
22
33
  CMD_DC_TIMER = "4043"
23
34
  CMD_AC_CHARGING_POWER = "4044"
24
35
  CMD_DISPLAY_TIMEOUT = "4046"
25
- CMD_DISPLAY_ON_OFF = "4052"
26
- CMD_AC_OUTPUT = "404a"
27
- CMD_DC_OUTPUT = "404b"
28
36
  CMD_DISPLAY_MODE = "404c"
29
- CMD_POWER_SAVING_MODE = "404e"
30
- CMD_LIGHT_MODE = "404f"
31
- CMD_GET_STATUS = "4040"
32
-
33
- CMD_RESPONSE_GET_STATUS = "c840"
34
-
35
- PARAMETERS_ON = {
36
- "a1": {
37
- "value": "21",
38
- }, "a2": {
39
- "type": 1,
40
- "value": 1,
41
- },
42
- }
43
-
44
- PARAMETERS_OFF = {
45
- "a1": {
46
- "value": "21",
47
- }, "a2": {
48
- "type": 1,
49
- "value": 0,
50
- },
51
- }
52
-
53
- PARAMETERS_LIGHT_MODE = {
54
- "a1": {
55
- "value": "21",
56
- }, "a2": {
57
- "type": 1,
58
- "value": lambda mode: mode.value,
59
- },
60
- }
61
37
 
62
38
  PARAMETERS_TIMEOUT_TIME = {
63
39
  "a1": {
@@ -98,15 +74,6 @@ PARAMETERS_TIMER = {
98
74
  },
99
75
  }
100
76
 
101
- PARAMETERS_GET_STATUS = {
102
- "a1": {
103
- "value": "21",
104
- },
105
- }
106
-
107
- _LOGGER = logging.getLogger(__name__)
108
-
109
-
110
77
  class F2600(F2000):
111
78
  """
112
79
  F2600 Power Station.
@@ -359,38 +326,6 @@ class F2600(F2000):
359
326
  return LightStatus.UNKNOWN
360
327
  return LightStatus(self._parse_int("d9", begin=1))
361
328
 
362
- async def turn_ac_on(self) -> None:
363
- """Turn the AC output on.
364
-
365
- :raises ConnectionError: If not connected to device.
366
- :raises BleakError: If command transmission fails.
367
- """
368
- await self._send_command(cmd=CMD_AC_OUTPUT, parameters=PARAMETERS_ON)
369
-
370
- async def turn_ac_off(self) -> None:
371
- """Turn the AC output off.
372
-
373
- :raises ConnectionError: If not connected to device.
374
- :raises BleakError: If command transmission fails.
375
- """
376
- await self._send_command(cmd=CMD_AC_OUTPUT, parameters=PARAMETERS_OFF)
377
-
378
- async def turn_dc_on(self) -> None:
379
- """Turn the DC output on.
380
-
381
- :raises ConnectionError: If not connected to device.
382
- :raises BleakError: If command transmission fails.
383
- """
384
- await self._send_command(cmd=CMD_DC_OUTPUT, parameters=PARAMETERS_ON)
385
-
386
- async def turn_dc_off(self) -> None:
387
- """Turn the DC output off.
388
-
389
- :raises ConnectionError: If not connected to device.
390
- :raises BleakError: If command transmission fails.
391
- """
392
- await self._send_command(cmd=CMD_DC_OUTPUT, parameters=PARAMETERS_OFF)
393
-
394
329
  async def set_ac_timer(self, seconds: int) -> None:
395
330
  """Set the AC auto-off timer.
396
331
 
@@ -417,22 +352,6 @@ class F2600(F2000):
417
352
  seconds=seconds,
418
353
  )
419
354
 
420
- async def set_light_mode(self, mode: LightStatus) -> None:
421
- """Set the light mode of the LED bar.
422
-
423
- :param mode: Mode to set light bar to.
424
- :raises ValueError: If requested mode is invalid.
425
- :raises ConnectionError: If not connected to device.
426
- :raises BleakError: If command transmission fails.
427
- """
428
- if mode is LightStatus.UNKNOWN:
429
- raise ValueError("You cannot set the light status to unknown")
430
- await self._send_command(
431
- cmd=CMD_LIGHT_MODE,
432
- parameters=PARAMETERS_LIGHT_MODE,
433
- mode=mode,
434
- )
435
-
436
355
  async def set_display_mode(self, mode: LightStatus) -> None:
437
356
  """Set the status/mode of the LCD display.
438
357
 
@@ -468,38 +387,6 @@ class F2600(F2000):
468
387
  time=timeout,
469
388
  )
470
389
 
471
- async def turn_display_on(self) -> None:
472
- """Turn the display on.
473
-
474
- :raises ConnectionError: If not connected to device.
475
- :raises BleakError: If command transmission fails.
476
- """
477
- await self._send_command(cmd=CMD_DISPLAY_ON_OFF, parameters=PARAMETERS_ON)
478
-
479
- async def turn_display_off(self) -> None:
480
- """Turn the display off.
481
-
482
- :raises ConnectionError: If not connected to device.
483
- :raises BleakError: If command transmission fails.
484
- """
485
- await self._send_command(cmd=CMD_DISPLAY_ON_OFF, parameters=PARAMETERS_OFF)
486
-
487
- async def turn_power_saving_mode_on(self) -> None:
488
- """Turn the power saving mode on.
489
-
490
- :raises ConnectionError: If not connected to device.
491
- :raises BleakError: If command transmission fails.
492
- """
493
- await self._send_command(cmd=CMD_POWER_SAVING_MODE, parameters=PARAMETERS_ON)
494
-
495
- async def turn_power_saving_mode_off(self) -> None:
496
- """Turn the power saving mode off.
497
-
498
- :raises ConnectionError: If not connected to device.
499
- :raises BleakError: If command transmission fails.
500
- """
501
- await self._send_command(cmd=CMD_POWER_SAVING_MODE, parameters=PARAMETERS_OFF)
502
-
503
390
  async def set_ac_charging_power(self, watts: int) -> None:
504
391
  """Set the AC charging power limit in watts.
505
392
 
@@ -518,25 +405,3 @@ class F2600(F2000):
518
405
  parameters=PARAMETERS_CHARGE_POWER,
519
406
  watts=watts,
520
407
  )
521
-
522
- async def get_status_update(self) -> ParameterDict:
523
- """Request and retrieve a status update from the device.
524
-
525
- :raises ConnectionError: If not connected to device.
526
- :raises TimeoutError: If no response from device.
527
- :raises BleakError: If command transmission fails.
528
- :returns: Dictionary containing telemetry parameters.
529
- """
530
- await self._send_command(cmd=CMD_GET_STATUS, parameters=PARAMETERS_GET_STATUS)
531
- payload = await self._listen_for_packet(
532
- bytes.fromhex(TELEMETRY_PATTERN_A), bytes.fromhex(CMD_RESPONSE_GET_STATUS),
533
- )
534
- if not payload:
535
- raise TimeoutError("Timed out waiting for payload!")
536
-
537
- parameters = Parameters.parse(payload)
538
- _LOGGER.debug(f"Parameters: {parameters}")
539
- await self._process_telemetry(
540
- parameters,
541
- ) # update the internal parameters as well
542
- return parameters
@@ -0,0 +1,209 @@
1
+ """Anker Prime Charging Base (150w) model.
2
+
3
+ .. moduleauthor:: Harvey Lelliott (flip-dots) <harveylelliott@duck.com>
4
+
5
+ """
6
+
7
+ from ..const import DEFAULT_METADATA_FLOAT
8
+ from ..prime_device import PrimeDevice
9
+ from ..states import PortStatus
10
+
11
+ #: Command sent after connecting to start the telemetry stream. This must
12
+ #: be sent every ~10 seconds or no telemetry will be sent by the device.
13
+ CMD_SUB_AND_KEEP_ALIVE = "420b"
14
+ PARAMETERS_KEEP_ALIVE = {
15
+ "a1": {
16
+ "value": "21",
17
+ },
18
+ }
19
+ KEEP_ALIVE_INTERNAL = 10
20
+
21
+
22
+ class PrimeChargeBase150w(PrimeDevice):
23
+ """
24
+ Anker Prime Charge Base (150w) model.
25
+
26
+ Use this class to connect and monitor the 150w charge base.
27
+ This model is also known as the A1903.
28
+ """
29
+
30
+ _TELEMETRY_COMMANDS = ("4303",)
31
+
32
+ async def _keep_alive(self) -> int | None:
33
+ await self._send_command(
34
+ cmd=CMD_SUB_AND_KEEP_ALIVE,
35
+ parameters=PARAMETERS_KEEP_ALIVE,
36
+ )
37
+ return KEEP_ALIVE_INTERNAL
38
+
39
+ @property
40
+ def usb_port_c1(self) -> PortStatus:
41
+ """USB C1 Port Status.
42
+
43
+ :returns: Status of the USB C1 port.
44
+ """
45
+ return PortStatus(self._parse_int("a2", begin=1, end=2))
46
+
47
+ @property
48
+ def usb_c1_voltage(self) -> float:
49
+ """USB C1 Port voltage (V).
50
+
51
+ :returns: Voltage of the USB C1 port or default float value.
52
+ """
53
+ if self._data is None:
54
+ return DEFAULT_METADATA_FLOAT
55
+
56
+ return self._parse_int("a2", begin=2, end=4) / 10.0
57
+
58
+ @property
59
+ def usb_c1_current(self) -> float:
60
+ """USB C1 Port current (A).
61
+
62
+ :returns: Current of the USB C1 port or default float value.
63
+ """
64
+ if self._data is None:
65
+ return DEFAULT_METADATA_FLOAT
66
+
67
+ return self._parse_int("a2", begin=4, end=6) / 10.0
68
+
69
+ @property
70
+ def usb_c1_power(self) -> float:
71
+ """USB C1 Port power (W).
72
+
73
+ :returns: Power of the USB C1 port or default float value.
74
+ """
75
+ if self._data is None:
76
+ return DEFAULT_METADATA_FLOAT
77
+
78
+ return self._parse_int("a2", begin=6, end=8) / 10.0
79
+
80
+ @property
81
+ def usb_port_c2(self) -> PortStatus:
82
+ """USB C2 Port Status.
83
+
84
+ :returns: Status of the USB C2 port.
85
+ """
86
+ return PortStatus(self._parse_int("a3", begin=1, end=2))
87
+
88
+ @property
89
+ def usb_c2_voltage(self) -> float:
90
+ """USB C2 Port voltage (V).
91
+
92
+ :returns: Voltage of the USB C2 port or default float value.
93
+ """
94
+ if self._data is None:
95
+ return DEFAULT_METADATA_FLOAT
96
+
97
+ return self._parse_int("a3", begin=2, end=4) / 10.0
98
+
99
+ @property
100
+ def usb_c2_current(self) -> float:
101
+ """USB C2 Port current (A).
102
+
103
+ :returns: Current of the USB C2 port or default float value.
104
+ """
105
+ if self._data is None:
106
+ return DEFAULT_METADATA_FLOAT
107
+
108
+ return self._parse_int("a3", begin=4, end=6) / 10.0
109
+
110
+ @property
111
+ def usb_c2_power(self) -> float:
112
+ """USB C2 Port power (W).
113
+
114
+ :returns: Power of the USB C2 port or default float value.
115
+ """
116
+ if self._data is None:
117
+ return DEFAULT_METADATA_FLOAT
118
+
119
+ return self._parse_int("a3", begin=6, end=8) / 10.0
120
+
121
+ @property
122
+ def usb_port_a1(self) -> PortStatus:
123
+ """USB A1 Port Status.
124
+
125
+ :returns: Status of the USB A1 port.
126
+ """
127
+ return PortStatus(self._parse_int("a4", begin=1, end=2))
128
+
129
+ @property
130
+ def usb_a1_voltage(self) -> float:
131
+ """USB A1 Port voltage (V).
132
+
133
+ :returns: Voltage of the USB A1 port or default float value.
134
+ """
135
+ if self._data is None:
136
+ return DEFAULT_METADATA_FLOAT
137
+
138
+ return self._parse_int("a4", begin=2, end=4) / 10.0
139
+
140
+ @property
141
+ def usb_a1_current(self) -> float:
142
+ """USB A1 Port current (A).
143
+
144
+ :returns: Current of the USB A1 port or default float value.
145
+ """
146
+ if self._data is None:
147
+ return DEFAULT_METADATA_FLOAT
148
+
149
+ return self._parse_int("a4", begin=4, end=6) / 10.0
150
+
151
+ @property
152
+ def usb_a1_power(self) -> float:
153
+ """USB A1 Port power (W).
154
+
155
+ :returns: Power of the USB A1 port or default float value.
156
+ """
157
+ if self._data is None:
158
+ return DEFAULT_METADATA_FLOAT
159
+
160
+ return self._parse_int("a4", begin=6, end=8) / 10.0
161
+
162
+ @property
163
+ def dock_status(self) -> PortStatus:
164
+ """Power Bank Dock Port Status.
165
+
166
+ :returns: Status of the power bank charging port.
167
+ """
168
+ return PortStatus(self._parse_int("a5", begin=1, end=2))
169
+
170
+ @property
171
+ def dock_voltage(self) -> float:
172
+ """Power Bank Dock Port voltage (V).
173
+
174
+ :returns: Voltage of the power bank charging port or default float value.
175
+ """
176
+ if self._data is None:
177
+ return DEFAULT_METADATA_FLOAT
178
+
179
+ return self._parse_int("a5", begin=2, end=4) / 10.0
180
+
181
+ @property
182
+ def dock_current(self) -> float:
183
+ """Power Bank Dock Port Current (A).
184
+
185
+ :returns: Current of the power bank charging port or default float value.
186
+ """
187
+ if self._data is None:
188
+ return DEFAULT_METADATA_FLOAT
189
+
190
+ return self._parse_int("a5", begin=4, end=6) / 10.0
191
+
192
+ @property
193
+ def dock_power(self) -> float:
194
+ """Power Bank Dock Port Power (W).
195
+
196
+ :returns: Power of the power bank charging port or default float value.
197
+ """
198
+ if self._data is None:
199
+ return DEFAULT_METADATA_FLOAT
200
+
201
+ return self._parse_int("a5", begin=6, end=8) / 10.0
202
+
203
+ @property
204
+ def power_out(self) -> float:
205
+ """Total Power Out.
206
+
207
+ :returns: Total power out or default float value.
208
+ """
209
+ return self._parse_int("a6", begin=1, end=3) / 10.0
@@ -4,6 +4,9 @@
4
4
 
5
5
  """
6
6
 
7
+ from __future__ import annotations
8
+
9
+ import logging
7
10
  from enum import Enum
8
11
 
9
12
  from ..const import (
@@ -14,11 +17,13 @@ from ..const import (
14
17
  from ..device import SolixBLEDevice
15
18
  from ..states import GridStatus, LightMode, SBPowerCutoff, SBUsageMode, TemperatureUnit
16
19
 
20
+ _LOGGER = logging.getLogger(__name__)
21
+
17
22
 
18
23
  class MaxLoadSB2(Enum):
19
24
  """
20
25
  Maximum output power of the Solarbank 2 in watts.
21
-
26
+
22
27
  Only specific values are allowed.
23
28
  """
24
29
 
@@ -37,6 +42,14 @@ class MaxLoadSB2(Enum):
37
42
  #: 1000 watts.
38
43
  W1000 = 1000
39
44
 
45
+ @classmethod
46
+ def _missing_(cls, value: object) -> MaxLoadSB2:
47
+ """Return the unknown value if the value is not recognized."""
48
+ _LOGGER.warning(
49
+ f"Unexpected max load '{value}'. Returning MaxLoadSB2.UNKNOWN",
50
+ )
51
+ return cls.UNKNOWN
52
+
40
53
 
41
54
  class Solarbank2(SolixBLEDevice):
42
55
  """
@@ -381,7 +394,7 @@ class Solarbank2(SolixBLEDevice):
381
394
  def max_load(self) -> MaxLoadSB2:
382
395
  """
383
396
  Maximum output power in watts.
384
-
397
+
385
398
  Maximum legal value depends on country of operation.
386
399
 
387
400
  :returns: Maximum load as a MaxLoadSB2 enum value.
@@ -444,4 +457,3 @@ class Solarbank2(SolixBLEDevice):
444
457
  if self._data is not None
445
458
  else DEFAULT_METADATA_BOOL
446
459
  )
447
-
@@ -4,8 +4,13 @@
4
4
 
5
5
  """
6
6
 
7
+ from __future__ import annotations
8
+
9
+ import logging
7
10
  from enum import Enum
8
11
 
12
+ _LOGGER = logging.getLogger(__name__)
13
+
9
14
 
10
15
  class PortStatus(Enum):
11
16
  """The status of a port on the device."""
@@ -23,8 +28,8 @@ class PortStatus(Enum):
23
28
  INPUT = 2
24
29
 
25
30
  @classmethod
26
- def from_input_only(cls, value: int):
27
- """Custom factory for ports which only support being inputs."""
31
+ def from_input_only(cls, value: int) -> PortStatus:
32
+ """PortStatus factory for input only port."""
28
33
 
29
34
  # If it would be an output (i.e 1) set it to input (i.e 2).
30
35
  if value == PortStatus.OUTPUT.value:
@@ -32,6 +37,14 @@ class PortStatus(Enum):
32
37
 
33
38
  return cls(value)
34
39
 
40
+ @classmethod
41
+ def _missing_(cls, value: object) -> PortStatus:
42
+ """Return the unknown value if the value is not recognized."""
43
+ _LOGGER.warning(
44
+ f"Unexpected port status '{value}'. Returning PortStatus.UNKNOWN",
45
+ )
46
+ return cls.UNKNOWN
47
+
35
48
 
36
49
  class ChargingStatus(Enum):
37
50
  """The status of charging/discharging on a device."""
@@ -48,6 +61,14 @@ class ChargingStatus(Enum):
48
61
  #: The device is charging.
49
62
  CHARGING = 2
50
63
 
64
+ @classmethod
65
+ def _missing_(cls, value: object) -> ChargingStatus:
66
+ """Return the unknown value if the value is not recognized."""
67
+ _LOGGER.warning(
68
+ f"Unexpected charging status '{value}'. Returning ChargingStatus.UNKNOWN",
69
+ )
70
+ return cls.UNKNOWN
71
+
51
72
 
52
73
  class ChargingStatusF3800(Enum):
53
74
  """The charging type of an F3800."""
@@ -67,6 +88,14 @@ class ChargingStatusF3800(Enum):
67
88
  #: The device is charging via solar and AC.
68
89
  BOTH = 3
69
90
 
91
+ @classmethod
92
+ def _missing_(cls, value: object) -> ChargingStatusF3800:
93
+ """Return the unknown value if the value is not recognized."""
94
+ _LOGGER.warning(
95
+ f"Unexpected charging status '{value}'. Returning ChargingStatusF3800.UNKNOWN", # noqa: E501
96
+ )
97
+ return cls.UNKNOWN
98
+
70
99
 
71
100
  class LightStatus(Enum):
72
101
  """The status of the light on the device."""
@@ -89,6 +118,14 @@ class LightStatus(Enum):
89
118
  #: SOS mode. Not supported by all devices.
90
119
  SOS = 4
91
120
 
121
+ @classmethod
122
+ def _missing_(cls, value: object) -> LightStatus:
123
+ """Return the unknown value if the value is not recognized."""
124
+ _LOGGER.warning(
125
+ f"Unexpected light status '{value}'. Returning LightStatus.UNKNOWN",
126
+ )
127
+ return cls.UNKNOWN
128
+
92
129
 
93
130
  class LightMode(Enum):
94
131
  """The light mode of the device."""
@@ -102,6 +139,14 @@ class LightMode(Enum):
102
139
  #: Mood light mode.
103
140
  MOOD = 1
104
141
 
142
+ @classmethod
143
+ def _missing_(cls, value: object) -> LightMode:
144
+ """Return the unknown value if the value is not recognized."""
145
+ _LOGGER.warning(
146
+ f"Unexpected light mode '{value}'. Returning LightMode.UNKNOWN",
147
+ )
148
+ return cls.UNKNOWN
149
+
105
150
 
106
151
  class DisplayTimeout(Enum):
107
152
  """Display timeout on device in seconds. Only specific values are allowed."""
@@ -124,6 +169,15 @@ class DisplayTimeout(Enum):
124
169
  #: 1800 seconds (30m).
125
170
  S1800 = 1800
126
171
 
172
+ @classmethod
173
+ def _missing_(cls, value: object) -> DisplayTimeout:
174
+ """Return the unknown value if the value is not recognized."""
175
+ _LOGGER.warning(
176
+ f"Unexpected display timeout '{value}'. Returning DisplayTimeout.UNKNOWN",
177
+ )
178
+ return cls.UNKNOWN
179
+
180
+
127
181
  class TemperatureUnit(Enum):
128
182
  """The status of the temperature unit of the device."""
129
183
 
@@ -136,6 +190,15 @@ class TemperatureUnit(Enum):
136
190
  #: Display unit is Fahrenheit.
137
191
  FAHRENHEIT = 1
138
192
 
193
+ @classmethod
194
+ def _missing_(cls, value: object) -> TemperatureUnit:
195
+ """Return the unknown value if the value is not recognized."""
196
+ _LOGGER.warning(
197
+ f"Unexpected temperature unit '{value}'. Returning TemperatureUnit.UNKNOWN",
198
+ )
199
+ return cls.UNKNOWN
200
+
201
+
139
202
  class GridStatus(Enum):
140
203
  """The grid connection status."""
141
204
 
@@ -156,6 +219,14 @@ class GridStatus(Enum):
156
219
  #: No grid connection.
157
220
  NO_GRID = 6
158
221
 
222
+ @classmethod
223
+ def _missing_(cls, value: object) -> GridStatus:
224
+ """Return the unknown value if the value is not recognized."""
225
+ _LOGGER.warning(
226
+ f"Unexpected grid status '{value}'. Returning GridStatus.UNKNOWN",
227
+ )
228
+ return cls.UNKNOWN
229
+
159
230
 
160
231
  class SBUsageMode(Enum):
161
232
  """Usage mode of a Solarbank device."""
@@ -184,6 +255,14 @@ class SBUsageMode(Enum):
184
255
  #: Time slot mode.
185
256
  TIME_SLOT = 8
186
257
 
258
+ @classmethod
259
+ def _missing_(cls, value: object) -> SBUsageMode:
260
+ """Return the unknown value if the value is not recognized."""
261
+ _LOGGER.warning(
262
+ f"Unexpected SB usage mode '{value}'. Returning SBUsageMode.UNKNOWN",
263
+ )
264
+ return cls.UNKNOWN
265
+
187
266
 
188
267
  class SBPowerCutoff(Enum):
189
268
  """Power cutoff threshold of a Solarbank device in %."""
@@ -197,6 +276,14 @@ class SBPowerCutoff(Enum):
197
276
  #: 10 %.
198
277
  P10 = 10
199
278
 
279
+ @classmethod
280
+ def _missing_(cls, value: object) -> SBPowerCutoff:
281
+ """Return the unknown value if the value is not recognized."""
282
+ _LOGGER.warning(
283
+ f"Unexpected SB cutoff '{value}'. Returning SBPowerCutoff.UNKNOWN",
284
+ )
285
+ return cls.UNKNOWN
286
+
200
287
 
201
288
  class PortOverload(Enum):
202
289
  """The overload status of a port."""
@@ -215,3 +302,11 @@ class PortOverload(Enum):
215
302
 
216
303
  #: USB C3 overload detected.
217
304
  USB_C3 = 10
305
+
306
+ @classmethod
307
+ def _missing_(cls, value: object) -> PortOverload:
308
+ """Return the unknown value if the value is not recognized."""
309
+ _LOGGER.warning(
310
+ f"Unexpected port overload '{value}'. Returning PortOverload.UNKNOWN",
311
+ )
312
+ return cls.UNKNOWN
@@ -1,6 +1,6 @@
1
1
  Metadata-Version: 2.4
2
2
  Name: SolixBLE
3
- Version: 4.0.0b3
3
+ Version: 4.0.0b4
4
4
  Summary: Python module for monitoring & controlling Bluetooth Anker Solix devices
5
5
  Author-email: Harvey Lelliott <harveylelliott@duck.com>
6
6
  License: MIT License
@@ -105,6 +105,7 @@ See the [support table](https://solixble.readthedocs.io/en/latest) in the docume
105
105
  - F3800
106
106
  - Solarbank 2
107
107
  - Solarbank 3
108
+ - Prime Charge Base 150w
108
109
  - Prime Charger 160w
109
110
  - Prime Charger 250w
110
111
  - Prime MagGo 3in1 (A25X7)
@@ -27,6 +27,7 @@ SolixBLE/devices/f2600.py
27
27
  SolixBLE/devices/f3800.py
28
28
  SolixBLE/devices/generic.py
29
29
  SolixBLE/devices/maggo_3in1.py
30
+ SolixBLE/devices/prime_charge_base_150w.py
30
31
  SolixBLE/devices/prime_charger_160w.py
31
32
  SolixBLE/devices/prime_charger_250w.py
32
33
  SolixBLE/devices/prime_power_bank_20k.py
@@ -1,6 +1,6 @@
1
1
  [project]
2
2
  name = "SolixBLE"
3
- version = "4.0.0b3"
3
+ version = "4.0.0b4"
4
4
  dependencies = [
5
5
  "bleak>=0.19.0",
6
6
  "cryptography",
@@ -29,6 +29,11 @@ from tests.devices.c1000 import (
29
29
  C1000_TEST_COMMANDS_RESPONSES,
30
30
  )
31
31
  from tests.devices.c1000g2 import C1000G2_TEST_COMMANDS, C1000G2_TEST_COMMANDS_E2E
32
+ from tests.devices.f2000 import (
33
+ F2000_TEST_COMMANDS,
34
+ F2000_TEST_COMMANDS_E2E,
35
+ F2000_TEST_COMMANDS_RESPONSES,
36
+ )
32
37
  from tests.devices.f2600 import (
33
38
  F2600_TEST_COMMANDS,
34
39
  F2600_TEST_COMMANDS_E2E,
@@ -55,6 +60,7 @@ from tests.helpers import MockDevice
55
60
  *C800_TEST_COMMANDS,
56
61
  *C1000_TEST_COMMANDS,
57
62
  *C1000G2_TEST_COMMANDS,
63
+ *F2000_TEST_COMMANDS,
58
64
  *F2600_TEST_COMMANDS,
59
65
  *F3800_TEST_COMMANDS,
60
66
  *PRIME_CHARGER_160W_TEST_COMMANDS,
@@ -107,6 +113,7 @@ async def test_send_command(
107
113
  *C300_TEST_COMMANDS_RESPONSES,
108
114
  *C800_TEST_COMMANDS_RESPONSES,
109
115
  *C1000_TEST_COMMANDS_RESPONSES,
116
+ *F2000_TEST_COMMANDS_RESPONSES,
110
117
  *F2600_TEST_COMMANDS_RESPONSES,
111
118
  ],
112
119
  )
@@ -176,6 +183,7 @@ async def test_send_command_response( # noqa: PLR0913, PLR0917
176
183
  *C800_TEST_COMMANDS_E2E,
177
184
  *C1000_TEST_COMMANDS_E2E,
178
185
  *C1000G2_TEST_COMMANDS_E2E,
186
+ *F2000_TEST_COMMANDS_E2E,
179
187
  *F2600_TEST_COMMANDS_E2E,
180
188
  *F3800_TEST_COMMANDS_E2E,
181
189
  *PRIME_CHARGER_160W_TEST_COMMANDS_E2E,
@@ -23,6 +23,7 @@ from SolixBLE import (
23
23
  MagGo3in1,
24
24
  PortOverload,
25
25
  PortStatus,
26
+ PrimeChargeBase150w,
26
27
  PrimeCharger160w,
27
28
  PrimeCharger250w,
28
29
  PrimeDevice,
@@ -1007,6 +1008,31 @@ from tests.helpers import MockDevice, install_session_keys
1007
1008
  },
1008
1009
  id="f2600_solar_discharging",
1009
1010
  ),
1011
+ # Anker Prime Charging Base 150w
1012
+ pytest.param(
1013
+ PrimeChargeBase150w,
1014
+ "a10131a20e04015d001800df000008ffffffffa30e0401320001000500ff00ffffffffa409040132000100050000a5080401d3002400f702a60302e003fe05033bfb0b6b",
1015
+ {
1016
+ "usb_port_c1": PortStatus.OUTPUT,
1017
+ "usb_c1_current": 2.4,
1018
+ "usb_c1_power": 22.3,
1019
+ "usb_c1_voltage": 9.3,
1020
+ "usb_port_c2": PortStatus.OUTPUT,
1021
+ "usb_c2_current": 0.1,
1022
+ "usb_c2_power": 0.5,
1023
+ "usb_c2_voltage": 5.0,
1024
+ "usb_port_a1": PortStatus.OUTPUT,
1025
+ "usb_a1_current": 0.1,
1026
+ "usb_a1_power": 0.5,
1027
+ "usb_a1_voltage": 5.0,
1028
+ "dock_status": PortStatus.OUTPUT,
1029
+ "dock_voltage": 21.1,
1030
+ "dock_current": 3.6,
1031
+ "dock_power": 75.9,
1032
+ "power_out": 99.2,
1033
+ },
1034
+ id="prime_charge_base_150w",
1035
+ ),
1010
1036
  ],
1011
1037
  )
1012
1038
  async def test_values(
@@ -1488,10 +1514,7 @@ async def test_telemetry_packet_processing( # noqa: PLR0913, PLR0917
1488
1514
  for packet in packets:
1489
1515
  await mock_bluetooth.send_data([bytes.fromhex(packet)])
1490
1516
 
1491
- device_parameters = (
1492
- device._data.to_str(verbose=False)
1493
- if device._data else None
1494
- )
1517
+ device_parameters = device._data.to_str(verbose=False) if device._data else None
1495
1518
 
1496
1519
  assert parameters == device_parameters, "Parameters do not match expected!"
1497
1520
 
@@ -1569,8 +1592,8 @@ async def test_generic_packet_processing( # noqa: PLR0913, PLR0917
1569
1592
  await mock_bluetooth.send_data([bytes.fromhex(packet)])
1570
1593
 
1571
1594
  for expected_log_entry in expected_logs:
1572
- assert (
1573
- expected_log_entry in str(caplog.text)
1595
+ assert expected_log_entry in str(
1596
+ caplog.text
1574
1597
  ), f"Expected to find '{expected_log_entry}' in logs but it was not found!"
1575
1598
 
1576
1599
 
File without changes
File without changes
File without changes