PyViCare 2.66.0__tar.gz → 2.67.0__tar.gz
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- {pyvicare-2.66.0 → pyvicare-2.67.0}/PKG-INFO +8 -1
- {pyvicare-2.66.0 → pyvicare-2.67.0}/PyViCare/PyViCareDevice.py +20 -0
- {pyvicare-2.66.0 → pyvicare-2.67.0}/PyViCare/PyViCareGazBoiler.py +25 -0
- {pyvicare-2.66.0 → pyvicare-2.67.0}/PyViCare/PyViCareHeatPump.py +10 -3
- {pyvicare-2.66.0 → pyvicare-2.67.0}/README.md +7 -0
- {pyvicare-2.66.0 → pyvicare-2.67.0}/pyproject.toml +3 -3
- {pyvicare-2.66.0 → pyvicare-2.67.0}/.gitignore +0 -0
- {pyvicare-2.66.0 → pyvicare-2.67.0}/LICENSE +0 -0
- {pyvicare-2.66.0 → pyvicare-2.67.0}/PyViCare/Feature.py +0 -0
- {pyvicare-2.66.0 → pyvicare-2.67.0}/PyViCare/PyViCare.py +0 -0
- {pyvicare-2.66.0 → pyvicare-2.67.0}/PyViCare/PyViCareAbstractOAuthManager.py +0 -0
- {pyvicare-2.66.0 → pyvicare-2.67.0}/PyViCare/PyViCareBrowserOAuthManager.py +0 -0
- {pyvicare-2.66.0 → pyvicare-2.67.0}/PyViCare/PyViCareCachedService.py +0 -0
- {pyvicare-2.66.0 → pyvicare-2.67.0}/PyViCare/PyViCareCachedServiceBase.py +0 -0
- {pyvicare-2.66.0 → pyvicare-2.67.0}/PyViCare/PyViCareCachedServiceViaGateway.py +0 -0
- {pyvicare-2.66.0 → pyvicare-2.67.0}/PyViCare/PyViCareDeviceConfig.py +0 -0
- {pyvicare-2.66.0 → pyvicare-2.67.0}/PyViCare/PyViCareElectricalEnergySystem.py +0 -0
- {pyvicare-2.66.0 → pyvicare-2.67.0}/PyViCare/PyViCareEvent.py +0 -0
- {pyvicare-2.66.0 → pyvicare-2.67.0}/PyViCare/PyViCareFloorHeating.py +0 -0
- {pyvicare-2.66.0 → pyvicare-2.67.0}/PyViCare/PyViCareFuelCell.py +0 -0
- {pyvicare-2.66.0 → pyvicare-2.67.0}/PyViCare/PyViCareGateway.py +0 -0
- {pyvicare-2.66.0 → pyvicare-2.67.0}/PyViCare/PyViCareHeatCurveCalculation.py +0 -0
- {pyvicare-2.66.0 → pyvicare-2.67.0}/PyViCare/PyViCareHeatingDevice.py +0 -0
- {pyvicare-2.66.0 → pyvicare-2.67.0}/PyViCare/PyViCareHybrid.py +0 -0
- {pyvicare-2.66.0 → pyvicare-2.67.0}/PyViCare/PyViCareOAuthManager.py +0 -0
- {pyvicare-2.66.0 → pyvicare-2.67.0}/PyViCare/PyViCareOilBoiler.py +0 -0
- {pyvicare-2.66.0 → pyvicare-2.67.0}/PyViCare/PyViCarePelletsBoiler.py +0 -0
- {pyvicare-2.66.0 → pyvicare-2.67.0}/PyViCare/PyViCareRadiatorActuator.py +0 -0
- {pyvicare-2.66.0 → pyvicare-2.67.0}/PyViCare/PyViCareRepeater.py +0 -0
- {pyvicare-2.66.0 → pyvicare-2.67.0}/PyViCare/PyViCareRoomControl.py +0 -0
- {pyvicare-2.66.0 → pyvicare-2.67.0}/PyViCare/PyViCareRoomSensor.py +0 -0
- {pyvicare-2.66.0 → pyvicare-2.67.0}/PyViCare/PyViCareService.py +0 -0
- {pyvicare-2.66.0 → pyvicare-2.67.0}/PyViCare/PyViCareServiceViaGateway.py +0 -0
- {pyvicare-2.66.0 → pyvicare-2.67.0}/PyViCare/PyViCareUtils.py +0 -0
- {pyvicare-2.66.0 → pyvicare-2.67.0}/PyViCare/PyViCareVentilationDevice.py +0 -0
- {pyvicare-2.66.0 → pyvicare-2.67.0}/PyViCare/PyViCareWaterTreatment.py +0 -0
- {pyvicare-2.66.0 → pyvicare-2.67.0}/PyViCare/__init__.py +0 -0
|
@@ -1,6 +1,6 @@
|
|
|
1
1
|
Metadata-Version: 2.5
|
|
2
2
|
Name: PyViCare
|
|
3
|
-
Version: 2.
|
|
3
|
+
Version: 2.67.0
|
|
4
4
|
Summary: Library to communicate with the Viessmann ViCare API.
|
|
5
5
|
Project-URL: Homepage, https://github.com/openviess/PyViCare
|
|
6
6
|
Project-URL: Repository, https://github.com/openviess/PyViCare
|
|
@@ -98,6 +98,13 @@ asks the API for its gateway serial and filters the page by device id, so
|
|
|
98
98
|
`limit` counts that gateway's events. Paging and other event types are on
|
|
99
99
|
`device.service.fetch_events()`.
|
|
100
100
|
|
|
101
|
+
`getDeviceStatusMessages()`, `getDeviceServiceMessages()` and
|
|
102
|
+
`getDeviceInfoMessages()` return the current status, service and info messages
|
|
103
|
+
the same way `getDeviceErrors()` returns the errors, each entry with
|
|
104
|
+
`errorCode`, `priority` and `timestamp`. An empty list means there is no such
|
|
105
|
+
message right now; a device without the feature raises
|
|
106
|
+
`PyViCareNotSupportedFeatureError`.
|
|
107
|
+
|
|
101
108
|
## Types of heatings
|
|
102
109
|
|
|
103
110
|
- Use `asGazBoiler` for gas heatings
|
|
@@ -36,6 +36,26 @@ class Device:
|
|
|
36
36
|
def getDeviceErrors(self) -> list[Any]:
|
|
37
37
|
return list[Any](self.getProperty("device.messages.errors.raw")["properties"]["entries"]["value"])
|
|
38
38
|
|
|
39
|
+
@handleNotSupported
|
|
40
|
+
def getDeviceStatusMessages(self) -> list[Any]:
|
|
41
|
+
return list[Any](self.getProperty("device.messages.status.raw")["properties"]["entries"]["value"])
|
|
42
|
+
|
|
43
|
+
@handleNotSupported
|
|
44
|
+
def getDeviceServiceMessages(self) -> list[Any]:
|
|
45
|
+
return list[Any](self.getProperty("device.messages.service.raw")["properties"]["entries"]["value"])
|
|
46
|
+
|
|
47
|
+
@handleNotSupported
|
|
48
|
+
def getDeviceInfoMessages(self) -> list[Any]:
|
|
49
|
+
return list[Any](self.getProperty("device.messages.info.raw")["properties"]["entries"]["value"])
|
|
50
|
+
|
|
51
|
+
@handleNotSupported
|
|
52
|
+
def getMalfunctionLockActive(self) -> bool:
|
|
53
|
+
return bool(self.getProperty("device.lock.malfunction")["properties"]["active"]["value"])
|
|
54
|
+
|
|
55
|
+
@handleNotSupported
|
|
56
|
+
def getExternalLockActive(self) -> bool:
|
|
57
|
+
return bool(self.getProperty("device.lock.external")["properties"]["active"]["value"])
|
|
58
|
+
|
|
39
59
|
# Power consumption limitation (§14a EnWG):
|
|
40
60
|
@handleNotSupported
|
|
41
61
|
def getPowerConsumptionLimit(self) -> int:
|
|
@@ -8,6 +8,12 @@ from PyViCare.PyViCareHeatingDevice import (
|
|
|
8
8
|
from PyViCare.PyViCareUtils import handleNotSupported
|
|
9
9
|
|
|
10
10
|
|
|
11
|
+
def _burner_stop_reasons(feature: Any) -> list[str]:
|
|
12
|
+
# Every reason comes as "<reason>AllStops"; "timeAllStops" is no reason.
|
|
13
|
+
return sorted(name.removesuffix("AllStops") for name in feature["properties"]
|
|
14
|
+
if name.endswith("AllStops") and name != "timeAllStops")
|
|
15
|
+
|
|
16
|
+
|
|
11
17
|
class GazBoiler(HeatingDevice):
|
|
12
18
|
|
|
13
19
|
@property
|
|
@@ -313,6 +319,25 @@ class GazBoiler(HeatingDevice):
|
|
|
313
319
|
# Returns heating supply pressure
|
|
314
320
|
return float(self.getProperty("heating.sensors.pressure.supply")["properties"]["value"]["value"])
|
|
315
321
|
|
|
322
|
+
# Burner stops per reason (device.timeseries.burner.stops):
|
|
323
|
+
@handleNotSupported
|
|
324
|
+
def getBurnerStopReasons(self) -> list[str]:
|
|
325
|
+
return _burner_stop_reasons(self.getProperty("device.timeseries.burner.stops"))
|
|
326
|
+
|
|
327
|
+
@handleNotSupported
|
|
328
|
+
def getBurnerStopsAll(self, reason: str) -> int:
|
|
329
|
+
return int(self.getProperty("device.timeseries.burner.stops")["properties"][f"{reason}AllStops"]["value"])
|
|
330
|
+
|
|
331
|
+
# Burner stops per reason during domestic hot water heating (device.timeseries.dhw.burner.stops):
|
|
332
|
+
@handleNotSupported
|
|
333
|
+
def getDomesticHotWaterBurnerStopReasons(self) -> list[str]:
|
|
334
|
+
return _burner_stop_reasons(self.getProperty("device.timeseries.dhw.burner.stops"))
|
|
335
|
+
|
|
336
|
+
@handleNotSupported
|
|
337
|
+
def getDomesticHotWaterBurnerStopsAll(self, reason: str) -> int:
|
|
338
|
+
return int(self.getProperty("device.timeseries.dhw.burner.stops")["properties"][f"{reason}AllStops"]["value"])
|
|
339
|
+
|
|
340
|
+
|
|
316
341
|
class GazBurner(HeatingDeviceWithComponent):
|
|
317
342
|
|
|
318
343
|
@property
|
|
@@ -278,13 +278,20 @@ class HeatPump(HeatingDevice, VentilationDevice):
|
|
|
278
278
|
def getAvailableVentilationPrograms(self):
|
|
279
279
|
return self.getVentilationPrograms()
|
|
280
280
|
|
|
281
|
+
def _getDomesticHotWaterHysteresisValue(self, name: str) -> float:
|
|
282
|
+
# some devices serve a value they do not have as {"type": "any", "value": null}
|
|
283
|
+
value = self.getProperty("heating.dhw.temperature.hysteresis")["properties"][name]["value"]
|
|
284
|
+
if value is None:
|
|
285
|
+
raise PyViCareNotSupportedFeatureError(name)
|
|
286
|
+
return float(value)
|
|
287
|
+
|
|
281
288
|
@handleNotSupported
|
|
282
289
|
def getDomesticHotWaterHysteresisUnit(self) -> str:
|
|
283
290
|
return str(self.getProperty("heating.dhw.temperature.hysteresis")["properties"]["value"]["unit"])
|
|
284
291
|
|
|
285
292
|
@handleNotSupported
|
|
286
293
|
def getDomesticHotWaterHysteresis(self) -> float:
|
|
287
|
-
return
|
|
294
|
+
return self._getDomesticHotWaterHysteresisValue("value")
|
|
288
295
|
|
|
289
296
|
@handleNotSupported
|
|
290
297
|
def getDomesticHotWaterHysteresisMin(self) -> float:
|
|
@@ -315,7 +322,7 @@ class HeatPump(HeatingDevice, VentilationDevice):
|
|
|
315
322
|
|
|
316
323
|
@handleNotSupported
|
|
317
324
|
def getDomesticHotWaterHysteresisSwitchOn(self) -> float:
|
|
318
|
-
return
|
|
325
|
+
return self._getDomesticHotWaterHysteresisValue("switchOnValue")
|
|
319
326
|
|
|
320
327
|
@handleNotSupported
|
|
321
328
|
def getDomesticHotWaterHysteresisSwitchOnMin(self) -> float:
|
|
@@ -346,7 +353,7 @@ class HeatPump(HeatingDevice, VentilationDevice):
|
|
|
346
353
|
|
|
347
354
|
@handleNotSupported
|
|
348
355
|
def getDomesticHotWaterHysteresisSwitchOff(self) -> float:
|
|
349
|
-
return
|
|
356
|
+
return self._getDomesticHotWaterHysteresisValue("switchOffValue")
|
|
350
357
|
|
|
351
358
|
@handleNotSupported
|
|
352
359
|
def getDomesticHotWaterHysteresisSwitchOffMin(self) -> float:
|
|
@@ -66,6 +66,13 @@ asks the API for its gateway serial and filters the page by device id, so
|
|
|
66
66
|
`limit` counts that gateway's events. Paging and other event types are on
|
|
67
67
|
`device.service.fetch_events()`.
|
|
68
68
|
|
|
69
|
+
`getDeviceStatusMessages()`, `getDeviceServiceMessages()` and
|
|
70
|
+
`getDeviceInfoMessages()` return the current status, service and info messages
|
|
71
|
+
the same way `getDeviceErrors()` returns the errors, each entry with
|
|
72
|
+
`errorCode`, `priority` and `timestamp`. An empty list means there is no such
|
|
73
|
+
message right now; a device without the feature raises
|
|
74
|
+
`PyViCareNotSupportedFeatureError`.
|
|
75
|
+
|
|
69
76
|
## Types of heatings
|
|
70
77
|
|
|
71
78
|
- Use `asGazBoiler` for gas heatings
|
|
@@ -1,6 +1,6 @@
|
|
|
1
1
|
[project]
|
|
2
2
|
name = "PyViCare"
|
|
3
|
-
version = "2.
|
|
3
|
+
version = "2.67.0"
|
|
4
4
|
description = "Library to communicate with the Viessmann ViCare API."
|
|
5
5
|
authors = [{ name = "Simon Gillet", email = "mail+pyvicare@gillet.ninja" }]
|
|
6
6
|
requires-python = ">=3.11"
|
|
@@ -46,10 +46,10 @@ Changelog = "https://github.com/openviess/PyViCare/releases"
|
|
|
46
46
|
dev = [
|
|
47
47
|
"codespell==2.4.3",
|
|
48
48
|
"mypy==2.4.1",
|
|
49
|
-
"pylint==4.1.
|
|
49
|
+
"pylint==4.1.4",
|
|
50
50
|
"pytest==9.2.0",
|
|
51
51
|
"pytest-cov==7.1.0",
|
|
52
|
-
"ruff==0.17.
|
|
52
|
+
"ruff==0.17.6",
|
|
53
53
|
"types-deprecated>=1.2.15.20241117,<2",
|
|
54
54
|
"types-requests>=2.31",
|
|
55
55
|
]
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|