OpenSimula 0.7.0__tar.gz → 0.8.0__tar.gz
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- {opensimula-0.7.0 → opensimula-0.8.0}/LICENSE +1 -1
- {opensimula-0.7.0 → opensimula-0.8.0}/PKG-INFO +1 -3
- {opensimula-0.7.0 → opensimula-0.8.0}/README.md +0 -1
- {opensimula-0.7.0 → opensimula-0.8.0}/pyproject.toml +2 -3
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/Component.py +10 -5
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/Simulation.py +17 -9
- opensimula-0.8.0/src/OpenSimula/components/Chiller_heat_pump.py +155 -0
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/components/File_data.py +7 -3
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/components/HVAC_MZW_system.py +39 -18
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/components/HVAC_SZW_system.py +129 -42
- opensimula-0.8.0/src/OpenSimula/components/HVAC_water_system.py +314 -0
- opensimula-0.8.0/src/OpenSimula/components/Pump.py +50 -0
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/components/Space.py +186 -91
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/components/Water_coil.py +11 -9
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/components/__init__.py +4 -0
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/visual_3D/Environment_3D.py +29 -4
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/visual_3D/Polygon_3D.py +21 -26
- {opensimula-0.7.0/src/opensimula.egg-info → opensimula-0.8.0/src/OpenSimula.egg-info}/PKG-INFO +1 -3
- {opensimula-0.7.0/src/opensimula.egg-info → opensimula-0.8.0/src/OpenSimula.egg-info}/SOURCES.txt +46 -0
- {opensimula-0.7.0/src/opensimula.egg-info → opensimula-0.8.0/src/OpenSimula.egg-info}/requires.txt +0 -1
- {opensimula-0.7.0 → opensimula-0.8.0}/test/test_HVAC_DX_system.py +7 -7
- opensimula-0.8.0/test/test_HVAC_FAN_COIL_water_system.py +400 -0
- opensimula-0.8.0/test/test_HVAC_water_system_process.py +250 -0
- {opensimula-0.7.0 → opensimula-0.8.0}/setup.cfg +0 -0
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/Child.py +0 -0
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/Iterative_process.py +0 -0
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/Message.py +0 -0
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/Parameter_container.py +0 -0
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/Parameters.py +0 -0
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/Project.py +0 -0
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/Variable.py +0 -0
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/__init__.py +0 -0
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/components/Building.py +0 -0
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/components/Building_surface.py +0 -0
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/components/Calculator.py +0 -0
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/components/Construction.py +0 -0
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/components/DX_unit.py +0 -0
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/components/Day_schedule.py +0 -0
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/components/Fan.py +0 -0
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/components/File_met.py +0 -0
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/components/Frame.py +0 -0
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/components/Glazing.py +0 -0
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/components/HVAC_DX_system.py +0 -0
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/components/HVAC_perfect_system.py +0 -0
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/components/Material.py +0 -0
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/components/Opening.py +0 -0
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/components/Opening_type.py +0 -0
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/components/Solar_surface.py +0 -0
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/components/Space_type.py +0 -0
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/components/Surface.py +0 -0
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/components/Test_component.py +0 -0
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/components/Week_schedule.py +0 -0
- {opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/components/Year_schedule.py +0 -0
- {opensimula-0.7.0/src/opensimula.egg-info → opensimula-0.8.0/src/OpenSimula.egg-info}/dependency_links.txt +0 -0
- {opensimula-0.7.0/src/opensimula.egg-info → opensimula-0.8.0/src/OpenSimula.egg-info}/top_level.txt +0 -0
- {opensimula-0.7.0 → opensimula-0.8.0}/test/test_Calculator.py +0 -0
- {opensimula-0.7.0 → opensimula-0.8.0}/test/test_Case_600FF.py +0 -0
- {opensimula-0.7.0 → opensimula-0.8.0}/test/test_Case_610.py +0 -0
- {opensimula-0.7.0 → opensimula-0.8.0}/test/test_Construction.py +0 -0
- {opensimula-0.7.0 → opensimula-0.8.0}/test/test_File_data.py +0 -0
- {opensimula-0.7.0 → opensimula-0.8.0}/test/test_File_met.py +0 -0
- {opensimula-0.7.0 → opensimula-0.8.0}/test/test_HVAC_DX_Equipment.py +0 -0
- {opensimula-0.7.0 → opensimula-0.8.0}/test/test_Iterative_process.py +0 -0
- {opensimula-0.7.0 → opensimula-0.8.0}/test/test_Project.py +0 -0
- {opensimula-0.7.0 → opensimula-0.8.0}/test/test_Schedules.py +0 -0
|
@@ -1,6 +1,6 @@
|
|
|
1
1
|
Metadata-Version: 2.4
|
|
2
2
|
Name: opensimula
|
|
3
|
-
Version: 0.
|
|
3
|
+
Version: 0.8.0
|
|
4
4
|
Summary: Component-based time simulation environment in Python
|
|
5
5
|
Author-email: "Juan F. Coronel" <jfc@us.es>
|
|
6
6
|
Requires-Python: >=3.12
|
|
@@ -18,7 +18,6 @@ Requires-Dist: psychrolib>=2.5.0
|
|
|
18
18
|
Requires-Dist: scipy>=1.16.2
|
|
19
19
|
Requires-Dist: shapely>=2.1.1
|
|
20
20
|
Requires-Dist: tqdm>=4.67.1
|
|
21
|
-
Requires-Dist: triangle>=20250106
|
|
22
21
|
Requires-Dist: vedo>=2025.5.4
|
|
23
22
|
Dynamic: license-file
|
|
24
23
|
|
|
@@ -44,5 +43,4 @@ Component-based time simulation environment in Python
|
|
|
44
43
|
- nbformat
|
|
45
44
|
- openpyxl
|
|
46
45
|
- tqdm
|
|
47
|
-
- triangle
|
|
48
46
|
- vedo
|
|
@@ -1,6 +1,6 @@
|
|
|
1
1
|
[project]
|
|
2
2
|
name = "opensimula"
|
|
3
|
-
version = "0.
|
|
3
|
+
version = "0.8.0"
|
|
4
4
|
requires-python = ">=3.12"
|
|
5
5
|
authors = [
|
|
6
6
|
{ name="Juan F. Coronel", email="jfc@us.es" },
|
|
@@ -20,8 +20,7 @@ dependencies = [
|
|
|
20
20
|
"scipy>=1.16.2",
|
|
21
21
|
"shapely>=2.1.1",
|
|
22
22
|
"tqdm>=4.67.1",
|
|
23
|
-
|
|
24
|
-
"vedo>=2025.5.4",
|
|
23
|
+
"vedo>=2025.5.4",
|
|
25
24
|
]
|
|
26
25
|
|
|
27
26
|
[dependency-groups]
|
|
@@ -38,7 +38,7 @@ class Component(Parameter_container):
|
|
|
38
38
|
|
|
39
39
|
Args:
|
|
40
40
|
units (bool, optional): Includes unit in the name of the variable. Defaults to True.
|
|
41
|
-
frequency (None or str, optional): frequency of the values: None, "
|
|
41
|
+
frequency (None or str, optional): frequency of the values: None, "hourly", "daily", "monthly", "yearly". Defaults to None.
|
|
42
42
|
value (str, optional): "mean", "sum", "sum_pos", "sum_neg", "max" or "min". Defaults to "mean".
|
|
43
43
|
interval (None or list of two dates): List with the start and end dates of the period to be included in the dataframe, if the value is None all values are included.
|
|
44
44
|
pos_neg_columns (list of str, optional): List of variables that will be included in separate columns positive and negative values. Defaults to [].
|
|
@@ -62,14 +62,19 @@ class Component(Parameter_container):
|
|
|
62
62
|
data[col + "_pos"] = data[col].apply(lambda x: x if x > 0 else 0)
|
|
63
63
|
data[col + "_neg"] = data[col].apply(lambda x: x if x < 0 else 0)
|
|
64
64
|
if frequency is not None:
|
|
65
|
+
freq={"hourly": "h", "daily": "D", "monthly": "ME", "yearly": "YE"}
|
|
65
66
|
if value == "mean":
|
|
66
|
-
data = data.resample(frequency, on='date').mean()
|
|
67
|
+
data = data.resample(freq[frequency], on='date').mean()
|
|
67
68
|
elif value == "sum":
|
|
68
|
-
data = data.resample(frequency, on='date').sum()
|
|
69
|
+
data = data.resample(freq[frequency], on='date').sum()
|
|
70
|
+
elif value == "sum_pos":
|
|
71
|
+
data = data.resample(freq[frequency], on='date').apply(lambda x: x.clip(lower=0).sum())
|
|
72
|
+
elif value == "sum_neg":
|
|
73
|
+
data = data.resample(freq[frequency], on='date').apply(lambda x: x.clip(upper=0).sum())
|
|
69
74
|
elif value == "max":
|
|
70
|
-
data = data.resample(frequency, on='date').max()
|
|
75
|
+
data = data.resample(freq[frequency], on='date').max()
|
|
71
76
|
elif value == "min":
|
|
72
|
-
data = data.resample(frequency, on='date').min()
|
|
77
|
+
data = data.resample(freq[frequency], on='date').min()
|
|
73
78
|
if interval is not None:
|
|
74
79
|
data = data[(data['date'] > interval[0]) &
|
|
75
80
|
(data['date'] < interval[1])]
|
|
@@ -96,18 +96,17 @@ class Simulation:
|
|
|
96
96
|
"""Return the list of messages"""
|
|
97
97
|
return self._messages_
|
|
98
98
|
|
|
99
|
-
def plot(self, dates, variables, names=[], axis=[], frequency=None, value="mean"):
|
|
99
|
+
def plot(self, dates, variables, names=[], axis=[], frequency=None, value="mean",interval=None):
|
|
100
100
|
"""_summary_
|
|
101
101
|
Draw variables graph (using plotly)
|
|
102
102
|
|
|
103
103
|
Args:
|
|
104
104
|
variables: List of hourly variables
|
|
105
105
|
axis: list of axis y 1 or 2 to use for each variable, empty all in first axis
|
|
106
|
-
frequency (None or str, optional): frequency of the values: None, "
|
|
107
|
-
value (str, optional): "mean", "sum", "max" or "min". Defaults to "mean".
|
|
108
|
-
|
|
106
|
+
frequency (None or str, optional): frequency of the values: None, "hourly", "daily", "monthly", "yearly". Defaults to None.
|
|
107
|
+
value (str, optional): "mean", "sum", "sum_pos", "sum_neg", "max" or "min". Defaults to "mean".
|
|
108
|
+
interval (None or list of two dates): List with the start and end dates of the period to be included in the dataframe, if the value is None all values are included.
|
|
109
109
|
"""
|
|
110
|
-
|
|
111
110
|
series = {}
|
|
112
111
|
series["date"] = dates
|
|
113
112
|
for i in range(len(variables)):
|
|
@@ -121,15 +120,24 @@ class Simulation:
|
|
|
121
120
|
series[variables[i].key] = variables[i].values
|
|
122
121
|
data = pd.DataFrame(series)
|
|
123
122
|
if frequency is not None:
|
|
123
|
+
freq={"hourly": "h", "daily": "D", "monthly": "ME", "yearly": "YE"}
|
|
124
124
|
if value == "mean":
|
|
125
|
-
data = data.resample(frequency, on='date').mean()
|
|
125
|
+
data = data.resample(freq[frequency], on='date').mean()
|
|
126
126
|
elif value == "sum":
|
|
127
|
-
data = data.resample(frequency, on='date').sum()
|
|
127
|
+
data = data.resample(freq[frequency], on='date').sum()
|
|
128
|
+
elif value == "sum_pos":
|
|
129
|
+
data = data.resample(freq[frequency], on='date').apply(lambda x: x.clip(lower=0).sum())
|
|
130
|
+
elif value == "sum_neg":
|
|
131
|
+
data = data.resample(freq[frequency], on='date').apply(lambda x: x.clip(upper=0).sum())
|
|
128
132
|
elif value == "max":
|
|
129
|
-
data = data.resample(frequency, on='date').max()
|
|
133
|
+
data = data.resample(freq[frequency], on='date').max()
|
|
130
134
|
elif value == "min":
|
|
131
|
-
data = data.resample(frequency, on='date').min()
|
|
135
|
+
data = data.resample(freq[frequency], on='date').min()
|
|
132
136
|
data["date"] = data.index
|
|
137
|
+
if interval is not None:
|
|
138
|
+
data = data[(data['date'] > interval[0]) &
|
|
139
|
+
(data['date'] < interval[1])]
|
|
140
|
+
|
|
133
141
|
|
|
134
142
|
subfig = make_subplots(specs=[[{"secondary_y": True}]])
|
|
135
143
|
|
|
@@ -0,0 +1,155 @@
|
|
|
1
|
+
from opensimula.Message import Message
|
|
2
|
+
from opensimula.Parameters import Parameter_float, Parameter_float_list, Parameter_math_exp, Parameter_options
|
|
3
|
+
from opensimula.Component import Component
|
|
4
|
+
|
|
5
|
+
class Chiller_heat_pump(Component):
|
|
6
|
+
def __init__(self, name, project):
|
|
7
|
+
Component.__init__(self, name, project)
|
|
8
|
+
self.parameter("type").value = "Chiller"
|
|
9
|
+
self.parameter("description").value = "Chiller equipment manufacturer information"
|
|
10
|
+
self.add_parameter(Parameter_options("chiller_type", "CHILLER", ["CHILLER", "HEAT_PUMP", "CHILLER_HEAT_PUMP"]))
|
|
11
|
+
self.add_parameter(Parameter_options("condensation_type", "AIR_CONDENSED", ["AIR_CONDENSED", "WATER_CONDENSED"]))
|
|
12
|
+
self.add_parameter(Parameter_float("nominal_water_flow", 1, "dm³/s", min=0))
|
|
13
|
+
self.add_parameter(Parameter_float("nominal_cooling_capacity", 0, "W", min=0))
|
|
14
|
+
self.add_parameter(Parameter_float("nominal_cooling_power", 0, "W", min=0))
|
|
15
|
+
self.add_parameter(Parameter_float_list("nominal_cooling_conditions", [35, 12, 7], "ºC"))
|
|
16
|
+
default_cooling_capacity_expression = "1.1239+0.0316*T_wo-0.00986*T_ci"
|
|
17
|
+
self.add_parameter(Parameter_math_exp("cooling_capacity_expression", default_cooling_capacity_expression, "frac"))
|
|
18
|
+
default_cooling_power_expression = "(0.7336-0.00923*T_wo+0.00945*T_ci)*(0.0878+1.138*F_load-0.2258*F_load**2)"
|
|
19
|
+
self.add_parameter(Parameter_math_exp("cooling_power_expression", default_cooling_power_expression, "frac"))
|
|
20
|
+
self.add_parameter(Parameter_math_exp("EER_expression", "1", "frac"))
|
|
21
|
+
self.add_parameter(Parameter_float("nominal_heating_capacity", 0, "W", min=0))
|
|
22
|
+
self.add_parameter(Parameter_float("nominal_heating_power", 0, "W", min=0))
|
|
23
|
+
self.add_parameter(Parameter_float_list("nominal_heating_conditions", [7, 6, 40, 45], "ºC"))
|
|
24
|
+
default_heating_capacity_expression = "1.012+0.028*T_wbci-0.004*T_wo"
|
|
25
|
+
self.add_parameter(Parameter_math_exp("heating_capacity_expression", default_heating_capacity_expression, "frac"))
|
|
26
|
+
default_heating_power_expression = "(0.505-0.0375*T_wbci+0.016*T_wo)*(0.0878+1.138*F_load-0.2258*F_load**2)"
|
|
27
|
+
self.add_parameter(Parameter_math_exp("heating_power_expression", default_heating_power_expression, "frac"))
|
|
28
|
+
self.add_parameter(Parameter_math_exp("COP_expression", "1", "frac"))
|
|
29
|
+
self.add_parameter(Parameter_float_list("expression_max_values", [80,50,50,1.5,1], "-")) # T_wo, T_ci, T_wbci, F_water, F_load
|
|
30
|
+
self.add_parameter(Parameter_float_list("expression_min_values", [0,-30,-30,0,0], "-")) # T_wo, T_ci, T_wbci, F_water, F_load
|
|
31
|
+
|
|
32
|
+
def check(self):
|
|
33
|
+
errors = super().check()
|
|
34
|
+
# Test Cooling and Heating conditions 3 values
|
|
35
|
+
if len(self.parameter("nominal_cooling_conditions").value)!= 3:
|
|
36
|
+
msg = f"Error: {self.parameter('name').value}, nominal_cooling_conditions size must be 3"
|
|
37
|
+
errors.append(Message(msg, "ERROR"))
|
|
38
|
+
if len(self.parameter("nominal_heating_conditions").value)!= 4:
|
|
39
|
+
msg = f"Error: {self.parameter('name').value}, nominal_heating_conditions size must be 4"
|
|
40
|
+
errors.append(Message(msg, "ERROR"))
|
|
41
|
+
return errors
|
|
42
|
+
|
|
43
|
+
def get_heating_load(self,T_wo,T_ci,T_wbci,water_flow,Q_required):
|
|
44
|
+
"""
|
|
45
|
+
Q_required: Required heating load
|
|
46
|
+
Returns (Q_eq,f_load).
|
|
47
|
+
Q_eq: Heating load given by the equipment
|
|
48
|
+
f_load: Fraction of load (0-1)
|
|
49
|
+
"""
|
|
50
|
+
F_water = water_flow/self.parameter("nominal_water_flow").value
|
|
51
|
+
if self.parameter("chiller_type").value == "CHILLER":
|
|
52
|
+
return (0, 0)
|
|
53
|
+
else:
|
|
54
|
+
if Q_required == 0:
|
|
55
|
+
return (0,0)
|
|
56
|
+
# variables dictonary
|
|
57
|
+
var_dic = self._var_state_dic([T_wo, T_ci,T_wbci,F_water,1]) #Full load
|
|
58
|
+
# Capacity
|
|
59
|
+
nom_capacity = self.parameter("nominal_heating_capacity").value
|
|
60
|
+
capacity = nom_capacity * self.parameter("heating_capacity_expression").evaluate(var_dic)
|
|
61
|
+
if Q_required > capacity:
|
|
62
|
+
return (capacity,1)
|
|
63
|
+
else:
|
|
64
|
+
f_load = Q_required/capacity
|
|
65
|
+
return (Q_required, f_load)
|
|
66
|
+
|
|
67
|
+
def get_heating_power(self,T_wo, T_ci,T_wbci,water_flow,Q_required):
|
|
68
|
+
"""
|
|
69
|
+
Returns (tot_power,COP).
|
|
70
|
+
"""
|
|
71
|
+
if self.parameter("chiller_type").value == "CHILLER":
|
|
72
|
+
return (0,0)
|
|
73
|
+
else:
|
|
74
|
+
if Q_required == 0:
|
|
75
|
+
return (0,0)
|
|
76
|
+
Q, F_load = self.get_heating_load(T_wo, T_ci,T_wbci,water_flow,Q_required)
|
|
77
|
+
# variables dictonary
|
|
78
|
+
F_water = water_flow/self.parameter("nominal_water_flow").value
|
|
79
|
+
var_dic = self._var_state_dic([T_wo, T_ci,T_wbci,F_water,F_load])
|
|
80
|
+
# Total power
|
|
81
|
+
nom_power = self.parameter("nominal_heating_power").value
|
|
82
|
+
if (self.parameter("heating_power_expression").value == "1"): ## Use COP expression
|
|
83
|
+
nom_capacity= self.parameter("nominal_heating_capacity").value
|
|
84
|
+
nom_COP = nom_capacity/nom_power
|
|
85
|
+
power = Q/ (nom_COP * self.parameter("COP_expression").evaluate(var_dic))
|
|
86
|
+
else: ## Use heating power expressions
|
|
87
|
+
power = nom_power * self.parameter("heating_power_expression").evaluate(var_dic)
|
|
88
|
+
COP = Q/power
|
|
89
|
+
return (power, COP)
|
|
90
|
+
|
|
91
|
+
def get_cooling_load(self,T_wo,T_ci,T_wbci,water_flow,Q_required):
|
|
92
|
+
"""
|
|
93
|
+
Q_required: Required cooling load
|
|
94
|
+
Returns (Q_eq,f_load).
|
|
95
|
+
Q_eq: Total cool given by the equipment
|
|
96
|
+
f_load: Fraction of load (0-1)
|
|
97
|
+
"""
|
|
98
|
+
F_water = water_flow/self.parameter("nominal_water_flow").value
|
|
99
|
+
if self.parameter("chiller_type").value == "HEAT_PUMP":
|
|
100
|
+
return (0,0)
|
|
101
|
+
else:
|
|
102
|
+
if Q_required == 0:
|
|
103
|
+
return (0,0)
|
|
104
|
+
nom_capacity = self.parameter("nominal_cooling_capacity").value
|
|
105
|
+
# variables dictonary
|
|
106
|
+
var_dic = self._var_state_dic([T_wo,T_ci,T_wbci,F_water,1]) #Full load
|
|
107
|
+
capacity = nom_capacity * self.parameter("cooling_capacity_expression").evaluate(var_dic)
|
|
108
|
+
if Q_required > capacity:
|
|
109
|
+
return (capacity,1)
|
|
110
|
+
else:
|
|
111
|
+
f_load = Q_required/capacity
|
|
112
|
+
return (Q_required, f_load)
|
|
113
|
+
|
|
114
|
+
def get_cooling_power(self,T_wo, T_ci,T_wbci,water_flow,Q_required):
|
|
115
|
+
"""
|
|
116
|
+
Returns (tot_power,EER).
|
|
117
|
+
"""
|
|
118
|
+
if self.parameter("chiller_type").value == "HEAT_PUMP":
|
|
119
|
+
return (0,0)
|
|
120
|
+
else:
|
|
121
|
+
if Q_required == 0:
|
|
122
|
+
return (0,0)
|
|
123
|
+
Q, F_load = self.get_cooling_load(T_wo, T_ci,T_wbci,water_flow,Q_required)
|
|
124
|
+
# variables dictonary
|
|
125
|
+
F_water = water_flow/self.parameter("nominal_water_flow").value
|
|
126
|
+
var_dic = self._var_state_dic([T_wo, T_ci,T_wbci,F_water,F_load])
|
|
127
|
+
# Power
|
|
128
|
+
nom_power = self.parameter("nominal_cooling_power").value
|
|
129
|
+
if (self.parameter("cooling_power_expression").value == "1"): ## Use EER expression
|
|
130
|
+
nom_capacity= self.parameter("nominal_cooling_capacity").value
|
|
131
|
+
nom_EER = nom_capacity/nom_power
|
|
132
|
+
power = Q/ (nom_EER * self.parameter("EER_expression").evaluate(var_dic))
|
|
133
|
+
else: ## Use cooling power expressions
|
|
134
|
+
power = nom_power * self.parameter("cooling_power_expression").evaluate(var_dic)
|
|
135
|
+
COP = Q/power
|
|
136
|
+
return (power, COP)
|
|
137
|
+
|
|
138
|
+
def _var_state_dic(self, values):
|
|
139
|
+
max = self.parameter("expression_max_values").value
|
|
140
|
+
min = self.parameter("expression_min_values").value
|
|
141
|
+
for i in range(len(values)):
|
|
142
|
+
if (values[i] > max[i]):
|
|
143
|
+
values[i] = max[i]
|
|
144
|
+
elif (values[i] < min[i]):
|
|
145
|
+
values[i] = min[i]
|
|
146
|
+
return {"T_wo":values[0],
|
|
147
|
+
"T_ci":values[1],
|
|
148
|
+
"T_wbci":values[2],
|
|
149
|
+
"F_water":values[3],
|
|
150
|
+
"F_load":values[4]}
|
|
151
|
+
|
|
152
|
+
|
|
153
|
+
|
|
154
|
+
|
|
155
|
+
|
|
@@ -40,8 +40,9 @@ class File_data(Component):
|
|
|
40
40
|
self._df_ = pd.read_excel(self.parameter("file_name").value)
|
|
41
41
|
# Create Variable
|
|
42
42
|
for col in self._df_.columns:
|
|
43
|
-
self.
|
|
44
|
-
|
|
43
|
+
if self._is_numeric_(col):
|
|
44
|
+
self.add_variable(Variable(self._extract_name_(
|
|
45
|
+
col), unit=self._extract_unit_(col)))
|
|
45
46
|
|
|
46
47
|
except Exception as ex:
|
|
47
48
|
if type(ex).__name__ == "FileNotFoundError":
|
|
@@ -55,7 +56,7 @@ class File_data(Component):
|
|
|
55
56
|
def pre_simulation(self, n_time_steps, delta_t):
|
|
56
57
|
super().pre_simulation(n_time_steps, delta_t)
|
|
57
58
|
|
|
58
|
-
self.data_array = self._df_.to_numpy()
|
|
59
|
+
self.data_array = self._df_.select_dtypes(include=np.number).to_numpy()
|
|
59
60
|
|
|
60
61
|
if self.parameter("file_step").value == "SIMULATION":
|
|
61
62
|
i = 0
|
|
@@ -100,6 +101,9 @@ class File_data(Component):
|
|
|
100
101
|
return ""
|
|
101
102
|
else:
|
|
102
103
|
return name[name.rfind("[") + 1: name.rfind("]")].strip()
|
|
104
|
+
|
|
105
|
+
def _is_numeric_(self, name):
|
|
106
|
+
return pd.api.types.is_numeric_dtype(self._df_[name])
|
|
103
107
|
|
|
104
108
|
def _get_interpolation_tuple_(self, date):
|
|
105
109
|
seconds = (date-self._initial_date_).total_seconds()
|
{opensimula-0.7.0/src/opensimula → opensimula-0.8.0/src/OpenSimula}/components/HVAC_MZW_system.py
RENAMED
|
@@ -76,10 +76,16 @@ class HVAC_MZW_system(Component): # HVAC Multizone Water system
|
|
|
76
76
|
Parameter_options("fan_operation", "CONTINUOUS", ["CONTINUOUS", "CYCLING"])
|
|
77
77
|
)
|
|
78
78
|
self.add_parameter(
|
|
79
|
-
Parameter_options("water_source", "UNKNOWN", ["UNKNOWN", "
|
|
79
|
+
Parameter_options("water_source", "UNKNOWN", ["UNKNOWN", "WATER_SYSTEM"])
|
|
80
80
|
)
|
|
81
|
-
self.add_parameter(
|
|
82
|
-
|
|
81
|
+
self.add_parameter(
|
|
82
|
+
Parameter_component("cooling_water_system", "not_defined", ["HVAC_water_system"])
|
|
83
|
+
)
|
|
84
|
+
self.add_parameter(
|
|
85
|
+
Parameter_component("heating_water_system", "not_defined", ["HVAC_water_system"])
|
|
86
|
+
)
|
|
87
|
+
self.add_parameter(Parameter_float("cooling_water_flow", 1, "dm³/s", min=0))
|
|
88
|
+
self.add_parameter(Parameter_float("heating_water_flow", 1, "dm³/s", min=0))
|
|
83
89
|
self.add_parameter(Parameter_float("inlet_cooling_water_temp", 7, "ºC"))
|
|
84
90
|
self.add_parameter(Parameter_float("inlet_heating_water_temp", 50, "ºC"))
|
|
85
91
|
self.add_parameter(
|
|
@@ -111,6 +117,13 @@ class HVAC_MZW_system(Component): # HVAC Multizone Water system
|
|
|
111
117
|
"reheat_coils", ["not_defined", "not_defined"], ["Water_coil"]
|
|
112
118
|
)
|
|
113
119
|
)
|
|
120
|
+
self.add_parameter(
|
|
121
|
+
Parameter_options("reheat_water_source", "UNKNOWN", ["UNKNOWN", "WATER_SYSTEM"])
|
|
122
|
+
)
|
|
123
|
+
self.add_parameter(
|
|
124
|
+
Parameter_component("reheat_water_system", "not_defined", ["HVAC_water_system"])
|
|
125
|
+
)
|
|
126
|
+
|
|
114
127
|
|
|
115
128
|
# Variables
|
|
116
129
|
self.add_variable(
|
|
@@ -183,6 +196,24 @@ class HVAC_MZW_system(Component): # HVAC Multizone Water system
|
|
|
183
196
|
f"{self.parameter('name').value}, must define its supply fan equipment."
|
|
184
197
|
)
|
|
185
198
|
errors.append(Message(msg, "ERROR"))
|
|
199
|
+
# Test cooling water system defined
|
|
200
|
+
if self.parameter("water_source").value == "WATER_SYSTEM" and self.parameter("cooling_water_system").value == "not_defined":
|
|
201
|
+
msg = (
|
|
202
|
+
f"{self.parameter('name').value}, must define its cooling water system."
|
|
203
|
+
)
|
|
204
|
+
errors.append(Message(msg, "ERROR"))
|
|
205
|
+
# Test heating water system defined
|
|
206
|
+
if self.parameter("water_source").value == "WATER_SYSTEM" and self.parameter("heating_water_system").value == "not_defined":
|
|
207
|
+
msg = (
|
|
208
|
+
f"{self.parameter('name').value}, must define its heating water system."
|
|
209
|
+
)
|
|
210
|
+
errors.append(Message(msg, "ERROR"))
|
|
211
|
+
# Test reheat water system defined
|
|
212
|
+
if self.parameter("reheat_water_source").value == "WATER_SYSTEM" and self.parameter("reheat_water_system").value == "not_defined":
|
|
213
|
+
msg = (
|
|
214
|
+
f"{self.parameter('name').value}, must define its reheat water system."
|
|
215
|
+
)
|
|
216
|
+
errors.append(Message(msg, "ERROR"))
|
|
186
217
|
# Test file_met defined
|
|
187
218
|
if self.project().parameter("simulation_file_met").value == "not_defined":
|
|
188
219
|
msg = f"{self.parameter('name').value}, file_met must be defined in the project 'simulation_file_met'."
|
|
@@ -221,18 +252,8 @@ class HVAC_MZW_system(Component): # HVAC Multizone Water system
|
|
|
221
252
|
self.reheat_coils = self.parameter("reheat_coils").component
|
|
222
253
|
|
|
223
254
|
# Water flows and temperatures
|
|
224
|
-
self.cooling_water_flow = self.parameter("cooling_water_flow").value
|
|
225
|
-
self.heating_water_flow = self.parameter("heating_water_flow").value
|
|
226
|
-
if self.c_coil:
|
|
227
|
-
self._cooling_F_water = (
|
|
228
|
-
self.cooling_water_flow
|
|
229
|
-
/ self.c_coil.parameter("nominal_cooling_water_flow").value
|
|
230
|
-
)
|
|
231
|
-
if self.h_coil:
|
|
232
|
-
self._heating_F_water = (
|
|
233
|
-
self.heating_water_flow
|
|
234
|
-
/ self.h_coil.parameter("nominal_heating_water_flow").value
|
|
235
|
-
)
|
|
255
|
+
self.cooling_water_flow = self.parameter("cooling_water_flow").value/1000 # Convert to m³/s
|
|
256
|
+
self.heating_water_flow = self.parameter("heating_water_flow").value/1000 # Convert to m³/s
|
|
236
257
|
self.cooling_water_temp = self.parameter("inlet_cooling_water_temp").value
|
|
237
258
|
self.heating_water_temp = self.parameter("inlet_heating_water_temp").value
|
|
238
259
|
self.rho_MA = self.props["RHO_A"]
|
|
@@ -575,7 +596,7 @@ class HVAC_MZW_system(Component): # HVAC Multizone Water system
|
|
|
575
596
|
# Reheat coil
|
|
576
597
|
water_flow = reheat_coil.parameter(
|
|
577
598
|
"nominal_heating_water_flow"
|
|
578
|
-
).value
|
|
599
|
+
).value/1000 # Convert to m³/s
|
|
579
600
|
capacity, epsilon = reheat_coil.get_heating_capacity(
|
|
580
601
|
self.T_SA,
|
|
581
602
|
self.T_SAwb,
|
|
@@ -681,11 +702,11 @@ class HVAC_MZW_system(Component): # HVAC Multizone Water system
|
|
|
681
702
|
self.variable("T_ADP").values[time_index] = 0
|
|
682
703
|
self.variable("epsilon").values[time_index] = self.epsilon
|
|
683
704
|
elif self.state == -1 or self.state == -2: # Cooling
|
|
684
|
-
Q_s =
|
|
705
|
+
Q_s = self.Q_coil
|
|
685
706
|
Q_l = -self.M_w * self.props["LAMBDA"]
|
|
686
707
|
self.variable("Q_sensible").values[time_index] = Q_s
|
|
687
708
|
self.variable("Q_latent").values[time_index] = Q_l
|
|
688
|
-
self.variable("Q_total").values[time_index] = Q_s
|
|
709
|
+
self.variable("Q_total").values[time_index] = -Q_s + Q_l
|
|
689
710
|
self.variable("T_iw").values[time_index] = self.cooling_water_temp
|
|
690
711
|
self.variable("T_ow").values[time_index] = self.cooling_water_temp + (
|
|
691
712
|
Q_s + Q_l
|