GridCalEngine 5.1.52__tar.gz → 5.1.54__tar.gz
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/DataStructures/branch_data.py +20 -4
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/DataStructures/numerical_circuit.py +22 -10
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Aggregation/contingency.py +12 -9
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Aggregation/remedial_action.py +10 -9
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Branches/hvdc_line.py +14 -6
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Branches/transformer3w.py +119 -3
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Diagrams/base_diagram.py +47 -8
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Parents/editable_device.py +3 -2
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/assets.py +21 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_to_gridcal.py +154 -143
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/sv_power_flow.py +6 -4
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/gridcal_to_cgmes.py +143 -48
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/file_handler.py +14 -1
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/raw/devices/psse_circuit.py +11 -18
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/raw/raw_parser_writer.py +4 -2
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/raw/raw_to_gridcal.py +2 -2
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/ContingencyAnalysis/Methods/linear_contingency_analysis.py +7 -4
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/ContingencyAnalysis/Methods/nonlinear_contingency_analysis.py +9 -2
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/ContingencyAnalysis/contingency_analysis_driver.py +7 -2
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/ContingencyAnalysis/contingency_plan.py +15 -6
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/LinearFactors/linear_analysis.py +4 -2
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/PowerFlow/NumericalMethods/newton_raphson_fx.py +11 -30
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/PowerFlow/NumericalMethods/pf_advanced_formulation.py +86 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/PowerFlow/NumericalMethods/pf_basic_formulation.py +30 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/PowerFlow/NumericalMethods/pf_formulation_template.py +8 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/PowerFlow/power_flow_worker.py +18 -3
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/MIP/pulp_interface.py +5 -5
- {GridCalEngine-5.1.52/GridCalEngine → GridCalEngine-5.1.54/GridCalEngine/Utils}/ThirdParty/pulp/__init__.py +7 -4
- {GridCalEngine-5.1.52/GridCalEngine → GridCalEngine-5.1.54/GridCalEngine/Utils}/ThirdParty/pulp/apis/copt_api.py +6 -7
- {GridCalEngine-5.1.52/GridCalEngine → GridCalEngine-5.1.54/GridCalEngine/Utils}/ThirdParty/pulp/apis/cplex_cmd.py +5 -5
- {GridCalEngine-5.1.52/GridCalEngine → GridCalEngine-5.1.54/GridCalEngine/Utils}/ThirdParty/pulp/apis/cplex_py.py +3 -3
- {GridCalEngine-5.1.52/GridCalEngine → GridCalEngine-5.1.54/GridCalEngine/Utils}/ThirdParty/pulp/apis/gurobi_cmd.py +4 -4
- {GridCalEngine-5.1.52/GridCalEngine → GridCalEngine-5.1.54/GridCalEngine/Utils}/ThirdParty/pulp/apis/gurobi_py.py +4 -4
- {GridCalEngine-5.1.52/GridCalEngine → GridCalEngine-5.1.54/GridCalEngine/Utils}/ThirdParty/pulp/apis/highs_cmd.py +3 -3
- {GridCalEngine-5.1.52/GridCalEngine → GridCalEngine-5.1.54/GridCalEngine/Utils}/ThirdParty/pulp/apis/highs_py.py +3 -3
- {GridCalEngine-5.1.52/GridCalEngine → GridCalEngine-5.1.54/GridCalEngine/Utils}/ThirdParty/pulp/apis/lp_solver.py +4 -4
- {GridCalEngine-5.1.52/GridCalEngine → GridCalEngine-5.1.54/GridCalEngine/Utils}/ThirdParty/pulp/apis/lp_solver_cmd.py +1 -1
- {GridCalEngine-5.1.52/GridCalEngine → GridCalEngine-5.1.54/GridCalEngine/Utils}/ThirdParty/pulp/apis/scip_api.py +3 -3
- {GridCalEngine-5.1.52/GridCalEngine → GridCalEngine-5.1.54/GridCalEngine/Utils}/ThirdParty/pulp/apis/xpress_api.py +3 -3
- {GridCalEngine-5.1.52/GridCalEngine → GridCalEngine-5.1.54/GridCalEngine/Utils}/ThirdParty/pulp/model/lp_objects.py +2 -2
- {GridCalEngine-5.1.52/GridCalEngine → GridCalEngine-5.1.54/GridCalEngine/Utils}/ThirdParty/pulp/model/lp_problem.py +8 -8
- {GridCalEngine-5.1.52/GridCalEngine → GridCalEngine-5.1.54/GridCalEngine/Utils}/ThirdParty/pulp/mps_lp.py +2 -2
- {GridCalEngine-5.1.52/GridCalEngine → GridCalEngine-5.1.54/GridCalEngine/Utils}/ThirdParty/pulp/pulp.py +12 -14
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/progress_bar.py +3 -2
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/__version__.py +1 -1
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/enumerations.py +35 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/PKG-INFO +1 -1
- GridCalEngine-5.1.52/GridCalEngine/Utils/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Compilers/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Compilers/circuit_to_bentayga.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Compilers/circuit_to_data.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Compilers/circuit_to_newton_pa.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Compilers/circuit_to_optimods.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Compilers/circuit_to_pgm.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/DataStructures/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/DataStructures/battery_data.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/DataStructures/bus_data.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/DataStructures/fluid_node_data.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/DataStructures/fluid_p2x_data.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/DataStructures/fluid_path_data.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/DataStructures/fluid_pump_data.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/DataStructures/fluid_turbine_data.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/DataStructures/generator_data.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/DataStructures/hvdc_data.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/DataStructures/load_data.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/DataStructures/shunt_data.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/DataStructures/vsc_data.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Aggregation/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Aggregation/area.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Aggregation/branch_group.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Aggregation/community.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Aggregation/contingency_group.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Aggregation/country.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Aggregation/facility.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Aggregation/inter_aggregation_info.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Aggregation/investment.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Aggregation/investments_group.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Aggregation/modelling_authority.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Aggregation/municipality.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Aggregation/region.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Aggregation/remedial_action_group.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Aggregation/zone.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Associations/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Associations/association.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Associations/emission_gas.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Associations/fuel.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Associations/technology.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Branches/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Branches/branch.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Branches/dc_line.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Branches/line.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Branches/line_locations.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Branches/overhead_line_type.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Branches/sequence_line_type.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Branches/series_reactance.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Branches/switch.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Branches/tap_changer.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Branches/transformer.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Branches/transformer_type.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Branches/underground_line_type.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Branches/upfc.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Branches/vsc.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Branches/winding.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Branches/wire.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Diagrams/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Diagrams/graphic_location.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Diagrams/map_diagram.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Diagrams/map_location.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Diagrams/palettes.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Diagrams/schematic_diagram.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Fluid/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Fluid/fluid_injection_template.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Fluid/fluid_node.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Fluid/fluid_p2x.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Fluid/fluid_path.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Fluid/fluid_pump.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Fluid/fluid_turbine.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Injections/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Injections/battery.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Injections/controllable_shunt.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Injections/current_injection.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Injections/external_grid.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Injections/generator.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Injections/generator_q_curve.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Injections/load.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Injections/shunt.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Injections/static_generator.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Parents/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Parents/branch_parent.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Parents/controllable_branch_parent.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Parents/generator_parent.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Parents/injection_parent.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Parents/load_parent.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Parents/physical_device.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Parents/shunt_parent.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Substation/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Substation/bus.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Substation/busbar.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Substation/connectivity_node.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Substation/substation.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Substation/voltage_level.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/comparison.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/measurement.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/multi_circuit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/profile.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/types.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/base/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/base/base_circuit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/base/base_device.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/base/base_property.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/base/units.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/base.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_assets/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_assets/cgmes_2_4_15_assets.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_assets/cgmes_3_0_0_assets.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_circuit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_data_parser.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_data_validator.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_enums.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_export.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_poperty.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_utils.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/ac_line_segment.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/acdc_converter.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/acdc_converterdc_terminal.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/acdc_terminal.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/active_power_limit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/analog_control.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/apparent_power_limit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/asynchronous_machine.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/base_voltage.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/basic_interval_schedule.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/bay.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/breaker.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/bus_name_marker.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/busbar_section.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/conducting_equipment.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/conductor.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/conform_load.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/conform_load_group.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/connectivity_node.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/connectivity_node_container.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/connector.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/control.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/control_area.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/control_area_generating_unit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/coordinate_system.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/cs_converter.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/current_limit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/curve.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/curve_data.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/dc_base_terminal.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/dc_breaker.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/dc_busbar.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/dc_chopper.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/dc_conducting_equipment.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/dc_converter_unit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/dc_disconnector.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/dc_equipment_container.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/dc_ground.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/dc_line.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/dc_line_segment.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/dc_node.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/dc_series_device.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/dc_shunt.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/dc_switch.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/dc_terminal.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/dc_topological_island.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/dc_topological_node.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/disconnector.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/earth_fault_compensator.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/energy_area.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/energy_consumer.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/energy_scheduling_type.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/energy_source.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/equipment.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/equipment_container.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/equivalent_branch.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/equivalent_equipment.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/equivalent_injection.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/equivalent_network.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/equivalent_shunt.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/external_network_injection.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/fossil_fuel.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/full_model.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/generating_unit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/geographical_region.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/ground.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/ground_disconnector.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/grounding_impedance.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/hydro_generating_unit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/hydro_power_plant.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/hydro_pump.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/identified_object.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/junction.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/limit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/limit_set.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/line.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/linear_shunt_compensator.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/load_area.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/load_break_switch.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/load_group.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/load_response_characteristic.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/location.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/measurement.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/measurement_value.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/mutual_coupling.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/non_conform_load.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/non_conform_load_group.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/nonlinear_shunt_compensator.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/nonlinear_shunt_compensator_point.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/nuclear_generating_unit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/operational_limit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/operational_limit_set.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/operational_limit_type.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/per_lengthdc_line_parameter.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/petersen_coil.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/phase_tap_changer.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/phase_tap_changer_asymmetrical.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/phase_tap_changer_linear.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/phase_tap_changer_non_linear.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/phase_tap_changer_symmetrical.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/phase_tap_changer_table.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/phase_tap_changer_table_point.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/phase_tap_changer_tabular.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/position_point.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/power_system_resource.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/power_transformer.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/power_transformer_end.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/protected_switch.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/quality61850.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/ratio_tap_changer.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/ratio_tap_changer_table.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/ratio_tap_changer_table_point.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/reactive_capability_curve.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/regular_interval_schedule.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/regulating_cond_eq.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/regulating_control.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/reporting_group.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/rotating_machine.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/season_day_type_schedule.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/series_compensator.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/shunt_compensator.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/solar_generating_unit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/static_var_compensator.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/sub_geographical_region.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/sub_load_area.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/substation.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/sv_injection.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/sv_power_flow.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/sv_shunt_compensator_sections.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/sv_status.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/sv_tap_step.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/sv_voltage.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/switch.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/synchronous_machine.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/tap_changer.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/tap_changer_control.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/tap_changer_table_point.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/terminal.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/thermal_generating_unit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/tie_flow.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/topological_island.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/topological_node.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/transformer_end.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/voltage_level.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/voltage_limit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/vs_capability_curve.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/vs_converter.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v2_4_15/devices/wind_generating_unit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/ac_line_segment.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/acdc_converter.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/acdc_converterdc_terminal.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/acdc_terminal.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/active_power_limit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/analog_control.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/apparent_power_limit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/asynchronous_machine.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/auxiliary_equipment.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/base_voltage.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/basic_interval_schedule.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/battery_unit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/bay.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/boundary_point.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/breaker.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/bus_name_marker.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/busbar_section.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/caes_plant.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/clamp.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/cogeneration_plant.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/combined_cycle_plant.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/conducting_equipment.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/conductor.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/conform_load.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/conform_load_group.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/connectivity_node.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/connectivity_node_container.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/connector.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/control.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/control_area.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/control_area_generating_unit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/coordinate_system.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/cs_converter.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/current_limit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/current_transformer.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/curve.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/curve_data.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/cut.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/dc_base_terminal.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/dc_breaker.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/dc_busbar.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/dc_chopper.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/dc_conducting_equipment.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/dc_converter_unit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/dc_disconnector.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/dc_equipment_container.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/dc_ground.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/dc_line.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/dc_line_segment.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/dc_node.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/dc_series_device.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/dc_shunt.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/dc_switch.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/dc_terminal.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/dc_topological_island.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/dc_topological_node.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/disconnecting_circuit_breaker.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/disconnector.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/earth_fault_compensator.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/energy_area.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/energy_connection.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/energy_consumer.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/energy_scheduling_type.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/energy_source.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/equipment.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/equipment_container.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/equivalent_branch.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/equivalent_equipment.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/equivalent_injection.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/equivalent_network.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/equivalent_shunt.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/external_network_injection.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/fault_indicator.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/fossil_fuel.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/fuse.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/generating_unit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/geographical_region.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/ground.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/ground_disconnector.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/grounding_impedance.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/hydro_generating_unit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/hydro_power_plant.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/hydro_pump.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/identified_object.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/io_point.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/jumper.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/junction.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/limit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/limit_set.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/line.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/linear_shunt_compensator.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/load_area.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/load_break_switch.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/load_group.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/load_response_characteristic.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/location.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/measurement.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/measurement_value.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/mutual_coupling.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/non_conform_load.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/non_conform_load_group.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/nonlinear_shunt_compensator.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/nonlinear_shunt_compensator_point.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/nuclear_generating_unit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/operational_limit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/operational_limit_set.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/operational_limit_type.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/petersen_coil.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/phase_tap_changer.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/phase_tap_changer_asymmetrical.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/phase_tap_changer_linear.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/phase_tap_changer_non_linear.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/phase_tap_changer_symmetrical.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/phase_tap_changer_table.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/phase_tap_changer_table_point.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/phase_tap_changer_tabular.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/photo_voltaic_unit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/position_point.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/post_line_sensor.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/potential_transformer.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/power_electronics_connection.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/power_electronics_unit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/power_electronics_wind_unit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/power_system_resource.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/power_transformer.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/power_transformer_end.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/protected_switch.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/ratio_tap_changer.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/ratio_tap_changer_table.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/ratio_tap_changer_table_point.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/reactive_capability_curve.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/regular_interval_schedule.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/regulating_cond_eq.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/regulating_control.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/reporting_group.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/rotating_machine.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/season_day_type_schedule.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/sensor.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/series_compensator.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/service_location.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/shunt_compensator.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/solar_generating_unit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/solar_power_plant.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/static_var_compensator.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/sub_geographical_region.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/sub_load_area.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/substation.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/surge_arrester.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/sv_injection.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/sv_shunt_compensator_sections.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/sv_status.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/sv_switch.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/sv_tap_step.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/sv_voltage.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/switch.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/synchronous_machine.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/tap_changer.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/tap_changer_control.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/tap_changer_table_point.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/terminal.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/thermal_generating_unit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/tie_flow.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/topological_island.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/topological_node.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/transformer_end.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/voltage_level.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/voltage_limit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/vs_capability_curve.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/vs_converter.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/wave_trap.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/wind_generating_unit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/wind_power_plant.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_v3_0_0/devices/work_location.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/cgmes_writer.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/rdfs_infos.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cgmes/rdfs_serializations.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cim16/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cim16/cim_circuit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cim16/cim_data_parser.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cim16/cim_devices.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cim16/cim_enums.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/cim16/cim_parser.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/db/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/db/base_db.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/db/cgmes_lookup_db.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/db/db_handler.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/db/file_system.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/cim/db/psse_lookup_db.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/dgs/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/dgs/dgs_parser.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/epc/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/epc/epc_parser.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/file_system.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/gridcal/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/gridcal/catalogue.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/gridcal/contingency_parser.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/gridcal/excel_interface.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/gridcal/generic_io_functions.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/gridcal/h5_interface.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/gridcal/json_parser.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/gridcal/pack_unpack.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/gridcal/remote.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/gridcal/results_export.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/gridcal/sqlite_interface.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/gridcal/zip_interface.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/matpower/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/matpower/matpower_branch_definitions.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/matpower/matpower_bus_definitions.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/matpower/matpower_gen_definitions.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/matpower/matpower_parser.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/matpower/matpower_storage_definitions.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/others/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/others/dpx_parser.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/others/ipa_parser.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/others/plx_parser.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/others/pypsa_parser.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/raw/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/raw/devices/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/raw/devices/area.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/raw/devices/branch.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/raw/devices/bus.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/raw/devices/facts.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/raw/devices/fixed_shunt.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/raw/devices/generator.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/raw/devices/gne_device.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/raw/devices/induction_machine.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/raw/devices/inter_area.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/raw/devices/load.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/raw/devices/node.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/raw/devices/owner.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/raw/devices/psse_object.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/raw/devices/psse_property.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/raw/devices/substation.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/raw/devices/switched_shunt.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/raw/devices/system_switching_device.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/raw/devices/transformer.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/raw/devices/two_terminal_dc_line.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/raw/devices/vsc_dc_line.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/raw/devices/zone.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/raw/gridcal_to_raw.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/raw/raw_functions.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/IO/raw/rawx_parser_writer.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/LICENSE.txt +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/ATC/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/ATC/available_transfer_capacity_driver.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/ATC/available_transfer_capacity_options.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/ATC/available_transfer_capacity_ts_driver.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/Clustering/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/Clustering/clustering.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/Clustering/clustering_driver.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/Clustering/clustering_options.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/Clustering/clustering_results.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/ContingencyAnalysis/Methods/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/ContingencyAnalysis/Methods/helm_contingencies.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/ContingencyAnalysis/Methods/helm_contingency_analysis.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/ContingencyAnalysis/Methods/optimal_linear_contingency_analysis.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/ContingencyAnalysis/Methods/srap.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/ContingencyAnalysis/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/ContingencyAnalysis/contingencies_report.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/ContingencyAnalysis/contingency_analysis_options.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/ContingencyAnalysis/contingency_analysis_results.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/ContingencyAnalysis/contingency_analysis_ts_driver.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/ContingencyAnalysis/contingency_analysis_ts_results.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/ContinuationPowerFlow/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/ContinuationPowerFlow/continuation_power_flow.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/ContinuationPowerFlow/continuation_power_flow_driver.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/ContinuationPowerFlow/continuation_power_flow_input.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/ContinuationPowerFlow/continuation_power_flow_options.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/ContinuationPowerFlow/continuation_power_flow_results.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/Derivatives/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/Derivatives/ac_jacobian.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/Derivatives/acdc_jacobian.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/Derivatives/csc_derivatives.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/Derivatives/csr_derivatives.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/Derivatives/matpower_derivatives.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/Dynamics/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/Dynamics/dynamic_modules.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/Dynamics/transient_stability_driver.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/InputsAnalysis/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/InputsAnalysis/inputs_analysis_driver.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/InvestmentsEvaluation/Methods/NSGA_3.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/InvestmentsEvaluation/Methods/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/InvestmentsEvaluation/Methods/mixed_variable_NSGA_2.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/InvestmentsEvaluation/Methods/random_eval.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/InvestmentsEvaluation/Methods/stop_crits.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/InvestmentsEvaluation/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/InvestmentsEvaluation/investments_evaluation_driver.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/InvestmentsEvaluation/investments_evaluation_options.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/InvestmentsEvaluation/investments_evaluation_results.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/LinearFactors/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/LinearFactors/linear_analysis_driver.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/LinearFactors/linear_analysis_options.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/LinearFactors/linear_analysis_results.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/LinearFactors/linear_analysis_ts_driver.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/LinearFactors/linear_analysis_ts_results.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/NTC/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/NTC/ntc_driver.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/NTC/ntc_opf.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/NTC/ntc_options.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/NTC/ntc_results.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/NTC/ntc_ts_driver.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/NTC/ntc_ts_results.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/NodalCapacity/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/NodalCapacity/nodal_capacity_options.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/NodalCapacity/nodal_capacity_ts_driver.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/NodalCapacity/nodal_capacity_ts_results.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/OPF/NumericalMethods/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/OPF/NumericalMethods/ac_opf.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/OPF/NumericalMethods/ac_opf_autodif.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/OPF/NumericalMethods/ac_opf_derivatives.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/OPF/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/OPF/linear_opf_ts.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/OPF/opf_driver.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/OPF/opf_options.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/OPF/opf_results.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/OPF/opf_ts_driver.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/OPF/opf_ts_results.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/OPF/simple_dispatch_ts.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/PowerFlow/NumericalMethods/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/PowerFlow/NumericalMethods/common_functions.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/PowerFlow/NumericalMethods/discrete_controls.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/PowerFlow/NumericalMethods/fast_decoupled.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/PowerFlow/NumericalMethods/gauss_power_flow.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/PowerFlow/NumericalMethods/helm_power_flow.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/PowerFlow/NumericalMethods/iwamoto_newton_raphson.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/PowerFlow/NumericalMethods/levenberg_marquadt_fx.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/PowerFlow/NumericalMethods/linearized_power_flow.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/PowerFlow/NumericalMethods/powell_fx.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/PowerFlow/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/PowerFlow/grid_analysis.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/PowerFlow/power_flow_driver.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/PowerFlow/power_flow_options.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/PowerFlow/power_flow_results.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/PowerFlow/power_flow_ts_driver.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/PowerFlow/power_flow_ts_input.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/PowerFlow/power_flow_ts_results.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/ShortCircuitStudies/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/ShortCircuitStudies/short_circuit.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/ShortCircuitStudies/short_circuit_driver.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/ShortCircuitStudies/short_circuit_options.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/ShortCircuitStudies/short_circuit_results.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/ShortCircuitStudies/short_circuit_worker.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/SigmaAnalysis/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/SigmaAnalysis/sigma_analysis_driver.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/StateEstimation/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/StateEstimation/state_estimation.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/StateEstimation/state_stimation_driver.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/Stochastic/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/Stochastic/blackout_driver.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/Stochastic/latin_hypercube_sampling.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/Stochastic/reliability_driver.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/Stochastic/reliability_iterable.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/Stochastic/stochastic_power_flow_driver.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/Stochastic/stochastic_power_flow_input.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/Stochastic/stochastic_power_flow_results.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/Topology/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/Topology/node_groups_driver.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/Topology/topology_processor_driver.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/Topology/topology_reduction_driver.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/driver_template.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/driver_types.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/options_template.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/results_table.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/results_template.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Simulations/types.py +0 -0
- {GridCalEngine-5.1.52/GridCalEngine/ThirdParty → GridCalEngine-5.1.54/GridCalEngine/Topology}/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Topology/admittance_matrices.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Topology/detect_substations.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Topology/simulation_indices.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Topology/topology.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Topology/topology_processor.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/Filtering/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/Filtering/filtering.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/Filtering/objects_filtering.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/Filtering/results_table_filtering.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/Filtering/timeseries_filtering.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/MIP/SimpleMip/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/MIP/SimpleMip/highs.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/MIP/SimpleMip/lpmodel.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/MIP/SimpleMip/lpobjects.py +0 -0
- {GridCalEngine-5.1.52/GridCalEngine/ThirdParty/pulp/model → GridCalEngine-5.1.54/GridCalEngine/Utils/MIP}/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/MIP/ortools_interface.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/MIP/selected_interface.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/NumericalMethods/MVRSM_mo_pareto.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/NumericalMethods/MVRSM_mo_scaled.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/NumericalMethods/MVRSM_original.py +0 -0
- {GridCalEngine-5.1.52/GridCalEngine/Topology → GridCalEngine-5.1.54/GridCalEngine/Utils/NumericalMethods}/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/NumericalMethods/autodiff.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/NumericalMethods/common.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/NumericalMethods/ips.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/NumericalMethods/iwamoto.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/NumericalMethods/levenberg_marquadt.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/NumericalMethods/newton_raphson.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/NumericalMethods/newton_raphson_ode.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/NumericalMethods/non_dominated_sorting.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/NumericalMethods/nsga3.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/NumericalMethods/numerical_stability.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/NumericalMethods/powell.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/NumericalMethods/sparse_solve.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/NumericalMethods/weldorf_online_stddev.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/Sparse/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/Sparse/csc.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/Sparse/csc2.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/Sparse/csc_numba.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/Sparse/sparse_array.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/Sparse/utils.py +0 -0
- {GridCalEngine-5.1.52/GridCalEngine/Utils/MIP → GridCalEngine-5.1.54/GridCalEngine/Utils/ThirdParty/SyntheticNetworks}/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/ThirdParty/SyntheticNetworks/rpgm_algo.py +0 -0
- {GridCalEngine-5.1.52/GridCalEngine/Utils/NumericalMethods → GridCalEngine-5.1.54/GridCalEngine/Utils/ThirdParty}/__init__.py +0 -0
- {GridCalEngine-5.1.52/GridCalEngine → GridCalEngine-5.1.54/GridCalEngine/Utils}/ThirdParty/pulp/apis/__init__.py +0 -0
- {GridCalEngine-5.1.52/GridCalEngine → GridCalEngine-5.1.54/GridCalEngine/Utils}/ThirdParty/pulp/constants.py +0 -0
- {GridCalEngine-5.1.52/GridCalEngine/Utils/ThirdParty/SyntheticNetworks → GridCalEngine-5.1.54/GridCalEngine/Utils/ThirdParty/pulp/model}/__init__.py +0 -0
- {GridCalEngine-5.1.52/GridCalEngine → GridCalEngine-5.1.54/GridCalEngine/Utils}/ThirdParty/pulp/paths.py +0 -0
- {GridCalEngine-5.1.52/GridCalEngine → GridCalEngine-5.1.54/GridCalEngine/Utils}/ThirdParty/pulp/sparse.py +0 -0
- {GridCalEngine-5.1.52/GridCalEngine → GridCalEngine-5.1.54/GridCalEngine/Utils}/ThirdParty/pulp/utilities.py +0 -0
- {GridCalEngine-5.1.52/GridCalEngine/Utils/ThirdParty → GridCalEngine-5.1.54/GridCalEngine/Utils}/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/scores.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Utils/zip_file_mgmt.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/__init__.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/api.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/basic_structures.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/data_logger.py +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/setup.cfg +0 -0
- {GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/setup.py +0 -0
@@ -14,13 +14,15 @@
|
|
14
14
|
# You should have received a copy of the GNU Lesser General Public License
|
15
15
|
# along with this program; if not, write to the Free Software Foundation,
|
16
16
|
# Inc., 51 Franklin Street, Fifth Floor, Boston, MA 02110-1301, USA.
|
17
|
+
from __future__ import annotations
|
18
|
+
|
17
19
|
import numpy as np
|
18
20
|
import pandas as pd
|
19
21
|
import scipy.sparse as sp
|
20
22
|
import GridCalEngine.Topology.topology as tp
|
21
23
|
from GridCalEngine.enumerations import WindingsConnection
|
22
24
|
from GridCalEngine.Utils.Sparse.sparse_array import SparseObjectArray
|
23
|
-
from GridCalEngine.basic_structures import Vec, IntVec, StrVec, ObjVec, CxVec, BoolVec
|
25
|
+
from GridCalEngine.basic_structures import Vec, IntVec, StrVec, ObjVec, CxVec, BoolVec, Logger
|
24
26
|
from typing import List, Tuple, Dict, Set
|
25
27
|
|
26
28
|
|
@@ -126,11 +128,12 @@ class BranchData:
|
|
126
128
|
|
127
129
|
return self.nelm
|
128
130
|
|
129
|
-
def slice(self, elm_idx: IntVec, bus_idx: IntVec) -> "BranchData":
|
131
|
+
def slice(self, elm_idx: IntVec, bus_idx: IntVec, logger: Logger | None) -> "BranchData":
|
130
132
|
"""
|
131
133
|
Slice branch data by given indices
|
132
134
|
:param elm_idx: array of branch indices
|
133
135
|
:param bus_idx: array of bus indices
|
136
|
+
:param logger: Logger
|
134
137
|
:return: new BranchData instance
|
135
138
|
"""
|
136
139
|
|
@@ -204,8 +207,21 @@ class BranchData:
|
|
204
207
|
data.T = self.T[elm_idx]
|
205
208
|
bus_map: Dict[int, int] = {o: i for i, o in enumerate(bus_idx)}
|
206
209
|
for k in range(data.nelm):
|
207
|
-
data.F[k] = bus_map
|
208
|
-
|
210
|
+
data.F[k] = bus_map.get(data.F[k], -1)
|
211
|
+
|
212
|
+
if data.F[k] == -1:
|
213
|
+
if logger is not None:
|
214
|
+
logger.add_error(f"Branch {k}, {self.names[k]} if connected to a disconnected node",
|
215
|
+
value=data.F[k])
|
216
|
+
data.active[k] = 0
|
217
|
+
|
218
|
+
data.T[k] = bus_map.get(data.T[k], -1)
|
219
|
+
|
220
|
+
if data.T[k] == -1:
|
221
|
+
if logger is not None:
|
222
|
+
logger.add_error(f"Branch {k}, {self.names[k]} if connected to a disconnected node",
|
223
|
+
value=data.T[k])
|
224
|
+
data.active[k] = 0
|
209
225
|
|
210
226
|
data.overload_cost = self.overload_cost[elm_idx]
|
211
227
|
|
{GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/DataStructures/numerical_circuit.py
RENAMED
@@ -24,7 +24,7 @@ from GridCalEngine.Devices import RemedialAction
|
|
24
24
|
from GridCalEngine.basic_structures import Logger
|
25
25
|
from GridCalEngine.Devices.multi_circuit import MultiCircuit
|
26
26
|
from GridCalEngine.basic_structures import Vec, IntVec, CxVec
|
27
|
-
from GridCalEngine.enumerations import BranchImpedanceMode, BusMode
|
27
|
+
from GridCalEngine.enumerations import BranchImpedanceMode, BusMode, ContingencyOperationTypes
|
28
28
|
import GridCalEngine.Topology.topology as tp
|
29
29
|
import GridCalEngine.Topology.simulation_indices as si
|
30
30
|
|
@@ -494,12 +494,12 @@ class NumericalCircuit:
|
|
494
494
|
structure, idx = self.structs_dict.get(cnt.device_idtag, (None, 0))
|
495
495
|
|
496
496
|
if structure is not None:
|
497
|
-
if cnt.prop ==
|
497
|
+
if cnt.prop == ContingencyOperationTypes.Active:
|
498
498
|
if revert:
|
499
499
|
structure.active[idx] = int(not bool(cnt.value))
|
500
500
|
else:
|
501
501
|
structure.active[idx] = int(cnt.value)
|
502
|
-
elif cnt.prop ==
|
502
|
+
elif cnt.prop == ContingencyOperationTypes.PowerPercentage:
|
503
503
|
if revert:
|
504
504
|
structure.p[idx] /= float(cnt.value / 100.0)
|
505
505
|
else:
|
@@ -528,12 +528,12 @@ class NumericalCircuit:
|
|
528
528
|
structure, idx = self.structs_dict.get(cnt.device_idtag, (None, 0))
|
529
529
|
|
530
530
|
if structure is not None:
|
531
|
-
if cnt.prop ==
|
531
|
+
if cnt.prop == ContingencyOperationTypes.Active:
|
532
532
|
if revert:
|
533
533
|
structure.active[idx] = int(not bool(cnt.value))
|
534
534
|
else:
|
535
535
|
structure.active[idx] = int(cnt.value)
|
536
|
-
elif cnt.prop ==
|
536
|
+
elif cnt.prop == ContingencyOperationTypes.PowerPercentage:
|
537
537
|
# TODO Cambiar el acceso a P por una función (o función que incremente- decremente porcentaje)
|
538
538
|
assert not isinstance(structure, ds.HvdcData) # TODO Arreglar esto
|
539
539
|
dev_injections = np.zeros(structure.size())
|
@@ -1834,13 +1834,17 @@ class NumericalCircuit:
|
|
1834
1834
|
return df
|
1835
1835
|
|
1836
1836
|
def get_island(self, bus_idx: IntVec,
|
1837
|
-
consider_hvdc_as_island_links: bool = False
|
1837
|
+
consider_hvdc_as_island_links: bool = False,
|
1838
|
+
logger: Logger | None = None) -> "NumericalCircuit":
|
1838
1839
|
"""
|
1839
1840
|
Get the island corresponding to the given buses
|
1840
1841
|
:param bus_idx: array of bus indices
|
1841
1842
|
:param consider_hvdc_as_island_links: Does the HVDCLine works for the topology as a normal line?
|
1843
|
+
:param logger: Logger
|
1842
1844
|
:return: SnapshotData
|
1843
1845
|
"""
|
1846
|
+
if logger is None:
|
1847
|
+
logger = Logger()
|
1844
1848
|
|
1845
1849
|
# if the island is the same as the original bus indices, no slicing is needed
|
1846
1850
|
if len(bus_idx) == len(self.bus_data.original_idx):
|
@@ -1875,7 +1879,7 @@ class NumericalCircuit:
|
|
1875
1879
|
|
1876
1880
|
# slice data
|
1877
1881
|
nc.bus_data = self.bus_data.slice(elm_idx=bus_idx)
|
1878
|
-
nc.branch_data = self.branch_data.slice(elm_idx=br_idx, bus_idx=bus_idx)
|
1882
|
+
nc.branch_data = self.branch_data.slice(elm_idx=br_idx, bus_idx=bus_idx, logger=logger)
|
1879
1883
|
|
1880
1884
|
nc.load_data = self.load_data.slice(elm_idx=load_idx, bus_idx=bus_idx)
|
1881
1885
|
nc.battery_data = self.battery_data.slice(elm_idx=batt_idx, bus_idx=bus_idx)
|
@@ -1890,13 +1894,17 @@ class NumericalCircuit:
|
|
1890
1894
|
|
1891
1895
|
def split_into_islands(self,
|
1892
1896
|
ignore_single_node_islands: bool = False,
|
1893
|
-
consider_hvdc_as_island_links: bool = False
|
1897
|
+
consider_hvdc_as_island_links: bool = False,
|
1898
|
+
logger: Logger | None = None) -> List["NumericalCircuit"]:
|
1894
1899
|
"""
|
1895
1900
|
Split circuit into islands
|
1896
1901
|
:param ignore_single_node_islands: ignore islands composed of only one bus
|
1897
1902
|
:param consider_hvdc_as_island_links: Does the HVDCLine works for the topology as a normal line?
|
1903
|
+
:param logger: Logger
|
1898
1904
|
:return: List[NumericCircuit]
|
1899
1905
|
"""
|
1906
|
+
if logger is None:
|
1907
|
+
logger = Logger()
|
1900
1908
|
|
1901
1909
|
# find the matching islands
|
1902
1910
|
adj = self.compute_adjacency_matrix(consider_hvdc_as_island_links=consider_hvdc_as_island_links)
|
@@ -1907,10 +1915,14 @@ class NumericalCircuit:
|
|
1907
1915
|
for bus_idx in idx_islands:
|
1908
1916
|
if ignore_single_node_islands:
|
1909
1917
|
if len(bus_idx) > 1:
|
1910
|
-
island = self.get_island(bus_idx,
|
1918
|
+
island = self.get_island(bus_idx,
|
1919
|
+
consider_hvdc_as_island_links=consider_hvdc_as_island_links,
|
1920
|
+
logger=logger)
|
1911
1921
|
circuit_islands.append(island)
|
1912
1922
|
else:
|
1913
|
-
island = self.get_island(bus_idx,
|
1923
|
+
island = self.get_island(bus_idx,
|
1924
|
+
consider_hvdc_as_island_links=consider_hvdc_as_island_links,
|
1925
|
+
logger=logger)
|
1914
1926
|
circuit_islands.append(island)
|
1915
1927
|
|
1916
1928
|
return circuit_islands
|
{GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Aggregation/contingency.py
RENAMED
@@ -18,6 +18,7 @@
|
|
18
18
|
from typing import Union
|
19
19
|
from GridCalEngine.Devices.Parents.editable_device import EditableDevice, DeviceType
|
20
20
|
from GridCalEngine.Devices.Aggregation.contingency_group import ContingencyGroup
|
21
|
+
from GridCalEngine.enumerations import ContingencyOperationTypes
|
21
22
|
|
22
23
|
|
23
24
|
class Contingency(EditableDevice):
|
@@ -29,7 +30,9 @@ class Contingency(EditableDevice):
|
|
29
30
|
idtag: Union[str, None] = None,
|
30
31
|
device_idtag='',
|
31
32
|
name="Contingency",
|
32
|
-
code='',
|
33
|
+
code='',
|
34
|
+
prop: ContingencyOperationTypes = ContingencyOperationTypes.Active,
|
35
|
+
value=0.0,
|
33
36
|
group: Union[None, ContingencyGroup] = None):
|
34
37
|
"""
|
35
38
|
Contingency
|
@@ -49,13 +52,13 @@ class Contingency(EditableDevice):
|
|
49
52
|
|
50
53
|
# Contingency type
|
51
54
|
self.device_idtag = device_idtag
|
52
|
-
self._prop = prop
|
55
|
+
self._prop: ContingencyOperationTypes = prop
|
53
56
|
self._value = value
|
54
57
|
self._group: ContingencyGroup = group
|
55
|
-
self._allowed_properties = ['active', '%']
|
56
58
|
|
57
59
|
self.register(key='device_idtag', units='', tpe=str, definition='Unique ID', editable=False)
|
58
|
-
self.register(key='prop', units='', tpe=
|
60
|
+
self.register(key='prop', units='', tpe=ContingencyOperationTypes,
|
61
|
+
definition=f'Object property to change')
|
59
62
|
self.register(key='value', units='', tpe=float, definition='Property value')
|
60
63
|
self.register(key='group', units='', tpe=DeviceType.ContingencyGroupDevice, definition='Contingency group')
|
61
64
|
|
@@ -68,19 +71,19 @@ class Contingency(EditableDevice):
|
|
68
71
|
self._name = val
|
69
72
|
|
70
73
|
@property
|
71
|
-
def prop(self) ->
|
74
|
+
def prop(self) -> ContingencyOperationTypes:
|
72
75
|
"""
|
73
76
|
Property to modify when contingency is triggered out
|
74
|
-
:return:
|
77
|
+
:return: ContingencyOperationsTypes
|
75
78
|
"""
|
76
79
|
return self._prop
|
77
80
|
|
78
81
|
@prop.setter
|
79
|
-
def prop(self, val:
|
80
|
-
if val
|
82
|
+
def prop(self, val: ContingencyOperationTypes):
|
83
|
+
if isinstance(val, ContingencyOperationTypes):
|
81
84
|
self._prop = val
|
82
85
|
else:
|
83
|
-
print(f"Not allowed property {val}
|
86
|
+
print(f"Not allowed property {val}")
|
84
87
|
|
85
88
|
@property
|
86
89
|
def value(self) -> float:
|
{GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Aggregation/remedial_action.py
RENAMED
@@ -18,6 +18,7 @@
|
|
18
18
|
from typing import Union
|
19
19
|
from GridCalEngine.Devices.Parents.editable_device import EditableDevice, DeviceType
|
20
20
|
from GridCalEngine.Devices.Aggregation.remedial_action_group import RemedialActionGroup
|
21
|
+
from GridCalEngine.enumerations import ContingencyOperationTypes
|
21
22
|
|
22
23
|
|
23
24
|
class RemedialAction(EditableDevice):
|
@@ -30,7 +31,7 @@ class RemedialAction(EditableDevice):
|
|
30
31
|
device_idtag='',
|
31
32
|
name="Remedial action",
|
32
33
|
code='',
|
33
|
-
prop=
|
34
|
+
prop: ContingencyOperationTypes = ContingencyOperationTypes.Active,
|
34
35
|
value=0.0,
|
35
36
|
group: Union[None, RemedialActionGroup] = None):
|
36
37
|
"""
|
@@ -51,13 +52,13 @@ class RemedialAction(EditableDevice):
|
|
51
52
|
|
52
53
|
# Contingency type
|
53
54
|
self.device_idtag = device_idtag
|
54
|
-
self._prop = prop
|
55
|
+
self._prop: ContingencyOperationTypes = prop
|
55
56
|
self._value = value
|
56
57
|
self._group: RemedialActionGroup = group
|
57
|
-
self._allowed_properties = ['active', '%']
|
58
58
|
|
59
59
|
self.register(key='device_idtag', units='', tpe=str, definition='Unique ID', editable=False)
|
60
|
-
self.register(key='prop', units='', tpe=
|
60
|
+
self.register(key='prop', units='', tpe=ContingencyOperationTypes,
|
61
|
+
definition=f'Object property to change')
|
61
62
|
self.register(key='value', units='', tpe=float, definition='Property value')
|
62
63
|
self.register(key='group', units='', tpe=DeviceType.RemedialActionGroupDevice,
|
63
64
|
definition='Remedial action group')
|
@@ -71,19 +72,19 @@ class RemedialAction(EditableDevice):
|
|
71
72
|
self._name = val
|
72
73
|
|
73
74
|
@property
|
74
|
-
def prop(self) ->
|
75
|
+
def prop(self) -> ContingencyOperationTypes:
|
75
76
|
"""
|
76
77
|
Property to modify when contingency is triggered out
|
77
|
-
:return:
|
78
|
+
:return: ContingencyOperationsTypes
|
78
79
|
"""
|
79
80
|
return self._prop
|
80
81
|
|
81
82
|
@prop.setter
|
82
|
-
def prop(self, val:
|
83
|
-
if val
|
83
|
+
def prop(self, val: ContingencyOperationTypes):
|
84
|
+
if isinstance(val, ContingencyOperationTypes):
|
84
85
|
self._prop = val
|
85
86
|
else:
|
86
|
-
print(f"Not allowed property {val}
|
87
|
+
print(f"Not allowed property {val}")
|
87
88
|
|
88
89
|
@property
|
89
90
|
def value(self) -> float:
|
@@ -145,7 +145,8 @@ class HvdcLine(BranchParent):
|
|
145
145
|
overload_cost=1000.0, min_firing_angle_f=-1.0, max_firing_angle_f=1.0, min_firing_angle_t=-1.0,
|
146
146
|
max_firing_angle_t=1.0, contingency_factor=1.0, protection_rating_factor: float = 1.4,
|
147
147
|
control_mode: HvdcControlType = HvdcControlType.type_1_Pset, dispatchable=True, angle_droop=0,
|
148
|
-
capex=0, opex=0, build_status: BuildStatus = BuildStatus.Commissioned,
|
148
|
+
capex=0, opex=0, build_status: BuildStatus = BuildStatus.Commissioned,
|
149
|
+
dc_link_voltage: float = 200):
|
149
150
|
"""
|
150
151
|
HVDC Line model
|
151
152
|
:param bus_from: Bus from
|
@@ -199,6 +200,10 @@ class HvdcLine(BranchParent):
|
|
199
200
|
|
200
201
|
self.r = float(r)
|
201
202
|
|
203
|
+
self.dc_link_voltage = float(dc_link_voltage)
|
204
|
+
|
205
|
+
# self.n_lines = int(n_lines)
|
206
|
+
|
202
207
|
self.angle_droop = float(angle_droop)
|
203
208
|
|
204
209
|
self.loss_factor = float(loss_factor)
|
@@ -238,8 +243,6 @@ class HvdcLine(BranchParent):
|
|
238
243
|
self._Vset_t_prof: Vec = Profile(default_value=Vset_t, data_type=float)
|
239
244
|
self._angle_droop_prof: Vec = Profile(default_value=angle_droop, data_type=float)
|
240
245
|
|
241
|
-
self.n_lines = n_lines
|
242
|
-
|
243
246
|
# Line locations
|
244
247
|
self._locations: LineLocations = LineLocations()
|
245
248
|
|
@@ -248,11 +251,16 @@ class HvdcLine(BranchParent):
|
|
248
251
|
self.register(key='control_mode', units='-', tpe=HvdcControlType, definition='Control type.')
|
249
252
|
self.register(key='Pset', units='MW', tpe=float, definition='Set power flow.', profile_name='Pset_prof')
|
250
253
|
self.register(key='r', units='Ohm', tpe=float, definition='line resistance.')
|
254
|
+
self.register(key='dc_link_voltage', units='kV', tpe=float,
|
255
|
+
definition='line voltage (only for compatibility, not used in calcs.)')
|
256
|
+
|
251
257
|
self.register(key='angle_droop', units='MW/deg', tpe=float, definition='Power/angle rate control',
|
252
258
|
profile_name='angle_droop_prof')
|
253
|
-
|
254
|
-
|
255
|
-
|
259
|
+
|
260
|
+
# self.register(key='n_lines', units='', tpe=int,
|
261
|
+
# definition='Number of parallel lines between the converter stations. '
|
262
|
+
# 'The rating will be equally divided')
|
263
|
+
|
256
264
|
self.register(key='Vset_f', units='p.u.', tpe=float, definition='Set voltage at the from side',
|
257
265
|
profile_name='Vset_f_prof')
|
258
266
|
self.register(key='Vset_t', units='p.u.', tpe=float, definition='Set voltage at the to side',
|
{GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Branches/transformer3w.py
RENAMED
@@ -18,6 +18,7 @@
|
|
18
18
|
from typing import Tuple, Union
|
19
19
|
import numpy as np
|
20
20
|
from GridCalEngine.Devices.Substation.bus import Bus
|
21
|
+
from GridCalEngine.Devices.Substation.connectivity_node import ConnectivityNode
|
21
22
|
from GridCalEngine.Devices.Parents.physical_device import PhysicalDevice
|
22
23
|
from GridCalEngine.Devices.Branches.winding import Winding
|
23
24
|
from GridCalEngine.Devices.Branches.transformer_type import get_impedances
|
@@ -28,6 +29,7 @@ from GridCalEngine.enumerations import DeviceType
|
|
28
29
|
def delta_to_star(z12: float, z23: float, z31: float) -> Tuple[float, float, float]:
|
29
30
|
"""
|
30
31
|
Perform the delta->star transformation
|
32
|
+
See: https://www.electronics-tutorials.ws/dccircuits/dcp_10.html
|
31
33
|
:param z12: 1 to 2 delta value
|
32
34
|
:param z23: 2 to 3 delta value
|
33
35
|
:param z31: 3 to 1 delta value
|
@@ -43,6 +45,23 @@ def delta_to_star(z12: float, z23: float, z31: float) -> Tuple[float, float, flo
|
|
43
45
|
return 1e-20, 1e-20, 1e-20
|
44
46
|
|
45
47
|
|
48
|
+
def star_to_delta(z1: float, z2: float, z3: float) -> Tuple[float, float, float]:
|
49
|
+
"""
|
50
|
+
Perform the star->delta transformation
|
51
|
+
See: https://www.electronics-tutorials.ws/dccircuits/dcp_10.html
|
52
|
+
:param z1: 0->1 impedance
|
53
|
+
:param z2: 0->2 impedance
|
54
|
+
:param z3: 0->3 impedance
|
55
|
+
:return: z12, z23, z31 impedances
|
56
|
+
"""
|
57
|
+
zt = z1 * z2 + z2 * z3 + z3 * z1
|
58
|
+
z12 = zt / z3
|
59
|
+
z23 = zt / z2
|
60
|
+
z31 = zt / z1
|
61
|
+
|
62
|
+
return z12, z23, z31
|
63
|
+
|
64
|
+
|
46
65
|
class Transformer3W(PhysicalDevice):
|
47
66
|
|
48
67
|
def __init__(self, idtag: Union[str, None] = None,
|
@@ -50,6 +69,10 @@ class Transformer3W(PhysicalDevice):
|
|
50
69
|
name: str = 'Branch',
|
51
70
|
bus0: Union[None, Bus] = None,
|
52
71
|
bus1: Bus = None, bus2: Bus = None, bus3: Bus = None,
|
72
|
+
cn0: Union[None, ConnectivityNode] = None,
|
73
|
+
cn1: ConnectivityNode = None,
|
74
|
+
cn2: ConnectivityNode = None,
|
75
|
+
cn3: ConnectivityNode = None,
|
53
76
|
w1_idtag: Union[str, None] = None,
|
54
77
|
w2_idtag: Union[str, None] = None,
|
55
78
|
w3_idtag: Union[str, None] = None,
|
@@ -95,10 +118,23 @@ class Transformer3W(PhysicalDevice):
|
|
95
118
|
bus0.Vnom = 1.0
|
96
119
|
self.bus0 = bus0
|
97
120
|
|
121
|
+
if cn0 is None:
|
122
|
+
self.cn0 = ConnectivityNode(name=name + '_cn', Vnom=1.0, internal=True)
|
123
|
+
else:
|
124
|
+
cn0.is_internal = True
|
125
|
+
cn0.Vnom = 1.0
|
126
|
+
self.cn0 = cn0
|
127
|
+
|
128
|
+
self.cn0.default_bus = self.bus0
|
129
|
+
|
98
130
|
self._bus1 = bus1
|
99
131
|
self._bus2 = bus2
|
100
132
|
self._bus3 = bus3
|
101
133
|
|
134
|
+
self._cn1 = cn1
|
135
|
+
self._cn2 = cn2
|
136
|
+
self._cn3 = cn3
|
137
|
+
|
102
138
|
self.active = bool(active)
|
103
139
|
self._active_prof = Profile(default_value=self.active, data_type=bool)
|
104
140
|
|
@@ -130,9 +166,21 @@ class Transformer3W(PhysicalDevice):
|
|
130
166
|
self._Pfe: float = 0.0
|
131
167
|
self._I0: float = 0.0
|
132
168
|
|
133
|
-
self._winding1 = Winding(bus_from=self.bus0, idtag=w1_idtag,
|
134
|
-
|
135
|
-
|
169
|
+
self._winding1 = Winding(bus_from=self.bus0, idtag=w1_idtag,
|
170
|
+
bus_to=bus1,
|
171
|
+
cn_from=self.cn0,
|
172
|
+
cn_to=self.cn1,
|
173
|
+
HV=V1, LV=1.0, name=name + "_W1")
|
174
|
+
self._winding2 = Winding(bus_from=self.bus0, idtag=w2_idtag,
|
175
|
+
bus_to=bus2,
|
176
|
+
cn_from=self.cn0,
|
177
|
+
cn_to=self.cn2,
|
178
|
+
HV=V2, LV=1.0, name=name + "_W2")
|
179
|
+
self._winding3 = Winding(bus_from=self.bus0, idtag=w3_idtag,
|
180
|
+
bus_to=bus3,
|
181
|
+
cn_from=self.cn0,
|
182
|
+
cn_to=self.cn3,
|
183
|
+
HV=V3, LV=1.0, name=name + "_W3")
|
136
184
|
|
137
185
|
self.x = float(x)
|
138
186
|
self.y = float(y)
|
@@ -143,6 +191,16 @@ class Transformer3W(PhysicalDevice):
|
|
143
191
|
self.register(key='bus2', units='', tpe=DeviceType.BusDevice, definition='Bus 2.', editable=False)
|
144
192
|
self.register(key='bus3', units='', tpe=DeviceType.BusDevice, definition='Bus 3.', editable=False)
|
145
193
|
|
194
|
+
self.register(key='cn0', units='', tpe=DeviceType.ConnectivityNodeDevice,
|
195
|
+
definition='Middle point connection cn.',
|
196
|
+
editable=False)
|
197
|
+
self.register(key='cn1', units='', tpe=DeviceType.ConnectivityNodeDevice, definition='ConnectivityNode 1.',
|
198
|
+
editable=False)
|
199
|
+
self.register(key='cn2', units='', tpe=DeviceType.ConnectivityNodeDevice, definition='ConnectivityNode 2.',
|
200
|
+
editable=False)
|
201
|
+
self.register(key='cn3', units='', tpe=DeviceType.ConnectivityNodeDevice, definition='ConnectivityNode 3.',
|
202
|
+
editable=False)
|
203
|
+
|
146
204
|
self.register('active', units="", tpe=bool, definition='Is active?', profile_name="active_prof")
|
147
205
|
|
148
206
|
self.register(key='winding1', units='', tpe=DeviceType.WindingDevice, definition='Winding 1.', editable=False)
|
@@ -269,6 +327,42 @@ class Transformer3W(PhysicalDevice):
|
|
269
327
|
if obj is not None:
|
270
328
|
self.winding3.set_hv_and_lv(self.winding3.HV, self.winding3.LV)
|
271
329
|
|
330
|
+
@property
|
331
|
+
def cn1(self) -> ConnectivityNode:
|
332
|
+
"""
|
333
|
+
ConnectivityNode 1
|
334
|
+
"""
|
335
|
+
return self._cn1
|
336
|
+
|
337
|
+
@cn1.setter
|
338
|
+
def cn1(self, obj: ConnectivityNode):
|
339
|
+
self._cn1 = obj
|
340
|
+
self.winding1.cn_to = obj
|
341
|
+
|
342
|
+
@property
|
343
|
+
def cn2(self) -> ConnectivityNode:
|
344
|
+
"""
|
345
|
+
ConnectivityNode 2
|
346
|
+
"""
|
347
|
+
return self._cn2
|
348
|
+
|
349
|
+
@cn2.setter
|
350
|
+
def cn2(self, obj: ConnectivityNode):
|
351
|
+
self._cn2 = obj
|
352
|
+
self.winding2.cn_to = obj
|
353
|
+
|
354
|
+
@property
|
355
|
+
def cn3(self) -> ConnectivityNode:
|
356
|
+
"""
|
357
|
+
ConnectivityNode 3
|
358
|
+
"""
|
359
|
+
return self._cn3
|
360
|
+
|
361
|
+
@cn3.setter
|
362
|
+
def cn3(self, obj: ConnectivityNode):
|
363
|
+
self._cn3 = obj
|
364
|
+
self.winding3.cn_to = obj
|
365
|
+
|
272
366
|
@property
|
273
367
|
def V1(self) -> float:
|
274
368
|
"""
|
@@ -326,6 +420,28 @@ class Transformer3W(PhysicalDevice):
|
|
326
420
|
self.winding3.X = x3
|
327
421
|
self.winding3.rate = self.rate3
|
328
422
|
|
423
|
+
def fill_from_star(self, r1: float, r2: float, r3: float, x1: float, x2: float, x3: float) -> None:
|
424
|
+
"""
|
425
|
+
Fill from Star values
|
426
|
+
:param r1: resistance of the branch 1 (p.u.)
|
427
|
+
:param r2: resistance of the branch 2 (p.u.)
|
428
|
+
:param r3: resistance of the branch 3 (p.u.)
|
429
|
+
:param x1: reactance of the branch 1 (p.u.)
|
430
|
+
:param x2: reactance of the branch 2 (p.u.)
|
431
|
+
:param x3: reactance of the branch 3 (p.u.)
|
432
|
+
"""
|
433
|
+
self._r12, self._r23, self._r31 = star_to_delta(z1=r1, z2=r2, z3=r3)
|
434
|
+
self._x12, self._x23, self._x31 = star_to_delta(z1=x1, z2=x2, z3=x3)
|
435
|
+
|
436
|
+
self.winding1.R = r1
|
437
|
+
self.winding1.X = x1
|
438
|
+
|
439
|
+
self.winding2.R = r2
|
440
|
+
self.winding2.X = x2
|
441
|
+
|
442
|
+
self.winding3.R = r3
|
443
|
+
self.winding3.X = x3
|
444
|
+
|
329
445
|
@property
|
330
446
|
def r12(self):
|
331
447
|
"""
|
{GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Diagrams/base_diagram.py
RENAMED
@@ -135,6 +135,7 @@ class BaseDiagram:
|
|
135
135
|
max_branch_width=5,
|
136
136
|
min_bus_width=20,
|
137
137
|
max_bus_width=20,
|
138
|
+
arrow_size=20,
|
138
139
|
palette: Colormaps = Colormaps.GridCal,
|
139
140
|
default_bus_voltage: float = 10):
|
140
141
|
"""
|
@@ -147,6 +148,7 @@ class BaseDiagram:
|
|
147
148
|
:param max_branch_width:
|
148
149
|
:param min_bus_width:
|
149
150
|
:param max_bus_width:
|
151
|
+
:param arrow_size:
|
150
152
|
:param palette:
|
151
153
|
:param default_bus_voltage:
|
152
154
|
"""
|
@@ -169,6 +171,7 @@ class BaseDiagram:
|
|
169
171
|
self._max_branch_width: float = max_branch_width
|
170
172
|
self._min_bus_width: float = min_bus_width
|
171
173
|
self._max_bus_width: float = max_bus_width
|
174
|
+
self._arrow_size: float = arrow_size
|
172
175
|
|
173
176
|
self._palette = palette
|
174
177
|
self._default_bus_voltage: float = default_bus_voltage
|
@@ -188,6 +191,10 @@ class BaseDiagram:
|
|
188
191
|
# min_branch_width property
|
189
192
|
@property
|
190
193
|
def min_branch_width(self) -> float:
|
194
|
+
"""
|
195
|
+
|
196
|
+
:return:
|
197
|
+
"""
|
191
198
|
return self._min_branch_width
|
192
199
|
|
193
200
|
@min_branch_width.setter
|
@@ -197,6 +204,10 @@ class BaseDiagram:
|
|
197
204
|
# max_branch_width property
|
198
205
|
@property
|
199
206
|
def max_branch_width(self) -> float:
|
207
|
+
"""
|
208
|
+
|
209
|
+
:return:
|
210
|
+
"""
|
200
211
|
return self._max_branch_width
|
201
212
|
|
202
213
|
@max_branch_width.setter
|
@@ -206,24 +217,48 @@ class BaseDiagram:
|
|
206
217
|
# min_bus_width property
|
207
218
|
@property
|
208
219
|
def min_bus_width(self) -> float:
|
220
|
+
"""
|
221
|
+
|
222
|
+
:return:
|
223
|
+
"""
|
209
224
|
return self._min_bus_width
|
210
225
|
|
211
226
|
@min_bus_width.setter
|
212
227
|
def min_bus_width(self, value: float):
|
213
228
|
self._min_bus_width = value
|
214
229
|
|
215
|
-
|
230
|
+
|
216
231
|
@property
|
217
232
|
def max_bus_width(self) -> float:
|
233
|
+
"""
|
234
|
+
|
235
|
+
:return:
|
236
|
+
"""
|
218
237
|
return self._max_bus_width
|
219
238
|
|
220
239
|
@max_bus_width.setter
|
221
240
|
def max_bus_width(self, value: float):
|
222
241
|
self._max_bus_width = value
|
223
242
|
|
243
|
+
@property
|
244
|
+
def arrow_size(self) -> float:
|
245
|
+
"""
|
246
|
+
|
247
|
+
:return:
|
248
|
+
"""
|
249
|
+
return self._arrow_size
|
250
|
+
|
251
|
+
@arrow_size.setter
|
252
|
+
def arrow_size(self, value: float):
|
253
|
+
self._arrow_size = value
|
254
|
+
|
224
255
|
# palette property
|
225
256
|
@property
|
226
257
|
def palette(self) -> Colormaps:
|
258
|
+
"""
|
259
|
+
|
260
|
+
:return:
|
261
|
+
"""
|
227
262
|
return self._palette
|
228
263
|
|
229
264
|
@palette.setter
|
@@ -234,6 +269,10 @@ class BaseDiagram:
|
|
234
269
|
# default_bus_voltage property
|
235
270
|
@property
|
236
271
|
def default_bus_voltage(self) -> float:
|
272
|
+
"""
|
273
|
+
|
274
|
+
:return:
|
275
|
+
"""
|
237
276
|
return self._default_bus_voltage
|
238
277
|
|
239
278
|
@default_bus_voltage.setter
|
@@ -322,6 +361,8 @@ class BaseDiagram:
|
|
322
361
|
"max_branch_width": self.max_branch_width,
|
323
362
|
"min_bus_width": self.min_bus_width,
|
324
363
|
"max_bus_width": self.max_bus_width,
|
364
|
+
"arrow_size": self.arrow_size,
|
365
|
+
|
325
366
|
"palette": self.palette.value,
|
326
367
|
"default_bus_voltage": self.default_bus_voltage,
|
327
368
|
'data': data}
|
@@ -345,6 +386,7 @@ class BaseDiagram:
|
|
345
386
|
self.max_branch_width: float = data.get("max_branch_width", 5)
|
346
387
|
self.min_bus_width: float = data.get("min_bus_width", 20)
|
347
388
|
self.max_bus_width: float = data.get("max_bus_width", 20)
|
389
|
+
self.arrow_size: float = data.get("arrow_size", 20)
|
348
390
|
self.palette = Colormaps(data.get("palette", 'GridCal'))
|
349
391
|
self.default_bus_voltage = data.get("default_bus_voltage", 10)
|
350
392
|
|
@@ -473,7 +515,8 @@ class BaseDiagram:
|
|
473
515
|
min_branch_width: int = 5,
|
474
516
|
max_branch_width=5,
|
475
517
|
min_bus_width=20,
|
476
|
-
max_bus_width=20
|
518
|
+
max_bus_width=20,
|
519
|
+
arrow_size=20):
|
477
520
|
"""
|
478
521
|
Set the size constraints
|
479
522
|
:param use_flow_based_width:
|
@@ -481,15 +524,11 @@ class BaseDiagram:
|
|
481
524
|
:param max_branch_width:
|
482
525
|
:param min_bus_width:
|
483
526
|
:param max_bus_width:
|
527
|
+
:param arrow_size:
|
484
528
|
"""
|
485
529
|
self.use_flow_based_width: bool = use_flow_based_width
|
486
530
|
self.min_branch_width: float = min_branch_width
|
487
531
|
self.max_branch_width: float = max_branch_width
|
488
532
|
self.min_bus_width: float = min_bus_width
|
489
533
|
self.max_bus_width: float = max_bus_width
|
490
|
-
|
491
|
-
# print(f"{self.use_flow_based_width}, "
|
492
|
-
# f"{self.min_branch_width}, "
|
493
|
-
# f"{self.max_branch_width}, "
|
494
|
-
# f"{self.min_bus_width}, "
|
495
|
-
# f"{self.max_bus_width}")
|
534
|
+
self.arrow_size = arrow_size
|
{GridCalEngine-5.1.52 → GridCalEngine-5.1.54}/GridCalEngine/Devices/Parents/editable_device.py
RENAMED
@@ -25,7 +25,7 @@ from GridCalEngine.enumerations import (DeviceType, TimeFrame, BuildStatus, Wind
|
|
25
25
|
CpfParametrization, CpfStopAt, InvestmentEvaluationMethod, SolverType,
|
26
26
|
InvestmentsEvaluationObjectives, NodalCapacityMethod, TimeGrouping,
|
27
27
|
ZonalGrouping, MIPSolvers, AcOpfMode, SubstationTypes,
|
28
|
-
BranchImpedanceMode, FaultType, TapChangerTypes)
|
28
|
+
BranchImpedanceMode, FaultType, TapChangerTypes, ContingencyOperationTypes)
|
29
29
|
|
30
30
|
# types that can be assigned to a GridCal property
|
31
31
|
GCPROP_TYPES = Union[
|
@@ -56,7 +56,8 @@ GCPROP_TYPES = Union[
|
|
56
56
|
Type[BranchImpedanceMode],
|
57
57
|
Type[FaultType],
|
58
58
|
Type[TapChangerTypes],
|
59
|
-
Type[SubstationTypes]
|
59
|
+
Type[SubstationTypes],
|
60
|
+
Type[ContingencyOperationTypes]
|
60
61
|
]
|
61
62
|
|
62
63
|
|