EnergySystemModels 20260416005__tar.gz → 20260416007__tar.gz
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/PKG-INFO +1 -1
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/setup.py +1 -1
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Combustion/NG_Boiler_Efficiency_EN1295X.py +75 -18
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/energysystemmodels.egg-info/PKG-INFO +1 -1
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/LICENSE +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/README.md +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/setup.cfg +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/AirPort/AirPort.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/AirPort/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/Coil/CoolingCoil.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/Coil/CoolingCoil_Expert.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/Coil/CoolingCoil_Sensible.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/Coil/CoolingCoil_Tc.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/Coil/HeatingCoil.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/Coil/HeatingCoilNUT.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/Coil/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/Connect.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/FreshAir/AirMix.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/FreshAir/FreshAir.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/FreshAir/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/GenericAHU/AirRecoveryAHU.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/GenericAHU/AirRecyclingAHU.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/GenericAHU/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/HeatRecovery/Heat_plate_exchanger.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/HeatRecovery/Thermal_wheel_exchanger.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/HeatRecovery/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/Humidification/Humidifier.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/Humidification/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/air_humide/PsychrometricChart.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/air_humide/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/air_humide/air_humide.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/air_humide/air_humide_NB.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/CEE/CEE.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/CEE/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/Distillation/Deethanizer.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/Distillation/PengRobinson.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/Distillation/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/Distillation/diag_enthalpy_models.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/Distillation/reverse_engineer_enthalpies.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/Facture/ATR_Transport_Distribution.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/Facture/SONALGAZ_Elec.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/Facture/SONALGAZ_gaz.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/Facture/TURPE.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/Facture/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/Facture/coefficients_elec.json +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/Facture/coefficients_gaz_ATRD.json +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/Facture/coefficients_gaz_ATRT.json +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/Facture/coefficients_gaz_TICGN.json +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/Facture/coefficients_gaz_TVA.json +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/Facture/coefficients_sonalgaz_elec.json +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/Facture/coefficients_sonalgaz_gaz.json +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/Facture/df_utils.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/Facture/test.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/HeatTransfer/CompositeWall.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/HeatTransfer/ParallelepipedicBody.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/HeatTransfer/PipeInsulationAnalysis.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/HeatTransfer/PlateHeatTransfer.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/HeatTransfer/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/IPMVP/IPMVP.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/IPMVP/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/MeteoCiel/DJU_costic.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/MeteoCiel/MeteoCiel_Scraping.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/MeteoCiel/MeteoCiel_dayScraping.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/MeteoCiel/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/NodeEditor/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/NodeEditor/nodeeditor/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/NodeEditor/nodeeditor/node_content_widget.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/NodeEditor/nodeeditor/node_edge.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/NodeEditor/nodeeditor/node_edge_dragging.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/NodeEditor/nodeeditor/node_edge_validators.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/NodeEditor/nodeeditor/node_editor_widget.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/NodeEditor/nodeeditor/node_editor_window.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/NodeEditor/nodeeditor/node_graphics_cutline.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/NodeEditor/nodeeditor/node_graphics_edge.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/NodeEditor/nodeeditor/node_graphics_edge_path.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/NodeEditor/nodeeditor/node_graphics_node.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/NodeEditor/nodeeditor/node_graphics_scene.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/NodeEditor/nodeeditor/node_graphics_socket.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/NodeEditor/nodeeditor/node_graphics_view.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/NodeEditor/nodeeditor/node_node.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/NodeEditor/nodeeditor/node_scene.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/NodeEditor/nodeeditor/node_scene_clipboard.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/NodeEditor/nodeeditor/node_scene_history.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/NodeEditor/nodeeditor/node_serializable.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/NodeEditor/nodeeditor/node_socket.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/NodeEditor/nodeeditor/utils.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/NodeEditor/setup.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/NodeEditor/tests/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/NodeEditor/tests/test_000_import.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/NodeEditor/tox.ini +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/OpenWeatherMap/OpenWeatherMap_call.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/OpenWeatherMap/OpenWeatherMap_call_location.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/OpenWeatherMap/SQlite_OpenWeatherMap.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/OpenWeatherMap/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/OpenWeatherMap/config.ini +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/OpenWeatherMap/config_historical.ini +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/OpenWeatherMap/data.json +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/OpenWeatherMap/get_weather.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PV/ProductionElectriquePV.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PV/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PinchAnalysis/PinchAnalysis.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PinchAnalysis/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PinchAnalysis/functions/Two_flow_pinch_analysis.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PinchAnalysis/functions/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PinchAnalysis/functions/apply_heat_exchange_above.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PinchAnalysis/functions/apply_heat_exchange_below.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PinchAnalysis/functions/calculation_HEN.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PinchAnalysis/functions/calculation_allowed_combinations.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PinchAnalysis/functions/calculation_below_above_stream.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PinchAnalysis/functions/calculation_composite_curve.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PinchAnalysis/functions/calculation_decomposition.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PinchAnalysis/functions/calculation_graphical_HEN.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PinchAnalysis/functions/calculation_surplus_deficit.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PinchAnalysis/functions/check_additional_heat_exchanges.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PinchAnalysis/functions/draw_hen_from_df.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PinchAnalysis/functions/plotting.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/calc_conf.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/calc_drag_listbox.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/calc_node_base.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/calc_sub_window.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/calc_window.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/config.ini +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/main.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/nodes/Simple_HEX.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/nodes/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/nodes/air_input.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/nodes/air_mixer.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/nodes/air_output.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/nodes/compressor.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/nodes/compressor_m.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/nodes/condenser.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/nodes/cooling_coil.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/nodes/cooling_coil_expert.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/nodes/cooling_coil_sensible.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/nodes/desuperheater.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/nodes/evaporator.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/nodes/expansion_valve.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/nodes/heating_coil.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/nodes/humidificateur.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/nodes/input.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/nodes/operations.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/nodes/output.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/nodes/random_meteo.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/nodes/source_P_h.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/nodes/turbine.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Aeraulic/StraightPipe.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Aeraulic/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Carnot_Cycle_Analysis.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Chiller.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Combustion/Combustor_cantera.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Combustion/Gaz_Boiler.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Combustion/NG_Heating_Value.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Combustion/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Compressor/Compressor.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Compressor/Compressor_m.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Compressor/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Condenser/Condenser.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Condenser/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Connect.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Desuperheater/Desuperheater.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Desuperheater/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Evaporator/Evaporator.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Evaporator/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Expansion_Valve/Expansion_Valve.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Expansion_Valve/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/FluidPort/FluidPort.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/FluidPort/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/HEX/AirCooled_HEX.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/HEX/DTLM_HEX.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/HEX/NUT_HEX.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/HEX/Simple_HEX.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/HEX/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Hydraulic/StraightPipe.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Hydraulic/TA_Valve.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Hydraulic/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Pump/Pump.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Pump/Pump_m.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Pump/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Sink/Sink.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Sink/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Source/Source.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Source/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Tank/MixedStorage.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Tank/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Temperature_Entropy_Chart.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Turbine/Turbine.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Turbine/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/TkinterGUI/Chiller.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/TkinterGUI/__init__.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/energysystemmodels.egg-info/SOURCES.txt +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/energysystemmodels.egg-info/dependency_links.txt +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/energysystemmodels.egg-info/requires.txt +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/energysystemmodels.egg-info/top_level.txt +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/test/test_api_diagnostic.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/test/test_api_key.py +0 -0
- {energysystemmodels-20260416005 → energysystemmodels-20260416007}/test/test_compare_keys.py +0 -0
|
@@ -1,6 +1,6 @@
|
|
|
1
1
|
Metadata-Version: 2.4
|
|
2
2
|
Name: energysystemmodels
|
|
3
|
-
Version:
|
|
3
|
+
Version: 20260416007
|
|
4
4
|
Summary: Energy systems models are the mathematical models that are developed in order to represent as reliably as possible various energy-related problems.
|
|
5
5
|
Author: Zoheir HADID
|
|
6
6
|
Author-email: zoheir.hadid@gmail.com
|
|
@@ -11,7 +11,7 @@ setup(
|
|
|
11
11
|
name='energysystemmodels',
|
|
12
12
|
|
|
13
13
|
|
|
14
|
-
version='
|
|
14
|
+
version='20260416007',
|
|
15
15
|
|
|
16
16
|
description='Energy systems models are the mathematical models that are developed in order to represent as reliably as possible various energy-related problems.',
|
|
17
17
|
|
|
@@ -3,12 +3,19 @@ import pandas as pd
|
|
|
3
3
|
import re
|
|
4
4
|
from ThermodynamicCycles.Combustion.NG_Heating_Value import NG_Heating_Value
|
|
5
5
|
|
|
6
|
+
try:
|
|
7
|
+
from CoolProp.CoolProp import PropsSI
|
|
8
|
+
_HAS_COOLPROP = True
|
|
9
|
+
except ImportError:
|
|
10
|
+
_HAS_COOLPROP = False
|
|
11
|
+
|
|
6
12
|
|
|
7
13
|
class NG_Boiler_Efficiency:
|
|
8
14
|
"""
|
|
9
15
|
EN12952-15 / EN12953-11 indirect method boiler efficiency calculator.
|
|
10
16
|
Computes heat losses (flue gas sensible, CO, radiation, condensation)
|
|
11
17
|
and derives LHV/HHV efficiencies for natural gas boilers.
|
|
18
|
+
Uses CoolProp for precise gas enthalpies when available.
|
|
12
19
|
"""
|
|
13
20
|
|
|
14
21
|
R = 8.314510 # J/mol/K
|
|
@@ -19,8 +26,11 @@ class NG_Boiler_Efficiency:
|
|
|
19
26
|
# Dry air molar composition
|
|
20
27
|
DRY_AIR = {'CO2': 0.00033, 'O2': 0.20946, 'N2': 0.78102, 'Ar': 0.00919}
|
|
21
28
|
|
|
22
|
-
#
|
|
23
|
-
|
|
29
|
+
# CoolProp fluid names
|
|
30
|
+
_CP_NAMES = {'CO2': 'CarbonDioxide', 'N2': 'Nitrogen', 'O2': 'Oxygen', 'Ar': 'Argon'}
|
|
31
|
+
|
|
32
|
+
# Fallback Cp in kJ/Nm3/K (if CoolProp unavailable)
|
|
33
|
+
FG_CP_FALLBACK = {'CO2': 1.7, 'H2O': 1.5, 'N2': 1.3, 'O2': 1.3, 'Ar': 0.93}
|
|
24
34
|
|
|
25
35
|
# Radiation loss constants
|
|
26
36
|
RADIATION_CONSTANT = {'water_tube': 0.0113, 'fire_tube': 0.0072}
|
|
@@ -28,6 +38,38 @@ class NG_Boiler_Efficiency:
|
|
|
28
38
|
# CO net calorific value kJ/Nm3
|
|
29
39
|
NCV_CO = 12633.0
|
|
30
40
|
|
|
41
|
+
@staticmethod
|
|
42
|
+
def _enthalpy_Nm3(species, T_K):
|
|
43
|
+
"""Enthalpy of gas species at T_K in kJ/Nm3, relative to 0 kJ at 0°C.
|
|
44
|
+
|
|
45
|
+
Uses CoolProp if available, otherwise Cp fallback.
|
|
46
|
+
For H2O: uses CoolProp at 1 kPa (superheated vapor) to avoid phase change.
|
|
47
|
+
"""
|
|
48
|
+
rho_map = {'CO2': 1.977, 'H2O': 0.8034, 'N2': 1.250, 'O2': 1.429, 'Ar': 1.784}
|
|
49
|
+
rho = rho_map.get(species, 1.3)
|
|
50
|
+
|
|
51
|
+
if _HAS_COOLPROP and species != 'H2O':
|
|
52
|
+
cp_name = NG_Boiler_Efficiency._CP_NAMES.get(species)
|
|
53
|
+
if cp_name:
|
|
54
|
+
try:
|
|
55
|
+
h = PropsSI('H', 'T', T_K, 'P', 101325, cp_name)
|
|
56
|
+
h0 = PropsSI('H', 'T', 273.15, 'P', 101325, cp_name)
|
|
57
|
+
return (h - h0) * rho / 1000.0 # J/kg * kg/Nm3 / 1000 -> kJ/Nm3
|
|
58
|
+
except Exception:
|
|
59
|
+
pass
|
|
60
|
+
|
|
61
|
+
if _HAS_COOLPROP and species == 'H2O':
|
|
62
|
+
try:
|
|
63
|
+
h = PropsSI('H', 'T', T_K, 'P', 1000, 'Water')
|
|
64
|
+
h0 = PropsSI('H', 'T', 273.16, 'P', 1000, 'Water')
|
|
65
|
+
return (h - h0) * rho / 1000.0
|
|
66
|
+
except Exception:
|
|
67
|
+
pass
|
|
68
|
+
|
|
69
|
+
# Fallback: constant Cp
|
|
70
|
+
Cp = NG_Boiler_Efficiency.FG_CP_FALLBACK.get(species, 1.3)
|
|
71
|
+
return Cp * (T_K - 273.15)
|
|
72
|
+
|
|
31
73
|
# Latent heat of water vaporization kJ/kg at 25C
|
|
32
74
|
LATENT_HEAT_WATER = 2442.5
|
|
33
75
|
|
|
@@ -173,12 +215,17 @@ class NG_Boiler_Efficiency:
|
|
|
173
215
|
# H2O volume fraction in flue gas
|
|
174
216
|
x_H2O_fg = fg['H2O'] / fg_total
|
|
175
217
|
|
|
176
|
-
# --- 9-10. Flue gas sensible heat loss ---
|
|
177
|
-
|
|
178
|
-
|
|
179
|
-
|
|
218
|
+
# --- 9-10. Flue gas sensible heat loss (CoolProp or fallback) ---
|
|
219
|
+
T_fg_K = self.T_fg + 273.15
|
|
220
|
+
T_ref_K = self.T_ref + 273.15
|
|
221
|
+
# Enthalpy of each species at T_fg and T_ref (kJ/Nm3)
|
|
222
|
+
fg_enthalpy = 0.0 # kJ per Nm3 of fuel
|
|
223
|
+
for sp, vol in fg.items():
|
|
224
|
+
h_fg = self._enthalpy_Nm3(sp, T_fg_K)
|
|
225
|
+
h_ref = self._enthalpy_Nm3(sp, T_ref_K)
|
|
226
|
+
fg_enthalpy += vol * (h_fg - h_ref)
|
|
180
227
|
|
|
181
|
-
flue_gas_loss =
|
|
228
|
+
flue_gas_loss = fg_enthalpy * self.ng_flow / 3600.0 # kW
|
|
182
229
|
|
|
183
230
|
# CO loss
|
|
184
231
|
CO_loss = self.CO_ppm * 1e-6 * fg_flow_dry * self.NCV_CO / 3600.0 # kW
|
|
@@ -219,20 +266,30 @@ class NG_Boiler_Efficiency:
|
|
|
219
266
|
# --- 12. Boiler efficiency (indirect method) ---
|
|
220
267
|
heat_credits = self.electrical_credit + self.other_heat_credit
|
|
221
268
|
|
|
222
|
-
#
|
|
269
|
+
# Water vapor remaining after condensation (Nm3/Nm3_fuel)
|
|
270
|
+
if self.T_fg < T_condensation:
|
|
271
|
+
H2O_vapor = H2O_remaining_vapor
|
|
272
|
+
H2O_condensed = fg['H2O'] - H2O_remaining_vapor
|
|
273
|
+
else:
|
|
274
|
+
H2O_vapor = fg['H2O']
|
|
275
|
+
H2O_condensed = 0.0
|
|
276
|
+
|
|
277
|
+
H2O_vapor_kg_h = H2O_vapor * self.ng_flow * 18.015 / 22.414
|
|
278
|
+
H2O_condensed_kg_h = H2O_condensed * self.ng_flow * 18.015 / 22.414
|
|
279
|
+
|
|
280
|
+
# Condensate loss: water leaving envelope at T_fg (sensible heat)
|
|
281
|
+
condensate_loss = H2O_condensed_kg_h * 4.18 * (self.T_fg - self.T_ref) / 3600.0 # kW
|
|
282
|
+
|
|
283
|
+
# === LHV basis ===
|
|
284
|
+
# Condensation recovery = latent + sensible heat recovered
|
|
223
285
|
total_losses_LHV = flue_gas_loss + CO_loss + radiation_loss - condensation_recovery
|
|
224
286
|
efficiency_LHV = 1.0 - total_losses_LHV / (Q_ng_LHV + heat_credits) if (Q_ng_LHV + heat_credits) > 0 else 0.0
|
|
225
287
|
|
|
226
|
-
# HHV basis
|
|
227
|
-
#
|
|
228
|
-
|
|
229
|
-
|
|
230
|
-
|
|
231
|
-
H2O_vapor_kg_h = H2O_vapor_Nm3_h * 18.015 / 22.414
|
|
232
|
-
latent_loss_all_water = H2O_vapor_kg_h * self.LATENT_HEAT_WATER / 3600.0 # kW
|
|
233
|
-
|
|
234
|
-
flue_gas_loss_HHV = flue_gas_loss + latent_loss_all_water
|
|
235
|
-
total_losses_HHV = flue_gas_loss_HHV + CO_loss + radiation_loss - condensation_recovery
|
|
288
|
+
# === HHV basis ===
|
|
289
|
+
# Flue gas loss includes latent heat of water REMAINING as vapor
|
|
290
|
+
latent_vapor = H2O_vapor_kg_h * self.LATENT_HEAT_WATER / 3600.0 # kW
|
|
291
|
+
flue_gas_loss_HHV = flue_gas_loss + latent_vapor
|
|
292
|
+
total_losses_HHV = flue_gas_loss_HHV + CO_loss + radiation_loss + condensate_loss
|
|
236
293
|
efficiency_HHV = 1.0 - total_losses_HHV / (Q_ng_HHV + heat_credits) if (Q_ng_HHV + heat_credits) > 0 else 0.0
|
|
237
294
|
|
|
238
295
|
# --- 13. Useful heat ---
|
|
@@ -1,6 +1,6 @@
|
|
|
1
1
|
Metadata-Version: 2.4
|
|
2
2
|
Name: energysystemmodels
|
|
3
|
-
Version:
|
|
3
|
+
Version: 20260416007
|
|
4
4
|
Summary: Energy systems models are the mathematical models that are developed in order to represent as reliably as possible various energy-related problems.
|
|
5
5
|
Author: Zoheir HADID
|
|
6
6
|
Author-email: zoheir.hadid@gmail.com
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/AirPort/AirPort.py
RENAMED
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/AirPort/__init__.py
RENAMED
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/Coil/CoolingCoil.py
RENAMED
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/Coil/CoolingCoil_Expert.py
RENAMED
|
File without changes
|
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/Coil/CoolingCoil_Tc.py
RENAMED
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/Coil/HeatingCoil.py
RENAMED
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/Coil/HeatingCoilNUT.py
RENAMED
|
File without changes
|
|
File without changes
|
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/FreshAir/AirMix.py
RENAMED
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/FreshAir/FreshAir.py
RENAMED
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/FreshAir/__init__.py
RENAMED
|
File without changes
|
|
File without changes
|
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/GenericAHU/__init__.py
RENAMED
|
File without changes
|
|
File without changes
|
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/HeatRecovery/__init__.py
RENAMED
|
File without changes
|
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/Humidification/__init__.py
RENAMED
|
File without changes
|
|
File without changes
|
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/air_humide/__init__.py
RENAMED
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/AHU/air_humide/air_humide.py
RENAMED
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/Distillation/Deethanizer.py
RENAMED
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/Distillation/PengRobinson.py
RENAMED
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/Distillation/__init__.py
RENAMED
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/Facture/SONALGAZ_Elec.py
RENAMED
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/Facture/SONALGAZ_gaz.py
RENAMED
|
File without changes
|
|
File without changes
|
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/Facture/coefficients_elec.json
RENAMED
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/HeatTransfer/CompositeWall.py
RENAMED
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/HeatTransfer/__init__.py
RENAMED
|
File without changes
|
|
File without changes
|
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/MeteoCiel/DJU_costic.py
RENAMED
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/NodeEditor/__init__.py
RENAMED
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/NodeEditor/nodeeditor/utils.py
RENAMED
|
File without changes
|
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/NodeEditor/tests/__init__.py
RENAMED
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/OpenWeatherMap/__init__.py
RENAMED
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/OpenWeatherMap/config.ini
RENAMED
|
File without changes
|
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/OpenWeatherMap/data.json
RENAMED
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/OpenWeatherMap/get_weather.py
RENAMED
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PV/ProductionElectriquePV.py
RENAMED
|
File without changes
|
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PinchAnalysis/PinchAnalysis.py
RENAMED
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PinchAnalysis/__init__.py
RENAMED
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/__init__.py
RENAMED
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/calc_conf.py
RENAMED
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/calc_window.py
RENAMED
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/config.ini
RENAMED
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/nodes/input.py
RENAMED
|
File without changes
|
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/nodes/output.py
RENAMED
|
File without changes
|
|
File without changes
|
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/PyqtSimulator/nodes/turbine.py
RENAMED
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Chiller.py
RENAMED
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/ThermodynamicCycles/Connect.py
RENAMED
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/src/TkinterGUI/__init__.py
RENAMED
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
|
File without changes
|
{energysystemmodels-20260416005 → energysystemmodels-20260416007}/test/test_api_diagnostic.py
RENAMED
|
File without changes
|
|
File without changes
|
|
File without changes
|