storcs 0.0.1

Sign up to get free protection for your applications and to get access to all the features.
@@ -0,0 +1,3 @@
1
+ pkg/*
2
+ *.gem
3
+ .bundle
data/Gemfile ADDED
@@ -0,0 +1,4 @@
1
+ source "http://rubygems.org"
2
+
3
+ # Specify your gem's dependencies in storcs.gemspec
4
+ gemspec
@@ -0,0 +1,47 @@
1
+ h1. Storcs
2
+
3
+ h2. Description
4
+
5
+ Storcs (STORage Calculation Service) is a gem designed to help you manage centralized storages in a datacenter. It's especially appropriate for having a unique visibility on heterogeneous datacenters where many SAN or NAS devices are used. It currently reports the following elements :
6
+ * total size, used size and free size (computed from sum of children's ones if any, recursively)
7
+ * percent_used and percent_free, based on the previous metrics
8
+ * raid type if applicable and accessible
9
+
10
+ Those calulcations are performed on a state file for each device you have. The way you generate the state file depends on the type of the storage system.
11
+
12
+ For the moment, it has only been tested on the following devices :
13
+ * IBM DS4000 series (tested with a DS3400, a DS4100, a DS4300 and a DS4500)
14
+ * Equalogic PS5000 and PS6000 series (tested with a PS5000XV and a PS6000)
15
+ * simple 'df -Pk' on Linux boxes (tested with various NAS devices)
16
+
17
+ h2. Installation
18
+
19
+ Build the gem and install it:
20
+
21
+ bc. gem build storcs.gemspec
22
+ gem install storcs-*.gem
23
+
24
+ h2. Parsers
25
+
26
+ A parser is an adapter specific to your device. Parser implementation depends on the way you retrieve your storage informations. Basically, it takes a name and a file, parse the file, and build a Storcs::Device object based on the parsed informations. For instance:
27
+
28
+ bc. parsed = Storcs::Parsers::DfNas.new("my-shiny-nas.example.com", "/path/to/df-k_output.txt")
29
+ device = parsed.device
30
+
31
+ h3. df -k
32
+
33
+ This is the simplest parser. It analyzes the output of a @df -Pk@ command on a mounted filesystem, possibly a local filesystem or a NAS attached with NFS or CIFS:
34
+
35
+ bc. df -kP |grep <mask_specific_to_your_server> > file.txt
36
+
37
+ h3. IBM DS4000 series
38
+
39
+ It parses a 'profile' text file, which can be obtained :
40
+ * by saving the file manually in the Fast Storage Manager graphical client (manual)
41
+ * by running a command on your management IP with the 'SMcli' client (automatic) :
42
+
43
+ bc. SMcli 192.0.0.15 -c 'show storagesubsystem profile;' > file.txt
44
+
45
+ h3. Equalogic PS5000 and PS6000
46
+
47
+ It parses the output of a 'show' command in the shell. Unfortunately, I wasn't able to run it remotely since my network administrator didn't allow me. So I have a script based on the "expect" tool with the @show@ command inside.
@@ -0,0 +1,2 @@
1
+ require 'bundler'
2
+ Bundler::GemHelper.install_tasks
@@ -0,0 +1,3 @@
1
+ require 'storcs/device'
2
+ require 'storcs/parsers'
3
+ require 'storcs/formatter'
@@ -0,0 +1,36 @@
1
+ module Storcs
2
+ class Device
3
+ attr_accessor :name, :children, :real_used, :real_size, :raid
4
+
5
+ def initialize(name)
6
+ @name = name
7
+ @children = []
8
+ @real_used = nil
9
+ @real_size = nil
10
+ end
11
+
12
+ def size
13
+ real_size || children.inject(0) do |memo,child|
14
+ memo + child.size
15
+ end
16
+ end
17
+
18
+ def used
19
+ real_used || children.inject(0) do |memo,child|
20
+ memo + child.used
21
+ end
22
+ end
23
+
24
+ def free
25
+ size - used
26
+ end
27
+
28
+ def percent_used
29
+ (100 * used / size).round
30
+ end
31
+
32
+ def percent_free
33
+ (100 * free / size).round
34
+ end
35
+ end
36
+ end
@@ -0,0 +1,14 @@
1
+ module Storcs
2
+ module Formatter
3
+ def pretty_size(size=nil)
4
+ size ||= self.size
5
+ units = %w(bytes Kb Mb Gb Tb Pb)
6
+ i = 0
7
+ while size >=1024 && units[i+1]
8
+ size /= 1024.0
9
+ i += 1
10
+ end
11
+ "#{"%.1f" % size}#{units[i]}"
12
+ end
13
+ end
14
+ end
@@ -0,0 +1,10 @@
1
+ require 'storcs/parsers/utils'
2
+ require 'storcs/parsers/df_nas'
3
+ require 'storcs/parsers/ibm'
4
+ require 'storcs/parsers/equalogic'
5
+
6
+ module Storcs
7
+ module Parsers
8
+ AVAILABLE_PARSERS = %w(df_nas)
9
+ end
10
+ end
@@ -0,0 +1,20 @@
1
+ module Storcs::Parsers
2
+ class DfNas
3
+ attr_accessor :device
4
+
5
+ def initialize(name,file)
6
+ @device = Storcs::Device.new(name)
7
+ parse!(File.readlines(file))
8
+ end
9
+
10
+ def parse!(content)
11
+ ary = content.map do |l|
12
+ l.split(/\s+/)
13
+ end.detect do |a|
14
+ a[1] && a[1].match(/^\d+$/)
15
+ end
16
+ @device.real_size = ary[1].to_i * 1024
17
+ @device.real_used = ary[2].to_i * 1024
18
+ end
19
+ end
20
+ end
@@ -0,0 +1,43 @@
1
+ module Storcs::Parsers
2
+ class Equalogic
3
+ include Storcs::Parsers::Utils
4
+
5
+ attr_accessor :device
6
+
7
+ def initialize(name,file)
8
+ @device = Storcs::Device.new(name)
9
+ parse!(File.readlines(file))
10
+ end
11
+
12
+ def parse!(lines)
13
+ @device.children = volumes(lines)
14
+ end
15
+
16
+ def volumes(lines)
17
+ return @volumes if @volumes
18
+ @volumes = []
19
+ current_section = nil
20
+ lines.each do |line|
21
+ line.strip!
22
+ if line.match /________ ([^_]+) ________/
23
+ current_section = $1.downcase
24
+ elsif %w(pools volumes).include?(current_section) && line.split[2].to_s.match(/^\d+$/)
25
+ if current_section == "volumes" && line.match(/^(\S+)\s+(\S+)/)
26
+ #g01-varlibnfs 50MB 0 online read-write 2 N
27
+ d = Storcs::Device.new($1)
28
+ d.real_size = parse_size($2)
29
+ d.real_used = d.real_size
30
+ @volumes << d
31
+ elsif current_section == "pools" && line.match(/(\S+)$/)
32
+ #default true 1 10 3744.01GB 43.88GB
33
+ d = Storcs::Device.new("free")
34
+ d.real_size = parse_size($1)
35
+ d.real_used = 0
36
+ @volumes << d
37
+ end
38
+ end
39
+ end
40
+ @volumes
41
+ end
42
+ end
43
+ end
@@ -0,0 +1,58 @@
1
+ module Storcs::Parsers
2
+ class Ibm
3
+ include Storcs::Parsers::Utils
4
+
5
+ attr_accessor :device
6
+
7
+ def initialize(name,file)
8
+ @device = Storcs::Device.new(name)
9
+ @lines = File.readlines(file)
10
+ parse!(@lines)
11
+ end
12
+
13
+ def parse!(content)
14
+ @device.children = arrays
15
+ end
16
+
17
+ def sections
18
+ return @sections if @sections
19
+ @sections = {}
20
+ current_section = nil
21
+ @lines.each do |line|
22
+ if line.chomp.match(/^([A-Z ]{3,}).*-------$/)
23
+ current_section = $1.downcase.to_sym
24
+ @sections[current_section] = []
25
+ elsif current_section
26
+ @sections[current_section] << line
27
+ end
28
+ end
29
+ @sections
30
+ end
31
+
32
+ def arrays
33
+ return @arrays if @arrays
34
+ @arrays = []
35
+ current_array = nil
36
+ logical_drive_list = false
37
+ sections[:arrays].map do |line|
38
+ if line.match /^ (ARRAY \d+)\s+\(RAID (\w+)\)/
39
+ current_array = Storcs::Device.new($1)
40
+ current_array.raid = $2
41
+ @arrays << current_array
42
+ elsif line.match /^\s{8,}LOGICAL DRIVE NAME/
43
+ logical_drive_list = true
44
+ elsif line.match /^\s*$/
45
+ logical_drive_list = false
46
+ elsif current_array && logical_drive_list
47
+ line.gsub!(/Free Capacity/,"free")
48
+ name, raw_size = line.strip.scan(/(\S+)\s+(.+)/).first
49
+ ld = Storcs::Device.new(name)
50
+ ld.real_size = parse_size(raw_size)
51
+ ld.real_used = (name == "free" ? 0 : ld.real_size)
52
+ current_array.children << ld
53
+ end
54
+ end.compact
55
+ @arrays
56
+ end
57
+ end
58
+ end
@@ -0,0 +1,25 @@
1
+ module Storcs
2
+ module Parsers
3
+ module Utils
4
+ def parse_size(line)
5
+ size = line.gsub(/[^a-z0-9().,]/i, '') #1,234 and 1 234 => 1234 + sanitizes some awful chars
6
+ if size.tr(",.","").match(/(\d+)Bytes\)/)
7
+ return $1.to_i
8
+ end
9
+ size.gsub!(/\(.*/,"")
10
+ units = %w(KB MB GB TB PB)
11
+ #let's try to guess the format :/
12
+ size.gsub!(",","") if size.include?(",") && size.include?(".")
13
+ size.gsub!(",","") if size.scan(",").length > 1
14
+ size.gsub!(",",".")
15
+ num = size.to_f
16
+ units.each_with_index do |u,idx|
17
+ if size.include?(u)
18
+ num = num * 1024 ** (idx+1)
19
+ end
20
+ end
21
+ num.round
22
+ end
23
+ end
24
+ end
25
+ end
@@ -0,0 +1,3 @@
1
+ module Storcs
2
+ VERSION = "0.0.1"
3
+ end
@@ -0,0 +1,2 @@
1
+ Filesystem 1M-blocks Used Available Use% Mounted on
2
+ 192.168.0.1:/mnt/vol0 795481 598024 197457 76% /mnt/server/vol0
@@ -0,0 +1,869 @@
1
+ PROFILE FOR STORAGE SUBSYSTEM: SAN01 (16/03/10 09:49:55)
2
+
3
+
4
+ SUMMARY------------------------------
5
+
6
+ Number of controllers: 2
7
+
8
+ Number of logical drive groups: 1
9
+
10
+ Total number of logical drives used: 3
11
+ Number of standard logical drives: 2
12
+ Number of access logical drives: 1
13
+ Total number of logical drives allowed: 256
14
+
15
+
16
+ Number of drives: 10
17
+ Mixed drive types: Enabled
18
+ Current drive type(s): Serial Attached SCSI (SAS) (10)
19
+ Total hot spare drives: 1
20
+ Standby: 1
21
+ In use: 0
22
+
23
+ Number of drive enclosures: 0
24
+ Number of drive enclosures allowed: 0
25
+
26
+ Storage Partitioning: Enabled
27
+ Number of partitions used: 1
28
+ Number of partitions allowed: 2
29
+ Number of logical drives allowed per partition: 32
30
+
31
+ Access logical drive: LUN 30,31 (see Mappings section for details)
32
+ Default host OS: W2KNET0 (Host OS index 0)
33
+
34
+ Current configuration
35
+ Firmware version: 06
36
+ NVSRAM version: N
37
+ Pending configuration
38
+ Staged firmware download supported: Yes
39
+ Firmware version: None
40
+ NVSRAM version: None
41
+ Transferred on: None
42
+ Controller enclosure audible alarm: Disabled
43
+
44
+ NVSRAM configured for batteries: Yes
45
+
46
+ Start cache flushing at (in percentage): 80
47
+ Stop cache flushing at (in percentage): 80
48
+ Cache block size (in KB): 4
49
+
50
+ Media scan frequency (in days): 30
51
+
52
+ Failover alert delay (in minutes): 5
53
+
54
+ Feature enable identifier: 33
55
+
56
+ Feature pack: Basic
57
+ Feature pack submodel ID: 40
58
+
59
+ Storage Subsystem world-wide identifier (ID): 600A
60
+
61
+ CONTROLLERS------------------------------
62
+ Number of controllers: 2
63
+
64
+ Controller in Enclosure 85, Slot A
65
+
66
+ Status: Online
67
+ Current configuration
68
+ Firmware version: 0.22.00
69
+ Appware version: 0.22.00
70
+ Bootware version: 0.22.00
71
+ NVSRAM version: N
72
+ Pending configuration
73
+ Firmware version: None
74
+ Appware version: None
75
+ Bootware version: None
76
+ NVSRAM version: None
77
+ Transferred on: None
78
+ Replacement part number: 39R6502
79
+ Board ID: 1932
80
+ Submodel ID: 40
81
+ Product ID: 1726-4xx FAStT
82
+ Product revision: 0617
83
+ Serial number: SX81432585
84
+ Date of manufacture: 9 avril 2008
85
+ Cache
86
+ Total data cache: 368 MB
87
+ Processor cache: 144 MB
88
+ Host Interface Board
89
+ Board ID: 0901
90
+ Host card status: Optimal
91
+ Serial number:
92
+ Date of manufacture: Not available
93
+ Part number:
94
+ Vendor:
95
+
96
+ Associated Logical Drives (* = Preferred Owner):
97
+ SAN01_LUN1*
98
+
99
+ Controller host name: target
100
+ Remote login: Enabled*
101
+
102
+ Ethernet port: 1
103
+ MAC address: 00:30
104
+ Network configuration: Static
105
+ IP address: 192.168.129.5
106
+ Subnet mask: 255.255.255.0
107
+ Gateway: 192.168.129.1
108
+
109
+ *NVSRAM setting, may be overridden by DHCP/Bootp server setting
110
+
111
+ Drive interface: SAS
112
+ Channel: 1
113
+ Port: Expansion
114
+ Status: Up
115
+ Maximum data rate: 3 Gbps
116
+ Current data rate: 3 Gbps
117
+ Drive interface: SAS
118
+ Channel: 2
119
+ Port: Expansion
120
+ Status: Up
121
+ Maximum data rate: 3 Gbps
122
+ Current data rate: 3 Gbps
123
+ Host interface: Fibre
124
+ Channel: 1
125
+ Current ID: 125/0x1
126
+ Preferred ID: 125/0x1
127
+ NL-Port ID: 0x000001
128
+ Maximum data rate: 4 Gbps
129
+ Current data rate: 4 Gbps
130
+ Data rate control: Auto
131
+ Link status: Up
132
+ Topology: Arbitrated Loop - Private
133
+ World-wide port identifier: 20:24:00:30
134
+ World-wide node identifier: 20:04:00:30
135
+ Part type: HPFC-5700 revision 5
136
+ Host interface: Fibre
137
+ Channel: 2
138
+ Current ID: Not applicable/0xFFFFFFFF
139
+ Preferred ID: 1/0xE8
140
+ NL-Port ID: 0xFFFFFF
141
+ Maximum data rate: 4 Gbps
142
+ Current data rate: 4 Gbps
143
+ Data rate control: Auto
144
+ Link status: Down
145
+ Topology: Not available
146
+ World-wide port identifier: 20:34:00:30
147
+ World-wide node identifier: 20:04:00:30
148
+ Part type: HPFC-5700 revision 5
149
+
150
+ Controller in Enclosure 85, Slot B
151
+
152
+ Status: Online
153
+ Current configuration
154
+ Firmware version: 0.22.00
155
+ Appware version: 0.22.00
156
+ Bootware version: 0.22.00
157
+ NVSRAM version: N
158
+ Pending configuration
159
+ Firmware version: None
160
+ Appware version: None
161
+ Bootware version: None
162
+ NVSRAM version: None
163
+ Transferred on: None
164
+ Replacement part number: 39R6502
165
+ Board ID: 1932
166
+ Submodel ID: 40
167
+ Product ID: 1726-4xx FAStT
168
+ Product revision: 0617
169
+ Serial number: S
170
+ Date of manufacture: 9 avril 2008
171
+ Cache
172
+ Total data cache: 368 MB
173
+ Processor cache: 144 MB
174
+ Host Interface Board
175
+ Board ID: 0901
176
+ Host card status: Optimal
177
+ Serial number:
178
+ Date of manufacture: Not available
179
+ Part number:
180
+ Vendor:
181
+
182
+ Associated Logical Drives (* = Preferred Owner):
183
+ SAN01_LUN2*
184
+
185
+ Controller host name: target
186
+ Remote login: Enabled*
187
+
188
+ Ethernet port: 1
189
+ MAC address: 00:0a
190
+ Network configuration: Static
191
+ IP address: 192.168.129.15
192
+ Subnet mask: 255.255.255.0
193
+ Gateway: 192.168.129.1
194
+
195
+ *NVSRAM setting, may be overridden by DHCP/Bootp server setting
196
+
197
+ Drive interface: SAS
198
+ Channel: 1
199
+ Port: Expansion
200
+ Status: Up
201
+ Maximum data rate: 3 Gbps
202
+ Current data rate: 3 Gbps
203
+ Drive interface: SAS
204
+ Channel: 2
205
+ Port: Expansion
206
+ Status: Up
207
+ Maximum data rate: 3 Gbps
208
+ Current data rate: 3 Gbps
209
+
210
+ Host Interface(s): Unable to retrieve latest data; using last known state.
211
+
212
+ Host interface: Fibre
213
+ Channel: 1
214
+ Current ID: 2/0xE4
215
+ Preferred ID: 2/0xE4
216
+ NL-Port ID: 0x0000E4
217
+ Maximum data rate: 4 Gbps
218
+ Current data rate: 4 Gbps
219
+ Data rate control: Auto
220
+ Link status: Up
221
+ Topology: Arbitrated Loop - Private
222
+ World-wide port identifier: 20:25:00:30
223
+ World-wide node identifier: 20:04:00:30
224
+ Part type: HPFC-5700 revision 5
225
+ Host interface: Fibre
226
+ Channel: 2
227
+ Current ID: Not applicable/0xFFFFFFFF
228
+ Preferred ID: 3/0xE2
229
+ NL-Port ID: 0xFFFFFF
230
+ Maximum data rate: 4 Gbps
231
+ Current data rate: 4 Gbps
232
+ Data rate control: Auto
233
+ Link status: Down
234
+ Topology: Not available
235
+ World-wide port identifier: 20:35:00:30
236
+ World-wide node identifier: 20:04:00:30
237
+ Part type: HPFC-5700 revision 5
238
+
239
+ ARRAYS------------------------------
240
+
241
+ Number of logical drive groups: 1
242
+
243
+ ARRAY 1 (RAID 5)
244
+
245
+ Array status: Online
246
+
247
+ Drive type: Serial Attached SCSI (SAS)
248
+ Enclosure loss protection: No
249
+
250
+ Current owner: Controller in slot A,B
251
+
252
+ Associated logical drives and free capacities:
253
+
254
+ LOGICAL DRIVE NAME CAPACITY
255
+ SAN01_LUN1 1 024 GB
256
+ SAN01_LUN2 1 207,172 GB
257
+
258
+ Associated drives (in piece order):
259
+
260
+ ENCLOSURE SLOT
261
+ 85 2
262
+ 85 3
263
+ 85 4
264
+ 85 5
265
+ 85 6
266
+ 85 7
267
+ 85 9
268
+ 85 10
269
+ 85 11
270
+
271
+ STANDARD LOGICAL DRIVES------------------------------
272
+
273
+ SUMMARY
274
+
275
+ Number of standard logical drives: 2
276
+
277
+ See other Logical Drives sub-tabs for premium feature information.
278
+
279
+ NAME STATUS CAPACITY RAID LEVEL ARRAY DRIVE TYPE
280
+ SAN01_LUN1 Optimal 1 024 GB 5 1 SAS
281
+ SAN01_LUN2 Optimal 1 207,172 GB 5 1 SAS
282
+
283
+ DETAILS
284
+
285
+ LOGICAL DRIVE NAME: SAN01_LUN1
286
+
287
+ Logical Drive status: Optimal
288
+
289
+ Capacity: 1 024 GB (1 099 511 627 776 Bytes)
290
+ Logical Drive ID: 60:00
291
+ Subsystem ID (SSID): 0
292
+ Associated array: 1
293
+ RAID level: 5
294
+
295
+ Drive type: Serial Attached SCSI (SAS)
296
+ Enclosure loss protection: No
297
+
298
+ Preferred owner: Controller in slot A
299
+ Current owner: Controller in slot A
300
+
301
+ Segment size: 128 KB
302
+ Modification priority: High
303
+
304
+ Read cache: Enabled
305
+ Write cache: Enabled
306
+ Write cache without batteries: Disabled
307
+ Write cache with mirroring: Enabled
308
+ Flush write cache after (in seconds): 10.00
309
+ Dynamic cache read prefetch: Enabled
310
+
311
+ Enable background media scan: Enabled
312
+ Media scan with redundancy check: Disabled
313
+
314
+ LOGICAL DRIVE NAME: SAN01_LUN2
315
+
316
+ Logical Drive status: Optimal
317
+
318
+ Capacity: 1 207,172 GB (1 296 190 930 944 Bytes)
319
+ Logical Drive ID: 60:85
320
+ Subsystem ID (SSID): 1
321
+ Associated array: 1
322
+ RAID level: 5
323
+
324
+ Drive type: Serial Attached SCSI (SAS)
325
+ Enclosure loss protection: No
326
+
327
+ Preferred owner: Controller in slot B
328
+ Current owner: Controller in slot B
329
+
330
+ Segment size: 128 KB
331
+ Modification priority: High
332
+
333
+ Read cache: Enabled
334
+ Write cache: Enabled
335
+ Write cache without batteries: Disabled
336
+ Write cache with mirroring: Enabled
337
+ Flush write cache after (in seconds): 10.00
338
+ Dynamic cache read prefetch: Enabled
339
+
340
+ Enable background media scan: Enabled
341
+ Media scan with redundancy check: Disabled
342
+
343
+ MISSING LOGICAL DRIVES------------------------------
344
+
345
+ Number of missing logical drives: 0
346
+
347
+ DRIVES------------------------------
348
+
349
+ SUMMARY
350
+ Number of drives: 10
351
+ Current drive types: Serial Attached SCSI (SAS) (10)
352
+
353
+ BASIC:
354
+ TRAY, SLOT STATUS CAPACITY TYPE CURRENT DATA RATE PRODUCT ID FIRMWARE VERSION
355
+ 85, 1 Optimal 279,397 GB SAS 3 Gbps ST3300655SS BA28
356
+ 85, 2 Optimal 279,397 GB SAS 3 Gbps MBA3300RC SA05
357
+ 85, 3 Optimal 279,397 GB SAS 3 Gbps MBA3300RC SA05
358
+ 85, 4 Optimal 279,397 GB SAS 3 Gbps ST3300655SS BA28
359
+ 85, 5 Optimal 279,397 GB SAS 3 Gbps MBA3300RC SA05
360
+ 85, 6 Optimal 279,397 GB SAS 3 Gbps MBA3300RC SA05
361
+ 85, 7 Optimal 279,397 GB SAS 3 Gbps MBA3300RC SA05
362
+ 85, 9 Optimal 279,397 GB SAS 3 Gbps ST3300655SS BA28
363
+ 85, 10 Optimal 279,397 GB SAS 3 Gbps MBA3300RC SA05
364
+ 85, 11 Optimal 279,397 GB SAS 3 Gbps MBA3300RC SA05
365
+
366
+ DRIVE CHANNELS:
367
+ TRAY, SLOT PREFERRED CHANNEL REDUNDANT CHANNEL
368
+ 85, 1 1 2
369
+ 85, 2 2 1
370
+ 85, 3 1 2
371
+ 85, 4 2 1
372
+ 85, 5 1 2
373
+ 85, 6 2 1
374
+ 85, 7 1 2
375
+ 85, 9 1 2
376
+ 85, 10 2 1
377
+ 85, 11 1 2
378
+
379
+
380
+ HOT SPARE COVERAGE:
381
+ The following logical drive groups are not protected: None - All logical drive groups are protected
382
+ Total hot spare drives: 1
383
+ Standby: 1
384
+ In use: 0
385
+
386
+ Standby drive at enclosure 85, slot 1 (SAS, 279,397 GB)
387
+ Protects the following logical drive groups: 1
388
+
389
+
390
+ DETAILS
391
+ Drive at Enclosure 85, Slot 1
392
+
393
+ Status: Optimal
394
+
395
+ Mode: Hot spare standby
396
+ Raw capacity: 279,397 GB
397
+ Usable capacity: 278,897 GB
398
+ World-wide identifier: 50:00:c5:00:0b:cb:e0:e7
399
+ Associated array: None
400
+
401
+ PORT CHANNEL
402
+ 0 1
403
+ 1 2
404
+
405
+ Drive path redundancy: OK
406
+ Drive type: Serial Attached SCSI (SAS)
407
+
408
+ Speed: 15015 RPM
409
+ Current data rate: 3 Gbps
410
+ Product ID: ST3300655SS
411
+ Firmware version: BA28
412
+ Serial number: 3LM5E5YF00009904BQZ5
413
+ Vendor: IBM-ESXS
414
+ Date of manufacture: Not available
415
+
416
+ Drive at Enclosure 85, Slot 2
417
+
418
+ Status: Optimal
419
+
420
+ Mode: Assigned
421
+ Raw capacity: 279,397 GB
422
+ Usable capacity: 278,897 GB
423
+ World-wide identifier: 50:00:00:e0:1c:99:25:70
424
+ Associated array: 1
425
+
426
+ PORT CHANNEL
427
+ 0 2
428
+ 1 1
429
+
430
+ Drive path redundancy: OK
431
+ Drive type: Serial Attached SCSI (SAS)
432
+
433
+ Speed: 15000 RPM
434
+ Current data rate: 3 Gbps
435
+ Product ID: MBA3300RC
436
+ Firmware version: SA05
437
+ Serial number: BJ59P8801L0S
438
+ Vendor: IBM-ESXS
439
+ Date of manufacture: Not available
440
+
441
+ Drive at Enclosure 85, Slot 3
442
+
443
+ Status: Optimal
444
+
445
+ Mode: Assigned
446
+ Raw capacity: 279,397 GB
447
+ Usable capacity: 278,897 GB
448
+ World-wide identifier: 50:00:00:e0:1c:96:0d:30
449
+ Associated array: 1
450
+
451
+ PORT CHANNEL
452
+ 0 1
453
+ 1 2
454
+
455
+ Drive path redundancy: OK
456
+ Drive type: Serial Attached SCSI (SAS)
457
+
458
+ Speed: 15000 RPM
459
+ Current data rate: 3 Gbps
460
+ Product ID: MBA3300RC
461
+ Firmware version: SA05
462
+ Serial number: BJ59P8801K4Y
463
+ Vendor: IBM-ESXS
464
+ Date of manufacture: Not available
465
+
466
+ Drive at Enclosure 85, Slot 4
467
+
468
+ Status: Optimal
469
+
470
+ Mode: Assigned
471
+ Raw capacity: 279,397 GB
472
+ Usable capacity: 278,897 GB
473
+ World-wide identifier: 50:00:c5:00:0b:cb:de:ff
474
+ Associated array: 1
475
+
476
+ PORT CHANNEL
477
+ 0 2
478
+ 1 1
479
+
480
+ Drive path redundancy: OK
481
+ Drive type: Serial Attached SCSI (SAS)
482
+
483
+ Speed: 15015 RPM
484
+ Current data rate: 3 Gbps
485
+ Product ID: ST3300655SS
486
+ Firmware version: BA28
487
+ Serial number: 3LM5E5TC00009905D8Z2
488
+ Vendor: IBM-ESXS
489
+ Date of manufacture: Not available
490
+
491
+ Drive at Enclosure 85, Slot 5
492
+
493
+ Status: Optimal
494
+
495
+ Mode: Assigned
496
+ Raw capacity: 279,397 GB
497
+ Usable capacity: 278,897 GB
498
+ World-wide identifier: 50:00:00:e0:1c:99:25:10
499
+ Associated array: 1
500
+
501
+ PORT CHANNEL
502
+ 0 1
503
+ 1 2
504
+
505
+ Drive path redundancy: OK
506
+ Drive type: Serial Attached SCSI (SAS)
507
+
508
+ Speed: 15000 RPM
509
+ Current data rate: 3 Gbps
510
+ Product ID: MBA3300RC
511
+ Firmware version: SA05
512
+ Serial number: BJ59P8801L0M
513
+ Vendor: IBM-ESXS
514
+ Date of manufacture: Not available
515
+
516
+ Drive at Enclosure 85, Slot 6
517
+
518
+ Status: Optimal
519
+
520
+ Mode: Assigned
521
+ Raw capacity: 279,397 GB
522
+ Usable capacity: 278,897 GB
523
+ World-wide identifier: 50:00:00:e0:1c:95:db:70
524
+ Associated array: 1
525
+
526
+ PORT CHANNEL
527
+ 0 2
528
+ 1 1
529
+
530
+ Drive path redundancy: OK
531
+ Drive type: Serial Attached SCSI (SAS)
532
+
533
+ Speed: 15000 RPM
534
+ Current data rate: 3 Gbps
535
+ Product ID: MBA3300RC
536
+ Firmware version: SA05
537
+ Serial number: BJ59P8801K3M
538
+ Vendor: IBM-ESXS
539
+ Date of manufacture: Not available
540
+
541
+ Drive at Enclosure 85, Slot 7
542
+
543
+ Status: Optimal
544
+
545
+ Mode: Assigned
546
+ Raw capacity: 279,397 GB
547
+ Usable capacity: 278,897 GB
548
+ World-wide identifier: 50:00:00:e0:1c:99:25:80
549
+ Associated array: 1
550
+
551
+ PORT CHANNEL
552
+ 0 1
553
+ 1 2
554
+
555
+ Drive path redundancy: OK
556
+ Drive type: Serial Attached SCSI (SAS)
557
+
558
+ Speed: 15000 RPM
559
+ Current data rate: 3 Gbps
560
+ Product ID: MBA3300RC
561
+ Firmware version: SA05
562
+ Serial number: BJ59P8801L0T
563
+ Vendor: IBM-ESXS
564
+ Date of manufacture: Not available
565
+
566
+ Drive at Enclosure 85, Slot 9
567
+
568
+ Status: Optimal
569
+
570
+ Mode: Assigned
571
+ Raw capacity: 279,397 GB
572
+ Usable capacity: 278,897 GB
573
+ World-wide identifier: 50:00:c5:00:0b:c9:96:2b
574
+ Associated array: 1
575
+
576
+ PORT CHANNEL
577
+ 0 1
578
+ 1 2
579
+
580
+ Drive path redundancy: OK
581
+ Drive type: Serial Attached SCSI (SAS)
582
+
583
+ Speed: 15015 RPM
584
+ Current data rate: 3 Gbps
585
+ Product ID: ST3300655SS
586
+ Firmware version: BA28
587
+ Serial number: 3LM5DY2V00009904YK44
588
+ Vendor: IBM-ESXS
589
+ Date of manufacture: Not available
590
+
591
+ Drive at Enclosure 85, Slot 10
592
+
593
+ Status: Optimal
594
+
595
+ Mode: Assigned
596
+ Raw capacity: 279,397 GB
597
+ Usable capacity: 278,897 GB
598
+ World-wide identifier: 50:00:00:e0:1c:96:0e:a0
599
+ Associated array: 1
600
+
601
+ PORT CHANNEL
602
+ 0 2
603
+ 1 1
604
+
605
+ Drive path redundancy: OK
606
+ Drive type: Serial Attached SCSI (SAS)
607
+
608
+ Speed: 15000 RPM
609
+ Current data rate: 3 Gbps
610
+ Product ID: MBA3300RC
611
+ Firmware version: SA05
612
+ Serial number: BJ59P8801K53
613
+ Vendor: IBM-ESXS
614
+ Date of manufacture: Not available
615
+
616
+ Drive at Enclosure 85, Slot 11
617
+
618
+ Status: Optimal
619
+
620
+ Mode: Assigned
621
+ Raw capacity: 279,397 GB
622
+ Usable capacity: 278,897 GB
623
+ World-wide identifier: 50:00:00:e0:1c:95:c2:b0
624
+ Associated array: 1
625
+
626
+ PORT CHANNEL
627
+ 0 1
628
+ 1 2
629
+
630
+ Drive path redundancy: OK
631
+ Drive type: Serial Attached SCSI (SAS)
632
+
633
+ Speed: 15000 RPM
634
+ Current data rate: 3 Gbps
635
+ Product ID: MBA3300RC
636
+ Firmware version: SA05
637
+ Serial number: BJ59P8801K2F
638
+ Vendor: IBM-ESXS
639
+ Date of manufacture: Not available
640
+
641
+ DRIVE CHANNELS----------------------------
642
+
643
+ SUMMARY
644
+
645
+ CHANNEL PORT STATUS
646
+ 1 Optimal
647
+ 2 Optimal
648
+
649
+ DETAILS
650
+
651
+ DRIVE CHANNEL 1
652
+
653
+ Port:
654
+ Status: Optimal
655
+ Max. Rate: 3 Gbps
656
+ Current Rate: 3 Gbps
657
+ Rate Control: Switched
658
+ DRIVE COUNTS
659
+
660
+ Total # of attached drives: 10
661
+ Connected to: Controller A
662
+ Attached drives: 10
663
+ Drive enclosure: 85 (10 drives)
664
+
665
+
666
+ CUMULATIVE ERROR COUNTS
667
+
668
+ Controller A
669
+ Baseline time set: 16/03/10 10:19:01
670
+ Sample period (hh:mm:ss): 00:00:00
671
+ Controller detected errors: 0
672
+ Drive detected errors: 7
673
+ Timeout errors: 0
674
+ Total I/O count: 218848647
675
+
676
+ Controller B
677
+ Baseline time set: 16/03/10 10:19:01
678
+ Sample period (hh:mm:ss): 00:00:00
679
+ Controller detected errors: 0
680
+ Drive detected errors: 0
681
+ Timeout errors: 0
682
+ Total I/O count: 0
683
+
684
+ DRIVE CHANNEL 2
685
+
686
+ Port:
687
+ Status: Optimal
688
+ Max. Rate: 3 Gbps
689
+ Current Rate: 3 Gbps
690
+ Rate Control: Switched
691
+ DRIVE COUNTS
692
+
693
+ Total # of attached drives: 0
694
+ Connected to: Controller B
695
+ Attached drives: 0
696
+
697
+
698
+ CUMULATIVE ERROR COUNTS
699
+
700
+ Controller A
701
+ Baseline time set: 16/03/10 10:19:01
702
+ Sample period (hh:mm:ss): 00:00:00
703
+ Controller detected errors: 0
704
+ Drive detected errors: 5
705
+ Timeout errors: 0
706
+ Total I/O count: 177878511
707
+
708
+ Controller B
709
+ Baseline time set: 16/03/10 10:19:01
710
+ Sample period (hh:mm:ss): 00:00:00
711
+ Controller detected errors: 0
712
+ Drive detected errors: 0
713
+ Timeout errors: 0
714
+ Total I/O count: 0
715
+
716
+ ENCLOSURES------------------------------
717
+ Controller/Drive Enclosure Overall Component Information
718
+
719
+ Enclosure audible alarm: Disabled
720
+ Current drive types: SAS
721
+ Part number: PN 39R6545
722
+ Serial number: SN 136847B
723
+ Vendor: VN IBM
724
+ Date of manufacture: 1 mai 2008
725
+
726
+ 2 Battery Packs Detected
727
+
728
+ Battery status: Optimal
729
+ Location: Controller A
730
+ Age: 676 days
731
+ Days until replacement: 43 days
732
+ Replacement part number: PN 39R6520
733
+ Serial number: SN 1Y81242428PS
734
+ Vendor: VN IBM
735
+ Date of manufacture: 1 mars 2008
736
+
737
+ Battery status: Optimal
738
+ Location: Controller B
739
+ Age: 676 days
740
+ Days until replacement: 43 days
741
+ Replacement part number: PN 39R6520
742
+ Serial number: SN 1Y81242464PS
743
+ Vendor: VN IBM
744
+ Date of manufacture: 1 mars 2008
745
+
746
+
747
+ 2 SFPs Detected
748
+
749
+ SFP status: Optimal
750
+ Attached to: Host-side of controller A
751
+ Location: Unknown
752
+ Supported data rate(s): 1 Gbps, 2 Gbps, 4 Gbps
753
+ Link length: Intermediate
754
+ Connector: LC
755
+ Transmitter type: Shortwave Laser w/o OFC
756
+ Transmission media: TM Multi-mode 50m(M5) TM Multi-mode 62.5m(M6)
757
+ IEEE company ID: 00 17 6a
758
+ Revision:
759
+ Part number: AFBR-57R5AEZ
760
+ Serial number: A90828156A
761
+ Vendor: AVAGO
762
+ Date of manufacture: 12 juillet 2008
763
+
764
+ SFP status: Optimal
765
+ Attached to: Host-side of controller B
766
+ Location: Unknown
767
+ Supported data rate(s): 1 Gbps, 2 Gbps, 4 Gbps
768
+ Link length: Intermediate
769
+ Connector: LC
770
+ Transmitter type: Shortwave Laser w/o OFC
771
+ Transmission media: TM Multi-mode 50m(M5) TM Multi-mode 62.5m(M6)
772
+ IEEE company ID: 00 17 6a
773
+ Revision:
774
+ Part number: AFBR-57R5AEZ
775
+ Serial number: A9082813X4
776
+ Vendor: AVAGO
777
+ Date of manufacture: 12 juillet 2008
778
+
779
+
780
+ 2 Power-Fan Canisters Detected
781
+
782
+ Power-fan canister (right) status: Optimal
783
+ Part number: PN 42C2140
784
+ Serial number: SN G5T081019708
785
+ Vendor: VN IBM
786
+ Date of manufacture: 1 mars 2008
787
+
788
+
789
+ Power-fan canister (left) status: Optimal
790
+ Part number: PN 42C2140
791
+ Serial number: SN G5T081019619
792
+ Vendor: VN IBM
793
+ Date of manufacture: 1 mars 2008
794
+
795
+
796
+ 2 Power Supplies Detected
797
+
798
+ Power supply status: Optimal
799
+ Location: Power supply canister (right)
800
+
801
+ Power supply status: Optimal
802
+ Location: Power supply canister (left)
803
+
804
+
805
+ 2 Fans Detected
806
+
807
+ Fan Status: Optimal
808
+ Location: Fan canister (left)
809
+
810
+ Fan Status: Optimal
811
+ Location: Fan canister (right)
812
+
813
+
814
+ 4 Temperature Sensors Detected
815
+
816
+ Temperature sensor status: Optimal
817
+ Location: Controller A
818
+
819
+ Temperature sensor status: Optimal
820
+ Location: Controller B
821
+
822
+ Temperature sensor status: Optimal
823
+ Location: Not available
824
+
825
+ Temperature sensor status: Optimal
826
+ Location: Not available
827
+
828
+
829
+
830
+ MAPPINGS (Storage Partitioning - Enabled (1 of 2 used))-------------------
831
+
832
+ VOLUME NAME LUN CONTROLLER ACCESSIBLE BY VOLUME STATUS
833
+ Access Logical Drive 30 A,B Host APPSRV1 Optimal
834
+ SAN01_LUN1 0 A Host APPSRV1 Optimal
835
+ SAN01_LUN2 1 B Host APPSRV1 Optimal
836
+ Access Logical Drive 31 A,B Storage Subsystem Optimal
837
+
838
+ TOPOLOGY DEFINITIONS
839
+
840
+ STORAGE SUBSYSTEM
841
+ Default type: W2KNETNCL0
842
+
843
+ HOST APPSRV1
844
+ Type: Linux
845
+ Alias: APPSRV10
846
+
847
+ Type: Linux
848
+ Alias: APPSRV11
849
+
850
+ NVSRAM HOST TYPE DEFINITIONS
851
+
852
+ HOST TYPE ADT STATUS ASSOCIATED INDEX
853
+ AIX Disabled 6
854
+ AIX (with Veritas DMP) Enabled 4
855
+ HP-UX Enabled 7
856
+ IBM TS SAN VCE Enabled 12
857
+ Irix Disabled 10
858
+ LNXCLVMWARE Disabled 13
859
+ Linux Disabled 5
860
+ Netware Failover Disabled 11
861
+ Solaris Disabled 8
862
+ Solaris (with Veritas DMP) Enabled 14
863
+ Unused1 Disabled 1
864
+ W2KNETNCL0 Disabled 0 (Default)
865
+ Windows 2000/Server 2003 Clustered Disabled 3
866
+ Windows 2000/Server 2003 Clustered (supports DMP) Enabled 15
867
+ Windows 2000/Server 2003 Non-Clustered Disabled 2
868
+ Windows 2000/Server 2003 Non-Clustered (supports DMP) Enabled 9
869
+