openstudio-standards 0.2.15.pre.rc1 → 0.2.15.pre.rc2
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +4 -4
- data/data/standards/OpenStudio_Standards-ashrae_90_1.xlsx +0 -0
- data/lib/openstudio-standards/standards/Standards.Space.rb +3 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +9 -9
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +75 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +9 -9
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +74 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +9 -9
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +74 -130
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +10 -10
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +73 -129
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.prototype_inputs.json +9 -9
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +416 -332
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.prototype_inputs.json +9 -9
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +416 -332
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.prototype_inputs.json +13 -13
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +74 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.prototype_inputs.json +13 -13
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +74 -2
- data/lib/openstudio-standards/version.rb +1 -1
- metadata +2 -2
checksums.yaml
CHANGED
@@ -1,7 +1,7 @@
|
|
1
1
|
---
|
2
2
|
SHA256:
|
3
|
-
metadata.gz:
|
4
|
-
data.tar.gz:
|
3
|
+
metadata.gz: c869076e549ad8d81cad4079991abbab65dd9bbff243dce88065eb3ecd002d71
|
4
|
+
data.tar.gz: b088c8b1a1386033e9739704641a400a13fa0e4b7fb5518be7edc223da2ca60a
|
5
5
|
SHA512:
|
6
|
-
metadata.gz:
|
7
|
-
data.tar.gz:
|
6
|
+
metadata.gz: 2f5805e1c695f9e8ff4012271b84596fbdcab4a0131a37b50739678af18ab4d74350c21a3e1a57c35eaf3e1c49857af082b72b36b07b4a30df5818a9d973883a
|
7
|
+
data.tar.gz: de72946c20911940af99a6088e6fc252fa88afb5be8832aab7a80a7595c14527308db63860692c8762b6ad65f66c2e47177ecf9888cc447854cb6da1a747d2e2
|
Binary file
|
@@ -1586,7 +1586,7 @@ class Standard
|
|
1586
1586
|
#
|
1587
1587
|
# @param space [OpenStudio::Model::Space] space object
|
1588
1588
|
# @param same_floor [Bool] only consider spaces on the same floor
|
1589
|
-
# @return [
|
1589
|
+
# @return [Hash] sorted hash with array of spaces and area
|
1590
1590
|
def space_get_adjacent_spaces_with_shared_wall_areas(space, same_floor = true)
|
1591
1591
|
same_floor_spaces = []
|
1592
1592
|
spaces = []
|
@@ -1621,14 +1621,14 @@ class Standard
|
|
1621
1621
|
# now sort by areas.
|
1622
1622
|
area_index = []
|
1623
1623
|
array_hash = {}
|
1624
|
-
return
|
1624
|
+
return array_hash if spaces.size.zero?
|
1625
1625
|
|
1626
1626
|
# iterate through each surface in the space
|
1627
1627
|
space.surfaces.each do |surface|
|
1628
1628
|
# get the adjacent surface in another space.
|
1629
1629
|
adj_surface = surface.adjacentSurface
|
1630
1630
|
unless adj_surface.empty?
|
1631
|
-
# go through each of the
|
1631
|
+
# go through each of the adjacent spaces to find the matching surface/space.
|
1632
1632
|
spaces.each_with_index do |other_space, index|
|
1633
1633
|
next if other_space == space
|
1634
1634
|
|
@@ -1155,21 +1155,21 @@
|
|
1155
1155
|
"pszac_oa_damper_schedule_2": null,
|
1156
1156
|
"pszac_operation_schedule_3": null,
|
1157
1157
|
"pszac_oa_damper_schedule_3": null,
|
1158
|
-
"occ_sensing_exterior_lighting_power":
|
1159
|
-
"occ_sensing_exterior_lighting_schedule":
|
1160
|
-
"nondimming_exterior_lighting_power":
|
1161
|
-
"nondimming_exterior_lighting_schedule": "
|
1158
|
+
"occ_sensing_exterior_lighting_power": null,
|
1159
|
+
"occ_sensing_exterior_lighting_schedule": null,
|
1160
|
+
"nondimming_exterior_lighting_power": 62782.82,
|
1161
|
+
"nondimming_exterior_lighting_schedule": "Always On",
|
1162
1162
|
"building_area_method_lpd": 1.0,
|
1163
1163
|
"exterior_fuel_equipment1_power": 244443.956043956,
|
1164
1164
|
"exterior_fuel_equipment1_schedule": "Large Office BLDG ELEVATORS",
|
1165
|
-
"exterior_fuel_equipment2_power":
|
1166
|
-
"exterior_fuel_equipment2_schedule": "OfficeLarge
|
1165
|
+
"exterior_fuel_equipment2_power": 1942.8,
|
1166
|
+
"exterior_fuel_equipment2_schedule": "OfficeLarge ELEV_LIGHT_FAN_SCH_24_7",
|
1167
1167
|
"main_water_heater_volume": 300.0,
|
1168
1168
|
"main_water_heater_fuel": "Natural Gas",
|
1169
1169
|
"main_water_heater_capacity": 300000.0,
|
1170
1170
|
"main_service_water_temperature": 140.0,
|
1171
1171
|
"main_service_water_flowrate_schedule": "OfficeLarge BLDG_SWH_SCH",
|
1172
|
-
"main_water_heater_space_name":
|
1172
|
+
"main_water_heater_space_name": "Mechanical_Bot_ZN_1",
|
1173
1173
|
"main_service_water_peak_flowrate": 0.58,
|
1174
1174
|
"main_off_cycle_parasitic_heat_fraction_to_tank": null,
|
1175
1175
|
"other_off_cycle_parasitic_heat_fraction_to_tank": null,
|
@@ -1177,7 +1177,7 @@
|
|
1177
1177
|
"main_service_water_temperature_at_fixture": 140.0,
|
1178
1178
|
"main_service_water_pump_head": 29891.0,
|
1179
1179
|
"main_service_water_pump_motor_efficiency": 0.3,
|
1180
|
-
"main_service_water_parasitic_fuel_consumption_rate":
|
1180
|
+
"main_service_water_parasitic_fuel_consumption_rate": 28582.08043,
|
1181
1181
|
"laundry_water_heater_volume": null,
|
1182
1182
|
"laundry_water_heater_fuel": null,
|
1183
1183
|
"laundry_water_heater_capacity": null,
|
@@ -1383,7 +1383,7 @@
|
|
1383
1383
|
"main_service_water_temperature_at_fixture": 140.0,
|
1384
1384
|
"main_service_water_pump_head": 29891.0,
|
1385
1385
|
"main_service_water_pump_motor_efficiency": 0.3,
|
1386
|
-
"main_service_water_parasitic_fuel_consumption_rate":
|
1386
|
+
"main_service_water_parasitic_fuel_consumption_rate": 7197.674699,
|
1387
1387
|
"laundry_water_heater_volume": null,
|
1388
1388
|
"laundry_water_heater_fuel": null,
|
1389
1389
|
"laundry_water_heater_capacity": null,
|
@@ -312,7 +312,7 @@
|
|
312
312
|
"ventilation_standard": "ASHRAE 62.1-1999",
|
313
313
|
"ventilation_primary_space_type": "Offices",
|
314
314
|
"ventilation_secondary_space_type": "Conference rooms",
|
315
|
-
"ventilation_per_area":
|
315
|
+
"ventilation_per_area": 0.0,
|
316
316
|
"ventilation_per_person": 20.0,
|
317
317
|
"ventilation_air_changes": null,
|
318
318
|
"minimum_total_air_changes": null,
|
@@ -341,6 +341,15 @@
|
|
341
341
|
"exhaust_availability_schedule": null,
|
342
342
|
"exhaust_flow_fraction_schedule": null,
|
343
343
|
"balanced_exhaust_fraction_schedule": null,
|
344
|
+
"manual_continuous_dimming": null,
|
345
|
+
"programmable_multilevel_dimming": null,
|
346
|
+
"multilevel_occupancy_sensors": null,
|
347
|
+
"occupancy_sensors": null,
|
348
|
+
"occupancy_sensors_with_personal_continuous_dimming": null,
|
349
|
+
"automatic_multilevel_switching_in_primary_sidelighted_areas": null,
|
350
|
+
"automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null,
|
351
|
+
"automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null,
|
352
|
+
"automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null,
|
344
353
|
"rgb": "230_196_120"
|
345
354
|
},
|
346
355
|
{
|
@@ -420,6 +429,15 @@
|
|
420
429
|
"exhaust_availability_schedule": null,
|
421
430
|
"exhaust_flow_fraction_schedule": null,
|
422
431
|
"balanced_exhaust_fraction_schedule": null,
|
432
|
+
"manual_continuous_dimming": null,
|
433
|
+
"programmable_multilevel_dimming": null,
|
434
|
+
"multilevel_occupancy_sensors": null,
|
435
|
+
"occupancy_sensors": null,
|
436
|
+
"occupancy_sensors_with_personal_continuous_dimming": null,
|
437
|
+
"automatic_multilevel_switching_in_primary_sidelighted_areas": null,
|
438
|
+
"automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null,
|
439
|
+
"automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null,
|
440
|
+
"automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null,
|
423
441
|
"rgb": "169_31_31"
|
424
442
|
},
|
425
443
|
{
|
@@ -428,7 +446,7 @@
|
|
428
446
|
"space_type": "College - Elevator Shaft",
|
429
447
|
"lighting_standard": "ASHRAE 90.1-2004",
|
430
448
|
"lighting_primary_space_type": "ElevatorCore",
|
431
|
-
"lighting_secondary_space_type":
|
449
|
+
"lighting_secondary_space_type": null,
|
432
450
|
"lighting_per_area": null,
|
433
451
|
"rcr_threshold": null,
|
434
452
|
"lighting_per_person": null,
|
@@ -487,6 +505,15 @@
|
|
487
505
|
"exhaust_availability_schedule": null,
|
488
506
|
"exhaust_flow_fraction_schedule": null,
|
489
507
|
"balanced_exhaust_fraction_schedule": null,
|
508
|
+
"manual_continuous_dimming": null,
|
509
|
+
"programmable_multilevel_dimming": null,
|
510
|
+
"multilevel_occupancy_sensors": null,
|
511
|
+
"occupancy_sensors": null,
|
512
|
+
"occupancy_sensors_with_personal_continuous_dimming": null,
|
513
|
+
"automatic_multilevel_switching_in_primary_sidelighted_areas": null,
|
514
|
+
"automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null,
|
515
|
+
"automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null,
|
516
|
+
"automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null,
|
490
517
|
"rgb": "41_31_169"
|
491
518
|
},
|
492
519
|
{
|
@@ -494,7 +521,7 @@
|
|
494
521
|
"building_type": "College",
|
495
522
|
"space_type": "College - Entrance Lobby",
|
496
523
|
"lighting_standard": "ASHRAE 90.1-2004",
|
497
|
-
"lighting_primary_space_type": "Lobby",
|
524
|
+
"lighting_primary_space_type": "Lobby - elevator",
|
498
525
|
"lighting_secondary_space_type": "General",
|
499
526
|
"lighting_per_area": 1.3,
|
500
527
|
"rcr_threshold": null,
|
@@ -566,6 +593,15 @@
|
|
566
593
|
"exhaust_availability_schedule": null,
|
567
594
|
"exhaust_flow_fraction_schedule": null,
|
568
595
|
"balanced_exhaust_fraction_schedule": null,
|
596
|
+
"manual_continuous_dimming": null,
|
597
|
+
"programmable_multilevel_dimming": null,
|
598
|
+
"multilevel_occupancy_sensors": null,
|
599
|
+
"occupancy_sensors": null,
|
600
|
+
"occupancy_sensors_with_personal_continuous_dimming": null,
|
601
|
+
"automatic_multilevel_switching_in_primary_sidelighted_areas": null,
|
602
|
+
"automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null,
|
603
|
+
"automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null,
|
604
|
+
"automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null,
|
569
605
|
"rgb": "230_157_120"
|
570
606
|
},
|
571
607
|
{
|
@@ -821,6 +857,15 @@
|
|
821
857
|
"exhaust_availability_schedule": null,
|
822
858
|
"exhaust_flow_fraction_schedule": null,
|
823
859
|
"balanced_exhaust_fraction_schedule": null,
|
860
|
+
"manual_continuous_dimming": null,
|
861
|
+
"programmable_multilevel_dimming": null,
|
862
|
+
"multilevel_occupancy_sensors": null,
|
863
|
+
"occupancy_sensors": null,
|
864
|
+
"occupancy_sensors_with_personal_continuous_dimming": null,
|
865
|
+
"automatic_multilevel_switching_in_primary_sidelighted_areas": null,
|
866
|
+
"automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null,
|
867
|
+
"automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null,
|
868
|
+
"automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null,
|
824
869
|
"rgb": "230_157_120"
|
825
870
|
},
|
826
871
|
{
|
@@ -988,6 +1033,15 @@
|
|
988
1033
|
"exhaust_availability_schedule": null,
|
989
1034
|
"exhaust_flow_fraction_schedule": null,
|
990
1035
|
"balanced_exhaust_fraction_schedule": null,
|
1036
|
+
"manual_continuous_dimming": null,
|
1037
|
+
"programmable_multilevel_dimming": null,
|
1038
|
+
"multilevel_occupancy_sensors": null,
|
1039
|
+
"occupancy_sensors": null,
|
1040
|
+
"occupancy_sensors_with_personal_continuous_dimming": null,
|
1041
|
+
"automatic_multilevel_switching_in_primary_sidelighted_areas": null,
|
1042
|
+
"automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null,
|
1043
|
+
"automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null,
|
1044
|
+
"automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null,
|
991
1045
|
"rgb": "120_230_199"
|
992
1046
|
},
|
993
1047
|
{
|
@@ -1067,6 +1121,15 @@
|
|
1067
1121
|
"exhaust_availability_schedule": null,
|
1068
1122
|
"exhaust_flow_fraction_schedule": null,
|
1069
1123
|
"balanced_exhaust_fraction_schedule": null,
|
1124
|
+
"manual_continuous_dimming": null,
|
1125
|
+
"programmable_multilevel_dimming": null,
|
1126
|
+
"multilevel_occupancy_sensors": null,
|
1127
|
+
"occupancy_sensors": null,
|
1128
|
+
"occupancy_sensors_with_personal_continuous_dimming": null,
|
1129
|
+
"automatic_multilevel_switching_in_primary_sidelighted_areas": null,
|
1130
|
+
"automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null,
|
1131
|
+
"automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null,
|
1132
|
+
"automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null,
|
1070
1133
|
"rgb": "169_169_31"
|
1071
1134
|
},
|
1072
1135
|
{
|
@@ -1298,6 +1361,15 @@
|
|
1298
1361
|
"exhaust_availability_schedule": null,
|
1299
1362
|
"exhaust_flow_fraction_schedule": null,
|
1300
1363
|
"balanced_exhaust_fraction_schedule": null,
|
1364
|
+
"manual_continuous_dimming": null,
|
1365
|
+
"programmable_multilevel_dimming": null,
|
1366
|
+
"multilevel_occupancy_sensors": null,
|
1367
|
+
"occupancy_sensors": null,
|
1368
|
+
"occupancy_sensors_with_personal_continuous_dimming": null,
|
1369
|
+
"automatic_multilevel_switching_in_primary_sidelighted_areas": null,
|
1370
|
+
"automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null,
|
1371
|
+
"automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null,
|
1372
|
+
"automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null,
|
1301
1373
|
"rgb": "41_31_169"
|
1302
1374
|
},
|
1303
1375
|
{
|
@@ -1155,21 +1155,21 @@
|
|
1155
1155
|
"pszac_oa_damper_schedule_2": null,
|
1156
1156
|
"pszac_operation_schedule_3": null,
|
1157
1157
|
"pszac_oa_damper_schedule_3": null,
|
1158
|
-
"occ_sensing_exterior_lighting_power":
|
1159
|
-
"occ_sensing_exterior_lighting_schedule":
|
1160
|
-
"nondimming_exterior_lighting_power":
|
1161
|
-
"nondimming_exterior_lighting_schedule": "
|
1158
|
+
"occ_sensing_exterior_lighting_power": null,
|
1159
|
+
"occ_sensing_exterior_lighting_schedule": null,
|
1160
|
+
"nondimming_exterior_lighting_power": 62782.82,
|
1161
|
+
"nondimming_exterior_lighting_schedule": "Always On",
|
1162
1162
|
"building_area_method_lpd": 1.0,
|
1163
1163
|
"exterior_fuel_equipment1_power": 244443.956043956,
|
1164
1164
|
"exterior_fuel_equipment1_schedule": "Large Office BLDG ELEVATORS",
|
1165
|
-
"exterior_fuel_equipment2_power":
|
1166
|
-
"exterior_fuel_equipment2_schedule": "OfficeLarge
|
1165
|
+
"exterior_fuel_equipment2_power": 1942.8,
|
1166
|
+
"exterior_fuel_equipment2_schedule": "OfficeLarge ELEV_LIGHT_FAN_SCH_24_7",
|
1167
1167
|
"main_water_heater_volume": 300.0,
|
1168
1168
|
"main_water_heater_fuel": "Natural Gas",
|
1169
1169
|
"main_water_heater_capacity": 300000.0,
|
1170
1170
|
"main_service_water_temperature": 140.0,
|
1171
1171
|
"main_service_water_flowrate_schedule": "OfficeLarge BLDG_SWH_SCH",
|
1172
|
-
"main_water_heater_space_name":
|
1172
|
+
"main_water_heater_space_name": "Mechanical_Bot_ZN_1",
|
1173
1173
|
"main_service_water_peak_flowrate": 0.58,
|
1174
1174
|
"main_off_cycle_parasitic_heat_fraction_to_tank": null,
|
1175
1175
|
"other_off_cycle_parasitic_heat_fraction_to_tank": null,
|
@@ -1177,7 +1177,7 @@
|
|
1177
1177
|
"main_service_water_temperature_at_fixture": 140.0,
|
1178
1178
|
"main_service_water_pump_head": 29891.0,
|
1179
1179
|
"main_service_water_pump_motor_efficiency": 0.3,
|
1180
|
-
"main_service_water_parasitic_fuel_consumption_rate":
|
1180
|
+
"main_service_water_parasitic_fuel_consumption_rate": 28582.08043,
|
1181
1181
|
"laundry_water_heater_volume": null,
|
1182
1182
|
"laundry_water_heater_fuel": null,
|
1183
1183
|
"laundry_water_heater_capacity": null,
|
@@ -1383,7 +1383,7 @@
|
|
1383
1383
|
"main_service_water_temperature_at_fixture": 140.0,
|
1384
1384
|
"main_service_water_pump_head": 29891.0,
|
1385
1385
|
"main_service_water_pump_motor_efficiency": 0.3,
|
1386
|
-
"main_service_water_parasitic_fuel_consumption_rate":
|
1386
|
+
"main_service_water_parasitic_fuel_consumption_rate": 7197.674699,
|
1387
1387
|
"laundry_water_heater_volume": null,
|
1388
1388
|
"laundry_water_heater_fuel": null,
|
1389
1389
|
"laundry_water_heater_capacity": null,
|
@@ -341,6 +341,15 @@
|
|
341
341
|
"exhaust_availability_schedule": null,
|
342
342
|
"exhaust_flow_fraction_schedule": null,
|
343
343
|
"balanced_exhaust_fraction_schedule": null,
|
344
|
+
"manual_continuous_dimming": null,
|
345
|
+
"programmable_multilevel_dimming": null,
|
346
|
+
"multilevel_occupancy_sensors": null,
|
347
|
+
"occupancy_sensors": null,
|
348
|
+
"occupancy_sensors_with_personal_continuous_dimming": null,
|
349
|
+
"automatic_multilevel_switching_in_primary_sidelighted_areas": null,
|
350
|
+
"automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null,
|
351
|
+
"automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null,
|
352
|
+
"automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null,
|
344
353
|
"rgb": "230_196_120"
|
345
354
|
},
|
346
355
|
{
|
@@ -420,6 +429,15 @@
|
|
420
429
|
"exhaust_availability_schedule": null,
|
421
430
|
"exhaust_flow_fraction_schedule": null,
|
422
431
|
"balanced_exhaust_fraction_schedule": null,
|
432
|
+
"manual_continuous_dimming": null,
|
433
|
+
"programmable_multilevel_dimming": null,
|
434
|
+
"multilevel_occupancy_sensors": null,
|
435
|
+
"occupancy_sensors": null,
|
436
|
+
"occupancy_sensors_with_personal_continuous_dimming": null,
|
437
|
+
"automatic_multilevel_switching_in_primary_sidelighted_areas": null,
|
438
|
+
"automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null,
|
439
|
+
"automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null,
|
440
|
+
"automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null,
|
423
441
|
"rgb": "169_31_31"
|
424
442
|
},
|
425
443
|
{
|
@@ -459,7 +477,7 @@
|
|
459
477
|
"ventilation_primary_space_type": "Public Spaces",
|
460
478
|
"ventilation_secondary_space_type": "Elevators",
|
461
479
|
"ventilation_per_area": 1.0,
|
462
|
-
"ventilation_per_person":
|
480
|
+
"ventilation_per_person": 0.0,
|
463
481
|
"ventilation_air_changes": null,
|
464
482
|
"minimum_total_air_changes": null,
|
465
483
|
"infiltration_per_exterior_area": null,
|
@@ -487,6 +505,15 @@
|
|
487
505
|
"exhaust_availability_schedule": null,
|
488
506
|
"exhaust_flow_fraction_schedule": null,
|
489
507
|
"balanced_exhaust_fraction_schedule": null,
|
508
|
+
"manual_continuous_dimming": null,
|
509
|
+
"programmable_multilevel_dimming": null,
|
510
|
+
"multilevel_occupancy_sensors": null,
|
511
|
+
"occupancy_sensors": null,
|
512
|
+
"occupancy_sensors_with_personal_continuous_dimming": null,
|
513
|
+
"automatic_multilevel_switching_in_primary_sidelighted_areas": null,
|
514
|
+
"automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null,
|
515
|
+
"automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null,
|
516
|
+
"automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null,
|
490
517
|
"rgb": "41_31_169"
|
491
518
|
},
|
492
519
|
{
|
@@ -494,7 +521,7 @@
|
|
494
521
|
"building_type": "College",
|
495
522
|
"space_type": "College - Entrance Lobby",
|
496
523
|
"lighting_standard": "ASHRAE 90.1-2007",
|
497
|
-
"lighting_primary_space_type": "Lobby",
|
524
|
+
"lighting_primary_space_type": "Lobby - elevator",
|
498
525
|
"lighting_secondary_space_type": "General",
|
499
526
|
"lighting_per_area": 1.3,
|
500
527
|
"rcr_threshold": null,
|
@@ -566,6 +593,15 @@
|
|
566
593
|
"exhaust_availability_schedule": null,
|
567
594
|
"exhaust_flow_fraction_schedule": null,
|
568
595
|
"balanced_exhaust_fraction_schedule": null,
|
596
|
+
"manual_continuous_dimming": null,
|
597
|
+
"programmable_multilevel_dimming": null,
|
598
|
+
"multilevel_occupancy_sensors": null,
|
599
|
+
"occupancy_sensors": null,
|
600
|
+
"occupancy_sensors_with_personal_continuous_dimming": null,
|
601
|
+
"automatic_multilevel_switching_in_primary_sidelighted_areas": null,
|
602
|
+
"automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null,
|
603
|
+
"automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null,
|
604
|
+
"automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null,
|
569
605
|
"rgb": "230_157_120"
|
570
606
|
},
|
571
607
|
{
|
@@ -821,6 +857,15 @@
|
|
821
857
|
"exhaust_availability_schedule": null,
|
822
858
|
"exhaust_flow_fraction_schedule": null,
|
823
859
|
"balanced_exhaust_fraction_schedule": null,
|
860
|
+
"manual_continuous_dimming": null,
|
861
|
+
"programmable_multilevel_dimming": null,
|
862
|
+
"multilevel_occupancy_sensors": null,
|
863
|
+
"occupancy_sensors": null,
|
864
|
+
"occupancy_sensors_with_personal_continuous_dimming": null,
|
865
|
+
"automatic_multilevel_switching_in_primary_sidelighted_areas": null,
|
866
|
+
"automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null,
|
867
|
+
"automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null,
|
868
|
+
"automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null,
|
824
869
|
"rgb": "230_157_120"
|
825
870
|
},
|
826
871
|
{
|
@@ -988,6 +1033,15 @@
|
|
988
1033
|
"exhaust_availability_schedule": null,
|
989
1034
|
"exhaust_flow_fraction_schedule": null,
|
990
1035
|
"balanced_exhaust_fraction_schedule": null,
|
1036
|
+
"manual_continuous_dimming": null,
|
1037
|
+
"programmable_multilevel_dimming": null,
|
1038
|
+
"multilevel_occupancy_sensors": null,
|
1039
|
+
"occupancy_sensors": null,
|
1040
|
+
"occupancy_sensors_with_personal_continuous_dimming": null,
|
1041
|
+
"automatic_multilevel_switching_in_primary_sidelighted_areas": null,
|
1042
|
+
"automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null,
|
1043
|
+
"automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null,
|
1044
|
+
"automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null,
|
991
1045
|
"rgb": "120_230_199"
|
992
1046
|
},
|
993
1047
|
{
|
@@ -1067,6 +1121,15 @@
|
|
1067
1121
|
"exhaust_availability_schedule": null,
|
1068
1122
|
"exhaust_flow_fraction_schedule": null,
|
1069
1123
|
"balanced_exhaust_fraction_schedule": null,
|
1124
|
+
"manual_continuous_dimming": null,
|
1125
|
+
"programmable_multilevel_dimming": null,
|
1126
|
+
"multilevel_occupancy_sensors": null,
|
1127
|
+
"occupancy_sensors": null,
|
1128
|
+
"occupancy_sensors_with_personal_continuous_dimming": null,
|
1129
|
+
"automatic_multilevel_switching_in_primary_sidelighted_areas": null,
|
1130
|
+
"automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null,
|
1131
|
+
"automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null,
|
1132
|
+
"automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null,
|
1070
1133
|
"rgb": "169_169_31"
|
1071
1134
|
},
|
1072
1135
|
{
|
@@ -1298,6 +1361,15 @@
|
|
1298
1361
|
"exhaust_availability_schedule": null,
|
1299
1362
|
"exhaust_flow_fraction_schedule": null,
|
1300
1363
|
"balanced_exhaust_fraction_schedule": null,
|
1364
|
+
"manual_continuous_dimming": null,
|
1365
|
+
"programmable_multilevel_dimming": null,
|
1366
|
+
"multilevel_occupancy_sensors": null,
|
1367
|
+
"occupancy_sensors": null,
|
1368
|
+
"occupancy_sensors_with_personal_continuous_dimming": null,
|
1369
|
+
"automatic_multilevel_switching_in_primary_sidelighted_areas": null,
|
1370
|
+
"automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null,
|
1371
|
+
"automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null,
|
1372
|
+
"automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null,
|
1301
1373
|
"rgb": "41_31_169"
|
1302
1374
|
},
|
1303
1375
|
{
|
@@ -44,7 +44,7 @@
|
|
44
44
|
"main_service_water_temperature_at_fixture": 140.0,
|
45
45
|
"main_service_water_pump_head": 29891.0,
|
46
46
|
"main_service_water_pump_motor_efficiency": 0.3,
|
47
|
-
"main_service_water_parasitic_fuel_consumption_rate":
|
47
|
+
"main_service_water_parasitic_fuel_consumption_rate": 27797.29,
|
48
48
|
"laundry_water_heater_volume": null,
|
49
49
|
"laundry_water_heater_fuel": null,
|
50
50
|
"laundry_water_heater_capacity": null,
|
@@ -1169,7 +1169,7 @@
|
|
1169
1169
|
"main_water_heater_capacity": 300000.0,
|
1170
1170
|
"main_service_water_temperature": 140.0,
|
1171
1171
|
"main_service_water_flowrate_schedule": "OfficeLarge BLDG_SWH_SCH",
|
1172
|
-
"main_water_heater_space_name":
|
1172
|
+
"main_water_heater_space_name": "Mechanical_Bot_ZN_1",
|
1173
1173
|
"main_service_water_peak_flowrate": 0.58,
|
1174
1174
|
"main_off_cycle_parasitic_heat_fraction_to_tank": null,
|
1175
1175
|
"other_off_cycle_parasitic_heat_fraction_to_tank": null,
|
@@ -1177,7 +1177,7 @@
|
|
1177
1177
|
"main_service_water_temperature_at_fixture": 140.0,
|
1178
1178
|
"main_service_water_pump_head": 29891.0,
|
1179
1179
|
"main_service_water_pump_motor_efficiency": 0.3,
|
1180
|
-
"main_service_water_parasitic_fuel_consumption_rate":
|
1180
|
+
"main_service_water_parasitic_fuel_consumption_rate": 27797.28777,
|
1181
1181
|
"laundry_water_heater_volume": null,
|
1182
1182
|
"laundry_water_heater_fuel": null,
|
1183
1183
|
"laundry_water_heater_capacity": null,
|
@@ -1361,9 +1361,9 @@
|
|
1361
1361
|
"pszac_oa_damper_schedule_2": null,
|
1362
1362
|
"pszac_operation_schedule_3": null,
|
1363
1363
|
"pszac_oa_damper_schedule_3": null,
|
1364
|
-
"occ_sensing_exterior_lighting_power":
|
1364
|
+
"occ_sensing_exterior_lighting_power": 7402.0,
|
1365
1365
|
"occ_sensing_exterior_lighting_schedule": "OfficeMedium Exterior_lighting_schedule_b",
|
1366
|
-
"nondimming_exterior_lighting_power":
|
1366
|
+
"nondimming_exterior_lighting_power": 519.0,
|
1367
1367
|
"nondimming_exterior_lighting_schedule": "OfficeMedium Exterior_lighting_schedule_a",
|
1368
1368
|
"building_area_method_lpd": 0.9,
|
1369
1369
|
"exterior_fuel_equipment1_power": null,
|
@@ -1376,14 +1376,14 @@
|
|
1376
1376
|
"main_service_water_temperature": 140.0,
|
1377
1377
|
"main_service_water_flowrate_schedule": "OfficeMedium BLDG_SWH_SCH",
|
1378
1378
|
"main_water_heater_space_name": "Mechanical_Bot",
|
1379
|
-
"main_service_water_peak_flowrate": 0.
|
1379
|
+
"main_service_water_peak_flowrate": 0.4945,
|
1380
1380
|
"main_off_cycle_parasitic_heat_fraction_to_tank": null,
|
1381
1381
|
"other_off_cycle_parasitic_heat_fraction_to_tank": null,
|
1382
1382
|
"main_water_use_temperature": 140.0,
|
1383
1383
|
"main_service_water_temperature_at_fixture": 140.0,
|
1384
1384
|
"main_service_water_pump_head": 29891.0,
|
1385
1385
|
"main_service_water_pump_motor_efficiency": 0.3,
|
1386
|
-
"main_service_water_parasitic_fuel_consumption_rate":
|
1386
|
+
"main_service_water_parasitic_fuel_consumption_rate": 6835.987647,
|
1387
1387
|
"laundry_water_heater_volume": null,
|
1388
1388
|
"laundry_water_heater_fuel": null,
|
1389
1389
|
"laundry_water_heater_capacity": null,
|
@@ -2597,9 +2597,9 @@
|
|
2597
2597
|
"pszac_oa_damper_schedule_2": null,
|
2598
2598
|
"pszac_operation_schedule_3": null,
|
2599
2599
|
"pszac_oa_damper_schedule_3": null,
|
2600
|
-
"occ_sensing_exterior_lighting_power":
|
2600
|
+
"occ_sensing_exterior_lighting_power": 861.3,
|
2601
2601
|
"occ_sensing_exterior_lighting_schedule": "OfficeSmall Exterior_lighting_schedule_b",
|
2602
|
-
"nondimming_exterior_lighting_power":
|
2602
|
+
"nondimming_exterior_lighting_power": 50.7,
|
2603
2603
|
"nondimming_exterior_lighting_schedule": "OfficeSmall Exterior_lighting_schedule_a",
|
2604
2604
|
"building_area_method_lpd": 0.9,
|
2605
2605
|
"exterior_fuel_equipment1_power": null,
|