logstash-input-snmp 0.1.0.beta4 → 0.1.0.beta5

Sign up to get free protection for your applications and to get access to all the features.
Files changed (309) hide show
  1. checksums.yaml +4 -4
  2. data/CHANGELOG.md +5 -0
  3. data/lib/logstash/inputs/snmp.rb +75 -12
  4. data/lib/logstash/inputs/snmp/base_client.rb +162 -0
  5. data/lib/logstash/inputs/snmp/client.rb +11 -109
  6. data/lib/logstash/inputs/snmp/clientv3.rb +139 -0
  7. data/lib/logstash/inputs/snmp/mib.rb +22 -20
  8. data/lib/mibs/ietf/ACCOUNTING-CONTROL-MIB.dic +1316 -0
  9. data/lib/mibs/ietf/ADSL-LINE-EXT-MIB.dic +1724 -0
  10. data/lib/mibs/ietf/ADSL-LINE-MIB.dic +7297 -0
  11. data/lib/mibs/ietf/ADSL-TC-MIB.dic +160 -0
  12. data/lib/mibs/ietf/ADSL2-LINE-MIB.dic +8663 -0
  13. data/lib/mibs/ietf/ADSL2-LINE-TC-MIB.dic +1462 -0
  14. data/lib/mibs/ietf/AGENTX-MIB.dic +817 -0
  15. data/lib/mibs/ietf/AGGREGATE-MIB.dic +708 -0
  16. data/lib/mibs/ietf/ALARM-MIB.dic +1734 -0
  17. data/lib/mibs/ietf/APM-MIB.dic +2870 -0
  18. data/lib/mibs/ietf/APPC-MIB.dic +8687 -0
  19. data/lib/mibs/ietf/APPLETALK-MIB.dic +4399 -0
  20. data/lib/mibs/ietf/APPLICATION-MIB.dic +3750 -0
  21. data/lib/mibs/ietf/APPN-DLUR-MIB.dic +972 -0
  22. data/lib/mibs/ietf/APPN-MIB.dic +9364 -0
  23. data/lib/mibs/ietf/APPN-TRAP-MIB.dic +664 -0
  24. data/lib/mibs/ietf/APS-MIB.dic +2430 -0
  25. data/lib/mibs/ietf/ARC-MIB.dic +552 -0
  26. data/lib/mibs/ietf/ATM-ACCOUNTING-INFORMATION-MIB.dic +816 -0
  27. data/lib/mibs/ietf/ATM-MIB.dic +4104 -0
  28. data/lib/mibs/ietf/ATM-TC-MIB.dic +914 -0
  29. data/lib/mibs/ietf/ATM2-MIB.dic +4715 -0
  30. data/lib/mibs/ietf/BFD-STD-MIB.dic +2367 -0
  31. data/lib/mibs/ietf/BFD-TC-STD-MIB.dic +202 -0
  32. data/lib/mibs/ietf/BGP4-MIB.dic +1931 -0
  33. data/lib/mibs/ietf/BLDG-HVAC-MIB.dic +812 -0
  34. data/lib/mibs/ietf/BRIDGE-MIB.dic +2257 -0
  35. data/lib/mibs/ietf/CAPWAP-BASE-MIB.dic +4128 -0
  36. data/lib/mibs/ietf/CAPWAP-DOT11-MIB.dic +482 -0
  37. data/lib/mibs/ietf/CHARACTER-MIB.dic +1140 -0
  38. data/lib/mibs/ietf/CIRCUIT-IF-MIB.dic +493 -0
  39. data/lib/mibs/ietf/CLNS-MIB.dic +1702 -0
  40. data/lib/mibs/ietf/COFFEE-POT-MIB.dic +282 -0
  41. data/lib/mibs/ietf/COPS-CLIENT-MIB.dic +1270 -0
  42. data/lib/mibs/ietf/DECNET-PHIV-MIB.dic +5837 -0
  43. data/lib/mibs/ietf/DIAL-CONTROL-MIB.dic +2139 -0
  44. data/lib/mibs/ietf/DIFFSERV-CONFIG-MIB.dic +378 -0
  45. data/lib/mibs/ietf/DIFFSERV-MIB.dic +5073 -0
  46. data/lib/mibs/ietf/DIRECTORY-SERVER-MIB.dic +1041 -0
  47. data/lib/mibs/ietf/DISMAN-EVENT-MIB.dic +3151 -0
  48. data/lib/mibs/ietf/DISMAN-EXPRESSION-MIB.dic +1716 -0
  49. data/lib/mibs/ietf/DISMAN-NSLOOKUP-MIB.dic +698 -0
  50. data/lib/mibs/ietf/DISMAN-PING-MIB.dic +2635 -0
  51. data/lib/mibs/ietf/DISMAN-SCHEDULE-MIB.dic +1744 -0
  52. data/lib/mibs/ietf/DISMAN-SCRIPT-MIB.dic +2820 -0
  53. data/lib/mibs/ietf/DISMAN-TRACEROUTE-MIB.dic +3239 -0
  54. data/lib/mibs/ietf/DLSW-MIB.dic +5635 -0
  55. data/lib/mibs/ietf/DNS-RESOLVER-MIB.dic +1765 -0
  56. data/lib/mibs/ietf/DNS-SERVER-MIB.dic +1593 -0
  57. data/lib/mibs/ietf/DOCS-BPI-MIB.dic +2634 -0
  58. data/lib/mibs/ietf/DOCS-CABLE-DEVICE-MIB.dic +5042 -0
  59. data/lib/mibs/ietf/DOCS-IETF-BPI2-MIB.dic +5478 -0
  60. data/lib/mibs/ietf/DOCS-IETF-CABLE-DEVICE-NOTIFICATION-MIB.dic +2447 -0
  61. data/lib/mibs/ietf/DOCS-IETF-QOS-MIB.dic +4886 -0
  62. data/lib/mibs/ietf/DOCS-IETF-SUBMGT-MIB.dic +1331 -0
  63. data/lib/mibs/ietf/DOCS-IF-MIB.dic +7980 -0
  64. data/lib/mibs/ietf/DOT12-IF-MIB.dic +1066 -0
  65. data/lib/mibs/ietf/DOT12-RPTR-MIB.dic +2669 -0
  66. data/lib/mibs/ietf/DOT3-EPON-MIB.dic +3297 -0
  67. data/lib/mibs/ietf/DOT3-OAM-MIB.dic +2830 -0
  68. data/lib/mibs/ietf/DS0-MIB.dic +466 -0
  69. data/lib/mibs/ietf/DS0BUNDLE-MIB.dic +468 -0
  70. data/lib/mibs/ietf/DS1-MIB.dic +4890 -0
  71. data/lib/mibs/ietf/DS3-MIB.dic +2719 -0
  72. data/lib/mibs/ietf/DSA-MIB.dic +888 -0
  73. data/lib/mibs/ietf/DSMON-MIB.dic +6177 -0
  74. data/lib/mibs/ietf/DVB-RCS-MIB.dic +5764 -0
  75. data/lib/mibs/ietf/EBN-MIB.dic +1026 -0
  76. data/lib/mibs/ietf/EFM-CU-MIB.dic +4335 -0
  77. data/lib/mibs/ietf/ENTITY-MIB.dic +2235 -0
  78. data/lib/mibs/ietf/ENTITY-SENSOR-MIB.dic +653 -0
  79. data/lib/mibs/ietf/ENTITY-STATE-MIB.dic +457 -0
  80. data/lib/mibs/ietf/ENTITY-STATE-TC-MIB.dic +260 -0
  81. data/lib/mibs/ietf/ETHER-CHIPSET-MIB.dic +787 -0
  82. data/lib/mibs/ietf/EtherLike-MIB.dic +2548 -0
  83. data/lib/mibs/ietf/FC-MGMT-MIB.dic +3465 -0
  84. data/lib/mibs/ietf/FCIP-MGMT-MIB.dic +1596 -0
  85. data/lib/mibs/ietf/FDDI-SMT73-MIB.dic +3378 -0
  86. data/lib/mibs/ietf/FIBRE-CHANNEL-FE-MIB.dic +2504 -0
  87. data/lib/mibs/ietf/FLOAT-TC-MIB.dic +128 -0
  88. data/lib/mibs/ietf/FLOW-METER-MIB.dic +3201 -0
  89. data/lib/mibs/ietf/FORCES-MIB.dic +598 -0
  90. data/lib/mibs/ietf/FR-ATM-PVC-SERVICE-IWF-MIB.dic +1601 -0
  91. data/lib/mibs/ietf/FR-MFR-MIB.dic +1351 -0
  92. data/lib/mibs/ietf/FRAME-RELAY-DTE-MIB.dic +1688 -0
  93. data/lib/mibs/ietf/FRNETSERV-MIB.dic +3940 -0
  94. data/lib/mibs/ietf/FRSLD-MIB.dic +2580 -0
  95. data/lib/mibs/ietf/Finisher-MIB.dic +1416 -0
  96. data/lib/mibs/ietf/GMPLS-LABEL-STD-MIB.dic +965 -0
  97. data/lib/mibs/ietf/GMPLS-LSR-STD-MIB.dic +693 -0
  98. data/lib/mibs/ietf/GMPLS-TC-STD-MIB.dic +180 -0
  99. data/lib/mibs/ietf/GMPLS-TE-STD-MIB.dic +2542 -0
  100. data/lib/mibs/ietf/GSMP-MIB.dic +2468 -0
  101. data/lib/mibs/ietf/HC-ALARM-MIB.dic +1050 -0
  102. data/lib/mibs/ietf/HC-PerfHist-TC-MIB.dic +310 -0
  103. data/lib/mibs/ietf/HC-RMON-MIB.dic +4456 -0
  104. data/lib/mibs/ietf/HDSL2-SHDSL-LINE-MIB.dic +3955 -0
  105. data/lib/mibs/ietf/HOST-RESOURCES-MIB.dic +2453 -0
  106. data/lib/mibs/ietf/HPR-IP-MIB.dic +640 -0
  107. data/lib/mibs/ietf/HPR-MIB.dic +1959 -0
  108. data/lib/mibs/ietf/IANA-ITU-ALARM-TC-MIB.dic +936 -0
  109. data/lib/mibs/ietf/IF-CAP-STACK-MIB.dic +356 -0
  110. data/lib/mibs/ietf/IF-INVERTED-STACK-MIB.dic +220 -0
  111. data/lib/mibs/ietf/IF-MIB.dic +2753 -0
  112. data/lib/mibs/ietf/IFCP-MGMT-MIB.dic +1717 -0
  113. data/lib/mibs/ietf/IGMP-STD-MIB.dic +809 -0
  114. data/lib/mibs/ietf/INET-ADDRESS-MIB.dic +570 -0
  115. data/lib/mibs/ietf/INTEGRATED-SERVICES-GUARANTEED-MIB.dic +319 -0
  116. data/lib/mibs/ietf/INTEGRATED-SERVICES-MIB.dic +1196 -0
  117. data/lib/mibs/ietf/INTERFACETOPN-MIB.dic +1705 -0
  118. data/lib/mibs/ietf/IP-FORWARD-MIB.dic +1853 -0
  119. data/lib/mibs/ietf/IP-MIB.dic +7064 -0
  120. data/lib/mibs/ietf/IPATM-IPMC-MIB.dic +4830 -0
  121. data/lib/mibs/ietf/IPFIX-MIB.dic +2334 -0
  122. data/lib/mibs/ietf/IPFIX-SELECTOR-MIB.dic +215 -0
  123. data/lib/mibs/ietf/IPMCAST-MIB.dic +3390 -0
  124. data/lib/mibs/ietf/IPMROUTE-STD-MIB.dic +1246 -0
  125. data/lib/mibs/ietf/IPOA-MIB.dic +2372 -0
  126. data/lib/mibs/ietf/IPS-AUTH-MIB.dic +1609 -0
  127. data/lib/mibs/ietf/IPSEC-SPD-MIB.dic +3989 -0
  128. data/lib/mibs/ietf/IPV6-FLOW-LABEL-MIB.dic +110 -0
  129. data/lib/mibs/ietf/IPV6-ICMP-MIB.dic +748 -0
  130. data/lib/mibs/ietf/IPV6-MIB.dic +2028 -0
  131. data/lib/mibs/ietf/IPV6-MLD-MIB.dic +659 -0
  132. data/lib/mibs/ietf/IPV6-TCP-MIB.dic +332 -0
  133. data/lib/mibs/ietf/IPV6-UDP-MIB.dic +209 -0
  134. data/lib/mibs/ietf/ISCSI-MIB.dic +4613 -0
  135. data/lib/mibs/ietf/ISDN-MIB.dic +1796 -0
  136. data/lib/mibs/ietf/ISIS-MIB.dic +6215 -0
  137. data/lib/mibs/ietf/ISNS-MIB.dic +6578 -0
  138. data/lib/mibs/ietf/ITU-ALARM-MIB.dic +665 -0
  139. data/lib/mibs/ietf/ITU-ALARM-TC-MIB.dic +137 -0
  140. data/lib/mibs/ietf/Job-Monitoring-MIB.dic +2519 -0
  141. data/lib/mibs/ietf/L2TP-MIB.dic +4050 -0
  142. data/lib/mibs/ietf/LANGTAG-TC-MIB.dic +104 -0
  143. data/lib/mibs/ietf/LISP-MIB.dic +4067 -0
  144. data/lib/mibs/ietf/LMP-MIB.dic +5166 -0
  145. data/lib/mibs/ietf/MALLOC-MIB.dic +2156 -0
  146. data/lib/mibs/ietf/MAU-MIB.dic +2619 -0
  147. data/lib/mibs/ietf/MIDCOM-MIB.dic +2856 -0
  148. data/lib/mibs/ietf/MIOX25-MIB.dic +828 -0
  149. data/lib/mibs/ietf/MIP-MIB.dic +3473 -0
  150. data/lib/mibs/ietf/MOBILEIPV6-MIB.dic +5228 -0
  151. data/lib/mibs/ietf/MPLS-FTN-STD-MIB.dic +1594 -0
  152. data/lib/mibs/ietf/MPLS-L3VPN-STD-MIB.dic +2548 -0
  153. data/lib/mibs/ietf/MPLS-LC-ATM-STD-MIB.dic +491 -0
  154. data/lib/mibs/ietf/MPLS-LC-FR-STD-MIB.dic +395 -0
  155. data/lib/mibs/ietf/MPLS-LDP-ATM-STD-MIB.dic +1019 -0
  156. data/lib/mibs/ietf/MPLS-LDP-FRAME-RELAY-STD-MIB.dic +862 -0
  157. data/lib/mibs/ietf/MPLS-LDP-GENERIC-STD-MIB.dic +445 -0
  158. data/lib/mibs/ietf/MPLS-LDP-STD-MIB.dic +3657 -0
  159. data/lib/mibs/ietf/MPLS-LSR-STD-MIB.dic +3103 -0
  160. data/lib/mibs/ietf/MPLS-TC-STD-MIB.dic +911 -0
  161. data/lib/mibs/ietf/MPLS-TE-STD-MIB.dic +3673 -0
  162. data/lib/mibs/ietf/MSDP-MIB.dic +1893 -0
  163. data/lib/mibs/ietf/MTA-MIB.dic +1898 -0
  164. data/lib/mibs/ietf/Modem-MIB.dic +2054 -0
  165. data/lib/mibs/ietf/NAT-MIB.dic +3866 -0
  166. data/lib/mibs/ietf/NETWORK-SERVICES-MIB.dic +1034 -0
  167. data/lib/mibs/ietf/NHDP-MIB.dic +3005 -0
  168. data/lib/mibs/ietf/NHRP-MIB.dic +3660 -0
  169. data/lib/mibs/ietf/NOTIFICATION-LOG-MIB.dic +1156 -0
  170. data/lib/mibs/ietf/NTPv4-MIB.dic +1535 -0
  171. data/lib/mibs/ietf/OPT-IF-MIB.dic +8972 -0
  172. data/lib/mibs/ietf/OSPF-MIB.dic +5963 -0
  173. data/lib/mibs/ietf/OSPF-TRAP-MIB.dic +1190 -0
  174. data/lib/mibs/ietf/OSPFV3-MIB.dic +5708 -0
  175. data/lib/mibs/ietf/P-BRIDGE-MIB.dic +1499 -0
  176. data/lib/mibs/ietf/PARALLEL-MIB.dic +476 -0
  177. data/lib/mibs/ietf/PIM-MIB.dic +1393 -0
  178. data/lib/mibs/ietf/PIM-STD-MIB.dic +6819 -0
  179. data/lib/mibs/ietf/PINT-MIB.dic +830 -0
  180. data/lib/mibs/ietf/PKTC-IETF-MTA-MIB.dic +3191 -0
  181. data/lib/mibs/ietf/PKTC-IETF-SIG-MIB.dic +4713 -0
  182. data/lib/mibs/ietf/PMIPV6-MIB.dic +3010 -0
  183. data/lib/mibs/ietf/PMIPV6-TC-MIB.dic +293 -0
  184. data/lib/mibs/ietf/POLICY-BASED-MANAGEMENT-MIB.dic +3316 -0
  185. data/lib/mibs/ietf/POWER-ETHERNET-MIB.dic +959 -0
  186. data/lib/mibs/ietf/PPP-BRIDGE-NCP-MIB.dic +587 -0
  187. data/lib/mibs/ietf/PPP-IP-NCP-MIB.dic +269 -0
  188. data/lib/mibs/ietf/PPP-LCP-MIB.dic +994 -0
  189. data/lib/mibs/ietf/PPP-SEC-MIB.dic +411 -0
  190. data/lib/mibs/ietf/PSAMP-MIB.dic +998 -0
  191. data/lib/mibs/ietf/PTOPO-MIB.dic +1135 -0
  192. data/lib/mibs/ietf/PW-ATM-MIB.dic +1642 -0
  193. data/lib/mibs/ietf/PW-CEP-STD-MIB.dic +3661 -0
  194. data/lib/mibs/ietf/PW-STD-MIB.dic +3592 -0
  195. data/lib/mibs/ietf/PW-TC-STD-MIB.dic +437 -0
  196. data/lib/mibs/ietf/PW-TDM-MIB.dic +1896 -0
  197. data/lib/mibs/ietf/PerfHist-TC-MIB.dic +152 -0
  198. data/lib/mibs/ietf/Printer-MIB.dic +6665 -0
  199. data/lib/mibs/ietf/Q-BRIDGE-MIB.dic +3115 -0
  200. data/lib/mibs/ietf/RADIUS-ACC-CLIENT-MIB.dic +991 -0
  201. data/lib/mibs/ietf/RADIUS-ACC-SERVER-MIB.dic +1183 -0
  202. data/lib/mibs/ietf/RADIUS-AUTH-CLIENT-MIB.dic +1073 -0
  203. data/lib/mibs/ietf/RADIUS-AUTH-SERVER-MIB.dic +1251 -0
  204. data/lib/mibs/ietf/RADIUS-DYNAUTH-CLIENT-MIB.dic +1116 -0
  205. data/lib/mibs/ietf/RADIUS-DYNAUTH-SERVER-MIB.dic +1003 -0
  206. data/lib/mibs/ietf/RAQMON-MIB.dic +2695 -0
  207. data/lib/mibs/ietf/RBRIDGE-MIB.dic +2981 -0
  208. data/lib/mibs/ietf/RDBMS-MIB.dic +1935 -0
  209. data/lib/mibs/ietf/RFC1065-SMI.dic +108 -0
  210. data/lib/mibs/ietf/RFC1155-SMI.dic +118 -0
  211. data/lib/mibs/ietf/RFC1158-MIB.dic +2440 -0
  212. data/lib/mibs/ietf/RFC1213-MIB.dic +3434 -0
  213. data/lib/mibs/ietf/RFC1269-MIB.dic +557 -0
  214. data/lib/mibs/ietf/RFC1271-MIB.dic +4135 -0
  215. data/lib/mibs/ietf/RFC1285-MIB.dic +2842 -0
  216. data/lib/mibs/ietf/RFC1316-MIB.dic +800 -0
  217. data/lib/mibs/ietf/RFC1381-MIB.dic +1347 -0
  218. data/lib/mibs/ietf/RFC1382-MIB.dic +3820 -0
  219. data/lib/mibs/ietf/RFC1414-MIB.dic +214 -0
  220. data/lib/mibs/ietf/RIPv2-MIB.dic +773 -0
  221. data/lib/mibs/ietf/RMON-MIB.dic +5551 -0
  222. data/lib/mibs/ietf/RMON2-MIB.dic +8224 -0
  223. data/lib/mibs/ietf/ROHC-MIB.dic +1613 -0
  224. data/lib/mibs/ietf/ROHC-RTP-MIB.dic +859 -0
  225. data/lib/mibs/ietf/ROHC-UNCOMPRESSED-MIB.dic +267 -0
  226. data/lib/mibs/ietf/RPKI-ROUTER-MIB.dic +1363 -0
  227. data/lib/mibs/ietf/RS-232-MIB.dic +1335 -0
  228. data/lib/mibs/ietf/RSERPOOL-MIB.dic +2501 -0
  229. data/lib/mibs/ietf/RSTP-MIB.dic +427 -0
  230. data/lib/mibs/ietf/RSVP-MIB.dic +4135 -0
  231. data/lib/mibs/ietf/RTP-MIB.dic +1376 -0
  232. data/lib/mibs/ietf/SCSI-MIB.dic +3804 -0
  233. data/lib/mibs/ietf/SCTP-MIB.dic +1924 -0
  234. data/lib/mibs/ietf/SFLOW-MIB.dic +568 -0
  235. data/lib/mibs/ietf/SIP-COMMON-MIB.dic +2769 -0
  236. data/lib/mibs/ietf/SIP-MIB.dic +1438 -0
  237. data/lib/mibs/ietf/SIP-SERVER-MIB.dic +1150 -0
  238. data/lib/mibs/ietf/SIP-TC-MIB.dic +257 -0
  239. data/lib/mibs/ietf/SIP-UA-MIB.dic +268 -0
  240. data/lib/mibs/ietf/SLAPM-MIB.dic +4527 -0
  241. data/lib/mibs/ietf/SMON-MIB.dic +1758 -0
  242. data/lib/mibs/ietf/SNA-NAU-MIB.dic +4042 -0
  243. data/lib/mibs/ietf/SNA-SDLC-MIB.dic +3858 -0
  244. data/lib/mibs/ietf/SNMP-COMMUNITY-MIB.dic +715 -0
  245. data/lib/mibs/ietf/SNMP-FRAMEWORK-MIB.dic +709 -0
  246. data/lib/mibs/ietf/SNMP-MPD-MIB.dic +230 -0
  247. data/lib/mibs/ietf/SNMP-NOTIFICATION-MIB.dic +859 -0
  248. data/lib/mibs/ietf/SNMP-PROXY-MIB.dic +414 -0
  249. data/lib/mibs/ietf/SNMP-REPEATER-MIB.dic +4335 -0
  250. data/lib/mibs/ietf/SNMP-SSH-TM-MIB.dic +447 -0
  251. data/lib/mibs/ietf/SNMP-TARGET-MIB.dic +924 -0
  252. data/lib/mibs/ietf/SNMP-TLS-TM-MIB.dic +1449 -0
  253. data/lib/mibs/ietf/SNMP-TSM-MIB.dic +315 -0
  254. data/lib/mibs/ietf/SNMP-USER-BASED-SM-MIB.dic +1164 -0
  255. data/lib/mibs/ietf/SNMP-USM-AES-MIB.dic +95 -0
  256. data/lib/mibs/ietf/SNMP-USM-DH-OBJECTS-MIB.dic +653 -0
  257. data/lib/mibs/ietf/SNMP-VIEW-BASED-ACM-MIB.dic +1202 -0
  258. data/lib/mibs/ietf/SNMPv2-MIB.dic +1382 -0
  259. data/lib/mibs/ietf/SNMPv2-SMI.dic +223 -0
  260. data/lib/mibs/ietf/SNMPv2-USEC-MIB.dic +405 -0
  261. data/lib/mibs/ietf/SONET-MIB.dic +3308 -0
  262. data/lib/mibs/ietf/SOURCE-ROUTING-MIB.dic +542 -0
  263. data/lib/mibs/ietf/SSPM-MIB.dic +1530 -0
  264. data/lib/mibs/ietf/SYSAPPL-MIB.dic +2092 -0
  265. data/lib/mibs/ietf/T11-FC-FABRIC-ADDR-MGR-MIB.dic +1779 -0
  266. data/lib/mibs/ietf/T11-FC-FABRIC-CONFIG-SERVER-MIB.dic +2822 -0
  267. data/lib/mibs/ietf/T11-FC-FABRIC-LOCK-MIB.dic +700 -0
  268. data/lib/mibs/ietf/T11-FC-FSPF-MIB.dic +1889 -0
  269. data/lib/mibs/ietf/T11-FC-NAME-SERVER-MIB.dic +1775 -0
  270. data/lib/mibs/ietf/T11-FC-ROUTE-MIB.dic +655 -0
  271. data/lib/mibs/ietf/T11-FC-RSCN-MIB.dic +1110 -0
  272. data/lib/mibs/ietf/T11-FC-VIRTUAL-FABRIC-MIB.dic +770 -0
  273. data/lib/mibs/ietf/T11-FC-ZONE-SERVER-MIB.dic +3886 -0
  274. data/lib/mibs/ietf/T11-TC-MIB.dic +110 -0
  275. data/lib/mibs/ietf/TCP-ESTATS-MIB.dic +3926 -0
  276. data/lib/mibs/ietf/TCP-MIB.dic +1319 -0
  277. data/lib/mibs/ietf/TCPIPX-MIB.dic +457 -0
  278. data/lib/mibs/ietf/TE-LINK-STD-MIB.dic +2876 -0
  279. data/lib/mibs/ietf/TE-MIB.dic +2924 -0
  280. data/lib/mibs/ietf/TED-MIB.dic +1749 -0
  281. data/lib/mibs/ietf/TIME-AGGREGATE-MIB.dic +550 -0
  282. data/lib/mibs/ietf/TN3270E-MIB.dic +2785 -0
  283. data/lib/mibs/ietf/TN3270E-RT-MIB.dic +1317 -0
  284. data/lib/mibs/ietf/TOKEN-RING-RMON-MIB.dic +2820 -0
  285. data/lib/mibs/ietf/TOKENRING-MIB.dic +1184 -0
  286. data/lib/mibs/ietf/TOKENRING-STATION-SR-MIB.dic +292 -0
  287. data/lib/mibs/ietf/TRANSPORT-ADDRESS-MIB.dic +610 -0
  288. data/lib/mibs/ietf/TRIP-MIB.dic +3159 -0
  289. data/lib/mibs/ietf/TRIP-TC-MIB.dic +241 -0
  290. data/lib/mibs/ietf/TUNNEL-MIB.dic +1095 -0
  291. data/lib/mibs/ietf/UDP-MIB.dic +751 -0
  292. data/lib/mibs/ietf/UDPLITE-MIB.dic +704 -0
  293. data/lib/mibs/ietf/UPS-MIB.dic +3088 -0
  294. data/lib/mibs/ietf/URI-TC-MIB.dic +193 -0
  295. data/lib/mibs/ietf/UUID-TC-MIB.dic +135 -0
  296. data/lib/mibs/ietf/VDSL-LINE-EXT-MCM-MIB.dic +989 -0
  297. data/lib/mibs/ietf/VDSL-LINE-EXT-SCM-MIB.dic +605 -0
  298. data/lib/mibs/ietf/VDSL-LINE-MIB.dic +4518 -0
  299. data/lib/mibs/ietf/VDSL2-LINE-MIB.dic +11029 -0
  300. data/lib/mibs/ietf/VDSL2-LINE-TC-MIB.dic +3152 -0
  301. data/lib/mibs/ietf/VPN-TC-STD-MIB.dic +121 -0
  302. data/lib/mibs/ietf/VRRP-MIB.dic +1163 -0
  303. data/lib/mibs/ietf/VRRPV3-MIB.dic +1403 -0
  304. data/lib/mibs/ietf/WWW-MIB.dic +1810 -0
  305. data/lib/mibs/logstash/iso.dic +18 -0
  306. data/logstash-input-snmp.gemspec +1 -1
  307. data/spec/inputs/snmp/mib_spec.rb +10 -17
  308. data/spec/inputs/snmp_spec.rb +27 -1
  309. metadata +302 -2
@@ -0,0 +1,180 @@
1
+ # python version 1.0 DO NOT EDIT
2
+ #
3
+ # This python file has been generated by smidump version 0.5.0:
4
+ #
5
+ # smidump -f python GMPLS-TC-STD-MIB
6
+
7
+ FILENAME = "./libsmi-0.5.0/mibs/ietf/GMPLS-TC-STD-MIB"
8
+
9
+ MIB = {
10
+ "moduleName" : "GMPLS-TC-STD-MIB",
11
+
12
+ "GMPLS-TC-STD-MIB" : {
13
+ "nodetype" : "module",
14
+ "language" : "SMIv2",
15
+ "organization" :
16
+ """IETF Common Control and Measurement Plane (CCAMP) Working Group""",
17
+ "contact" :
18
+ """ Thomas D. Nadeau
19
+ Cisco Systems, Inc.
20
+ Email: tnadeau@cisco.com
21
+
22
+ Adrian Farrel
23
+ Old Dog Consulting
24
+ Email: adrian@olddog.co.uk
25
+
26
+ Comments about this document should be emailed directly to the
27
+ CCAMP working group mailing list at ccamp@ops.ietf.org""",
28
+ "description" :
29
+ """Copyright (C) The IETF Trust (2007). This version of
30
+ this MIB module is part of RFC 4801; see the RFC itself for
31
+ full legal notices.
32
+
33
+ This MIB module defines TEXTUAL-CONVENTIONs for concepts used in
34
+ Generalized Multiprotocol Label Switching (GMPLS) networks.""",
35
+ "revisions" : (
36
+ {
37
+ "date" : "2007-02-28 00:00",
38
+ "description" :
39
+ """Initial version published as part of RFC 4801.""",
40
+ },
41
+ ),
42
+ "identity node" : "gmplsTCStdMIB",
43
+ },
44
+
45
+ "imports" : (
46
+ {"module" : "SNMPv2-SMI", "name" : "MODULE-IDENTITY"},
47
+ {"module" : "SNMPv2-TC", "name" : "TEXTUAL-CONVENTION"},
48
+ {"module" : "MPLS-TC-STD-MIB", "name" : "mplsStdMIB"},
49
+ ),
50
+
51
+ "typedefs" : {
52
+ "GmplsFreeformLabelTC" : {
53
+ "basetype" : "OctetString",
54
+ "status" : "current",
55
+ "ranges" : [
56
+ {
57
+ "min" : "0",
58
+ "max" : "64"
59
+ },
60
+ ],
61
+ "range" : {
62
+ "min" : "0",
63
+ "max" : "64"
64
+ },
65
+ "description" :
66
+ """This TEXTUAL-CONVENTION can be used as the syntax of an object
67
+ that contains any GMPLS Label. Objects with this syntax can be
68
+ used to represent labels that have label types that are not
69
+ defined in any RFCs. The freeform GMPLS Label may also be used
70
+ by systems that do not wish to represent labels that have
71
+ label types defined in RFCs using type-specific syntaxes.""",
72
+ "reference" :
73
+ """1. Generalized Multi-Protocol Label Switching (GMPLS) Signaling
74
+ Functional Description, RFC 3471, section 3.2.""",
75
+ },
76
+ "GmplsLabelTypeTC" : {
77
+ "basetype" : "Enumeration",
78
+ "status" : "current",
79
+ "gmplsMplsLabel" : {
80
+ "nodetype" : "namednumber",
81
+ "number" : "1"
82
+ },
83
+ "gmplsPortWavelengthLabel" : {
84
+ "nodetype" : "namednumber",
85
+ "number" : "2"
86
+ },
87
+ "gmplsFreeformGeneralizedLabel" : {
88
+ "nodetype" : "namednumber",
89
+ "number" : "3"
90
+ },
91
+ "gmplsSonetLabel" : {
92
+ "nodetype" : "namednumber",
93
+ "number" : "4"
94
+ },
95
+ "gmplsSdhLabel" : {
96
+ "nodetype" : "namednumber",
97
+ "number" : "5"
98
+ },
99
+ "gmplsWavebandLabel" : {
100
+ "nodetype" : "namednumber",
101
+ "number" : "6"
102
+ },
103
+ "description" :
104
+ """Determines the interpretation that should be applied to an
105
+ object that encodes a label. The possible types are:
106
+
107
+ gmplsMplsLabel(1) - The label is an MPLS Packet, Cell,
108
+ or Frame Label and is encoded as
109
+ described for the TEXTUAL-
110
+ CONVENTION MplsLabel defined in
111
+ RFC 3811.
112
+
113
+ gmplsPortWavelengthLabel(2) - The label is a Port or Wavelength
114
+ Label as defined in RFC 3471.
115
+
116
+ gmplsFreeformLabel(3) - The label is any form of label
117
+ encoded as an OCTET STRING using
118
+ the TEXTUAL-CONVENTION
119
+ GmplsFreeformLabel.
120
+
121
+ gmplsSonetLabel(4) - The label is a Synchronous Optical
122
+ Network (SONET) Label as
123
+ defined in RFC 4606.
124
+
125
+ gmplsSdhLabel(5) - The label is a Synchronous Digital
126
+ Hierarchy (SDH) Label as defined
127
+ in RFC 4606.
128
+
129
+ gmplsWavebandLabel(6) - The label is a Waveband Label as
130
+ defined in RFC 3471.""",
131
+ "reference" :
132
+ """1. Generalized Multi-Protocol Label Switching (GMPLS) Signaling
133
+ Functional Description, RFC 3471, section 3.
134
+ 2. Definition of Textual Conventions and for Multiprotocol Label
135
+ Switching (MPLS) Management, RFC 3811, section 3.
136
+ 3. Generalized Multi-Protocol Label Switching (GMPLS) Extensions
137
+ for Synchronous Optical Network (SONET) and Synchronous
138
+
139
+
140
+
141
+ Digital Hierarchy (SDH) Control, RFC 4606.""",
142
+ },
143
+ "GmplsSegmentDirectionTC" : {
144
+ "basetype" : "Enumeration",
145
+ "status" : "current",
146
+ "forward" : {
147
+ "nodetype" : "namednumber",
148
+ "number" : "1"
149
+ },
150
+ "reverse" : {
151
+ "nodetype" : "namednumber",
152
+ "number" : "2"
153
+ },
154
+ "description" :
155
+ """The direction of data flow on an Label Switched Path (LSP)
156
+ segment with respect to the head of the LSP.
157
+
158
+ Where an LSP is signaled using a conventional signaling
159
+ protocol, the 'head' of the LSP is the source of the signaling
160
+ (also known as the ingress) and the 'tail' is the destination
161
+ (also known as the egress). For unidirectional LSPs, this
162
+ usually matches the direction of flow of data.
163
+
164
+ For manually configured unidirectional LSPs, the direction of
165
+ the LSP segment matches the direction of flow of data. For
166
+ manually configured bidirectional LSPs, an arbitrary decision
167
+ must be made about which LER is the 'head'.""",
168
+ },
169
+ }, # typedefs
170
+
171
+ "nodes" : {
172
+ "gmplsTCStdMIB" : {
173
+ "nodetype" : "node",
174
+ "moduleName" : "GMPLS-TC-STD-MIB",
175
+ "oid" : "1.3.6.1.2.1.10.166.12",
176
+ "status" : "current",
177
+ }, # node
178
+ }, # nodes
179
+
180
+ }
@@ -0,0 +1,2542 @@
1
+ # python version 1.0 DO NOT EDIT
2
+ #
3
+ # This python file has been generated by smidump version 0.5.0:
4
+ #
5
+ # smidump -f python GMPLS-TE-STD-MIB
6
+
7
+ FILENAME = "./libsmi-0.5.0/mibs/ietf/GMPLS-TE-STD-MIB"
8
+
9
+ MIB = {
10
+ "moduleName" : "GMPLS-TE-STD-MIB",
11
+
12
+ "GMPLS-TE-STD-MIB" : {
13
+ "nodetype" : "module",
14
+ "language" : "SMIv2",
15
+ "organization" :
16
+ """IETF Common Control and Measurement Plane (CCAMP) Working
17
+ Group""",
18
+ "contact" :
19
+ """ Thomas D. Nadeau
20
+ Cisco Systems, Inc.
21
+ Email: tnadeau@cisco.com
22
+ Adrian Farrel
23
+ Old Dog Consulting
24
+ Email: adrian@olddog.co.uk
25
+
26
+ Comments about this document should be emailed directly
27
+ to the CCAMP working group mailing list at
28
+ ccamp@ops.ietf.org.""",
29
+ "description" :
30
+ """Copyright (C) The IETF Trust (2007). This version of
31
+ this MIB module is part of RFC 4802; see the RFC itself for
32
+ full legal notices.
33
+
34
+ This MIB module contains managed object definitions
35
+ for GMPLS Traffic Engineering (TE) as defined in:
36
+ 1. Generalized Multi-Protocol Label Switching (GMPLS)
37
+ Signaling Functional Description, Berger, L. (Editor),
38
+ RFC 3471, January 2003.
39
+ 2. Generalized MPLS Signaling - RSVP-TE Extensions, Berger,
40
+ L. (Editor), RFC 3473, January 2003.""",
41
+ "revisions" : (
42
+ {
43
+ "date" : "2007-02-27 00:00",
44
+ "description" :
45
+ """Initial version issued as part of RFC 4802.""",
46
+ },
47
+ ),
48
+ "identity node" : "gmplsTeStdMIB",
49
+ },
50
+
51
+ "imports" : (
52
+ {"module" : "SNMPv2-SMI", "name" : "MODULE-IDENTITY"},
53
+ {"module" : "SNMPv2-SMI", "name" : "OBJECT-TYPE"},
54
+ {"module" : "SNMPv2-SMI", "name" : "NOTIFICATION-TYPE"},
55
+ {"module" : "SNMPv2-SMI", "name" : "Unsigned32"},
56
+ {"module" : "SNMPv2-SMI", "name" : "Counter32"},
57
+ {"module" : "SNMPv2-SMI", "name" : "Counter64"},
58
+ {"module" : "SNMPv2-SMI", "name" : "zeroDotZero"},
59
+ {"module" : "SNMPv2-SMI", "name" : "Gauge32"},
60
+ {"module" : "SNMPv2-CONF", "name" : "MODULE-COMPLIANCE"},
61
+ {"module" : "SNMPv2-CONF", "name" : "OBJECT-GROUP"},
62
+ {"module" : "SNMPv2-CONF", "name" : "NOTIFICATION-GROUP"},
63
+ {"module" : "SNMPv2-TC", "name" : "TruthValue"},
64
+ {"module" : "SNMPv2-TC", "name" : "TimeStamp"},
65
+ {"module" : "SNMPv2-TC", "name" : "RowPointer"},
66
+ {"module" : "INET-ADDRESS-MIB", "name" : "InetAddress"},
67
+ {"module" : "INET-ADDRESS-MIB", "name" : "InetAddressType"},
68
+ {"module" : "SNMP-FRAMEWORK-MIB", "name" : "SnmpAdminString"},
69
+ {"module" : "MPLS-TE-STD-MIB", "name" : "mplsTunnelIndex"},
70
+ {"module" : "MPLS-TE-STD-MIB", "name" : "mplsTunnelInstance"},
71
+ {"module" : "MPLS-TE-STD-MIB", "name" : "mplsTunnelIngressLSRId"},
72
+ {"module" : "MPLS-TE-STD-MIB", "name" : "mplsTunnelEgressLSRId"},
73
+ {"module" : "MPLS-TE-STD-MIB", "name" : "mplsTunnelHopListIndex"},
74
+ {"module" : "MPLS-TE-STD-MIB", "name" : "mplsTunnelHopPathOptionIndex"},
75
+ {"module" : "MPLS-TE-STD-MIB", "name" : "mplsTunnelHopIndex"},
76
+ {"module" : "MPLS-TE-STD-MIB", "name" : "mplsTunnelARHopListIndex"},
77
+ {"module" : "MPLS-TE-STD-MIB", "name" : "mplsTunnelARHopIndex"},
78
+ {"module" : "MPLS-TE-STD-MIB", "name" : "mplsTunnelCHopListIndex"},
79
+ {"module" : "MPLS-TE-STD-MIB", "name" : "mplsTunnelCHopIndex"},
80
+ {"module" : "MPLS-TE-STD-MIB", "name" : "mplsTunnelEntry"},
81
+ {"module" : "MPLS-TE-STD-MIB", "name" : "mplsTunnelAdminStatus"},
82
+ {"module" : "MPLS-TE-STD-MIB", "name" : "mplsTunnelOperStatus"},
83
+ {"module" : "MPLS-TE-STD-MIB", "name" : "mplsTunnelGroup"},
84
+ {"module" : "MPLS-TE-STD-MIB", "name" : "mplsTunnelScalarGroup"},
85
+ {"module" : "IANA-GMPLS-TC-MIB", "name" : "IANAGmplsLSPEncodingTypeTC"},
86
+ {"module" : "IANA-GMPLS-TC-MIB", "name" : "IANAGmplsSwitchingTypeTC"},
87
+ {"module" : "IANA-GMPLS-TC-MIB", "name" : "IANAGmplsGeneralizedPidTC"},
88
+ {"module" : "IANA-GMPLS-TC-MIB", "name" : "IANAGmplsAdminStatusInformationTC"},
89
+ {"module" : "MPLS-TC-STD-MIB", "name" : "mplsStdMIB"},
90
+ ),
91
+
92
+ "nodes" : {
93
+ "gmplsTeStdMIB" : {
94
+ "nodetype" : "node",
95
+ "moduleName" : "GMPLS-TE-STD-MIB",
96
+ "oid" : "1.3.6.1.2.1.10.166.13",
97
+ "status" : "current",
98
+ }, # node
99
+ "gmplsTeNotifications" : {
100
+ "nodetype" : "node",
101
+ "moduleName" : "GMPLS-TE-STD-MIB",
102
+ "oid" : "1.3.6.1.2.1.10.166.13.0",
103
+ }, # node
104
+ "gmplsTeScalars" : {
105
+ "nodetype" : "node",
106
+ "moduleName" : "GMPLS-TE-STD-MIB",
107
+ "oid" : "1.3.6.1.2.1.10.166.13.1",
108
+ }, # node
109
+ "gmplsTunnelsConfigured" : {
110
+ "nodetype" : "scalar",
111
+ "moduleName" : "GMPLS-TE-STD-MIB",
112
+ "oid" : "1.3.6.1.2.1.10.166.13.1.1",
113
+ "status" : "current",
114
+ "syntax" : {
115
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Gauge32"},
116
+ },
117
+ "access" : "readonly",
118
+ "description" :
119
+ """The number of GMPLS tunnels configured on this device. A GMPLS
120
+
121
+
122
+
123
+ tunnel is considered configured if an entry for the tunnel
124
+ exists in the gmplsTunnelTable and the associated
125
+ mplsTunnelRowStatus is active(1).""",
126
+ }, # scalar
127
+ "gmplsTunnelsActive" : {
128
+ "nodetype" : "scalar",
129
+ "moduleName" : "GMPLS-TE-STD-MIB",
130
+ "oid" : "1.3.6.1.2.1.10.166.13.1.2",
131
+ "status" : "current",
132
+ "syntax" : {
133
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Gauge32"},
134
+ },
135
+ "access" : "readonly",
136
+ "description" :
137
+ """The number of GMPLS tunnels active on this device. A GMPLS
138
+ tunnel is considered active if there is an entry in the
139
+ gmplsTunnelTable and the associated mplsTunnelOperStatus for the
140
+ tunnel is up(1).""",
141
+ }, # scalar
142
+ "gmplsTeObjects" : {
143
+ "nodetype" : "node",
144
+ "moduleName" : "GMPLS-TE-STD-MIB",
145
+ "oid" : "1.3.6.1.2.1.10.166.13.2",
146
+ }, # node
147
+ "gmplsTunnelTable" : {
148
+ "nodetype" : "table",
149
+ "moduleName" : "GMPLS-TE-STD-MIB",
150
+ "oid" : "1.3.6.1.2.1.10.166.13.2.1",
151
+ "status" : "current",
152
+ "description" :
153
+ """The gmplsTunnelTable sparsely extends the mplsTunnelTable of
154
+ MPLS-TE-STD-MIB. It allows GMPLS tunnels to be created between
155
+ an LSR and a remote endpoint, and existing tunnels to be
156
+ reconfigured or removed.
157
+
158
+ Note that only point-to-point tunnel segments are supported,
159
+ although multipoint-to-point and point-to-multipoint
160
+ connections are supported by an LSR acting as a cross-connect.
161
+ Each tunnel can thus have one out-segment originating at this
162
+ LSR and/or one in-segment terminating at this LSR.
163
+
164
+ The row status of an entry in this table is controlled by the
165
+ mplsTunnelRowStatus in the corresponding entry in the
166
+ mplsTunnelTable. When the corresponding mplsTunnelRowStatus has
167
+ value active(1), a row in this table may not be created or
168
+ modified.
169
+
170
+ The exception to this rule is the
171
+ gmplsTunnelAdminStatusInformation object, which can be modified
172
+ while the tunnel is active.""",
173
+ "reference" :
174
+ """1. Multiprotocol Label Switching (MPLS) Traffic Engineering (TE)
175
+ Management Information Base (MIB), RFC 3812.""",
176
+ }, # table
177
+ "gmplsTunnelEntry" : {
178
+ "nodetype" : "row",
179
+ "moduleName" : "GMPLS-TE-STD-MIB",
180
+ "oid" : "1.3.6.1.2.1.10.166.13.2.1.1",
181
+ "create" : "true",
182
+ "status" : "current",
183
+ "linkage" : [
184
+ "mplsTunnelIndex",
185
+ "mplsTunnelInstance",
186
+ "mplsTunnelIngressLSRId",
187
+ "mplsTunnelEgressLSRId",
188
+ ],
189
+ "description" :
190
+ """An entry in this table in association with the corresponding
191
+ entry in the mplsTunnelTable represents a GMPLS tunnel.
192
+
193
+ An entry can be created by a network administrator via SNMP SET
194
+ commands, or in response to signaling protocol events.""",
195
+ }, # row
196
+ "gmplsTunnelUnnumIf" : {
197
+ "nodetype" : "column",
198
+ "moduleName" : "GMPLS-TE-STD-MIB",
199
+ "oid" : "1.3.6.1.2.1.10.166.13.2.1.1.1",
200
+ "status" : "current",
201
+ "syntax" : {
202
+ "type" : { "module" :"SNMPv2-TC", "name" : "TruthValue"},
203
+ },
204
+ "access" : "readwrite",
205
+ "default" : "false",
206
+ "description" :
207
+ """Denotes whether or not this tunnel corresponds to an unnumbered
208
+ interface represented by an entry in the interfaces group table
209
+ (the ifTable) with ifType set to mpls(166).
210
+
211
+
212
+
213
+ This object is only used if mplsTunnelIsIf is set to 'true'.
214
+
215
+ If both this object and the mplsTunnelIsIf object are set to
216
+ 'true', the originating LSR adds an LSP_TUNNEL_INTERFACE_ID
217
+ object to the outgoing Path message.
218
+
219
+ This object contains information that is only used by the
220
+ terminating LSR.""",
221
+ "reference" :
222
+ """1. Signalling Unnumbered Links in RSVP-TE, RFC 3477.""",
223
+ }, # column
224
+ "gmplsTunnelAttributes" : {
225
+ "nodetype" : "column",
226
+ "moduleName" : "GMPLS-TE-STD-MIB",
227
+ "oid" : "1.3.6.1.2.1.10.166.13.2.1.1.2",
228
+ "status" : "current",
229
+ "syntax" : {
230
+ "type" : {
231
+ "basetype" : "Bits",
232
+ "labelRecordingDesired" : {
233
+ "nodetype" : "namednumber",
234
+ "number" : "0"
235
+ },
236
+ },
237
+ },
238
+ "access" : "readwrite",
239
+ "default" : "()",
240
+ "description" :
241
+ """This bitmask indicates optional parameters for this tunnel.
242
+ These bits should be taken in addition to those defined in
243
+ mplsTunnelSessionAttributes in order to determine the full set
244
+ of options to be signaled (for example SESSION_ATTRIBUTES flags
245
+ in RSVP-TE). The following describes these bitfields:
246
+
247
+ labelRecordingDesired
248
+ This flag is set to indicate that label information should be
249
+ included when doing a route record. This bit is not valid
250
+ unless the recordRoute bit is set.""",
251
+ "reference" :
252
+ """1. RSVP-TE: Extensions to RSVP for LSP Tunnels, RFC 3209,
253
+ sections 4.4.3, 4.7.1, and 4.7.2.""",
254
+ }, # column
255
+ "gmplsTunnelLSPEncoding" : {
256
+ "nodetype" : "column",
257
+ "moduleName" : "GMPLS-TE-STD-MIB",
258
+ "oid" : "1.3.6.1.2.1.10.166.13.2.1.1.3",
259
+ "status" : "current",
260
+ "syntax" : {
261
+ "type" : { "module" :"IANA-GMPLS-TC-MIB", "name" : "IANAGmplsLSPEncodingTypeTC"},
262
+ },
263
+ "access" : "readwrite",
264
+ "default" : "tunnelLspNotGmpls",
265
+ "description" :
266
+ """This object indicates the encoding of the LSP being requested.
267
+
268
+ A value of 'tunnelLspNotGmpls' indicates that GMPLS signaling is
269
+ not in use. Some objects in this MIB module may be of use for
270
+ MPLS signaling extensions that do not use GMPLS signaling. By
271
+ setting this object to 'tunnelLspNotGmpls', an application may
272
+
273
+
274
+
275
+
276
+ indicate that only those objects meaningful in MPLS should be
277
+ examined.
278
+
279
+ The values to use are defined in the TEXTUAL-CONVENTION
280
+ IANAGmplsLSPEncodingTypeTC found in the IANA-GMPLS-TC-MIB
281
+ module.""",
282
+ }, # column
283
+ "gmplsTunnelSwitchingType" : {
284
+ "nodetype" : "column",
285
+ "moduleName" : "GMPLS-TE-STD-MIB",
286
+ "oid" : "1.3.6.1.2.1.10.166.13.2.1.1.4",
287
+ "status" : "current",
288
+ "syntax" : {
289
+ "type" : { "module" :"IANA-GMPLS-TC-MIB", "name" : "IANAGmplsSwitchingTypeTC"},
290
+ },
291
+ "access" : "readwrite",
292
+ "default" : "unknown",
293
+ "description" :
294
+ """Indicates the type of switching that should be performed on
295
+ a particular link. This field is needed for links that
296
+ advertise more than one type of switching capability.
297
+
298
+ The values to use are defined in the TEXTUAL-CONVENTION
299
+ IANAGmplsSwitchingTypeTC found in the IANA-GMPLS-TC-MIB module.
300
+
301
+ This object is only meaningful if gmplsTunnelLSPEncodingType
302
+ is not set to 'tunnelLspNotGmpls'.""",
303
+ }, # column
304
+ "gmplsTunnelLinkProtection" : {
305
+ "nodetype" : "column",
306
+ "moduleName" : "GMPLS-TE-STD-MIB",
307
+ "oid" : "1.3.6.1.2.1.10.166.13.2.1.1.5",
308
+ "status" : "current",
309
+ "syntax" : {
310
+ "type" : {
311
+ "basetype" : "Bits",
312
+ "extraTraffic" : {
313
+ "nodetype" : "namednumber",
314
+ "number" : "0"
315
+ },
316
+ "unprotected" : {
317
+ "nodetype" : "namednumber",
318
+ "number" : "1"
319
+ },
320
+ "shared" : {
321
+ "nodetype" : "namednumber",
322
+ "number" : "2"
323
+ },
324
+ "dedicatedOneToOne" : {
325
+ "nodetype" : "namednumber",
326
+ "number" : "3"
327
+ },
328
+ "dedicatedOnePlusOne" : {
329
+ "nodetype" : "namednumber",
330
+ "number" : "4"
331
+ },
332
+ "enhanced" : {
333
+ "nodetype" : "namednumber",
334
+ "number" : "5"
335
+ },
336
+ },
337
+ },
338
+ "access" : "readwrite",
339
+ "default" : "()",
340
+ "description" :
341
+ """This bitmask indicates the level of link protection required. A
342
+ value of zero (no bits set) indicates that any protection may be
343
+ used. The following describes these bitfields:
344
+
345
+ extraTraffic
346
+ This flag is set to indicate that the LSP should use links
347
+ that are protecting other (primary) traffic. Such LSPs may be
348
+ preempted when the links carrying the (primary) traffic being
349
+ protected fail.
350
+
351
+
352
+
353
+
354
+ unprotected
355
+ This flag is set to indicate that the LSP should not use any
356
+ link layer protection.
357
+
358
+ shared
359
+ This flag is set to indicate that a shared link layer
360
+ protection scheme, such as 1:N protection, should be used to
361
+ support the LSP.
362
+
363
+ dedicatedOneToOne
364
+ This flag is set to indicate that a dedicated link layer
365
+ protection scheme, i.e., 1:1 protection, should be used to
366
+ support the LSP.
367
+
368
+ dedicatedOnePlusOne
369
+ This flag is set to indicate that a dedicated link layer
370
+ protection scheme, i.e., 1+1 protection, should be used to
371
+ support the LSP.
372
+
373
+ enhanced
374
+ This flag is set to indicate that a protection scheme that is
375
+ more reliable than Dedicated 1+1 should be used, e.g., 4 fiber
376
+ BLSR/MS-SPRING.
377
+
378
+ This object is only meaningful if gmplsTunnelLSPEncoding is
379
+ not set to 'tunnelLspNotGmpls'.""",
380
+ "reference" :
381
+ """1. Generalized Multi-Protocol Label Switching (GMPLS) Signaling
382
+ Functional Description, RFC 3471, section 7.1.""",
383
+ }, # column
384
+ "gmplsTunnelGPid" : {
385
+ "nodetype" : "column",
386
+ "moduleName" : "GMPLS-TE-STD-MIB",
387
+ "oid" : "1.3.6.1.2.1.10.166.13.2.1.1.6",
388
+ "status" : "current",
389
+ "syntax" : {
390
+ "type" : { "module" :"IANA-GMPLS-TC-MIB", "name" : "IANAGmplsGeneralizedPidTC"},
391
+ },
392
+ "access" : "readwrite",
393
+ "default" : "unknown",
394
+ "description" :
395
+ """This object indicates the payload carried by the LSP. It is only
396
+ required when GMPLS will be used for this LSP.
397
+
398
+ The values to use are defined in the TEXTUAL-CONVENTION
399
+ IANAGmplsGeneralizedPidTC found in the IANA-GMPLS-TC-MIB module.
400
+
401
+ This object is only meaningful if gmplsTunnelLSPEncoding is not
402
+ set to 'tunnelLspNotGmpls'.""",
403
+ }, # column
404
+ "gmplsTunnelSecondary" : {
405
+ "nodetype" : "column",
406
+ "moduleName" : "GMPLS-TE-STD-MIB",
407
+ "oid" : "1.3.6.1.2.1.10.166.13.2.1.1.7",
408
+ "status" : "current",
409
+ "syntax" : {
410
+ "type" : { "module" :"SNMPv2-TC", "name" : "TruthValue"},
411
+ },
412
+ "access" : "readwrite",
413
+ "default" : "false",
414
+ "description" :
415
+ """Indicates that the requested LSP is a secondary LSP.
416
+
417
+ This object is only meaningful if gmplsTunnelLSPEncoding is not
418
+ set to 'tunnelLspNotGmpls'.""",
419
+ "reference" :
420
+ """1. Generalized Multi-Protocol Label Switching (GMPLS) Signaling
421
+ Functional Description, RFC 3471, section 7.1.""",
422
+ }, # column
423
+ "gmplsTunnelDirection" : {
424
+ "nodetype" : "column",
425
+ "moduleName" : "GMPLS-TE-STD-MIB",
426
+ "oid" : "1.3.6.1.2.1.10.166.13.2.1.1.8",
427
+ "status" : "current",
428
+ "syntax" : {
429
+ "type" : {
430
+ "basetype" : "Enumeration",
431
+ "forward" : {
432
+ "nodetype" : "namednumber",
433
+ "number" : "0"
434
+ },
435
+ "bidirectional" : {
436
+ "nodetype" : "namednumber",
437
+ "number" : "1"
438
+ },
439
+ },
440
+ },
441
+ "access" : "readwrite",
442
+ "default" : "forward",
443
+ "description" :
444
+ """Whether this tunnel carries forward data only (is
445
+ unidirectional) or is bidirectional.
446
+
447
+ Values of this object other than 'forward' are meaningful
448
+ only if gmplsTunnelLSPEncoding is not set to
449
+ 'tunnelLspNotGmpls'.""",
450
+ }, # column
451
+ "gmplsTunnelPathComp" : {
452
+ "nodetype" : "column",
453
+ "moduleName" : "GMPLS-TE-STD-MIB",
454
+ "oid" : "1.3.6.1.2.1.10.166.13.2.1.1.9",
455
+ "status" : "current",
456
+ "syntax" : {
457
+ "type" : {
458
+ "basetype" : "Enumeration",
459
+ "dynamicFull" : {
460
+ "nodetype" : "namednumber",
461
+ "number" : "1"
462
+ },
463
+ "explicit" : {
464
+ "nodetype" : "namednumber",
465
+ "number" : "2"
466
+ },
467
+ "dynamicPartial" : {
468
+ "nodetype" : "namednumber",
469
+ "number" : "3"
470
+ },
471
+ },
472
+ },
473
+ "access" : "readwrite",
474
+ "default" : "dynamicFull",
475
+ "description" :
476
+ """This value instructs the source node on how to perform path
477
+ computation on the explicit route specified by the associated
478
+ entries in the gmplsTunnelHopTable.
479
+
480
+ dynamicFull
481
+ The user specifies at least the source and
482
+ destination of the path and expects that the Constrained
483
+
484
+
485
+
486
+ Shortest Path First (CSPF) will calculate the remainder
487
+ of the path.
488
+
489
+ explicit
490
+ The user specifies the entire path for the tunnel to
491
+ take. This path may contain strict or loose hops.
492
+ Evaluation of the explicit route will be performed
493
+ hop by hop through the network.
494
+
495
+ dynamicPartial
496
+ The user specifies at least the source and
497
+ destination of the path and expects that the CSPF
498
+ will calculate the remainder of the path. The path
499
+ computed by CSPF is allowed to be only partially
500
+ computed allowing the remainder of the path to be
501
+ filled in across the network.
502
+
503
+ When an entry is present in the gmplsTunnelTable for a
504
+ tunnel, gmplsTunnelPathComp MUST be used and any
505
+ corresponding mplsTunnelHopEntryPathComp object in the
506
+ mplsTunnelHopTable MUST be ignored and SHOULD not be set.
507
+
508
+ mplsTunnelHopTable and mplsTunnelHopEntryPathComp are part of
509
+ MPLS-TE-STD-MIB.
510
+
511
+ This object should be ignored if the value of
512
+ gmplsTunnelLSPEncoding is 'tunnelLspNotGmpls'.""",
513
+ "reference" :
514
+ """1. Multiprotocol Label Switching (MPLS) Traffic Engineering (TE)
515
+ Management Information Base (MIB), RFC 3812.""",
516
+ }, # column
517
+ "gmplsTunnelUpstreamNotifyRecipientType" : {
518
+ "nodetype" : "column",
519
+ "moduleName" : "GMPLS-TE-STD-MIB",
520
+ "oid" : "1.3.6.1.2.1.10.166.13.2.1.1.10",
521
+ "status" : "current",
522
+ "syntax" : {
523
+ "type" : { "module" :"INET-ADDRESS-MIB", "name" : "InetAddressType"},
524
+ },
525
+ "access" : "readwrite",
526
+ "default" : "unknown",
527
+ "description" :
528
+ """This object is used to aid in interpretation of
529
+ gmplsTunnelUpstreamNotifyRecipient.""",
530
+ }, # column
531
+ "gmplsTunnelUpstreamNotifyRecipient" : {
532
+ "nodetype" : "column",
533
+ "moduleName" : "GMPLS-TE-STD-MIB",
534
+ "oid" : "1.3.6.1.2.1.10.166.13.2.1.1.11",
535
+ "status" : "current",
536
+ "syntax" : {
537
+ "type" : { "module" :"INET-ADDRESS-MIB", "name" : "InetAddress"},
538
+ },
539
+ "access" : "readwrite",
540
+ "default" : "0x00000000",
541
+ "description" :
542
+ """Indicates the address of the upstream recipient for Notify
543
+ messages relating to this tunnel and issued by this LSR. This
544
+ information is typically received from an upstream LSR in a Path
545
+ message.
546
+
547
+ This object is only valid when signaling a tunnel using RSVP.
548
+
549
+ It is also not valid at the head end of a tunnel since there are
550
+ no upstream LSRs to which to send a Notify message.
551
+
552
+ This object is interpreted in the context of the value of
553
+ gmplsTunnelUpstreamNotifyRecipientType. If this object is set to
554
+ 0, the value of gmplsTunnelUpstreamNotifyRecipientType MUST be
555
+ set to unknown(0).""",
556
+ "reference" :
557
+ """1. Generalized MPLS Signaling - RSVP-TE Extensions, RFC 3473,
558
+ section 4.2. """,
559
+ }, # column
560
+ "gmplsTunnelSendResvNotifyRecipientType" : {
561
+ "nodetype" : "column",
562
+ "moduleName" : "GMPLS-TE-STD-MIB",
563
+ "oid" : "1.3.6.1.2.1.10.166.13.2.1.1.12",
564
+ "status" : "current",
565
+ "syntax" : {
566
+ "type" : { "module" :"INET-ADDRESS-MIB", "name" : "InetAddressType"},
567
+ },
568
+ "access" : "readwrite",
569
+ "default" : "unknown",
570
+ "description" :
571
+ """This object is used to aid in interpretation of
572
+ gmplsTunnelSendResvNotifyRecipient.""",
573
+ }, # column
574
+ "gmplsTunnelSendResvNotifyRecipient" : {
575
+ "nodetype" : "column",
576
+ "moduleName" : "GMPLS-TE-STD-MIB",
577
+ "oid" : "1.3.6.1.2.1.10.166.13.2.1.1.13",
578
+ "status" : "current",
579
+ "syntax" : {
580
+ "type" : { "module" :"INET-ADDRESS-MIB", "name" : "InetAddress"},
581
+ },
582
+ "access" : "readwrite",
583
+ "default" : "0x00000000",
584
+ "description" :
585
+ """Indicates to an upstream LSR the address to which it should send
586
+ downstream Notify messages relating to this tunnel.
587
+
588
+ This object is only valid when signaling a tunnel using RSVP.
589
+
590
+ It is also not valid at the head end of the tunnel since no Resv
591
+ messages are sent from that LSR for this tunnel.
592
+
593
+ If set to 0, no Notify Request object will be included in the
594
+ outgoing Resv messages.
595
+
596
+ This object is interpreted in the context of the value of
597
+ gmplsTunnelSendResvNotifyRecipientType. If this object is set to
598
+
599
+
600
+
601
+ 0, the value of gmplsTunnelSendResvNotifyRecipientType MUST be
602
+ set to unknown(0).""",
603
+ "reference" :
604
+ """1. Generalized MPLS Signaling - RSVP-TE Extensions, RFC 3473,
605
+ section 4.2. """,
606
+ }, # column
607
+ "gmplsTunnelDownstreamNotifyRecipientType" : {
608
+ "nodetype" : "column",
609
+ "moduleName" : "GMPLS-TE-STD-MIB",
610
+ "oid" : "1.3.6.1.2.1.10.166.13.2.1.1.14",
611
+ "status" : "current",
612
+ "syntax" : {
613
+ "type" : { "module" :"INET-ADDRESS-MIB", "name" : "InetAddressType"},
614
+ },
615
+ "access" : "readwrite",
616
+ "default" : "unknown",
617
+ "description" :
618
+ """This object is used to aid in interpretation of
619
+ gmplsTunnelDownstreamNotifyRecipient.""",
620
+ }, # column
621
+ "gmplsTunnelDownstreamNotifyRecipient" : {
622
+ "nodetype" : "column",
623
+ "moduleName" : "GMPLS-TE-STD-MIB",
624
+ "oid" : "1.3.6.1.2.1.10.166.13.2.1.1.15",
625
+ "status" : "current",
626
+ "syntax" : {
627
+ "type" : { "module" :"INET-ADDRESS-MIB", "name" : "InetAddress"},
628
+ },
629
+ "access" : "readwrite",
630
+ "default" : "0x00000000",
631
+ "description" :
632
+ """Indicates the address of the downstream recipient for Notify
633
+ messages relating to this tunnel and issued by this LSR. This
634
+ information is typically received from an upstream LSR in a Resv
635
+ message. This object is only valid when signaling a tunnel using
636
+ RSVP.
637
+
638
+ It is also not valid at the tail end of a tunnel since there are
639
+ no downstream LSRs to which to send a Notify message.
640
+
641
+ This object is interpreted in the context of the value of
642
+ gmplsTunnelDownstreamNotifyRecipientType. If this object is set
643
+ to 0, the value of gmplsTunnelDownstreamNotifyRecipientType MUST
644
+ be set to unknown(0).""",
645
+ "reference" :
646
+ """1. Generalized MPLS Signaling - RSVP-TE Extensions, RFC 3473,
647
+ section 4.2.""",
648
+ }, # column
649
+ "gmplsTunnelSendPathNotifyRecipientType" : {
650
+ "nodetype" : "column",
651
+ "moduleName" : "GMPLS-TE-STD-MIB",
652
+ "oid" : "1.3.6.1.2.1.10.166.13.2.1.1.16",
653
+ "status" : "current",
654
+ "syntax" : {
655
+ "type" : { "module" :"INET-ADDRESS-MIB", "name" : "InetAddressType"},
656
+ },
657
+ "access" : "readwrite",
658
+ "default" : "unknown",
659
+ "description" :
660
+ """This object is used to aid in interpretation of
661
+ gmplsTunnelSendPathNotifyRecipient.""",
662
+ }, # column
663
+ "gmplsTunnelSendPathNotifyRecipient" : {
664
+ "nodetype" : "column",
665
+ "moduleName" : "GMPLS-TE-STD-MIB",
666
+ "oid" : "1.3.6.1.2.1.10.166.13.2.1.1.17",
667
+ "status" : "current",
668
+ "syntax" : {
669
+ "type" : { "module" :"INET-ADDRESS-MIB", "name" : "InetAddress"},
670
+ },
671
+ "access" : "readwrite",
672
+ "default" : "0x00000000",
673
+ "description" :
674
+ """Indicates to a downstream LSR the address to which it should
675
+ send upstream Notify messages relating to this tunnel.
676
+
677
+ This object is only valid when signaling a tunnel using RSVP.
678
+
679
+ It is also not valid at the tail end of the tunnel since no Path
680
+ messages are sent from that LSR for this tunnel.
681
+
682
+ If set to 0, no Notify Request object will be included in the
683
+ outgoing Path messages.
684
+
685
+ This object is interpreted in the context of the value of
686
+ gmplsTunnelSendPathNotifyRecipientType. If this object is set to
687
+ 0, the value of gmplsTunnelSendPathNotifyRecipientType MUST be
688
+ set to unknown(0).""",
689
+ "reference" :
690
+ """1. Generalized MPLS Signaling - RSVP-TE Extensions, RFC 3473,
691
+ section 4.2. """,
692
+ }, # column
693
+ "gmplsTunnelAdminStatusFlags" : {
694
+ "nodetype" : "column",
695
+ "moduleName" : "GMPLS-TE-STD-MIB",
696
+ "oid" : "1.3.6.1.2.1.10.166.13.2.1.1.18",
697
+ "status" : "current",
698
+ "syntax" : {
699
+ "type" : { "module" :"IANA-GMPLS-TC-MIB", "name" : "IANAGmplsAdminStatusInformationTC"},
700
+ },
701
+ "access" : "readwrite",
702
+ "default" : "()",
703
+ "description" :
704
+ """Determines the setting of the Admin Status flags in the
705
+ Admin Status object or TLV, as described in RFC 3471. Setting
706
+ this field to a non-zero value will result in the inclusion of
707
+ the Admin Status object on signaling messages.
708
+
709
+ The values to use are defined in the TEXTUAL-CONVENTION
710
+ IANAGmplsAdminStatusInformationTC found in the
711
+ IANA-GMPLS-TC-MIB module.
712
+
713
+ This value of this object can be modified when the
714
+ corresponding mplsTunnelRowStatus and mplsTunnelAdminStatus
715
+ is active(1). By doing so, a new signaling message will be
716
+
717
+
718
+
719
+ triggered including the requested Admin Status object or
720
+ TLV.""",
721
+ "reference" :
722
+ """1. Generalized Multi-Protocol Label Switching (GMPLS) Signaling
723
+ Functional Description, RFC 3471, section 8.""",
724
+ }, # column
725
+ "gmplsTunnelExtraParamsPtr" : {
726
+ "nodetype" : "column",
727
+ "moduleName" : "GMPLS-TE-STD-MIB",
728
+ "oid" : "1.3.6.1.2.1.10.166.13.2.1.1.19",
729
+ "status" : "current",
730
+ "syntax" : {
731
+ "type" : { "module" :"SNMPv2-TC", "name" : "RowPointer"},
732
+ },
733
+ "access" : "readwrite",
734
+ "default" : "0.0",
735
+ "description" :
736
+ """Some tunnels will run over transports that can usefully support
737
+ technology-specific additional parameters (for example,
738
+ Synchronous Optical Network (SONET) resource usage). Such
739
+ parameters can be supplied in an external table and referenced
740
+ from here.
741
+
742
+ A value of zeroDotzero in this attribute indicates that there
743
+ is no such additional information.""",
744
+ }, # column
745
+ "gmplsTunnelHopTable" : {
746
+ "nodetype" : "table",
747
+ "moduleName" : "GMPLS-TE-STD-MIB",
748
+ "oid" : "1.3.6.1.2.1.10.166.13.2.2",
749
+ "status" : "current",
750
+ "description" :
751
+ """The gmplsTunnelHopTable sparsely extends the mplsTunnelHopTable
752
+ of MPLS-TE-STD-MIB. It is used to indicate the Explicit Labels
753
+ to be used in an explicit path for a GMPLS tunnel defined in the
754
+ mplsTunnelTable and gmplsTunnelTable, when it is established
755
+ using signaling. It does not insert new hops, but does define
756
+ new values for hops defined in the mplsTunnelHopTable.
757
+
758
+ Each row in this table is indexed by the same indexes as in the
759
+ mplsTunnelHopTable. It is acceptable for some rows in the
760
+ mplsTunnelHopTable to have corresponding entries in this table
761
+ and some to have no corresponding entry in this table.
762
+
763
+ The storage type for this entry is given by the value
764
+ of mplsTunnelHopStorageType in the corresponding entry in the
765
+ mplsTunnelHopTable.
766
+
767
+ The row status of an entry in this table is controlled by
768
+ mplsTunnelHopRowStatus in the corresponding entry in the
769
+ mplsTunnelHopTable. That is, it is not permitted to create a row
770
+
771
+
772
+
773
+ in this table, or to modify an existing row, when the
774
+ corresponding mplsTunnelHopRowStatus has the value active(1).""",
775
+ "reference" :
776
+ """1. Multiprotocol Label Switching (MPLS) Traffic Engineering (TE)
777
+ Management Information Base (MIB), RFC 3812.
778
+ 2. Generalized MPLS Signaling - RSVP-TE Extensions, RFC 3473.""",
779
+ }, # table
780
+ "gmplsTunnelHopEntry" : {
781
+ "nodetype" : "row",
782
+ "moduleName" : "GMPLS-TE-STD-MIB",
783
+ "oid" : "1.3.6.1.2.1.10.166.13.2.2.1",
784
+ "create" : "true",
785
+ "status" : "current",
786
+ "linkage" : [
787
+ "mplsTunnelHopListIndex",
788
+ "mplsTunnelHopPathOptionIndex",
789
+ "mplsTunnelHopIndex",
790
+ ],
791
+ "description" :
792
+ """An entry in this table represents additions to a tunnel hop
793
+ defined in mplsTunnelHopEntry. At an ingress to a tunnel, an
794
+ entry in this table is created by a network administrator for an
795
+ ERLSP to be set up by a signaling protocol. At transit and
796
+ egress nodes, an entry in this table may be used to represent the
797
+ explicit path instructions received using the signaling
798
+ protocol.""",
799
+ }, # row
800
+ "gmplsTunnelHopLabelStatuses" : {
801
+ "nodetype" : "column",
802
+ "moduleName" : "GMPLS-TE-STD-MIB",
803
+ "oid" : "1.3.6.1.2.1.10.166.13.2.2.1.1",
804
+ "status" : "current",
805
+ "syntax" : {
806
+ "type" : {
807
+ "basetype" : "Bits",
808
+ "forwardPresent" : {
809
+ "nodetype" : "namednumber",
810
+ "number" : "0"
811
+ },
812
+ "reversePresent" : {
813
+ "nodetype" : "namednumber",
814
+ "number" : "1"
815
+ },
816
+ },
817
+ },
818
+ "access" : "readonly",
819
+ "default" : "()",
820
+ "description" :
821
+ """This bitmask indicates the presence of labels indicated by the
822
+ gmplsTunnelHopExplicitForwardLabel or
823
+ gmplsTunnelHopExplicitForwardLabelPtr, and
824
+ gmplsTunnelHopExplicitReverseLabel or
825
+
826
+
827
+
828
+ gmplsTunnelHopExplicitReverseLabelPtr objects.
829
+
830
+ For the Present bits, a set bit indicates that a label is
831
+ present for this hop in the route. This allows zero to be a
832
+ valid label value.""",
833
+ }, # column
834
+ "gmplsTunnelHopExplicitForwardLabel" : {
835
+ "nodetype" : "column",
836
+ "moduleName" : "GMPLS-TE-STD-MIB",
837
+ "oid" : "1.3.6.1.2.1.10.166.13.2.2.1.2",
838
+ "status" : "current",
839
+ "syntax" : {
840
+ "type" : { "module" :"", "name" : "Unsigned32"},
841
+ },
842
+ "access" : "readwrite",
843
+ "description" :
844
+ """If gmplsTunnelHopLabelStatuses object indicates that a Forward
845
+ Label is present and gmplsTunnelHopExplicitForwardLabelPtr
846
+ contains the value zeroDotZero, then the label to use on this
847
+ hop is represented by the value of this object.""",
848
+ }, # column
849
+ "gmplsTunnelHopExplicitForwardLabelPtr" : {
850
+ "nodetype" : "column",
851
+ "moduleName" : "GMPLS-TE-STD-MIB",
852
+ "oid" : "1.3.6.1.2.1.10.166.13.2.2.1.3",
853
+ "status" : "current",
854
+ "syntax" : {
855
+ "type" : { "module" :"SNMPv2-TC", "name" : "RowPointer"},
856
+ },
857
+ "access" : "readwrite",
858
+ "default" : "0.0",
859
+ "description" :
860
+ """If the gmplsTunnelHopLabelStatuses object indicates that a
861
+ Forward Label is present, this object contains a pointer to a
862
+ row in another MIB table (such as the gmplsLabelTable of
863
+ GMPLS-LABEL-STD-MIB) that contains the label to use on this hop
864
+ in the forward direction.
865
+
866
+ If the gmplsTunnelHopLabelStatuses object indicates that a
867
+ Forward Label is present and this object contains the value
868
+ zeroDotZero, then the label to use on this hop is found in the
869
+ gmplsTunnelHopExplicitForwardLabel object.""",
870
+ }, # column
871
+ "gmplsTunnelHopExplicitReverseLabel" : {
872
+ "nodetype" : "column",
873
+ "moduleName" : "GMPLS-TE-STD-MIB",
874
+ "oid" : "1.3.6.1.2.1.10.166.13.2.2.1.4",
875
+ "status" : "current",
876
+ "syntax" : {
877
+ "type" : { "module" :"", "name" : "Unsigned32"},
878
+ },
879
+ "access" : "readwrite",
880
+ "description" :
881
+ """If the gmplsTunnelHopLabelStatuses object indicates that a
882
+ Reverse Label is present and
883
+ gmplsTunnelHopExplicitReverseLabelPtr contains the value
884
+ zeroDotZero, then the label to use on this hop is found in
885
+ this object encoded as a 32-bit integer.""",
886
+ }, # column
887
+ "gmplsTunnelHopExplicitReverseLabelPtr" : {
888
+ "nodetype" : "column",
889
+ "moduleName" : "GMPLS-TE-STD-MIB",
890
+ "oid" : "1.3.6.1.2.1.10.166.13.2.2.1.5",
891
+ "status" : "current",
892
+ "syntax" : {
893
+ "type" : { "module" :"SNMPv2-TC", "name" : "RowPointer"},
894
+ },
895
+ "access" : "readwrite",
896
+ "default" : "0.0",
897
+ "description" :
898
+ """If the gmplsTunnelHopLabelStatuses object indicates that a
899
+ Reverse Label is present, this object contains a pointer to a
900
+ row in another MIB table (such as the gmplsLabelTable of
901
+ GMPLS-LABEL-STD-MIB) that contains the label to use on this hop
902
+ in the reverse direction.
903
+
904
+ If the gmplsTunnelHopLabelStatuses object indicates that a
905
+ Reverse Label is present and this object contains the value
906
+ zeroDotZero, then the label to use on this hop is found in the
907
+ gmplsTunnelHopExplicitReverseLabel object.""",
908
+ }, # column
909
+ "gmplsTunnelARHopTable" : {
910
+ "nodetype" : "table",
911
+ "moduleName" : "GMPLS-TE-STD-MIB",
912
+ "oid" : "1.3.6.1.2.1.10.166.13.2.3",
913
+ "status" : "current",
914
+ "description" :
915
+ """The gmplsTunnelARHopTable sparsely extends the
916
+ mplsTunnelARHopTable of MPLS-TE-STD-MIB. It is used to
917
+ indicate the labels currently in use for a GMPLS tunnel
918
+ defined in the mplsTunnelTable and gmplsTunnelTable, as
919
+ reported by the signaling protocol. It does not insert
920
+ new hops, but does define new values for hops defined in
921
+ the mplsTunnelARHopTable.
922
+
923
+ Each row in this table is indexed by the same indexes as in the
924
+ mplsTunnelARHopTable. It is acceptable for some rows in the
925
+ mplsTunnelARHopTable to have corresponding entries in this table
926
+ and some to have no corresponding entry in this table.
927
+
928
+ Note that since the information necessary to build entries
929
+ within this table is not provided by some signaling protocols
930
+ and might not be returned in all cases of other signaling
931
+ protocols, implementation of this table and the
932
+ mplsTunnelARHopTable is optional. Furthermore, since the
933
+ information in this table is actually provided by the
934
+ signaling protocol after the path has been set up, the entries
935
+ in this table are provided only for observation, and hence,
936
+ all variables in this table are accessible exclusively as
937
+ read-only.""",
938
+ "reference" :
939
+ """1. Extensions to RSVP for LSP Tunnels, RFC 3209.
940
+
941
+
942
+
943
+ 2. Generalized MPLS Signaling - RSVP-TE Extensions, RFC 3473.
944
+ 3. Multiprotocol Label Switching (MPLS) Traffic Engineering (TE)
945
+ Management Information Base (MIB), RFC 3812.""",
946
+ }, # table
947
+ "gmplsTunnelARHopEntry" : {
948
+ "nodetype" : "row",
949
+ "moduleName" : "GMPLS-TE-STD-MIB",
950
+ "oid" : "1.3.6.1.2.1.10.166.13.2.3.1",
951
+ "status" : "current",
952
+ "linkage" : [
953
+ "mplsTunnelARHopListIndex",
954
+ "mplsTunnelARHopIndex",
955
+ ],
956
+ "description" :
957
+ """An entry in this table represents additions to a tunnel hop
958
+ visible in mplsTunnelARHopEntry. An entry is created by the
959
+ signaling protocol for a signaled ERLSP set up by the signaling
960
+ protocol.
961
+
962
+ At any node on the LSP (ingress, transit, or egress), this table
963
+ and the mplsTunnelARHopTable (if the tables are supported and if
964
+ the signaling protocol is recording actual route information)
965
+ contain the actual route of the whole tunnel. If the signaling
966
+ protocol is not recording the actual route, this table MAY
967
+ report the information from the gmplsTunnelHopTable or the
968
+ gmplsTunnelCHopTable.
969
+
970
+ Note that the recording of actual labels is distinct from the
971
+ recording of the actual route in some signaling protocols. This
972
+ feature is enabled using the gmplsTunnelAttributes object.""",
973
+ }, # row
974
+ "gmplsTunnelARHopLabelStatuses" : {
975
+ "nodetype" : "column",
976
+ "moduleName" : "GMPLS-TE-STD-MIB",
977
+ "oid" : "1.3.6.1.2.1.10.166.13.2.3.1.1",
978
+ "status" : "current",
979
+ "syntax" : {
980
+ "type" : {
981
+ "basetype" : "Bits",
982
+ "forwardPresent" : {
983
+ "nodetype" : "namednumber",
984
+ "number" : "0"
985
+ },
986
+ "reversePresent" : {
987
+ "nodetype" : "namednumber",
988
+ "number" : "1"
989
+ },
990
+ "forwardGlobal" : {
991
+ "nodetype" : "namednumber",
992
+ "number" : "2"
993
+ },
994
+ "reverseGlobal" : {
995
+ "nodetype" : "namednumber",
996
+ "number" : "3"
997
+ },
998
+ },
999
+ },
1000
+ "access" : "readonly",
1001
+ "description" :
1002
+ """This bitmask indicates the presence and status of labels
1003
+ indicated by the gmplsTunnelARHopExplicitForwardLabel or
1004
+ gmplsTunnelARHopExplicitForwardLabelPtr, and
1005
+ gmplsTunnelARHopExplicitReverseLabel or
1006
+ gmplsTunnelARHopExplicitReverseLabelPtr objects.
1007
+
1008
+ For the Present bits, a set bit indicates that a label is
1009
+ present for this hop in the route.
1010
+
1011
+ For the Global bits, a set bit indicates that the label comes
1012
+ from the Global Label Space; a clear bit indicates that this is
1013
+ a Per-Interface label. A Global bit only has meaning if the
1014
+ corresponding Present bit is set.""",
1015
+ }, # column
1016
+ "gmplsTunnelARHopExplicitForwardLabel" : {
1017
+ "nodetype" : "column",
1018
+ "moduleName" : "GMPLS-TE-STD-MIB",
1019
+ "oid" : "1.3.6.1.2.1.10.166.13.2.3.1.2",
1020
+ "status" : "current",
1021
+ "syntax" : {
1022
+ "type" : { "module" :"", "name" : "Unsigned32"},
1023
+ },
1024
+ "access" : "readonly",
1025
+ "description" :
1026
+ """If the gmplsTunnelARHopLabelStatuses object indicates that a
1027
+ Forward Label is present and
1028
+ gmplsTunnelARHopExplicitForwardLabelPtr contains the value
1029
+ zeroDotZero, then the label in use on this hop is found in this
1030
+ object encoded as a 32-bit integer.""",
1031
+ }, # column
1032
+ "gmplsTunnelARHopExplicitForwardLabelPtr" : {
1033
+ "nodetype" : "column",
1034
+ "moduleName" : "GMPLS-TE-STD-MIB",
1035
+ "oid" : "1.3.6.1.2.1.10.166.13.2.3.1.3",
1036
+ "status" : "current",
1037
+ "syntax" : {
1038
+ "type" : { "module" :"SNMPv2-TC", "name" : "RowPointer"},
1039
+ },
1040
+ "access" : "readonly",
1041
+ "description" :
1042
+ """If the gmplsTunnelARHopLabelStatuses object indicates that a
1043
+ Forward Label is present, this object contains a pointer to a
1044
+ row in another MIB table (such as the gmplsLabelTable of
1045
+ GMPLS-LABEL-STD-MIB) that contains the label in use on this hop
1046
+ in the forward direction.
1047
+
1048
+ If the gmplsTunnelARHopLabelStatuses object indicates that a
1049
+ Forward Label is present and this object contains the value
1050
+ zeroDotZero, then the label in use on this hop is found in the
1051
+ gmplsTunnelARHopExplicitForwardLabel object.""",
1052
+ }, # column
1053
+ "gmplsTunnelARHopExplicitReverseLabel" : {
1054
+ "nodetype" : "column",
1055
+ "moduleName" : "GMPLS-TE-STD-MIB",
1056
+ "oid" : "1.3.6.1.2.1.10.166.13.2.3.1.4",
1057
+ "status" : "current",
1058
+ "syntax" : {
1059
+ "type" : { "module" :"", "name" : "Unsigned32"},
1060
+ },
1061
+ "access" : "readonly",
1062
+ "description" :
1063
+ """If the gmplsTunnelARHopLabelStatuses object indicates that a
1064
+ Reverse Label is present and
1065
+ gmplsTunnelARHopExplicitReverseLabelPtr contains the value
1066
+ zeroDotZero, then the label in use on this hop is found in this
1067
+ object encoded as a 32-bit integer.""",
1068
+ }, # column
1069
+ "gmplsTunnelARHopExplicitReverseLabelPtr" : {
1070
+ "nodetype" : "column",
1071
+ "moduleName" : "GMPLS-TE-STD-MIB",
1072
+ "oid" : "1.3.6.1.2.1.10.166.13.2.3.1.5",
1073
+ "status" : "current",
1074
+ "syntax" : {
1075
+ "type" : { "module" :"SNMPv2-TC", "name" : "RowPointer"},
1076
+ },
1077
+ "access" : "readonly",
1078
+ "description" :
1079
+ """If the gmplsTunnelARHopLabelStatuses object indicates that a
1080
+ Reverse Label is present, this object contains a pointer to a
1081
+ row in another MIB table (such as the gmplsLabelTable of
1082
+ GMPLS-LABEL-STD-MIB) that contains the label in use on this hop
1083
+ in the reverse direction.
1084
+
1085
+ If the gmplsTunnelARHopLabelStatuses object indicates that a
1086
+ Reverse Label is present and this object contains the value
1087
+ zeroDotZero, then the label in use on this hop is found in the
1088
+ gmplsTunnelARHopExplicitReverseLabel object.""",
1089
+ }, # column
1090
+ "gmplsTunnelARHopProtection" : {
1091
+ "nodetype" : "column",
1092
+ "moduleName" : "GMPLS-TE-STD-MIB",
1093
+ "oid" : "1.3.6.1.2.1.10.166.13.2.3.1.6",
1094
+ "status" : "current",
1095
+ "syntax" : {
1096
+ "type" : {
1097
+ "basetype" : "Bits",
1098
+ "localAvailable" : {
1099
+ "nodetype" : "namednumber",
1100
+ "number" : "0"
1101
+ },
1102
+ "localInUse" : {
1103
+ "nodetype" : "namednumber",
1104
+ "number" : "1"
1105
+ },
1106
+ },
1107
+ },
1108
+ "access" : "readonly",
1109
+ "description" :
1110
+ """Availability and usage of protection on the reported link.
1111
+
1112
+ localAvailable
1113
+ This flag is set to indicate that the link downstream of this
1114
+ node is protected via a local repair mechanism.
1115
+
1116
+ localInUse
1117
+ This flag is set to indicate that a local repair mechanism is
1118
+ in use to maintain this tunnel (usually in the face of an
1119
+ outage of the link it was previously routed over).""",
1120
+ "reference" :
1121
+ """1. RSVP-TE: Extensions to RSVP for LSP Tunnels, RFC 3209,
1122
+ section 4.4.1.""",
1123
+ }, # column
1124
+ "gmplsTunnelCHopTable" : {
1125
+ "nodetype" : "table",
1126
+ "moduleName" : "GMPLS-TE-STD-MIB",
1127
+ "oid" : "1.3.6.1.2.1.10.166.13.2.4",
1128
+ "status" : "current",
1129
+ "description" :
1130
+ """The gmplsTunnelCHopTable sparsely extends the
1131
+ mplsTunnelCHopTable of MPLS-TE-STD-MIB. It is used to indicate
1132
+ additional information about the hops of a GMPLS tunnel defined
1133
+ in the mplsTunnelTable and gmplsTunnelTable, as computed by a
1134
+ constraint-based routing protocol, based on the
1135
+ mplsTunnelHopTable and the gmplsTunnelHopTable.
1136
+
1137
+ Each row in this table is indexed by the same indexes as in the
1138
+ mplsTunnelCHopTable. It is acceptable for some rows in the
1139
+ mplsTunnelCHopTable to have corresponding entries in this table
1140
+ and some to have no corresponding entry in this table.
1141
+
1142
+ Please note that since the information necessary to build
1143
+ entries within this table may not be supported by some LSRs,
1144
+ implementation of this table is optional.
1145
+
1146
+ Furthermore, since the information in this table is actually
1147
+ provided by a path computation component after the path has been
1148
+ computed, the entries in this table are provided only for
1149
+ observation, and hence, all objects in this table are accessible
1150
+ exclusively as read-only.""",
1151
+ "reference" :
1152
+ """1. Multiprotocol Label Switching (MPLS) Traffic Engineering (TE)
1153
+ Management Information Base (MIB), RFC 3812.
1154
+ 2. Generalized MPLS Signaling - RSVP-TE Extensions, RFC 3473.""",
1155
+ }, # table
1156
+ "gmplsTunnelCHopEntry" : {
1157
+ "nodetype" : "row",
1158
+ "moduleName" : "GMPLS-TE-STD-MIB",
1159
+ "oid" : "1.3.6.1.2.1.10.166.13.2.4.1",
1160
+ "status" : "current",
1161
+ "linkage" : [
1162
+ "mplsTunnelCHopListIndex",
1163
+ "mplsTunnelCHopIndex",
1164
+ ],
1165
+ "description" :
1166
+ """An entry in this table represents additions to a computed tunnel
1167
+ hop visible in mplsTunnelCHopEntry. An entry is created by a
1168
+ path computation component based on the hops specified in the
1169
+ corresponding mplsTunnelHopTable and gmplsTunnelHopTable.
1170
+
1171
+ At a transit LSR, this table (if the table is supported) MAY
1172
+ contain the path computed by a path computation engine on (or on
1173
+
1174
+
1175
+
1176
+ behalf of) the transit LSR.""",
1177
+ }, # row
1178
+ "gmplsTunnelCHopLabelStatuses" : {
1179
+ "nodetype" : "column",
1180
+ "moduleName" : "GMPLS-TE-STD-MIB",
1181
+ "oid" : "1.3.6.1.2.1.10.166.13.2.4.1.1",
1182
+ "status" : "current",
1183
+ "syntax" : {
1184
+ "type" : {
1185
+ "basetype" : "Bits",
1186
+ "forwardPresent" : {
1187
+ "nodetype" : "namednumber",
1188
+ "number" : "0"
1189
+ },
1190
+ "reversePresent" : {
1191
+ "nodetype" : "namednumber",
1192
+ "number" : "1"
1193
+ },
1194
+ },
1195
+ },
1196
+ "access" : "readonly",
1197
+ "description" :
1198
+ """This bitmask indicates the presence of labels indicated by the
1199
+ gmplsTunnelCHopExplicitForwardLabel or
1200
+ gmplsTunnelCHopExplicitForwardLabelPtr and
1201
+ gmplsTunnelCHopExplicitReverseLabel or
1202
+ gmplsTunnelCHopExplicitReverseLabelPtr objects.
1203
+
1204
+ A set bit indicates that a label is present for this hop in the
1205
+ route, thus allowing zero to be a valid label value.""",
1206
+ }, # column
1207
+ "gmplsTunnelCHopExplicitForwardLabel" : {
1208
+ "nodetype" : "column",
1209
+ "moduleName" : "GMPLS-TE-STD-MIB",
1210
+ "oid" : "1.3.6.1.2.1.10.166.13.2.4.1.2",
1211
+ "status" : "current",
1212
+ "syntax" : {
1213
+ "type" : { "module" :"", "name" : "Unsigned32"},
1214
+ },
1215
+ "access" : "readonly",
1216
+ "description" :
1217
+ """If the gmplsTunnelCHopLabelStatuses object indicates that a
1218
+ Forward Label is present and
1219
+ gmplsTunnelCHopExplicitForwardLabelPtr contains the value
1220
+ zeroDotZero, then the label to use on this hop is found in this
1221
+ object encoded as a 32-bit integer.""",
1222
+ }, # column
1223
+ "gmplsTunnelCHopExplicitForwardLabelPtr" : {
1224
+ "nodetype" : "column",
1225
+ "moduleName" : "GMPLS-TE-STD-MIB",
1226
+ "oid" : "1.3.6.1.2.1.10.166.13.2.4.1.3",
1227
+ "status" : "current",
1228
+ "syntax" : {
1229
+ "type" : { "module" :"SNMPv2-TC", "name" : "RowPointer"},
1230
+ },
1231
+ "access" : "readonly",
1232
+ "description" :
1233
+ """If the gmplsTunnelCHopLabelStatuses object indicates that a
1234
+ Forward Label is present, this object contains a pointer to a
1235
+ row in another MIB table (such as the gmplsLabelTable of
1236
+ GMPLS-LABEL-STD-MIB) that contains the label to use on this hop
1237
+ in the forward direction.
1238
+
1239
+ If the gmplsTunnelCHopLabelStatuses object indicates that a
1240
+ Forward Label is present and this object contains the value
1241
+ zeroDotZero, then the label to use on this hop is found in the
1242
+ gmplsTunnelCHopExplicitForwardLabel object.""",
1243
+ }, # column
1244
+ "gmplsTunnelCHopExplicitReverseLabel" : {
1245
+ "nodetype" : "column",
1246
+ "moduleName" : "GMPLS-TE-STD-MIB",
1247
+ "oid" : "1.3.6.1.2.1.10.166.13.2.4.1.4",
1248
+ "status" : "current",
1249
+ "syntax" : {
1250
+ "type" : { "module" :"", "name" : "Unsigned32"},
1251
+ },
1252
+ "access" : "readonly",
1253
+ "description" :
1254
+ """If the gmplsTunnelCHopLabelStatuses object indicates that a
1255
+ Reverse Label is present and
1256
+ gmplsTunnelCHopExplicitReverseLabelPtr contains the value
1257
+ zeroDotZero, then the label to use on this hop is found in this
1258
+ object encoded as a 32-bit integer.""",
1259
+ }, # column
1260
+ "gmplsTunnelCHopExplicitReverseLabelPtr" : {
1261
+ "nodetype" : "column",
1262
+ "moduleName" : "GMPLS-TE-STD-MIB",
1263
+ "oid" : "1.3.6.1.2.1.10.166.13.2.4.1.5",
1264
+ "status" : "current",
1265
+ "syntax" : {
1266
+ "type" : { "module" :"SNMPv2-TC", "name" : "RowPointer"},
1267
+ },
1268
+ "access" : "readonly",
1269
+ "description" :
1270
+ """If the gmplsTunnelCHopLabelStatuses object indicates that a
1271
+ Reverse Label is present, this object contains a pointer to a
1272
+ row in another MIB table (such as the gmplsLabelTable of
1273
+ GMPLS-LABEL-STD-MIB) that contains the label to use on this hop
1274
+ in the reverse direction.
1275
+
1276
+ If the gmplsTunnelCHopLabelStatuses object indicates that a
1277
+ Reverse Label is present and this object contains the value
1278
+ zeroDotZero, then the label to use on this hop is found in the
1279
+ gmplsTunnelCHopExplicitReverseLabel object.""",
1280
+ }, # column
1281
+ "gmplsTunnelReversePerfTable" : {
1282
+ "nodetype" : "table",
1283
+ "moduleName" : "GMPLS-TE-STD-MIB",
1284
+ "oid" : "1.3.6.1.2.1.10.166.13.2.5",
1285
+ "status" : "current",
1286
+ "description" :
1287
+ """This table augments the gmplsTunnelTable to provide
1288
+ per-tunnel packet performance information for the reverse
1289
+ direction of a bidirectional tunnel. It can be seen as
1290
+ supplementing the mplsTunnelPerfTable, which augments the
1291
+ mplsTunnelTable.
1292
+
1293
+ For links that do not transport packets, these packet counters
1294
+ cannot be maintained. For such links, attempts to read the
1295
+ objects in this table will return noSuchInstance.
1296
+
1297
+ A tunnel can be known to be bidirectional by inspecting the
1298
+ gmplsTunnelDirection object.""",
1299
+ "reference" :
1300
+ """1. Multiprotocol Label Switching (MPLS) Traffic Engineering (TE)
1301
+ Management Information Base (MIB), RFC 3812.""",
1302
+ }, # table
1303
+ "gmplsTunnelReversePerfEntry" : {
1304
+ "nodetype" : "row",
1305
+ "moduleName" : "GMPLS-TE-STD-MIB",
1306
+ "oid" : "1.3.6.1.2.1.10.166.13.2.5.1",
1307
+ "status" : "current",
1308
+ "linkage" : [
1309
+ { "GMPLS-TE-STD-MIB" : {
1310
+ "indexkind" : "augments",
1311
+ "relatedNode" : "gmplsTunnelEntry",
1312
+ }},
1313
+ ],
1314
+ "description" :
1315
+ """An entry in this table is created by the LSR for every
1316
+ bidirectional GMPLS tunnel where packets are visible to the
1317
+ LSR.""",
1318
+ }, # row
1319
+ "gmplsTunnelReversePerfPackets" : {
1320
+ "nodetype" : "column",
1321
+ "moduleName" : "GMPLS-TE-STD-MIB",
1322
+ "oid" : "1.3.6.1.2.1.10.166.13.2.5.1.1",
1323
+ "status" : "current",
1324
+ "syntax" : {
1325
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
1326
+ },
1327
+ "access" : "readonly",
1328
+ "description" :
1329
+ """Number of packets forwarded on the tunnel in the reverse
1330
+ direction if it is bidirectional.
1331
+
1332
+ This object represents the 32-bit value of the least
1333
+ significant part of the 64-bit value if both
1334
+ gmplsTunnelReversePerfHCPackets and this object are returned.
1335
+
1336
+
1337
+
1338
+
1339
+ For links that do not transport packets, this packet counter
1340
+ cannot be maintained. For such links, this value will return
1341
+ noSuchInstance.""",
1342
+ }, # column
1343
+ "gmplsTunnelReversePerfHCPackets" : {
1344
+ "nodetype" : "column",
1345
+ "moduleName" : "GMPLS-TE-STD-MIB",
1346
+ "oid" : "1.3.6.1.2.1.10.166.13.2.5.1.2",
1347
+ "status" : "current",
1348
+ "syntax" : {
1349
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter64"},
1350
+ },
1351
+ "access" : "readonly",
1352
+ "description" :
1353
+ """High-capacity counter for number of packets forwarded on the
1354
+ tunnel in the reverse direction if it is bidirectional.
1355
+
1356
+ For links that do not transport packets, this packet counter
1357
+ cannot be maintained. For such links, this value will return
1358
+ noSuchInstance.""",
1359
+ }, # column
1360
+ "gmplsTunnelReversePerfErrors" : {
1361
+ "nodetype" : "column",
1362
+ "moduleName" : "GMPLS-TE-STD-MIB",
1363
+ "oid" : "1.3.6.1.2.1.10.166.13.2.5.1.3",
1364
+ "status" : "current",
1365
+ "syntax" : {
1366
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
1367
+ },
1368
+ "access" : "readonly",
1369
+ "description" :
1370
+ """Number of errored packets received on the tunnel in the reverse
1371
+ direction if it is bidirectional. For links that do not
1372
+ transport packets, this packet counter cannot be maintained. For
1373
+ such links, this value will return noSuchInstance.""",
1374
+ }, # column
1375
+ "gmplsTunnelReversePerfBytes" : {
1376
+ "nodetype" : "column",
1377
+ "moduleName" : "GMPLS-TE-STD-MIB",
1378
+ "oid" : "1.3.6.1.2.1.10.166.13.2.5.1.4",
1379
+ "status" : "current",
1380
+ "syntax" : {
1381
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
1382
+ },
1383
+ "access" : "readonly",
1384
+ "description" :
1385
+ """Number of bytes forwarded on the tunnel in the reverse direction
1386
+ if it is bidirectional.
1387
+
1388
+ This object represents the 32-bit value of the least
1389
+ significant part of the 64-bit value if both
1390
+ gmplsTunnelReversePerfHCBytes and this object are returned.
1391
+
1392
+ For links that do not transport packets, this packet counter
1393
+ cannot be maintained. For such links, this value will return
1394
+ noSuchInstance.""",
1395
+ }, # column
1396
+ "gmplsTunnelReversePerfHCBytes" : {
1397
+ "nodetype" : "column",
1398
+ "moduleName" : "GMPLS-TE-STD-MIB",
1399
+ "oid" : "1.3.6.1.2.1.10.166.13.2.5.1.5",
1400
+ "status" : "current",
1401
+ "syntax" : {
1402
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter64"},
1403
+ },
1404
+ "access" : "readonly",
1405
+ "description" :
1406
+ """High-capacity counter for number of bytes forwarded on the
1407
+ tunnel in the reverse direction if it is bidirectional.
1408
+
1409
+ For links that do not transport packets, this packet counter
1410
+ cannot be maintained. For such links, this value will return
1411
+ noSuchInstance.""",
1412
+ }, # column
1413
+ "gmplsTunnelErrorTable" : {
1414
+ "nodetype" : "table",
1415
+ "moduleName" : "GMPLS-TE-STD-MIB",
1416
+ "oid" : "1.3.6.1.2.1.10.166.13.2.6",
1417
+ "status" : "current",
1418
+ "description" :
1419
+ """This table augments the mplsTunnelTable.
1420
+
1421
+ This table provides per-tunnel information about errors. Errors
1422
+ may be detected locally or reported through the signaling
1423
+ protocol. Error reporting is not exclusive to GMPLS, and this
1424
+ table may be applied in MPLS systems.
1425
+
1426
+ Entries in this table are not persistent over system resets
1427
+ or re-initializations of the management system.""",
1428
+ "reference" :
1429
+ """1. Multiprotocol Label Switching (MPLS) Traffic Engineering (TE)
1430
+ Management Information Base (MIB), RFC 3812.""",
1431
+ }, # table
1432
+ "gmplsTunnelErrorEntry" : {
1433
+ "nodetype" : "row",
1434
+ "moduleName" : "GMPLS-TE-STD-MIB",
1435
+ "oid" : "1.3.6.1.2.1.10.166.13.2.6.1",
1436
+ "status" : "current",
1437
+ "linkage" : [
1438
+ { "MPLS-TE-STD-MIB" : {
1439
+ "indexkind" : "augments",
1440
+ "relatedNode" : "mplsTunnelEntry",
1441
+ }},
1442
+ ],
1443
+ "description" :
1444
+ """An entry in this table is created by the LSR for every tunnel
1445
+ where error information is visible to the LSR.
1446
+
1447
+ Note that systems that read the objects in this table one at
1448
+ a time and do not perform atomic operations to read entire
1449
+ instantiated table rows at once, should, for each conceptual
1450
+ column with valid data, read gmplsTunnelErrorLastTime
1451
+ prior to the other objects in the row and again subsequent to
1452
+ reading the last object of the row. They should verify that
1453
+ the value of gmplsTunnelErrorLastTime did not change and
1454
+ thereby ensure that all data read belongs to the same error
1455
+ event.""",
1456
+ }, # row
1457
+ "gmplsTunnelErrorLastErrorType" : {
1458
+ "nodetype" : "column",
1459
+ "moduleName" : "GMPLS-TE-STD-MIB",
1460
+ "oid" : "1.3.6.1.2.1.10.166.13.2.6.1.1",
1461
+ "status" : "current",
1462
+ "syntax" : {
1463
+ "type" : {
1464
+ "basetype" : "Enumeration",
1465
+ "noError" : {
1466
+ "nodetype" : "namednumber",
1467
+ "number" : "0"
1468
+ },
1469
+ "unknown" : {
1470
+ "nodetype" : "namednumber",
1471
+ "number" : "1"
1472
+ },
1473
+ "protocol" : {
1474
+ "nodetype" : "namednumber",
1475
+ "number" : "2"
1476
+ },
1477
+ "pathComputation" : {
1478
+ "nodetype" : "namednumber",
1479
+ "number" : "3"
1480
+ },
1481
+ "localConfiguration" : {
1482
+ "nodetype" : "namednumber",
1483
+ "number" : "4"
1484
+ },
1485
+ "localResources" : {
1486
+ "nodetype" : "namednumber",
1487
+ "number" : "5"
1488
+ },
1489
+ "localOther" : {
1490
+ "nodetype" : "namednumber",
1491
+ "number" : "6"
1492
+ },
1493
+ },
1494
+ },
1495
+ "access" : "readonly",
1496
+ "description" :
1497
+ """The nature of the last error. Provides interpretation context
1498
+ for gmplsTunnelErrorProtocolCode and
1499
+ gmplsTunnelErrorProtocolSubcode.
1500
+
1501
+ A value of noError(0) shows that there is no error associated
1502
+ with this tunnel and means that the other objects in this table
1503
+ entry (conceptual row) have no meaning.
1504
+
1505
+ A value of unknown(1) shows that there is an error but that no
1506
+ additional information about the cause is known. The error may
1507
+ have been received in a signaled message or generated locally.
1508
+
1509
+ A value of protocol(2) or pathComputation(3) indicates the
1510
+ cause of an error and identifies an error that has been received
1511
+ through signaling or will itself be signaled.
1512
+
1513
+ A value of localConfiguration(4), localResources(5) or
1514
+ localOther(6) identifies an error that has been detected
1515
+ by the local node but that will not be reported through
1516
+ signaling.""",
1517
+ }, # column
1518
+ "gmplsTunnelErrorLastTime" : {
1519
+ "nodetype" : "column",
1520
+ "moduleName" : "GMPLS-TE-STD-MIB",
1521
+ "oid" : "1.3.6.1.2.1.10.166.13.2.6.1.2",
1522
+ "status" : "current",
1523
+ "syntax" : {
1524
+ "type" : { "module" :"SNMPv2-TC", "name" : "TimeStamp"},
1525
+ },
1526
+ "access" : "readonly",
1527
+ "description" :
1528
+ """The time at which the last error occurred. This is presented as
1529
+ the value of SysUpTime when the error occurred or was reported
1530
+ to this node.
1531
+
1532
+ If gmplsTunnelErrorLastErrorType has the value noError(0), then
1533
+ this object is not valid and should be ignored.
1534
+
1535
+ Note that entries in this table are not persistent over system
1536
+ resets or re-initializations of the management system.""",
1537
+ }, # column
1538
+ "gmplsTunnelErrorReporterType" : {
1539
+ "nodetype" : "column",
1540
+ "moduleName" : "GMPLS-TE-STD-MIB",
1541
+ "oid" : "1.3.6.1.2.1.10.166.13.2.6.1.3",
1542
+ "status" : "current",
1543
+ "syntax" : {
1544
+ "type" : { "module" :"INET-ADDRESS-MIB", "name" : "InetAddressType"},
1545
+ },
1546
+ "access" : "readonly",
1547
+ "description" :
1548
+ """The address type of the error reported.
1549
+
1550
+ This object is used to aid in interpretation of
1551
+ gmplsTunnelErrorReporter.""",
1552
+ }, # column
1553
+ "gmplsTunnelErrorReporter" : {
1554
+ "nodetype" : "column",
1555
+ "moduleName" : "GMPLS-TE-STD-MIB",
1556
+ "oid" : "1.3.6.1.2.1.10.166.13.2.6.1.4",
1557
+ "status" : "current",
1558
+ "syntax" : {
1559
+ "type" : { "module" :"INET-ADDRESS-MIB", "name" : "InetAddress"},
1560
+ },
1561
+ "access" : "readonly",
1562
+ "description" :
1563
+ """The address of the node reporting the last error, or the address
1564
+ of the resource (such as an interface) associated with the
1565
+ error.
1566
+
1567
+ If gmplsTunnelErrorLastErrorType has the value noError(0), then
1568
+ this object is not valid and should be ignored.
1569
+
1570
+ If gmplsTunnelErrorLastErrorType has the value unknown(1),
1571
+ localConfiguration(4), localResources(5), or localOther(6),
1572
+ this object MAY contain a zero value.
1573
+
1574
+ This object should be interpreted in the context of the value of
1575
+ the object gmplsTunnelErrorReporterType.""",
1576
+ "reference" :
1577
+ """1. Textual Conventions for Internet Network Addresses, RFC 4001,
1578
+ section 4, Usage Hints.""",
1579
+ }, # column
1580
+ "gmplsTunnelErrorCode" : {
1581
+ "nodetype" : "column",
1582
+ "moduleName" : "GMPLS-TE-STD-MIB",
1583
+ "oid" : "1.3.6.1.2.1.10.166.13.2.6.1.5",
1584
+ "status" : "current",
1585
+ "syntax" : {
1586
+ "type" : { "module" :"", "name" : "Unsigned32"},
1587
+ },
1588
+ "access" : "readonly",
1589
+ "description" :
1590
+ """The primary error code associated with the last error.
1591
+
1592
+ The interpretation of this error code depends on the value of
1593
+ gmplsTunnelErrorLastErrorType. If the value of
1594
+ gmplsTunnelErrorLastErrorType is noError(0), the value of this
1595
+ object should be 0 and should be ignored. If the value of
1596
+ gmplsTunnelErrorLastErrorType is protocol(2), the error should
1597
+ be interpreted in the context of the signaling protocol
1598
+ identified by the mplsTunnelSignallingProto object.""",
1599
+ "reference" :
1600
+ """1. Resource ReserVation Protocol -- Version 1 Functional
1601
+ Specification, RFC 2205, section B.
1602
+ 2. RSVP-TE: Extensions to RSVP for LSP Tunnels, RFC 3209,
1603
+ section 7.3.
1604
+ 3. Generalized MPLS Signaling - RSVP-TE Extensions, RFC 3473,
1605
+ section 13.1.""",
1606
+ }, # column
1607
+ "gmplsTunnelErrorSubcode" : {
1608
+ "nodetype" : "column",
1609
+ "moduleName" : "GMPLS-TE-STD-MIB",
1610
+ "oid" : "1.3.6.1.2.1.10.166.13.2.6.1.6",
1611
+ "status" : "current",
1612
+ "syntax" : {
1613
+ "type" : { "module" :"", "name" : "Unsigned32"},
1614
+ },
1615
+ "access" : "readonly",
1616
+ "description" :
1617
+ """The secondary error code associated with the last error and the
1618
+ protocol used to signal this tunnel. This value is interpreted
1619
+ in the context of the value of gmplsTunnelErrorCode.
1620
+ If the value of gmplsTunnelErrorLastErrorType is noError(0), the
1621
+ value of this object should be 0 and should be ignored.""",
1622
+ "reference" :
1623
+ """1. Resource ReserVation Protocol -- Version 1 Functional
1624
+ Specification, RFC 2205, section B.
1625
+ 2. RSVP-TE: Extensions to RSVP for LSP Tunnels, RFC 3209,
1626
+ section 7.3.
1627
+ 3. Generalized MPLS Signaling - RSVP-TE Extensions, RFC 3473,
1628
+ section 13.1. """,
1629
+ }, # column
1630
+ "gmplsTunnelErrorTLVs" : {
1631
+ "nodetype" : "column",
1632
+ "moduleName" : "GMPLS-TE-STD-MIB",
1633
+ "oid" : "1.3.6.1.2.1.10.166.13.2.6.1.7",
1634
+ "status" : "current",
1635
+ "syntax" : {
1636
+ "type" : {
1637
+ "basetype" : "OctetString",
1638
+ "ranges" : [
1639
+ {
1640
+ "min" : "0",
1641
+ "max" : "65535"
1642
+ },
1643
+ ],
1644
+ "range" : {
1645
+ "min" : "0",
1646
+ "max" : "65535"
1647
+ },
1648
+ },
1649
+ },
1650
+ "access" : "readonly",
1651
+ "description" :
1652
+ """The sequence of interface identifier TLVs reported with the
1653
+ error by the protocol code. The interpretation of the TLVs and
1654
+ the encoding within the protocol are described in the
1655
+ references. A value of zero in the first octet indicates that no
1656
+ TLVs are present.""",
1657
+ "reference" :
1658
+ """1. Generalized MPLS Signaling - RSVP-TE Extensions, RFC 3473,
1659
+ section 8.2.""",
1660
+ }, # column
1661
+ "gmplsTunnelErrorHelpString" : {
1662
+ "nodetype" : "column",
1663
+ "moduleName" : "GMPLS-TE-STD-MIB",
1664
+ "oid" : "1.3.6.1.2.1.10.166.13.2.6.1.8",
1665
+ "status" : "current",
1666
+ "syntax" : {
1667
+ "type" : { "module" :"SNMP-FRAMEWORK-MIB", "name" : "SnmpAdminString"},
1668
+ },
1669
+ "access" : "readonly",
1670
+ "description" :
1671
+ """A textual string containing information about the last error,
1672
+ recovery actions, and support advice. If there is no help string,
1673
+ this object contains a zero length string.
1674
+ If the value of gmplsTunnelErrorLastErrorType is noError(0),
1675
+ this object should contain a zero length string, but may contain
1676
+ a help string indicating that there is no error.""",
1677
+ }, # column
1678
+ "gmplsTeConformance" : {
1679
+ "nodetype" : "node",
1680
+ "moduleName" : "GMPLS-TE-STD-MIB",
1681
+ "oid" : "1.3.6.1.2.1.10.166.13.3",
1682
+ }, # node
1683
+ "gmplsTeGroups" : {
1684
+ "nodetype" : "node",
1685
+ "moduleName" : "GMPLS-TE-STD-MIB",
1686
+ "oid" : "1.3.6.1.2.1.10.166.13.3.1",
1687
+ }, # node
1688
+ "gmplsTeCompliances" : {
1689
+ "nodetype" : "node",
1690
+ "moduleName" : "GMPLS-TE-STD-MIB",
1691
+ "oid" : "1.3.6.1.2.1.10.166.13.3.2",
1692
+ }, # node
1693
+ }, # nodes
1694
+
1695
+ "notifications" : {
1696
+ "gmplsTunnelDown" : {
1697
+ "nodetype" : "notification",
1698
+ "moduleName" : "GMPLS-TE-STD-MIB",
1699
+ "oid" : "1.3.6.1.2.1.10.166.13.0.1",
1700
+ "status" : "current",
1701
+ "objects" : {
1702
+ "mplsTunnelAdminStatus" : {
1703
+ "nodetype" : "object",
1704
+ "module" : "MPLS-TE-STD-MIB"
1705
+ },
1706
+ "mplsTunnelOperStatus" : {
1707
+ "nodetype" : "object",
1708
+ "module" : "MPLS-TE-STD-MIB"
1709
+ },
1710
+ "gmplsTunnelErrorLastErrorType" : {
1711
+ "nodetype" : "object",
1712
+ "module" : "GMPLS-TE-STD-MIB"
1713
+ },
1714
+ "gmplsTunnelErrorReporterType" : {
1715
+ "nodetype" : "object",
1716
+ "module" : "GMPLS-TE-STD-MIB"
1717
+ },
1718
+ "gmplsTunnelErrorReporter" : {
1719
+ "nodetype" : "object",
1720
+ "module" : "GMPLS-TE-STD-MIB"
1721
+ },
1722
+ "gmplsTunnelErrorCode" : {
1723
+ "nodetype" : "object",
1724
+ "module" : "GMPLS-TE-STD-MIB"
1725
+ },
1726
+ "gmplsTunnelErrorSubcode" : {
1727
+ "nodetype" : "object",
1728
+ "module" : "GMPLS-TE-STD-MIB"
1729
+ },
1730
+ },
1731
+ "description" :
1732
+ """This notification is generated when an mplsTunnelOperStatus
1733
+ object for a tunnel in the gmplsTunnelTable is about to enter
1734
+ the down state from some other state (but not from the
1735
+ notPresent state). This other state is indicated by the
1736
+ included value of mplsTunnelOperStatus.
1737
+
1738
+ The objects in this notification provide additional error
1739
+ information that indicates the reason why the tunnel has
1740
+
1741
+
1742
+
1743
+ transitioned to down(2).
1744
+
1745
+ Note that an implementation MUST only issue one of
1746
+ mplsTunnelDown and gmplsTunnelDown for any single event on a
1747
+ single tunnel. If the tunnel has an entry in the
1748
+ gmplsTunnelTable, an implementation SHOULD use gmplsTunnelDown
1749
+ for all tunnel-down events and SHOULD NOT use mplsTunnelDown.
1750
+
1751
+ This notification is subject to the control of
1752
+ mplsTunnelNotificationEnable. When that object is set
1753
+ to false(2), then the notification must not be issued.
1754
+
1755
+ Further, this notification is also subject to
1756
+ mplsTunnelNotificationMaxRate. That object indicates the
1757
+ maximum number of notifications issued per second. If events
1758
+ occur more rapidly, the implementation may simply fail to emit
1759
+ some notifications during that period, or may queue them until
1760
+ an appropriate time. The notification rate applies to the sum
1761
+ of all notifications in the MPLS-TE-STD-MIB and
1762
+ GMPLS-TE-STD-MIB modules applied across the whole of the
1763
+ reporting device.
1764
+
1765
+ mplsTunnelOperStatus, mplsTunnelAdminStatus, mplsTunnelDown,
1766
+ mplsTunnelNotificationEnable, and mplsTunnelNotificationMaxRate
1767
+ objects are found in MPLS-TE-STD-MIB.""",
1768
+ "reference" :
1769
+ """1. Multiprotocol Label Switching (MPLS) Traffic Engineering
1770
+ (TE) Management Information Base (MIB), RFC 3812.""",
1771
+ }, # notification
1772
+ }, # notifications
1773
+
1774
+ "groups" : {
1775
+ "gmplsTunnelGroup" : {
1776
+ "nodetype" : "group",
1777
+ "moduleName" : "GMPLS-TE-STD-MIB",
1778
+ "oid" : "1.3.6.1.2.1.10.166.13.3.1.1",
1779
+ "status" : "current",
1780
+ "members" : {
1781
+ "gmplsTunnelDirection" : {
1782
+ "nodetype" : "member",
1783
+ "module" : "GMPLS-TE-STD-MIB"
1784
+ },
1785
+ "gmplsTunnelReversePerfPackets" : {
1786
+ "nodetype" : "member",
1787
+ "module" : "GMPLS-TE-STD-MIB"
1788
+ },
1789
+ "gmplsTunnelReversePerfHCPackets" : {
1790
+ "nodetype" : "member",
1791
+ "module" : "GMPLS-TE-STD-MIB"
1792
+ },
1793
+ "gmplsTunnelReversePerfErrors" : {
1794
+ "nodetype" : "member",
1795
+ "module" : "GMPLS-TE-STD-MIB"
1796
+ },
1797
+ "gmplsTunnelReversePerfBytes" : {
1798
+ "nodetype" : "member",
1799
+ "module" : "GMPLS-TE-STD-MIB"
1800
+ },
1801
+ "gmplsTunnelReversePerfHCBytes" : {
1802
+ "nodetype" : "member",
1803
+ "module" : "GMPLS-TE-STD-MIB"
1804
+ },
1805
+ "gmplsTunnelErrorLastErrorType" : {
1806
+ "nodetype" : "member",
1807
+ "module" : "GMPLS-TE-STD-MIB"
1808
+ },
1809
+ "gmplsTunnelErrorLastTime" : {
1810
+ "nodetype" : "member",
1811
+ "module" : "GMPLS-TE-STD-MIB"
1812
+ },
1813
+ "gmplsTunnelErrorReporterType" : {
1814
+ "nodetype" : "member",
1815
+ "module" : "GMPLS-TE-STD-MIB"
1816
+ },
1817
+ "gmplsTunnelErrorReporter" : {
1818
+ "nodetype" : "member",
1819
+ "module" : "GMPLS-TE-STD-MIB"
1820
+ },
1821
+ "gmplsTunnelErrorCode" : {
1822
+ "nodetype" : "member",
1823
+ "module" : "GMPLS-TE-STD-MIB"
1824
+ },
1825
+ "gmplsTunnelErrorSubcode" : {
1826
+ "nodetype" : "member",
1827
+ "module" : "GMPLS-TE-STD-MIB"
1828
+ },
1829
+ "gmplsTunnelErrorTLVs" : {
1830
+ "nodetype" : "member",
1831
+ "module" : "GMPLS-TE-STD-MIB"
1832
+ },
1833
+ "gmplsTunnelErrorHelpString" : {
1834
+ "nodetype" : "member",
1835
+ "module" : "GMPLS-TE-STD-MIB"
1836
+ },
1837
+ "gmplsTunnelUnnumIf" : {
1838
+ "nodetype" : "member",
1839
+ "module" : "GMPLS-TE-STD-MIB"
1840
+ },
1841
+ }, # members
1842
+ "description" :
1843
+ """Necessary, but not sufficient, set of objects to implement
1844
+ tunnels. In addition, depending on the type of the tunnels
1845
+ supported (for example, manually configured or signaled,
1846
+ persistent or non-persistent, etc.), the
1847
+ gmplsTunnelSignaledGroup group is mandatory.""",
1848
+ }, # group
1849
+ "gmplsTunnelSignaledGroup" : {
1850
+ "nodetype" : "group",
1851
+ "moduleName" : "GMPLS-TE-STD-MIB",
1852
+ "oid" : "1.3.6.1.2.1.10.166.13.3.1.2",
1853
+ "status" : "current",
1854
+ "members" : {
1855
+ "gmplsTunnelAttributes" : {
1856
+ "nodetype" : "member",
1857
+ "module" : "GMPLS-TE-STD-MIB"
1858
+ },
1859
+ "gmplsTunnelLSPEncoding" : {
1860
+ "nodetype" : "member",
1861
+ "module" : "GMPLS-TE-STD-MIB"
1862
+ },
1863
+ "gmplsTunnelSwitchingType" : {
1864
+ "nodetype" : "member",
1865
+ "module" : "GMPLS-TE-STD-MIB"
1866
+ },
1867
+ "gmplsTunnelLinkProtection" : {
1868
+ "nodetype" : "member",
1869
+ "module" : "GMPLS-TE-STD-MIB"
1870
+ },
1871
+ "gmplsTunnelGPid" : {
1872
+ "nodetype" : "member",
1873
+ "module" : "GMPLS-TE-STD-MIB"
1874
+ },
1875
+ "gmplsTunnelSecondary" : {
1876
+ "nodetype" : "member",
1877
+ "module" : "GMPLS-TE-STD-MIB"
1878
+ },
1879
+ "gmplsTunnelPathComp" : {
1880
+ "nodetype" : "member",
1881
+ "module" : "GMPLS-TE-STD-MIB"
1882
+ },
1883
+ "gmplsTunnelUpstreamNotifyRecipientType" : {
1884
+ "nodetype" : "member",
1885
+ "module" : "GMPLS-TE-STD-MIB"
1886
+ },
1887
+ "gmplsTunnelUpstreamNotifyRecipient" : {
1888
+ "nodetype" : "member",
1889
+ "module" : "GMPLS-TE-STD-MIB"
1890
+ },
1891
+ "gmplsTunnelSendResvNotifyRecipientType" : {
1892
+ "nodetype" : "member",
1893
+ "module" : "GMPLS-TE-STD-MIB"
1894
+ },
1895
+ "gmplsTunnelSendResvNotifyRecipient" : {
1896
+ "nodetype" : "member",
1897
+ "module" : "GMPLS-TE-STD-MIB"
1898
+ },
1899
+ "gmplsTunnelDownstreamNotifyRecipientType" : {
1900
+ "nodetype" : "member",
1901
+ "module" : "GMPLS-TE-STD-MIB"
1902
+ },
1903
+ "gmplsTunnelDownstreamNotifyRecipient" : {
1904
+ "nodetype" : "member",
1905
+ "module" : "GMPLS-TE-STD-MIB"
1906
+ },
1907
+ "gmplsTunnelSendPathNotifyRecipientType" : {
1908
+ "nodetype" : "member",
1909
+ "module" : "GMPLS-TE-STD-MIB"
1910
+ },
1911
+ "gmplsTunnelSendPathNotifyRecipient" : {
1912
+ "nodetype" : "member",
1913
+ "module" : "GMPLS-TE-STD-MIB"
1914
+ },
1915
+ "gmplsTunnelAdminStatusFlags" : {
1916
+ "nodetype" : "member",
1917
+ "module" : "GMPLS-TE-STD-MIB"
1918
+ },
1919
+ "gmplsTunnelHopLabelStatuses" : {
1920
+ "nodetype" : "member",
1921
+ "module" : "GMPLS-TE-STD-MIB"
1922
+ },
1923
+ "gmplsTunnelHopExplicitForwardLabel" : {
1924
+ "nodetype" : "member",
1925
+ "module" : "GMPLS-TE-STD-MIB"
1926
+ },
1927
+ "gmplsTunnelHopExplicitForwardLabelPtr" : {
1928
+ "nodetype" : "member",
1929
+ "module" : "GMPLS-TE-STD-MIB"
1930
+ },
1931
+ "gmplsTunnelHopExplicitReverseLabel" : {
1932
+ "nodetype" : "member",
1933
+ "module" : "GMPLS-TE-STD-MIB"
1934
+ },
1935
+ "gmplsTunnelHopExplicitReverseLabelPtr" : {
1936
+ "nodetype" : "member",
1937
+ "module" : "GMPLS-TE-STD-MIB"
1938
+ },
1939
+ }, # members
1940
+ "description" :
1941
+ """Objects needed to implement signaled tunnels.""",
1942
+ }, # group
1943
+ "gmplsTunnelScalarGroup" : {
1944
+ "nodetype" : "group",
1945
+ "moduleName" : "GMPLS-TE-STD-MIB",
1946
+ "oid" : "1.3.6.1.2.1.10.166.13.3.1.3",
1947
+ "status" : "current",
1948
+ "members" : {
1949
+ "gmplsTunnelsConfigured" : {
1950
+ "nodetype" : "member",
1951
+ "module" : "GMPLS-TE-STD-MIB"
1952
+ },
1953
+ "gmplsTunnelsActive" : {
1954
+ "nodetype" : "member",
1955
+ "module" : "GMPLS-TE-STD-MIB"
1956
+ },
1957
+ }, # members
1958
+ "description" :
1959
+ """Scalar objects needed to implement MPLS tunnels.""",
1960
+ }, # group
1961
+ "gmplsTunnelOptionalGroup" : {
1962
+ "nodetype" : "group",
1963
+ "moduleName" : "GMPLS-TE-STD-MIB",
1964
+ "oid" : "1.3.6.1.2.1.10.166.13.3.1.4",
1965
+ "status" : "current",
1966
+ "members" : {
1967
+ "gmplsTunnelExtraParamsPtr" : {
1968
+ "nodetype" : "member",
1969
+ "module" : "GMPLS-TE-STD-MIB"
1970
+ },
1971
+ "gmplsTunnelARHopLabelStatuses" : {
1972
+ "nodetype" : "member",
1973
+ "module" : "GMPLS-TE-STD-MIB"
1974
+ },
1975
+ "gmplsTunnelARHopExplicitForwardLabel" : {
1976
+ "nodetype" : "member",
1977
+ "module" : "GMPLS-TE-STD-MIB"
1978
+ },
1979
+ "gmplsTunnelARHopExplicitForwardLabelPtr" : {
1980
+ "nodetype" : "member",
1981
+ "module" : "GMPLS-TE-STD-MIB"
1982
+ },
1983
+ "gmplsTunnelARHopExplicitReverseLabel" : {
1984
+ "nodetype" : "member",
1985
+ "module" : "GMPLS-TE-STD-MIB"
1986
+ },
1987
+ "gmplsTunnelARHopExplicitReverseLabelPtr" : {
1988
+ "nodetype" : "member",
1989
+ "module" : "GMPLS-TE-STD-MIB"
1990
+ },
1991
+ "gmplsTunnelARHopProtection" : {
1992
+ "nodetype" : "member",
1993
+ "module" : "GMPLS-TE-STD-MIB"
1994
+ },
1995
+ "gmplsTunnelCHopLabelStatuses" : {
1996
+ "nodetype" : "member",
1997
+ "module" : "GMPLS-TE-STD-MIB"
1998
+ },
1999
+ "gmplsTunnelCHopExplicitForwardLabel" : {
2000
+ "nodetype" : "member",
2001
+ "module" : "GMPLS-TE-STD-MIB"
2002
+ },
2003
+ "gmplsTunnelCHopExplicitForwardLabelPtr" : {
2004
+ "nodetype" : "member",
2005
+ "module" : "GMPLS-TE-STD-MIB"
2006
+ },
2007
+ "gmplsTunnelCHopExplicitReverseLabel" : {
2008
+ "nodetype" : "member",
2009
+ "module" : "GMPLS-TE-STD-MIB"
2010
+ },
2011
+ "gmplsTunnelCHopExplicitReverseLabelPtr" : {
2012
+ "nodetype" : "member",
2013
+ "module" : "GMPLS-TE-STD-MIB"
2014
+ },
2015
+ }, # members
2016
+ "description" :
2017
+ """The objects in this group are optional.""",
2018
+ }, # group
2019
+ "gmplsTeNotificationGroup" : {
2020
+ "nodetype" : "group",
2021
+ "moduleName" : "GMPLS-TE-STD-MIB",
2022
+ "oid" : "1.3.6.1.2.1.10.166.13.3.1.5",
2023
+ "status" : "current",
2024
+ "members" : {
2025
+ "gmplsTunnelDown" : {
2026
+ "nodetype" : "member",
2027
+ "module" : "GMPLS-TE-STD-MIB"
2028
+ },
2029
+ }, # members
2030
+ "description" :
2031
+ """Set of notifications implemented in this module. None is
2032
+ mandatory.""",
2033
+ }, # group
2034
+ }, # groups
2035
+
2036
+ "compliances" : {
2037
+ "gmplsTeModuleFullCompliance" : {
2038
+ "nodetype" : "compliance",
2039
+ "moduleName" : "GMPLS-TE-STD-MIB",
2040
+ "oid" : "1.3.6.1.2.1.10.166.13.3.2.1",
2041
+ "status" : "current",
2042
+ "description" :
2043
+ """Compliance statement for agents that provide full support for
2044
+ GMPLS-TE-STD-MIB. Such devices can then be monitored and also
2045
+ be configured using this MIB module.
2046
+
2047
+ The mandatory group has to be implemented by all LSRs that
2048
+ originate, terminate, or act as transit for TE-LSPs/tunnels.
2049
+ In addition, depending on the type of tunnels supported, other
2050
+
2051
+
2052
+
2053
+ groups become mandatory as explained below.""",
2054
+ "requires" : {
2055
+ "mplsTunnelGroup" : {
2056
+ "nodetype" : "mandatory",
2057
+ "module" : "MPLS-TE-STD-MIB"
2058
+ },
2059
+ "mplsTunnelScalarGroup" : {
2060
+ "nodetype" : "mandatory",
2061
+ "module" : "MPLS-TE-STD-MIB"
2062
+ },
2063
+ "gmplsTunnelGroup" : {
2064
+ "nodetype" : "mandatory",
2065
+ "module" : "GMPLS-TE-STD-MIB"
2066
+ },
2067
+ "gmplsTunnelScalarGroup" : {
2068
+ "nodetype" : "mandatory",
2069
+ "module" : "GMPLS-TE-STD-MIB"
2070
+ },
2071
+ "gmplsTunnelSignaledGroup" : {
2072
+ "nodetype" : "optional",
2073
+ "module" : "GMPLS-TE-STD-MIB",
2074
+ "description" :
2075
+ """This group is mandatory for devices that support signaled
2076
+ tunnel set up, in addition to gmplsTunnelGroup. The following
2077
+ constraints apply:
2078
+ mplsTunnelSignallingProto should be at least read-only
2079
+ returning a value of ldp(2) or rsvp(3).""",
2080
+ },
2081
+ "gmplsTunnelOptionalGroup" : {
2082
+ "nodetype" : "optional",
2083
+ "module" : "GMPLS-TE-STD-MIB",
2084
+ "description" :
2085
+ """Objects in this group are optional.""",
2086
+ },
2087
+ "gmplsTeNotificationGroup" : {
2088
+ "nodetype" : "optional",
2089
+ "module" : "GMPLS-TE-STD-MIB",
2090
+ "description" :
2091
+ """This group is mandatory for those implementations that can
2092
+ implement the notifications contained in this group.""",
2093
+ },
2094
+ }, # requires
2095
+ }, # compliance
2096
+ "gmplsTeModuleReadOnlyCompliance" : {
2097
+ "nodetype" : "compliance",
2098
+ "moduleName" : "GMPLS-TE-STD-MIB",
2099
+ "oid" : "1.3.6.1.2.1.10.166.13.3.2.2",
2100
+ "status" : "current",
2101
+ "description" :
2102
+ """Compliance requirement for implementations that only provide
2103
+ read-only support for GMPLS-TE-STD-MIB. Such devices can then be
2104
+ monitored but cannot be configured using this MIB module.""",
2105
+ "requires" : {
2106
+ "gmplsTunnelGroup" : {
2107
+ "nodetype" : "mandatory",
2108
+ "module" : "GMPLS-TE-STD-MIB"
2109
+ },
2110
+ "gmplsTunnelScalarGroup" : {
2111
+ "nodetype" : "mandatory",
2112
+ "module" : "GMPLS-TE-STD-MIB"
2113
+ },
2114
+ "gmplsTunnelSignaledGroup" : {
2115
+ "nodetype" : "optional",
2116
+ "module" : "GMPLS-TE-STD-MIB",
2117
+ "description" :
2118
+ """This group is mandatory for devices that support signaled
2119
+ tunnel set up, in addition to gmplsTunnelGroup. The following
2120
+ constraints apply:
2121
+ mplsTunnelSignallingProto should be at least read-only
2122
+ returning a value of ldp(2) or rsvp(3).""",
2123
+ },
2124
+ "gmplsTunnelOptionalGroup" : {
2125
+ "nodetype" : "optional",
2126
+ "module" : "GMPLS-TE-STD-MIB",
2127
+ "description" :
2128
+ """Objects in this group are optional.""",
2129
+ },
2130
+ "gmplsTeNotificationGroup" : {
2131
+ "nodetype" : "optional",
2132
+ "module" : "GMPLS-TE-STD-MIB",
2133
+ "description" :
2134
+ """This group is mandatory for those implementations that can
2135
+ implement the notifications contained in this group.""",
2136
+ },
2137
+ }, # requires
2138
+ "refinements" : {
2139
+ "gmplsTunnelUnnumIf" : {
2140
+ "module" : "GMPLS-TE-STD-MIB",
2141
+ "access" : "readonly",
2142
+ "description" :
2143
+ """Write access is not required.""",
2144
+ },
2145
+ "gmplsTunnelAttributes" : {
2146
+ "module" : "GMPLS-TE-STD-MIB",
2147
+ "access" : "readonly",
2148
+ "description" :
2149
+ """Write access is not required.""",
2150
+ },
2151
+ "gmplsTunnelLSPEncoding" : {
2152
+ "module" : "GMPLS-TE-STD-MIB",
2153
+ "access" : "readonly",
2154
+ "description" :
2155
+ """Write access is not required.""",
2156
+ },
2157
+ "gmplsTunnelSwitchingType" : {
2158
+ "module" : "GMPLS-TE-STD-MIB",
2159
+ "access" : "readonly",
2160
+ "description" :
2161
+ """Write access is not required.""",
2162
+ },
2163
+ "gmplsTunnelLinkProtection" : {
2164
+ "module" : "GMPLS-TE-STD-MIB",
2165
+ "access" : "readonly",
2166
+ "description" :
2167
+ """Write access is not required.""",
2168
+ },
2169
+ "gmplsTunnelGPid" : {
2170
+ "module" : "GMPLS-TE-STD-MIB",
2171
+ "access" : "readonly",
2172
+ "description" :
2173
+ """Write access is not required.""",
2174
+ },
2175
+ "gmplsTunnelSecondary" : {
2176
+ "module" : "GMPLS-TE-STD-MIB",
2177
+ "access" : "readonly",
2178
+ "description" :
2179
+ """Write access is not required.""",
2180
+ },
2181
+ "gmplsTunnelDirection" : {
2182
+ "module" : "GMPLS-TE-STD-MIB",
2183
+ "access" : "readonly",
2184
+ "description" :
2185
+ """Only forward(0) is required.""",
2186
+ },
2187
+ "gmplsTunnelPathComp" : {
2188
+ "module" : "GMPLS-TE-STD-MIB",
2189
+ "access" : "readonly",
2190
+ "description" :
2191
+ """Only explicit(2) is required.""",
2192
+ },
2193
+ "gmplsTunnelUpstreamNotifyRecipientType" : {
2194
+ "module" : "GMPLS-TE-STD-MIB",
2195
+ "syntax" : {
2196
+ "type" : {
2197
+ "basetype" : "Enumeration",
2198
+ "parent module" : {
2199
+ "name" : "INET-ADDRESS-MIB",
2200
+ "type" : "InetAddressType",
2201
+ },
2202
+ "unknown" : {
2203
+ "nodetype" : "namednumber",
2204
+ "number" : "0"
2205
+ },
2206
+ "ipv4" : {
2207
+ "nodetype" : "namednumber",
2208
+ "number" : "1"
2209
+ },
2210
+ "ipv6" : {
2211
+ "nodetype" : "namednumber",
2212
+ "number" : "2"
2213
+ },
2214
+ },
2215
+ }, # syntax
2216
+ "access" : "readonly",
2217
+ "description" :
2218
+ """Only unknown(0), ipv4(1), and ipv6(2) support
2219
+ is required.""",
2220
+ },
2221
+ "gmplsTunnelUpstreamNotifyRecipient" : {
2222
+ "module" : "GMPLS-TE-STD-MIB",
2223
+ "syntax" : {
2224
+ "type" : {
2225
+ "basetype" : "OctetString",
2226
+ "parent module" : {
2227
+ "name" : "INET-ADDRESS-MIB",
2228
+ "type" : "InetAddress",
2229
+ },
2230
+ "ranges" : [
2231
+ {
2232
+ "min" : "0",
2233
+ "max" : "0"
2234
+ },
2235
+ {
2236
+ "min" : "4",
2237
+ "max" : "4"
2238
+ },
2239
+ {
2240
+ "min" : "16",
2241
+ "max" : "16"
2242
+ },
2243
+ ],
2244
+ "range" : {
2245
+ "min" : "0",
2246
+ "max" : "16"
2247
+ },
2248
+ },
2249
+ }, # syntax
2250
+ "access" : "readonly",
2251
+ "description" :
2252
+ """An implementation is only required to support
2253
+ unknown(0), ipv4(1), and ipv6(2) sizes.""",
2254
+ },
2255
+ "gmplsTunnelSendResvNotifyRecipientType" : {
2256
+ "module" : "GMPLS-TE-STD-MIB",
2257
+ "syntax" : {
2258
+ "type" : {
2259
+ "basetype" : "Enumeration",
2260
+ "parent module" : {
2261
+ "name" : "INET-ADDRESS-MIB",
2262
+ "type" : "InetAddressType",
2263
+ },
2264
+ "unknown" : {
2265
+ "nodetype" : "namednumber",
2266
+ "number" : "0"
2267
+ },
2268
+ "ipv4" : {
2269
+ "nodetype" : "namednumber",
2270
+ "number" : "1"
2271
+ },
2272
+ "ipv6" : {
2273
+ "nodetype" : "namednumber",
2274
+ "number" : "2"
2275
+ },
2276
+ },
2277
+ }, # syntax
2278
+ "access" : "readonly",
2279
+ "description" :
2280
+ """Only unknown(0), ipv4(1), and ipv6(2) support
2281
+ is required.""",
2282
+ },
2283
+ "gmplsTunnelSendResvNotifyRecipient" : {
2284
+ "module" : "GMPLS-TE-STD-MIB",
2285
+ "syntax" : {
2286
+ "type" : {
2287
+ "basetype" : "OctetString",
2288
+ "parent module" : {
2289
+ "name" : "INET-ADDRESS-MIB",
2290
+ "type" : "InetAddress",
2291
+ },
2292
+ "ranges" : [
2293
+ {
2294
+ "min" : "0",
2295
+ "max" : "0"
2296
+ },
2297
+ {
2298
+ "min" : "4",
2299
+ "max" : "4"
2300
+ },
2301
+ {
2302
+ "min" : "16",
2303
+ "max" : "16"
2304
+ },
2305
+ ],
2306
+ "range" : {
2307
+ "min" : "0",
2308
+ "max" : "16"
2309
+ },
2310
+ },
2311
+ }, # syntax
2312
+ "access" : "readonly",
2313
+ "description" :
2314
+ """An implementation is only required to support
2315
+ unknown(0), ipv4(1), and ipv6(2) sizes.""",
2316
+ },
2317
+ "gmplsTunnelDownstreamNotifyRecipientType" : {
2318
+ "module" : "GMPLS-TE-STD-MIB",
2319
+ "syntax" : {
2320
+ "type" : {
2321
+ "basetype" : "Enumeration",
2322
+ "parent module" : {
2323
+ "name" : "INET-ADDRESS-MIB",
2324
+ "type" : "InetAddressType",
2325
+ },
2326
+ "unknown" : {
2327
+ "nodetype" : "namednumber",
2328
+ "number" : "0"
2329
+ },
2330
+ "ipv4" : {
2331
+ "nodetype" : "namednumber",
2332
+ "number" : "1"
2333
+ },
2334
+ "ipv6" : {
2335
+ "nodetype" : "namednumber",
2336
+ "number" : "2"
2337
+ },
2338
+ },
2339
+ }, # syntax
2340
+ "access" : "readonly",
2341
+ "description" :
2342
+ """Only unknown(0), ipv4(1), and ipv6(2) support
2343
+ is required.""",
2344
+ },
2345
+ "gmplsTunnelDownstreamNotifyRecipient" : {
2346
+ "module" : "GMPLS-TE-STD-MIB",
2347
+ "syntax" : {
2348
+ "type" : {
2349
+ "basetype" : "OctetString",
2350
+ "parent module" : {
2351
+ "name" : "INET-ADDRESS-MIB",
2352
+ "type" : "InetAddress",
2353
+ },
2354
+ "ranges" : [
2355
+ {
2356
+ "min" : "0",
2357
+ "max" : "0"
2358
+ },
2359
+ {
2360
+ "min" : "4",
2361
+ "max" : "4"
2362
+ },
2363
+ {
2364
+ "min" : "16",
2365
+ "max" : "16"
2366
+ },
2367
+ ],
2368
+ "range" : {
2369
+ "min" : "0",
2370
+ "max" : "16"
2371
+ },
2372
+ },
2373
+ }, # syntax
2374
+ "access" : "readonly",
2375
+ "description" :
2376
+ """An implementation is only required to support
2377
+ unknown(0), ipv4(1), and ipv6(2) sizes.""",
2378
+ },
2379
+ "gmplsTunnelSendPathNotifyRecipientType" : {
2380
+ "module" : "GMPLS-TE-STD-MIB",
2381
+ "syntax" : {
2382
+ "type" : {
2383
+ "basetype" : "Enumeration",
2384
+ "parent module" : {
2385
+ "name" : "INET-ADDRESS-MIB",
2386
+ "type" : "InetAddressType",
2387
+ },
2388
+ "unknown" : {
2389
+ "nodetype" : "namednumber",
2390
+ "number" : "0"
2391
+ },
2392
+ "ipv4" : {
2393
+ "nodetype" : "namednumber",
2394
+ "number" : "1"
2395
+ },
2396
+ "ipv6" : {
2397
+ "nodetype" : "namednumber",
2398
+ "number" : "2"
2399
+ },
2400
+ },
2401
+ }, # syntax
2402
+ "access" : "readonly",
2403
+ "description" :
2404
+ """Only unknown(0), ipv4(1), and ipv6(2) support
2405
+ is required.""",
2406
+ },
2407
+ "gmplsTunnelSendPathNotifyRecipient" : {
2408
+ "module" : "GMPLS-TE-STD-MIB",
2409
+ "syntax" : {
2410
+ "type" : {
2411
+ "basetype" : "OctetString",
2412
+ "parent module" : {
2413
+ "name" : "INET-ADDRESS-MIB",
2414
+ "type" : "InetAddress",
2415
+ },
2416
+ "ranges" : [
2417
+ {
2418
+ "min" : "0",
2419
+ "max" : "0"
2420
+ },
2421
+ {
2422
+ "min" : "4",
2423
+ "max" : "4"
2424
+ },
2425
+ {
2426
+ "min" : "16",
2427
+ "max" : "16"
2428
+ },
2429
+ ],
2430
+ "range" : {
2431
+ "min" : "0",
2432
+ "max" : "16"
2433
+ },
2434
+ },
2435
+ }, # syntax
2436
+ "access" : "readonly",
2437
+ "description" :
2438
+ """An implementation is only required to support
2439
+ unknown(0), ipv4(1), and ipv6(2) sizes.""",
2440
+ },
2441
+ "gmplsTunnelAdminStatusFlags" : {
2442
+ "module" : "GMPLS-TE-STD-MIB",
2443
+ "access" : "readonly",
2444
+ "description" :
2445
+ """Write access is not required.""",
2446
+ },
2447
+ "gmplsTunnelExtraParamsPtr" : {
2448
+ "module" : "GMPLS-TE-STD-MIB",
2449
+ "access" : "readonly",
2450
+ "description" :
2451
+ """Write access is not required.""",
2452
+ },
2453
+ "gmplsTunnelHopExplicitForwardLabel" : {
2454
+ "module" : "GMPLS-TE-STD-MIB",
2455
+ "access" : "readonly",
2456
+ "description" :
2457
+ """Write access is not required.""",
2458
+ },
2459
+ "gmplsTunnelHopExplicitForwardLabelPtr" : {
2460
+ "module" : "GMPLS-TE-STD-MIB",
2461
+ "access" : "readonly",
2462
+ "description" :
2463
+ """Write access is not required.""",
2464
+ },
2465
+ "gmplsTunnelHopExplicitReverseLabel" : {
2466
+ "module" : "GMPLS-TE-STD-MIB",
2467
+ "access" : "readonly",
2468
+ "description" :
2469
+ """Write access is not required.""",
2470
+ },
2471
+ "gmplsTunnelHopExplicitReverseLabelPtr" : {
2472
+ "module" : "GMPLS-TE-STD-MIB",
2473
+ "access" : "readonly",
2474
+ "description" :
2475
+ """Write access is not required.""",
2476
+ },
2477
+ "gmplsTunnelErrorReporterType" : {
2478
+ "module" : "GMPLS-TE-STD-MIB",
2479
+ "syntax" : {
2480
+ "type" : {
2481
+ "basetype" : "Enumeration",
2482
+ "parent module" : {
2483
+ "name" : "INET-ADDRESS-MIB",
2484
+ "type" : "InetAddressType",
2485
+ },
2486
+ "unknown" : {
2487
+ "nodetype" : "namednumber",
2488
+ "number" : "0"
2489
+ },
2490
+ "ipv4" : {
2491
+ "nodetype" : "namednumber",
2492
+ "number" : "1"
2493
+ },
2494
+ "ipv6" : {
2495
+ "nodetype" : "namednumber",
2496
+ "number" : "2"
2497
+ },
2498
+ },
2499
+ }, # syntax
2500
+ "description" :
2501
+ """Only unknown(0), ipv4(1), and ipv6(2) support
2502
+ is required.""",
2503
+ },
2504
+ "gmplsTunnelErrorReporter" : {
2505
+ "module" : "GMPLS-TE-STD-MIB",
2506
+ "syntax" : {
2507
+ "type" : {
2508
+ "basetype" : "OctetString",
2509
+ "parent module" : {
2510
+ "name" : "INET-ADDRESS-MIB",
2511
+ "type" : "InetAddress",
2512
+ },
2513
+ "ranges" : [
2514
+ {
2515
+ "min" : "0",
2516
+ "max" : "0"
2517
+ },
2518
+ {
2519
+ "min" : "4",
2520
+ "max" : "4"
2521
+ },
2522
+ {
2523
+ "min" : "16",
2524
+ "max" : "16"
2525
+ },
2526
+ ],
2527
+ "range" : {
2528
+ "min" : "0",
2529
+ "max" : "16"
2530
+ },
2531
+ },
2532
+ }, # syntax
2533
+ "description" :
2534
+ """An implementation is only required to support
2535
+ unknown(0), ipv4(1), and ipv6(2).""",
2536
+ },
2537
+ }, # refinements
2538
+
2539
+ }, # compliance
2540
+ }, # compliances
2541
+
2542
+ }