logstash-input-snmp 0.1.0.beta4 → 0.1.0.beta5

Sign up to get free protection for your applications and to get access to all the features.
Files changed (309) hide show
  1. checksums.yaml +4 -4
  2. data/CHANGELOG.md +5 -0
  3. data/lib/logstash/inputs/snmp.rb +75 -12
  4. data/lib/logstash/inputs/snmp/base_client.rb +162 -0
  5. data/lib/logstash/inputs/snmp/client.rb +11 -109
  6. data/lib/logstash/inputs/snmp/clientv3.rb +139 -0
  7. data/lib/logstash/inputs/snmp/mib.rb +22 -20
  8. data/lib/mibs/ietf/ACCOUNTING-CONTROL-MIB.dic +1316 -0
  9. data/lib/mibs/ietf/ADSL-LINE-EXT-MIB.dic +1724 -0
  10. data/lib/mibs/ietf/ADSL-LINE-MIB.dic +7297 -0
  11. data/lib/mibs/ietf/ADSL-TC-MIB.dic +160 -0
  12. data/lib/mibs/ietf/ADSL2-LINE-MIB.dic +8663 -0
  13. data/lib/mibs/ietf/ADSL2-LINE-TC-MIB.dic +1462 -0
  14. data/lib/mibs/ietf/AGENTX-MIB.dic +817 -0
  15. data/lib/mibs/ietf/AGGREGATE-MIB.dic +708 -0
  16. data/lib/mibs/ietf/ALARM-MIB.dic +1734 -0
  17. data/lib/mibs/ietf/APM-MIB.dic +2870 -0
  18. data/lib/mibs/ietf/APPC-MIB.dic +8687 -0
  19. data/lib/mibs/ietf/APPLETALK-MIB.dic +4399 -0
  20. data/lib/mibs/ietf/APPLICATION-MIB.dic +3750 -0
  21. data/lib/mibs/ietf/APPN-DLUR-MIB.dic +972 -0
  22. data/lib/mibs/ietf/APPN-MIB.dic +9364 -0
  23. data/lib/mibs/ietf/APPN-TRAP-MIB.dic +664 -0
  24. data/lib/mibs/ietf/APS-MIB.dic +2430 -0
  25. data/lib/mibs/ietf/ARC-MIB.dic +552 -0
  26. data/lib/mibs/ietf/ATM-ACCOUNTING-INFORMATION-MIB.dic +816 -0
  27. data/lib/mibs/ietf/ATM-MIB.dic +4104 -0
  28. data/lib/mibs/ietf/ATM-TC-MIB.dic +914 -0
  29. data/lib/mibs/ietf/ATM2-MIB.dic +4715 -0
  30. data/lib/mibs/ietf/BFD-STD-MIB.dic +2367 -0
  31. data/lib/mibs/ietf/BFD-TC-STD-MIB.dic +202 -0
  32. data/lib/mibs/ietf/BGP4-MIB.dic +1931 -0
  33. data/lib/mibs/ietf/BLDG-HVAC-MIB.dic +812 -0
  34. data/lib/mibs/ietf/BRIDGE-MIB.dic +2257 -0
  35. data/lib/mibs/ietf/CAPWAP-BASE-MIB.dic +4128 -0
  36. data/lib/mibs/ietf/CAPWAP-DOT11-MIB.dic +482 -0
  37. data/lib/mibs/ietf/CHARACTER-MIB.dic +1140 -0
  38. data/lib/mibs/ietf/CIRCUIT-IF-MIB.dic +493 -0
  39. data/lib/mibs/ietf/CLNS-MIB.dic +1702 -0
  40. data/lib/mibs/ietf/COFFEE-POT-MIB.dic +282 -0
  41. data/lib/mibs/ietf/COPS-CLIENT-MIB.dic +1270 -0
  42. data/lib/mibs/ietf/DECNET-PHIV-MIB.dic +5837 -0
  43. data/lib/mibs/ietf/DIAL-CONTROL-MIB.dic +2139 -0
  44. data/lib/mibs/ietf/DIFFSERV-CONFIG-MIB.dic +378 -0
  45. data/lib/mibs/ietf/DIFFSERV-MIB.dic +5073 -0
  46. data/lib/mibs/ietf/DIRECTORY-SERVER-MIB.dic +1041 -0
  47. data/lib/mibs/ietf/DISMAN-EVENT-MIB.dic +3151 -0
  48. data/lib/mibs/ietf/DISMAN-EXPRESSION-MIB.dic +1716 -0
  49. data/lib/mibs/ietf/DISMAN-NSLOOKUP-MIB.dic +698 -0
  50. data/lib/mibs/ietf/DISMAN-PING-MIB.dic +2635 -0
  51. data/lib/mibs/ietf/DISMAN-SCHEDULE-MIB.dic +1744 -0
  52. data/lib/mibs/ietf/DISMAN-SCRIPT-MIB.dic +2820 -0
  53. data/lib/mibs/ietf/DISMAN-TRACEROUTE-MIB.dic +3239 -0
  54. data/lib/mibs/ietf/DLSW-MIB.dic +5635 -0
  55. data/lib/mibs/ietf/DNS-RESOLVER-MIB.dic +1765 -0
  56. data/lib/mibs/ietf/DNS-SERVER-MIB.dic +1593 -0
  57. data/lib/mibs/ietf/DOCS-BPI-MIB.dic +2634 -0
  58. data/lib/mibs/ietf/DOCS-CABLE-DEVICE-MIB.dic +5042 -0
  59. data/lib/mibs/ietf/DOCS-IETF-BPI2-MIB.dic +5478 -0
  60. data/lib/mibs/ietf/DOCS-IETF-CABLE-DEVICE-NOTIFICATION-MIB.dic +2447 -0
  61. data/lib/mibs/ietf/DOCS-IETF-QOS-MIB.dic +4886 -0
  62. data/lib/mibs/ietf/DOCS-IETF-SUBMGT-MIB.dic +1331 -0
  63. data/lib/mibs/ietf/DOCS-IF-MIB.dic +7980 -0
  64. data/lib/mibs/ietf/DOT12-IF-MIB.dic +1066 -0
  65. data/lib/mibs/ietf/DOT12-RPTR-MIB.dic +2669 -0
  66. data/lib/mibs/ietf/DOT3-EPON-MIB.dic +3297 -0
  67. data/lib/mibs/ietf/DOT3-OAM-MIB.dic +2830 -0
  68. data/lib/mibs/ietf/DS0-MIB.dic +466 -0
  69. data/lib/mibs/ietf/DS0BUNDLE-MIB.dic +468 -0
  70. data/lib/mibs/ietf/DS1-MIB.dic +4890 -0
  71. data/lib/mibs/ietf/DS3-MIB.dic +2719 -0
  72. data/lib/mibs/ietf/DSA-MIB.dic +888 -0
  73. data/lib/mibs/ietf/DSMON-MIB.dic +6177 -0
  74. data/lib/mibs/ietf/DVB-RCS-MIB.dic +5764 -0
  75. data/lib/mibs/ietf/EBN-MIB.dic +1026 -0
  76. data/lib/mibs/ietf/EFM-CU-MIB.dic +4335 -0
  77. data/lib/mibs/ietf/ENTITY-MIB.dic +2235 -0
  78. data/lib/mibs/ietf/ENTITY-SENSOR-MIB.dic +653 -0
  79. data/lib/mibs/ietf/ENTITY-STATE-MIB.dic +457 -0
  80. data/lib/mibs/ietf/ENTITY-STATE-TC-MIB.dic +260 -0
  81. data/lib/mibs/ietf/ETHER-CHIPSET-MIB.dic +787 -0
  82. data/lib/mibs/ietf/EtherLike-MIB.dic +2548 -0
  83. data/lib/mibs/ietf/FC-MGMT-MIB.dic +3465 -0
  84. data/lib/mibs/ietf/FCIP-MGMT-MIB.dic +1596 -0
  85. data/lib/mibs/ietf/FDDI-SMT73-MIB.dic +3378 -0
  86. data/lib/mibs/ietf/FIBRE-CHANNEL-FE-MIB.dic +2504 -0
  87. data/lib/mibs/ietf/FLOAT-TC-MIB.dic +128 -0
  88. data/lib/mibs/ietf/FLOW-METER-MIB.dic +3201 -0
  89. data/lib/mibs/ietf/FORCES-MIB.dic +598 -0
  90. data/lib/mibs/ietf/FR-ATM-PVC-SERVICE-IWF-MIB.dic +1601 -0
  91. data/lib/mibs/ietf/FR-MFR-MIB.dic +1351 -0
  92. data/lib/mibs/ietf/FRAME-RELAY-DTE-MIB.dic +1688 -0
  93. data/lib/mibs/ietf/FRNETSERV-MIB.dic +3940 -0
  94. data/lib/mibs/ietf/FRSLD-MIB.dic +2580 -0
  95. data/lib/mibs/ietf/Finisher-MIB.dic +1416 -0
  96. data/lib/mibs/ietf/GMPLS-LABEL-STD-MIB.dic +965 -0
  97. data/lib/mibs/ietf/GMPLS-LSR-STD-MIB.dic +693 -0
  98. data/lib/mibs/ietf/GMPLS-TC-STD-MIB.dic +180 -0
  99. data/lib/mibs/ietf/GMPLS-TE-STD-MIB.dic +2542 -0
  100. data/lib/mibs/ietf/GSMP-MIB.dic +2468 -0
  101. data/lib/mibs/ietf/HC-ALARM-MIB.dic +1050 -0
  102. data/lib/mibs/ietf/HC-PerfHist-TC-MIB.dic +310 -0
  103. data/lib/mibs/ietf/HC-RMON-MIB.dic +4456 -0
  104. data/lib/mibs/ietf/HDSL2-SHDSL-LINE-MIB.dic +3955 -0
  105. data/lib/mibs/ietf/HOST-RESOURCES-MIB.dic +2453 -0
  106. data/lib/mibs/ietf/HPR-IP-MIB.dic +640 -0
  107. data/lib/mibs/ietf/HPR-MIB.dic +1959 -0
  108. data/lib/mibs/ietf/IANA-ITU-ALARM-TC-MIB.dic +936 -0
  109. data/lib/mibs/ietf/IF-CAP-STACK-MIB.dic +356 -0
  110. data/lib/mibs/ietf/IF-INVERTED-STACK-MIB.dic +220 -0
  111. data/lib/mibs/ietf/IF-MIB.dic +2753 -0
  112. data/lib/mibs/ietf/IFCP-MGMT-MIB.dic +1717 -0
  113. data/lib/mibs/ietf/IGMP-STD-MIB.dic +809 -0
  114. data/lib/mibs/ietf/INET-ADDRESS-MIB.dic +570 -0
  115. data/lib/mibs/ietf/INTEGRATED-SERVICES-GUARANTEED-MIB.dic +319 -0
  116. data/lib/mibs/ietf/INTEGRATED-SERVICES-MIB.dic +1196 -0
  117. data/lib/mibs/ietf/INTERFACETOPN-MIB.dic +1705 -0
  118. data/lib/mibs/ietf/IP-FORWARD-MIB.dic +1853 -0
  119. data/lib/mibs/ietf/IP-MIB.dic +7064 -0
  120. data/lib/mibs/ietf/IPATM-IPMC-MIB.dic +4830 -0
  121. data/lib/mibs/ietf/IPFIX-MIB.dic +2334 -0
  122. data/lib/mibs/ietf/IPFIX-SELECTOR-MIB.dic +215 -0
  123. data/lib/mibs/ietf/IPMCAST-MIB.dic +3390 -0
  124. data/lib/mibs/ietf/IPMROUTE-STD-MIB.dic +1246 -0
  125. data/lib/mibs/ietf/IPOA-MIB.dic +2372 -0
  126. data/lib/mibs/ietf/IPS-AUTH-MIB.dic +1609 -0
  127. data/lib/mibs/ietf/IPSEC-SPD-MIB.dic +3989 -0
  128. data/lib/mibs/ietf/IPV6-FLOW-LABEL-MIB.dic +110 -0
  129. data/lib/mibs/ietf/IPV6-ICMP-MIB.dic +748 -0
  130. data/lib/mibs/ietf/IPV6-MIB.dic +2028 -0
  131. data/lib/mibs/ietf/IPV6-MLD-MIB.dic +659 -0
  132. data/lib/mibs/ietf/IPV6-TCP-MIB.dic +332 -0
  133. data/lib/mibs/ietf/IPV6-UDP-MIB.dic +209 -0
  134. data/lib/mibs/ietf/ISCSI-MIB.dic +4613 -0
  135. data/lib/mibs/ietf/ISDN-MIB.dic +1796 -0
  136. data/lib/mibs/ietf/ISIS-MIB.dic +6215 -0
  137. data/lib/mibs/ietf/ISNS-MIB.dic +6578 -0
  138. data/lib/mibs/ietf/ITU-ALARM-MIB.dic +665 -0
  139. data/lib/mibs/ietf/ITU-ALARM-TC-MIB.dic +137 -0
  140. data/lib/mibs/ietf/Job-Monitoring-MIB.dic +2519 -0
  141. data/lib/mibs/ietf/L2TP-MIB.dic +4050 -0
  142. data/lib/mibs/ietf/LANGTAG-TC-MIB.dic +104 -0
  143. data/lib/mibs/ietf/LISP-MIB.dic +4067 -0
  144. data/lib/mibs/ietf/LMP-MIB.dic +5166 -0
  145. data/lib/mibs/ietf/MALLOC-MIB.dic +2156 -0
  146. data/lib/mibs/ietf/MAU-MIB.dic +2619 -0
  147. data/lib/mibs/ietf/MIDCOM-MIB.dic +2856 -0
  148. data/lib/mibs/ietf/MIOX25-MIB.dic +828 -0
  149. data/lib/mibs/ietf/MIP-MIB.dic +3473 -0
  150. data/lib/mibs/ietf/MOBILEIPV6-MIB.dic +5228 -0
  151. data/lib/mibs/ietf/MPLS-FTN-STD-MIB.dic +1594 -0
  152. data/lib/mibs/ietf/MPLS-L3VPN-STD-MIB.dic +2548 -0
  153. data/lib/mibs/ietf/MPLS-LC-ATM-STD-MIB.dic +491 -0
  154. data/lib/mibs/ietf/MPLS-LC-FR-STD-MIB.dic +395 -0
  155. data/lib/mibs/ietf/MPLS-LDP-ATM-STD-MIB.dic +1019 -0
  156. data/lib/mibs/ietf/MPLS-LDP-FRAME-RELAY-STD-MIB.dic +862 -0
  157. data/lib/mibs/ietf/MPLS-LDP-GENERIC-STD-MIB.dic +445 -0
  158. data/lib/mibs/ietf/MPLS-LDP-STD-MIB.dic +3657 -0
  159. data/lib/mibs/ietf/MPLS-LSR-STD-MIB.dic +3103 -0
  160. data/lib/mibs/ietf/MPLS-TC-STD-MIB.dic +911 -0
  161. data/lib/mibs/ietf/MPLS-TE-STD-MIB.dic +3673 -0
  162. data/lib/mibs/ietf/MSDP-MIB.dic +1893 -0
  163. data/lib/mibs/ietf/MTA-MIB.dic +1898 -0
  164. data/lib/mibs/ietf/Modem-MIB.dic +2054 -0
  165. data/lib/mibs/ietf/NAT-MIB.dic +3866 -0
  166. data/lib/mibs/ietf/NETWORK-SERVICES-MIB.dic +1034 -0
  167. data/lib/mibs/ietf/NHDP-MIB.dic +3005 -0
  168. data/lib/mibs/ietf/NHRP-MIB.dic +3660 -0
  169. data/lib/mibs/ietf/NOTIFICATION-LOG-MIB.dic +1156 -0
  170. data/lib/mibs/ietf/NTPv4-MIB.dic +1535 -0
  171. data/lib/mibs/ietf/OPT-IF-MIB.dic +8972 -0
  172. data/lib/mibs/ietf/OSPF-MIB.dic +5963 -0
  173. data/lib/mibs/ietf/OSPF-TRAP-MIB.dic +1190 -0
  174. data/lib/mibs/ietf/OSPFV3-MIB.dic +5708 -0
  175. data/lib/mibs/ietf/P-BRIDGE-MIB.dic +1499 -0
  176. data/lib/mibs/ietf/PARALLEL-MIB.dic +476 -0
  177. data/lib/mibs/ietf/PIM-MIB.dic +1393 -0
  178. data/lib/mibs/ietf/PIM-STD-MIB.dic +6819 -0
  179. data/lib/mibs/ietf/PINT-MIB.dic +830 -0
  180. data/lib/mibs/ietf/PKTC-IETF-MTA-MIB.dic +3191 -0
  181. data/lib/mibs/ietf/PKTC-IETF-SIG-MIB.dic +4713 -0
  182. data/lib/mibs/ietf/PMIPV6-MIB.dic +3010 -0
  183. data/lib/mibs/ietf/PMIPV6-TC-MIB.dic +293 -0
  184. data/lib/mibs/ietf/POLICY-BASED-MANAGEMENT-MIB.dic +3316 -0
  185. data/lib/mibs/ietf/POWER-ETHERNET-MIB.dic +959 -0
  186. data/lib/mibs/ietf/PPP-BRIDGE-NCP-MIB.dic +587 -0
  187. data/lib/mibs/ietf/PPP-IP-NCP-MIB.dic +269 -0
  188. data/lib/mibs/ietf/PPP-LCP-MIB.dic +994 -0
  189. data/lib/mibs/ietf/PPP-SEC-MIB.dic +411 -0
  190. data/lib/mibs/ietf/PSAMP-MIB.dic +998 -0
  191. data/lib/mibs/ietf/PTOPO-MIB.dic +1135 -0
  192. data/lib/mibs/ietf/PW-ATM-MIB.dic +1642 -0
  193. data/lib/mibs/ietf/PW-CEP-STD-MIB.dic +3661 -0
  194. data/lib/mibs/ietf/PW-STD-MIB.dic +3592 -0
  195. data/lib/mibs/ietf/PW-TC-STD-MIB.dic +437 -0
  196. data/lib/mibs/ietf/PW-TDM-MIB.dic +1896 -0
  197. data/lib/mibs/ietf/PerfHist-TC-MIB.dic +152 -0
  198. data/lib/mibs/ietf/Printer-MIB.dic +6665 -0
  199. data/lib/mibs/ietf/Q-BRIDGE-MIB.dic +3115 -0
  200. data/lib/mibs/ietf/RADIUS-ACC-CLIENT-MIB.dic +991 -0
  201. data/lib/mibs/ietf/RADIUS-ACC-SERVER-MIB.dic +1183 -0
  202. data/lib/mibs/ietf/RADIUS-AUTH-CLIENT-MIB.dic +1073 -0
  203. data/lib/mibs/ietf/RADIUS-AUTH-SERVER-MIB.dic +1251 -0
  204. data/lib/mibs/ietf/RADIUS-DYNAUTH-CLIENT-MIB.dic +1116 -0
  205. data/lib/mibs/ietf/RADIUS-DYNAUTH-SERVER-MIB.dic +1003 -0
  206. data/lib/mibs/ietf/RAQMON-MIB.dic +2695 -0
  207. data/lib/mibs/ietf/RBRIDGE-MIB.dic +2981 -0
  208. data/lib/mibs/ietf/RDBMS-MIB.dic +1935 -0
  209. data/lib/mibs/ietf/RFC1065-SMI.dic +108 -0
  210. data/lib/mibs/ietf/RFC1155-SMI.dic +118 -0
  211. data/lib/mibs/ietf/RFC1158-MIB.dic +2440 -0
  212. data/lib/mibs/ietf/RFC1213-MIB.dic +3434 -0
  213. data/lib/mibs/ietf/RFC1269-MIB.dic +557 -0
  214. data/lib/mibs/ietf/RFC1271-MIB.dic +4135 -0
  215. data/lib/mibs/ietf/RFC1285-MIB.dic +2842 -0
  216. data/lib/mibs/ietf/RFC1316-MIB.dic +800 -0
  217. data/lib/mibs/ietf/RFC1381-MIB.dic +1347 -0
  218. data/lib/mibs/ietf/RFC1382-MIB.dic +3820 -0
  219. data/lib/mibs/ietf/RFC1414-MIB.dic +214 -0
  220. data/lib/mibs/ietf/RIPv2-MIB.dic +773 -0
  221. data/lib/mibs/ietf/RMON-MIB.dic +5551 -0
  222. data/lib/mibs/ietf/RMON2-MIB.dic +8224 -0
  223. data/lib/mibs/ietf/ROHC-MIB.dic +1613 -0
  224. data/lib/mibs/ietf/ROHC-RTP-MIB.dic +859 -0
  225. data/lib/mibs/ietf/ROHC-UNCOMPRESSED-MIB.dic +267 -0
  226. data/lib/mibs/ietf/RPKI-ROUTER-MIB.dic +1363 -0
  227. data/lib/mibs/ietf/RS-232-MIB.dic +1335 -0
  228. data/lib/mibs/ietf/RSERPOOL-MIB.dic +2501 -0
  229. data/lib/mibs/ietf/RSTP-MIB.dic +427 -0
  230. data/lib/mibs/ietf/RSVP-MIB.dic +4135 -0
  231. data/lib/mibs/ietf/RTP-MIB.dic +1376 -0
  232. data/lib/mibs/ietf/SCSI-MIB.dic +3804 -0
  233. data/lib/mibs/ietf/SCTP-MIB.dic +1924 -0
  234. data/lib/mibs/ietf/SFLOW-MIB.dic +568 -0
  235. data/lib/mibs/ietf/SIP-COMMON-MIB.dic +2769 -0
  236. data/lib/mibs/ietf/SIP-MIB.dic +1438 -0
  237. data/lib/mibs/ietf/SIP-SERVER-MIB.dic +1150 -0
  238. data/lib/mibs/ietf/SIP-TC-MIB.dic +257 -0
  239. data/lib/mibs/ietf/SIP-UA-MIB.dic +268 -0
  240. data/lib/mibs/ietf/SLAPM-MIB.dic +4527 -0
  241. data/lib/mibs/ietf/SMON-MIB.dic +1758 -0
  242. data/lib/mibs/ietf/SNA-NAU-MIB.dic +4042 -0
  243. data/lib/mibs/ietf/SNA-SDLC-MIB.dic +3858 -0
  244. data/lib/mibs/ietf/SNMP-COMMUNITY-MIB.dic +715 -0
  245. data/lib/mibs/ietf/SNMP-FRAMEWORK-MIB.dic +709 -0
  246. data/lib/mibs/ietf/SNMP-MPD-MIB.dic +230 -0
  247. data/lib/mibs/ietf/SNMP-NOTIFICATION-MIB.dic +859 -0
  248. data/lib/mibs/ietf/SNMP-PROXY-MIB.dic +414 -0
  249. data/lib/mibs/ietf/SNMP-REPEATER-MIB.dic +4335 -0
  250. data/lib/mibs/ietf/SNMP-SSH-TM-MIB.dic +447 -0
  251. data/lib/mibs/ietf/SNMP-TARGET-MIB.dic +924 -0
  252. data/lib/mibs/ietf/SNMP-TLS-TM-MIB.dic +1449 -0
  253. data/lib/mibs/ietf/SNMP-TSM-MIB.dic +315 -0
  254. data/lib/mibs/ietf/SNMP-USER-BASED-SM-MIB.dic +1164 -0
  255. data/lib/mibs/ietf/SNMP-USM-AES-MIB.dic +95 -0
  256. data/lib/mibs/ietf/SNMP-USM-DH-OBJECTS-MIB.dic +653 -0
  257. data/lib/mibs/ietf/SNMP-VIEW-BASED-ACM-MIB.dic +1202 -0
  258. data/lib/mibs/ietf/SNMPv2-MIB.dic +1382 -0
  259. data/lib/mibs/ietf/SNMPv2-SMI.dic +223 -0
  260. data/lib/mibs/ietf/SNMPv2-USEC-MIB.dic +405 -0
  261. data/lib/mibs/ietf/SONET-MIB.dic +3308 -0
  262. data/lib/mibs/ietf/SOURCE-ROUTING-MIB.dic +542 -0
  263. data/lib/mibs/ietf/SSPM-MIB.dic +1530 -0
  264. data/lib/mibs/ietf/SYSAPPL-MIB.dic +2092 -0
  265. data/lib/mibs/ietf/T11-FC-FABRIC-ADDR-MGR-MIB.dic +1779 -0
  266. data/lib/mibs/ietf/T11-FC-FABRIC-CONFIG-SERVER-MIB.dic +2822 -0
  267. data/lib/mibs/ietf/T11-FC-FABRIC-LOCK-MIB.dic +700 -0
  268. data/lib/mibs/ietf/T11-FC-FSPF-MIB.dic +1889 -0
  269. data/lib/mibs/ietf/T11-FC-NAME-SERVER-MIB.dic +1775 -0
  270. data/lib/mibs/ietf/T11-FC-ROUTE-MIB.dic +655 -0
  271. data/lib/mibs/ietf/T11-FC-RSCN-MIB.dic +1110 -0
  272. data/lib/mibs/ietf/T11-FC-VIRTUAL-FABRIC-MIB.dic +770 -0
  273. data/lib/mibs/ietf/T11-FC-ZONE-SERVER-MIB.dic +3886 -0
  274. data/lib/mibs/ietf/T11-TC-MIB.dic +110 -0
  275. data/lib/mibs/ietf/TCP-ESTATS-MIB.dic +3926 -0
  276. data/lib/mibs/ietf/TCP-MIB.dic +1319 -0
  277. data/lib/mibs/ietf/TCPIPX-MIB.dic +457 -0
  278. data/lib/mibs/ietf/TE-LINK-STD-MIB.dic +2876 -0
  279. data/lib/mibs/ietf/TE-MIB.dic +2924 -0
  280. data/lib/mibs/ietf/TED-MIB.dic +1749 -0
  281. data/lib/mibs/ietf/TIME-AGGREGATE-MIB.dic +550 -0
  282. data/lib/mibs/ietf/TN3270E-MIB.dic +2785 -0
  283. data/lib/mibs/ietf/TN3270E-RT-MIB.dic +1317 -0
  284. data/lib/mibs/ietf/TOKEN-RING-RMON-MIB.dic +2820 -0
  285. data/lib/mibs/ietf/TOKENRING-MIB.dic +1184 -0
  286. data/lib/mibs/ietf/TOKENRING-STATION-SR-MIB.dic +292 -0
  287. data/lib/mibs/ietf/TRANSPORT-ADDRESS-MIB.dic +610 -0
  288. data/lib/mibs/ietf/TRIP-MIB.dic +3159 -0
  289. data/lib/mibs/ietf/TRIP-TC-MIB.dic +241 -0
  290. data/lib/mibs/ietf/TUNNEL-MIB.dic +1095 -0
  291. data/lib/mibs/ietf/UDP-MIB.dic +751 -0
  292. data/lib/mibs/ietf/UDPLITE-MIB.dic +704 -0
  293. data/lib/mibs/ietf/UPS-MIB.dic +3088 -0
  294. data/lib/mibs/ietf/URI-TC-MIB.dic +193 -0
  295. data/lib/mibs/ietf/UUID-TC-MIB.dic +135 -0
  296. data/lib/mibs/ietf/VDSL-LINE-EXT-MCM-MIB.dic +989 -0
  297. data/lib/mibs/ietf/VDSL-LINE-EXT-SCM-MIB.dic +605 -0
  298. data/lib/mibs/ietf/VDSL-LINE-MIB.dic +4518 -0
  299. data/lib/mibs/ietf/VDSL2-LINE-MIB.dic +11029 -0
  300. data/lib/mibs/ietf/VDSL2-LINE-TC-MIB.dic +3152 -0
  301. data/lib/mibs/ietf/VPN-TC-STD-MIB.dic +121 -0
  302. data/lib/mibs/ietf/VRRP-MIB.dic +1163 -0
  303. data/lib/mibs/ietf/VRRPV3-MIB.dic +1403 -0
  304. data/lib/mibs/ietf/WWW-MIB.dic +1810 -0
  305. data/lib/mibs/logstash/iso.dic +18 -0
  306. data/logstash-input-snmp.gemspec +1 -1
  307. data/spec/inputs/snmp/mib_spec.rb +10 -17
  308. data/spec/inputs/snmp_spec.rb +27 -1
  309. metadata +302 -2
@@ -0,0 +1,128 @@
1
+ # python version 1.0 DO NOT EDIT
2
+ #
3
+ # This python file has been generated by smidump version 0.5.0:
4
+ #
5
+ # smidump -f python FLOAT-TC-MIB
6
+
7
+ FILENAME = "./libsmi-0.5.0/mibs/ietf/FLOAT-TC-MIB"
8
+
9
+ MIB = {
10
+ "moduleName" : "FLOAT-TC-MIB",
11
+
12
+ "FLOAT-TC-MIB" : {
13
+ "nodetype" : "module",
14
+ "language" : "SMIv2",
15
+ "organization" :
16
+ """IETF OPSAWG Working Group""",
17
+ "contact" :
18
+ """WG Email: opsawg@ietf.org
19
+
20
+ Editor: Randy Presuhn
21
+ randy_presuhn@mindspring.com""",
22
+ "description" :
23
+ """Textual conventions for the representation
24
+ of floating-point numbers.
25
+
26
+ Copyright (c) 2011 IETF Trust and the persons
27
+ identified as authors of the code. All rights
28
+ reserved.
29
+
30
+ Redistribution and use in source and binary forms,
31
+ with or without modification, is permitted pursuant
32
+ to, and subject to the license terms contained in,
33
+ the Simplified BSD License set forth in Section
34
+ 4.c of the IETF Trust's Legal Provisions Relating
35
+ to IETF Documents
36
+ (http://trustee.ietf.org/license-info).
37
+
38
+ This version of this MIB module is part of RFC 6340;
39
+ see the RFC itself for full legal notices.""",
40
+ "revisions" : (
41
+ {
42
+ "date" : "2011-07-27 00:00",
43
+ "description" :
44
+ """Initial version, published as RFC 6340.""",
45
+ },
46
+ ),
47
+ "identity node" : "floatTcMIB",
48
+ },
49
+
50
+ "imports" : (
51
+ {"module" : "SNMPv2-SMI", "name" : "MODULE-IDENTITY"},
52
+ {"module" : "SNMPv2-SMI", "name" : "mib-2"},
53
+ {"module" : "SNMPv2-TC", "name" : "TEXTUAL-CONVENTION"},
54
+ ),
55
+
56
+ "typedefs" : {
57
+ "Float32TC" : {
58
+ "basetype" : "OctetString",
59
+ "status" : "current",
60
+ "ranges" : [
61
+ {
62
+ "min" : "4",
63
+ "max" : "4"
64
+ },
65
+ ],
66
+ "range" : {
67
+ "min" : "4",
68
+ "max" : "4"
69
+ },
70
+ "description" :
71
+ """This type represents a 32-bit (4-octet) IEEE
72
+ floating-point number in binary interchange format.""",
73
+ "reference" :
74
+ """IEEE Standard for Floating-Point Arithmetic,
75
+ Standard 754-2008""",
76
+ },
77
+ "Float64TC" : {
78
+ "basetype" : "OctetString",
79
+ "status" : "current",
80
+ "ranges" : [
81
+ {
82
+ "min" : "8",
83
+ "max" : "8"
84
+ },
85
+ ],
86
+ "range" : {
87
+ "min" : "8",
88
+ "max" : "8"
89
+ },
90
+ "description" :
91
+ """This type represents a 64-bit (8-octet) IEEE
92
+ floating-point number in binary interchange format.""",
93
+ "reference" :
94
+ """IEEE Standard for Floating-Point Arithmetic,
95
+ Standard 754-2008""",
96
+ },
97
+ "Float128TC" : {
98
+ "basetype" : "OctetString",
99
+ "status" : "current",
100
+ "ranges" : [
101
+ {
102
+ "min" : "16",
103
+ "max" : "16"
104
+ },
105
+ ],
106
+ "range" : {
107
+ "min" : "16",
108
+ "max" : "16"
109
+ },
110
+ "description" :
111
+ """This type represents a 128-bit (16-octet) IEEE
112
+ floating-point number in binary interchange format.""",
113
+ "reference" :
114
+ """IEEE Standard for Floating-Point Arithmetic,
115
+ Standard 754-2008""",
116
+ },
117
+ }, # typedefs
118
+
119
+ "nodes" : {
120
+ "floatTcMIB" : {
121
+ "nodetype" : "node",
122
+ "moduleName" : "FLOAT-TC-MIB",
123
+ "oid" : "1.3.6.1.2.1.201",
124
+ "status" : "current",
125
+ }, # node
126
+ }, # nodes
127
+
128
+ }
@@ -0,0 +1,3201 @@
1
+ # python version 1.0 DO NOT EDIT
2
+ #
3
+ # This python file has been generated by smidump version 0.5.0:
4
+ #
5
+ # smidump -f python FLOW-METER-MIB
6
+
7
+ FILENAME = "./libsmi-0.5.0/mibs/ietf/FLOW-METER-MIB"
8
+
9
+ MIB = {
10
+ "moduleName" : "FLOW-METER-MIB",
11
+
12
+ "FLOW-METER-MIB" : {
13
+ "nodetype" : "module",
14
+ "language" : "SMIv2",
15
+ "organization" :
16
+ """IETF Realtime Traffic Flow Measurement Working Group""",
17
+ "contact" :
18
+ """Nevil Brownlee, The University of Auckland
19
+
20
+ Postal: Information Technology Sytems & Services
21
+ The University of Auckland
22
+ Private Bag 92-019
23
+ Auckland, New Zealand
24
+
25
+ Phone: +64 9 373 7599 x8941
26
+ E-mail: n.brownlee@auckland.ac.nz""",
27
+ "description" :
28
+ """MIB for the RTFM Traffic Flow Meter.""",
29
+ "revisions" : (
30
+ {
31
+ "date" : "1999-10-25 00:00",
32
+ "description" :
33
+ """Initial Version, published as RFC 2720.""",
34
+ },
35
+ {
36
+ "date" : "1999-08-30 12:50",
37
+ "description" :
38
+ """UTF8OwnerString Textual Convention added, and used to
39
+ replace OwnerString. Conceptually the same as OwnerString,
40
+ but facilitating internationalisation by using UTF-8
41
+ encoding for its characters rather than US-ASCII.""",
42
+ },
43
+ {
44
+ "date" : "1999-08-19 10:10",
45
+ "description" :
46
+ """Changes to SIZE specification for two variables:
47
+ - flowRuleInfoName SIZE specified as (0..127)
48
+ - flowRuleIndex SIZE increased to (1..2147483647)""",
49
+ },
50
+ {
51
+ "date" : "1997-12-23 09:37",
52
+ "description" :
53
+ """Two further variables deprecated:
54
+ - flowRuleInfoRulesReady (use flowRuleInfoStatus intead)
55
+ - flowDataStatus (contains no useful information)""",
56
+ },
57
+ {
58
+ "date" : "1997-07-07 17:15",
59
+ "description" :
60
+ """Significant changes since RFC 2064 include:
61
+ - flowDataPackageTable added
62
+ - flowColumnActivityTable deprecated
63
+ - flowManagerCounterWrap deprecated""",
64
+ },
65
+ {
66
+ "date" : "1996-03-08 02:08",
67
+ "description" :
68
+ """Initial version of this MIB (RFC 2064)""",
69
+ },
70
+ ),
71
+ "identity node" : "flowMIB",
72
+ },
73
+
74
+ "imports" : (
75
+ {"module" : "SNMPv2-SMI", "name" : "MODULE-IDENTITY"},
76
+ {"module" : "SNMPv2-SMI", "name" : "OBJECT-TYPE"},
77
+ {"module" : "SNMPv2-SMI", "name" : "Counter32"},
78
+ {"module" : "SNMPv2-SMI", "name" : "Counter64"},
79
+ {"module" : "SNMPv2-SMI", "name" : "Integer32"},
80
+ {"module" : "SNMPv2-SMI", "name" : "mib-2"},
81
+ {"module" : "SNMPv2-TC", "name" : "TEXTUAL-CONVENTION"},
82
+ {"module" : "SNMPv2-TC", "name" : "RowStatus"},
83
+ {"module" : "SNMPv2-TC", "name" : "TimeStamp"},
84
+ {"module" : "SNMPv2-TC", "name" : "TruthValue"},
85
+ {"module" : "SNMPv2-CONF", "name" : "OBJECT-GROUP"},
86
+ {"module" : "SNMPv2-CONF", "name" : "MODULE-COMPLIANCE"},
87
+ {"module" : "IF-MIB", "name" : "ifIndex"},
88
+ {"module" : "RMON2-MIB", "name" : "TimeFilter"},
89
+ ),
90
+
91
+ "typedefs" : {
92
+ "UTF8OwnerString" : {
93
+ "basetype" : "OctetString",
94
+ "status" : "current",
95
+ "ranges" : [
96
+ {
97
+ "min" : "0",
98
+ "max" : "127"
99
+ },
100
+ ],
101
+ "range" : {
102
+ "min" : "0",
103
+ "max" : "127"
104
+ },
105
+ "format" : "127t",
106
+ "description" :
107
+ """An administratively assigned name for the owner of a
108
+ resource, conceptually the same as OwnerString in the RMON
109
+ MIB [RMON-MIB].
110
+
111
+ To facilitate internationalisation, this name information
112
+ is represented using the ISO/IEC IS 10646-1 character set,
113
+ encoded as an octet string using the UTF-8 transformation
114
+ format described in the UTF-8 standard [UTF-8].""",
115
+ },
116
+ "PeerType" : {
117
+ "basetype" : "Enumeration",
118
+ "status" : "current",
119
+ "ipv4" : {
120
+ "nodetype" : "namednumber",
121
+ "number" : "1"
122
+ },
123
+ "ipv6" : {
124
+ "nodetype" : "namednumber",
125
+ "number" : "2"
126
+ },
127
+ "nsap" : {
128
+ "nodetype" : "namednumber",
129
+ "number" : "3"
130
+ },
131
+ "ipx" : {
132
+ "nodetype" : "namednumber",
133
+ "number" : "11"
134
+ },
135
+ "appletalk" : {
136
+ "nodetype" : "namednumber",
137
+ "number" : "12"
138
+ },
139
+ "decnet" : {
140
+ "nodetype" : "namednumber",
141
+ "number" : "13"
142
+ },
143
+ "description" :
144
+ """Indicates the type of a PeerAddress (see below). The values
145
+ used are from the 'Address Family Numbers' section of the
146
+ Assigned Numbers RFC [ASG-NBR]. Peer types from other address
147
+ families may also be used, provided only that they are
148
+ identified by their assigned Address Family numbers.""",
149
+ },
150
+ "PeerAddress" : {
151
+ "basetype" : "OctetString",
152
+ "status" : "current",
153
+ "ranges" : [
154
+ {
155
+ "min" : "3",
156
+ "max" : "20"
157
+ },
158
+ ],
159
+ "range" : {
160
+ "min" : "3",
161
+ "max" : "20"
162
+ },
163
+ "description" :
164
+ """Specifies the value of a peer address for various network
165
+ protocols. Address format depends on the actual protocol,
166
+ as indicated below:
167
+
168
+ IPv4: ipv4(1)
169
+ 4-octet IpAddress (defined in the SNMPv2 SMI [RFC2578])
170
+
171
+ IPv6: ipv6(2)
172
+ 16-octet IpAddress (defined in the
173
+ IPv6 Addressing RFC [V6-ADDR])
174
+
175
+ CLNS: nsap(3)
176
+ NsapAddress (defined in the SNMPv2 SMI [RFC2578])
177
+
178
+ Novell: ipx(11)
179
+ 4-octet Network number,
180
+ 6-octet Host number (MAC address)
181
+
182
+ AppleTalk: appletalk(12)
183
+ 2-octet Network number (sixteen bits),
184
+ 1-octet Host number (eight bits)
185
+
186
+ DECnet: decnet(13)
187
+ 1-octet Area number (in low-order six bits),
188
+ 2-octet Host number (in low-order ten bits)""",
189
+ },
190
+ "AdjacentType" : {
191
+ "basetype" : "Enumeration",
192
+ "status" : "current",
193
+ "ip" : {
194
+ "nodetype" : "namednumber",
195
+ "number" : "1"
196
+ },
197
+ "nsap" : {
198
+ "nodetype" : "namednumber",
199
+ "number" : "3"
200
+ },
201
+ "ethernet" : {
202
+ "nodetype" : "namednumber",
203
+ "number" : "7"
204
+ },
205
+ "tokenring" : {
206
+ "nodetype" : "namednumber",
207
+ "number" : "9"
208
+ },
209
+ "ipx" : {
210
+ "nodetype" : "namednumber",
211
+ "number" : "11"
212
+ },
213
+ "appletalk" : {
214
+ "nodetype" : "namednumber",
215
+ "number" : "12"
216
+ },
217
+ "decnet" : {
218
+ "nodetype" : "namednumber",
219
+ "number" : "13"
220
+ },
221
+ "fddi" : {
222
+ "nodetype" : "namednumber",
223
+ "number" : "15"
224
+ },
225
+ "description" :
226
+ """Indicates the type of an adjacent address. May be a medium
227
+ type or (if metering is taking place inside a tunnel) a
228
+ PeerType (see above).
229
+
230
+ The values used for IEEE 802 medium types are from the 'Network
231
+ Management Parameters (ifType definitions)' section of the
232
+ Assigned Numbers RFC [ASG-NBR]. Other medium types may also
233
+ be used, provided only that they are identified by their
234
+ assigned ifType numbers.""",
235
+ },
236
+ "AdjacentAddress" : {
237
+ "basetype" : "OctetString",
238
+ "status" : "current",
239
+ "ranges" : [
240
+ {
241
+ "min" : "3",
242
+ "max" : "20"
243
+ },
244
+ ],
245
+ "range" : {
246
+ "min" : "3",
247
+ "max" : "20"
248
+ },
249
+ "description" :
250
+ """Specifies the value of an adjacent address. May be a Medium
251
+ Access Control (MAC) address or (if metering is taking place
252
+ inside a tunnel) a PeerAddress (see above).
253
+
254
+ MAC Address format depends on the actual medium, as follows:
255
+
256
+ Ethernet: ethernet(7)
257
+ 6-octet 802.3 MAC address in 'canonical' order
258
+ Token Ring: tokenring(9)
259
+ 6-octet 802.5 MAC address in 'canonical' order
260
+
261
+ FDDI: fddi(15)
262
+ FddiMACLongAddress, i.e. a 6-octet MAC address
263
+ in 'canonical' order (defined in [FDDI-MIB])""",
264
+ },
265
+ "TransportType" : {
266
+ "basetype" : "Integer32",
267
+ "status" : "current",
268
+ "ranges" : [
269
+ {
270
+ "min" : "1",
271
+ "max" : "255"
272
+ },
273
+ ],
274
+ "range" : {
275
+ "min" : "1",
276
+ "max" : "255"
277
+ },
278
+ "description" :
279
+ """Indicates the type of a TransportAddress (see below). Values
280
+ will depend on the actual protocol; for IP they will be those
281
+ given in the 'Protocol Numbers' section of the Assigned Numbers
282
+ RFC [ASG-NBR], including icmp(1), tcp(6) and udp(17).""",
283
+ },
284
+ "TransportAddress" : {
285
+ "basetype" : "OctetString",
286
+ "status" : "current",
287
+ "ranges" : [
288
+ {
289
+ "min" : "2",
290
+ "max" : "2"
291
+ },
292
+ ],
293
+ "range" : {
294
+ "min" : "2",
295
+ "max" : "2"
296
+ },
297
+ "description" :
298
+ """Specifies the value of a transport address for various
299
+ network protocols. Format as follows:
300
+
301
+ IP:
302
+ 2-octet UDP or TCP port number
303
+
304
+ Other protocols:
305
+ 2-octet port number""",
306
+ },
307
+ "RuleAddress" : {
308
+ "basetype" : "OctetString",
309
+ "status" : "current",
310
+ "ranges" : [
311
+ {
312
+ "min" : "2",
313
+ "max" : "20"
314
+ },
315
+ ],
316
+ "range" : {
317
+ "min" : "2",
318
+ "max" : "20"
319
+ },
320
+ "description" :
321
+ """Specifies the value of an address. Is a superset of
322
+ MediumAddress, PeerAddress and TransportAddress.""",
323
+ },
324
+ "FlowAttributeNumber" : {
325
+ "basetype" : "Enumeration",
326
+ "status" : "current",
327
+ "flowIndex" : {
328
+ "nodetype" : "namednumber",
329
+ "number" : "1"
330
+ },
331
+ "flowStatus" : {
332
+ "nodetype" : "namednumber",
333
+ "number" : "2"
334
+ },
335
+ "flowTimeMark" : {
336
+ "nodetype" : "namednumber",
337
+ "number" : "3"
338
+ },
339
+ "sourceInterface" : {
340
+ "nodetype" : "namednumber",
341
+ "number" : "4"
342
+ },
343
+ "sourceAdjacentType" : {
344
+ "nodetype" : "namednumber",
345
+ "number" : "5"
346
+ },
347
+ "sourceAdjacentAddress" : {
348
+ "nodetype" : "namednumber",
349
+ "number" : "6"
350
+ },
351
+ "sourceAdjacentMask" : {
352
+ "nodetype" : "namednumber",
353
+ "number" : "7"
354
+ },
355
+ "sourcePeerType" : {
356
+ "nodetype" : "namednumber",
357
+ "number" : "8"
358
+ },
359
+ "sourcePeerAddress" : {
360
+ "nodetype" : "namednumber",
361
+ "number" : "9"
362
+ },
363
+ "sourcePeerMask" : {
364
+ "nodetype" : "namednumber",
365
+ "number" : "10"
366
+ },
367
+ "sourceTransType" : {
368
+ "nodetype" : "namednumber",
369
+ "number" : "11"
370
+ },
371
+ "sourceTransAddress" : {
372
+ "nodetype" : "namednumber",
373
+ "number" : "12"
374
+ },
375
+ "sourceTransMask" : {
376
+ "nodetype" : "namednumber",
377
+ "number" : "13"
378
+ },
379
+ "destInterface" : {
380
+ "nodetype" : "namednumber",
381
+ "number" : "14"
382
+ },
383
+ "destAdjacentType" : {
384
+ "nodetype" : "namednumber",
385
+ "number" : "15"
386
+ },
387
+ "destAdjacentAddress" : {
388
+ "nodetype" : "namednumber",
389
+ "number" : "16"
390
+ },
391
+ "destAdjacentMask" : {
392
+ "nodetype" : "namednumber",
393
+ "number" : "17"
394
+ },
395
+ "destPeerType" : {
396
+ "nodetype" : "namednumber",
397
+ "number" : "18"
398
+ },
399
+ "destPeerAddress" : {
400
+ "nodetype" : "namednumber",
401
+ "number" : "19"
402
+ },
403
+ "destPeerMask" : {
404
+ "nodetype" : "namednumber",
405
+ "number" : "20"
406
+ },
407
+ "destTransType" : {
408
+ "nodetype" : "namednumber",
409
+ "number" : "21"
410
+ },
411
+ "destTransAddress" : {
412
+ "nodetype" : "namednumber",
413
+ "number" : "22"
414
+ },
415
+ "destTransMask" : {
416
+ "nodetype" : "namednumber",
417
+ "number" : "23"
418
+ },
419
+ "pduScale" : {
420
+ "nodetype" : "namednumber",
421
+ "number" : "24"
422
+ },
423
+ "octetScale" : {
424
+ "nodetype" : "namednumber",
425
+ "number" : "25"
426
+ },
427
+ "ruleSet" : {
428
+ "nodetype" : "namednumber",
429
+ "number" : "26"
430
+ },
431
+ "toOctets" : {
432
+ "nodetype" : "namednumber",
433
+ "number" : "27"
434
+ },
435
+ "toPDUs" : {
436
+ "nodetype" : "namednumber",
437
+ "number" : "28"
438
+ },
439
+ "fromOctets" : {
440
+ "nodetype" : "namednumber",
441
+ "number" : "29"
442
+ },
443
+ "fromPDUs" : {
444
+ "nodetype" : "namednumber",
445
+ "number" : "30"
446
+ },
447
+ "firstTime" : {
448
+ "nodetype" : "namednumber",
449
+ "number" : "31"
450
+ },
451
+ "lastActiveTime" : {
452
+ "nodetype" : "namednumber",
453
+ "number" : "32"
454
+ },
455
+ "sourceSubscriberID" : {
456
+ "nodetype" : "namednumber",
457
+ "number" : "33"
458
+ },
459
+ "destSubscriberID" : {
460
+ "nodetype" : "namednumber",
461
+ "number" : "34"
462
+ },
463
+ "sessionID" : {
464
+ "nodetype" : "namednumber",
465
+ "number" : "35"
466
+ },
467
+ "sourceClass" : {
468
+ "nodetype" : "namednumber",
469
+ "number" : "36"
470
+ },
471
+ "destClass" : {
472
+ "nodetype" : "namednumber",
473
+ "number" : "37"
474
+ },
475
+ "flowClass" : {
476
+ "nodetype" : "namednumber",
477
+ "number" : "38"
478
+ },
479
+ "sourceKind" : {
480
+ "nodetype" : "namednumber",
481
+ "number" : "39"
482
+ },
483
+ "destKind" : {
484
+ "nodetype" : "namednumber",
485
+ "number" : "40"
486
+ },
487
+ "flowKind" : {
488
+ "nodetype" : "namednumber",
489
+ "number" : "41"
490
+ },
491
+ "description" :
492
+ """Uniquely identifies an attribute within a flow data record.""",
493
+ },
494
+ "RuleAttributeNumber" : {
495
+ "basetype" : "Enumeration",
496
+ "status" : "current",
497
+ "null" : {
498
+ "nodetype" : "namednumber",
499
+ "number" : "0"
500
+ },
501
+ "sourceInterface" : {
502
+ "nodetype" : "namednumber",
503
+ "number" : "4"
504
+ },
505
+ "sourceAdjacentType" : {
506
+ "nodetype" : "namednumber",
507
+ "number" : "5"
508
+ },
509
+ "sourceAdjacentAddress" : {
510
+ "nodetype" : "namednumber",
511
+ "number" : "6"
512
+ },
513
+ "sourcePeerType" : {
514
+ "nodetype" : "namednumber",
515
+ "number" : "8"
516
+ },
517
+ "sourcePeerAddress" : {
518
+ "nodetype" : "namednumber",
519
+ "number" : "9"
520
+ },
521
+ "sourceTransType" : {
522
+ "nodetype" : "namednumber",
523
+ "number" : "11"
524
+ },
525
+ "sourceTransAddress" : {
526
+ "nodetype" : "namednumber",
527
+ "number" : "12"
528
+ },
529
+ "destInterface" : {
530
+ "nodetype" : "namednumber",
531
+ "number" : "14"
532
+ },
533
+ "destAdjacentType" : {
534
+ "nodetype" : "namednumber",
535
+ "number" : "15"
536
+ },
537
+ "destAdjacentAddress" : {
538
+ "nodetype" : "namednumber",
539
+ "number" : "16"
540
+ },
541
+ "destPeerType" : {
542
+ "nodetype" : "namednumber",
543
+ "number" : "18"
544
+ },
545
+ "destPeerAddress" : {
546
+ "nodetype" : "namednumber",
547
+ "number" : "19"
548
+ },
549
+ "destTransType" : {
550
+ "nodetype" : "namednumber",
551
+ "number" : "21"
552
+ },
553
+ "destTransAddress" : {
554
+ "nodetype" : "namednumber",
555
+ "number" : "22"
556
+ },
557
+ "sourceSubscriberID" : {
558
+ "nodetype" : "namednumber",
559
+ "number" : "33"
560
+ },
561
+ "destSubscriberID" : {
562
+ "nodetype" : "namednumber",
563
+ "number" : "34"
564
+ },
565
+ "sessionID" : {
566
+ "nodetype" : "namednumber",
567
+ "number" : "35"
568
+ },
569
+ "sourceClass" : {
570
+ "nodetype" : "namednumber",
571
+ "number" : "36"
572
+ },
573
+ "destClass" : {
574
+ "nodetype" : "namednumber",
575
+ "number" : "37"
576
+ },
577
+ "flowClass" : {
578
+ "nodetype" : "namednumber",
579
+ "number" : "38"
580
+ },
581
+ "sourceKind" : {
582
+ "nodetype" : "namednumber",
583
+ "number" : "39"
584
+ },
585
+ "destKind" : {
586
+ "nodetype" : "namednumber",
587
+ "number" : "40"
588
+ },
589
+ "flowKind" : {
590
+ "nodetype" : "namednumber",
591
+ "number" : "41"
592
+ },
593
+ "matchingStoD" : {
594
+ "nodetype" : "namednumber",
595
+ "number" : "50"
596
+ },
597
+ "v1" : {
598
+ "nodetype" : "namednumber",
599
+ "number" : "51"
600
+ },
601
+ "v2" : {
602
+ "nodetype" : "namednumber",
603
+ "number" : "52"
604
+ },
605
+ "v3" : {
606
+ "nodetype" : "namednumber",
607
+ "number" : "53"
608
+ },
609
+ "v4" : {
610
+ "nodetype" : "namednumber",
611
+ "number" : "54"
612
+ },
613
+ "v5" : {
614
+ "nodetype" : "namednumber",
615
+ "number" : "55"
616
+ },
617
+ "description" :
618
+ """Uniquely identifies an attribute which may be tested in
619
+ a rule. These include attributes whose values come directly
620
+ from (or are computed from) the flow's packets, and the five
621
+ 'meter' variables used to hold an Attribute Number.""",
622
+ },
623
+ "ActionNumber" : {
624
+ "basetype" : "Enumeration",
625
+ "status" : "current",
626
+ "ignore" : {
627
+ "nodetype" : "namednumber",
628
+ "number" : "1"
629
+ },
630
+ "noMatch" : {
631
+ "nodetype" : "namednumber",
632
+ "number" : "2"
633
+ },
634
+ "count" : {
635
+ "nodetype" : "namednumber",
636
+ "number" : "3"
637
+ },
638
+ "countPkt" : {
639
+ "nodetype" : "namednumber",
640
+ "number" : "4"
641
+ },
642
+ "return" : {
643
+ "nodetype" : "namednumber",
644
+ "number" : "5"
645
+ },
646
+ "gosub" : {
647
+ "nodetype" : "namednumber",
648
+ "number" : "6"
649
+ },
650
+ "gosubAct" : {
651
+ "nodetype" : "namednumber",
652
+ "number" : "7"
653
+ },
654
+ "assign" : {
655
+ "nodetype" : "namednumber",
656
+ "number" : "8"
657
+ },
658
+ "assignAct" : {
659
+ "nodetype" : "namednumber",
660
+ "number" : "9"
661
+ },
662
+ "goto" : {
663
+ "nodetype" : "namednumber",
664
+ "number" : "10"
665
+ },
666
+ "gotoAct" : {
667
+ "nodetype" : "namednumber",
668
+ "number" : "11"
669
+ },
670
+ "pushRuleTo" : {
671
+ "nodetype" : "namednumber",
672
+ "number" : "12"
673
+ },
674
+ "pushRuleToAct" : {
675
+ "nodetype" : "namednumber",
676
+ "number" : "13"
677
+ },
678
+ "pushPktTo" : {
679
+ "nodetype" : "namednumber",
680
+ "number" : "14"
681
+ },
682
+ "pushPktToAct" : {
683
+ "nodetype" : "namednumber",
684
+ "number" : "15"
685
+ },
686
+ "popTo" : {
687
+ "nodetype" : "namednumber",
688
+ "number" : "16"
689
+ },
690
+ "popToAct" : {
691
+ "nodetype" : "namednumber",
692
+ "number" : "17"
693
+ },
694
+ "description" :
695
+ """Uniquely identifies the action of a rule, i.e. the Pattern
696
+ Matching Engine's opcode number. Details of the opcodes
697
+ are given in the 'Traffic Flow Measurement: Architecture'
698
+ document [RTFM-ARC].""",
699
+ },
700
+ }, # typedefs
701
+
702
+ "nodes" : {
703
+ "flowMIB" : {
704
+ "nodetype" : "node",
705
+ "moduleName" : "FLOW-METER-MIB",
706
+ "oid" : "1.3.6.1.2.1.40",
707
+ "status" : "current",
708
+ }, # node
709
+ "flowControl" : {
710
+ "nodetype" : "node",
711
+ "moduleName" : "FLOW-METER-MIB",
712
+ "oid" : "1.3.6.1.2.1.40.1",
713
+ }, # node
714
+ "flowRuleSetInfoTable" : {
715
+ "nodetype" : "table",
716
+ "moduleName" : "FLOW-METER-MIB",
717
+ "oid" : "1.3.6.1.2.1.40.1.1",
718
+ "status" : "current",
719
+ "description" :
720
+ """An array of information about the RuleSets held in the
721
+ meter.
722
+
723
+ Any manager may configure a new RuleSet for the meter by
724
+ creating a row in this table with status active(1), and setting
725
+ values for all the objects in its rules. At this stage the new
726
+ RuleSet is available but not 'running', i.e. it is not being
727
+ used by the meter to produce entries in the flow table.
728
+
729
+ To actually 'run' a RuleSet a manager must create a row in
730
+ the flowManagerInfoTable, set it's flowManagerStatus to
731
+ active(1), and set either its CurrentRuleSet or StandbyRuleSet
732
+ to point to the RuleSet to be run.
733
+
734
+ Once a RuleSet is running a manager may not change any of the
735
+ objects within the RuleSet itself. Any attempt to do so should
736
+ result in a notWritable(17) SNMP error-status for such objects.
737
+
738
+ A manager may stop a RuleSet running by removing all
739
+ references to it in the flowManagerInfoTable (i.e. by setting
740
+ CurrentRuleSet and StandbyRuleSet values to 0). This provides
741
+ a way to stop RuleSets left running if a manager fails.
742
+ For example, when a manager is started, it could search the
743
+ meter's flowManager table and stop all RuleSets having a
744
+ specified value of flowRuleInfoOwner.
745
+
746
+ To prevent a manager from interfering with variables belonging
747
+ to another manager, the meter should use MIB views [RFC2575] so
748
+ as to limit each manager's access to the meter's variables,
749
+ effectively dividing the single meter into several virtual
750
+ meters, one for each independent manager.""",
751
+ }, # table
752
+ "flowRuleSetInfoEntry" : {
753
+ "nodetype" : "row",
754
+ "moduleName" : "FLOW-METER-MIB",
755
+ "oid" : "1.3.6.1.2.1.40.1.1.1",
756
+ "create" : "true",
757
+ "status" : "current",
758
+ "linkage" : [
759
+ "flowRuleInfoIndex",
760
+ ],
761
+ "description" :
762
+ """Information about a particular RuleSet.""",
763
+ }, # row
764
+ "flowRuleInfoIndex" : {
765
+ "nodetype" : "column",
766
+ "moduleName" : "FLOW-METER-MIB",
767
+ "oid" : "1.3.6.1.2.1.40.1.1.1.1",
768
+ "status" : "current",
769
+ "syntax" : {
770
+ "type" : {
771
+ "basetype" : "Integer32",
772
+ "ranges" : [
773
+ {
774
+ "min" : "1",
775
+ "max" : "2147483647"
776
+ },
777
+ ],
778
+ "range" : {
779
+ "min" : "1",
780
+ "max" : "2147483647"
781
+ },
782
+ },
783
+ },
784
+ "access" : "noaccess",
785
+ "description" :
786
+ """An index which selects an entry in the flowRuleSetInfoTable.
787
+ Each such entry contains control information for a particular
788
+ RuleSet which the meter may run.""",
789
+ }, # column
790
+ "flowRuleInfoSize" : {
791
+ "nodetype" : "column",
792
+ "moduleName" : "FLOW-METER-MIB",
793
+ "oid" : "1.3.6.1.2.1.40.1.1.1.2",
794
+ "status" : "current",
795
+ "syntax" : {
796
+ "type" : { "module" :"", "name" : "Integer32"},
797
+ },
798
+ "access" : "readwrite",
799
+ "description" :
800
+ """Number of rules in this RuleSet. Setting this variable will
801
+ cause the meter to allocate space for these rules.""",
802
+ }, # column
803
+ "flowRuleInfoOwner" : {
804
+ "nodetype" : "column",
805
+ "moduleName" : "FLOW-METER-MIB",
806
+ "oid" : "1.3.6.1.2.1.40.1.1.1.3",
807
+ "status" : "current",
808
+ "syntax" : {
809
+ "type" : { "module" :"FLOW-METER-MIB", "name" : "UTF8OwnerString"},
810
+ },
811
+ "access" : "readwrite",
812
+ "description" :
813
+ """Identifies the manager which 'owns' this RuleSet. A manager
814
+ must set this variable when creating a row in this table.""",
815
+ }, # column
816
+ "flowRuleInfoTimeStamp" : {
817
+ "nodetype" : "column",
818
+ "moduleName" : "FLOW-METER-MIB",
819
+ "oid" : "1.3.6.1.2.1.40.1.1.1.4",
820
+ "status" : "current",
821
+ "syntax" : {
822
+ "type" : { "module" :"SNMPv2-TC", "name" : "TimeStamp"},
823
+ },
824
+ "access" : "readonly",
825
+ "description" :
826
+ """Time this row's associated RuleSet was last changed.""",
827
+ }, # column
828
+ "flowRuleInfoStatus" : {
829
+ "nodetype" : "column",
830
+ "moduleName" : "FLOW-METER-MIB",
831
+ "oid" : "1.3.6.1.2.1.40.1.1.1.5",
832
+ "status" : "current",
833
+ "syntax" : {
834
+ "type" : { "module" :"SNMPv2-TC", "name" : "RowStatus"},
835
+ },
836
+ "access" : "readwrite",
837
+ "description" :
838
+ """The status of this flowRuleSetInfoEntry. If this value is
839
+ not active(1) the meter must not attempt to use the row's
840
+ associated RuleSet. Once its value has been set to active(1)
841
+ a manager may not change any of the other variables in the
842
+ row, nor the contents of the associated RuleSet. Any attempt
843
+ to do so should result in a notWritable(17) SNMP error-status
844
+ for such variables or objects.
845
+
846
+ To download a RuleSet, a manger could:
847
+ - Locate an open slot in the RuleSetInfoTable.
848
+ - Create a RuleSetInfoEntry by setting the status for this
849
+ open slot to createAndWait(5).
850
+ - Set flowRuleInfoSize and flowRuleInfoName as required.
851
+ - Download the rules into the row's rule table.
852
+ - Set flowRuleInfoStatus to active(1).
853
+
854
+ The RuleSet would then be ready to run. The manager is not
855
+ allowed to change the value of flowRuleInfoStatus from
856
+ active(1) if the associated RuleSet is being referenced by any
857
+ of the entries in the flowManagerInfoTable.
858
+
859
+ Setting RuleInfoStatus to destroy(6) destroys the associated
860
+ RuleSet together with any flow data collected by it.""",
861
+ }, # column
862
+ "flowRuleInfoName" : {
863
+ "nodetype" : "column",
864
+ "moduleName" : "FLOW-METER-MIB",
865
+ "oid" : "1.3.6.1.2.1.40.1.1.1.6",
866
+ "status" : "current",
867
+ "syntax" : {
868
+ "type" : {
869
+ "basetype" : "OctetString",
870
+ "ranges" : [
871
+ {
872
+ "min" : "0",
873
+ "max" : "127"
874
+ },
875
+ ],
876
+ "range" : {
877
+ "min" : "0",
878
+ "max" : "127"
879
+ },
880
+ },
881
+ },
882
+ "access" : "readwrite",
883
+ "description" :
884
+ """An alphanumeric identifier used by managers and readers to
885
+ identify a RuleSet. For example, a manager wishing to run a
886
+ RuleSet named WWW-FLOWS could search the flowRuleSetInfoTable
887
+ to see whether the WWW-FLOWS RuleSet is already available on
888
+ the meter.
889
+
890
+ Note that references to RuleSets in the flowManagerInfoTable
891
+ use indexes for their flowRuleSetInfoTable entries. These may
892
+ be different each time the RuleSet is loaded into a meter.""",
893
+ }, # column
894
+ "flowRuleInfoRulesReady" : {
895
+ "nodetype" : "column",
896
+ "moduleName" : "FLOW-METER-MIB",
897
+ "oid" : "1.3.6.1.2.1.40.1.1.1.7",
898
+ "status" : "deprecated",
899
+ "syntax" : {
900
+ "type" : { "module" :"SNMPv2-TC", "name" : "TruthValue"},
901
+ },
902
+ "access" : "readwrite",
903
+ "description" :
904
+ """Indicates whether the rules for this row's associated RuleSet
905
+ are ready for use. The meter will refuse to 'run' the RuleSet
906
+ unless this variable has been set to true(1).
907
+ While RulesReady is false(2), the manager may modify the
908
+ RuleSet, for example by downloading rules into it.""",
909
+ }, # column
910
+ "flowRuleInfoFlowRecords" : {
911
+ "nodetype" : "column",
912
+ "moduleName" : "FLOW-METER-MIB",
913
+ "oid" : "1.3.6.1.2.1.40.1.1.1.8",
914
+ "status" : "current",
915
+ "syntax" : {
916
+ "type" : { "module" :"", "name" : "Integer32"},
917
+ },
918
+ "access" : "readonly",
919
+ "description" :
920
+ """The number of entries in the flow table for this RuleSet.
921
+ These may be current (waiting for collection by one or more
922
+ meter readers) or idle (waiting for the meter to recover
923
+ their memory).""",
924
+ }, # column
925
+ "flowInterfaceTable" : {
926
+ "nodetype" : "table",
927
+ "moduleName" : "FLOW-METER-MIB",
928
+ "oid" : "1.3.6.1.2.1.40.1.2",
929
+ "status" : "current",
930
+ "description" :
931
+ """An array of information specific to each meter interface.""",
932
+ }, # table
933
+ "flowInterfaceEntry" : {
934
+ "nodetype" : "row",
935
+ "moduleName" : "FLOW-METER-MIB",
936
+ "oid" : "1.3.6.1.2.1.40.1.2.1",
937
+ "status" : "current",
938
+ "linkage" : [
939
+ "ifIndex",
940
+ ],
941
+ "description" :
942
+ """Information about a particular interface.""",
943
+ }, # row
944
+ "flowInterfaceSampleRate" : {
945
+ "nodetype" : "column",
946
+ "moduleName" : "FLOW-METER-MIB",
947
+ "oid" : "1.3.6.1.2.1.40.1.2.1.1",
948
+ "status" : "current",
949
+ "syntax" : {
950
+ "type" : { "module" :"", "name" : "Integer32"},
951
+ },
952
+ "access" : "readwrite",
953
+ "default" : "1",
954
+ "description" :
955
+ """The parameter N for statistical counting on this interface.
956
+ Set to N to count 1/Nth of the packets appearing at this
957
+ interface. A sampling rate of 1 counts all packets.
958
+ A sampling rate of 0 results in the interface being ignored
959
+ by the meter.
960
+
961
+ A meter should choose its own algorithm to introduce variance
962
+ into the sampling so that exactly every Nth packet is counted.
963
+ The IPPM Working Group's RFC 'Framework for IP Performance
964
+ Metrics' [IPPM-FRM] explains why this should be done, and sets
965
+ out an algorithm for doing it.""",
966
+ }, # column
967
+ "flowInterfaceLostPackets" : {
968
+ "nodetype" : "column",
969
+ "moduleName" : "FLOW-METER-MIB",
970
+ "oid" : "1.3.6.1.2.1.40.1.2.1.2",
971
+ "status" : "current",
972
+ "syntax" : {
973
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
974
+ },
975
+ "access" : "readonly",
976
+ "description" :
977
+ """The number of packets the meter has lost for this interface.
978
+ Such losses may occur because the meter has been unable to
979
+ keep up with the traffic volume.""",
980
+ }, # column
981
+ "flowReaderInfoTable" : {
982
+ "nodetype" : "table",
983
+ "moduleName" : "FLOW-METER-MIB",
984
+ "oid" : "1.3.6.1.2.1.40.1.3",
985
+ "status" : "current",
986
+ "description" :
987
+ """An array of information about meter readers which have
988
+ registered their intent to collect flow data from this meter.""",
989
+ }, # table
990
+ "flowReaderInfoEntry" : {
991
+ "nodetype" : "row",
992
+ "moduleName" : "FLOW-METER-MIB",
993
+ "oid" : "1.3.6.1.2.1.40.1.3.1",
994
+ "create" : "true",
995
+ "status" : "current",
996
+ "linkage" : [
997
+ "flowReaderIndex",
998
+ ],
999
+ "description" :
1000
+ """Information about a particular meter reader.""",
1001
+ }, # row
1002
+ "flowReaderIndex" : {
1003
+ "nodetype" : "column",
1004
+ "moduleName" : "FLOW-METER-MIB",
1005
+ "oid" : "1.3.6.1.2.1.40.1.3.1.1",
1006
+ "status" : "current",
1007
+ "syntax" : {
1008
+ "type" : {
1009
+ "basetype" : "Integer32",
1010
+ "ranges" : [
1011
+ {
1012
+ "min" : "1",
1013
+ "max" : "2147483647"
1014
+ },
1015
+ ],
1016
+ "range" : {
1017
+ "min" : "1",
1018
+ "max" : "2147483647"
1019
+ },
1020
+ },
1021
+ },
1022
+ "access" : "noaccess",
1023
+ "description" :
1024
+ """An index which selects an entry in the flowReaderInfoTable.""",
1025
+ }, # column
1026
+ "flowReaderTimeout" : {
1027
+ "nodetype" : "column",
1028
+ "moduleName" : "FLOW-METER-MIB",
1029
+ "oid" : "1.3.6.1.2.1.40.1.3.1.2",
1030
+ "status" : "current",
1031
+ "syntax" : {
1032
+ "type" : { "module" :"", "name" : "Integer32"},
1033
+ },
1034
+ "access" : "readwrite",
1035
+ "description" :
1036
+ """Specifies the maximum time (in seconds) between flow data
1037
+ collections for this meter reader. If this time elapses
1038
+ without a collection, the meter should assume that this meter
1039
+ reader has stopped collecting, and delete this row from the
1040
+ table. A value of zero indicates that this row should not be
1041
+ timed out.""",
1042
+ }, # column
1043
+ "flowReaderOwner" : {
1044
+ "nodetype" : "column",
1045
+ "moduleName" : "FLOW-METER-MIB",
1046
+ "oid" : "1.3.6.1.2.1.40.1.3.1.3",
1047
+ "status" : "current",
1048
+ "syntax" : {
1049
+ "type" : { "module" :"FLOW-METER-MIB", "name" : "UTF8OwnerString"},
1050
+ },
1051
+ "access" : "readwrite",
1052
+ "description" :
1053
+ """Identifies the meter reader which created this row.""",
1054
+ }, # column
1055
+ "flowReaderLastTime" : {
1056
+ "nodetype" : "column",
1057
+ "moduleName" : "FLOW-METER-MIB",
1058
+ "oid" : "1.3.6.1.2.1.40.1.3.1.4",
1059
+ "status" : "current",
1060
+ "syntax" : {
1061
+ "type" : { "module" :"SNMPv2-TC", "name" : "TimeStamp"},
1062
+ },
1063
+ "access" : "readwrite",
1064
+ "description" :
1065
+ """Time this meter reader began its most recent data collection.
1066
+
1067
+ This variable should be written by a meter reader as its first
1068
+ step in reading flow data. The meter will set this LastTime
1069
+ value to its current Uptime, and set its PreviousTime value
1070
+ (below) to the old LastTime. This allows the meter to
1071
+ recover flows which have been inactive since PreviousTime,
1072
+ for these have been collected at least once.
1073
+
1074
+ If the meter reader fails to write flowLastReadTime, collection
1075
+ may still proceed but the meter may not be able to recover
1076
+ inactive flows until the flowReaderTimeout has been reached
1077
+ for this entry.""",
1078
+ }, # column
1079
+ "flowReaderPreviousTime" : {
1080
+ "nodetype" : "column",
1081
+ "moduleName" : "FLOW-METER-MIB",
1082
+ "oid" : "1.3.6.1.2.1.40.1.3.1.5",
1083
+ "status" : "current",
1084
+ "syntax" : {
1085
+ "type" : { "module" :"SNMPv2-TC", "name" : "TimeStamp"},
1086
+ },
1087
+ "access" : "readonly",
1088
+ "description" :
1089
+ """Time this meter reader began the collection before last.""",
1090
+ }, # column
1091
+ "flowReaderStatus" : {
1092
+ "nodetype" : "column",
1093
+ "moduleName" : "FLOW-METER-MIB",
1094
+ "oid" : "1.3.6.1.2.1.40.1.3.1.6",
1095
+ "status" : "current",
1096
+ "syntax" : {
1097
+ "type" : { "module" :"SNMPv2-TC", "name" : "RowStatus"},
1098
+ },
1099
+ "access" : "readwrite",
1100
+ "description" :
1101
+ """The status of this FlowReaderInfoEntry. A value of active(1)
1102
+ implies that the associated reader should be collecting data
1103
+ from the meter. Once this variable has been set to active(1)
1104
+ a manager may only change this row's flowReaderLastTime and
1105
+ flowReaderTimeout variables.""",
1106
+ }, # column
1107
+ "flowReaderRuleSet" : {
1108
+ "nodetype" : "column",
1109
+ "moduleName" : "FLOW-METER-MIB",
1110
+ "oid" : "1.3.6.1.2.1.40.1.3.1.7",
1111
+ "status" : "current",
1112
+ "syntax" : {
1113
+ "type" : {
1114
+ "basetype" : "Integer32",
1115
+ "ranges" : [
1116
+ {
1117
+ "min" : "1",
1118
+ "max" : "2147483647"
1119
+ },
1120
+ ],
1121
+ "range" : {
1122
+ "min" : "1",
1123
+ "max" : "2147483647"
1124
+ },
1125
+ },
1126
+ },
1127
+ "access" : "readwrite",
1128
+ "description" :
1129
+ """An index to the array of RuleSets. Specifies a set of rules
1130
+ of interest to this meter reader. The reader will attempt to
1131
+ collect any data generated by the meter for this RuleSet, and
1132
+ the meter will not recover the memory of any of the RuleSet's
1133
+ flows until this collection has taken place. Note that a
1134
+ reader may have entries in this table for several RuleSets.""",
1135
+ }, # column
1136
+ "flowManagerInfoTable" : {
1137
+ "nodetype" : "table",
1138
+ "moduleName" : "FLOW-METER-MIB",
1139
+ "oid" : "1.3.6.1.2.1.40.1.4",
1140
+ "status" : "current",
1141
+ "description" :
1142
+ """An array of information about managers which have
1143
+ registered their intent to run RuleSets on this meter.""",
1144
+ }, # table
1145
+ "flowManagerInfoEntry" : {
1146
+ "nodetype" : "row",
1147
+ "moduleName" : "FLOW-METER-MIB",
1148
+ "oid" : "1.3.6.1.2.1.40.1.4.1",
1149
+ "create" : "true",
1150
+ "status" : "current",
1151
+ "linkage" : [
1152
+ "flowManagerIndex",
1153
+ ],
1154
+ "description" :
1155
+ """Information about a particular meter 'task.' By creating
1156
+ an entry in this table and activating it, a manager requests
1157
+ that the meter 'run' the indicated RuleSet.
1158
+
1159
+ The entry also specifies a HighWaterMark and a StandbyRuleSet.
1160
+ If the meter's flow table usage exceeds this task's
1161
+ HighWaterMark the meter will stop running the task's
1162
+ CurrentRuleSet and switch to its StandbyRuleSet.
1163
+
1164
+ If the value of the task's StandbyRuleSet is 0 when its
1165
+ HighWaterMark is exceeded, the meter simply stops running the
1166
+ task's CurrentRuleSet. By careful selection of HighWaterMarks
1167
+ for the various tasks a manager can ensure that the most
1168
+ critical RuleSets are the last to stop running as the number
1169
+ of flows increases.
1170
+
1171
+ When a manager has determined that the demand for flow table
1172
+ space has abated, it may cause the task to switch back to its
1173
+ CurrentRuleSet by setting its flowManagerRunningStandby
1174
+ variable to false(2).""",
1175
+ }, # row
1176
+ "flowManagerIndex" : {
1177
+ "nodetype" : "column",
1178
+ "moduleName" : "FLOW-METER-MIB",
1179
+ "oid" : "1.3.6.1.2.1.40.1.4.1.1",
1180
+ "status" : "current",
1181
+ "syntax" : {
1182
+ "type" : {
1183
+ "basetype" : "Integer32",
1184
+ "ranges" : [
1185
+ {
1186
+ "min" : "1",
1187
+ "max" : "2147483647"
1188
+ },
1189
+ ],
1190
+ "range" : {
1191
+ "min" : "1",
1192
+ "max" : "2147483647"
1193
+ },
1194
+ },
1195
+ },
1196
+ "access" : "noaccess",
1197
+ "description" :
1198
+ """An index which selects an entry in the flowManagerInfoTable.""",
1199
+ }, # column
1200
+ "flowManagerCurrentRuleSet" : {
1201
+ "nodetype" : "column",
1202
+ "moduleName" : "FLOW-METER-MIB",
1203
+ "oid" : "1.3.6.1.2.1.40.1.4.1.2",
1204
+ "status" : "current",
1205
+ "syntax" : {
1206
+ "type" : { "module" :"", "name" : "Integer32"},
1207
+ },
1208
+ "access" : "readwrite",
1209
+ "description" :
1210
+ """Index to the array of RuleSets. Specifies which set of
1211
+ rules is the 'current' one for this task. The meter will
1212
+ be 'running' the current RuleSet if this row's
1213
+ flowManagerRunningStandby value is false(2).
1214
+
1215
+ When the manager sets this variable the meter will stop using
1216
+ the task's old current RuleSet and start using the new one.
1217
+ Specifying RuleSet 0 (the empty set) stops flow measurement
1218
+ for this task.""",
1219
+ }, # column
1220
+ "flowManagerStandbyRuleSet" : {
1221
+ "nodetype" : "column",
1222
+ "moduleName" : "FLOW-METER-MIB",
1223
+ "oid" : "1.3.6.1.2.1.40.1.4.1.3",
1224
+ "status" : "current",
1225
+ "syntax" : {
1226
+ "type" : { "module" :"", "name" : "Integer32"},
1227
+ },
1228
+ "access" : "readwrite",
1229
+ "default" : "0",
1230
+ "description" :
1231
+ """Index to the array of RuleSets. After reaching HighWaterMark
1232
+ (see below) the manager will switch to using the task's
1233
+ StandbyRuleSet in place of its CurrentRuleSet. For this to be
1234
+ effective the designated StandbyRuleSet should have a coarser
1235
+ reporting granularity then the CurrentRuleSet. The manager may
1236
+ also need to decrease the meter reading interval so that the
1237
+ meter can recover flows measured by this task's CurrentRuleSet.""",
1238
+ }, # column
1239
+ "flowManagerHighWaterMark" : {
1240
+ "nodetype" : "column",
1241
+ "moduleName" : "FLOW-METER-MIB",
1242
+ "oid" : "1.3.6.1.2.1.40.1.4.1.4",
1243
+ "status" : "current",
1244
+ "syntax" : {
1245
+ "type" : {
1246
+ "basetype" : "Integer32",
1247
+ "ranges" : [
1248
+ {
1249
+ "min" : "0",
1250
+ "max" : "100"
1251
+ },
1252
+ ],
1253
+ "range" : {
1254
+ "min" : "0",
1255
+ "max" : "100"
1256
+ },
1257
+ },
1258
+ },
1259
+ "access" : "readwrite",
1260
+ "description" :
1261
+ """A value expressed as a percentage, interpreted by the meter
1262
+ as an indication of how full the flow table should be before
1263
+ it should switch to the standby RuleSet (if one has been
1264
+ specified) for this task. Values of 0% or 100% disable the
1265
+ checking represented by this variable.""",
1266
+ }, # column
1267
+ "flowManagerCounterWrap" : {
1268
+ "nodetype" : "column",
1269
+ "moduleName" : "FLOW-METER-MIB",
1270
+ "oid" : "1.3.6.1.2.1.40.1.4.1.5",
1271
+ "status" : "deprecated",
1272
+ "syntax" : {
1273
+ "type" : {
1274
+ "basetype" : "Enumeration",
1275
+ "wrap" : {
1276
+ "nodetype" : "namednumber",
1277
+ "number" : "1"
1278
+ },
1279
+ "scale" : {
1280
+ "nodetype" : "namednumber",
1281
+ "number" : "2"
1282
+ },
1283
+ },
1284
+ },
1285
+ "access" : "readwrite",
1286
+ "default" : "wrap",
1287
+ "description" :
1288
+ """Specifies whether PDU and octet counters should wrap when
1289
+ they reach the top of their range (normal behaviour for
1290
+ Counter64 objects), or whether their scale factors should
1291
+ be used instead. The combination of counter and scale
1292
+ factor allows counts to be returned as non-negative binary
1293
+ floating point numbers, with 64-bit mantissas and 8-bit
1294
+ exponents.""",
1295
+ }, # column
1296
+ "flowManagerOwner" : {
1297
+ "nodetype" : "column",
1298
+ "moduleName" : "FLOW-METER-MIB",
1299
+ "oid" : "1.3.6.1.2.1.40.1.4.1.6",
1300
+ "status" : "current",
1301
+ "syntax" : {
1302
+ "type" : { "module" :"FLOW-METER-MIB", "name" : "UTF8OwnerString"},
1303
+ },
1304
+ "access" : "readwrite",
1305
+ "description" :
1306
+ """Identifies the manager which created this row.""",
1307
+ }, # column
1308
+ "flowManagerTimeStamp" : {
1309
+ "nodetype" : "column",
1310
+ "moduleName" : "FLOW-METER-MIB",
1311
+ "oid" : "1.3.6.1.2.1.40.1.4.1.7",
1312
+ "status" : "current",
1313
+ "syntax" : {
1314
+ "type" : { "module" :"SNMPv2-TC", "name" : "TimeStamp"},
1315
+ },
1316
+ "access" : "readonly",
1317
+ "description" :
1318
+ """Time this row was last changed by its manager.""",
1319
+ }, # column
1320
+ "flowManagerStatus" : {
1321
+ "nodetype" : "column",
1322
+ "moduleName" : "FLOW-METER-MIB",
1323
+ "oid" : "1.3.6.1.2.1.40.1.4.1.8",
1324
+ "status" : "current",
1325
+ "syntax" : {
1326
+ "type" : { "module" :"SNMPv2-TC", "name" : "RowStatus"},
1327
+ },
1328
+ "access" : "readwrite",
1329
+ "description" :
1330
+ """The status of this row in the flowManagerInfoTable. A value
1331
+ of active(1) implies that this task may be activated, by
1332
+ setting its CurrentRuleSet and StandbyRuleSet variables.
1333
+ Its HighWaterMark and RunningStandby variables may also be
1334
+ changed.""",
1335
+ }, # column
1336
+ "flowManagerRunningStandby" : {
1337
+ "nodetype" : "column",
1338
+ "moduleName" : "FLOW-METER-MIB",
1339
+ "oid" : "1.3.6.1.2.1.40.1.4.1.9",
1340
+ "status" : "current",
1341
+ "syntax" : {
1342
+ "type" : { "module" :"SNMPv2-TC", "name" : "TruthValue"},
1343
+ },
1344
+ "access" : "readwrite",
1345
+ "default" : "false",
1346
+ "description" :
1347
+ """Set to true(1) by the meter to indicate that it has switched
1348
+ to runnning this task's StandbyRuleSet in place of its
1349
+ CurrentRuleSet. To switch back to the CurrentRuleSet, the
1350
+ manager may simply set this variable to false(2).""",
1351
+ }, # column
1352
+ "flowFloodMark" : {
1353
+ "nodetype" : "scalar",
1354
+ "moduleName" : "FLOW-METER-MIB",
1355
+ "oid" : "1.3.6.1.2.1.40.1.5",
1356
+ "status" : "current",
1357
+ "syntax" : {
1358
+ "type" : {
1359
+ "basetype" : "Integer32",
1360
+ "ranges" : [
1361
+ {
1362
+ "min" : "0",
1363
+ "max" : "100"
1364
+ },
1365
+ ],
1366
+ "range" : {
1367
+ "min" : "0",
1368
+ "max" : "100"
1369
+ },
1370
+ },
1371
+ },
1372
+ "access" : "readwrite",
1373
+ "default" : "95",
1374
+ "description" :
1375
+ """A value expressed as a percentage, interpreted by the meter
1376
+ as an indication of how full the flow table should be before
1377
+ it should take some action to avoid running out of resources
1378
+ to handle new flows, as discussed in section 4.6 (Handling
1379
+ Increasing Traffic Levels) of the RTFM Architecture RFC
1380
+ [RTFM-ARC].
1381
+
1382
+ Values of 0% or 100% disable the checking represented by
1383
+ this variable.""",
1384
+ }, # scalar
1385
+ "flowInactivityTimeout" : {
1386
+ "nodetype" : "scalar",
1387
+ "moduleName" : "FLOW-METER-MIB",
1388
+ "oid" : "1.3.6.1.2.1.40.1.6",
1389
+ "status" : "current",
1390
+ "syntax" : {
1391
+ "type" : { "module" :"", "name" : "Integer32"},
1392
+ },
1393
+ "access" : "readwrite",
1394
+ "default" : "600",
1395
+ "description" :
1396
+ """The time in seconds since the last packet seen, after which
1397
+ a flow becomes 'idle.' Note that although a flow may be
1398
+ idle, it will not be discarded (and its memory recovered)
1399
+ until after its data has been collected by all the meter
1400
+ readers registered for its RuleSet.""",
1401
+ }, # scalar
1402
+ "flowActiveFlows" : {
1403
+ "nodetype" : "scalar",
1404
+ "moduleName" : "FLOW-METER-MIB",
1405
+ "oid" : "1.3.6.1.2.1.40.1.7",
1406
+ "status" : "current",
1407
+ "syntax" : {
1408
+ "type" : { "module" :"", "name" : "Integer32"},
1409
+ },
1410
+ "access" : "readonly",
1411
+ "description" :
1412
+ """The number of flows which are currently in use.""",
1413
+ }, # scalar
1414
+ "flowMaxFlows" : {
1415
+ "nodetype" : "scalar",
1416
+ "moduleName" : "FLOW-METER-MIB",
1417
+ "oid" : "1.3.6.1.2.1.40.1.8",
1418
+ "status" : "current",
1419
+ "syntax" : {
1420
+ "type" : { "module" :"", "name" : "Integer32"},
1421
+ },
1422
+ "access" : "readonly",
1423
+ "description" :
1424
+ """The maximum number of flows allowed in the meter's
1425
+ flow table. At present this is determined when the meter
1426
+ is first started up.""",
1427
+ }, # scalar
1428
+ "flowFloodMode" : {
1429
+ "nodetype" : "scalar",
1430
+ "moduleName" : "FLOW-METER-MIB",
1431
+ "oid" : "1.3.6.1.2.1.40.1.9",
1432
+ "status" : "current",
1433
+ "syntax" : {
1434
+ "type" : { "module" :"SNMPv2-TC", "name" : "TruthValue"},
1435
+ },
1436
+ "access" : "readwrite",
1437
+ "description" :
1438
+ """Indicates that the meter has passed its FloodMark and is
1439
+ not running in its normal mode.
1440
+
1441
+ When the manager notices this it should take action to remedy
1442
+ the problem which caused the flooding. It should then monitor
1443
+ flowActiveFlows so as to determine when the flood has receded.
1444
+ At that point the manager may set flowFloodMode to false(2) to
1445
+ resume normal operation.""",
1446
+ }, # scalar
1447
+ "flowData" : {
1448
+ "nodetype" : "node",
1449
+ "moduleName" : "FLOW-METER-MIB",
1450
+ "oid" : "1.3.6.1.2.1.40.2",
1451
+ }, # node
1452
+ "flowDataTable" : {
1453
+ "nodetype" : "table",
1454
+ "moduleName" : "FLOW-METER-MIB",
1455
+ "oid" : "1.3.6.1.2.1.40.2.1",
1456
+ "status" : "current",
1457
+ "description" :
1458
+ """The list of all flows being measured.""",
1459
+ }, # table
1460
+ "flowDataEntry" : {
1461
+ "nodetype" : "row",
1462
+ "moduleName" : "FLOW-METER-MIB",
1463
+ "oid" : "1.3.6.1.2.1.40.2.1.1",
1464
+ "status" : "current",
1465
+ "linkage" : [
1466
+ "flowDataRuleSet",
1467
+ "flowDataTimeMark",
1468
+ "flowDataIndex",
1469
+ ],
1470
+ "description" :
1471
+ """The flow data record for a particular flow.""",
1472
+ }, # row
1473
+ "flowDataIndex" : {
1474
+ "nodetype" : "column",
1475
+ "moduleName" : "FLOW-METER-MIB",
1476
+ "oid" : "1.3.6.1.2.1.40.2.1.1.1",
1477
+ "status" : "current",
1478
+ "syntax" : {
1479
+ "type" : {
1480
+ "basetype" : "Integer32",
1481
+ "ranges" : [
1482
+ {
1483
+ "min" : "1",
1484
+ "max" : "2147483647"
1485
+ },
1486
+ ],
1487
+ "range" : {
1488
+ "min" : "1",
1489
+ "max" : "2147483647"
1490
+ },
1491
+ },
1492
+ },
1493
+ "access" : "noaccess",
1494
+ "description" :
1495
+ """Value of this flow data record's index within the meter's
1496
+ flow table.""",
1497
+ }, # column
1498
+ "flowDataTimeMark" : {
1499
+ "nodetype" : "column",
1500
+ "moduleName" : "FLOW-METER-MIB",
1501
+ "oid" : "1.3.6.1.2.1.40.2.1.1.2",
1502
+ "status" : "current",
1503
+ "syntax" : {
1504
+ "type" : { "module" :"RMON2-MIB", "name" : "TimeFilter"},
1505
+ },
1506
+ "access" : "noaccess",
1507
+ "description" :
1508
+ """A TimeFilter for this entry. Allows GetNext and GetBulk
1509
+ to find flow table rows which have changed since a specified
1510
+ value of the meter's Uptime.""",
1511
+ }, # column
1512
+ "flowDataStatus" : {
1513
+ "nodetype" : "column",
1514
+ "moduleName" : "FLOW-METER-MIB",
1515
+ "oid" : "1.3.6.1.2.1.40.2.1.1.3",
1516
+ "status" : "deprecated",
1517
+ "syntax" : {
1518
+ "type" : {
1519
+ "basetype" : "Enumeration",
1520
+ "inactive" : {
1521
+ "nodetype" : "namednumber",
1522
+ "number" : "1"
1523
+ },
1524
+ "current" : {
1525
+ "nodetype" : "namednumber",
1526
+ "number" : "2"
1527
+ },
1528
+ },
1529
+ },
1530
+ "access" : "readonly",
1531
+ "description" :
1532
+ """Status of this flow data record.""",
1533
+ }, # column
1534
+ "flowDataSourceInterface" : {
1535
+ "nodetype" : "column",
1536
+ "moduleName" : "FLOW-METER-MIB",
1537
+ "oid" : "1.3.6.1.2.1.40.2.1.1.4",
1538
+ "status" : "current",
1539
+ "syntax" : {
1540
+ "type" : { "module" :"", "name" : "Integer32"},
1541
+ },
1542
+ "access" : "readonly",
1543
+ "description" :
1544
+ """Index of the interface associated with the source address
1545
+ for this flow. It's value is one of those contained in the
1546
+ ifIndex field of the meter's interfaces table.""",
1547
+ }, # column
1548
+ "flowDataSourceAdjacentType" : {
1549
+ "nodetype" : "column",
1550
+ "moduleName" : "FLOW-METER-MIB",
1551
+ "oid" : "1.3.6.1.2.1.40.2.1.1.5",
1552
+ "status" : "current",
1553
+ "syntax" : {
1554
+ "type" : { "module" :"FLOW-METER-MIB", "name" : "AdjacentType"},
1555
+ },
1556
+ "access" : "readonly",
1557
+ "description" :
1558
+ """Adjacent address type of the source for this flow.
1559
+
1560
+ If metering is being performed at the network level,
1561
+ AdjacentType will indicate the medium for the interface on
1562
+ which the flow was observed and AdjacentAddress will be the
1563
+ MAC address for that interface. This is the usual case.
1564
+
1565
+ If traffic is being metered inside a tunnel, AdjacentType will
1566
+ be the peer type of the host at the end of the tunnel and
1567
+ AdjacentAddress will be the peer address for that host.""",
1568
+ }, # column
1569
+ "flowDataSourceAdjacentAddress" : {
1570
+ "nodetype" : "column",
1571
+ "moduleName" : "FLOW-METER-MIB",
1572
+ "oid" : "1.3.6.1.2.1.40.2.1.1.6",
1573
+ "status" : "current",
1574
+ "syntax" : {
1575
+ "type" : { "module" :"FLOW-METER-MIB", "name" : "AdjacentAddress"},
1576
+ },
1577
+ "access" : "readonly",
1578
+ "description" :
1579
+ """Address of the adjacent device on the path for the source
1580
+ for this flow.""",
1581
+ }, # column
1582
+ "flowDataSourceAdjacentMask" : {
1583
+ "nodetype" : "column",
1584
+ "moduleName" : "FLOW-METER-MIB",
1585
+ "oid" : "1.3.6.1.2.1.40.2.1.1.7",
1586
+ "status" : "current",
1587
+ "syntax" : {
1588
+ "type" : { "module" :"FLOW-METER-MIB", "name" : "AdjacentAddress"},
1589
+ },
1590
+ "access" : "readonly",
1591
+ "description" :
1592
+ """1-bits in this mask indicate which bits must match when
1593
+ comparing the adjacent source address for this flow.""",
1594
+ }, # column
1595
+ "flowDataSourcePeerType" : {
1596
+ "nodetype" : "column",
1597
+ "moduleName" : "FLOW-METER-MIB",
1598
+ "oid" : "1.3.6.1.2.1.40.2.1.1.8",
1599
+ "status" : "current",
1600
+ "syntax" : {
1601
+ "type" : { "module" :"FLOW-METER-MIB", "name" : "PeerType"},
1602
+ },
1603
+ "access" : "readonly",
1604
+ "description" :
1605
+ """Peer address type of the source for this flow.""",
1606
+ }, # column
1607
+ "flowDataSourcePeerAddress" : {
1608
+ "nodetype" : "column",
1609
+ "moduleName" : "FLOW-METER-MIB",
1610
+ "oid" : "1.3.6.1.2.1.40.2.1.1.9",
1611
+ "status" : "current",
1612
+ "syntax" : {
1613
+ "type" : { "module" :"FLOW-METER-MIB", "name" : "PeerAddress"},
1614
+ },
1615
+ "access" : "readonly",
1616
+ "description" :
1617
+ """Address of the peer device for the source of this flow.""",
1618
+ }, # column
1619
+ "flowDataSourcePeerMask" : {
1620
+ "nodetype" : "column",
1621
+ "moduleName" : "FLOW-METER-MIB",
1622
+ "oid" : "1.3.6.1.2.1.40.2.1.1.10",
1623
+ "status" : "current",
1624
+ "syntax" : {
1625
+ "type" : { "module" :"FLOW-METER-MIB", "name" : "PeerAddress"},
1626
+ },
1627
+ "access" : "readonly",
1628
+ "description" :
1629
+ """1-bits in this mask indicate which bits must match when
1630
+ comparing the source peer address for this flow.""",
1631
+ }, # column
1632
+ "flowDataSourceTransType" : {
1633
+ "nodetype" : "column",
1634
+ "moduleName" : "FLOW-METER-MIB",
1635
+ "oid" : "1.3.6.1.2.1.40.2.1.1.11",
1636
+ "status" : "current",
1637
+ "syntax" : {
1638
+ "type" : { "module" :"FLOW-METER-MIB", "name" : "TransportType"},
1639
+ },
1640
+ "access" : "readonly",
1641
+ "description" :
1642
+ """Transport address type of the source for this flow. The
1643
+ value of this attribute will depend on the peer address type.""",
1644
+ }, # column
1645
+ "flowDataSourceTransAddress" : {
1646
+ "nodetype" : "column",
1647
+ "moduleName" : "FLOW-METER-MIB",
1648
+ "oid" : "1.3.6.1.2.1.40.2.1.1.12",
1649
+ "status" : "current",
1650
+ "syntax" : {
1651
+ "type" : { "module" :"FLOW-METER-MIB", "name" : "TransportAddress"},
1652
+ },
1653
+ "access" : "readonly",
1654
+ "description" :
1655
+ """Transport address for the source of this flow.""",
1656
+ }, # column
1657
+ "flowDataSourceTransMask" : {
1658
+ "nodetype" : "column",
1659
+ "moduleName" : "FLOW-METER-MIB",
1660
+ "oid" : "1.3.6.1.2.1.40.2.1.1.13",
1661
+ "status" : "current",
1662
+ "syntax" : {
1663
+ "type" : { "module" :"FLOW-METER-MIB", "name" : "TransportAddress"},
1664
+ },
1665
+ "access" : "readonly",
1666
+ "description" :
1667
+ """1-bits in this mask indicate which bits must match when
1668
+ comparing the transport source address for this flow.""",
1669
+ }, # column
1670
+ "flowDataDestInterface" : {
1671
+ "nodetype" : "column",
1672
+ "moduleName" : "FLOW-METER-MIB",
1673
+ "oid" : "1.3.6.1.2.1.40.2.1.1.14",
1674
+ "status" : "current",
1675
+ "syntax" : {
1676
+ "type" : { "module" :"", "name" : "Integer32"},
1677
+ },
1678
+ "access" : "readonly",
1679
+ "description" :
1680
+ """Index of the interface associated with the dest address for
1681
+ this flow. This value is one of the values contained in the
1682
+ ifIndex field of the interfaces table.""",
1683
+ }, # column
1684
+ "flowDataDestAdjacentType" : {
1685
+ "nodetype" : "column",
1686
+ "moduleName" : "FLOW-METER-MIB",
1687
+ "oid" : "1.3.6.1.2.1.40.2.1.1.15",
1688
+ "status" : "current",
1689
+ "syntax" : {
1690
+ "type" : { "module" :"FLOW-METER-MIB", "name" : "AdjacentType"},
1691
+ },
1692
+ "access" : "readonly",
1693
+ "description" :
1694
+ """Adjacent address type of the destination for this flow.""",
1695
+ }, # column
1696
+ "flowDataDestAdjacentAddress" : {
1697
+ "nodetype" : "column",
1698
+ "moduleName" : "FLOW-METER-MIB",
1699
+ "oid" : "1.3.6.1.2.1.40.2.1.1.16",
1700
+ "status" : "current",
1701
+ "syntax" : {
1702
+ "type" : { "module" :"FLOW-METER-MIB", "name" : "AdjacentAddress"},
1703
+ },
1704
+ "access" : "readonly",
1705
+ "description" :
1706
+ """Address of the adjacent device on the path for the
1707
+ destination for this flow.""",
1708
+ }, # column
1709
+ "flowDataDestAdjacentMask" : {
1710
+ "nodetype" : "column",
1711
+ "moduleName" : "FLOW-METER-MIB",
1712
+ "oid" : "1.3.6.1.2.1.40.2.1.1.17",
1713
+ "status" : "current",
1714
+ "syntax" : {
1715
+ "type" : { "module" :"FLOW-METER-MIB", "name" : "AdjacentAddress"},
1716
+ },
1717
+ "access" : "readonly",
1718
+ "description" :
1719
+ """1-bits in this mask indicate which bits must match when
1720
+ comparing the adjacent destination address for this flow.""",
1721
+ }, # column
1722
+ "flowDataDestPeerType" : {
1723
+ "nodetype" : "column",
1724
+ "moduleName" : "FLOW-METER-MIB",
1725
+ "oid" : "1.3.6.1.2.1.40.2.1.1.18",
1726
+ "status" : "current",
1727
+ "syntax" : {
1728
+ "type" : { "module" :"FLOW-METER-MIB", "name" : "PeerType"},
1729
+ },
1730
+ "access" : "readonly",
1731
+ "description" :
1732
+ """Peer address type of the destination for this flow.""",
1733
+ }, # column
1734
+ "flowDataDestPeerAddress" : {
1735
+ "nodetype" : "column",
1736
+ "moduleName" : "FLOW-METER-MIB",
1737
+ "oid" : "1.3.6.1.2.1.40.2.1.1.19",
1738
+ "status" : "current",
1739
+ "syntax" : {
1740
+ "type" : { "module" :"FLOW-METER-MIB", "name" : "PeerAddress"},
1741
+ },
1742
+ "access" : "readonly",
1743
+ "description" :
1744
+ """Address of the peer device for the destination of this flow.""",
1745
+ }, # column
1746
+ "flowDataDestPeerMask" : {
1747
+ "nodetype" : "column",
1748
+ "moduleName" : "FLOW-METER-MIB",
1749
+ "oid" : "1.3.6.1.2.1.40.2.1.1.20",
1750
+ "status" : "current",
1751
+ "syntax" : {
1752
+ "type" : { "module" :"FLOW-METER-MIB", "name" : "PeerAddress"},
1753
+ },
1754
+ "access" : "readonly",
1755
+ "description" :
1756
+ """1-bits in this mask indicate which bits must match when
1757
+ comparing the destination peer type for this flow.""",
1758
+ }, # column
1759
+ "flowDataDestTransType" : {
1760
+ "nodetype" : "column",
1761
+ "moduleName" : "FLOW-METER-MIB",
1762
+ "oid" : "1.3.6.1.2.1.40.2.1.1.21",
1763
+ "status" : "current",
1764
+ "syntax" : {
1765
+ "type" : { "module" :"FLOW-METER-MIB", "name" : "TransportType"},
1766
+ },
1767
+ "access" : "readonly",
1768
+ "description" :
1769
+ """Transport address type of the destination for this flow. The
1770
+ value of this attribute will depend on the peer address type.""",
1771
+ }, # column
1772
+ "flowDataDestTransAddress" : {
1773
+ "nodetype" : "column",
1774
+ "moduleName" : "FLOW-METER-MIB",
1775
+ "oid" : "1.3.6.1.2.1.40.2.1.1.22",
1776
+ "status" : "current",
1777
+ "syntax" : {
1778
+ "type" : { "module" :"FLOW-METER-MIB", "name" : "TransportAddress"},
1779
+ },
1780
+ "access" : "readonly",
1781
+ "description" :
1782
+ """Transport address for the destination of this flow.""",
1783
+ }, # column
1784
+ "flowDataDestTransMask" : {
1785
+ "nodetype" : "column",
1786
+ "moduleName" : "FLOW-METER-MIB",
1787
+ "oid" : "1.3.6.1.2.1.40.2.1.1.23",
1788
+ "status" : "current",
1789
+ "syntax" : {
1790
+ "type" : { "module" :"FLOW-METER-MIB", "name" : "TransportAddress"},
1791
+ },
1792
+ "access" : "readonly",
1793
+ "description" :
1794
+ """1-bits in this mask indicate which bits must match when
1795
+ comparing the transport destination address for this flow.""",
1796
+ }, # column
1797
+ "flowDataPDUScale" : {
1798
+ "nodetype" : "column",
1799
+ "moduleName" : "FLOW-METER-MIB",
1800
+ "oid" : "1.3.6.1.2.1.40.2.1.1.24",
1801
+ "status" : "current",
1802
+ "syntax" : {
1803
+ "type" : {
1804
+ "basetype" : "Integer32",
1805
+ "ranges" : [
1806
+ {
1807
+ "min" : "0",
1808
+ "max" : "255"
1809
+ },
1810
+ ],
1811
+ "range" : {
1812
+ "min" : "0",
1813
+ "max" : "255"
1814
+ },
1815
+ },
1816
+ },
1817
+ "access" : "readonly",
1818
+ "description" :
1819
+ """The scale factor applied to this particular flow. Indicates
1820
+ the number of bits the PDU counter values should be moved left
1821
+ to obtain the actual values.""",
1822
+ }, # column
1823
+ "flowDataOctetScale" : {
1824
+ "nodetype" : "column",
1825
+ "moduleName" : "FLOW-METER-MIB",
1826
+ "oid" : "1.3.6.1.2.1.40.2.1.1.25",
1827
+ "status" : "current",
1828
+ "syntax" : {
1829
+ "type" : {
1830
+ "basetype" : "Integer32",
1831
+ "ranges" : [
1832
+ {
1833
+ "min" : "0",
1834
+ "max" : "255"
1835
+ },
1836
+ ],
1837
+ "range" : {
1838
+ "min" : "0",
1839
+ "max" : "255"
1840
+ },
1841
+ },
1842
+ },
1843
+ "access" : "readonly",
1844
+ "description" :
1845
+ """The scale factor applied to this particular flow. Indicates
1846
+ the number of bits the octet counter values should be moved
1847
+ left to obtain the actual values.""",
1848
+ }, # column
1849
+ "flowDataRuleSet" : {
1850
+ "nodetype" : "column",
1851
+ "moduleName" : "FLOW-METER-MIB",
1852
+ "oid" : "1.3.6.1.2.1.40.2.1.1.26",
1853
+ "status" : "current",
1854
+ "syntax" : {
1855
+ "type" : {
1856
+ "basetype" : "Integer32",
1857
+ "ranges" : [
1858
+ {
1859
+ "min" : "1",
1860
+ "max" : "255"
1861
+ },
1862
+ ],
1863
+ "range" : {
1864
+ "min" : "1",
1865
+ "max" : "255"
1866
+ },
1867
+ },
1868
+ },
1869
+ "access" : "noaccess",
1870
+ "description" :
1871
+ """The RuleSet number of the RuleSet which created this flow.
1872
+ Allows a manager to use GetNext or GetBulk requests to find
1873
+ flows belonging to a particular RuleSet.""",
1874
+ }, # column
1875
+ "flowDataToOctets" : {
1876
+ "nodetype" : "column",
1877
+ "moduleName" : "FLOW-METER-MIB",
1878
+ "oid" : "1.3.6.1.2.1.40.2.1.1.27",
1879
+ "status" : "current",
1880
+ "syntax" : {
1881
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter64"},
1882
+ },
1883
+ "access" : "readonly",
1884
+ "description" :
1885
+ """The count of octets flowing from source to destination
1886
+ for this flow.""",
1887
+ }, # column
1888
+ "flowDataToPDUs" : {
1889
+ "nodetype" : "column",
1890
+ "moduleName" : "FLOW-METER-MIB",
1891
+ "oid" : "1.3.6.1.2.1.40.2.1.1.28",
1892
+ "status" : "current",
1893
+ "syntax" : {
1894
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter64"},
1895
+ },
1896
+ "access" : "readonly",
1897
+ "description" :
1898
+ """The count of packets flowing from source to destination
1899
+ for this flow.""",
1900
+ }, # column
1901
+ "flowDataFromOctets" : {
1902
+ "nodetype" : "column",
1903
+ "moduleName" : "FLOW-METER-MIB",
1904
+ "oid" : "1.3.6.1.2.1.40.2.1.1.29",
1905
+ "status" : "current",
1906
+ "syntax" : {
1907
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter64"},
1908
+ },
1909
+ "access" : "readonly",
1910
+ "description" :
1911
+ """The count of octets flowing from destination to source
1912
+ for this flow.""",
1913
+ }, # column
1914
+ "flowDataFromPDUs" : {
1915
+ "nodetype" : "column",
1916
+ "moduleName" : "FLOW-METER-MIB",
1917
+ "oid" : "1.3.6.1.2.1.40.2.1.1.30",
1918
+ "status" : "current",
1919
+ "syntax" : {
1920
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter64"},
1921
+ },
1922
+ "access" : "readonly",
1923
+ "description" :
1924
+ """The count of packets flowing from destination to source
1925
+ for this flow.""",
1926
+ }, # column
1927
+ "flowDataFirstTime" : {
1928
+ "nodetype" : "column",
1929
+ "moduleName" : "FLOW-METER-MIB",
1930
+ "oid" : "1.3.6.1.2.1.40.2.1.1.31",
1931
+ "status" : "current",
1932
+ "syntax" : {
1933
+ "type" : { "module" :"SNMPv2-TC", "name" : "TimeStamp"},
1934
+ },
1935
+ "access" : "readonly",
1936
+ "description" :
1937
+ """The time at which this flow was first entered in the table""",
1938
+ }, # column
1939
+ "flowDataLastActiveTime" : {
1940
+ "nodetype" : "column",
1941
+ "moduleName" : "FLOW-METER-MIB",
1942
+ "oid" : "1.3.6.1.2.1.40.2.1.1.32",
1943
+ "status" : "current",
1944
+ "syntax" : {
1945
+ "type" : { "module" :"SNMPv2-TC", "name" : "TimeStamp"},
1946
+ },
1947
+ "access" : "readonly",
1948
+ "description" :
1949
+ """The last time this flow had activity, i.e. the time of
1950
+ arrival of the most recent PDU belonging to this flow.""",
1951
+ }, # column
1952
+ "flowDataSourceSubscriberID" : {
1953
+ "nodetype" : "column",
1954
+ "moduleName" : "FLOW-METER-MIB",
1955
+ "oid" : "1.3.6.1.2.1.40.2.1.1.33",
1956
+ "status" : "current",
1957
+ "syntax" : {
1958
+ "type" : {
1959
+ "basetype" : "OctetString",
1960
+ "ranges" : [
1961
+ {
1962
+ "min" : "4",
1963
+ "max" : "20"
1964
+ },
1965
+ ],
1966
+ "range" : {
1967
+ "min" : "4",
1968
+ "max" : "20"
1969
+ },
1970
+ },
1971
+ },
1972
+ "access" : "readonly",
1973
+ "description" :
1974
+ """Subscriber ID associated with the source address for this
1975
+ flow. A Subscriber ID is an unspecified text string, used
1976
+ to ascribe traffic flows to individual users. At this time
1977
+ the means by which a Subscriber ID may be associated with a
1978
+ flow is unspecified.""",
1979
+ }, # column
1980
+ "flowDataDestSubscriberID" : {
1981
+ "nodetype" : "column",
1982
+ "moduleName" : "FLOW-METER-MIB",
1983
+ "oid" : "1.3.6.1.2.1.40.2.1.1.34",
1984
+ "status" : "current",
1985
+ "syntax" : {
1986
+ "type" : {
1987
+ "basetype" : "OctetString",
1988
+ "ranges" : [
1989
+ {
1990
+ "min" : "4",
1991
+ "max" : "20"
1992
+ },
1993
+ ],
1994
+ "range" : {
1995
+ "min" : "4",
1996
+ "max" : "20"
1997
+ },
1998
+ },
1999
+ },
2000
+ "access" : "readonly",
2001
+ "description" :
2002
+ """Subscriber ID associated with the destination address for
2003
+ this flow. A Subscriber ID is an unspecified text string,
2004
+ used to ascribe traffic flows to individual users. At this
2005
+ time the means by which a Subscriber ID may be associated
2006
+ with a flow is unspecified.""",
2007
+ }, # column
2008
+ "flowDataSessionID" : {
2009
+ "nodetype" : "column",
2010
+ "moduleName" : "FLOW-METER-MIB",
2011
+ "oid" : "1.3.6.1.2.1.40.2.1.1.35",
2012
+ "status" : "current",
2013
+ "syntax" : {
2014
+ "type" : {
2015
+ "basetype" : "OctetString",
2016
+ "ranges" : [
2017
+ {
2018
+ "min" : "4",
2019
+ "max" : "10"
2020
+ },
2021
+ ],
2022
+ "range" : {
2023
+ "min" : "4",
2024
+ "max" : "10"
2025
+ },
2026
+ },
2027
+ },
2028
+ "access" : "readonly",
2029
+ "description" :
2030
+ """Session ID for this flow. Such an ID might be allocated
2031
+ by a network access server to distinguish a series of sessions
2032
+ between the same pair of addresses, which would otherwise
2033
+ appear to be parts of the same accounting flow.""",
2034
+ }, # column
2035
+ "flowDataSourceClass" : {
2036
+ "nodetype" : "column",
2037
+ "moduleName" : "FLOW-METER-MIB",
2038
+ "oid" : "1.3.6.1.2.1.40.2.1.1.36",
2039
+ "status" : "current",
2040
+ "syntax" : {
2041
+ "type" : {
2042
+ "basetype" : "Integer32",
2043
+ "ranges" : [
2044
+ {
2045
+ "min" : "1",
2046
+ "max" : "255"
2047
+ },
2048
+ ],
2049
+ "range" : {
2050
+ "min" : "1",
2051
+ "max" : "255"
2052
+ },
2053
+ },
2054
+ },
2055
+ "access" : "readonly",
2056
+ "description" :
2057
+ """Source class for this flow. Determined by the rules, set by
2058
+ a PushRule action when this flow was entered in the table.""",
2059
+ }, # column
2060
+ "flowDataDestClass" : {
2061
+ "nodetype" : "column",
2062
+ "moduleName" : "FLOW-METER-MIB",
2063
+ "oid" : "1.3.6.1.2.1.40.2.1.1.37",
2064
+ "status" : "current",
2065
+ "syntax" : {
2066
+ "type" : {
2067
+ "basetype" : "Integer32",
2068
+ "ranges" : [
2069
+ {
2070
+ "min" : "1",
2071
+ "max" : "255"
2072
+ },
2073
+ ],
2074
+ "range" : {
2075
+ "min" : "1",
2076
+ "max" : "255"
2077
+ },
2078
+ },
2079
+ },
2080
+ "access" : "readonly",
2081
+ "description" :
2082
+ """Destination class for this flow. Determined by the rules, set
2083
+ by a PushRule action when this flow was entered in the table.""",
2084
+ }, # column
2085
+ "flowDataClass" : {
2086
+ "nodetype" : "column",
2087
+ "moduleName" : "FLOW-METER-MIB",
2088
+ "oid" : "1.3.6.1.2.1.40.2.1.1.38",
2089
+ "status" : "current",
2090
+ "syntax" : {
2091
+ "type" : {
2092
+ "basetype" : "Integer32",
2093
+ "ranges" : [
2094
+ {
2095
+ "min" : "1",
2096
+ "max" : "255"
2097
+ },
2098
+ ],
2099
+ "range" : {
2100
+ "min" : "1",
2101
+ "max" : "255"
2102
+ },
2103
+ },
2104
+ },
2105
+ "access" : "readonly",
2106
+ "description" :
2107
+ """Class for this flow. Determined by the rules, set by a
2108
+ PushRule action when this flow was entered in the table.""",
2109
+ }, # column
2110
+ "flowDataSourceKind" : {
2111
+ "nodetype" : "column",
2112
+ "moduleName" : "FLOW-METER-MIB",
2113
+ "oid" : "1.3.6.1.2.1.40.2.1.1.39",
2114
+ "status" : "current",
2115
+ "syntax" : {
2116
+ "type" : {
2117
+ "basetype" : "Integer32",
2118
+ "ranges" : [
2119
+ {
2120
+ "min" : "1",
2121
+ "max" : "255"
2122
+ },
2123
+ ],
2124
+ "range" : {
2125
+ "min" : "1",
2126
+ "max" : "255"
2127
+ },
2128
+ },
2129
+ },
2130
+ "access" : "readonly",
2131
+ "description" :
2132
+ """Source kind for this flow. Determined by the rules, set by
2133
+ a PushRule action when this flow was entered in the table.""",
2134
+ }, # column
2135
+ "flowDataDestKind" : {
2136
+ "nodetype" : "column",
2137
+ "moduleName" : "FLOW-METER-MIB",
2138
+ "oid" : "1.3.6.1.2.1.40.2.1.1.40",
2139
+ "status" : "current",
2140
+ "syntax" : {
2141
+ "type" : {
2142
+ "basetype" : "Integer32",
2143
+ "ranges" : [
2144
+ {
2145
+ "min" : "1",
2146
+ "max" : "255"
2147
+ },
2148
+ ],
2149
+ "range" : {
2150
+ "min" : "1",
2151
+ "max" : "255"
2152
+ },
2153
+ },
2154
+ },
2155
+ "access" : "readonly",
2156
+ "description" :
2157
+ """Destination kind for this flow. Determined by the rules, set
2158
+ by a PushRule action when this flow was entered in the table.""",
2159
+ }, # column
2160
+ "flowDataKind" : {
2161
+ "nodetype" : "column",
2162
+ "moduleName" : "FLOW-METER-MIB",
2163
+ "oid" : "1.3.6.1.2.1.40.2.1.1.41",
2164
+ "status" : "current",
2165
+ "syntax" : {
2166
+ "type" : {
2167
+ "basetype" : "Integer32",
2168
+ "ranges" : [
2169
+ {
2170
+ "min" : "1",
2171
+ "max" : "255"
2172
+ },
2173
+ ],
2174
+ "range" : {
2175
+ "min" : "1",
2176
+ "max" : "255"
2177
+ },
2178
+ },
2179
+ },
2180
+ "access" : "readonly",
2181
+ "description" :
2182
+ """Class for this flow. Determined by the rules, set by a
2183
+ PushRule action when this flow was entered in the table.""",
2184
+ }, # column
2185
+ "flowColumnActivityTable" : {
2186
+ "nodetype" : "table",
2187
+ "moduleName" : "FLOW-METER-MIB",
2188
+ "oid" : "1.3.6.1.2.1.40.2.2",
2189
+ "status" : "deprecated",
2190
+ "description" :
2191
+ """Index into the Flow Table. Allows a meter reader to retrieve
2192
+ a list containing the flow table indexes of flows which were
2193
+ last active at or after a given time, together with the values
2194
+ of a specified attribute for each such flow.""",
2195
+ }, # table
2196
+ "flowColumnActivityEntry" : {
2197
+ "nodetype" : "row",
2198
+ "moduleName" : "FLOW-METER-MIB",
2199
+ "oid" : "1.3.6.1.2.1.40.2.2.1",
2200
+ "status" : "deprecated",
2201
+ "linkage" : [
2202
+ "flowColumnActivityAttribute",
2203
+ "flowColumnActivityTime",
2204
+ "flowColumnActivityIndex",
2205
+ ],
2206
+ "description" :
2207
+ """The Column Activity Entry for a particular attribute,
2208
+ activity time and flow.""",
2209
+ }, # row
2210
+ "flowColumnActivityAttribute" : {
2211
+ "nodetype" : "column",
2212
+ "moduleName" : "FLOW-METER-MIB",
2213
+ "oid" : "1.3.6.1.2.1.40.2.2.1.1",
2214
+ "status" : "deprecated",
2215
+ "syntax" : {
2216
+ "type" : { "module" :"FLOW-METER-MIB", "name" : "FlowAttributeNumber"},
2217
+ },
2218
+ "access" : "readonly",
2219
+ "description" :
2220
+ """Specifies the attribute for which values are required from
2221
+ active flows.""",
2222
+ }, # column
2223
+ "flowColumnActivityTime" : {
2224
+ "nodetype" : "column",
2225
+ "moduleName" : "FLOW-METER-MIB",
2226
+ "oid" : "1.3.6.1.2.1.40.2.2.1.2",
2227
+ "status" : "deprecated",
2228
+ "syntax" : {
2229
+ "type" : { "module" :"RMON2-MIB", "name" : "TimeFilter"},
2230
+ },
2231
+ "access" : "readonly",
2232
+ "description" :
2233
+ """This variable is a copy of flowDataLastActiveTime in the
2234
+ flow data record identified by the flowColumnActivityIndex
2235
+ value of this flowColumnActivityTable entry.""",
2236
+ }, # column
2237
+ "flowColumnActivityIndex" : {
2238
+ "nodetype" : "column",
2239
+ "moduleName" : "FLOW-METER-MIB",
2240
+ "oid" : "1.3.6.1.2.1.40.2.2.1.3",
2241
+ "status" : "deprecated",
2242
+ "syntax" : {
2243
+ "type" : {
2244
+ "basetype" : "Integer32",
2245
+ "ranges" : [
2246
+ {
2247
+ "min" : "1",
2248
+ "max" : "2147483647"
2249
+ },
2250
+ ],
2251
+ "range" : {
2252
+ "min" : "1",
2253
+ "max" : "2147483647"
2254
+ },
2255
+ },
2256
+ },
2257
+ "access" : "readonly",
2258
+ "description" :
2259
+ """Index of a flow table entry which was active at or after
2260
+ a specified flowColumnActivityTime.""",
2261
+ }, # column
2262
+ "flowColumnActivityData" : {
2263
+ "nodetype" : "column",
2264
+ "moduleName" : "FLOW-METER-MIB",
2265
+ "oid" : "1.3.6.1.2.1.40.2.2.1.4",
2266
+ "status" : "deprecated",
2267
+ "syntax" : {
2268
+ "type" : {
2269
+ "basetype" : "OctetString",
2270
+ "ranges" : [
2271
+ {
2272
+ "min" : "3",
2273
+ "max" : "1000"
2274
+ },
2275
+ ],
2276
+ "range" : {
2277
+ "min" : "3",
2278
+ "max" : "1000"
2279
+ },
2280
+ },
2281
+ },
2282
+ "access" : "readonly",
2283
+ "description" :
2284
+ """Collection of attribute data for flows active after
2285
+ flowColumnActivityTime. Within the OCTET STRING is a
2286
+ sequence of { flow index, attribute value } pairs, one for
2287
+ each active flow. The end of the sequence is marked by a
2288
+ flow index value of 0, indicating that there are no more
2289
+ rows in this column.
2290
+
2291
+ The format of objects inside flowColumnFlowData is as follows.
2292
+ All numbers are unsigned. Numbers and strings appear with
2293
+ their high-order bytes leading. Numbers are fixed size, as
2294
+ specified by their SYNTAX in the flow table (above), i.e. one
2295
+ octet for flowAddressType and small constants, and four octets
2296
+ for Counter and TimeStamp. Strings are variable-length, with
2297
+ the length given in a single leading octet.
2298
+
2299
+ The following is an attempt at an ASN.1 definition of
2300
+ flowColumnActivityData:
2301
+
2302
+ flowColumnActivityData ::= SEQUENCE flowRowItemEntry
2303
+ flowRowItemEntry ::= SEQUENCE {
2304
+ flowRowNumber Integer32 (1..65535),
2305
+ -- 0 indicates the end of this column
2306
+ flowDataValue flowDataType -- Choice depends on attribute
2307
+ }
2308
+ flowDataType ::= CHOICE {
2309
+ flowByteValue Integer32 (1..255),
2310
+ flowShortValue Integer32 (1..65535),
2311
+ flowLongValue Integer32,
2312
+ flowStringValue OCTET STRING -- Length (n) in first byte,
2313
+ -- n+1 bytes total length, trailing zeroes truncated
2314
+ }""",
2315
+ }, # column
2316
+ "flowDataPackageTable" : {
2317
+ "nodetype" : "table",
2318
+ "moduleName" : "FLOW-METER-MIB",
2319
+ "oid" : "1.3.6.1.2.1.40.2.3",
2320
+ "status" : "current",
2321
+ "description" :
2322
+ """Index into the Flow Table. Allows a meter reader to retrieve
2323
+ a sequence containing the values of a specified set of
2324
+ attributes for a flow which came from a specified RuleSet and
2325
+ which was last active at or after a given time.""",
2326
+ }, # table
2327
+ "flowDataPackageEntry" : {
2328
+ "nodetype" : "row",
2329
+ "moduleName" : "FLOW-METER-MIB",
2330
+ "oid" : "1.3.6.1.2.1.40.2.3.1",
2331
+ "status" : "current",
2332
+ "linkage" : [
2333
+ "flowPackageSelector",
2334
+ "flowPackageRuleSet",
2335
+ "flowPackageTime",
2336
+ "flowPackageIndex",
2337
+ ],
2338
+ "description" :
2339
+ """The data package containing selected variables from
2340
+ active rows in the flow table.""",
2341
+ }, # row
2342
+ "flowPackageSelector" : {
2343
+ "nodetype" : "column",
2344
+ "moduleName" : "FLOW-METER-MIB",
2345
+ "oid" : "1.3.6.1.2.1.40.2.3.1.1",
2346
+ "status" : "current",
2347
+ "syntax" : {
2348
+ "type" : { "module" :"", "name" : "OctetString"},
2349
+ },
2350
+ "access" : "noaccess",
2351
+ "description" :
2352
+ """Specifies the attributes for which values are required from
2353
+ an active flow. These are encoded as a sequence of octets
2354
+ each containing a FlowAttribute number, preceded by an octet
2355
+ giving the length of the sequence (not including the length
2356
+ octet). For a flowPackageSelector to be valid, it must
2357
+ contain at least one attribute.""",
2358
+ }, # column
2359
+ "flowPackageRuleSet" : {
2360
+ "nodetype" : "column",
2361
+ "moduleName" : "FLOW-METER-MIB",
2362
+ "oid" : "1.3.6.1.2.1.40.2.3.1.2",
2363
+ "status" : "current",
2364
+ "syntax" : {
2365
+ "type" : {
2366
+ "basetype" : "Integer32",
2367
+ "ranges" : [
2368
+ {
2369
+ "min" : "1",
2370
+ "max" : "255"
2371
+ },
2372
+ ],
2373
+ "range" : {
2374
+ "min" : "1",
2375
+ "max" : "255"
2376
+ },
2377
+ },
2378
+ },
2379
+ "access" : "noaccess",
2380
+ "description" :
2381
+ """Specifies the index (in the flowRuleSetInfoTable) of the rule
2382
+ set which produced the required flow.""",
2383
+ }, # column
2384
+ "flowPackageTime" : {
2385
+ "nodetype" : "column",
2386
+ "moduleName" : "FLOW-METER-MIB",
2387
+ "oid" : "1.3.6.1.2.1.40.2.3.1.3",
2388
+ "status" : "current",
2389
+ "syntax" : {
2390
+ "type" : { "module" :"RMON2-MIB", "name" : "TimeFilter"},
2391
+ },
2392
+ "access" : "noaccess",
2393
+ "description" :
2394
+ """This variable is a copy of flowDataLastActiveTime in the
2395
+ flow data record identified by the flowPackageIndex
2396
+ value of this flowPackageTable entry.""",
2397
+ }, # column
2398
+ "flowPackageIndex" : {
2399
+ "nodetype" : "column",
2400
+ "moduleName" : "FLOW-METER-MIB",
2401
+ "oid" : "1.3.6.1.2.1.40.2.3.1.4",
2402
+ "status" : "current",
2403
+ "syntax" : {
2404
+ "type" : {
2405
+ "basetype" : "Integer32",
2406
+ "ranges" : [
2407
+ {
2408
+ "min" : "1",
2409
+ "max" : "2147483647"
2410
+ },
2411
+ ],
2412
+ "range" : {
2413
+ "min" : "1",
2414
+ "max" : "2147483647"
2415
+ },
2416
+ },
2417
+ },
2418
+ "access" : "noaccess",
2419
+ "description" :
2420
+ """Index of a flow table entry which was active at or after
2421
+ a specified flowPackageTime.""",
2422
+ }, # column
2423
+ "flowPackageData" : {
2424
+ "nodetype" : "column",
2425
+ "moduleName" : "FLOW-METER-MIB",
2426
+ "oid" : "1.3.6.1.2.1.40.2.3.1.5",
2427
+ "status" : "current",
2428
+ "syntax" : {
2429
+ "type" : { "module" :"", "name" : "OctetString"},
2430
+ },
2431
+ "access" : "readonly",
2432
+ "description" :
2433
+ """A collection of attribute values for a single flow, as
2434
+ specified by this row's indexes. The attribute values are
2435
+ contained within a BER-encoded sequence [ASN-1, ASN-BER],
2436
+ in the order they appear in their flowPackageSelector.
2437
+
2438
+ For example, to retrieve a flowPackage containing values for
2439
+ attributes 11, 18 and 29, for a flow in RuleSet 7, with flow
2440
+ index 3447, one would GET the package whose Object Identifier
2441
+ (OID) is
2442
+ flowPackageData . 3.11.18.29 . 7. 0 . 3447
2443
+
2444
+ To get a package for the next such flow which had been
2445
+ active since time 12345 one would GETNEXT the package whose
2446
+ Object Identifier (OID) is
2447
+ flowPackageData . 3.11.18.29 . 7. 12345 . 3447""",
2448
+ }, # column
2449
+ "flowRules" : {
2450
+ "nodetype" : "node",
2451
+ "moduleName" : "FLOW-METER-MIB",
2452
+ "oid" : "1.3.6.1.2.1.40.3",
2453
+ }, # node
2454
+ "flowRuleTable" : {
2455
+ "nodetype" : "table",
2456
+ "moduleName" : "FLOW-METER-MIB",
2457
+ "oid" : "1.3.6.1.2.1.40.3.1",
2458
+ "status" : "current",
2459
+ "description" :
2460
+ """Contains all the RuleSets which may be used by the meter.""",
2461
+ }, # table
2462
+ "flowRuleEntry" : {
2463
+ "nodetype" : "row",
2464
+ "moduleName" : "FLOW-METER-MIB",
2465
+ "oid" : "1.3.6.1.2.1.40.3.1.1",
2466
+ "status" : "current",
2467
+ "linkage" : [
2468
+ "flowRuleSet",
2469
+ "flowRuleIndex",
2470
+ ],
2471
+ "description" :
2472
+ """The rule record itself.""",
2473
+ }, # row
2474
+ "flowRuleSet" : {
2475
+ "nodetype" : "column",
2476
+ "moduleName" : "FLOW-METER-MIB",
2477
+ "oid" : "1.3.6.1.2.1.40.3.1.1.1",
2478
+ "status" : "current",
2479
+ "syntax" : {
2480
+ "type" : {
2481
+ "basetype" : "Integer32",
2482
+ "ranges" : [
2483
+ {
2484
+ "min" : "1",
2485
+ "max" : "2147483647"
2486
+ },
2487
+ ],
2488
+ "range" : {
2489
+ "min" : "1",
2490
+ "max" : "2147483647"
2491
+ },
2492
+ },
2493
+ },
2494
+ "access" : "noaccess",
2495
+ "description" :
2496
+ """Selects a RuleSet from the array of RuleSets.""",
2497
+ }, # column
2498
+ "flowRuleIndex" : {
2499
+ "nodetype" : "column",
2500
+ "moduleName" : "FLOW-METER-MIB",
2501
+ "oid" : "1.3.6.1.2.1.40.3.1.1.2",
2502
+ "status" : "current",
2503
+ "syntax" : {
2504
+ "type" : {
2505
+ "basetype" : "Integer32",
2506
+ "ranges" : [
2507
+ {
2508
+ "min" : "1",
2509
+ "max" : "2147483647"
2510
+ },
2511
+ ],
2512
+ "range" : {
2513
+ "min" : "1",
2514
+ "max" : "2147483647"
2515
+ },
2516
+ },
2517
+ },
2518
+ "access" : "noaccess",
2519
+ "description" :
2520
+ """The index into the Rule table. N.B: These values will
2521
+ normally be consecutive, given the fall-through semantics
2522
+ of processing the table.""",
2523
+ }, # column
2524
+ "flowRuleSelector" : {
2525
+ "nodetype" : "column",
2526
+ "moduleName" : "FLOW-METER-MIB",
2527
+ "oid" : "1.3.6.1.2.1.40.3.1.1.3",
2528
+ "status" : "current",
2529
+ "syntax" : {
2530
+ "type" : { "module" :"FLOW-METER-MIB", "name" : "RuleAttributeNumber"},
2531
+ },
2532
+ "access" : "readwrite",
2533
+ "description" :
2534
+ """Indicates the attribute to be matched.
2535
+
2536
+ null(0) is a special case; null rules always succeed.
2537
+ matchingStoD(50) is set by the meter's Packet Matching Engine.
2538
+ Its value is true(1) if the PME is attempting to match the
2539
+ packet with its addresses in Source-to-Destination order (i.e.
2540
+ as they appear in the packet), and false(2) otherwise.
2541
+ Details of how packets are matched are given in the 'Traffic
2542
+ Flow Measurement: Architecture' document [RTFM-ARC].
2543
+ v1(51), v2(52), v3(53), v4(54) and v5(55) select meter
2544
+ variables, each of which can hold the name (i.e. selector
2545
+ value) of an address attribute. When one of these is used
2546
+ as a selector, its value specifies the attribute to be
2547
+ tested. Variable values are set by an Assign action.""",
2548
+ }, # column
2549
+ "flowRuleMask" : {
2550
+ "nodetype" : "column",
2551
+ "moduleName" : "FLOW-METER-MIB",
2552
+ "oid" : "1.3.6.1.2.1.40.3.1.1.4",
2553
+ "status" : "current",
2554
+ "syntax" : {
2555
+ "type" : { "module" :"FLOW-METER-MIB", "name" : "RuleAddress"},
2556
+ },
2557
+ "access" : "readwrite",
2558
+ "description" :
2559
+ """The initial mask used to compute the desired value. If the
2560
+ mask is zero the rule's test will always succeed.""",
2561
+ }, # column
2562
+ "flowRuleMatchedValue" : {
2563
+ "nodetype" : "column",
2564
+ "moduleName" : "FLOW-METER-MIB",
2565
+ "oid" : "1.3.6.1.2.1.40.3.1.1.5",
2566
+ "status" : "current",
2567
+ "syntax" : {
2568
+ "type" : { "module" :"FLOW-METER-MIB", "name" : "RuleAddress"},
2569
+ },
2570
+ "access" : "readwrite",
2571
+ "description" :
2572
+ """The resulting value to be matched for equality.
2573
+ Specifically, if the attribute chosen by the flowRuleSelector
2574
+ logically ANDed with the mask specified by the flowRuleMask
2575
+ equals the value specified in the flowRuleMatchedValue, then
2576
+ continue processing the table entry based on the action
2577
+ specified by the flowRuleAction entry. Otherwise, proceed to
2578
+ the next entry in the rule table.""",
2579
+ }, # column
2580
+ "flowRuleAction" : {
2581
+ "nodetype" : "column",
2582
+ "moduleName" : "FLOW-METER-MIB",
2583
+ "oid" : "1.3.6.1.2.1.40.3.1.1.6",
2584
+ "status" : "current",
2585
+ "syntax" : {
2586
+ "type" : { "module" :"FLOW-METER-MIB", "name" : "ActionNumber"},
2587
+ },
2588
+ "access" : "readwrite",
2589
+ "description" :
2590
+ """The action to be taken if this rule's test succeeds, or if
2591
+ the meter's 'test' flag is off. Actions are opcodes for the
2592
+ meter's Packet Matching Engine; details are given in the
2593
+ 'Traffic Flow Measurement: Architecture' document [RTFM-ARC].""",
2594
+ }, # column
2595
+ "flowRuleParameter" : {
2596
+ "nodetype" : "column",
2597
+ "moduleName" : "FLOW-METER-MIB",
2598
+ "oid" : "1.3.6.1.2.1.40.3.1.1.7",
2599
+ "status" : "current",
2600
+ "syntax" : {
2601
+ "type" : {
2602
+ "basetype" : "Integer32",
2603
+ "ranges" : [
2604
+ {
2605
+ "min" : "1",
2606
+ "max" : "65535"
2607
+ },
2608
+ ],
2609
+ "range" : {
2610
+ "min" : "1",
2611
+ "max" : "65535"
2612
+ },
2613
+ },
2614
+ },
2615
+ "access" : "readwrite",
2616
+ "description" :
2617
+ """A parameter value providing extra information for this rule's
2618
+ action. Most of the actions use the parameter value to specify
2619
+ which rule to execute after this rule's test has failed; details
2620
+ are given in the 'Traffic Flow Measurement: Architecture'
2621
+ document [RTFM-ARC].""",
2622
+ }, # column
2623
+ "flowMIBConformance" : {
2624
+ "nodetype" : "node",
2625
+ "moduleName" : "FLOW-METER-MIB",
2626
+ "oid" : "1.3.6.1.2.1.40.4",
2627
+ }, # node
2628
+ "flowMIBCompliances" : {
2629
+ "nodetype" : "node",
2630
+ "moduleName" : "FLOW-METER-MIB",
2631
+ "oid" : "1.3.6.1.2.1.40.4.1",
2632
+ }, # node
2633
+ "flowMIBGroups" : {
2634
+ "nodetype" : "node",
2635
+ "moduleName" : "FLOW-METER-MIB",
2636
+ "oid" : "1.3.6.1.2.1.40.4.2",
2637
+ }, # node
2638
+ }, # nodes
2639
+
2640
+ "groups" : {
2641
+ "flowControlGroup" : {
2642
+ "nodetype" : "group",
2643
+ "moduleName" : "FLOW-METER-MIB",
2644
+ "oid" : "1.3.6.1.2.1.40.4.2.1",
2645
+ "status" : "deprecated",
2646
+ "members" : {
2647
+ "flowRuleInfoSize" : {
2648
+ "nodetype" : "member",
2649
+ "module" : "FLOW-METER-MIB"
2650
+ },
2651
+ "flowRuleInfoOwner" : {
2652
+ "nodetype" : "member",
2653
+ "module" : "FLOW-METER-MIB"
2654
+ },
2655
+ "flowRuleInfoTimeStamp" : {
2656
+ "nodetype" : "member",
2657
+ "module" : "FLOW-METER-MIB"
2658
+ },
2659
+ "flowRuleInfoStatus" : {
2660
+ "nodetype" : "member",
2661
+ "module" : "FLOW-METER-MIB"
2662
+ },
2663
+ "flowRuleInfoName" : {
2664
+ "nodetype" : "member",
2665
+ "module" : "FLOW-METER-MIB"
2666
+ },
2667
+ "flowRuleInfoRulesReady" : {
2668
+ "nodetype" : "member",
2669
+ "module" : "FLOW-METER-MIB"
2670
+ },
2671
+ "flowRuleInfoFlowRecords" : {
2672
+ "nodetype" : "member",
2673
+ "module" : "FLOW-METER-MIB"
2674
+ },
2675
+ "flowInterfaceSampleRate" : {
2676
+ "nodetype" : "member",
2677
+ "module" : "FLOW-METER-MIB"
2678
+ },
2679
+ "flowInterfaceLostPackets" : {
2680
+ "nodetype" : "member",
2681
+ "module" : "FLOW-METER-MIB"
2682
+ },
2683
+ "flowReaderTimeout" : {
2684
+ "nodetype" : "member",
2685
+ "module" : "FLOW-METER-MIB"
2686
+ },
2687
+ "flowReaderOwner" : {
2688
+ "nodetype" : "member",
2689
+ "module" : "FLOW-METER-MIB"
2690
+ },
2691
+ "flowReaderLastTime" : {
2692
+ "nodetype" : "member",
2693
+ "module" : "FLOW-METER-MIB"
2694
+ },
2695
+ "flowReaderPreviousTime" : {
2696
+ "nodetype" : "member",
2697
+ "module" : "FLOW-METER-MIB"
2698
+ },
2699
+ "flowReaderStatus" : {
2700
+ "nodetype" : "member",
2701
+ "module" : "FLOW-METER-MIB"
2702
+ },
2703
+ "flowReaderRuleSet" : {
2704
+ "nodetype" : "member",
2705
+ "module" : "FLOW-METER-MIB"
2706
+ },
2707
+ "flowManagerCurrentRuleSet" : {
2708
+ "nodetype" : "member",
2709
+ "module" : "FLOW-METER-MIB"
2710
+ },
2711
+ "flowManagerStandbyRuleSet" : {
2712
+ "nodetype" : "member",
2713
+ "module" : "FLOW-METER-MIB"
2714
+ },
2715
+ "flowManagerHighWaterMark" : {
2716
+ "nodetype" : "member",
2717
+ "module" : "FLOW-METER-MIB"
2718
+ },
2719
+ "flowManagerCounterWrap" : {
2720
+ "nodetype" : "member",
2721
+ "module" : "FLOW-METER-MIB"
2722
+ },
2723
+ "flowManagerOwner" : {
2724
+ "nodetype" : "member",
2725
+ "module" : "FLOW-METER-MIB"
2726
+ },
2727
+ "flowManagerTimeStamp" : {
2728
+ "nodetype" : "member",
2729
+ "module" : "FLOW-METER-MIB"
2730
+ },
2731
+ "flowManagerStatus" : {
2732
+ "nodetype" : "member",
2733
+ "module" : "FLOW-METER-MIB"
2734
+ },
2735
+ "flowManagerRunningStandby" : {
2736
+ "nodetype" : "member",
2737
+ "module" : "FLOW-METER-MIB"
2738
+ },
2739
+ "flowFloodMark" : {
2740
+ "nodetype" : "member",
2741
+ "module" : "FLOW-METER-MIB"
2742
+ },
2743
+ "flowInactivityTimeout" : {
2744
+ "nodetype" : "member",
2745
+ "module" : "FLOW-METER-MIB"
2746
+ },
2747
+ "flowActiveFlows" : {
2748
+ "nodetype" : "member",
2749
+ "module" : "FLOW-METER-MIB"
2750
+ },
2751
+ "flowMaxFlows" : {
2752
+ "nodetype" : "member",
2753
+ "module" : "FLOW-METER-MIB"
2754
+ },
2755
+ "flowFloodMode" : {
2756
+ "nodetype" : "member",
2757
+ "module" : "FLOW-METER-MIB"
2758
+ },
2759
+ }, # members
2760
+ "description" :
2761
+ """The control group defines objects which are used to control
2762
+ an accounting meter.""",
2763
+ }, # group
2764
+ "flowDataTableGroup" : {
2765
+ "nodetype" : "group",
2766
+ "moduleName" : "FLOW-METER-MIB",
2767
+ "oid" : "1.3.6.1.2.1.40.4.2.2",
2768
+ "status" : "deprecated",
2769
+ "members" : {
2770
+ "flowDataStatus" : {
2771
+ "nodetype" : "member",
2772
+ "module" : "FLOW-METER-MIB"
2773
+ },
2774
+ "flowDataSourceInterface" : {
2775
+ "nodetype" : "member",
2776
+ "module" : "FLOW-METER-MIB"
2777
+ },
2778
+ "flowDataSourceAdjacentType" : {
2779
+ "nodetype" : "member",
2780
+ "module" : "FLOW-METER-MIB"
2781
+ },
2782
+ "flowDataSourceAdjacentAddress" : {
2783
+ "nodetype" : "member",
2784
+ "module" : "FLOW-METER-MIB"
2785
+ },
2786
+ "flowDataSourceAdjacentMask" : {
2787
+ "nodetype" : "member",
2788
+ "module" : "FLOW-METER-MIB"
2789
+ },
2790
+ "flowDataSourcePeerType" : {
2791
+ "nodetype" : "member",
2792
+ "module" : "FLOW-METER-MIB"
2793
+ },
2794
+ "flowDataSourcePeerAddress" : {
2795
+ "nodetype" : "member",
2796
+ "module" : "FLOW-METER-MIB"
2797
+ },
2798
+ "flowDataSourcePeerMask" : {
2799
+ "nodetype" : "member",
2800
+ "module" : "FLOW-METER-MIB"
2801
+ },
2802
+ "flowDataSourceTransType" : {
2803
+ "nodetype" : "member",
2804
+ "module" : "FLOW-METER-MIB"
2805
+ },
2806
+ "flowDataSourceTransAddress" : {
2807
+ "nodetype" : "member",
2808
+ "module" : "FLOW-METER-MIB"
2809
+ },
2810
+ "flowDataSourceTransMask" : {
2811
+ "nodetype" : "member",
2812
+ "module" : "FLOW-METER-MIB"
2813
+ },
2814
+ "flowDataDestInterface" : {
2815
+ "nodetype" : "member",
2816
+ "module" : "FLOW-METER-MIB"
2817
+ },
2818
+ "flowDataDestAdjacentType" : {
2819
+ "nodetype" : "member",
2820
+ "module" : "FLOW-METER-MIB"
2821
+ },
2822
+ "flowDataDestAdjacentAddress" : {
2823
+ "nodetype" : "member",
2824
+ "module" : "FLOW-METER-MIB"
2825
+ },
2826
+ "flowDataDestAdjacentMask" : {
2827
+ "nodetype" : "member",
2828
+ "module" : "FLOW-METER-MIB"
2829
+ },
2830
+ "flowDataDestPeerType" : {
2831
+ "nodetype" : "member",
2832
+ "module" : "FLOW-METER-MIB"
2833
+ },
2834
+ "flowDataDestPeerAddress" : {
2835
+ "nodetype" : "member",
2836
+ "module" : "FLOW-METER-MIB"
2837
+ },
2838
+ "flowDataDestPeerMask" : {
2839
+ "nodetype" : "member",
2840
+ "module" : "FLOW-METER-MIB"
2841
+ },
2842
+ "flowDataDestTransType" : {
2843
+ "nodetype" : "member",
2844
+ "module" : "FLOW-METER-MIB"
2845
+ },
2846
+ "flowDataDestTransAddress" : {
2847
+ "nodetype" : "member",
2848
+ "module" : "FLOW-METER-MIB"
2849
+ },
2850
+ "flowDataDestTransMask" : {
2851
+ "nodetype" : "member",
2852
+ "module" : "FLOW-METER-MIB"
2853
+ },
2854
+ "flowDataToOctets" : {
2855
+ "nodetype" : "member",
2856
+ "module" : "FLOW-METER-MIB"
2857
+ },
2858
+ "flowDataToPDUs" : {
2859
+ "nodetype" : "member",
2860
+ "module" : "FLOW-METER-MIB"
2861
+ },
2862
+ "flowDataFromOctets" : {
2863
+ "nodetype" : "member",
2864
+ "module" : "FLOW-METER-MIB"
2865
+ },
2866
+ "flowDataFromPDUs" : {
2867
+ "nodetype" : "member",
2868
+ "module" : "FLOW-METER-MIB"
2869
+ },
2870
+ "flowDataFirstTime" : {
2871
+ "nodetype" : "member",
2872
+ "module" : "FLOW-METER-MIB"
2873
+ },
2874
+ "flowDataLastActiveTime" : {
2875
+ "nodetype" : "member",
2876
+ "module" : "FLOW-METER-MIB"
2877
+ },
2878
+ "flowDataSourceClass" : {
2879
+ "nodetype" : "member",
2880
+ "module" : "FLOW-METER-MIB"
2881
+ },
2882
+ "flowDataDestClass" : {
2883
+ "nodetype" : "member",
2884
+ "module" : "FLOW-METER-MIB"
2885
+ },
2886
+ "flowDataClass" : {
2887
+ "nodetype" : "member",
2888
+ "module" : "FLOW-METER-MIB"
2889
+ },
2890
+ "flowDataSourceKind" : {
2891
+ "nodetype" : "member",
2892
+ "module" : "FLOW-METER-MIB"
2893
+ },
2894
+ "flowDataDestKind" : {
2895
+ "nodetype" : "member",
2896
+ "module" : "FLOW-METER-MIB"
2897
+ },
2898
+ "flowDataKind" : {
2899
+ "nodetype" : "member",
2900
+ "module" : "FLOW-METER-MIB"
2901
+ },
2902
+ }, # members
2903
+ "description" :
2904
+ """The flow table group defines objects which provide the
2905
+ structure for the flow table, including the creation time
2906
+ and activity time indexes into it. In addition it defines
2907
+ objects which provide a base set of flow attributes for the
2908
+ adjacent, peer and transport layers, together with a flow's
2909
+ counters and times. Finally it defines a flow's class and
2910
+ kind attributes, which are set by rule actions.""",
2911
+ }, # group
2912
+ "flowDataScaleGroup" : {
2913
+ "nodetype" : "group",
2914
+ "moduleName" : "FLOW-METER-MIB",
2915
+ "oid" : "1.3.6.1.2.1.40.4.2.3",
2916
+ "status" : "deprecated",
2917
+ "members" : {
2918
+ "flowManagerCounterWrap" : {
2919
+ "nodetype" : "member",
2920
+ "module" : "FLOW-METER-MIB"
2921
+ },
2922
+ "flowDataPDUScale" : {
2923
+ "nodetype" : "member",
2924
+ "module" : "FLOW-METER-MIB"
2925
+ },
2926
+ "flowDataOctetScale" : {
2927
+ "nodetype" : "member",
2928
+ "module" : "FLOW-METER-MIB"
2929
+ },
2930
+ }, # members
2931
+ "description" :
2932
+ """The flow scale group defines objects which specify scale
2933
+ factors for counters.""",
2934
+ }, # group
2935
+ "flowDataSubscriberGroup" : {
2936
+ "nodetype" : "group",
2937
+ "moduleName" : "FLOW-METER-MIB",
2938
+ "oid" : "1.3.6.1.2.1.40.4.2.4",
2939
+ "status" : "current",
2940
+ "members" : {
2941
+ "flowDataSourceSubscriberID" : {
2942
+ "nodetype" : "member",
2943
+ "module" : "FLOW-METER-MIB"
2944
+ },
2945
+ "flowDataDestSubscriberID" : {
2946
+ "nodetype" : "member",
2947
+ "module" : "FLOW-METER-MIB"
2948
+ },
2949
+ "flowDataSessionID" : {
2950
+ "nodetype" : "member",
2951
+ "module" : "FLOW-METER-MIB"
2952
+ },
2953
+ }, # members
2954
+ "description" :
2955
+ """The flow subscriber group defines objects which may be used
2956
+ to identify the end point(s) of a flow.""",
2957
+ }, # group
2958
+ "flowDataColumnTableGroup" : {
2959
+ "nodetype" : "group",
2960
+ "moduleName" : "FLOW-METER-MIB",
2961
+ "oid" : "1.3.6.1.2.1.40.4.2.5",
2962
+ "status" : "deprecated",
2963
+ "members" : {
2964
+ "flowColumnActivityAttribute" : {
2965
+ "nodetype" : "member",
2966
+ "module" : "FLOW-METER-MIB"
2967
+ },
2968
+ "flowColumnActivityIndex" : {
2969
+ "nodetype" : "member",
2970
+ "module" : "FLOW-METER-MIB"
2971
+ },
2972
+ "flowColumnActivityTime" : {
2973
+ "nodetype" : "member",
2974
+ "module" : "FLOW-METER-MIB"
2975
+ },
2976
+ "flowColumnActivityData" : {
2977
+ "nodetype" : "member",
2978
+ "module" : "FLOW-METER-MIB"
2979
+ },
2980
+ }, # members
2981
+ "description" :
2982
+ """The flow column table group defines objects which can be used
2983
+ to collect part of a column of attribute values from the flow
2984
+ table.""",
2985
+ }, # group
2986
+ "flowDataPackageGroup" : {
2987
+ "nodetype" : "group",
2988
+ "moduleName" : "FLOW-METER-MIB",
2989
+ "oid" : "1.3.6.1.2.1.40.4.2.6",
2990
+ "status" : "current",
2991
+ "members" : {
2992
+ "flowPackageData" : {
2993
+ "nodetype" : "member",
2994
+ "module" : "FLOW-METER-MIB"
2995
+ },
2996
+ }, # members
2997
+ "description" :
2998
+ """The data package group defines objects which can be used
2999
+ to collect a specified set of attribute values from a row of
3000
+ the flow table.""",
3001
+ }, # group
3002
+ "flowRuleTableGroup" : {
3003
+ "nodetype" : "group",
3004
+ "moduleName" : "FLOW-METER-MIB",
3005
+ "oid" : "1.3.6.1.2.1.40.4.2.7",
3006
+ "status" : "current",
3007
+ "members" : {
3008
+ "flowRuleSelector" : {
3009
+ "nodetype" : "member",
3010
+ "module" : "FLOW-METER-MIB"
3011
+ },
3012
+ "flowRuleMask" : {
3013
+ "nodetype" : "member",
3014
+ "module" : "FLOW-METER-MIB"
3015
+ },
3016
+ "flowRuleMatchedValue" : {
3017
+ "nodetype" : "member",
3018
+ "module" : "FLOW-METER-MIB"
3019
+ },
3020
+ "flowRuleAction" : {
3021
+ "nodetype" : "member",
3022
+ "module" : "FLOW-METER-MIB"
3023
+ },
3024
+ "flowRuleParameter" : {
3025
+ "nodetype" : "member",
3026
+ "module" : "FLOW-METER-MIB"
3027
+ },
3028
+ }, # members
3029
+ "description" :
3030
+ """The rule table group defines objects which hold the set(s)
3031
+ of rules specifying which traffic flows are to be accounted
3032
+ for.""",
3033
+ }, # group
3034
+ "flowDataScaleGroup2" : {
3035
+ "nodetype" : "group",
3036
+ "moduleName" : "FLOW-METER-MIB",
3037
+ "oid" : "1.3.6.1.2.1.40.4.2.8",
3038
+ "status" : "current",
3039
+ "members" : {
3040
+ "flowDataPDUScale" : {
3041
+ "nodetype" : "member",
3042
+ "module" : "FLOW-METER-MIB"
3043
+ },
3044
+ "flowDataOctetScale" : {
3045
+ "nodetype" : "member",
3046
+ "module" : "FLOW-METER-MIB"
3047
+ },
3048
+ }, # members
3049
+ "description" :
3050
+ """The flow scale group defines objects which specify scale
3051
+ factors for counters. This group replaces the earlier
3052
+ version of flowDataScaleGroup above (now deprecated).""",
3053
+ }, # group
3054
+ "flowControlGroup2" : {
3055
+ "nodetype" : "group",
3056
+ "moduleName" : "FLOW-METER-MIB",
3057
+ "oid" : "1.3.6.1.2.1.40.4.2.9",
3058
+ "status" : "current",
3059
+ "members" : {
3060
+ "flowRuleInfoSize" : {
3061
+ "nodetype" : "member",
3062
+ "module" : "FLOW-METER-MIB"
3063
+ },
3064
+ "flowRuleInfoOwner" : {
3065
+ "nodetype" : "member",
3066
+ "module" : "FLOW-METER-MIB"
3067
+ },
3068
+ "flowRuleInfoTimeStamp" : {
3069
+ "nodetype" : "member",
3070
+ "module" : "FLOW-METER-MIB"
3071
+ },
3072
+ "flowRuleInfoStatus" : {
3073
+ "nodetype" : "member",
3074
+ "module" : "FLOW-METER-MIB"
3075
+ },
3076
+ "flowRuleInfoName" : {
3077
+ "nodetype" : "member",
3078
+ "module" : "FLOW-METER-MIB"
3079
+ },
3080
+ "flowRuleInfoFlowRecords" : {
3081
+ "nodetype" : "member",
3082
+ "module" : "FLOW-METER-MIB"
3083
+ },
3084
+ "flowInterfaceSampleRate" : {
3085
+ "nodetype" : "member",
3086
+ "module" : "FLOW-METER-MIB"
3087
+ },
3088
+ "flowInterfaceLostPackets" : {
3089
+ "nodetype" : "member",
3090
+ "module" : "FLOW-METER-MIB"
3091
+ },
3092
+ "flowReaderTimeout" : {
3093
+ "nodetype" : "member",
3094
+ "module" : "FLOW-METER-MIB"
3095
+ },
3096
+ "flowReaderOwner" : {
3097
+ "nodetype" : "member",
3098
+ "module" : "FLOW-METER-MIB"
3099
+ },
3100
+ "flowReaderLastTime" : {
3101
+ "nodetype" : "member",
3102
+ "module" : "FLOW-METER-MIB"
3103
+ },
3104
+ "flowReaderPreviousTime" : {
3105
+ "nodetype" : "member",
3106
+ "module" : "FLOW-METER-MIB"
3107
+ },
3108
+ "flowReaderStatus" : {
3109
+ "nodetype" : "member",
3110
+ "module" : "FLOW-METER-MIB"
3111
+ },
3112
+ "flowReaderRuleSet" : {
3113
+ "nodetype" : "member",
3114
+ "module" : "FLOW-METER-MIB"
3115
+ },
3116
+ "flowManagerCurrentRuleSet" : {
3117
+ "nodetype" : "member",
3118
+ "module" : "FLOW-METER-MIB"
3119
+ },
3120
+ "flowManagerStandbyRuleSet" : {
3121
+ "nodetype" : "member",
3122
+ "module" : "FLOW-METER-MIB"
3123
+ },
3124
+ "flowManagerHighWaterMark" : {
3125
+ "nodetype" : "member",
3126
+ "module" : "FLOW-METER-MIB"
3127
+ },
3128
+ "flowManagerOwner" : {
3129
+ "nodetype" : "member",
3130
+ "module" : "FLOW-METER-MIB"
3131
+ },
3132
+ "flowManagerTimeStamp" : {
3133
+ "nodetype" : "member",
3134
+ "module" : "FLOW-METER-MIB"
3135
+ },
3136
+ "flowManagerStatus" : {
3137
+ "nodetype" : "member",
3138
+ "module" : "FLOW-METER-MIB"
3139
+ },
3140
+ "flowManagerRunningStandby" : {
3141
+ "nodetype" : "member",
3142
+ "module" : "FLOW-METER-MIB"
3143
+ },
3144
+ "flowFloodMark" : {
3145
+ "nodetype" : "member",
3146
+ "module" : "FLOW-METER-MIB"
3147
+ },
3148
+ "flowInactivityTimeout" : {
3149
+ "nodetype" : "member",
3150
+ "module" : "FLOW-METER-MIB"
3151
+ },
3152
+ "flowActiveFlows" : {
3153
+ "nodetype" : "member",
3154
+ "module" : "FLOW-METER-MIB"
3155
+ },
3156
+ "flowMaxFlows" : {
3157
+ "nodetype" : "member",
3158
+ "module" : "FLOW-METER-MIB"
3159
+ },
3160
+ "flowFloodMode" : {
3161
+ "nodetype" : "member",
3162
+ "module" : "FLOW-METER-MIB"
3163
+ },
3164
+ }, # members
3165
+ "description" :
3166
+ """The control group defines objects which are used to control
3167
+ an accounting meter. It replaces the earlier version of
3168
+ flowControlGroup above (now deprecated).""",
3169
+ }, # group
3170
+ }, # groups
3171
+
3172
+ "compliances" : {
3173
+ "flowMIBCompliance" : {
3174
+ "nodetype" : "compliance",
3175
+ "moduleName" : "FLOW-METER-MIB",
3176
+ "oid" : "1.3.6.1.2.1.40.4.1.1",
3177
+ "status" : "current",
3178
+ "description" :
3179
+ """The compliance statement for a Traffic Flow Meter.""",
3180
+ "requires" : {
3181
+ "flowControlGroup2" : {
3182
+ "nodetype" : "mandatory",
3183
+ "module" : "FLOW-METER-MIB"
3184
+ },
3185
+ "flowDataTableGroup" : {
3186
+ "nodetype" : "mandatory",
3187
+ "module" : "FLOW-METER-MIB"
3188
+ },
3189
+ "flowDataPackageGroup" : {
3190
+ "nodetype" : "mandatory",
3191
+ "module" : "FLOW-METER-MIB"
3192
+ },
3193
+ "flowRuleTableGroup" : {
3194
+ "nodetype" : "mandatory",
3195
+ "module" : "FLOW-METER-MIB"
3196
+ },
3197
+ }, # requires
3198
+ }, # compliance
3199
+ }, # compliances
3200
+
3201
+ }