logstash-input-snmp 0.1.0.beta4 → 0.1.0.beta5

Sign up to get free protection for your applications and to get access to all the features.
Files changed (309) hide show
  1. checksums.yaml +4 -4
  2. data/CHANGELOG.md +5 -0
  3. data/lib/logstash/inputs/snmp.rb +75 -12
  4. data/lib/logstash/inputs/snmp/base_client.rb +162 -0
  5. data/lib/logstash/inputs/snmp/client.rb +11 -109
  6. data/lib/logstash/inputs/snmp/clientv3.rb +139 -0
  7. data/lib/logstash/inputs/snmp/mib.rb +22 -20
  8. data/lib/mibs/ietf/ACCOUNTING-CONTROL-MIB.dic +1316 -0
  9. data/lib/mibs/ietf/ADSL-LINE-EXT-MIB.dic +1724 -0
  10. data/lib/mibs/ietf/ADSL-LINE-MIB.dic +7297 -0
  11. data/lib/mibs/ietf/ADSL-TC-MIB.dic +160 -0
  12. data/lib/mibs/ietf/ADSL2-LINE-MIB.dic +8663 -0
  13. data/lib/mibs/ietf/ADSL2-LINE-TC-MIB.dic +1462 -0
  14. data/lib/mibs/ietf/AGENTX-MIB.dic +817 -0
  15. data/lib/mibs/ietf/AGGREGATE-MIB.dic +708 -0
  16. data/lib/mibs/ietf/ALARM-MIB.dic +1734 -0
  17. data/lib/mibs/ietf/APM-MIB.dic +2870 -0
  18. data/lib/mibs/ietf/APPC-MIB.dic +8687 -0
  19. data/lib/mibs/ietf/APPLETALK-MIB.dic +4399 -0
  20. data/lib/mibs/ietf/APPLICATION-MIB.dic +3750 -0
  21. data/lib/mibs/ietf/APPN-DLUR-MIB.dic +972 -0
  22. data/lib/mibs/ietf/APPN-MIB.dic +9364 -0
  23. data/lib/mibs/ietf/APPN-TRAP-MIB.dic +664 -0
  24. data/lib/mibs/ietf/APS-MIB.dic +2430 -0
  25. data/lib/mibs/ietf/ARC-MIB.dic +552 -0
  26. data/lib/mibs/ietf/ATM-ACCOUNTING-INFORMATION-MIB.dic +816 -0
  27. data/lib/mibs/ietf/ATM-MIB.dic +4104 -0
  28. data/lib/mibs/ietf/ATM-TC-MIB.dic +914 -0
  29. data/lib/mibs/ietf/ATM2-MIB.dic +4715 -0
  30. data/lib/mibs/ietf/BFD-STD-MIB.dic +2367 -0
  31. data/lib/mibs/ietf/BFD-TC-STD-MIB.dic +202 -0
  32. data/lib/mibs/ietf/BGP4-MIB.dic +1931 -0
  33. data/lib/mibs/ietf/BLDG-HVAC-MIB.dic +812 -0
  34. data/lib/mibs/ietf/BRIDGE-MIB.dic +2257 -0
  35. data/lib/mibs/ietf/CAPWAP-BASE-MIB.dic +4128 -0
  36. data/lib/mibs/ietf/CAPWAP-DOT11-MIB.dic +482 -0
  37. data/lib/mibs/ietf/CHARACTER-MIB.dic +1140 -0
  38. data/lib/mibs/ietf/CIRCUIT-IF-MIB.dic +493 -0
  39. data/lib/mibs/ietf/CLNS-MIB.dic +1702 -0
  40. data/lib/mibs/ietf/COFFEE-POT-MIB.dic +282 -0
  41. data/lib/mibs/ietf/COPS-CLIENT-MIB.dic +1270 -0
  42. data/lib/mibs/ietf/DECNET-PHIV-MIB.dic +5837 -0
  43. data/lib/mibs/ietf/DIAL-CONTROL-MIB.dic +2139 -0
  44. data/lib/mibs/ietf/DIFFSERV-CONFIG-MIB.dic +378 -0
  45. data/lib/mibs/ietf/DIFFSERV-MIB.dic +5073 -0
  46. data/lib/mibs/ietf/DIRECTORY-SERVER-MIB.dic +1041 -0
  47. data/lib/mibs/ietf/DISMAN-EVENT-MIB.dic +3151 -0
  48. data/lib/mibs/ietf/DISMAN-EXPRESSION-MIB.dic +1716 -0
  49. data/lib/mibs/ietf/DISMAN-NSLOOKUP-MIB.dic +698 -0
  50. data/lib/mibs/ietf/DISMAN-PING-MIB.dic +2635 -0
  51. data/lib/mibs/ietf/DISMAN-SCHEDULE-MIB.dic +1744 -0
  52. data/lib/mibs/ietf/DISMAN-SCRIPT-MIB.dic +2820 -0
  53. data/lib/mibs/ietf/DISMAN-TRACEROUTE-MIB.dic +3239 -0
  54. data/lib/mibs/ietf/DLSW-MIB.dic +5635 -0
  55. data/lib/mibs/ietf/DNS-RESOLVER-MIB.dic +1765 -0
  56. data/lib/mibs/ietf/DNS-SERVER-MIB.dic +1593 -0
  57. data/lib/mibs/ietf/DOCS-BPI-MIB.dic +2634 -0
  58. data/lib/mibs/ietf/DOCS-CABLE-DEVICE-MIB.dic +5042 -0
  59. data/lib/mibs/ietf/DOCS-IETF-BPI2-MIB.dic +5478 -0
  60. data/lib/mibs/ietf/DOCS-IETF-CABLE-DEVICE-NOTIFICATION-MIB.dic +2447 -0
  61. data/lib/mibs/ietf/DOCS-IETF-QOS-MIB.dic +4886 -0
  62. data/lib/mibs/ietf/DOCS-IETF-SUBMGT-MIB.dic +1331 -0
  63. data/lib/mibs/ietf/DOCS-IF-MIB.dic +7980 -0
  64. data/lib/mibs/ietf/DOT12-IF-MIB.dic +1066 -0
  65. data/lib/mibs/ietf/DOT12-RPTR-MIB.dic +2669 -0
  66. data/lib/mibs/ietf/DOT3-EPON-MIB.dic +3297 -0
  67. data/lib/mibs/ietf/DOT3-OAM-MIB.dic +2830 -0
  68. data/lib/mibs/ietf/DS0-MIB.dic +466 -0
  69. data/lib/mibs/ietf/DS0BUNDLE-MIB.dic +468 -0
  70. data/lib/mibs/ietf/DS1-MIB.dic +4890 -0
  71. data/lib/mibs/ietf/DS3-MIB.dic +2719 -0
  72. data/lib/mibs/ietf/DSA-MIB.dic +888 -0
  73. data/lib/mibs/ietf/DSMON-MIB.dic +6177 -0
  74. data/lib/mibs/ietf/DVB-RCS-MIB.dic +5764 -0
  75. data/lib/mibs/ietf/EBN-MIB.dic +1026 -0
  76. data/lib/mibs/ietf/EFM-CU-MIB.dic +4335 -0
  77. data/lib/mibs/ietf/ENTITY-MIB.dic +2235 -0
  78. data/lib/mibs/ietf/ENTITY-SENSOR-MIB.dic +653 -0
  79. data/lib/mibs/ietf/ENTITY-STATE-MIB.dic +457 -0
  80. data/lib/mibs/ietf/ENTITY-STATE-TC-MIB.dic +260 -0
  81. data/lib/mibs/ietf/ETHER-CHIPSET-MIB.dic +787 -0
  82. data/lib/mibs/ietf/EtherLike-MIB.dic +2548 -0
  83. data/lib/mibs/ietf/FC-MGMT-MIB.dic +3465 -0
  84. data/lib/mibs/ietf/FCIP-MGMT-MIB.dic +1596 -0
  85. data/lib/mibs/ietf/FDDI-SMT73-MIB.dic +3378 -0
  86. data/lib/mibs/ietf/FIBRE-CHANNEL-FE-MIB.dic +2504 -0
  87. data/lib/mibs/ietf/FLOAT-TC-MIB.dic +128 -0
  88. data/lib/mibs/ietf/FLOW-METER-MIB.dic +3201 -0
  89. data/lib/mibs/ietf/FORCES-MIB.dic +598 -0
  90. data/lib/mibs/ietf/FR-ATM-PVC-SERVICE-IWF-MIB.dic +1601 -0
  91. data/lib/mibs/ietf/FR-MFR-MIB.dic +1351 -0
  92. data/lib/mibs/ietf/FRAME-RELAY-DTE-MIB.dic +1688 -0
  93. data/lib/mibs/ietf/FRNETSERV-MIB.dic +3940 -0
  94. data/lib/mibs/ietf/FRSLD-MIB.dic +2580 -0
  95. data/lib/mibs/ietf/Finisher-MIB.dic +1416 -0
  96. data/lib/mibs/ietf/GMPLS-LABEL-STD-MIB.dic +965 -0
  97. data/lib/mibs/ietf/GMPLS-LSR-STD-MIB.dic +693 -0
  98. data/lib/mibs/ietf/GMPLS-TC-STD-MIB.dic +180 -0
  99. data/lib/mibs/ietf/GMPLS-TE-STD-MIB.dic +2542 -0
  100. data/lib/mibs/ietf/GSMP-MIB.dic +2468 -0
  101. data/lib/mibs/ietf/HC-ALARM-MIB.dic +1050 -0
  102. data/lib/mibs/ietf/HC-PerfHist-TC-MIB.dic +310 -0
  103. data/lib/mibs/ietf/HC-RMON-MIB.dic +4456 -0
  104. data/lib/mibs/ietf/HDSL2-SHDSL-LINE-MIB.dic +3955 -0
  105. data/lib/mibs/ietf/HOST-RESOURCES-MIB.dic +2453 -0
  106. data/lib/mibs/ietf/HPR-IP-MIB.dic +640 -0
  107. data/lib/mibs/ietf/HPR-MIB.dic +1959 -0
  108. data/lib/mibs/ietf/IANA-ITU-ALARM-TC-MIB.dic +936 -0
  109. data/lib/mibs/ietf/IF-CAP-STACK-MIB.dic +356 -0
  110. data/lib/mibs/ietf/IF-INVERTED-STACK-MIB.dic +220 -0
  111. data/lib/mibs/ietf/IF-MIB.dic +2753 -0
  112. data/lib/mibs/ietf/IFCP-MGMT-MIB.dic +1717 -0
  113. data/lib/mibs/ietf/IGMP-STD-MIB.dic +809 -0
  114. data/lib/mibs/ietf/INET-ADDRESS-MIB.dic +570 -0
  115. data/lib/mibs/ietf/INTEGRATED-SERVICES-GUARANTEED-MIB.dic +319 -0
  116. data/lib/mibs/ietf/INTEGRATED-SERVICES-MIB.dic +1196 -0
  117. data/lib/mibs/ietf/INTERFACETOPN-MIB.dic +1705 -0
  118. data/lib/mibs/ietf/IP-FORWARD-MIB.dic +1853 -0
  119. data/lib/mibs/ietf/IP-MIB.dic +7064 -0
  120. data/lib/mibs/ietf/IPATM-IPMC-MIB.dic +4830 -0
  121. data/lib/mibs/ietf/IPFIX-MIB.dic +2334 -0
  122. data/lib/mibs/ietf/IPFIX-SELECTOR-MIB.dic +215 -0
  123. data/lib/mibs/ietf/IPMCAST-MIB.dic +3390 -0
  124. data/lib/mibs/ietf/IPMROUTE-STD-MIB.dic +1246 -0
  125. data/lib/mibs/ietf/IPOA-MIB.dic +2372 -0
  126. data/lib/mibs/ietf/IPS-AUTH-MIB.dic +1609 -0
  127. data/lib/mibs/ietf/IPSEC-SPD-MIB.dic +3989 -0
  128. data/lib/mibs/ietf/IPV6-FLOW-LABEL-MIB.dic +110 -0
  129. data/lib/mibs/ietf/IPV6-ICMP-MIB.dic +748 -0
  130. data/lib/mibs/ietf/IPV6-MIB.dic +2028 -0
  131. data/lib/mibs/ietf/IPV6-MLD-MIB.dic +659 -0
  132. data/lib/mibs/ietf/IPV6-TCP-MIB.dic +332 -0
  133. data/lib/mibs/ietf/IPV6-UDP-MIB.dic +209 -0
  134. data/lib/mibs/ietf/ISCSI-MIB.dic +4613 -0
  135. data/lib/mibs/ietf/ISDN-MIB.dic +1796 -0
  136. data/lib/mibs/ietf/ISIS-MIB.dic +6215 -0
  137. data/lib/mibs/ietf/ISNS-MIB.dic +6578 -0
  138. data/lib/mibs/ietf/ITU-ALARM-MIB.dic +665 -0
  139. data/lib/mibs/ietf/ITU-ALARM-TC-MIB.dic +137 -0
  140. data/lib/mibs/ietf/Job-Monitoring-MIB.dic +2519 -0
  141. data/lib/mibs/ietf/L2TP-MIB.dic +4050 -0
  142. data/lib/mibs/ietf/LANGTAG-TC-MIB.dic +104 -0
  143. data/lib/mibs/ietf/LISP-MIB.dic +4067 -0
  144. data/lib/mibs/ietf/LMP-MIB.dic +5166 -0
  145. data/lib/mibs/ietf/MALLOC-MIB.dic +2156 -0
  146. data/lib/mibs/ietf/MAU-MIB.dic +2619 -0
  147. data/lib/mibs/ietf/MIDCOM-MIB.dic +2856 -0
  148. data/lib/mibs/ietf/MIOX25-MIB.dic +828 -0
  149. data/lib/mibs/ietf/MIP-MIB.dic +3473 -0
  150. data/lib/mibs/ietf/MOBILEIPV6-MIB.dic +5228 -0
  151. data/lib/mibs/ietf/MPLS-FTN-STD-MIB.dic +1594 -0
  152. data/lib/mibs/ietf/MPLS-L3VPN-STD-MIB.dic +2548 -0
  153. data/lib/mibs/ietf/MPLS-LC-ATM-STD-MIB.dic +491 -0
  154. data/lib/mibs/ietf/MPLS-LC-FR-STD-MIB.dic +395 -0
  155. data/lib/mibs/ietf/MPLS-LDP-ATM-STD-MIB.dic +1019 -0
  156. data/lib/mibs/ietf/MPLS-LDP-FRAME-RELAY-STD-MIB.dic +862 -0
  157. data/lib/mibs/ietf/MPLS-LDP-GENERIC-STD-MIB.dic +445 -0
  158. data/lib/mibs/ietf/MPLS-LDP-STD-MIB.dic +3657 -0
  159. data/lib/mibs/ietf/MPLS-LSR-STD-MIB.dic +3103 -0
  160. data/lib/mibs/ietf/MPLS-TC-STD-MIB.dic +911 -0
  161. data/lib/mibs/ietf/MPLS-TE-STD-MIB.dic +3673 -0
  162. data/lib/mibs/ietf/MSDP-MIB.dic +1893 -0
  163. data/lib/mibs/ietf/MTA-MIB.dic +1898 -0
  164. data/lib/mibs/ietf/Modem-MIB.dic +2054 -0
  165. data/lib/mibs/ietf/NAT-MIB.dic +3866 -0
  166. data/lib/mibs/ietf/NETWORK-SERVICES-MIB.dic +1034 -0
  167. data/lib/mibs/ietf/NHDP-MIB.dic +3005 -0
  168. data/lib/mibs/ietf/NHRP-MIB.dic +3660 -0
  169. data/lib/mibs/ietf/NOTIFICATION-LOG-MIB.dic +1156 -0
  170. data/lib/mibs/ietf/NTPv4-MIB.dic +1535 -0
  171. data/lib/mibs/ietf/OPT-IF-MIB.dic +8972 -0
  172. data/lib/mibs/ietf/OSPF-MIB.dic +5963 -0
  173. data/lib/mibs/ietf/OSPF-TRAP-MIB.dic +1190 -0
  174. data/lib/mibs/ietf/OSPFV3-MIB.dic +5708 -0
  175. data/lib/mibs/ietf/P-BRIDGE-MIB.dic +1499 -0
  176. data/lib/mibs/ietf/PARALLEL-MIB.dic +476 -0
  177. data/lib/mibs/ietf/PIM-MIB.dic +1393 -0
  178. data/lib/mibs/ietf/PIM-STD-MIB.dic +6819 -0
  179. data/lib/mibs/ietf/PINT-MIB.dic +830 -0
  180. data/lib/mibs/ietf/PKTC-IETF-MTA-MIB.dic +3191 -0
  181. data/lib/mibs/ietf/PKTC-IETF-SIG-MIB.dic +4713 -0
  182. data/lib/mibs/ietf/PMIPV6-MIB.dic +3010 -0
  183. data/lib/mibs/ietf/PMIPV6-TC-MIB.dic +293 -0
  184. data/lib/mibs/ietf/POLICY-BASED-MANAGEMENT-MIB.dic +3316 -0
  185. data/lib/mibs/ietf/POWER-ETHERNET-MIB.dic +959 -0
  186. data/lib/mibs/ietf/PPP-BRIDGE-NCP-MIB.dic +587 -0
  187. data/lib/mibs/ietf/PPP-IP-NCP-MIB.dic +269 -0
  188. data/lib/mibs/ietf/PPP-LCP-MIB.dic +994 -0
  189. data/lib/mibs/ietf/PPP-SEC-MIB.dic +411 -0
  190. data/lib/mibs/ietf/PSAMP-MIB.dic +998 -0
  191. data/lib/mibs/ietf/PTOPO-MIB.dic +1135 -0
  192. data/lib/mibs/ietf/PW-ATM-MIB.dic +1642 -0
  193. data/lib/mibs/ietf/PW-CEP-STD-MIB.dic +3661 -0
  194. data/lib/mibs/ietf/PW-STD-MIB.dic +3592 -0
  195. data/lib/mibs/ietf/PW-TC-STD-MIB.dic +437 -0
  196. data/lib/mibs/ietf/PW-TDM-MIB.dic +1896 -0
  197. data/lib/mibs/ietf/PerfHist-TC-MIB.dic +152 -0
  198. data/lib/mibs/ietf/Printer-MIB.dic +6665 -0
  199. data/lib/mibs/ietf/Q-BRIDGE-MIB.dic +3115 -0
  200. data/lib/mibs/ietf/RADIUS-ACC-CLIENT-MIB.dic +991 -0
  201. data/lib/mibs/ietf/RADIUS-ACC-SERVER-MIB.dic +1183 -0
  202. data/lib/mibs/ietf/RADIUS-AUTH-CLIENT-MIB.dic +1073 -0
  203. data/lib/mibs/ietf/RADIUS-AUTH-SERVER-MIB.dic +1251 -0
  204. data/lib/mibs/ietf/RADIUS-DYNAUTH-CLIENT-MIB.dic +1116 -0
  205. data/lib/mibs/ietf/RADIUS-DYNAUTH-SERVER-MIB.dic +1003 -0
  206. data/lib/mibs/ietf/RAQMON-MIB.dic +2695 -0
  207. data/lib/mibs/ietf/RBRIDGE-MIB.dic +2981 -0
  208. data/lib/mibs/ietf/RDBMS-MIB.dic +1935 -0
  209. data/lib/mibs/ietf/RFC1065-SMI.dic +108 -0
  210. data/lib/mibs/ietf/RFC1155-SMI.dic +118 -0
  211. data/lib/mibs/ietf/RFC1158-MIB.dic +2440 -0
  212. data/lib/mibs/ietf/RFC1213-MIB.dic +3434 -0
  213. data/lib/mibs/ietf/RFC1269-MIB.dic +557 -0
  214. data/lib/mibs/ietf/RFC1271-MIB.dic +4135 -0
  215. data/lib/mibs/ietf/RFC1285-MIB.dic +2842 -0
  216. data/lib/mibs/ietf/RFC1316-MIB.dic +800 -0
  217. data/lib/mibs/ietf/RFC1381-MIB.dic +1347 -0
  218. data/lib/mibs/ietf/RFC1382-MIB.dic +3820 -0
  219. data/lib/mibs/ietf/RFC1414-MIB.dic +214 -0
  220. data/lib/mibs/ietf/RIPv2-MIB.dic +773 -0
  221. data/lib/mibs/ietf/RMON-MIB.dic +5551 -0
  222. data/lib/mibs/ietf/RMON2-MIB.dic +8224 -0
  223. data/lib/mibs/ietf/ROHC-MIB.dic +1613 -0
  224. data/lib/mibs/ietf/ROHC-RTP-MIB.dic +859 -0
  225. data/lib/mibs/ietf/ROHC-UNCOMPRESSED-MIB.dic +267 -0
  226. data/lib/mibs/ietf/RPKI-ROUTER-MIB.dic +1363 -0
  227. data/lib/mibs/ietf/RS-232-MIB.dic +1335 -0
  228. data/lib/mibs/ietf/RSERPOOL-MIB.dic +2501 -0
  229. data/lib/mibs/ietf/RSTP-MIB.dic +427 -0
  230. data/lib/mibs/ietf/RSVP-MIB.dic +4135 -0
  231. data/lib/mibs/ietf/RTP-MIB.dic +1376 -0
  232. data/lib/mibs/ietf/SCSI-MIB.dic +3804 -0
  233. data/lib/mibs/ietf/SCTP-MIB.dic +1924 -0
  234. data/lib/mibs/ietf/SFLOW-MIB.dic +568 -0
  235. data/lib/mibs/ietf/SIP-COMMON-MIB.dic +2769 -0
  236. data/lib/mibs/ietf/SIP-MIB.dic +1438 -0
  237. data/lib/mibs/ietf/SIP-SERVER-MIB.dic +1150 -0
  238. data/lib/mibs/ietf/SIP-TC-MIB.dic +257 -0
  239. data/lib/mibs/ietf/SIP-UA-MIB.dic +268 -0
  240. data/lib/mibs/ietf/SLAPM-MIB.dic +4527 -0
  241. data/lib/mibs/ietf/SMON-MIB.dic +1758 -0
  242. data/lib/mibs/ietf/SNA-NAU-MIB.dic +4042 -0
  243. data/lib/mibs/ietf/SNA-SDLC-MIB.dic +3858 -0
  244. data/lib/mibs/ietf/SNMP-COMMUNITY-MIB.dic +715 -0
  245. data/lib/mibs/ietf/SNMP-FRAMEWORK-MIB.dic +709 -0
  246. data/lib/mibs/ietf/SNMP-MPD-MIB.dic +230 -0
  247. data/lib/mibs/ietf/SNMP-NOTIFICATION-MIB.dic +859 -0
  248. data/lib/mibs/ietf/SNMP-PROXY-MIB.dic +414 -0
  249. data/lib/mibs/ietf/SNMP-REPEATER-MIB.dic +4335 -0
  250. data/lib/mibs/ietf/SNMP-SSH-TM-MIB.dic +447 -0
  251. data/lib/mibs/ietf/SNMP-TARGET-MIB.dic +924 -0
  252. data/lib/mibs/ietf/SNMP-TLS-TM-MIB.dic +1449 -0
  253. data/lib/mibs/ietf/SNMP-TSM-MIB.dic +315 -0
  254. data/lib/mibs/ietf/SNMP-USER-BASED-SM-MIB.dic +1164 -0
  255. data/lib/mibs/ietf/SNMP-USM-AES-MIB.dic +95 -0
  256. data/lib/mibs/ietf/SNMP-USM-DH-OBJECTS-MIB.dic +653 -0
  257. data/lib/mibs/ietf/SNMP-VIEW-BASED-ACM-MIB.dic +1202 -0
  258. data/lib/mibs/ietf/SNMPv2-MIB.dic +1382 -0
  259. data/lib/mibs/ietf/SNMPv2-SMI.dic +223 -0
  260. data/lib/mibs/ietf/SNMPv2-USEC-MIB.dic +405 -0
  261. data/lib/mibs/ietf/SONET-MIB.dic +3308 -0
  262. data/lib/mibs/ietf/SOURCE-ROUTING-MIB.dic +542 -0
  263. data/lib/mibs/ietf/SSPM-MIB.dic +1530 -0
  264. data/lib/mibs/ietf/SYSAPPL-MIB.dic +2092 -0
  265. data/lib/mibs/ietf/T11-FC-FABRIC-ADDR-MGR-MIB.dic +1779 -0
  266. data/lib/mibs/ietf/T11-FC-FABRIC-CONFIG-SERVER-MIB.dic +2822 -0
  267. data/lib/mibs/ietf/T11-FC-FABRIC-LOCK-MIB.dic +700 -0
  268. data/lib/mibs/ietf/T11-FC-FSPF-MIB.dic +1889 -0
  269. data/lib/mibs/ietf/T11-FC-NAME-SERVER-MIB.dic +1775 -0
  270. data/lib/mibs/ietf/T11-FC-ROUTE-MIB.dic +655 -0
  271. data/lib/mibs/ietf/T11-FC-RSCN-MIB.dic +1110 -0
  272. data/lib/mibs/ietf/T11-FC-VIRTUAL-FABRIC-MIB.dic +770 -0
  273. data/lib/mibs/ietf/T11-FC-ZONE-SERVER-MIB.dic +3886 -0
  274. data/lib/mibs/ietf/T11-TC-MIB.dic +110 -0
  275. data/lib/mibs/ietf/TCP-ESTATS-MIB.dic +3926 -0
  276. data/lib/mibs/ietf/TCP-MIB.dic +1319 -0
  277. data/lib/mibs/ietf/TCPIPX-MIB.dic +457 -0
  278. data/lib/mibs/ietf/TE-LINK-STD-MIB.dic +2876 -0
  279. data/lib/mibs/ietf/TE-MIB.dic +2924 -0
  280. data/lib/mibs/ietf/TED-MIB.dic +1749 -0
  281. data/lib/mibs/ietf/TIME-AGGREGATE-MIB.dic +550 -0
  282. data/lib/mibs/ietf/TN3270E-MIB.dic +2785 -0
  283. data/lib/mibs/ietf/TN3270E-RT-MIB.dic +1317 -0
  284. data/lib/mibs/ietf/TOKEN-RING-RMON-MIB.dic +2820 -0
  285. data/lib/mibs/ietf/TOKENRING-MIB.dic +1184 -0
  286. data/lib/mibs/ietf/TOKENRING-STATION-SR-MIB.dic +292 -0
  287. data/lib/mibs/ietf/TRANSPORT-ADDRESS-MIB.dic +610 -0
  288. data/lib/mibs/ietf/TRIP-MIB.dic +3159 -0
  289. data/lib/mibs/ietf/TRIP-TC-MIB.dic +241 -0
  290. data/lib/mibs/ietf/TUNNEL-MIB.dic +1095 -0
  291. data/lib/mibs/ietf/UDP-MIB.dic +751 -0
  292. data/lib/mibs/ietf/UDPLITE-MIB.dic +704 -0
  293. data/lib/mibs/ietf/UPS-MIB.dic +3088 -0
  294. data/lib/mibs/ietf/URI-TC-MIB.dic +193 -0
  295. data/lib/mibs/ietf/UUID-TC-MIB.dic +135 -0
  296. data/lib/mibs/ietf/VDSL-LINE-EXT-MCM-MIB.dic +989 -0
  297. data/lib/mibs/ietf/VDSL-LINE-EXT-SCM-MIB.dic +605 -0
  298. data/lib/mibs/ietf/VDSL-LINE-MIB.dic +4518 -0
  299. data/lib/mibs/ietf/VDSL2-LINE-MIB.dic +11029 -0
  300. data/lib/mibs/ietf/VDSL2-LINE-TC-MIB.dic +3152 -0
  301. data/lib/mibs/ietf/VPN-TC-STD-MIB.dic +121 -0
  302. data/lib/mibs/ietf/VRRP-MIB.dic +1163 -0
  303. data/lib/mibs/ietf/VRRPV3-MIB.dic +1403 -0
  304. data/lib/mibs/ietf/WWW-MIB.dic +1810 -0
  305. data/lib/mibs/logstash/iso.dic +18 -0
  306. data/logstash-input-snmp.gemspec +1 -1
  307. data/spec/inputs/snmp/mib_spec.rb +10 -17
  308. data/spec/inputs/snmp_spec.rb +27 -1
  309. metadata +302 -2
@@ -0,0 +1,2548 @@
1
+ # python version 1.0 DO NOT EDIT
2
+ #
3
+ # This python file has been generated by smidump version 0.5.0:
4
+ #
5
+ # smidump -f python EtherLike-MIB
6
+
7
+ FILENAME = "./libsmi-0.5.0/mibs/ietf/EtherLike-MIB"
8
+
9
+ MIB = {
10
+ "moduleName" : "EtherLike-MIB",
11
+
12
+ "EtherLike-MIB" : {
13
+ "nodetype" : "module",
14
+ "language" : "SMIv2",
15
+ "organization" :
16
+ """IETF Ethernet Interfaces and Hub MIB
17
+ Working Group""",
18
+ "contact" :
19
+ """WG E-mail: hubmib@ietf.org
20
+ To subscribe: hubmib-request@ietf.org
21
+
22
+ Chair: Dan Romascanu
23
+ Postal: Avaya Inc.
24
+ Atidum Technology Park, Bldg. 3
25
+ Tel Aviv 61131
26
+ Israel
27
+ Tel: +972 3 645 8414
28
+ E-mail: dromasca@avaya.com
29
+
30
+ Editor: John Flick
31
+ Postal: Hewlett-Packard Company
32
+ 8000 Foothills Blvd. M/S 5557
33
+ Roseville, CA 95747-5557
34
+ USA
35
+ Tel: +1 916 785 4018
36
+ Fax: +1 916 785 1199
37
+ E-mail: johnf@rose.hp.com""",
38
+ "description" :
39
+ """The MIB module to describe generic objects for
40
+ ethernet-like network interfaces.
41
+
42
+ The following reference is used throughout this
43
+ MIB module:
44
+
45
+ [IEEE 802.3 Std] refers to:
46
+ IEEE Std 802.3, 2002 Edition: 'IEEE Standard
47
+
48
+
49
+
50
+ for Information technology -
51
+ Telecommunications and information exchange
52
+ between systems - Local and metropolitan
53
+ area networks - Specific requirements -
54
+ Part 3: Carrier sense multiple access with
55
+ collision detection (CSMA/CD) access method
56
+ and physical layer specifications', as
57
+ amended by IEEE Std 802.3ae-2002:
58
+ 'Amendment: Media Access Control (MAC)
59
+ Parameters, Physical Layer, and Management
60
+ Parameters for 10 Gb/s Operation', August,
61
+ 2002.
62
+
63
+ Of particular interest is Clause 30, '10 Mb/s,
64
+ 100 Mb/s, 1000 Mb/s, and 10 Gb/s Management'.
65
+
66
+ Copyright (C) The Internet Society (2003). This
67
+ version of this MIB module is part of RFC 3635;
68
+ see the RFC itself for full legal notices.""",
69
+ "revisions" : (
70
+ {
71
+ "date" : "2003-09-19 00:00",
72
+ "description" :
73
+ """Updated to include support for 10 Gb/sec
74
+ interfaces. This resulted in the following
75
+ revisions:
76
+
77
+ - Updated dot3StatsAlignmentErrors and
78
+ dot3StatsSymbolErrors DESCRIPTIONs to
79
+ reflect behaviour at 10 Gb/s
80
+ - Added dot3StatsRateControlAbility and
81
+ dot3RateControlStatus for management
82
+ of the Rate Control function in 10 Gb/s
83
+ WAN applications
84
+ - Added 64-bit versions of all counters
85
+ that are used on high-speed ethernet
86
+ interfaces
87
+ - Added object groups to contain the new
88
+ objects
89
+ - Deprecated etherStatsBaseGroup and
90
+ split into etherStatsBaseGroup2 and
91
+ etherStatsHalfDuplexGroup, so that
92
+ interfaces which can only operate at
93
+ full-duplex do not need to implement
94
+ half-duplex-only statistics
95
+ - Deprecated dot3Compliance and replaced
96
+ it with dot3Compliance2, which includes
97
+ the compliance information for the new
98
+ object groups
99
+
100
+
101
+
102
+
103
+ In addition, the dot3Tests and dot3Errors
104
+ object identities have been deprecated,
105
+ since there is no longer a standard method
106
+ for using them.
107
+
108
+ This version published as RFC 3635.""",
109
+ },
110
+ {
111
+ "date" : "1999-08-24 04:00",
112
+ "description" :
113
+ """Updated to include support for 1000 Mb/sec
114
+ interfaces and full-duplex interfaces.
115
+ This version published as RFC 2665.""",
116
+ },
117
+ {
118
+ "date" : "1998-06-03 21:50",
119
+ "description" :
120
+ """Updated to include support for 100 Mb/sec
121
+ interfaces.
122
+ This version published as RFC 2358.""",
123
+ },
124
+ {
125
+ "date" : "1994-02-03 04:00",
126
+ "description" :
127
+ """Initial version, published as RFC 1650.""",
128
+ },
129
+ ),
130
+ "identity node" : "etherMIB",
131
+ },
132
+
133
+ "imports" : (
134
+ {"module" : "SNMPv2-SMI", "name" : "MODULE-IDENTITY"},
135
+ {"module" : "SNMPv2-SMI", "name" : "OBJECT-TYPE"},
136
+ {"module" : "SNMPv2-SMI", "name" : "OBJECT-IDENTITY"},
137
+ {"module" : "SNMPv2-SMI", "name" : "Integer32"},
138
+ {"module" : "SNMPv2-SMI", "name" : "Counter32"},
139
+ {"module" : "SNMPv2-SMI", "name" : "Counter64"},
140
+ {"module" : "SNMPv2-SMI", "name" : "mib-2"},
141
+ {"module" : "SNMPv2-SMI", "name" : "transmission"},
142
+ {"module" : "SNMPv2-CONF", "name" : "MODULE-COMPLIANCE"},
143
+ {"module" : "SNMPv2-CONF", "name" : "OBJECT-GROUP"},
144
+ {"module" : "SNMPv2-TC", "name" : "TruthValue"},
145
+ {"module" : "IF-MIB", "name" : "ifIndex"},
146
+ {"module" : "IF-MIB", "name" : "InterfaceIndex"},
147
+ ),
148
+
149
+ "nodes" : {
150
+ "dot3" : {
151
+ "nodetype" : "node",
152
+ "moduleName" : "EtherLike-MIB",
153
+ "oid" : "1.3.6.1.2.1.10.7",
154
+ }, # node
155
+ "dot3StatsTable" : {
156
+ "nodetype" : "table",
157
+ "moduleName" : "EtherLike-MIB",
158
+ "oid" : "1.3.6.1.2.1.10.7.2",
159
+ "status" : "current",
160
+ "description" :
161
+ """Statistics for a collection of ethernet-like
162
+ interfaces attached to a particular system.
163
+ There will be one row in this table for each
164
+ ethernet-like interface in the system.""",
165
+ }, # table
166
+ "dot3StatsEntry" : {
167
+ "nodetype" : "row",
168
+ "moduleName" : "EtherLike-MIB",
169
+ "oid" : "1.3.6.1.2.1.10.7.2.1",
170
+ "status" : "current",
171
+ "linkage" : [
172
+ "dot3StatsIndex",
173
+ ],
174
+ "description" :
175
+ """Statistics for a particular interface to an
176
+ ethernet-like medium.""",
177
+ }, # row
178
+ "dot3StatsIndex" : {
179
+ "nodetype" : "column",
180
+ "moduleName" : "EtherLike-MIB",
181
+ "oid" : "1.3.6.1.2.1.10.7.2.1.1",
182
+ "status" : "current",
183
+ "syntax" : {
184
+ "type" : { "module" :"IF-MIB", "name" : "InterfaceIndex"},
185
+ },
186
+ "access" : "readonly",
187
+ "description" :
188
+ """An index value that uniquely identifies an
189
+ interface to an ethernet-like medium. The
190
+ interface identified by a particular value of
191
+ this index is the same interface as identified
192
+ by the same value of ifIndex.""",
193
+ "reference" :
194
+ """RFC 2863, ifIndex""",
195
+ }, # column
196
+ "dot3StatsAlignmentErrors" : {
197
+ "nodetype" : "column",
198
+ "moduleName" : "EtherLike-MIB",
199
+ "oid" : "1.3.6.1.2.1.10.7.2.1.2",
200
+ "status" : "current",
201
+ "syntax" : {
202
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
203
+ },
204
+ "access" : "readonly",
205
+ "description" :
206
+ """A count of frames received on a particular
207
+ interface that are not an integral number of
208
+ octets in length and do not pass the FCS check.
209
+
210
+ The count represented by an instance of this
211
+ object is incremented when the alignmentError
212
+ status is returned by the MAC service to the
213
+ LLC (or other MAC user). Received frames for
214
+ which multiple error conditions pertain are,
215
+ according to the conventions of IEEE 802.3
216
+ Layer Management, counted exclusively according
217
+
218
+
219
+
220
+ to the error status presented to the LLC.
221
+
222
+ This counter does not increment for group
223
+ encoding schemes greater than 4 bits per group.
224
+
225
+ For interfaces operating at 10 Gb/s, this
226
+ counter can roll over in less than 5 minutes if
227
+ it is incrementing at its maximum rate. Since
228
+ that amount of time could be less than a
229
+ management station's poll cycle time, in order
230
+ to avoid a loss of information, a management
231
+ station is advised to poll the
232
+ dot3HCStatsAlignmentErrors object for 10 Gb/s
233
+ or faster interfaces.
234
+
235
+ Discontinuities in the value of this counter can
236
+ occur at re-initialization of the management
237
+ system, and at other times as indicated by the
238
+ value of ifCounterDiscontinuityTime.""",
239
+ "reference" :
240
+ """[IEEE 802.3 Std.], 30.3.1.1.7,
241
+ aAlignmentErrors""",
242
+ }, # column
243
+ "dot3StatsFCSErrors" : {
244
+ "nodetype" : "column",
245
+ "moduleName" : "EtherLike-MIB",
246
+ "oid" : "1.3.6.1.2.1.10.7.2.1.3",
247
+ "status" : "current",
248
+ "syntax" : {
249
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
250
+ },
251
+ "access" : "readonly",
252
+ "description" :
253
+ """A count of frames received on a particular
254
+ interface that are an integral number of octets
255
+ in length but do not pass the FCS check. This
256
+ count does not include frames received with
257
+ frame-too-long or frame-too-short error.
258
+
259
+ The count represented by an instance of this
260
+ object is incremented when the frameCheckError
261
+ status is returned by the MAC service to the
262
+ LLC (or other MAC user). Received frames for
263
+ which multiple error conditions pertain are,
264
+ according to the conventions of IEEE 802.3
265
+ Layer Management, counted exclusively according
266
+ to the error status presented to the LLC.
267
+
268
+ Note: Coding errors detected by the physical
269
+ layer for speeds above 10 Mb/s will cause the
270
+ frame to fail the FCS check.
271
+
272
+ For interfaces operating at 10 Gb/s, this
273
+ counter can roll over in less than 5 minutes if
274
+
275
+
276
+
277
+ it is incrementing at its maximum rate. Since
278
+ that amount of time could be less than a
279
+ management station's poll cycle time, in order
280
+ to avoid a loss of information, a management
281
+ station is advised to poll the
282
+ dot3HCStatsFCSErrors object for 10 Gb/s or
283
+ faster interfaces.
284
+
285
+ Discontinuities in the value of this counter can
286
+ occur at re-initialization of the management
287
+ system, and at other times as indicated by the
288
+ value of ifCounterDiscontinuityTime.""",
289
+ "reference" :
290
+ """[IEEE 802.3 Std.], 30.3.1.1.6,
291
+ aFrameCheckSequenceErrors.""",
292
+ }, # column
293
+ "dot3StatsSingleCollisionFrames" : {
294
+ "nodetype" : "column",
295
+ "moduleName" : "EtherLike-MIB",
296
+ "oid" : "1.3.6.1.2.1.10.7.2.1.4",
297
+ "status" : "current",
298
+ "syntax" : {
299
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
300
+ },
301
+ "access" : "readonly",
302
+ "description" :
303
+ """A count of frames that are involved in a single
304
+ collision, and are subsequently transmitted
305
+ successfully.
306
+
307
+ A frame that is counted by an instance of this
308
+ object is also counted by the corresponding
309
+ instance of either the ifOutUcastPkts,
310
+ ifOutMulticastPkts, or ifOutBroadcastPkts,
311
+ and is not counted by the corresponding
312
+ instance of the dot3StatsMultipleCollisionFrames
313
+ object.
314
+
315
+ This counter does not increment when the
316
+ interface is operating in full-duplex mode.
317
+
318
+ Discontinuities in the value of this counter can
319
+ occur at re-initialization of the management
320
+ system, and at other times as indicated by the
321
+ value of ifCounterDiscontinuityTime.""",
322
+ "reference" :
323
+ """[IEEE 802.3 Std.], 30.3.1.1.3,
324
+ aSingleCollisionFrames.""",
325
+ }, # column
326
+ "dot3StatsMultipleCollisionFrames" : {
327
+ "nodetype" : "column",
328
+ "moduleName" : "EtherLike-MIB",
329
+ "oid" : "1.3.6.1.2.1.10.7.2.1.5",
330
+ "status" : "current",
331
+ "syntax" : {
332
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
333
+ },
334
+ "access" : "readonly",
335
+ "description" :
336
+ """A count of frames that are involved in more
337
+
338
+
339
+
340
+ than one collision and are subsequently
341
+ transmitted successfully.
342
+
343
+ A frame that is counted by an instance of this
344
+ object is also counted by the corresponding
345
+ instance of either the ifOutUcastPkts,
346
+ ifOutMulticastPkts, or ifOutBroadcastPkts,
347
+ and is not counted by the corresponding
348
+ instance of the dot3StatsSingleCollisionFrames
349
+ object.
350
+
351
+ This counter does not increment when the
352
+ interface is operating in full-duplex mode.
353
+
354
+ Discontinuities in the value of this counter can
355
+ occur at re-initialization of the management
356
+ system, and at other times as indicated by the
357
+ value of ifCounterDiscontinuityTime.""",
358
+ "reference" :
359
+ """[IEEE 802.3 Std.], 30.3.1.1.4,
360
+ aMultipleCollisionFrames.""",
361
+ }, # column
362
+ "dot3StatsSQETestErrors" : {
363
+ "nodetype" : "column",
364
+ "moduleName" : "EtherLike-MIB",
365
+ "oid" : "1.3.6.1.2.1.10.7.2.1.6",
366
+ "status" : "current",
367
+ "syntax" : {
368
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
369
+ },
370
+ "access" : "readonly",
371
+ "description" :
372
+ """A count of times that the SQE TEST ERROR
373
+ is received on a particular interface. The
374
+ SQE TEST ERROR is set in accordance with the
375
+ rules for verification of the SQE detection
376
+ mechanism in the PLS Carrier Sense Function as
377
+ described in IEEE Std. 802.3, 2000 Edition,
378
+ section 7.2.4.6.
379
+
380
+ This counter does not increment on interfaces
381
+ operating at speeds greater than 10 Mb/s, or on
382
+ interfaces operating in full-duplex mode.
383
+
384
+ Discontinuities in the value of this counter can
385
+ occur at re-initialization of the management
386
+ system, and at other times as indicated by the
387
+ value of ifCounterDiscontinuityTime.""",
388
+ "reference" :
389
+ """[IEEE 802.3 Std.], 7.2.4.6, also 30.3.2.1.4,
390
+ aSQETestErrors.""",
391
+ }, # column
392
+ "dot3StatsDeferredTransmissions" : {
393
+ "nodetype" : "column",
394
+ "moduleName" : "EtherLike-MIB",
395
+ "oid" : "1.3.6.1.2.1.10.7.2.1.7",
396
+ "status" : "current",
397
+ "syntax" : {
398
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
399
+ },
400
+ "access" : "readonly",
401
+ "description" :
402
+ """A count of frames for which the first
403
+ transmission attempt on a particular interface
404
+ is delayed because the medium is busy.
405
+
406
+ The count represented by an instance of this
407
+ object does not include frames involved in
408
+ collisions.
409
+
410
+ This counter does not increment when the
411
+ interface is operating in full-duplex mode.
412
+
413
+ Discontinuities in the value of this counter can
414
+ occur at re-initialization of the management
415
+ system, and at other times as indicated by the
416
+ value of ifCounterDiscontinuityTime.""",
417
+ "reference" :
418
+ """[IEEE 802.3 Std.], 30.3.1.1.9,
419
+ aFramesWithDeferredXmissions.""",
420
+ }, # column
421
+ "dot3StatsLateCollisions" : {
422
+ "nodetype" : "column",
423
+ "moduleName" : "EtherLike-MIB",
424
+ "oid" : "1.3.6.1.2.1.10.7.2.1.8",
425
+ "status" : "current",
426
+ "syntax" : {
427
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
428
+ },
429
+ "access" : "readonly",
430
+ "description" :
431
+ """The number of times that a collision is
432
+ detected on a particular interface later than
433
+ one slotTime into the transmission of a packet.
434
+
435
+ A (late) collision included in a count
436
+ represented by an instance of this object is
437
+ also considered as a (generic) collision for
438
+ purposes of other collision-related
439
+ statistics.
440
+
441
+ This counter does not increment when the
442
+ interface is operating in full-duplex mode.
443
+
444
+ Discontinuities in the value of this counter can
445
+ occur at re-initialization of the management
446
+ system, and at other times as indicated by the
447
+ value of ifCounterDiscontinuityTime.""",
448
+ "reference" :
449
+ """[IEEE 802.3 Std.], 30.3.1.1.10,
450
+ aLateCollisions.""",
451
+ }, # column
452
+ "dot3StatsExcessiveCollisions" : {
453
+ "nodetype" : "column",
454
+ "moduleName" : "EtherLike-MIB",
455
+ "oid" : "1.3.6.1.2.1.10.7.2.1.9",
456
+ "status" : "current",
457
+ "syntax" : {
458
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
459
+ },
460
+ "access" : "readonly",
461
+ "description" :
462
+ """A count of frames for which transmission on a
463
+ particular interface fails due to excessive
464
+ collisions.
465
+
466
+ This counter does not increment when the
467
+ interface is operating in full-duplex mode.
468
+
469
+ Discontinuities in the value of this counter can
470
+ occur at re-initialization of the management
471
+ system, and at other times as indicated by the
472
+ value of ifCounterDiscontinuityTime.""",
473
+ "reference" :
474
+ """[IEEE 802.3 Std.], 30.3.1.1.11,
475
+ aFramesAbortedDueToXSColls.""",
476
+ }, # column
477
+ "dot3StatsInternalMacTransmitErrors" : {
478
+ "nodetype" : "column",
479
+ "moduleName" : "EtherLike-MIB",
480
+ "oid" : "1.3.6.1.2.1.10.7.2.1.10",
481
+ "status" : "current",
482
+ "syntax" : {
483
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
484
+ },
485
+ "access" : "readonly",
486
+ "description" :
487
+ """A count of frames for which transmission on a
488
+ particular interface fails due to an internal
489
+ MAC sublayer transmit error. A frame is only
490
+ counted by an instance of this object if it is
491
+ not counted by the corresponding instance of
492
+ either the dot3StatsLateCollisions object, the
493
+ dot3StatsExcessiveCollisions object, or the
494
+ dot3StatsCarrierSenseErrors object.
495
+
496
+ The precise meaning of the count represented by
497
+ an instance of this object is implementation-
498
+ specific. In particular, an instance of this
499
+ object may represent a count of transmission
500
+ errors on a particular interface that are not
501
+ otherwise counted.
502
+
503
+ For interfaces operating at 10 Gb/s, this
504
+ counter can roll over in less than 5 minutes if
505
+ it is incrementing at its maximum rate. Since
506
+ that amount of time could be less than a
507
+ management station's poll cycle time, in order
508
+ to avoid a loss of information, a management
509
+ station is advised to poll the
510
+ dot3HCStatsInternalMacTransmitErrors object for
511
+ 10 Gb/s or faster interfaces.
512
+
513
+ Discontinuities in the value of this counter can
514
+
515
+
516
+
517
+ occur at re-initialization of the management
518
+ system, and at other times as indicated by the
519
+ value of ifCounterDiscontinuityTime.""",
520
+ "reference" :
521
+ """[IEEE 802.3 Std.], 30.3.1.1.12,
522
+ aFramesLostDueToIntMACXmitError.""",
523
+ }, # column
524
+ "dot3StatsCarrierSenseErrors" : {
525
+ "nodetype" : "column",
526
+ "moduleName" : "EtherLike-MIB",
527
+ "oid" : "1.3.6.1.2.1.10.7.2.1.11",
528
+ "status" : "current",
529
+ "syntax" : {
530
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
531
+ },
532
+ "access" : "readonly",
533
+ "description" :
534
+ """The number of times that the carrier sense
535
+ condition was lost or never asserted when
536
+ attempting to transmit a frame on a particular
537
+ interface.
538
+
539
+ The count represented by an instance of this
540
+ object is incremented at most once per
541
+ transmission attempt, even if the carrier sense
542
+ condition fluctuates during a transmission
543
+ attempt.
544
+
545
+ This counter does not increment when the
546
+ interface is operating in full-duplex mode.
547
+
548
+ Discontinuities in the value of this counter can
549
+ occur at re-initialization of the management
550
+ system, and at other times as indicated by the
551
+ value of ifCounterDiscontinuityTime.""",
552
+ "reference" :
553
+ """[IEEE 802.3 Std.], 30.3.1.1.13,
554
+ aCarrierSenseErrors.""",
555
+ }, # column
556
+ "dot3StatsFrameTooLongs" : {
557
+ "nodetype" : "column",
558
+ "moduleName" : "EtherLike-MIB",
559
+ "oid" : "1.3.6.1.2.1.10.7.2.1.13",
560
+ "status" : "current",
561
+ "syntax" : {
562
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
563
+ },
564
+ "access" : "readonly",
565
+ "description" :
566
+ """A count of frames received on a particular
567
+ interface that exceed the maximum permitted
568
+ frame size.
569
+
570
+ The count represented by an instance of this
571
+ object is incremented when the frameTooLong
572
+ status is returned by the MAC service to the
573
+ LLC (or other MAC user). Received frames for
574
+ which multiple error conditions pertain are,
575
+
576
+
577
+
578
+ according to the conventions of IEEE 802.3
579
+ Layer Management, counted exclusively according
580
+ to the error status presented to the LLC.
581
+
582
+ For interfaces operating at 10 Gb/s, this
583
+ counter can roll over in less than 80 minutes if
584
+ it is incrementing at its maximum rate. Since
585
+ that amount of time could be less than a
586
+ management station's poll cycle time, in order
587
+ to avoid a loss of information, a management
588
+ station is advised to poll the
589
+ dot3HCStatsFrameTooLongs object for 10 Gb/s
590
+ or faster interfaces.
591
+
592
+ Discontinuities in the value of this counter can
593
+ occur at re-initialization of the management
594
+ system, and at other times as indicated by the
595
+ value of ifCounterDiscontinuityTime.""",
596
+ "reference" :
597
+ """[IEEE 802.3 Std.], 30.3.1.1.25,
598
+ aFrameTooLongErrors.""",
599
+ }, # column
600
+ "dot3StatsInternalMacReceiveErrors" : {
601
+ "nodetype" : "column",
602
+ "moduleName" : "EtherLike-MIB",
603
+ "oid" : "1.3.6.1.2.1.10.7.2.1.16",
604
+ "status" : "current",
605
+ "syntax" : {
606
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
607
+ },
608
+ "access" : "readonly",
609
+ "description" :
610
+ """A count of frames for which reception on a
611
+ particular interface fails due to an internal
612
+ MAC sublayer receive error. A frame is only
613
+ counted by an instance of this object if it is
614
+ not counted by the corresponding instance of
615
+ either the dot3StatsFrameTooLongs object, the
616
+ dot3StatsAlignmentErrors object, or the
617
+ dot3StatsFCSErrors object.
618
+
619
+ The precise meaning of the count represented by
620
+ an instance of this object is implementation-
621
+ specific. In particular, an instance of this
622
+ object may represent a count of receive errors
623
+ on a particular interface that are not
624
+ otherwise counted.
625
+
626
+ For interfaces operating at 10 Gb/s, this
627
+ counter can roll over in less than 5 minutes if
628
+
629
+
630
+
631
+ it is incrementing at its maximum rate. Since
632
+ that amount of time could be less than a
633
+ management station's poll cycle time, in order
634
+ to avoid a loss of information, a management
635
+ station is advised to poll the
636
+ dot3HCStatsInternalMacReceiveErrors object for
637
+ 10 Gb/s or faster interfaces.
638
+
639
+ Discontinuities in the value of this counter can
640
+ occur at re-initialization of the management
641
+ system, and at other times as indicated by the
642
+ value of ifCounterDiscontinuityTime.""",
643
+ "reference" :
644
+ """[IEEE 802.3 Std.], 30.3.1.1.15,
645
+ aFramesLostDueToIntMACRcvError.""",
646
+ }, # column
647
+ "dot3StatsEtherChipSet" : {
648
+ "nodetype" : "column",
649
+ "moduleName" : "EtherLike-MIB",
650
+ "oid" : "1.3.6.1.2.1.10.7.2.1.17",
651
+ "status" : "deprecated",
652
+ "syntax" : {
653
+ "type" : { "module" :"", "name" : "ObjectIdentifier"},
654
+ },
655
+ "access" : "readonly",
656
+ "description" :
657
+ """******** THIS OBJECT IS DEPRECATED ********
658
+
659
+ This object contains an OBJECT IDENTIFIER
660
+ which identifies the chipset used to
661
+ realize the interface. Ethernet-like
662
+ interfaces are typically built out of
663
+ several different chips. The MIB implementor
664
+ is presented with a decision of which chip
665
+ to identify via this object. The implementor
666
+ should identify the chip which is usually
667
+ called the Medium Access Control chip.
668
+ If no such chip is easily identifiable,
669
+ the implementor should identify the chip
670
+ which actually gathers the transmit
671
+ and receive statistics and error
672
+ indications. This would allow a
673
+ manager station to correlate the
674
+ statistics and the chip generating
675
+ them, giving it the ability to take
676
+ into account any known anomalies
677
+ in the chip.
678
+
679
+ This object has been deprecated. Implementation
680
+ feedback indicates that it is of limited use for
681
+ debugging network problems in the field, and
682
+ the administrative overhead involved in
683
+ maintaining a registry of chipset OIDs is not
684
+ justified.""",
685
+ }, # column
686
+ "dot3StatsSymbolErrors" : {
687
+ "nodetype" : "column",
688
+ "moduleName" : "EtherLike-MIB",
689
+ "oid" : "1.3.6.1.2.1.10.7.2.1.18",
690
+ "status" : "current",
691
+ "syntax" : {
692
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
693
+ },
694
+ "access" : "readonly",
695
+ "description" :
696
+ """For an interface operating at 100 Mb/s, the
697
+ number of times there was an invalid data symbol
698
+ when a valid carrier was present.
699
+
700
+ For an interface operating in half-duplex mode
701
+ at 1000 Mb/s, the number of times the receiving
702
+ media is non-idle (a carrier event) for a period
703
+ of time equal to or greater than slotTime, and
704
+ during which there was at least one occurrence
705
+ of an event that causes the PHY to indicate
706
+ 'Data reception error' or 'carrier extend error'
707
+ on the GMII.
708
+
709
+ For an interface operating in full-duplex mode
710
+ at 1000 Mb/s, the number of times the receiving
711
+ media is non-idle (a carrier event) for a period
712
+ of time equal to or greater than minFrameSize,
713
+ and during which there was at least one
714
+ occurrence of an event that causes the PHY to
715
+ indicate 'Data reception error' on the GMII.
716
+
717
+ For an interface operating at 10 Gb/s, the
718
+ number of times the receiving media is non-idle
719
+ (a carrier event) for a period of time equal to
720
+ or greater than minFrameSize, and during which
721
+ there was at least one occurrence of an event
722
+ that causes the PHY to indicate 'Receive Error'
723
+ on the XGMII.
724
+
725
+ The count represented by an instance of this
726
+ object is incremented at most once per carrier
727
+ event, even if multiple symbol errors occur
728
+ during the carrier event. This count does
729
+ not increment if a collision is present.
730
+
731
+ This counter does not increment when the
732
+ interface is operating at 10 Mb/s.
733
+
734
+ For interfaces operating at 10 Gb/s, this
735
+ counter can roll over in less than 5 minutes if
736
+ it is incrementing at its maximum rate. Since
737
+ that amount of time could be less than a
738
+
739
+
740
+
741
+ management station's poll cycle time, in order
742
+ to avoid a loss of information, a management
743
+ station is advised to poll the
744
+ dot3HCStatsSymbolErrors object for 10 Gb/s
745
+ or faster interfaces.
746
+
747
+ Discontinuities in the value of this counter can
748
+ occur at re-initialization of the management
749
+ system, and at other times as indicated by the
750
+ value of ifCounterDiscontinuityTime.""",
751
+ "reference" :
752
+ """[IEEE 802.3 Std.], 30.3.2.1.5,
753
+ aSymbolErrorDuringCarrier.""",
754
+ }, # column
755
+ "dot3StatsDuplexStatus" : {
756
+ "nodetype" : "column",
757
+ "moduleName" : "EtherLike-MIB",
758
+ "oid" : "1.3.6.1.2.1.10.7.2.1.19",
759
+ "status" : "current",
760
+ "syntax" : {
761
+ "type" : {
762
+ "basetype" : "Enumeration",
763
+ "unknown" : {
764
+ "nodetype" : "namednumber",
765
+ "number" : "1"
766
+ },
767
+ "halfDuplex" : {
768
+ "nodetype" : "namednumber",
769
+ "number" : "2"
770
+ },
771
+ "fullDuplex" : {
772
+ "nodetype" : "namednumber",
773
+ "number" : "3"
774
+ },
775
+ },
776
+ },
777
+ "access" : "readonly",
778
+ "description" :
779
+ """The current mode of operation of the MAC
780
+ entity. 'unknown' indicates that the current
781
+ duplex mode could not be determined.
782
+
783
+ Management control of the duplex mode is
784
+ accomplished through the MAU MIB. When
785
+ an interface does not support autonegotiation,
786
+ or when autonegotiation is not enabled, the
787
+ duplex mode is controlled using
788
+ ifMauDefaultType. When autonegotiation is
789
+ supported and enabled, duplex mode is controlled
790
+ using ifMauAutoNegAdvertisedBits. In either
791
+ case, the currently operating duplex mode is
792
+ reflected both in this object and in ifMauType.
793
+
794
+ Note that this object provides redundant
795
+ information with ifMauType. Normally, redundant
796
+ objects are discouraged. However, in this
797
+ instance, it allows a management application to
798
+ determine the duplex status of an interface
799
+ without having to know every possible value of
800
+ ifMauType. This was felt to be sufficiently
801
+ valuable to justify the redundancy.""",
802
+ "reference" :
803
+ """[IEEE 802.3 Std.], 30.3.1.1.32,
804
+ aDuplexStatus.""",
805
+ }, # column
806
+ "dot3StatsRateControlAbility" : {
807
+ "nodetype" : "column",
808
+ "moduleName" : "EtherLike-MIB",
809
+ "oid" : "1.3.6.1.2.1.10.7.2.1.20",
810
+ "status" : "current",
811
+ "syntax" : {
812
+ "type" : { "module" :"SNMPv2-TC", "name" : "TruthValue"},
813
+ },
814
+ "access" : "readonly",
815
+ "description" :
816
+ """'true' for interfaces operating at speeds above
817
+ 1000 Mb/s that support Rate Control through
818
+ lowering the average data rate of the MAC
819
+ sublayer, with frame granularity, and 'false'
820
+ otherwise.""",
821
+ "reference" :
822
+ """[IEEE 802.3 Std.], 30.3.1.1.33,
823
+ aRateControlAbility.""",
824
+ }, # column
825
+ "dot3StatsRateControlStatus" : {
826
+ "nodetype" : "column",
827
+ "moduleName" : "EtherLike-MIB",
828
+ "oid" : "1.3.6.1.2.1.10.7.2.1.21",
829
+ "status" : "current",
830
+ "syntax" : {
831
+ "type" : {
832
+ "basetype" : "Enumeration",
833
+ "rateControlOff" : {
834
+ "nodetype" : "namednumber",
835
+ "number" : "1"
836
+ },
837
+ "rateControlOn" : {
838
+ "nodetype" : "namednumber",
839
+ "number" : "2"
840
+ },
841
+ "unknown" : {
842
+ "nodetype" : "namednumber",
843
+ "number" : "3"
844
+ },
845
+ },
846
+ },
847
+ "access" : "readonly",
848
+ "description" :
849
+ """The current Rate Control mode of operation of
850
+ the MAC sublayer of this interface.""",
851
+ "reference" :
852
+ """[IEEE 802.3 Std.], 30.3.1.1.34,
853
+ aRateControlStatus.""",
854
+ }, # column
855
+ "dot3CollTable" : {
856
+ "nodetype" : "table",
857
+ "moduleName" : "EtherLike-MIB",
858
+ "oid" : "1.3.6.1.2.1.10.7.5",
859
+ "status" : "current",
860
+ "description" :
861
+ """A collection of collision histograms for a
862
+ particular set of interfaces.""",
863
+ "reference" :
864
+ """[IEEE 802.3 Std.], 30.3.1.1.30,
865
+ aCollisionFrames.""",
866
+ }, # table
867
+ "dot3CollEntry" : {
868
+ "nodetype" : "row",
869
+ "moduleName" : "EtherLike-MIB",
870
+ "oid" : "1.3.6.1.2.1.10.7.5.1",
871
+ "status" : "current",
872
+ "linkage" : [
873
+ "ifIndex",
874
+ "dot3CollCount",
875
+ ],
876
+ "description" :
877
+ """A cell in the histogram of per-frame
878
+ collisions for a particular interface. An
879
+
880
+
881
+
882
+ instance of this object represents the
883
+ frequency of individual MAC frames for which
884
+ the transmission (successful or otherwise) on a
885
+ particular interface is accompanied by a
886
+ particular number of media collisions.""",
887
+ }, # row
888
+ "dot3CollCount" : {
889
+ "nodetype" : "column",
890
+ "moduleName" : "EtherLike-MIB",
891
+ "oid" : "1.3.6.1.2.1.10.7.5.1.2",
892
+ "status" : "current",
893
+ "syntax" : {
894
+ "type" : {
895
+ "basetype" : "Integer32",
896
+ "ranges" : [
897
+ {
898
+ "min" : "1",
899
+ "max" : "16"
900
+ },
901
+ ],
902
+ "range" : {
903
+ "min" : "1",
904
+ "max" : "16"
905
+ },
906
+ },
907
+ },
908
+ "access" : "noaccess",
909
+ "description" :
910
+ """The number of per-frame media collisions for
911
+ which a particular collision histogram cell
912
+ represents the frequency on a particular
913
+ interface.""",
914
+ }, # column
915
+ "dot3CollFrequencies" : {
916
+ "nodetype" : "column",
917
+ "moduleName" : "EtherLike-MIB",
918
+ "oid" : "1.3.6.1.2.1.10.7.5.1.3",
919
+ "status" : "current",
920
+ "syntax" : {
921
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
922
+ },
923
+ "access" : "readonly",
924
+ "description" :
925
+ """A count of individual MAC frames for which the
926
+ transmission (successful or otherwise) on a
927
+ particular interface occurs after the
928
+ frame has experienced exactly the number
929
+ of collisions in the associated
930
+ dot3CollCount object.
931
+
932
+ For example, a frame which is transmitted
933
+ on interface 77 after experiencing
934
+ exactly 4 collisions would be indicated
935
+ by incrementing only dot3CollFrequencies.77.4.
936
+ No other instance of dot3CollFrequencies would
937
+ be incremented in this example.
938
+
939
+ This counter does not increment when the
940
+ interface is operating in full-duplex mode.
941
+
942
+ Discontinuities in the value of this counter can
943
+
944
+
945
+
946
+ occur at re-initialization of the management
947
+ system, and at other times as indicated by the
948
+ value of ifCounterDiscontinuityTime.""",
949
+ }, # column
950
+ "dot3Tests" : {
951
+ "nodetype" : "node",
952
+ "moduleName" : "EtherLike-MIB",
953
+ "oid" : "1.3.6.1.2.1.10.7.6",
954
+ }, # node
955
+ "dot3TestTdr" : {
956
+ "nodetype" : "node",
957
+ "moduleName" : "EtherLike-MIB",
958
+ "oid" : "1.3.6.1.2.1.10.7.6.1",
959
+ "status" : "deprecated",
960
+ "description" :
961
+ """******** THIS IDENTITY IS DEPRECATED *******
962
+
963
+ The Time-Domain Reflectometry (TDR) test is
964
+ specific to ethernet-like interfaces of type
965
+ 10Base5 and 10Base2. The TDR value may be
966
+ useful in determining the approximate distance
967
+ to a cable fault. It is advisable to repeat
968
+ this test to check for a consistent resulting
969
+ TDR value, to verify that there is a fault.
970
+
971
+ A TDR test returns as its result the time
972
+ interval, measured in 10 MHz ticks or 100 nsec
973
+ units, between the start of TDR test
974
+ transmission and the subsequent detection of a
975
+ collision or deassertion of carrier. On
976
+ successful completion of a TDR test, the result
977
+ is stored as the value of an appropriate
978
+ instance of an appropriate vendor specific MIB
979
+ object, and the OBJECT IDENTIFIER of that
980
+ instance is stored in the appropriate instance
981
+ of the appropriate test result code object
982
+ (thereby indicating where the result has been
983
+ stored).
984
+
985
+ This object identity has been deprecated, since
986
+ the ifTestTable in the IF-MIB was deprecated,
987
+ and there is no longer a standard mechanism for
988
+ initiating an interface test. This left no
989
+ standard way of using this object identity.""",
990
+ }, # node
991
+ "dot3TestLoopBack" : {
992
+ "nodetype" : "node",
993
+ "moduleName" : "EtherLike-MIB",
994
+ "oid" : "1.3.6.1.2.1.10.7.6.2",
995
+ "status" : "deprecated",
996
+ "description" :
997
+ """******** THIS IDENTITY IS DEPRECATED *******
998
+
999
+ This test configures the MAC chip and executes
1000
+ an internal loopback test of memory, data paths,
1001
+ and the MAC chip logic. This loopback test can
1002
+ only be executed if the interface is offline.
1003
+ Once the test has completed, the MAC chip should
1004
+
1005
+
1006
+
1007
+ be reinitialized for network operation, but it
1008
+ should remain offline.
1009
+
1010
+ If an error occurs during a test, the
1011
+ appropriate test result object will be set
1012
+ to indicate a failure. The two OBJECT
1013
+ IDENTIFIER values dot3ErrorInitError and
1014
+ dot3ErrorLoopbackError may be used to provided
1015
+ more information as values for an appropriate
1016
+ test result code object.
1017
+
1018
+ This object identity has been deprecated, since
1019
+ the ifTestTable in the IF-MIB was deprecated,
1020
+ and there is no longer a standard mechanism for
1021
+ initiating an interface test. This left no
1022
+ standard way of using this object identity.""",
1023
+ }, # node
1024
+ "dot3Errors" : {
1025
+ "nodetype" : "node",
1026
+ "moduleName" : "EtherLike-MIB",
1027
+ "oid" : "1.3.6.1.2.1.10.7.7",
1028
+ }, # node
1029
+ "dot3ErrorInitError" : {
1030
+ "nodetype" : "node",
1031
+ "moduleName" : "EtherLike-MIB",
1032
+ "oid" : "1.3.6.1.2.1.10.7.7.1",
1033
+ "status" : "deprecated",
1034
+ "description" :
1035
+ """******** THIS IDENTITY IS DEPRECATED *******
1036
+
1037
+ Couldn't initialize MAC chip for test.
1038
+
1039
+ This object identity has been deprecated, since
1040
+ the ifTestTable in the IF-MIB was deprecated,
1041
+ and there is no longer a standard mechanism for
1042
+ initiating an interface test. This left no
1043
+ standard way of using this object identity.""",
1044
+ }, # node
1045
+ "dot3ErrorLoopbackError" : {
1046
+ "nodetype" : "node",
1047
+ "moduleName" : "EtherLike-MIB",
1048
+ "oid" : "1.3.6.1.2.1.10.7.7.2",
1049
+ "status" : "deprecated",
1050
+ "description" :
1051
+ """******** THIS IDENTITY IS DEPRECATED *******
1052
+
1053
+ Expected data not received (or not received
1054
+ correctly) in loopback test.
1055
+
1056
+ This object identity has been deprecated, since
1057
+ the ifTestTable in the IF-MIB was deprecated,
1058
+ and there is no longer a standard mechanism for
1059
+ initiating an interface test. This left no
1060
+ standard way of using this object identity.""",
1061
+ }, # node
1062
+ "dot3ControlTable" : {
1063
+ "nodetype" : "table",
1064
+ "moduleName" : "EtherLike-MIB",
1065
+ "oid" : "1.3.6.1.2.1.10.7.9",
1066
+ "status" : "current",
1067
+ "description" :
1068
+ """A table of descriptive and status information
1069
+ about the MAC Control sublayer on the
1070
+ ethernet-like interfaces attached to a
1071
+ particular system. There will be one row in
1072
+ this table for each ethernet-like interface in
1073
+ the system which implements the MAC Control
1074
+ sublayer. If some, but not all, of the
1075
+ ethernet-like interfaces in the system implement
1076
+ the MAC Control sublayer, there will be fewer
1077
+ rows in this table than in the dot3StatsTable.""",
1078
+ }, # table
1079
+ "dot3ControlEntry" : {
1080
+ "nodetype" : "row",
1081
+ "moduleName" : "EtherLike-MIB",
1082
+ "oid" : "1.3.6.1.2.1.10.7.9.1",
1083
+ "status" : "current",
1084
+ "linkage" : [
1085
+ "dot3StatsIndex",
1086
+ ],
1087
+ "description" :
1088
+ """An entry in the table, containing information
1089
+ about the MAC Control sublayer on a single
1090
+ ethernet-like interface.""",
1091
+ }, # row
1092
+ "dot3ControlFunctionsSupported" : {
1093
+ "nodetype" : "column",
1094
+ "moduleName" : "EtherLike-MIB",
1095
+ "oid" : "1.3.6.1.2.1.10.7.9.1.1",
1096
+ "status" : "current",
1097
+ "syntax" : {
1098
+ "type" : {
1099
+ "basetype" : "Bits",
1100
+ "pause" : {
1101
+ "nodetype" : "namednumber",
1102
+ "number" : "0"
1103
+ },
1104
+ },
1105
+ },
1106
+ "access" : "readonly",
1107
+ "description" :
1108
+ """A list of the possible MAC Control functions
1109
+ implemented for this interface.""",
1110
+ "reference" :
1111
+ """[IEEE 802.3 Std.], 30.3.3.2,
1112
+ aMACControlFunctionsSupported.""",
1113
+ }, # column
1114
+ "dot3ControlInUnknownOpcodes" : {
1115
+ "nodetype" : "column",
1116
+ "moduleName" : "EtherLike-MIB",
1117
+ "oid" : "1.3.6.1.2.1.10.7.9.1.2",
1118
+ "status" : "current",
1119
+ "syntax" : {
1120
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
1121
+ },
1122
+ "access" : "readonly",
1123
+ "description" :
1124
+ """A count of MAC Control frames received on this
1125
+ interface that contain an opcode that is not
1126
+ supported by this device.
1127
+
1128
+ For interfaces operating at 10 Gb/s, this
1129
+ counter can roll over in less than 5 minutes if
1130
+ it is incrementing at its maximum rate. Since
1131
+ that amount of time could be less than a
1132
+ management station's poll cycle time, in order
1133
+ to avoid a loss of information, a management
1134
+ station is advised to poll the
1135
+ dot3HCControlInUnknownOpcodes object for 10 Gb/s
1136
+ or faster interfaces.
1137
+
1138
+ Discontinuities in the value of this counter can
1139
+ occur at re-initialization of the management
1140
+ system, and at other times as indicated by the
1141
+ value of ifCounterDiscontinuityTime.""",
1142
+ "reference" :
1143
+ """[IEEE 802.3 Std.], 30.3.3.5,
1144
+ aUnsupportedOpcodesReceived""",
1145
+ }, # column
1146
+ "dot3HCControlInUnknownOpcodes" : {
1147
+ "nodetype" : "column",
1148
+ "moduleName" : "EtherLike-MIB",
1149
+ "oid" : "1.3.6.1.2.1.10.7.9.1.3",
1150
+ "status" : "current",
1151
+ "syntax" : {
1152
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter64"},
1153
+ },
1154
+ "access" : "readonly",
1155
+ "description" :
1156
+ """A count of MAC Control frames received on this
1157
+ interface that contain an opcode that is not
1158
+ supported by this device.
1159
+
1160
+ This counter is a 64 bit version of
1161
+ dot3ControlInUnknownOpcodes. It should be used
1162
+ on interfaces operating at 10 Gb/s or faster.
1163
+
1164
+ Discontinuities in the value of this counter can
1165
+ occur at re-initialization of the management
1166
+ system, and at other times as indicated by the
1167
+ value of ifCounterDiscontinuityTime.""",
1168
+ "reference" :
1169
+ """[IEEE 802.3 Std.], 30.3.3.5,
1170
+ aUnsupportedOpcodesReceived""",
1171
+ }, # column
1172
+ "dot3PauseTable" : {
1173
+ "nodetype" : "table",
1174
+ "moduleName" : "EtherLike-MIB",
1175
+ "oid" : "1.3.6.1.2.1.10.7.10",
1176
+ "status" : "current",
1177
+ "description" :
1178
+ """A table of descriptive and status information
1179
+ about the MAC Control PAUSE function on the
1180
+ ethernet-like interfaces attached to a
1181
+ particular system. There will be one row in
1182
+ this table for each ethernet-like interface in
1183
+ the system which supports the MAC Control PAUSE
1184
+ function (i.e., the 'pause' bit in the
1185
+ corresponding instance of
1186
+ dot3ControlFunctionsSupported is set). If some,
1187
+ but not all, of the ethernet-like interfaces in
1188
+ the system implement the MAC Control PAUSE
1189
+ function (for example, if some interfaces only
1190
+ support half-duplex), there will be fewer rows
1191
+ in this table than in the dot3StatsTable.""",
1192
+ }, # table
1193
+ "dot3PauseEntry" : {
1194
+ "nodetype" : "row",
1195
+ "moduleName" : "EtherLike-MIB",
1196
+ "oid" : "1.3.6.1.2.1.10.7.10.1",
1197
+ "status" : "current",
1198
+ "linkage" : [
1199
+ "dot3StatsIndex",
1200
+ ],
1201
+ "description" :
1202
+ """An entry in the table, containing information
1203
+ about the MAC Control PAUSE function on a single
1204
+ ethernet-like interface.""",
1205
+ }, # row
1206
+ "dot3PauseAdminMode" : {
1207
+ "nodetype" : "column",
1208
+ "moduleName" : "EtherLike-MIB",
1209
+ "oid" : "1.3.6.1.2.1.10.7.10.1.1",
1210
+ "status" : "current",
1211
+ "syntax" : {
1212
+ "type" : {
1213
+ "basetype" : "Enumeration",
1214
+ "disabled" : {
1215
+ "nodetype" : "namednumber",
1216
+ "number" : "1"
1217
+ },
1218
+ "enabledXmit" : {
1219
+ "nodetype" : "namednumber",
1220
+ "number" : "2"
1221
+ },
1222
+ "enabledRcv" : {
1223
+ "nodetype" : "namednumber",
1224
+ "number" : "3"
1225
+ },
1226
+ "enabledXmitAndRcv" : {
1227
+ "nodetype" : "namednumber",
1228
+ "number" : "4"
1229
+ },
1230
+ },
1231
+ },
1232
+ "access" : "readwrite",
1233
+ "description" :
1234
+ """This object is used to configure the default
1235
+ administrative PAUSE mode for this interface.
1236
+
1237
+ This object represents the
1238
+ administratively-configured PAUSE mode for this
1239
+ interface. If auto-negotiation is not enabled
1240
+ or is not implemented for the active MAU
1241
+ attached to this interface, the value of this
1242
+ object determines the operational PAUSE mode
1243
+ of the interface whenever it is operating in
1244
+ full-duplex mode. In this case, a set to this
1245
+ object will force the interface into the
1246
+ specified mode.
1247
+
1248
+ If auto-negotiation is implemented and enabled
1249
+ for the MAU attached to this interface, the
1250
+ PAUSE mode for this interface is determined by
1251
+ auto-negotiation, and the value of this object
1252
+ denotes the mode to which the interface will
1253
+ automatically revert if/when auto-negotiation is
1254
+ later disabled. Note that when auto-negotiation
1255
+ is running, administrative control of the PAUSE
1256
+ mode may be accomplished using the
1257
+ ifMauAutoNegCapAdvertisedBits object in the
1258
+ MAU-MIB.
1259
+
1260
+ Note that the value of this object is ignored
1261
+ when the interface is not operating in
1262
+ full-duplex mode.
1263
+
1264
+ An attempt to set this object to
1265
+ 'enabledXmit(2)' or 'enabledRcv(3)' will fail
1266
+ on interfaces that do not support operation
1267
+ at greater than 100 Mb/s.""",
1268
+ }, # column
1269
+ "dot3PauseOperMode" : {
1270
+ "nodetype" : "column",
1271
+ "moduleName" : "EtherLike-MIB",
1272
+ "oid" : "1.3.6.1.2.1.10.7.10.1.2",
1273
+ "status" : "current",
1274
+ "syntax" : {
1275
+ "type" : {
1276
+ "basetype" : "Enumeration",
1277
+ "disabled" : {
1278
+ "nodetype" : "namednumber",
1279
+ "number" : "1"
1280
+ },
1281
+ "enabledXmit" : {
1282
+ "nodetype" : "namednumber",
1283
+ "number" : "2"
1284
+ },
1285
+ "enabledRcv" : {
1286
+ "nodetype" : "namednumber",
1287
+ "number" : "3"
1288
+ },
1289
+ "enabledXmitAndRcv" : {
1290
+ "nodetype" : "namednumber",
1291
+ "number" : "4"
1292
+ },
1293
+ },
1294
+ },
1295
+ "access" : "readonly",
1296
+ "description" :
1297
+ """This object reflects the PAUSE mode currently
1298
+
1299
+
1300
+
1301
+ in use on this interface, as determined by
1302
+ either (1) the result of the auto-negotiation
1303
+ function or (2) if auto-negotiation is not
1304
+ enabled or is not implemented for the active MAU
1305
+ attached to this interface, by the value of
1306
+ dot3PauseAdminMode. Interfaces operating at
1307
+ 100 Mb/s or less will never return
1308
+ 'enabledXmit(2)' or 'enabledRcv(3)'. Interfaces
1309
+ operating in half-duplex mode will always return
1310
+ 'disabled(1)'. Interfaces on which
1311
+ auto-negotiation is enabled but not yet
1312
+ completed should return the value
1313
+ 'disabled(1)'.""",
1314
+ }, # column
1315
+ "dot3InPauseFrames" : {
1316
+ "nodetype" : "column",
1317
+ "moduleName" : "EtherLike-MIB",
1318
+ "oid" : "1.3.6.1.2.1.10.7.10.1.3",
1319
+ "status" : "current",
1320
+ "syntax" : {
1321
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
1322
+ },
1323
+ "access" : "readonly",
1324
+ "description" :
1325
+ """A count of MAC Control frames received on this
1326
+ interface with an opcode indicating the PAUSE
1327
+ operation.
1328
+
1329
+ This counter does not increment when the
1330
+ interface is operating in half-duplex mode.
1331
+
1332
+ For interfaces operating at 10 Gb/s, this
1333
+ counter can roll over in less than 5 minutes if
1334
+ it is incrementing at its maximum rate. Since
1335
+ that amount of time could be less than a
1336
+ management station's poll cycle time, in order
1337
+ to avoid a loss of information, a management
1338
+ station is advised to poll the
1339
+ dot3HCInPauseFrames object for 10 Gb/s or
1340
+ faster interfaces.
1341
+
1342
+ Discontinuities in the value of this counter can
1343
+ occur at re-initialization of the management
1344
+ system, and at other times as indicated by the
1345
+ value of ifCounterDiscontinuityTime.""",
1346
+ "reference" :
1347
+ """[IEEE 802.3 Std.], 30.3.4.3,
1348
+ aPAUSEMACCtrlFramesReceived.""",
1349
+ }, # column
1350
+ "dot3OutPauseFrames" : {
1351
+ "nodetype" : "column",
1352
+ "moduleName" : "EtherLike-MIB",
1353
+ "oid" : "1.3.6.1.2.1.10.7.10.1.4",
1354
+ "status" : "current",
1355
+ "syntax" : {
1356
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
1357
+ },
1358
+ "access" : "readonly",
1359
+ "description" :
1360
+ """A count of MAC Control frames transmitted on
1361
+ this interface with an opcode indicating the
1362
+ PAUSE operation.
1363
+
1364
+ This counter does not increment when the
1365
+ interface is operating in half-duplex mode.
1366
+
1367
+ For interfaces operating at 10 Gb/s, this
1368
+ counter can roll over in less than 5 minutes if
1369
+ it is incrementing at its maximum rate. Since
1370
+ that amount of time could be less than a
1371
+ management station's poll cycle time, in order
1372
+ to avoid a loss of information, a management
1373
+ station is advised to poll the
1374
+ dot3HCOutPauseFrames object for 10 Gb/s or
1375
+ faster interfaces.
1376
+
1377
+ Discontinuities in the value of this counter can
1378
+ occur at re-initialization of the management
1379
+ system, and at other times as indicated by the
1380
+ value of ifCounterDiscontinuityTime.""",
1381
+ "reference" :
1382
+ """[IEEE 802.3 Std.], 30.3.4.2,
1383
+ aPAUSEMACCtrlFramesTransmitted.""",
1384
+ }, # column
1385
+ "dot3HCInPauseFrames" : {
1386
+ "nodetype" : "column",
1387
+ "moduleName" : "EtherLike-MIB",
1388
+ "oid" : "1.3.6.1.2.1.10.7.10.1.5",
1389
+ "status" : "current",
1390
+ "syntax" : {
1391
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter64"},
1392
+ },
1393
+ "access" : "readonly",
1394
+ "description" :
1395
+ """A count of MAC Control frames received on this
1396
+ interface with an opcode indicating the PAUSE
1397
+ operation.
1398
+
1399
+ This counter does not increment when the
1400
+ interface is operating in half-duplex mode.
1401
+
1402
+ This counter is a 64 bit version of
1403
+ dot3InPauseFrames. It should be used on
1404
+ interfaces operating at 10 Gb/s or faster.
1405
+
1406
+ Discontinuities in the value of this counter can
1407
+ occur at re-initialization of the management
1408
+ system, and at other times as indicated by the
1409
+ value of ifCounterDiscontinuityTime.""",
1410
+ "reference" :
1411
+ """[IEEE 802.3 Std.], 30.3.4.3,
1412
+ aPAUSEMACCtrlFramesReceived.""",
1413
+ }, # column
1414
+ "dot3HCOutPauseFrames" : {
1415
+ "nodetype" : "column",
1416
+ "moduleName" : "EtherLike-MIB",
1417
+ "oid" : "1.3.6.1.2.1.10.7.10.1.6",
1418
+ "status" : "current",
1419
+ "syntax" : {
1420
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter64"},
1421
+ },
1422
+ "access" : "readonly",
1423
+ "description" :
1424
+ """A count of MAC Control frames transmitted on
1425
+ this interface with an opcode indicating the
1426
+ PAUSE operation.
1427
+
1428
+ This counter does not increment when the
1429
+ interface is operating in half-duplex mode.
1430
+
1431
+ This counter is a 64 bit version of
1432
+ dot3OutPauseFrames. It should be used on
1433
+ interfaces operating at 10 Gb/s or faster.
1434
+
1435
+ Discontinuities in the value of this counter can
1436
+ occur at re-initialization of the management
1437
+ system, and at other times as indicated by the
1438
+ value of ifCounterDiscontinuityTime.""",
1439
+ "reference" :
1440
+ """[IEEE 802.3 Std.], 30.3.4.2,
1441
+ aPAUSEMACCtrlFramesTransmitted.""",
1442
+ }, # column
1443
+ "dot3HCStatsTable" : {
1444
+ "nodetype" : "table",
1445
+ "moduleName" : "EtherLike-MIB",
1446
+ "oid" : "1.3.6.1.2.1.10.7.11",
1447
+ "status" : "current",
1448
+ "description" :
1449
+ """A table containing 64-bit versions of error
1450
+ counters from the dot3StatsTable. The 32-bit
1451
+ versions of these counters may roll over quite
1452
+ quickly on higher speed ethernet interfaces.
1453
+ The counters that have 64-bit versions in this
1454
+ table are the counters that apply to full-duplex
1455
+ interfaces, since 10 Gb/s and faster
1456
+ ethernet-like interfaces do not support
1457
+ half-duplex, and very few 1000 Mb/s
1458
+ ethernet-like interfaces support half-duplex.
1459
+
1460
+ Entries in this table are recommended for
1461
+ interfaces capable of operating at 1000 Mb/s or
1462
+ faster, and are required for interfaces capable
1463
+ of operating at 10 Gb/s or faster. Lower speed
1464
+ ethernet-like interfaces do not need entries in
1465
+ this table, in which case there may be fewer
1466
+ entries in this table than in the
1467
+ dot3StatsTable. However, implementations
1468
+ containing interfaces with a mix of speeds may
1469
+ choose to implement entries in this table for
1470
+
1471
+
1472
+
1473
+ all ethernet-like interfaces.""",
1474
+ }, # table
1475
+ "dot3HCStatsEntry" : {
1476
+ "nodetype" : "row",
1477
+ "moduleName" : "EtherLike-MIB",
1478
+ "oid" : "1.3.6.1.2.1.10.7.11.1",
1479
+ "status" : "current",
1480
+ "linkage" : [
1481
+ "dot3StatsIndex",
1482
+ ],
1483
+ "description" :
1484
+ """An entry containing 64-bit statistics for a
1485
+ single ethernet-like interface.""",
1486
+ }, # row
1487
+ "dot3HCStatsAlignmentErrors" : {
1488
+ "nodetype" : "column",
1489
+ "moduleName" : "EtherLike-MIB",
1490
+ "oid" : "1.3.6.1.2.1.10.7.11.1.1",
1491
+ "status" : "current",
1492
+ "syntax" : {
1493
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter64"},
1494
+ },
1495
+ "access" : "readonly",
1496
+ "description" :
1497
+ """A count of frames received on a particular
1498
+ interface that are not an integral number of
1499
+ octets in length and do not pass the FCS check.
1500
+
1501
+ The count represented by an instance of this
1502
+ object is incremented when the alignmentError
1503
+ status is returned by the MAC service to the
1504
+ LLC (or other MAC user). Received frames for
1505
+ which multiple error conditions pertain are,
1506
+ according to the conventions of IEEE 802.3
1507
+ Layer Management, counted exclusively according
1508
+ to the error status presented to the LLC.
1509
+
1510
+ This counter does not increment for group
1511
+ encoding schemes greater than 4 bits per group.
1512
+
1513
+ This counter is a 64 bit version of
1514
+ dot3StatsAlignmentErrors. It should be used
1515
+ on interfaces operating at 10 Gb/s or faster.
1516
+
1517
+ Discontinuities in the value of this counter can
1518
+ occur at re-initialization of the management
1519
+
1520
+
1521
+
1522
+ system, and at other times as indicated by the
1523
+ value of ifCounterDiscontinuityTime.""",
1524
+ "reference" :
1525
+ """[IEEE 802.3 Std.], 30.3.1.1.7,
1526
+ aAlignmentErrors""",
1527
+ }, # column
1528
+ "dot3HCStatsFCSErrors" : {
1529
+ "nodetype" : "column",
1530
+ "moduleName" : "EtherLike-MIB",
1531
+ "oid" : "1.3.6.1.2.1.10.7.11.1.2",
1532
+ "status" : "current",
1533
+ "syntax" : {
1534
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter64"},
1535
+ },
1536
+ "access" : "readonly",
1537
+ "description" :
1538
+ """A count of frames received on a particular
1539
+ interface that are an integral number of octets
1540
+ in length but do not pass the FCS check. This
1541
+ count does not include frames received with
1542
+ frame-too-long or frame-too-short error.
1543
+
1544
+ The count represented by an instance of this
1545
+ object is incremented when the frameCheckError
1546
+ status is returned by the MAC service to the
1547
+ LLC (or other MAC user). Received frames for
1548
+ which multiple error conditions pertain are,
1549
+ according to the conventions of IEEE 802.3
1550
+ Layer Management, counted exclusively according
1551
+ to the error status presented to the LLC.
1552
+
1553
+ Note: Coding errors detected by the physical
1554
+ layer for speeds above 10 Mb/s will cause the
1555
+ frame to fail the FCS check.
1556
+
1557
+ This counter is a 64 bit version of
1558
+ dot3StatsFCSErrors. It should be used on
1559
+ interfaces operating at 10 Gb/s or faster.
1560
+
1561
+ Discontinuities in the value of this counter can
1562
+ occur at re-initialization of the management
1563
+ system, and at other times as indicated by the
1564
+ value of ifCounterDiscontinuityTime.""",
1565
+ "reference" :
1566
+ """[IEEE 802.3 Std.], 30.3.1.1.6,
1567
+ aFrameCheckSequenceErrors.""",
1568
+ }, # column
1569
+ "dot3HCStatsInternalMacTransmitErrors" : {
1570
+ "nodetype" : "column",
1571
+ "moduleName" : "EtherLike-MIB",
1572
+ "oid" : "1.3.6.1.2.1.10.7.11.1.3",
1573
+ "status" : "current",
1574
+ "syntax" : {
1575
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter64"},
1576
+ },
1577
+ "access" : "readonly",
1578
+ "description" :
1579
+ """A count of frames for which transmission on a
1580
+ particular interface fails due to an internal
1581
+ MAC sublayer transmit error. A frame is only
1582
+
1583
+
1584
+
1585
+ counted by an instance of this object if it is
1586
+ not counted by the corresponding instance of
1587
+ either the dot3StatsLateCollisions object, the
1588
+ dot3StatsExcessiveCollisions object, or the
1589
+ dot3StatsCarrierSenseErrors object.
1590
+
1591
+ The precise meaning of the count represented by
1592
+ an instance of this object is implementation-
1593
+ specific. In particular, an instance of this
1594
+ object may represent a count of transmission
1595
+ errors on a particular interface that are not
1596
+ otherwise counted.
1597
+
1598
+ This counter is a 64 bit version of
1599
+ dot3StatsInternalMacTransmitErrors. It should
1600
+ be used on interfaces operating at 10 Gb/s or
1601
+ faster.
1602
+
1603
+ Discontinuities in the value of this counter can
1604
+ occur at re-initialization of the management
1605
+ system, and at other times as indicated by the
1606
+ value of ifCounterDiscontinuityTime.""",
1607
+ "reference" :
1608
+ """[IEEE 802.3 Std.], 30.3.1.1.12,
1609
+ aFramesLostDueToIntMACXmitError.""",
1610
+ }, # column
1611
+ "dot3HCStatsFrameTooLongs" : {
1612
+ "nodetype" : "column",
1613
+ "moduleName" : "EtherLike-MIB",
1614
+ "oid" : "1.3.6.1.2.1.10.7.11.1.4",
1615
+ "status" : "current",
1616
+ "syntax" : {
1617
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter64"},
1618
+ },
1619
+ "access" : "readonly",
1620
+ "description" :
1621
+ """A count of frames received on a particular
1622
+ interface that exceed the maximum permitted
1623
+ frame size.
1624
+
1625
+ The count represented by an instance of this
1626
+ object is incremented when the frameTooLong
1627
+ status is returned by the MAC service to the
1628
+ LLC (or other MAC user). Received frames for
1629
+ which multiple error conditions pertain are,
1630
+ according to the conventions of IEEE 802.3
1631
+ Layer Management, counted exclusively according
1632
+ to the error status presented to the LLC.
1633
+
1634
+ This counter is a 64 bit version of
1635
+ dot3StatsFrameTooLongs. It should be used on
1636
+ interfaces operating at 10 Gb/s or faster.
1637
+
1638
+ Discontinuities in the value of this counter can
1639
+
1640
+
1641
+
1642
+ occur at re-initialization of the management
1643
+ system, and at other times as indicated by the
1644
+ value of ifCounterDiscontinuityTime.""",
1645
+ "reference" :
1646
+ """[IEEE 802.3 Std.], 30.3.1.1.25,
1647
+ aFrameTooLongErrors.""",
1648
+ }, # column
1649
+ "dot3HCStatsInternalMacReceiveErrors" : {
1650
+ "nodetype" : "column",
1651
+ "moduleName" : "EtherLike-MIB",
1652
+ "oid" : "1.3.6.1.2.1.10.7.11.1.5",
1653
+ "status" : "current",
1654
+ "syntax" : {
1655
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter64"},
1656
+ },
1657
+ "access" : "readonly",
1658
+ "description" :
1659
+ """A count of frames for which reception on a
1660
+ particular interface fails due to an internal
1661
+ MAC sublayer receive error. A frame is only
1662
+ counted by an instance of this object if it is
1663
+ not counted by the corresponding instance of
1664
+ either the dot3StatsFrameTooLongs object, the
1665
+ dot3StatsAlignmentErrors object, or the
1666
+ dot3StatsFCSErrors object.
1667
+
1668
+ The precise meaning of the count represented by
1669
+ an instance of this object is implementation-
1670
+ specific. In particular, an instance of this
1671
+ object may represent a count of receive errors
1672
+ on a particular interface that are not
1673
+ otherwise counted.
1674
+
1675
+ This counter is a 64 bit version of
1676
+ dot3StatsInternalMacReceiveErrors. It should be
1677
+ used on interfaces operating at 10 Gb/s or
1678
+ faster.
1679
+
1680
+ Discontinuities in the value of this counter can
1681
+ occur at re-initialization of the management
1682
+ system, and at other times as indicated by the
1683
+ value of ifCounterDiscontinuityTime.""",
1684
+ "reference" :
1685
+ """[IEEE 802.3 Std.], 30.3.1.1.15,
1686
+ aFramesLostDueToIntMACRcvError.""",
1687
+ }, # column
1688
+ "dot3HCStatsSymbolErrors" : {
1689
+ "nodetype" : "column",
1690
+ "moduleName" : "EtherLike-MIB",
1691
+ "oid" : "1.3.6.1.2.1.10.7.11.1.6",
1692
+ "status" : "current",
1693
+ "syntax" : {
1694
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter64"},
1695
+ },
1696
+ "access" : "readonly",
1697
+ "description" :
1698
+ """For an interface operating at 100 Mb/s, the
1699
+ number of times there was an invalid data symbol
1700
+ when a valid carrier was present.
1701
+
1702
+
1703
+
1704
+
1705
+ For an interface operating in half-duplex mode
1706
+ at 1000 Mb/s, the number of times the receiving
1707
+ media is non-idle (a carrier event) for a period
1708
+ of time equal to or greater than slotTime, and
1709
+ during which there was at least one occurrence
1710
+ of an event that causes the PHY to indicate
1711
+ 'Data reception error' or 'carrier extend error'
1712
+ on the GMII.
1713
+
1714
+ For an interface operating in full-duplex mode
1715
+ at 1000 Mb/s, the number of times the receiving
1716
+ media is non-idle (a carrier event) for a period
1717
+ of time equal to or greater than minFrameSize,
1718
+ and during which there was at least one
1719
+ occurrence of an event that causes the PHY to
1720
+ indicate 'Data reception error' on the GMII.
1721
+
1722
+ For an interface operating at 10 Gb/s, the
1723
+ number of times the receiving media is non-idle
1724
+ (a carrier event) for a period of time equal to
1725
+ or greater than minFrameSize, and during which
1726
+ there was at least one occurrence of an event
1727
+ that causes the PHY to indicate 'Receive Error'
1728
+ on the XGMII.
1729
+
1730
+ The count represented by an instance of this
1731
+ object is incremented at most once per carrier
1732
+ event, even if multiple symbol errors occur
1733
+ during the carrier event. This count does
1734
+ not increment if a collision is present.
1735
+
1736
+ This counter is a 64 bit version of
1737
+ dot3StatsSymbolErrors. It should be used on
1738
+ interfaces operating at 10 Gb/s or faster.
1739
+
1740
+ Discontinuities in the value of this counter can
1741
+ occur at re-initialization of the management
1742
+ system, and at other times as indicated by the
1743
+ value of ifCounterDiscontinuityTime.""",
1744
+ "reference" :
1745
+ """[IEEE 802.3 Std.], 30.3.2.1.5,
1746
+ aSymbolErrorDuringCarrier.""",
1747
+ }, # column
1748
+ "etherMIB" : {
1749
+ "nodetype" : "node",
1750
+ "moduleName" : "EtherLike-MIB",
1751
+ "oid" : "1.3.6.1.2.1.35",
1752
+ "status" : "current",
1753
+ }, # node
1754
+ "etherMIBObjects" : {
1755
+ "nodetype" : "node",
1756
+ "moduleName" : "EtherLike-MIB",
1757
+ "oid" : "1.3.6.1.2.1.35.1",
1758
+ }, # node
1759
+ "etherConformance" : {
1760
+ "nodetype" : "node",
1761
+ "moduleName" : "EtherLike-MIB",
1762
+ "oid" : "1.3.6.1.2.1.35.2",
1763
+ }, # node
1764
+ "etherGroups" : {
1765
+ "nodetype" : "node",
1766
+ "moduleName" : "EtherLike-MIB",
1767
+ "oid" : "1.3.6.1.2.1.35.2.1",
1768
+ }, # node
1769
+ "etherCompliances" : {
1770
+ "nodetype" : "node",
1771
+ "moduleName" : "EtherLike-MIB",
1772
+ "oid" : "1.3.6.1.2.1.35.2.2",
1773
+ }, # node
1774
+ }, # nodes
1775
+
1776
+ "groups" : {
1777
+ "etherStatsGroup" : {
1778
+ "nodetype" : "group",
1779
+ "moduleName" : "EtherLike-MIB",
1780
+ "oid" : "1.3.6.1.2.1.35.2.1.1",
1781
+ "status" : "deprecated",
1782
+ "members" : {
1783
+ "dot3StatsIndex" : {
1784
+ "nodetype" : "member",
1785
+ "module" : "EtherLike-MIB"
1786
+ },
1787
+ "dot3StatsAlignmentErrors" : {
1788
+ "nodetype" : "member",
1789
+ "module" : "EtherLike-MIB"
1790
+ },
1791
+ "dot3StatsFCSErrors" : {
1792
+ "nodetype" : "member",
1793
+ "module" : "EtherLike-MIB"
1794
+ },
1795
+ "dot3StatsSingleCollisionFrames" : {
1796
+ "nodetype" : "member",
1797
+ "module" : "EtherLike-MIB"
1798
+ },
1799
+ "dot3StatsMultipleCollisionFrames" : {
1800
+ "nodetype" : "member",
1801
+ "module" : "EtherLike-MIB"
1802
+ },
1803
+ "dot3StatsSQETestErrors" : {
1804
+ "nodetype" : "member",
1805
+ "module" : "EtherLike-MIB"
1806
+ },
1807
+ "dot3StatsDeferredTransmissions" : {
1808
+ "nodetype" : "member",
1809
+ "module" : "EtherLike-MIB"
1810
+ },
1811
+ "dot3StatsLateCollisions" : {
1812
+ "nodetype" : "member",
1813
+ "module" : "EtherLike-MIB"
1814
+ },
1815
+ "dot3StatsExcessiveCollisions" : {
1816
+ "nodetype" : "member",
1817
+ "module" : "EtherLike-MIB"
1818
+ },
1819
+ "dot3StatsInternalMacTransmitErrors" : {
1820
+ "nodetype" : "member",
1821
+ "module" : "EtherLike-MIB"
1822
+ },
1823
+ "dot3StatsCarrierSenseErrors" : {
1824
+ "nodetype" : "member",
1825
+ "module" : "EtherLike-MIB"
1826
+ },
1827
+ "dot3StatsFrameTooLongs" : {
1828
+ "nodetype" : "member",
1829
+ "module" : "EtherLike-MIB"
1830
+ },
1831
+ "dot3StatsInternalMacReceiveErrors" : {
1832
+ "nodetype" : "member",
1833
+ "module" : "EtherLike-MIB"
1834
+ },
1835
+ "dot3StatsEtherChipSet" : {
1836
+ "nodetype" : "member",
1837
+ "module" : "EtherLike-MIB"
1838
+ },
1839
+ }, # members
1840
+ "description" :
1841
+ """********* THIS GROUP IS DEPRECATED **********
1842
+
1843
+ A collection of objects providing information
1844
+ applicable to all ethernet-like network
1845
+ interfaces.
1846
+
1847
+ This object group has been deprecated and
1848
+ replaced by etherStatsBaseGroup and
1849
+ etherStatsLowSpeedGroup.""",
1850
+ }, # group
1851
+ "etherCollisionTableGroup" : {
1852
+ "nodetype" : "group",
1853
+ "moduleName" : "EtherLike-MIB",
1854
+ "oid" : "1.3.6.1.2.1.35.2.1.2",
1855
+ "status" : "current",
1856
+ "members" : {
1857
+ "dot3CollFrequencies" : {
1858
+ "nodetype" : "member",
1859
+ "module" : "EtherLike-MIB"
1860
+ },
1861
+ }, # members
1862
+ "description" :
1863
+ """A collection of objects providing a histogram
1864
+ of packets successfully transmitted after
1865
+ experiencing exactly N collisions.""",
1866
+ }, # group
1867
+ "etherStats100MbsGroup" : {
1868
+ "nodetype" : "group",
1869
+ "moduleName" : "EtherLike-MIB",
1870
+ "oid" : "1.3.6.1.2.1.35.2.1.3",
1871
+ "status" : "deprecated",
1872
+ "members" : {
1873
+ "dot3StatsIndex" : {
1874
+ "nodetype" : "member",
1875
+ "module" : "EtherLike-MIB"
1876
+ },
1877
+ "dot3StatsAlignmentErrors" : {
1878
+ "nodetype" : "member",
1879
+ "module" : "EtherLike-MIB"
1880
+ },
1881
+ "dot3StatsFCSErrors" : {
1882
+ "nodetype" : "member",
1883
+ "module" : "EtherLike-MIB"
1884
+ },
1885
+ "dot3StatsSingleCollisionFrames" : {
1886
+ "nodetype" : "member",
1887
+ "module" : "EtherLike-MIB"
1888
+ },
1889
+ "dot3StatsMultipleCollisionFrames" : {
1890
+ "nodetype" : "member",
1891
+ "module" : "EtherLike-MIB"
1892
+ },
1893
+ "dot3StatsDeferredTransmissions" : {
1894
+ "nodetype" : "member",
1895
+ "module" : "EtherLike-MIB"
1896
+ },
1897
+ "dot3StatsLateCollisions" : {
1898
+ "nodetype" : "member",
1899
+ "module" : "EtherLike-MIB"
1900
+ },
1901
+ "dot3StatsExcessiveCollisions" : {
1902
+ "nodetype" : "member",
1903
+ "module" : "EtherLike-MIB"
1904
+ },
1905
+ "dot3StatsInternalMacTransmitErrors" : {
1906
+ "nodetype" : "member",
1907
+ "module" : "EtherLike-MIB"
1908
+ },
1909
+ "dot3StatsCarrierSenseErrors" : {
1910
+ "nodetype" : "member",
1911
+ "module" : "EtherLike-MIB"
1912
+ },
1913
+ "dot3StatsFrameTooLongs" : {
1914
+ "nodetype" : "member",
1915
+ "module" : "EtherLike-MIB"
1916
+ },
1917
+ "dot3StatsInternalMacReceiveErrors" : {
1918
+ "nodetype" : "member",
1919
+ "module" : "EtherLike-MIB"
1920
+ },
1921
+ "dot3StatsEtherChipSet" : {
1922
+ "nodetype" : "member",
1923
+ "module" : "EtherLike-MIB"
1924
+ },
1925
+ "dot3StatsSymbolErrors" : {
1926
+ "nodetype" : "member",
1927
+ "module" : "EtherLike-MIB"
1928
+ },
1929
+ }, # members
1930
+ "description" :
1931
+ """********* THIS GROUP IS DEPRECATED **********
1932
+
1933
+ A collection of objects providing information
1934
+ applicable to 100 Mb/sec ethernet-like network
1935
+ interfaces.
1936
+
1937
+ This object group has been deprecated and
1938
+ replaced by etherStatsBaseGroup and
1939
+ etherStatsHighSpeedGroup.""",
1940
+ }, # group
1941
+ "etherStatsBaseGroup" : {
1942
+ "nodetype" : "group",
1943
+ "moduleName" : "EtherLike-MIB",
1944
+ "oid" : "1.3.6.1.2.1.35.2.1.4",
1945
+ "status" : "deprecated",
1946
+ "members" : {
1947
+ "dot3StatsIndex" : {
1948
+ "nodetype" : "member",
1949
+ "module" : "EtherLike-MIB"
1950
+ },
1951
+ "dot3StatsAlignmentErrors" : {
1952
+ "nodetype" : "member",
1953
+ "module" : "EtherLike-MIB"
1954
+ },
1955
+ "dot3StatsFCSErrors" : {
1956
+ "nodetype" : "member",
1957
+ "module" : "EtherLike-MIB"
1958
+ },
1959
+ "dot3StatsSingleCollisionFrames" : {
1960
+ "nodetype" : "member",
1961
+ "module" : "EtherLike-MIB"
1962
+ },
1963
+ "dot3StatsMultipleCollisionFrames" : {
1964
+ "nodetype" : "member",
1965
+ "module" : "EtherLike-MIB"
1966
+ },
1967
+ "dot3StatsDeferredTransmissions" : {
1968
+ "nodetype" : "member",
1969
+ "module" : "EtherLike-MIB"
1970
+ },
1971
+ "dot3StatsLateCollisions" : {
1972
+ "nodetype" : "member",
1973
+ "module" : "EtherLike-MIB"
1974
+ },
1975
+ "dot3StatsExcessiveCollisions" : {
1976
+ "nodetype" : "member",
1977
+ "module" : "EtherLike-MIB"
1978
+ },
1979
+ "dot3StatsInternalMacTransmitErrors" : {
1980
+ "nodetype" : "member",
1981
+ "module" : "EtherLike-MIB"
1982
+ },
1983
+ "dot3StatsCarrierSenseErrors" : {
1984
+ "nodetype" : "member",
1985
+ "module" : "EtherLike-MIB"
1986
+ },
1987
+ "dot3StatsFrameTooLongs" : {
1988
+ "nodetype" : "member",
1989
+ "module" : "EtherLike-MIB"
1990
+ },
1991
+ "dot3StatsInternalMacReceiveErrors" : {
1992
+ "nodetype" : "member",
1993
+ "module" : "EtherLike-MIB"
1994
+ },
1995
+ }, # members
1996
+ "description" :
1997
+ """********* THIS GROUP IS DEPRECATED **********
1998
+
1999
+ A collection of objects providing information
2000
+ applicable to all ethernet-like network
2001
+ interfaces.
2002
+
2003
+ This object group has been deprecated and
2004
+ replaced by etherStatsBaseGroup2 and
2005
+ etherStatsHalfDuplexGroup, to separate
2006
+ objects which must be implemented by all
2007
+ ethernet-like network interfaces from
2008
+ objects that need only be implemented on
2009
+ ethernet-like network interfaces that are
2010
+ capable of half-duplex operation.""",
2011
+ }, # group
2012
+ "etherStatsLowSpeedGroup" : {
2013
+ "nodetype" : "group",
2014
+ "moduleName" : "EtherLike-MIB",
2015
+ "oid" : "1.3.6.1.2.1.35.2.1.5",
2016
+ "status" : "current",
2017
+ "members" : {
2018
+ "dot3StatsSQETestErrors" : {
2019
+ "nodetype" : "member",
2020
+ "module" : "EtherLike-MIB"
2021
+ },
2022
+ }, # members
2023
+ "description" :
2024
+ """A collection of objects providing information
2025
+
2026
+
2027
+
2028
+ applicable to ethernet-like network interfaces
2029
+ capable of operating at 10 Mb/s or slower in
2030
+ half-duplex mode.""",
2031
+ }, # group
2032
+ "etherStatsHighSpeedGroup" : {
2033
+ "nodetype" : "group",
2034
+ "moduleName" : "EtherLike-MIB",
2035
+ "oid" : "1.3.6.1.2.1.35.2.1.6",
2036
+ "status" : "current",
2037
+ "members" : {
2038
+ "dot3StatsSymbolErrors" : {
2039
+ "nodetype" : "member",
2040
+ "module" : "EtherLike-MIB"
2041
+ },
2042
+ }, # members
2043
+ "description" :
2044
+ """A collection of objects providing information
2045
+ applicable to ethernet-like network interfaces
2046
+ capable of operating at 100 Mb/s or faster.""",
2047
+ }, # group
2048
+ "etherDuplexGroup" : {
2049
+ "nodetype" : "group",
2050
+ "moduleName" : "EtherLike-MIB",
2051
+ "oid" : "1.3.6.1.2.1.35.2.1.7",
2052
+ "status" : "current",
2053
+ "members" : {
2054
+ "dot3StatsDuplexStatus" : {
2055
+ "nodetype" : "member",
2056
+ "module" : "EtherLike-MIB"
2057
+ },
2058
+ }, # members
2059
+ "description" :
2060
+ """A collection of objects providing information
2061
+ about the duplex mode of an ethernet-like
2062
+ network interface.""",
2063
+ }, # group
2064
+ "etherControlGroup" : {
2065
+ "nodetype" : "group",
2066
+ "moduleName" : "EtherLike-MIB",
2067
+ "oid" : "1.3.6.1.2.1.35.2.1.8",
2068
+ "status" : "current",
2069
+ "members" : {
2070
+ "dot3ControlFunctionsSupported" : {
2071
+ "nodetype" : "member",
2072
+ "module" : "EtherLike-MIB"
2073
+ },
2074
+ "dot3ControlInUnknownOpcodes" : {
2075
+ "nodetype" : "member",
2076
+ "module" : "EtherLike-MIB"
2077
+ },
2078
+ }, # members
2079
+ "description" :
2080
+ """A collection of objects providing information
2081
+ about the MAC Control sublayer on ethernet-like
2082
+ network interfaces.""",
2083
+ }, # group
2084
+ "etherControlPauseGroup" : {
2085
+ "nodetype" : "group",
2086
+ "moduleName" : "EtherLike-MIB",
2087
+ "oid" : "1.3.6.1.2.1.35.2.1.9",
2088
+ "status" : "current",
2089
+ "members" : {
2090
+ "dot3PauseAdminMode" : {
2091
+ "nodetype" : "member",
2092
+ "module" : "EtherLike-MIB"
2093
+ },
2094
+ "dot3PauseOperMode" : {
2095
+ "nodetype" : "member",
2096
+ "module" : "EtherLike-MIB"
2097
+ },
2098
+ "dot3InPauseFrames" : {
2099
+ "nodetype" : "member",
2100
+ "module" : "EtherLike-MIB"
2101
+ },
2102
+ "dot3OutPauseFrames" : {
2103
+ "nodetype" : "member",
2104
+ "module" : "EtherLike-MIB"
2105
+ },
2106
+ }, # members
2107
+ "description" :
2108
+ """A collection of objects providing information
2109
+ about and control of the MAC Control PAUSE
2110
+ function on ethernet-like network interfaces.""",
2111
+ }, # group
2112
+ "etherStatsBaseGroup2" : {
2113
+ "nodetype" : "group",
2114
+ "moduleName" : "EtherLike-MIB",
2115
+ "oid" : "1.3.6.1.2.1.35.2.1.10",
2116
+ "status" : "current",
2117
+ "members" : {
2118
+ "dot3StatsIndex" : {
2119
+ "nodetype" : "member",
2120
+ "module" : "EtherLike-MIB"
2121
+ },
2122
+ "dot3StatsAlignmentErrors" : {
2123
+ "nodetype" : "member",
2124
+ "module" : "EtherLike-MIB"
2125
+ },
2126
+ "dot3StatsFCSErrors" : {
2127
+ "nodetype" : "member",
2128
+ "module" : "EtherLike-MIB"
2129
+ },
2130
+ "dot3StatsInternalMacTransmitErrors" : {
2131
+ "nodetype" : "member",
2132
+ "module" : "EtherLike-MIB"
2133
+ },
2134
+ "dot3StatsFrameTooLongs" : {
2135
+ "nodetype" : "member",
2136
+ "module" : "EtherLike-MIB"
2137
+ },
2138
+ "dot3StatsInternalMacReceiveErrors" : {
2139
+ "nodetype" : "member",
2140
+ "module" : "EtherLike-MIB"
2141
+ },
2142
+ }, # members
2143
+ "description" :
2144
+ """A collection of objects providing information
2145
+ applicable to all ethernet-like network
2146
+ interfaces.""",
2147
+ }, # group
2148
+ "etherStatsHalfDuplexGroup" : {
2149
+ "nodetype" : "group",
2150
+ "moduleName" : "EtherLike-MIB",
2151
+ "oid" : "1.3.6.1.2.1.35.2.1.11",
2152
+ "status" : "current",
2153
+ "members" : {
2154
+ "dot3StatsSingleCollisionFrames" : {
2155
+ "nodetype" : "member",
2156
+ "module" : "EtherLike-MIB"
2157
+ },
2158
+ "dot3StatsMultipleCollisionFrames" : {
2159
+ "nodetype" : "member",
2160
+ "module" : "EtherLike-MIB"
2161
+ },
2162
+ "dot3StatsDeferredTransmissions" : {
2163
+ "nodetype" : "member",
2164
+ "module" : "EtherLike-MIB"
2165
+ },
2166
+ "dot3StatsLateCollisions" : {
2167
+ "nodetype" : "member",
2168
+ "module" : "EtherLike-MIB"
2169
+ },
2170
+ "dot3StatsExcessiveCollisions" : {
2171
+ "nodetype" : "member",
2172
+ "module" : "EtherLike-MIB"
2173
+ },
2174
+ "dot3StatsCarrierSenseErrors" : {
2175
+ "nodetype" : "member",
2176
+ "module" : "EtherLike-MIB"
2177
+ },
2178
+ }, # members
2179
+ "description" :
2180
+ """A collection of objects providing information
2181
+ applicable only to half-duplex ethernet-like
2182
+ network interfaces.""",
2183
+ }, # group
2184
+ "etherHCStatsGroup" : {
2185
+ "nodetype" : "group",
2186
+ "moduleName" : "EtherLike-MIB",
2187
+ "oid" : "1.3.6.1.2.1.35.2.1.12",
2188
+ "status" : "current",
2189
+ "members" : {
2190
+ "dot3HCStatsAlignmentErrors" : {
2191
+ "nodetype" : "member",
2192
+ "module" : "EtherLike-MIB"
2193
+ },
2194
+ "dot3HCStatsFCSErrors" : {
2195
+ "nodetype" : "member",
2196
+ "module" : "EtherLike-MIB"
2197
+ },
2198
+ "dot3HCStatsInternalMacTransmitErrors" : {
2199
+ "nodetype" : "member",
2200
+ "module" : "EtherLike-MIB"
2201
+ },
2202
+ "dot3HCStatsFrameTooLongs" : {
2203
+ "nodetype" : "member",
2204
+ "module" : "EtherLike-MIB"
2205
+ },
2206
+ "dot3HCStatsInternalMacReceiveErrors" : {
2207
+ "nodetype" : "member",
2208
+ "module" : "EtherLike-MIB"
2209
+ },
2210
+ "dot3HCStatsSymbolErrors" : {
2211
+ "nodetype" : "member",
2212
+ "module" : "EtherLike-MIB"
2213
+ },
2214
+ }, # members
2215
+ "description" :
2216
+ """A collection of objects providing high-capacity
2217
+ statistics applicable to higher-speed
2218
+ ethernet-like network interfaces.""",
2219
+ }, # group
2220
+ "etherHCControlGroup" : {
2221
+ "nodetype" : "group",
2222
+ "moduleName" : "EtherLike-MIB",
2223
+ "oid" : "1.3.6.1.2.1.35.2.1.13",
2224
+ "status" : "current",
2225
+ "members" : {
2226
+ "dot3HCControlInUnknownOpcodes" : {
2227
+ "nodetype" : "member",
2228
+ "module" : "EtherLike-MIB"
2229
+ },
2230
+ }, # members
2231
+ "description" :
2232
+ """A collection of objects providing high-capacity
2233
+ statistics for the MAC Control sublayer on
2234
+ higher-speed ethernet-like network interfaces.""",
2235
+ }, # group
2236
+ "etherHCControlPauseGroup" : {
2237
+ "nodetype" : "group",
2238
+ "moduleName" : "EtherLike-MIB",
2239
+ "oid" : "1.3.6.1.2.1.35.2.1.14",
2240
+ "status" : "current",
2241
+ "members" : {
2242
+ "dot3HCInPauseFrames" : {
2243
+ "nodetype" : "member",
2244
+ "module" : "EtherLike-MIB"
2245
+ },
2246
+ "dot3HCOutPauseFrames" : {
2247
+ "nodetype" : "member",
2248
+ "module" : "EtherLike-MIB"
2249
+ },
2250
+ }, # members
2251
+ "description" :
2252
+ """A collection of objects providing high-capacity
2253
+ statistics for the MAC Control PAUSE function on
2254
+ higher-speed ethernet-like network interfaces.""",
2255
+ }, # group
2256
+ "etherRateControlGroup" : {
2257
+ "nodetype" : "group",
2258
+ "moduleName" : "EtherLike-MIB",
2259
+ "oid" : "1.3.6.1.2.1.35.2.1.15",
2260
+ "status" : "current",
2261
+ "members" : {
2262
+ "dot3StatsRateControlAbility" : {
2263
+ "nodetype" : "member",
2264
+ "module" : "EtherLike-MIB"
2265
+ },
2266
+ "dot3StatsRateControlStatus" : {
2267
+ "nodetype" : "member",
2268
+ "module" : "EtherLike-MIB"
2269
+ },
2270
+ }, # members
2271
+ "description" :
2272
+ """A collection of objects providing information
2273
+ about the Rate Control function on ethernet-like
2274
+ interfaces.""",
2275
+ }, # group
2276
+ }, # groups
2277
+
2278
+ "compliances" : {
2279
+ "etherCompliance" : {
2280
+ "nodetype" : "compliance",
2281
+ "moduleName" : "EtherLike-MIB",
2282
+ "oid" : "1.3.6.1.2.1.35.2.2.1",
2283
+ "status" : "deprecated",
2284
+ "description" :
2285
+ """******** THIS COMPLIANCE IS DEPRECATED ********
2286
+
2287
+ The compliance statement for managed network
2288
+ entities which have ethernet-like network
2289
+ interfaces.
2290
+
2291
+ This compliance is deprecated and replaced by
2292
+ dot3Compliance.""",
2293
+ "requires" : {
2294
+ "etherStatsGroup" : {
2295
+ "nodetype" : "mandatory",
2296
+ "module" : "EtherLike-MIB"
2297
+ },
2298
+ "etherCollisionTableGroup" : {
2299
+ "nodetype" : "optional",
2300
+ "module" : "EtherLike-MIB",
2301
+ "description" :
2302
+ """This group is optional. It is appropriate
2303
+ for all systems which have the necessary
2304
+ metering. Implementation in such systems is
2305
+ highly recommended.""",
2306
+ },
2307
+ }, # requires
2308
+ }, # compliance
2309
+ "ether100MbsCompliance" : {
2310
+ "nodetype" : "compliance",
2311
+ "moduleName" : "EtherLike-MIB",
2312
+ "oid" : "1.3.6.1.2.1.35.2.2.2",
2313
+ "status" : "deprecated",
2314
+ "description" :
2315
+ """******** THIS COMPLIANCE IS DEPRECATED ********
2316
+
2317
+ The compliance statement for managed network
2318
+ entities which have 100 Mb/sec ethernet-like
2319
+ network interfaces.
2320
+
2321
+ This compliance is deprecated and replaced by
2322
+ dot3Compliance.""",
2323
+ "requires" : {
2324
+ "etherStats100MbsGroup" : {
2325
+ "nodetype" : "mandatory",
2326
+ "module" : "EtherLike-MIB"
2327
+ },
2328
+ "etherCollisionTableGroup" : {
2329
+ "nodetype" : "optional",
2330
+ "module" : "EtherLike-MIB",
2331
+ "description" :
2332
+ """This group is optional. It is appropriate
2333
+ for all systems which have the necessary
2334
+ metering. Implementation in such systems is
2335
+ highly recommended.""",
2336
+ },
2337
+ }, # requires
2338
+ }, # compliance
2339
+ "dot3Compliance" : {
2340
+ "nodetype" : "compliance",
2341
+ "moduleName" : "EtherLike-MIB",
2342
+ "oid" : "1.3.6.1.2.1.35.2.2.3",
2343
+ "status" : "deprecated",
2344
+ "description" :
2345
+ """******** THIS COMPLIANCE IS DEPRECATED ********
2346
+
2347
+ The compliance statement for managed network
2348
+ entities which have ethernet-like network
2349
+ interfaces.
2350
+
2351
+ This compliance is deprecated and replaced by
2352
+ dot3Compliance2.""",
2353
+ "requires" : {
2354
+ "etherStatsBaseGroup" : {
2355
+ "nodetype" : "mandatory",
2356
+ "module" : "EtherLike-MIB"
2357
+ },
2358
+ "etherDuplexGroup" : {
2359
+ "nodetype" : "optional",
2360
+ "module" : "EtherLike-MIB",
2361
+ "description" :
2362
+ """This group is mandatory for all
2363
+ ethernet-like network interfaces which are
2364
+ capable of operating in full-duplex mode.
2365
+ It is highly recommended for all
2366
+ ethernet-like network interfaces.""",
2367
+ },
2368
+ "etherStatsLowSpeedGroup" : {
2369
+ "nodetype" : "optional",
2370
+ "module" : "EtherLike-MIB",
2371
+ "description" :
2372
+ """This group is mandatory for all
2373
+ ethernet-like network interfaces which are
2374
+ capable of operating at 10 Mb/s or slower in
2375
+ half-duplex mode.""",
2376
+ },
2377
+ "etherStatsHighSpeedGroup" : {
2378
+ "nodetype" : "optional",
2379
+ "module" : "EtherLike-MIB",
2380
+ "description" :
2381
+ """This group is mandatory for all
2382
+ ethernet-like network interfaces which are
2383
+ capable of operating at 100 Mb/s or faster.""",
2384
+ },
2385
+ "etherControlGroup" : {
2386
+ "nodetype" : "optional",
2387
+ "module" : "EtherLike-MIB",
2388
+ "description" :
2389
+ """This group is mandatory for all
2390
+ ethernet-like network interfaces that
2391
+ support the MAC Control sublayer.""",
2392
+ },
2393
+ "etherControlPauseGroup" : {
2394
+ "nodetype" : "optional",
2395
+ "module" : "EtherLike-MIB",
2396
+ "description" :
2397
+ """This group is mandatory for all
2398
+ ethernet-like network interfaces that
2399
+ support the MAC Control PAUSE function.""",
2400
+ },
2401
+ "etherCollisionTableGroup" : {
2402
+ "nodetype" : "optional",
2403
+ "module" : "EtherLike-MIB",
2404
+ "description" :
2405
+ """This group is optional. It is appropriate
2406
+ for all ethernet-like network interfaces
2407
+ which are capable of operating in
2408
+ half-duplex mode and have the necessary
2409
+ metering. Implementation in systems with
2410
+
2411
+
2412
+
2413
+ such interfaces is highly recommended.""",
2414
+ },
2415
+ }, # requires
2416
+ }, # compliance
2417
+ "dot3Compliance2" : {
2418
+ "nodetype" : "compliance",
2419
+ "moduleName" : "EtherLike-MIB",
2420
+ "oid" : "1.3.6.1.2.1.35.2.2.4",
2421
+ "status" : "current",
2422
+ "description" :
2423
+ """The compliance statement for managed network
2424
+ entities which have ethernet-like network
2425
+ interfaces.
2426
+
2427
+ Note that compliance with this MIB module
2428
+ requires compliance with the ifCompliance3
2429
+ MODULE-COMPLIANCE statement of the IF-MIB
2430
+ (RFC2863). In addition, compliance with this
2431
+ MIB module requires compliance with the
2432
+ mauModIfCompl3 MODULE-COMPLIANCE statement of
2433
+ the MAU-MIB (RFC3636).""",
2434
+ "requires" : {
2435
+ "etherStatsBaseGroup2" : {
2436
+ "nodetype" : "mandatory",
2437
+ "module" : "EtherLike-MIB"
2438
+ },
2439
+ "etherDuplexGroup" : {
2440
+ "nodetype" : "optional",
2441
+ "module" : "EtherLike-MIB",
2442
+ "description" :
2443
+ """This group is mandatory for all
2444
+ ethernet-like network interfaces which are
2445
+ capable of operating in full-duplex mode.
2446
+ It is highly recommended for all
2447
+ ethernet-like network interfaces.""",
2448
+ },
2449
+ "etherRateControlGroup" : {
2450
+ "nodetype" : "optional",
2451
+ "module" : "EtherLike-MIB",
2452
+ "description" :
2453
+ """This group is mandatory for all
2454
+ ethernet-like network interfaces which are
2455
+ capable of operating at speeds faster than
2456
+ 1000 Mb/s. It is highly recommended for all
2457
+ ethernet-like network interfaces.""",
2458
+ },
2459
+ "etherStatsLowSpeedGroup" : {
2460
+ "nodetype" : "optional",
2461
+ "module" : "EtherLike-MIB",
2462
+ "description" :
2463
+ """This group is mandatory for all
2464
+ ethernet-like network interfaces which are
2465
+ capable of operating at 10 Mb/s or slower in
2466
+ half-duplex mode.""",
2467
+ },
2468
+ "etherStatsHighSpeedGroup" : {
2469
+ "nodetype" : "optional",
2470
+ "module" : "EtherLike-MIB",
2471
+ "description" :
2472
+ """This group is mandatory for all
2473
+ ethernet-like network interfaces which are
2474
+ capable of operating at 100 Mb/s or faster.""",
2475
+ },
2476
+ "etherStatsHalfDuplexGroup" : {
2477
+ "nodetype" : "optional",
2478
+ "module" : "EtherLike-MIB",
2479
+ "description" :
2480
+ """This group is mandatory for all
2481
+ ethernet-like network interfaces which are
2482
+
2483
+
2484
+
2485
+ capable of operating in half-duplex mode.""",
2486
+ },
2487
+ "etherHCStatsGroup" : {
2488
+ "nodetype" : "optional",
2489
+ "module" : "EtherLike-MIB",
2490
+ "description" :
2491
+ """This group is mandatory for all
2492
+ ethernet-like network interfaces which are
2493
+ capable of operating at 10 Gb/s or faster.
2494
+ It is recommended for all ethernet-like
2495
+ network interfaces which are capable of
2496
+ operating at 1000 Mb/s or faster.""",
2497
+ },
2498
+ "etherControlGroup" : {
2499
+ "nodetype" : "optional",
2500
+ "module" : "EtherLike-MIB",
2501
+ "description" :
2502
+ """This group is mandatory for all
2503
+ ethernet-like network interfaces that
2504
+ support the MAC Control sublayer.""",
2505
+ },
2506
+ "etherHCControlGroup" : {
2507
+ "nodetype" : "optional",
2508
+ "module" : "EtherLike-MIB",
2509
+ "description" :
2510
+ """This group is mandatory for all
2511
+ ethernet-like network interfaces that
2512
+ support the MAC Control sublayer and are
2513
+ capable of operating at 10 Gb/s or faster.""",
2514
+ },
2515
+ "etherControlPauseGroup" : {
2516
+ "nodetype" : "optional",
2517
+ "module" : "EtherLike-MIB",
2518
+ "description" :
2519
+ """This group is mandatory for all
2520
+ ethernet-like network interfaces that
2521
+ support the MAC Control PAUSE function.""",
2522
+ },
2523
+ "etherHCControlPauseGroup" : {
2524
+ "nodetype" : "optional",
2525
+ "module" : "EtherLike-MIB",
2526
+ "description" :
2527
+ """This group is mandatory for all
2528
+ ethernet-like network interfaces that
2529
+ support the MAC Control PAUSE function and
2530
+ are capable of operating at 10 Gb/s or
2531
+ faster.""",
2532
+ },
2533
+ "etherCollisionTableGroup" : {
2534
+ "nodetype" : "optional",
2535
+ "module" : "EtherLike-MIB",
2536
+ "description" :
2537
+ """This group is optional. It is appropriate
2538
+ for all ethernet-like network interfaces
2539
+ which are capable of operating in
2540
+ half-duplex mode and have the necessary
2541
+ metering. Implementation in systems with
2542
+ such interfaces is highly recommended.""",
2543
+ },
2544
+ }, # requires
2545
+ }, # compliance
2546
+ }, # compliances
2547
+
2548
+ }