logstash-input-snmp 0.1.0.beta4 → 0.1.0.beta5

Sign up to get free protection for your applications and to get access to all the features.
Files changed (309) hide show
  1. checksums.yaml +4 -4
  2. data/CHANGELOG.md +5 -0
  3. data/lib/logstash/inputs/snmp.rb +75 -12
  4. data/lib/logstash/inputs/snmp/base_client.rb +162 -0
  5. data/lib/logstash/inputs/snmp/client.rb +11 -109
  6. data/lib/logstash/inputs/snmp/clientv3.rb +139 -0
  7. data/lib/logstash/inputs/snmp/mib.rb +22 -20
  8. data/lib/mibs/ietf/ACCOUNTING-CONTROL-MIB.dic +1316 -0
  9. data/lib/mibs/ietf/ADSL-LINE-EXT-MIB.dic +1724 -0
  10. data/lib/mibs/ietf/ADSL-LINE-MIB.dic +7297 -0
  11. data/lib/mibs/ietf/ADSL-TC-MIB.dic +160 -0
  12. data/lib/mibs/ietf/ADSL2-LINE-MIB.dic +8663 -0
  13. data/lib/mibs/ietf/ADSL2-LINE-TC-MIB.dic +1462 -0
  14. data/lib/mibs/ietf/AGENTX-MIB.dic +817 -0
  15. data/lib/mibs/ietf/AGGREGATE-MIB.dic +708 -0
  16. data/lib/mibs/ietf/ALARM-MIB.dic +1734 -0
  17. data/lib/mibs/ietf/APM-MIB.dic +2870 -0
  18. data/lib/mibs/ietf/APPC-MIB.dic +8687 -0
  19. data/lib/mibs/ietf/APPLETALK-MIB.dic +4399 -0
  20. data/lib/mibs/ietf/APPLICATION-MIB.dic +3750 -0
  21. data/lib/mibs/ietf/APPN-DLUR-MIB.dic +972 -0
  22. data/lib/mibs/ietf/APPN-MIB.dic +9364 -0
  23. data/lib/mibs/ietf/APPN-TRAP-MIB.dic +664 -0
  24. data/lib/mibs/ietf/APS-MIB.dic +2430 -0
  25. data/lib/mibs/ietf/ARC-MIB.dic +552 -0
  26. data/lib/mibs/ietf/ATM-ACCOUNTING-INFORMATION-MIB.dic +816 -0
  27. data/lib/mibs/ietf/ATM-MIB.dic +4104 -0
  28. data/lib/mibs/ietf/ATM-TC-MIB.dic +914 -0
  29. data/lib/mibs/ietf/ATM2-MIB.dic +4715 -0
  30. data/lib/mibs/ietf/BFD-STD-MIB.dic +2367 -0
  31. data/lib/mibs/ietf/BFD-TC-STD-MIB.dic +202 -0
  32. data/lib/mibs/ietf/BGP4-MIB.dic +1931 -0
  33. data/lib/mibs/ietf/BLDG-HVAC-MIB.dic +812 -0
  34. data/lib/mibs/ietf/BRIDGE-MIB.dic +2257 -0
  35. data/lib/mibs/ietf/CAPWAP-BASE-MIB.dic +4128 -0
  36. data/lib/mibs/ietf/CAPWAP-DOT11-MIB.dic +482 -0
  37. data/lib/mibs/ietf/CHARACTER-MIB.dic +1140 -0
  38. data/lib/mibs/ietf/CIRCUIT-IF-MIB.dic +493 -0
  39. data/lib/mibs/ietf/CLNS-MIB.dic +1702 -0
  40. data/lib/mibs/ietf/COFFEE-POT-MIB.dic +282 -0
  41. data/lib/mibs/ietf/COPS-CLIENT-MIB.dic +1270 -0
  42. data/lib/mibs/ietf/DECNET-PHIV-MIB.dic +5837 -0
  43. data/lib/mibs/ietf/DIAL-CONTROL-MIB.dic +2139 -0
  44. data/lib/mibs/ietf/DIFFSERV-CONFIG-MIB.dic +378 -0
  45. data/lib/mibs/ietf/DIFFSERV-MIB.dic +5073 -0
  46. data/lib/mibs/ietf/DIRECTORY-SERVER-MIB.dic +1041 -0
  47. data/lib/mibs/ietf/DISMAN-EVENT-MIB.dic +3151 -0
  48. data/lib/mibs/ietf/DISMAN-EXPRESSION-MIB.dic +1716 -0
  49. data/lib/mibs/ietf/DISMAN-NSLOOKUP-MIB.dic +698 -0
  50. data/lib/mibs/ietf/DISMAN-PING-MIB.dic +2635 -0
  51. data/lib/mibs/ietf/DISMAN-SCHEDULE-MIB.dic +1744 -0
  52. data/lib/mibs/ietf/DISMAN-SCRIPT-MIB.dic +2820 -0
  53. data/lib/mibs/ietf/DISMAN-TRACEROUTE-MIB.dic +3239 -0
  54. data/lib/mibs/ietf/DLSW-MIB.dic +5635 -0
  55. data/lib/mibs/ietf/DNS-RESOLVER-MIB.dic +1765 -0
  56. data/lib/mibs/ietf/DNS-SERVER-MIB.dic +1593 -0
  57. data/lib/mibs/ietf/DOCS-BPI-MIB.dic +2634 -0
  58. data/lib/mibs/ietf/DOCS-CABLE-DEVICE-MIB.dic +5042 -0
  59. data/lib/mibs/ietf/DOCS-IETF-BPI2-MIB.dic +5478 -0
  60. data/lib/mibs/ietf/DOCS-IETF-CABLE-DEVICE-NOTIFICATION-MIB.dic +2447 -0
  61. data/lib/mibs/ietf/DOCS-IETF-QOS-MIB.dic +4886 -0
  62. data/lib/mibs/ietf/DOCS-IETF-SUBMGT-MIB.dic +1331 -0
  63. data/lib/mibs/ietf/DOCS-IF-MIB.dic +7980 -0
  64. data/lib/mibs/ietf/DOT12-IF-MIB.dic +1066 -0
  65. data/lib/mibs/ietf/DOT12-RPTR-MIB.dic +2669 -0
  66. data/lib/mibs/ietf/DOT3-EPON-MIB.dic +3297 -0
  67. data/lib/mibs/ietf/DOT3-OAM-MIB.dic +2830 -0
  68. data/lib/mibs/ietf/DS0-MIB.dic +466 -0
  69. data/lib/mibs/ietf/DS0BUNDLE-MIB.dic +468 -0
  70. data/lib/mibs/ietf/DS1-MIB.dic +4890 -0
  71. data/lib/mibs/ietf/DS3-MIB.dic +2719 -0
  72. data/lib/mibs/ietf/DSA-MIB.dic +888 -0
  73. data/lib/mibs/ietf/DSMON-MIB.dic +6177 -0
  74. data/lib/mibs/ietf/DVB-RCS-MIB.dic +5764 -0
  75. data/lib/mibs/ietf/EBN-MIB.dic +1026 -0
  76. data/lib/mibs/ietf/EFM-CU-MIB.dic +4335 -0
  77. data/lib/mibs/ietf/ENTITY-MIB.dic +2235 -0
  78. data/lib/mibs/ietf/ENTITY-SENSOR-MIB.dic +653 -0
  79. data/lib/mibs/ietf/ENTITY-STATE-MIB.dic +457 -0
  80. data/lib/mibs/ietf/ENTITY-STATE-TC-MIB.dic +260 -0
  81. data/lib/mibs/ietf/ETHER-CHIPSET-MIB.dic +787 -0
  82. data/lib/mibs/ietf/EtherLike-MIB.dic +2548 -0
  83. data/lib/mibs/ietf/FC-MGMT-MIB.dic +3465 -0
  84. data/lib/mibs/ietf/FCIP-MGMT-MIB.dic +1596 -0
  85. data/lib/mibs/ietf/FDDI-SMT73-MIB.dic +3378 -0
  86. data/lib/mibs/ietf/FIBRE-CHANNEL-FE-MIB.dic +2504 -0
  87. data/lib/mibs/ietf/FLOAT-TC-MIB.dic +128 -0
  88. data/lib/mibs/ietf/FLOW-METER-MIB.dic +3201 -0
  89. data/lib/mibs/ietf/FORCES-MIB.dic +598 -0
  90. data/lib/mibs/ietf/FR-ATM-PVC-SERVICE-IWF-MIB.dic +1601 -0
  91. data/lib/mibs/ietf/FR-MFR-MIB.dic +1351 -0
  92. data/lib/mibs/ietf/FRAME-RELAY-DTE-MIB.dic +1688 -0
  93. data/lib/mibs/ietf/FRNETSERV-MIB.dic +3940 -0
  94. data/lib/mibs/ietf/FRSLD-MIB.dic +2580 -0
  95. data/lib/mibs/ietf/Finisher-MIB.dic +1416 -0
  96. data/lib/mibs/ietf/GMPLS-LABEL-STD-MIB.dic +965 -0
  97. data/lib/mibs/ietf/GMPLS-LSR-STD-MIB.dic +693 -0
  98. data/lib/mibs/ietf/GMPLS-TC-STD-MIB.dic +180 -0
  99. data/lib/mibs/ietf/GMPLS-TE-STD-MIB.dic +2542 -0
  100. data/lib/mibs/ietf/GSMP-MIB.dic +2468 -0
  101. data/lib/mibs/ietf/HC-ALARM-MIB.dic +1050 -0
  102. data/lib/mibs/ietf/HC-PerfHist-TC-MIB.dic +310 -0
  103. data/lib/mibs/ietf/HC-RMON-MIB.dic +4456 -0
  104. data/lib/mibs/ietf/HDSL2-SHDSL-LINE-MIB.dic +3955 -0
  105. data/lib/mibs/ietf/HOST-RESOURCES-MIB.dic +2453 -0
  106. data/lib/mibs/ietf/HPR-IP-MIB.dic +640 -0
  107. data/lib/mibs/ietf/HPR-MIB.dic +1959 -0
  108. data/lib/mibs/ietf/IANA-ITU-ALARM-TC-MIB.dic +936 -0
  109. data/lib/mibs/ietf/IF-CAP-STACK-MIB.dic +356 -0
  110. data/lib/mibs/ietf/IF-INVERTED-STACK-MIB.dic +220 -0
  111. data/lib/mibs/ietf/IF-MIB.dic +2753 -0
  112. data/lib/mibs/ietf/IFCP-MGMT-MIB.dic +1717 -0
  113. data/lib/mibs/ietf/IGMP-STD-MIB.dic +809 -0
  114. data/lib/mibs/ietf/INET-ADDRESS-MIB.dic +570 -0
  115. data/lib/mibs/ietf/INTEGRATED-SERVICES-GUARANTEED-MIB.dic +319 -0
  116. data/lib/mibs/ietf/INTEGRATED-SERVICES-MIB.dic +1196 -0
  117. data/lib/mibs/ietf/INTERFACETOPN-MIB.dic +1705 -0
  118. data/lib/mibs/ietf/IP-FORWARD-MIB.dic +1853 -0
  119. data/lib/mibs/ietf/IP-MIB.dic +7064 -0
  120. data/lib/mibs/ietf/IPATM-IPMC-MIB.dic +4830 -0
  121. data/lib/mibs/ietf/IPFIX-MIB.dic +2334 -0
  122. data/lib/mibs/ietf/IPFIX-SELECTOR-MIB.dic +215 -0
  123. data/lib/mibs/ietf/IPMCAST-MIB.dic +3390 -0
  124. data/lib/mibs/ietf/IPMROUTE-STD-MIB.dic +1246 -0
  125. data/lib/mibs/ietf/IPOA-MIB.dic +2372 -0
  126. data/lib/mibs/ietf/IPS-AUTH-MIB.dic +1609 -0
  127. data/lib/mibs/ietf/IPSEC-SPD-MIB.dic +3989 -0
  128. data/lib/mibs/ietf/IPV6-FLOW-LABEL-MIB.dic +110 -0
  129. data/lib/mibs/ietf/IPV6-ICMP-MIB.dic +748 -0
  130. data/lib/mibs/ietf/IPV6-MIB.dic +2028 -0
  131. data/lib/mibs/ietf/IPV6-MLD-MIB.dic +659 -0
  132. data/lib/mibs/ietf/IPV6-TCP-MIB.dic +332 -0
  133. data/lib/mibs/ietf/IPV6-UDP-MIB.dic +209 -0
  134. data/lib/mibs/ietf/ISCSI-MIB.dic +4613 -0
  135. data/lib/mibs/ietf/ISDN-MIB.dic +1796 -0
  136. data/lib/mibs/ietf/ISIS-MIB.dic +6215 -0
  137. data/lib/mibs/ietf/ISNS-MIB.dic +6578 -0
  138. data/lib/mibs/ietf/ITU-ALARM-MIB.dic +665 -0
  139. data/lib/mibs/ietf/ITU-ALARM-TC-MIB.dic +137 -0
  140. data/lib/mibs/ietf/Job-Monitoring-MIB.dic +2519 -0
  141. data/lib/mibs/ietf/L2TP-MIB.dic +4050 -0
  142. data/lib/mibs/ietf/LANGTAG-TC-MIB.dic +104 -0
  143. data/lib/mibs/ietf/LISP-MIB.dic +4067 -0
  144. data/lib/mibs/ietf/LMP-MIB.dic +5166 -0
  145. data/lib/mibs/ietf/MALLOC-MIB.dic +2156 -0
  146. data/lib/mibs/ietf/MAU-MIB.dic +2619 -0
  147. data/lib/mibs/ietf/MIDCOM-MIB.dic +2856 -0
  148. data/lib/mibs/ietf/MIOX25-MIB.dic +828 -0
  149. data/lib/mibs/ietf/MIP-MIB.dic +3473 -0
  150. data/lib/mibs/ietf/MOBILEIPV6-MIB.dic +5228 -0
  151. data/lib/mibs/ietf/MPLS-FTN-STD-MIB.dic +1594 -0
  152. data/lib/mibs/ietf/MPLS-L3VPN-STD-MIB.dic +2548 -0
  153. data/lib/mibs/ietf/MPLS-LC-ATM-STD-MIB.dic +491 -0
  154. data/lib/mibs/ietf/MPLS-LC-FR-STD-MIB.dic +395 -0
  155. data/lib/mibs/ietf/MPLS-LDP-ATM-STD-MIB.dic +1019 -0
  156. data/lib/mibs/ietf/MPLS-LDP-FRAME-RELAY-STD-MIB.dic +862 -0
  157. data/lib/mibs/ietf/MPLS-LDP-GENERIC-STD-MIB.dic +445 -0
  158. data/lib/mibs/ietf/MPLS-LDP-STD-MIB.dic +3657 -0
  159. data/lib/mibs/ietf/MPLS-LSR-STD-MIB.dic +3103 -0
  160. data/lib/mibs/ietf/MPLS-TC-STD-MIB.dic +911 -0
  161. data/lib/mibs/ietf/MPLS-TE-STD-MIB.dic +3673 -0
  162. data/lib/mibs/ietf/MSDP-MIB.dic +1893 -0
  163. data/lib/mibs/ietf/MTA-MIB.dic +1898 -0
  164. data/lib/mibs/ietf/Modem-MIB.dic +2054 -0
  165. data/lib/mibs/ietf/NAT-MIB.dic +3866 -0
  166. data/lib/mibs/ietf/NETWORK-SERVICES-MIB.dic +1034 -0
  167. data/lib/mibs/ietf/NHDP-MIB.dic +3005 -0
  168. data/lib/mibs/ietf/NHRP-MIB.dic +3660 -0
  169. data/lib/mibs/ietf/NOTIFICATION-LOG-MIB.dic +1156 -0
  170. data/lib/mibs/ietf/NTPv4-MIB.dic +1535 -0
  171. data/lib/mibs/ietf/OPT-IF-MIB.dic +8972 -0
  172. data/lib/mibs/ietf/OSPF-MIB.dic +5963 -0
  173. data/lib/mibs/ietf/OSPF-TRAP-MIB.dic +1190 -0
  174. data/lib/mibs/ietf/OSPFV3-MIB.dic +5708 -0
  175. data/lib/mibs/ietf/P-BRIDGE-MIB.dic +1499 -0
  176. data/lib/mibs/ietf/PARALLEL-MIB.dic +476 -0
  177. data/lib/mibs/ietf/PIM-MIB.dic +1393 -0
  178. data/lib/mibs/ietf/PIM-STD-MIB.dic +6819 -0
  179. data/lib/mibs/ietf/PINT-MIB.dic +830 -0
  180. data/lib/mibs/ietf/PKTC-IETF-MTA-MIB.dic +3191 -0
  181. data/lib/mibs/ietf/PKTC-IETF-SIG-MIB.dic +4713 -0
  182. data/lib/mibs/ietf/PMIPV6-MIB.dic +3010 -0
  183. data/lib/mibs/ietf/PMIPV6-TC-MIB.dic +293 -0
  184. data/lib/mibs/ietf/POLICY-BASED-MANAGEMENT-MIB.dic +3316 -0
  185. data/lib/mibs/ietf/POWER-ETHERNET-MIB.dic +959 -0
  186. data/lib/mibs/ietf/PPP-BRIDGE-NCP-MIB.dic +587 -0
  187. data/lib/mibs/ietf/PPP-IP-NCP-MIB.dic +269 -0
  188. data/lib/mibs/ietf/PPP-LCP-MIB.dic +994 -0
  189. data/lib/mibs/ietf/PPP-SEC-MIB.dic +411 -0
  190. data/lib/mibs/ietf/PSAMP-MIB.dic +998 -0
  191. data/lib/mibs/ietf/PTOPO-MIB.dic +1135 -0
  192. data/lib/mibs/ietf/PW-ATM-MIB.dic +1642 -0
  193. data/lib/mibs/ietf/PW-CEP-STD-MIB.dic +3661 -0
  194. data/lib/mibs/ietf/PW-STD-MIB.dic +3592 -0
  195. data/lib/mibs/ietf/PW-TC-STD-MIB.dic +437 -0
  196. data/lib/mibs/ietf/PW-TDM-MIB.dic +1896 -0
  197. data/lib/mibs/ietf/PerfHist-TC-MIB.dic +152 -0
  198. data/lib/mibs/ietf/Printer-MIB.dic +6665 -0
  199. data/lib/mibs/ietf/Q-BRIDGE-MIB.dic +3115 -0
  200. data/lib/mibs/ietf/RADIUS-ACC-CLIENT-MIB.dic +991 -0
  201. data/lib/mibs/ietf/RADIUS-ACC-SERVER-MIB.dic +1183 -0
  202. data/lib/mibs/ietf/RADIUS-AUTH-CLIENT-MIB.dic +1073 -0
  203. data/lib/mibs/ietf/RADIUS-AUTH-SERVER-MIB.dic +1251 -0
  204. data/lib/mibs/ietf/RADIUS-DYNAUTH-CLIENT-MIB.dic +1116 -0
  205. data/lib/mibs/ietf/RADIUS-DYNAUTH-SERVER-MIB.dic +1003 -0
  206. data/lib/mibs/ietf/RAQMON-MIB.dic +2695 -0
  207. data/lib/mibs/ietf/RBRIDGE-MIB.dic +2981 -0
  208. data/lib/mibs/ietf/RDBMS-MIB.dic +1935 -0
  209. data/lib/mibs/ietf/RFC1065-SMI.dic +108 -0
  210. data/lib/mibs/ietf/RFC1155-SMI.dic +118 -0
  211. data/lib/mibs/ietf/RFC1158-MIB.dic +2440 -0
  212. data/lib/mibs/ietf/RFC1213-MIB.dic +3434 -0
  213. data/lib/mibs/ietf/RFC1269-MIB.dic +557 -0
  214. data/lib/mibs/ietf/RFC1271-MIB.dic +4135 -0
  215. data/lib/mibs/ietf/RFC1285-MIB.dic +2842 -0
  216. data/lib/mibs/ietf/RFC1316-MIB.dic +800 -0
  217. data/lib/mibs/ietf/RFC1381-MIB.dic +1347 -0
  218. data/lib/mibs/ietf/RFC1382-MIB.dic +3820 -0
  219. data/lib/mibs/ietf/RFC1414-MIB.dic +214 -0
  220. data/lib/mibs/ietf/RIPv2-MIB.dic +773 -0
  221. data/lib/mibs/ietf/RMON-MIB.dic +5551 -0
  222. data/lib/mibs/ietf/RMON2-MIB.dic +8224 -0
  223. data/lib/mibs/ietf/ROHC-MIB.dic +1613 -0
  224. data/lib/mibs/ietf/ROHC-RTP-MIB.dic +859 -0
  225. data/lib/mibs/ietf/ROHC-UNCOMPRESSED-MIB.dic +267 -0
  226. data/lib/mibs/ietf/RPKI-ROUTER-MIB.dic +1363 -0
  227. data/lib/mibs/ietf/RS-232-MIB.dic +1335 -0
  228. data/lib/mibs/ietf/RSERPOOL-MIB.dic +2501 -0
  229. data/lib/mibs/ietf/RSTP-MIB.dic +427 -0
  230. data/lib/mibs/ietf/RSVP-MIB.dic +4135 -0
  231. data/lib/mibs/ietf/RTP-MIB.dic +1376 -0
  232. data/lib/mibs/ietf/SCSI-MIB.dic +3804 -0
  233. data/lib/mibs/ietf/SCTP-MIB.dic +1924 -0
  234. data/lib/mibs/ietf/SFLOW-MIB.dic +568 -0
  235. data/lib/mibs/ietf/SIP-COMMON-MIB.dic +2769 -0
  236. data/lib/mibs/ietf/SIP-MIB.dic +1438 -0
  237. data/lib/mibs/ietf/SIP-SERVER-MIB.dic +1150 -0
  238. data/lib/mibs/ietf/SIP-TC-MIB.dic +257 -0
  239. data/lib/mibs/ietf/SIP-UA-MIB.dic +268 -0
  240. data/lib/mibs/ietf/SLAPM-MIB.dic +4527 -0
  241. data/lib/mibs/ietf/SMON-MIB.dic +1758 -0
  242. data/lib/mibs/ietf/SNA-NAU-MIB.dic +4042 -0
  243. data/lib/mibs/ietf/SNA-SDLC-MIB.dic +3858 -0
  244. data/lib/mibs/ietf/SNMP-COMMUNITY-MIB.dic +715 -0
  245. data/lib/mibs/ietf/SNMP-FRAMEWORK-MIB.dic +709 -0
  246. data/lib/mibs/ietf/SNMP-MPD-MIB.dic +230 -0
  247. data/lib/mibs/ietf/SNMP-NOTIFICATION-MIB.dic +859 -0
  248. data/lib/mibs/ietf/SNMP-PROXY-MIB.dic +414 -0
  249. data/lib/mibs/ietf/SNMP-REPEATER-MIB.dic +4335 -0
  250. data/lib/mibs/ietf/SNMP-SSH-TM-MIB.dic +447 -0
  251. data/lib/mibs/ietf/SNMP-TARGET-MIB.dic +924 -0
  252. data/lib/mibs/ietf/SNMP-TLS-TM-MIB.dic +1449 -0
  253. data/lib/mibs/ietf/SNMP-TSM-MIB.dic +315 -0
  254. data/lib/mibs/ietf/SNMP-USER-BASED-SM-MIB.dic +1164 -0
  255. data/lib/mibs/ietf/SNMP-USM-AES-MIB.dic +95 -0
  256. data/lib/mibs/ietf/SNMP-USM-DH-OBJECTS-MIB.dic +653 -0
  257. data/lib/mibs/ietf/SNMP-VIEW-BASED-ACM-MIB.dic +1202 -0
  258. data/lib/mibs/ietf/SNMPv2-MIB.dic +1382 -0
  259. data/lib/mibs/ietf/SNMPv2-SMI.dic +223 -0
  260. data/lib/mibs/ietf/SNMPv2-USEC-MIB.dic +405 -0
  261. data/lib/mibs/ietf/SONET-MIB.dic +3308 -0
  262. data/lib/mibs/ietf/SOURCE-ROUTING-MIB.dic +542 -0
  263. data/lib/mibs/ietf/SSPM-MIB.dic +1530 -0
  264. data/lib/mibs/ietf/SYSAPPL-MIB.dic +2092 -0
  265. data/lib/mibs/ietf/T11-FC-FABRIC-ADDR-MGR-MIB.dic +1779 -0
  266. data/lib/mibs/ietf/T11-FC-FABRIC-CONFIG-SERVER-MIB.dic +2822 -0
  267. data/lib/mibs/ietf/T11-FC-FABRIC-LOCK-MIB.dic +700 -0
  268. data/lib/mibs/ietf/T11-FC-FSPF-MIB.dic +1889 -0
  269. data/lib/mibs/ietf/T11-FC-NAME-SERVER-MIB.dic +1775 -0
  270. data/lib/mibs/ietf/T11-FC-ROUTE-MIB.dic +655 -0
  271. data/lib/mibs/ietf/T11-FC-RSCN-MIB.dic +1110 -0
  272. data/lib/mibs/ietf/T11-FC-VIRTUAL-FABRIC-MIB.dic +770 -0
  273. data/lib/mibs/ietf/T11-FC-ZONE-SERVER-MIB.dic +3886 -0
  274. data/lib/mibs/ietf/T11-TC-MIB.dic +110 -0
  275. data/lib/mibs/ietf/TCP-ESTATS-MIB.dic +3926 -0
  276. data/lib/mibs/ietf/TCP-MIB.dic +1319 -0
  277. data/lib/mibs/ietf/TCPIPX-MIB.dic +457 -0
  278. data/lib/mibs/ietf/TE-LINK-STD-MIB.dic +2876 -0
  279. data/lib/mibs/ietf/TE-MIB.dic +2924 -0
  280. data/lib/mibs/ietf/TED-MIB.dic +1749 -0
  281. data/lib/mibs/ietf/TIME-AGGREGATE-MIB.dic +550 -0
  282. data/lib/mibs/ietf/TN3270E-MIB.dic +2785 -0
  283. data/lib/mibs/ietf/TN3270E-RT-MIB.dic +1317 -0
  284. data/lib/mibs/ietf/TOKEN-RING-RMON-MIB.dic +2820 -0
  285. data/lib/mibs/ietf/TOKENRING-MIB.dic +1184 -0
  286. data/lib/mibs/ietf/TOKENRING-STATION-SR-MIB.dic +292 -0
  287. data/lib/mibs/ietf/TRANSPORT-ADDRESS-MIB.dic +610 -0
  288. data/lib/mibs/ietf/TRIP-MIB.dic +3159 -0
  289. data/lib/mibs/ietf/TRIP-TC-MIB.dic +241 -0
  290. data/lib/mibs/ietf/TUNNEL-MIB.dic +1095 -0
  291. data/lib/mibs/ietf/UDP-MIB.dic +751 -0
  292. data/lib/mibs/ietf/UDPLITE-MIB.dic +704 -0
  293. data/lib/mibs/ietf/UPS-MIB.dic +3088 -0
  294. data/lib/mibs/ietf/URI-TC-MIB.dic +193 -0
  295. data/lib/mibs/ietf/UUID-TC-MIB.dic +135 -0
  296. data/lib/mibs/ietf/VDSL-LINE-EXT-MCM-MIB.dic +989 -0
  297. data/lib/mibs/ietf/VDSL-LINE-EXT-SCM-MIB.dic +605 -0
  298. data/lib/mibs/ietf/VDSL-LINE-MIB.dic +4518 -0
  299. data/lib/mibs/ietf/VDSL2-LINE-MIB.dic +11029 -0
  300. data/lib/mibs/ietf/VDSL2-LINE-TC-MIB.dic +3152 -0
  301. data/lib/mibs/ietf/VPN-TC-STD-MIB.dic +121 -0
  302. data/lib/mibs/ietf/VRRP-MIB.dic +1163 -0
  303. data/lib/mibs/ietf/VRRPV3-MIB.dic +1403 -0
  304. data/lib/mibs/ietf/WWW-MIB.dic +1810 -0
  305. data/lib/mibs/logstash/iso.dic +18 -0
  306. data/logstash-input-snmp.gemspec +1 -1
  307. data/spec/inputs/snmp/mib_spec.rb +10 -17
  308. data/spec/inputs/snmp_spec.rb +27 -1
  309. metadata +302 -2
@@ -0,0 +1,414 @@
1
+ # python version 1.0 DO NOT EDIT
2
+ #
3
+ # This python file has been generated by smidump version 0.5.0:
4
+ #
5
+ # smidump -f python SNMP-PROXY-MIB
6
+
7
+ FILENAME = "./libsmi-0.5.0/mibs/ietf/SNMP-PROXY-MIB"
8
+
9
+ MIB = {
10
+ "moduleName" : "SNMP-PROXY-MIB",
11
+
12
+ "SNMP-PROXY-MIB" : {
13
+ "nodetype" : "module",
14
+ "language" : "SMIv2",
15
+ "organization" :
16
+ """IETF SNMPv3 Working Group""",
17
+ "contact" :
18
+ """WG-email: snmpv3@lists.tislabs.com
19
+ Subscribe: majordomo@lists.tislabs.com
20
+ In message body: subscribe snmpv3
21
+
22
+ Co-Chair: Russ Mundy
23
+ Network Associates Laboratories
24
+ Postal: 15204 Omega Drive, Suite 300
25
+ Rockville, MD 20850-4601
26
+ USA
27
+ EMail: mundy@tislabs.com
28
+ Phone: +1 301-947-7107
29
+
30
+
31
+ Co-Chair: David Harrington
32
+ Enterasys Networks
33
+ Postal: 35 Industrial Way
34
+ P. O. Box 5004
35
+ Rochester, New Hampshire 03866-5005
36
+ USA
37
+ EMail: dbh@enterasys.com
38
+ Phone: +1 603-337-2614
39
+
40
+ Co-editor: David B. Levi
41
+ Nortel Networks
42
+ Postal: 3505 Kesterwood Drive
43
+ Knoxville, Tennessee 37918
44
+ EMail: dlevi@nortelnetworks.com
45
+ Phone: +1 865 686 0432
46
+
47
+ Co-editor: Paul Meyer
48
+ Secure Computing Corporation
49
+ Postal: 2675 Long Lake Road
50
+ Roseville, Minnesota 55113
51
+ EMail: paul_meyer@securecomputing.com
52
+ Phone: +1 651 628 1592
53
+
54
+ Co-editor: Bob Stewart
55
+ Retired""",
56
+ "description" :
57
+ """This MIB module defines MIB objects which provide
58
+ mechanisms to remotely configure the parameters
59
+ used by a proxy forwarding application.
60
+
61
+ Copyright (C) The Internet Society (2002). This
62
+ version of this MIB module is part of RFC 3413;
63
+ see the RFC itself for full legal notices.""",
64
+ "revisions" : (
65
+ {
66
+ "date" : "2002-10-14 00:00",
67
+ "description" :
68
+ """Clarifications, published as
69
+ RFC 3413.""",
70
+ },
71
+ {
72
+ "date" : "1998-08-04 00:00",
73
+ "description" :
74
+ """Clarifications, published as
75
+ RFC 2573.""",
76
+ },
77
+ {
78
+ "date" : "1997-07-14 00:00",
79
+ "description" :
80
+ """The initial revision, published as RFC2273.""",
81
+ },
82
+ ),
83
+ "identity node" : "snmpProxyMIB",
84
+ },
85
+
86
+ "imports" : (
87
+ {"module" : "SNMPv2-SMI", "name" : "MODULE-IDENTITY"},
88
+ {"module" : "SNMPv2-SMI", "name" : "OBJECT-TYPE"},
89
+ {"module" : "SNMPv2-SMI", "name" : "snmpModules"},
90
+ {"module" : "SNMPv2-TC", "name" : "RowStatus"},
91
+ {"module" : "SNMPv2-TC", "name" : "StorageType"},
92
+ {"module" : "SNMP-FRAMEWORK-MIB", "name" : "SnmpEngineID"},
93
+ {"module" : "SNMP-FRAMEWORK-MIB", "name" : "SnmpAdminString"},
94
+ {"module" : "SNMP-TARGET-MIB", "name" : "SnmpTagValue"},
95
+ {"module" : "SNMPv2-CONF", "name" : "MODULE-COMPLIANCE"},
96
+ {"module" : "SNMPv2-CONF", "name" : "OBJECT-GROUP"},
97
+ {"module" : "SNMP-TARGET-MIB", "name" : "snmpTargetBasicGroup"},
98
+ {"module" : "SNMP-TARGET-MIB", "name" : "snmpTargetResponseGroup"},
99
+ ),
100
+
101
+ "nodes" : {
102
+ "snmpProxyMIB" : {
103
+ "nodetype" : "node",
104
+ "moduleName" : "SNMP-PROXY-MIB",
105
+ "oid" : "1.3.6.1.6.3.14",
106
+ "status" : "current",
107
+ }, # node
108
+ "snmpProxyObjects" : {
109
+ "nodetype" : "node",
110
+ "moduleName" : "SNMP-PROXY-MIB",
111
+ "oid" : "1.3.6.1.6.3.14.1",
112
+ }, # node
113
+ "snmpProxyTable" : {
114
+ "nodetype" : "table",
115
+ "moduleName" : "SNMP-PROXY-MIB",
116
+ "oid" : "1.3.6.1.6.3.14.1.2",
117
+ "status" : "current",
118
+ "description" :
119
+ """The table of translation parameters used by proxy forwarder
120
+ applications for forwarding SNMP messages.""",
121
+ }, # table
122
+ "snmpProxyEntry" : {
123
+ "nodetype" : "row",
124
+ "moduleName" : "SNMP-PROXY-MIB",
125
+ "oid" : "1.3.6.1.6.3.14.1.2.1",
126
+ "create" : "true",
127
+ "status" : "current",
128
+ "implied" : "true",
129
+ "linkage" : [
130
+ "snmpProxyName",
131
+ ],
132
+ "description" :
133
+ """A set of translation parameters used by a proxy forwarder
134
+ application for forwarding SNMP messages.
135
+
136
+ Entries in the snmpProxyTable are created and deleted
137
+ using the snmpProxyRowStatus object.""",
138
+ }, # row
139
+ "snmpProxyName" : {
140
+ "nodetype" : "column",
141
+ "moduleName" : "SNMP-PROXY-MIB",
142
+ "oid" : "1.3.6.1.6.3.14.1.2.1.1",
143
+ "status" : "current",
144
+ "syntax" : {
145
+ "type" : {
146
+ "basetype" : "OctetString",
147
+ "parent module" : {
148
+ "name" : "SNMP-FRAMEWORK-MIB",
149
+ "type" : "SnmpAdminString",
150
+ },
151
+ "ranges" : [
152
+ {
153
+ "min" : "1",
154
+ "max" : "32"
155
+ },
156
+ ],
157
+ "range" : {
158
+ "min" : "1",
159
+ "max" : "32"
160
+ },
161
+ },
162
+ },
163
+ "access" : "noaccess",
164
+ "description" :
165
+ """The locally arbitrary, but unique identifier associated
166
+ with this snmpProxyEntry.""",
167
+ }, # column
168
+ "snmpProxyType" : {
169
+ "nodetype" : "column",
170
+ "moduleName" : "SNMP-PROXY-MIB",
171
+ "oid" : "1.3.6.1.6.3.14.1.2.1.2",
172
+ "status" : "current",
173
+ "syntax" : {
174
+ "type" : {
175
+ "basetype" : "Enumeration",
176
+ "read" : {
177
+ "nodetype" : "namednumber",
178
+ "number" : "1"
179
+ },
180
+ "write" : {
181
+ "nodetype" : "namednumber",
182
+ "number" : "2"
183
+ },
184
+ "trap" : {
185
+ "nodetype" : "namednumber",
186
+ "number" : "3"
187
+ },
188
+ "inform" : {
189
+ "nodetype" : "namednumber",
190
+ "number" : "4"
191
+ },
192
+ },
193
+ },
194
+ "access" : "readwrite",
195
+ "description" :
196
+ """The type of message that may be forwarded using
197
+ the translation parameters defined by this entry.""",
198
+ }, # column
199
+ "snmpProxyContextEngineID" : {
200
+ "nodetype" : "column",
201
+ "moduleName" : "SNMP-PROXY-MIB",
202
+ "oid" : "1.3.6.1.6.3.14.1.2.1.3",
203
+ "status" : "current",
204
+ "syntax" : {
205
+ "type" : { "module" :"SNMP-FRAMEWORK-MIB", "name" : "SnmpEngineID"},
206
+ },
207
+ "access" : "readwrite",
208
+ "description" :
209
+ """The contextEngineID contained in messages that
210
+ may be forwarded using the translation parameters
211
+ defined by this entry.""",
212
+ }, # column
213
+ "snmpProxyContextName" : {
214
+ "nodetype" : "column",
215
+ "moduleName" : "SNMP-PROXY-MIB",
216
+ "oid" : "1.3.6.1.6.3.14.1.2.1.4",
217
+ "status" : "current",
218
+ "syntax" : {
219
+ "type" : { "module" :"SNMP-FRAMEWORK-MIB", "name" : "SnmpAdminString"},
220
+ },
221
+ "access" : "readwrite",
222
+ "description" :
223
+ """The contextName contained in messages that may be
224
+ forwarded using the translation parameters defined
225
+ by this entry.
226
+
227
+ This object is optional, and if not supported, the
228
+ contextName contained in a message is ignored when
229
+ selecting an entry in the snmpProxyTable.""",
230
+ }, # column
231
+ "snmpProxyTargetParamsIn" : {
232
+ "nodetype" : "column",
233
+ "moduleName" : "SNMP-PROXY-MIB",
234
+ "oid" : "1.3.6.1.6.3.14.1.2.1.5",
235
+ "status" : "current",
236
+ "syntax" : {
237
+ "type" : { "module" :"SNMP-FRAMEWORK-MIB", "name" : "SnmpAdminString"},
238
+ },
239
+ "access" : "readwrite",
240
+ "description" :
241
+ """This object selects an entry in the snmpTargetParamsTable.
242
+ The selected entry is used to determine which row of the
243
+ snmpProxyTable to use for forwarding received messages.""",
244
+ }, # column
245
+ "snmpProxySingleTargetOut" : {
246
+ "nodetype" : "column",
247
+ "moduleName" : "SNMP-PROXY-MIB",
248
+ "oid" : "1.3.6.1.6.3.14.1.2.1.6",
249
+ "status" : "current",
250
+ "syntax" : {
251
+ "type" : { "module" :"SNMP-FRAMEWORK-MIB", "name" : "SnmpAdminString"},
252
+ },
253
+ "access" : "readwrite",
254
+ "description" :
255
+ """This object selects a management target defined in the
256
+ snmpTargetAddrTable (in the SNMP-TARGET-MIB). The
257
+ selected target is defined by an entry in the
258
+ snmpTargetAddrTable whose index value (snmpTargetAddrName)
259
+ is equal to this object.
260
+
261
+ This object is only used when selection of a single
262
+ target is required (i.e. when forwarding an incoming
263
+ read or write request).""",
264
+ }, # column
265
+ "snmpProxyMultipleTargetOut" : {
266
+ "nodetype" : "column",
267
+ "moduleName" : "SNMP-PROXY-MIB",
268
+ "oid" : "1.3.6.1.6.3.14.1.2.1.7",
269
+ "status" : "current",
270
+ "syntax" : {
271
+ "type" : { "module" :"SNMP-TARGET-MIB", "name" : "SnmpTagValue"},
272
+ },
273
+ "access" : "readwrite",
274
+ "description" :
275
+ """This object selects a set of management targets defined
276
+ in the snmpTargetAddrTable (in the SNMP-TARGET-MIB).
277
+
278
+ This object is only used when selection of multiple
279
+ targets is required (i.e. when forwarding an incoming
280
+ notification).""",
281
+ }, # column
282
+ "snmpProxyStorageType" : {
283
+ "nodetype" : "column",
284
+ "moduleName" : "SNMP-PROXY-MIB",
285
+ "oid" : "1.3.6.1.6.3.14.1.2.1.8",
286
+ "status" : "current",
287
+ "syntax" : {
288
+ "type" : { "module" :"SNMPv2-TC", "name" : "StorageType"},
289
+ },
290
+ "access" : "readwrite",
291
+ "default" : "nonVolatile",
292
+ "description" :
293
+ """The storage type of this conceptual row.
294
+ Conceptual rows having the value 'permanent' need not
295
+ allow write-access to any columnar objects in the row.""",
296
+ }, # column
297
+ "snmpProxyRowStatus" : {
298
+ "nodetype" : "column",
299
+ "moduleName" : "SNMP-PROXY-MIB",
300
+ "oid" : "1.3.6.1.6.3.14.1.2.1.9",
301
+ "status" : "current",
302
+ "syntax" : {
303
+ "type" : { "module" :"SNMPv2-TC", "name" : "RowStatus"},
304
+ },
305
+ "access" : "readwrite",
306
+ "description" :
307
+ """The status of this conceptual row.
308
+
309
+ To create a row in this table, a manager must
310
+
311
+
312
+ set this object to either createAndGo(4) or
313
+ createAndWait(5).
314
+
315
+ The following objects may not be modified while the
316
+ value of this object is active(1):
317
+ - snmpProxyType
318
+ - snmpProxyContextEngineID
319
+ - snmpProxyContextName
320
+ - snmpProxyTargetParamsIn
321
+ - snmpProxySingleTargetOut
322
+ - snmpProxyMultipleTargetOut""",
323
+ }, # column
324
+ "snmpProxyConformance" : {
325
+ "nodetype" : "node",
326
+ "moduleName" : "SNMP-PROXY-MIB",
327
+ "oid" : "1.3.6.1.6.3.14.3",
328
+ }, # node
329
+ "snmpProxyCompliances" : {
330
+ "nodetype" : "node",
331
+ "moduleName" : "SNMP-PROXY-MIB",
332
+ "oid" : "1.3.6.1.6.3.14.3.1",
333
+ }, # node
334
+ "snmpProxyGroups" : {
335
+ "nodetype" : "node",
336
+ "moduleName" : "SNMP-PROXY-MIB",
337
+ "oid" : "1.3.6.1.6.3.14.3.2",
338
+ }, # node
339
+ }, # nodes
340
+
341
+ "groups" : {
342
+ "snmpProxyGroup" : {
343
+ "nodetype" : "group",
344
+ "moduleName" : "SNMP-PROXY-MIB",
345
+ "oid" : "1.3.6.1.6.3.14.3.2.3",
346
+ "status" : "current",
347
+ "members" : {
348
+ "snmpProxyType" : {
349
+ "nodetype" : "member",
350
+ "module" : "SNMP-PROXY-MIB"
351
+ },
352
+ "snmpProxyContextEngineID" : {
353
+ "nodetype" : "member",
354
+ "module" : "SNMP-PROXY-MIB"
355
+ },
356
+ "snmpProxyContextName" : {
357
+ "nodetype" : "member",
358
+ "module" : "SNMP-PROXY-MIB"
359
+ },
360
+ "snmpProxyTargetParamsIn" : {
361
+ "nodetype" : "member",
362
+ "module" : "SNMP-PROXY-MIB"
363
+ },
364
+ "snmpProxySingleTargetOut" : {
365
+ "nodetype" : "member",
366
+ "module" : "SNMP-PROXY-MIB"
367
+ },
368
+ "snmpProxyMultipleTargetOut" : {
369
+ "nodetype" : "member",
370
+ "module" : "SNMP-PROXY-MIB"
371
+ },
372
+ "snmpProxyStorageType" : {
373
+ "nodetype" : "member",
374
+ "module" : "SNMP-PROXY-MIB"
375
+ },
376
+ "snmpProxyRowStatus" : {
377
+ "nodetype" : "member",
378
+ "module" : "SNMP-PROXY-MIB"
379
+ },
380
+ }, # members
381
+ "description" :
382
+ """A collection of objects providing remote configuration of
383
+ management target translation parameters for use by
384
+ proxy forwarder applications.""",
385
+ }, # group
386
+ }, # groups
387
+
388
+ "compliances" : {
389
+ "snmpProxyCompliance" : {
390
+ "nodetype" : "compliance",
391
+ "moduleName" : "SNMP-PROXY-MIB",
392
+ "oid" : "1.3.6.1.6.3.14.3.1.1",
393
+ "status" : "current",
394
+ "description" :
395
+ """The compliance statement for SNMP entities which include
396
+ a proxy forwarding application.""",
397
+ "requires" : {
398
+ "snmpTargetBasicGroup" : {
399
+ "nodetype" : "mandatory",
400
+ "module" : "SNMP-TARGET-MIB"
401
+ },
402
+ "snmpTargetResponseGroup" : {
403
+ "nodetype" : "mandatory",
404
+ "module" : "SNMP-TARGET-MIB"
405
+ },
406
+ "snmpProxyGroup" : {
407
+ "nodetype" : "mandatory",
408
+ "module" : "SNMP-PROXY-MIB"
409
+ },
410
+ }, # requires
411
+ }, # compliance
412
+ }, # compliances
413
+
414
+ }
@@ -0,0 +1,4335 @@
1
+ # python version 1.0 DO NOT EDIT
2
+ #
3
+ # This python file has been generated by smidump version 0.5.0:
4
+ #
5
+ # smidump -f python SNMP-REPEATER-MIB
6
+
7
+ FILENAME = "./libsmi-0.5.0/mibs/ietf/SNMP-REPEATER-MIB"
8
+
9
+ MIB = {
10
+ "moduleName" : "SNMP-REPEATER-MIB",
11
+
12
+ "SNMP-REPEATER-MIB" : {
13
+ "nodetype" : "module",
14
+ "language" : "SMIv2",
15
+ "organization" :
16
+ """IETF HUB MIB Working Group""",
17
+ "contact" :
18
+ """WG E-mail: hubmib@hprnd.rose.hp.com
19
+
20
+ Chair: Dan Romascanu
21
+ Postal: Madge Networks (Israel) Ltd.
22
+ Atidim Technology Park, Bldg. 3
23
+ Tel Aviv 61131, Israel
24
+ Tel: 972-3-6458414, 6458458
25
+ Fax: 972-3-6487146
26
+ E-mail: dromasca@madge.com
27
+
28
+ Editor: Kathryn de Graaf
29
+ Postal: 3Com Corporation
30
+ 118 Turnpike Rd.
31
+ Southborough, MA 01772 USA
32
+ Tel: (508)229-1627
33
+ Fax: (508)490-5882
34
+ E-mail: kdegraaf@isd.3com.com""",
35
+ "description" :
36
+ """Management information for 802.3 repeaters.
37
+
38
+ The following references are used throughout
39
+ this MIB module:
40
+
41
+ [IEEE 802.3 Std]
42
+ refers to IEEE 802.3/ISO 8802-3 Information
43
+ processing systems - Local area networks -
44
+ Part 3: Carrier sense multiple access with
45
+ collision detection (CSMA/CD) access method
46
+ and physical layer specifications (1993).
47
+
48
+ [IEEE 802.3 Mgt]
49
+ refers to IEEE 802.3u-1995, '10 Mb/s &
50
+ 100 Mb/s Management, Section 30,'
51
+ Supplement to ANSI/IEEE 802.3.
52
+
53
+ The following terms are used throughout this
54
+ MIB module. For complete formal definitions,
55
+ the IEEE 802.3 standards should be consulted
56
+ wherever possible:
57
+
58
+ System - A managed entity compliant with this
59
+ MIB, and incorporating at least one managed
60
+ 802.3 repeater.
61
+
62
+ Chassis - An enclosure for one managed repeater,
63
+ part of a managed repeater, or several managed
64
+ repeaters. It typically contains an integral
65
+ power supply and a variable number of available
66
+ module slots.
67
+
68
+ Repeater-unit - The portion of the repeater set
69
+ that is inboard of the physical media interfaces.
70
+ The physical media interfaces (MAUs, AUIs) may be
71
+ physically separated from the repeater-unit, or
72
+ they may be integrated into the same physical
73
+ package.
74
+
75
+ Trivial repeater-unit - An isolated port that can
76
+ gather statistics.
77
+
78
+ Group - A recommended, but optional, entity
79
+ defined by the IEEE 802.3 management standard,
80
+ in order to support a modular numbering scheme.
81
+ The classical example allows an implementor to
82
+ represent field-replaceable units as groups of
83
+ ports, with the port numbering matching the
84
+ modular hardware implementation.
85
+
86
+ System interconnect segment - An internal
87
+ segment allowing interconnection of ports
88
+ belonging to different physical entities
89
+ into the same logical manageable repeater.
90
+ Examples of implementation might be
91
+ backplane busses in modular hubs, or
92
+ chaining cables in stacks of hubs.
93
+ Stack - A scalable system that may include
94
+ managed repeaters, in which modularity is
95
+ achieved by interconnecting a number of
96
+ different chassis.
97
+
98
+ Module - A building block in a modular
99
+ chassis. It typically maps into one 'slot';
100
+ however, the range of configurations may be
101
+ very large, with several modules entering
102
+ one slot, or one module covering several
103
+ slots.""",
104
+ "revisions" : (
105
+ {
106
+ "date" : "1996-09-14 00:00",
107
+ "description" :
108
+ """[Revision added by libsmi due to a LAST-UPDATED clause.]""",
109
+ },
110
+ {
111
+ "date" : "1993-09-01 00:00",
112
+ "description" :
113
+ """Published as RFC 1516""",
114
+ },
115
+ {
116
+ "date" : "1992-10-01 00:00",
117
+ "description" :
118
+ """Published as RFC 1368""",
119
+ },
120
+ ),
121
+ "identity node" : "snmpRptrMod",
122
+ },
123
+
124
+ "imports" : (
125
+ {"module" : "SNMPv2-SMI", "name" : "Counter32"},
126
+ {"module" : "SNMPv2-SMI", "name" : "Counter64"},
127
+ {"module" : "SNMPv2-SMI", "name" : "Integer32"},
128
+ {"module" : "SNMPv2-SMI", "name" : "Gauge32"},
129
+ {"module" : "SNMPv2-SMI", "name" : "TimeTicks"},
130
+ {"module" : "SNMPv2-SMI", "name" : "OBJECT-TYPE"},
131
+ {"module" : "SNMPv2-SMI", "name" : "MODULE-IDENTITY"},
132
+ {"module" : "SNMPv2-SMI", "name" : "NOTIFICATION-TYPE"},
133
+ {"module" : "SNMPv2-SMI", "name" : "mib-2"},
134
+ {"module" : "SNMPv2-TC", "name" : "TimeStamp"},
135
+ {"module" : "SNMPv2-TC", "name" : "DisplayString"},
136
+ {"module" : "SNMPv2-TC", "name" : "MacAddress"},
137
+ {"module" : "SNMPv2-TC", "name" : "TEXTUAL-CONVENTION"},
138
+ {"module" : "SNMPv2-TC", "name" : "RowStatus"},
139
+ {"module" : "SNMPv2-TC", "name" : "TestAndIncr"},
140
+ {"module" : "SNMPv2-CONF", "name" : "OBJECT-GROUP"},
141
+ {"module" : "SNMPv2-CONF", "name" : "MODULE-COMPLIANCE"},
142
+ {"module" : "IF-MIB", "name" : "OwnerString"},
143
+ ),
144
+
145
+ "typedefs" : {
146
+ "OptMacAddr" : {
147
+ "basetype" : "OctetString",
148
+ "status" : "current",
149
+ "ranges" : [
150
+ {
151
+ "min" : "0",
152
+ "max" : "0"
153
+ },
154
+ {
155
+ "min" : "6",
156
+ "max" : "6"
157
+ },
158
+ ],
159
+ "range" : {
160
+ "min" : "0",
161
+ "max" : "6"
162
+ },
163
+ "format" : "1x:",
164
+ "description" :
165
+ """Either a 6 octet address in the `canonical'
166
+ order defined by IEEE 802.1a, i.e., as if it
167
+ were transmitted least significant bit first
168
+ if a value is available or a zero length string.""",
169
+ "reference" :
170
+ """See MacAddress in SNMPv2-TC. The only difference
171
+ is that a zero length string is allowed as a value
172
+ for OptMacAddr and not for MacAddress.""",
173
+ },
174
+ }, # typedefs
175
+
176
+ "nodes" : {
177
+ "snmpDot3RptrMgt" : {
178
+ "nodetype" : "node",
179
+ "moduleName" : "SNMP-REPEATER-MIB",
180
+ "oid" : "1.3.6.1.2.1.22",
181
+ }, # node
182
+ "rptrBasicPackage" : {
183
+ "nodetype" : "node",
184
+ "moduleName" : "SNMP-REPEATER-MIB",
185
+ "oid" : "1.3.6.1.2.1.22.1",
186
+ }, # node
187
+ "rptrRptrInfo" : {
188
+ "nodetype" : "node",
189
+ "moduleName" : "SNMP-REPEATER-MIB",
190
+ "oid" : "1.3.6.1.2.1.22.1.1",
191
+ }, # node
192
+ "rptrGroupCapacity" : {
193
+ "nodetype" : "scalar",
194
+ "moduleName" : "SNMP-REPEATER-MIB",
195
+ "oid" : "1.3.6.1.2.1.22.1.1.1",
196
+ "status" : "deprecated",
197
+ "syntax" : {
198
+ "type" : {
199
+ "basetype" : "Integer32",
200
+ "ranges" : [
201
+ {
202
+ "min" : "1",
203
+ "max" : "2147483647"
204
+ },
205
+ ],
206
+ "range" : {
207
+ "min" : "1",
208
+ "max" : "2147483647"
209
+ },
210
+ },
211
+ },
212
+ "access" : "readonly",
213
+ "description" :
214
+ """********* THIS OBJECT IS DEPRECATED **********
215
+
216
+ The rptrGroupCapacity is the number of groups
217
+ that can be contained within the repeater. Within
218
+ each managed repeater, the groups are uniquely
219
+ numbered in the range from 1 to rptrGroupCapacity.
220
+
221
+ Some groups may not be present in the repeater, in
222
+ which case the actual number of groups present
223
+ will be less than rptrGroupCapacity. The number
224
+ of groups present will never be greater than
225
+ rptrGroupCapacity.
226
+
227
+ Note: In practice, this will generally be the
228
+ number of field-replaceable units (i.e., modules,
229
+ cards, or boards) that can fit in the physical
230
+ repeater enclosure, and the group numbers will
231
+ correspond to numbers marked on the physical
232
+ enclosure.""",
233
+ "reference" :
234
+ """[IEEE 802.3 Mgt], 30.4.1.1.3,
235
+ aRepeaterGroupCapacity.""",
236
+ }, # scalar
237
+ "rptrOperStatus" : {
238
+ "nodetype" : "scalar",
239
+ "moduleName" : "SNMP-REPEATER-MIB",
240
+ "oid" : "1.3.6.1.2.1.22.1.1.2",
241
+ "status" : "deprecated",
242
+ "syntax" : {
243
+ "type" : {
244
+ "basetype" : "Enumeration",
245
+ "other" : {
246
+ "nodetype" : "namednumber",
247
+ "number" : "1"
248
+ },
249
+ "ok" : {
250
+ "nodetype" : "namednumber",
251
+ "number" : "2"
252
+ },
253
+ "rptrFailure" : {
254
+ "nodetype" : "namednumber",
255
+ "number" : "3"
256
+ },
257
+ "groupFailure" : {
258
+ "nodetype" : "namednumber",
259
+ "number" : "4"
260
+ },
261
+ "portFailure" : {
262
+ "nodetype" : "namednumber",
263
+ "number" : "5"
264
+ },
265
+ "generalFailure" : {
266
+ "nodetype" : "namednumber",
267
+ "number" : "6"
268
+ },
269
+ },
270
+ },
271
+ "access" : "readonly",
272
+ "description" :
273
+ """********* THIS OBJECT IS DEPRECATED **********
274
+
275
+ The rptrOperStatus object indicates the
276
+ operational state of the repeater. The
277
+ rptrHealthText object may be consulted for more
278
+ specific information about the state of the
279
+ repeater's health.
280
+
281
+ In the case of multiple kinds of failures (e.g.,
282
+ repeater failure and port failure), the value of
283
+ this attribute shall reflect the highest priority
284
+ failure in the following order, listed highest
285
+ priority first:
286
+
287
+ rptrFailure(3)
288
+ groupFailure(4)
289
+ portFailure(5)
290
+ generalFailure(6).""",
291
+ "reference" :
292
+ """[IEEE 802.3 Mgt], 30.4.1.1.5, aRepeaterHealthState.""",
293
+ }, # scalar
294
+ "rptrHealthText" : {
295
+ "nodetype" : "scalar",
296
+ "moduleName" : "SNMP-REPEATER-MIB",
297
+ "oid" : "1.3.6.1.2.1.22.1.1.3",
298
+ "status" : "deprecated",
299
+ "syntax" : {
300
+ "type" : {
301
+ "basetype" : "OctetString",
302
+ "parent module" : {
303
+ "name" : "SNMPv2-TC",
304
+ "type" : "DisplayString",
305
+ },
306
+ "ranges" : [
307
+ {
308
+ "min" : "0",
309
+ "max" : "255"
310
+ },
311
+ ],
312
+ "range" : {
313
+ "min" : "0",
314
+ "max" : "255"
315
+ },
316
+ },
317
+ },
318
+ "access" : "readonly",
319
+ "description" :
320
+ """********* THIS OBJECT IS DEPRECATED **********
321
+
322
+ The health text object is a text string that
323
+ provides information relevant to the operational
324
+ state of the repeater. Agents may use this string
325
+ to provide detailed information on current
326
+ failures, including how they were detected, and/or
327
+ instructions for problem resolution. The contents
328
+ are agent-specific.""",
329
+ "reference" :
330
+ """[IEEE 802.3 Mgt], 30.4.1.1.6, aRepeaterHealthText.""",
331
+ }, # scalar
332
+ "rptrReset" : {
333
+ "nodetype" : "scalar",
334
+ "moduleName" : "SNMP-REPEATER-MIB",
335
+ "oid" : "1.3.6.1.2.1.22.1.1.4",
336
+ "status" : "deprecated",
337
+ "syntax" : {
338
+ "type" : {
339
+ "basetype" : "Enumeration",
340
+ "noReset" : {
341
+ "nodetype" : "namednumber",
342
+ "number" : "1"
343
+ },
344
+ "reset" : {
345
+ "nodetype" : "namednumber",
346
+ "number" : "2"
347
+ },
348
+ },
349
+ },
350
+ "access" : "readwrite",
351
+ "description" :
352
+ """********* THIS OBJECT IS DEPRECATED **********
353
+
354
+ Setting this object to reset(2) causes a
355
+ transition to the START state of Fig 9-2 in
356
+ section 9 [IEEE 802.3 Std] for a 10Mb/s repeater,
357
+ and the START state of Fig 27-2 in section 27
358
+ of that standard for a 100Mb/s repeater.
359
+
360
+ Setting this object to noReset(1) has no effect.
361
+ The agent will always return the value noReset(1)
362
+ when this object is read.
363
+
364
+ After receiving a request to set this variable to
365
+ reset(2), the agent is allowed to delay the reset
366
+ for a short period. For example, the implementor
367
+ may choose to delay the reset long enough to allow
368
+ the SNMP response to be transmitted. In any
369
+ event, the SNMP response must be transmitted.
370
+
371
+ This action does not reset the management counters
372
+ defined in this document nor does it affect the
373
+ portAdminStatus parameters. Included in this
374
+ action is the execution of a disruptive Self-Test
375
+ with the following characteristics: a) The nature
376
+ of the tests is not specified. b) The test resets
377
+ the repeater but without affecting management
378
+ information about the repeater. c) The test does
379
+ not inject packets onto any segment. d) Packets
380
+ received during the test may or may not be
381
+ transferred. e) The test does not interfere with
382
+ management functions.
383
+
384
+ After performing this self-test, the agent will
385
+ update the repeater health information (including
386
+ rptrOperStatus and rptrHealthText), and send a
387
+ rptrHealth trap.""",
388
+ "reference" :
389
+ """[IEEE 802.3 Mgt], 30.4.1.2.1, acResetRepeater.""",
390
+ }, # scalar
391
+ "rptrNonDisruptTest" : {
392
+ "nodetype" : "scalar",
393
+ "moduleName" : "SNMP-REPEATER-MIB",
394
+ "oid" : "1.3.6.1.2.1.22.1.1.5",
395
+ "status" : "deprecated",
396
+ "syntax" : {
397
+ "type" : {
398
+ "basetype" : "Enumeration",
399
+ "noSelfTest" : {
400
+ "nodetype" : "namednumber",
401
+ "number" : "1"
402
+ },
403
+ "selfTest" : {
404
+ "nodetype" : "namednumber",
405
+ "number" : "2"
406
+ },
407
+ },
408
+ },
409
+ "access" : "readwrite",
410
+ "description" :
411
+ """********* THIS OBJECT IS DEPRECATED **********
412
+
413
+ Setting this object to selfTest(2) causes the
414
+ repeater to perform a agent-specific, non-
415
+ disruptive self-test that has the following
416
+ characteristics: a) The nature of the tests is
417
+ not specified. b) The test does not change the
418
+ state of the repeater or management information
419
+ about the repeater. c) The test does not inject
420
+ packets onto any segment. d) The test does not
421
+ prevent the relay of any packets. e) The test
422
+ does not interfere with management functions.
423
+
424
+ After performing this test, the agent will update
425
+ the repeater health information (including
426
+ rptrOperStatus and rptrHealthText) and send a
427
+ rptrHealth trap.
428
+
429
+ Note that this definition allows returning an
430
+ 'okay' result after doing a trivial test.
431
+
432
+ Setting this object to noSelfTest(1) has no
433
+ effect. The agent will always return the value
434
+ noSelfTest(1) when this object is read.""",
435
+ "reference" :
436
+ """[IEEE 802.3 Mgt], 30.4.1.2.2,
437
+ acExecuteNonDisruptiveSelfTest.""",
438
+ }, # scalar
439
+ "rptrTotalPartitionedPorts" : {
440
+ "nodetype" : "scalar",
441
+ "moduleName" : "SNMP-REPEATER-MIB",
442
+ "oid" : "1.3.6.1.2.1.22.1.1.6",
443
+ "status" : "deprecated",
444
+ "syntax" : {
445
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Gauge32"},
446
+ },
447
+ "access" : "readonly",
448
+ "description" :
449
+ """********* THIS OBJECT IS DEPRECATED **********
450
+
451
+ This object returns the total number of ports in
452
+ the repeater whose current state meets all three
453
+ of the following criteria: rptrPortOperStatus
454
+ does not have the value notPresent(3),
455
+ rptrPortAdminStatus is enabled(1), and
456
+ rptrPortAutoPartitionState is autoPartitioned(2).""",
457
+ }, # scalar
458
+ "rptrGroupInfo" : {
459
+ "nodetype" : "node",
460
+ "moduleName" : "SNMP-REPEATER-MIB",
461
+ "oid" : "1.3.6.1.2.1.22.1.2",
462
+ }, # node
463
+ "rptrGroupTable" : {
464
+ "nodetype" : "table",
465
+ "moduleName" : "SNMP-REPEATER-MIB",
466
+ "oid" : "1.3.6.1.2.1.22.1.2.1",
467
+ "status" : "current",
468
+ "description" :
469
+ """Table of descriptive and status information about
470
+ the groups of ports.""",
471
+ }, # table
472
+ "rptrGroupEntry" : {
473
+ "nodetype" : "row",
474
+ "moduleName" : "SNMP-REPEATER-MIB",
475
+ "oid" : "1.3.6.1.2.1.22.1.2.1.1",
476
+ "status" : "current",
477
+ "linkage" : [
478
+ "rptrGroupIndex",
479
+ ],
480
+ "description" :
481
+ """An entry in the table, containing information
482
+ about a single group of ports.""",
483
+ }, # row
484
+ "rptrGroupIndex" : {
485
+ "nodetype" : "column",
486
+ "moduleName" : "SNMP-REPEATER-MIB",
487
+ "oid" : "1.3.6.1.2.1.22.1.2.1.1.1",
488
+ "status" : "current",
489
+ "syntax" : {
490
+ "type" : {
491
+ "basetype" : "Integer32",
492
+ "ranges" : [
493
+ {
494
+ "min" : "1",
495
+ "max" : "2147483647"
496
+ },
497
+ ],
498
+ "range" : {
499
+ "min" : "1",
500
+ "max" : "2147483647"
501
+ },
502
+ },
503
+ },
504
+ "access" : "readonly",
505
+ "description" :
506
+ """This object identifies the group within the
507
+ system for which this entry contains
508
+ information.""",
509
+ "reference" :
510
+ """[IEEE 802.3 Mgt], 30.4.2.1.1, aGroupID.""",
511
+ }, # column
512
+ "rptrGroupDescr" : {
513
+ "nodetype" : "column",
514
+ "moduleName" : "SNMP-REPEATER-MIB",
515
+ "oid" : "1.3.6.1.2.1.22.1.2.1.1.2",
516
+ "status" : "deprecated",
517
+ "syntax" : {
518
+ "type" : {
519
+ "basetype" : "OctetString",
520
+ "parent module" : {
521
+ "name" : "SNMPv2-TC",
522
+ "type" : "DisplayString",
523
+ },
524
+ "ranges" : [
525
+ {
526
+ "min" : "0",
527
+ "max" : "255"
528
+ },
529
+ ],
530
+ "range" : {
531
+ "min" : "0",
532
+ "max" : "255"
533
+ },
534
+ },
535
+ },
536
+ "access" : "readonly",
537
+ "description" :
538
+ """********* THIS OBJECT IS DEPRECATED **********
539
+
540
+ A textual description of the group. This value
541
+ should include the full name and version
542
+ identification of the group's hardware type and
543
+ indicate how the group is differentiated from
544
+ other types of groups in the repeater. Plug-in
545
+ Module, Rev A' or 'Barney Rubble 10BASE-T 4-port
546
+ SIMM socket Version 2.1' are examples of valid
547
+ group descriptions.
548
+
549
+ It is mandatory that this only contain printable
550
+ ASCII characters.""",
551
+ }, # column
552
+ "rptrGroupObjectID" : {
553
+ "nodetype" : "column",
554
+ "moduleName" : "SNMP-REPEATER-MIB",
555
+ "oid" : "1.3.6.1.2.1.22.1.2.1.1.3",
556
+ "status" : "current",
557
+ "syntax" : {
558
+ "type" : { "module" :"", "name" : "ObjectIdentifier"},
559
+ },
560
+ "access" : "readonly",
561
+ "description" :
562
+ """The vendor's authoritative identification of the
563
+ group. This value may be allocated within the SMI
564
+ enterprises subtree (1.3.6.1.4.1) and provides a
565
+ straight-forward and unambiguous means for
566
+ determining what kind of group is being managed.
567
+
568
+ For example, this object could take the value
569
+ 1.3.6.1.4.1.4242.1.2.14 if vendor 'Flintstones,
570
+ Inc.' was assigned the subtree 1.3.6.1.4.1.4242,
571
+ and had assigned the identifier
572
+ 1.3.6.1.4.1.4242.1.2.14 to its 'Wilma Flintstone
573
+ 6-Port FOIRL Plug-in Module.'""",
574
+ }, # column
575
+ "rptrGroupOperStatus" : {
576
+ "nodetype" : "column",
577
+ "moduleName" : "SNMP-REPEATER-MIB",
578
+ "oid" : "1.3.6.1.2.1.22.1.2.1.1.4",
579
+ "status" : "current",
580
+ "syntax" : {
581
+ "type" : {
582
+ "basetype" : "Enumeration",
583
+ "other" : {
584
+ "nodetype" : "namednumber",
585
+ "number" : "1"
586
+ },
587
+ "operational" : {
588
+ "nodetype" : "namednumber",
589
+ "number" : "2"
590
+ },
591
+ "malfunctioning" : {
592
+ "nodetype" : "namednumber",
593
+ "number" : "3"
594
+ },
595
+ "notPresent" : {
596
+ "nodetype" : "namednumber",
597
+ "number" : "4"
598
+ },
599
+ "underTest" : {
600
+ "nodetype" : "namednumber",
601
+ "number" : "5"
602
+ },
603
+ "resetInProgress" : {
604
+ "nodetype" : "namednumber",
605
+ "number" : "6"
606
+ },
607
+ },
608
+ },
609
+ "access" : "readonly",
610
+ "description" :
611
+ """An object that indicates the operational status
612
+ of the group.
613
+
614
+ A status of notPresent(4) indicates that the group
615
+ is temporarily or permanently physically and/or
616
+ logically not a part of the repeater. It is an
617
+ implementation-specific matter as to whether the
618
+ agent effectively removes notPresent entries from
619
+ the table.
620
+
621
+ A status of operational(2) indicates that the
622
+ group is functioning, and a status of
623
+ malfunctioning(3) indicates that the group is
624
+ malfunctioning in some way.""",
625
+ }, # column
626
+ "rptrGroupLastOperStatusChange" : {
627
+ "nodetype" : "column",
628
+ "moduleName" : "SNMP-REPEATER-MIB",
629
+ "oid" : "1.3.6.1.2.1.22.1.2.1.1.5",
630
+ "status" : "deprecated",
631
+ "syntax" : {
632
+ "type" : { "module" :"SNMPv2-SMI", "name" : "TimeTicks"},
633
+ },
634
+ "access" : "readonly",
635
+ "description" :
636
+ """********* THIS OBJECT IS DEPRECATED **********
637
+
638
+ An object that contains the value of sysUpTime at
639
+ the time when the last of the following occurred:
640
+ 1) the agent cold- or warm-started;
641
+ 2) the row for the group was created (such
642
+ as when the group was added to the system); or
643
+ 3) the value of rptrGroupOperStatus for the
644
+ group changed.
645
+
646
+ A value of zero indicates that the group's
647
+ operational status has not changed since the agent
648
+ last restarted.""",
649
+ }, # column
650
+ "rptrGroupPortCapacity" : {
651
+ "nodetype" : "column",
652
+ "moduleName" : "SNMP-REPEATER-MIB",
653
+ "oid" : "1.3.6.1.2.1.22.1.2.1.1.6",
654
+ "status" : "current",
655
+ "syntax" : {
656
+ "type" : {
657
+ "basetype" : "Integer32",
658
+ "ranges" : [
659
+ {
660
+ "min" : "1",
661
+ "max" : "2147483647"
662
+ },
663
+ ],
664
+ "range" : {
665
+ "min" : "1",
666
+ "max" : "2147483647"
667
+ },
668
+ },
669
+ },
670
+ "access" : "readonly",
671
+ "description" :
672
+ """The rptrGroupPortCapacity is the number of ports
673
+ that can be contained within the group. Valid
674
+ range is 1-2147483647. Within each group, the
675
+ ports are uniquely numbered in the range from 1 to
676
+ rptrGroupPortCapacity.
677
+
678
+ Some ports may not be present in the system, in
679
+ which case the actual number of ports present
680
+ will be less than the value of rptrGroupPortCapacity.
681
+ The number of ports present in the group will never
682
+ be greater than the value of rptrGroupPortCapacity.
683
+
684
+ Note: In practice, this will generally be the
685
+ number of ports on a module, card, or board, and
686
+ the port numbers will correspond to numbers marked
687
+ on the physical embodiment.""",
688
+ "reference" :
689
+ """IEEE 802.3 Mgt, 30.4.2.1.2, aGroupPortCapacity.""",
690
+ }, # column
691
+ "rptrPortInfo" : {
692
+ "nodetype" : "node",
693
+ "moduleName" : "SNMP-REPEATER-MIB",
694
+ "oid" : "1.3.6.1.2.1.22.1.3",
695
+ }, # node
696
+ "rptrPortTable" : {
697
+ "nodetype" : "table",
698
+ "moduleName" : "SNMP-REPEATER-MIB",
699
+ "oid" : "1.3.6.1.2.1.22.1.3.1",
700
+ "status" : "current",
701
+ "description" :
702
+ """Table of descriptive and status information about
703
+ the repeater ports in the system. The number of
704
+ entries is independent of the number of repeaters
705
+ in the managed system.""",
706
+ }, # table
707
+ "rptrPortEntry" : {
708
+ "nodetype" : "row",
709
+ "moduleName" : "SNMP-REPEATER-MIB",
710
+ "oid" : "1.3.6.1.2.1.22.1.3.1.1",
711
+ "status" : "current",
712
+ "linkage" : [
713
+ "rptrPortGroupIndex",
714
+ "rptrPortIndex",
715
+ ],
716
+ "description" :
717
+ """An entry in the table, containing information
718
+ about a single port.""",
719
+ }, # row
720
+ "rptrPortGroupIndex" : {
721
+ "nodetype" : "column",
722
+ "moduleName" : "SNMP-REPEATER-MIB",
723
+ "oid" : "1.3.6.1.2.1.22.1.3.1.1.1",
724
+ "status" : "current",
725
+ "syntax" : {
726
+ "type" : {
727
+ "basetype" : "Integer32",
728
+ "ranges" : [
729
+ {
730
+ "min" : "1",
731
+ "max" : "2147483647"
732
+ },
733
+ ],
734
+ "range" : {
735
+ "min" : "1",
736
+ "max" : "2147483647"
737
+ },
738
+ },
739
+ },
740
+ "access" : "readonly",
741
+ "description" :
742
+ """This object identifies the group containing the
743
+ port for which this entry contains information.""",
744
+ }, # column
745
+ "rptrPortIndex" : {
746
+ "nodetype" : "column",
747
+ "moduleName" : "SNMP-REPEATER-MIB",
748
+ "oid" : "1.3.6.1.2.1.22.1.3.1.1.2",
749
+ "status" : "current",
750
+ "syntax" : {
751
+ "type" : {
752
+ "basetype" : "Integer32",
753
+ "ranges" : [
754
+ {
755
+ "min" : "1",
756
+ "max" : "2147483647"
757
+ },
758
+ ],
759
+ "range" : {
760
+ "min" : "1",
761
+ "max" : "2147483647"
762
+ },
763
+ },
764
+ },
765
+ "access" : "readonly",
766
+ "description" :
767
+ """This object identifies the port within the group
768
+ for which this entry contains information. This
769
+ identifies the port independently from the repeater
770
+ it may be attached to. The numbering scheme for
771
+ ports is implementation specific; however, this
772
+ value can never be greater than
773
+ rptrGroupPortCapacity for the associated group.""",
774
+ "reference" :
775
+ """[IEEE 802.3 Mgt], 30.4.3.1.1, aPortID.""",
776
+ }, # column
777
+ "rptrPortAdminStatus" : {
778
+ "nodetype" : "column",
779
+ "moduleName" : "SNMP-REPEATER-MIB",
780
+ "oid" : "1.3.6.1.2.1.22.1.3.1.1.3",
781
+ "status" : "current",
782
+ "syntax" : {
783
+ "type" : {
784
+ "basetype" : "Enumeration",
785
+ "enabled" : {
786
+ "nodetype" : "namednumber",
787
+ "number" : "1"
788
+ },
789
+ "disabled" : {
790
+ "nodetype" : "namednumber",
791
+ "number" : "2"
792
+ },
793
+ },
794
+ },
795
+ "access" : "readwrite",
796
+ "description" :
797
+ """Setting this object to disabled(2) disables the
798
+ port. A disabled port neither transmits nor
799
+ receives. Once disabled, a port must be
800
+ explicitly enabled to restore operation. A port
801
+ which is disabled when power is lost or when a
802
+ reset is exerted shall remain disabled when normal
803
+ operation resumes.
804
+
805
+ The admin status takes precedence over auto-
806
+ partition and functionally operates between the
807
+ auto-partition mechanism and the AUI/PMA.
808
+
809
+ Setting this object to enabled(1) enables the port
810
+ and exerts a BEGIN on the port's auto-partition
811
+ state machine.
812
+
813
+ (In effect, when a port is disabled, the value of
814
+ rptrPortAutoPartitionState for that port is frozen
815
+ until the port is next enabled. When the port
816
+ becomes enabled, the rptrPortAutoPartitionState
817
+ becomes notAutoPartitioned(1), regardless of its
818
+ pre-disabling state.)""",
819
+ "reference" :
820
+ """[IEEE 802.3 Mgt], 30.4.3.1.2, aPortAdminState
821
+ and 30.4.3.2.1, acPortAdminControl.""",
822
+ }, # column
823
+ "rptrPortAutoPartitionState" : {
824
+ "nodetype" : "column",
825
+ "moduleName" : "SNMP-REPEATER-MIB",
826
+ "oid" : "1.3.6.1.2.1.22.1.3.1.1.4",
827
+ "status" : "current",
828
+ "syntax" : {
829
+ "type" : {
830
+ "basetype" : "Enumeration",
831
+ "notAutoPartitioned" : {
832
+ "nodetype" : "namednumber",
833
+ "number" : "1"
834
+ },
835
+ "autoPartitioned" : {
836
+ "nodetype" : "namednumber",
837
+ "number" : "2"
838
+ },
839
+ },
840
+ },
841
+ "access" : "readonly",
842
+ "description" :
843
+ """The autoPartitionState flag indicates whether the
844
+ port is currently partitioned by the repeater's
845
+ auto-partition protection.
846
+
847
+ The conditions that cause port partitioning are
848
+ specified in partition state machine in Sections
849
+ 9 and 27 of [IEEE 802.3 Std]. They are not
850
+ differentiated here.""",
851
+ "reference" :
852
+ """[IEEE 802.3 Mgt], 30.4.3.1.3, aAutoPartitionState.""",
853
+ }, # column
854
+ "rptrPortOperStatus" : {
855
+ "nodetype" : "column",
856
+ "moduleName" : "SNMP-REPEATER-MIB",
857
+ "oid" : "1.3.6.1.2.1.22.1.3.1.1.5",
858
+ "status" : "current",
859
+ "syntax" : {
860
+ "type" : {
861
+ "basetype" : "Enumeration",
862
+ "operational" : {
863
+ "nodetype" : "namednumber",
864
+ "number" : "1"
865
+ },
866
+ "notOperational" : {
867
+ "nodetype" : "namednumber",
868
+ "number" : "2"
869
+ },
870
+ "notPresent" : {
871
+ "nodetype" : "namednumber",
872
+ "number" : "3"
873
+ },
874
+ },
875
+ },
876
+ "access" : "readonly",
877
+ "description" :
878
+ """This object indicates the port's operational
879
+ status. The notPresent(3) status indicates the
880
+ port is physically removed (note this may or may
881
+ not be possible depending on the type of port.)
882
+ The operational(1) status indicates that the port
883
+ is enabled (see rptrPortAdminStatus) and working,
884
+ even though it might be auto-partitioned (see
885
+ rptrPortAutoPartitionState).
886
+
887
+ If this object has the value operational(1) and
888
+ rptrPortAdminStatus is set to disabled(2), it is
889
+ expected that this object's value will soon change
890
+ to notOperational(2).""",
891
+ }, # column
892
+ "rptrPortRptrId" : {
893
+ "nodetype" : "column",
894
+ "moduleName" : "SNMP-REPEATER-MIB",
895
+ "oid" : "1.3.6.1.2.1.22.1.3.1.1.6",
896
+ "status" : "current",
897
+ "syntax" : {
898
+ "type" : {
899
+ "basetype" : "Integer32",
900
+ "ranges" : [
901
+ {
902
+ "min" : "0",
903
+ "max" : "2147483647"
904
+ },
905
+ ],
906
+ "range" : {
907
+ "min" : "0",
908
+ "max" : "2147483647"
909
+ },
910
+ },
911
+ },
912
+ "access" : "readonly",
913
+ "description" :
914
+ """This object identifies the repeater to
915
+ which this port belongs. The repeater
916
+ identified by a particular value of this object
917
+ is the same as that identified by the same
918
+ value of rptrInfoId. A value of zero
919
+ indicates that this port currently is not
920
+ a member of any repeater.""",
921
+ }, # column
922
+ "rptrAllRptrInfo" : {
923
+ "nodetype" : "node",
924
+ "moduleName" : "SNMP-REPEATER-MIB",
925
+ "oid" : "1.3.6.1.2.1.22.1.4",
926
+ }, # node
927
+ "rptrInfoTable" : {
928
+ "nodetype" : "table",
929
+ "moduleName" : "SNMP-REPEATER-MIB",
930
+ "oid" : "1.3.6.1.2.1.22.1.4.1",
931
+ "status" : "current",
932
+ "description" :
933
+ """A table of information about each
934
+ non-trivial repeater. The number of entries
935
+ depends on the physical configuration of the
936
+ managed system.""",
937
+ }, # table
938
+ "rptrInfoEntry" : {
939
+ "nodetype" : "row",
940
+ "moduleName" : "SNMP-REPEATER-MIB",
941
+ "oid" : "1.3.6.1.2.1.22.1.4.1.1",
942
+ "status" : "current",
943
+ "linkage" : [
944
+ "rptrInfoId",
945
+ ],
946
+ "description" :
947
+ """An entry in the table, containing information
948
+ about a single non-trivial repeater.""",
949
+ }, # row
950
+ "rptrInfoId" : {
951
+ "nodetype" : "column",
952
+ "moduleName" : "SNMP-REPEATER-MIB",
953
+ "oid" : "1.3.6.1.2.1.22.1.4.1.1.1",
954
+ "status" : "current",
955
+ "syntax" : {
956
+ "type" : {
957
+ "basetype" : "Integer32",
958
+ "ranges" : [
959
+ {
960
+ "min" : "1",
961
+ "max" : "2147483647"
962
+ },
963
+ ],
964
+ "range" : {
965
+ "min" : "1",
966
+ "max" : "2147483647"
967
+ },
968
+ },
969
+ },
970
+ "access" : "readonly",
971
+ "description" :
972
+ """This object identifies the repeater for which
973
+ this entry contains information.""",
974
+ }, # column
975
+ "rptrInfoRptrType" : {
976
+ "nodetype" : "column",
977
+ "moduleName" : "SNMP-REPEATER-MIB",
978
+ "oid" : "1.3.6.1.2.1.22.1.4.1.1.2",
979
+ "status" : "current",
980
+ "syntax" : {
981
+ "type" : {
982
+ "basetype" : "Enumeration",
983
+ "other" : {
984
+ "nodetype" : "namednumber",
985
+ "number" : "1"
986
+ },
987
+ "tenMb" : {
988
+ "nodetype" : "namednumber",
989
+ "number" : "2"
990
+ },
991
+ "onehundredMbClassI" : {
992
+ "nodetype" : "namednumber",
993
+ "number" : "3"
994
+ },
995
+ "onehundredMbClassII" : {
996
+ "nodetype" : "namednumber",
997
+ "number" : "4"
998
+ },
999
+ },
1000
+ },
1001
+ "access" : "readonly",
1002
+ "description" :
1003
+ """The rptrInfoRptrType returns a value that identifies
1004
+ the CSMA/CD repeater type.""",
1005
+ "reference" :
1006
+ """[IEEE 802.3 Mgt], 30.4.1.1.2, aRepeaterType.""",
1007
+ }, # column
1008
+ "rptrInfoOperStatus" : {
1009
+ "nodetype" : "column",
1010
+ "moduleName" : "SNMP-REPEATER-MIB",
1011
+ "oid" : "1.3.6.1.2.1.22.1.4.1.1.3",
1012
+ "status" : "current",
1013
+ "syntax" : {
1014
+ "type" : {
1015
+ "basetype" : "Enumeration",
1016
+ "other" : {
1017
+ "nodetype" : "namednumber",
1018
+ "number" : "1"
1019
+ },
1020
+ "ok" : {
1021
+ "nodetype" : "namednumber",
1022
+ "number" : "2"
1023
+ },
1024
+ "failure" : {
1025
+ "nodetype" : "namednumber",
1026
+ "number" : "3"
1027
+ },
1028
+ },
1029
+ },
1030
+ "access" : "readonly",
1031
+ "description" :
1032
+ """The rptrInfoOperStatus object indicates the
1033
+ operational state of the repeater.""",
1034
+ "reference" :
1035
+ """[IEEE 802.3 Mgt], 30.4.1.1.5, aRepeaterHealthState.""",
1036
+ }, # column
1037
+ "rptrInfoReset" : {
1038
+ "nodetype" : "column",
1039
+ "moduleName" : "SNMP-REPEATER-MIB",
1040
+ "oid" : "1.3.6.1.2.1.22.1.4.1.1.4",
1041
+ "status" : "current",
1042
+ "syntax" : {
1043
+ "type" : {
1044
+ "basetype" : "Enumeration",
1045
+ "noReset" : {
1046
+ "nodetype" : "namednumber",
1047
+ "number" : "1"
1048
+ },
1049
+ "reset" : {
1050
+ "nodetype" : "namednumber",
1051
+ "number" : "2"
1052
+ },
1053
+ },
1054
+ },
1055
+ "access" : "readwrite",
1056
+ "description" :
1057
+ """Setting this object to reset(2) causes a
1058
+ transition to the START state of Fig 9-2 in
1059
+ section 9 [IEEE 802.3 Std] for a 10Mb/s repeater,
1060
+ and to the START state of Fig 27-2 in section 27
1061
+ of that standard for a 100Mb/s repeater.
1062
+
1063
+ Setting this object to noReset(1) has no effect.
1064
+ The agent will always return the value noReset(1)
1065
+ when this object is read.
1066
+
1067
+ After receiving a request to set this variable to
1068
+ reset(2), the agent is allowed to delay the reset
1069
+ for a short period. For example, the implementor
1070
+ may choose to delay the reset long enough to allow
1071
+ the SNMP response to be transmitted. In any
1072
+ event, the SNMP response must be transmitted.
1073
+
1074
+ This action does not reset the management counters
1075
+ defined in this document nor does it affect the
1076
+ portAdminStatus parameters. Included in this
1077
+ action is the execution of a disruptive Self-Test
1078
+ with the following characteristics: a) The nature
1079
+ of the tests is not specified. b) The test resets
1080
+ the repeater but without affecting management
1081
+ information about the repeater. c) The test does
1082
+ not inject packets onto any segment. d) Packets
1083
+ received during the test may or may not be
1084
+ transferred. e) The test does not interfere with
1085
+ management functions.
1086
+
1087
+ After performing this self-test, the agent will
1088
+ update the repeater health information (including
1089
+ rptrInfoOperStatus), and send a rptrInfoResetEvent
1090
+ notification.""",
1091
+ "reference" :
1092
+ """[IEEE 802.3 Mgt], 30.4.1.2.1, acResetRepeater.""",
1093
+ }, # column
1094
+ "rptrInfoPartitionedPorts" : {
1095
+ "nodetype" : "column",
1096
+ "moduleName" : "SNMP-REPEATER-MIB",
1097
+ "oid" : "1.3.6.1.2.1.22.1.4.1.1.5",
1098
+ "status" : "current",
1099
+ "syntax" : {
1100
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Gauge32"},
1101
+ },
1102
+ "access" : "readonly",
1103
+ "description" :
1104
+ """This object returns the total number of ports in
1105
+ the repeater whose current state meets all three
1106
+ of the following criteria: rptrPortOperStatus
1107
+ does not have the value notPresent(3),
1108
+ rptrPortAdminStatus is enabled(1), and
1109
+ rptrPortAutoPartitionState is autoPartitioned(2).""",
1110
+ }, # column
1111
+ "rptrInfoLastChange" : {
1112
+ "nodetype" : "column",
1113
+ "moduleName" : "SNMP-REPEATER-MIB",
1114
+ "oid" : "1.3.6.1.2.1.22.1.4.1.1.6",
1115
+ "status" : "current",
1116
+ "syntax" : {
1117
+ "type" : { "module" :"SNMPv2-TC", "name" : "TimeStamp"},
1118
+ },
1119
+ "access" : "readonly",
1120
+ "description" :
1121
+ """The value of sysUpTime when any of the following
1122
+ conditions occurred:
1123
+ 1) agent cold- or warm-started;
1124
+ 2) this instance of repeater was created
1125
+ (such as when a device or module was
1126
+ added to the system);
1127
+ 3) a change in the value of rptrInfoOperStatus;
1128
+ 4) ports were added or removed as members of
1129
+ the repeater; or
1130
+ 5) any of the counters associated with this
1131
+ repeater had a discontinuity.""",
1132
+ }, # column
1133
+ "rptrMonitorPackage" : {
1134
+ "nodetype" : "node",
1135
+ "moduleName" : "SNMP-REPEATER-MIB",
1136
+ "oid" : "1.3.6.1.2.1.22.2",
1137
+ }, # node
1138
+ "rptrMonitorRptrInfo" : {
1139
+ "nodetype" : "node",
1140
+ "moduleName" : "SNMP-REPEATER-MIB",
1141
+ "oid" : "1.3.6.1.2.1.22.2.1",
1142
+ }, # node
1143
+ "rptrMonitorTransmitCollisions" : {
1144
+ "nodetype" : "scalar",
1145
+ "moduleName" : "SNMP-REPEATER-MIB",
1146
+ "oid" : "1.3.6.1.2.1.22.2.1.1",
1147
+ "status" : "deprecated",
1148
+ "syntax" : {
1149
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
1150
+ },
1151
+ "access" : "readonly",
1152
+ "description" :
1153
+ """********* THIS OBJECT IS DEPRECATED **********
1154
+
1155
+ For a clause 9 (10Mb/s) repeater, this counter
1156
+ is incremented every time the repeater state
1157
+ machine enters the TRANSMIT COLLISION state
1158
+ from any state other than ONE PORT LEFT
1159
+ (Ref: Fig 9-2 [IEEE 802.3 Std]).
1160
+
1161
+ For a clause 27 repeater, this counter is
1162
+ incremented every time the repeater core state
1163
+ diagram enters the Jam state as a result of
1164
+ Activity(ALL) > 1 (fig 27-2 [IEEE 802.3 Std]).
1165
+ The approximate minimum time for rollover of this
1166
+ counter is 16 hours in a 10Mb/s repeater and 1.6
1167
+ hours in a 100Mb/s repeater.""",
1168
+ "reference" :
1169
+ """[IEEE 802.3 Mgt], 30.4.1.1.8, aTransmitCollisions.""",
1170
+ }, # scalar
1171
+ "rptrMonitorGroupInfo" : {
1172
+ "nodetype" : "node",
1173
+ "moduleName" : "SNMP-REPEATER-MIB",
1174
+ "oid" : "1.3.6.1.2.1.22.2.2",
1175
+ }, # node
1176
+ "rptrMonitorGroupTable" : {
1177
+ "nodetype" : "table",
1178
+ "moduleName" : "SNMP-REPEATER-MIB",
1179
+ "oid" : "1.3.6.1.2.1.22.2.2.1",
1180
+ "status" : "deprecated",
1181
+ "description" :
1182
+ """********* THIS OBJECT IS DEPRECATED **********
1183
+
1184
+ Table of performance and error statistics for the
1185
+ groups within the repeater. The number of entries
1186
+ is the same as that in the rptrGroupTable.""",
1187
+ }, # table
1188
+ "rptrMonitorGroupEntry" : {
1189
+ "nodetype" : "row",
1190
+ "moduleName" : "SNMP-REPEATER-MIB",
1191
+ "oid" : "1.3.6.1.2.1.22.2.2.1.1",
1192
+ "status" : "deprecated",
1193
+ "linkage" : [
1194
+ "rptrMonitorGroupIndex",
1195
+ ],
1196
+ "description" :
1197
+ """********* THIS OBJECT IS DEPRECATED **********
1198
+
1199
+ An entry in the table, containing total
1200
+ performance and error statistics for a single
1201
+ group. Regular retrieval of the information in
1202
+ this table provides a means of tracking the
1203
+ performance and health of the networked devices
1204
+ attached to this group's ports.
1205
+
1206
+ The counters in this table are redundant in the
1207
+ sense that they are the summations of information
1208
+ already available through other objects. However,
1209
+ these sums provide a considerable optimization of
1210
+ network management traffic over the otherwise
1211
+ necessary retrieval of the individual counters
1212
+ included in each sum.
1213
+
1214
+ Note: Group-level counters are
1215
+ deprecated in this MIB. It is recommended
1216
+ that management applications instead use
1217
+ the repeater-level counters contained in
1218
+ the rptrMonTable.""",
1219
+ }, # row
1220
+ "rptrMonitorGroupIndex" : {
1221
+ "nodetype" : "column",
1222
+ "moduleName" : "SNMP-REPEATER-MIB",
1223
+ "oid" : "1.3.6.1.2.1.22.2.2.1.1.1",
1224
+ "status" : "deprecated",
1225
+ "syntax" : {
1226
+ "type" : {
1227
+ "basetype" : "Integer32",
1228
+ "ranges" : [
1229
+ {
1230
+ "min" : "1",
1231
+ "max" : "2147483647"
1232
+ },
1233
+ ],
1234
+ "range" : {
1235
+ "min" : "1",
1236
+ "max" : "2147483647"
1237
+ },
1238
+ },
1239
+ },
1240
+ "access" : "readonly",
1241
+ "description" :
1242
+ """********* THIS OBJECT IS DEPRECATED **********
1243
+
1244
+ This object identifies the group within the
1245
+ repeater for which this entry contains
1246
+ information.""",
1247
+ }, # column
1248
+ "rptrMonitorGroupTotalFrames" : {
1249
+ "nodetype" : "column",
1250
+ "moduleName" : "SNMP-REPEATER-MIB",
1251
+ "oid" : "1.3.6.1.2.1.22.2.2.1.1.2",
1252
+ "status" : "deprecated",
1253
+ "syntax" : {
1254
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
1255
+ },
1256
+ "access" : "readonly",
1257
+ "description" :
1258
+ """********* THIS OBJECT IS DEPRECATED **********
1259
+
1260
+ The total number of frames of valid frame length
1261
+ that have been received on the ports in this group
1262
+ and for which the FCSError and CollisionEvent
1263
+ signals were not asserted. This counter is the
1264
+ summation of the values of the
1265
+ rptrMonitorPortReadableFrames counters for all of
1266
+ the ports in the group.
1267
+
1268
+ This statistic provides one of the parameters
1269
+ necessary for obtaining the packet error rate.
1270
+ The approximate minimum time for rollover of this
1271
+ counter is 80 hours in a 10Mb/s repeater.""",
1272
+ }, # column
1273
+ "rptrMonitorGroupTotalOctets" : {
1274
+ "nodetype" : "column",
1275
+ "moduleName" : "SNMP-REPEATER-MIB",
1276
+ "oid" : "1.3.6.1.2.1.22.2.2.1.1.3",
1277
+ "status" : "deprecated",
1278
+ "syntax" : {
1279
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
1280
+ },
1281
+ "access" : "readonly",
1282
+ "description" :
1283
+ """********* THIS OBJECT IS DEPRECATED **********
1284
+
1285
+ The total number of octets contained in the valid
1286
+ frames that have been received on the ports in
1287
+ this group. This counter is the summation of the
1288
+ values of the rptrMonitorPortReadableOctets
1289
+ counters for all of the ports in the group.
1290
+
1291
+ This statistic provides an indicator of the total
1292
+ data transferred. The approximate minimum time
1293
+ for rollover of this counter is 58 minutes in a
1294
+ 10Mb/s repeater.""",
1295
+ }, # column
1296
+ "rptrMonitorGroupTotalErrors" : {
1297
+ "nodetype" : "column",
1298
+ "moduleName" : "SNMP-REPEATER-MIB",
1299
+ "oid" : "1.3.6.1.2.1.22.2.2.1.1.4",
1300
+ "status" : "deprecated",
1301
+ "syntax" : {
1302
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
1303
+ },
1304
+ "access" : "readonly",
1305
+ "description" :
1306
+ """********* THIS OBJECT IS DEPRECATED **********
1307
+
1308
+ The total number of errors which have occurred on
1309
+ all of the ports in this group. This counter is
1310
+ the summation of the values of the
1311
+ rptrMonitorPortTotalErrors counters for all of the
1312
+ ports in the group.""",
1313
+ }, # column
1314
+ "rptrMonitorPortInfo" : {
1315
+ "nodetype" : "node",
1316
+ "moduleName" : "SNMP-REPEATER-MIB",
1317
+ "oid" : "1.3.6.1.2.1.22.2.3",
1318
+ }, # node
1319
+ "rptrMonitorPortTable" : {
1320
+ "nodetype" : "table",
1321
+ "moduleName" : "SNMP-REPEATER-MIB",
1322
+ "oid" : "1.3.6.1.2.1.22.2.3.1",
1323
+ "status" : "current",
1324
+ "description" :
1325
+ """Table of performance and error statistics for the
1326
+ ports. The number of entries is the same as that
1327
+ in the rptrPortTable.
1328
+
1329
+ The columnar object rptrMonitorPortLastChange
1330
+ is used to indicate possible discontinuities
1331
+ of counter type columnar objects in the table.""",
1332
+ }, # table
1333
+ "rptrMonitorPortEntry" : {
1334
+ "nodetype" : "row",
1335
+ "moduleName" : "SNMP-REPEATER-MIB",
1336
+ "oid" : "1.3.6.1.2.1.22.2.3.1.1",
1337
+ "status" : "current",
1338
+ "linkage" : [
1339
+ "rptrMonitorPortGroupIndex",
1340
+ "rptrMonitorPortIndex",
1341
+ ],
1342
+ "description" :
1343
+ """An entry in the table, containing performance and
1344
+ error statistics for a single port.""",
1345
+ }, # row
1346
+ "rptrMonitorPortGroupIndex" : {
1347
+ "nodetype" : "column",
1348
+ "moduleName" : "SNMP-REPEATER-MIB",
1349
+ "oid" : "1.3.6.1.2.1.22.2.3.1.1.1",
1350
+ "status" : "current",
1351
+ "syntax" : {
1352
+ "type" : {
1353
+ "basetype" : "Integer32",
1354
+ "ranges" : [
1355
+ {
1356
+ "min" : "1",
1357
+ "max" : "2147483647"
1358
+ },
1359
+ ],
1360
+ "range" : {
1361
+ "min" : "1",
1362
+ "max" : "2147483647"
1363
+ },
1364
+ },
1365
+ },
1366
+ "access" : "readonly",
1367
+ "description" :
1368
+ """This object identifies the group containing the
1369
+ port for which this entry contains information.""",
1370
+ }, # column
1371
+ "rptrMonitorPortIndex" : {
1372
+ "nodetype" : "column",
1373
+ "moduleName" : "SNMP-REPEATER-MIB",
1374
+ "oid" : "1.3.6.1.2.1.22.2.3.1.1.2",
1375
+ "status" : "current",
1376
+ "syntax" : {
1377
+ "type" : {
1378
+ "basetype" : "Integer32",
1379
+ "ranges" : [
1380
+ {
1381
+ "min" : "1",
1382
+ "max" : "2147483647"
1383
+ },
1384
+ ],
1385
+ "range" : {
1386
+ "min" : "1",
1387
+ "max" : "2147483647"
1388
+ },
1389
+ },
1390
+ },
1391
+ "access" : "readonly",
1392
+ "description" :
1393
+ """This object identifies the port within the group
1394
+ for which this entry contains information.""",
1395
+ "reference" :
1396
+ """[IEEE 802.3 Mgt], 30.4.3.1.1, aPortID.""",
1397
+ }, # column
1398
+ "rptrMonitorPortReadableFrames" : {
1399
+ "nodetype" : "column",
1400
+ "moduleName" : "SNMP-REPEATER-MIB",
1401
+ "oid" : "1.3.6.1.2.1.22.2.3.1.1.3",
1402
+ "status" : "current",
1403
+ "syntax" : {
1404
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
1405
+ },
1406
+ "access" : "readonly",
1407
+ "description" :
1408
+ """This object is the number of frames of valid
1409
+ frame length that have been received on this port.
1410
+ This counter is incremented by one for each frame
1411
+ received on this port whose OctetCount is greater
1412
+ than or equal to minFrameSize and less than or
1413
+ equal to maxFrameSize (Ref: IEEE 802.3 Std,
1414
+ 4.4.2.1) and for which the FCSError and
1415
+ CollisionEvent signals are not asserted.
1416
+
1417
+ A discontinuity may occur in the value
1418
+ when the value of object
1419
+ rptrMonitorPortLastChange changes.
1420
+
1421
+ This statistic provides one of the parameters
1422
+ necessary for obtaining the packet error rate.
1423
+ The approximate minimum time for rollover of this
1424
+ counter is 80 hours at 10Mb/s.""",
1425
+ "reference" :
1426
+ """[IEEE 802.3 Mgt], 30.4.3.1.4, aReadableFrames.""",
1427
+ }, # column
1428
+ "rptrMonitorPortReadableOctets" : {
1429
+ "nodetype" : "column",
1430
+ "moduleName" : "SNMP-REPEATER-MIB",
1431
+ "oid" : "1.3.6.1.2.1.22.2.3.1.1.4",
1432
+ "status" : "current",
1433
+ "syntax" : {
1434
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
1435
+ },
1436
+ "access" : "readonly",
1437
+ "description" :
1438
+ """This object is the number of octets contained in
1439
+ valid frames that have been received on this port.
1440
+ This counter is incremented by OctetCount for each
1441
+ frame received on this port which has been
1442
+ determined to be a readable frame (i.e., including
1443
+ FCS octets but excluding framing bits and dribble
1444
+ bits).
1445
+
1446
+ A discontinuity may occur in the value
1447
+ when the value of object
1448
+ rptrMonitorPortLastChange changes.
1449
+
1450
+ This statistic provides an indicator of the total
1451
+ data transferred. The approximate minimum time
1452
+ for rollover of this counter in a 10Mb/s repeater
1453
+ is 58 minutes.
1454
+
1455
+ For ports receiving traffic at a maximum rate in
1456
+ a 100Mb/s repeater, this counter can roll over
1457
+ in less than 6 minutes. Since that amount of time
1458
+ could be less than a management station's poll cycle
1459
+ time, in order to avoid a loss of information a
1460
+ management station is advised to also poll the
1461
+ rptrMonitorPortUpper32Octets object, or to use the
1462
+ 64-bit counter defined by
1463
+ rptrMonitorPortHCReadableOctets instead of the
1464
+ two 32-bit counters.""",
1465
+ "reference" :
1466
+ """[IEEE 802.3 Mgt], 30.4.3.1.5, aReadableOctets.""",
1467
+ }, # column
1468
+ "rptrMonitorPortFCSErrors" : {
1469
+ "nodetype" : "column",
1470
+ "moduleName" : "SNMP-REPEATER-MIB",
1471
+ "oid" : "1.3.6.1.2.1.22.2.3.1.1.5",
1472
+ "status" : "current",
1473
+ "syntax" : {
1474
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
1475
+ },
1476
+ "access" : "readonly",
1477
+ "description" :
1478
+ """This counter is incremented by one for each frame
1479
+ received on this port with the FCSError signal
1480
+ asserted and the FramingError and CollisionEvent
1481
+ signals deasserted and whose OctetCount is greater
1482
+ than or equal to minFrameSize and less than or
1483
+ equal to maxFrameSize (Ref: 4.4.2.1, IEEE 802.3
1484
+ Std).
1485
+
1486
+ A discontinuity may occur in the value
1487
+ when the value of object
1488
+ rptrMonitorPortLastChange changes.
1489
+
1490
+ The approximate minimum time for rollover of this
1491
+ counter is 80 hours at 10Mb/s.""",
1492
+ "reference" :
1493
+ """[IEEE 802.3 Mgt], 30.4.3.1.6,
1494
+ aFrameCheckSequenceErrors.""",
1495
+ }, # column
1496
+ "rptrMonitorPortAlignmentErrors" : {
1497
+ "nodetype" : "column",
1498
+ "moduleName" : "SNMP-REPEATER-MIB",
1499
+ "oid" : "1.3.6.1.2.1.22.2.3.1.1.6",
1500
+ "status" : "current",
1501
+ "syntax" : {
1502
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
1503
+ },
1504
+ "access" : "readonly",
1505
+ "description" :
1506
+ """This counter is incremented by one for each frame
1507
+ received on this port with the FCSError and
1508
+ FramingError signals asserted and CollisionEvent
1509
+ signal deasserted and whose OctetCount is greater
1510
+ than or equal to minFrameSize and less than or
1511
+ equal to maxFrameSize (Ref: IEEE 802.3 Std,
1512
+ 4.4.2.1). If rptrMonitorPortAlignmentErrors is
1513
+ incremented then the rptrMonitorPortFCSErrors
1514
+ Counter shall not be incremented for the same
1515
+ frame.
1516
+
1517
+ A discontinuity may occur in the value
1518
+ when the value of object
1519
+ rptrMonitorPortLastChange changes.
1520
+
1521
+ The approximate minimum time for rollover of this
1522
+ counter is 80 hours at 10Mb/s.""",
1523
+ "reference" :
1524
+ """[IEEE 802.3 Mgt], 30.4.3.1.7, aAlignmentErrors.""",
1525
+ }, # column
1526
+ "rptrMonitorPortFrameTooLongs" : {
1527
+ "nodetype" : "column",
1528
+ "moduleName" : "SNMP-REPEATER-MIB",
1529
+ "oid" : "1.3.6.1.2.1.22.2.3.1.1.7",
1530
+ "status" : "current",
1531
+ "syntax" : {
1532
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
1533
+ },
1534
+ "access" : "readonly",
1535
+ "description" :
1536
+ """This counter is incremented by one for each frame
1537
+ received on this port whose OctetCount is greater
1538
+ than maxFrameSize (Ref: 4.4.2.1, IEEE 802.3 Std).
1539
+ If rptrMonitorPortFrameTooLongs is incremented
1540
+ then neither the rptrMonitorPortAlignmentErrors
1541
+ nor the rptrMonitorPortFCSErrors counter shall be
1542
+ incremented for the frame.
1543
+
1544
+ A discontinuity may occur in the value
1545
+ when the value of object
1546
+ rptrMonitorPortLastChange changes.
1547
+
1548
+ The approximate minimum time for rollover of this
1549
+ counter is 61 days in a 10Mb/s repeater.""",
1550
+ "reference" :
1551
+ """[IEEE 802.3 Mgt], 30.4.3.1.8, aFramesTooLong.""",
1552
+ }, # column
1553
+ "rptrMonitorPortShortEvents" : {
1554
+ "nodetype" : "column",
1555
+ "moduleName" : "SNMP-REPEATER-MIB",
1556
+ "oid" : "1.3.6.1.2.1.22.2.3.1.1.8",
1557
+ "status" : "current",
1558
+ "syntax" : {
1559
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
1560
+ },
1561
+ "access" : "readonly",
1562
+ "description" :
1563
+ """This counter is incremented by one for each
1564
+ CarrierEvent on this port with ActivityDuration
1565
+ less than ShortEventMaxTime. ShortEventMaxTime is
1566
+ greater than 74 bit times and less than 82 bit
1567
+ times. ShortEventMaxTime has tolerances included
1568
+ to provide for circuit losses between a
1569
+ conformance test point at the AUI and the
1570
+ measurement point within the state machine.
1571
+
1572
+ Notes:
1573
+
1574
+ ShortEvents may indicate externally
1575
+ generated noise hits which will cause the repeater
1576
+ to transmit Runts to its other ports, or propagate
1577
+ a collision (which may be late) back to the
1578
+ transmitting DTE and damaged frames to the rest of
1579
+ the network.
1580
+
1581
+ Implementors may wish to consider selecting the
1582
+ ShortEventMaxTime towards the lower end of the
1583
+ allowed tolerance range to accommodate bit losses
1584
+ suffered through physical channel devices not
1585
+ budgeted for within this standard.
1586
+
1587
+ The significance of this attribute is different
1588
+ in 10 and 100 Mb/s collision domains. Clause 9
1589
+ repeaters perform fragment extension of short
1590
+ events which would be counted as runts on the
1591
+ interconnect ports of other repeaters. Clause
1592
+ 27 repeaters do not perform fragment extension.
1593
+
1594
+ A discontinuity may occur in the value
1595
+ when the value of object
1596
+ rptrMonitorPortLastChange changes.
1597
+
1598
+ The approximate minimum time for rollover of this
1599
+ counter is 16 hours in a 10Mb/s repeater.""",
1600
+ "reference" :
1601
+ """[IEEE 802.3 Mgt], 30.4.3.1.9, aShortEvents.""",
1602
+ }, # column
1603
+ "rptrMonitorPortRunts" : {
1604
+ "nodetype" : "column",
1605
+ "moduleName" : "SNMP-REPEATER-MIB",
1606
+ "oid" : "1.3.6.1.2.1.22.2.3.1.1.9",
1607
+ "status" : "current",
1608
+ "syntax" : {
1609
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
1610
+ },
1611
+ "access" : "readonly",
1612
+ "description" :
1613
+ """This counter is incremented by one for each
1614
+ CarrierEvent on this port that meets one of the
1615
+ following two conditions. Only one test need be
1616
+ made. a) The ActivityDuration is greater than
1617
+ ShortEventMaxTime and less than ValidPacketMinTime
1618
+ and the CollisionEvent signal is deasserted. b)
1619
+ The OctetCount is less than 64, the
1620
+ ActivityDuration is greater than ShortEventMaxTime
1621
+ and the CollisionEvent signal is deasserted.
1622
+ ValidPacketMinTime is greater than or equal to 552
1623
+ bit times and less than 565 bit times.
1624
+
1625
+ An event whose length is greater than 74 bit times
1626
+ but less than 82 bit times shall increment either
1627
+ the shortEvents counter or the runts counter but
1628
+ not both. A CarrierEvent greater than or equal to
1629
+ 552 bit times but less than 565 bit times may or
1630
+ may not be counted as a runt.
1631
+
1632
+ ValidPacketMinTime has tolerances included to
1633
+ provide for circuit losses between a conformance
1634
+ test point at the AUI and the measurement point
1635
+ within the state machine.
1636
+
1637
+ Runts usually indicate collision fragments, a
1638
+ normal network event. In certain situations
1639
+ associated with large diameter networks a
1640
+ percentage of collision fragments may exceed
1641
+ ValidPacketMinTime.
1642
+ A discontinuity may occur in the value
1643
+ when the value of object
1644
+ rptrMonitorPortLastChange changes.
1645
+
1646
+ The approximate minimum time for rollover of this
1647
+ counter is 16 hours in a 10Mb/s repeater.""",
1648
+ "reference" :
1649
+ """[IEEE 802.3 Mgt], 30.4.3.1.10, aRunts.""",
1650
+ }, # column
1651
+ "rptrMonitorPortCollisions" : {
1652
+ "nodetype" : "column",
1653
+ "moduleName" : "SNMP-REPEATER-MIB",
1654
+ "oid" : "1.3.6.1.2.1.22.2.3.1.1.10",
1655
+ "status" : "current",
1656
+ "syntax" : {
1657
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
1658
+ },
1659
+ "access" : "readonly",
1660
+ "description" :
1661
+ """For a clause 9 repeater, this counter is
1662
+ incremented by one for any CarrierEvent signal
1663
+ on any port for which the CollisionEvent signal
1664
+ on this port is asserted. For a clause 27
1665
+ repeater port the counter increments on entering
1666
+ the Collision Count Increment state of the
1667
+ partition state diagram (fig 27-8 of
1668
+ [IEEE 802.3 Std]).
1669
+
1670
+ A discontinuity may occur in the value
1671
+ when the value of object
1672
+ rptrMonitorPortLastChange changes.
1673
+
1674
+ The approximate minimum time for rollover of this
1675
+ counter is 16 hours in a 10Mb/s repeater.""",
1676
+ "reference" :
1677
+ """[IEEE 802.3 Mgt], 30.4.3.1.11, aCollisions.""",
1678
+ }, # column
1679
+ "rptrMonitorPortLateEvents" : {
1680
+ "nodetype" : "column",
1681
+ "moduleName" : "SNMP-REPEATER-MIB",
1682
+ "oid" : "1.3.6.1.2.1.22.2.3.1.1.11",
1683
+ "status" : "current",
1684
+ "syntax" : {
1685
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
1686
+ },
1687
+ "access" : "readonly",
1688
+ "description" :
1689
+ """For a clause 9 repeater port, this counter is
1690
+ incremented by one for each CarrierEvent
1691
+ on this port in which the CollIn(X)
1692
+ variable transitions to the value SQE (Ref:
1693
+ 9.6.6.2, IEEE 802.3 Std) while the
1694
+ ActivityDuration is greater than the
1695
+ LateEventThreshold. For a clause 27 repeater
1696
+ port, this counter is incremented by one on
1697
+ entering the Collision Count Increment state
1698
+ of the partition state diagram (fig 27-8)
1699
+ while the ActivityDuration is greater than
1700
+ the LateEvent- Threshold. Such a CarrierEvent
1701
+ is counted twice, as both a collision and as a
1702
+ lateEvent.
1703
+
1704
+ The LateEventThreshold is greater than 480 bit
1705
+ times and less than 565 bit times.
1706
+ LateEventThreshold has tolerances included to
1707
+ permit an implementation to build a single
1708
+ threshold to serve as both the LateEventThreshold
1709
+ and ValidPacketMinTime threshold.
1710
+
1711
+ A discontinuity may occur in the value
1712
+ when the value of object
1713
+ rptrMonitorPortLastChange changes.
1714
+
1715
+ The approximate minimum time for rollover of this
1716
+ counter is 81 hours in a 10Mb/s repeater.""",
1717
+ "reference" :
1718
+ """[IEEE 802.3 Mgt], 30.4.3.1.12, aLateEvents.""",
1719
+ }, # column
1720
+ "rptrMonitorPortVeryLongEvents" : {
1721
+ "nodetype" : "column",
1722
+ "moduleName" : "SNMP-REPEATER-MIB",
1723
+ "oid" : "1.3.6.1.2.1.22.2.3.1.1.12",
1724
+ "status" : "current",
1725
+ "syntax" : {
1726
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
1727
+ },
1728
+ "access" : "readonly",
1729
+ "description" :
1730
+ """For a clause 9 repeater port, this counter
1731
+ is incremented by one for each CarrierEvent
1732
+ whose ActivityDuration is greater than the
1733
+ MAU Jabber Lockup Protection timer TW3
1734
+ (Ref: 9.6.1 & 9.6.5, IEEE 802.3 Std).
1735
+
1736
+ For a clause 27 repeater port, this counter
1737
+ is incremented by one on entry to the
1738
+ Rx Jabber state of the receiver timer state
1739
+ diagram (fig 27-7). Other counters may
1740
+ be incremented as appropriate.
1741
+
1742
+ A discontinuity may occur in the value
1743
+ when the value of object
1744
+ rptrMonitorPortLastChange changes.""",
1745
+ "reference" :
1746
+ """[IEEE 802.3 Mgt], 30.4.3.1.13, aVeryLongEvents.""",
1747
+ }, # column
1748
+ "rptrMonitorPortDataRateMismatches" : {
1749
+ "nodetype" : "column",
1750
+ "moduleName" : "SNMP-REPEATER-MIB",
1751
+ "oid" : "1.3.6.1.2.1.22.2.3.1.1.13",
1752
+ "status" : "current",
1753
+ "syntax" : {
1754
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
1755
+ },
1756
+ "access" : "readonly",
1757
+ "description" :
1758
+ """This counter is incremented by one for each
1759
+ frame received by this port that meets all
1760
+ of the conditions required by only one of the
1761
+ following two measurement methods:
1762
+
1763
+ Measurement method A: 1) The CollisionEvent
1764
+ signal is not asserted (10Mb/s operation) or
1765
+ the Collision Count Increment state of the
1766
+ partition state diagram (fig 27-8 of
1767
+ [IEEE 802.3 Std]) has not been entered
1768
+ (100Mb/s operation). 2) The ActivityDuration
1769
+ is greater than ValidPacketMinTime. 3) The
1770
+ frequency (data rate) is detectably mismatched
1771
+ from the local transmit frequency.
1772
+
1773
+ Measurement method B: 1) The CollisionEvent
1774
+ signal is not asserted (10Mb/s operation)
1775
+ or the Collision Count Increment state of the
1776
+ partition state diagram (fig 27-8 of
1777
+ [IEEE 802.3 Std]) has not been entered
1778
+ (100Mb/s operation). 2) The OctetCount is
1779
+ greater than 63. 3) The frequency (data
1780
+ rate) is detectably mismatched from the local
1781
+ transmit frequency. The exact degree of
1782
+ mismatch is vendor specific and is to be
1783
+ defined by the vendor for conformance testing.
1784
+
1785
+ When this event occurs, other counters whose
1786
+ increment conditions were satisfied may or may not
1787
+ also be incremented, at the implementor's
1788
+ discretion. Whether or not the repeater was able
1789
+ to maintain data integrity is beyond the scope of
1790
+ this standard.
1791
+
1792
+ A discontinuity may occur in the value
1793
+ when the value of object
1794
+ rptrMonitorPortLastChange changes.""",
1795
+ "reference" :
1796
+ """[IEEE 802.3 Mgt], 30.4.3.1.14, aDataRateMismatches.""",
1797
+ }, # column
1798
+ "rptrMonitorPortAutoPartitions" : {
1799
+ "nodetype" : "column",
1800
+ "moduleName" : "SNMP-REPEATER-MIB",
1801
+ "oid" : "1.3.6.1.2.1.22.2.3.1.1.14",
1802
+ "status" : "current",
1803
+ "syntax" : {
1804
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
1805
+ },
1806
+ "access" : "readonly",
1807
+ "description" :
1808
+ """This counter is incremented by one for
1809
+ each time the repeater has automatically
1810
+ partitioned this port.
1811
+
1812
+ The conditions that cause a clause 9
1813
+ repeater port to partition are specified in
1814
+ the partition state diagram in clause 9 of
1815
+ [IEEE 802.3 Std]. They are not differentiated
1816
+ here. A clause 27 repeater port partitions
1817
+ on entry to the Partition Wait state of the
1818
+ partition state diagram (fig 27-8 in
1819
+ [IEEE 802.3 Std]).
1820
+
1821
+ A discontinuity may occur in the value
1822
+ when the value of object
1823
+ rptrMonitorPortLastChange changes.""",
1824
+ "reference" :
1825
+ """[IEEE 802.3 Mgt], 30.4.3.1.15, aAutoPartitions.""",
1826
+ }, # column
1827
+ "rptrMonitorPortTotalErrors" : {
1828
+ "nodetype" : "column",
1829
+ "moduleName" : "SNMP-REPEATER-MIB",
1830
+ "oid" : "1.3.6.1.2.1.22.2.3.1.1.15",
1831
+ "status" : "current",
1832
+ "syntax" : {
1833
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
1834
+ },
1835
+ "access" : "readonly",
1836
+ "description" :
1837
+ """The total number of errors which have occurred on
1838
+ this port. This counter is the summation of the
1839
+ values of other error counters (for the same
1840
+ port), namely:
1841
+
1842
+ rptrMonitorPortFCSErrors,
1843
+ rptrMonitorPortAlignmentErrors,
1844
+ rptrMonitorPortFrameTooLongs,
1845
+ rptrMonitorPortShortEvents,
1846
+ rptrMonitorPortLateEvents,
1847
+ rptrMonitorPortVeryLongEvents,
1848
+ rptrMonitorPortDataRateMismatches, and
1849
+ rptrMonitorPortSymbolErrors.
1850
+
1851
+ This counter is redundant in the sense that it is
1852
+ the summation of information already available
1853
+ through other objects. However, it is included
1854
+ specifically because the regular retrieval of this
1855
+ object as a means of tracking the health of a port
1856
+ provides a considerable optimization of network
1857
+ management traffic over the otherwise necessary
1858
+ retrieval of the summed counters.
1859
+
1860
+ Note that rptrMonitorPortRunts is not included
1861
+ in this total; this is because runts usually
1862
+ indicate collision fragments, a normal network
1863
+ event.
1864
+
1865
+ A discontinuity may occur in the value
1866
+ when the value of object
1867
+ rptrMonitorPortLastChange changes.""",
1868
+ }, # column
1869
+ "rptrMonitorPortLastChange" : {
1870
+ "nodetype" : "column",
1871
+ "moduleName" : "SNMP-REPEATER-MIB",
1872
+ "oid" : "1.3.6.1.2.1.22.2.3.1.1.16",
1873
+ "status" : "current",
1874
+ "syntax" : {
1875
+ "type" : { "module" :"SNMPv2-TC", "name" : "TimeStamp"},
1876
+ },
1877
+ "access" : "readonly",
1878
+ "description" :
1879
+ """The value of sysUpTime when the last of
1880
+ the following occurred:
1881
+ 1) the agent cold- or warm-started;
1882
+ 2) the row for the port was created
1883
+ (such as when a device or module was added
1884
+ to the system); or
1885
+ 3) any condition that would cause one of
1886
+ the counters for the row to experience
1887
+ a discontinuity.""",
1888
+ }, # column
1889
+ "rptrMonitor100PortTable" : {
1890
+ "nodetype" : "table",
1891
+ "moduleName" : "SNMP-REPEATER-MIB",
1892
+ "oid" : "1.3.6.1.2.1.22.2.3.2",
1893
+ "status" : "current",
1894
+ "description" :
1895
+ """Table of additional performance and error
1896
+ statistics for 100Mb/s ports, above and
1897
+ beyond those parameters that apply to both
1898
+ 10 and 100Mbps ports. Entries exist only for
1899
+ ports attached to 100Mbps repeaters.
1900
+
1901
+ The columnar object rptrMonitorPortLastChange
1902
+ is used to indicate possible discontinuities
1903
+ of counter type columnar objects in this table.""",
1904
+ }, # table
1905
+ "rptrMonitor100PortEntry" : {
1906
+ "nodetype" : "row",
1907
+ "moduleName" : "SNMP-REPEATER-MIB",
1908
+ "oid" : "1.3.6.1.2.1.22.2.3.2.1",
1909
+ "status" : "current",
1910
+ "linkage" : [
1911
+ "rptrMonitorPortGroupIndex",
1912
+ "rptrMonitorPortIndex",
1913
+ ],
1914
+ "description" :
1915
+ """An entry in the table, containing performance
1916
+ and error statistics for a single 100Mb/s port.""",
1917
+ }, # row
1918
+ "rptrMonitorPortIsolates" : {
1919
+ "nodetype" : "column",
1920
+ "moduleName" : "SNMP-REPEATER-MIB",
1921
+ "oid" : "1.3.6.1.2.1.22.2.3.2.1.1",
1922
+ "status" : "current",
1923
+ "syntax" : {
1924
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
1925
+ },
1926
+ "access" : "readonly",
1927
+ "description" :
1928
+ """This counter is incremented by one each time that
1929
+ the repeater port automatically isolates as a
1930
+ consequence of false carrier events. The conditions
1931
+ which cause a port to automatically isolate are
1932
+ defined by the transition from the False Carrier
1933
+ state to the Link Unstable state of the carrier
1934
+ integrity state diagram (figure 27-9)
1935
+ [IEEE 802.3 Standard].
1936
+
1937
+ Note: Isolates do not affect the value of
1938
+ the PortOperStatus object.
1939
+
1940
+ A discontinuity may occur in the value
1941
+ when the value of object
1942
+ rptrMonitorPortLastChange changes.""",
1943
+ "reference" :
1944
+ """[IEEE 802.3 Mgt], 30.4.3.1.16, aIsolates.""",
1945
+ }, # column
1946
+ "rptrMonitorPortSymbolErrors" : {
1947
+ "nodetype" : "column",
1948
+ "moduleName" : "SNMP-REPEATER-MIB",
1949
+ "oid" : "1.3.6.1.2.1.22.2.3.2.1.2",
1950
+ "status" : "current",
1951
+ "syntax" : {
1952
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
1953
+ },
1954
+ "access" : "readonly",
1955
+ "description" :
1956
+ """This counter is incremented by one each time when
1957
+ valid length packet was received at the port and
1958
+ there was at least one occurrence of an invalid
1959
+ data symbol. This can increment only once per valid
1960
+ carrier event. A collision presence at any port of
1961
+ the repeater containing port N, will not cause this
1962
+ attribute to increment.
1963
+
1964
+ A discontinuity may occur in the value
1965
+ when the value of object
1966
+ rptrMonitorPortLastChange changes.
1967
+
1968
+ The approximate minimum time for rollover of this
1969
+ counter is 7.4 hours at 100Mb/s.""",
1970
+ "reference" :
1971
+ """[IEEE 802.3 Mgt], 30.4.3.1.17,
1972
+ aSymbolErrorDuringPacket.""",
1973
+ }, # column
1974
+ "rptrMonitorPortUpper32Octets" : {
1975
+ "nodetype" : "column",
1976
+ "moduleName" : "SNMP-REPEATER-MIB",
1977
+ "oid" : "1.3.6.1.2.1.22.2.3.2.1.3",
1978
+ "status" : "current",
1979
+ "syntax" : {
1980
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
1981
+ },
1982
+ "access" : "readonly",
1983
+ "description" :
1984
+ """This object is the number of octets contained in
1985
+ valid frames that have been received on this port,
1986
+ modulo 2**32. That is, it contains the upper 32
1987
+ bits of a 64-bit octets counter, of which the
1988
+ lower 32 bits are contained in the
1989
+ rptrMonitorPortReadableOctets object.
1990
+
1991
+ This two-counter mechanism is provided for those
1992
+ network management protocols that do not support
1993
+ 64-bit counters (e.g. SNMP V1) and are used to
1994
+ manage a repeater type of 100Mb/s.
1995
+
1996
+ Conformance clauses for this MIB are defined such
1997
+ that implementation of this object is not required
1998
+ in a system which does not support 100Mb/s.
1999
+ However, systems with mixed 10 and 100Mb/s ports
2000
+ may implement this object across all ports,
2001
+ including 10Mb/s. If this object is implemented,
2002
+ it must be according to the definition in the first
2003
+ paragraph of this description; that is, the value
2004
+ of this object MUST be a valid count.
2005
+
2006
+ A discontinuity may occur in the value
2007
+ when the value of object
2008
+ rptrMonitorPortLastChange changes.""",
2009
+ }, # column
2010
+ "rptrMonitorPortHCReadableOctets" : {
2011
+ "nodetype" : "column",
2012
+ "moduleName" : "SNMP-REPEATER-MIB",
2013
+ "oid" : "1.3.6.1.2.1.22.2.3.2.1.4",
2014
+ "status" : "current",
2015
+ "syntax" : {
2016
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter64"},
2017
+ },
2018
+ "access" : "readonly",
2019
+ "description" :
2020
+ """This object is the number of octets contained in
2021
+ valid frames that have been received on this port.
2022
+ This counter is incremented by OctetCount for each
2023
+ frame received on this port which has been
2024
+ determined to be a readable frame (i.e., including
2025
+ FCS octets but excluding framing bits and dribble
2026
+ bits).
2027
+
2028
+ This statistic provides an indicator of the total
2029
+ data transferred.
2030
+
2031
+ This counter is a 64-bit version of rptrMonitor-
2032
+ PortReadableOctets. It should be used by network
2033
+ management protocols which suppport 64-bit counters
2034
+ (e.g. SNMPv2).
2035
+
2036
+ Conformance clauses for this MIB are defined such
2037
+ that implementation of this object is not required
2038
+ in a system which does not support 100Mb/s.
2039
+ However, systems with mixed 10 and 100Mb/s ports
2040
+ may implement this object across all ports,
2041
+ including 10Mb/s. If this object is implemented,
2042
+ it must be according to the definition in the first
2043
+ paragraph of this description; that is, the value
2044
+ of this object MUST be a valid count.
2045
+
2046
+ A discontinuity may occur in the value
2047
+ when the value of object
2048
+ rptrMonitorPortLastChange changes.""",
2049
+ "reference" :
2050
+ """[IEEE 802.3 Mgt], 30.4.3.1.5, aReadableOctets.""",
2051
+ }, # column
2052
+ "rptrMonitorAllRptrInfo" : {
2053
+ "nodetype" : "node",
2054
+ "moduleName" : "SNMP-REPEATER-MIB",
2055
+ "oid" : "1.3.6.1.2.1.22.2.4",
2056
+ }, # node
2057
+ "rptrMonTable" : {
2058
+ "nodetype" : "table",
2059
+ "moduleName" : "SNMP-REPEATER-MIB",
2060
+ "oid" : "1.3.6.1.2.1.22.2.4.1",
2061
+ "status" : "current",
2062
+ "description" :
2063
+ """A table of information about each
2064
+ non-trivial repeater. The number of entries
2065
+ in this table is the same as the number of
2066
+ entries in the rptrInfoTable.
2067
+
2068
+ The columnar object rptrInfoLastChange is
2069
+ used to indicate possible discontinuities of
2070
+ counter type columnar objects in this table.""",
2071
+ }, # table
2072
+ "rptrMonEntry" : {
2073
+ "nodetype" : "row",
2074
+ "moduleName" : "SNMP-REPEATER-MIB",
2075
+ "oid" : "1.3.6.1.2.1.22.2.4.1.1",
2076
+ "status" : "current",
2077
+ "linkage" : [
2078
+ "rptrInfoId",
2079
+ ],
2080
+ "description" :
2081
+ """An entry in the table, containing information
2082
+ about a single non-trivial repeater.""",
2083
+ }, # row
2084
+ "rptrMonTxCollisions" : {
2085
+ "nodetype" : "column",
2086
+ "moduleName" : "SNMP-REPEATER-MIB",
2087
+ "oid" : "1.3.6.1.2.1.22.2.4.1.1.1",
2088
+ "status" : "current",
2089
+ "syntax" : {
2090
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
2091
+ },
2092
+ "access" : "readonly",
2093
+ "description" :
2094
+ """For a clause 9 (10Mb/s) repeater, this counter
2095
+ is incremented every time the repeater state
2096
+ machine enters the TRANSMIT COLLISION state
2097
+ from any state other than ONE PORT LEFT
2098
+ (Ref: Fig 9-2 [IEEE 802.3 Std]).
2099
+
2100
+ For a clause 27 repeater, this counter is
2101
+ incremented every time the repeater core state
2102
+ diagram enters the Jam state as a result of
2103
+ Activity(ALL) > 1 (fig 27-2 [IEEE 802.3 Std]).
2104
+
2105
+ The approximate minimum time for rollover of this
2106
+ counter is 16 hours in a 10Mb/s repeater and 1.6
2107
+ hours in a 100Mb/s repeater.""",
2108
+ "reference" :
2109
+ """[IEEE 802.3 Mgt], 30.4.1.1.8, aTransmitCollisions""",
2110
+ }, # column
2111
+ "rptrMonTotalFrames" : {
2112
+ "nodetype" : "column",
2113
+ "moduleName" : "SNMP-REPEATER-MIB",
2114
+ "oid" : "1.3.6.1.2.1.22.2.4.1.1.3",
2115
+ "status" : "current",
2116
+ "syntax" : {
2117
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
2118
+ },
2119
+ "access" : "readonly",
2120
+ "description" :
2121
+ """The number of frames of valid frame length
2122
+ that have been received on the ports in this repeater
2123
+ and for which the FCSError and CollisionEvent
2124
+ signals were not asserted. If an implementation
2125
+ can not obtain a count of frames as seen by
2126
+ the repeater itself, this counter may be
2127
+ implemented as the summation of the values of the
2128
+ rptrMonitorPortReadableFrames counters for all of
2129
+ the ports in the repeater.
2130
+
2131
+ This statistic provides one of the parameters
2132
+ necessary for obtaining the packet error rate.
2133
+ The approximate minimum time for rollover of this
2134
+ counter is 80 hours in a 10Mb/s repeater.""",
2135
+ }, # column
2136
+ "rptrMonTotalErrors" : {
2137
+ "nodetype" : "column",
2138
+ "moduleName" : "SNMP-REPEATER-MIB",
2139
+ "oid" : "1.3.6.1.2.1.22.2.4.1.1.4",
2140
+ "status" : "current",
2141
+ "syntax" : {
2142
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
2143
+ },
2144
+ "access" : "readonly",
2145
+ "description" :
2146
+ """The total number of errors which have occurred on
2147
+ all of the ports in this repeater. The errors
2148
+ included in this count are the same as those listed
2149
+ for the rptrMonitorPortTotalErrors counter. If an
2150
+ implementation can not obtain a count of these
2151
+ errors as seen by the repeater itself, this counter
2152
+ may be implemented as the summation of the values of
2153
+ the rptrMonitorPortTotalErrors counters for all of
2154
+ the ports in the repeater.""",
2155
+ }, # column
2156
+ "rptrMonTotalOctets" : {
2157
+ "nodetype" : "column",
2158
+ "moduleName" : "SNMP-REPEATER-MIB",
2159
+ "oid" : "1.3.6.1.2.1.22.2.4.1.1.5",
2160
+ "status" : "current",
2161
+ "syntax" : {
2162
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
2163
+ },
2164
+ "access" : "readonly",
2165
+ "description" :
2166
+ """The total number of octets contained in the valid
2167
+ frames that have been received on the ports in
2168
+ this group. If an implementation can not obtain
2169
+ a count of octets as seen by the repeater itself,
2170
+ this counter may be the summation of the
2171
+ values of the rptrMonitorPortReadableOctets
2172
+ counters for all of the ports in the group.
2173
+
2174
+ This statistic provides an indicator of the total
2175
+ data transferred. The approximate minimum time
2176
+ for rollover of this counter in a 10Mb/s repeater
2177
+ is 58 minutes divided by the number of ports in
2178
+ the repeater.
2179
+
2180
+ For 100Mb/s repeaters processing traffic at a
2181
+ maximum rate, this counter can roll over in less
2182
+ than 6 minutes divided by the number of ports in
2183
+ the repeater. Since that amount of time could
2184
+ be less than a management station's poll cycle
2185
+ time, in order to avoid a loss of information a
2186
+ management station is advised to also poll the
2187
+ rptrMonUpper32TotalOctets object, or to use the
2188
+ 64-bit counter defined by rptrMonHCTotalOctets
2189
+ instead of the two 32-bit counters.""",
2190
+ }, # column
2191
+ "rptrMon100Table" : {
2192
+ "nodetype" : "table",
2193
+ "moduleName" : "SNMP-REPEATER-MIB",
2194
+ "oid" : "1.3.6.1.2.1.22.2.4.2",
2195
+ "status" : "current",
2196
+ "description" :
2197
+ """A table of additional information about each
2198
+ 100Mb/s repeater, augmenting the entries in
2199
+ the rptrMonTable. Entries exist in this table
2200
+ only for 100Mb/s repeaters.
2201
+
2202
+ The columnar object rptrInfoLastChange is
2203
+ used to indicate possible discontinuities of
2204
+ counter type columnar objects in this table.""",
2205
+ }, # table
2206
+ "rptrMon100Entry" : {
2207
+ "nodetype" : "row",
2208
+ "moduleName" : "SNMP-REPEATER-MIB",
2209
+ "oid" : "1.3.6.1.2.1.22.2.4.2.1",
2210
+ "status" : "current",
2211
+ "linkage" : [
2212
+ "rptrInfoId",
2213
+ ],
2214
+ "description" :
2215
+ """An entry in the table, containing information
2216
+ about a single 100Mbps repeater.""",
2217
+ }, # row
2218
+ "rptrMonUpper32TotalOctets" : {
2219
+ "nodetype" : "column",
2220
+ "moduleName" : "SNMP-REPEATER-MIB",
2221
+ "oid" : "1.3.6.1.2.1.22.2.4.2.1.1",
2222
+ "status" : "current",
2223
+ "syntax" : {
2224
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
2225
+ },
2226
+ "access" : "readonly",
2227
+ "description" :
2228
+ """The total number of octets contained in the valid
2229
+ frames that have been received on the ports in
2230
+ this repeater, modulo 2**32. That is, it contains
2231
+ the upper 32 bits of a 64-bit counter, of which
2232
+ the lower 32 bits are contained in the
2233
+ rptrMonTotalOctets object. If an implementation
2234
+ can not obtain a count of octets as seen
2235
+ by the repeater itself, the 64-bit value
2236
+ may be the summation of the values of the
2237
+ rptrMonitorPortReadableOctets counters combined
2238
+ with the corresponding rptrMonitorPortUpper32Octets
2239
+ counters for all of the ports in the repeater.
2240
+
2241
+ This statistic provides an indicator of the total
2242
+ data transferred within the repeater.
2243
+
2244
+ This two-counter mechanism is provided for those
2245
+ network management protocols that do not support
2246
+ 64-bit counters (e.g. SNMP V1) and are used to
2247
+ manage a repeater type of 100Mb/s.
2248
+
2249
+ Conformance clauses for this MIB are defined such
2250
+ that implementation of this object is not required
2251
+ in a system which does not support 100Mb/s.
2252
+ However, systems with mixed 10 and 100Mb/s ports
2253
+ may implement this object across all ports,
2254
+ including 10Mb/s. If this object is implemented,
2255
+ it must be according to the definition in the first
2256
+ paragraph of this description; that is, the value
2257
+ of this object MUST be a valid count.""",
2258
+ }, # column
2259
+ "rptrMonHCTotalOctets" : {
2260
+ "nodetype" : "column",
2261
+ "moduleName" : "SNMP-REPEATER-MIB",
2262
+ "oid" : "1.3.6.1.2.1.22.2.4.2.1.2",
2263
+ "status" : "current",
2264
+ "syntax" : {
2265
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter64"},
2266
+ },
2267
+ "access" : "readonly",
2268
+ "description" :
2269
+ """The total number of octets contained in the valid
2270
+ frames that have been received on the ports in
2271
+ this group. If a implementation can not obtain
2272
+ a count of octets as seen by the repeater itself,
2273
+ this counter may be the summation of the
2274
+ values of the rptrMonitorPortReadableOctets
2275
+ counters for all of the ports in the group.
2276
+
2277
+ This statistic provides an indicator of the total
2278
+ data transferred.
2279
+
2280
+ This counter is a 64-bit (high-capacity) version
2281
+ of rptrMonUpper32TotalOctets and rptrMonTotalOctets.
2282
+ It should be used by network management protocols
2283
+ which support 64-bit counters (e.g. SNMPv2).
2284
+
2285
+ Conformance clauses for this MIB are defined such
2286
+ that implementation of this object is not required
2287
+ in a system which does not support 100Mb/s.
2288
+ However, systems with mixed 10 and 100Mb/s ports
2289
+ may implement this object across all ports,
2290
+ including 10Mb/s. If this object is implemented,
2291
+ it must be according to the definition in the first
2292
+ paragraph of this description; that is, the value
2293
+ of this object MUST be a valid count.""",
2294
+ }, # column
2295
+ "rptrAddrTrackPackage" : {
2296
+ "nodetype" : "node",
2297
+ "moduleName" : "SNMP-REPEATER-MIB",
2298
+ "oid" : "1.3.6.1.2.1.22.3",
2299
+ }, # node
2300
+ "rptrAddrTrackRptrInfo" : {
2301
+ "nodetype" : "node",
2302
+ "moduleName" : "SNMP-REPEATER-MIB",
2303
+ "oid" : "1.3.6.1.2.1.22.3.1",
2304
+ }, # node
2305
+ "rptrAddrSearchTable" : {
2306
+ "nodetype" : "table",
2307
+ "moduleName" : "SNMP-REPEATER-MIB",
2308
+ "oid" : "1.3.6.1.2.1.22.3.1.1",
2309
+ "status" : "current",
2310
+ "description" :
2311
+ """This table contains one entry per repeater in the
2312
+ system. It defines objects which allow a network
2313
+ management application to instruct an agent to watch
2314
+ for a given MAC address and report which port it
2315
+ was seen on. Only one address search can be in
2316
+ progress on each repeater at any one time. Before
2317
+ starting an address search, a management application
2318
+ should obtain 'ownership' of the entry in
2319
+ rptrAddrSearchTable for the repeater that is to
2320
+ perform the search. This is accomplished with the
2321
+ rptrAddrSearchLock and rptrAddrSearchStatus as
2322
+ follows:
2323
+
2324
+ try_again:
2325
+ get(rptrAddrSearchLock, rptrAddrSearchStatus)
2326
+ while (rptrAddrSearchStatus != notInUse)
2327
+ {
2328
+ /* Loop waiting for objects to be available*/
2329
+ short delay
2330
+ get(rptrAddrSearchLock, rptrAddrSearchStatus)
2331
+ }
2332
+
2333
+ /* Try to claim map objects */
2334
+ lock_value = rptrAddrSearchLock
2335
+ if ( set(rptrAddrSearchLock = lock_value,
2336
+ rptrAddrSearchStatus = inUse,
2337
+ rptrAddrSearchOwner = 'my-IP-address)
2338
+ == FAILURE)
2339
+ /* Another manager got the lock */
2340
+ goto try_again
2341
+
2342
+ /* I have the lock */
2343
+ set (rptrAddrSearchAddress = <search target>)
2344
+
2345
+ wait for rptrAddrSearchState to change from none
2346
+
2347
+ if (rptrAddrSearchState == single)
2348
+ get (rptrAddrSearchGroup, rptrAddrSearchPort)
2349
+ /* release the lock, making sure not to overwrite
2350
+ anyone else's lock */
2351
+ set (rptrAddrSearchLock = lock_value+1,
2352
+ rptrAddrSearchStatus = notInUse,
2353
+ rptrAddrSearchOwner = '')
2354
+
2355
+ A management station first retrieves the values of
2356
+ the appropriate instances of the rptrAddrSearchLock
2357
+ and rptrAddrSearchStatus objects, periodically
2358
+ repeating the retrieval if necessary, until the value
2359
+ of rptrAddrSearchStatus is 'notInUse'. The
2360
+ management station then tries to set the same
2361
+ instance of the rptrAddrSearchLock object to the
2362
+ value it just retrieved, the same instance of the
2363
+ rptrAddrSearchStatus object to 'inUse', and the
2364
+ corresponding instance of rptrAddrSearchOwner to a
2365
+ value indicating itself. If the set operation
2366
+ succeeds, then the management station has obtained
2367
+ ownership of the rptrAddrSearchEntry, and the value
2368
+ of rptrAddrSearchLock is incremented by the agent (as
2369
+ per the semantics of TestAndIncr). Failure of the
2370
+ set operation indicates that some other manager has
2371
+ obtained ownership of the rptrAddrSearchEntry.
2372
+
2373
+ Once ownership is obtained, the management station
2374
+ can proceed with the search operation. Note that the
2375
+ agent will reset rptrAddrSearchStatus to 'notInUse'
2376
+ if it has been in the 'inUse' state for an abnormally
2377
+ long period of time, to prevent a misbehaving manager
2378
+ from permanently locking the entry. It is suggested
2379
+ that this timeout period be between one and five
2380
+ minutes.
2381
+
2382
+ When the management station has completed its search
2383
+ operation, it should free the entry by setting
2384
+ the instance of the rptrAddrSearchLock object to the
2385
+ previous value + 1, the instance of the
2386
+ rptrAddrSearchStatus to 'notInUse', and the instance
2387
+ of rptrAddrSearchOwner to a zero length string. This
2388
+ is done to prevent overwriting another station's
2389
+ lock.""",
2390
+ }, # table
2391
+ "rptrAddrSearchEntry" : {
2392
+ "nodetype" : "row",
2393
+ "moduleName" : "SNMP-REPEATER-MIB",
2394
+ "oid" : "1.3.6.1.2.1.22.3.1.1.1",
2395
+ "status" : "current",
2396
+ "linkage" : [
2397
+ "rptrInfoId",
2398
+ ],
2399
+ "description" :
2400
+ """An entry containing objects for invoking an address
2401
+ search on a repeater.""",
2402
+ }, # row
2403
+ "rptrAddrSearchLock" : {
2404
+ "nodetype" : "column",
2405
+ "moduleName" : "SNMP-REPEATER-MIB",
2406
+ "oid" : "1.3.6.1.2.1.22.3.1.1.1.1",
2407
+ "status" : "current",
2408
+ "syntax" : {
2409
+ "type" : { "module" :"SNMPv2-TC", "name" : "TestAndIncr"},
2410
+ },
2411
+ "access" : "readwrite",
2412
+ "description" :
2413
+ """This object is used by a management station as an
2414
+ advisory lock for this rptrAddrSearchEntry.""",
2415
+ }, # column
2416
+ "rptrAddrSearchStatus" : {
2417
+ "nodetype" : "column",
2418
+ "moduleName" : "SNMP-REPEATER-MIB",
2419
+ "oid" : "1.3.6.1.2.1.22.3.1.1.1.2",
2420
+ "status" : "current",
2421
+ "syntax" : {
2422
+ "type" : {
2423
+ "basetype" : "Enumeration",
2424
+ "notInUse" : {
2425
+ "nodetype" : "namednumber",
2426
+ "number" : "1"
2427
+ },
2428
+ "inUse" : {
2429
+ "nodetype" : "namednumber",
2430
+ "number" : "2"
2431
+ },
2432
+ },
2433
+ },
2434
+ "access" : "readwrite",
2435
+ "description" :
2436
+ """This object is used to indicate that some management
2437
+ station is currently using this rptrAddrSearchEntry.
2438
+ Cooperating managers should set this object to
2439
+ 'notInUse' when they are finished using this entry.
2440
+ The agent will automatically set the value of this
2441
+ object to 'notInUse' if it has been set to 'inUse'
2442
+ for an unusually long period of time.""",
2443
+ }, # column
2444
+ "rptrAddrSearchAddress" : {
2445
+ "nodetype" : "column",
2446
+ "moduleName" : "SNMP-REPEATER-MIB",
2447
+ "oid" : "1.3.6.1.2.1.22.3.1.1.1.3",
2448
+ "status" : "current",
2449
+ "syntax" : {
2450
+ "type" : { "module" :"SNMPv2-TC", "name" : "MacAddress"},
2451
+ },
2452
+ "access" : "readwrite",
2453
+ "description" :
2454
+ """This object is used to search for a specified MAC
2455
+ address. When this object is set, an address search
2456
+ begins. This automatically sets the corresponding
2457
+ instance of the rptrAddrSearchState object to 'none'
2458
+ and the corresponding instances of the
2459
+ rptrAddrSearchGroup and rptrAddrSearchPort objects to
2460
+ 0.
2461
+
2462
+ When a valid frame is received by this repeater with
2463
+ a source MAC address which matches the current value
2464
+ of rptrAddrSearchAddress, the agent will update the
2465
+ corresponding instances of rptrAddrSearchState,
2466
+ rptrAddrSearchGroup and rptrAddrSearchPort to reflect
2467
+ the current status of the search, and the group and
2468
+ port on which the frame was seen.""",
2469
+ }, # column
2470
+ "rptrAddrSearchState" : {
2471
+ "nodetype" : "column",
2472
+ "moduleName" : "SNMP-REPEATER-MIB",
2473
+ "oid" : "1.3.6.1.2.1.22.3.1.1.1.4",
2474
+ "status" : "current",
2475
+ "syntax" : {
2476
+ "type" : {
2477
+ "basetype" : "Enumeration",
2478
+ "none" : {
2479
+ "nodetype" : "namednumber",
2480
+ "number" : "1"
2481
+ },
2482
+ "single" : {
2483
+ "nodetype" : "namednumber",
2484
+ "number" : "2"
2485
+ },
2486
+ "multiple" : {
2487
+ "nodetype" : "namednumber",
2488
+ "number" : "3"
2489
+ },
2490
+ },
2491
+ },
2492
+ "access" : "readonly",
2493
+ "description" :
2494
+ """The current state of the MAC address search on this
2495
+ repeater. This object is initialized to 'none' when
2496
+ the corresponding instance of rptrAddrSearchAddress
2497
+ is set. If the agent detects the address on exactly
2498
+ one port, it will set this object to 'single', and
2499
+ set the corresponding instances of
2500
+ rptrAddrSearchGroup and rptrAddrSearchPort to reflect
2501
+ the group and port on which the address was heard.
2502
+ If the agent detects the address on more than one
2503
+ port, it will set this object to 'multiple'.""",
2504
+ }, # column
2505
+ "rptrAddrSearchGroup" : {
2506
+ "nodetype" : "column",
2507
+ "moduleName" : "SNMP-REPEATER-MIB",
2508
+ "oid" : "1.3.6.1.2.1.22.3.1.1.1.5",
2509
+ "status" : "current",
2510
+ "syntax" : {
2511
+ "type" : {
2512
+ "basetype" : "Integer32",
2513
+ "ranges" : [
2514
+ {
2515
+ "min" : "0",
2516
+ "max" : "2147483647"
2517
+ },
2518
+ ],
2519
+ "range" : {
2520
+ "min" : "0",
2521
+ "max" : "2147483647"
2522
+ },
2523
+ },
2524
+ },
2525
+ "access" : "readonly",
2526
+ "description" :
2527
+ """The group from which an error-free frame whose
2528
+ source address is equal to the corresponding instance
2529
+ of rptrAddrSearchAddress has been received. The
2530
+ value of this object is undefined when the
2531
+ corresponding instance of rptrAddrSearchState is
2532
+ equal to 'none' or 'multiple'.""",
2533
+ }, # column
2534
+ "rptrAddrSearchPort" : {
2535
+ "nodetype" : "column",
2536
+ "moduleName" : "SNMP-REPEATER-MIB",
2537
+ "oid" : "1.3.6.1.2.1.22.3.1.1.1.6",
2538
+ "status" : "current",
2539
+ "syntax" : {
2540
+ "type" : {
2541
+ "basetype" : "Integer32",
2542
+ "ranges" : [
2543
+ {
2544
+ "min" : "0",
2545
+ "max" : "2147483647"
2546
+ },
2547
+ ],
2548
+ "range" : {
2549
+ "min" : "0",
2550
+ "max" : "2147483647"
2551
+ },
2552
+ },
2553
+ },
2554
+ "access" : "readonly",
2555
+ "description" :
2556
+ """The port rom which an error-free frame whose
2557
+ source address is equal to the corresponding instance
2558
+ of rptrAddrSearchAddress has been received. The
2559
+ value of this object is undefined when the
2560
+ corresponding instance of rptrAddrSearchState is
2561
+ equal to 'none' or 'multiple'.""",
2562
+ }, # column
2563
+ "rptrAddrSearchOwner" : {
2564
+ "nodetype" : "column",
2565
+ "moduleName" : "SNMP-REPEATER-MIB",
2566
+ "oid" : "1.3.6.1.2.1.22.3.1.1.1.7",
2567
+ "status" : "current",
2568
+ "syntax" : {
2569
+ "type" : { "module" :"IF-MIB", "name" : "OwnerString"},
2570
+ },
2571
+ "access" : "readwrite",
2572
+ "description" :
2573
+ """The entity which currently has 'ownership' of this
2574
+ rptrAddrSearchEntry.""",
2575
+ }, # column
2576
+ "rptrAddrTrackGroupInfo" : {
2577
+ "nodetype" : "node",
2578
+ "moduleName" : "SNMP-REPEATER-MIB",
2579
+ "oid" : "1.3.6.1.2.1.22.3.2",
2580
+ }, # node
2581
+ "rptrAddrTrackPortInfo" : {
2582
+ "nodetype" : "node",
2583
+ "moduleName" : "SNMP-REPEATER-MIB",
2584
+ "oid" : "1.3.6.1.2.1.22.3.3",
2585
+ }, # node
2586
+ "rptrAddrTrackTable" : {
2587
+ "nodetype" : "table",
2588
+ "moduleName" : "SNMP-REPEATER-MIB",
2589
+ "oid" : "1.3.6.1.2.1.22.3.3.1",
2590
+ "status" : "current",
2591
+ "description" :
2592
+ """Table of address mapping information about the
2593
+ ports.""",
2594
+ }, # table
2595
+ "rptrAddrTrackEntry" : {
2596
+ "nodetype" : "row",
2597
+ "moduleName" : "SNMP-REPEATER-MIB",
2598
+ "oid" : "1.3.6.1.2.1.22.3.3.1.1",
2599
+ "status" : "current",
2600
+ "linkage" : [
2601
+ "rptrAddrTrackGroupIndex",
2602
+ "rptrAddrTrackPortIndex",
2603
+ ],
2604
+ "description" :
2605
+ """An entry in the table, containing address mapping
2606
+ information about a single port.""",
2607
+ }, # row
2608
+ "rptrAddrTrackGroupIndex" : {
2609
+ "nodetype" : "column",
2610
+ "moduleName" : "SNMP-REPEATER-MIB",
2611
+ "oid" : "1.3.6.1.2.1.22.3.3.1.1.1",
2612
+ "status" : "current",
2613
+ "syntax" : {
2614
+ "type" : {
2615
+ "basetype" : "Integer32",
2616
+ "ranges" : [
2617
+ {
2618
+ "min" : "1",
2619
+ "max" : "2147483647"
2620
+ },
2621
+ ],
2622
+ "range" : {
2623
+ "min" : "1",
2624
+ "max" : "2147483647"
2625
+ },
2626
+ },
2627
+ },
2628
+ "access" : "readonly",
2629
+ "description" :
2630
+ """This object identifies the group containing the
2631
+ port for which this entry contains information.""",
2632
+ }, # column
2633
+ "rptrAddrTrackPortIndex" : {
2634
+ "nodetype" : "column",
2635
+ "moduleName" : "SNMP-REPEATER-MIB",
2636
+ "oid" : "1.3.6.1.2.1.22.3.3.1.1.2",
2637
+ "status" : "current",
2638
+ "syntax" : {
2639
+ "type" : {
2640
+ "basetype" : "Integer32",
2641
+ "ranges" : [
2642
+ {
2643
+ "min" : "1",
2644
+ "max" : "2147483647"
2645
+ },
2646
+ ],
2647
+ "range" : {
2648
+ "min" : "1",
2649
+ "max" : "2147483647"
2650
+ },
2651
+ },
2652
+ },
2653
+ "access" : "readonly",
2654
+ "description" :
2655
+ """This object identifies the port within the group
2656
+ for which this entry contains information.""",
2657
+ "reference" :
2658
+ """[IEEE 802.3 Mgt], 30.4.3.1.1, aPortID.""",
2659
+ }, # column
2660
+ "rptrAddrTrackLastSourceAddress" : {
2661
+ "nodetype" : "column",
2662
+ "moduleName" : "SNMP-REPEATER-MIB",
2663
+ "oid" : "1.3.6.1.2.1.22.3.3.1.1.3",
2664
+ "status" : "deprecated",
2665
+ "syntax" : {
2666
+ "type" : { "module" :"SNMPv2-TC", "name" : "MacAddress"},
2667
+ },
2668
+ "access" : "readonly",
2669
+ "description" :
2670
+ """********* THIS OBJECT IS DEPRECATED **********
2671
+ This object is the SourceAddress of the last
2672
+ readable frame (i.e., counted by
2673
+ rptrMonitorPortReadableFrames) received by this
2674
+ port.
2675
+
2676
+ This object has been deprecated because its value
2677
+ is undefined when no frames have been observed on
2678
+ this port. The replacement object is
2679
+ rptrAddrTrackNewLastSrcAddress.""",
2680
+ "reference" :
2681
+ """[IEEE 802.3 Mgt], 30.4.3.1.18, aLastSourceAddress.""",
2682
+ }, # column
2683
+ "rptrAddrTrackSourceAddrChanges" : {
2684
+ "nodetype" : "column",
2685
+ "moduleName" : "SNMP-REPEATER-MIB",
2686
+ "oid" : "1.3.6.1.2.1.22.3.3.1.1.4",
2687
+ "status" : "current",
2688
+ "syntax" : {
2689
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
2690
+ },
2691
+ "access" : "readonly",
2692
+ "description" :
2693
+ """This counter is incremented by one for each time
2694
+ that the rptrAddrTrackLastSourceAddress attribute
2695
+ for this port has changed.
2696
+
2697
+ This may indicate whether a link is connected to a
2698
+ single DTE or another multi-user segment.
2699
+
2700
+ A discontinuity may occur in the value when the
2701
+ value of object rptrMonitorPortLastChange changes.
2702
+
2703
+ The approximate minimum time for rollover of this
2704
+ counter is 81 hours in a 10Mb/s repeater.""",
2705
+ "reference" :
2706
+ """[IEEE 802.3 Mgt], 30.4.3.1.19, aSourceAddressChanges.""",
2707
+ }, # column
2708
+ "rptrAddrTrackNewLastSrcAddress" : {
2709
+ "nodetype" : "column",
2710
+ "moduleName" : "SNMP-REPEATER-MIB",
2711
+ "oid" : "1.3.6.1.2.1.22.3.3.1.1.5",
2712
+ "status" : "current",
2713
+ "syntax" : {
2714
+ "type" : { "module" :"SNMP-REPEATER-MIB", "name" : "OptMacAddr"},
2715
+ },
2716
+ "access" : "readonly",
2717
+ "description" :
2718
+ """This object is the SourceAddress of the last
2719
+ readable frame (i.e., counted by
2720
+ rptrMonitorPortReadableFrames) received by this
2721
+ port. If no frames have been received by this
2722
+ port since the agent began monitoring the port
2723
+ activity, the agent shall return a string of
2724
+ length zero.""",
2725
+ "reference" :
2726
+ """[IEEE 802.3 Mgt], 30.4.3.1.18, aLastSourceAddress.""",
2727
+ }, # column
2728
+ "rptrAddrTrackCapacity" : {
2729
+ "nodetype" : "column",
2730
+ "moduleName" : "SNMP-REPEATER-MIB",
2731
+ "oid" : "1.3.6.1.2.1.22.3.3.1.1.6",
2732
+ "status" : "current",
2733
+ "syntax" : {
2734
+ "type" : { "module" :"", "name" : "Integer32"},
2735
+ },
2736
+ "access" : "readonly",
2737
+ "description" :
2738
+ """The maximum number of addresses that can be
2739
+ detected on this port. This value indicates
2740
+ to the maximum number of entries in the
2741
+ rptrExtAddrTrackTable relative to this port.
2742
+
2743
+ If this object has the value of 1, the agent
2744
+ implements only the LastSourceAddress mechanism
2745
+ described by RFC 1368 or RFC 1516.""",
2746
+ }, # column
2747
+ "rptrExtAddrTrackTable" : {
2748
+ "nodetype" : "table",
2749
+ "moduleName" : "SNMP-REPEATER-MIB",
2750
+ "oid" : "1.3.6.1.2.1.22.3.3.2",
2751
+ "status" : "current",
2752
+ "description" :
2753
+ """A table to extend the address tracking table (i.e.,
2754
+ rptrAddrTrackTable) with a list of source MAC
2755
+ addresses that were recently received on each port.
2756
+ The number of ports is the same as the number
2757
+ of entries in table rptrPortTable. The number of
2758
+ entries in this table depends on the agent/repeater
2759
+ implementation and the number of different
2760
+ addresses received on each port.
2761
+
2762
+ The first entry for each port contains
2763
+ the same MAC address that is given by the
2764
+ rptrAddrTrackNewLastSrcAddress for that port.
2765
+
2766
+ Entries in this table for a particular port are
2767
+ retained when that port is switched from one
2768
+ repeater to another.
2769
+
2770
+ The ordering of MAC addresses listed for a
2771
+ particular port is implementation dependent.""",
2772
+ }, # table
2773
+ "rptrExtAddrTrackEntry" : {
2774
+ "nodetype" : "row",
2775
+ "moduleName" : "SNMP-REPEATER-MIB",
2776
+ "oid" : "1.3.6.1.2.1.22.3.3.2.1",
2777
+ "status" : "current",
2778
+ "linkage" : [
2779
+ "rptrAddrTrackGroupIndex",
2780
+ "rptrAddrTrackPortIndex",
2781
+ "rptrExtAddrTrackMacIndex",
2782
+ ],
2783
+ "description" :
2784
+ """A row in the table of extended address tracking
2785
+ information for ports. Entries can not be directly
2786
+ created or deleted via SNMP operations.""",
2787
+ }, # row
2788
+ "rptrExtAddrTrackMacIndex" : {
2789
+ "nodetype" : "column",
2790
+ "moduleName" : "SNMP-REPEATER-MIB",
2791
+ "oid" : "1.3.6.1.2.1.22.3.3.2.1.1",
2792
+ "status" : "current",
2793
+ "syntax" : {
2794
+ "type" : {
2795
+ "basetype" : "Integer32",
2796
+ "ranges" : [
2797
+ {
2798
+ "min" : "1",
2799
+ "max" : "2147483647"
2800
+ },
2801
+ ],
2802
+ "range" : {
2803
+ "min" : "1",
2804
+ "max" : "2147483647"
2805
+ },
2806
+ },
2807
+ },
2808
+ "access" : "readonly",
2809
+ "description" :
2810
+ """The index of a source MAC address seen on
2811
+ the port.
2812
+
2813
+ The ordering of MAC addresses listed for a
2814
+ particular port is implementation dependent.
2815
+
2816
+ There is no implied relationship between a
2817
+ particular index and a particular MAC
2818
+ address. The index for a particular MAC
2819
+ address may change without notice.""",
2820
+ }, # column
2821
+ "rptrExtAddrTrackSourceAddress" : {
2822
+ "nodetype" : "column",
2823
+ "moduleName" : "SNMP-REPEATER-MIB",
2824
+ "oid" : "1.3.6.1.2.1.22.3.3.2.1.2",
2825
+ "status" : "current",
2826
+ "syntax" : {
2827
+ "type" : { "module" :"SNMPv2-TC", "name" : "MacAddress"},
2828
+ },
2829
+ "access" : "readonly",
2830
+ "description" :
2831
+ """The source MAC address from a readable frame
2832
+ (i.e., counted by rptrMonitorPortReadableFrames)
2833
+ recently received by the port.""",
2834
+ "reference" :
2835
+ """[IEEE 802.3 Mgt], 30.4.3.1.18, aLastSourceAddress.""",
2836
+ }, # column
2837
+ "rptrTopNPackage" : {
2838
+ "nodetype" : "node",
2839
+ "moduleName" : "SNMP-REPEATER-MIB",
2840
+ "oid" : "1.3.6.1.2.1.22.4",
2841
+ }, # node
2842
+ "rptrTopNRptrInfo" : {
2843
+ "nodetype" : "node",
2844
+ "moduleName" : "SNMP-REPEATER-MIB",
2845
+ "oid" : "1.3.6.1.2.1.22.4.1",
2846
+ }, # node
2847
+ "rptrTopNGroupInfo" : {
2848
+ "nodetype" : "node",
2849
+ "moduleName" : "SNMP-REPEATER-MIB",
2850
+ "oid" : "1.3.6.1.2.1.22.4.2",
2851
+ }, # node
2852
+ "rptrTopNPortInfo" : {
2853
+ "nodetype" : "node",
2854
+ "moduleName" : "SNMP-REPEATER-MIB",
2855
+ "oid" : "1.3.6.1.2.1.22.4.3",
2856
+ }, # node
2857
+ "rptrTopNPortControlTable" : {
2858
+ "nodetype" : "table",
2859
+ "moduleName" : "SNMP-REPEATER-MIB",
2860
+ "oid" : "1.3.6.1.2.1.22.4.3.1",
2861
+ "status" : "current",
2862
+ "description" :
2863
+ """A table of control records for reports on the top `N'
2864
+ ports for the rate of a selected counter. The number
2865
+ of entries depends on the configuration of the agent.
2866
+ The maximum number of entries is implementation
2867
+ dependent.""",
2868
+ }, # table
2869
+ "rptrTopNPortControlEntry" : {
2870
+ "nodetype" : "row",
2871
+ "moduleName" : "SNMP-REPEATER-MIB",
2872
+ "oid" : "1.3.6.1.2.1.22.4.3.1.1",
2873
+ "create" : "true",
2874
+ "status" : "current",
2875
+ "linkage" : [
2876
+ "rptrTopNPortControlIndex",
2877
+ ],
2878
+ "description" :
2879
+ """A set of parameters that control the creation of a
2880
+ report of the top N ports according to several metrics.""",
2881
+ }, # row
2882
+ "rptrTopNPortControlIndex" : {
2883
+ "nodetype" : "column",
2884
+ "moduleName" : "SNMP-REPEATER-MIB",
2885
+ "oid" : "1.3.6.1.2.1.22.4.3.1.1.1",
2886
+ "status" : "current",
2887
+ "syntax" : {
2888
+ "type" : {
2889
+ "basetype" : "Integer32",
2890
+ "ranges" : [
2891
+ {
2892
+ "min" : "1",
2893
+ "max" : "65535"
2894
+ },
2895
+ ],
2896
+ "range" : {
2897
+ "min" : "1",
2898
+ "max" : "65535"
2899
+ },
2900
+ },
2901
+ },
2902
+ "access" : "readonly",
2903
+ "description" :
2904
+ """An index that uniquely identifies an entry in the
2905
+ rptrTopNPortControl table. Each such entry defines
2906
+ one top N report prepared for a repeater or system.""",
2907
+ }, # column
2908
+ "rptrTopNPortRepeaterId" : {
2909
+ "nodetype" : "column",
2910
+ "moduleName" : "SNMP-REPEATER-MIB",
2911
+ "oid" : "1.3.6.1.2.1.22.4.3.1.1.2",
2912
+ "status" : "current",
2913
+ "syntax" : {
2914
+ "type" : {
2915
+ "basetype" : "Integer32",
2916
+ "ranges" : [
2917
+ {
2918
+ "min" : "0",
2919
+ "max" : "2147483647"
2920
+ },
2921
+ ],
2922
+ "range" : {
2923
+ "min" : "0",
2924
+ "max" : "2147483647"
2925
+ },
2926
+ },
2927
+ },
2928
+ "access" : "readwrite",
2929
+ "description" :
2930
+ """Identifies the repeater for which a top N report will
2931
+ be prepared (see rptrInfoId). If the value of this
2932
+ object is positive, only ports assigned to this repeater
2933
+ will be used to form the list in which to order the
2934
+ Top N table. If this value is zero, all ports will be
2935
+ eligible for inclusion on the list.
2936
+
2937
+ The value of this object may not be modified if the
2938
+ associated rptrTopNPortRowStatus object is equal to
2939
+ active(1).
2940
+ If, for a particular row in this table, the repeater
2941
+ specified by the value of this object goes away (is
2942
+ removed from the rptrInfoTable) while the associated
2943
+ rptrTopNPortRowStatus object is equal to active(1),
2944
+ the row in this table is preserved by the agent but
2945
+ the value of rptrTopNPortRowStatus is changed to
2946
+ notInService(2), and the agent may time out the row
2947
+ if appropriate. If the specified repeater comes
2948
+ back (reappears in the rptrInfoTable) before the row
2949
+ has been timed out, the management station must set
2950
+ the value of the rptrTopNPortRowStatus object back
2951
+ to active(1) if desired (the agent doesn't do this
2952
+ automatically).""",
2953
+ }, # column
2954
+ "rptrTopNPortRateBase" : {
2955
+ "nodetype" : "column",
2956
+ "moduleName" : "SNMP-REPEATER-MIB",
2957
+ "oid" : "1.3.6.1.2.1.22.4.3.1.1.3",
2958
+ "status" : "current",
2959
+ "syntax" : {
2960
+ "type" : {
2961
+ "basetype" : "Enumeration",
2962
+ "readableFrames" : {
2963
+ "nodetype" : "namednumber",
2964
+ "number" : "1"
2965
+ },
2966
+ "readableOctets" : {
2967
+ "nodetype" : "namednumber",
2968
+ "number" : "2"
2969
+ },
2970
+ "fcsErrors" : {
2971
+ "nodetype" : "namednumber",
2972
+ "number" : "3"
2973
+ },
2974
+ "alignmentErrors" : {
2975
+ "nodetype" : "namednumber",
2976
+ "number" : "4"
2977
+ },
2978
+ "frameTooLongs" : {
2979
+ "nodetype" : "namednumber",
2980
+ "number" : "5"
2981
+ },
2982
+ "shortEvents" : {
2983
+ "nodetype" : "namednumber",
2984
+ "number" : "6"
2985
+ },
2986
+ "runts" : {
2987
+ "nodetype" : "namednumber",
2988
+ "number" : "7"
2989
+ },
2990
+ "collisions" : {
2991
+ "nodetype" : "namednumber",
2992
+ "number" : "8"
2993
+ },
2994
+ "lateEvents" : {
2995
+ "nodetype" : "namednumber",
2996
+ "number" : "9"
2997
+ },
2998
+ "veryLongEvents" : {
2999
+ "nodetype" : "namednumber",
3000
+ "number" : "10"
3001
+ },
3002
+ "dataRateMismatches" : {
3003
+ "nodetype" : "namednumber",
3004
+ "number" : "11"
3005
+ },
3006
+ "autoPartitions" : {
3007
+ "nodetype" : "namednumber",
3008
+ "number" : "12"
3009
+ },
3010
+ "totalErrors" : {
3011
+ "nodetype" : "namednumber",
3012
+ "number" : "13"
3013
+ },
3014
+ "isolates" : {
3015
+ "nodetype" : "namednumber",
3016
+ "number" : "14"
3017
+ },
3018
+ "symbolErrors" : {
3019
+ "nodetype" : "namednumber",
3020
+ "number" : "15"
3021
+ },
3022
+ },
3023
+ },
3024
+ "access" : "readwrite",
3025
+ "description" :
3026
+ """The monitored variable, which the rptrTopNPortRate
3027
+ variable is based upon.
3028
+
3029
+ The value of this object may not be modified if
3030
+ the associated rptrTopNPortRowStatus object has
3031
+ a value of active(1).""",
3032
+ }, # column
3033
+ "rptrTopNPortTimeRemaining" : {
3034
+ "nodetype" : "column",
3035
+ "moduleName" : "SNMP-REPEATER-MIB",
3036
+ "oid" : "1.3.6.1.2.1.22.4.3.1.1.4",
3037
+ "status" : "current",
3038
+ "syntax" : {
3039
+ "type" : {
3040
+ "basetype" : "Integer32",
3041
+ "ranges" : [
3042
+ {
3043
+ "min" : "0",
3044
+ "max" : "2147483647"
3045
+ },
3046
+ ],
3047
+ "range" : {
3048
+ "min" : "0",
3049
+ "max" : "2147483647"
3050
+ },
3051
+ },
3052
+ },
3053
+ "access" : "readwrite",
3054
+ "default" : "0",
3055
+ "description" :
3056
+ """The number of seconds left in the report
3057
+ currently being collected. When this object
3058
+ is modified by the management station, a new
3059
+ collection is started, possibly aborting a
3060
+ currently running report. The new value is
3061
+ used as the requested duration of this report,
3062
+ which is loaded into the associated
3063
+ rptrTopNPortDuration object.
3064
+
3065
+ When this object is set to a non-zero value,
3066
+ any associated rptrTopNPortEntries shall be
3067
+ made inaccessible by the agent. While the value
3068
+ of this object is non-zero, it decrements by one
3069
+ per second until it reaches zero. During this
3070
+ time, all associated rptrTopNPortEntries shall
3071
+ remain inaccessible. At the time that this object
3072
+ decrements to zero, the report is made accessible
3073
+ in the rptrTopNPortTable. Thus, the rptrTopNPort
3074
+ table needs to be created only at the end of the
3075
+ collection interval.
3076
+
3077
+ If the value of this object is set to zero
3078
+ while the associated report is running, the
3079
+ running report is aborted and no associated
3080
+ rptrTopNPortEntries are created.""",
3081
+ }, # column
3082
+ "rptrTopNPortDuration" : {
3083
+ "nodetype" : "column",
3084
+ "moduleName" : "SNMP-REPEATER-MIB",
3085
+ "oid" : "1.3.6.1.2.1.22.4.3.1.1.5",
3086
+ "status" : "current",
3087
+ "syntax" : {
3088
+ "type" : {
3089
+ "basetype" : "Integer32",
3090
+ "ranges" : [
3091
+ {
3092
+ "min" : "0",
3093
+ "max" : "2147483647"
3094
+ },
3095
+ ],
3096
+ "range" : {
3097
+ "min" : "0",
3098
+ "max" : "2147483647"
3099
+ },
3100
+ },
3101
+ },
3102
+ "access" : "readonly",
3103
+ "description" :
3104
+ """The number of seconds that this report has
3105
+ collected during the last sampling interval,
3106
+ or if this report is currently being collected,
3107
+ the number of seconds that this report is being
3108
+ collected during this sampling interval.
3109
+
3110
+ When the associated rptrTopNPortTimeRemaining
3111
+ object is set, this object shall be set by the
3112
+ agent to the same value and shall not be modified
3113
+ until the next time the rptrTopNPortTimeRemaining
3114
+ is set.
3115
+
3116
+ This value shall be zero if no reports have been
3117
+ requested for this rptrTopNPortControlEntry.""",
3118
+ }, # column
3119
+ "rptrTopNPortRequestedSize" : {
3120
+ "nodetype" : "column",
3121
+ "moduleName" : "SNMP-REPEATER-MIB",
3122
+ "oid" : "1.3.6.1.2.1.22.4.3.1.1.6",
3123
+ "status" : "current",
3124
+ "syntax" : {
3125
+ "type" : { "module" :"", "name" : "Integer32"},
3126
+ },
3127
+ "access" : "readwrite",
3128
+ "default" : "10",
3129
+ "description" :
3130
+ """The maximum number of repeater ports requested
3131
+ for the Top N Table.
3132
+
3133
+ When this object is created or modified, the
3134
+ agent should set rptrTopNPortGrantedSize as close
3135
+ to this object as is possible for the particular
3136
+ implementation and available resources.""",
3137
+ }, # column
3138
+ "rptrTopNPortGrantedSize" : {
3139
+ "nodetype" : "column",
3140
+ "moduleName" : "SNMP-REPEATER-MIB",
3141
+ "oid" : "1.3.6.1.2.1.22.4.3.1.1.7",
3142
+ "status" : "current",
3143
+ "syntax" : {
3144
+ "type" : {
3145
+ "basetype" : "Integer32",
3146
+ "ranges" : [
3147
+ {
3148
+ "min" : "0",
3149
+ "max" : "65535"
3150
+ },
3151
+ ],
3152
+ "range" : {
3153
+ "min" : "0",
3154
+ "max" : "65535"
3155
+ },
3156
+ },
3157
+ },
3158
+ "access" : "readonly",
3159
+ "description" :
3160
+ """The maximum number of repeater ports in the
3161
+ top N table.
3162
+
3163
+ When the associated rptrTopNPortRequestedSize object is
3164
+ created or modified, the agent should set this object as
3165
+ closely to the requested value as is possible for the
3166
+ particular implementation and available resources. The
3167
+ agent must not lower this value except as a result of a
3168
+ set to the associated rptrTopNPortRequestedSize object.""",
3169
+ }, # column
3170
+ "rptrTopNPortStartTime" : {
3171
+ "nodetype" : "column",
3172
+ "moduleName" : "SNMP-REPEATER-MIB",
3173
+ "oid" : "1.3.6.1.2.1.22.4.3.1.1.8",
3174
+ "status" : "current",
3175
+ "syntax" : {
3176
+ "type" : { "module" :"SNMPv2-TC", "name" : "TimeStamp"},
3177
+ },
3178
+ "access" : "readonly",
3179
+ "description" :
3180
+ """The value of sysUpTime when this top N report was
3181
+ last started. In other words, this is the time that
3182
+ the associated rptrTopNPortTimeRemaining object was
3183
+ modified to start the requested report.
3184
+
3185
+ If the report has not yet been started, the value
3186
+ of this object is zero.""",
3187
+ }, # column
3188
+ "rptrTopNPortOwner" : {
3189
+ "nodetype" : "column",
3190
+ "moduleName" : "SNMP-REPEATER-MIB",
3191
+ "oid" : "1.3.6.1.2.1.22.4.3.1.1.9",
3192
+ "status" : "current",
3193
+ "syntax" : {
3194
+ "type" : { "module" :"IF-MIB", "name" : "OwnerString"},
3195
+ },
3196
+ "access" : "readwrite",
3197
+ "description" :
3198
+ """The entity that configured this entry and is
3199
+ using the resources assigned to it.""",
3200
+ }, # column
3201
+ "rptrTopNPortRowStatus" : {
3202
+ "nodetype" : "column",
3203
+ "moduleName" : "SNMP-REPEATER-MIB",
3204
+ "oid" : "1.3.6.1.2.1.22.4.3.1.1.10",
3205
+ "status" : "current",
3206
+ "syntax" : {
3207
+ "type" : { "module" :"SNMPv2-TC", "name" : "RowStatus"},
3208
+ },
3209
+ "access" : "readwrite",
3210
+ "description" :
3211
+ """The status of this row.
3212
+
3213
+ If the value of this object is not equal to
3214
+ active(1), all associated entries in the
3215
+ rptrTopNPortTable shall be deleted by the
3216
+ agent.""",
3217
+ }, # column
3218
+ "rptrTopNPortTable" : {
3219
+ "nodetype" : "table",
3220
+ "moduleName" : "SNMP-REPEATER-MIB",
3221
+ "oid" : "1.3.6.1.2.1.22.4.3.2",
3222
+ "status" : "current",
3223
+ "description" :
3224
+ """A table of reports for the top `N' ports based on
3225
+ setting of associated control table entries. The
3226
+ maximum number of entries depends on the number
3227
+ of entries in table rptrTopNPortControlTable and
3228
+ the value of object rptrTopNPortGrantedSize for
3229
+ each entry.
3230
+
3231
+ For each entry in the rptrTopNPortControlTable,
3232
+ repeater ports with the highest value of
3233
+ rptrTopNPortRate shall be placed in this table
3234
+ in decreasing order of that rate until there is
3235
+ no more room or until there are no more ports.""",
3236
+ }, # table
3237
+ "rptrTopNPortEntry" : {
3238
+ "nodetype" : "row",
3239
+ "moduleName" : "SNMP-REPEATER-MIB",
3240
+ "oid" : "1.3.6.1.2.1.22.4.3.2.1",
3241
+ "status" : "current",
3242
+ "linkage" : [
3243
+ "rptrTopNPortControlIndex",
3244
+ "rptrTopNPortIndex",
3245
+ ],
3246
+ "description" :
3247
+ """A set of statistics for a repeater port that is
3248
+ part of a top N report.""",
3249
+ }, # row
3250
+ "rptrTopNPortIndex" : {
3251
+ "nodetype" : "column",
3252
+ "moduleName" : "SNMP-REPEATER-MIB",
3253
+ "oid" : "1.3.6.1.2.1.22.4.3.2.1.1",
3254
+ "status" : "current",
3255
+ "syntax" : {
3256
+ "type" : {
3257
+ "basetype" : "Integer32",
3258
+ "ranges" : [
3259
+ {
3260
+ "min" : "1",
3261
+ "max" : "65535"
3262
+ },
3263
+ ],
3264
+ "range" : {
3265
+ "min" : "1",
3266
+ "max" : "65535"
3267
+ },
3268
+ },
3269
+ },
3270
+ "access" : "readonly",
3271
+ "description" :
3272
+ """An index that uniquely identifies an entry in
3273
+ the rptrTopNPort table among those in the same
3274
+ report. This index is between 1 and N, where N
3275
+ is the number of entries in this report. Increasing
3276
+ values of rptrTopNPortIndex shall be assigned to
3277
+ entries with decreasing values of rptrTopNPortRate
3278
+ until index N is assigned to the entry with the
3279
+ lowest value of rptrTopNPortRate or there are no
3280
+ more rptrTopNPortEntries.
3281
+
3282
+ No ports are included in a report where their
3283
+ value of rptrTopNPortRate would be zero.""",
3284
+ }, # column
3285
+ "rptrTopNPortGroupIndex" : {
3286
+ "nodetype" : "column",
3287
+ "moduleName" : "SNMP-REPEATER-MIB",
3288
+ "oid" : "1.3.6.1.2.1.22.4.3.2.1.2",
3289
+ "status" : "current",
3290
+ "syntax" : {
3291
+ "type" : {
3292
+ "basetype" : "Integer32",
3293
+ "ranges" : [
3294
+ {
3295
+ "min" : "1",
3296
+ "max" : "2147483647"
3297
+ },
3298
+ ],
3299
+ "range" : {
3300
+ "min" : "1",
3301
+ "max" : "2147483647"
3302
+ },
3303
+ },
3304
+ },
3305
+ "access" : "readonly",
3306
+ "description" :
3307
+ """This object identifes the group containing
3308
+ the port for this entry. (See also object
3309
+ type rptrGroupIndex.)""",
3310
+ }, # column
3311
+ "rptrTopNPortPortIndex" : {
3312
+ "nodetype" : "column",
3313
+ "moduleName" : "SNMP-REPEATER-MIB",
3314
+ "oid" : "1.3.6.1.2.1.22.4.3.2.1.3",
3315
+ "status" : "current",
3316
+ "syntax" : {
3317
+ "type" : {
3318
+ "basetype" : "Integer32",
3319
+ "ranges" : [
3320
+ {
3321
+ "min" : "1",
3322
+ "max" : "2147483647"
3323
+ },
3324
+ ],
3325
+ "range" : {
3326
+ "min" : "1",
3327
+ "max" : "2147483647"
3328
+ },
3329
+ },
3330
+ },
3331
+ "access" : "readonly",
3332
+ "description" :
3333
+ """The index of the repeater port.
3334
+ (See object type rptrPortIndex.)""",
3335
+ }, # column
3336
+ "rptrTopNPortRate" : {
3337
+ "nodetype" : "column",
3338
+ "moduleName" : "SNMP-REPEATER-MIB",
3339
+ "oid" : "1.3.6.1.2.1.22.4.3.2.1.4",
3340
+ "status" : "current",
3341
+ "syntax" : {
3342
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Gauge32"},
3343
+ },
3344
+ "access" : "readonly",
3345
+ "description" :
3346
+ """The amount of change in the selected variable
3347
+ during this sampling interval for the identified
3348
+ port. The selected variable is that port's
3349
+ instance of the object selected by
3350
+ rptrTopNPortRateBase.""",
3351
+ }, # column
3352
+ "snmpRptrMod" : {
3353
+ "nodetype" : "node",
3354
+ "moduleName" : "SNMP-REPEATER-MIB",
3355
+ "oid" : "1.3.6.1.2.1.22.5",
3356
+ "status" : "current",
3357
+ }, # node
3358
+ "snmpRptrModConf" : {
3359
+ "nodetype" : "node",
3360
+ "moduleName" : "SNMP-REPEATER-MIB",
3361
+ "oid" : "1.3.6.1.2.1.22.5.1",
3362
+ }, # node
3363
+ "snmpRptrModCompls" : {
3364
+ "nodetype" : "node",
3365
+ "moduleName" : "SNMP-REPEATER-MIB",
3366
+ "oid" : "1.3.6.1.2.1.22.5.1.1",
3367
+ }, # node
3368
+ "snmpRptrModObjGrps" : {
3369
+ "nodetype" : "node",
3370
+ "moduleName" : "SNMP-REPEATER-MIB",
3371
+ "oid" : "1.3.6.1.2.1.22.5.1.2",
3372
+ }, # node
3373
+ "snmpRptrModNotGrps" : {
3374
+ "nodetype" : "node",
3375
+ "moduleName" : "SNMP-REPEATER-MIB",
3376
+ "oid" : "1.3.6.1.2.1.22.5.1.3",
3377
+ }, # node
3378
+ }, # nodes
3379
+
3380
+ "notifications" : {
3381
+ "rptrHealth" : {
3382
+ "nodetype" : "notification",
3383
+ "moduleName" : "SNMP-REPEATER-MIB",
3384
+ "oid" : "1.3.6.1.2.1.22.0.1",
3385
+ "status" : "deprecated",
3386
+ "objects" : {
3387
+ "rptrOperStatus" : {
3388
+ "nodetype" : "object",
3389
+ "module" : "SNMP-REPEATER-MIB"
3390
+ },
3391
+ },
3392
+ "description" :
3393
+ """********* THIS OBJECT IS DEPRECATED **********
3394
+
3395
+ In a system containing a single managed repeater,
3396
+ the rptrHealth notification conveys information
3397
+ related to the operational status of the repeater.
3398
+ It is sent either when the value of
3399
+ rptrOperStatus changes, or upon completion of a
3400
+ non-disruptive test.
3401
+
3402
+ The rptrHealth notification must contain the
3403
+ rptrOperStatus object. The agent may optionally
3404
+ include the rptrHealthText object in the varBind
3405
+ list. See the rptrOperStatus and rptrHealthText
3406
+ objects for descriptions of the information that
3407
+ is sent.
3408
+
3409
+ The agent must throttle the generation of
3410
+ consecutive rptrHealth traps so that there is at
3411
+ least a five-second gap between traps of this
3412
+ type. When traps are throttled, they are dropped,
3413
+ not queued for sending at a future time. (Note
3414
+ that 'generating' a trap means sending to all
3415
+ configured recipients.)""",
3416
+ "reference" :
3417
+ """[IEEE 802.3 Mgt], 30.4.1.3.1, nRepeaterHealth
3418
+ notification.""",
3419
+ }, # notification
3420
+ "rptrGroupChange" : {
3421
+ "nodetype" : "notification",
3422
+ "moduleName" : "SNMP-REPEATER-MIB",
3423
+ "oid" : "1.3.6.1.2.1.22.0.2",
3424
+ "status" : "deprecated",
3425
+ "objects" : {
3426
+ "rptrGroupIndex" : {
3427
+ "nodetype" : "object",
3428
+ "module" : "SNMP-REPEATER-MIB"
3429
+ },
3430
+ },
3431
+ "description" :
3432
+ """********* THIS OBJECT IS DEPRECATED **********
3433
+
3434
+ In a system containing a single managed repeater,
3435
+ this notification is sent when a change occurs in the
3436
+ group structure of the repeater. This occurs only
3437
+ when a group is logically or physically removed
3438
+ from or added to a repeater. The varBind list
3439
+ contains the identifier of the group that was
3440
+ removed or added.
3441
+
3442
+ The agent must throttle the generation of
3443
+ consecutive rptrGroupChange traps for the same
3444
+ group so that there is at least a five-second gap
3445
+ between traps of this type. When traps are
3446
+ throttled, they are dropped, not queued for
3447
+ sending at a future time. (Note that 'generating'
3448
+ a trap means sending to all configured
3449
+ recipients.)""",
3450
+ "reference" :
3451
+ """[IEEE 802.3 Mgt], 30.4.1.3.3, nGroupMapChange
3452
+ notification.""",
3453
+ }, # notification
3454
+ "rptrResetEvent" : {
3455
+ "nodetype" : "notification",
3456
+ "moduleName" : "SNMP-REPEATER-MIB",
3457
+ "oid" : "1.3.6.1.2.1.22.0.3",
3458
+ "status" : "deprecated",
3459
+ "objects" : {
3460
+ "rptrOperStatus" : {
3461
+ "nodetype" : "object",
3462
+ "module" : "SNMP-REPEATER-MIB"
3463
+ },
3464
+ },
3465
+ "description" :
3466
+ """********* THIS OBJECT IS DEPRECATED **********
3467
+
3468
+ In a system containing a single managed repeater-unit,
3469
+ the rptrResetEvent notification conveys information
3470
+ related to the operational status of the repeater.
3471
+ This trap is sent on completion of a repeater
3472
+ reset action. A repeater reset action is defined
3473
+ as an a transition to the START state of Fig 9-2
3474
+ in section 9 [IEEE 802.3 Std], when triggered by a
3475
+ management command (e.g., an SNMP Set on the
3476
+ rptrReset object).
3477
+
3478
+ The agent must throttle the generation of
3479
+ consecutive rptrResetEvent traps so that there is
3480
+ at least a five-second gap between traps of this
3481
+ type. When traps are throttled, they are dropped,
3482
+ not queued for sending at a future time. (Note
3483
+ that 'generating' a trap means sending to all
3484
+ configured recipients.)
3485
+
3486
+ The rptrResetEvent trap is not sent when the agent
3487
+ restarts and sends an SNMP coldStart or warmStart
3488
+ trap. However, it is recommended that a repeater
3489
+ agent send the rptrOperStatus object as an
3490
+ optional object with its coldStart and warmStart
3491
+ trap PDUs.
3492
+
3493
+ The rptrOperStatus object must be included in the
3494
+ varbind list sent with this trap. The agent may
3495
+ optionally include the rptrHealthText object as
3496
+ well.""",
3497
+ "reference" :
3498
+ """[IEEE 802.3 Mgt], 30.4.1.3.2, nRepeaterReset
3499
+ notification.""",
3500
+ }, # notification
3501
+ "rptrInfoHealth" : {
3502
+ "nodetype" : "notification",
3503
+ "moduleName" : "SNMP-REPEATER-MIB",
3504
+ "oid" : "1.3.6.1.2.1.22.0.4",
3505
+ "status" : "current",
3506
+ "objects" : {
3507
+ "rptrInfoOperStatus" : {
3508
+ "nodetype" : "object",
3509
+ "module" : "SNMP-REPEATER-MIB"
3510
+ },
3511
+ },
3512
+ "description" :
3513
+ """In a system containing multiple managed repeaters,
3514
+ the rptrInfoHealth notification conveys information
3515
+ related to the operational status of a repeater.
3516
+ It is sent either when the value of rptrInfoOperStatus
3517
+ changes, or upon completion of a non-disruptive test.
3518
+
3519
+ The agent must throttle the generation of
3520
+ consecutive rptrInfoHealth notifications for
3521
+ the same repeater so that there is at least
3522
+ a five-second gap between notifications of this type.
3523
+ When notifications are throttled, they are dropped,
3524
+ not queued for sending at a future time. (Note
3525
+ that 'generating' a notification means sending
3526
+ to all configured recipients.)""",
3527
+ "reference" :
3528
+ """[IEEE 802.3 Mgt], 30.4.1.3.1, nRepeaterHealth
3529
+ notification.""",
3530
+ }, # notification
3531
+ "rptrInfoResetEvent" : {
3532
+ "nodetype" : "notification",
3533
+ "moduleName" : "SNMP-REPEATER-MIB",
3534
+ "oid" : "1.3.6.1.2.1.22.0.5",
3535
+ "status" : "current",
3536
+ "objects" : {
3537
+ "rptrInfoOperStatus" : {
3538
+ "nodetype" : "object",
3539
+ "module" : "SNMP-REPEATER-MIB"
3540
+ },
3541
+ },
3542
+ "description" :
3543
+ """In a system containing multiple managed
3544
+ repeaters, the rptrInfoResetEvent notification
3545
+ conveys information related to the operational
3546
+ status of a repeater. This notification is sent
3547
+ on completion of a repeater reset action. A
3548
+ repeater reset action is defined as a transition
3549
+ to the START state of Fig 9-2 in section 9 of
3550
+ [IEEE 802.3 Std], when triggered by a management
3551
+ command (e.g., an SNMP Set on the rptrInfoReset
3552
+ object).
3553
+
3554
+ The agent must throttle the generation of
3555
+ consecutive rptrInfoResetEvent notifications for
3556
+ a single repeater so that there is at least
3557
+ a five-second gap between notifications of
3558
+ this type. When notifications are throttled,
3559
+ they are dropped, not queued for sending at
3560
+ a future time. (Note that 'generating' a
3561
+ notification means sending to all configured
3562
+ recipients.)
3563
+
3564
+ The rptrInfoResetEvent is not sent when the
3565
+ agent restarts and sends an SNMP coldStart or
3566
+ warmStart trap. However, it is recommended that
3567
+ a repeater agent send the rptrInfoOperStatus
3568
+ object as an optional object with its coldStart
3569
+ and warmStart trap PDUs.""",
3570
+ "reference" :
3571
+ """[IEEE 802.3 Mgt], 30.4.1.3.2, nRepeaterReset
3572
+ notification.""",
3573
+ }, # notification
3574
+ }, # notifications
3575
+
3576
+ "groups" : {
3577
+ "snmpRptrGrpBasic1516" : {
3578
+ "nodetype" : "group",
3579
+ "moduleName" : "SNMP-REPEATER-MIB",
3580
+ "oid" : "1.3.6.1.2.1.22.5.1.2.1",
3581
+ "status" : "deprecated",
3582
+ "members" : {
3583
+ "rptrGroupCapacity" : {
3584
+ "nodetype" : "member",
3585
+ "module" : "SNMP-REPEATER-MIB"
3586
+ },
3587
+ "rptrOperStatus" : {
3588
+ "nodetype" : "member",
3589
+ "module" : "SNMP-REPEATER-MIB"
3590
+ },
3591
+ "rptrHealthText" : {
3592
+ "nodetype" : "member",
3593
+ "module" : "SNMP-REPEATER-MIB"
3594
+ },
3595
+ "rptrReset" : {
3596
+ "nodetype" : "member",
3597
+ "module" : "SNMP-REPEATER-MIB"
3598
+ },
3599
+ "rptrNonDisruptTest" : {
3600
+ "nodetype" : "member",
3601
+ "module" : "SNMP-REPEATER-MIB"
3602
+ },
3603
+ "rptrTotalPartitionedPorts" : {
3604
+ "nodetype" : "member",
3605
+ "module" : "SNMP-REPEATER-MIB"
3606
+ },
3607
+ "rptrGroupIndex" : {
3608
+ "nodetype" : "member",
3609
+ "module" : "SNMP-REPEATER-MIB"
3610
+ },
3611
+ "rptrGroupDescr" : {
3612
+ "nodetype" : "member",
3613
+ "module" : "SNMP-REPEATER-MIB"
3614
+ },
3615
+ "rptrGroupObjectID" : {
3616
+ "nodetype" : "member",
3617
+ "module" : "SNMP-REPEATER-MIB"
3618
+ },
3619
+ "rptrGroupOperStatus" : {
3620
+ "nodetype" : "member",
3621
+ "module" : "SNMP-REPEATER-MIB"
3622
+ },
3623
+ "rptrGroupLastOperStatusChange" : {
3624
+ "nodetype" : "member",
3625
+ "module" : "SNMP-REPEATER-MIB"
3626
+ },
3627
+ "rptrGroupPortCapacity" : {
3628
+ "nodetype" : "member",
3629
+ "module" : "SNMP-REPEATER-MIB"
3630
+ },
3631
+ "rptrPortGroupIndex" : {
3632
+ "nodetype" : "member",
3633
+ "module" : "SNMP-REPEATER-MIB"
3634
+ },
3635
+ "rptrPortIndex" : {
3636
+ "nodetype" : "member",
3637
+ "module" : "SNMP-REPEATER-MIB"
3638
+ },
3639
+ "rptrPortAdminStatus" : {
3640
+ "nodetype" : "member",
3641
+ "module" : "SNMP-REPEATER-MIB"
3642
+ },
3643
+ "rptrPortAutoPartitionState" : {
3644
+ "nodetype" : "member",
3645
+ "module" : "SNMP-REPEATER-MIB"
3646
+ },
3647
+ "rptrPortOperStatus" : {
3648
+ "nodetype" : "member",
3649
+ "module" : "SNMP-REPEATER-MIB"
3650
+ },
3651
+ }, # members
3652
+ "description" :
3653
+ """********* THIS GROUP IS DEPRECATED **********
3654
+
3655
+ Basic group from RFCs 1368 and 1516.
3656
+
3657
+ NOTE: this object group is DEPRECATED and replaced
3658
+ with snmpRptrGrpBasic.""",
3659
+ }, # group
3660
+ "snmpRptrGrpMonitor1516" : {
3661
+ "nodetype" : "group",
3662
+ "moduleName" : "SNMP-REPEATER-MIB",
3663
+ "oid" : "1.3.6.1.2.1.22.5.1.2.2",
3664
+ "status" : "deprecated",
3665
+ "members" : {
3666
+ "rptrMonitorTransmitCollisions" : {
3667
+ "nodetype" : "member",
3668
+ "module" : "SNMP-REPEATER-MIB"
3669
+ },
3670
+ "rptrMonitorGroupIndex" : {
3671
+ "nodetype" : "member",
3672
+ "module" : "SNMP-REPEATER-MIB"
3673
+ },
3674
+ "rptrMonitorGroupTotalFrames" : {
3675
+ "nodetype" : "member",
3676
+ "module" : "SNMP-REPEATER-MIB"
3677
+ },
3678
+ "rptrMonitorGroupTotalOctets" : {
3679
+ "nodetype" : "member",
3680
+ "module" : "SNMP-REPEATER-MIB"
3681
+ },
3682
+ "rptrMonitorGroupTotalErrors" : {
3683
+ "nodetype" : "member",
3684
+ "module" : "SNMP-REPEATER-MIB"
3685
+ },
3686
+ "rptrMonitorPortGroupIndex" : {
3687
+ "nodetype" : "member",
3688
+ "module" : "SNMP-REPEATER-MIB"
3689
+ },
3690
+ "rptrMonitorPortIndex" : {
3691
+ "nodetype" : "member",
3692
+ "module" : "SNMP-REPEATER-MIB"
3693
+ },
3694
+ "rptrMonitorPortReadableFrames" : {
3695
+ "nodetype" : "member",
3696
+ "module" : "SNMP-REPEATER-MIB"
3697
+ },
3698
+ "rptrMonitorPortReadableOctets" : {
3699
+ "nodetype" : "member",
3700
+ "module" : "SNMP-REPEATER-MIB"
3701
+ },
3702
+ "rptrMonitorPortFCSErrors" : {
3703
+ "nodetype" : "member",
3704
+ "module" : "SNMP-REPEATER-MIB"
3705
+ },
3706
+ "rptrMonitorPortAlignmentErrors" : {
3707
+ "nodetype" : "member",
3708
+ "module" : "SNMP-REPEATER-MIB"
3709
+ },
3710
+ "rptrMonitorPortFrameTooLongs" : {
3711
+ "nodetype" : "member",
3712
+ "module" : "SNMP-REPEATER-MIB"
3713
+ },
3714
+ "rptrMonitorPortShortEvents" : {
3715
+ "nodetype" : "member",
3716
+ "module" : "SNMP-REPEATER-MIB"
3717
+ },
3718
+ "rptrMonitorPortRunts" : {
3719
+ "nodetype" : "member",
3720
+ "module" : "SNMP-REPEATER-MIB"
3721
+ },
3722
+ "rptrMonitorPortCollisions" : {
3723
+ "nodetype" : "member",
3724
+ "module" : "SNMP-REPEATER-MIB"
3725
+ },
3726
+ "rptrMonitorPortLateEvents" : {
3727
+ "nodetype" : "member",
3728
+ "module" : "SNMP-REPEATER-MIB"
3729
+ },
3730
+ "rptrMonitorPortVeryLongEvents" : {
3731
+ "nodetype" : "member",
3732
+ "module" : "SNMP-REPEATER-MIB"
3733
+ },
3734
+ "rptrMonitorPortDataRateMismatches" : {
3735
+ "nodetype" : "member",
3736
+ "module" : "SNMP-REPEATER-MIB"
3737
+ },
3738
+ "rptrMonitorPortAutoPartitions" : {
3739
+ "nodetype" : "member",
3740
+ "module" : "SNMP-REPEATER-MIB"
3741
+ },
3742
+ "rptrMonitorPortTotalErrors" : {
3743
+ "nodetype" : "member",
3744
+ "module" : "SNMP-REPEATER-MIB"
3745
+ },
3746
+ }, # members
3747
+ "description" :
3748
+ """********* THIS GROUP IS DEPRECATED **********
3749
+
3750
+ Monitor group from RFCs 1368 and 1516.
3751
+
3752
+ NOTE: this object group is DEPRECATED and replaced
3753
+ with snmpRptrGrpMonitor.""",
3754
+ }, # group
3755
+ "snmpRptrGrpAddrTrack1368" : {
3756
+ "nodetype" : "group",
3757
+ "moduleName" : "SNMP-REPEATER-MIB",
3758
+ "oid" : "1.3.6.1.2.1.22.5.1.2.3",
3759
+ "status" : "obsolete",
3760
+ "members" : {
3761
+ "rptrAddrTrackGroupIndex" : {
3762
+ "nodetype" : "member",
3763
+ "module" : "SNMP-REPEATER-MIB"
3764
+ },
3765
+ "rptrAddrTrackPortIndex" : {
3766
+ "nodetype" : "member",
3767
+ "module" : "SNMP-REPEATER-MIB"
3768
+ },
3769
+ "rptrAddrTrackLastSourceAddress" : {
3770
+ "nodetype" : "member",
3771
+ "module" : "SNMP-REPEATER-MIB"
3772
+ },
3773
+ "rptrAddrTrackSourceAddrChanges" : {
3774
+ "nodetype" : "member",
3775
+ "module" : "SNMP-REPEATER-MIB"
3776
+ },
3777
+ }, # members
3778
+ "description" :
3779
+ """Address tracking group from RFC 1368.
3780
+
3781
+ NOTE: this object group is OBSOLETE and replaced
3782
+ with snmpRptrGrpAddrTrack1516.""",
3783
+ }, # group
3784
+ "snmpRptrGrpAddrTrack1516" : {
3785
+ "nodetype" : "group",
3786
+ "moduleName" : "SNMP-REPEATER-MIB",
3787
+ "oid" : "1.3.6.1.2.1.22.5.1.2.4",
3788
+ "status" : "deprecated",
3789
+ "members" : {
3790
+ "rptrAddrTrackGroupIndex" : {
3791
+ "nodetype" : "member",
3792
+ "module" : "SNMP-REPEATER-MIB"
3793
+ },
3794
+ "rptrAddrTrackPortIndex" : {
3795
+ "nodetype" : "member",
3796
+ "module" : "SNMP-REPEATER-MIB"
3797
+ },
3798
+ "rptrAddrTrackLastSourceAddress" : {
3799
+ "nodetype" : "member",
3800
+ "module" : "SNMP-REPEATER-MIB"
3801
+ },
3802
+ "rptrAddrTrackSourceAddrChanges" : {
3803
+ "nodetype" : "member",
3804
+ "module" : "SNMP-REPEATER-MIB"
3805
+ },
3806
+ "rptrAddrTrackNewLastSrcAddress" : {
3807
+ "nodetype" : "member",
3808
+ "module" : "SNMP-REPEATER-MIB"
3809
+ },
3810
+ }, # members
3811
+ "description" :
3812
+ """********* THIS GROUP IS DEPRECATED **********
3813
+ Address tracking group from RFC 1516.
3814
+
3815
+ NOTE: this object group is DEPRECATED and
3816
+ replaced with snmpRptrGrpAddrTrack.""",
3817
+ }, # group
3818
+ "snmpRptrGrpBasic" : {
3819
+ "nodetype" : "group",
3820
+ "moduleName" : "SNMP-REPEATER-MIB",
3821
+ "oid" : "1.3.6.1.2.1.22.5.1.2.5",
3822
+ "status" : "current",
3823
+ "members" : {
3824
+ "rptrGroupIndex" : {
3825
+ "nodetype" : "member",
3826
+ "module" : "SNMP-REPEATER-MIB"
3827
+ },
3828
+ "rptrGroupObjectID" : {
3829
+ "nodetype" : "member",
3830
+ "module" : "SNMP-REPEATER-MIB"
3831
+ },
3832
+ "rptrGroupOperStatus" : {
3833
+ "nodetype" : "member",
3834
+ "module" : "SNMP-REPEATER-MIB"
3835
+ },
3836
+ "rptrGroupPortCapacity" : {
3837
+ "nodetype" : "member",
3838
+ "module" : "SNMP-REPEATER-MIB"
3839
+ },
3840
+ "rptrPortGroupIndex" : {
3841
+ "nodetype" : "member",
3842
+ "module" : "SNMP-REPEATER-MIB"
3843
+ },
3844
+ "rptrPortIndex" : {
3845
+ "nodetype" : "member",
3846
+ "module" : "SNMP-REPEATER-MIB"
3847
+ },
3848
+ "rptrPortAdminStatus" : {
3849
+ "nodetype" : "member",
3850
+ "module" : "SNMP-REPEATER-MIB"
3851
+ },
3852
+ "rptrPortAutoPartitionState" : {
3853
+ "nodetype" : "member",
3854
+ "module" : "SNMP-REPEATER-MIB"
3855
+ },
3856
+ "rptrPortOperStatus" : {
3857
+ "nodetype" : "member",
3858
+ "module" : "SNMP-REPEATER-MIB"
3859
+ },
3860
+ "rptrPortRptrId" : {
3861
+ "nodetype" : "member",
3862
+ "module" : "SNMP-REPEATER-MIB"
3863
+ },
3864
+ "rptrInfoId" : {
3865
+ "nodetype" : "member",
3866
+ "module" : "SNMP-REPEATER-MIB"
3867
+ },
3868
+ "rptrInfoRptrType" : {
3869
+ "nodetype" : "member",
3870
+ "module" : "SNMP-REPEATER-MIB"
3871
+ },
3872
+ "rptrInfoOperStatus" : {
3873
+ "nodetype" : "member",
3874
+ "module" : "SNMP-REPEATER-MIB"
3875
+ },
3876
+ "rptrInfoReset" : {
3877
+ "nodetype" : "member",
3878
+ "module" : "SNMP-REPEATER-MIB"
3879
+ },
3880
+ "rptrInfoPartitionedPorts" : {
3881
+ "nodetype" : "member",
3882
+ "module" : "SNMP-REPEATER-MIB"
3883
+ },
3884
+ "rptrInfoLastChange" : {
3885
+ "nodetype" : "member",
3886
+ "module" : "SNMP-REPEATER-MIB"
3887
+ },
3888
+ }, # members
3889
+ "description" :
3890
+ """Basic group for a system with one or more
3891
+ repeater-units in multi-segment (post-RFC 1516)
3892
+ version of the MIB module.""",
3893
+ }, # group
3894
+ "snmpRptrGrpMonitor" : {
3895
+ "nodetype" : "group",
3896
+ "moduleName" : "SNMP-REPEATER-MIB",
3897
+ "oid" : "1.3.6.1.2.1.22.5.1.2.6",
3898
+ "status" : "current",
3899
+ "members" : {
3900
+ "rptrMonitorPortGroupIndex" : {
3901
+ "nodetype" : "member",
3902
+ "module" : "SNMP-REPEATER-MIB"
3903
+ },
3904
+ "rptrMonitorPortIndex" : {
3905
+ "nodetype" : "member",
3906
+ "module" : "SNMP-REPEATER-MIB"
3907
+ },
3908
+ "rptrMonitorPortReadableFrames" : {
3909
+ "nodetype" : "member",
3910
+ "module" : "SNMP-REPEATER-MIB"
3911
+ },
3912
+ "rptrMonitorPortReadableOctets" : {
3913
+ "nodetype" : "member",
3914
+ "module" : "SNMP-REPEATER-MIB"
3915
+ },
3916
+ "rptrMonitorPortFCSErrors" : {
3917
+ "nodetype" : "member",
3918
+ "module" : "SNMP-REPEATER-MIB"
3919
+ },
3920
+ "rptrMonitorPortAlignmentErrors" : {
3921
+ "nodetype" : "member",
3922
+ "module" : "SNMP-REPEATER-MIB"
3923
+ },
3924
+ "rptrMonitorPortFrameTooLongs" : {
3925
+ "nodetype" : "member",
3926
+ "module" : "SNMP-REPEATER-MIB"
3927
+ },
3928
+ "rptrMonitorPortShortEvents" : {
3929
+ "nodetype" : "member",
3930
+ "module" : "SNMP-REPEATER-MIB"
3931
+ },
3932
+ "rptrMonitorPortRunts" : {
3933
+ "nodetype" : "member",
3934
+ "module" : "SNMP-REPEATER-MIB"
3935
+ },
3936
+ "rptrMonitorPortCollisions" : {
3937
+ "nodetype" : "member",
3938
+ "module" : "SNMP-REPEATER-MIB"
3939
+ },
3940
+ "rptrMonitorPortLateEvents" : {
3941
+ "nodetype" : "member",
3942
+ "module" : "SNMP-REPEATER-MIB"
3943
+ },
3944
+ "rptrMonitorPortVeryLongEvents" : {
3945
+ "nodetype" : "member",
3946
+ "module" : "SNMP-REPEATER-MIB"
3947
+ },
3948
+ "rptrMonitorPortDataRateMismatches" : {
3949
+ "nodetype" : "member",
3950
+ "module" : "SNMP-REPEATER-MIB"
3951
+ },
3952
+ "rptrMonitorPortAutoPartitions" : {
3953
+ "nodetype" : "member",
3954
+ "module" : "SNMP-REPEATER-MIB"
3955
+ },
3956
+ "rptrMonitorPortTotalErrors" : {
3957
+ "nodetype" : "member",
3958
+ "module" : "SNMP-REPEATER-MIB"
3959
+ },
3960
+ "rptrMonitorPortLastChange" : {
3961
+ "nodetype" : "member",
3962
+ "module" : "SNMP-REPEATER-MIB"
3963
+ },
3964
+ "rptrMonTxCollisions" : {
3965
+ "nodetype" : "member",
3966
+ "module" : "SNMP-REPEATER-MIB"
3967
+ },
3968
+ "rptrMonTotalFrames" : {
3969
+ "nodetype" : "member",
3970
+ "module" : "SNMP-REPEATER-MIB"
3971
+ },
3972
+ "rptrMonTotalErrors" : {
3973
+ "nodetype" : "member",
3974
+ "module" : "SNMP-REPEATER-MIB"
3975
+ },
3976
+ "rptrMonTotalOctets" : {
3977
+ "nodetype" : "member",
3978
+ "module" : "SNMP-REPEATER-MIB"
3979
+ },
3980
+ }, # members
3981
+ "description" :
3982
+ """Monitor group for a system with one or more
3983
+ repeater-units in multi-segment (post-RFC 1516)
3984
+ version of the MIB module.""",
3985
+ }, # group
3986
+ "snmpRptrGrpMonitor100" : {
3987
+ "nodetype" : "group",
3988
+ "moduleName" : "SNMP-REPEATER-MIB",
3989
+ "oid" : "1.3.6.1.2.1.22.5.1.2.7",
3990
+ "status" : "current",
3991
+ "members" : {
3992
+ "rptrMonitorPortIsolates" : {
3993
+ "nodetype" : "member",
3994
+ "module" : "SNMP-REPEATER-MIB"
3995
+ },
3996
+ "rptrMonitorPortSymbolErrors" : {
3997
+ "nodetype" : "member",
3998
+ "module" : "SNMP-REPEATER-MIB"
3999
+ },
4000
+ "rptrMonitorPortUpper32Octets" : {
4001
+ "nodetype" : "member",
4002
+ "module" : "SNMP-REPEATER-MIB"
4003
+ },
4004
+ "rptrMonUpper32TotalOctets" : {
4005
+ "nodetype" : "member",
4006
+ "module" : "SNMP-REPEATER-MIB"
4007
+ },
4008
+ }, # members
4009
+ "description" :
4010
+ """Monitor group for 100Mb/s ports and repeaters
4011
+ in a system with one or more repeater-units in
4012
+ multi-segment (post-RFC 1516) version of the MIB
4013
+ module. Systems which support Counter64 should
4014
+ also implement snmpRptrGrpMonitor100w64.""",
4015
+ }, # group
4016
+ "snmpRptrGrpMonitor100w64" : {
4017
+ "nodetype" : "group",
4018
+ "moduleName" : "SNMP-REPEATER-MIB",
4019
+ "oid" : "1.3.6.1.2.1.22.5.1.2.8",
4020
+ "status" : "current",
4021
+ "members" : {
4022
+ "rptrMonitorPortHCReadableOctets" : {
4023
+ "nodetype" : "member",
4024
+ "module" : "SNMP-REPEATER-MIB"
4025
+ },
4026
+ "rptrMonHCTotalOctets" : {
4027
+ "nodetype" : "member",
4028
+ "module" : "SNMP-REPEATER-MIB"
4029
+ },
4030
+ }, # members
4031
+ "description" :
4032
+ """Monitor group for 100Mb/s ports and repeaters in a
4033
+ system with one or more repeater-units and support
4034
+ for Counter64.""",
4035
+ }, # group
4036
+ "snmpRptrGrpAddrTrack" : {
4037
+ "nodetype" : "group",
4038
+ "moduleName" : "SNMP-REPEATER-MIB",
4039
+ "oid" : "1.3.6.1.2.1.22.5.1.2.9",
4040
+ "status" : "current",
4041
+ "members" : {
4042
+ "rptrAddrTrackGroupIndex" : {
4043
+ "nodetype" : "member",
4044
+ "module" : "SNMP-REPEATER-MIB"
4045
+ },
4046
+ "rptrAddrTrackPortIndex" : {
4047
+ "nodetype" : "member",
4048
+ "module" : "SNMP-REPEATER-MIB"
4049
+ },
4050
+ "rptrAddrTrackSourceAddrChanges" : {
4051
+ "nodetype" : "member",
4052
+ "module" : "SNMP-REPEATER-MIB"
4053
+ },
4054
+ "rptrAddrTrackNewLastSrcAddress" : {
4055
+ "nodetype" : "member",
4056
+ "module" : "SNMP-REPEATER-MIB"
4057
+ },
4058
+ "rptrAddrTrackCapacity" : {
4059
+ "nodetype" : "member",
4060
+ "module" : "SNMP-REPEATER-MIB"
4061
+ },
4062
+ }, # members
4063
+ "description" :
4064
+ """Passive address tracking group for post-RFC 1516
4065
+ version of the MIB module.""",
4066
+ }, # group
4067
+ "snmpRptrGrpExtAddrTrack" : {
4068
+ "nodetype" : "group",
4069
+ "moduleName" : "SNMP-REPEATER-MIB",
4070
+ "oid" : "1.3.6.1.2.1.22.5.1.2.10",
4071
+ "status" : "current",
4072
+ "members" : {
4073
+ "rptrExtAddrTrackMacIndex" : {
4074
+ "nodetype" : "member",
4075
+ "module" : "SNMP-REPEATER-MIB"
4076
+ },
4077
+ "rptrExtAddrTrackSourceAddress" : {
4078
+ "nodetype" : "member",
4079
+ "module" : "SNMP-REPEATER-MIB"
4080
+ },
4081
+ }, # members
4082
+ "description" :
4083
+ """Extended passive address tracking group for
4084
+ a system with one or more repeater-units in
4085
+ post-RFC 1516 version of the MIB module.""",
4086
+ }, # group
4087
+ "snmpRptrGrpRptrAddrSearch" : {
4088
+ "nodetype" : "group",
4089
+ "moduleName" : "SNMP-REPEATER-MIB",
4090
+ "oid" : "1.3.6.1.2.1.22.5.1.2.11",
4091
+ "status" : "current",
4092
+ "members" : {
4093
+ "rptrAddrSearchLock" : {
4094
+ "nodetype" : "member",
4095
+ "module" : "SNMP-REPEATER-MIB"
4096
+ },
4097
+ "rptrAddrSearchStatus" : {
4098
+ "nodetype" : "member",
4099
+ "module" : "SNMP-REPEATER-MIB"
4100
+ },
4101
+ "rptrAddrSearchAddress" : {
4102
+ "nodetype" : "member",
4103
+ "module" : "SNMP-REPEATER-MIB"
4104
+ },
4105
+ "rptrAddrSearchState" : {
4106
+ "nodetype" : "member",
4107
+ "module" : "SNMP-REPEATER-MIB"
4108
+ },
4109
+ "rptrAddrSearchGroup" : {
4110
+ "nodetype" : "member",
4111
+ "module" : "SNMP-REPEATER-MIB"
4112
+ },
4113
+ "rptrAddrSearchPort" : {
4114
+ "nodetype" : "member",
4115
+ "module" : "SNMP-REPEATER-MIB"
4116
+ },
4117
+ "rptrAddrSearchOwner" : {
4118
+ "nodetype" : "member",
4119
+ "module" : "SNMP-REPEATER-MIB"
4120
+ },
4121
+ }, # members
4122
+ "description" :
4123
+ """Active MAC address search group and topology
4124
+ mapping support for repeaters.""",
4125
+ }, # group
4126
+ "snmpRptrGrpTopNPort" : {
4127
+ "nodetype" : "group",
4128
+ "moduleName" : "SNMP-REPEATER-MIB",
4129
+ "oid" : "1.3.6.1.2.1.22.5.1.2.12",
4130
+ "status" : "current",
4131
+ "members" : {
4132
+ "rptrTopNPortControlIndex" : {
4133
+ "nodetype" : "member",
4134
+ "module" : "SNMP-REPEATER-MIB"
4135
+ },
4136
+ "rptrTopNPortRepeaterId" : {
4137
+ "nodetype" : "member",
4138
+ "module" : "SNMP-REPEATER-MIB"
4139
+ },
4140
+ "rptrTopNPortRateBase" : {
4141
+ "nodetype" : "member",
4142
+ "module" : "SNMP-REPEATER-MIB"
4143
+ },
4144
+ "rptrTopNPortTimeRemaining" : {
4145
+ "nodetype" : "member",
4146
+ "module" : "SNMP-REPEATER-MIB"
4147
+ },
4148
+ "rptrTopNPortDuration" : {
4149
+ "nodetype" : "member",
4150
+ "module" : "SNMP-REPEATER-MIB"
4151
+ },
4152
+ "rptrTopNPortRequestedSize" : {
4153
+ "nodetype" : "member",
4154
+ "module" : "SNMP-REPEATER-MIB"
4155
+ },
4156
+ "rptrTopNPortGrantedSize" : {
4157
+ "nodetype" : "member",
4158
+ "module" : "SNMP-REPEATER-MIB"
4159
+ },
4160
+ "rptrTopNPortStartTime" : {
4161
+ "nodetype" : "member",
4162
+ "module" : "SNMP-REPEATER-MIB"
4163
+ },
4164
+ "rptrTopNPortOwner" : {
4165
+ "nodetype" : "member",
4166
+ "module" : "SNMP-REPEATER-MIB"
4167
+ },
4168
+ "rptrTopNPortRowStatus" : {
4169
+ "nodetype" : "member",
4170
+ "module" : "SNMP-REPEATER-MIB"
4171
+ },
4172
+ "rptrTopNPortIndex" : {
4173
+ "nodetype" : "member",
4174
+ "module" : "SNMP-REPEATER-MIB"
4175
+ },
4176
+ "rptrTopNPortGroupIndex" : {
4177
+ "nodetype" : "member",
4178
+ "module" : "SNMP-REPEATER-MIB"
4179
+ },
4180
+ "rptrTopNPortPortIndex" : {
4181
+ "nodetype" : "member",
4182
+ "module" : "SNMP-REPEATER-MIB"
4183
+ },
4184
+ "rptrTopNPortRate" : {
4185
+ "nodetype" : "member",
4186
+ "module" : "SNMP-REPEATER-MIB"
4187
+ },
4188
+ }, # members
4189
+ "description" :
4190
+ """Top `N' group for repeater ports.""",
4191
+ }, # group
4192
+ }, # groups
4193
+
4194
+ "compliances" : {
4195
+ "snmpRptrModComplRFC1368" : {
4196
+ "nodetype" : "compliance",
4197
+ "moduleName" : "SNMP-REPEATER-MIB",
4198
+ "oid" : "1.3.6.1.2.1.22.5.1.1.1",
4199
+ "status" : "obsolete",
4200
+ "description" :
4201
+ """Compliance for RFC 1368.
4202
+
4203
+ NOTE: this module compliance is OBSOLETE and
4204
+ replaced by snmpRptrModComplRFC1516.""",
4205
+ "requires" : {
4206
+ "snmpRptrGrpBasic1516" : {
4207
+ "nodetype" : "mandatory",
4208
+ "module" : "SNMP-REPEATER-MIB"
4209
+ },
4210
+ "snmpRptrGrpMonitor1516" : {
4211
+ "nodetype" : "optional",
4212
+ "module" : "SNMP-REPEATER-MIB",
4213
+ "description" :
4214
+ """Implementation of this optional group is
4215
+ recommended for systems which have the
4216
+ instrumentation to do performance monitoring.""",
4217
+ },
4218
+ "snmpRptrGrpAddrTrack1368" : {
4219
+ "nodetype" : "optional",
4220
+ "module" : "SNMP-REPEATER-MIB",
4221
+ "description" :
4222
+ """Implementation of this group is
4223
+ recommended for systems which have
4224
+ the necessary instrumentation.""",
4225
+ },
4226
+ }, # requires
4227
+ }, # compliance
4228
+ "snmpRptrModComplRFC1516" : {
4229
+ "nodetype" : "compliance",
4230
+ "moduleName" : "SNMP-REPEATER-MIB",
4231
+ "oid" : "1.3.6.1.2.1.22.5.1.1.2",
4232
+ "status" : "deprecated",
4233
+ "description" :
4234
+ """********* THIS COMPLIANCE IS DEPRECATED **********
4235
+
4236
+ Compliance for RFC 1516 and for backwards
4237
+ compatibility with single-repeater,
4238
+ 10Mb/s-only implementations.""",
4239
+ "requires" : {
4240
+ "snmpRptrGrpBasic1516" : {
4241
+ "nodetype" : "mandatory",
4242
+ "module" : "SNMP-REPEATER-MIB"
4243
+ },
4244
+ "snmpRptrGrpMonitor1516" : {
4245
+ "nodetype" : "optional",
4246
+ "module" : "SNMP-REPEATER-MIB",
4247
+ "description" :
4248
+ """Implementation of this optional group is
4249
+ recommended for systems which have the
4250
+ instrumentation to do performance monitoring.""",
4251
+ },
4252
+ "snmpRptrGrpAddrTrack1516" : {
4253
+ "nodetype" : "optional",
4254
+ "module" : "SNMP-REPEATER-MIB",
4255
+ "description" :
4256
+ """Implementation of this group is
4257
+ recommended for systems which have
4258
+ the necessary instrumentation.""",
4259
+ },
4260
+ }, # requires
4261
+ }, # compliance
4262
+ "snmpRptrModCompl" : {
4263
+ "nodetype" : "compliance",
4264
+ "moduleName" : "SNMP-REPEATER-MIB",
4265
+ "oid" : "1.3.6.1.2.1.22.5.1.1.3",
4266
+ "status" : "current",
4267
+ "description" :
4268
+ """Compliance for the multi-segment version of the
4269
+ MIB module for a system with one or more
4270
+ repeater-units.""",
4271
+ "requires" : {
4272
+ "snmpRptrGrpBasic" : {
4273
+ "nodetype" : "mandatory",
4274
+ "module" : "SNMP-REPEATER-MIB"
4275
+ },
4276
+ "snmpRptrGrpMonitor" : {
4277
+ "nodetype" : "mandatory",
4278
+ "module" : "SNMP-REPEATER-MIB"
4279
+ },
4280
+ "snmpRptrGrpAddrTrack" : {
4281
+ "nodetype" : "mandatory",
4282
+ "module" : "SNMP-REPEATER-MIB"
4283
+ },
4284
+ "snmpRptrGrpMonitor100" : {
4285
+ "nodetype" : "optional",
4286
+ "module" : "SNMP-REPEATER-MIB",
4287
+ "description" :
4288
+ """Implementation of this group is
4289
+ mandatory for managed systems which
4290
+ contain 100Mb/s repeaters.""",
4291
+ },
4292
+ "snmpRptrGrpMonitor100w64" : {
4293
+ "nodetype" : "optional",
4294
+ "module" : "SNMP-REPEATER-MIB",
4295
+ "description" :
4296
+ """Implementation of this group is
4297
+ mandatory for managed systems which
4298
+ contain 100Mb/s repeaters and which
4299
+ can support Counter64.""",
4300
+ },
4301
+ "snmpRptrGrpExtAddrTrack" : {
4302
+ "nodetype" : "optional",
4303
+ "module" : "SNMP-REPEATER-MIB",
4304
+ "description" :
4305
+ """Implementation of this group is
4306
+ recommended for systems which have
4307
+ the necessary instrumentation to track
4308
+ MAC addresses of multiple DTEs attached
4309
+ to a single repeater port.""",
4310
+ },
4311
+ "snmpRptrGrpRptrAddrSearch" : {
4312
+ "nodetype" : "optional",
4313
+ "module" : "SNMP-REPEATER-MIB",
4314
+ "description" :
4315
+ """Implementation of this group is
4316
+ recommended for systems which allow
4317
+ read-write access and which have
4318
+ the necessary instrumentation to
4319
+ search all incoming data streams
4320
+ for a particular MAC address.""",
4321
+ },
4322
+ "snmpRptrGrpTopNPort" : {
4323
+ "nodetype" : "optional",
4324
+ "module" : "SNMP-REPEATER-MIB",
4325
+ "description" :
4326
+ """Implementation of this group is
4327
+ recommended for systems which have
4328
+ the necessary resources to support
4329
+ TopN statistics reporting.""",
4330
+ },
4331
+ }, # requires
4332
+ }, # compliance
4333
+ }, # compliances
4334
+
4335
+ }